B100PROX-EH-SA v2
B100PROX-MF-SA v2
EN
Standalone Biometric Reader
INSTALLER’S MANUAL
www.xprgroup.com
Rev. 1.01 - 07.04.2022
1
CONTENTS
1. INTRODUCTION
2. MOUNTING
3. SPECIFICATIONS
4. APPLICATION DIAGRAM
5. RECOMMENDED SWIPING TECHNIQUE
6. INDICATION
7. WIRING
8. ADDING ADMIN FINGER
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100PROX-SA v2 with DINRTT
Pairing B100PROX-SA v2 with RTT
Pairing B100PROX-SA v2 with RU2
10. ADMINISTRATOR PROGRAMMING
ADD finger relay 1
ADD finger relay 2
ADD finger relay 1&2
DELETE finger
DELETE ALL fingers
CHANGE ADMIN finger
CHANGE INSTALLER finger
Administrator programming block diagram
11. INSTALLER PROGRAMMING
Set relay 1 time
Set relay 2 time
BUZZER ON/OFF
BACKLIGHT ON/OFF
Installer programming block diagram
1. INTRODUCTION
B100PROX-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 99 finger templates and 2000 cards. One template is reserved for User manager (Administrator), one template is reserved for Reader configuration (Installer) and up to 97 templates are for Users.
This manual is used for both B100PROX-EH-SA (EM/HID Cards) and B100PROX-MF-SA (Mifare Cards).
www.xprgroup.com
2
5
6
4
4
4
4
2
3
7
7
7
7
11
11
11
11
11
12
9
9
8
9
9
10
8
8
8
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint.
If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations.
2. MOUNTING
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can’t be entered.
The operating temperature of the product is between 0ºC - + 50ºC. XPR™ cannot guarantee the functionality of the product if measures and advice before are not followed.
www.xprgroup.com
3
3. SPECIFICATIONS
Fingerprint Capacity:
Prox. cards Capacity:
Card Type:
Panel Connection
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Master/Admin Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Operating Temperature :
Operating humidity:
Dimensions(mm):
4. APPLICATION DIAGRAM
97 templates
2000 cards
EM or HID compatible (125KHz) - B100PROX-EH-SA or Mifare (13,56 Mhz; Classic 1K & 4K, Ultralight, Desfire) - B100PROX-MF-SA
Cable, 0.5 m
1 x Relay (2A/24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle (ON/OFF)
Finger or Card
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
Via RS-485 converter and windows application
150 mA max.
9-14 V DC
Tricolor Status LED
IP54 (internal use only)
0ºC to 50ºC
5% to 95% RH without condensation
100 x 94 x 30
5. RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
6. INDICATION www.xprgroup.com
4
7. WIRING
Wiring B100PROX-SA with magnetic lock
Wiring B100PROX-SA with electric strike
DIPSwitch settings www.xprgroup.com
5
8. ADDING ADMIN FINGER
1.Push dip switch no.2 in position ON.
2.Reset the Power of the device.
3.Wait for One long + multiple short beeps
4.Put the dip switch in position OFF. (short beeps will stop)
5.Wait for about 15 seconds for the LED to blink in Orange .
6.Swipe the Master finger min.6 times . (Until Ok Beep)
Warning: This procedure also deletes all the users, the installer’s finger, installer’s PIN Code and admin’s PIN Code.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2) www.xprgroup.com
6
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair (couple) both devices or refer to the Remote Relay’s Manual.
Pairing B100PROX-SA v2 with DINRTT
1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PROX-SA v2 with RTT
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red led blinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing B100PROX-SA v2 with RU2
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
www.xprgroup.com
1. Put the Jumper to closed position. RU2
beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long
beep)
After the OK beep, the coupling is done.
7
10. ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual.
ADD Finger Relay 1 (Finger that will activate on board relay 1)
Action
Swipe Admin Finger 1 time
Finger x 1
Backlight slow blinking
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or x 6 fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
ADD Finger Relay 2 (Finger that will activate remote relay 2)
Action
Swipe Admin Finger 2 times
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or
Finger x 2 x 6
Backlight slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
Action
Swipe Admin Finger 3 times
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep) or
Finger x 3 x 6
Backlight slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
www.xprgroup.com
8
DELETE Finger
Action
Swipe Admin Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe User Finger or
Present card/tag 1 time
Finger x 4 x1
DELETE ALL Fingers and Cards
Action
Swipe Admin Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times
Finger x 4 x2
CHANGE ADMIN Finger
Action
Swipe Admin Finger 5 times
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger min.6 times
CHANGE INSTALLER Finger
Action
Swipe Admin Finger 6 times
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger min.6 times
Finger x 5 x6
Finger x 6 x6 x 1
Backlight slow blinking fast blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Backlight slow blinking slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep short + long beep
Buzzer Sound short beep short beep multiple beeps
Buzzer Sound short beep short beep short + long beep
Buzzer Sound short beep short + long beep
3 short beeps www.xprgroup.com
9
ADMINISTRATOR PROGRAMMING BLOCK DIAGRAM
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu www.xprgroup.com
10
INSTALLER PROGRAMMING BY FINGER
Set Relay 1 Time (on board)
Action
Swipe Installer Finger 1 time
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger and start counting seconds
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode
Finger x1 x1 x1
Backlight slow blinking fast blinking fast blinking
Buzzer Sound short beep short beep beeps on 1 second short + long beep
Set Relay 2 Time
Action
Swipe Installer Finger 2 times
Finger Backlight Buzzer Sound short beep x2 slow blinking
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger and start counting seconds
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x1 x1 fast blinking fast blinking short beep beeps on 1 second short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
BUZZER ON/OFF
Action
Swipe Installer Finger 3 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Finger x3 x1
Backlight slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep
BACKLIGHT ON/OFF
Action
Swipe Installer Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Finger x4 x1
Backlight slow blinking fast blinking
Buzzer Sound short beep short beep short + long beep www.xprgroup.com
11
INSTALLER PROGRAMMING BLOCK DIAGRAM
Swipe the Installer Finger 1 to 4 times depending of the desired menu
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
www.xprgroup.com
12