C79000-G8976-C359-03
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION indicates that minor personal injury can result if proper precautions are not taken.
NOTICE indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
C79000-G8976-C359-03
Ⓟ 09/2015 Subject to change
Copyright © Siemens AG 2015.
All rights reserved
These operating instructions support you when installing and connecting up devices of the
SCALANCE XB-200 product group.
The configuration and the integration of the devices in a network are not described in these operating instructions.
These operating instructions apply to the following devices:
● SCALANCE XB208
● SCALANCE XB205-3 (SC)
● SCALANCE XB205-3LD (SC)
● SCALANCE XB205-3
● SCALANCE XB216
● SCALANCE XB213-3 (SC)
● SCALANCE XB213-3LD (SC)
● SCALANCE XB213-3
Unless mentioned otherwise, the descriptions in these operating instructions refer to all devices of the SCALANCE XB-200 product group named above in the section on validity.
There are two variants of each device, refer to the section "Product overview (Page 11)".
Classification
Product line
Product group
Device
Description
The product line includes all devices and variants of all product groups.
If information applies to all product groups within the product line, the term SCALANCE X-200 is used.
If information applies to all devices and variants of a product group, the term SCALANCE XB-200 is used.
If information relates to a specific device, the device name is used.
Terms used
SCALANCE X-200
SCALANCE XB-200 e.g. SCALANCE XB205-3
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
3
4
Introduction
You will find detailed information on configuring the devices in the following configuration manuals:
● SCALANCE XB-200 Web Based Management
● SCALANCE XB-200 Command Line Interface
You will find the configuration manuals here:
● on the data medium that ships with some products:
– Product CD / product DVD
– SIMATIC NET Manual Collection
● On the Internet pages of Siemens Industry Online Support.
In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial
Ethernet / PROFINET passive network components", you will find information on other
SIMATIC NET products that you can operate along with the devices of this product line in an
Industrial Ethernet network.
There, you will find among other things optical performance data of the communications partner that you require for the installation.
You will find the system manuals here:
● On the data medium that ships with some products:
– Product CD / product DVD
– SIMATIC NET Manual Collection
● On the Internet pages of Siemens Industry Online Support under the following entry IDs:
– 27069465 ( http://support.automation.siemens.com/WW/view/en/27069465 )
Industrial Ethernet / PROFINET Industrial Ethernet System Manual
– 84922825 ( http://support.automation.siemens.com/WW/view/en/84922825 )
Industrial Ethernet / PROFINET - Passive network components System Manual
You will find the SIMATIC NET manuals here:
● On the data medium that ships with some products:
– Product CD / product DVD
– SIMATIC NET Manual Collection
● On the Internet pages of Siemens Industry Online Support
( https://support.industry.siemens.com/cs/ww/en/ps/15247 ).
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Introduction
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary here:
● SIMATIC NET Manual Collection or product DVD
The DVD ships with certain SIMATIC NET products.
● On the Internet under the following address:
50305045 ( http://support.automation.siemens.com/WW/view/en/50305045 )
You will find the order numbers for the Siemens products of relevance here in the following catalogs:
● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI
● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog
ST 70
● Industry Mall - catalog and ordering system for automation and drive technology, Online catalog
( https://eb.automation.siemens.com/goos/WelcomePage.aspx?regionUrl=/en&language= en )
You can request the catalogs and additional information from your Siemens representative.
WARNING
Do not use any parts that show evidence of damage
If you use damaged parts, there is no guarantee that the device will function according to the specification.
•
•
If you use damaged parts, this can lead to the following problems:
•
Injury to persons
•
Loss of the approvals
Violation of the EMC regulations
Damage to the device and other components
Use only undamaged parts.
1.
Make sure that the package is complete.
2.
Check all the parts for transport damage.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
5
Introduction
Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity .
To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com
.
The following and possibly other names not identified by the registered trademark sign
® registered trademarks of Siemens AG:
are
SIMATIC NET, SCALANCE, C-PLUG, OLM
6
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
1
2
3
4
5
6
2.1
2.2
2.2.1
2.2.2
2.2.3
2.3
2.4
3.1
3.2
4.1
4.2
4.3
4.4
5.1
6.3
6.4
6.5
6.6
5.2
6.1
6.2
6.7
6.8
6.9
6.10
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
7
Table of contents
7
A
8
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Note the following safety notices. These relate to the entire working life of the device.
You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up".
1
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
DO NOT OPEN WHEN ENERGIZED.
Safety notices when using the device according to Hazardous Locations (HazLoc)
If you use the device under HazLoc conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion:
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
9
Safety notices
10
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
2
There are two variants of each device with different article numbers. The two variants differ only in their factory settings. All other properties are identical.
Device Description
SCALANCE XB208 8 x 10/100 Mbps RJ-45 ports
SCALANCE XB205-3 (SC) 5 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps SC ports, multimode fiberoptic cable
SCALANCE XB205-3LD
(SC)
5 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps SC ports, single mode fiber-optic cable
SCALANCE XB205-3 5 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps ST ports, multimode fiberoptic cable
SCALANCE XB216 16 x 10/100 Mbps RJ-45 ports
SCALANCE XB213-3 (SC) 13 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps SC ports, multimode fiberoptic cable
SCALANCE XB213-3LD
(SC)
SCALANCE XB213-3
13 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps SC ports, single mode fiber-optic cable
13 x 10/100 Mbps RJ-45 ports, 3 x
10/100 Mbps ST ports, multimode fiberoptic cable
Article number
(Ethernet/IP)
Article number
(PROFINET)
6GK5 208-0BA00-2TB2 6GK5 208-0BA00-2AB2
6GK5 205-3BD00-2TB2 6GK5 205-3BD00-2AB2
6GK5 205-3BF00-2TB2 6GK5 205-3BF00-2AB2
6GK5 205-3BB00-2TB2 6GK5 205-3BB00-2AB2
6GK5 216-0BA00-2TB2 6GK5 216-0BA00-2AB2
6GK5 213-3BD00-2TB2 6GK5 213-3BD00-2AB2
6GK5 213-3BF00-2TB2 6GK5 213-3BF00-2AB2
6GK5 213-3BB00-2TB2 6GK5 213-3BB00-2AB2
EtherNet/IP variants
● Industrial Ethernet protocol: EtherNet/IP
● Base bridge mode: 802.1Q VLAN Bridge
● Redundancy mechanism: RSTP
● Trust mode: Trust DSCP
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
11
Description of the device
2.1 Product overview
PROFINET variants
● Industrial Ethernet protocol: PROFINET
● Base bridge mode: 802.1D transparent bridge
● Redundancy mechanism: Ring redundancy
● Trust mode: Trust COS
The type designation of a SCALANCE XB-200 is made up of several parts that have the following meaning:
Interfaces of devices with optical connectors:
Interface
(SC)
LD (SC)
[-]
Property
10/100 Mbps SC port, multimode fiber-optic cable, up to 5 km
10/100 Mbps SC port, single mode fiber-optic cable, up to 26 km
10/100 Mbps ST port, multimode fiber-optic cable, up to 5 km
The following components are supplied with a SCALANCE XB-200:
● One device
● Two 3-terminal blocks for the power supply
● One product DVD with documentation and software
The following accessories are available for SCALANCE XB-200:
Cable
Component
Connecting cable (RJ-
11/RS-232)
Description
Preassembled, serial cable with RJ-11 and RS-232 plug,
Length: 3 m pack of 1
Article number
6GK5 980-3BB00-0AA5
12
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Description of the device
2.2 Device views
The following figure shows an overview of the components of the SCALANCE XB208.
①
②
③
④
⑤
Electrical ports with port LEDs
Power supply with connector for grounding
Serial interface
"RESET" button (rear)
Fault LED
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
13
Description of the device
2.2 Device views
The following figure shows an overview of the components of the SCALANCE XB205-3.
①
②
③
④
⑤
⑥
Optical ports with port LEDs
Power supply with connector for grounding
Serial interface
Electrical ports with port LEDs
"RESET" button (rear)
Fault LED
14
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Description of the device
2.2 Device views
The following figure shows an overview of the components of the SCALANCE XB213-3.
①
②
③
④
⑤
⑥
Optical ports with port LEDs
Power supply with connector for grounding
Serial interface
Electrical ports with port LEDs
"RESET" button (rear)
Fault LED
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
15
Description of the device
2.3 RESET button
The "RESET" button is located on the rear of the SCALANCE XB-200.
Figure 2-1 Position of the "RESET" button, for example on the SCALANCE XB213-3
Note
Damage to the button
The RESET button is a short-stroke button with only a slight pressure point. To operate the button, you only need a force 2.5 N (approx. 250 g).
To avoid damaging the button press it with little force. Hold the tool you are using, for example, with only two fingers.
Note
If you reset, all the changes you have made will be overwritten by factory defaults.
To reset the device to the factory defaults, follow the steps below:
1.
Press the "RESET" button with only slight force.
A screwdriver for example with following size is suitable:
– Blade thickness 0.8 - 1.8 mm
– Blade width 4.0 - 4.8 mm
2.
Hold down the button for approximately 12 seconds.
After 9 seconds, the fault LED "F" flashes for 3 seconds.
– If you release the button after approximately 12 seconds, the device is restarted and the factory settings are restored.
– If you release the button before the 12 seconds have elapsed, the reset is canceled.
16
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Description of the device
2.3 RESET button
Using the WBM and CLI, you can enable or disable the button function.
● SCALANCE XB-200 Web Based Management, section "Button"
● SCALANCE XB-200 Command Line Interface, section "Panel-Button"
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
17
Description of the device
2.4 LED display
The fault LED "F" indicates the incorrect functioning of the device.
LED color
-
Green
Red
LED status
Off
Lit
Lit
Meaning
The device is a turned off.
The device has not detected a problem.
The device has detected a problem.
The connected power supply is too low.
Using the WBM and CLI, you can set when the device signals an error and which errors should be signaled.
The port LEDs indicate the status of the ports.
RJ-45 ports
Each RJ-45 port has 2 integrated LEDs.
The upper green LED shows the status of the link.
LED color
Green
-
LED status
Lit
Off
Meaning link exists
No link exists
The lower yellow LED shows the status of data reception.
LED color
Yellow
-
LED status
Flashing
Off
Meaning
Receiving data at port
Not receiving data at port
SC/ST ports
There is an LED for each SC/ST port.
LED color
Green
-
LED status
Lit
Off
Meaning
Link exists, data reception at port
No link exists
18
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
3
When installing the device, keep to the safety notices listed below.
WARNING
If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than
50 °C.
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION
2 OR ZONE 2.
WARNING
The device may only be operated in an environment with pollution degree 1 or 2 (see IEC
60664-1).
WARNING
When used in hazardous environments corresponding to Class I, Division 2 or Class I,
Zone 2, the device must be installed in a cabinet or a suitable enclosure.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
19
Installation
3.1 Safety notices for installation
Safety notices for use according to ATEX and IECEx
If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion:
WARNING
To comply with EC Directive 94/9 (ATEX95) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN 60529.
WARNING
If the cable or conduit entry point exceeds 70 °C or the branching point of conductors exceeds 80 °C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 60 ℃ , only use cables with admitted maximum operating temperature of at least 80 ℃ .
CAUTION
Use only approved components
If you use components and accessories that are not approved for SIMATIC NET devices or their target systems, this may violate the requirements and regulations for safety and electromagnetic compatibility.
Only use components approved for the SIMATIC NET devices.
NOTICE
Warming and premature aging of the IE switch due to direct sunlight
Direct sunlight can heat up the device and can lead to premature aging of the IE switch and its cabling.
Provide suitable shade to protect the IE switch against direct sunlight.
Note
During installation and operation, keep to the installation guidelines and safety notices described in this document and in the system manuals "Industrial Ethernet / PROFINET
Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components".
You will find information on the system manuals in the section "Introduction (Page 3)", in
"Further documentation".
20
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Installation
3.2 Mounting on DIN rails
Figure 3-1 DIN rail mounting
To install the device on a 35 mm DIN rail complying with DIN EN 60715, follow the steps below:
1.
2.
Place the housing guide of the device on the top edge of the DIN rail
①
.
Press the device down against the DIN rail until the spring catch locks in place
②
.
3.
Fit the connectors for the power supply, see the section "Power supply (Page 25)".
4.
Insert the terminal blocks into the sockets on the device.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
21
Installation
3.2 Mounting on DIN rails
Figure 3-2 Removing from a DIN rail
To remove the device from a DIN rail, follow the steps below:
1.
2.
3.
Disconnect all connected cables.
Release the DIN rail locking mechanism by pressing down on the release button
①
.
Pull the lower part of the device away from the DIN rail
②
.
22
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
4
When connecting up the device, keep to the safety notices listed below.
WARNING
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a
Limited Power Source (LPS).
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals. The power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code
(r) (ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements.
NOTICE
Failure of the data traffic due to contamination of optical plug-in connections
Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network.
Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps.
Remove the protective caps only immediately before you use the plug-in connection.
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR
COMBUSTIBLE ATMOSPHERE IS PRESENT.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
23
Connecting up
4.1 Safety when connecting up
Safety notices when using the device according to Hazardous Locations (HazLoc)
If you use the device under HazLoc conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion:
WARNING
EXPLOSION HAZARD
DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE
NON-HAZARDOUS.
Safety notices for use according to ATEX and IECEx
If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion:
WARNING
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
WARNING
Safety notice for connecting with a LAN ID (Local Area Network)
A LAN or LAN segment with all the interconnected devices should be contained completely in a single low voltage power distribution in a building. The LAN is designed either for
“Environment A” according to IEEE802.3 or "Environment 0" according to IEC TR 62102.
Do not connect any electrical connectors directly to the telephone network (telephone network voltage) or a WAN (Wide Area Network).
24
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Connecting up
4.2 Power supply
WARNING
Incorrect power supply
Never operate the device with AC voltage or DC voltage higher than 32 V DC.
CAUTION
Damage to the device due to overvoltage
The connector of the external power supply is not protected against strong electromagnetic pulses that can, for example, result from lightning strikes or switching large loads.
One of the tests used to attest the immunity of devices of the SCALANCE CB-200 IE switches to electromagnetic interference is the "surge immunity test" according to
EN61000-4-5. This test requires overvoltage protection for the power supply lines. A suitable device is, for example, the Dehn Blitzductor BVT AVD 24, article number 918 422 or a comparable protective element.
Manufacturer: DEHN+SOEHNE GmbH+Co.KG, Hans-Dehn-Str.1, Postfach 1640, D92306
Neumarkt, Germany
Operate the SCALANCE XB-200 with suitable overvoltage protection.
● The power supply is connected using a 3-pin plug-in terminal block (spring-loaded terminal). The terminal block ships with the device and can also be ordered as a spare part.
● The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load.
● The power supply is connected over a high resistance with the enclosure to allow an ungrounded set up. The two power inputs are non-floating.
● To wire up the power connector, use a copper cable of category 24-16 AWG or a cable with a cross-section of 0.25 to 1.5 mm².
● To wire up the functional ground, use a copper cable of category 20-16 AWG or a cable with a cross-section of 0.75 to 1.5 mm².
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
25
Connecting up
4.2 Power supply
Figure 4-1
Contact
L1+
M1
Position of the power supply, for example on the SCALANCE XB213-3
Assignment
24 VDC
Ground
Functional ground
Assignment
24 VDC
Ground
Functional ground
Contact
L2+
M2
26
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Connecting up
4.3 Serial interface
● Via the serial interface (RJ-11 jack), you can access the CLI of the device directly via an
RS-232 connection (115200 8N1) without assigning an IP address.
● Access to the device is also possible independent of the Ethernet ports.
● To connect the serial interface to the PC, you require a cable with an RJ-11 plug and 9pin D-sub female connector. You can order the connecting cable for the serial interface as an accessory.
Figure 4-2 Position and pin assignment of the serial interface (RJ-11 jack), for example on the
SCALANCE XB213-3
3
4
5
6
1
2
7
8
9
The connecting cable listed in the "Accessories" section has the following pin assignment:
Contact Pin assignment of the RJ-11 plug
-
-
-
TD (Transmit Data)
SG (Signal Ground)
RD (Receive Data)
Pin assignment of the D-sub female connector
-
TD (Transmit Data)
RD (Receive Data)
-
-
-
-
SG (Signal Ground)
-
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
27
Connecting up
4.4 Functional ground
Note
Pin assignment of the RJ-11 jack on the device
The RJ-11 jack on the device has a pinout to match the RJ-11 plug of the connecting cable mentioned above.
EMC disturbances are diverted to ground via the functional ground. This ensures the immunity of the data transmission.
The functional ground must be implemented with low impedance. The connection of the functional ground must be established directly on the mounting plate or the DIN rail terminal.
The IE switch has a terminal for functional ground, refer to the section "Power supply
(Page 25)". Keep to the specified cross-sectional area for the functional ground.
The terminal is identified by the following symbol for the functional ground
Follow the steps below to connect the functional ground:
.
1.
Connect the terminal of the IE switch with as short a cable as possible ≤ 150 mm and with the required cross-sectional area to a grounded part of the system (DIN rail).
2.
Connect the DIN rail with the ground of the system.
The connection of the reference potential surface with the protective ground system is normally in the cabinet close to the power feed-in. This ground conducts fault currents to ground safely and according DIN/VDE 0100 is a protective ground to protect people, animals and property from too high contact voltages.
Apart from the protective ground, there is functional grounding in the cabinet. According to
EN60204-1 (DIN/VDE 0113 T1) electrical circuits must be grounded. The chassis (0 V) is grounded at one defined point. Here, once again the grounding is implemented with the lowest leakage resistance to ground in the vicinity of the power feed-in.
With automation components, functional ground also ensures interference-free operation of a controller. Via the functional ground, interference currents coupled in via the connecting cables are discharged to ground.
28
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
5
The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device.
To load new firmware, you require the "RESET" button. When pressing the button,
remember the information in the section "RESET button (Page 16)".
Using TFTP, you can supply a device with new firmware even when it cannot be reached using WBM or CLI. This section explains the procedure based on the example of Microsoft
Windows.
Follow the steps below to load new firmware using TFTP:
1.
Turn off the power to the device.
2.
Press the "RESET" button applying only slight pressure button and reconnect the power to the device while holding down the button.
3.
Hold down the button until the red fault LED "F" starts to flash.
4.
Release the button as long as the red error LED is still flashing..
Note
This time only lasts a few seconds.
The bootloader of the device waits in this status for a new firmware file that you can download by TFTP.
5.
Connect a PC to port 0.1 via an Ethernet cable.
6.
Assign an IP address to the device using DHCP or the Primary Setup Tool.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
29
Upkeep and maintenance
5.1 Downloading new firmware using TFTP without WBM and CLI
7.
Open a Windows command prompt and change to the directory where the file with the new firmware is located and then execute the following command : tftp -i <IP address> put <firmware file>
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP
Client".
8.
Once the firmware has been transferred completely to the device and validated, there is an automatic restart on the device. This may take several minutes.
30
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Upkeep and maintenance
5.2 Restoring the factory settings
Note
When you reset the device parameters, all previously changed settings are lost.
When pressing the button, remember the information in the section "RESET button
Follow the steps below to reset the device parameters to the factory settings with the
"RESET" button:
1.
Turn off the power to the device.
2.
Press the "RESET" button for example with a screwdriver and reconnect the power to the device while holding down the button.
3.
Hold down the button until the red error LED "F" stops flashing after approximately 20 seconds and is permanently lit.
4.
Release the button and wait until the fault LED "F" goes off.
The device starts automatically with the factory settings.
Follow the steps below to reset the device parameters to the factory settings with the PST:
1.
Select the device whose parameters you want to reset.
2.
Click on the menu item "Reset" in the "Module" tab.
3.
Confirm the prompt with "OK".
You will find detailed information on resetting the device parameters using the WBM and CLI
in the configuration manuals (Page 3):
● SCALANCE XB-200 Web Based Management, section "Restart"
● SCALANCE XB-200 Command Line Interface, section "Reset and Defaults"
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
31
Upkeep and maintenance
5.2 Restoring the factory settings
32
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
6
The following technical specifications apply to the SCALANCE XB208.
Technical specifications
Attachment to Industrial Ethernet
Diagnostics interface
Serial interface
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
8
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
•
•
Design
Cable cross-section
Minimum
Maximum
•
•
24 VDC
19.2 to 28.8 VDC Safe Extra Low Voltage (SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Current consumption
Effective power loss
Fusing
Permitted ambient conditions
Ambient temperature
Property at 24 VDC at 24 VDC
Implemented redundantly
170 mA
4.1 W
F 2.5 A / 125 V
During operation up to 2000 m
During storage
During transportation
During operation at 25 ℃
0 ℃ to +60 ℃
-40 ℃ to +70 ℃
-40 ℃ to +70 ℃
≤ 95 % no condensation Relative humidity
Housing, dimensions and weight
Design
Housing material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options compact
Polycarbonate (PC-GF10)
IP20
40 x 117 x 109 mm
250 g
Installation on a DIN rail
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
33
Technical specifications
6.1 Technical specifications of the SCALANCE XB208
Technical specifications
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 84 years
34
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.2 Technical specifications of the SCALANCE XB205-3 (SC)
The following technical specifications apply to the SCALANCE XB205-3 (SC).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
5
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
SC socket
Full duplex acc. to 100Base-FX
100 Mbps
Multimode glass FO cable
-19 dBm
-14 dBm
Diagnostics interface
Serial interface
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
•
•
50/125 μ m
62.5/125 μ m
Quantity
Connector
Cable length
•
•
0 ... 5 km
0 ... 5 km
•
•
-34 dBm
-3 dBm
Attenuation
•
•
≤ 1 dB/km at 1310 nm; 1200 MHz * km
≤ 1 dB/km at 1310 nm; 1200 MHz * km
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
300 mA
*)
7.2 W
F 2.5 A / 125 V
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
35
Technical specifications
6.2 Technical specifications of the SCALANCE XB205-3 (SC)
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
80 x 117 x 109 mm
350 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 55 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
36
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.3 Technical specifications of the SCALANCE XB205-3LD (SC)
The following technical specifications apply to the SCALANCE XB205-3LD (SC).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
5
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
SC socket
Full duplex acc. to 100Base-FX
100 Mbps
Single mode glass FO cable
-15 dBm
-8 dBm
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
• 9/125 μ m
Cable length
• 0 to 26 km
•
•
-32 dBm
-3 dBm
Attenuation
• ≤ 0.5 dB/km at 1310 nm
Diagnostics interface
Serial interface Quantity
Connector
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
290 mA
*)
7 W
F 2.5 A / 125 V
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
37
Technical specifications
6.3 Technical specifications of the SCALANCE XB205-3LD (SC)
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
80 x 117 x 109 mm
350 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 50 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
38
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.4 Technical specifications of the SCALANCE XB205-3
The following technical specifications apply to the SCALANCE XB205-3.
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
5
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
ST(BFOC) socket
Full duplex acc. to 100Base-FX
100 Mbps
Multimode glass FO cable
-19 dBm
-14 dBm
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
•
•
50/125 μ m
62.5/125 μ m
Cable length
•
•
0 ... 5 km
0 ... 5 km
•
•
-32 dBm
-3 dBm
Attenuation
•
•
≤ 1 dB/km at 1310 nm; 1200 MHz * km
≤ 1 dB/km at 1310 nm; 1200 MHz * km
Diagnostics interface
Serial interface Quantity
Connector
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
300 mA
*)
7.2 W
F 2.5 A / 125 V
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
39
Technical specifications
6.4 Technical specifications of the SCALANCE XB205-3
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
80 x 117 x 109 mm
350 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 55 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
40
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.5 Technical specifications of the SCALANCE XB216
The following technical specifications apply to the SCALANCE XB216.
Technical specifications
Attachment to Industrial Ethernet
Diagnostics interface
Serial interface
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
16
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
•
•
Design
Cable cross-section
Minimum
Maximum
•
•
24 VDC
19.2 to 28.8 VDC Safe Extra Low Voltage (SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Current consumption
Effective power loss
Fusing
Permitted ambient conditions
Ambient temperature
Property at 24 VDC at 24 VDC
Implemented redundantly
280 mA
6.7 W
F 2.5 A / 125 V
During operation up to 2000 m
During storage
During transportation
During operation at 25 ℃
0 ℃ to +60 ℃
-40 ℃ to +70 ℃
-40 ℃ to +70 ℃
≤ 95 % no condensation Relative humidity
Housing, dimensions and weight
Design
Housing material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) compact
Polycarbonate (PC-GF10)
IP20
80 x 117 x 109 mm
400 g
Installation on a DIN rail
> 60 years
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
41
Technical specifications
6.6 Technical specifications of the SCALANCE XB213-3 (SC)
The following technical specifications apply to the SCALANCE XB213-3 (SC).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
13
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
SC socket
Full duplex acc. to 100Base-FX
100 Mbps
Multimode glass FO cable
-19 dBm
-14 dBm
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
•
•
50/125 μ m
62.5/125 μ m
Cable length
•
•
0 ... 5 km
0 ... 5 km
•
•
-34 dBm
-3 dBm
Attenuation
•
•
≤ 1 dB/km at 1310 nm; 1200 MHz * km
≤ 1 dB/km at 1310 nm; 1200 MHz * km
Diagnostics interface
Serial interface Quantity
Connector
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
410 mA
*)
9.8 W
F 2.5 A / 125 V
42
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.6 Technical specifications of the SCALANCE XB213-3 (SC)
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
120 x 117 x 109 mm
500 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 45 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
43
Technical specifications
6.7 Technical specifications of the SCALANCE XB213-3LD (SC)
The following technical specifications apply to the SCALANCE XB213-3LD (SC).
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
13
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
SC socket
Full duplex acc. to 100Base-FX
100 Mbps
Single mode glass FO cable
-15 dBm
-8 dBm
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
• 9/125 μ m
Cable length
• 0 to 26 km
•
•
-32 dBm
-3 dBm
Attenuation
• ≤ 0.5 dB/km at 1310 nm
Diagnostics interface
Serial interface Quantity
Connector
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
400 mA
*)
9.6 W
F 2.5 A / 125 V
44
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.7 Technical specifications of the SCALANCE XB213-3LD (SC)
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
120 x 117 x 109 mm
500 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 40 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
45
Technical specifications
6.8 Technical specifications of the SCALANCE XB213-3
The following technical specifications apply to the SCALANCE XB213-3.
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Optical connectors
•
•
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
Minimum
Maximum
•
•
13
RJ-45 jack
Half/full duplex, MDI-X pinning
10 / 100 Mbps
3
ST(BFOC) socket
Full duplex acc. to 100Base-FX
100 Mbps
Multimode glass FO cable
-19 dBm
-14 dBm
Receiver input
•
•
Sensitivity min.
Input power max.
Cable cross-section
•
•
50/125 μ m
62.5/125 μ m
Cable length
•
•
0 ... 5 km
0 ... 5 km
•
•
-32 dBm
-3 dBm
Attenuation
•
•
≤ 1 dB/km at 1310 nm; 1200 MHz * km
≤ 1 dB/km at 1310 nm; 1200 MHz * km
Diagnostics interface
Serial interface Quantity
Connector
1
RJ-11 jack
Electrical data
Power supply Rated voltage
Voltage range
Current consumption
Effective power loss
Fusing
•
•
Design
Cable cross-section
Minimum
Maximum
Properties at 24 VDC at 24 VDC
•
•
24 VDC
19.2 to 28.8 VDC Safety Extra Low Voltage
(SELV)
Terminal block, 3 terminals
0.25 mm
2
(24 AWG)
1.5 mm
2
(16 AWG)
Implemented redundantly
410 mA
*)
9.8 W
F 2.5 A / 125 V
46
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.8 Technical specifications of the SCALANCE XB213-3
Technical specifications
Permitted ambient conditions
Ambient temperature During operation up to 2000 m 0 ℃ to +60 ℃
Relative humidity
Housing, dimensions and weight
Design
During storage
During transportation
During operation at 25 ℃
-40
-40
≤
℃
℃
to +70
to +70
℃
℃
95 % no condensation
Housing material
Degree of protection
Dimensions (W x H x D)
Weight compact
Polycarbonate (PC-GF10)
IP20
120 x 117 x 109 mm
500 g
Installation on a DIN rail Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C) > 45 years
)
*
For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
47
Technical specifications
6.9 Cable lengths
The following technical specifications apply to the following devices:
● SCALANCE XB208
● SCALANCE XB205-3 (SC)
● SCALANCE XB205-3LD (SC)
● SCALANCE XB205-3
● SCALANCE XB216
● SCALANCE XB213-3 (SC)
● SCALANCE XB213-3LD (SC)
● SCALANCE XB213-3
Cable
IE TP torsion cable with IE FC Outlet RJ-45 + 10 m TP cord
IE TP torsion cable with IE FC RJ-45 Plug 180
IE FC TP Marine / Trailing / Flexible cable with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP Marine / Trailing / Flexible cable with IE FC RJ-45 Plug 180
IE FC TP standard cable with IE FC Outlet RJ-45 + 10 m TP cord
IE FC TP standard cable with IE FC RJ-45 Plug 180
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
48
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Technical specifications
6.10 Switching properties
The following technical specifications apply to the following devices:
● SCALANCE XB208
● SCALANCE XB205-3 (SC)
● SCALANCE XB205-3LD (SC)
● SCALANCE XB205-3
● SCALANCE XB216
● SCALANCE XB213-3 (SC)
● SCALANCE XB213-3LD (SC)
● SCALANCE XB213-3
Switching properties
Aging time
Max. number of learnable addresses
Switching technique
Latency
Full wire speed switching:
Note
Can be configured (default value: 40 seconds)
8192
Store and forward
10 microseconds
Number of frames per second (at 100 Mbps)
148810
84459
45290
23496
11973
9615
8127
Frame length
64 bytes
128 bytes
256 bytes
512 bytes
1024 bytes
1280 bytes
1518 bytes
The number of SCALANCE XB-200 modules connected in a line influences the frame delay.
When a frame passes through the switch, this is delayed by the store-and-forward function of the SCALANCE XB-200 by 10-130 microseconds (at 100 Mbps).
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
49
Technical specifications
6.10 Switching properties
50
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Note
Dimensions are specified in mm.
7
Figure 7-1 Width and height
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
51
Dimension drawings
52
Figure 7-2 Width and height based on the example of the SCALANCE XB205-3
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Dimension drawings
Figure 7-3 Width and height based on the example of the SCALANCE XB213-3
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
53
Dimension drawings
Figure 7-4 Depth
54
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
A
The SIMATIC NET products described in these Operating Instructions have the approvals listed below.
Note
Issued approvals on the type plate of the device
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the markings on the type plate.
You will find the current approvals for the product on the Internet pages of Siemens Industry
Online Support ( http://support.automation.siemens.com/WW/view/en/33118389/134200 ).
→ Entry type "Certificates"
SIMATIC NET products meet the requirements and aims of the following EC directives.
The SIMATIC NET products described in these operating instructions meet the requirements of EC directive 2004/108/EC "Electromagnetic Compatibility" for the following areas of application:
Field of application
Industry
Emission
EN 61000-6-4 : 2007
Requirements
Immunity to interference
EN 61000-6-2 : 2005
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
55
Approvals
WARNING
Personal injury and property damage can occur
The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility.
Only use expansions that are approved for the system.
● Keep to the installation guidelines
The devices meet the requirements if you adhere to the installation and safety instructions contained in this documentation and in the following documentation when installing and operating the devices.
● You can always find the latest documentation on the Internet
The current descriptions of the currently available products can always be found on the
Internet under the specified entry IDs/Internet pages:
– "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual
– "Industrial Ethernet / PROFINET - Passive network components" System Manual
You will find information on the system manuals in the section "Introduction (Page 3)",
in "Further documentation".
– "EMC Installation Guidelines" configuration manual
60612658 ( http://support.automation.siemens.com/WW/view/en/60612658 )
● Working on the device
To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
Note
The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above.
When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed.
In the version put into circulation by Siemens AG, the SIMATIC NET products described in these Operating Instructions conform to the regulations of the following European directive:
● EN 60950-1
Information technology equipment - Safety - Part 1: General requirements
You will find EC declaration of conformity for these products on the Internet pages of
Siemens Industry Online Support
( http://support.automation.siemens.com/WW/view/en/33118389/134200 ).
56
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
Approvals
WARNING
When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to:
"SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous
Area".
You will find this document
•
• on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support
( http://support.automation.siemens.com/WW/view/en ).
Enter the document identification number C234 as the search term.
SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and
Protective Devices for Use in Potentially Explosive Atmospheres".
ATEX classification:
II 3 G Ex nA IIC T4 Gc
KEMA 07ATEX0145 X
The products meet the requirements of the following standards:
● EN 60079-15 (electrical apparatus for potentially explosive atmospheres; Type of protection "n")
● EN 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid ATEX certificates.
The SIMATIC NET products meet the requirements of explosion protection according to
IECEx.
IECEx classification:
Ex nA IIC T4 Gc
DEK 14.0025X
The products meet the requirements of the following standards:
● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n")
● IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements)
You will find the current versions of the standards in the currently valid IECEx certificates.
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
57
Approvals
The product meets the requirements of the standards:
● Factory Mutual Approval Standard Class Number 3611
● FM Hazardous (Classified) Location Electrical Equipment:
Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and
Non Incendive / Class I / Zone 2 / Group IIC / T4
cULus Listed I. T. E.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● CSA C22.2 No. 60950-1-03
Report no. E115352
cULus Listed I. T. E. FOR HAZ. LOC.
Underwriters Laboratories Inc. complying with
● UL 60950-1 (Information Technology Equipment)
● ANSI/ISA 12.12.01-2007
● CSA C22.2 No. 213-M1987
Approved for use in
Cl. 1, Div. 2, GP A, B, C, D T4
Cl. 1, Zone 2, GP IIC T4
Report no. E240480
The product meets the requirements of the AS/NZS 2064 standard (Class A).
The products meet the requirements of the "Korean Standard".
EAC (Eurasian Conformity)
Customs union of Russia, Belarus and Kazakhstan
Declaration of the conformity according to the technical regulations of the customs union
(TR CU)
58
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
The following devices meet the FDA and IEC requirements listed below:
Device
SCALANCE XB208
SCALANCE XB205-3 (SC)
SCALANCE XB205-3LD (SC)
SCALANCE XB205-3
SCALANCE XB216
SCALANCE XB213-3 (SC)
SCALANCE XB213-3LD (SC)
SCALANCE XB213-3
CLASS 1 LASER Product
-
-
-
-
●
-
●
-
-
●
-
●
-
●
CLASS 1 LED Product
-
●
Approvals
Figure A-1 FDA and IEC approvals
CAUTION
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Device IEC 60068-2-27 shock
15 g, 11 ms duration
6 shocks per axis
SCALANCE XB208
SCALANCE XB205-3
SCALANCE XB205-3 (LD)
SCALANCE XB205-3 (ST)
SCALANCE XB216
SCALANCE XB213-3
SCALANCE XB213-3 (LD)
SCALANCE XB213-3 (ST)
●
●
●
●
●
●
●
●
IEC 60068-2-6 vibration
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
●
●
●
●
●
●
●
●
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
59
Ambient temperature, 33, 36, 38, 40, 41, 43, 45, 47
Attachment to Industrial
Ethernet, 33, 35, 37, 39, 41, 42, 44, 46
Installation, 33, 36, 38, 40, 41, 43, 45, 47
Installation on a DIN rail, 21
Installation on a DIN rail, 21
Command Line Interface, 27, 29
Connecting up
MTBF, 34, 36, 38, 40, 41, 43, 45, 47
Dimensions, 33, 36, 38, 40, 41, 43, 45, 47
Electrical data, 33, 35, 37, 39, 41, 42, 44, 46
Environmental conditions, 33, 36, 38, 40, 41, 43, 45, 47
RESET button, 13, 14, 15, 16, 29
Permitted ambient
conditions, 33, 36, 38, 40, 41, 43, 45, 47
Safety notices
Use in hazardous areas, 9, 19, 23 when connecting up, 23
Serial interface, 13, 14, 15, 27
Housing, 33, 36, 38, 40, 41, 43, 45, 47
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
61
Index
Weight, 33, 36, 38, 40, 41, 43, 45, 47
62
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03