Installation and operating instructions ENG CLED23 Examination light SYMBOLE; SYMBOLS The warning symbols indicate all instructions that are important for safety. Failure to comply with them can lead to injury, damage to the luminaire or the equipment. In combination with the following signal words the warning symbols means: DANGER Can lead to death or serious injury WARNING Can lead to injury Comply with operating Instructions CE conformity mark Protective earth, protection class I device Protection class II device Neutral conductor/return conductor for the electrical current Live conductor Storage humidity Storage temperature Disposal Manufacturer Date of manufacture Item number Batch code Serial Number 2 VARIANTS CLED23 T1C CLED23 TXPPS Contents 1 4 5 6 7 8 9 10 11 12 13 SAFETY INSTRUCTIONS ....................................................................................................................................... 4 1.1 Intended use ................................................................................................................................................. 4 1.2 User profiles ................................................................................................................................................. 4 1.3 Safety instructions ........................................................................................................................................ 4 1.4 Warning levels .............................................................................................................................................. 4 1.5 Specific mounting instructions ...................................................................................................................... 4 2 SCOPE OF SUPPLY .................................................................................................................................... 5 2.1 CLED23 T1C ................................................................................................................................................ 5 2.2 CLED23 TXPPS ........................................................................................................................................... 5 3 ASSEMBLY CLED23 T1C ............................................................................................................................ 5 3.1 Load data...................................................................................................................................................... 5 3.2 Attach ceiling bracket.................................................................................................................................... 5 3.3 Assemble the luminaire on ceiling tube ............................................................................................................. 7 ASSEMBLY CLED23 TXPPS .................................................................................................................................. 7 4.1 Load data...................................................................................................................................................... 7 4.2 Assembly ...................................................................................................................................................... 7 OPERATION ............................................................................................................................................................ 7 5.1 CLED23 T1C ................................................................................................................................................ 7 5.2 CLED23 ........................................................................................................................................................ 7 5.2 Transport position ......................................................................................................................................... 8 DISINFECTION CLEANING .................................................................................................................................... 8 SAFETY INSPECTIONS .......................................................................................................................................... 8 DEMOUNTING ........................................................................................................................................................ 9 8.1 Disposal ........................................................................................................................................................ 9 ACCESSORIES ....................................................................................................................................................... 9 ADDITIONAL INSTRUCTIONS................................................................................................................................ 9 TROUBLESHOOTING ........................................................................................................................................... 10 TECHNICAL DATA ................................................................................................................................................ 10 ELECTROMAGNETIC COMPATIBILITY (EMC) .................................................................................................... 12 3 ENG 1 SAFETY INSTRUCTIONS 1.1 Intended use med® The luminaire D CLED23 is an examination luminaire. Its intended use is to illuminate the body of the patient to support diagnosis or treatment. An interruption of the diagnosis or treatment caused by a light failure is always possible without a risk for the patient. The luminaire can not be used in operating rooms. 1.2 User profiles Medical professional A medical professional is any person who has completed medical training and is working in his or her professional field. Cleaning professional A cleaning professional is trained in national and jobrelated hygiene regulations. Electrician An electrician is trained in the fields of electronics and electrical engineering and is familiar with the relevant standards and regulations. Qualified professional A qualified professional is capable of mounting and dismounting the luminaire thanks to professional training, knowledge and experience and knowledge of the regulations. 1.4 The luminaire must not be covered by a cloth or any similar item while it is in operation. The ventilation openings (where they exist) must be free whenever the luminaire is in operation. The luminaire must not be operated near to external heat sources that exceed the maximum ambient temperature of the luminaire. The luminaire must not be used in environmental conditions other than those for which it is intended. The luminaire must only be used for the intended use described in this document. The manufacturer cannot be held responsible for any injury or damage that is caused as a result of any use other than the intended use or of any failure to comply with safety instructions and warnings. It’s recommended to protect the luminaire with an additional earth leakage circuit breaker. Warning levels DANGER Indication of hazards that can lead to death or serious injury if measures are disregarded. WARNING Indication of hazards that can lead to injury if measures are disregarded. CAUTION 1.3 4 Safety instructions Operation by a medical professional The instructions form part of the product. They must be stored and made accessible to all subsequent users. Any work on the luminaire (including repairs) must be carried out by qualified electricians only. Mounting must be performed by a qualified professional only. The luminaire must not be altered or manipulated in any way. Only approved original parts must be used. Any use other than the intended use with original parts may give rise to other technical values and life-threatening danger. Operation in potentially explosive areas is prohibited. The luminaire power supply is a potential ignition source. The luminaire must only be operated in dry, dustfree rooms. The luminaire must not be left switched on without supervision. For luminaires in protection class I, it is essential for the earthing conductor to be connected to the luminaire housing. Do not use any luminaire that is damaged. Defective cables are also potential hazards. Do not place the cable close to any heat source or on sharp edges. Damage to the eyes. Never look directly into the light source. Replace any glass that is damaged before operating the luminaire again. In order to prevent electric shocks, only connect the luminaire to a power supply with an earth conductor (only C-version). Never place additional loads on the luminaire head or the arm. Indication of hazards that can lead to damage to property if measures are disregarded. 1.5 Specific mounting instructions CLED23 T1C Mounting material is not included. The ceiling mounting must only be fixed to ceilings that have a concrete stability class B25 (C20/25) or higher. Solid ceiling reinforcement parts must not come into contact with the ceiling mounting. If there is any doubt, an authorized professional must confirm that mounting is possible on the mounting base being used. Borings must be made by specialists in compliance with the boring tolerances for the reinforcement anchor that have been approved by the manufacturer. Screws must be tightened carefully using a torque key that complies with the instructions of the reinforcement anchor manufacturer. CLED23 TXPPS Mounting material is not included. When using the accessory "wall mount", the installation must be done by a professional. The wall must ensure a firm hold. Use only mounting material which is suitable for the corresponding substrate. ENG 2 SCOPE OF SUPPLY 3 ASSEMBLY CLED23 T1C 2.1 CLED23 T1C 3.1 Load data Bending moment MB 25Nm Vertical weight FG 90N 3.2 Attach ceiling bracket DANGER Assembly by qualified personnel Assembly must be carried out by qualified personnel only. Lack of appropriate knowledge could be life-threatening. DANGER Life-threatening danger from falling luminaire. The ceiling must be made of solid concrete to guarantee a secure hold. A: B: C: D: E: 1x ceiling bracket 1x ceiling cover 1x end ring 1x ceiling tube incl. cable 1x luminaire with adaptor (pre-assembled) 2.2 CLED23 TXPPS DANGER Electric shocks are life threatening 1x Luminaire 1x Power cable The luminaire must be separated from the mains by an external all-pole switch. Pay attention to the minimum distance of the ceiling tube! Saw ceiling tube to the desired length at the top end using a metal saw and deburr. Remove fastening screw. Insert ceiling bracket 1 into ceiling bracket 2 and drill with d= 9mm 3. Use the existing hole in the ceiling bearing as a guide. 5 ENG Make 4 opposited bore hole markings (Ø13mm), consider the position of the Ø60mm bore for electrical connections Check clearances Disassemble the securing element from the ceiling tube (Allen wrench is enclosed, do not lose the threaded pin!) Insert the cable (with loose ends first) and pull up to the stop Pull the luminaire cable of the ceiling tube through the luminaire mount. Insert ceiling tube into luminaire mount Secure using the M8 safety screw and nut 1 DANGER Risk of injury from falling parts The ceiling bracket must be secured to the fastening material, that must be suitable for the corresponding ceiling condition. DANGER Risk of injury from falling parts Mounting must be performed by two people. CAUTION Use protective equipment in line with tool manufacturer's instructions Hold the ceiling bracket against the ceiling and strike the ceiling anchor with a hammer Tighten fastening in line with manufacturer's data Drill the bore holes, then blow them out using bellows DANGER Risk of injury from falling luminaire The ceiling must be made of solid concrete to guarantee a secure hold. Use suitable ceiling anchors. Tighten M8 safety screw and nut 1 (20 Nm / 14.75 lbf ft) Tighten all 4 threaded pins 2 (5 Nm / 3.68 lbf ft)) DANGER Mortal danger from electric shock 6 Disconnect or remove fuses before carrying out any work on the power connection ENG 4 ASSEMBLY CLED23 TXPPS 4.1 Load data Bending moment MB 25Nm Vertical weight FG 20N 4.2 Make power connection Assembly The luminaire are equipped with an adapter pin. The luminaire must be positioned in one of the accessories described in chapter 9. 5 OPERATION 5.1 CLED23 T1C DANGER Electric shocks are life-threatening Connect the secondary cable to the conncection point Pay attention to the polarity: + = red = brown – = blue 5.2 Only connect to a mains power supply with a protective conductor CLED23 DANGER Electric shocks are life-threatening Push cover and end ring over the ceiling bracket and tighten them (0.5Nm) Do not insert any power cable that is damaged. If there is any sign of damage to the power cable, replace it immediately with a new one. The connection voltage and frequency must match the data on the type plate. 3.3 Assemble the luminaire on ceiling tube WARNING WARNING The luminaire will fall if fastening is done incorrectly Risk of eye damage Never look directly into the beam of light. The securing element must be screwed in completely and correctly. Insert power cable to the luminaire Connect the cable with the mains Perform a function test before every use: All LED’s in the light cone must illuminate. Switch the LED module on/off Insert the luminaire and the adapter 1 into the ceiling tube 2 Insert securing element with threaded pin 3 and screw in to the stop Loosen by one quarter-turn to ensure the function of the turnover axis 7 ENG CAUTION Damage to property caused by incorrect cleaning Set the desired colour temperature according to the following table: COLOUR COL. TEMP. RECOMMENDATION blue cold white Ideal for identifying individual vessels for wound follow-up treatment and small procedures Ideal for various types of skin examinations orange warm white Use only disinfectants that will not affect the functional capability of the luminaire. No cleaning agents containing alcohol, solvents, chlorine or abrasive products must be used. Those agents can cause damages in the plastic parts. The cleaning and disinfection agents must be suitable and approved for plastics like PC, PMMA, PA and ABS. Concentrated disinfectants may damage the cover. Pay attention to the specifications from the data sheet of the agent for concentration and residence time. Unsuitable cloths can cause scratches. NOTE Dirt decreases luminosity 5.2 Clean regularly to keep the screen clean. Disinfection only by wiping is permitted. Set the desired Illuminance in 25% dimmer steps Transport position Clean the PA screen with a not abrasive cleaning cloth and a suitable cleaning agent. CAUTION 6 Transport the luminaire only in this position. To minimize the risk of disease transmission, in addition to complying with this instruction for use, you must also comply with the applicable occupational health and safety regulations and the requirements of national bodies with responsibilities for hygiene and disinfection. DISINFECTION CLEANING DANGER 7 DANGER Electric shocks are life-threatening Remove the plug from the mains before the disinfection cleaning. SAFETY INSPECTIONS Electric shocks are life-threatening Remove the plug from the mains. The connecting cable must be checked for damage at least once per year. NOTE 8 Maintenance and repairs must only be carried out by qualified electricians. The corresponding user profile is described in Chapter 1, Safety instructions ENG 8 DEMOUNTING DANGER Electric shocks are life-threatening 8.1 Remove the plug from the mains before demounting. Disposal Do not dispose the luminaire in household refuse. Dispose the luminaire at a disposal point in accordance with local regulations or take them to a dealer that provides an appropriate disposal service. Cut off the cable directly on the housing. The products listed above are more than 95% recyclable. The luminaires have been constructed to be compatible with recycling so that a high proportion of the materials used in these products can be recycled or converted into energy after the end of service life. They contain no materials that are dangerous or that need to be monitored. 9 ACCESSORIES Description Item code 16mm MOBILE BASE HWSCAM14255 COOLVIEW WALL BRACKET ASSEMBLY CABW14271 Rail Mount Bkt 16mm CABKTR16 1 Meter Medirail kit. Boxed with endcaps CABKTRAIL 16mm Desk Clamp OABKT16D 10 ADDITIONAL INSTRUCTIONS The luminaire itself is maintenance-free. You can obtain additional documents about this product from the manufacturer upon request. These luminaires do not affect any other devices. To save energy, the luminaire should only be switched on when actually needed. 9 ENG 11 TROUBLESHOOTING Fault Possible cause Troubleshooting User profiles The luminaire does not light Contact problem Switch on again All The luminaire does not light No mains voltage Check mains voltage, check all connections Electrician The luminaire does not light LED module defective Contact manufacturer service By manufacturer service only 12 TECHNICAL DATA Electrical data: Rated input voltage 100 - 240VAC Frequency range 50/60 Hz Power consumption 12-15W (14-20VA) Input current 0.08-0.14A Power factor 0.75-0.86 Power supply secondary side 24VDC Photometric values: Central illuminance Ec at 0.5m (1.64 feet) distance 60‘000 lx * Light field diameter d10 at 0.5m (1.64 feet) distance Ø = 21cm (8.3”) * Light field diameter d50 at 0.5m (1.64 feet) distance Ø = 12 cm (4.7”) * Colour temperature 4500K / 3500K * Colour rendering index Ra >95 Colour rendering index R9 >90 Total irradiance Ee at maximum intensity <230 W/m Ratio irradiance Ee to illuminance Ec 3.83 mW/m /lx 2 2 * -10% / +20% tolerace Ambient conditions for transport, storage and operation: Ambient temperature (storage and transport) -20°C to +70°C (-4°F to +158°F) Ambient temperature (operation) +10°C to +35°C (+50°F to +95°F) Relative humidity (non-condensing) (storage and transport) max. 90% Relative humidity (non-condensing) (operation) max. 75% Weight: Luminaire head 0.6kg (1.3 lb) CLED23 T1C 9kg (19.8 lb) CLED23 TXPPS 2kg (4.4 lb) Mode of operation: Mode of operation 10 Continuous operation ENG Classification: CLED23 Protection class I (C-version Protection class II (PPS-version) Degree of protection according to IEC 60529 Luminaire head (only in horizontal position) IP 20 IP 43 Classification according to directive 93/42/EWG – annex IX (medical device class) U.S. FDA Device Class Class I Class I Electrical safety test and EMC according to: IEC 60601-1 IEC 60601-2-41 IEC 60601-1-2 GMDN-Code 12276 Service life of the light source: Service life LED 30‘000h (L70/B50) 11 ENG 13 ELECTROMAGNETIC COMPATIBILITY (EMC) Electromagnetic emission guidelines The medical device is intended for operation in an electromagnetic environment such as the one specified below. The user must ensure that it is operated in such an environment. Emissions In accordance Electromagnetic environment High-frequency emissions Group 1 The medical device uses HF energy exclusively for its internal function. This (CISPR 11) means that its HF emissions are very low, and it is unlikely that adjacent electronic devices will receive interference. High-frequency emissions Class B The medical device is intended for use in all facilities, including residential (CISPR 11) buildings and facilities that are directly connected (without a transformer) to the same low voltage network as residential buildings. Emissions from harmonics Class A (IEC 61000-3-2) Emissions from voltage Compliance fluctuations/flicker (IEC 61000-3-3) Electromagnetic interference resistance guidelines The medical device is intended for operation in an electromagnetic environment such as the one specified below. The user must ensure that it is operated in such an environment. Interference resistance to IEC 60601-1-2 testing Conformity level of the Electromagnetic environment level medical device Electrostatic discharge (ESD) Contact discharge: ± 6 kV ± 6 kV Floors made of timber, concrete or ceramics tiles (IEC 61000-4-2) Air discharge: ± 8 kV ± 8 kV are preferred. Where synthetic floor covering is used the relative humidity should be at least 30%. Fast transients/ Power supply cables: ± 2 ± 2 kV The quality of the mains power supply should electrical disturbance kV match that of a typical business or hospital variables/ Longer input and Not applicable environment. bursts (IEC 61000-4-4) output cables: ± 1 kV Surge voltages/surges ±1 kV phase-to-phase ±2 kV The quality of the mains power supply should (IEC 61000-4-5) voltage match that of a typical business or hospital ±2 kV phase-to-earth ±1 kV environment. voltage Magnetic field in the power 3 A/m 3 A/m In proximity of this medical device, do not operate supply frequency (50/60 Hz) devices with unusually strong network-frequency (IEC 61000-4-8) magnetic fields (transformer stations etc.) . Voltage dips and short Cut >95 %, 0.5 periods Cut >95 %, 0.5 periods The supply voltage quality should be that of a interruptions Cut 60 %, 5 periods Cut 60 %, 5 periods typical business or hospital environment. If the to the power voltage Cut 30 %, 25 periods Cut 30 %, 25 periods user requires continued function during any (IEC 61000-4-11) Cut >95 %, 5 seconds Cut >95 %, 5 seconds interruption of the energy supply system, we recommend that the medical device be powered by an uninterrupted power supply or a battery. Radiated HF disturbance 3 V/m 3 V/m Recommended minimum distance of portable and variable (IEC 61000-4-3) 80 MHz - 2.5 GHz mobile radio devices of PEIRP radiated power to the medical device, including its cables: d = 1.17√P Conducted HF disturbance 3 Vrms-value 3 Vrms-value Recommended minimum distance of portable and values (IEC 61000-4-6) 150 kHz - 80 MHz: mobile radio devices of PEIRP radiated power to the medical device, including its cables: 80MHz - 800MHz: d = 1.17√P 800MHz - 2.5GHz: d = 2.33√P d = recommended safe distance [m], P = Rated Power of the sender [ W ]. Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey should be less than the compliance level in each frequency range. Interference may occur in the vicinity of equipment marked with: Recommended safe distances from portable and mobile HF communications equipment Rated Power of the sender [ W ] 150 kHz - 800 MHz 800 MHz - 2.5 GHz 0.01 0.12 m (0.39 ft) 0.23 m (0.75 ft) 0.1 0.37 m (1.21 ft) 0.74 m (2.43 ft) 1 1.17 m (3.84 ft) 2.33 m (7.64 ft) 10 3.7 m (12.14 ft) 7.37 m (24.18 ft) 50 8.27 m (27.13 ft) 16.48 m (54.07 ft) 100 11.7 m (38.39 ft) 23.3 m (76.44 ft) 12 These installation and operating instructions are for customer information only and will only be updated or replace upon request by the customer http://www.brandon-medical.com e-mail: [email protected] © Brandon Medical Co. Ltd. • D80.020.000 • 04.2014 • Index: 1.2 • Subject to modification • printed in Switzerland Brandon Medical Co. Ltd. Elmfield Road, Morley Leeds LS27 0EL Telephone: +44 (0) 113 27 77393 Fax: +44 (0) 113 27 28844
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement