Performance IP Cameras User Guide

Performance IP Cameras User Guide
Performance Series
IP Cameras
HED1PR3
HED3PR3
H4D3PRV3
H4D3PRV2
HBD1PR1
HBD3PR1
HBD3PR2
Software Configuration
Guide
Recommended
Find the latest version of this and other Performance Series IP camera
documents on the Honeywell Video website. Go to
http://www.honeywellvideo.com/products/cameras/ip/index.html to
find your camera and view/download the latest documentation.
Refer to the Honeywell Open Technology Alliance to learn more
about our open and integrated solutions (go to:
http://www.security.honeywell.com/hota/).
Document 800-21358 – Rev A – 10/2015
Revisions
Issue
Date
Revisions
A
10/2015
New document.
| 3
Cautions and Warnings
WARNING
Installation and servicing should be performed
only by qualified and experienced technicians to conform to all
local codes and to maintain your warranty.
WARNING To ensure compliance with electrical safety
standards this product is intended for use with a Listed Power
Adapter marked with “Limited Power Source”, “LPS”, on the unit,
output rated 12 V DC, minimum 0.7A, Tma=60°C or from Power
over Ethernet (PoE) provided by Listed Information Technology
Equipment meeting the IEEE 802.3af PoE standard.
The Ethernet connection is not intended to be connected to
exposed (outside plant) networks. Do not connect two power
sources to the camera at the same time.
CAUTION
Invisible LED radiation (850 nm). Avoid exposure to beam.
Regulatory Statements
FCC Compliance Statement
Information to the User: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
800-21358 - A - 10/2015
4 | Performance Series IP Camera Software Configuration Guide
used in accordance with the instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Note
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Canadian Compliance Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la Classe B est conforme à la norme NMB-003 du Canada.
Manufacturer’s Declaration of Conformance
The equipment supplied with this guide meets the provisions of the following European Union
council directives:
•
2014/30/EU for EMC
•
2001/95/EC for safety, and
•
2011/65/EU for RoHS compliance.
WARNING To comply with EN50130-4 requirements, a UPS
should be employed when powering the camera from 24 V AC.
www.honeywell.com/security
| 5
Waste Electrical and Electronic Equipment (WEEE)
Correct Disposal of this Product (applicable in the European Union and other
European countries with separate collection systems).
This product should be disposed of, at the end of its useful life, as per
applicable local laws, regulations, and procedures.
Safety Instructions
Before installing or operating the unit, read and follow all instructions. After
installation, retain the safety and operating instructions for future reference.
1.
HEED WARNINGS - Adhere to all warnings on the unit and in the operating instructions.
2.
INSTALLATION
•
Install in accordance with the manufacturer’s instructions.
•
Installation and servicing should be performed only by qualified and experienced
technicians to conform to all local codes and to maintain your warranty.
•
Any wall or ceiling mounting of the product should follow the manufacturer’s
instructions and use a mounting kit approved or recommended by the manufacturer.
3.
POWER SOURCES - This product should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of power supplied to your
facility, consult your product dealer or local power company.
4.
MOUNTING SYSTEM - Use only with a mounting system recommended by the
manufacturer, or sold with the product.
5.
ATTACHMENTS/ACCESSORIES - Do not use attachments/accessories not
recommended by the product manufacturer as they may result in the risk of fire, electric
shock, or injury to persons.
6.
CLEANING - Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for
cleaning.
7.
SERVICING - Do not attempt to service this unit yourself. Refer all servicing to qualified
service personnel.
8.
REPLACEMENT PARTS - When replacement parts are required, be sure the service
technician has used replacement parts specified by the manufacturer or have the same
characteristics as the original part. Unauthorized substitutions may result in fire, electric
shock or other hazards. Using replacement parts or accessories other than the original
manufacturers may invalidate the warranty.
800-21358 - A - 10/2015
6 | Performance Series IP Camera Software Configuration Guide
Warranty and Service
Subject to the terms and conditions listed on the Product warranty, during the warranty period
Honeywell will repair or replace, at its sole option, free of charge, any defective products
returned prepaid.
In the event you have a problem with any Honeywell product, please call Customer Service at
1.800.323.4576 for assistance or to request a Return Merchandise Authorization (RMA)
number.
Be sure to have the model number, serial number, and the nature of the problem available for
the technical service representative.
Prior authorization must be obtained for all returns, exchanges, or credits. Items shipped to
Honeywell without a clearly identified Return Merchandise Authorization (RMA) number
may be refused.
www.honeywell.com/security
Contents | 7
Contents
About This Document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Overview of Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Typographical Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . .
Camera Dimensions . . . . . . . . . . . . . . . . . . . . . . .
HED1PR3/HED3PR3 Ball Cameras . . . . . . . . . . . . .
HBD1PR1/HBD3PR1 Bullet Cameras . . . . . . . . . . . .
HBD3PR2 Bullet Camera . . . . . . . . . . . . . . . . . .
H4D3PRV2 Mini Dome Camera . . . . . . . . . . . . . . .
H4D3PRV3 Mini Dome Camera . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
19
19
20
21
21
22
23
24
25
2
Getting Started . . . . . . . . . . . . . . . . . . . . . . . .
Installing the ConfigTool IP Utility . . . . . . . . . . . . . . . .
Discovering Your Device on the Network . . . . . . . . . . . .
Assigning a New IP Address to Your Device. . . . . . . . . . .
Upgrading Your Device’s Firmware . . . . . . . . . . . . . . .
Opening a Web Client . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
27
27
28
28
29
31
3
Logging In and Viewing Live Video. . . . . . . . . . . . .
Logging In to the Camera via the Web Client . . . . . . . . .
Before You Begin . . . . . . . . . . . . . . . . . . . . .
Logging In to the Camera . . . . . . . . . . . . . . . . .
Installing the Browser Plug-In . . . . . . . . . . . . . . .
Using the Live View Interface. . . . . . . . . . . . . . . . . .
Video Encoder Settings . . . . . . . . . . . . . . . . . .
System Menus . . . . . . . . . . . . . . . . . . . . . . .
Live View Controls . . . . . . . . . . . . . . . . . . . . .
Live View Window Configuration . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
33
33
33
33
34
35
36
36
36
37
4
Playing Back Video (HBD3PR2/H4D3PRV2 only) . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of the Playback Interface . . . . . . . . . . . . .
Playing Back Recorded Video . . . . . . . . . . . . . . . . . .
Playback Controls . . . . . . . . . . . . . . . . . . . . . .
Playing a Recorded File from the Calendar . . . . . . . . .
Searching for a File by Recording Type. . . . . . . . . . .
Timeline Configuration. . . . . . . . . . . . . . . . . . . .
Using the Playback Assistant. . . . . . . . . . . . . . . . . . .
Zooming In and Out . . . . . . . . . . . . . . . . . . . . .
Taking a Snapshot. . . . . . . . . . . . . . . . . . . . . .
Creating a Video Clip . . . . . . . . . . . . . . . . . . . . . . .
Viewing Snapshots . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
39
39
40
40
40
41
43
43
43
43
43
44
44
800-21358 - A - 10/2015
8 | Performance Series IP Camera Software Configuration Guide
5
Configuring Camera Settings. . . . . . . . . . . . . . . . .
Configuring Camera Settings . . . . . . . . . . . . . . . . . .
Conditions . . . . . . . . . . . . . . . . . . . . . . . . . .
Profile Management . . . . . . . . . . . . . . . . . . . . .
Zoom and Focus. . . . . . . . . . . . . . . . . . . . . . .
Video Configuration . . . . . . . . . . . . . . . . . . . . .
Video Bit Stream . . . . . . . . . . . . . . . . . . . .
Snapshot. . . . . . . . . . . . . . . . . . . . . . . . . . .
Video Overlay . . . . . . . . . . . . . . . . . . . . . . . .
ROI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Path . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Network Settings . . . . . . . . . . . . . . . . . .
TCP/IP . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection. . . . . . . . . . . . . . . . . . . . . . . . . .
ONVIF . . . . . . . . . . . . . . . . . . . . . . . . . .
PPPoE . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DDNS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manually Configuring the DDNS . . . . . . . . . . . .
Using Honeywell DDNS to Configure DDNS . . . . . .
IP Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMTP (Email) . . . . . . . . . . . . . . . . . . . . . . . .
UPnP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bonjour . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multicast . . . . . . . . . . . . . . . . . . . . . . . . . . .
IEEE802.1X . . . . . . . . . . . . . . . . . . . . . . . . .
QoS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Storage Settings . . . . . . . . . . . . . . . . . .
Recording Schedule and Snapshot Schedule . . . . . . .
Recording Schedule Color Codes: . . . . . . . . . . .
Setting Holidays . . . . . . . . . . . . . . . . . . . .
Destination . . . . . . . . . . . . . . . . . . . . . . . . . .
Path . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local . . . . . . . . . . . . . . . . . . . . . . . . . .
FTP . . . . . . . . . . . . . . . . . . . . . . . . . . .
NAS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Record Control. . . . . . . . . . . . . . . . . . . . . . . .
Configuring System Settings . . . . . . . . . . . . . . . . . . .
General System Setup. . . . . . . . . . . . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . .
Date and Time . . . . . . . . . . . . . . . . . . . . .
Account Setup . . . . . . . . . . . . . . . . . . . . . . . .
User Name . . . . . . . . . . . . . . . . . . . . . . .
Group . . . . . . . . . . . . . . . . . . . . . . . . . .
Restoring Default Settings . . . . . . . . . . . . . . . . . .
Import/Export . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Maintenance . . . . . . . . . . . . . . . . . . .
Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . .
Viewing System Information . . . . . . . . . . . . . . . . . . .
Version . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Online User . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
47
47
47
51
52
53
53
55
56
56
57
58
58
60
61
61
62
62
63
63
65
66
67
67
68
69
70
70
70
70
71
71
72
72
74
74
75
75
75
76
76
77
79
80
81
81
82
82
82
83
83
6
Configuring Events and Alarms . . . . . . . . . . . . . . .
Configuring Events . . . . . . . . . . . . . . . . . . . . . . . .
Configuring for Motion Detection . . . . . . . . . . . . . .
Video Motion Detection . . . . . . . . . . . . . . . . .
Configuring for Camera Tampering . . . . . . . . . . . . .
Configuring for Abnormalities . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
85
85
85
85
88
89
www.honeywell.com/security
Contents | 9
Configuring for Micro SD Card Abnormalities . . . . . . . . . . . . . . . . . . . . . . . .
Configuring for Network Abnormalities Such as Network Disconnections and IP Conflicts
Configuring for Illegal Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
89
91
91
92
Appendix A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Embedded NVR Integration Capacity Matrix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Appendix B Camera Specifications . . . . . . . . . . . .
HED1PR3/HED3PR3 Ball Cameras . . . . . . . . . . . .
HBD1PR1/HBD3PR1/HBD3PR2 Bullet Cameras . . . . .
H4D3PRV2/H4D3PRV3 Mini Dome Cameras . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
. . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
99
99
101
103
800-21358 - A - 10/2015
10 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
Figures | 11
Figures
Figure 1-1
HED1PR3/HED3PR3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 1-2
HED1PR3/HED3PR3 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Figure 1-3
HBD1PR1/HBD3PR1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 1-4
HBD1PR1/HBD3PR1 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 1-5
HBD3PR2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 1-6
HBD3PR2 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Figure 1-7
H4D3PRV2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 1-8
H4D3PRV2 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Figure 1-9
H4D3PRV3 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 1-10
H4D3PRV3 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 2-1
Log In to a Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 2-2
Network Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 2-3
Upgrade Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Figure 2-4
Select Batch Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 2-5
Batch Mode Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 2-6
Batch Upgrade Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 3-1
Login Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-2
First-time Login Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 3-3
File Download Security Warning Message for the Plug-in . . . . . . . . . . . . . . . . . . . . 34
Figure 3-4
Internet Explorer - Security Warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-5
Live View Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 3-6
Video Encoder Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 3-7
System Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 3-8
Live View Window Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 3-9
Live View Window Configuration Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 4-1
Playback Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 4-2
Playback Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 4-3
Playback Calendar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 4-4
Recording Timeline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 4-5
Playback File Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 4-6
Recording Type Filter in Live View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 4-7
Playback Timeline Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 4-8
Clip Function Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 4-9
Snapshot Playback Control Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 4-10
List of Snapshots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
800-21358 - A - 10/2015
12 | Performance Series IP Camera Software Configuration Guide
Figure 5-1
Camera Setup Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 5-2
Profile Management Tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Figure 5-3
Motorized Zoom and Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Figure 5-4
Video Bit Stream Configuration Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Figure 5-5
Snapshot Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 5-6
Video Overlay Configuration Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 5-7
ROI Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 5-8
Storage Path Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 5-9
TCP/IP Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Figure 5-10
Connection Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Figure 5-11
PPPoE Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Figure 5-12
DDNS Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Figure 5-13
Using Honeywell DDNS to Configure DDNS . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Figure 5-14
IP Filter Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Figure 5-15
SMTP Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Figure 5-16
UPnP Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Figure 5-17
Bonjour Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Figure 5-18
Multicast Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Figure 5-19
802.1X Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 5-20
QoS Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Figure 5-21
Recording Schedule Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Figure 5-22
Holiday Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 5-23
Path Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Figure 5-24
Local Storage Configuration Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Figure 5-25
FTP Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Figure 5-26
NAS Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 5-27
Record Control Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Figure 5-28
General System Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Figure 5-29
Date and Time Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Figure 5-30
Username Configuration Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Figure 5-31
Add User Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 5-32
Modifying User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Figure 5-33
Group Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 5-34
Add Group Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Figure 5-35
Modify Group Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 5-36
Default Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Figure 5-37
Import/Export Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 5-38
Auto Maintain Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Figure 5-39
Upgrade Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Figure 5-40
Version Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Figure 5-41
Log Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Figure 5-42
Online User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Figure 6-1
Motion Detection - Video Detection Configuration Interface . . . . . . . . . . . . . . . . . . . 85
Figure 6-2
Configuring the Working Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Figure 6-3
Configuring the Motion Detection Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
www.honeywell.com/security
Figures | 13
Figure 6-4
Tampering Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Figure 6-5
Tampering Working Period Configuration Interface. . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 6-6
No SD Card Warning Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Figure 6-7
SD Card Error Warning Configuration Interface. . . . . . . . . . . . . . . . . . . . . . . . . . 90
Figure 6-8
Capacity Warning Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Figure 6-9
Dicsonnection Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 6-10
IP Conflict Configuration Interfacet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
Figure 6-11
Illegal Access Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Figure 6-12
Alarm Configuration Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
800-21358 - A - 10/2015
14 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
Tables | 15
Tables
Table 3-1
Video Encoder Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 3-2
Live View Window Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Table 3-3
Live View Window Configuration Tools. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 4-1
Playback Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Table 5-1
Camera Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Table 5-2
Zoom and Focus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Table 5-3
Video Bit Stream Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Table 5-4
Snapshot Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Table 5-5
Video Overlay Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Table 5-6
ROI Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Table 5-7
TCI/IP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Table 5-8
Connection Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 5-9
DDNS Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table 5-10
Honeywell DDNS Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table 5-11
SMTP (Email) Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table 5-12
Multicast Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Table 5-13
802.1X Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 5-14
QoS Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Table 5-15
Path Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Table 5-16
FTP Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Table 5-17
NAS Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 5-18
Record Control Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Table 5-19
General System Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Table 5-20
Date and Time Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Table 5-21
Import/Export Configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Table 5-22
Log Interface Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Table 6-1
Video Motion Detection - Video Detection Configurations . . . . . . . . . . . . . . . . . . . . . 86
Table 6-2
Motion Detection Area Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Table 6-3
Tampering Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Table 6-4
Alarm Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
Table A-1
Embedded NVR Integration Matrix - Maximum Frame Rate and Resolution . . . . . . . . . . . 96
Table B-1
HED1PR3/HED3PR3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Table B-2
HBD1PR1/HBD3PR1/HBD3PR2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Table B-3
H4D3PRV2/H4D3PRV3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
800-21358 - A - 10/2015
16 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
| 17
About This Document
This document provides instructions for accessing, configuring, and operating the Performance
Series IP cameras. This document is intended for system installers, administrators, and
operators.
Overview of Contents
This document contains the following chapters and appendixes:
•
Chapter 1, Introduction, provides an overview of the main features of the Performance
Series IP cameras.
•
Chapter 2, Getting Started, describes how to install the Config Tool to access the camera
remotely from a web browser. It also describes how to update your camera’s firmware.
•
Chapter 3, Logging In and Viewing Live Video, describes how to log in to a camera and the
Live View interface.
•
Chapter 4, Playing Back Video (HBD3PR2/H4D3PRV2 only), describes how to search for
recorded video and snapshots, and how to export them.
•
Chapter 5, Configuring Camera Settings, describes all configurations, including camera
configurations, network configurations, storage configurations.
•
Chapter 6, Configuring Events and Alarms, shows how to set up notifications for alarm
inputs, motion detection, and network failure events.
•
Appendix A, Troubleshooting, lists common problems and solutions.
•
Appendix B, Camera Specifications, lists the specifications of the Performance Series IP
cameras.
800-21358 - A - 10/2015
18 | Performance Series IP Camera Software Configuration Guide
Typographical Conventions
This document uses the following typographical conventions:
Font
What it represents
Example
Helvetica Narrow
Keys on the keyboard
Press Ctrl+C
Lucida
Values of editable fields that are mentioned in the
The Time from field can be set to
body text of the document for reference purposes,
Hours:Minute:Seconds.
but do not need to be entered as part of a procedure
Text strings displayed on the screen
Swiss721 BT Bold Words or characters that you must type. The word
“enter” is used if you must type text and then press
the Enter or Return key.
Italic
The message Valid displays.
Enter the password.
Menu titles and other items you select
Double-click Open from the File menu.
Buttons you click to perform actions
Click Exit to close the program.
Placeholders: words that vary depending on the
situation
Enter your user name.
Cross-reference to external source
Cross-reference within document
Refer to the System Administrator Guide.
See Chapter 2, Installation.
www.honeywell.com/security
1
Introduction
1
This chapter contains the following sections:
•
Overview, page 19
•
Key Features, page 20
•
Camera Dimensions, page 21
Overview
Honeywell’s Performance Series IP cameras integrate traditional camera and network video
technology, combining video data collection and transmission. These flexible, fully featured
cameras are the ideal choice for a wide range of indoor and outdoor surveillance applications.
Plug-and-play compatible with Honeywell 4/8/16-channel Performance Series Embedded
NVRs, the cameras offer 1.3 or 3 megapixel resolution at up to 30 frames per second and use
H.264 video compression technology to save bandwidth and storage while ensuring maximum
video quality. All of the cameras are True Day/Night with intelligent IR capability, providing up to
100 ft (30 m) of illumination in low-light and nighttime scenes.
Each camera comes with configurable motion detection and camera tamper detection and
supports up to 4 user-defined privacy mask areas. In addition to a 12 V DC adapter, all of the
cameras support Power over Ethernet (PoE), eliminating the need for a separate power supply
and associated wiring. Select models also support local video storage on microSDHC cards (up
to 128 GB) when network service is interrupted.
You can monitor Performance Series IP cameras from anywhere, at any time, using the free
HonView Touch mobile app for both Apple and Android smartphones and tablets.
800-21358 - A - 10/2015
20 | Performance Series IP Camera Software Configuration Guide
Key Features
Key features of the Performance Series IP cameras include the following:
Camera
•
•
•
•
•
•
Storage
•
•
•
Network Monitoring
•
•
•
•
Day/Night mode auto-switch
Picture parameter setup, such as electronic shutter
and gain
Motion detection
Backlight compensation
Video watermark function to prevent modification
IR night vision
Central server backup (configure in Alarm or
Schedule settings)
Recording over Internet, files stored on client PC
Network storage (FTP)
One-channel video data transmission to a network
terminal and decoding
Delay time less than 270 ms (network bandwidth
support required)
Up to 20 connections
Compatible with the following network protocols:
IPv4/IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP,
IGMP, RTSP, RTP, SMTP, NTP, DHCP, DNS, PPPoE,
DDNS, FTP, IP Filter, QoS
Network Management
•
•
Camera configuration and management via Ethernet
Device management via Internet or client PC
User Management
•
•
•
Each user belongs to specific group
Different user rights for each group
User rights cannot exceed group rights
System Management
•
•
Log function
System resource information and running real-time
status display
www.honeywell.com/security
Introduction | 21
Camera Dimensions
This section displays the dimensions and main components/connectors of each
Performance Series IP camera.
HED1PR3/HED3PR3 Ball Cameras
Figure 1-1
HED1PR3/HED3PR3 Dimensions
Figure 1-2
HED1PR3/HED3PR3 Components
1
2
3
4
5
1.
Lens
2.
Camera module
3.
Camera enclosure
4.
LAN connector
5.
12 V DC connector
800-21358 - A - 10/2015
22 | Performance Series IP Camera Software Configuration Guide
HBD1PR1/HBD3PR1 Bullet Cameras
Figure 1-3
HBD1PR1/HBD3PR1 Dimensions
Figure 1-4
HBD1PR1/HBD3PR1 Connections
1
2
www.honeywell.com/security
1.
LAN connector
2.
12 V DC connector
Introduction | 23
HBD3PR2 Bullet Camera
Figure 1-5
HBD3PR2 Dimensions
Figure 1-6
HBD3PR2 Connections
1
2
1.
LAN connector
2.
12 V DC connector
800-21358 - A - 10/2015
24 | Performance Series IP Camera Software Configuration Guide
H4D3PRV2 Mini Dome Camera
Figure 1-7
H4D3PRV2 Dimensions
Figure 1-8
H4D3PRV2 Components
1
2
3
4
www.honeywell.com/security
1.
Camera module
2.
Camera enclosure
3.
LAN connector
4.
12 V DC connector
Introduction | 25
H4D3PRV3 Mini Dome Camera
Figure 1-9
H4D3PRV3 Dimensions
Figure 1-10
H4D3PRV3 Components
1
2
3
4
1.
Camera module
2.
Camera enclosure
3.
LAN connector
4.
12 V DC connector
800-21358 - A - 10/2015
26 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
2
Getting Started
2
This chapter contains the following sections:
•
Installing the ConfigTool IP Utility, page 27
•
Discovering Your Device on the Network, page 28
•
Assigning a New IP Address to Your Device, page 28
•
Upgrading Your Device’s Firmware, page 29
•
Opening a Web Client, page 31
Installing the ConfigTool IP Utility
Before you can start using your camera, you must install the ConfigTool IP utility on your PC.
1.
Insert the software CD that came with your camera into your PC’s disk drive.
2.
Open the Honeywell Config Tool folder, and then double-click Honeywell ConfigTool.exe.
3.
On the ConfigTool welcome screen, click Next.
4.
Read the User License Agreement. If you agree, select I agree.
5.
If you want, you can change the installation directory (by default, ConfigTool will be installed
in C:\Program Files). To proceed with the installation, click Install.
6.
If the installation is successful, the message "Installation is complete!" appears.
Click Enjoy Now to open ConfigTool.
800-21358 - A - 10/2015
28 | Performance Series IP Camera Software Configuration Guide
Discovering Your Device on the Network
Use ConfigTool to discover your IP device(s) on the network. To discover your device(s), open
ConfigTool. All of the connected IP devices on the network are listed. To refresh the list, click
Refresh.
Assigning a New IP Address to Your Device
The current IP address of your device appears in the IP column of the ConfigTool main interface.
If you want, you can assign a new static IP address to the device.
1.
From the list of devices in ConfigTool, click the device that you want to assign a new IP
address to.
2.
Click Login, type the login user name and password for the device (the default user name
is admin and the default password is 1234), and then click OK.
Figure 2-1
3.
Log In to a Device
On the Config screen, click the Net tab, type the new IP settings in the IP Address,
Subnet Mask, and Gateway fields, and then click Save.
www.honeywell.com/security
Getting Started | 29
Figure 2-2
Network Settings
Upgrading Your Device’s Firmware
Before you begin using your camera, make sure you have the latest firmware installed. You can
upgrade a single device or multiple devices at the same time.
To upgrade a single device:
1.
From the list of devices in ConfigTool, click the device that you want to upgrade.
2.
Click Login, type the login user name and password for the device (the default user name
is admin and the default password is 1234), and then click OK.
3.
On the Config screen, click the Upgrade tab.
4.
Click OpenFile, navigate to the directory that contains the firmware file, and then click
Upgrade.
Figure 2-3
Upgrade Screen
800-21358 - A - 10/2015
30 | Performance Series IP Camera Software Configuration Guide
When the upgrade is complete, the device will reboot. While the device is rebooting, the
message "Device is offline: [device IP address]" appears.
To upgrade multiple devices simultaneously:
1.
In ConfigTool, click Batch Mode.
Figure 2-4
2.
From the list of devices, click all of the devices that you want to upgrade, and then click
Start.
Figure 2-5
3.
Select Batch Mode
Batch Mode Screen
On the Batch Upgrade screen, click Open, navigate to the directory that contains the
firmware file, and then click OK.
www.honeywell.com/security
Getting Started | 31
Figure 2-6
Batch Upgrade Dialog Box
When the upgrade is complete, the devices will reboot. While a device is rebooting, the
message "Device is offline: [device IP address]" appears.
Opening a Web Client
You can configure individual camera settings using the web client. To open the web client from
ConfigTool, click the device that you want to open a web client for, and then, in the Operate
column, click the Microsoft Internet Explorer icon. The web client opens in your browser.
800-21358 - A - 10/2015
32 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
3
Logging In and Viewing Live Video
3
This chapter contains the following sections:
•
Logging In to the Camera via the Web Client, page 33
•
Using the Live View Interface, page 35
Logging In to the Camera via the Web Client
Using the web client, you can monitor live video, play back recorded video, and configure
camera settings.
Before You Begin
Before you log in to the web client, ensure that the following conditions are met:
•
The camera is properly connected to the network.
•
The camera’s IP address and the PC’s IP address are in the same network segment. If
there is a router, set the corresponding gateway and subnet mask.
•
A network connection has been established. To check this, ping the camera’s IP address.
(Enter "ping [IP address]").
Logging In to the Camera
1.
Open Internet Explorer, type the camera’s IP address in the address bar, and then click
Enter. For example, if your camera’s IP address is 192.168.1.108, you would type
http://192.168.1.108.
2.
On the login screen, enter the admin user name and password, and then click Login.
The default user name is admin (case-sensitive) and the default password is 1234.
800-21358 - A - 10/2015
34 | Performance Series IP Camera Software Configuration Guide
Figure 3-1
Login Window
Installing the Browser Plug-In
If you are logging in for the first time, you will be prompted to download and install a browser
plug-in. Follow the on-screen instructions to install the plug-in. When the installation is complete,
the web client automatically refreshes and the Live View interface opens (Figure 3-5).
If this is your first time logging in, you will see the following message:
Please click here to download and install the plug-in.
Figure 3-2
1.
First-time Login Message
Click Please click here to download and install the plug-in. A File
Download-Security Warning popup message appears (Figure 3-3) that asks if you would
like to run or save this file.
Figure 3-3
www.honeywell.com/security
File Download Security Warning Message for the Plug-in
Logging In and Viewing Live Video | 35
2.
Click Run. An Internet Explorer - Security Warning appears.
Figure 3-4
Internet Explorer - Security Warning
3.
Click Run to start the installation. A Ready to Install window appears.
4.
Click Install. A progress window appears.
When the plug-in installation is complete, the installation page automatically closes. Then
the web client automatically refreshes, and then Live View interface (Figure 3-5) opens.
Using the Live View Interface
The Live View interface can be divided into four areas.
Figure 3-5
Live View Interface
2
3
1
4
1
Video encoder settings area (see Video Encoder Settings, page 36)
2
System menus (see System Menus, page 36)
3
Live View controls toolbar (see Live View Controls, page 36)
4
Live View window settings toolbar (see Live View Window Configuration, page 37)
800-21358 - A - 10/2015
36 | Performance Series IP Camera Software Configuration Guide
Video Encoder Settings
In the video encoder settings area of the Live View interface, you can choose a stream and set
the stream protocol.
Figure 3-6
Video Encoder Settings
Table 3-1
Video Encoder Settings
Setting
Description
Main Stream
In a normal network bandwidth environment, the main stream
can record audio/video files and support a network monitor.
Set the main stream resolution if your camera supports it.
Sub Stream 1/
Sub Stream 2
Protocol
If the network bandwidth is not sufficient, you can use the sub
stream to support a network monitor.
Note Sub Stream 2 is available only for camera models
HED3PR3/ HBD3PR1/ H4D3PRV3/ HBD3PR2/
H4D3PRV2.
You can select the stream media protocol from the drop-down
list. There are three options: TCP, UDP, or Multicast.
System Menus
Figure 3-7
System Menu
When you log in to the camera using the web client, the Live View interface opens by default.
To access the Playback, Setup, and Alarm interfaces, or to log out, select the corresponding tab
in the system menus area.
Live View Controls
From the Live View controls toolbar, you can zoom in on a scene, take a snapshot, or manually
record video. These controls are described in more detail below.
Figure 3-8
www.honeywell.com/security
Live View Window Controls
Logging In and Viewing Live Video | 37
Table 3-2
Icon
Live View Window Controls
Control
Description
Digital Zoom
While viewing live video, click
and hold down the
left mouse button to zoom in on a specific area.
Right-click the mouse to return to the previous
magnification.
Snapshot
Click to take a snapshot, saved as a JPEG at the default
location (\picture download).
To change the save path, see Path on page 71. Or go
to Setup  Camera  Video  Path.
Triple Snap
Click to take three snapshots at 1 fps. All images are
saved to Setup  Camera  Video  Path.
Record
Click to start manual recording. All video is saved to
Setup  Camera  Video  Path.
Help
Click to open Help.
Note Help is available only for HED3PR3/HBD3PR1
/H4D3PRV3/H4D3PRV2/HBD3PR2 cameras.
Easy Focus
Note Easy focus is available only for
HBD3PR2/H4D3PRV2 cameras.
Click to open. You can see AF Peak and AF Max
adjustments on the Preview window. Select from AF
Peak and AF Max.
AF Peak: Displays the video’s definition when focusing.
AF Max: Displays the most suitable focus for video
definition.
The closer AF Peak and AF Max are, the better the
focus.
Live View Window Configuration
From the Live View window configuration toolbar, you can adjust the screen brightness,
contrast, hue, or saturation; change the screen size and/or aspect ratio; and adjust image
fluency. These controls are described in more detail below.
Figure 3-9
Live View Window Configuration Toolbar
800-21358 - A - 10/2015
38 | Performance Series IP Camera Software Configuration Guide
Table 3-3
Live View Window Configuration Tools
Image Control
Click to open the Image Adjustment panel. Drag the sliders
to set brightness, contrast, hue, and saturation, or click reset
to return to the default settings.
Alternatively, you can go to Setup  Camera  Conditions
to adjust these settings.
Note Image adjustments apply only to video displayed with
the web client interface.
Original Size
Click to return video display to original size (depends on
resolution of bit stream).
Full Screen
Click to enter full-screen mode. Press Esc or double-click the
mouse to exit full screen.
Width and
Height Ratio
Click to return video display to original aspect ratio (or an
aspect ratio suitable for the window).
Adjust Fluency
Click to select a fluency level based on your network
connection. The default setting is Normal. If your network
connection is slow, you can select Fluent to make the video
appear smoother (however, there may be a decrease in image
quality).
Zoom and Focus
Note This option is available only for HBD3PR2 and
H4D3PRV2 cameras.
Click to open the Zoom and Focus panel. Drag the sliders to
adjust the zoom and focus, and then click Auto Focus.
www.honeywell.com/security
4
Playing Back Video (HBD3PR2/H4D3PRV2 only) 4
This chapter contains the following sections:
•
Introduction, page 39
•
Playing Back Recorded Video, page 40
•
Using the Playback Assistant, page 43
•
Creating a Video Clip, page 44
•
Viewing Snapshots, page 44
Introduction
This chapter describes how to play back recorded video and saved snapshots on
HBD3PR2/H4D3PRV2 cameras using the web client, how to zoom in and take snapshots while
playing back recorded video using the Playback Assistant, and how to create custom video
clips.
Note
Before you can play back recorded video or saved snapshots, you must first
configure storage settings in the Setup menu. See Configuring Storage Settings
on page 70.
Note
Playback is currently only supported for HBD3PR2/H4D3PRV2 cameras.
Click the Playback tab to display the playback interface.
800-21358 - A - 10/2015
40 | Performance Series IP Camera Software Configuration Guide
Overview of the Playback Interface
The Playback interface has six areas with controls and options for playback (see Figure 4-1).
Figure 4-1
Playback Interface
6
2
1
3
4
1
2
3
4
5
6
Playback controls (see Playback Controls on page 40)
Calendar area (see Playing a Recorded File from the Calendar on page 41)
Clip selection (see Creating a Video Clip on page 44)
Record type (see Searching for a File by Recording Type on page 43)
Timeline configuration (see Timeline Configuration on page 43)
Playback Assistant (see Using the Playback Assistant on page 43)
Playing Back Recorded Video
Note
Playback is currently only supported for HBD3PR2/H4D3PRV2 cameras.
Playback Controls
Figure 4-2
www.honeywell.com/security
Playback Controls
5
Playing Back Video (HBD3PR2/H4D3PRV2 only) | 41
Table 4-1
Playback Controls
Control
Description
Click to play video. While in Play mode, this button changes to
the Pause button.
Click to stop video playback.
Click to go to the next frame.
Note Video playback must be paused before you can use
this function.
Slow playback.
Fast playback.
Mute sound.
Volume control.
Playing a Recorded File from the Calendar
On the playback calendar, a day in BLUE indicates a day on which video was recorded.
Figure 4-3
Playback Calendar
For the File Type, select dav for video playback and jpg for snapshots.
The default Data Source is SD Card.
Playing a Recorded File
1.
In the Playback interface, in the calendar area, use the options to find a recording:
a.
In the File Type box, select dav.
800-21358 - A - 10/2015
42 | Performance Series IP Camera Software Configuration Guide
b.
In the Data Src box, select SD Card.
c.
Select the month and year that you want to search. Dates with recorded video are
shown in blue.
d.
Click the date (in blue) that you want to view video for. The timeline (Figure 4-4)
displays the recordings for that day as color-coded bars.
•
Green indicates normal recording.
•
Yellow indicates motion detection recording
•
Red indicates alarm-triggered recording.
•
Blue indicates manual recording.
Figure 4-4
Recording Timeline
2.
Click on the timeline to select a playback time.
3.
Click
4.
Double-click a file in the file list to begin playback, and to see the file size, start time, and
end time. Use the Playback Controls, page 40, to review the video.
to open the list of recorded files.
Figure 4-5
Playback File Details
Enter a start and end time to search for recorded video.
Select a recording type. Select dav, as MP4 is not
supported.
Click the download button to download the dav file to
the local computer.
Click to return to the calendar interface.
Note
On the playback file interface, you can download a file to your local computer.
Note
Select dav for the recording type because MP4 is not supported.
www.honeywell.com/security
Playing Back Video (HBD3PR2/H4D3PRV2 only) | 43
Searching for a File by Recording Type
By selecting a recording file type, you can filter by a particular recording type so that the timeline
and file list display only those types of recorded files. You can also select the record type to
display in the Live View window. The filter is in the top of the Live View window.
Figure 4-6
Recording Type Filter in Live View
Timeline Configuration
You can configure the playback timeline in Live View to show the last 24 hours, 2 hours, 1 hour,
or 30 minutes of recorded video. Click to select.
Figure 4-7
Playback Timeline Configuration
Using the Playback Assistant
The Video Playback Assistant buttons allow you to zoom in and out on video, and to take
snapshots.
Note
Playback Assistant is currently only supported for HBD3PR2/H4D3PRV2
cameras.
Zooming In and Out
To zoom in, in the Playback Assistant area (see Figure 4-1), click the Zoom In button
then use the scroll wheel on your mouse to zoom in on an area of the video.
, and
Right-click the mouse to return the video to its original size.
Taking a Snapshot
Click
while playing video to manually take a snapshot. The snapshot is saved to the file
path on your local PC. To configure the file path, see Path on page 71.
800-21358 - A - 10/2015
44 | Performance Series IP Camera Software Configuration Guide
Creating a Video Clip
You can clip and save a section of recorded video during video playback using the clip function.
Note
Creating a video clip is currently only supported for HBD3PR2/H4D3PRV2
cameras.
Figure 4-8
Note
Clip Function Controls
Playback of recorded video is automatically paused during clipping.
1.
Find the recording that you want to create a clip from.
2.
On the timeline, click the recording at the time you want to start the clip, and then click
. This designates the start time of the clip.
3.
Next, click the recording at the time you want to end the clip, and then click
designates the end time of the clip.
4.
Click
to save the clipped file to your local PC. To configure the saving path, see Path
on page 71.
. This
Viewing Snapshots
Note
www.honeywell.com/security
Viewing snapshots is currently only supported for HBD3PR2/H4D3PRV2
cameras.
Playing Back Video (HBD3PR2/H4D3PRV2 only) | 45
Figure 4-9
Snapshot Playback Control Interface
Playback file bar
Play function bar
Snapshot type bar
1.
In the Playback interface, in the calendar area, do the following:
a.
In the File Type box, select jpg.
b.
In the Data Src box, select SD Card.
c.
Select the month and year that you want to search. Dates with snapshots are shown
in blue.
d.
Click the date (in blue) that you want to view snapshots for.
2.
In the Snapshot Type area, you can refine your search results by selecting specific
snapshot types to search (General, Motion, or Alarm).
3.
Click the file list button
selected date.
Figure 4-10
below the calendar to display a list of snapshots for the
List of Snapshots
Enter a time period to search for snapshots.
Click the download button to download the jpg file to
the local computer.
Click to return to the calendar interface.
800-21358 - A - 10/2015
46 | Performance Series IP Camera Software Configuration Guide
4.
If you want, you can refine your search results further by entering a specific time range to
search.
5.
To view a snapshot, double-click the file name (start time). To download a snapshot to
your local PC, click the download button next to the file name. To configure the saving
path, see Path on page 71.
www.honeywell.com/security
5
Configuring Camera Settings
5
This chapter contains the following sections:
•
Configuring Camera Settings, page 47
•
Configuring Network Settings, page 58
•
Configuring Storage Settings, page 70
•
Configuring System Settings, page 75
•
Viewing System Information, page 82
Configuring Camera Settings
Conditions
On the Conditions tab, you can view camera property information. The configurations become
valid immediately after they are saved.
Note
The settings that are available on the Conditions tab may differ depending on
the selections made in the Profile Management setup (see Profile Management
on page 51 for more information).
800-21358 - A - 10/2015
48 | Performance Series IP Camera Software Configuration Guide
Figure 5-1
Camera Setup Window
Table 5-1
Camera Configurations
Parameter
Function
Profile
Select from Normal, Day, Night.
Brightness
Adjusts monitor brightness. Choosing a higher value increases the video
brightness. Adjustments to this value affects the brightness of the video.
Select from 0 to 100. The recommended range is between 40 and 60. The
default value is 50.
Note If this value is too high, then the video can become hazy.
Contrast
Adjusts monitor contrast. Choosing a higher value increases the contrast.
Select from 0 to 100. The recommended range is between 40 and 60. The
default value is 50.
Note If this value is too low, then the video can become hazy. If this value
is too high, then the dark parts of the video could lose details, and
the bright parts of the video could become overexposed.
Saturation
Adjusts monitor color saturation. Choosing a higher value increases the
color saturation/strength. This value has no effect on the general brightness
of the video. Select from 0 to 100. The recommended range is between 40
and 60. The default value is 50.
Note You might see a distortion in grays if the white balance is off.
Sharpness
Adjusts video sharpness. Choosing a higher value increases the sharpness
of the video. Select from 0 to 100. The recommended range is between 40
and 60. The default value is 50.
Note Choosing a higher value can introduce video noise to the image.
Gamma
www.honeywell.com/security
Adjusts dynamic range. Choosing a higher value increases the brightness
of the image non-linearly. Select from 0 to 100. The recommended range is
between 40 and 60. The default value is 50.
Configuring Camera Settings | 49
Table 5-1
Camera Configurations (cont’d)
Parameter
Function
Anti-flicker
Outdoor: In Outdoor mode, you can select any exposure mode to avoid
flicker.
50Hz: When the current is 50Hz, the system can automatically adjust the
exposure according to the environment’s brightness to prevent stripes in
the video.
60Hz: When the current is 60Hz, the system can automatically adjust the
exposure according to the environment’s brightness to prevent stripes in
the video.
Auto
The video brightness can automatically change
according to the changes in the scene’s lighting. If
you set a higher gain max value, then you will get
less noise.
Low Noise
The video whole brightness can automatically
change within the proper exposure range according
to the different environments. The higher the gain
max value is, the lower the noise.
For the same environments, the noise of the low
noise mode shall be smaller than the noise of the
auto mode.
Exposure
Low Motion Blur
The video whole brightness can automatically
change within the proper exposure range according
to the different environments. The lower the gain max
value is, the weaker the tail.
For the same environments, the noise of the Low
Motion Blur mode will be smaller than that of the
Auto mode.
Manual
White Balance
Displays manual exposure values.
Sets the White Balance mode, which affects the general hue of the video.
This function is on by default.
You can select different scene modes such as Auto, Sunny, Outdoor,
Night, or Customized, to achieve the best quality video.
Auto: Auto white balance is on. The system automatically adjusts the color
temperature to ensure that the video color is correct.
Sunny: The white balance threshold is set to sunny mode.
Night: The white balance threshold is set to night mode.
Customized: You can manually set the gain for the red/blue channel. The
value ranges from 0 to 100.
Outdoor: The white balance threshold is set to outdoor mode.
800-21358 - A - 10/2015
50 | Performance Series IP Camera Software Configuration Guide
Table 5-1
Camera Configurations (cont’d)
Parameter
Function
Day & Night
Sets the camera color and the B/W mode switch. When the configuration file
is set to Normal, then the default is Auto. When the configuration file is set
to Day, then the default is Color. When the configuration file is Night, then
the default is Auto.
Color: The camera outputs video in color.
Auto: The camera switches from Color to Black & White according to the
conditions, such as if the scene is generally bright, or if IR illumination is
required.
Black & White: The camera outputs black and white video.
Sensitivity
Adjusts the sensitivity threshold at which the camera switches from Color to
Black & White mode. Set to Low, Medium (default), or High.
Note Available only when Day & Night is set to Auto.
Delay
Adjusts the delay value of the switch from Color to Black & White mode.
The value ranges from 2 to 10. The default value is 6.
Note Available only when Day & Night is set to Auto.
BLC Mode
OFF
BLC is off. BLC is disabled by default.
BLC (Default or
Customized)
The camera automatically adjusts the exposure to
suit the conditions, so that the darkest area of the
video can be seen. Default applies BLC to the entire
scene. Customized allows the user to apply BLC to a
specified portion of the scene.
WDR
By lowering the brightness of the brightest area, and
enhancing the brightness of the darkest area, WDR
balances brightness and darkness in a scene so that
both the darkest area and the lightest area can be
seen clearly at the same time.
This value ranges from 1 to 100.
Note When you switch the camera from non-WDR
to WDR mode, there might be a few seconds
lapse in video.
HLC
When the HLC function is enabled, the camera can
lower the brightness of the brightest section of video,
according to the selected HLC control level. HLC can
reduce the amount of halo and lower the brightness
of the entire video image.
This value ranges from 1 to 100. The default value is
50 when HLC is turned on.
HLC is enabled only when Anti-flicker is set to
Outdoor, and the Exposure is set to Auto.
Mirror
www.honeywell.com/security
Click to switch the video from left to right. This function is disabled by
default.
Configuring Camera Settings | 51
Table 5-1
Camera Configurations (cont’d)
Parameter
Function
Flip
No Flip: This is the default setting.
Flip 180°: Flips the video 180°.
Flip 90°: Rotates the video by 90°.
Flip 360°: Rotates the video by 360°.
3D Noise
Reduction
3D noise reduction is enabled by default.
3D NR Level
This value ranges from 0 to 100. The default is 50 when 3D NR is on.
Full-screen
Test
Click the
button on the bottom left of the video window to begin a
full-screen test. Double-click to return to the normal screen.
Default
Click to return the camera to the default setup.
Cancel
Click to cancel the current operation and restore the previously saved
operation.
Save
Click to save the currently configured customized settings.
Profile Management
Figure 5-2
Profile Management Tab
Profile management has three modes: Normal, Full Time, and Schedule.
•
Select Normal to configure the video as normal.
•
Select Full Time, and you must select either Day or Night for the video.
•
Select Schedule, and you can configure a detained time interval.
Note
When you make changes to the video configuration, you will immediately see the
effects of those changes in the video. However, you must click Save to save and
apply these settings.
800-21358 - A - 10/2015
52 | Performance Series IP Camera Software Configuration Guide
Zoom and Focus
Note
This section only applies to HBD3PR2 and H4D3PRV2 motorized focus/zoom
cameras.
Figure 5-3
Motorized Zoom and Focus
Table 5-2
Zoom and Focus
Parameter
Function
Zoom
Adjust the focal length of the lens by clicking "+" to zoom in or "–" to
zoom out. Changing the Speed setting adjusts the length of a
single-click increment.
Note After adjusting zoom, the lens will focus automatically.
Focus
Adjust the definition of the image by clicking "+" to focus far or "–" to
focus near. Changing the Speed setting adjusts the length of a
single-click increment.
Auto Focus
Click to adjust the focus automatically.
Restore All
Click to reset the lens to 0 position.
Note Reset the lens periodically if you are making a lot of zoom and
focus adjustments.
Refresh
www.honeywell.com/security
Refreshes the video image that is displayed.
Configuring Camera Settings | 53
Video Configuration
Video Bit Stream
Figure 5-4
Video Bit Stream Configuration Window
Table 5-3
Video Bit Stream Configurations
Parameter
Function
Select from General stream and Motion stream. You can select different
encoder frame rates for different recording events.
Code-Stream Type
The system supports the Active Control Frame (ACF) function. This allows
you to record in different frame rates.
For example, you can use a high frame rate to record important events, use
a lower frame rate to record scheduled events, and set a different frame rate
for recording motion detection.
Select from four options for Encode Mode: H.264 (Main Profile), H.264H
(High Profile), H.264B (Baseline Profile), and MJPEG mode.
Main Stream
H.264: Main profile encoding mode.
Encode Mode
H.264H: High profile encoding mode.
H.264B: Baseline profile encoding mode.
MJPEG: In this encoding mode, the video needs a larger bit stream to
guarantee the video definition. You can use the maximum bit stream value
in the Recommended Bit to get better video output.
Resolution
You can select from multiple resolutions from the drop-down list. The
recommended bit stream value is different for each resolution.
800-21358 - A - 10/2015
54 | Performance Series IP Camera Software Configuration Guide
Table 5-3
Parameter
Video Bit Stream Configurations (cont’d)
Function
Frame Rate (FPS)
PAL: 1~25 fps; NTSC: 1~30 fps.
Select either VBR or CBR.
Bit Rate Type
Note You can set the video quality in VBR mode.
Reference Bit
Stream
Main Stream
Bit Rate
I Frame Interval
Displays the Reference Bit Rate value according to the resolution and
frame rate that you have selected.
In VBR, the Bit Rate here is the maximum value. In CBR, it is a fixed value.
See the Reference Bit Stream for a recommended value.
Set the number of P-frames between I-frames. The value ranges from 25 to
150. The default value is 50.
The recommended value for I Frame Interval is 2 times the frame rate setting.
Watermark
Enable
Code-stream Type
This function allows you to verify that the video has not been altered. Select
to enable the watermark function, and then type the watermark text. The
default watermark text is DigitalCCTV. The maximum length is 85 digits.
Only numbers, letters, and the underscore character ( _ ) can be used.
Click the check box to enable the extra stream.
This function is enabled by default.
General bit stream.
Select from four options for Encode Mode: H.264 (Main Profile), H.264H
(High Profile), H.264B (Baseline Profile), and MJPEG mode.
H.264: Main profile encoding mode.
Encode Mode
H.264H: High profile encoding mode.
H.264B: Baseline profile encoding mode.
MJPEG: In this encoding mode, the video needs a larger bit stream to
guarantee the video definition. You can use the maximum bit stream value
in the Recommended Bit to get better video output.
Resolution
There are multiple resolutions to select from the drop-down list. The
recommended bit stream value is different for each resolution.
Frame Rate
PAL: 1~25 fps; NTSC: 1~30 fps.
Sub Stream
Select either VBR or CBR.
Bit Rate Type
Note You can select the video quality in VBR mode. The value ranges from
1 to 6.
Recommended Bit
Rate
Recommended bit rate value according to the resolution and frame rate you
have set.
Bit Rate
In CBR, the bit rate here is the maximum value. In dynamic video, the
system needs a lower frame rate or lower video quality to adapt to the
current bandwidth.
I Frame Interval
Set the number of P-frames between I-frames. The value ranges from 25 to
150. The default value is 50.
The recommended value for I Frame Interval is 2 times the frame rate setting.
www.honeywell.com/security
Configuring Camera Settings | 55
Snapshot
Figure 5-5
Snapshot Configuration Interface
Table 5-4
Snapshot Configurations
Parameter
Function
Shapshot Type
Select from either General (schedule) or Event (activation).
Image Size
Same as the main stream resolution.
Quality
Select from six levels of image quality.
Interval
Set the snapshot frequency from 1s to 7s.
Note
See ROI on page 56 for information about configuring where snapshots are
saved. Snapshots are saved as JPEGs.
800-21358 - A - 10/2015
56 | Performance Series IP Camera Software Configuration Guide
Video Overlay
Figure 5-6
Video Overlay Configuration Interface
Table 5-5
Video Overlay Configurations
Parameter
Privacy Mask
Function
Masks areas of the video for privacy.
You can configure up to four (4) privacy mask zones.
Channel Title
Enable this function to overlay channel information in the video
window. Use the mouse to drag the channel title to the desired
position.
Time Title
Enable this function to overlay time information in the video
window. Use the mouse to drag the time to the desired position.
Text Overlay
Enable this function to overlay text in the video window. Enter the
text to be overlayed in the Input field and select Right or Left
alignment from the drop-down menu.
ROI
Note
www.honeywell.com/security
ROI is only available for HED3PR3, HBD3PR1, H4D3PRV3, H4D3PRV2, and
HBD3PR2 cameras.
Configuring Camera Settings | 57
Figure 5-7
ROI Interface
Table 5-6
ROI Configurations
Parameter
Function
Enable/Disable
Enable or disable the Region of Interest (ROI) feature.
Image Quality
Select the image quality required for the region of interest.
Path
Figure 5-8
Storage Path Interface
Set the storage path for snapshots (
in the live interface) and for recorded video (
the live interface). The default path for snapshots is C:\Honeywell Video
Systems\LiveSnapshot. The default path for recorded video is C:\Honeywell Video
Systems\LiveRecord.
in
Click Save to save any changes to the storage paths.
800-21358 - A - 10/2015
58 | Performance Series IP Camera Software Configuration Guide
Configuring Network Settings
TCP/IP
Figure 5-9
TCP/IP Interface
Table 5-7
TCI/IP Configuration
Parameter
Function
Host Name
Configure to set the current host camera’s name. Maximum 32
characters.
Select an Ethernet port. The default is wire LAN.
Ethernet Card
Note If you modify these settings, you will have to reboot your
camera to activate the new setup.
Select Static or DHCP mode.
The IP Address, Subnet mask, and Default Gateway are greyed out
when you select DHCP mode to automatically search for the IP
address.
Mode
If Static mode is selected, you must manually assign the IP
Address, Subnet mask, and Default Gateway.
If DHCP mode is selected, the IP Address, Subnet mask, and
Default Gateway are assigned automatically.
Note IP Address, Subnet mask, Default Gateway, and DHCP
are read-only when PPPoE is enabled.
MAC Address
www.honeywell.com/security
Displays the MAC address.
Configuring Camera Settings | 59
Table 5-7
TCI/IP Configuration
Parameter
Function
IP Version
Select the IP version you are using: IPv4 or IPv6.
IP Address
If Static mode is selected, type values for the IP Address, Subnet
mask, and Default Gateway.
Preferred DNS
Server
Enter the preferred DNS server IP address.
Alternate DNS
Server
Enter an alternate DNS server IP address.
If you know the camera’s MAC address, then use the ARP/Ping
command to modify or set the camera’s IP address.
Before operating the camera, please ensure that the network
camera and the PC are in the same LAN. This function is On by
default.
To enable ARP/Ping to set the IP address service:
1. Get an IP address. Set up the network camera and the PC in the
same LAN.
2. Get the physical address from the label on the network camera.
Enable ARP/Ping
to set IP Address
Service
3. Open the Run interface (Start menu > Run), and then type the
following commands:
arp -s <IP Address> <MAC>
ping -l 480 -t <IP Address>
For example:
arp -s 192.168.0.125 11-40-8c-18-10-11
ping -l 480 -t 192.168.0.125
4. Reboot the camera. If the setup was successful, output
information such as Reply from 192.168.0.125... will
appear in the command output lines.
5. Close the command line.
6. Open your browser, type http://<IP address> in the address
bar, and then press Enter.
800-21358 - A - 10/2015
60 | Performance Series IP Camera Software Configuration Guide
Connection
Figure 5-10
Connection Configuration Interface
Table 5-8
Connection Configurations
Parameter
Function
Max Connection
This shows the maximum number of network connections for the same
camera. The value ranges from 1 to 20. The maximum number of
connections is 20.
TCP Port
The default setting is 37777. You can modify this setting as necessary.
UDP Port
The default setting is 37778. You can modify this setting as necessary.
HTTP Port
The default setting is 80. You can modify this setting as necessary.
RTSP Port
The default setting is 554. The RTSP stream query format is:
Main stream:
rtsp://username:password@ip:port/cam/realmonitor?ch
annel=1&subtype=0
Sub stream:
rtsp://username:password@ip:port/cam/realmonitor?ch
annel=1&subtype=1
You are required to manually enter the following four items: Username,
Password, IP, and Port.
IP: The camera’s IP address.
Port: The default is 554. You can leave this field blank if you are using
the default value.
Follow standard RTP protocols. When the encode mode is MJPEG, the
maximum supported resolution is 2040×2040.
HTTPs
Enable the HTTPs port.
HTTPs Port
The default is 443.
www.honeywell.com/security
Configuring Camera Settings | 61
ONVIF
ONVIF (Open Network Video Interface Forum) is a global open standard for the interface of
IP-based security products. It covers network video mode, interface, data type, and data
interaction mode. The ONVIF specification aims at interoperability of network video products
regardless of manufacturer.
The ONVIF setting is disabled by default.
•
To enable ONVIF, on the ONVIF tab, click Enable.
•
To disable ONVIF, on the ONVIF tab, click Disable.
PPPoE
Figure 5-11
PPPoE Configuration Interface
1.
Enter the PPPoE Username and Password that you received from the Internet Service
Provider (ISP), and enable the PPPoE function.
2.
Click to Save the current setup, and then reboot the camera to activate this new setup.
The camera connects to the Internet via PPPoE after rebooting.
3.
Find the IP address in the WAN from the IP address column.
Note
When PPPoE is enabled, disable UPnP so that it does not interfere with PPPoE.
Note
You must go to the IP address to check the camera’s current information. You
can access the web client through this address.
800-21358 - A - 10/2015
62 | Performance Series IP Camera Software Configuration Guide
DDNS
Manually Configuring the DDNS
Figure 5-12
DDNS Configuration Interface
To set the DDNS, go to the corresponding service website to apply a domain name, and then
access the system through that domain. This works even if your IP address has changed.
Table 5-9
DDNS Configurations
Parameter
Function
Server Type
You can select the DDNS protocol from the drop-down list, and then
enable the DDNS function. Select the Honeywell DDNS server (which is
free) to enable the DDNS function.
Server Address
The DDNS server IP address.
Domain Name
Your self-defined domain name.
Username
The user name you enter to log into the server.
Password
The password you enter to log into the server.
Update Period
The frequency at which the camera regularly sends out the life signal
(heartbeat) to the server. You can set the interval value between the
camera and the DDNS server here.
www.honeywell.com/security
Configuring Camera Settings | 63
Using Honeywell DDNS to Configure DDNS
Figure 5-13
Using Honeywell DDNS to Configure DDNS
Set the DDNS to connect the Honeywell DDNS server so that you can access the system
through the servers.
Table 5-10
Honeywell DDNS Configurations
Parameter
Function
Server Type
You can select the DDNS protocol from the drop-down list, and
then enable the DDNS function. Select the Honeywell DDNS server
(which is free) to enable the DDNS function.
Server Address
This is the DDNS server IP address. Under Honeywell DDNS, the
default server address is www.hennvr-ddns.com.
Mode
Select Auto or Manual. The default is Auto. If you select Manual,
then you must enter a domain name.
Domain Name
Auto and self-defined domain names are both MAC
address.hennvr-ddns.com. You can define the prefix.
Username
The user name you enter to log in the server (optional).
IP Filter
Enable the IP filter function so that only the specified IP/MAC addresses can access the network
camera. You can specify an IP address or an IP address segment (for example, from
192.168.1.1 to 192.168.1.100). If you do not check the box to enable Trusted Sites, there will
be no access limitation.
800-21358 - A - 10/2015
64 | Performance Series IP Camera Software Configuration Guide
Figure 5-14
IP Filter Configuration Interface
Before you can restrict access to the cameras through the IP filter, you must first configure the
Trusted Sites here.
Note
Add these addresses before enabling Trusted Sites.
Note
If you specify a MAC address limitation here, the computer with the specified
MAC address must be in the same network subnet as the IP camera.
CAUTION
If you setup the IP Filter/Trusted sites options and forget
the IP/MAC address that is allowed to access the camera, you will have to
return the camera to the factory to repair the problem.
www.honeywell.com/security
Configuring Camera Settings | 65
SMTP (Email)
Figure 5-15
SMTP Configuration Interface
Table 5-11
SMTP (Email) Configurations
Parameter
Function
SMTP Server
Enter the server address.
Port
The default setting is 25. You can modify this setting as necessary.
Anonymity
Supports the anonymity function for the server. You can automatically
login anonymously. You do not need to enter the user name, password,
and the sender information.
Username
The username for the sender’s email account.
Password
The password for the sender’s email account.
Sender
The sender’s email address.
Authentication
Enable
This is the encryption mode. Select SSL, TLS, or None.
Title
Subject: Enter the email subject here.
Attachment
Check this box to have the system send out an email with the snapshot
picture.
Mail Receiver
Enter the receiver’s email address here. You can add up to three
addresses.
800-21358 - A - 10/2015
66 | Performance Series IP Camera Software Configuration Guide
Table 5-11
SMTP (Email) Configurations (cont’d)
Parameter
Function
Interval
The interval for sending ranges from 0 to 3600 seconds. 0 seconds
means that there is no interval.
The system will not immediately send the email when the alarm occurs.
When an alarm, motion detection, or abnormality occurs to activate an
email, the system sends the email according to the interval that you
have specified here. This reduces the load on the email server when
numerous emails are triggered simultaneously.
Health Mail Enable
Select the check box to enable this function.
Update Period
(interval)
This allows the system to send a test email to check the connection.
Select the check box to enable this function, and then set the
corresponding email interval.
You can set the Update Period so that the system sends out regularly
scheduled emails.
Email Test
The system will automatically send an email to test the connection.
Before you can do an email test, you must save the email setup
information.
UPnP
UPnP lets you establish the mapping relationship between the LAN and the public network. In
the UPnP configuration interface, you can add, modify, or remove a UPnP item.
Figure 5-16
UPnP Configuration Interface
Enabling UPnP in Windows
When UPnP is enabled in Windows, the camera can be detected automatically through My
Network Places.
Note
www.honeywell.com/security
The UPnP are enabled by default on Windows 7 systems. This procedure applies
to Windows XP.
Configuring Camera Settings | 67
1.
Go to Start  Control Panel  Add or remove programs.
2.
Click Add or remove programs, and then select Network Services from the Windows
Components Wizard.
3.
Click Details, and then click to select Internet Gateway Device Discovery and Control
client and UPnP User Interface.
4.
Click OK to begin the installation.
Bonjour
Bonjour is based on the multicast DNS service from Apple. It can automatically broadcast its
service information and listen to the camera information from the other camera.
Figure 5-17
Bonjour Configuration Interface
If you do not know the network camera’s information, such as its IP address, you can use
Bonjour’s browser in the same LAN to search for and access network cameras. After the
network camera is detected by Bonjour, you can see the server name.
1.
Click Display All Bookmarks in your browser.
2.
Open Bonjour. The system should automatically detect network cameras through Bonjour
on the LAN.
Multicast
Multicast is a transmission mode for data packets. When there are multiple hosts to receive the
same data packet, multiple cast (multicast) is the best option for reducing the bandwidth and
the CPU load. The source host can send out just one data packet. This function depends on the
relationship between group members and the router’s group.
In the Multicast configuration interface, you can set the multicast address and port.
Note
You also need to go to the Live interface to set the protocol to Multicast. See
Protocols in Video Encoder Settings on page 36.
800-21358 - A - 10/2015
68 | Performance Series IP Camera Software Configuration Guide
Figure 5-18
Multicast Configuration Interface
Table 5-12
Multicast Configurations
Parameter
Function
Enable
Select the check box to enable the multicast function.
Note Main stream and sub stream cannot be used at the same time.
Multicast Address
The main/sub stream multicast address is 239.255.42.42 and its range
is 224.0.0.0~239.255.255.255.
Port
Multicast port. The main stream is 36666; the sub stream is 36667, and
the range is 1025~65534.
IEEE802.1X
IEEE802.1X is the access control and authentication protocol for local and metropolitan area
networks. It uses a port-based network access control protocol to restrict unauthorized user
and/or device access to the LAN.
IEEE802.1X supports the client’s ability to manually choose how authentication works for
accessing the LAN or not. IEEE802.1X supports the ability to:
•
authenticate
•
calculate the fee
•
ensure security
•
maintain requirements
www.honeywell.com/security
Configuring Camera Settings | 69
Figure 5-19
802.1X Configuration Interface
Table 5-13
802.1X Configurations
Parameter
Function
Authentication
PEAP (protected EAP protocol)
Username
Enter a username to log in. This username is authenticated by the
server.
Password
Enter a password.
QoS
Quality of Service (QoS) is a network security mechanism. It fixes problems with network delay
and jams. For network service, the quality of service includes the transmission bandwidth, delay,
and packet loss, for example. Through QoS, we can guarantee the transmission bandwidth, to
reduce the delay, to reduce the loss of data packets, and to enhance the quality with packet
prioritization.
Figure 5-20
QoS Configuration Interface
Table 5-14
QoS Configurations
Parameter
Function
Realtime Monitor
This value ranges from 0 to 63. The router or the switcher can provide
different service for different packets.
Command
This value ranges from 0 to 63. The router or the switcher can provide
different service for different packets.
800-21358 - A - 10/2015
70 | Performance Series IP Camera Software Configuration Guide
Configuring Storage Settings
Recording Schedule and Snapshot Schedule
You can add or remove schedules for recording and snapshots. There are two recording
modes: General (auto) and Motion Detection. You can configure up to six recording periods
per day.
Note
Ensure that you have enabled the corresponding recording mode in
Setup  Storage  Conditions.
Figure 5-21
Recording Schedule Configuration Interface
Recording Schedule Color Codes:
•
Green: General recording/snapshot
•
Yellow: Motion detection recording/snapshot
Setting Holidays
You can set specific days as holidays, for which the recording schedule is different. When
enabled, the selected/configured dates will record according to the holiday setup.
www.honeywell.com/security
Configuring Camera Settings | 71
Figure 5-22
Holiday Schedule
Destination
Path
On the Path tab, you can assign where recorded video files or snapshots will be saved.
Depending on your camera model, you can save recorded video or snapshots to a Micro SD
card, an FTP server, and/or an NAS disk.
You can also set up the system to save recorded video files and snapshots according to event
type (Scheduled, Motion Detect, Alarm), corresponding to the three record modes in the
Schedule Interface (General, Motion, Alarm).
Figure 5-23
Path Configuration Interface
Table 5-15
Path Configurations
Parameter
Function
Event Type
Select Scheduled, Motion Detect, or Alarm.
800-21358 - A - 10/2015
72 | Performance Series IP Camera Software Configuration Guide
Table 5-15
Path Configurations
Parameter
Function
Local
Select to saves files to the Micro SD card
FTP
Select to save files to the FTP server.
NAS
Select to save files to the NAS disk.
Local
On the Local tab, you can view local Micro SD card or NAS disk information. You can also
access the Read Only, Read & Write, Hot Swap, and Format functions.
Figure 5-24
Local Storage Configuration Interface
FTP
On the FTP tab, you can enable the FTP storage function. When enabled, event-triggered video
and snapshots (either scheduled or motion detection, depending on what you chose in
Figure 5-23) will be saved to the specified FTP server.
www.honeywell.com/security
Configuring Camera Settings | 73
Figure 5-25
FTP Configuration Interface
Table 5-16
FTP Configurations
Parameter
Function
Server Address
Set the IP address of the server.
Port
The default setting is 21. You can modify this setting as necessary.
User Name
Enter the server user name.
Password
Enter the server password.
Remote Directory
Set storage directory where recorded video and snapshots will be
stored.
Emergency (Local)
Enable Emergency (Local) to save to the local Micro SD card when the
network connection to FTP is unavailable.
800-21358 - A - 10/2015
74 | Performance Series IP Camera Software Configuration Guide
NAS
Figure 5-26
NAS Configuration Interface
Table 5-17
NAS Configurations
Parameter
Function
Server Address
Set the IP address of the server.
Remote Directory
Set storage directory where recorded video and snapshots will be
stored.
Record Control
Figure 5-27
Record Control Configuration Interface
Table 5-18
Record Control Configurations
Parameter
Function
Pack Duration
Select the file size. The default is 8 minutes.
Pre-event Record
Enter a pre-record value.
For example, the system can record the four seconds of video in the
buffer. Recording begins five seconds before the event trigger.
www.honeywell.com/security
Configuring Camera Settings | 75
Table 5-18
Record Control Configurations (cont’d)
Parameter
Function
Disk Full
Select Stop Recording or Overwrite the previous files when the HDD
is full.
Overwrite: If the current working HDD is full, then the system will
overwrite the previous file.
Stop: If the current working HDD is full or is overwriting, the system will
stop recording.
Record Mode
Select Auto, Manual, or Off.
Record Stream
Select Main Stream or Sub Stream.
Configuring System Settings
General System Setup
The general interface includes the local host setup (including the camera name and GUI
language), and the date/time setup.
General
Figure 5-28
General System Configuration Interface
Table 5-19
General System Configurations
Parameter
Function
Device Name
Enter the camera’s name.
Language
Select a language from the drop-down list.
Video Standard
Select the video standard: NTSC or PAL.
800-21358 - A - 10/2015
76 | Performance Series IP Camera Software Configuration Guide
Date and Time
Figure 5-29
Date and Time Configuration Interface
Table 5-20
Date and Time Configurations
Parameter
Function
Date Format
Select a date format from the drop-down list.
Time Format
Select a time format, either 24-hour or 12-hour.
Time Zone
Select the time zone for the camera.
Current Time
Set it to set the system’s time. You have to Save to activate this time.
Sync PC
Click to sync the camera’s time with your PC’s time.
DST
Set when Daylight Saving Time begins and ends. Select Date or Week.
NTP
Click to enable NTP.
NTP Server
Configure the NTP time server.
Port
Configure the port for the NTP time server.
Update Period
Configure synchronization periods between the camera and the time
server.
Account Setup
The system supports up to 15 characters for the user name or user group name. You can use
letters, numbers, and the underscore character ( _ ) for the user or group name.
You can configure up to 18 users and eight groups (default factory settings). The factory default
setup includes two user levels: user and admin (case-sensitive).
www.honeywell.com/security
Configuring Camera Settings | 77
When configuring groups, you can configure the rights of those groups. You can also set rights
for individuals within groups.
Note
User management adopts group/user modes. The user name and the group
name should be unique. A user can be included in only one group at a time.
User Name
In the Username Configuration interface, you can enable anonymous login, add/remove
users, and modify a username.
Figure 5-30
Username Configuration Interface
Enable Anonymous Login: Click to enable. When you enter an IP, no username or password
is required. You can log in anonymously (with limited rights). Click Logout to end your
anonymous session.
Add User: Add a user to a group and configure that user’s rights.
800-21358 - A - 10/2015
78 | Performance Series IP Camera Software Configuration Guide
Figure 5-31
Add User Configuration Interface
There are two types of default user:
•
admin
•
hidden user "default"
The hidden user "default" is for internal system use only and cannot be deleted. When there is
no login user, this hidden user "default" is automatically used for logging in. You can configure
some rights for the hidden user, such as monitoring ability, so that the user can view channels
without logging in.
To add a user, in the Add User configuration interface, enter a user name and password, then
select a group. Ensure that the general user has lower rights than the admin user.
Note
User rights cannot exceed the rights of the group to which that user belongs.
Modifying Users: Click
and rights.
Figure 5-32
www.honeywell.com/security
to modify a user’s properties, including their group, passwords,
Modifying User Interface
Configuring Camera Settings | 79
Modifying a Password: Enter the old password once, and then enter the new password twice
to confirm the new password. Click Save to save the new settings.
Note
Passwords can contain up to 32 characters, using numbers and letters only.
Only users with account rights can modify other users’ passwords.
Group
In the Group configuration interface, you can add/remove groups and modify group passwords.
Figure 5-33
Group Configuration Interface
Adding a Group: Add a group and configure that group’s rights. Enter the group name, and
then check the box to select the corresponding rights (Live, Record Control, Account).
Figure 5-34
Add Group Interface
Modifying a Group: Click Modify Group to open the Modify Group interface.
800-21358 - A - 10/2015
80 | Performance Series IP Camera Software Configuration Guide
Figure 5-35
Modify Group Interface
In the Modify Group Interface, you can edit Remarks and Rights.
Restoring Default Settings
Click Default to restore the camera to its factory default settings.
Figure 5-36
Note
www.honeywell.com/security
Default Interface
The system cannot reset some information, such as the network IP address.
Configuring Camera Settings | 81
Import/Export
Figure 5-37
Import/Export Configuration Interface
Table 5-21
Import/Export Configurations
Parameter
Function
Import
Click to import local setup files to the system.
Export
Click to export the corresponding system setup to your local PC.
Automatic Maintenance
You can select either Auto Reboot, Auto Delete Old Files, or Manual Reboot.
Figure 5-38
Auto Maintain Configuration Interface
800-21358 - A - 10/2015
82 | Performance Series IP Camera Software Configuration Guide
Upgrade
Figure 5-39
Upgrade Interface
Select the upgrade file, and then click Upgrade to begin the firmware update.
CAUTION
Selecting the incorrect upgrade file might cause a
camera malfunction.
Viewing System Information
Version
In the Version interface, you can view the system hardware features, the software version, and
the release date. This information is for reference only.
Figure 5-40
www.honeywell.com/security
Version Interface
Configuring Camera Settings | 83
Log
Figure 5-41
Log Interface
Table 5-22
Log Interface Configurations
Parameter
Function
Start Time
Configure the start time for the requested log.
End Time
Configure the end time for the requested log.
Type
Select a log type: System, Operation, Configuration Operation, Data
Operation, Event Operation, Record Operation, Account
Management, Log Clearing.
Search
Select a log type from the drop-down list, and then click Search to view
the list that is generated by the search. Click Stop to terminate the
current search.
Log Information
Select one item to view its detailed information.
Backup
Click Backup to back up log files to the currently selected PC.
Clear
Click Clear to delete all the displayed log files.
Note The system does not support clearing by type.
Online User
You can view the current online user, group name, IP address, and login time.
800-21358 - A - 10/2015
84 | Performance Series IP Camera Software Configuration Guide
Figure 5-42
www.honeywell.com/security
Online User Interface
6
Configuring Events and Alarms
6
This chapter contains the following sections:
•
•
•
•
Configuring for Motion Detection on page 85
Configuring for Camera Tampering on page 88
Configuring for Abnormalities on page 89
Configuring Alarms on page 92
Configuring Events
Configuring for Motion Detection
Video Motion Detection
Figure 6-1
Motion Detection - Video Detection Configuration Interface
800-21358 - A - 10/2015
86 | Performance Series IP Camera Software Configuration Guide
Table 6-1
Video Motion Detection - Video Detection Configurations
Parameter
Function
Enable
Check to enable motion detection.
Working Period
Configure the arm/disarm period. Click Setup to open the setup
menu. See Configuring the Working Period on page 86.
Anti Dither
The system memorizes only one event during the anti-dither period.
Choose an anti-dither period from 0s to 100s.
Area
Configure the motion detection region, its sensitivity, and area. The
default settings covers the entire area. You must click Save to
enable these settings. See Configuring the Motion Detection Area on
page 87.
Record
When Record is enabled, you can trigger motion detection to
activate recording.
Record Delay
The system can delay recording for a specified time after the alarm
has ended. Choose a delay period from 10s to 300s.
Send Email
When this function is enabled, the system sends an email alert to
you when an alarm occurs.
Snapshot
Check to enable the system to backup motion detection snapshot
files. (See Path on page 71 for information about configuring where
snapshots are saved.)
Configuring the Working Period
Figure 6-2
www.honeywell.com/security
Configuring the Working Period
Configuring Events and Alarms | 87
Configuring the Motion Detection Area
Figure 6-3
Configuring the Motion Detection Area
Table 6-2
Motion Detection Area Configurations
Parameter
Function
Sensitivity
Adjust the brightness sensitivity. You might need to increase the
brightness sensitivity to trigger motion detection. You can
configure up to four areas. The sensitivity ranges from 0 to 100. We
recommend that you choose a sensitivity between 30 to 70. The
default is 50.
Threshold
The threshold determines how much change in a scene is required
to trigger an alarm. The lower the threshold setting, the easier it is
to trigger a motion detection alarm. You can configure up to four
areas. The sensitivity ranges from 0 to 100. We recommend that
you choose a sensitivity between 10 to 50.
Delete All
Delete all motion detection areas.
Delete
Delete the selected motion detection area.
800-21358 - A - 10/2015
88 | Performance Series IP Camera Software Configuration Guide
Configuring for Camera Tampering
Figure 6-4
Tampering Configuration Interface
Table 6-3
Tampering Configurations
Parameter
Function
Enable
Check to enable the Tampering function (Video Tamper and/or
Defocus Detect).
Note Defocus Detect is only available with the HBD3PR2 and
H4D3PRV2 camera models.
Working Period
The video masking feature is activated during the specified period.
See Configuring the Working Period on page 86.
You can configure up to six periods per day. Draw a circle to enable
the corresponding time period.
Select a date. If you do not select a date, the current setup will be
applied to today only. You can select All to apply the working
period to the whole week.
Click OK to save the changes. The system goes back to the Motion
Detection interface. Click Save to exit.
www.honeywell.com/security
Record
If Record is enabled, a video masking event can activate recording.
Record Delay
The system will wait for the specified time before it begins
recording. Select from 10s to 300s.
Send Email
When enabled, the system sends an email alert when an alarm
occurs.
Snapshot
When enabled, the system automatically sends an email when an
alarm occurs.
Configuring Events and Alarms | 89
Figure 6-5
Tampering Working Period Configuration Interface
Configuring for Abnormalities
Abnormalities include No SD Card, Capacity Warning, SD Card Error, Disconnection, IP
Conflict, and Unauthorized Access.
Note
Only cameras with Micro SD cards (HBD3PR2 and H4D3PRV2) can encounter the
following abnormalities: No SD Card, Capacity Warning, and SD Card Error.
Configuring for Micro SD Card Abnormalities
Micro SD card Abnormalities include No SD Card, SD Card Error, and the Capacity Warning.
Figure 6-6
No SD Card Warning Configuration Interface
800-21358 - A - 10/2015
90 | Performance Series IP Camera Software Configuration Guide
Figure 6-7
SD Card Error Warning Configuration Interface
Figure 6-8
Capacity Warning Configuration Interface
1.
Click Enable so that an alarm is triggered when a Micro SD card error occurs.
2.
Click Email so that an email is sent to a specified receiver if a Micro SD card error occurs.
Note
www.honeywell.com/security
Emails cannot be sent if the network is offline or if there is an IP conflict.
Configuring Events and Alarms | 91
Configuring for Network Abnormalities Such as Network
Disconnections and IP Conflicts
Figure 6-9
Dicsonnection Configuration Interface
Figure 6-10
IP Conflict Configuration Interfacet
1.
Click Enable so that an alarm is triggered when there is a network disconnection or an IP
conflict.
2.
Click Record so that the system records video to the Micro SD card when there is a
network disconnection or an IP conflict.
Configuring for Illegal Access
If someone attempts multiple times to login using an incorrect password, and Illegal Access
alarm occurs. You can specify how many attempts can be made before the Illegal Access alarm
occurs.
800-21358 - A - 10/2015
92 | Performance Series IP Camera Software Configuration Guide
Figure 6-11
Illegal Access Configuration Interface
1.
Click Enable so that an alarm is triggered when someone tries to illegally access the
camera.
2.
Enter the number of times a user can attempt to log in. Select from 3 to 10.
3.
Click Email so that an email is sent to a specified receiver if someone attempts to illegally
access the camera.
Configuring Alarms
Click the Alarm tab to open the alarm configuration interface.
Figure 6-12
www.honeywell.com/security
Alarm Configuration Interface
Configuring Events and Alarms | 93
Table 6-4
Type
Alarm Type
Operation
Alarm Configurations
Parameter
Function
Motion Detection
System alarms when a motion detection alarm
occurs.
Tampering
System alarms when the camera has been
tampered with.
Disk Full
System alarms when the disk (Micro SD card) is
full.
Disk Error
System records alarm information when a disk
error occurs.
Illegal Access
System alarms when someone attempts to
illegally access the camera.
Prompt
System pops up an alarm dialog box.
Play Alarm Tone
When an alarm occurs, the system automatically
generates an audible sound. You can select a
tone from your PC for the alarm tone prompt.
Tone Path
Select the alarm sound file.
Alarm Tone
800-21358 - A - 10/2015
94 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
A
Troubleshooting
A
Refer to the following guidelines to troubleshoot any performance issues. If you require
additional assistance, contact Honeywell Technical Support (see back cover for contact
information).
Cannot play downloaded file.
• Use the player located on the CD that came with your camera.
• Ensure that DirectX8.1 or higher is installed on your PC.
• Install the DivX503Bundle.exe plugin for playing AVI files.
• If you are running Windows XP, install the ffdshow codec.
Cannot set camera frame rate
above 20 fps when Embedded NVR
resolution set at 1080p or lower.
1. On the NVR, go to NVR setup and set the resolution to 1080p
and click Save.
2. Go to Remote Device and click Delete to remove the camera.
Then select the camera in the Searched Device area and click
Add.
3. Click Modify for the camera in the Added device area. Select
ONVIF from the drop-down list of manufacturers and click
Save.
You can now set the frame rate at 20 fps or above for 1080p or
lower resolutions at the NVR end.
Cannot get 3 MP resolution at the
NVR.
1. Make sure the NVR supports 3 MP (2304×1296) resolution
(see Table A-1).
2. On the NVR, go to NVR setup  Remote Device and click
Modify for the 3 MP camera in the added device area. Select
ONVIF from the drop-down list of manufacturers and click
Save. You can now setup 3 megapixel resolution on the NVR
end.
IR video is poor.
• Ensure that the power supply is adequate. An inadequate
power supply may not be able to support the IR lights.
• Ensure that the objects to be illuminated are within the camera’s
IR range.
• If the IR-cut filter does not switch to Night mode, the
photosensitive chip at the front of the camera may be
malfunctioning.
Cannot upgrade firmware through
the network
• If you cannot upgrade firmware over the network, try using port
3800.
800-21358 - A - 10/2015
96 | Performance Series IP Camera Software Configuration Guide
Cannot install/log in to web client.
• Ensure that your browser’s security settings allow ActiveX
controls.
• Ensure that DirectX8.1 or higher is installed on your PC.
• Ensure that you have a valid network setup and that you are
using the correct login user name and password.
Water leaking into camera
housing.
• Ensure that the front glass cap and rear waterproof cap are
tightly secured. Loosening or removing the front and rear caps
will allow water to enter the housing.
Power supply is unstable.
• The operating temperature range for the supplied power
adapter is approximately 32°F to 104°F (0°C to 40°C). Replace
with an industry-level power adapter if operating the camera in
temperatures below 32°F (0°C).
• Use of a UPS power supply is strongly recommended.
Embedded NVR Integration Capacity Matrix
Refer to the following table when integrating Performance Series IP cameras with Honeywell
Embedded NVRs.
Table A-1
Part No.
Embedded NVR Integration Matrix - Maximum Frame Rate and Resolution
HED1PR3
HED3PR3
HBD1PR1
HBD3PR1
HBD3PR2
H4D3PRV2
H4D3PRV3
HEN04111(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
25/30 fps @
1280×960
25/30 fps @
1920×1080
25/30 fps @
1920×1080
25/30 fps @
1920×1080
25/30 fps @
1920×1080
HEN04121(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
25/30 fps @
1280×960
25/30 fps @
1920×1080
25/30 fps @
1920×1080
25/30 fps @
1920×1080
25/30 fps @
1920×1080
HEN08121(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN08141(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN08161(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN16131(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN16161(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN04112(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN04122(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN08122(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
www.honeywell.com/security
Troubleshooting | 97
Table A-1
Embedded NVR Integration Matrix - Maximum Frame Rate and Resolution
HEN08142(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN08162(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN16132(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
HEN16162(X)
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1280×960
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
25/30 fps @
1920×1080
20 fps @
2304×1296
800-21358 - A - 10/2015
98 | Performance Series IP Camera Software Configuration Guide
www.honeywell.com/security
B
Camera Specifications
B
HED1PR3/HED3PR3 Ball Cameras
Table B-1
HED1PR3/HED3PR3 Specifications
Camera
Image Sensor
HED1PR3: 1/3″ 1.3 megapixel progressive scan CMOS
HED3PR3: 1/3″ 3 megapixel progressive scan CMOS
Max. Effective Pixels (H×V)
HED1PR3: 1280×960 (1.3 MP)
HED3PR3: 2304×1296 (3 MP)
Min. Illumination
HED1PR3: 0.08 lux @ F2.0 (Color)/0 lux (B/W with IR LEDs on)
HED3PR3: 0.045 lux @ F2.0 (Color)/0 lux (B/W with IR LEDs on)
Lens
Fixed, 2.8 mm @ F2.0
Horizontal Angle of View
HED1PR3: 89°
HED3PR3: 92°
Automatic Electronic Shutter 1/3–1/30000 s
S/N Ratio
>50 dB
IR Range
Up to 100 ft (30 m), depending on scene reflectance
Day/Night
Auto(ICR)/Color/BW
BLC/WDR
BLC/HLC/DWDR
White Balance
Auto/Manual
Gain Control
Auto/Manual
Noise Reduction
3D DNR
Motion Detection
Up to 4 areas
Privacy Masking
Up to 4 areas
Video
Compression
H.264/H.264H/H.264B/MJPEG
Frame Rate
HED1PR3: 25/30 fps @ 1280 ×960 (1.3 MP), 1280×720 (720p), 704×576/704×480 (D1),
352×288/352×240 (CIF)
HED3PR3: 20 fps @ 2304×1296 (3 MP); 25/30 fps @ 1920×1080(1080p), 1280×720 (720p),
704×576/704×480 (D1), 352×288/352×240 (CIF)
Bit Rate (H.264)
4–8192 kbps
800-21358 - A - 10/2015
100 | Performance Series IP Camera Software Configuration Guide
Table B-1
HED1PR3/HED3PR3 Specifications
Network
Ethernet
RJ-45 (10/100Base-T)
Supported Protocols
IPv4/IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, IGMP, RTSP, RTP, SMTP, NTP, DHCP, DNS,
PPPoE, DDNS, FTP, IP Filter, QoS
Compatibility
ONVIF Profile S, CGI
User Access
20 users max.
Mobile App
HonView Touch for iPhone, Android Phone and Tablet
General
Power Supply
12 VDC, PoE (802.3af)
Power Consumption
HED1PR3: 3.8 W max. (IR LEDs on)
HED3PR3: 3.7 W max. (IR LEDs on)
Operating Temperature Range
–22°F to 140°F (–30°C to 60°C)
Relative Humidity
10% to 100%, condensing
Ingress Protection Rating
IP66
Dimensions
4.25 × 3.31 in. (108 × 84 mm)
Weight
0.55 lb (0.25 kg)
Regulatory
FCC: Part 15B Class B
System Compatibility
HEN041**(X) H.264 4-Channel 1080p Embedded Network Video Recorder
HEN081**(X) H.264 8-Channel 1080p Embedded Network Video Recorder
HEN161**(X) H.264 16-Channel 1080p Embedded Network Video Recorder
Recommended Accessories HQA-WK Wall Mount for Dome and Ball Cameras
HBS2-BB Junction Box
www.honeywell.com/security
Camera Specifications | 101
HBD1PR1/HBD3PR1/HBD3PR2 Bullet Cameras
Table B-2
HBD1PR1/HBD3PR1/HBD3PR2 Specifications
Camera
Image Sensor
HBD1PR1: 1/3″ 1.3 megapixel progressive scan CMOS
HBD3PR1/HBD3PR2: 1/3″ 3 megapixel progressive scan CMOS
Max. Effective Pixels (H×V)
HBD1PR1: 1280×960 (1.3 MP)
HBD3PR1/HBD3PR2: 2304×1296 (3 MP)
Min. Illumination
HBD1PR1: 0.08 lux @ F2.1 (Color)/0 lux (B/W with IR LEDs on)
HBD3PR1: 0.045 lux @ F2.1 (Color)/0 lux (B/W with IR LEDs on)
HBD3PR3: 0.1 lux @ F1.4 (Color)/0 lux (B/W with IR LEDs on)
Lens
HBD1PR1/HBD3PR1: Fixed, 3.6 mm @ F2.1
HBD3PR3: Motorized focus/zoom, 2.8–12 mm @ F1.4
Horizontal Angle of View
HBD1PR1: 71°
HBD3PR1: 81°
HBD3PR3: 86°–28°
Automatic Electronic Shutter HBD1PR1: 1/3–1/30000 s
HBD3PR1: 1–1/100000 s
HBD3PR3: 1/3(4)–1/100000 s
S/N Ratio
>50 dB
IR Range
Up to 100 ft (30 m), depending on scene reflectance
Day/Night
Auto(ICR)/Color/BW
BLC/WDR
BLC/HLC/DWDR
White Balance
Auto/Manual
Gain Control
Auto/Manual
Noise Reduction
3D DNR
Motion Detection
Up to 4 areas
Privacy Masking
Up to 4 areas
Video
Compression
H.264/H.264H/H.264B/MJPEG
Frame Rate
HBD1PR1: 25/30 fps @ 1280 ×960 (1.3 MP), 1280×720 (720p), 704×576/704×480 (D1),
352×288/352×240 (CIF)
HBD3PR1/HBD3PR2: 20 fps @ 2304×1296 (3 MP); 25/30 fps @ 1920×1080(1080p), 1280×720
(720p), 704×576/704×480 (D1), 352×288/352×240 (CIF)
Bit Rate (H.264)
4–8192 kbps
Local Storage
HBD3PR2: microSD, 128 GB max.
Network
Ethernet
RJ-45 (10/100Base-T)
Supported Protocols
IPv4/IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, IGMP, RTSP, RTP, SMTP, NTP, DHCP, DNS,
PPPoE, DDNS, FTP, IP Filter, QoS
Compatibility
ONVIF Profile S, CGI
User Access
20 users max.
Mobile App
HonView Touch for iPhone, Android Phone and Tablet
800-21358 - A - 10/2015
102 | Performance Series IP Camera Software Configuration Guide
Table B-2
HBD1PR1/HBD3PR1/HBD3PR2 Specifications
General
Power Supply
12 VDC, PoE (802.3af)
Power Consumption
HBD1PR1: 4.8 W max. (IR LEDs on)
HBD3PR1: 4.7 W max. (IR LEDs on)
HBD3PR2: 8.5 W max. (IR LEDs on)
Operating Temperature Range
–22°F to 140°F (–30°C to 60°C)
Relative Humidity
10% to 100%, condensing
Ingress Protection Rating
IP66
Dimensions
HBD1PR1/HBD3PR1: 6.5 × 2.76 in. (165.0 × 70.0 mm)
HBD3PR2: 8.46 × 3.56 in. (214.8 × 90.4 mm)
Weight
HBD1PR1/HBD3PR1: 0.84 lb (0.38 kg)
HBD3PR2: 1.43 lb (0.65 kg)
Regulatory
FCC: Part 15B Class B
System Compatibility
HEN041**(X) H.264 4-Channel 1080p Embedded Network Video Recorder
HEN081**(X) H.264 8-Channel 1080p Embedded Network Video Recorder
HEN161**(X) H.264 16-Channel 1080p Embedded Network Video Recorder
Recommended Accessories HBS2-BB Junction Box
www.honeywell.com/security
Camera Specifications | 103
H4D3PRV2/H4D3PRV3 Mini Dome Cameras
Table B-3
H4D3PRV2/H4D3PRV3 Specifications
Camera
Image Sensor
1/3″ 3 megapixel progressive scan CMOS
Max. Effective Pixels (H×V)
2304×1296 (3 MP)
Min. Illumination
H4D3PRV2: 0.1 lux @ F1.4 (Color)/0 lux (B/W with IR LEDs on)
H4D3PRV3: 0.1 lux @ F2.0 (Color)/0 lux (B/W with IR LEDs on)
Lens
H4D3PRV2: Motorized focus/zoom, 2.8–12 mm @ F1.4
H4D3PRV3: Fixed, 2.8 mm @ F2.0
Horizontal Angle of View
H4D3PRV2: 86°–28°
H4D3PRV3: 81°(55°)
Automatic Electronic Shutter H4D3PRV2: 1/3(4)–1/100000 s
H4D3PRV3: 1–1/100000 s
S/N Ratio
>50 dB
IR Range
Up to 100 ft (30 m), depending on scene reflectance
Day/Night
Auto(ICR)/Color/BW
BLC/WDR
BLC/HLC/DWDR
White Balance
Auto/Manual
Gain Control
Auto/Manual
Noise Reduction
3D DNR
Motion Detection
Up to 4 areas
Privacy Masking
Up to 4 areas
Video
Compression
H.264/H.264H/H.264B/MJPEG
Frame Rate
20 fps @ 2304×1296 (3 MP); 25/30 fps @ 1920×1080(1080p), 1280×720 (720p),
704×576/704×480 (D1), 352×288/352×240 (CIF)
Bit Rate (H.264)
4–8192 kbps
Local Storage
H4D3PRV2: microSD, 128 GB max.
Network
Ethernet
RJ-45 (10/100Base-T)
Supported Protocols
IPv4/IPv6, HTTP, HTTPS, TCP/IP, UDP, UPnP, ICMP, IGMP, RTSP, RTP, SMTP, NTP, DHCP, DNS,
PPPoE, DDNS, FTP, IP Filter, QoS
Compatibility
ONVIF Profile S, CGI
User Access
20 users max.
Mobile App
HonView Touch for iPhone, Android Phone and Tablet
800-21358 - A - 10/2015
104 | Performance Series IP Camera Software Configuration Guide
Table B-3
H4D3PRV2/H4D3PRV3 Specifications
General
Power Supply
12 VDC, PoE (802.3af)
Power Consumption
H4D3PRV2: 8.5 W max. (IR LEDs On)
H4D3PRV3: 4.7 W max. (IR LEDs On)
Operating Temperature Range
–22°F to 140°F (–30°C to 60°C)
Relative Humidity
10% to 100%, condensing
Ingress Protection Rating
IP66
Dimensions
H4D3PRV2: 4.8 × 3.5 in. (122 × 89 mm)
H4D3PRV3: 4.33 × 3.19 in. (110 × 81 mm)
Weight
H4D3PRV2: 1.1 lb (0.5 kg)
H4D3PRV3: 0.86 lb (0.39 kg)
Regulatory
FCC: Part 15B Class B
System Compatibility
HEN041**(X) H.264 4-Channel 1080p Embedded Network Video Recorder
HEN081**(X) H.264 8-Channel 1080p Embedded Network Video Recorder
HEN161**(X) H.264 16-Channel 1080p Embedded Network Video Recorder
Recommended Accessories HQA-WK Wall Mount for Dome and Ball Cameras
HQA-BB2 Junction Box
www.honeywell.com/security
Honeywell Security Products Americas (Head Office)
2700 Blankenbaker Pkwy, Suite 150
Louisville, KY 40299, USA
www.honeywell.com/security
 +1 800 323 4576
Honeywell Security Europe/South Africa
Aston Fields Road, Whitehouse Industrial Estate
Runcorn, WA7 3DL, United Kingdom
www.honeywell.com/security/uk
 +44 (0) 1928 754 028
Honeywell Security Products Americas
Caribbean/Latin America
9315 NW 112th Ave.
Miami, FL 33178, USA
www.honeywell.com/security/clar
 +1 305 805 8188
Honeywell Security Asia
35F Tower A, City Center, 100 Zun Yi Road
Shanghai 200051, China
www.asia.security.honeywell.com
 +86 21 2219 6888
Honeywell Security Middle East/N. Africa
Emaar Business Park, Sheikh Zayed Road
Building No. 2, Office No. 301
Post Office Box 232362
Dubai, United Arab Emirates
www.honeywell.com/security/me
 +971 (0) 4 450 5800
Honeywell Security Northern Europe
Ampèrestraat 41
1446 TR Purmerend, The Netherlands
www.honeywell.com/security/nl
 +31 (0) 299 410 200
Honeywell Security Deutschland
Johannes-Mauthe-Straße 14
72458 Albstadt, Germany
www.honeywell.com/security/de
 +49 (0) 7431 801-0
Honeywell Security France
Immeuble Lavoisier
Parc de Haute Technologie
3-7 rue Georges Besse
92160 Antony, France
www.honeywell.com/security/fr
 +33 (0) 1 40 96 20 50
Honeywell Security Italia SpA
Via della Resistenza 53/59
20090 Buccinasco
Milan, Italy
www.honeywell.com/security/it
 +39 (0) 2 4888 051
Honeywell Security España
Avenida de Italia, n° 7, 2a planta
C.T. Coslada
28821 Coslada, Madrid, Spain
www.honeywell.com/security/es
 +34 902 667 800
Honeywell Security Россия и СНГ
121059 Moscow, UI, Kiev 7
Russia
www.honeywell.com/security/ru
 +7 (495) 797-93-71
www.honeywell.com/security
+1 800 323 4576 (North America only)
https://www.honeywellsystems.com/ss/techsupp/index.html
Document 800-21358 – Rev A – 10/2015
© 2015 Honeywell International Inc. All rights reserved. No part of this publication may be reproduced by any means without written
permission from Honeywell. The information in this publication is believed to be accurate in all respects. However, Honeywell cannot
assume responsibility for any consequences resulting from the use thereof. The information contained herein is subject to change
without notice. Revisions or new editions to this publication may be issued to incorporate such changes.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising