AMX
IP Link® De vice Interface
Communication Sheet
amx_2_4448_1.pke
Revision: 8/10/2010
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Device Specifications:
Device Type:
Manufacturer:
Firmware Version:
Model(s):
Switcher
AMX
N/A
AVS- SL-PR-0401-0601
Version History:
Driver
Version
Date
1
8/3/2010
IP Link
Compiler
GC
Version
1.4.0
3.0.3
Notes
Initial version.
Driver Notes:
Device ID must match ID of switcher. Default ID is 0.
Pass through mode is not recommended with this driver.
Page 1 of 5
IP Link® De vice Interface
Communication Sheet
amx_2_4448_1.pke
Revision: 8/10/2010
Control Commands & States:
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
AV Mute
On
Off
De vice ID
0-255
Exe cutive Mode
On
Off
Vide o Input
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
A/V Input
Audio Input
Volume (Discre te)
-90 to 0 in steps of 1
Volume (Ste p)
Up
Down
Page 2 of 5
IP Link® De vice Interface
Communication Sheet
amx_2_4448_1.pke
Revision: 8/10/2010
Status Available:
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
Connection Status
Connected
Disconnected
De vice ID
0-255
Vide o Input
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
Audio Input
Volume (Discre te)
-90 to 0 in steps of 1
Page 3 of 5
IP Link® De vice Interface
Communication Sheet
amx_2_4448_1.pke
Revision: 8/10/2010
MLC62 Supported Commands*:
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
AV Mute
On
Off
Exe cutive Mode
On
Off
Vide o Input
PC1
PC2
PC3
PC4
Video 1
Video 2
Video 3
Video 4
Video 5
Video 6
Blank
A/V Input
Audio Input
Volume (Discre te)
-90 to 0 in steps of 1
Volume (Ste p)
Up
Down
*MLC62 will only work with a device with ID 0.
Page 4 of 5
amx_2_4448_1.pke
IP Link® De vice Interface
Communication Sheet
Revision: 8/10/2010
Cable and Adapter Requirements:
RS232 DB9 Serial Cable to Captive Screw
Notes for the Device:
Serial communication:
Port Type : RS-232
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Pin Assignments Diagram:
Note: Captive screw connector may also be used as a serial connection.
General Notes: