Altronix eBridge4PCRM is a versatile device that enables the transmission of data and power over coaxial cables, making it an ideal solution for upgrading analog CCTV systems to IP cameras while utilizing existing infrastructure. It allows for seamless integration of IP cameras into legacy analog systems, providing a cost-effective and efficient migration path.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
Altronix eBridge4PCRM Installation manual | Manualzz

Rev. 032113

Installation Guide

PLUS

eBridge4PCRM - IP and PoE+ over Coax Solution

Operates with eBridge1PCTX Transceiver.

Z1409

I.T.E. 43KC

Overview:

The eBridge4PCRM and eBridge1PCTX are CAT5 to Coax cable Ethernet adapters/Media converters that deliver data and power over the coax cable in a PoE+ compliant format. The paired set enables fast 10/100Base-T Ethernet digital communication to be transmitted over Coax cable. An eBridge4PCRM receiver is powered by a a UL Listed limited power source, PoE midspan or endspan product, such as a NetWay8M and NetWay16M and sends its power over the coax to the eBridge 1PCTX transmitter under PoE protocol. This enables the eBridge4PCRM to be used in a managed manner, allowing for remote camera reset. The eBridge1PCTX in turn delivers that PoE+ compliant power to a PoE enabled camera or

IP device. The eBridge4PCRM will not deliver power to non compliant devices, thus avoiding damage to improperly connected analog cameras. These plug and play units facilitate system upgrades from analog to IP cameras/devices utilizing existing legacy Coax and eliminating the costs and labor associated with installing new network cabling. In addition, data transmission and power over the Coax is possible up to 500m in comparison to 100m Ethernet maximum distance (see

Maximum Length of Coax Type vs. Camera Power/PoE Class, pg. 3). A maximum range from head end to the PoE camera/ device is 610m taking into consideration that up to 100m of structured cable may be deployed at each end.

Agency Listings:

• UL/CUL Listed for Information

Technology Equipment (UL 60950-1).

• CE approved.

• C-Tick compliant.

Input:

• Powered by a UL Listed limited power source,

PoE midspan or endspan.

Ethernet:

• Connectivity: RJ45, auto-crossover.

• Wire type: 4-pair CAT5 or better structured cable.

• Distance: up to 100m.

• Speed: 10/100BaseT, half/full duplex, auto negotiation.

PoE compliant to IEEE 802.3af (15W) and PoE+

compliant to IEEE 802.3at (30W) Delivered to

camera by eBridge1PCTX. Power provided by

eBridge4PCRM to eBridge1PCTX by PoE protocol.

• Throughput is rated to pass 25mbps of data at

distances up to 500m. With proper headend

equipment this supports Megapixel, HD720, HD1080.

Coax:

• Distance: up to 500m (see Maximum Length of Coax

Type vs. Camera Power/PoE Class, pg. 3) for power

delivery of coax.

• Connectivity: BNC, RG-59/U or similar.

LED Indicators:

• eBridge4PCRM:

Blue LED - Coax link connection.

Green - PoE ON.

Green - Power ON.

Features:

LED Indicators (cont’d):

• eBridge4PCRM and eBridge1PCTX:

Yellow and Green LED (RJ45) IP Link status,

10/100Base-T/active.

• eBridge1PCTX:

Blue LED - Coax link connection.

Green LED - PoE from eBridge4PCRM.

Environmental:

• Operating Temperature:

eBridge4PCRM: -- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

eBridge1PCTX: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

Storage Temperature: -- 22º to 158ºF (-- 30º to +70ºC).

• Humidity: 20 to 85%, non-condensing.

Functions:

• Auto detection and protection of legacy

non-PoE cameras/devices.

Applications:

• Retrofit digital IP cameras in an analog CCTV

installation.

• Works with Megapixel, HD720, HD1080 and VGA

(SD) cameras (see note, pg. 2).

• Extend Network link distance in an industrial

environment over 610m (see note, pg. 2).

• Upgrade deployed CCTV Coax to a digital network

in Retail, Hospitality, Arenas, Casinos, Airports,

Schools, Hospitals, Transportation, etc.

Mechanical:

• Dimensions (H x W x D approx.):

eBridge4PCRM:

1.7” x 5.25” x 9.25” (43.8mm x 133.35mm x 235mm)

eBridge1PCTX:

1” x 2.5” x 4.375” (25.4mm x 63.5mm x 111.125mm) eBridge4PCRM - 1 -

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.

eBridge1PCTX and eBridge4PCRM are not intended to be connected to outside plant leads and should be installed indoors within the protected premises. eBridge1PCTX and eBridge4PCRM are intended for indoor use only.

1. eBridge4PCRM installation:

Unit should be mounted in proximity to ethernet switch/network, NVR or video server.

Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [10/100BaseT]

(Fig. 2, pg. 3).

c. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 2).

2. eBridge1PCTX installation:

a. Secure unit to desired mounting surface with a proper fastening device utilizing the case’s mounting hole.

Unit should be mounted in proximity of camera/device.

b. Connect structured cable from IP camera/device to RJ45 jack marked [10/100BaseT] (Fig. 2, pg. 3).

c. Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).

Note: The eBridge4PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency. It is advisable to pre-test system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.

Fig. 1 eBridge4PCRM

Front Panel

Structured

Cable from midspan/endspan

Back Panel

Data In

- 2 -

Coax

Cable from eBridge1PCT or eBridge1PCTX

eBridge4PCRM

Fig. 2 eBridge1PCTX

Fig. 3

Green LED indicates

Power

Structured

Cable from

IP Camera/Device

Coax

Cable from eBridge4PCRM

Multiple PoE camera connection:

Blue LED indicates

Coax Connection

eBridge4PCRM

PoC (PoE+ over Coax)

500m max.

PoC (PoE+ over Coax)

500m max.

PoC (PoE+ over Coax)

500m max.

PoC (PoE+ over Coax)

500m max.

eBridge1PCTX PoE compliant

100m max.

PoE Camera eBridge1PCTX

PoE compliant

100m max.

PoE Camera eBridge1PCTX

PoE compliant

100m max.

PoE Camera eBridge1PCTX

PoE compliant

100m max.

PoE Camera

NetWay8M - Front Panel

+ PoE --

SHUTDOWN

Legend:

Coax

Structured Cable

Ethernet Switch

Local Area Network (LAN) or Laptop connection eBridge4PCRM - 3 -

Technical Specifications:

Parameter

Connections

Input power requirements

Description

BNC for Coax link. RJ45 for ethernet link.

Midspan or endspan port connected.

Indicators

Environmental

Conditions

Blue: Coax Link.

Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.

Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.

Green: Power.

Operating Ambient Temperature: UL60950-1

eBridge4PCRM: -- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

eBridge1PCTX: --- 4ºF to 120.2ºF (-- 20ºC to +49ºC).

Relative humidity: 20 to 85%, non-condensing.

Storage Temperature: -- 22º to 158ºF (-- 30º to +70ºC).

Operating Altitude: -- 1000 to 6,561.679 ft. (-- 304.8 to 2000m).

Regulatory

Compliance

UL/CUL Listed for Information Technology Equipment (UL 60950-1).

CE approved. C-Tick compliant.

Weights (approx.) Product: 1.35 lbs. (0.61 kg) Shipping: 1.7 lbs. (0.77 kg)

Camera

Power/

PoE Class

13W/0

4W/1

6.5W/2

13W/3

19W

25W

Maximum Length of Coax Type vs. Camera Power/PoE Class:

Coax Type

RG59/U - 23AWG RG59/U - 22AWG RG59/U - 20AWG RG59/U - 18AWG RG6/U - 18AWG

Max. Length (meters)

260.6

500

500

260.6

152.4

118.9

335.3

500

500

335.3

198.1

150.6

500

500

500

500

315.5

239.3

500

500

500

500

500

500

500

500

500

500

500

365.8

Shelf Installation

A

1 - Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 4).

2 - Place unit in desired location.

Fig. 4

B

Mounting Hardware

(Included):

Left Side

C Rubber Pad

Altronix is not responsible for any typographical errors.

140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.