A)Department of Chest Medicine - College of Medicine & Sagore

A)Department of Chest Medicine - College of Medicine & Sagore
Government of West Bengal
Office of the Principal,
College of Medicine & Sagore Dutta Hospital
578, B T Road, Kamarhati, Kolkata – 700 058
Phone No : 033-2523-9057/58
NOTICE INVITING Re E‐ TENDER FOR PURCHASE AND INSTALLATIOIN OF EQUIPMENT FOR
VARIOUS DEPARTMENTS OF COLLEGE OF MEDICINE & SAGORE DUTTA HOSPITAL BY THE
PRINCIPAL COLLEGE OF MEDICINE & SAGORE DUTTA HOSPITAL.
(Through Pre‐qualification)
(Submission of Bid through NIC e‐ tender portal)
Memo No. CMSDH/ 1037/15
Date‐ 11.06.2015
The Principal, College of Medicine & Sagore Dutta Hospital is going for re e- tender on behalf of the Health
& Family Welfare Department, Government of West Bengal for purchase & installation of equipment for various
departments as per annexed list from the bona fide manufacturer /authorized distributor.
Necessary earnest money to be submitted for Participation in the Tender through Demand Draft/Pay
order is appended in the table below:
Name of the items
As Enlisted
Earnest money
As per Column “D” of List of Instruments
List of Instruments:
A)Department of Chest Medicine:
Sr.
No.
Item No.
(A)
1
CHE-EQ-01
2
CHE-EQ-02
Name of the Instrument
(B)
Video Bronchoscope (Adult) with leakage tester
and Medical Grade Monitor
Digital Video Processor with 100-300 Watt Xenon
Light Source and Image capturing Software for
video recording and reporting for Video
Bronchoscope(Adult), TBNA needle,endoscopy
trolley, computer with printer and 2 KV UPS
1
Quantity
(C)
1
1
Earnest money
(D)
Rs.-20,000 per
tenderer
(for any one or
all)
B)Department of Ophthalmology:
Sr.
No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
3
OPH-EQ-01
OPERATING MICROSCOPE FOR OPHTHALMOLOGY
with PHOTOGRB SYSTEM
6
4
OPH-EQ-02
VISUAL FIELD ANALYZERS(Automated Perimeter)
with/without SWAP
6
5
OPH-EQ-04
Spectral Domain OPTICAL COHERENCE
TOMOGRAPHY
6
6
OPH-EQ-05
RETINAL LASER PHOTOCOAGULATOR
Earnest money
(D)
Rs.-20,000 per
tenderer
(for any one or
all)
6
C)Department of Forensic Medicine & Toxicology
Sr.
No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
7
FMT-EQ-01
Mortuary Cabinet (Cooling chamber for dead
body storage)
8
8
FMT-EQ-02
Ozone Generator
20
9
FMT-EQ-03
Deadbody Weighing Machine / Cadaver Weighing
Scale
2
10
FMT-EQ-04
Viscerae / Organ Weighing Machine
2
11
FMT-EQ-05
Autopsy Saw (Electrical)
2
12
FMT-EQ-06
Autopsy Instrument Box
10
13
FMT-EQ-07
Autopsy Table
3
Earnest money
(D)
Rs.-10,000 per
tenderer
(for any one or
all)
D)Department of Pathology:
Sr.
No.
14
Item No.
(A)
PATH_EQ -01
Name of the Instrument
(B)
Automated tissue processor
Quantity
(C)
1
15
PATH_EQ -02
Grossing Station
1
16
PATH_EQ -03
1
17
PATH_EQ -04
Dual Head Trinocular Microscope with
Photomicrographic Attachment
Specimen Jar (Rectangular) with Cover for
Museum
2
Earnest money
(D)
100
Rs.-10,000 per
tenderer
(for any one or
all)
E)Department of ENT:
Sr.
No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
18
ENT_EQ -01
Adult nasal endoscopes
1
19
ENT_EQ -02
Paediatric nasal endoscopes
1
Earnest money
(D)
Rs.-10,000 per
tenderer
(for any one or
all)
F) Department of Microbiology:
Sr.
No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
20
MCB_EQ -01
Automated Microbial Growth Detection System
1
21
MCB_EQ -02
Automated Mycobacterium Growth Detection
System
1
22
MCB_EQ -03
TRINOCULAR MICROSCOPE WITH INFINITY
CORRECTED OPTICAL SYSTEM WITH
FLUORESCENCE ATTACHMENTS
1
23
MCB_EQ -04
Media Preparation System
1
24
MCB_EQ -05
Automatic Pourer and Stacker
1
25
MCB_EQ -06
Automated Tube Media Dispenser
1
Earnest money
(D)
Rs.-10,000 per
tenderer
(for any one or
all)
G)Department of Radiology:
Sr.
No.
26
Item No.
(A)
RADIO-EQ-01
Name of the Instrument
(B)
800mA X-ray R/F System with IITV
3
Quantity
(C)
1
Earnest money
(D)
Rs.-10,000 per
tenderer
(for any one or
all)
H)Department of Pharmacology:
Sr.
No.
Item No.
(A)
27
PHAR_EQ_01
28
Name of the Instrument
(B)
Quantity
(C)
20
PHAR_EQ_02
Assembly for isolated tissue experiment with
(Dale’s organ bath)
Laboratory thermometer
29
PHAR_EQ_03
Kymograph (Students) Electric independent unit
20
30
31
PHAR_EQ_4
PHAR_EQ_5
Analytical balance
LCD projector
1
5
32
PHAR_EQ_6
Glass pill tile
30
33
PHAR_EQ_7
Porcelain pill tile
30
34
PHAR_EQ_8
Laser Printer, scanner. Copier for office & PvP
5
35
PHAR_EQ_9
Reagent bottle
400
36
PHAR_EQ_10
Measuring cyllinder
20
37
PHAR_EQ_11
Measuring cyllinder
20
38
PHAR_EQ_12
Steel spatula
30
39
PHAR_EQ_13
Steel spatula
40
40
PHAR_EQ_14
Glass funnel
20
41
PHAR_EQ_15
Polypropylene Mice Cage
10
42
PHAR_EQ_16
Polypropylene Rat Cage
15
43
PHAR_EQ_17
Cage for guineapig(S.S.)
10
44
PHAR_EQ_18
Cage for rabbit (S.S.)
5
45
PHAR_EQ_19
O.T. table for small animal (S.S.)
2
46
PHAR_EQ_20
Rat restrainer
1
47
PHAR_EQ_21
Mouse restrainer
1
48
PHAR_EQ_22
Animal weighing mechine
2
49
PHAR_EQ_23
Room Heater
5
4
Earnest money
(D)
20
Rs.-5,000 per
tenderer
(for any one or
all)
I)Department of Bio-chemistry:
Sr. No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
BIO-EQ-01 Horizontal Electrophoresis Apparatus with Power
Pack
2
51
BIO-EQ-02 Centrifuge (8 tube)
2
52
BIO-EQ-03
Double pan Balance
4
53
BIO-EQ-04
Single pan electronic balance
2
54
BIO-EQ-05 Fully Automated Clinical Chemistry Analyzer
50
Earnest money
(D)
Rs.-5,000 per
tenderer
(for any one or
all)
Rs.-10,000 per
tenderer.
1
J)Department of Gynaecology
Sr.
No.
55
Item No.
(A)
Gynae-EQ-01
Name of the Instrument
(B)
VACUUM DELIVEY SYSTEM( Digital-LEDMODEL)
Quantity
(C)
2
Earnest money
(D)
Rs.-5,000 per
tenderer.(for any
one or all)
K)Department of Anaesthesiology:
Sr.
No.
Item No.
(A)
Name of the Instrument
(B)
Quantity
(C)
56
ANA-EQ-01
Anaesthesia
Machine
4
57
ANA-EQ-02
CPR Training Manikin (Adult)
1
58
ANA-EQ-03
Multi-functional Airway Management Model
1
59
ANA-EQ-04
Nerve Locator
2
5
Earnest money
(D)
Rs.-10,000 per
tenderer
(for any one or
all)
1.General Instructions:
In the event of e‐filing, intending bidder may download the tender documents free of cost from the
website : http://wbtenders.gov.in directly with the help of Digital Signature Certificate or from the
Health & Family Welfare Department’s website www.wbhealth.gov.in& necessary earnest money may
be remitted to the office of the Principal, College of Medicine & Sagore Dutta Hospital through demand
draft / pay order issued from any nationalized bank/scheduled bank in India drawn in favour of Principal,
College of Medicine & Sagore Dutta Hospital Kamarhati and also to be documented through e‐filling.
2. Submission of bids:
Both Technical bid and Financial Bid are to be submitted concurrently duly digitally signed in the website
http://wbtenders.gov.in. All papers must be submitted in English language.
Training : All the bidders are hereby requested to take training before submission of bids.
3. Time Schedules for the e‐tender
THE TIME SCHEDULE FOR OBTAINING THE BID DOCUMENTS, PRE BID MEETINGS, REGISTRATION
WITH THE TENDERING AUTHORITIES, THE SUBMISSION OF BIDS AND OTHER DOCUMENTS ETC.
WILL BE AS PER THE LIST PROVIDED IN CLAUSE NO 24 AS GIVEN BELOW.
4. ELIGIBILITY FOR QUOTING :
Only Manufacturers, Direct Importers, authorized distributors are only eligible for quoting. The
price is to be quoted in Indian Rupees including cost of insurance, custom duty, packing,
forwarding, freight charges, clearing charges and transportation. Agency commission, if any
payable in Indian Rupees should also be mentioned.
5. SUBMISSION OF THE TENDERS :
`The tender is to be submitted in a two Bid System.
[A] Technical Bid:
`(a). Statutory Cover containing the following documents:
1. COVER “A”:
“BID A”: PART I
One folder for earnest money deposit with copy of the Demand draft/Pay order should be
uploaded. Local SSI(s) should upload certificate of registration/EM II for claiming EMD
exemption.
(SINGLE FILE MULTIPLE PAGE SCANNED)
Essential Requirements of the Tendering Firm for participation” shall contain all papers related
to the essential requirements of the Tenderer for participation in the tender viz.
A
Copy of Demand Draft/Pay order in favour of Principal College of Medicine & Sagore
Dutta Hospital & Hospital issued from any nationalized bank/scheduled bank in India.
B
CHECK LIST in the prescribed format
C
Application in the prescribed format given in Annexure I
D
Authorization letter of signatory from Company in Annexure II
E
Technical specifications of Instruments. (in PDF FPRMAT) In given format only
6
“BID A”: PART II
Essential Requirements of the Tendering Firm for participation
(SINGLE FILE MULTIPLE PAGE SCANNED)
1. TECHNICAL SPECIFICATIONS OF INSTRUMENTS. (in PDF FPRMAT) In given format only.
NON‐STATUTORY/ MYDOCUMENTS containing the following documents:
Sr.No. Category
Sub Category
Sub Category Description
A
A1. Certificates
PAN Card of the authorized signatory
Certificates
Professional Tax Registration certificate
VAT/ CST Registration certificate
B
C
COMPANY DE
TAILS
B1. COMPANY
CREDENTIAL
C1: CREDENTIAL 1
Certificate of country of origin
Registration with Registrar of Companies
Manufacturing License
Import License with validity (for importers)
C2 : CREDENTIAL 2
Manufacturer’s guarantee
Inspection certificate
LIST OF PURCHASER
D
FINANCIAL
INFO
PAYMENT
CERTIFICATE 1
PAYMENT
CERTIFICATE 2
Income Tax Returns submitted for the Financial year 2011‐12
Income Tax Returns submitted for the Financial year 2012‐13
Income Tax Returns submitted for the Financial year 2013‐14
VAT/CST Returns (of the last quarter) for the year 2011‐12
VAT/CST Returns (of the last quarter) for the year 2012‐13
VAT/CST Returns (of the last quarter) for the year 2013‐14
1. P/L & Bl. sheet
1. P/L & Balance sheet 2011‐2012
2. P/L & Balance sheet 2012‐2013
3. P/L & Balance sheet 2013‐2014
7
2. COVER “B” :
[B] FINANCIAL BID “B” :
(i) BOQ in INR (in excel sheet)
The folder as “Financial Bid” shall contain base price in Indian Rupee and the portion of the
allied works and services which are to be undertaken in India (like installation, commissioning
of equipments or PC etc.) are to be quoted in Indian currency including cost of insurance,
packing, forwarding, freight charges, clearing charges, custom duty and installation
transportation. Agency commission, if any payable in Indian Rupee should also be mentioned.
The tenderers are required to submit the hard copies of Bid A as per schedule more clearly
described in the time line vide clause 24 along with Earnest Money Deposit (EMD) in separate
packets. Submission of hard copy of Bid A to the office of the Principal, College of Medicine & Sagore Dutta
Hospital is for reference only while examining the technical bid on line and will not be
treated as substitute for on line submission. Submission of hard copy of Bid B is totally
prohibited and only be submitted through on line through NIC portal.
6. Evaluation of the tenders
During the tender evaluation process, the “Bid A” will be opened first. Those Tenderer who
have qualified the essential & other requirements will be identified and only their “Bid B” i.e.
Financial bid will be opened. The “Bid B” of those Tenderer failing to meet the technical & other
requirements of participating in the tender will not be opened and will be rejected. The
Tenderer offering the item found suitable and being as per the tender specifications will only be
selected.
The Tenderer who have been so identified to have been technically suitable in the context of
above will be deemed to have passed the test of essential and other requirement of the quoted
item or items.
The “Bid B” (Financial Bids) of only these tenderers passing the essential and other requirement
test will be opened then subject to verification of hard copies of the audited balance sheet and
Profit & Loss Accounts of the tenderer for the last three years i.e for the year 2011‐12, 2012‐13
& 2013‐14.
If found suitable in the context of above pre qualification etc, the Tenderer quoting the lowest
rate will be considered as successful.
7. Cost of Earnest Money :
Each tender has to submit, unless exempted under the existing orders of the West Bengal Govt.
must deposit Earnest Money As per Column “D” of List of Instruments
in the form of Demand Draft/Pay order from any Nationalized
Bank/scheduled bank in India in favour of Principal, College of Medicine & Sagore Dutta Hospital, payable at
Kolkata.
The earnest money is to be deposited in the prescribed time before opening of Bid A. The onus
of proving that a Tenderer is exempted from Earnest Money will lie on the Tenderer and must
be proved by submission of valid documents.
The earnest money of the Tenderer will liable to be forfeited if the Tenderer withdraws his
tender as a whole or for any particular item or items at any stage after the opening of the
tender, or fails / refuses to enter into written agreement for any of all of the items of his
accepted tender within the time specified when requested to do so/fails to furnish
Performance Bank Guarantee within the stipulated time.
The Earnest Money will be refunded after finalization of the tender or within 3 (three) months
from the date of opening of tender whichever is later against the specific prayer of Tenderer.
8
8. RATE:
The price is to be quoted in Indian Rupees including cost of insurance, custom duty,
packing, forwarding, freight charges, clearing charges, installation& transportation.
The basic rate should be furnished inclusive of Customs Duty, Transportation Cost, Insurance,
Freight, Testing charges, Incidental Charges etc. but excluding of VAT/CST, Excise Duty, Entry
Tax & Cess etc. which shall be quoted separately in the template for Bill of Quantities (BOQ).
Percentage of Excise Duty, CESS etc, Percentage of VAT to be mentioned in the appropriate
Column of the template for Bill of Quantities.
9. ORDER & SUPPLY:
Orders for the supply of the approved products will be placed with the successful tenderers
after the execution of the agreements, and such supply shall have to be made in such
installments as may be fixed or spread over a period to be specified in the supply orders to be
made in pursuance of the agreements. The successful tenderer will have to supply within the
specified time schedule that had been assured at the time of selection as supplier.
10. WITHDRAWAL /CANCELLATION & PURCHASE POLICY OF TENDERING AUTHORITY:
The tendering authority reserves the right to withdraw any item from the tender at any stage.
The selection of such item, if already made in favour of any Tenderer, shall be treated as
cancelled.
The tendering authority reserves the right to reject or accept any tender or part thereof at any
stage or to split any tender without assigning any reason. Withdrawal of tender or any revision
after submission of tender by the Tenderer will not be allowed.
The tendering authority reserves the right to accept or reject any tender, in part or in full,
without assigning any reason.
Purchase will, however be made following the existing purchase policy of the Govt of West
Bengal and its amendment(s) made from time to time. The purchase policy of the State
Government as provided in the West Bengal Financial Rules, the policy of price preference in
particular incorporated under Notification No. 5400‐F dated 25.06.2012 should be observed in
considering the tenders.
11. Important Instruction with regard to submission of tender.
The rate should be quoted in Indian Rupees (both in figure and words) for a particular brand or
model / model no. of the offered item only as mentioned in the appropriate column of the
'Tender Form'. (Alternative offer will not be accepted). The tender shall be cancelled for the
quotation of item without its brand name, model, model no. etc. The detail information
regarding the manufacturer and the item quoted in the 'Tender Form' shall be furnished.
12. Spare Parts
The Bidder will undertake that supplies of necessary maintenance equipment and spare parts
will be made available for all items/equipments and the complete system for a least five years
on a continuing basis.
However, this does not relieve the supplier of any warranty obligations under the contract.
13. GUARANTEE /WARRANTY PERIOD:
THE TENDERERS MUST QUOTE FOR 1 YEAR COMPREHENSIVE ON SITE WARRANTY OF ENTIRE
SYSTEM (INCLUDING ALL SPARES & LABOUR) FROM THE DATE OF COMPLETION OF THE
SATISFACTORY INSTALLATION. For Extended warranty of 3 years rate should be quoted
separately.
13.2 All faults appearing and their rectification shall be periodically advised to the laboratory,
the period being not more than a month.
9
13.3 Any lacuna or lacunae noticed in the functioning of the installation as a result of any
design feature shall be rectified by the supplier free of cost.
14. After Sales Services and Maintenance Contract
After sales services will be provided by the supplier during and after guarantee period of the
equipment. Details along with the yearly comprehensive maintenance charges for 5 year after warranty shall be
quoted separately.
15.Delivery, Installation and Commissioning
15.1 Delivery of the goods at the purchaser's premises shall be completed by the Supplier in
accordance with the terms specified by the purchaser.
15.2 The installation, testing and commissioning of the proposed system shall be completed
in accordance with the order.
15.3 In case of distributor, the firm should be direct distributor from the principal's. The sub‐
distributor authority by distributor will not be accepted at all.
16. SPECIAL TERMS AND CONDITIONS FOR TENDER SUBMISSION
The tenderer should have been in this business for a period of at least two years in the country
in relation to the type of equipment for which the quotations / tenders are being submitted.
A proof of ownership/partnership etc. shall be submitted along with verification of address,
telephones and fax numbers.
The tenderer should submit statement of financial standing from their bankers. The name of
the bank along with full address is to be furnished.
The supplier should submit a statement of overall turnover for the previous three years. If
applicable a copy of the applicants annual report and accounts for each of the last three years
should also be submitted.
The tenderer is also required to submit performance report from other similar organization
where the firm is registered for supply and erection of similar projects of hospital
equipment/system. He will also submit list of organizations where the System has been
installed by the firm in the last two years along with a good standing certificate from competent authority.
The tenderer has to give a certificate that the firm has not been blacklisted in the past by a
Institution Government/Private or convicted in any criminal case.
If the tenderer gives a false statement on any of the above information the firm/supplier will
not be considered and their quotation/tender shall be rejected and the security deposited shall
be forfeited. The manufacturer should submit all the quotations directly or through their authorized agent
where applicable provided the manufacturer accepts responsibility for any lapse on the part of
the agent and authorization certificate must be enclosed.
Quality assurance certification like ISO 9000 series should be enclosed wherever applicable.
17. PENALTY CLAUSES‐
PENALTY FOR FORMATION OF CARTEL OR FURNISHING OF FRADULENT/ MISLEADING
DOCUMENTS: If during the tender process or at any state during the validity of the tender
period, it is found that a Tenderer(s) has formed a cartel in what so ever form or name to fix up
the rates or suppliers to the detriment of the fairness of the tender process, penal measures
shall be initiated. Similar penal measures shall also be initiated against those tenderers who
have submitted false/ misleading/ fraudulent documents or made incorrect declarations. The
penal measure will be Forfeiture of Earnest Money, Forfeiture of Performance Bank Guarantee
if enlisted as a supplier.
18. APPEAL:
Appeal against the decision of the Principal College of Medicine & Sagore Dutta Hospital to impose
such a penalty will lie with Tender Selection Committee. Review against the decision of the
T.S.C. will lie with Health & F.W. Deptt of the GovtThe Special Secretary/Secretary/Principal
Secretary will be the appellate authority within the Department of Health & Family Welfare,
10
Government of West Bengal. Before imposing any penalty as per clauses 21, 22 and 23 the
concerned supplier may appeal to the authority citing the proper reasons for non‐ imposing the
penalty as stated.
19.AGREEMENT:
On a tender being accepted, intimation of acceptance will be forwarded to the Tenderer by
Principal College of Medicine & Sagore Dutta Hospital. After communication of the same, the
Tenderer and the selected distributor (in the event of distributor to receive order and payment
in his name) will have to execute agreement in the prescribed form with the Principal
College of Medicine & Sagore Dutta Hospital. This present document and the tender forms filled in
by the Tenderer or copies thereof in so far as they are not inconsistent with these terms &
Conditions will be incorporated as part of the agreement. Such agreement will be binding on
the Tenderer and distributor.
20. VALIDITY PERIOD OF AGREEMENT:
The contract period will be for a period 180 days from the date of finalization of tender.
21. PERFORMANCE BANK GUARANTEE’
The performance bank guarantee will be mandatory for all suppliers and will not be waived in
any case.
The successful tenderers shall be required to furnish the ‘Performance Bank Guarantee’@ 10%
of base rate per item for which the Tenderer has been selected as supplier.
22.INSPECTION:
Before submitting the tender, the intending tenderers should thoroughly acquainted
themselves with the proposed supply and installation by local inspection of site and make into
consideration the site condition and other criterion for effecting smooth supply. No claim
whatsoever will be entertained afterwards.
23. PAYMENT TERMS:
Payment will be made through e payment system through ECS/RECS/RTGS after execution of
due supply as ordered subject to :
Submission of Performance Bank Guarantee in terms of Clause 21 and subject to penalty clause
in terms of Clauses 17.
Supply of the materials as per specification as provided in the tender documents and the
catalogue.
Supply of the materials within the supplied period as specified in the work orders.
On being selected, the successful vendors will have to submit one application to the Principal
College of Medicine & Sagore Dutta Hospital and concerned procuring authorities. Stating the
name of the payee/ recipient, Bank account no with MICR code, IFSC of the payee/recipient for
making e payment.
No manual payment is allowed to be made as far as practicable.
In case of letter of credit (LC), purchaser’ bank issues Guarantee of Payment against LC opened
in that bank to the Suppliers bank for payment as mutually agreed by both the purchaser and
the supplier.
100% payment will be released after successful installation of the instruments and production of the followings.
I) Supplier’s invoice in original
ii) Packing List
iii) Certificate of Country of origin
iv) Manufacturer’s guarantee and inspection certificate
v) Insurance Certificate
vi) Name of vessel/carrier
vii) Bill of Landing/Airway bill
viii) port of Loading
x) Date of shipmen
11
24.Dates &Information :
Sn
1.
Items
Date of uploading of N.I.T. Documents (online) from this end.
Publishing date(s)
13.06.2015
2.
Documents download/sell start date (Online)
13.06.2015
3.
Date of hoisting of documents at Departmental Website
(www.wbhealth.gov.in)
13.06.2015
5.
6.
7.
20.06.2015 at 04:00 PM
Bid Submission starting (On line):
8.
9.
Bid Submission closing (On line):
Last Date of submission of original copies along with Earnest Money De
posit (Off line) :
Bid opening (Bid A ) :
Date of uploading list for Technically Qualified Bidder (online)(Bid A) :
06.07.2015 by 2 PM
06.07.2015 by 3 PM
06.07.2015 3pm onwards
08.07.2015 onwards
10.
11.
Date & Place for opening of Financial Proposal (Bid B) (Online):
Date of uploading of list of bidders along with the approved rate:
08.07.2015 onwards
08.07.2015 onwards
THE PRINCIPAL College of Medicine & Sagore Dutta Hospital RESERVES THE RIGHT TO
CHANGE THE ABOVE SCHEDULE IN CASE OF ANY EXIGENCIES AFTER PUTTING UP A NOTICE IN
THE DEPARTMENTAL WEBSITE, COLLEGE WEBSITE AND OFFICE NOTICE BOARD.
25.Validity of Tender :
The tender will remain valid upto30th June 2016
No objections in this respect will be entertained raised by any Bidder who will present during
opening of bid, or from any Bidder who will absent at the time of opening of Financial Bid. No
informal tenderer will be entertained in the Bid further.
During the scrutiny, if it come to the notice to tender inviting authority that the credential or
any other paper found incorrect/ manufactured/ fabricated, that bidder would not allowed to
participate in the tender and that application will be out rightly rejected without any prejudice.
Prospective bidders must take training from authorised agencies before submission of their
bids.
The Tender Selection Committee reserves the right to cancel the N.I.T. due to unavoidable
circumstances and no claim in this respect will be entertained.
Memo No. CMSDH/ 1037/15
Sd/
Principal
College of Medicine & Sagore Dutta Hospital
578, B T Road, Kamarhati
Date‐ 11.06.2015
Copy Forwarded for information to:1. The Principal Secretary to the Government of West Bengal, Department of
Health & Family Welfare, (Medical Administration Branch), SwasthyaBhavan, Kolkata- 700 091.
2. Director of Medical Education & Ex- Officio Secretary, SwasthyaBhavan, Kolkata-91.
3. Director of Health Services & Ex- Officio Secretary, SwasthyaBhavan, Kolkata-91.
Sd/
Principal
College of Medicine & Sagore Dutta Hospital
578, B T Road, Kamarhati
12
FORMAT FOR CHECK LIST
Sl. No
1
Items
Application submitted in Annexure I
Pl mark √
Yes
No
2
Annexure II ( Authorization letter of signatory from the
Company)
Yes
No
3
Annexure III ( Copy of agreement between the manufacturer
and the Distributor)
Yes
No
4
Copy of PAN Card of the authorised signatory :
Yes
No
5
Copy of Demand Draft/Pay order As per Column “D” of List of
Instruments in favour of THE PRINCIPAL College of Medicine & Sagore
Dutta Hospital as Earnest Money
Yes
No
6
Last 3 financial years’ returns of Income Tax i.e. for 2011‐12
2012‐13& 2013‐14
Yes
No
7
Last quarters of last 3 financial years’ returns of VAT for
2011‐12 2012‐13& 2013‐14
Yes
No
8
Last quarters of last 3 financial years’ returns of CST for
2011‐12 2012‐13& 2013‐14
Yes
No
9
Affidavit of non conviction affirmed before a Notary public/
First Class Judicial Magistrate/Executive Magistrate (affidavit
sworn after 15.06.2015)
Yes
No
10
Lead time compliance certificate from the tenderer
Yes
No
13
Page no
Annexure I
APPLICATION FORMAT
( To be furnished in the Company’s official letter pad with full address and contact no etc)
To The Principal,
Sub: NIT for Various Departments of College of Medicine & Sagore Dutta Hospital, West Bengal.
Ref:‐
Sir,
Having examined the pre‐qualification & other documents published in the N.I.T, I /we hereby
submit all the necessary information and relevant documents for evaluation:
1. That the application is made by me / us on behalf of ………………………………………
In the capacity of……………………………………………..…duly authorized to submit the offer. The
authorization letter from the Company is attached in Annexure II.
2. We accept the terms and conditions as laid down in the NIT mentioned above and
declare that we shall abide by it for throughout the tender period.
3. We are offering rate for the following item /items and assured supply to the Health &
Family Welfare Department, Government of West Bengal as per Table‐1(Instuments Specification)
4. a. We propose that the order and bill should be raised in our name.
For liaisoning, we have appointed M/S ……………………………………………….. having its office at
………………………………………………………………………………. (address, contact no and e mail address) as
C&F agent /Liaisoner /Contact person/………. Others (strike out whichever is not applicable) as
per clause ……… of the NIT
OR
b. We propose that order and bill should be raised in favour of our authorized distributor.
For that purpose, we have appointed M/S …………………………………………… having its office at
………………………………….. (address with contact no and e mail address) as authorized Distributor
who will receive order and payment in his name on our behalf.
c. The agreement between ourselves and the distributor/C&F/Liaisoner& other documents
as prescribed is attached in annexure III
5. In the event of being selected, supply will be made within the stipulated period
excepting the condition which is beyond our control.
6. We understand that:
(a) Tender Selection Committee/ H&FW Dept can amend the scope & value of the contract bid
under this project.
(b) Tender Selection Committee/ H&FW Dept reserves the right to reject any application
without assigning any reason ;
Date :‐
Signature of applicant including title
and capacity in which application is made.
Contact no :
Tele :
Mobile :
E Mail address :
14
Annexure II
Authorization letter from Company for authorized signatory
15
Annexure III
Copy of agreement signed between the tenderer and the Distributor etc.
16
TABLE I
LIST OF INSTRUMENTS WITH TENTATIVE REQUIREMENT
(SPECIFICATIONS)
Name of the Instruments :
1. Video Bronchoscope (Adult) with leakage tester and Medical Grade Monitor:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
1.Specifications for Video Bronchoscope with
Medical grade monitor:

It should provide full-screen clear
images on the monitor.
 Field of view should be 1200 or more
 It should have tip deflections as
follows:
a) Up- 1800
b) Down- 1300
 It should have an outer insertion tube
diameter of 6.3 mm or less.
 Its instrument channel diameter should
be 2.8 mm or more
 Its working length should be 600 mm or
less and total length should be not
more than 860 mm.
 It should have a locking button to fix
the scope in a particular position during
performing procedures and capturing
images.
 It should have an image capturing
button on the outer body of the scope.
 It should be compatible for use with
High-frequency Treat devices
 It should be provided with all standard
accessories including cleaning
accessories, Leakage tester, Biopsy
forceps, bronchial cytology brush.
It should be provided with a 19 inch Medical
grade monitor high definition (HD) compatible
with 100-300 Watt Xenon processor.
17
Bidders
deviation if
any
2. Digital Video Processor with 100-300 Watt Xenon Light Source and Image capturing Software for video
recording and reporting for Video Bronchoscope(Adult), TBNA needle,endoscopy trolley, computer with printer
and 2 KV UPS:
SI. no. Technical Specifications
Technical Specification quoted
Bidders
by bidder
deviation if
any
1
Digital Videoprocessor with Xenon Light Source
and Image capturing software for video recording
and reporting for Video bronchoscope (Adult),
Computer with printer and 2 KV UPS, Endoscopy
trolley,TBNA needles:
















Should be fully digital system: combination
of digital signal processing, high resolution
CCD chips and the latest video processors.
Should have superb illumination with a high
performance Xenon light source and digital
brightness control.
Should have easy and intuitive data
management for rapid storage and
management of patient and user data.
Should have effective digital video
processing for the most common
applications
Light source: 100Watt Xenon-300 Watt
Xenon light source
Colour Temperature: ≤ 6500 K
Brightness control: Automatic/Manual (11
steps).
System: Average/peak
Colour correction: red/blue ± 5 steps
Contour enhancement : Minimum 4 steps
Data management: Minimum 30 patients/
50 users
Outputs: 1 x RGB, 2 x Y/C (S-VHS), 1 x
Composite (FBAS)
It should be provided with Image capturing
software for capturing images, video
recording and reporting .
It should be provided with a computer
compatible with the processor with 2 KV
UPS and printer.
It should be provided with an Endoscopy
trolley.
It should be provided with reusable TBNA
needles.
18
3.OPERATING MICROSCOPE FOR OPHTHALMOLOGY with CCTV AND CO-OBSERVER
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
1.5 step Apochromatic magnification changer
integrated in microscope body
2. Magnification factors 0.4, 0.6,1.0,1.6, 2.5
3.Tube -450 Inclined binocular tube f=170mm with
P.D.adjustment via knob from 55mm- 75mm or
more
4.12.5x wide field –pieces with +/- power
adjustment up to 6.0 D
5. Focussing -Motorised (foot control fine
focusing range 40mm)
6. Main Objectives-- f=200mm, apochromatic
7.Eyepiece –Push-in wide field eyepiece 10x
8.Filters – Day light filters& Eye protection filter
9. Illumination system—Fiber optic illumination
with 12V 100W Halogen reflector bulb /
5W(4500K) LED
10. Footswitch –Compact footswitch
11. Floor stand with lockable caster with heavy
base
12. Upgradable for XY coupling
13. Spring balance suspension arm
14. UV filter to prevent Blue light
Accessories:
1.XY Translator
2.Assistant Scope
3.Beam splitter
4.SONY 1CCD1/2” C Mount Video Camera SSC –
19
Bidders
deviation if
any
G818
5.DVR System for Recording
6.Sony/Samsung 19” TV Monitor
4. VISUAL FIELD ANALYZERS
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
1. High quality goldman standard automated
perimeter with maximum intensity 10,000Asb
2. Visual Field Testing
illumination 31.5Asb
distance-30cm,Bowl
3. Stimulation duration 200ms
4. Stimulus : White on White, Red or Blue on
White
5. Maximum temporal range 89 degree.
6. Threshold Testing: Central : 30-2,24-2,102,Macula
7. Threshold Testing: Peripheral : 60-4,Nasal
Step
8. Threshold test strategies: Full threshold, Fast
Pac, SITA (Standard & Fast)
9. Operator Interface: Keyboard
10. Fixation Monitoring: Video eye monitoring,
Trial Lens Holder, Gaze tracking System
11. Software features:
a)Statpac-2: Single Field Analyzer,
b)Glaucoma Hemifield Testing(GHT),
c) Visual Field Index,
d)Glaucoma Progression Analysis
e)Serial Field overview
f)Networking
12. Screening test: C-40,C-64,C-76,C-80, CArmaly
13. Screening test modes : Age related, Threshold
related modes
20
Bidders
deviation
if any
14. General Testing: Stimulus Size I-V as per
Goldman standards , Foveal Threshold testing
15. Data Storage & Retrieval: Internal hard disk
160 GB, USB
16. Motorized table with Laser Jet Printer
17. Should have connectivity solution with other
equipments like OCT, Fundus Camera
18. After sales service should be available from
directly from Manufacturer
5.SD OPTICAL COHERENCE TOMOGRAPHY:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Specifications:
1. Scan Mode:
Fundus)
Color, red free (True color
2.Picture angle : 45/30
degree/equivalent(digital zoom)
3.Operating distance: 34.8mm(Fundus
photography)& 62.6mm(in Ant seg
photography)
4.Photographable diam of pupil: 45degree4.0mm or more& small pupil diam 3.3mmor
more
5.Fundus image resolution(on Fundus):
Center:60lines/mm or more,
middle(r/2):40lines/mm or more, middle25lines/mm or more
6. Scan range on Fundus: Horizontal 312mm & vertical-3.9 mm
7.Scan range on Cornea: horizontal: 3-6mm
& vertical-3-6mm
21
Bidders
deviation
if any
8. Scan speed: 50000 a scans/ second
9. Lateral Resolution: 20µm
10.In depth resolution: 6µm
11.Diam of Pupil: 2.5mm or more
12. User friendly, auto align, Auto Focus &
Capture
13.OCT scan providing measurement &
tomography of Optic Nerve & macula in one
scan
14.Anterior Segment Tomography (pref. in
built) should be available
15. Internal Fixation target: Dot matrix type
organic EL
16.External PC with HD 1TB & 4GB RAM
22
6. RETINAL LASER PHOTOCOAGULATOR:
SI. no. Technical Specifications
Technical Specification quoted
by bidder
1.Laser system : DPSS True CW/ Frequency doubled
solid state laser
2.Safety classifications : Class 4
3.Wavelength: Green (532nm)
4.Power Output : 50mw-2.0w
5.Max power at Cornea: 1.5-2.0w
6.Pulse duration(single pulse): 10 -2500 ms & or more
option
7.Pulse interval :100 to 6000 ms & continuous
8.Cooling: Auto fan and TEC ‘s for laser & crystal
9.Treatment spot size: 50 to 500-1000µm contiguously
variable or stepped/ 50 to 100µm contiguously
variable(integrated version)
10.Aiming Beam : Laser diode 620 -653 nm, 1mw at
the Cornea
11.Safety Classifications: Class 2
12. Laser console weight: 12-14 kg
13: Slit lamp Delivery system over a motorized table
with Tonometer
14.Laser safety goggles, Contact lenses (Mainster PRP
165 deg. & Panfundoscopic), laser warning light
15. Co observer Tube
Optional accessories:
1.IO delivery system
23
Bidders
deviation if
any
7. Mortuary Cabinet (Cooling chamber for dead body storage):
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if
any
To be purchased: 6-body cooling chamber.
Size of Tray:2100 – 2200 mm (length) × 500 – 600 mm
(breadth) × 300 – 450 mm (height)
Dimension:2500 – 2700 mm × 1600 – 1700 mm × 1900 –
2000 mm
Temperature range:
0 - 4:C
Other features: Must have rust-proof coating paint
Must be equipped with temperature indicator
Refrigeration unit must be plug-in type for easy
operation
Must be Trolley-mounted for easy shifting
8.Ozone Generator:
SI. no.
Technical Specifications
Technical Specification quote
d by bidder
 Required for for de-odourisation and disinfection of Morgue
 Each Ozone Generator de-odourises approx. 350 to 450 sq. m
area with 3.6 m roof height
 Ozone generation & delivery rate should be at least 1000
mg/hr
 Residual Ozone in atmosphere should be 0.1 – 0.125 ppm
 Must be plug-in type for easy operation
 Power consumption should be below 40 watts
 It has to be Blower-type, not solely sparker type.
 No perfume should be used in the input
 Should be easily serviceable locally
 Preference will be given to concerns having previous
experience in this field
 Company or Product should be certified by ISO / appropriate
authorities
Demonstration may be sought for before placing purchase order
24
Bidders
deviation if any
9. Deadbody Weighing Machine / Cadaver Weighing Scale:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if
any
Technical Specification quote
d by bidder
Bidders deviation
if any
 Size of Platform / Weighing Plate: 5 – 6 ft. (length) × 3 – 4 ft.
(breadth)
 Range: Upto 200 kgs
 Platform should be made of Stainless Steel (preferably SS 304
grade) for easy cleaning and anti-staining
 Must have rust-proof coating paint
 Must be plug-in type for easy operation
 Must be Trolley-mounted for easy shifting
 Accuracy 5 – 10 gms.
 Display should be digital and preferably also with an Analogue
back-up
 Preferable to have a rechargeable Battery back-up for usage in
power failure
 Should be easily serviceable locally
 Demonstration may be sought for before placing purchase
order
Company or Product should be certified by ISO / appropriate
10. Viscerae / Organ Weighing Machine
SI. no.
Technical Specifications
 Size of Platform / Weighing Plate: 1 – 1½ ft. (length) × 1 – 1½
ft. (breadth)
 Range:Upto 10 kgs
 Platform should be made of Stainless Steel (preferably SS 304
grade) for easy cleaning and anti-staining
 Must have rust-proof coating paint
 Must be plug-in type for easy operation
 Must be Trolley-mounted for easy shifting
 Accuracy 1 – 5 gms.
 Display should be digital and preferably also with an
Analogue back-up
 Preferable to have a rechargeable Battery back-up for usage
in power failure
 Should be easily serviceable locally
 Demonstration may be sought for before placing purchase
order
Company or Product should be certified by ISO / appropriate
authorities
25
11. Autopsy Saw (Electrical):
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if
any




Must be based on High-Speed-Oscillating-Action principle
Must be plug-in type for easy operation
Electrical cord must be 8 – 10 ft. long
The set should be equipped with a large no. of blades plus
at least 2 arbors
 Grip area should be comfortable for a firm grip
 Switch for On/Off, preferably Sliding type should be placed
on the body of the instrument
 Demonstration may be sought for before placing purchase
order
 Should be easily serviceable locally
Company or Product should be certified by ISO / appropriate
authorities
12. Autopsy Instrument Box:
SI. no.
Technical Specifications
Each Box must contain at least the following
instruments –
•
Cartilage Knife (6-9 cm blade)
•
Mallets (18 – 22 cm)
•
Operating Knives (various sizes having 12 – 18
cm blades)
•
Amputation Knife
•
Rib shears (Rt & Lt)
•
Probe
•
Rachet (18 – 22 cm)
•
Toothed Forceps
•
Forceps without tooth
•
Scissors
•
Resection Saw
•
Spare Blade for Saw
•
Retractor
Demonstration may be sought for before placing
purchase order
Should be easily serviceable locally
Company or Product should be certified by ISO /
appropriate authorities
26
13. Autopsy Table:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
 Size of Platform: 7 – 10 ft. (length) × 3 – 4 ft. (breadth)
 Carrying Capacity: Upto 200 kgs
 Platform should be made of Stainless Steel (preferably SS
304 grade) for easy cleaning and anti-staining
 Height must be adjustable from 2.5 to 3.5 ft
 Circumferential perforation must be present for disposal
of wastes
 Should be fitted with wash basin / sink at one end
 Hand sprinkler must be fitted with basin for easy
washing
 Should be easily serviceable locally
 Demonstration may be sought for before placing
purchase order
Company or Product should be certified by ISO /
appropriate authorities
14. Automated tissue processor:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Essential
One basic instrument consisting of 10 reagent containers
each having a capacity of 1.8 liters, 2 wax baths of 1.8 liter
capacity, one standard metallic tissue basket containing 80
cassettes, 2 sets of replacement fuses, one set of power cord.











Carousel type construction with 12 station (10
reagent station, 2 wax bath)
Membrane keypad and LCD screen.
Audible alarm warning in case of error message and
completion of tissue processing cycle.
Power failure indication including station number
and time lapsed in excess of programmed
infiltration time.
Voltage 100 – 240V/50-60Hz
Infiltration time of up to 99 hr 59 minutes & should
be separately programmable, for each station.
Preferably 1 minute drain time between stations for
reduced carry over.
Temperature range of wax baths 45°C to 65°C.
Excess temperature cut out 75°C.
Automatic reheating of wax before basket transfer
to a wax bath.
Easy editing and changing of programmes even
during a processing run.
Should have Kolkata based excellent service back-up
with readily available spares and certificate from
manufacturers for availability of spares for a
27
Bidders
deviation if any
minimum period of 5 years from the date of
installation.
Suitable Voltage Stabilizer must be supplied.
3KVA online UPS with at least 30 minutes back up
must be supplied along with the instrument.


Desirable



Safety feature for automatic immersion of tissue
basket in a station in case of mains power failure.
Option for manual raising and rotation of carousel
for immediate tissue basket removal or transfer to
the next station – using crank.
Both immediate and delayed start option (up to 7
days or more) must be available.
15. Grossing Station:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Essential














Stand alone models ergonomically
designed to be low to the counter.
Abundant fluorescent light is directed to
the work surface.
Rapid positive drainage
Vacuum breaker-protected water supply
External Exhaust ventilation
Fume removal is efficient and quiet.
Noise levels measure less than 65 decibels.
Appliances plug into the unit for
convenient use.
Two hospital-grade duplex ground fault
circuit interrupter (GFCI) receptacles or
Four IEC 320 receptacles
Back draft design for efficient capture of
fumes across the work surface.
Programmable microprocessor allows clock
time to be changed or the filter
replacement alarm to be reset.
Flat stainless steel work surfaces include
three removable perforated grid plates •
Each unit with a magnetic instrument bar,
two integral centimeter rulers, tea strainer,
and paper towel dispenser.
Installation is quick and easy.
Movable acrylic splash shield protects the
user from sprays and splashes while
dissecting specimens.
28
Bidders
deviation
if any
























Stand-Alone Model Physical Specifications
Dimensions (H x W x D): Overall: Not more
than 8’ X 4’ X 2.5’
Work Surface Height: Not more than 36”
Right-Hand Sink: 14” x 12” x 10”
Electrical Specifications
• Two IEC 320 Power Entry Modules
and two point-of-use power cords.
• 110-120V models draw 15 amps
including the two hospital-grade
duplex ground fault circuit
interrupter (GFCI) receptacles.
• 220-240V models draw 15 amps
including the four IEC 320
receptacles with facility-supplied
residual current device (RCD)
protection required.
Plumbing Specifications
• Two 1/2” industrial-grade flexible
hoses with 3/4” female hose fittings
are supplied for connection to cold
and hot water supply lines.
• 1 1/2” I.D. reinforced flexible hose is
supplied for connection to facility
drain line.
External Exhaust via Integral Blower and
20' Max of Facility Duct
Tea Strainer Faucet (same as water faucet)
—
Type 304 Stainless Steel Tabletop and
Panels —
Upper and Lower Shelves —
Fluorescent Light —
Tea Strainer
Movable Dictation Machine Rack
Sharps Container
Tower Bar and Dispenser
Magnetic Instrument Bar
Movable Splash Shield
Uni-Capsettes
C-fold Towels
Centimeter Rulers (2 at least)
Perforated Grid Plates
Stainless Steel Base with Tubular Frame
and Cabinet
1/2 hp Disposal
Manually-Controlled Cold / Hot Water
Faucet and Disposal
29


Hand Spray Combined with Faucet
Replacement Filters should include 2
potassium permanganate filters and 2 fine
particle filters
Desirable
 Vinyl Cutting Pad
 Side Splashes
 Formalin Dispenser
 Movable Requisition Rack
 Magnifier on Flexible Arm
 Magnetic Instrument Bar
 Formaldehyde Neutralizer Pads
 Magnifier Lamp (110-120V/220-240V)
 Adjustable Height Stand with Shelf - 28” 42”
 Foot Pedal-Controlled Faucet
 Camera Bracket
 Monitor Bracket
16. Dual Head Trinocular Microscope with Photomicrographic Attachment:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Essential
Microscope





Optical system: UIS2 (Universal Infinitycorrected) optical system
Illumination: Built-in transmitted Koehler
illuminator; 6V30W halogen bulb; 100120V/220-240Vg 0.85/0.45A 50/60Hz
Focusing:
o Stage height movement by roller guide
(rack & pinion)
o Stroke per rotation: 36.8m
o Full stroke range: 25mm
o Upper limit stopper
o Tension adjustment on coarse focus
adjustment knob
Revolving nosepiece: Fixed quintuple nosepiece
with inward tilt
Observation tube:
o Type: Dual observation attachments
with one head trinocular and the other
binocular
30
Bidders
deviation
if any
o
o
o
o




Field number 20
Tube inclination 30º
Interpupillary distance adjustment
range 48—75mm
Light path selector: None (Bi 50%,
Video/Photo 50% fixed)
Stage
o
Movement range 76mm X-direction X
50mm Y-direction
o Specimen holder: Double slide holder
o Rubber grip: Equipped as standard
Condenser
o Type: Abbe condenser
o N.A. 1.25 with oil immersion
o Aperture iris diaphragm: Built-in
Objectives
Plan, Achromatic, 4X, 10X, 20X,
40X, 100XO
Eye piece
Wide field 10X, F.N. 20 with
pointer
Accessories:

Imported CMOS Camera (5MP)











CMOS Sensor -1/2.5'' MT9P001, color
Sensor Resolution-2592x1944, 5Mpix
Pixel Size - 2.2umx2.2um
Sensitivity - 1.4V/lux-sec 550nm
A/D Conversion - 12bit
S/N Ratio - 40.5dB
Exposure Time - 0.083-378ms
Frame Rate 6fps@2592x1944/22.8fps@640x480
Spectral Response - 390-750nm
Readout Noise - 8 eScan Mode - Progressive Scan


Shutter - Electronic
Optical Interface - C/CS mount

Data Interface - USB2.0 (480 Mbit / sec)

Power Supply - DC 5V ± 5%

Power Consumption - approx. 2W

Operating Temp - 0°C ~ 60°C

Operation System - Windows 2000/ XP / Vista /
31




















Windows 7 (32bit/64bit)
Software Specification:
File Format Support: Still Image File: *.bmp
*.gif *.ico *.jpeg *.jpg *.mng *.pbm *.pgm
*.png *.ppm *.svg *.svgz *.tga *.tif *.tiff *.xbm
*.xpm
Video File: AVI, Microsoft Excel file (*.xls), PDF
file (*.pdf), Image Print Out
Imaging:
Colour: AWB (Auto White Balance), MWB
(Manual White Balance), Enhancement of Each
Channel, Gamma, Saturation, Contrast;
Exposure: Auto Exposure, Exposure Target,
Exposure Time, Enhancement
Horizontal/Vertical Flip, Monochrome Mode,
Bit width Setting (hardware needed), Frame
Rate Setting (hardware needed), Light
Frequency Setting (hardware needed),
Raw2RGB Algorithm Setting (hardware
needed), Preview/Capture Resolution Setting,
ROI
Capture:
Capturing/ Video, Histogram Real-time View
Processing:
Brightness, Contrast, Gamma, RGB, Hue,
Saturation Adjustment, Counter-colour
Processing, Mosaic Processing, Image Gray,
Remove Noise, Sharpen, Smooth, Edge Filter,
Morphology, Geometric Transform:
Vertical/Horizontal Flip, 90, 180, 270 Rotate,
Arbitrary Rotate
View:
Zoom In/Out, Original, Window Fit, Full-Screen
Mode, MMB Zoom, Indicatrix
Measurement:
Point, Distance, Polaiea, Rectangle, Ellipse,
Circle, Arc, Angle, Continuous, Annotation
Operation: Select, Move, Edit, Delete; Colour
Setting: Line, Words, Font
Live Measurement
Calibration, Save Calibration Data
Excel Output
Application:
Image Tiling, Fluorescence (Separate &
Multiply)
32
17. Specimen Jar(Rectangular) with Cover for Museum:
SI. no.
Technical Specifications




Technical Specification quoted
by bidder
Bidders
deviation
if any
Glass type:
o Low alkali borosilicate type 3.3 glass
with low thermal expansion.
o Free of arsenic, magnesia – lime – zinc
group, resistant to water, neutral and
acid solutions, concentrated acids,
chlorine, bromine, iodine and organic
matters.
o Clear and colourless.
Glass Jar size:
1. 200 X 125 X 100 mm
2. 250 X 250 X 120 mm
3. 320 X 175 X 100 mm
Glass plate of jar sizes
Glass rod as per jar size
18. Adult nasal endoscopes:
SI. no
.
Technical Specifications
Technical Specification quoted
by bidder
1.Adult nasal endoscopes0-degree-1 such
30-degree-1 such
45-degree-1 such
70-degree-1 such
Length-18 cm
Diameter- 4mm
33
Bidders deviation if
any
Wide angle
19. Paediatric nasal endoscopes :
SI. no
.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation if
any
2. Paediatric nasal endoscopes
0-degree-1 such
30-degree-1 such
45-degree-1 such
70-degree-1 such
Length-15 cm
Diameter-2.7 mm
Wide angle
20. Automated Microbial Growth Detection System:
SI. no
.
Technical Specifications
Technical Specification quote
d by bidder
a) The system should be for minimum
of 50 positions.
b) The system should be fully
automated and should be capable
of detecting
growth
of
the
pathogenic
microorganisms form blood and sterile
fluids
(should be US-FDA approved).
c) The system should be able to detect
fungal, aerobic and anaerobic
organism from the blood.
d) The system should have the
capacity to process samples of adult
34
Bidders deviation if
any
and pediatric patients and should
have dedicated media for pediatric
samples.
e) The system should have the
capability of continuous monitoring
of the
f) clinical samples.
g) It should have automated
continuous instrument quality check
facility
h) The system should be able to
display growth kinetics on the
screen. The
system should be modular and
upgradeable for future requirements
i) The system should have the
capacity of analyzing and detection
of delayed entry of specimens at
growth, stationary and decline stage
(both log & lag phase)
j) The media provided for blood,
sterile body fluid or fungal culture
should be
provided with additional
antimicrobial substances
k) Detection principal of the system
should not have any bottle
puncturing
during sample analysis and thus no
dangerous aerosols formation
l) System should allow random
loading of bottles in any position
and should
allow loading of bottles without
any software intervention (if
required)
m) Media bottles should be made of
safe materials and should comply to
Occupational safety guidelines
n) System should individual detection
device for each position and should
allow extension of no of incubation
days for any specific position.
21. Automated Mycobacterium Growth Detection System :
SI. no. Technical Specifications
35
Technical Specification quoted
by bidder
Bidders
deviation
if any
a) The system should be for minimum of 50
positions.
b) The system should be fully automated and
should be capable of detecting
Mycobacterium from all clinical specimens -respiratory and non-respiratory: sputum,
urine’s, lavage’s, biopsies, spinal and other body
fluids.
c) The system should have the capability of
continuous monitoring of the
clinical samples.
d) It should have automated continuous
instrument quality check facility
e) The system should be able to display growth
kinetics on the screen. The
system should be modular and upgradeable for
future requirements.
f) The system should have the capacity of
analyzing and detection of delayed entry of
specimens at growth, stationary and decline
stage (both log & lag phase).
g) Detection principal of the system should not
have any bottle puncturing
during sample analysis and thus no dangerous
aerosols formation.
h) System should allow random loading of bottles
in any position and should
allow loading of bottles without any software
intervention (if required)
i) Media bottles should be made of safe materials
and should comply to
Occupational safety guidelines.
j) System should individual detection device for
each position and should allow extension of no
of incubation days for any specific position.
22. TRINOCULAR MICROSCOPE WITH INFINITY CORRECTED OPTICAL SYSTEM WITH
ATTACHMENTS:
SI. no.
Technical Specifications
FLUORESCENCE
Technical Specification quoted
by bidder
a) Microscope frame with trinocular
tube, quintuple revolving nosepiece,
mechanicalstage (right handle), abbe
condenser, 30W illuminator, filter
32.5C-2
36
Bidders
deviation
if any
b) Power cord
c) 30W Halogen bulb (Philips No. 5761)
and LED illumination provition
d) Trinocular tube, FN20, fixed light
pass,
e) Wide field eyepiece 10X, FN20
f) Brightfield condenser, N.A. 1.25, with
A.S. vernier scale
g) Attachment lens for condenser CH3CD, CH3-CDP, CX-SLC
h) Plan achromat objective 4X/0.1, WD
18.5, Plan achromat objective
10X/0.25, WD 10.6, Plan achromat
objective 40X/0.65, WD 0.6 (spring),
Plan achromat objective 100X/1.25,
WD 0.13 (spring, oil)
i) Immersion oil 8cc
j) Dust cover Type 015 for CX21/31/41
( L 450mm x H 460mm)
k) Infinity Optics providing image
flatness, Seidentopf observation
head for individual choice of
adjustment, Anti-fungus treatment
for component durability, High
eyepoint design eyepiece (F.N.20),
Interchangeability of Objectives, the
abbe condenser & the light relay
system fitted with high performance
aspheric lenses for bright & uniform
illumination, Window in arm & the
Ergonomic design for user
convenience, Illumination system
through SMPS circuit for constant
voltage output, Rackless stage for
durability and ease of use
l) 3 watt LED (light emitting diode)
reflected fluorescence attachment
a) High efficiency illuminator
for Reflected light
fluorescence (clamps directly
on microscope stand
allowing also transmitted
light brightfield microscopy),
37
can switch to light
microscopy without
detaching the fluorescence
module
b) 2 positions filter slider &
Transport box alongwith
c) Variable light control to
adjust intensity
d) Green LED cassette with
excitation wavelength
535nm, long pass 575nm
emission filter.
e) Royal Blue LED cassette with
excitation wavelength 450
nm, long pass 510 nm
emission filter.
f) 1.4 mega pixel Camera (for Tr) (for
BF / Fluorescence Microscopy) with
in Built 1/2" Sony CCD Sensor,
15fps@ Resolution 1360x1024,
Binning 1x1 , White balance
adjustment , ultra fine colour
engine, Power supply DC5V over PC
USB port , Support windows 7/8 (32
& 64 Bit) and Supplied with 0.5X C Mount Tr-adapter.
23. Media Preparation System:
SI. n Technical Specifications
o.
Technical Specification quoted
by bidder
a) Autoclave Stainless steel cuvette of capacity 110 liters.
b) Sterilization cycle variable from 100 to 121
deg.C for 10-30 minutes as per requirement
c) Provision for preparing at least 5 different
culture media in a day
d) Provision for temperature cycles for
preparation of chocolate blood agar and
incorporation of additives like blood, serum,
38
Bidders
deviation
if any
antibiotics and other selective agents
e) Media pouring temperature range of 35 to 80
deg.C
f) Preparation time for 5 liters of medium not
more than 90 minutes
g) LED/LCD display for programme settings and
monitoring progress of the procedure
h) Selectable stirring at 50-200 RPM forward and
reverse direction.
i)
Interface 2 x RS232, Ethernet, AUX contact,
RS232
24. Automatic Pourer and Stacker:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
a) The system should have pouring speed of
more than 450 plates per hour.
b) The system should have a stacker to
automatically dispense empty plastic petri
dishes.
c) The plates should be opened for very short
period for dispensing.
d) Any consumable used for filling should be
autoclavable before reuse.
e) The system should have cooling device –
either built in or provide separately (price to
be quoted if provided separately).
f) The system should have agar spread
function for homogeneous distribution.
g) The system should have intuitive and easy to
use screen.
h) The system should have flexibility to process
39
Bidders
deviation
if any
either 55mm, 90 mm plates .
25. Automated Tube Media Dispenser:
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
a) The system should standardize the media
dispensing to either plates, tubes and
bottles.
b) The system should be user-friendly.
c) The system should be easily convertible for
dispensing into either tubes or bottles
d) The system should have capacity to load
minimum 450 tubes at any time.
e) The system should racks to accommodate
tubes and bottles of different size.
f) The system should have in-built auto
positioning capability of dispensing tip.
g) The system should have a keypad for easy
entry of related information.
h) The system should be programmable for
different dispensing options.
i) The system should have compact design.
40
Bidders
deviation
if any
26) . 800mA X-ray R/F System with IITV
SI. no.
Technical Specifications
Technical Specification quote
d by bidder
The equipment shall be the latest state of the art
technology High end Radio fluoroscopy system capable
of multipurpose diagnostic procedures like GI
Procedures, ERCP, Endoscopies, nonvascular IVR,
Urological and orthopedic examinations and all
extremities. The system should consist of Patient table
with X-ray system of II TV, SFD, over coach X-ray Tube,
control operation from remote control room as well as
from Tableside etc. as an integrated configured system.
X-ray Table:
Remote controlled R/F x-ray table with full auto-SFD
The Patient should be accessible from the back and
front of the table
Motorized tilting facility +90/at least -15 degrees
Full coverage of patient anatomy should be possible
without repositioning the patient
Imaging unit should travel at least 90cm.
Table should bear at least 130 Kg weight.
Mention tabletop lateral travel range
Table X-ray absorption should be low
Tube swing out 180 degrees should be there for Chest
Radiography etc.
Motorized remote driven Compression cone to be there
in the table
Chest stand with vertical Bucky with oscillating grid
should be available.
Spot Film Device
Spot film device should be electronically controlled
auto-sensing and displaying the cassette format and
operation
Grid ratio 12:1 with 60 lines/cm.
Cassette format shall be possible from 8”X10” to
14”X14”, 8”X10” to 14”X17” format will be preferred
41
Bidders
deviation if any
along with sub-divisional (up to 4 division) spot
radiography
X-ray generator
X-ray generator should be capable of handling minimum
80KW with automatic exposure control for high contrast
level of Image Quality
It should be latest technology High-frequency Inverter
type with at least 50 KHz or more
Generator out put voltage from 40KV to 150 KV
Radiography mA 800mA at 100KV and as low as 10mA
Minimum time Radiography exposure should be 1mSec.
and maximum up to 10 sec.
Pulse fluoroscopy facility for X-ray dose reduction at
least 15 fps
Continuous fluoroscopy time up to 10 minutes with
alarming buzzer.
Fluoroscopy KV range should be up to 125KV
Anatomical program (APR) setting and selection of
minimum 50 numbers.
X-ray Tubes
Anode heat storage capacity should be 400KHU and
above.
Tube leakage radiation should be low
Tubes should be dual focus
AHU and focal sizes to be mentioned
II and TV system
Minimum 30 cm CCD based Image Intensifier in under
table position
Minimum 14” monitor for live and reference image
viewer
42
27.Assembly for isolated tissue experiment with (Dale’s organ bath)
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Dale’s single unit organ bath for isolated tissue
experiment with
-plexyglass water bath (minimum 7” height X 9 “
length X 6” width), at least
- glass inner organ bath (7” height X 1 “ diameter)
with side inlet
- long glass made oxygen tube with metallic tissue
holder (at least 7” long)
- metallic lever holder
-metallic oxygen tube holder
- heater with thermostat & metallic heating coil
-glass coil for connection to the buffer containing
container
-motor with metallic stirrer
-long frontal lever.
-Any other relevant accessories required for
standard isolated tissue experiments.
Name of the manufacturer should be specified
with model number.
28.Laboratory thermometer
SI. no.
Technical Specifications
Measures at least 0-100 degree C
29. Kymograph (Students) Electric independent unit
SI. no.
Technical Specifications
Electrical with super quality metal gears, cccurate
mill cut ratios with provision of engagement of
various ear ratios i.e. 640 mm, 320 mm, 25 mm,
12.5 mm, 2.5 mm, 1.2 mm, 0.25 mm & 0.12 mm
per sec, & effected by sliding lever into slots
marked with 8 surface speed. Speed change clutch
with intermediate off position.
43
30.Analytical balance
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Electronic balance with wide angle LCD display.
Equipped with filters to reduce vibration. Glass
enclosure with sliding doors on the three sides.
Features including automatic zeroing, selectable
units. Tare facilities.
-units of measurement- g, mg, oz etc.
-weighing capacity- 0.01 mg to gm (atleast)
-Power supply 220/240 V, 50 Hz
-water proof keyboard
31.LCD projector
SI. no.
Technical Specifications
2000 lumen, 3 LCD panel, 1.2 times zoom lense
with autofocus, 165 watt UHP lamp screen size
coverage 40"X 150". Name of the
manufacturer should be specified with model
number.
32.Glass pill tile
SI. no.
Technical Specifications
Perfectly level surface. ¼” thickness,
10”X12”. Corners rounded.
33.Porcelain pill tile
Technical Specifications
44
Perfectly level glass. ¼” thickness,
10”X12”. Underside graduated up to 30”
units (one side). Corners rounded.
34.Laser Printer, scanner. Copier for office &PvP
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation
if any
Black and white printer, colour scanner,A4 print
speed up to 25 ppm, monthly duty cycle 10,000.
Name of the manufacturer should be specified
with model number.
35.Reagent bottle
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation if
any
Glass made, wide mouth( 4 cm), 200ml capacity
36.Measuring cylinder
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
12 inches length. Width 1.5 cm
37.Measuring cyllinder
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation
if any
Quality glass made, 100ml capacity
38.Steel spatula
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
12 inches length with handel one end.
45
Bidders deviation
if any
39.Steel spatula
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders deviation
if any
6 inches length with a scoop at one end (scoop
diameter 0.5-1 cm)
40.Glass funnel
SI. no.
Technical Specifications
6 inches length with inside diameter of 2cm
41.Polypropylene Mice Cage
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Cage top- 410mmx360mmx240mm
Body-Thickness-4mm, weight-1200 gms approx
Top grill-S.S. grade 304, mesh size55mmx6mmx14swg welded on 4 mm
rod; provision for fixing water bottle; keeping feed
in V shaped hopper,
hanging cage card, two hooks to fix top grill.
Water bottle- - 300 ml, unbreakable Polypropylene
with a central S.S. nozzle with internal dia 6-8mm.
Note- Sample should be of S.S. grade 304
Guarantee against rusting or breakage for at least
three year
- Name of the manufacturer should be specified
with model number.
42.Polypropylene Rat Cage
Cage top- 290mmx220mmx140mm
Body-Thickness-4mm, weight-850 gms approx
Top grill-S.S. grade 304, mesh size25mmx5mmx14swg welded on 4 mm
rod; provision for fixing water bottle; keeping feed in
V shaped hoppe,
hanging cage card, two hooks to fix top grill.
Water bottle- 300 ml, unbreakable Polypropylene
with a central S.S. nozzle with internal dia 6-8mm.
46
Bidders
deviation if any
Note- Sample should be of S.S. grade 304
Guarantee against rusting or breakage for at least
three year
- Name of the manufacturer should be specified with
model number
43.Cage for guineapig(S.S.)
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders deviation
if any
Made of steel body duly powder coated or stainless
steel. With feeding bottle and feeding bowl, the
removable waste collecting tray below the cage
Size =18” x 18” x 20”
- Name of the manufacturer should be specified
with model number.
44.Cage for rabbit (S.S.)
SI. no.
Technical Specifications
Made of steel body duly powder coated or stainless
steel. With feeding bottle and feeding bowl, the
removable waste collecting tray below the cage size
:
-24” x 24” x 18”
- Name of the manufacturer should be specified
with model number.
45.T. table for small animal (S.S.)
SI. no.
Technical Specifications
Hydraulic manual type
- Name of the manufacturer should be specified
with model number.
47
46.Rat restrainer
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders deviation
if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Broome Restrainers for fast and easy animal insertion.
Transparent acrylic plexyglass made cylindrical design.
Sliding adjustable nose piece. Arrangement for
exposure of the whole tail after insertion of the
animal. Size is such that it should be sufficient for
restraining 70- 125 gm rat.
- Name of the manufacturer should be specified with
model number.
1
47.Mouse restrainer
SI. no.
Technical Specifications
Broome Restrainers for fast and easy animal insertion.
Transparent acrylic plexyglass made cylindrical design.
Sliding adjustable nose piece. Arrangement for
exposure of the whole tail after insertion of the
animal. Size is such that it should be sufficient for
restraining 30-70 gm mice.
- Name of the manufacturer should be specified with
model number
48.Animal weighing mechine.
SI. no.
Technical Specifications
Digital veterinary weighing scale (for small animals).
Capable of weighing small animals
10 grams to 3 Kg (approx.)
Name of the manufacturer should be specified with
model number.
49.Room Heater
SI. no.
Technical Specifications
800- 1200 Watt.
With thermostat control.
Minimum three Heat setting
Domestic type
Wheel for easy mobilisation
Radiation type
With fan
48
50.Horizontal Electrophoresis Apparatus with Power Pack
SI. no.
Technical Specifications
1
Tank: Should be temperature/ corrosion proof with
no leaking point
2
Provision for automatically cut off electric field
when the lid is opened
3
At least 2 Gel casting trays with standard
dimension of 5 - 6 x 7 – 10 cm
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Technical Specification quoted
by bidder
Bidders
deviation if any
Safety lid should be provided
4
Power pack should have all necessary safety
provisions like Over load, No load, Sudden change
in load, power failure indication, safe plugs and
sockets
5
51.Centrifuge (8 tube)
SI. no.
Technical Specifications
1
Provision of Manual brake
2
Speed & time can be regulated
3
Capacity of tube can be varied
52.Double pan Balance
SI. no.
Technical Specifications
Should have weighing capacity of 200 gm with
accuracy up to 0.2 mg
53.Single pan electronic balance
SI. no.
Technical Specifications
1
Readability up to .001 g
2
Shield doors should open by sliding
3
Provision of easy calibration
49
54. Fully Automated Clinical Chemistry Analyzer
Sr.
No.
1
Technical Specifications
2
Throughput :> 350 Photometric tests, without
ISE. Note : Non-Compliance to this point will be
considered as major deviation.
Programmable Parameters : More than 90
Photometric Tests. 10 Calculation items.
Assay Modes : 1 – point, 2 – point, Rate – A
Rate – B
Calibration : Linear, Non-Linear, Multipoint
Sample Type : Serum, Urine, Other (Plasma,
CSF etc)
Sample handling : At least 50 primary tubes and
20 sample cups with continuous loading facility
available. Emergency Sample Up to 25 in
patient run.
Sample Container Type : Primary tube 5 ml,
7ml, 10ml or 2ml sample cup
Barcode reader : Optional (For sample &
reagent)
Reagent Tray : Cooled reagent tray with 50
positions.
Reagent pipetting : 10-300 µl, steps of 0.1 µl
Possibility of 1 or 2 reagent tests.
Sample Pipetting : 2-60 µl, steps of 0.1 µl
Reagent Bottle : 20ml, 50ml & special 5ml
adaptor tubes
Reaction cuvettes : Permanent glass cuvettes..
Note : Non-Compliance to this point will be
considered as major deviation.
Photometry: Multi-wavelength diffraction grating
with wavelength options at least 340, 415, 505,
570, 600, 700 & 750 nm.
Reading Volume : 200 µl or less.
System interface : Bi-directional, RS 232.
Power Supply : 230V ± 10%, 50/60 Hz, 1.0 KVA.
Computer (requirements): Instrument must be
interfaced with PC with microprocessor of at
least Core 2 Duo Configuration or higher along
with LCD monitor system and UPS 2 KV,
DVD/RW Drive & Laser Jet Printer.
Ambient Operating Temperature: 20o – 32oC.
Water consumption: Should not be more than 10
liters per run.
3 years warranty and AMC for next 2 years from
the date of installation. Certification: EC / FDA.
The cost of warranty & AMC must be
incorporated in the quoted price.
The instrument must have separate reagent tray
and sample handling tray.
There must be two separate robotic arms, one
dedicated for the sample withdrawal and
delivery to the glass reaction cuvette and other
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Technical Specification
quoted by bidder
System Configuration : Automated, Discrete,
Random access, Open System, Patient
Prioritized, Clinical Chemistry Analyzer
50
Bidders deviation if
any
one only will deliver reagent from the reagent
bottle. Note : Non-Compliance to this point will
be considered as major deviation and
disqualification in terms of technical
specifications.
55.VACUUM DELIVEY SYSTEM( Digital-LEDMODEL)
SI. no.
Technical Specifications
1
Vacuum Extraction Cups 50 mm with silicone
tubing, Vacuum Extraction Cups 60 mm with
silicone tubing and Silicone Vacuum Extraction
Cups 63 mm with silicone tubing, all with
different colour codes.
2
3
4
5
6
7
Technical Specification quote
d by bidder
Caesarian Aid Cup 60 mm all with different colour
codes.
Birds Modified metal cups 50mm Occipito
anterior (Stainless steel)
Birds Modified metal cups 50mm Occipito
posterior (Stainless steel)
Birds Modified metal cups 40mm Occipito
anterior (Stainless steel)
Birds Modified metal cups 60mm Occipito
anterior (Stainless steel)
Vacuum Extractor Machine–Electrically operated
with Foot switch controlled with SS Trolley.
51
Bidders deviation
if any
56. Anaesthesia Machine
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Essential features













Oxygen driven nitrous oxide regulator –
ensures zero nitrous oxide flow in case of
oxygen failure.
Audio (whistle ) alarm for oxygen failure.
Hypoxia guard with rotameter ensures
minimum oxygen flow of 21 % to 30% to
the patient.
Gas specific pin indexed avoid yoke and
other connections avoids chances of
accidental mix-up.
Pin indexed gas specific yokes with SS bar
clamp
Forged regulator each for oxygen and
nitrous oxide
Non-return cum blow-off valve to save the
vaporizer and rotameter from back pressure
Space for 2 two vaporizer halothane/ TEC
/2000 vaporizer and same is fitted as per
choice.
Common gas outlet with emergency oxygen
flush (35 L/min) and patient safety blowoff valve.
2.5 inches pressure gauge for oxygen and
nitrous oxide
Rigid powder coated MS/SS tubular
structure on wheels with break
Luminous black plate for rotameter
Overhead monitor shelf
Desirable feature:



Place for keeping 2 bulk cylinders in the
rear platform.
Provision for circle absorber attachment
One drawer
52
Bidders
deviation if any
57. CPR Training Manikin (Adult)
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Bidders
deviation if any
Essential features

This CPR Manikin is designed according to the
AHA Guidelines for CPR and EEC. The operation
standard: the AHA Guidelines for CPR and EEC.
 Airway Simulating: The Compression indicated
by Indicating lights, Counter and audio
instruction
 When the compression position is right on the
CPR Manikin, it will be indicated by the light,
which is located in the central position in the
chest, with green flash. And wrong position will
be indicated by red flash. The compression
times is indicated by the counter, which is
located on the left side of the monitor.
 To check the pulse of the cervical artery.#
Power supply: 220V AC puts in through power
adapter, and the output is 24V DC. The power
supply for the Report Printer is 9V.
Desirable feature:




Some procedures will be guided by audio
instruction.
A report is printed after practice
Mode: Training mode; Test mode
To check the pulse of the cervical artery
58. Multi-functional Airway Management Model
SI. no.
Technical Specifications
Technical Specification quoted
by bidder
Essential features :



Accurate anatomical marks
Oral or nasal cavity intubation
It allows observing the suction position
from side face so as to instruct correct
method of the intubation skill.
 Wrong operation, stomach inflation or
laryngoscope compressing the teeth will
activate warning prompting
Desirable feature:
53
Bidders
deviation if any
Carry & preservation case
59. Nerve Locator
SI. no.
Technical Specifications









Technical Specification quoted
by bidder
Local anaesthetic blockade of single nerves
or trunks
Constant current.
Bright, large, red led display to read clearly
from distance.
Selectable current range varying from 0 to
5.5 mA in steps of 0.1ma.
Wide range of energy levels & interval
setting.
Audio-visual indication for pulse delivery.
Low battery warning indicator.
Compact, light weight and user friendly.
Autoclavable leads
54
Bidders
deviation if any
Was this manual useful for you? yes no