Operating and Maintenance Instructions Mira LED Exam Light Ceiling Mount w w w . a m i c o . c o m Contents Introduction3 Symbols Used in This Manual 4 Safety Instructions 5-7 Scope of Delivery 8 Installing Ceiling Mount 9-11 Installing Ceiling Arm 12 Installing The Lighthead 13 Operation14 Disinfecting, Cleaning and Sterilization 15 Maintenance16 Notes On The Arm Systems 17-18 Spare Parts 19 Disassembly20 Technical Data of the Lighthead 21 Technical Data of the Arm System 22 Warranty23 2 Amico Lights Corporation Introduction Thank you for your purchase of the Mira LED Minor Surgery Light. This installation manual gives you instructions on how to install the Mira LED Light for a Wall Mounted, Ceiling Mounted or Floorstand version of your purchase. For instructions on operation, maintenance and further description of the product please refer to the Operation and Maintenance Manual included. Please read the following instructions very carefully and follow the safety instructions and requirements. www.amico.com 3 Symbols Used in This Manual 1 SYMBOLS 1 SYMBOLS 1The SYMBOLS warning symbols indicate indicate all all instructions instructions that that are are important important for for safety. safety. Failure Failure to to comply comply with with them them can can lead lead to to injury, injury, symbols 1The warning SYMBOLS damagesymbols to the the luminaire luminaire or all theinstructions equipment. In Inthat combination with the thefor following signal words the warning warning symbols means: damage to or the equipment. combination with following words the symbols means: The warning indicate are important safety.signal Failure to comply with them can lead ENG SYMBOLS ENG SYMBOLS Thedamage warning to symbols indicate allorinstructions that are In important for safety. Failure to comply with them can lead towarning injury, to injury, the luminaire the equipment. combination with the following signal words the The warning symbols indicate all instructions that are important for safety. Failure to comply with them can lead to injury, DANGER DANGER damage to the luminaire or the equipment. In combination with the following signal words the warning symbols means: to the luminaire the or equipment. In combination with the following signal words the warning symbols means: symbols means: Can lead to to or death serious injury. injury. 1damage SYMBOLS Can lead death or serious 1 SYMBOLS DANGER DANGER Can lead to death or serious injury. Can lead to death or serious injury. WARNING WARNING ENG SYMBOLS ENG SYMBOLS The warningCan symbol or Can leadisto toused injuryfor all instructions that are important for safety. If warnings are ignored, users may be injured DANGER lead injury The warning symbol is used for all instructions that are important for safety. Ifthe warnings aresignal ignored, users may be injured or the light or surroundings may be damaged. The warning symbol is used with following words as follows: WARNING the light or surroundings may damaged. The warning symbol is used with the following signal words as follows: WARNING Can lead to be injury. 1 SYMBOLS Can leadwith to injury 1 WARNING SYMBOLS Comply operating instructions WARNING Can leadwith to injury Comply operating instructions WARNING Can lead to death or serious injury. May cause death or operating serious injury. Comply with instructions May cause death or serious injury. Comply with operating instructions Comply with operating instructions The warningCE symbol is used used for all all instructions instructions that that are are important conformity mark The warning symbol is for important for for safety. safety. If If warnings warnings are are ignored, ignored, users users may may be be injured injured or or CE conformity mark CAUTION the may the light light or or surroundings surroundings may be be damaged. damaged. The The warning warning symbol symbol is is used used with with the the following following signal signal words words as as follows: follows: CAUTION CE conformity mark May cause minor injury. CE conformity mark May cause minor injury. WARNING CE conformity mark WARNING May cause death or Protective conductor May cause death conductor or serious serious injury. injury. Protective conductor Protective earth Protective Protective earth Protective conductor Protective conductor CAUTION Neutral conductor/return conductor for the the electrical electrical current current CAUTION Neutral conductor/return conductor for the electrical Neutral conductor/return conductor for current Neutral conductor return line for current May minor Neutral conductor return line for current May cause cause minor injury. injury. Neutral conductor/return for the electrical current Live conductor conductor Liveconductor conductor Neutral conductor/return conductor for the electrical current Live conductor Live Protective earth Live conductor Protective earth Storage humidity Live conductor Live conductor Storage humidity humidity Storage Disposal Neutral Disposal Neutral conductor conductor return return line line for for current current Storage humidity Storage temperature Storage humidity Live conductor Storage temperature Live conductor Storage temperature Manufacturer Manufacturer Storage temperature Disposal Storage temperature Disposal Disposal Disposal Disposal Manufacturer Disposal Disposal Manufacturer Manufacturer Manufacturer Manufacturer Manufacturer Manufacturer Trademarks: All trade names mentioned in these instructions are the exclusive property of the relevant manufacturers. Publication Revision: 02/17/13 Trademarks: All All trade trade names names mentioned mentioned in in these these instructions instructions are are the the exclusive exclusive property property of of the the relevant relevant manufacturers. manufacturers. Trademarks: Publication Revision: Revision: 02/17/13 02/17/13 Publication Trademarks: All trade names mentioned in these instructions are the exclusive property of the relevant manufacturers. Trademarks: All trade names mentioned in these instructions are the exclusive property of the relevant manufacturers. Publication Revision: 02/17/13 Publication Revision: 02/17/13 4 Amico Lights Corporation Safety Instructions Intended use The Mira LED Minor Surgery Light is intended to provide illumination for minor surgery, diagnosis, or examination. It is to be used near the patient to support treatments, which pose no risk to the patient in the event of any interruption caused by light failure. It is meant for continuous operation. User profiles Medical staff All persons with medical training who work in the field for which they were trained. Cleaning staff All persons familiar with national and workplace hygiene requirements. Electricians All persons with training in electronics and electrical technology who are familiar with the relevant standards and regulations. Certified installers Persons qualified by training, experience and knowledge of the regulations to install and remove the equipment. Safety Instructions Please note that certain duties must be carried out by people with the appropriate corresponding qualifications. The instructions are part of the product and must be kept so they are accessible for all subsequent users: • These instructions are for the Amico Lights Mira Series LED lights. This includes ceiling, floorstand and wall mounted equipment. • Please carefully read these operating instructions before using the equipment. It will help protect you and others from potential injuries that may occur. • All work on the light (including repairs) must be done by qualified electricians only. The light must be installed by a certified installer. • The light must not be modified or manipulated. Use in any other manner than with the original parts may result in different specifications and life-threatening dangers. • Only persons with medical training are permitted to operate the equipment. • Only trained cleaning personnel are permitted to clean the equipment. • The light must not be used in an explosive environment. The power supply to the light is a potential ignition source. • The light must be used in dry rooms only. • The light must not be left on unattended. • Keep all flammable equipment and objects away from the Lighthead and cone during use. • Do not use a damaged light. Defective cables can also be a potential hazard. Do not position cables near heat sources or sharp edges. • Eye damage. Never look directly at the light cone. • Replace damaged lenses before using the light again. • The light must be connected to the mains with a protective earth to prevent electric shock. www.amico.com 5 Safety Instructions • Never apply additional loads to the Lighthead and spring arm. • Do not cover the light with a cloth or similar material while operating. • If problems are encountered that have not been addressed in these operating instructions, please contact your supplier in the interest of your own safety. Please keep these operating instructions in a secured place near the device. This ensures easy access to safety instructions and important information should the need arise. • The inspections and maintenance work, as described on page 30, should only be done by trained service technicians. Anyone else is not authorized to perform inspections and maintenance work. • The adjustment work should only be carried out by a hospital technician or someone with similar qualifications. Anyone else is not authorized to perform adjustment work. • This equipment has been built accordingly and is operationally safe. Nonetheless, it may still present some danger, especially if not used according to the operating instructions as specified in this manual. • Modifications are never to be made for any reason. This is to ensure safety for all persons involved. Any modifications made to the system void the warranty. • The contents of the operating instructions are subjected to change without notice. Specific fitting instructions Mira LED Ceiling Mount • Mounting material not included in delivery. • The ceiling mount may be fitted to ceiling only with a concrete strength of B25 (C20/25) or greater. • Contact with reinforcing elements of the solid slab ceiling must be avoided. In case of doubt, a structural engineer should control the mounting on the respective surface. • The drill holes should be made by a skilled person in accordance with the drill hole tolerances recommended by the manufacturer of the fastening anchors. • The screws must be carefully tightened using a torque wrench in accordance with the recommendations of the manufacturer of the fastening anchors. Mira LED Wall Mount • Mounting Material not included in delivery. The light may be mounted only on walls that guarantee sufficient hold. The necessary technical information can be found in the installation section of this manual. 6 Amico Lights Corporation operating instructions as to specified in this manual. Modifications are never be made for any reason. Modifications are safety never for to be made forinvolved. any reason. This is to ensure all persons Any This is to ensure safety forsystem all persons involved. Any modifications made to the void the warranty. modifications system void the warranty. The contentsmade of to thetheoperating instructions are The contents of the operating subjected to change without notice. instructions are subjected to change without notice. Safety Instructions 2.4 2.4 Warning levels Warning levels Warning levels DANGER DANGER Indication of hazards that can lead to death or serious injury if measures arethat disregarded. DANGER Indication of hazards can lead to death or serious injury if measures are disregarded. Indication of hazards that can lead to death or serious injury if measures are disregarded. WARNING WARNING Indication of hazards that can lead to injury if measures WARNING are disregarded. Indication of hazards that can lead to injury if measures Indication of hazards that can lead to injury if measures are disregarded. are disregarded. CAUTION CAUTION Indication of hazards that can lead to damage to CAUTION property if of measures disregarded. Indication hazardsare that can lead leadtotodamage damagetoto Indication of hazards that can property if measures are disregarded. property if measures are disregarded. EXPLOSION HAZARD EXPLOSION HAZARD EXPLOSION HAZARD The above is an explosion hazard warning symbol. NonThe above is an explosion hazard warning symbol. Non-compliance with this symbol may result in damages or injuries The above iswith an explosion hazard Noncompliance this symbol may warning result insymbol. damages or due to explosion. compliance with this symbol may result in damages or injuries due to explosion. injuries due to explosion. ELECTRIC SHOCK SHOCK ELECTRIC ELECTRIC SHOCK The above is an electric shock warning symbol. Non-compliance with this symbol may result in damages or injuries The above is an electric shock warning symbol. Nondue to electric shock. The above is an electric shock warning symbol. Noncompliance with this symbol may result in damages or compliance with this symbol injuries due to electric shock. may result in damages or injuries due to electric shock. 4 4 www.amico.com 7 Scope of Delivery Ceiling Mount Included: 8 1x Lighthead with sterilizable handle 1x ceiling mount (may not be exactly as shown) 1x ceiling arm 1x dome cover 1x ceiling tube 1x ring Amico Lights Corporation Installing Ceiling Mount Load data Bending moment MBmax. 210 Nm Vertical weight forces FG max. 205 N • 1x load only. Regional safety factors to be considered. • Maximum device load is assumed and included. Installing ceiling mount DANGER Mounting by qualified personnel • Mounting must be done by qualified personnel only. Lack of appropriate knowledge could be life-threatening. DANGER Life-threatening danger from falling luminaire. • The ceiling must be made of solid concrete to guarantee a secure hold. DANGER Electric shocks are life-threatening. • The electrical mains must be isolated from the by an external all-pole switch. 2 1 2 1 1. Loosen the mounting screw from the receptacle. 4. Remove the cotter pins (1) and mounting pins (2). 2 3 1 2. Using long-nose pliers, pull the receptacle with cable completely out of the ceiling tube at the inner ring. 5. Insert the ceiling tube (1) into the ceiling mounting (2) and drill with an Ø 10.5 mm bit (3). Use the existing bores of the ceiling mounting as a guide. 3. Cut the ceiling tube to the required length at the upper end using a metal saw and deburr the cut end. 6. Push the cable with receptacle into the ceiling tube again. www.amico.com 9 Installing Ceiling Mount 135 270 7. Align the threaded bore in the receptacle exactly with the existing bore in the ceiling tube. Fix with the mounting screw. 8. Secure the ceiling mount to the ceiling using the mounting holes provided, and the load data listed in on the previous page. Ensure 25 mm of clearance is present above the ceiling mount. DANGER Risk of injury from falling parts. • The ceiling bearing must be secured to the fastening material, that must be suitable for the corresponding ceiling condition. DANGER Risk of injury from falling parts. • Mounting must be performed by two people. CAUTION Use protective equipment in line with tool manufacturer’s instructions. 2 2 1 1 9. Pull the lamp cable from the ceiling tube through the mounting. Insert the ceiling tube into the mounting. Secure with the two mounting pins (1) and two cotter pins (2). 1 10. Tighten the four Allen screws in the mounting (1). DANGER Mortal danger from electric shock. • Disconnect or remove fuses before carrying out any work on the mains connection • The systems must be wired by a qualified electrician or someone with similar qualifications. 10 Amico Lights Corporation the light or surroundings may be damaged. The warning symbol is used with the following signal words as follows: WARNING WARNING May cause death or serious injury. May cause death or serious injury. Installing CeilingCAUTION Mount CAUTION May cause minor injury. May cause minor injury. Protective earth Protective earth Neutral conductor return line for current Neutral conductor return line for current Live conductor Live conductor 11. Connect to the main power supply. Disposal Disposal 1 13. Slide cover and ring over ceiling mount and tighten ring screws (1). Manufacturer Manufacturer 12. Connect the ceiling tube cable to the power harness (if power harnesses are installed). 4 4 www.amico.com 11 Installing Ceiling Arm WARNING Danger of injury from unfolding spring arm. 4 1 2 3 1. Gently pry the two halves of the cover apart and set aside. 4. First install washer (1), then safety washer (2), followed by two locking rings (3). Ensure tooth on safety washer aligns with the hole in the ceiling tube (4). 1 2 2 1 1 2 2. Remove two screws (1) from receptacle mount. Move receptacle mount (2) to provide access for mounting. 5. Replace the receptacle mount (1). Reinstall two screws (2), do not over tighten. 3. Install ceiling arm. 6. Gently replace covers and snap together WARNING Device may fall if inaccurately fastened. • Locking rings must click into groove and be evenly positioned all around. 7. To continue with installing the Lighthead see Installing the Lighthead section of this manual 12 Amico Lights Corporation Installing The Lighthead 1. Remove screw 4. Insert safety segment. 2. Rotate sleeve so the notch and slot are aligned. 5. Turn back sleeve and install the screw. Tighten screw according to requirements of the friction from the Lighthead. 3. Insert Lighthead. 6. Clip handle on. CAUTION Damage can be caused by falling Lighthead. • Danger of injury through incorrect fitting of the Lighthead. www.amico.com 13 Operation Mira LED Floorstand WARNING Danger of death from electric shock • Do not plug in a damaged power cable • Replace damaged power cable before using light again • The mains voltage and frequency must match the data on the name plate • Connect to a mains connection with a protective earth only. NOTICE: • Wind the power cable to the cable retainers when it is not being used. 2 1 1. Plug in cable (1). 2. Install the cable to the mains supply. 3. Switch on (2). Mira LED – All Models Switch on Light from control pad at Lighthead. Power (on/off ) Decrease brightness 14 Amico Lights Corporation Endo Light (on/off ) Increase brightness Disinfecting, Cleaning and Sterilization NOTICE: Damage due to improper cleaning • Do not use alcohol, solvent or cleaning agents containing chlorine or scouring agents. • Damage to lens by concentrated disinfectant or solvent. • Follow the manufacturers recommended mixing ratio. • Use of incorrect cloths may scratch lens. NOTICE A dirty lens will reduce the illuminating power. • Clean lens regularly • Spray and wipe disinfection is permitted. • Clean the lens with a leather cloth soaked in cleaner • Spray disinfectant in horizontal position. NOTICE The external components of the light can be disinfected with the following diluted products: • Lysoformin • Dismozon • Hexaquart plus • Sagrotan – fast disinfecting cleaner NOTICE The local government regulations for disinfection must also be observed in addition to these instructions. NOTICE Sterilize handle at 120⁰C and 1.05 bar for 30 minutes. www.amico.com 15 Maintenance DANGER Electric shocks are life-threatening. • Remove the connector from the power supply and put the switch in the “OFF” position. • The connector cable must be checked for damage at least once per year. NOTE • Maintenance and repairs must only be carried out by qualified electricians. • The corresponding user profile is described in Chapter 2, Safety instructions Setting Spring Force NOTE The spring force is set at the optimum setting in the factory • Lift the spring arm to its highest position. • Insert a 6 mm Allen key through window and turn the adjustment screw. Setting spring force: • Turn screw counter clockwise (+) to increase spring force (when spring arm lowers) • Turn screw clockwise (-) to decrease spring force (when spring arm rises) 16 Amico Lights Corporation Notes On The Arm Systems Selection Of Fastening Material We recommend the use of (not included in the delivery) counter-plates for fastening to drywall. Cleaning and disinfection DANGER Electric shocks are life-threatening. • The devices can conduct electricity and must be handled with care during cleaning and disinfection. • If there is a power plug remove it from the socket. • Do not use spraying methods for cleaning and/or disinfection. • Do not spray liquid into the openings of electrical power sockets, gas sockets or devices, or allow liquid to enter these. Recommended cleaning agents Use mild soap solutions or standard detergents as cleaning agents. Wipe down the surfaces of the equipment with a dampened cloth. If necessary, use small quantities of mild soap solution as a cleaning agent. Then wipe the outer surfaces with a soft, clean cloth until they are completely dry. Disinfection procedure Disinfection by wiping is intended to be the standard disinfection procedure for the support arm system. Hygiene guidelines and corresponding safety measures must be determined by the operator for the disinfection procedures that are applied. • After the contamination by any potentially infectious material (such as blood, secretions or excrement), the areas must be disinfected immediately in a targeted way. • Comply with application concentrations. • Wipe the area to be disinfected rather than spraying it. • Do not use areas that have been wiped until the disinfectant is dry. • Testing DANGER Electric shocks are life-threatening. • During all testing work, disconnect the device from the power supply/remove the plug from the power socket and secure the device so that it cannot be switched on again. Every 6 months or 5000 arm movements check for: • Paint damage • Cracks in plastic parts • Deformation of the support system • Loosening of parts Every 2 years: The securing element of the cantilever arm must be checked and greased by a qualified professional. www.amico.com 17 Notes On The Arm Systems Disassembling For Servicing DANGER Injury hazard • The cantilever arm is under a high spring load. If the end device is not moved to the upper cantilever arm position, the cantilever arm will spring up, possibly causing serious injury. Only remove the end device if the cantilever arm is in the upper position. • Disconnect the device from the power supply/remove the plug from the mains and ensure it cannot be switched on again. • Place cantilever arm in the upper position. • Unscrew the brake screw 1 so that the sleeve 2 can be turned. • Turn the sleeve 2 through 180 degrees until the securing segment 3 appears in the slot 4. • Hold the end device head 5 firmly and remove the securing segment 3 using a narrow flat-bladed screwdriver. • Remove end device 5 from the connection. • Put protective cap in place. 1. Brake screw 2. Sleeve 3. Securing segment 4. Slot 5. End device terminal This system is designed to be equipped with end devices from other manufacturers. For end device operation instructions please refer to the operating instructions of the related manufacturer. 18 Amico Lights Corporation al WARNING ENG Never unscrew the top cable retainer. Spare Parts Handle (Art.- Nr. D51.040.000) If both cable retainers are unscrewed, the connection will be loose and will fall, which may cause injury and damage to the cables 13 SPARE PARTS and lamp. Rotary knob (Art.- Nr. D51.050.000) ENG dispose of the light with the 12.113 Disposal SPARE PARTS fuse. Dispose oft he light at a centre or return it to a dealer not dispose of sposal serviceDodebending onthe light with the normal refuse. Dispose oft he light at a ulations. Cut offrecycling the cable centreflush or return it to a dealer ousing.HandleHandle with a disposal service debending on (Art.Nr. D51.040.000) (Art.- Nr. D51.040.000) Rotary knob (Art.- Nr. D51.050.000) Cable: Cable: • Cable: Schuko D70.017.000 Schuko D70.017.000 • CH Schuko D70.018.000 CH D70.018.000 D70.017.000 CH D70.018.000 UK D70.019.000 • UK D70.019.000 UK D70.019.000 US D70.020.000 US HG D70.020.000 • USHG HG D70.020.000 local regulations. Cut off the cable flush with the housing. Handle (Art.- Nr. D51.040.000) Rotary knob (Art.- Nr. D51.050.000) Fast-blow 1A fuse (Art.- Nr. D69.596.000) Rotary knob (Art.- Nr. D51.050.000) • triango Fast-blow 30 F 1A onlyfuse (Art.- Nr. D69.596.000) Mira LED Floorstand only Rotary knob (Art.- Nr. D51.050.000) Cable: Schuko CH UK US HG Fast-blow 1A fuse (Art.- Nr. D69.596.000) triango 30 F only D70.017.000 D70.018.000 D70.019.000 D70.020.000 Troubleshooting Cable: Schuko CH UK US HG D70.017.000 D70.018.000 D70.019.000 D70.020.000 Fast-blow 1A fuse (Art.- Nr. D69.596.000) Malfunction Possible triango 30 F only cause Remedy User profiles Light does not come on Contact fault Switch on again All Light does not come on Illuminant defective Contact manufacturer’s AfterSales Service Only by manufacturer’s AfterSales Service Check power supply and all connections Qualified electrician Replace fuse Qualified electrician Fast-blow 1A fuse (Art.- Nr. D69.596.000) Light does30 not come on triango F only Light does not come on No mains power 1A fuse defective (Mira LED Floorstand only) 19 www.amico.com 19 19 19 The warning symbol is used for all instructions that are important for safety. If warnings are ignored, users may be injured or the light or surroundings may be damaged. The warning symbol is used with the following signal words as follows: Disassembly WARNING May cause death or serious injury. CAUTION DANGER May cause injury. Electric shocks are minor life-threatening. • Remove connector from the power supply and put the switch in the “OFF” position before disassembling. Protective earth DANGER Never unscrew the upper cable holder - injury hazard. Neutral conductor return line for current • When both cable holders are unscrewed, the connecting piece is loose and falls downward, which could cause injury and/or damage to the cable and/or the device Live conductor Disposal Disposal Do not dispose of this product with normal refuse. Dispose of the product at a recycling center or return it to a dealer with a disposal service depending on local regulations. Cut off the cable flush with the housing. Manufacturer 4 20 Amico Lights Corporation Technical Data of the Lighthead Units Lighthead Diameter Mira 50 LED Mira 65 LED Mira 90 LED in 18 18 18 lx (fc) 50,000 Lux (4,762 fc) @ 1m (39.37") 65,000 Lux (6,190 fc) @ 1m (39.37") 90,000 Lux (8,571 fc) @ 1m (39.37") Brightness Control % 50-100 50-100 50-100 Light Field Diameter in 6.5-12.0 6.5-12.0 6.5-12.0 Depth of Illumination in 94.5 94.5 94.5 Color Rendering Index Ra 95 95 95 R9 in 90 90 90 Weight of Lighthead lbs 11 11 11 K 4500 4500 4500 Single Mask % 0.7 0.7 0.7 Double Mask % 55.5 55.5 55.5 Cavity % 100 100 100 Single Mask with Cavity % 0.3 0.3 0.3 Double Mask with Cavity % 55.3 55.3 55.3 36 36 36 Light Intensity (Central Luminance) Color Temperature (Standard) Shadow Dilution Number of LED's (Main) LED Service Life hours 50,000 50,000 50,000 Total Radiant Power at Max Intensity W/m² 178 231.4 317 100-240 VAC, 50/60 Hz, 0.40 amps 100-240 VAC, 50/60 Hz, 0.55 amps 100-240 VAC, 50/60 Hz, 0.65 amps Direct Power Supply Direct Power Supply Direct Power Supply Mounting Options Ceiling, Wall, Floorstand Ceiling, Wall, Floorstand Ceiling, Wall, Floorstand Certificates cETLus conform to UL60601-1; UL60601-2-41; UL certified IP54 per IEC 60598 cETLus conform to UL60601-1; UL60601-2-41; UL certified IP54 per IEC 60598 cETLus conform to UL60601-1; UL60601-2-41; UL certified IP54 per IEC 60598 Electrical Power Supply ea www.amico.com 21 Technical Data of the Arm System Electrical: Nominal input voltage100-240 VAC Frequency range 50 / 60Hz Input current4A-2A Device ProtectionClass 1 Approval ETL/cETL Environmental conditions for transport, storage and operation: Storage and transport After 15 weeks the conditions for operation apply. -10°C to +50°C Ambient 20% to 90% humidity 700hPa to 1060hPa Operation This product should be acclimatized to its operating conditions for 24 hours prior to its first use. +10°C to +40°C 30% to 75% humidity Weight: Maximum device load42Nm (375 in-lb) Mira LED Swing Floor Stand 11 kg (24 lbs) Mira LED Swing Ceiling Mount 10 kg (22 lbs) Operating mode: Operating modecontinuous operation Classification: Mira LED SwingClass I Classification under 93/42 EEC – Annex IX Class I (medical device class) Safety testing according to: CSA C22.2#60601-1 IEC/EN 60601-1 2nd. UL 60601-1 22 Amico Lights Corporation Warranty Policy - Lighting Products Amico Lights Corporation is warranted against defective materials and workmanship for twelve (12) months from the date of shipment. Within this period, Amico Lights Corporation will repair or replace any part on site or at the factory which is proven to be defective at Amico Lights Corporation cost. Furthermore, Amico Lights Corporation will warrant its material to be free from defect for an additional period of four (4) years (five [5] years from the date of shipment). Within this period, Amico Lights Corporation will replace any part which is proven to be defective, at no charge. Shipping and installation costs after the first twelve (12) months will be borne by the Customer. The Warranty applies to normal usage and does not apply to any product that has been subject to alteration, abuse, negligence or use (including voltage and/or current) other than that for which the product was designed. Amico Lights Corporation shall not be liable for incidental or consequential damages resulting from the use of the equipment. All claims for warranty must first be approved by Amico Lights Corporation. A valid Return Goods Authorization (RGA) number must be obtained from Amico Lights Corporation prior to commencement of any service work. Warranty work, which has not been pre-authorized by Amico Lights Corporation, will not be reimbursed. Amico Lights Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada 71 East Industry Court, Deer Park, NY 11729, USA Tel: 905.764.0800 | Fax: 905.764.0862 www.amico.com www.amico.com 23 www.amico.com Amico Lights Corporation | www.amico.com 85 Fulton Way, Richmond Hill Ontario, L4B 2N4, Canada Toll Free Tel: 1.877.264.2697 Toll Free Fax: 1.866.440.4986 Tel: 905.763.7778 Fax: 905.763.8587 Email: [email protected] LT-INSTALL-INSTR-MIRA-LED-CLNG 11.26.2015
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement