Boiling Water Dispensers 283 Centrifugal Fans 257 Commercial

Boiling Water Dispensers 283 Centrifugal Fans 257 Commercial
HVAC
Boiling Water Dispensers Centrifugal Fans Commercial Fans Continuous Running Fans
Domestic Fans Easy Fit Electric Showers Economy 7 Controllers/
Immersion Heater Controllers Electric Radiators Electric Towel Rails Energy Efficient Hand Dryers Energy Efficient Storage Heaters Frost Protection Heaters Hand Dryers Immersion Heater Controllers
Installed Electric Heating Instantaneous Water Heaters Mechanical Extract Ventilation (MEV) Oil Filled Heaters & Bathroom Heaters Panel Heaters Plinth, Overdoor & Commercial Heaters Portable Heaters Room Thermostats/Digital Programmers Quiet Fans Storage Heaters Timeswitches Tubular Heaters Unvented Water Heaters/Flat Back Cisterns Vented Water Heaters Ventilation Accessories 283
257
260
256
258 - 259
279
277
269
275
263 - 264
267
274
265
277 - 278
266
280
255
272
270
273
271
276
256
268
278
274
282
281
261 - 262
What Type of Ventilation Do I Need?
New Build
New Build/Refurb?
Can a whole house ventilation
system be accommodated,
including associated ductwork?
NO
Refurb
Is energy efficiency
important?
YES
NO
YES
Does the property have
an air tightness of less
than 5M³h/M²?
YES
NO
MVHR
MEV
Continuous
multiple room
balanced
ventilation with
heat recovery
Continuous running extract fans
Intermittent extract fans
Continuous
running
axial fans
Continuous
running
centrifugal fans
100mm
or 150mm
Axial fans
Centrifugal
fans
In-line
fans
Continuous
multiple
room extract
ventilation
Suitable for any
room providing
silent & energy
efficient
ventilation
For moving
air over short
distances i.e.
through a
wall/window
(max 1.5M duct)
Where greater
pressure is
needed for
moving
air larger
distances i.e.
(up to 6M duct)
Where the
fan can be
concealed &
situated within
the ducting run
in a ceiling void
See page
255
See page
256
Energy efficient,
near silent fans
where greater
pressure is
needed i.e. for
moving air
larger distances
(up to 6M duct)
See page
257
See page
258
See page
257
See page
259
Legislation Summary
When selecting ventilation you can come across many terms and expressions used to promote certain products and systems
over others in relation to legislative compliance. It is often not clear what is needed or why and so the aim here is to explain and
simplify the most common terms used when ventilation is being specified.
Approved Document F
Also known as Part F or ADF. Part F is the legislation that outlines the ventilation requirements for both new build and existing
dwellings. If a product is described as Part F compliant then it meets the criteria set out in this legislation.
Approved Document L
Also known as Part L or ADL. This deals with the conservation of fuel and power - basically energy efficiency. Part L was updated in
2013 and stated energy efficiency targets for houses had to improve by 8%. Ventilation has to comply with a maximum energy use
called Specific Fan Power and these are set according to the type of ventilation being used.
Intermittent Extract Ventilation - no higher than 0.5 W/l/s
Continuous Extract Ventilation - no higher than 0.7 W/l/s
Continuous Supply Ventilation - no higher than 0.5 W/l/s
MVHR - no higher than 1.5 W/l/s
SAP
The Government’s Standard Assessment Procedure (SAP) is used for assessing the energy performance of dwellings and the
associated running costs and also CO² emissions. The calculation is based on the energy balance (energy running costs vs overall
energy efficiency) taking into account a range of factors that contribute to energy efficiency - ventilation is one of these factors.
How do all these things tie together and affect ventilation?
In its simplest form what is being outlined is:
• New builds and refurbs now have to meet various energy efficiency criteria as well as minimum standards of ventilation as laid
out by Government legislation (Part L & Part F respectively).
• The ventilation used can have a beneficial effect on your SAP rating and these are listed in the National Calculation Database.
254
|
Mechanical Extract Ventilation (MEV)
MEV
Whole house Mechanical Extract Ventilation (MEV) provides simultaneous ventilation of separate wet areas, kitchens and utility rooms in a house or flat, gathering wet polluted
air and discharging it into the atmosphere.
How Does It Work?
Usage
• Unit is centrally located - normally in a loft or a
cupboard.
• Extract vents are connected to the central unit
using ducting.
• Air is simultaneously extracted from wet rooms bathrooms, kitchens, en-suites, utilty rooms - up to
5 rooms simultaneously.
• Primarily used in domestic new build applications
due to the need to run long ducting runs, although
suitable for all types of domestic dwellings.
• Within the building regulations airtight houses are
considered to be those with leakage less than 5m³
per hour per square metre of external envelope.
New build houses with more than this would
benefit from MEV.
User Friendly Installation
Benefits
• Can be wall, ceiling or loft mounted for
convenience.
• Easy commissioning - each spigot has an auto air
volume regulator which controls the air volume
pressure regardless of duct length.
• Unit can be controlled via remote switch enabling
the user to select one of three fan speeds
depending on their particular requirements.
• Energy efficiency - Continuously runs at a very
low rate and uses considerably less energy than
having intermittent extractor fans in all the wet
rooms.
• Near silent running - Because they extract
continuously, they can do so at very low levels and
with the unit sited remotely, they are extremely
quiet.
Kit Contents
The NL8002 MEV unit includes the following accessories:
Spigots - room extracts
80mm inlets
80mm spigot covers
125mm inlet
125mm spigot cover
Qty
4
2
1
1
Spigots - exhaust to atmosphere
125mm inlet
NL8002
Performance
• Extract from up to 5 wet rooms simultaneously.
• Eliminates cross contamination due to continuous
operation.
• Low noise levels.
• 3 speed settings.
Order Code
Model No.
1052025552
NL8002
Qty
1
Low
Medium
High
Extract
Extract
performance performance Watts
M³/h
L/S
240
67
24
362
110
42
500
139
48
Description
Dimensions (mm)
HxLxD
Whole House Ventilation Unit
420 x 240 x 425
1050371030
1050371031
1050371032
1050371033
1050371029
1050371034
NL80028
NL80029
NL80030
NL80031
NL80027
NL80032
37
43
48
Price - Each
1 off
£248.09
Accessories for NL8002
Order Code Model No.
dB(A)
NL80028
Description
Diameter
(mm)
Flexible Ducting
Flexible Ducting
Internal Grille
Wall Kit*
Flexible PVC Ducting
Worm Drive Hose Clip
80
80
80
125
125
60-125
Length (M) Price - Each
1 off
6
£29.89
15
£33.98
£4.55
£15.87
6
£39.72
£4.92
*NL80031 125mm wall kit comprises of 1 x white grille and telescopic tube - 250mm extending to 450mm
2 YR
NL80031
For additional rigid & flexible ducting see page 261-262
HVAC |
255
Continuous Running/Quiet Fans
Follow these simple instructions for any Newlec continuous running axial or centrifugal filterless fan:
1. Install or retrofit any existing fan.
2. Set the trickle speed to 6l/s (suitable for bathrooms and ensuites) or 9l/s (suitable for kitchens and utility rooms).
Then enjoy all these benefits:
Virtually Silent Running
Energy Efficiency
Health Benefits
Flexibility
As low as 11dB(A).
One of the most efficient fans
available and is designed to work
within the homes natural heat loss.
No unnecessary heat is lost from
the property.
Reduces condensation, improves
indoor air quality and helps prevent
mould and damp.
Powerful performance and discreet,
slimline styling make it suitable for
any room in the house.
4" (100mm) Continuous Running Axial Fans
• Single fan for use in all applications - suitable for any room in the house.
• Continuous running extract fan - 6l/s or 9l/s trickle selectable on installation boost at 15l/s.
• Slimline flat front for discreet styling and also reduces dust and dirt build up.
• Reduces condensation and improves air quality.
• Designed to work within the homes natural heat loss.
Virtually
silent
operation
Order Code Model
No.
1051058542
1051058543
NLSAFT
NLSAFTH
Size
(mm)
100
100
5 YR
Extract Rate - l/s
Low High Boost
Trickle Trickle
6
6
9
9
Power Consumption (W)
Low High Boost
Trickle Trickle
15
15
2
2
3
3
Sound Level (dB(A)@3M)
Low High Boost
Trickle Trickle
4.7
4.7
11
11
16
16
25
25
Control Options
Pullcord
Timer
Humidistat
✔
✔
✔
✔
Price - Each
1 off
£100.06
£110.71
4" (100mm) Quiet Fans
One of the quietest intermittent fans available on the market today.
60%
quieter
• Over 60% quieter than standard intermittent fans - only 27dB(A).
• Low energy - only 4.8W.
• Part F and Part L compliant.
• Wall or ceiling mountable.
• Slimline, discreet design with a depth of only 22mm.
than standard
intermittent fans
2 YR
Control Options
Order Code
Model No.
1051058546
1051058547
NLQF
NLQFT
256
|
Size
(mm)
Extract Rate
l/s
Power
Consumption (W)
Sound Level
dB(A)@3M
Backdraught
Shutters
100
100
21
21
4.8
4.8
27
27
✔
✔
Timer
✔
Price - Each
1 off
£47.56
£57.17
Centrifugal Fans
4" (100mm) Continuous Running Centrifugal Filterless Fans
• A filterless centrifugal fan requiring no maintenance schedule.
• Suitable for ducted applications where higher pressures are required.
• Self-cleaning centrifugal impellor.
• SELV version available - suitable for bathroom zone 1 areas containing a
fixed bath or shower.
• Slimline profile compared to similar equivalent fans - only 90mm deep
or can be flush mounted with a depth of only 17mm.
Filterless
fan
3 YR
no maintenance
required
Order Code Model
No.
1051058544
1051058545
NLSCF
NLSCFSELV
Size
(mm)
Extract Rate - l/s
Low High Boost
Trickle Trickle
100
100
8
8
13
13
25
25
Power Consumption (W)
Low High Boost
Trickle Trickle
1.5
1.5
2.5
2.5
8
8
Control Options
Sound Level (dB(A)@3M)
Low High Boost
Trickle Trickle
11
11
16
16
Pullcord Timer Humidistat SELV Price - Each
1 off
✔
✔
✔
£127.45
✔
✔
✔
✔
£153.32
36
36
4" (100mm) Centrifugal Fans
With a specific fan power (SFP) of only 0.47, the Newlec centrifugal fan fully
complies with both current Part F and Part L legislation.
• Can be ceiling or wall mounted.
• Can be flush of surface mounted.
• Adjustable rear or side spigot for ease of installation.
• Backdraught shutters - prevents incoming draughts and heat escaping when
the fan is not in use.
2 YR
NL882N
SFP
0.47
Control Options
Order Code
Model No.
1051011034
1051011035
NL882N
NL882TN
Size
(mm)
100
100
Extract Rate Power Consumption Sound Level Backdraught
l/s
Wattage
dB(A) @ 3m
Shutters
20.8
20.8
12.4
12.4
36
36
✔
✔
Pull
Cord
Timer
✔
Humidistat
SELV
Price - Each
1 off
£52.03
£45.86
HVAC |
257
4" & 6" Domestic Fans
4" (100mm) intermittent extract fans are generally used for bathrooms, ensuites and toilets, with 6" (150mm) being used for kitchens and utilities where a higher rate of extraction
is required. They operate most efficiently when wall or ceiling mounted and extract polluted air directly out of the property i.e. no extra ducting is required. The Newlec range
of intermittent extract fans can be operated in one of four ways depending on the model selected.
No Additional Fan Controls
• Fan switches on or off remotely
through light switch or other
remote switch.
Timer
Pull Cord
• Timers will continue to run for a
predetermined amount of time
- usually between 2 and 20 minutes once the light has been switched off.
Humidistat
• Allows the fan to be operated
manually rather than being set to
turn on when the light switch is
turned on.
• This is a built-in adjustable sensor
that will switch the fan on/off
automatically when the humidity in
the room reaches a certain level.
Newlec fans come with a choice of shutter options dependent on the model:
No Shutters
Backdraught Shutters
Automatic Shutters
• Are plastic hinged flaps (also known as butterfly
shutters) fitted on to the discharge of extractor
fans which open when air is being extracted but do
not allow air from the outside to travel back in to
the property via the fan when not in operation.
• Low cost on intermittent fans.
• Continuous running fans.
• In-line fans.
• These are thermo-activated internal shutters
behind the interior grille of the fan which open
and close silently completely sealing the unit
when not in use to prevent any draughts, noise
ingress or heat loss.
4" (100mm) Standard Fans
• Ideal for bathrooms, ensuites and toilets.
• Can be wall or ceiling mounted.
• High quality ABS mouldings.
• SELV version available - suitable for zone 1 areas containing a
bath or a shower.
• CE marked and BEAB approved.
2 YR
Standard 4" Fans - No Shutters
NL880
Order Code Model
No.
Size
(mm)
1000009100 NL880
1000009101 NL880T
1000009103 NL880H
100
100
100
Control Options
Extract
Power
Sound
Shutters Pull Timer Humidistat SELV Price - Each
Rate Consumption Level
Cord
l/s
Wattage dB(A)@3m
1 off
24
16
32
£14.01
24
16
32
✔
£18.69
24
16
32
✔
✔
£37.94
Standard 4" Fans - Automatic Shutters
Order Code Model
No.
1050151418
1050151416
1050151417
1051058548
NL880PS
NL880TS
NL880HS
NL880SELV
Size
(mm)
100
100
100
100
Control Options
Extract
Power
Sound
Automatic Pull Timer Humidistat SELV Price - Each
Rate Consumption Level
l/s
Wattage dB(A)@3m Shutters Cord
1 off
24
20
32
✔
✔
£28.32
24
20
32
✔
✔
£32.38
24
20
32
✔
✔
✔
£49.12
24
20
32
✔
✔
✔
£51.95
6" (150mm) Standard Fans
• Ideal for kitchens and utilities where a higher rate of
extraction is required.
• High quality ABS moulding.
• SELV version available - suitable for zone 1 areas containing
a bath or shower.
• Suitable for panel, wall or ceiling mounting (pull cord
models should not be mounted on the ceiling).
• CE marked and GS approved.
2 YR
Standard 6" Fans
NL883
Order Code Model
No.
1000009108
1000009109
1050151419
1000009537
258
|
NL883
NL883S
NL883TS
NL883HS
Size
(mm)
150
150
150
150
Control Options
Extract
Power
Sound
Automatic Pull Timer Humidistat
Rate Consumption
Level
l/s
Wattage
dB(A)@3m Shutters Cord
68
25
45
68
30
45
✔
✔
68
30
45
✔
✔
68
30
45
✔
✔
Price - Each
1 off
£51.77
£79.48
£94.34
£123.29
4" Fans
4" (100mm) Low Profile Fans
Designed to be more aesthetically pleasing, the Newlec range of low profile fans
have a slim 22mm grille yet lose nothing in terms of performance or versatility.
• Can be wall or ceiling mounted for installation convenience.
• Backdraught shutters to prevent draughts.
• SELV version available - suitable for Zone 1 areas containing a fixed bath or shower.
2 YR
Order Code
Model No.
1051058550
1051058552
1051058553
NLLPF100TA
NLLPF100LVTA
NLLPF100LVTHA
Size
(mm)
Power
Extract Rate Consumption Sound Level
l/s
dB(A)@3M
(W)
100
100
100
25
25
25
14
14
14
38
38
38
Control Options
Backdraught Pullcord Timer Humidistat SELV
Shutters
✔
✔
✔
✔
✔
✔
✔
Finish
White
White
White
✔
✔
Price - Each
1 off
£24.24
£53.87
£69.73
4" (100mm) Shower Fan Kits
Ideal for use within shower enclosures, wet areas and en-suites, the Newlec shower
fan kits are easy to install and eliminate the risks of electric shocks as the fan is
situated remotely. Available with an overrun timer or an overrun timer with light.
Kits include:
• Fan.
• 1.5m flexible ducting.
• Internal and external grilles.
• Screws, plugs and cable ties.
• Light option includes 12V transformer and light kit.
2 YR
SFP
0.43
NLFLT3
4" Shower Fan Kits
Order Code
Model No.
1051011037
1051011038
NL881TN
NLFLT3
Size
(mm)
Extract Rate
l/s
100
100
23.6
23.6
Power Consumption Sound Level
Wattage
dB(A) @ 3m
15
15
Shutters
41
41
Control Options
Timer
Light
✔
✔
✔
Price - Each
1 off
£39.15
£76.29
4" (100mm) In-Line Mixed Flow Fans
The Newlec In-Line mixed flow fans offer two and a half times the pressure of a
conventional axial fan whilst also being dimensionally compact. This makes them
ideal for solving ventilation problems for ducted systems.
• Energy efficient and Part L compliant - SFP of only 0.4 at low speed and 0.37 at
high speed.
• High quality ball bearing long life motors.
• Ideal for ducted applications.
• IPX4 rated.
2 YR
NL8000
Order Code Model No.
1052025550
1052025551
NL8000
NL8001
Size
(mm)
Extract Rate l/s
High speed/low
speed
100
100
69/52
69/52
Power
Consumption
Wattage
25
25
Sound Level dB(A)
@ 3m High speed/
low speed
24/20
24/20
Control Options
Timer
✔
Price - Each
1 off
£105.98
£114.53
SFP
0.4
SFP
0.37
LOW SPEED
HIGH SPEED
HVAC |
259
Commercial Fans
In order to determine the right size fan for the commercial application required, you need to calculate the correct fan performance (M³/hr). To do this calculate the room
volume in cubic metres, i.e. length x breadth x height, and then multiply by the number of air changes required. For example a canteen is 10M wide by 6M long and 3M high,
the canteen is 180M³ (10 x 6 x 3) and requires 8 air changes - 180 x 8 = 1440 M³/hr extract performance required. Assuming the fan is wall mounted, then select a 12" wall fan.
Air Changes Required
Bathroom & Shower Rooms
Bedrooms
Cafes
Canteens
Cellars
Changing Rooms with Showers
Conference Rooms
Garages
Hairdressing Salons
Halls & Landings
Hospital Rooms
Laundries & Launderettes
Living & Other Domestic Rooms
Meeting Rooms
Offices
Restaurants & Bars
3
2
10
8
3
15
8
6
School Rooms
Shops
Sports Facilities
Store Room
Toilets - Domestic
Toilets - Public
Utility Rooms
Workshops
10
3
4
10
3
4
6
6
2
8
6
3
3
10
15
6
Commercial Fans
• Suitable for panel/wall mounting or window mounting with appropriate
window accessory kit.
• External 2 speed reversible on/off controller available (NLCOMFC).
• Motor fitted with thermal overload protection.
• CE marked in accordance with all the relevant EEC standards.
• IP44 rated.
NLCOMF12A
2 YR
NLCOMFC
Order Code
Model No.
Description
Size
(")
Extract Rate
(M³/hr)
Sound Level
dB(A) @ 3M
1050151361
1050151363
1050151367
1050151364
1050151368
1050151369
NLCOMF9F
NLCOMF9A
NLCOMF12A
NLWK9
NLWK12
NLCOMFC
Commercial Fan with Fixed Grille
Commercial Fan with Automatic Shutters
Commercial Fan with Automatic Shutters
Window Kit
Window Kit
2 Speed Reversible Controller
9
9
12
9
12
1015
1015
1630
52
52
54
Control Options
Auto Shutter
✔
✔
Price - Each
1 off
£290.60
£374.92
£613.19
£37.92
£53.35
£52.15
NEW
DALI OCCUPANCY SYSTEM
SEE PAGES 49 & 50
260
|
Quick and easy
set up DALI
lighting control
systems
Ventilation Accessories
Flat Channel and Accessories
NLFC2M
NLFCCLIP
NLFCEBM
NLFCCON
NLFCHB
NLFCVB
NL8016
NLFCAB
110mm x 54mm Accessories
Order Code Model No.
1050325791
1050325792
1050325793
1050325794
1050325795
1050325796
1050325797
1050325798
1 YR
NLFC2M
NLFCCLIP
NLFCCON
NLFCEBF
NLFCEBM
NLFCHB
NLFCVB
NLFCAD
NLFCEBF
NL8012
204mm x 60mm Accessories
Description
2M Flat Channel
Fixing Clip
Flat Connector
90˚ Elbow Female
90˚ Elbow Male
90˚ Horizontal Bend
90˚ Vertical Bend
Round to Horizontal
Diameter Price - Each
(mm)
1 off
100
100
100
£30.75
£3.89
£3.49
£7.15
£7.78
£7.43
£7.43
£7.32
Order Code Model No.
1052025537
1052025540
1052025541
1052025542
1052025538
1052025539
1052025543
NL8010
NL8013
NL8014
NL8015
NL8011
NL8012
NL8016
Description
1.5M Flat Channel
Fixing Clip
Flat Connector
90˚ Elbow Male
90˚ Horizontal Bend
90˚ Vertical Bend
Round to Horizontal
Diameter Price - Each
(mm)
1 off
100
125
£35.26
£10.63
£7.66
£16.35
£17.66
£12.41
£10.18
1 YR
HVAC |
261
Ventilation Accessories
PVC Flexible Ducting
1 YR
Order Code Model No.
NL870
1000009110
1050325789
1000009535
NL870
NL872
NL883D
Length
(M)
Diameter
Price - Each
1 off
3
15
3
4" (100mm)
4" (100mm)
6" (150mm)
£10.18
£46.58
£18.63
Colour
Diameter
Price - Each
1 off
White
Brown
White
Brown
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
£7.89
£7.89
£14.58
£14.58
Colour
Diameter
Price - Each
1 off
White
Brown
White
Brown
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
£7.89
£7.89
£14.58
£14.58
Colour
Diameter
Price - Each
1 off
White
Brown
White
Brown
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
£25.66
£25.66
£33.78
£32.18
Exterior Wall Grille
1 YR
NL877B
Order Code Model No.
NL871
1000009111
1050151547
1000009536
1000009599
NL871
NL871B
NL877
NL877B
Gravity Wall Grille
1 YR
NL883GB
Order Code Model No.
1000009533
1000009600
1000009534
1000009601
NL880G
NL880GB
NL883G
NL883GB
NL880G
Wall Venting Kit
1 YR
Order Code Model No.
1000009113
1050363045
1000009114
1050363046
NL873
NL873
NL873B
NL874
NL874B
Window Venting Kit
1 YR
NL875
262
|
Order Code Model No.
Diameter
Price - Each
1 off
1000009115
1000009116
4" (100mm)
6" (150mm)
£31.55
£48.35
NL875
NL876
Energy Efficient Hand Dryers
The Enhanced Capital Allowance (ECA) scheme defines energy efficient dryers as those that use less than 6.9kWh of electricity per 1000 standard cycles. All Newlec energy
efficient dryers meet this criteria with the 1.6kW fast dry hand dryer ranges being on the Energy Technology List (ETL) meaning they are eligible for the governments ECA scheme.
The ECA scheme provides businesses with enhanced tax relief for investments in equipment that meets their published energy saving criteria thereby providing an incentive to
invest in energy efficient equipment (see etl.decc.gov.uk for further details).
Choosing the most energy efficient dryer for your needs
Based on an assumption of electricity costs of £0.095 per kW/Hr, with the dryer being used for 200 dries a day for 300 days a year. The cost of using paper towels is based on
4000 paper towels.
Paper
Towels
2.4kW Hand &
Face Dryer
1.6kW Energy
Efficient Dryer
1.0kW Energy
Efficient Dryer
Cross Wind
Hand Dryer
Energy Cost
per Year
£510
£106.40
£32.40
£19.00
£20.58
kW per hour per
1000 drying cycles
N/A
16.7
5.4
3.3
3.6
ECA Eligible
N/A
NO
YES
NO
NO
1.6kW Energy Efficient Fast Dry Hand Dryers
• Automatic operation - reduces risk
of spreading germs.
• Motor thermal protection auto
resetting at 105°C.
• IPX1 rated.
• Class 1 Electrical Safety.
2 YR
Energy Saving Features
Save over
65%
• 12-14 second dry time - uses less
energy per dry.
• Low energy option on installation from 1.6kW down to 1.2kW for even
greater energy savings.
• Blue LED gives visible indication
of drying zone ensuring hands are
always in warm air stream.
• Eligible for ECA funding.
energy
vs conventional
2.4kW dryers
NL9000
NL9001
NL9002
Order Code
Model No.
1050363164
1050363165
1050363166
NL9000
NL9001
NL9002
Noise Level
(dBA) at 1M
Output
(kW)
Airflow Volume
m³/hr
IP Rating
78
78
78
1.6 - 1.2
1.6 - 1.2
1.6 - 1.2
116
116
116
IPX1
IPX1
IPX1
Dimensions (mm)
H
D
W
277
201
175
277
201
175
277
201
175
Finish
White
Stainless
Satin
Price - Each
1 off
£481.15
£518.91
£518.91
HVAC |
263
Energy Efficient Hand Dryers
1.0kW Energy Efficient Fast Dry Hand Dryers
• Automatic operation - reduces risk
of spreading germs.
• 60 seconds auto shut-off.
• Class 1 Electrical Safety.
• IPX1 rated.
• Steel 1.2mm epoxy coated cover extremely durable.
Energy Saving Features
Save over
80%
• 10-12 second dry time - uses less
energy per dry.
• Only 1kW rating - one of the lowest
power consumptions in the energy
efficient hand dryer market.
• Blue LED gives visible indication
of drying zone ensuring hands are
always in warm air stream.
energy
vs conventional
2.4kW dryers
2 YR
NL1KWFD
Order Code
Model No.
1051039964
NL1KWFD
Noise Level
(dBA) at 1M
Output
(kW)
Airflow Volume
m³/hr
IP Rating
78
1
113
IPX1
Dimensions (mm)
H
W
D
Finish
180
White
250
138.5
Price - Each
1 off
£371.14
Energy Efficient Jet Hand Dryer
The new Newlec jet dryer offers the ultimate in fast, hygienic and energy efficient
hand drying. Its robust construction means this dryer is suitable for nearly all
public places, including restaurants, pubs, office buildings, factories, supermarkets
and hospitals.
• Automatic operation - reduces
risk of spreading germs.
• Antibacterial coating on dryer
- prevents multiplication and
spreading of germs.
• Antibacterial HEPA dust filter kills 99.9% of germs.
• Removable drip tray for easy
maintenance.
• Blue LED gives visible indication
of drying zone ensuring hands
are always in warm air stream.
Energy Saving Features
• 10 second dry time - uses less
energy per dry
• Brushless lo-carbon long life DC
motor adjustable between 750W
- 2050W
• Adjustable heater element - from
1.3kW down to 900W for even
greater energy savings.
2 YR
Save over
80%
energy
vs conventional
2.4kW dryers
NLJETDRY
Order Code
Model No.
1051090935
NLJETDRY
264
|
Colour
Output
(kW)
Drying
Time
Airflow
Volume m/s
IP Rating
Silver
DC 750
10 seconds
95
IPX4
Dimensions (mm)
W
D
H
700
300
225
Price - Each
1 off
£878.69
Hand Dryers
Hand and Face Dryers
• Automatic non-contact operation - less opportunity of passing on germs.
• Dry time - 26 seconds approx.
• 2mm metal cover (NLA48A and NLA48CA).
• Die cast aluminium cover (NL9AHD).
2 YR
NL9AHD
Order Code
Model No.
1000009512
1050325785
1050325786
NL9AHD
NLA48A
NLA48CA
NLA48CA
NLA48A
Output
(kW)
Airflow Volume
m³/hr
IP Rating
2.6
2.4
2.4
275
345
345
IP24
IPX1
IPX1
Dimensions (mm)
W
D
H
264
275
177
248
284
202
248
284
202
Finish
Price - Each
1 off
£311.10
£414.86
£489.09
White (Alu)
White
Stainless
1.8kW Hand Dryer
• Automatic non-contact infrared operation - less opportunity of passing on germs.
• High powered 1.8kW output.
• Vandal resistant die cast aluminium casing.
• Stylish design.
• 25 second dry time (approx).
1 YR
NLAHD1.8
Order Code
Model No.
1051050520
NLAHD1.8
Output
(kW)
Airflow Volume
m³/hr
IP Rating
1.8
181
IPX1
Dimensions (mm)
H
W
D
263
245
245
Finish
White Metal
Price - Each
1 off
£183.35
1.5kW Hand Dryers
• Automatic operation - reduces risk of spreading germs.
• Class 1 Electrical Safety.
• Dry time 30 seconds (approx).
• ABS (polycarbonite) case - NLBHAA.
• Aluminium case - NLBHAM.
1 YR
NLBHAA
Order Code
Model No.
1050325782
1050325783
NLBHAA
NLBHAM
Output
(kW)
Airflow Volume
m³/hr
IP Rating
1.5
1.5
110
100
IP21
IP21
Dimensions (mm)
H
W
D
275
275
225
225
160
160
Finish
White (ABS)
White (Alu)
Price - Each
1 off
£156.72
£197.35
HVAC |
265
Installed Electric Heating
Electricity as the main heating source for a home has many advantages over other forms of heating and is set to increase in popularity over the coming years.
This is because electric heating:
• Is easy to install whether in a new build property or as a refurb - no pipework
to consider.
• Becoming increasingly energy efficient.
• Easily added to as a system - perfect for extensions, conservatories etc.
• Requires little to no ongoing maintenance.
• Controllability - can be controlled on a room by room basis or as a whole house
system. No other system can achieve this level of control.
• Is 100% efficient at the point of use.
• Extremely safe as does not burn fossil fuels - no potential CO risks or
requirements for flues.
Storage Heaters
Uses off peak electricity to store heat which is slowly released over the course of the day - efficient when a constant heat is required over long periods in a day.
Energy Efficient Storage Heaters
Highly sensitive thermostat accurrate to +/-0.1°C
combined with a smart charge control module
means these storage heaters can offer energy
savings of over 30% compared to traditional
manual models*
Combi Storage Heaters
A charge regulator automatically adjusts the
amount of energy stored backed up by a built in
convector heater that can provide completely
silent top up heating.
Automatic Storage Heaters
A charge regulator automatically adjusts the
amount of energy stored leading to significant
savings over standard manual storage heaters.
Over
30%
energy
savings*
See Page 267
See Page 268
See Page 268
Electric Radiators and Panel Heaters
Wall mounted heaters ideal for rooms that require heating for shorter periods of time during the day - particularly suited in rooms such as bedrooms, bathrooms,
kitchens, conservatories and other rooms where constant heat is not required.
Electric Radiators
An incredibly efficient thermostat accurate to within +/-0.1°C combines with an
energy optimiser which manages the flow of electricity to the radiator meaning
that electric radiators can offer energy savings of over 40% when compared to
traditional panel convectors.
Panel Convector Heaters
With a fast heat up time and powerful convection, panel heaters are ideal where
heat is required quickly in short bursts.
Over
40%
energy
savings*
See Page 269
See Page 270
*All energy savings are based on an assumption of £0.14 per kWh peak and £0.06 per kWh off peak electricity rates
266
|
Energy Efficient Storage Heaters
Newlec energy efficient storage heaters have been designed to be the most economical electric storage heating solution. They reduce energy consumption by over 30%
when compared to standard manual storage heaters.
• Direct replacement for standard storage heaters - simply replace existing heater with a Newlec energy efficient storage heater.
• Once installed simply set to automatic mode, set your required temperature and enjoy savings of over 30% compared to equivalent manual storage heaters.
Over
Easy Programming
30%
1.
energy saving*
when in auto
mode
1. Press the “mod” button to select the mode.
2.
• Electronic Smart Charge Control module.
- Monitors the room temperature and the energy
consumption of the heater.
- Automatically adjusts the charging and
consumption during the off peak period.
- Only stores required energy.
• Precision Thermostat - accurate to +/-0.1°C which
leads to increased energy savings.
• Integrated convector heater for back-up heat if
required.
• Five operating modes - suits any application and
lifestyle.
• Built in daily programmer - allows user to minimise
wasted heat when room is not in use.
2. Use the “+” and “-” keys to select the
desired temperature.
Guide to Electric Heating Costs - Storage Heaters
A test comparing energy efficient storage heaters with manual storage heaters was undertaken under the following conditions assuming informed user intervention on the
manual heater every three to four weeks - no user intervention in energy efficient storage heaters required.
kWh
Used
Cost
@ £0.06
Energy Efficient Storage Heater
1.3kW (NLEESH2)
76387
1.7kW Manual Storage
121088
£45.84
£72.65
Approx savings vs
manual storage
heaters
Approx savings vs
automatic storage
heaters*
37%
26%
Test Conditions
Room size - 3.5M x 3M, 2.4M (height).
Temperature - 07.00 - 23.00 21°C.
23.00 - 07.00 18°C.
Time period - 6 months
(September to February inclusive).
*An automatic or combination storage heater would be expected to save c.15% over a standard manual storage heater. This would still result in the energy efficient storage
heater offering approximately 26% energy savings (c.£61.75 running cost).
5 YR
Energy Efficient Storage Heaters
Order Code
Model No.
1051058538
1051058539
1051058540
1051058541
NLEESH1
NLEESH2
NLEESH3
NLEESH4
Input
Rating
(kW)
Convector
Max Output
Rating (kW)
Storage Charge
Acceptance - 7Hr
Continuous (kW)
No of
Bricks
Weight Inc
Bricks (kg)
0.98
1.3
1.95
2.6
0.45
0.6
0.9
1.2
6.8
9.1
13.6
18.2
4
8
12
16
59
77
112
147
Dimensions (mm)
H
W
D
730
550
180
730
660
180
730
890
180
730
1110
180
Price - Each
1 off
£452.55
£553.97
£713.15
£840.40
For energy efficient storage heater sizing charts see page 336-337
* All energy savings are based on an assumption of £0.14 per kWh peak and £0.06 per kWh off peak electricity rates.
HVAC |
267
Storage Heaters
Storage
Heaters
Storage Heaters
Storage heaters are specifically designed to operate using cheaper off-peak electricity to store heat. When the off-peak period finishes the heat is gradually released into the
room over the course of the day. All Newlec storage heaters have the following benefits:
• Willow white colour.
• Drip proof (IPX2 rated).
• Automatic charge regulator - automatically adjusts the level of input charge
to compensate for changing weather conditions without user intervention.
• Manual reset thermal cut-out.
• Compatible with all off-peak tariffs.
Room
temperature
boost control
increases heat
output when
required
NL10658
Two types of storage heaters are available, each with their own benefits:
Automatic Storage Heaters
Combination Storage Heaters
• Thermostats have an automatic charge regulator. This measures the temperature in
the room and automatically adjusts the charge regulator accordingly. This can lead
to significant running cost savings over manual storage heaters.
All the benefits of an automatic storage heater plus the added advantage of having a built
in convector heater - essentially offering two heaters in one compact space. Benefits of
this include:
• Convector supplies completely silent top up heating.
• Convector thermostat can be set to maintain constant room temperatures and
automatically switch on as necessary.
• Can provide top up heat even if no heat has been stored overnight - particularly
useful in summer months if there is a sudden cold spell.
2 YR
Automatic Storage Heaters
Order Code
Model No.
1051061831
1051011765
1051011766
1051011767
NLASH0.8
NL10579
NL10580
NL10581
Input Rating
(kW)
0.85
1.7
2.55
3.4
Storage Charge
Acceptance - 7Hr
Continuous (kW)
6
12
18
24
No. of
Elements
No. of
Bricks
Weight Inc
Bricks (kg)
1
2
3
4
4
8
12
16
41
77
110
145
Dimensions (mm)
H
W
D
700
700
700
700
332
560
788
1016
170
170
170
170
1 YR
Combination Storage Heaters
Order Code Model No.
1050371283
1050371284
1050371285
268
NL10657
NL10658
NL10659
|
Price - Each
1 off
£259.68
£339.68
£428.26
£518.49
Convector Max Storage Charge
Input Rating Output Rating Acceptance - 7Hr
(kW)
Continuous (kW)
(kW)
1.7
1
12
2.55
1.5
18
3.4
2
24
No. of
Elements
No. of
Bricks
Weight Inc
Bricks (kg)
2
3
4
8
12
16
77
111
146
Dimensions (mm)
H
W
D
700
700
700
560
788
1016
204
204
204
Price - Each
1 off
£489.99
£633.63
£776.91
Electric Radiators
Electric radiators are a real innovation in cost effective electric heating. They provide central heating that can be controlled room by room, hour by hour to perfectly suit
the users requirements.
• Direct replacement for both panel convector and storage heaters.
• Electronic energy optimiser - restricts flow of electricity to the radiator meaning on
average a 1.5kW heater uses only 0.63kW of electricity to maintain constant room
temperature leading to increased energy savings.
• Three operating modes - Comfort, Economy and Frost protection.
• Quick-fix wall mounting brackets - save up to 50% on install time.
• Environmentally friendly fluid filled aluminium fins means that the heat is
transferred quickly and evenly into the room via both radiation and convection.
Offers
total control
room by room
with built-in
daily/weekly
programmer
Highly Accurate Thermostat
The more accurate the thermostat then the more efficient the heater. Newlec electric
radiators and Energy Efficiency Storage Heaters are accurate to +/-0.1°C giving the
following energy savings vs less accurate thermostats.
• Thermostat with +/-0.3°C uses up to 4.8% extra energy.
• Thermostat with +/-0.5°C uses up to 8% extra energy.
• Thermostat with +/-1.0°C uses up to 16% extra energy.
5 YR
Guide to Electric Heating Costs - Electric Radiators vs Panel Heaters
The following table is a guide to costs based on a required temperature of 21°C, ceiling height of 2.4mtrs and ‘U’ values,
ext.walls 1.5, floors 0.75, roof insulation 0.31 and glazed areas 2.9. The exact heater required would depend on the room
size that needed to be heated. For a more accurate guide we would require more information, including actual “U” values.
Please contact us to help you select and size your radiators accurately.
All costs are based on an assumption of £0.14 per Kwh peak and £0.06 per Kwh off peak electricity rates.
For more detailed sizing guides for all our heaters please see pages 336-337.
Heater
Model
Heater Type
Rating
(Kilowatts)
Approximate Running
Costs per Hour
NLHRADD500
NLHRADD750
NLHRADD1000
NLHRADD1250
NLHRADD1500
NLHRADD2000
Electric Radiator
Electric Radiator
Electric Radiator
Electric Radiator
Electric Radiator
Electric Radiator
0.5
0.75
1
1.25
1.5
2
£0.03
£0.04
£0.06
£0.07
£0.09
£0.12
Order Code
1051058532
1051058533
1051058534
1051058535
1051058536
1051058537
Model No.
NLHRADD500
NLHRADD750
NLHRADD1000
NLHRADD1250
NLHRADD1500
NLHRADD2000
Output
(kW)
Controls
0.5
0.75
1
1.25
1.5
2
Digital
Digital
Digital
Digital
Digital
Digital
Typical
energy savings
40%
Heater
Model
Heater Type
Rating
(Kilowatts)
Approximate Running
Costs per Hour
NLPH750
Panel Heater
0.75
£0.07
NLPH1250
NLPH1500
NLPH2000
NLPH3000
Panel Heater
Panel Heater
Panel Heater
Panel Heater
1.25
1.5
2
3
£0.12
£0.15
£0.20
£0.29
No of
Elements
Weight
(kg)
4
6
8
10
12
14
8
11
13.5
16
19
22
H
580
580
580
580
580
580
Dimensions (mm)
W
D
415
100
575
100
735
100
895
100
1055
100
1215
100
Price - Each
1 off
£277.50
£346.86
£393.12
£462.48
£508.74
£578.12
For electric radiator sizing charts see page 336
HVAC |
269
Panel Heaters
Panel Heaters
The slimline range of Newlec panel heaters are ideal for rooms that require rapid heat for short periods of time during the day e.g. bedrooms, bathrooms and conservatories.
IPX4
rated for use
in bathrooms
and other
wet areas
• Willow white to match Newlec storage heaters.
• Temperature settings from 35°C down to a frost protection setting (5°C).
• Thermostat accurate to +/-1.5°C.
• Detachable hinged wall mounting frame for fast installation and easy cleaning.
• Available in thermostatic or 24hr timer variants.
24 Hour Timer Thermostatic Panel Heaters
• 24 hour programmable timer.
• Timer can be set to switch on and off as often as required throughout the day
(in 20 minute intervals).
• Override switch enables the timer to be by-passed without altering the pre-set
programme.
Thermostatic Panel Heaters
• Highly accurate adjustable thermostat.
• Suitable for domestic or commercial use.
2 YR
NLPH750
Order Code
Model No.
1050335059
1050335060
1050335061
1050335062
1050363032
NLPH750
NLPH1250
NLPH1500
NLPH2000
NLPH3000
Loading
(kW)
Weight
(kg)
0.75
1.25
1.5
2
3
6.2
6.6
6.6
8
10
Dimensions (mm)
H
W
D
430
430
430
430
430
620
690
690
860
860
108
108
108
108
143
Price - Each
1 off
£94.35
£104.67
£115.12
£120.63
£162.41
24 Hour Timer Thermostatic Panel Heaters
• 24 hour programmable timer.
• Timer can be set to switch on and off as often as required throughout the day (in 20
minute intervals).
• Override switch enables the timer to be by-passed without altering the pre-set
programme.
2 YR
Order Code
Model No.
Loading
(kW)
Weight
(kg)
1050335063
1050335064
1050335065
1050335066
1050363033
NLPH750T
NLPH1250T
NLPH1500T
NLPH2000T
NLPH3000T
0.75
1.25
1.5
2
3
6.2
6.6
6.6
8
10
NLPH750T
For panel heater sizing charts see page 337
270
|
Dimensions (mm)
H
W
D
430
430
430
430
430
620
690
690
860
860
108
108
108
108
143
Price - Each
1 off
£120.86
£131.76
£142.23
£142.79
£193.07
Portable Heaters
Fan Heaters
Model No.
Dimensions (mm)
H
W
D
NLFH2KW
NL202
150
112
265
215
260
192
Order Code Model No.
1051039961
1000009542
NL202
NLFH2KW
1 YR
NLFH2KW
NL202
Loading
(kW)
Price - Each
1 off
2
2
£16.63
£25.87
• 2.0kW maximum output.
• 2 heat settings (1.0kW/2.0kW) and cool blow.
• Thermostat.
• Auto re-set thermal cut-out and safety fused
units.
• Thermostatic control with frost protection.
• Choice of heat settings including cool blow.
• Mains on neon indicator.
• Manual reset cut-out and safety fused link.
• BEAB approved.
2kW Convector Heater
• 3 heat settings - 0.75kW, 1.25kW and 2kW.
• Silent operation.
• Thermostatic control.
• Safety thermal cut-out.
• BEAB approved.
Model No.
Dimensions (mm)
H
W
D
NLCH2KW
370
530
Order Code Model No.
1051039978
NLCH2KW
110
Loading
(kW)
Price - Each
1 off
2
£17.29
NLCH2KW
1 YR
Convector Heaters
NLH1000A
NLH1001A
Standard
• White with grey trim.
• Thermostatic control and twin heat settings.
• Frost protection feature.
• Supplied with feet, wall brackets, cable and fitted plug.
• Overheat protection.
Timer Option
• As standard but with a 24 hour programmable timer.
Dimensions (mm)
H
W
D
Order Code
Model No.
NLH1000A
NLH1001A
NLH1002A
NLH1003A
420
420
420
420
1051091528
1051091529
1051091530
1051091531
NLH1000A
NLH1001A
NLH1002A
NLH1003A
200
200
200
200
Turbo Option
• As standard but with a turbo fan boost for extra heat
when required.
1 YR
Model No.
575
575
575
695
NLH1002A
Loading
(kW)
Thermostat &
Heat Selection
Timer
Turbo
Weight
(kg)
2
2
2
3
✔
✔
✔
✔
✘
✔
✘
✘
✘
✘
✔
✘
3.6
3.7
3.9
4.2
Price - Each
1 off
£39.18
£66.99
£68.62
£53.02
Dimensions including feet
HVAC |
271
Oil Filled Heaters & Bathroom Heaters
Oil Filled Column
• White/light grey colour.
• Thermostatically controlled.
• Frost protection.
• Auto reset safety cut-out.
1 YR
Model No.
Dimensions (mm)
H
W
D
NLOFCR
650
Order Code Model No.
NLOFCR
1050151441
NLOFCR
405
160
Loading
(kW)
Heat
Settings
1.5
2
Weight Price - Each
(kg)
1 off
10
£67.06
Oil Filled Radiator
• Willow white colour.
• Thermostatic control.
• Ideal for background or full heating.
• Free standing or wall mounted.
• Electrical reset safety cut-out.
1 YR
Model No.
Dimensions (mm)
H
W
D
NLH2000
648
1084
230
Dimensions including feet
NLH2000
Order Code Model No.
1052025187
NLH2000
Loading
(kW)
Heat
Settings
1.5
Variable
Weight Price - Each
(kg)
1 off
17.8
£191.84
Bathroom Heater
• Pullcord.
• 2kW maximum output.
• 1kW output selectable on installation.
• Energy saving thermostat – switches to 1kW
setting when room is warm (functions on 2kW
setting only).
• Visual ON/OFF indicator.
• Designed for high level mounting.
• IPX2 rated.
1 YR
NLBDHN
Model No.
Dimensions (mm)
H
W
D
NLBDHN
242
Order Code Model No.
1050184587
272
|
NLBDHN
229
109
IP Rating
Price - Each
1 off
IPX2
£45.61
Plinth, Overdoor & Commercial Heaters
Plinth Heater
• Supplied with three fascias - brown, white
and stainless steel.
• Pressed steel construction.
• Three output settings - 800W, 1600W
and 2400W.
• Thermostatically controlled with thermal
cut-out.
• Pre-wired with 1.5M mains lead.
1 YR
NLPH24KW
Model No.
Dimensions (mm)
H
W
D
NLPH24KW
125
480
Order Code Model No.
1050390629
200
Loading
(kW)
Heat
Settings
Price - Each
1 off
2.4
3
£91.18
NLPH24KW
Overdoor Heater
• 3kW heat output.
• 1.5kW half heat setting.
• Cool blow function.
• Durable steel case.
• Wall or ceiling installation.
• Bracket included.
1 YR
Model No.
Dimensions (mm)
H
L
D
NL3ACN
201
557
NL3ACN
100
Order Code Model No.
Element
Type
Supply
Voltage (V)
Thermal
Cut-Out
Airflow
(m/s)
Noise Level
dB(A) @ 1M
Price - Each
1 off
1051011600
Wire Strung
230 - 240
Manual Reset
6.2
50.5 (Full Load)
£176.76
NL3ACN
Commercial Fan Heater
Powerful commercial wall mounted heater with air circulation facility for summer use.
• 3kW power.
• Polycarbonate cased body.
• Nichrome wire heating elements.
• Multi directional wall bracket.
• Frost protection setting.
1 YR
Model No.
Dimensions (mm)
H
L
D
NL10
370
267
370*
*On full tilt
NL10
Order Code Model No.
1000008148
NL10
Output
(kW)
Airflow
(l/s)
Price - Each
1 off
3
83
£151.63
HVAC |
273
Frost Protection & Tubular Heaters
500W Frost Protection Fan Heater
Compact durable heater for use in a wide range of applications providing
low level localised heat frost protection.
• 500W output.
• Thermostat.
• Frost protection.
• Mains neon indicator.
• Overheat protection.
• Free standing or wall mounted (can be used either
horizontally or vertically when floor mounted).
1 YR
NLH5MPH
Model No.
Dimensions (mm)
H
L
D
NL5MPH
330
255
Order Code Model No.
1050152359
NL5MPH
150
Elements
Type
Wattage
(W)
Price - Each
1 off
Mineral Filled
500
£77.70
Thermostatic Tubular Heaters and Guards
• A new range of energy efficient tubular heaters to provide ambient and frost
protection heating for numerous applications including airing cupboards,
greenhouses, shop windows, conservatories, garages and shed.
• Provides low-cost heating with a built-in thermostat that keeps energy usage
to a minimum.
• Discreet mounting brackets included - suitable for walls or floors.
• Reversible left or right hand cable entry.
• IPX4 rated.
• Available in six sizes - from 1' to 6' to suit any application.
1 YR
NLTTH1
NLTTH2
NLTTH6
NLTTH4
Order Code
Model No.
1051058518
1051058519
1051058521
1051058523
NLTTH1
NLTTH2
NLTTH4
NLTTH6
Size
(feet)
Output
(W)
1
2
4
6
40
80
160
240
Dimensions (mm)
H
W
D
81
408
80
81
713
80
81
1323
80
81
1933
80
Price - Each
1 off
£15.13
£26.14
£35.46
£49.14
Tubular Heater Guards
• Welded wire guards to protect heaters from damage caused by vandalism,
interference or accidents.
• Available for 2', 4' and 6' heaters.
• Electro galvanised to BS 1706 ZN3.
NLWG21
Order Code Model No.
1050150546
1050150547
1050150548
274
|
NLWG19
NLWG20
NLWG21
Size
(ft)
Finish
Dimensions
(inches)
2
4
6
Galvanised
Galvanised
Galvanised
29 x 6 x 6
53 x 6 x 6
74 x 6 x 6
Price - Each
1 off
£58.07
£89.23
£116.58
Electric Towel Rails
The new range of Newlec electric towel rails come in a variety of stylish designs and a choice of heat outputs. Both white and chrome finishes are available with a variety of
heat outputs matched to the size of the rail.
S-Shaped Electric Towel Rails
• IPX4 rated.
• Rapid heat up.
• Lightweight and easy to install.
• Robust mounting brackets included.
1 YR
NLSWH80W
Order Code Model No. Output Dimensions
(W) H x W (mm)
Design
Finish
1051039951
1051039952
S-Shaped
S-Shaped
White
Chrome
NLSWH80W
NLSCH50W
80
50
645 x 500
645 x 500
NLSCH50W
Price - Each
1 off
£45.36
£64.44
Ladder Style Electric Towel Rails
• Steel construction with high quality white and chrome finishes.
• IP55 rated.
• Wall fixings and comprehensive step by step fitting instructions included.
• Plug and vent included.
• Heating element included.
1 YR
Order Code Model No. Output Dimensions
(W) H x W (mm)
Design
Finish
1051039954
1051039953
1051039955
1051039956
1051039957
Flat
Flat
Flat
Flat
Curved
White
Chrome
Chrome
Chrome
Chrome
NLFWH250W
NLFCH150W
NLFCH250W
NLFCH400W
NLCCH250W
250
150
250
400
250
1100 x 500
700 x 400
1100 x 500
1500 x 500
1100 x 500
Price - Each
1 off
£145.96
£156.91
£201.39
£283.08
£206.51
NLFCH150W
NLFWH250W
NLCCH250W
Electric Towel Rail Controllers
• IPX4 rated.
• White or chrome finish.
• Five power settings.
• Eco timer function.
2 YR
Order Code
1051039959
1051039960
Model No.
NLWHCON
NLCHCON
Finish
White
Chrome
Price - Each
1 off
£69.22
£94.21
NLWHCON
NLCHCON
HVAC |
275
Room Thermostats/Digital Programmers
Electronic Room Thermostat
• Easily adjustable dial with clearly marked scale.
• 5˚C to 30˚C temperature range.
• Surface mount with wall plate included.
• Temperature swing adjustable (using jumper) between 1˚C and 0.5˚C.
• 3 Wire connection (double insulated).
3 YR
NLBRT1
Order Code Model No.
1050378520
NLBRT1
Description
Load
Rating*
Electronic Room Thermostat
6A (2A)
Price - Each
1 off
£22.18
*Resistive load rating - inductive load rating in brackets.
7 Day Programmable Room Thermostat
• 7 day time and temperature programming with digital accuracy.
• 10°C to 30°C temperature range adjustable in 0.5°C steps.
• 6 different time/temperature periods.
• Automatic summer/winter changeover with frost protection.
• Easy +/- illuminated push button setting.
3 YR
NL1CHDPT1
Order Code Model No.
1050378522
NL1CHDPT1
Description
Load
Rating*
7 Day Programmable Room Thermostat 3A (1A)
Price - Each
1 off
£56.95
*Resistive load rating - inductive load rating in brackets.
7 Day Digital Central Heating and Hot Water Programmers
NL2CHDPT1
NL7DDPT1
• Single channel 7 day programming for use with room thermostats.
• 1 - 9 hour boost facility for instant control.
• 3 different time/temperature periods (5 day plus 2 or 7 day programming).
• Automatic summer/winter changeover and holiday mode setting.
• Factory fitted battery for memory back-up - remembers settings even after
a power cut.
All the benefits of NL7DDPT1 PLUS
• Two channel digital heating programmer - allows independent control of central
heating and hot water.
• Suitable for pump and gravity fed systems.
• Heat/hot water symbol displays on call for heat/water.
3 YR
3 YR
Order Code Model No.
1050378521
1050378523
Description
Load Rating Price - Each
@ 230V*
1 off
NL7DDPT1 7 Day Programmable Room Thermostat 3A (1A)
£53.18
NL2CHDPT1 2 Channel 7 Day Digital Programmer
3A (1A)
£56.95
*Resistive load rating - inductive load rating in brackets.
276
|
Economy 7 Controllers/Immersion Heater Controllers
Economy 7 Timeswitches
NLTRT7DM
NLTRT7DD
All the benefits of NLTRT7DM PLUS
• Digital accuracy improves system efficiency and reduces running costs.
• Accommodates up to 3 off-peak hot water or heating periods every 24 hours.
• Pre-selected timing options - manually adjustable to allow customised
programming.
• Easy view 12 hour am/pm clock/timer display illuminates on setting.
• Simple push button setting and select modes with full screen information.
• Designed for use with Economy 7 off peak rate overnight electricity plans.
• 24hr segment time setting dial with 15 minute switching intervals for customised
programming.
• Completely interchangeable with previous Newlec models as well as Horstmann
and Sangamo Economy 7 units.
• Fits and supplied with a standard size Economy 7 wall box with industry standard
plug-in connections.
• 4 Boost demand options – 15, 30 minutes, 1 and 2 hours.
Order Code Model No.
1051024051
1051024052
NLTRT7DM
NLTRT7DD
Description
Economy 7 Analogue Timeswitch
Economy 7 Digital Timeswitch
Price - Each
1 off
£106.92
£106.92
3 YR
24 Hour Immersion Heater Time Controller
• Specially designed for installation with both new and existing immersion
heater systems.
• Up to 24 ON & OFF programmes (additional pins required).
• Bottom or rear entry for cable.
3 YR
Order Code Model No.
1050378529
NL24HRIHTS1
Description
Load
Rating*
24 Hour Segment Immersion Heater Controller
13A (5A)
Price - Each
1 off
£30.23
NL24HRIHTS1
* Resistive load rating - Inductive load rating in brackets
24 Hour Immersion Heater Timeswitches
• 96 quick-set segments for up to 48 ON/48 OFF programmes.
• Red LED ‘Mains ON’ and green LED ‘Output’ indicators for easy viewing.
• Special ‘Traffic Light’ slider switch for easy ON (green), Auto (green & red) and
OFF (red) mode indication.
• NL24HRIHTS fits a standard flush or surface mount box min. 32mm deep.
• NL24HRTS is slimline and switches up to 750W incandescent or halogen
lighting/750W fluorescent lighting/100W compact fluorescent lighting
(not suitable for discharge lighting).
3 YR
NL24HRIHTS
Order Code Model No.
1051040108
1051040110
NL24HRIHTS
NL24HRTS
Description
Load
Rating*
24 Hour Compact Immersion Heater Timeswitch
24 Hour Slimline General Purpose Timeswitch
16A (6A)
16A (6A)
Price - Each
1 off
£38.46
£41.66
NL24HRTS
* Resistive load rating - Inductive load rating in brackets
HVAC |
277
Immersion Heater Controllers/General Purpose Timeswitch
7 Day Electronic Immersion Heater Timeswitch
• 4 ON/4 OFF easy-set programme periods per day, 28 ON/28 OFF programmes
per week.
• Extra large ‘Easy View’ screen with blue LED backlighting.
• Optional 1 and 2 hour boost button..
• Automatic Summer/Winter changeover
• NL24HR7DIHTS fits a standard flush or surface mount box min. 32mm deep.
3 YR
NL24HR7DIHTS
Order Code Model No.
NL24HR7DELTS
1051040109
1051040111
NL24HR7DIHTS
NL24HR7DELTS
Description
Load
Rating*
7 Day Electronic Compact Immersion Heater Timeswitch
7 Day Electronic Slimline General Purpose Timeswitch
16(4)A
16(4)A
Price - Each
1 off
£60.83
£67.21
* Resistive load rating - Inductive load rating in brackets
2 Hour General Purpose Boost Timer
• Boost timer for immersion heaters, room heaters, towel rails etc.
• Automatically switches off at end of set time period.
• ON time can be increased in four step - 15, 30, 60 or 120 minutes.
3 YR
Order Code Model No.
NL2HRBT1
1050378519
NL2HRBT1
Description
Load
Rating*
2 Hour Boost Timer
13A (3kW)
Price - Each
1 off
£36.52
Fused Spur Timeswitches
• Easy view 24 hour digital clock/timer display.
• Optional 1 or 2 hour boost facility.
• Integral memory backup battery retains programmes in event of power
failure.
• Suitable for use with up to 3kW immersion heaters.
• Switches the following lighting loads: 750W incandescent or halogen
lighting, 500W fluorescent lighting, 100W compact fluorescent lighting
(CFL’s) and 200W LED lighting. Not suitable for discharge lighting.
3 YR
NLFST1
NLFST2
Order Code
Model No.
1051058516
1051058517
NLFST1
NLFST2
Description
24 Hour Fused Spur Timeswitch
7 Day Fused Spur Timeswitch
Price - Each
1 off
£70.61
£77.32
Plug-In Time Controllers
• Plug-in controllers to switch appliances on/off at preset times.
• Compact design.
• Suitable for 13A (3kW) appliances, filament lamps up to 400W
and 100W low energy/fluorescent lighting.
• Up to 24 on/off programmes per day (NL24HRST1).
• Up to 20 on/off programmes selectable over individual days.
3 YR
NL24HRST1
278
NL24HR7DDTS1
|
Order Code
Model No.
1050378517
1050378518
NL24HRST1
NL24HR7DDTS1
Price - Each
1 off
£11.66
£16.06
Easy Fit Electric Showers
Easy Fit Electric Shower
• 8 water connection options - allowing for pipe entry from top, bottom, side or rear of
the shower.
• 3 cable entry options - allowing for cable entry from top, bottom or rear from the right
hand side of the shower.
• Full accessory kit including easy rub-clean single mode shower head and soap dish.
• Large footprint covers most other electric showers - less likelihood of having to alter
existing tiling or decoration.
• Improved working space in the shower makes installation less fiddly and time consuming.
2 YR
IPX4
Energy Efficiency Class - A
Water Pipe Entry
Electrical Cable Entry
NLSHOWER1
Order Code
Model No.
Output
(kW)
Power
Settings
Recommended
Cable Size
Recommended
Fuse Rating
Dimensions
(mm)
1051091527
NLSHOWER1
8.5
3
6-10mm²
40 Amps
335 x 225 x 89.5
Price - Each
1 off
£72.80
Upgrade from a 7.2kW shower to an 8.5kW. The kW rating affects the water flow of a shower with an 8.5kW rated shower having up to 18% more flow than a 7.2kW rated version.
Please note that 8.5kW rated showers require 40 amp fuses and must be fitted in accordance with BS 7671 (IEE Wiring Regulations) and Part P of the Building Regulations.
For 40 amp breakers please see page 155.
Professional Easy Fit Electric Shower
All the benefits of the Newlec Easy Fit shower PLUS:
• Additional 3 cable entry options and dual terminal blocks - allowing for cable entry from
top, bottom or rear of the shower from the left or right hand side.
• Chrome accessory kits with 6 mode shower head and adjustable fixing brackets meaning
existing fixing points can be used when replacing an existing shower.
• Push button Start/Stop for “set and forget” operation.
• Removable, easy clean inlet filter for easy maintenance.
2 YR
IPX4
Energy Efficiency Class - A
Water Pipe Entry
Electrical Cable Entry
NLSHOWER2
Order Code
Model No.
Output
(kW)
Power
Settings
Recommended
Cable Size
Recommended
Fuse Rating
Dimensions
(mm)
1051091526
NLSHOWER2
8.5
3
6-10mm²
40 Amps
335 x 225 x 89.5
Price - Each
1 off
£120.89
Upgrade from a 7.2kW shower to an 8.5kW. The kW rating affects the water flow of a shower with an 8.5kW rated shower having up to 18% more flow than a 7.2kW rated version.
Please note that 8.5kW rated showers require 40 amp fuses and must be fitted in accordance with BS 7671 (IEE Wiring Regulations) and Part P of the Building Regulations.
For 40 amp breakers please see page 155.
HVAC |
279
Instantaneous Water Heaters
Why use them?
• Provides instant unlimited hot water to one or
more sinks/basins - ideal for handwashing.
Benefits
Where to use them?
• Easy to install - simply requires cold water feed
and mains electricity.
• Energy efficient as no stored water needs to be
heated - Energy Efficient Class A-rated.
• Cloakrooms, kitchens and canteens where no
suitable hot water store is available.
Manual Handwash
• Energy efficient - located at point of use eliminating heat loss through long pipe
runs and only heats water on demand.
• Stainless steel 200mm swivel spout for durability.
• Preset safety cut-out - prevents overheating.
• Temperature stabiliser - ensures temperature of water is maintained, preventing
scalding.
• Pressure relief device - prevents high pressure build up should unit become
blocked or frozen.
2 YR
NLMHW3KW
Energy Efficiency Class - A
Order Code
Model No.
Power
Rating (kW)
Dimensions
H x W x D (mm)
1051043912
NLMHW3KW
3
235 x 151 x 98
Price - Each
1 off
£70.38
Automatic Handwash
All the benefits of manual handwash plus:• Easy to use “No Touch” on/off dial.
• Ideal for use in hospitals and GP surgeries - reduced risk of spreading germs
from touching contaminated dials.
• Tamper-proof adjuster for temperature and flow control - ensuring a
consistent temperature.
2 YR
NLAHW3KW
Energy Efficiency Class - A
Order Code
Model No.
Power
Rating (kW)
Dimensions
H x W x D (mm)
1051043913
NLAHW3KW
3
235 x 151 x 87
Price - Each
1 off
£147.06
Instantaneous Inline Handwash
• Energy efficient - only heats water on demand so no standing heat loss.
• Bare wire heating technology gives fast heat up times.
• Small compact shape, ideal for undersink mounting.
• Intended for use with spray head taps (NLNCT).
• Temperature stabilised and electronic temperature control maintain water
temperature to +/- 1°C.
Energy Efficiency Class - A
NLIWH4.4
280
NLNCT
|
Order Code
Model No.
1051058684
1051058685
NLIWH4.4
NLNCT
Power Rating Dimensions (mm)
(kW)
HxLxD
4.4
-
140 x 190 x 80
-
Price - Each
1 off
£250.01
£83.34
Vented Water Heaters
Why use them?
Benefits
• Provides hot water to a single sink or basin
- oversink and undersink models available.
Undersink units require vented taps.
Where to use them?
• Easy to install - simply requires cold water feed
and mains electricity.
• Kitchen sinks in workplaces, offices, workshops,
garages, industrial units and portable buildings.
Oversink Vented Water Heater
• Complete with tap and spout.
• No need for expansion vessel, pressure relief or pressure reducing valve easy to install.
• Safety resettable thermal cut out - simply switch off to reset.
• White corrosion proof case for durability.
• 1m pre-wired cable - saving time on installation.
1 YR
Energy Efficiency Class - A
NLV0S5L
Order Code Model No.
1051043904
NLVOS5L
Power
Rating (kW)
Capacity
(Litres)
2
5
Dimensions
Price - Each
H x W x D (mm)
1 off
400 x 270 x 180
£122.64
Undersink Vented Water Heater
All the benefits of an oversink vented water heater plus:• Comes complete with vented mixer tap - no need to purchase any additional
accessories.
• Unit is hidden under the sink with only the mixer tap visible on the work surface.
• Vented mixer tap is supplied with three flexible hoses for ease of installation.
1 YR
Energy Efficiency Class - A
NLVUS5L
Order Code Model No.
1051043905
NLVUS5L
Power
Rating (kW)
Capacity
(Litres)
2
5
Dimensions Price - Each
H x W x D (mm)
1 off
400 x 270 x 180
£190.77
Accessory
• For use with NLVUS5L undersink vented water heater (shown above).
Order Code
Model No.
1051043906
NLVMT
Description
Dimensions
H x W (mm)
Vented Mixer Tap
230 x 170
Price - Each
1 off
£70.67
HVAC |
281
Unvented Water Heaters/Flat Back Cisterns
Unvented Water Heaters
Why use them?
Benefits
• Provides hot water to single or multiple outlets.
Fed directly from the cold water mains supply and
operates at the same water pressure.
Where to use them?
• Provides high flow rates and balanced hot/cold
water supplies
• Can be used with standard taps.
• External temperature control and neon element on indicator.
• IPX4 rated - protected against water splashing from any direction.
• Safety manually resettable thermal cut out.
• Pressure relief valve supplied - additional safety feature that must be
fitted to prevent failure should pressure build up in the unit without
being released.
• Pre-wired 1.5M cable - saving time on installation.
NL10LUWH
1 YR
Order Code Model No.
1051043907
1051043908
1051043909
1051043910
NL10LUWH
NL15LUWH
NLEV
NLPRV
Description
Hot
Nearest Cold
Draw Off
2
2
-
Pressure
reducing
valve
(NLPRV)
Cold
T piece
Unvented
water
heater
To drain
(waste)
WRAS
Energy Efficiency Class - B
Power Rating Capacity
Dimensions
Weight Weight Full
(kW)
(Litres) H x W x D (mm) Empty (kg)
(kg)
2kW 10L Unvented Water Heater
2kW 15L Unvented Check Valve for Unvented
Expansion Vessel and Check Valve for Unvented
Pressure Reducing Valve for Unvented Heater
Pressure
Expansion
relief valve
vessel
(Included with (NLEV)
NL10LUWH &
NL15LUWH)
• Cloakrooms with multiple wash basins, kitchens
in offices, shops and commercial premises and
student accommodation.
Check
valve
(NLEV)
10
15
-
Service valve
Cold water mains
410 x 310 x 280
530 x 310 x 280
-
6.8
8.3
-
16.8
23.3
-
Heat Up
(mins)
23
35
-
Price - Each
1 off
£189.15
£207.09
£58.17
£43.48
Additional accessories may be needed to comply with the Water
Regulations.
• Pressure Reducing Valve (NLPRV) - Required if water pressure is
above 4.2 bar.
• 2 litre expansion vessel and check valve (NLEV) - Should be installed
if the length of pipework is too short to accommodate the expanded
hot water without re-entering the cold water supply. 2.8M of
pipework is required for a 10 litre heater and 4.2M pipework is
required for a 15 litre heater.
2.8 (10 l) or 4.2 (15 l) metres is
required for expansion
in pipework
Flat Back Cisterns
• 25 litre capacity.
• Thermostat adjustable between 18°C to 70°C with manually resettable
over temperature cut-out for additional safety.
• Long life alloy sheathed 3kW element.
• Simple left or right hand water inlet and overflow connections for
ease of installation.
• Sheet steel casing finished in white stoved enamel for added
durability.
NLFBC25A
2 YR
282
|
Order Code
Model No.
1051043914
NLFBC25A
Energy Efficiency Class - B
Power
Rating (kW)
Capacity
(Litres)
Dimensions
H x W x D (mm)
3
25
682 x 609 x 234
Price - Each
1 off
£634.07
Boiling Water Dispensers
Boiling Water Dispensers
Why use them?
Benefits
• Boiling water dispensers store boiling water ready
for instant use.
• Saves time as no waiting for kettles to boil.
• Saves energy as you only use the water needed.
• Saves space - uncluttered worktops.
Where to use them?
• Ideal usage: Any commercial environment where
there is a demand for boiling drinking water.
The Newlec range offers benefits including:
• Easy to install with easily accessible plumbing fittings.
• Removable steam condensation chamber for easy maintenance access.
• Electronic thermostat for greater control of water temperature up to boiling point.
• Dry start protection with a self-resetting thermal cut-out.
• Boil dry protection with a manually resettable cut-out.
2 YR
Order Code
Model No.
Capacity
(Litres)
Power Rating
(kW)
Dimensions
H x W x D (mm)
1051043915
1051043916
NLBWD2.5A
NLBWD5
2.5
5
2.5
2.5
445 x 290 x 190
510 x 335 x 200
Price - Each
1 off
£382.37
£650.34
NLBWD2.5A
Immersion Heaters
• All immersion heaters are fitted with RDT thermostats (Resettable Dual Thermostats)
which offer a combined thermostat and resettable safety cut-out.
• Adjustable from 10°C to 60°C - factory preset at 60°C.
• Suitable for use in both hard and soft water conditions.
2 YR
NLIIH11
Order Code
Model No.
1051043918
1051043920
NLIIH11
NLIIH27
Description
Power Rating
(kW)
3kW 11" Incalloy Immersion Heater
3kW 27" Incalloy Immersion Heater
3
3
Price - Each
1 off
£26.28
£30.92
Thermostats
• RDT thermostats (Resettable Dual Thermostats) offer a combined thermostat and
resettable safety cut-out.
• Provide a simple method of upgrading immersion heaters to meet latest BS standards
(BS EN 60335-2-73) without draining the hot water cylinder.
• Thermostats adjustable from 10°C to 60°C - factory preset at 60°C.
• Manual reset feature.
NLTHERM7
2 YR
Order Code
Model No.
Description
Power Rating
(kW)
1051043921
1051043922
NLTHERM7
NLTHERM18
7" Dual Thermostat Resettable Cutout
18" Dual Thermostat Resettable Cutout
3
3
Price - Each
1 off
£18.31
£21.26
HVAC |
283
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement