GAT Access 6350 Built-in Access Control Terminal

GAT Access 6350 Built-in Access Control Terminal
GAT Access 6350
Built-in Access Control Terminal
Application
The GAT Access 6350 is a stylish terminal for access control in leisure
facilities such as swimming pools, spas and gyms for mounting in turnstiles
or similar applications. Identification at the terminal is by contact-free
RFID data carrier (Radio Frequency Identification).
The clear interface guides the user through the various, well-structured
levels. The different versions (see order information) give technological
flexibility.
Function description
Order information
The GAT Access 6350 reads contact-free data carriers and checks and
Description
grants authorisations. The user holds the data carrier over the round scan
field and selects the required service via the acknowledge key. The integrated traffic light display and acoustic signal indicate authorisation.
Further functions:
•Activation of turnstiles, doors etc. via relay outputs
•Feedback inputs
•Illuminated, round scan field
•Secure data transmission between reader and data carrier
•Robust stainless-steel enclosure with safety glass
GAT Access 6350 B QT
PartNo.
728686
Built-in access control terminal with monochrome display
and contact-free reader for LEGIC® data carriers
GAT Access 6350 F QT
828687
Built-in access control terminal with monochrome display
and contact-free reader for MIFARETM data carriers
GAT Access 6350 ISO QT
767689
Built-in access control terminal with monochrome display
and contact-free reader for ISO 15693 data carriers
Accessories
Description
Manual GAT Access 6200/6350/6500 EN
PartNo.
169028
Installation, configuration and operating instructions in
english
www.gantner.com
Valid as from July 31rd 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6350--EN_12.indd • PartNo.: 679186
1
Technical data
Nominal voltage:
12/24 VDC
Permitted input voltage:
10 to 28 VDC
Signal inputs:
4 x optocouplers (configurable)
- Input voltage: 0 to 30 VDC
ULow < 2 VDC, UHigh > 6 VDC
- Input current: 4.5 mA
Aver. power consumption:
12 W
Data storage:
Internal flash memory for configuring
and booking memory, data preser­
vation min. 10 years
Signal outputs:
Data preservation approx. 12 h
(Gold-Cap)
4 x relays (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
Internal clock:
Connection terminals:
0.5 to 1.5 mm 2
Reader types:
See order information
Housing material:
Stainless-steel with safety glass
Control elements:
-Acknowledge key
-RFID reader
Dimensions (housing):
255 x 175 x 40.7 mm
(10 x 6.89 x 1.6 inch)
Display elements:
-Full graphics monochrome display
with white LED background lighting,
resolution 128 x 128 pixels,
visible area 65 x 65 mm
-RFID reader (illuminated)
-Acoustic signal
-Large integrated traffic light display
(green = access granted, red =
access denied)
Permitted ambient temperature: -10 to +55°C
Ethernet 10/100 Mbit/s and RS 485
Host interface:
Storage temperature:
-20 to +70°C
Relative humidity:
20 to 80%, non-condensing
Protection type:
IP 54 (front plate only if mounted
flush)
Protection class:
I
Weight:
1.3 kg
Environment class
based on VDS 2110:
II (conditions in indoor areas)
Dimensions
4
3
138 mm (5.43”)
1
1. Monochrome display
175 mm (6.89”)
2
139 mm (5.47”)
2
2. Traffic light display (red/green)
5
4. Illuminated, round scan field
5. Build-in frame with connection terminals
6. Earthing connection
239 mm (9.41”)
255 mm (10”)
153 mm (6.02”)
3. Acknowledge key
6
2.5 mm (0.1”)
40.7 mm (1.6”)
56.0 mm (2.2”)
6
Typical application
Turnstile
GAT Access 6350
Data carrier
Power supply
Network
2
Valid as from July 31rd 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6350--EN_12.indd • PartNo.: 679186
www.gantner.com
Mounting and installation instructions
The GAT Access 6350 is mounted in turnstiles or similar applications.
Required mounting space
Fixture is by means of four countersunk screws of 4 mm diameter (not
When mounting the device leave space for the running of the connecting
supplied) in the front plate. Recommended mounting height: Top edge of
cables, in particular the RJ 45 connector. For this purpose, a minimum
the device 1.3 m.
clearance of 100 mm from the front of the enclosure should be observed.
If this cannot be assured, angled RJ 45 connectors must be used!
Securing screws (4x)
e.g. turnstile
Cut-out for flush mounting
Securing screws (4x)
Earthing
153 mm (6.02”)
Strain relief via
cable ties
min
.1
00
mm
(3.
94
”)
Seal
220 mm (8.66”)
Instructions:
1. Leave 0.5 m (20“) excess cable for ease of mounting/maintenance.
2. Connect earth cable to cable lug on enclosure frame.
3. Connect remaining connection cables at the pluggable screw terminals.
4. Secure connecting cable with cable ties to the cable tie holders for
strain relief.
5. Adhere seal (included in the scope of supply) to the cut-out.
6. Mount device in the cut-out and secure with suitable screws.
7. Once mounting is complete, the protective film can be removed.
www.gantner.com
Valid as from July 31rd 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6350--EN_12.indd • PartNo.: 679186
3
Electrical connections
TCP/IP with external power supply
GAT Access 63xx
e.g. Turnstile
Motor control
M
Feedback contact
TCP/IP
B
A
GND
VOut+
Mains power
Power supply unit
e.g. GAT Power Supply SP014/1
RS 485 with power supply via interface converter
Relay outputs
For activation of devices like turnstiles, etc.. Every relay supports the
contacts NC (breaker contact) and NO (maker contact.
Optocoupler inputs
Inputs for status acquisition. For using the input a supply voltage must be
applied. This voltage can be taken from the terminal‘s supply or from an
external power source. Please observe the max. permitted input voltages
and currents (see technical data).
0V24
B
A
+24 VDC
RS 232/USB
to PC/server
COM
Mains power
Interface converter
ISK 200
Network
RS 485 bus connection or Ethernet.
Attention: The two interfaces must not be operated at the same time!
When using RS 485 bus connection only connect the signal lines A and B.
Do not use the COM terminal.
Power supply
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1 or via the interface converter ISK 200. The two screw terminals
“VIN +“ are directly connected with each other internally. The power input
is protected against reverse-polarity.
Recommended cables
Ethernet: min. CAT 5 (STP) for 100 MBit
RS 485: min. CAT 5 (STP), power supply via 2 wire pairs
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembly or dismantling.
4
Valid as from July 31rd 2013 • Technical data subject to modifications without notice!
DB_GAT-ACCESS6350--EN_12.indd • PartNo.: 679186
www.gantner.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising