MC
E Series
Lightweight Touring Power Amplifiers
E45
Operating Instructions
MC www.mc2-audio.co.uk
Tel. +44 (0)1404 44633 Fax. +44(0)1404 44660
Honiton | Devon | England | EX14 1YG
Page 2 E Series – E45 Operating Instructions
E Series – E45 Operating Instructions
Page 3
CONTENTS
DECLARATION OF CONFORMITY ........................................................................ 4
THANKS ............................................................................................................... 5
INTRODUCTION ................................................................................................... 5
IMPORTANT SAFETY INSTRUCTIONS ................................................................ 6
INSTRUCTIONS DE SECURITE IMPORTANTES ...................................................7
Installing Your Amplifier: Electrical Considerations ......................................... 8
Installing Your Amplifier: Mechanical Considerations ...................................... 9
Installing Your Amplifier: RF Emissions ........................................................... 9
About Your Amplifier: Dynamic Amplifier Performance Measurements ........ 10
Connecting To Your Amplifier: Inputs ................................................................ 11
Connecting To Your Amplifier: Speaker Outputs .............................................. 12
Connecting To Your Amplifier: Bridged (Mono) Operation ............................... 13
Operating Your Amplifier: Front Panel Controls and Indicators ...................... 14
Operating Your Amplifier: Notes and Switching On ......................................... 15
Operating Your Amplifier: Rear Panel Sockets and Switches ......................... 16
Looking After Your Amplifier: Maintenance ..................................................... 17
Looking After Your Amplifier: Warranty ........................................................... 17
Changing the Gain of Your Amplifier: Internal Adjustments! ........................... 18
Performance Of Your Amplifier: Specifications ............................................... 19
Page 4 E Series – E45 Operating Instructions
DECLARATION OF CONFORMITY
We, the manufacturer:
MC
2
Audio,
Units 6-8 Kingsgate
Heathpark Industrial Estate
Honiton, Devon
England
EX14 1YG
acknowledge our responsibility that the following products:
Kind of equipment: Audio amplifier
Commodity Code: 8518408990
Type Designation:
are manufactured:
T500, T1000, T1500, T2000, T3500, T4-250
Ti500, Ti1000, Ti1500, Ti2000, Ti3500, Ti4-250
E15, E25, E45, E90, E100, E475
S800, S1400 and all OEM variants of these models
in accordance with EMC Directive 2004/108/EC, in compliance with the following norm(s) or document(s):
Technical Regulations: EN55103-1:1996, EN55103-2:1996
and in accordance with the Low Voltage Directive 2006/95/EC, in compliance with the following norm(s) or document(s):
Technical Regulations: EN/IEC60065:2002 7 th
Edition
Signed: ……………………………………………………………………
Name:
Position:
Date:
Alex Cooper
Research and Development Manager
January 2012
E Series – E45 Operating Instructions
Page 5
THANKS
Thank you for choosing an E Series amplifier for your application.
Please spend a little time reading through this manual, so that you obtain the best possible performance from the unit and become familiar with its operating requirements.
All MC
2
products are carefully designed and engineered for cutting-edge performance and world-class reliability. If you would like further information about this or any other MC
2 product, please contact us.
We wish you many years of service from this amplifier and look forward to hearing from you in the near future.
INTRODUCTION
This lightweight, modified class H amplifier has been designed to the same high standards of reliability and sound quality that our customers have come to expect of all MC
2
audio products.
As with all E Series amplifiers, the E45 will deliver its rated power over the entire audio bandwidth, and a resonant switchmode power supply with a large reservoir gives extremely high peak power without any “bass sag”.
Optical limiters keep mains input and output currents within a safe operating area at all times, whilst maintaining transparent sonic performance.
Power Reduction Circuitry (PRC) controls on the rear panel, linked to the limiter thresholds, allow each channel to be independently set so that different speakers can be safely connected to each channel.
Running cool in even the most difficult conditions, the E45 can deliver over 2500W into 4 ohms with both channels driven, and an impressive 8400W (4R) bridged, with outstanding distortion and noise figures right up to maximum output.
The amplifier, of course, includes full DC, VHF, thermal and short circuit protection to ensure continuous trouble-free service.
Page 6 E Series – E45 Operating Instructions
IMPORTANT SAFETY INSTRUCTIONS
CAUTION: RISK OF ELECTRIC SHOCK.
DO NOT OPEN
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence if uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
WARNING: Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
WARNING: To prevent injury, this apparatus must be securely attached to the rack in accordance with the installation instructions.
Read these instructions.
Keep these instructions.
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged in any way, such as if the power-supply cord or
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with a dry cloth. plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.
Do not block any ventilation openings, install in accordance with the manufacturer’s instructions.
Do not install near any heat sources, such as radiators, heat registers, stoves or other apparatus
(including amplifiers) that produce heat.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles and the pint where they exit from the apparatus.
The mains circuit breaker shall remain readily accessible.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, tripod, bracket or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from a tip over.
Disconnect this apparatus during lightning storms or when unused for a long period of time.
To completely disconnect this equipment from the AC mains, disconnect the power cord from the mains circuit breaker.
Where the amplifier is mounted in a rack and permanently connected to the mains, then the rack should be installed with a readily accessible connector or an ALL POLE circuit breaker with 3mm breaking distances.
This unit is fitted with a 3-wire power cord. For safety reasons, THE EARTH LEAD SHOULD NOT BE
DISCONNECTED IN ANY CIRCUMSTANCE.
The cooling fans suck cool air in through the front and blow hot air out at the rear of the unit through the ventilating grills. The front and rear of the amplifier should have free exposure to the air (i.e. in a rack leave the front and rear doors off), with 2cm air gap at the sides and top. IF AIR IS NOT ALLOWED TO ESCAPE
FROM THE REAR, OVER-HEATING WILL OCCUR. Take care when mounting other equipment in the same rack.
The mains switch on the amplifiers only switches one pole of the mains supply, therefore for units with a detachable cord to be fully disconnected from the mains, the mains disconnect device (ie mains plug or mains coupler) should remain readily operable. For units with a fixed mains lead the external all pole circuit breaker with 3mm breaking distances is the disconnect device and therefore the installation of the amplifier shall be carried out in accordance with all the applicable installation rules.
E Series – E45 Operating Instructions
Page 7
INSTRUCTIONS DE SECURITE IMPORTANTES
ATTENTION: RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
Le symbole représentant un éclair fléché dans un triangle équilatéral a pour but d’alerter l’utilisateur de la présence d’une “tension dangeruese” non isolée à
Le point d’exclamation dans un triangle
équilatéral a pour but d’alerter l’untilisateur de la présence d’instructions importantes concernant le l’intérieur du boitier, pouvant être d’une force suffisante pour constituer un risqué d’électrocution. fonctionnement et la maintenance, dans la documentation qui accompagne l’appariel.
ATTENTION: Appareils de construction de CLASSE I doit être raccordé au réseau électrique via une prise de courant reliée à la terre.
ATTENTION: Pour éviter toute blessure, cet appareil doit être solidement fixé à la torture, conformément aux instructions d'installation.
Lisez ces instructions.
Gardez ces instructions. l'appareil a été exposé pour pleuvoir ou l'humidité, n'opère pas normalement, ou a été baissé.
Faites attention à tous les avertissements.
Suivez toutes les instructions.
N'utilisez pas cet appareil près de l'eau.
Faites le ménage seulement avec un tissu sec.
N'exposez pas cet équipement au fait de tomber goutte
à goutte ou au fait d'éclabousser et garantissez qu'aucun objet rempli des liquides, comme les vases, n'est placé sur l'équipement.
Pour complètement débrancher cet équipement de la conduite principale de courant alternatif, débranchez la corde de pouvoir du disjoncteur de conduite principale.
Ne bloquez pas d'ouvertures de ventilation, installez conformément aux instructions du fabricant.
N'installez près d'aucunes sources de chaleur, comme les radiateurs, les registres de chaleur, les cuisinières ou d'autre appareil (en incluant des amplificateurs) qui produisent la chaleur.
Protégez la corde de pouvoir d'être marché sur ou pincé particulièrement aux prises de courant, les réceptacles d'avantage et la pinte où ils sortent de l'appareil.
Le disjoncteur de conduite principale restera sans
Où l'amplificateur est monté dans un égouttoir et en permanence raccordé à la conduite principale, alors l'égouttoir devrait être installé avec un connecteur sans hésiter accessible ou TOUT le disjoncteur de PÔLE avec
3 millimètres cassant des distances.
Cette unité est correspondue avec une corde de pouvoir de 3 fils. Pour les raisons de sécurité, l'AVANCE DE
TERRE NE DEVRAIT ÊTRE DÉBRANCHÉE DANS
AUCUNE CIRCONSTANCE.
Les ventilateurs engloutissent l'air frais par le front et soufflent l'air chaud à l'arrière de l'unité par les grils aérants. Le front et l'arrière de l'amplificateur devraient hésiter accessible.
Utilisez seulement des attachements/accessoires spécifiés par le fabricant.
Utilisez seulement avec le chariot, le trépied, la parenthèse ou la table spécifiée par le fabricant, ou vendu avec l'appareil. Quand un chariot est utilisé, utilisez la prudence en déplaçant la combinaison de chariot/appareil pour éviter la blessure d'un bout.
Débranchez cet appareil pendant les tempêtes de foudre ou quand neuf pendant un long terme de temps.
Renvoyez tout l'entretien au personnel de service qualifié. L'entretien est exigé quand l'appareil a été nui de toute façon, comme si la corde de pouvoir provision ou la prise de courant sont nuis, le liquide a
été déversé ou les objets sont tombés dans l'appareil, avoir l'exposition libre à l'air (c'est-à-dire dans un
égouttoir omettent les portes de devant et arrière), avec le trou aérien de 2 centimètres aux côtés et au haut. Si on NE PERMET PAS QUE D'AIR S'ÉCHAPPE DE
L'ARRIÈRE, LE FAIT DE SURCHAUFFER SE PRODUIRA.
Faites attention en montant d'autre équipement dans le même égouttoir.
L'interrupteur principal sur les amplificateurs ne coupe qu'un pôle de l'alimentation secteur. le cordon IEC permettra de déconnecter l'appareil de l'alimentation secteur, pour cette raison l'accès à ces fiches (fiche mâle ou femelle) doit être facilités.
Pour les appareils avec un câble d'alimentation fixe sans fiche secteur, le dispositif de coupure omnipolaire ayant une distance d'ouverture de contact d'au moins
3mm, sera le dispositif permettant la déconnexion complète de l'appareil.
Pour cette raison l'installation et le raccordement de l'amplificateur devra ce faire conformément au réglementation en vigueur.
Page 8 E Series – E45 Operating Instructions
Installing Your Amplifier: Electrical Considerations
The amplifier has been manufactured to comply with your local power supply requirements, but before connecting the unit to the supply, ensure that the voltage (printed on the rear panel) is correct.
The amplifier is fitted with an adjustable 100/120V to 220/240V tapped transformer according to customer requirements. Please note that adjustment of mains operating voltage requires other component changes and must be undertaken by qualified service personnel only.
Make sure power outlets conform to the power requirements listed on the back of the unit.
Damage caused by connecting to improper AC voltage is not covered by the warranty.
SAFETY WARNING
Where a MAINS plug or appliance coupler is used as the disconnect device, it should remain readily operable.
Where the amplifier is mounted in a rack and permanently connected to the mains, then the rack should be installed with a readily accessible connector or an ALL POLE circuit breaker with 3mm breaking distances.
This unit is fitted with a 3-wire power cord.
For safety reasons,
THE EARTH LEAD SHOULD NOT BE DISCONNECTED IN ANY CIRCUMSTANCE
.
If ground loops are encountered consult the section on connecting your amplifier on page 11.
The wiring colours are:
230V AREAS: EARTH = GREEN AND YELLOW
NEUTRAL = BLUE
LIVE = BROWN
120V AREAS: EARTH = GREEN
NEUTRAL = WHITE
LIVE = BLACK
DO NOT USE THE UNIT IF THE ELECTRICAL POWER CORD IS FRAYED OR BROKEN. The power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs and the point where they exit from the appliance.
ALWAYS OPERATE THE UNIT WITH THE AC GROUND WIRE CONNECTED TO THE ELECTRICAL
SYSTEM GROUND. Precautions should be taken so that the means of grounding of a piece of equipment is not defeated.
DO NOT REMOVE THE LID. Removing the lid will expose you to potentially dangerous voltages. There are no user serviceable parts inside.
ESD strikes to the unit’s front panel that are in excess of 4000 volts may cause disturbance to the status LEDs on the unit. This will not affect audio performance and will be corrected on the next power up cycle.
E Series – E45 Operating Instructions
Page 9
Installing Your Amplifier: Mechanical Considerations
To ensure that this equipment performs to specification, it should be mounted in a suitable rack or enclosure as described below. Like all high power amplifiers, it should be kept away from other equipment which is sensitive to magnetic fields. Also, this amplifier may suffer a substantial reduction in performance if it is subjected to, or mounted close to equipment which radiates high RF fields.
Warning: To prevent injury, this apparatus must be securely attached to the rack in accordance with the installation instructions
When mounting the amplifier in a rack or enclosure:
Be aware that…
THE FRONT PANEL IS NOT CAPABLE OF SUPPORTING THE UNIT ON ITS OWN.
Make sure that the rear of the unit is adequately supported. The brackets which are supplied fit standard 19 inch (483mm) rack mounting systems.
ENSURE THERE IS ADEQUATE VENTILATION.
The cooling fans suck cool air in through the front and blow hot air out at the rear of the unit through the ventilating grills. The front and rear of the amplifier should have free exposure to the air (i.e. in a rack leave the front & rear doors off), with 2cm air gap at the sides.
IF AIR IS NOT ALLOWED TO ESCAPE FROM THE REAR, OVER-HEATING WILL OCCUR.
Take care when mounting other equipment in the same rack.
Make sure that the rack unit has a separate earth connection (technical earth).
Please also see the notes regarding maintenance on page 17.
Installing Your Amplifier: RF Emissions
The high frequency resonant converters in the E Series amplifiers have been designed to have very low radio frequency (RF) emissions; however even these low level emissions can cause interference with other equipment.
In order for this to be minimised, the amplifier should be mounted in a metal rack enclosure, which should have a separate (technical) Earth. Alternatively a separate earth should be attached to the amplifier at the rear rack mounting bracket.
Page 10 E Series – E45 Operating Instructions
About Your Amplifier: Dynamic Amplifier Performance Measurements
The E90 is the very latest example of a ‘dynamic amplifier’. This new ‘breed’ of power amplifiers provide very high peak power levels in a much smaller, and lighter, package than previously possible with conventional amplifiers.
They are designed specifically for today’s high power audio installations, which use multiple speakers with electronic crossovers or speaker controllers. These systems can handle very high transient signals that far exceed their RMS power rating. The E Series amplifiers have been designed to match this requirement and can deliver huge levels of power for short durations.
In order to protect themselves and the loudspeakers that they are driving, continuous signals such as sine waves, are automatically detected and reduced (ramped down) to a safe level.
When trying to measure the power output however, continuous signals will give totally incorrect results. A dynamic signal, such as a tone burst, should be used and the levels measured by monitoring the waveform on an oscilloscope. The power envelope can then be accurately measured.
Our power output figures are measured using signals with known Crest Factors and are quoted at the rear of this manual and on our website.
Please refer to the Technical Support area of our website for further information.
E Series – E45 Operating Instructions
Page 11
Connecting To Your Amplifier: Inputs
The inputs are made via 3-pin XLR connectors, which are electronically balanced and should be connected via a high grade twin core screened cable, as follows:
PIN1: Screen (see note)
PIN2: Hot (signal +)
PIN3: Cold (signal -)
The amplifier is designed to operate with fully balanced equipment and ground loops or loss of performance may be experienced if connected to unbalanced sources. If it is unavoidable however, the following wiring should be used. The cable should still be twin core plus screen.
PIN1: Screen - connected to the chassis of the unbalanced equipment - or left disconnected at the unbalanced end.
PIN2: Hot (signal +)
PIN3: Cold (ground 0V)
NOTE: This amplifier is wired to the latest industry recommendations. PIN1 is connected directly to the chassis/mains earth. If ground loops (mains hum) are encountered remove the screen connection from the other end of the cable and leave it open circuit. If problems persist, consult your dealer/supplier.
DO NOT TAMPER WITH OR ALTER ANY GROUND (EARTH) CONNECTIONS INSIDE THE
AMPLIFIER.
Page 12 E Series – E45 Operating Instructions
Connecting To Your Amplifier: Speaker Outputs
The speaker outputs are via Neutrik Speakon connectors. 2 pole (NL2FC) connectors can be used, but 4 pole (NL4FC) connectors should be used to connect to the bridge/stereo 4 pole output socket.
Channel A/B outputs:
Pin 1+: Hot
Pin 1-: Cold
Bridge/Stereo output:
Pin 1+: Ch. A Hot
Pin 1-: Ch. A Cold
Pin 2+: Ch. B Hot
Pin 2-: Ch. B Cold
There must be no shared connections between channels.
Negative output terminals must not be joined together as they are not both at ground potential. Connecting them together will damage the amplifier and void the warranty!
As the currents involved are very high, and to ensure best performance, the speaker cables should be kept as short as possible and conform to the following minimum requirements:
E45, 20A into 4 Ohm speaker loads
When operating the amplifier into loads of less than 4 Ohms, be aware that the current capacity of the speaker cables will need to be increased above the values quoted here.
Do not connect the inputs/outputs to any other voltage source such as a battery, mains source or power supply, regardless of whether the amplifier is turned on or off.
Do not run the output of any amplifier channel back into another channel’s input and do not parallel or series-connect an amplifier output with any other amplifier output.
For details of bridged operation please see overleaf — there are important differences in connections and cable specifications!
E Series – E45 Operating Instructions
Page 13
Connecting To Your Amplifier: Bridged (Mono) Operation
Use the centre Speakon connector marked Bridge/Stereo, and depress the button between the XLR connectors to the “Channel Link [A]” position.
Connect the speaker as follows: Pin 1-: Cold (A)
Pin 2+: Hot (B)
When operating in bridged more, the minimum impedances are doubled.
The minimum load in bridged mode is 4 Ohms.
Page 14 E Series – E45 Operating Instructions
Operating Your Amplifier: Front Panel Controls and Indicators
1: Power Switch: This single pole switch turns the amplifier fully off (but does NOT isolate it from the mains supply).
2: Power LED: This indicates when the amplifier is active. This does NOT indicate the presence of a mains supply when the power switch is OFF.
3: Signal Meter and OCM indicators: These LED bar graphs show instantaneous level on each channel to indicate proximity to the limiter threshold. Note that if the PRC system is in operation on any channel, this will affect the readout shown on the respective meter.
The red LED in the meter will illuminate when the limiter threshold has been reached and limiting is occurring. The output current monitor (OCM) may activate to limit the output current of the amplifier channel - this can occur even if the amplifier has not reached clipping point.
The OCM indicator can operate independently of the bar graph meter. Typical conditions that may trigger the OCM circuitry would be very low load impedance, or high subsonic or VHF levels.
4: Attenuation Controls: These are analogue controls allowing precise level settings. Note that in linked mode some controls may be inactive.
5: Link LED: This indicates if the channels are linked together. If this is illuminated, the attenuation control and meter of channel B not function as both channels are being fed from channel A’s control. The link switch is on the rear panel — see page 16 for details.
6: PRC LED: This illuminates if the Power Reduction Control has been enabled on the respective channel. PRC switches are on the rear panel — see page 16 for details.
7: A/P (Auto Protect) LED: If a condition exists, either internally or externally, that could cause damage to either the amplifier or the speakers, the protection circuit will disengage the outputs and the A/P LED will illuminate. The amplifier will continue to be monitored and depending on the type of fault, will either reset after the fault has cleared or require manual resetting by switching off at the mains switch and then on again after a few seconds.
E Series – E45 Operating Instructions
Page 15
Typical conditions that could cause the protection to be triggered include very high frequency or subsonic input signals, DC in the inputs, short-circuited outputs, or internal high temperatures.
The protection circuit can affect both channels or an individual channel, depending on the type of fault. This is indicated by the combination of A/P LED and OCM LED illuminating.
Temperature related faults will reset if the unit has cooled sufficiently.
Output short circuits will require manual reset after clearing the fault. A/P will illuminate together with the OCM LED on the shorted channel.
Operating Your Amplifier: Notes and Switching On
Read all documentation before operating your equipment and retain all documentation for future reference.
Do not spill water or other liquids into or on the unit and do not operate the unit while standing in liquid.
Do not block fan intake or rear ventilation outlets or operate the unit in an environment that could impede the free flow of air around the unit.
If the unit is used in an extremely dusty or smoky environment, it should be cleaned of any collected debris at regular intervals. Please also see the notes regarding maintenance on page 17.
It is important that the power output of your amplifier is matched to the power handling capacity of your loudspeaker. If not, damage to the loudspeaker could occur.
Switching On…
At ‘switch-on’ the protection circuit will initially activate whilst the circuits stabilise, indicated by the red A/P LED illuminating, in addition to various other LEDs. After a few seconds the red
A/P LED will extinguish indicating a satisfactory working condition.
Other LEDs may remain illuminated depending upon rear panel switch settings and input connections. If the A/P LED does not extinguish after 5 seconds the unit may be faulty or some external connections may be incorrect or inappropriate. If this occurs you should power down the unit and remove all external connections (except for the mains power supply) and repeat the power up sequence. If the problem persists please contact us — details on page 17.
SERIAL NO.
Page 16 E Series – E45 Operating Instructions
Operating Your Amplifier: Rear Panel Sockets and Switches
4 5 6
3
Stereo
Channel
Link [A]
1: GND
2: Sig+
3: Sig-
S1 S2 P.R.C.
P.R.C.
Power
Reduction
Control
S1
0dB
-2dB
-4dB
-6dB
S2
CHANNEL B
OUT
DESIGNED AND
MANUFACTURED
IN ENGLAND BY
MC
2
BRIDGE/STEREO
OUT
CHANNEL A
OUT
Class 2 Wiring on Outputs
Channel A/B Outputs
1+: HOT
1-: COLD
Bridge/Stereo Output
For Stereo Use
1+: Ch.A HOT, 1- Ch.A COLD
2+: Ch.B HOT, 2-, Ch.B COLD
For Bridge Use
2+: HOT, 1-: COLD
E-SERIES
AMPLIFICATION
2 1
1: Channel A output Speakon socket: Output is wired pins 1+: hot, 1-: cold.
Similarly channel B’s output Speakon socket uses two poles wired as above.
2: Bridge/Stereo output Speakon socket: Output of both channels are available on this centre socket. It is wired pins 1+: Ch. A hot, 1-: Ch. A cold, 2+: Ch. B hot, 2-: Ch. B cold. For details of how to connect a speaker in bridge mode, see page 13.
3: Link switch: Press this switch to link the input of the channel A to both channels. Once linked, only channel A’s attenuator and meter will function.
4: Link XLR Socket: This socket is wired in parallel with its respective input socket to allow the input signal to be linked out to further amplifiers. It is a passive connection so it will function even when the amplifier is switched off.
5: Input XLR sockets: Connect signal inputs to these sockets, wired pin 2 hot, 3 cold, 1 ground. For sensitivity and impedance of these inputs, please see the specifications on page
18.
6: PRC switches: Each channel of the amplifier may be power limited independently using these pairs of switches in three stages, offering 2, 4 and 6dB of Power Reduction Control.
P.R.C.
S1 S2
Power
Reduction
Control
0dB
-2dB
-4dB
-6dB
The settings for these switches are on the rear panel for quick reference. Please refer to the power specifications on page 20 for more information on actual power reduction levels.
7: Fan outlet: The variable speed fans suck air in through the front vents and out through the back of the amplifier. Please see maintenance on page 17 for recommendations on how to clean this and the front foam sections.
7
WARNINGS
All vents on front and rear of unit must not be obstructed.
This unit must be earthed.
SHOCK
HAZARD
Do not remove covers.
To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
E Series – E45 Operating Instructions
Page 17
Looking After Your Amplifier: Maintenance
These maintenance instructions are for use by qualified personnel only. Before any routine maintenance, please ensure that your amplifier is disconnected from the mains supply!
The filter behind the air intake apertures on the front of your amplifier should be cleaned or replaced periodically, e.g. 3 -6 months. (Filters in amplifiers located in more 'dirty' atmospheres may require more frequent maintenance).
The filter should be 'dry' cleaned, using a vacuum cleaner preferably. Running the unit without a filter is not recommended. We recommend replacement of filters every 2-3 years, depending on usage. Replacement filter material is available directly from us.
If the fan vents on the rear of the amplifier develop a build-up of dust/debris on the finger guards, they can be cleaned with a dry paintbrush and a vacuum cleaner.
The casework of the amplifier may be cleaned with a lightly dampened cloth — do not use any solvents as they will damage the paint finish and could remove printing.
If you have any doubts about carrying out maintenance, please refer to a service engineer or contact your local dealer.
Looking After Your Amplifier: Warranty
Your amplifier is guaranteed for a period of five (5) years from the date of manufacture.
Please note that this does not apply to OEM versions of the amplifier — please consult your manufacturer for their warranty terms. We hope that it gives you many more years of reliable service than this, but should anything go wrong, please contact us to advise you about repairs or any spares you might require.
Please do not attempt to repair the amplifier yourself as doing so will invalidate the warranty.
Our contact details are:
MC
2
Audio,
Units 6-8 Kingsgate
Heathpark Industrial Estate
Honiton, Devon
England
EX14 1YG
Tel: +44(0)1404 44633
Fax: +44(0)1404 4466 email: [email protected]
for general enquiries
Our website is a great place to get started if you have any questions regarding the general use of your amplifier or need copies of this manual in digital form, or datasheets and photographs. The datasheets also contain architect’s and engineer’s specifications. www.mc2-audio.co.uk
Page 18 E Series – E45 Operating Instructions
Changing the Gain of Your Amplifier: Internal Adjustments!
These instructions are for use by qualified personnel only. Before any routine maintenance, please ensure that your amplifier is disconnected from the mains supply!
Gain/Sensitivity Settings
The voltage gain of the amplifier can be selected to be either +32dB (standard) or +26dB or a fixed sensitivity of +6dBu input level* to match system sensitivity as required. This is achieved by setting links on the input board internally.
After removing the lid and with the rear panel facing away from you, locate the input circuit board as shown below – it is attached to the input XLR connectors. Find the sets of links as marked by the arrows, and move them as shown to set the gain as required. Number 1 adjusts channel A’s gain, and number 2 adjusts channel B’s gain.
Link
1&2
32dB
Gain
(default)
Link
3&4
26dB
Gain
1 5
G a i n A
1 5
G a i n B
1
2
Fixed Sensitivity Setting:
+6dBu (1.5V)
Link
2&3
(36dB
Gain)
Remember, setting higher gain does not change the maximum available power but changes the level of signal input to achieve maximum power. In any case, provided that the input signal is less than 20dBu/7.7V, the built in limiter circuit will prevent distortion within the amplifier.
The gain should be set to match the signal level from the source — mixer, equaliser etc.
*Equivalent gain for the fixed sensitivity setting is 36dB.
E Series – E45 Operating Instructions
Performance Of Your Amplifier: Specifications
Main Specifications
Parameter (Units)
Output Power per channel [Crest Factor = 4.8] (Watts)
8 Ohms
4 Ohms
2 Ohms
Output Power per channel bridged [Crest Factor = 4.8] (Watts)
8 Ohms
4 Ohms
THD+N, 4 Ohms (%)
@1kHz, 1dB below max output power
<
@20Hz - 20kHz, 1dB below max output power
<
Gain Options (dB)
Sensitivity Options for max power (dBu)
Sensitivity Options for max power (Volts)
Frequency Response, +0/0.3dB (Hz)
Power Consumption, Nominal @ 240V, 4 Ohms (A)
Power Consumption, Nominal @ 120V, 4 Ohms (A)
Dimensions H x W x D (mm)
Amplifier
Boxed
Boxed Shipping — all except UK
Weight (kgs)
Amplifier
Boxed — shipping
Additional Specifications
Parameter (Units)
Input Impedance — Active Balanced (Ohms)
E45
20k
Input CMRR (dB)
SNR (dB)
Damping Factor, 1kHz, 8 ohms
Signal Limiters Present
Protection Present — Short Circuit / DC Output / Temperature
Mains In-rush Control Present
Output Power per channel, 8 Ohms (Watts)
>
60
106
>
400
Sine Wave @ 1kHz
Continuous music [Crest Factor of 2.8 or 9dB]
Continuous music [Crest Factor of 4.8 or 14dB]
Continuous music [Crest Factor of 7.8 or 18dB]
Output Power per channel, 4 Ohms (Watts)
Sine Wave @ 1kHz
1350
2050
Continuous music [Crest Factor of 2.8 or 9dB]
Continuous music [Crest Factor of 4.8 or 14dB]
2400
2500
2700 Continuous music [Crest Factor of 7.8 or 18dB]
Output Power per channel, 2 Ohms (Watts)
Sine Wave @ 1kHz 3300
4100 Continuous music with Crest Factor of 2.8 [9dB]
Continuous music with Crest Factor of 4.8 [14dB]
Continuous music with Crest Factor of 7.8 [18dB]
4200
4300
Due to continuing product improvement the above specifications are subject to change.
Yes
Yes
Yes
1100
1200
1250
E45
1250
2500
4200
5000
8400
0.015
0.05
26 / 32 / 36
15.7 / 9.7 / 5.7
4.7 / 2.4 / 1.5
20 — 20000
4.5
9.0
88 x 482 x 428
230 x 580 x 560
250 x 610 x 600
11.4
13.4
Page 19
Page 20 E Series – E45 Operating Instructions
Performance Of Your Amplifier: Specifications
Power Consumption and Thermal Emissions — E45
Mains
(V)
Load
(R)
Current Draw
(A)
Thermal Emissions
(W)
No Sig’l Light Average Heavy No Sig’l Light
240 8
1.0 1.7 2.7 5.5 240 281
240 4
1.0 2.4 4.5 10.1 240 322
240 2
1.0 3.2 6.9 16.5 240 370
120 8
2.0 3.4 5.5 11.1 240 281
120 4
2.0 4.8 9.0 20.2 240 322
120 2
2.0 6.4 13.7 33.1 240 370
No Sig’l = Quiescent, Light = Crest Factor of 7.8(18dB),
Average = Crest Factor of 4.8(14dB), Heavy = Crest Factor of 2.8(9dB)
For details of measurement methods please refer to the Technical Support area of our website.
PRC Settings and Maximum Output
Average Heavy
344
447
589
244
447
589
510
780
1163
510
780
1163
Power Reduction Control Setting
Maximum Power into 8 ohms (W)
-2dB PRC
Per Channel
1250
790
Bridged Pair
5000
3150
-4dB PRC 500 1990
-6dB PRC
Maximum Power into 4 ohms (W)
320
2500
1260
8400
-2dB PRC
-4dB PRC
-6dB PRC
1600
1000
630
5300
3300
2100
Maximum Power into 2 ohms (W)
-2dB PRC
-4dB PRC
4200
2700
1700
N/A
N/A
N/A
-6dB PRC
1050 N/A
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 DECLARATION OF CONFORMITY
- 5 THANKS
- 5 INTRODUCTION
- 6 IMPORTANT SAFETY INSTRUCTIONS
- 7 INSTRUCTIONS DE SECURITE IMPORTANTES
- 8 Installing Your Amplifier: Electrical Considerations
- 9 Installing Your Amplifier: Mechanical Considerations
- 9 Installing Your Amplifier: RF Emissions
- 10 About Your Amplifier: Dynamic Amplifier Performance Measurements
- 11 Connecting To Your Amplifier: Inputs
- 12 Connecting To Your Amplifier: Speaker Outputs
- 13 Connecting To Your Amplifier: Bridged (Mono) Operation
- 14 Operating Your Amplifier: Front Panel Controls and Indicators
- 15 Operating Your Amplifier: Notes and Switching On
- 16 Operating Your Amplifier: Rear Panel Sockets and Switches
- 17 Looking After Your Amplifier: Maintenance
- 17 Looking After Your Amplifier: Warranty
- 18 Changing the Gain of Your Amplifier: Internal Adjustments!
- 19 Performance Of Your Amplifier: Specifications