ICM CONTROLS ICM870 Soft Starter Built-in Start Capacitor Installation Guide

Add to My manuals
1 Pages

ICM Controls ICM870 is a soft-start motor controller designed for Marine, Recreational Vehicle, and commercial applications. It reduces starting current and monitors system health, voltage, current, compressor startup, and self-integrity. Upon a fault condition, the ICM870 initiates a 3-minute anti-short cycle routine while providing diagnostic fault information via an LED indicator.

advertisement

ICM CONTROLS ICM870 Soft Starter Built-in Start Capacitor Installation Guide | Manualzz

9A / 16A

IMPORTANT SAFETY INFORMATION

HIGH VOLTAGE WARNING – Always turn off power at the main service panel before installing.

CAUTION: The ICM870 must be mounted in an area where it will not be exposed to water or the elements. Exposure of the ICM870 soft start to water can cause failure of the control and is a risk for fire or other electrical safety hazards.

Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes, 240 V maximum when protected by a circuit breaker having an interrupting rating not less than 40 rms symmetrical amperes, 240 volts maximum.

Installation of any ICM870 soft start must be done by a certified HVAC technician or licensed electrician. All installations are to be done in accordance with local, state, and national electrical codes.

ICM870 Comparable Amperage Crosses

The ICM870-9A and 16A models cross to the comparable amperage models from the following manufacturer’s

Micro-Air (Easy Start)

Dometic (Smart Start)

Network RV (Soft Start)

Hyper Engineering (Sure Start)

FEATURES

Starting current reduction and self-learning algorithm

Built-in start capacitor

Over-current protection

Over/under voltage monitoring

Diagnostic indicators

Sealed enclosure

INSTALLATION

Step #1 a) Disconnect factory installed compressor run wire from the run capacitor (c/common/L2) terminal b) In its place, connect the ICM870 RED WIRE > to the run capacitor (c/common/L2) terminal

Step #2 Connect the ICM870 BROWN WIRE > to the factory installed compressor run wire previously disconnected in step #1a

If there is a Start Capacitor and or PTCR already in place, additional steps will be required to disconnect them.

Step #3 Connect the ICM870 BLUE WIRE > to the run capacitor (herm/ hermetic/start) terminal

Step #4 Splice the ICM870 BLACK WIRE > with the factory install compressor Overload Switch wire (OL/L1)

LED INDICATORS

Start = Green Run = Green Fault = Red (flashing)

Fault Code

1

2

3

4

5

FAULT CODES

Fault Condition

High or low voltage

Compressor not Sensed or open fuse

High current

Compressor start error

Invalid operating frequency

SPECIFICATIONS

Semiconductor soft-start motor controller, Form 2, bypassed controller

• SCCR: 5kA • Ue = 240 VAC • Ui = 240 VAC • Uimp = 4kv

• FCC Class B • Pollution degree 3 • UL File E340301 • UL 60947-4-2 and IEC 60947-4-2

Input (L1, L2) – 100-240 VAC 50/60Hz

Over voltage limits: 115 VAC nominal = 140 VAC

240 VAC nominal = 250 VAC

Under voltage limits: 115 VAC nominal = 95 VAC, 240 VAC nominal =195 VAC

Outputs: Compressor

Solid state/relay

Current: Max. nominal = 9 FLA for ICM870-9A, 16 FLA for ICM870-16A

Over current limits: ICM870-9A = 11.25A, ICM870-16A = 20A

Environmental:

Ambient temperature:

40°C @ 16 FLA, 8 h duty

50°C @ 16 FLA, Temporary duty F = 30% (3 mins ON and 7 mins OFF)

S = 6 (6 cycles per hour)

Storage temperature: -40°F to 149°F (-40°C to 65°C)

Humidity: 0-95% non-condensing

Enclosure: IP65

Dimensions: ICM870-9A/16A (7.60” x 3.20” x 2.10”)

Screw Hole Center Points: 7.36” x 2.90”

APPLICATION

The ICM870 is intended for Marine, Recreational Vehicle, and commercial applications. The ICM870 integrates compressor in-rush current over startup time, thus reducing peak current demand on a power supply source

(generator or other). The ICM870 will monitor system health including voltage, current, compressor startup and self integrity. Upon a fault condition, the ICM870 will halt operation and initiate a 3 minute anti-short cycle routine while providing diagnostic fault information by means of an

LED indicator.

Softstart

Legend:

S = Start

C = Common

H = Hermetic

R = Run

OL = Overload Switch

ICM Technical Support: 800.365.5525

WIRING DIAGRAM

L1 L2

OL

C

R S

Compressor

H

Run

Cap

C

LIAF288-1

advertisement