VENT-FREE

GAS LOG SET

MODEL # VFL-CY24DR

VFL-HT24DR

VFL-CY30DR

VFL-HT30DR

WARNING: This appliance is equipped for (Natural and

Propane) gas. Field conversion is not permitted other than between natural or propane gases.

NG LP

Dual Fuel

CAUTION - FOR YOUR SAFETY

0418GL011S

ANSI Z21.60-2012

WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY

DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

- Do not store or use gasoline or other flammable vapors and Iiquids in vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air most be provided.

Refer to Air For Combustion and Ventilation section on page 8 of this manual.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket, permanently located manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with propane or natural gas. This appliance is equipped with a simple means to switch between propane and natural gas. Field conversion by any other means including the use of a kit is not permitted.

Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m., CST, Monday – Friday or email us at [email protected].

IMEBLS - 2015-03-31

1

TABLE OF CONTENTS

Specifications ................................................................................................................................... 2

Important Safety Information ............................................................................................................3

Product Identification ........................................................................................................................ 5

Product Features .............................................................................................................................. 6

Preparing for Installation................................................................................................................... 7

Installation ...................................................................................................................................... 10

Unpacking....................................................................................................................................... 15

Log Assembly ................................................................................................................................. 21

Operation ........................................................................................................................................ 23

Remote Control Operation.............................................................................................................. 25

Care and Maintenance ................................................................................................................... 32

Troubleshooting .............................................................................................................................. 34

Replacement Parts ......................................................................................................................... 37

Accessories .................................................................................................................................... 37

Warranty ......................................................................................................................................... 38

WARNING: Read the Installation & Operating Instructions before using this appliance.

IMPORTANT: Read all instructions and warnings carefully before starting installation.

Failure to follow these instructions may result in possible injury to persons or a fire hazard and will void the warranty.

ITEM VFL-CY24DR

VFL-HT24DR

VFL-CY30DR

VFL-HT30DR

Input Rating

Gas Type

33,000 BTU/Hr

Natural LP/Propane

33,000 BTU/Hr

Natural LP/Propane

Ignition Electronic Piezo Electronic Piezo Electronic Piezo Electronic Piezo

Manifold Pressure 4.5 in. W.C. 10 in. W.C. 4.5 in. W.C. 10 in. W.C.

Inlet Gas Pressure *For purposes of input adjustment

Maximum 7 in. W.C. 14 in. W.C.

Minimum* 5.5 in. W.C. 11 in. W.C.

7 in. W.C.

5.5 in. W.C.

14 in. W.C.

11 in. W.C.

WRONG FUEL SHUT DOWN SYSTEM

This heater is equipped with a pressure activated dual circuit that will not allow the main burner to ignite if the incorrect fuel is installed. Inlet gas pressures, listed on page 2 of this Owner's Manual, must be correct for this system to work reliably. Excessive NG inlet gas pressure will activate the

"wrong fuel shut down system" and the heater will not light.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

2

IMPORTANT SAFETY INFORMATION

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

Only a qualified installer, service agent, or local gas supplier may install and service this product.

WARNING: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

WARNING: This appliance can be used with propane or natural gas. It is shipped from the

factory adjusted for use with propane.

CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly.

Get fresh air immediately! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease, people who are anemic, those under the influence of alcohol, and those living in high altitudes.

NATURAL AND PROPANE/LP GAS: Natural and Propane/LP gases are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to operating this heater safely.

WARNING:

- Due to high temperatures, locate this appliance out of traffic and away from furniture and draperies.

- Heater becomes very hot when operating. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Heater will remain hot for a time after shutoff.

Allow surfaces to cool before touching.

- Carefully supervise young children when they are in the room with the heater.

- Do not place clothing or other flammable material on or near the appliance. Never place any objects in the heater.

- Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person.

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

- Any change to this heater or its controls can be dangerous.

- Do not use any accessories not approved for use with this heater.

- Keep the appliance are clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

- This appliance is intended for supplemental heating.

CALIFORNIA PROPOSITION 65

Fuels used in gas or oil fired appliances and the products of combustion of such fuels contain chemicals known to the state of California to cause cancer, birth defects or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the state of

California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.

3

SAFETY INFORMATION

1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use any phone in your building

• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the fire department

4. This heater shall not be installed in a bedroom or bathroom.

5. Do not use this heater as a wood-burning heater. Use only the logs provided with the heater.

6. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of heater.

7. This heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

8. To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 32-33.

9. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

10. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion

Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 9. If heater keeps shutting off, see

Troubleshooting, page 27.

11. Do not run heater

• where flammable liquids or vapors are used or stored.

• under dusty conditions.

12. Do not use this heater to cook food or burn paper or other objects.

13. Never place any objects in the heater or on logs.

14. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

15. Only a qualified service person should service and repair heater.

16. Operating heater above elevations of 4,500 feet could cause pilot outage.

17. Do not operate heater if log is broken. Do not operate heater if log is chipped (dime-sized or larger).

18. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.

19. Provide adequate clearances around air openings.

20. A fireplace screen must be in place when the heater is operating.

QUALIFIED INSTALLING AGENCY

Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and equipment servicing. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for: a) Installing, testing, or replacing gas piping or b)Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required; and that has complied with all the requirements of the authority having jurisdiction.

4

PRODUCT IDENTIFICATION

Grate Cap

Grate

Log Locator Pin

2-Places

Ember Bed

Receiver

NG ODS Pilot

LP ODS Pilot

Burner Tube

Piezo Ignitor

Control Valve

Receiver Heat Shield

5

PRODUCT FEATURES

This log set has been tested and approved to ANSI Z21.11.2-2013 standard for Unvented Heaters and can be operated with the flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters.

DUAL FUEL CAPABILITY

Your heater is equipped to operate on either propane or natural gas. The heater is shipped from the factory ready for connecting to propane. The heater can easily be changed to natural gas by having your qualified installer follow the instructions on page

16 and the markings on the heater.

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.

The ODS/pilot shuts off the heater if there is not enough fresh air and cuts off main burner gas in the event of flame out.

ELECTRIC PUSH BUTTON IGNITION SYSTEM

This heater is equipped with an electronic piezo control system. This system requires one AAA battery (provided).

THERMOSTAT HEAT CONTROL

The control automatically cycles the burner on and off to maintain a desired room temperature (See page 24). When used as a vented decorative appliance, use of the thermostat function is prohibited, operate manually only.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in

the Commonwealth of Massachusetts. Sellers of unvented propane or natural gas-fired

supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale

of the unit.

In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall

be prohibited in bedrooms and bathrooms.

In the State of Massachusetts the gas cock must be a T-handle type. The State of

Massachusetts requires that a flexible appliance connector cannot exceed three feet

in length.

LOCAL CODES

Install and use heater with care. Follow all codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*.

*Available from:

American National Standard Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA 02269-9101

This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.

The installation of appliances designed for manufactured home (U.S. only) or mobile home installation must conform with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA

501A, Manufactured Home Installations Standard.

6

PREPARING FOR INSTALLATION

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30 mL) of water for every 1,000 BTUs (.3 kw) of gas input per hour. An unvented room heater is recommended as a supplemental heater (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

The following steps will help ensure that water vapor does not become a problem:

1. Be sure the heater is the proper size for the application, including adequate combustion air and

circulation air.

2. If there is high humidity, a dehumidifier may be used to help lower the water vapor content

of the air.

3. Do not use an unvented room heater as the primary heat source.

AIR FOR COMBUSTION AND VENTILATION

This heater shall not be installed in a room or space unless the required volume of indoor combustion air is provided by the method described in the Nation Fuel Gas Code, ANSI Z223.1/NFPA 54, the

International Fuel Gas Code, or applicable local codes.

PRODUCING ADEQUATE VENTILATION

All spaces in homes fall into one of the three following ventilation classifications:

1. Unusually Tight Construction

2. Unconfined Space

3. Confined Space

The information on pages 8-10 will help you classify your space and provide adequate ventilation.

Confined and Unconfined Space

A confined space as a space whose volume is less than 50 cu. ft. per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfining space as a space whose volume is not less than 50 cu. ft. per 1,000 BTU/hr (4.8 m^3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms connecting directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

* Adjoining rooms are connecting only if there are doorless passageways or ventilation

grills between them.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where: a) walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder

with a rating of one perm (6x10-11kg per pa-sec-m2) or less with openings gasketed or sealed

and b) weather stripping has been added on windows that can be opened and on doors and c) caulking or sealants are applied to areas such as joints around window and door frames,

between sole plates and floors, between wall-ceiling joints, between wall panels, at

penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air.

See “Ventilation Air From Outdoors” (page 9). If your home does not meet all of the three criteria above, proceed to “Determining Fresh-Air Flow For Heater Location”.

7

PREPARING FOR INSTALLATION

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this worksheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1. Determine the volume of the space Length × Width × Height = cu. ft. (volume of space)

Example: Space size 20 ft. (length) × 16 ft.(width) × 8 ft. (ceiling height) = 2560 cu. ft. (volume

of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2. Divide the space volume by 50 cu. ft. to determine the maximum BTU/hr the space can support.

_______ (volume of space) ÷ 50 cu. ft.= (Maximum BTU/hr the space can support)

Example: 2560 cu. ft. (volume of space) ÷ 50 cu. ft. = 51.2 or 51,200 (maximum BTU/hr the space

can support)

3. Add the BTU/hr of all fuel burning appliances in the space.

Vent-free heater _________ BTU/hr

Gas water heater* ________BTU/hr

Gas furnace _____________BTU/hr

Vented gas heater ________BTU/hr Example:

Gas heater logs __________BTU/hr Gas water heater 30,000 BTU/hr

Other gas appliances*+ ____BTU/hr Vent-free heater + 26,000 BTU/hr

Total = ____BTU/hr Total = 56,000 BTU/hr

*Do not include direct-vent gas appliances. Direct-vent draws combustion air from the

outdoors and vents to the outdoors.

4. Compare the maximum BTU/hr the space can support with the actual amount of BTU/hr used.

_______ BTU/hr (maximum the space can support)

_______ BTU/hr (actual amount of BTU/hr used).

Example : 51,200 BTU/hr (maximum the space can support) 56,000 BTU/hr (actual amount of

BTU/hr used)

The space in the above example is a confined space because the actual BTU/hr used is more than the maximum BTU/hr the space can support.

You must provide additional fresh air. Your options are as follows: a) Rework worksheet, adding the space of an adjoining room. If the extra space provides an

unconfined space, remove door to adjoining room or add ventilation grills between rooms. See

“Ventilation Air From Inside Building,” page 9.

b) Vent room directly to the outdoors. See “Ventilation Air From Outdoors”, page 9.

c) Install a lower BTU/hr heater if lower BTU/hr size makes room unconfined. If the actual BTU/hr

used is less than the maximum BTU/hr the space can support, the space is an unconfined space.

You will need no additional fresh air ventilation.

8

PREPARING FOR INSTALLATION

WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in the NATIONAL FUEL GAS CODE, ANSI Z223.1/NFPA

54, the INTERNATIONAL FUEL GAS CODE, or applicable local codes.

Ventilation Air From Inside Building

This fresh air would come from adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12 in. of the wall connecting the two spaces (see options 1 and 2,

Fig. 1). You can also remove door into adjoining room (see option 3, Fig. 1).

Follow the National Fuel Gas Code

NFPA 54/ANS Z223.1. Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or duct. You must provide two permanent openings: one within 12 in. of the ceiling and one within 12 in. of the floor.

Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

Follow the National Fuel Gas Code NFPA

54/ANS Z223.1. Air for Combustion and

Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent. Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Fig 1 - Ventilation Air from Inside Building

12 in.

Ventilation Grills

Into adjoining Room

Option 2

Fig. 1 - Ventilation Air from

Ventilated

Attic

Or

Remove

Door

Into

Adjoining

Room

Option 3

Ventilation

Grills

Into Adjoining

Room

Option 1

Outlet

Air

Outlet

Air

To

Crawl

Space

To

Attic

Inlet

Air

Ventilated

Crawl Space

Inlet Air

Fig. 2 - Ventilation Air from Outdoors

9

INSTALLATION

WARNING: Do not attempt to access or change the setting of the fuel selection means.

Access to and adjustment of the fuel selection means must only be a performed by a qualified service person when connecting this appliance to a specified fuel supply at the time of installation.

Change of the selector setting to other than the fuel type specified at the time of installation could damage this appliance and render it inoperable.

The installer shall replace the access cover before completing the installation and operating this appliance.

NOTICE:

primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house.

WARNING: A qualified technician must install heater. Follow all local codes.

WARNING: Never install the heater:

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture, clothing, or other flammable objects are less than 42 in. from the front, top or sides of the heater.

• in high traffic areas

• in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities

(such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may cause walls to discolor.

WARNING: Any glass doors shall be fully opened when the appliance is in operation.

WARNING: Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

IMPORTANT: Vent-free heaters add moisture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for

Combustion and Ventilation, pages 8 through 10.

CHECK GAS TYPE

Be sure your gas supply is right for your heater.

NOTICE: State or local codes may only allow operation of this appliance in a vented configuration.

Check your state or local codes.

WARNING:

UL 127 factory-built fireplace or in a listed ventless firebox enclosure. Exception: DO NOT install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: Solid-fuels shall not be burned in a fireplace in which an unvented room heater is installed.

WARNING: Any outside air ducts and/or ash dumps in the fireplace shall be permanently closed at time ofappliance installation.

10

INSTALLATION

CHECK GAS TYPE

Make sure your gas supply is correct for your log set. If supply is not correct, do not install heater. Call dealer where you purchased heater for proper gas log set.

LOG SIZING REQUIREMENTS

Log Size Minimum Firebox Size

24 in.

30 in.

Height

24 in.

24 in.

Depth

15 in.

15 in.

Front Width

32 in.

36 in.

Rear Width

22 in.

24 in.

Heater CLEARANCES

CAUTION: If you install the heater in a home garage

• heater pilot and burner must be at least 18" above floor.

• locate heater where moving vehicle will not hit it.

For convenience and efficiency, install heater

• where there is easy access for operation, inspection and service

• in coldest part of room

• If this appliance is to be installed directly on carpeting, tile or other combsutible material, other than wood flooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

Minimum Clearances For Side Combustible Material, Side Wall and Ceiling

A. Clearances from the side of the heater cabinet to any combustible material and wall should follow diagram in Figure 2.5.

B. Clearances from the top of the heater opening to the ceiling should not be less than 36".

WARNING:

floor, ceiling, and adjoining wall than required.

Fig. 2.5

Minimum Fireplace Clearance to Combustible Materials

Log size Side wall Ceiling

WARNING:

place to prevent drafting caused by pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

11

INSTALLATION

MINIMUM NONCOMBUSTIBLE MATERIAL CLEARANCE

If Not Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 in. thick. With sheet metal, you must have noncombustible material behind it, such as a noncombustible fireplace hood accessory. See Fig. 4.

NOTICE: This heater may be used as a vented product. If so, you must always operate log set with chimney flue damper open. If running log set with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for

Vented Operation, page 14. When used as a vented decorative appliance, use of the thermostat function is prohibited, operate manually only.

Fig. 3 - Minimum Clearance for Combustible to Wall Fig. 4 - Heat resistant material (slate, marble, tile,etc.) above fireplace

Heat Resistant

Material

Material

If Using Mantel

You must have noncombustible material(s) (such as slate, marble, tile, etc.) at least 1/2 in. thick.

With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8 inches up. If noncombustible material is less than 12 in., you must install the fireplace hood accessory. Even if noncombustible material is more than 12 in., you may need the hood accessory to deflect heat away from mantel shelf. See Fig. 3 and 4 for minimum clearances requirements.

IMPORTANT: If these minimum clearances are not met, you must operate heater with chimney flue damper open. Go to “Installing Damper Clamp Accessory for Vented Operation,” page 14.

12

INSTALLATION

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If the clearances listed below are not met, you will need a hood.

Determining Mantel Clearances

If you meet minimum clearance requirements between mantel shelf and top of fireplace opening, a hood is not necessary (see Fig. 5).

Noncombustible

Material Distance

8 in. or more

Less than 8 in.

Requirements for Safe Installation

Noncombustible material okay.

Noncombustible material must be extended to at least 8 in. See between 8 in. and 12 in. above. If you can not extend material, you must operate heater with flue damper open.

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Fig. 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Fig. 6 when using a hood.

Maximum

10"

Combustible

Mantel

Minimum

23"

Maximum

10"

Combustible

Mantel

Maximum

2.5" Minimum

10"

Minimum

18"

4" Sheet

Metal Hood

Fig. 5

Closed Flue Mantel Clearances

Without Hood

Fig. 6

Closed Flue Mantel Clearances

With Hood

NOTICE: Surface temperature of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become too hot to touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following: Operate the logs with the flue damper open only. Raise the mantel to an acceptable height.

13

INSTALLATION

FLOOR CLEARANCES

a) If installing appliance on floor level, you must maintain the minimum distance of 14 in. to

combustibles (see Fig. 7).

b) If combustible materials are less than 14 in. to the fireplace, you must install appliance at least

5 in. above the combustible flooring (see Fig. 8).

Fig. 8 - Minimum fireplace clearances above combustible flooring

Fig. 7 - Minimum fireplace clearances if installed at floor level

Combustible

Material

Combustible

Material

5 in.

Min

Hearth

Hearth

5in.

Min

Combustible

Material

14 in.

Min

NonCombustible

Material

Fig. 9 - Attach Damper to Fireplace

Damper

Damper

"Opened Position"

Damper Clamp

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

NOTE: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue constructed of noncombustible material. You may use this heater as a vented product. When used as a vented decorative appliance, use of the thermostat function is prohibited, operate manually only. There are three reasons for operating your heater as a vented model:

1. The fireplace does not meet the clearance requirements for vent-free operation.

2. State or local codes do not permit vent-free operation.

3. You prefer vented operation.

14

INSTALLATION

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Before beginning assembly or operation of the product, make sure all parts are present.

Compare parts with package contents list. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts.

Estimated Assembly Time: 1 to 2 hours

Tools Required for Assembly (Not Included, unless otherwise stated):

Before installing heater, make sure you have the the following:

• Hardware package (provided with heater)

• Approved flexible gas hose if allowed by local codes

• Sealant (resistant to natural or propane/LP gas)

• Electric drill with 3/16- in. drill bit

• Phillips screwdriver

• External regulator (supplied by installer if required)

• Piping (check local codes)

• Equipment shutoff valve

• Test gauge connection

• Sediment trap

• Tee joint

• Pipe wrench

• 3/8" NPT to 3/8" flare fitting

UNPACKING

1. Remove logs, grate, and burner base assembly from carton. NOTE: Do not pick up burner base

assembly by burners as this could damage heater. Always handle base assembly by frame.

2. Remove all protective packaging applied to logs and heater for shipment.

3. Check all items for any shipping damage. If damaged, promptly inform dealer where you

purchased the heater.

Fig. 10

GRATE ASSEMBLY PROCEDURE

1. Position the grate in front of the burner

so the 2 legs are pointing downward, the

"grate ends" that the logs sit on are point-

ing upward, and the screw holes line up

with the screw holes on the burner unit

(See Fig. 10)

2. Hand tighten the grate to the burner with

(2) Attachment Screws, each at an equal

distance until hand tightening is no

longer possible

3. Finish tightening each Attachment Screw

with a screw driver, but make sure not to

over tighten.

Grate Attachment

Screws

Grate

VFL-EM24DR & VFL-EM30DR

15

INSTALLATION

GAS SELECTION INSTRUCTIONS

WARNING: This appliance can be used with propane or natural gas. It is shipped from the factory adjusted for use with propane.

CAUTION: The knob to the gas selection means shall not be accessed or adjusted while the appliance is in operation.

CAUTION: Two gas line installations at the same time are prohibited. The access plate to simple switching means shall not be opened while heater is in operation.

Installation and adjustments shall be made by a qualified technician only.

NOTE: If you are connecting this appliance to propane do not make any adjustments. Proceed to installing the gas line as instructed in the Owner’s Manual.

Convert to natural gas:

Step 1 - Remove access panel

Regulator Cap

Access Panel

Step 2 - Converting the regulator

Panel Screws (4)

Unscrew the cap on top of the pressure regulator by turning it counter clockwise. Unscrew the plunger pin from the regulator cap by turning it counter clockwise. Flip the plunger pin 180 degrees and screw it back into the regulator cap by turning it clockwise. Replace the cap by turning it clockwise back onto the regulator. Make sure the plunger pin and cap are finger tight. (See Fig. 11)

REGULATOR CAP

PLUNGER PIN

REGULATOR

Counter Clockwise

Clockwise

Gas Selector Knob

Propane

Position

Natural Gas

Position

Unscrew Regulator Cap Unscrew Plunger Pin Flip Plunger Pin 180 Degrees and screw back into Cap

Replace Cap

Fig. 11 - Regulator Conversion

Step 3 - Adjust the gas selector valve

Push in on the selector valve Knob and rotate the knob counter clockwise until it stops. Release the knob (See Fig. 12)

Ensure microswitch trips in correct position (see Fig. 12)

Do not operate the appliance between locked positions.

Step 4 - Replace Access Panel

Reverse steps 1 and 2 to convert back to propane gas.

16

LP Position NG Position

Fig. 12 - Selector Valve

Fig. 12 - Selector Valve

INSTALLATION

CONNECTING TO GAS SUPPLY

WARNING: A qualified service technician must connect heater to gas supply. Follow all local

codes.

CAUTION: Never connect heater directly to the gas supply. This heater requires an external regulator (not supplied). The external regulator between the gas supply and heater must be installed.

Gas supplier provides external regulator for natural gas.

WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known

as wellhead gas.

The installer must supply an external regulator for liquid propane. The external regulator is provided by the gas supplier for natural gas. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 in. of water column for propane and between 6 and 7 in. of water column for natural gas. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Fig. 13. Pointing the vent down protects it from freezing rain or sleet.

Approved

Flexible

Gas Line or 1/2''

Black Pipe

Fig. 13 - Regulator Conversion

6''

7''

Fig. 14 - Gas Connection

* Purchase the optional equipment shutoff valve from your local Home Center store.

CAUTION: Use only new black iron or steel pipe. Internally tinned copper tubing

may be used in certain areas. Check your local codes. Use pipe of ½ in. diameter

or greater to allow proper volume gas to heater. If pipe is too small, loss of pressure

will occur. Installation must include an equipment shutoff valve, union, and plugged

1/8-in. NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must

be upstream from heater (See Fig. 14).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe.

Excess sealant in pipe could result in clogged heater valves.

17

INSTALLATION

CAUTION: Use pipe joint sealant that is resistant to gas (PROPANE or NG). We

recommend that you install a sediment trap in a supply line. Locate sediment trap where it is within

reach for cleaning and not likely to freeze. Install in the piping system between fuel supply and

heater. A sediment trap traps moisture and contaminants. This keeps them from going into heater

controls. If sediment trap is not installed or is installed incorrectly, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when

connecting into gas piping and/or fittings. NG Models: 6 in. to 7 in. W.C. Gas

supplier provides external regulator for natural gas.

Installation Items Needed (Not Provided)

• 8'' Adjustable Wrench

• 8'' Pipe Wrench

• 3/8'' Flexible Gas Line (24'' Min.) or 1/2'' Black Pipe

• 90 Deg. 3/8 NPT x 3/8'' Flare Fitting or 3/8'' Street Elbow

• Sealant (Resistant to Propane (LP) Gas)

• Shut Off Valve

1) A variety of options are possible for routing the Gas Connection Lines depending on where

your Gas Supply line is located. Install the 3/8'' Fitting to the Heater Regulator

using Sealant and direct the attachment and either left or right toward the Gas Supply Line.

NOTICE: Most building codes do not permit concealed gas connections. Check your local building code prior to using a Flexible Gas Line for this installation.

2) Install the Gas Line to the 90 Deg. fitting and attach to the Shut Off Valve. It may be

necessary to cut and access hole in the side or bottom of the Mantel Cabinet depending on

your particular connection.

3) Check all connections for gas leaks.

To Regulator

Flexible Gas Line or

Black Pipe to Heater

Cabinet Regulator

Convertible

Regulator

Gas Inlet to Regulator

18

Fig. 15 - Attaching Flexible Gas Line to Equipment Shutoff Valve

INSTALLATION

CHECKING GAS CONNECTIONS

leaks immediately.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. If bubbles form, there may be a leak. Correct all leaks immediately.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG ( 3.5kPa )

1. Disconnect heater with its appliance main gas valve (control valve) and equipment shutoff valve

from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe where equipment shutoff valve was connected.

3. Pressurize supply piping system by either using compressed air or opening gas supply tank valve.

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. If

bubbles form, there may be a leak.

5. Correct all leaks immediately.

6. Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1. Close equipment shutoff valve (See Fig. 16).

2. Pressure supply piping system by either using compressed air or opening gas supply tank valve.

3. Check all joints from gas meter to equipment shutoff valve (See Fig. 17.1 or 17.2). Apply mixture of

liquid soap and water to gas joints. If bubbles form, there may be a leak.

4. Correct all leaks immediately.

Pressure Testing Heater Gas Connections

1. Open equipment shutoff valve (See Fig. 16).

2. Open gas supply tank valve.

3. Make sure control knob of heater is in the OFF position.

4. Check all joints from equipment shutoff valve to control valve

(See Fig. 17.1 or 17.2). Apply mixture of liquid soap and water to gas joints.

If bubbles form, there may be a leak.

5. Light heater (see Operation, page 24).

Fig. 16 - Equipment Shutoff Valve

Check all other internal joints for leaks.

6. Turn off heater (see "To Turn Off Gas to Appliance," page 24).

Fig. 17.1 - Checking Gas Joints

(Propane/LP Only)

19

Fig. 17.2 - Checking Gas Joints

(Natural Gas Only)

INSTALLATION

In compliance with ANSI Z21.60•CGA2.26 and National Fuel Gas Code, Section 6.

BEFORE INSTALLING THE APPLIANCE

- Turn off gas supply to fireplace or firebox.

- Clean fireplace floor and chimney before installing log set. Seal any ash. Clean out doors to protect

the unit from down drafts.

MOUNTING ASSEMBLY PROCEDURE

- Place grate/burner assembly into firebox with the front pan facing forward.

- Drill two (2) 5/32" diameter holes approximately 1" deep.

- Anchor the front pan to the floor using the (2) Concrete Attachment Screws (Not Included).

(See Fig. 18).

- Proper installation of the grate is essential to prevent any movement of the gas logs and

controls during operation.

1/4 x 3/4 Concrete

Hex Head Flanged

Concrete Screw

Mark Location using Log Set and Drill Hole in Floor of

Fireplace Approx. 1" deep to Accept Concrete Screw.

(Both Sides)

Fig. 18

20

ASSEMBLING LOGS

WARNING:

Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

WARNING: All previously applied loose material must be removed prior to reapplication

CAUTION:

After installation and peridically thereafter, check to ensure that no yellow flame comes in contact with any log. With the heater set to High, check to see if yellow flames contact any log. If so, reposition logs according to the log installation instructions in this manual. Yellow flames contacting logs will create soot.

Provided Logs: 8

It is very important to install the logs exactly as instructed. Do not modify logs; use only logs supplied with heater. Each log is marked with a number, and this number will help you identify each log during installation.

1 2 3 4 5 6 7 8

Fig. 19 - Installing Log #1 Fig. 20 - Installing Log #2-3 Fig. 21 - Installing Log #4

1

2

3

4

1. Insert log #1 onto pins in middle grate base.

2. Place log #2 & #3 onto the front grate. Make sure the recessed areas on the log match up with the

3. Place log #4 so it is resting in the top left recessed areas of logs #1 & #2.

grate, and the inside end of each log is centered on grate.

Fig. 22 - Installing Log #5 Fig. 23 - Installing Log #6 Fig. 24 - Installing Log #7-8

7 8

5 6

4. Place log #5 so it is resting in the top right recessed areas of logs #1

& #4, and just touching the top right of log #2.

5. Place log #6 so it is resting in the crotch of log #4 and so the crotch of log #6 is in between log #5.

21

6. Log #6 & #7 are optional

- decorative logs that can be placed anywhere NOT on the unit, but on the floor of the firebox. It is recommended to place them as illustrated.

INSTALLATION

EMBER FLAKE INSTALLATION

NOTE: This is an optional accessory, and is not required for operation of the heater.

WARNING: Apply loose material per instruction manual. DO NOT apply extra material or material not supplied with the heater. Replace only with Pleasant Hearth brand Ember

Flakes (Model #GEF100).

WARNING: All previously applied loose material must be removed prior to reapplication.

WARNING:

This appliance includes a material to simulate glowing embers when the unit is in operation. Positioning this material is critical to the safe operation of the unit and directions for the size and placement must be followed explicitly.

1. Open the small bag and remove all of the ember material.

2. Tear the material into flat triangular shapes approximately ½” on each side.

3. Carefully place the shapes on the horizontal burner tube as depicted in Fig. 25.

4. Make sure the Ember Flakes do not cover the Burner Port Holes.

5. Flames emanating from the Burner Port Holes will cause the ember Flake edges to glow when the unit is in operation.

A

Ember Burner Tube

Ember Flakes

Burner Port Holes

Ember Flake Positioning

Detail A

Fig. 25

22

OPERATION

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by the electronic ignitor. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Forced or attempted repair may result in fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

BATTERY INSTRUCTIONS

• Batteries are included.

• Remove batteries when depleted.

• Install/replace the batteries according to the type and quantity stated in table below.

• Do not mix old and new batteries. New batteries should be the same brand for best results.

• Be sure to observe proper polarity (+/-) when installing or replacing the batteries. Damage due to

improper battery installation may void the warranty on the product.

• For remote control systems, maximize battery life by turning off the receiver when it is not in use.

• For long periods of non-operation, remove batteries from all components for safety.

Component Type of Battery Battery Qty.

Ignitor AAA 1

*Note: Quantity depends on model of remote control.

23

OPERATION

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information as noted above.

2. Set receiver switch to “ON” position (See Fig. 26).

• When used as a vented decorative appliance, use of the thermostat

function is prohibited, operate manually only.

3. Turn control knob clockwise to the “OFF” position (See Fig. 26).

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including

near the floor. If you smell gas, STOP! Follow “B” in the safety information

as noted above. If you don’t smell gas, go to the next step.

5. Push in slightly and turn control knob counterclockwise to the

“PILOT” position (See Fig. 26). Depress control knob.

6. With control knob depressed, push down on the ignitor button until the

pilot lights. The pilot's location is behind log #3 near the center of the

burner. (See Fig. 27).

7. Keep control knob depressed for (30) seconds after pilot lights. Release

control knob.

OFF REMOTE

LEARN

ON

Fig. 26 - Receiver

& Control Knob

Note: Small Flame on

LP ODS Pilot

• If the control knob does not pop up when released, stop and immediately call a qualified service technician or gas supplier.

• If pilot goes out repeat steps 3 through 7. Wait (1) minute before attempting to light pilot again. If after several tries the pilot still goes out, turn the gas control knob clockwise to the “OFF” position and call a qualified service technician.

8. Turn control knob counterclockwise to the “ON” position.

9. To use the included thermostatic remote control, set receiver switch to

the “REMOTE” position (See Fig. 28). Press the ON button to turn on the

remote to ignite the main burner. Refer to the remote control instruction

manual on the next page for “MODE” and “SET” functions.

Fig. 27 - Pilot

ON

OFF

MODE

SET

Fig. 28 - Remote

WARNING: The fireplace screen must be in place while the appliance is in operation.

WARNING: Any glass doors shall be completely opened while appliance is in operation.

TO TURN OFF GAS TO APPLIANCE

1. Set thermostat to the lowest setting.

2. Press the OFF button on the remote control.

3. Push in slightly and turn control knob clockwise to the “OFF” position.

24

REMOTE CONTROL OPERATION

MULIT-FUNCTION WIRELESS REMOTE CONTROL SYSTEM

FOR OPERATING A LATCHING SOLENOID VALVE, MANUALLY OR WITH A THERMOSTAT FUCTION

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT

ATTEMPT TO INSTALL OR OPERATE

INTRODUCTION

This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating appliances. The system is operated manually from the transmitter. The system operates on radio frequencies (RF) within a 20-feet range using non-directional signals. The system operates on one of 1,048,576 security codes that are programmed into the transmitter at the factory; the remote receiver's code must be matched to that of the transmitter prior to initial use.

Review COMMUNICATION SAFETY under GENERAL INFORMATION section. This safety feature shuts down the appliance when a potentially unsafe condition exists.

TRANSMITTER

ON

OFF

MODE

SET

FRONT

ON

BATTERY

COMPARTMENT

BACK

1

This remote control SYSTEM offers the user a battery-operated remote control to power a latching solenoid such as those used with gas valves used in some heater rated gas logs, gas fireplaces and other gas heating appliances.

The solenoid circuit uses the battery power from the receiver to operate a solenoid. The circuit has reversing polarity software which reverses the positive

(+) and negative (-) output of the receiver's battery power to drive a latching solenoid ON/OFF. The SYSTEM is controlled by the remote transmitter.

The transmitter operates on a (2) 1.5V AAA batteries.

It is recommended that ALKALINE batteries always be used for longer battery life and maximum operational performance.

Before using the transmitter, install the (2) AAA transmitter batteries into the battery compartment. (Use caution that batteries are installed in the proper direction)

KEY SETTINGS

OFF

2

MODE

ON - Operates unit to on position, Manually operated solenoid ON.

OFF - Operates unit to off position, Manually operated solenoid OFF.

MODE - Changes unit from manual mode to thermo mode.

SET - Sets temperature in thermo mode.

SET

3

4

25

REMOTE CONTROL OPERATION

LCD - Liquid Crystal Display

4

1

ROOM

SET

TEMP

2

3

5

6

1. DISPLAY

2.

0

F OR

0

C

3. FLAME

4. ROOM

5. TEMP

6. SET

temperature in

Indicates CURRENT room temperature .

Indicates degrees Fahrenheit or Celsius.

Indicates burner/valve in operation.

Indicates remote is in THERMO operation.

Appears during manual operation.

Appears during time the of setting the desired

the thermo operation.

TEMP

SETTING

0

F /

0

C SCALE

The factory setting for temperature is first

0

F. To change this setting to

0

C,

Press the ON key and the OFF key on the transmitter at the same time this will change from

0 C

. Follow this same procedure to change from

0

C back to

0

0 F

to

F.

MANUAL FUNCTION

SCREEN WHILE

DEPRESSING ON

KEY

TEMP

SCREEN AFTER 3

SECOND DEFAULT

To operate the system in the manual “MODE” do the following.

ON OPERATION

Press the ON key the appliance flame will come on. During this time the

LCD screen will show ON, after 3 seconds the LCD screen will default to display room temperature and the word TEMP will show. (Flame icon

wil appear on LCD screen in manual on mode)

OFF OPERATION

Press the OFF key the appliance flame will shut off. During this time the

LCD screen will show OF, after 3 seconds the LCD screen will default to display room temperature and the word TEMP will show.

SCREEN WHILE

DEPRESSING OFF

KEY

TEMP

SCREEN AFTER 3

SECOND DEFAULT

SET TEMP

THERMO SET

ROOM

TEMP

THERMO MODE

THERMOSTAT FUNCTION

SETTING DESIRED ROOM TEMPERATURE

When used as a vented decorative appliance, use of the thermostat function is prohibited, operate manually only.

This remote control system can be thermostatically controlled when the transmitter is in the THERMO mode (The word ROOM must be

displayed on the screen). To set the THERMO MODE and DESIRED room temperature,

Press the MODE key until the LCD screen shows the word ROOM, then the remote is in the thermostatic mode.

Press and hold the SET key until the desired set temperature is reached. (By pressing and holding the set key the LCD screen set

26

REMOTE CONTROL OPERATION

for 3 seconds and the LCD screen will flash the set temperature for 3 seconds, then the LCD screen will default to display the room temperature.

TO CHANGE THE SET TEMPERATURE

ROOM TEMP ROOM TEMP

Press and hold the SET key until the desired set temperature is reached. (By pressing and holding the set key the LCD screen set numbers will increase from 45

0

to 99

0

then restart over at 45

0

) Next release the SET key. The LCD screen will display the set temperature for 3 seconds, then will flash the set temperature for 3 seconds, then the

LCD screen will default to display the room temperature.

THERMO ON

THERMO OFF

Press the MODE key to disengage the thermo mode. The word ROOM on the LCD screen will not show when the thermo is not in operation.

NOTE: The highest SET temperature is 99 and the lowest temperature is (45

0

0

Fahrenheit (32

Fahrenheit (6

0

Celsius)

0

Celsius)

OPERATIONAL NOTES:

The Thermo Feature on the transmitter operates the appliance whenever the ROOM TEMPERATURE varies a certain number of degrees from the SET TEMPERATURE. This variation is called the “SWING” or TEMPERATURE DIFFERENTIAL. The normal operating cycle of an appliance may be 2-4 times per hour depending on how well the room or home is insulated from the cold or drafts.

The factory setting for the “swing number” is 2. This represents a temperature variation of +/- 2 and ROOM temperature, which determines when the fireplace will be activated.

0

F (1

0

C) between SET temperature

The transmitter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed the word ON or OF will appear on the LCD screen to show while the signal is being sent. Upon initial use, there may be a delay of three seconds before the remote receiver will respond to the transmitter. This is part of the system's design.

POWER SETTING – CON 1001 TH

The electronics in the remote control system have the capability of "powering" two different types of DC-powered components. If any operational problems are noted, contact World Marketing of America, Inc.

The RECEIVER comes from the factory programmed to provide pulse DC voltage (5.5 VDC to 6.3 VDC) to a latching solenoid.

REMOTE RECEIVER

IMPORTANT

THE REMOTE RECEIVER SHOULD BE POSITIONED WHERE AMBIENT

TEMPERATURES DO NOT EXCEED 130° F.

The remote receiver (right) operates on (4) 1.5V AA-size batteries. It is recommended that ALKALINE batteries be used for longer battery life and maximum microprocessor performance. IMPORTANT: New or fully charged batteries are essential to proper operation of the remote receiver as a latching solenoid power consumption is substantially higher than standard remote control systems.

NOTE: The remote receiver will only respond to the transmitter when the 3-position slide button on the remote receiver is in the REMOTE position. The remote receiver houses the microprocessor that responds to commands from the transmitter to control system operation.

Learning

button

Slide

Switch

ON

REMOTE

OFF

Requires 4-AA 1.5V

alkaline batteries

Remote Receiver

Bat ter y c ove r sl ide s o n/o ff

27

REMOTE CONTROL OPERATION

FUNCTIONS:

With the slide switch in the REMOTE position, the system will only operate if the remote receiver receives commands from the transmitter.

Upon initial use or after an extended period of no use, the ON button may have to be pressed for up to three seconds before activating servo motor. If the system does not respond to the transmitter on initial use, see

LEARNING TRANSMITTER TO RECEIVER.

Receiver

Slide

Button

Remote Receiver

Wire terminals

LEARN

With the slide switch in the ON position you can manually turn ON the system.

With the slide in the OFF position, the system is OFF.

It is suggested that the slide switch be placed in the OFF position if you will be away from your home for an extended period of time.

OFF REMOTE ON

Placing the slide switch in the OFF position also functions as a safety "lock out" by both turning the system OFF and rendering the transmitter inoperative.

INSTALLATION INSTRUCTIONS

WARNING

DO NOT CONNECT REMOTE RECEIVER DIRECTLY TO 110-120VAC POWER. THIS WILL BURN

OUT THE RECEIVER. FOLLOW INSTRUCTIONS FROM MANUFACTURER OF GAS VALVE FOR

CORRECT WIRING PROCEDURES. IMPROPER INSTALLATION OF ELECTRIC COMPONENTS

CAN CAUSE DAMAGE TO GAS VALVE AND REMOTE RECEIVER.

INSTALLATION

The remote receiver can be mounted on or near the fireplace hearth. PROTECTION FROM EXTREME HEAT IS VERY IMPORTANT.

Like any piece of electronic equipment, the remote receiver should be kept away from temperatures exceeding 130º F inside the receiver case. Battery life is also significantly shortened if batteries are exposed to high temperatures.

HEARTH MOUNT

The remote receiver can be placed on the fireplace hearth or under the fireplace, behind the

Remote Receiver

Wire terminals control access panel. Position where the ambient temperature inside the receiver case does not exceed 130º F.

NOTE: Black Button is used on Hearth Mount Applications.

WIRING INSTRUCTIONS

Make sure the remote receiver switch is in the OFF position. For best results it is recommended that 18 gauge stranded wires should be used to make connections and no longer than 20-feet.

Pulse Connection

This CON1001 TH remote receiver is to be connected

Concentric Valve to a manual valve with a latching ON/OFF solenoid.

Connect two 18 gauge stranded or solid wires from the remote receiver terminals to the latching solenoid.

(See figure to the right)

Receiver

Slide

Button

OFF

REMOTE ON

LEARN

Red Wire

Black Wire

IMPORTANT NOTE: Operation of this control is dependent on which wire is attached to which terminal.

If operation of control does not correspond to operating buttons on transmitter, reverse wire installation at the receiver or at the control.

OFF REMOTE

LEARN

ON

Remote Receiver

NOTE: Up to 6.3 VDC of power is provided at the receiver terminal.

28

REMOTE CONTROL OPERATION

GENERAL INFORMATION

COMMUNICATION – SAFETY – TRANSMITTER – (C/S – TX)

This Kozy-World remote control has a COMMUNICATION –SAFETY function built into its software. It provides an extra margin of safety when the TRANSMITTER is out of the normal 20-foot operating range of the receiver.

The COMMUNICATION – SAFETY feature operates in the following manner, in all OPERATING MODES – ON/ ON THERMO.

At all times and in all OPERATING MODES, the transmitter sends an RF signal every fifteen (15) minutes, to the receiver, indicating that the transmitter is within the normal operating range of 20-feet. Should the receiver NOT receive a transmitter signal every 15 minutes, the IC software, in the RECEIVER, will begin a 2-HOUR (120-minute) countdown timing function. If during this 2-hour period, the receiver does not receive a signal from the transmitter, the receiver will shut down the appliance being controlled by the receiver.

The RECEIVER will then emit a series of rapid “beeps” for a period of 10 seconds. Then after 10 seconds of rapid beeping, the

RECEIVER will continue to emit a single “beep” every 4 seconds until a transmitter ON or MODE Button is pressed to reset the receiver. The intermittent 4-second beeping will go on for as long as the receiver’s batteries last which could be in excess of one year.

To “reset” the RECEIVER and operate the appliance, you must press the ON or MODE button on the transmitter. By turning the system to ON, the COMMUNICATION -SAFETY operation is overridden and the system will return to normal operation depending on the MODE selected at the transmitter. The COMMUNICATION – SAFETY feature will reactivate should the transmitter be taken out of the normal operating range or should the transmitter’s batteries fail or be removed.

CP (CHILDPROOF) FEATURE

This Kozy-World remote control includes a CHILDPROOF “LOCK-OUT” feature that allows the user to “LOCK-OUT” operation of the appliance, from the TRANSMITTER.

SETTING “LOCK-OUT” –(CP)

To activate the “LOCK-OUT” feature, press and hold the ON button and the MODE button at the same time for 5 seconds. The letters CP will appear in the TEMP frame on the LCD screen.

To disengage the “LOCK-OUT”, press and hold the ON button and the MODE button at the same time for 5 seconds and the letters

CP will disappear from the LCD screen and the transmitter will return to its normal operating condition.

To verify that transmitter is in the CP lock-out mode press any key and the LCD screen will show “CP”

NOTE: If the appliance is already operating in the ON or THERMO MODES, engaging the “LOCK-OUT” will not cancel the operating

MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANSMITTER. If in the auto modes, the THERMO operation will continue to operate normally. To totally “LOCK-OUT” the operation of the TRANSMITTER’S operating signals; the transmitter’s MODE must be set to OFF.

LEARNING TRANSMITTER TO RECEIVER

Each transmitter uses a unique security code. It will be necessary to press the LEARN button on the receiver to accept the transmitter security code upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the factory. In order for the receiver to accept the transmitter security code, be sure the slide button on the receiver is in the REMOTE position; the receiver will

not LEARN if the slide switch is in the ON or OFF position. The LEARN button in located on the front face of the receiver; inside the small hole labeled LEARN. Using a small screwdriver or end of a paperclip gently press and release the black LEARN button inside the hole. When you release the LEARN button the receiver will emit an audible “beep”. After the receiver emits the beep press the transmitter ANY button and release. The receiver will emit several beeps indicating that the transmitter’s code has been accepted into the receiver.

The microprocessor that controls the security code matching procedure is controlled by a timing function. If you are unsuccessful in matching the security code on the first attempt, wait 1 - 2 minutes before trying again--this delay allows the microprocessor to reset its timer circuitry--and try up to two or three more times.

29

REMOTE CONTROL OPERATION

TRANSMITTER WALL CLIP

The transmitter can be hung on a wall using the clip provided. If the clip is installed on a solid wood wall, drill 1/8" pilot holes and install with the screws provided. If it is installed on a plaster/wallboard wall, first drill two 1/4" holes into the wall. Then use a hammer to tap in the two plastic wall anchors flush with the wall; then install the screws provided.

BATTERY LIFE

WALL CLIP

BATTERY

COMPARTMENT

Life expectancy of the alkaline batteries in the CON1001-TH can be up to 12 months depending on use of the solenoid function.

Replace all batteries annually. When the transmitter no longer operates the remote receiver from a distance it did previously (i.e., the transmitter's range has decreased) or the remote receiver does not function at all, the batteries should be checked. It is important that the remote receiver batteries are fully charged, providing combined output voltage of at least 5.5volts. The transmitter should operate with as little as 2.5 volts battery power.

TROUBLE SHOOTING

If you encounter problems with your fireplace system, the problem may be the fireplace itself or it could be with the CON1001-TH remote system. Review the fireplace manufacturer's operation manual to make sure all connections are properly made. Then check the operation of the remote in the following manner:

Make sure the batteries are correctly installed in the RECEIVER. One reversed battery will keep receiver from operating properly.

Check battery in TRANSMITTER to ensure contacts are touching (+) and (-) ends of battery. Bend metal contacts in for tighter fit.

Be sure RECEIVER and TRANSMITTER is within 20 to 25-foot operating range.

Clear Codes: Memory in the receiver might be full if the learn button is pressed too many times. If this happens it will not allow any more codes to be learned and no audible beep will be heard. To clear memory, place the receiver slide switch into the REMOTE position. Press the learn button and release after 10 seconds. You should hear three (3) long audible beeps indicating all codes have cleared. You can now “learn” the transmitter to the receiver as described in the General Information Section.

Keep RECEIVER from temperatures exceeding 130° F. Battery life shortened when ambient temperatures are above 115° F.

If RECEIVER is installed in tightly enclosed metal surround, the operating distance will be shortened.

SPECIFICATIONS

BATTERIES: Transmitter (2) 1.5 volt AAA t bateries

Remote Receiver 6V - 4 ea. AA 1.5 Alkaline

FCC ID No.'s: transmitter - K9LSP1001TH; receiver - K9L330IRX

Operating Frequency: 303.8 MHZ

FCC REQUIREMENTS

Canadian IC ID No.'s: transmitter – 2439A-SP1001TH; receiver – 2439A-3301RX

NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY

UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S

AUTHORITY TO OPERATE THE EQUIPMENT.

30

OPERATION

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 30.

• turn heater off (see To Turn Off Gas to Appliance, page 24.

• see Troubleshooting, page 34.

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Fig. 29 - Correct Pilot Flame Pattern Fig. 30 - Incorrect Pilot Flame Pattern

LP LP

NG

Note: Small Flame on

LP ODS Pilot

NG

WARNING: If yellow tipping occurs, your heater could produce increased levels of carbon

monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this

page.

WARNING: Do not allow fans to blow directly into the heater. Avoid any drafts that alter burner

flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other acessory not approved for

use with this heater.

Notice: Do not mistake orange flames with yellow tipping. Dirt or other fine particles enter the heater and burn causing brief patches of orange flame.

31

CARE AND MAINTENANCE

BURNER FLAME PATTERN

Figure 31 shows a correct burner flame pattern. Figure 32 shows an incorrect burner flame pattern.

The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.

Note: When using the heater the first time, the flame will be orange for approximately one hour until the log cures.

If burner flame pattern is incorrect, as shown in Figure 32

• turn heater off (see To Turn Off Gas to Appliance, page 24).

• see Troubleshooting, page 34.

2-6 inches above logs

6-12 inches above logs

Fig. 31 - Correct/Normal Flame Pattern with short flames

Fig. 32 - Incorrect/Abnormal Flame

Pattern with tall flames

WARNING: Turn off heater and let cool before servicing.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater

clean. Inspect these areas of heater before each use. Have heater inspected yearly by a

qualified service person. Heater may need more frequent cleaning due to excessive lint

from carpeting, bedding material, pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting

and property damage.

BURNER ORIFICE HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt.

To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

FOR VENTED APPLICATIONS

Periodic examination and cleaning of the venting system and the solid fuel-burning fireplace, including frequency of such examination and cleaning, must be done by a qualified agency.

32

CARE AND MAINTENANCE

1. Shut off unit including pilot. Allow unit to cool for at least 30 minutes.

2. Inspect burner, pilot and primary air inlet holes on orifice holder for dust and dirt (See Fig. 33).

3. Blow air through the ports/slots and holes in the burner.

4. Check the orifice holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the orifice holder.

6. In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figures 34 or 35 depending on model). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner

Tube

Primary Air

Inlet Slot

Fig. 33 - Primary Air Inlet Slot on

Burner Tube

LP Pilot Air Inlet Hole

Fig. 34 - Pilot Inlet Air Hole

(Propane/LP Gas)

NG Pilot Air Inlet Hole

Fig. 35 - Pilot Inlet Air Hole

(Natural Gas)

LOG SET

• If you remove the log set for cleaning, refer to page 21, for placement instructions.

• Replace log set if broken or chipped (dime sized or larger).

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

33

TROUBLESHOOTING

• Shut off gas supply.

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

WARNING: Make sure that power is turned off before proceeding.

WARNING: Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

PROBLEM POSSIBLE CAUSE

When ignitor button is pressed in, there is no spark at ODS/ pilot.

When ignitor button is pressed in, there is a spark at ODS/ pilot but no ignition.

1. Ignitor electrode is

positioned wrong.

2. Ignitor electrode is broken.

3. Ignitor electrode is not

connected to ignitor cable.

4. Ignitor cable is pinched or wet.

5. Damaged ignitor cable.

6. Bad piezo ignitor.

7. Bad Battery.

1. Gas supply is turned off or

equipment shutoff valve is

closed.

2. Control knob not fully

pressed in while pressing

ignitor button.

3. Air in gas lines when

installed.

4. ODS / pilot is clogged.

5. Gas regulator setting is not correct.

6. Control knob not in PILOT position.

7. Depleted gas supply (propane).

CORRECTIVE ACTION

1. Replace electrode.

2. Replace electrode.

3. Replace ignitor cable

4. Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry.

5. Replace ignitor cable.

6. Replace piezo ignitor.

7. Check Battery and replace if needed.

1. Turn on gas supply or open equipment shutoff valve.

2. Fully press in control knob while

pressing ignitor button.

3. Continue holding down control knob.

Repeat igniting operation until air is

removed.

4. Clean ODS/pilot (see Care and

Maintenance, page 32 & 33) or replace

ODS/pilot assembly.

5. Replace gas regulator.

6. Turn control knob to PILOT position.

7. Contact local propane/LP gas company.

34

TROUBLESHOOTING

PROBLEM

ODS/pilot lights but flame goes out when control knob is released.

POSSIBLE CAUSE

1. Control knob is not fully

pressed in.

2. Control knob is not pressed

in long enough.

3. Equipment shutoff valve is

not fully open.

4. Thermocouple connection is

loose.

5. Thermocouple damaged.

6. Control valve damaged.

Burner(s) does not light afterODS/pilot is lit.

1. Burner orifice is clogged.

2. Burner orifice diameter is

too small.

3. Inlet gas pressure is too low.

Burner(s) does not light afterODS/pilot is lit. (Heater is set up for NG.)

1. Inlet gas pressure is too high.

Delayed ignition of burner(s).

1. Manifold pressure is too low.

2. Burner orifice is clogged.

Burner backfiring during combustion.

High yellow flame during burner combustion

Gas odor during combustion.

1. Burner orifice is clogged or

damaged.

2. Burner is damaged.

3. Gas regulator is damaged.

1. Not enough air.

2. Gas regulator is defective.

3. Inlet gas pressure is too low.

1. Foreign matter between control valve and burner.

2. Gas leak. (See Warning

Statement at top of page 34).

Heater produces a clicking/ticking noise just after burner is lit or shut off.

1. Metal is expanding while

heating or contracting

while cooling.

35

CORRECTIVE ACTION

1. Press in control knob fully.

2. After ODS/pilot lights, keep control

knob pressed in 30 seconds.

3. Fully open equipment shutoff valve.

4. Hand tighten until snug, and then

tighten ¼ turn more.

5. Replace thermocouple.

6. Contact customer service.

1. Clean burner orifice (see Care and

Maintenance, page 32 & 33 or contact

customer service.

2. Contact customer service.

3. Contact your gas supplier.

1. Contact your gas supplier.

1. Contact your gas supplier.

2. Clean burner (see Care and Maintenance, page 32 & 33) or contact customer service.

1. Clean burner orifice (see Care and

Maintenance, page 32 & 33 or contact

customer service.

2. Contact dealer or customer service.

3. Replace gas regulator.

1. Check burner for dirt and debris. If found, clean burner (see Care and Maintenance, page 32 & 33).

2. Replace gas regulator.

3. Contact your gas supplier.

1. Take apart gas tubing and remove foreign matter.

2. Locate and correct all leaks (see “Checking Gas Connections,” page 19).

1. This is common with most heaters. If noise is excessive, contact qualified

service technician.

TROUBLESHOOTING

PROBLEM

White powder residue forming within burner box or on adjacent walls or furniture.

Heater produces unwanted odors.

POSSIBLE CAUSE

1. When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue.

1. Heater is burning vapors

from paint, hair spray, glues, etc. See IMPORTANT statement, page 34.

2. Gas leak. See Warning

Statement, page 34.

3. Low fuel supply.

CORRECTIVE ACTION

1. Turn heater off when using furniture

polish, wax, carpet cleaner or similar products.

1. Ventilate room. Stop using odor

causing products while heater is

running.

2. Locate and correct all leaks (see

“Checking Gas Connections,” page 19).

3. Refill supply tank (Propane /LP models).

Heater shuts off in use (ODS operates).

1. Not enough fresh air is

available.

2. Low line pressure.

3. ODS/pilot is partially

clogged.

Gas odor exists even when control knob is in OFF position.

1. Gas leak. See Warning

Statement at top of page 34.

2. Control valve is

defective.

1. Open window and/or door for

ventilation.

2. Contact local gas supplier.

3. Clean ODS/pilot (see Care and

Maintenance, page 32 & 33).

1. Locate and correct all leaks (see

“Checking Gas Connections”, page 19).

2. Contact customer service.

1. Not enough combustion/

ventilation air.

1. Refer to “Air for Combustion and

Ventilation” requirements, page 8.

Moisture/condensation noticed on windows.

Slight smoke or odor during initial operation

Heater produces a whistling noise when burner is lit.

1. Residues from

manufacturing process.

1. Turning control knob to high (5) position when burner is cold.

2. Air in gas line.

3. Air passageways on

heater are blocked.

4. Dirty or partially clogged

burner orifice.

1. Problem will stop after a few hours of operation.

1. Turn control knob to low (1) position and let warm up for a minute.

2. Operate burner until air is removed from line. Have gas line checked by local

propane/LP gas company.

3. Observe minimum installation

clearances (Fig. 5, 6, 7, 8, 9, page 13-14).

4. Clean burner (see Care and Maintenance, page 32 & 33) or contact customer service.

36

REPLACEMENT PARTS LIST

For replacement parts, call our Technical Service Department at 1-877-447-4768, 8:30 a.m. – 4:30 p.m.,

CST, Monday – Friday.

1-2

1-4

1-6

1-1

1-5

1-3

3

2

5

6

7

4

1-7

1-8

9

8

ITEM  NO.

DESCRIPTION QTY

7

8

5

6

1  -­‐  8

2

3

4

1

1  -­‐  1

1  -­‐  2

1  -­‐  3

1  -­‐  4

1  -­‐  5

1  -­‐  6

1  -­‐  7

Log  Set  (complete)

Log  1

Log  2

Log  3

Log  4

Log  5

Log  6

Log  7

Log  8

Grate

Grate  End  Cap

ODS  Pilot  -­‐  LP

ODS  Pilot  -­‐  NG

Selector  Knob

Regulator  

Ignitor  Module  

9

10

Ember  Bed

Remote  Receiver

1

1

11 Thermostat  Remote 1

*Item/version  not  shown  in  exploded  parts  diagram

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

VFL-­‐CY24DR                                                          

VFL-­‐HT24DR

PART  NO.

VFL-­‐CY30DR                                                                                    

VFL-­‐HT30DR

4UB2A

H-­‐010A

H-­‐010B

H-­‐0075

H-­‐0139

H-­‐0812

H-­‐0370

H-­‐0356

EXP-­‐4022B

EXP-­‐7010

EXP-­‐4044

EXP-­‐4519

80-­‐05-­‐102*

80-­‐05-­‐101*

4UB3A

H-­‐003A

H-­‐003B

H-­‐0075

H-­‐0139

H-­‐0812

H-­‐0370

H-­‐0356

800-­‐EB2410

EXP-­‐4509

800-­‐EB3010

EXP-­‐4509

EXP-­‐4046  (21500/246-­‐MR) EXP-­‐4046  (21500/246-­‐MR)

EXP-­‐4046LP  (21500/247-­‐MR) EXP-­‐4046LP  (21500/247-­‐MR)

EXP-­‐4022B

EXP-­‐7010

EXP-­‐4044

EXP-­‐4519

80-­‐05-­‐102*

80-­‐05-­‐101*

ACCESSORIES

NOTICE: All accessories may not be available for all models.

Glowing Ember Fibers - 20-8112 For all models. Material to simulate glowing embers when the unit is in operation. Creates a realistic glowing effect just like a real fire.

37

This limited warranty is extended to the original retail purchaser of this heater and warrants against any two

2 years two 2 years

33

38

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302

Tel: (877) 447-4768 www.ghpgroupinc.com

GHP Group, Inc.

6440 W Howard St

Niles, IL 60714-3302

34

39

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals