WNERS MANUAL
M
ODEL
F
515
R ‐U
© 2014 ASI Doors, Inc.
1-800-558-7068
Manual Part Number: 17B066-062314
www.asidoors.com
Page 2 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Safety Practices
General Information
515 Roll-Up
This is the safety alert symbol. It is used to alert you to potential personal safety hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates an potentially hazardous situation which, if not avoided, will result in minor or moderate injury.
CAUTION used without the safety alert symbol, indicates an potentially hazardous situation which, if not avoided, may result in property damage.
NOTE explains general information.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 3
1-800-558-7068
General Information
515 Roll-Up
Safety Practices
Continued...
Please read the safety practices and the manual thoroughly before connecting power to the control box.
1. Do not operate the door while under the influence of drugs or alcohol.
2. Do not use the door if it looks broken or does not seem to work right. Advise your supervisor at once.
3. Stay clear of the door when it is moving.
4. Keep hands, feet and head clear of the door at all times.
5. Do not operate the door with equipment, material or people directly underneath the door.
6. Disconnect power before performing any electrical or mechanical service, cleaning or other maintenance on the door. OSHA requires disconnect to be properly tagged and locked out during all maintenance or service of equipment. With the power supply disconnected, always verify using a volt meter.
7. All electrical troubleshooting or service must be completed by a qualified electrician or service person and must meet all applicable local, state, federal, international and other governing agency codes.
8. When it is necessary to service the control box with power on, USE EXTREME CAUTION. Do not place fingers or un-insulated tools inside the control box. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death.
9. It is your responsibility to keep all warning labels and instructional literature legible, intact and kept with the door. Replacement labels and literature are available from ASI Doors, Inc. or its representatives.
10. If you have any questions contact your supervisor or your local ASI Doors, Inc. representative for assistance.
11. Failure to operate the door as intended, as described, or heed any warning may result in equipment damage, property damage, serious bodily injury or death.
Read these safety practices before installing, operating or servicing the door. Failure to follow These safety practices could result in property damage, serious bodily injury or death.
READ AND UNDERSTAND ALL WARNING LABELS AND OPERATING INSTRUCTIONS
IN THIS MANUAL BEFORE OPERATING THE DOOR. If you do not understand the instructions, ask your supervisor to teach you how to use the door.
Page 4 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
ASI Doors, Inc. Warranty Policy
General Information
515 Roll-Up
ASI Doors, Inc. (herein called "ASI") warrants solely for the benefit of its customer that each door system manufactured by ASI (each a "Door System") will be free from defects in material and manufacture for a period of one (1) year from the date of original shipment by ASI. The foregoing limited warranty shall not apply to defects which result from improper installation, abuse, misuse, alteration, modification or failure to maintain the Door System in accordance with the ASI Owner's Manual. Periodic lubrication and adjustment of the Door System as described in the
ASI Owner's Manual are the sole responsibility of the customer. All claims for defects must be made to ASI within thirty (30) days after the defect is discovered or should, with reasonable care, have been discovered. THE FOREGO-
ING LIMITED WARRANTY CONSTITUTES THE EXCLUSIVE WARRANTY OF ASI WITH RESPECT TO
THE DOOR SYSTEM. ASI EXPRESSLY DISCLAIMS ALL OTHER GUARANTEES OR WARRANTIES—
WHETHER EXPRESS, IMPLIED, OR STATUTORY—INCLUDING BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
If a Door System does not comply with the foregoing limited warranty, and a claim is made by customer within the applicable warranty period, ASI will, at the option of ASI, either repair or replace any defective equipment or parts free of charge, and pay the reasonable labor costs to repair or replace the defective equipment or parts. The remedy of repair or replacement shall be the exclusive and sole remedy for any breach of the foregoing limited warranty.
ASI SHALL NOT IN ANY EVENT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, EXEMPLA-
RY OR CONSEQUENTIAL DAMAGES OF ANY KIND, INCLUDING WITHOUT LIMITATION ANY LOST
PROFITS, ARISING FROM THE SALE OR USE OF THE DOOR SYSTEM, OR FROM ANY OTHER CAUSE
WHATSOEVER, WHETHER THE CLAIM GIVING RISE TO SUCH DAMAGES IS BASED UPON BREACH
OF WARRANTY (EXPRESSED OR IMPLIED) BREACH OF CONTRACT, TORT, STRICT LIABILITY OR
ANY OTHER THEORY OF LIABILITY, EVEN IF A PARTY HAS BEEN ADVISED OF THE POSSIBILITY
THEREOF, AND REGARDLESS OF ANY ADVISE OR REPRESENTATION THAT MAY HAVE BEEN REN-
DERED BY ASI CONCERNING THE SALE OR USE OF THE DOOR SYSTEM.
At ASI's request, customer shall return to ASI for inspection any Door System for which a warranty claim has been made, F.O.B. ASI's facility with freight prepaid. The customer is responsible for any removal costs.
The customer shall comply with the following procedures in filing a warranty claim with ASI:
1. Notify ASI of any and all defects in writing. ASI will review the warranty request and issue a Returns Goods
Authorization (RGA) form if the defective parts need to be returned to ASI for inspection and verification. The
RGA form must accompany any materials returned for warranty consideration.
2. All replacement parts or equipment will be invoiced to the customer. Upon verification by ASI that the Door
System is defective, ASI will issue a full credit to customer for the replacement parts or equipment.
3. If outside labor is needed to install the replacement parts or equipment, ASI requires a written estimate of the labor charges in advance so ASI may approve the labor charges and issue a purchase order. ASI will not accept any labor charges unless previously approved by ASI and accompanied by the ASI purchase order number.
The customer must file a claim with the shipper for any damage and/or losses that may occur during transit.
Installation hardware and start up of the Door System equipment is the responsibility of the installation contractor.
Periodic adjustments and normal maintenance are the responsibility of the customer.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 5
1-800-558-7068
General Information
515 Roll-Up
General Information
Table of Contents
Maintenance
Installation
Crates and Contents
Face Frame Installation
Warranty and Liability
Photoeye Connections
Final Checks and Verification
Setting Door Limits
Preventive Maintenance
Page 7
Replacement Parts
Page 10
Mechanical Service Parts List
11
Service Parts - Door Curtain
Service Parts - Motor Side
Page 18
Service Parts - Idler Side
Service Parts - Side Frames, &
Drive Assembly
Service Parts - Shrouds
Page 25
Page 28
Page 29
Electrical Service Parts List
Service Parts - Electrical
Instructions for Ordering
Page 40
Page 44
Page 46
Page 47
Page 48
Page 49
Page 50
Page 51
Page 52
Page 54
Wireless Detection Device
Photocell Install and Setup
Page 36
Page 37
Do not install, operate or service this product unless you have read and understand the Safety Practices, Warnings and Installation and Operating Instructions contained in this manual.
Failure to do so could result in property damage, bodily injury or death.
Page 6 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Crates and Contents
General Information
515 Roll-Up
SIDE
FRAMES
CRATE
HEADER AND
MOTOR ASSEMBLY
SHROUD ASSEMBLY
(OPTIONAL)
CONTROL BOX
LOOSE PARTS
BOX
CRATE
Figure 1: Crates and Contents.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 7
1-800-558-7068
General Information
515 Roll-Up
Crates and Contents
Continued...
Upon receipt of the shipment, check that you have received the correct number of pieces as shown
(Figure 1). Crate will contain the Side-Covers, the Header Assembly, the Loose Parts Box, and Control Box. For your protection, note any damages or shortages on the carrier’s bill of lading before signing the bill for receipt.
The installation of this door will require at least a two man crew and a fork-lift. Select a fork-lift with lifting height based upon the height of the door, plus a minimum additional two feet.
N O T E
Because of variances in the construction of walls on which the door will be mounted, fasteners are not supplied. For proper anchoring of the door, we recommend the use of thru-bolts.
DO NOT remove door sections from crate until you encounter the step in which they are to be installed.
L
OOSE
P
ARTS
B
OX
:
Installation Instructions ……………………….1
Sales Drawings ………………………………..1
Misc. Activation Devices ………….…… As Ordered
Owners Manual ………………………………..1
Warning Name Plate Assembly …...………...2
C
ONTROL
E
NCLOSURE
B
OX
:
Control Box …………………………………….1
6mm Hex Drive ……………………….….……1
Photo eyes …………..………………………...2
Schematic …...………………………………...1
Misc. Activation Devices ………….…… As Ordered
N O T E
Unless specifically called out as “Provided by ASI”, installer is to provide all necessary mounting hardware, anchors, inserts, hangers, supports and equipment needed to install door in accordance with final shop drawings and manufacturer’s instructions.
Page 8 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Door Measurements
Installation
515 Roll-Up
1. Make contact with the person responsible at the customer's place of business – check access conditions and prevailing safety practices.
2. First check the dimensions of the construction opening. The exact measurements can be found on the production sheet supplied with the door.
3. Carefully unpack the door and check the various components:
- Left and right side doorpost.
- Roll-up mechanism and installation manual included in the packing list.
- Control box, wiring diagram, photo eyes and cable for anti-roll off switch.
- Fasteners for the door, the operating controls and other accessories.
9”
Operator
21”
Header
17-1/2”
Drive Side
3”
1/2 WIC + 3”
Bolt Hole Locations
Figure 2: Door Measurements.
Tools Required
1 Tape measure
1 Water level
1 Pencil
1 General purpose pliers
1 A pair of wire cutters
1 Wire strippers
1 Digital Volt/Ohmmeter
1 Silicone caulk gun
1/2 WIC + 3”
Idler Side
3”
Figure 3: Marking Bolt Holes.
1 Hammer
1 Set of screw drivers
1 Extension cord
1 Electric screwdriver
1 Electric drill
1 A set of metal drill bits ¼” TO 5/8”
1 Hammer drill
1 A set of concrete drill bits
¼” TO 5/8”
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 9
1-800-558-7068
Installation
515 Roll-Up
Face Frame Installation
N O T E
Only ASI DOORS Qualified personnel are authorized to carry out this work
1. The ends of the Steel Channels with the black plastic Reintroduction Blocks go to the insides of the Header Brackets.
2. Position ends of Side Track of each side door post flush to wall side, and bottom edge of the Header Brackets.
3. Attach both side door posts to the Roll/
Header brackets using Splice Bracket and fasteners on 2 studs shown. Hardware is provided in Loose Parts box.
Note: Reintroduction Blocks flex towards center of opening during door opening and closing.
DO NOT Restrict movement of Reintroduction Blocks.
1
3
2
Optional
Side Cover
1
1
Figure 4: Assembly on the Ground.
Page 10 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Header Installation
C A U T I O N
Protect the Drum and Door Panel during installation of the door.
Installation
515 Roll-Up
Lift the door using the fork lift, and move it to the construction opening.
Figure 5: Lifting of the Door.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 11
1-800-558-7068
Installation
515 Roll-Up
Header Installation
Continued...
C A U T I O N
The attachment of the roll assembly and the door posts to the wall must be carried out with appropriate methods. The installer must ensure that the fasteners are suitable for the size of the door and the type of walls; if necessary, increase the number of fasteners used.
C
HECKS BEFORE THE
I
NSTALLATION OF THE
D
OOR
:
1. Measure the floor level left to right and shim under side door posts if necessary.
2. Place the entire structure around the construction opening.
3. The inner dimension B, between the black plastic door guides, must be equal to the width of the door opening stated on the production data sheet and customer order form that has been supplied with the door.
4. Please ensure that the parts are level/plumb (roll assembly and door posts)
Figure 6: Attachment to the Wall.
N O T E
For an optimum seal, the gaps between the door structure and the walls of the building must be filled. Please consult the customer with regard to the choice of materials to be used (caulk, silicone, etc.).
Page 12 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Curtain Alignment
Installation
515 Roll-Up
I
MPORTANT TIPS TO INSTALL THE DOOR PROPERLY
:
- Insure the bottom of the door curtain is taught but not too tight when closed. A curtain that is too tight will prevent the door from closing properly.
- Locate and attach the posts to the wall with the mounting screws in the center of slots for adjustment later if needed.
- Repeat this operation with the bottom of curtain at several different heights, to ensure a correct position of the side door posts for optimum operation and sealing.
Figure 7: Installing the Curtain properly.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 13
1-800-558-7068
Installation
515 Roll-Up
Curtain Alignment
Continued...
Remove the protective packaging of the Roll Assembly without damaging the Curtain. Lower the door manually by turning the motor with the extension piece supplied at the bottom of the Control Box, and insert the guiding cord into the Reintroduction Block.
When attaching Door Posts to wall, make sure that they are plumb & level, and hold 90° in upper 2 corners. This will allow Curtain to hang straight.
Figure 8: Curtain alignment.
Page 14 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Curtain Alignment
Continued...
I
NSERTING THE RETAINING
S
TRAPS INTO THE
S
IDE
G
UIDES
:
Remove the protective packaging of the
Roll Assembly without damaging the curtain.
Lower the door down manually by turning the motor with the extension piece supplied at the bottom of the
Control Box and insert the Guiding
Cord into the Reintroduction Block.
Installation
515 Roll-Up
Figure 9: Inserting the Retaining Edge.
Figure 10: Correct position of the Curtain with Door open.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 15
1-800-558-7068
Installation
515 Roll-Up
Curtain Alignment
Continued...
Lock the main power disconnect switch (with a padlock) before doing this.
M
ANUALLY CLOSING THE DOOR
:
Insert the supplied hex drive into the end of the Motor. Turn the ratchet to move the door open or closed.
6mm Hex Socket
Supplied with door
(Ratcheting wrench not supplied)
Figure 11: Manual opening or closing using ratchet.
C A U T I O N
Note: Use of a powered drill or impact driver is NOT recommended, and may damage the motor or hex drive.
Page 16 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Precautions with Frequency Inverter
Installation
515 Roll-Up
When a Frequency Inverter has power supplied to it, the electrical elements and a number of operating controls are also ‘live’. Never touch these elements. This is extremely dangerous. The cover of the Frequency Inverter must always be closed.
When the emergency stop is activated, the Frequency Inverter remains 'live'’. If this is a threat to the safety of the staff, the power circuit must be interrupted by locking the main switch on the Control Box.
After turning off and locking the Main Power Switch, it is always necessary to wait 5 minutes before starting work. This is the time required to discharge the capacitors of the
Frequency Inverter.
The Frequency Inverter has integrated safety systems for stopping the door. A mechanical block, fluctuations in voltage and interruptions of the power supply, can also bring a door to a stop. This is shown with a fault message on the Frequency Inverter Screen. After locking the Main Switch, and having removed the blockage, the Main Switch has to be unlocked and the door opened manually to re-charge the Frequency Controller.
In the event of work (on the electrical and/or mechanical part of the installation), the power supply to the Frequency Inverter must be switched off; to do this, the Main Switch on the
Control Box must be locked.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 17
1-800-558-7068
Installation
515 Roll-Up
Warranty and Liability
Check all warnings weekly. Door may unexpectedly close. Failure to mount and maintain
all Warning Labels and Instructional literature could result in death or serious injury.
Two Warning Labels are provided (Figure 12). Mount the Warning Labels approximately 60” from the floor. One Label should be on the Operator side on the mounting wall surface. The other Label should be located on the other side of the wall, opposite of the Operator.
Figure 12: Warning Label installation - Wall Mount.
Warranty claims will only be considered if the door was being operated and treated correctly. In the event of unauthorized repairs and modification to the construction and the operation of the door, the warranty will be invalidated. This rule also applies to damage resulting from defects that are the consequence of failure to follow the operating instructions or of inadequate maintenance of the door.
Page 18 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Electrical Controls
Installation
515 Roll-Up
Control Box contains HIGH VOLTAGE! The following procedures should be performed by qualified personnel only. Wiring must meet all local, state, federal and international, or other governing agency codes. Keep hands and body parts clear of High Voltage areas. Failure to do so could result in death or serious injury.
Disconnect power at the fused disconnect during all electrical or mechanical service. Disconnect must be properly locked out during maintenance or service or equipment. Failure to do so could result in death or serious injury.
N O T E
Wiring must be completed by a licensed electrician. All wiring connections must be in accordance with all local. state, federal, NEC or other governing agency codes. Reference electrical drawings shipped with door.
N O T E
Refer to electrical schematic for connections.
1.Make sure prewired cable supplied is of sufficient length to enable location of Control Box where desired. Mount Control Box to a convenient location, leaving sufficient room for Control Box door to be opened.
2.All wiring should be installed and connected by a qualified electrician who is knowledgeable with NEC
Article 430 and with local regulations. Electrician should make sure that the voltage and frequency of the electrical supply corresponds with the motor data listed on the Control Box cover.
C A U T I O N
Protect and cover all electrical components inside the Control Box prior to drilling enclosure.
Failure to do so may result in component malfunctions.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 19
1-800-558-7068
Installation
515 Roll-Up
Electrical Controls
Continued...
N O T E
Fused disconnect complying with applicable electrical codes must be supplied by others.
3.Prewired cable from motor Must Not be Spliced. Run this cable to Control Box (Figure 13).
4.From a fused disconnect, route power supply wires to the Control Panel and connect to terminal blocks
“L1”, “L2”, “L3”. Also attach a ground to Control Panel terminal.
5.All connections for Motor, Encoder, Photoeyes, Anti-Roll Switch, and any Activation Devices should be made per the schematic. All wiring connections from harness MUST be terminated in the Control Box
(see Figures 13 & 14).
N O T E
Any wiring by others MUST come into control box from bottom as shown, or Warranty is
Void.
Prewired Motor Cable
Supplied by ASI - Installed by others.
DO NOT SPLICE
Control Box
Incoming Power and
Activators by others.
Encoder, Photoeye Cables, and Anti-Roll Switch wires by ASI. Connections by others. (See figure 14)
Figure 13: Wiring Installation.
Page 20 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Electrical Controls
Continued...
Installation
515 Roll-Up
Install the control box at a location agreed with the user. Check that the power supply agrees with the control panel rating. If necessary, modify.
Connect the following in accordance with the electrical diagram and the specific notes supplied with the door:
- The motor- DO NOT SPLICE THE SUPPLIED HIGH VOLTAGE MOTOR CORD – IT HAS SHIELDING
THAT IS REQUIRED FOR PROPER DRIVE OPERATION.
- The wires for the absolute encoder that controls the OPEN/CLOSED positions of the door.
- The photoelectric cell wires from each side frame (see illustration below for routing non-drive side
cable).
- Opening and Interlocking control devices.
Activate the emergency stop button and check whether the magneto-thermal main switch is off. Check that the power cable is not 'live' and connect the switch to the power supply.
An opening has been provided in the side plate to pull the photoelectric cell cables through the header tube.
Mark/Tape for Upper and Lower Photoeye
Cables before pulling through.
Option:
Second set of Photoeyes
Gray
Black
Black
Gray
Connect the two wires for the
Anti-Roll Switch to terminals 1 and 4 of the Control Box.
Anti-Roll Switch
(mounted on drive side).
Figure 14: Electrical Connections.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 21
1-800-558-7068
Installation
515 Roll-Up
Electrical Controls
Continued...
The ASI Doors Door Controller monitors all operations of the door.
You use this device to:
- Define the automatic close timers,
- Monitor and troubleshoot the input connections,
- Interpret and correct any malfunctions or alarms.
Note: The door will not run until the Controller display reads ‘Ready’.
A
Connections to Variable
Frequency Drive
B
C
D
E
GND
0-10V
UP
+V
DOWN
V
F
D
MESSAGE DISPLAY COUNTER
Inputs
Outputs
5
6
7
8
9
10
2
3
4
PULL CORD/PB
MOTION/LOOP
REV EDGE
PHOTO
DRIVE ERROR
OPEN PB
CLOSE PB
E-STOP/RESET
IN 1
I
N
P
U
T
S
11
12
13
14
15
OUT 1
COM 1
OUT 2
OUT 3
COM 2/3
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU
ENTER
PROGRAM
MC/PB
DYNALOGIXII
T
S
T
P
O
U
U
ALWAYS INSPECT DOORS FOR PROPER OPERATION
AFTER RESETTING ANY ALARM CONDITION
REFER TO OWNERS MANUAL FOR FURTHER DETAILS. 1-800-459-1930
TYPE
INPUT
TYPE
INPUT
OUTPUT
COLOR
GREEN
RED
FLASH
RED
LED STATUS
CONDITION
NORMALLY OPEN INPUT TRIGGERED
CONDITION
ALARM CONDITION – CHECK INPUT
POWER
24VAC
1 X2 GND
S
H
L
D
ENCODER
+
12
G
N
D AA+
S
H
L
D
W
H
T
B
L
K
R
E
D
G
R
N
Figure 15: Controller.
Encoder Wire
Connections
Message
Display and
Cycle
Counter
Jog Buttons,
Run Timers,
Close Timers,
Program
Buttons, and
Limit Settings
Page 22 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
General Information
Electrical Installation
515 Roll-Up
C A U T I O N
Ensure that the incoming supply for the door is compatible with the transformer, motor, and inverter.
Frequency Inverter Voltage Range:
120 V = Single Phase
480 V = 3 Phase
230 V = Single Phase or 3 Phase
208 V = Single Phase or 3 Phase
Failure to ensure compatible power supply may result in fire and will damage the door.
C A U T I O N
Refer to the electrical schematic shipped with the door for appropriate circuit protection.
C A U T I O N
Ensure that the electrical installation for this door complies with the National Electrical
Code (NEC) and/or your local electrical code.
Primary Connections
1. Connect the incoming power. CAUTION: Run
the wires (conduit) through the BOTTOM of the
Control Box, up the left side, and connect them into the terminal strip or optional disconnect. (See
Figure 16). Bringing in power from the top of the
Control Box will void the Warranty.
- For a 3-phase unit, use terminals L1, L2, and L3.
- For a Single Phase unit use terminals L1 and L2.
L1 L2 L3
Power
Connections
Figure 16: Power Connections in the Control Box.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 23
1-800-558-7068
Electrical Start-Up
515 Roll-Up
Electrical Installation
C A U T I O N
M
AKE THE
P
RIMARY
C
ONNECTIONS
:
2. Connect the grounding wire (ground w ires and shield wire) to the ground terminals. (See Figure 17)
3.Connect the motor wires (black) to t erminals T1, T2, and T3. (See Figure 17)
4.
Make the Anti-Roll Switch connection to the Terminal Strip. (See Figure 17)
Ground
Motor Leads
T
1
T
2
T
3
X2
X2
2
3
1
1
1
1A
1B
4
8
GND
L1
L2
L3
T1
T2
T3
WDD
ANTI-ROLL M.S.
Anti-Roll Switch
(In Door Header,
PE1
Figure 17: Ground Connections on Terminal Block.
Page 24 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Electrical Start-Up
Photoeye Connections
1. Connect the photo-eye wiring to the Photoeye Base. See Figure 20.
- Connect the white wire in the grey transmitter cable to screw 5 on
Photo-Eye Amplifier base.
- Connect the shielded wire in the grey transmitter cable to screw 7 on Photo-Eye Amplifier base.
- Connect the white wire in the black receiver cable to screw 6 on
Photo-Eye Amplifier base.
Terminal
Strip
- Connect the shielded wire in the black receiver cable to screw 8 on
Photo-Eye Amplifier base.
Figure : Photo Eye Connections - CONFIRM WITH ELECTRICAL
DRAWINGS SUPPLIED WITH DOOR
2. Plug the photo eye amplifier into the 11-pin socket. See Figure 18.
3. Confirm set up of the amplifier.
See Figure 40 on Page 37 and Figure 41 on Page 38.
Wireless Detector
Base
515 Roll-Up
Photo-Eye
Amplifier
Figure 18: 11 Pin Socket for
Photoeye Amplifier.
Figure 19: Terminal Strip, Wireless
Detector, and Photo-Eye Amplifier.
White
Shield
Black
Grey
Receiver Transmitter
Upper Photoeyes (Optional)
White
Shield
4
5
6
7
8
Photo-Eye Amplifier Base
9
3
2
1
White
Shield
Grey Black
Transmitter Receiver
Lower Photoeyes (Standard)
White
Shield
Figure 20: Photoeye Base, Transmitter and Receiver Wiring.
4
5
6
7
8
Photo-Eye Amplifier Base
9
3
2
1
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 25
1-800-558-7068
Electrical Start-Up
515 Roll-Up
Photoeye Connections
Continued...
N O T E
1 Photoeye set is standard, 2nd Photoeye set is optional.
Reverse the Grey and Black locations on the Side Frames for upper Photoeye installation.
Black Receiver
Grey Transmitter
2nd Optional
Photoeye Set
Standard Photoeye Set
Figure 21: Photoeye arrangement with two
sets of Transmitters and Receivers installed.
Grey Transmitter
Black Receiver
Page 26 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Encoder Connections
Insert the wires into the green connector as listed below.
(Terminals are ordered left to right.) See Figure 22.
Shield = terminal 1
White = terminal 2
Black = terminal 3
Red = terminal 4
Green = terminal 5
Shield
White
Electrical Start-Up
515 Roll-Up
Figure 22: Wiring the Green Connector.
Green
Red
Black
2. Insert the green connector into the Controller. See Figure
23.
Figure 23: Insertion point for
the Green Connector.
Insertion point for
Green Connector
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 27
1-800-558-7068
Electrical Start-Up
515 Roll-Up
R
UN
W
IRE FOR
A
CCESSORIES
:
Wiring Accessories
Run the wiring for the activation accessories but do not connect them. See the appropriate appendices in this manual for wiring. Connect the activation accessories after the installer has finalized the door.
Turn on the Main Power.
Read and understand the Start-Up procedure in this manual before attempting to power-up the door.
Failure to do so could result in damage to the door and/or death or serious injury to the installer and will void the warranty.
Main Disconnect
(Optional)
Figure 24: Main Disconnect.
The Controller display should read SET LIMITS on initial power up. See the Section titled “Set Door Limits” for more information on setting the door's limits.
Final Checks and Verification
Finalizing the door includes setting the door's open and close limits, ensuring that the door works properly, and connecting the activation accessories.
Note: An electrician should connect the accessories to the terminal block if possible.
Before you begin:
Verify that the wiring is properly connected and the Control Box has power.
Confirm that the connections are properly grounded.
Confirm that the cable connections are positioned in their terminal slots correctly.
Page 28 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Set the Door Limits
Controller Set-Up
515 Roll-Up
C A U T I O N
Automatic activations should be disconnected prior to setting limits. If connected, the door may activate and injury or damage may occur.
The Controller controls and monitors the curtain's open and closed position. Once you set the all the limits, test the door to ensure that it is working properly.
1. Enter the programming mode.
2. Press and hold both PROGRAM buttons until display changes to Password.
After display changes, release buttons.
See Figure 38.
Press and release one of the PRO-
GRAM buttons to scroll up or down until the password, 777, displays in the LCD.
Press and release the ENTER button. LimitSet displays in the LCD.
See Figure 26.
MESSAGE DISPLAY COUNTER
Password
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 25: Controller Program Mode.
PRO-
GRAM
MESSAGE DISPLAY COUNTER
LimitSet
N O T E
On initial start up the Password screen will be bypassed, and the Controller will directly enter the LimitSet screen. See Figure 26.
If this is the initial startup, skip Step #1 & #2, and go to Step #3 (Page 30). If not, start at Step #1.
JOG
UP/RESET
JOG
DOW N
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PRO GRAM
Figure 26: ENTER Button.
N O T E
The door is out of phase if it moves up instead of down. Turn power off and switch T2 & T3 on the terminal block. Turn power on and return to Step One.
ENTER
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 29
1-800-558-7068
Controller Set-Up
515 Roll-Up
3. Set the close limit position.
Press and release the Enter button. ClsLimit displays in the LCD.
Press and release the Enter button. JogToCls displays in the
LCD.
Press the JOG DOWN button to bring the door down to desired close position. See Figure 27.
Press and release the ENTER button to save limit setting.
ClsLimit_Set—OK displays in the
LCD.
4. Set the photoeye shut-off position.
Press and release one of the
PROGRAM buttons to scroll up or down until the PhtLimit message displays in the LCD (photo eye shut off position). See Figure 28.
Press and release ENTER button.
JogToPht_Enter displays in the
LCD.
Press the JOG UP/RESET button to bring door up one inch above the photo eyes.
Press and release the ENTER button to save limit setting.
PhtLimit_Set—OK displays in the
LCD.
JOG
DOWN
Button
JOG UP
Button
Set the Door Limits
Continued...
MESSAGE DISPLAY COUNTER
JogToCls
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 27: JOG DOWN Button.
MESSAGE DISPLAY COUNTER
PhtLimit
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 28: JOG DOWN Button.
Page 30 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Set the Door Limits
Continued...
5. Set the open limit position.
Press and release one of the
PROGRAM buttons until the Opn-
Limit message displays in the
LCD.
Press and release the ENTER button. JogToOpn_Enter displays in the LCD.
Press and release the JOG UP/
RESET button until the door is in the desired open position (roughly an inch and a half above the reintroduction point). See Figure 29.
Press and release the ENTER button to save limit setting. Opn-
Limit_Set—OK displays in the
LCD.
6. Press and release the MENU button twice. Ready displays in the LCD.
See Figure 30.
7. Press the JOG buttons to test the open and close limits. Install and Test
Activation Accessories.
JOG UP
Button
Controller Set-Up
515 Roll-Up
MESSAGE DISPLAY COUNTER
JogToOpn
Enter
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 29: JOG DOWN Button.
MESSAGE DISPLAY COUNTER
Ready
####
MENU
Button
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU
ENTER
PROGRAM
Figure 30: MENU Button.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 31
1-800-558-7068
Controller Set-Up
515 Roll-Up
Install Activation Devices
I
NSTALL AND
T
EST
A
CTIVATION
A
CCESSORIES
:
The Controller has nine inputs. Inputs are signals coming to the Controller that get interpreted to create a certain response. For example, if a pull cord is wired to terminal 2, pulling the cord sends a signal to the
Controller. The Controller knows what the signal is based on the assigned input (terminal 2), thus moving the door up or down. All the inputs have indicator lights and identification. See Figure 31.
Figure 31: Accessory Inputs.
C A U T I O N
Install, connect, and then test each of the activation accessories individually before proceeding to the next accessory. This allows troubleshooting of each component individually.
Page 32 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Set Timers
Controller Set-Up
515 Roll-Up
S
ET
A
UTOMATIC
T
IMERS
:
The Open Run Timer and Close Run Timer act as a failsafe to prevent the door from running continuously when the open or close limit switch fails to stop the door. These timers should be set for a period that exceeds the duration of a full open or close cycle.
Press and release the OPEN run timer button. Opening_Time=## displays in the
LCD. See Figure 32.
Open/Close
Run Timers
Press and release the PROGRAM buttons to change the countdown time to the desired duration. See Figure 33.
The Controller automatically saves the changes.
Press and release the CLOSE run timer button. Closing_Time=## displays in the
LCD.
Press and release the PROGRAM buttons to change the countdown time to the desired duration. The Controller automatically saves the changes.
MESSAGE DISPLAY COUNTER
Opening
Time = ##
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 32: RUN TIMERS Buttons.
Increase
Setting
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 33: Adjust Countdown Time.
Decrease
Setting
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 33
1-800-558-7068
Controller Set-Up
515 Roll-Up
S
ET
T
HE
MC/PB T
IMER
:
The MC/PB timer activates a countdown timer for use with an activation installed on terminal number 2 (most commonly used for pull cords or push buttons). The MC/PB timer may be turned on or off, enabling manual operation or automatic operation by assigning a countdown value to the timer.
Press and release MC/PB close timer button. MC Delay_Time=## displays on the
LCD. See Figure 34.
Press and release the PROGRAM buttons to change the countdown time to the desired duration (Maximum time 99 seconds). See Figure 35.
The Controller automatically saves the changes.
MC/PB
Timer
Set Timers
Continued...
MESSAGE DISPLAY COUNTER
MC Delay
Time = ##
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 34: MC/PB Timer Button.
Increase
Setting
N O T E
If the value is set to zero, the timer is deactivated and the activations put on terminal number 2 are now in manual operation. Press and release the PROGRAM buttons to change the countdown time to the desired duration.
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 35: Adjust Countdown Time.
Decrease
Setting
Page 34 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Set Timers
Continued...
S
ET
T
HE
AC/LOOP T
IMER
:
The AC/LOOP timer activates a countdown timer for use with a motion detector or floor loop. The AC/LOOP timer is also used when the reversing edge is triggered
Press and release AC/LOOP close timer button. AC Delay_Timer=## displays on the LCD.
Press and release MC/PB close timer button. MC Delay_Time=## displays on the
LCD. See Figure 36.
Press and release the PROGRAM buttons to change the countdown time to the desired duration (Maximum time 99 seconds). See Figure 37.
The Controller automatically saves the changes.
Controller Set-Up
AC Delay
Time = ##
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
515 Roll-Up
MESSAGE DISPLAY COUNTER
Figure 36: AC/LOOP Close Timer.
AC/LOOP
Timer
Increase
Setting
N O T E
If the value is set to zero, the Door will come down when it reaches the open limit, after receiving an AC/Loop input, a reversing edge input, or a Photo-eye input.
JOG
UP/RESET
JOG
DOWN
OPEN
RUN
TIMERS
CLOSE
MC/PB AC/LOOP
CLOSE
TIMERS
MENU ENTER
PROGRAM
Figure 37: Adjust Settings.
Decrease
Setting
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 35
1-800-558-7068
Controller Set-Up
515 Roll-Up
A
NTI
-R
OLL
S
WITCH
:
Calibrate WDD Reversing Edge
The anti-roll switch is field wired after the door is installed into the #1
& #4 terminals (Figure 38). The purpose of the anti-roll switch is to quickly reverse the door if the curtain un-ravels off the barrel quicker than it can come down the guides. This is to prevent damage to the curtain, and to avoid the entire curtain unraveling inside the shroud.
This is a safety device and should not be disconnected unless trouble shooting.
WDD
REV EDGE
1
ANTI-ROLL M.S.
4
Figure 38: Anti-Roll Switch wiring.
W
IRELESS
D
ETECTION
D
EVICE
:
The WDD receiver provides a wireless connection to the bottom edge of the curtain. The WDD receiver programming persists even if the control box power is disconnected.
1. Turn on the main disconnect.
A red LED illuminates across from connector 9 indicating that the WDD is operational and ready for programming.
2. Lower the door to working level and press the e- stop button.
3. Push and hold the micro switch next to the LED using a small screw driver (see figure 39).
4. A green LED illuminates. Activate the edge on the curtain. The LED will go out. Release all buttons.
5. Test the setting by activating the bottom edge. An audible click should be heard and the Controller
LED should illuminate.
Figure 39: WDD Receiver.
Page 36 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Photocell Installation and Set-Up
Confirm Photocell Amplifier is seated properly in gray eleven-pin socket.
Confirm adjustment knob is in the auto position.
Confirm power on.
Lights 1 & 2 will illuminate green. Lights 3 & 4 will illuminate amber. Refer to Figure 40
After door limits are set, verify operation of photocells by blocking beam and assuring the door reverses.
Under normal operations lights 3 & 4 will go out when beam is blocked.
L1 - Illuminated if in Auto Mode
L2 - Illuminated to DIP Switch one's setting:
A = Green
B = Amber
L3 - Indication of operation:
Red = Alarm Condition
Amber = Good Signal
Non = Beam broken or alignment switch turned on.
L4 - Illuminated when beam not blocked.
L1
L2
L3
Auto
Controller Set-Up
S142ARNT924
515 Roll-Up
Dist.
ON
1
2
3
4
5
6
Code A
Code B
Alarm
Signal
Output
Code A/B
Alignment
Level Low/High
Power 50/100
NC/NO
Out/Alarm
L4
Figure 40: Photoeye Amplifier Controls.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 37
1-800-558-7068
Controller Set-Up
515 Roll-Up
Photocell Installation and Set-Up
Continued...
DIP S
WITCH
D
ESCRIPTION
:
DIP Switches come preset and need not be adjusted unless otherwise advised. Refer to Figure 38.
DIP Switch 1 - Controls the switch code A or B.
Code A - Single photocell
Code B - Two sets of photocell, avoids crosstalk between them
DIP Switch 2 - Alignment of photocell.
ON - Able to tune photocell via manual adjust dial/ physical alignment of photocell. L3 will illuminate steady for a strong signal or blink slowly for a weak signal.
OFF - Normal operation/L3 illuminated.
DIP Switch 3 - This switch selects the power gain. Low or
High.
DIP Switch 4 - Power level 50% or 100%.
DIP Switch 5 - Selection on output contact N/O or N/C.
DIP Switch 6 - DIP Switch needs to be left in Alarm position, used to alarm when photo eyes shorted or malfunctioning.
Figure 41: Photoeye DIP Switch Presets.
I
NSTALL
C
OVERS
:
As a final step, ensure that all Covers are installed on the
Door.
Motor / Fabric Roll
Side
Page 38 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Error Messages
Table 1-1 describes the messages that the Controller displays.
Message Display
Ready ####
Pull Cord
Motion/Loop
E-stop/Reset
Drive Error
Photo Eye
Rev - Edge Tripped
Opening Expired
Closed Expired
SET LIMITS
ENCODERCOM_LOSS
The display screen is blank.
The door reverses before reaching the closed limit.
Maintenance
515 Roll-Up
Trouble Shooting
All required connections are correct and the door is ready for operation. The number indicates the cycle counter. The Controller will not allow the door to operate unless this message displays.
The pull cord activation input terminal # 2 has a closed connection. Check all activation devices and make sure they are wired on the normally open input.
Get for stuck pull cords or push buttons.
The motion detectors activation input terminal # 3 has a closed connection.
Check all activation devices and make sure they are wired on the normally open input. Check sensitivity on activation device wired into terminal #3.
The E-stop button is not releases so the door can operate. Check E-stop button, make sure jumper wire is installed into terminal #1 &1A if a remote E-stop button is not used.
A drive error occurred. Check VFD display for error code if "dcb" is displayed check the wiring to the VFD. If any other message is displayed on the VFD, check all wiring connections to the "T" and "L" leads. Verify the proper voltage is being supplied to the control panel. Verify that there are no motor disconnect switches turned off.
The photo eye is not wired properly. Check wiring, make sure the eyes are aligned.
Check for damaged eye. Check gain levels. Replacement of eyes may be necessary.
The reversing edge or anti-roll switch is tripped. The reversing edge is a normally open circuit and will not fail open, the door will continue to operate with out the edge. Also check any other reversing device that may be wired into terminal and input # 4.
The open run time timer expired. Press and release the E-stop button to clear the fault.
Jog the door open and closed and verify there are no mechanical problems. The open run timer may be set too low. Press the "open run timer" and increase the second with the "program up arrow" (usually 10 seconds is sufficient).
The close run time timer expired. Press and release the E-stop button to clear the fault. Jog the door open and closed and verify there are no mechanical problems. The close run timer may be set too low. Press the "close run timer" and increase the second with the "program down arrow" (usually 10 seconds is sufficient unless the closing speed has been slowed down).
The limits have not been set. Set limits (see Section 1.3.1: Set the Door Limits for instructions.)
The encoder is not communicating with the controller. Check the wires connections on the harness that plugs into the controller for loose connections. The encoder may be damaged and may need to be replaced.
Check fuse # 6. Check incoming power, make sure the harness is plugged into the controller.
See "Anti-Roll Switch" trouble shooting section, page 42-43.
Table 1-1: Controller error messages.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 39
1-800-558-7068
Maintenance
515 Roll-Up
Preventative Maintenance
Remove power at the fused disconnect during ALL electrical or mechanical service. Disconnect MUST be properly locked out during maintenance or ser-
vice of equipment. Failure to do so may result in death or serious injury.
N O T E
For Monthly and Quarterly inspections, record the date of inspection and the cycle count. The cycle counter is located in the Control Box. Recording Daily inspections is usually not necessary.
Curtain Inspection
Test Door Operation
Inspect All Activation Devices
Test Reversing Edge and Photoeyes
Inspect Re-Introduction System
Inspect Side Guides
Inspect Cabling
Inspect all Mounting Hardware
Inspect Operator Assembly
Inspect Electrical Control Box
Inspect Bearings
Daily Monthly Quarterly
Page 40 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Preventative Maintenance
Continued...
Maintenance
515 Roll-Up
Daily
Monthly
1. CURTAIN INSPECTION: Visually inspect the door for any damage that may be present. Example: Condition of the welds, condition of the bead. Clean curtain with soft cloth soaked in water, if necessary mixed with a soft cleaning agent.
1. INSPECT REINTRODUCTION SYSTEM: Visually inspect reintroduction block for any physical damage. Bearing wheels should move freely.
2. TEST DOOR OPERATION: Run the door several cycles to see if the door is operating properly. Check to see that door is operating smoothly with no binding or unusual noises.
Make the necessary adjustments if the door is not operating correctly. Do not leave the door in operation if a problem exists. side guides for any physical damage. Make sure black side guide extrusion doesn’t move up or down more than 1/8” during door operation. bles and harness for any breaks or cracks. If damaged repair or replace immediately.
Check condition of the electrical connections.
3. INSPECT ALL ACTIVATION DEVICES: Inspect all activation devices to insure proper actuation of the door. Make the necessary adjustments if the door is not operating correctly.
If activation devices are not functioning, the door should be immediately taken out of service.
4. TEST REVERSING EDGE AND PHOTOEYE:
The reversing edge and photoeyes should be checked on a daily basis as outlined in the instruction manual. While the door is traveling to the closed position, test reversing edge for proper operation. Also, check reversing photoeye to ensure proper operation when the beam is interrupted. Make the necessary adjustments if the door is not operating correctly.
Do not leave the door in operation if a problem exists.
Quarterly
1. INSPECT ALL HARDWARE: Insure that all bolts, screws, anchors and welds are intact and securely fastened.
2. INSPECT OPERATOR ASSEMBLY: Over time due to heavy operating cycles, the bolts associated with the drive unit could become loose. Check to insure that all bolts are secure on the drive motor assembly. Examine the entire drive system for any sign of leaking or broken seals. Replace as necessary.
3. INSPECT ELECTRICAL CONTROL BOX:
Disconnect power before opening panel cover. Check electrical box for any loose parts or wires. Repair and replace as necessary.
Check all circuit relays and timers to ensure their proper operation. Replace if necessary.
Reminder: record the number of cycles at each monthly and quarterly inspection.
4. INSPECT BEARINGS: Check barrel bearings to ensure they are tight and holding the barrel without any rubbing. Adjust if necessary.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 41
1-800-558-7068
Maintenance
515 Roll-Up
A
NTI
-R
OLL
S
WITCH
E
RROR
:
Anti-Roll Switch
Anti-Roll Switch Error:
The door travels towards the close position and reverses open, when this happens the # 4 “reversing” input illuminates momentarily. The door usually continues to try to close and re-opens and continues this pattern until the E-stop button is pressed.
Difference between the “reversing” input and “anti-roll” switch:
The anti-roll switch is located on the operator side of the door in-between the curtain and the wall.
Both the reversing edge and anti-roll switch are normally open inputs and share the same #4 “reversing input”. The reversing edge is hard wired into the wireless reversing device (WDD) and receives its signal only when the bottom edge makes contact with and object before reaching the close limit.
The anti-roll switch is field wired after the door is installed into the #1 & #4 terminals. The purpose of the anti-roll switch is to quickly reverse the door if the curtain un-ravels off the barrel quicker than it can come down the guides. This is to prevent damage to the curtain, and to avoid the entire curtain unraveling inside the shroud. This is a safety device and should not be disconnected unless trouble shooting.
Figure 42: Anti-Roll Switch location.
WDD
1
ANTI-ROLL M.S.
4
REV EDGE
Page 42 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Anti-Roll Switch
Continued...
Maintenance
515 Roll-Up
T
ROUBLE SHOOTING
&
CORRECTIVE ACTION STEPS
:
1. Insure that the guides have not been impacted and/or pinched. This will cause the door to travel to the area of damage and reverse during full speed operation. The guide will need to be replaced if the damaged area can not be pried open. Usually the door will not jog below damage in the guide.
2. Insure that the UHMW guide is not twisted in the reintroduction block. This will cause the curtain to bind in the first few inches of travel and will cause the anti-roll switch to reverse the door. The outer bearing will have to be removed as well as the 10mm bolt. The reintroduction block will have to be removed and re-.installed in alignment.
3. Insure that the guides are installed plumb & square and the barrel is level (review installation instructions in the owner’s manual). It may also be necessary to move one or both of the guides “in”. This is usually the case in extreme air pressure applications. This will require removing the guide cover(s), loosening the mounting bolts, and moving the guide(s) in slightly.
4. If the application temperature, on either side of the open, is subject to falling below 35 degrees, the door may experience difficulty closing. Consult with the factory for possible option if this occurs.
5. Insure that the anti-roll switch is not pried away from the wall. This may require the switch to be adjusted closer to the wall.
Figure 43: Curtain entering Re-
introduction Block.
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 43
1-800-558-7068
Replacement Parts
515 Roll-Up
Mechanical Service Parts List
Item # Part # DESCRIPTION
1 24A0105NV10 Drive Drum Assembly, with shafts, Steel
1 24A0105NV20 Drive Drum Assembly, with shafts, Stainless
2 24A0107NN10 Bearing, Drum, Steel
2 24A0107NN20 Bearing, Drum, Stainless
3 23A0404NN Motor,Gear reducer, Encoder 1 HP
3 23A0405NN Motor,Gear reducer, Encoder 2 HP
4 23A0406NV Cable, motor (per FT) ( Not Shown)
5 23A0400NN Encoder
6 23A0401NV Cable, Encoder (per FT) ( Not Shown)
7 23A0402NN Anti-roll switch with bracket - stainless
8 23A0403NV Cable, Anti-roll switch (per FT) ( Not Shown)
9 24A0122LV Inner Guide Assembly, LH
10 24A0122RV Inner Guide Assembly, RH
11 24A0104NN Re-introduction Assembly, Model 515
12 13B1735LV10 Cover, Face Frame, LH, 515 Roll-Up, HIC <= 120", Galvanized
12 13B1735LV20 Cover, Face Frame, LH, 515 Roll-Up, HIC <= 120", Stainless
12 13B1735LV31 Cover, Face Frame, LH, 515 Roll-Up, HIC <= 120", Smooth White
13 13B1737LV10 Cover, Face Frame, Upper LH, 515 Roll-Up, HIC > 120", Galvanized
1
1
13 13B1737LV20 Cover, Face Frame, Upper LH, 515 Roll-Up, HIC > 120", Stainless 1
13 13B1737LV31 Cover, Face Frame, Upper LH, 515 Roll-Up, HIC > 120", Smooth White 1
14 13B1736LN10 Cover, Face Frame, Lower LH, 515 Roll-Up, HIC > 120", Galvanized
14 13B1736LN20 Cover, Face Frame, Lower LH, 515 Roll-Up, HIC > 120", Stainless
1
1
14 13B1736LN31 Cover, Face Frame, Lower LH, 515 Roll-Up, HIC > 120", Smooth White 1
15 13B1735RV10 Cover, Face Frame, RH, 515 Roll-Up, HIC <= 120", Galvanized 1
15 13B1735RV20 Cover, Face Frame, RH, 515 Roll-Up, HIC <= 120", Stainless
15 13B1735RV31 Cover, Face Frame, RH, 515 Roll-Up, HIC <= 120", Smooth White
16 13B1737RV10 Cover, Face Frame, Upper RH, 515 Roll-Up, HIC > 120", Galvanized
16 13B1737RV20 Cover, Face Frame, Upper RH, 515 Roll-Up, HIC > 120", Stainless
16 13B1737RV31 Cover, Face Frame, Upper RH, 515 Roll-Up, HIC > 120", Smooth White 1
17 13B1736RN10 Cover, Face Frame, Lower RH, 515 Roll-Up, HIC > 120", Galvanized 1
17 13B1736RN20 Cover, Face Frame, Lower RH, 515 Roll-Up, HIC > 120", Stainless 1
17 13B1736RN31 Cover, Face Frame, Lower RH, 515 Roll-Up, HIC > 120", Smooth White 1
1
1
1
1
1
2
1
1
1
1
1
1
Qty
1
1
2
2
1
1
1
1
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Page 44 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Replacement Parts
Mechanical Service Parts List
Continued...
515 Roll-Up
Item # Part #
20
21
21
21
22
22
23
DESCRIPTION
18 24B0383NV10 Spreader Assembly, 515, WIC <= 120", Galvanized
18 24B0383NV20 Spreader Assembly, 515, WIC <= 120", Stainless
18 24B0383NV31 Spreader Assembly, 515, WIC <= 106", Smooth White
19 13B1711NV10 Spreader, Lower, 515, WIC <= 120", Galvanized
19 13B1711NV20 Spreader, Lower, 515, WIC <= 120", Stainless
20 13B1723NV10 Spreader Cover, 515, WIC <= 120", Galvanized
20 13B1723NV20 Spreader Cover, 515, WIC <= 120", Stainless
13B1723NV31 Spreader Cover, 515, WIC <= 106", Smooth White
24B0394NV10 Spreader Assembly, 515, WIC > 120", Galvanized
24B0394NV20 Spreader Assembly, 515, WIC > 120", Stainless
24B0394NV31 Spreader Assembly, 515, WIC > 106", Smooth White
13B1545NV10 Spreader, Lower, 515, WIC > 120", Galvanized
13B1545NV20 Spreader, Lower, 515, WIC > 120", Stainless
13B1543NV20 Spreader Cover, Center, 515, WIC > 120", Stainless
24 13B1544NV10 Spreader Cover, Outer, 515, WIC > 120", Galvanized
24 13B1544NV20 Spreader Cover, Outer, 515, WIC > 120", Stainless
24 13B1544NV31 Spreader Cover, Outer, 515, WIC > 106", Smooth White
25 24B0379LV10 Shroud Assembly, 1 Pc., 515, LH Drive, WIC <= 120", Galvanized
25 24B0379LV20 Shroud Assembly, 1 Pc., 515, LH Drive, WIC <= 120", Stainless
25 24B0379LV31 Shroud Assembly, 1 Pc., 515, LH Drive, WIC <= 106", Stainless
25 24B0379RV10 Shroud Assembly, 1 Pc., 515, RH Drive, WIC <= 120", Galvanized
25 24B0379RV20 Shroud Assembly, 1 Pc., 515, RH Drive, WIC <= 120", Stainless
25 24B0379RV31 Shroud Assembly, 1 Pc., 515, RH Drive, WIC <= 106", Stainless
26 24B0384LV10 Shroud Assembly, 2 Pc., 515, LH Drive, WIC > 120", Galvanized
26 24B0384LV20 Shroud Assembly, 2 Pc., 515, LH Drive, WIC > 120", Stainless
26 24B0384LV31 Shroud Assembly, 2 Pc., 515, LH Drive, WIC > 106", Smooth White
26 24B0384RV10 Shroud Assembly, 2 Pc., 515, RH Drive, WIC > 120", Galvanized
26 24B0384RV20 Shroud Assembly, 2 Pc., 515, RH Drive, WIC > 120", Stainless
26 24B0384RV31 Shroud Assembly, 2 Pc., 515, RH Drive, WIC > 106", Smooth White
27 13B1720NN10 Side Cover, Shroud, 515, Galvanized
27 13B1720NN20 Side Cover, Shroud, 515, Stainless
27 13B1720NN31 Side Cover, Shroud, 515, Smooth White
28 13B1788NN10 Shroud Retainer, Galvanized
29 24A0117NV Asm, Curtain, 515 Roll-Up Door
30 16B0052NV Window, Roll-Up Door, PVC, 28" H Per Sq Ft
30 16B0053NN Window, Roll-Up Door, PVC, 24" x 24"
1
1
31 24A0114LV Curtain edge repair, 515, LH (requires returning curtain to factory-shipping extra) -
32 24A0114RV Curtain edge repair, 515, RH (requires returning curtain to factory-shipping extra) -
1
1
A/R
1
33 05A0030NN Spare patch material - (Note color needed - White standard)
34 10A0041NN Loctite adhesive for spare patch material
35 50A0174NN 6MM_Allen Wrench - (For manual operation of door)
36 50A0175NN Teeth, Replacement, Panel Edge, 515
-
-
-
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
2
1
2
1
1
1
1
1
1
2
1
1
1
1
1
Qty
1
1
1
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 45
1-800-558-7068
Replacement Parts
515 Roll-Up
Service Parts - Door Curtain
See Page 44 & 45 for Part
Number Descriptions
30
29
29
29
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Page 46 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Service Parts - Motor Side
See Page 44 & 45 for Part
Number Descriptions
Replacement Parts
515 Roll-Up
3
11
1
5
Encoder (Inside
Motor Cover)
12
13
9
Side Frame
Channel
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 47
1-800-558-7068
Replacement Parts
515 Roll-Up
Service Parts - Idler Side
See Page 44 & 45 for Part
Number Descriptions
1
7
2
11
Side Frame
Channel
10
11
15 16
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Page 48 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Replacement Parts
Service Parts - Side Frames, and Drive Assembly
515 Roll-Up
See Page 44 & 45 for Part
Number Descriptions
27
1
18
11
3
11
19
22
20
22
Side Frame
Channel
9
24
23
24
21
10
15 16
17
Side Frame
Channel
12
13
14
N O T E
Item 27, Side Cover, is mounted behind item 19,
Lower Spreader Base.
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 49
1-800-558-7068
Replacement Parts
515 Roll-Up
Service Parts - Shrouds
See Page 44 & 45 for Part
Number Descriptions
Mounted to
Upper Spreader
Channel
28
28
27
25
28
27
27
Idler Side
26
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Page 50 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Electrical Service Parts list
Replacement Parts
515 Roll-Up
Item #
1
2
3
3
Part # DESCRIPTION
Consult Factory Enclosure, Control Box, composite
Consult Factory Sub Panel, Control Box, composite
Consult Factory Control Box Complete, 1 HP
Consult Factory Control Box Complete, 2 HP
4 23A0421NN ASILogix II Controller Board
5 23A0416NN VFD Drive ATV11 1hp Motor 110VAC
5 23A0417NN VFD Drive ATV31 1hp Motor 230VAC
5 23A0418NN VFD Drive ATV31 2hp Motor 230VAC
5 23A0419NN VFD Drive ATV31 1hp Motor 460VAC
5 23A0420NN VFD Drive ATV31 2hp Motor 460VAC
8 23A0431NN Emergency Stop Pushbutton
9 23A0432NN Nameplate, Emergency Stop, (one dozen nameplates)
10 23A0433NN Selector Switch, Airlock (Optional)
11 23A0434NN Nameplate, Airlock, ON/OFF (Optional)
12 23A0439NN Terminal block, 35A, Red (one dozen)
13 23A0438NN Terminal block, 35A, Black (one dozen)
14 23A0437NN Terminal block, Ground (one dozen)
15 23A0422NN Fuse 0.5 Amp 600V Class CC - (one dozen)
16 23A0423NN Fuse 2.0 Amp 250V Class M - (one dozen)
17 Consult Factory Transformer, Step-down, 208/230/460 50VA
1
1
Step-down, 1
17 Consult Factory Transformer, Step-down, 110V 100VA
18 23A0426NN Wireless Door Detector Receiver (DIN rail mount-no socket)
19 23A0427NN Relay 24VAC - DPDT (Optional, for special controls)
20 23A0428NN Socket, 24VAC- DPDT (Optional, for special controls)
21 23A0435NN Contactor, 2NO, 2NC (For Opt. Battery backup)
1
1
1
1
1
22 23A0409NN Photoeye Set (Includes transmitter, receiver, amplifier)
1
1
1
1
1
1
1
1
1
Qty
1
1
1
1
1
1
1
1
1
1
1
1
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 51
1-800-558-7068
Replacement Parts
515 Roll-Up
5
21
Service Parts - Electrical
See Page 51 for Part
Number Descriptions
19
17
15
16
20
14
18
5
12 13
15
4
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
2
Page 52 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
Service Parts - Electrical
Continued...
Replacement Parts
515 Roll-Up
See Page 51 for Part
Number Descriptions
1
6
11
7
9
8
10
When ordering parts, specify Job Number,
Door Number and
Manufacture Date
Manual Part Number: 17B066-062314 © 2014 ASI Doors, Inc. Page 53
1-800-558-7068
Replacement Parts
515 Roll-Up
Instructions for Ordering
This parts manual is intended to assist in the correct identification of the more commonly replaced parts; covering, the 515 Roll-Up model offered within the
Marathon Pharmaceutical. line. The manual will also help identify obsolete parts, part design changes and current production parts. For more specific parts information, please contact an authorized representative or consult the
Factory’s Customer Service or Engineering Departments. ASI Doors reserves the right to discontinue any part and make design changes without notice.
General Instructions for Ordering Door Parts
Accurate information is always necessary to serve you correctly and promptly. Several steps should be followed to determine exactly the parts that are needed.
Refer to the information tag on your door and record the:
1. Door model number
2. Job number
3. Door number
4. Manufacturing date.
Use part numbers listed, or item numbers referenced in this manual.
If the item is not found in the manual, the product code on the back of the item is helpful.
If your door has no information label, the approximate purchase date is helpful.
Once you have gathered the information above, call:
1-800-558-7068 or
Order Parts Online at: www.asidoors.com and follow the “Parts” link
Page 54 © 2014 ASI Doors, Inc. Manual Part Number: 17B066-062314
1-800-558-7068
® ® ®
, ,
ASI Doors, Inc. • 5848 N. 95th Ct. • Milwaukee, WI 53225