Hydraulic Bollard - Titan
TITAN
TM
ANTI-RAM BOLLARDS
PRODUCT DETAIL SPECIFICATION
AMERISTARSECURITY.COM
| 866-467-2773
Section 1
Accreditation
1.01 Hydraulic bollard system
1.01.1
Designation – High Security Retractable Bollard System
1.02 ST-STD-02.01, Rev A, January 2006
1.02.1
1.02.2
1.02.3
1.02.4
Test Date January 30, 2006
Tested by KARCO Engineering, LLC
Test Location Adelanto, CA 92301
Certification Rating DOS K12/L3
1.03 Test Vehicle
1.03.1
1.03.2
1.03.3
1.03.4
1.03.5
1.03.6
1.03.7
Make/Type 1987 International S1600
GVW 15,056 Lbs.
Speed achieved 49.30 mph
Penetration -65mm or -2.56 inches
Engine running after test – NO
Vehicle drivable after impact – NO
Follow on vehicle could pass barrier – NO
1.04 Experience
1.04.1
Section 2
The Manufacturer shall have at least 100 similar systems installed and in operation.
General
2.01 Responsibilities
2.01.1
2.01.2
2.01.3
2.01.4
2.01.5
2.01.6
The manufacturer shall be responsible for furnishing each Titan vehicle barrier system and
associated equipment as specified.
The installer shall be responsible for furnishing installation materials, and providing installation,
and field testing of each anti-ramming Titan vehicle barrier system including the associated
equipment as specified.
The Owner/Operator (End User) or facility architect will assume responsibility of providing traffic and
safety engineering, including all necessary safety features to be used at each bollard site location,
including, but not limited to: sidewalks for pedestrian traffic, sufficient roadway lighting, caution
signage, traffic (stop) lights, audible warning alerts, visual warning alerts (such as flashing or
strobe lights), secondary traffic control devices (such as gate arms), security guard control points,
etc.
The Manufacturer shall supply a Titan vehicle barrier system including multiple bollard type barriers,
Hydraulic Power Unit (HPU), operator control panels, and accessories as specified.
The Manufacturer shall insure that the design and materials of the Titan vehicle barrier system are
the same as those used in the crash test of the barrier, and approved by the Department of State
(DOS).
The vehicle barrier system shall utilize multiple Titan electro hydraulic, retractable, round column
bollards.
Rev. 03/09/2015
Page 1 of 17
2.01.7
The installer shall install the Titan vehicle barrier system and shall consist of a minimum of three
bollards spaced no greater than 32 inches (813 mm) from centerline to centerline, across a roadway.
For roadways exceeding a 10 foot (3 meter) width, additional bollards shall be specified by the Buyer.
2.01.8 The Installer shall insure the Bollards are equally spaced across the roadway width for full protection
coverage.
2.01.9 Retaining walls, fixed bollards or other devices shall be provided by the installer or facility architects
on either side of the bollard set, to prevent vehicles from going around the bollards
2.01.10 The Buyer, in conjunction with the Owner/Operator (End User) requirements, will provide the
manufacturer with a written sequence of operation.
2.01.10.1 Sequence of operation will include but not limited to: the vehicle barrier system sequencing, vehicle
loop detector functions, gate arm functions, traffic lights, annunciators and all other equipment
directly controlled by the system.
2.01.10.2
If the written sequence of operation is not provided by Buyer, then the manufacturer shall supply a
default PLC program for basic Titan vehicle barrier system operation only. Additional sequences or
functions requested by the Buyer beyond the basic default functions are to be provided by the
manufacturer upon written request only and at additional fees to the Buyer. (PLC Only)
2.02 Quality Assurance
2.02.1
2.02.2
2.02.3
The manufacturer shall be a company specializing in the supply of vehicle barrier systems with a
minimum of 10 years’ experience.
The manufacturer shall provide a complete Titan vehicle barrier system that has been fabricated,
assembled and tested for proper operation prior to shipment.
The manufacturer shall have performed an actual crash test on the type of vehicle barrier system
being provided.
2.03 Submittals
2.03.1 The manufacturer shall submit to the Buyer drawings on the Titan vehicle barrier system.
Detail drawings shall show the top assembly layout and overall dimensions of each major element of
2.03.1.1
the barrier system equipment, including the bollards, HPU and operator control panels.
2.03.1.2
Detail drawings shall show the foundation and anchoring requirements of the Titan vehicle barrier
system equipment.
2.03.1.3
2.03.1.4
2.03.1.5
Detail drawings shall show the layout of a typical Titan vehicle barrier system.
2.03.1.6
A detailed electrical schematic including associated wiring shall be provided showing all electrically
connected components, including the interface points for connection to equipment.
2.03.1.7
The schematic drawings shall represent the entire Titan vehicle barrier system, with all
manufacturer supplied equipment connected and integrated together as a system.
2.03.1.8
Detail interconnect drawings shall show the minimum conduit size and number of wires required to
run between each of the barrier system equipment.
A detail hydraulic schematic drawing shall be provided.
A drawing shall be provided showing the size and number of hoses required to run between the
bollards and HPU. (Hose length to be determined and provided by installer)
Rev. 03/09/2015
Page 2 of 17
2.03.2
The manufacturer shall submit to the Buyer a crash test certification on the Titan vehicle barrier
system
A copy of the DOS crash rating letter, certifying the manufacturer’s barrier shall be provided. As an
2.03.2.1
alternate, the manufacturer may submit the current DOS website address listing the barrier system
certified crash rating.
2.03.2.2
If an Engineered system is provided a certificate of conformance that the Titan vehicle barrier
system delivered conforms to the crash rating, performance and the requirements of this
specification.
2.03.2.3
The manufacturer shall submit to the buyer a complete list of equipment, materials, including the
manufacturer's descriptive data and technical literature, catalog cuts, and installation instructions.
As well as Nameplate data which shall be permanently attached to each Titan vehicle barrier and
power unit. The data shall be legibly marked on corrosion-resistant metal plates and shall consist of
the following:
Manufacturer Name – Ameristar Security Products
Model Number – Titan Series
Serial Number – (TBD)
Type of barrier – Hydraulic, Manual, Fixed, Electric
Date of manufacture – (TBD)
2.03.2.4
The manufacturer shall submit to the buyer a typical bill of material (BOM) and spare parts data for
each different item of material and equipment used.
2.03.2.5
The Buyer will distribute Titan vehicle barrier system submittal documentation and drawings to the
Owner/Operator (End User), as necessary.
2.04 Final Documentation
2.04.1
After completion of field tests the Installer shall provide to the Manufacturer up-dated Red-lined
drawings, conforming to the “as-built” equipment provided.
2.04.2 After completion of field tests the manufacturer shall provide to the Buyer a comprehensive parts
and component documentation on the Titan vehicle barrier system, that conforms to the “as-built”
equipment provided.
A Parts List, or Bill of Material, shall be provided on all major parts and components used in the
2.04.2.1
Titan vehicle barrier system.
2.04.2.2
A recommended Spare and Consumables Parts List shall be provided. Spare parts shall be those
that can be field replaced. Consumables shall include items frequently required for maintenance
and service, such as, but not limited to: lights, fuses, lubricants, hydraulic fluid, filter elements, etc.
All items shall be provided with a part number, recommended quantity, and a brief description of the
item, with current unit prices and source of supply.
Rev. 03/09/2015
Page 3 of 17
2.04.3
After completion of field tests, the manufacturer shall submit to the Buyer an Operation and
Maintenance (O&M) Manual.
A Preface section, with the manufacturer’s name, model number and service contact information.
2.04.3.1
2.04.3.2
A Safety Warnings and Cautions section applicable during operation, maintenance, service and/or
repair.
2.04.3.3
An overview and general description of the Titan vehicle barrier system, including all equipment
provided, and a summary of features or characteristics.
2.04.3.4
2.04.3.5
2.04.3.6
A complete drawing package of the barrier system ordered.
A theory of operation, for both the hydraulic and electrical circuits.
An Operating Instructions section, including as a minimum procedures for system start-up, bollard
operation, shut down and manual operation.
2.04.3.7
A Maintenance Instructions section, including as a minimum routine maintenance requirements, a
chart of periodic maintenance activities and intervals, lubrication instructions and component
adjustment.
2.04.3.8
2.04.3.9
A Troubleshooting section, with probable cause and an itemized list of equipment checks.
A Reference Information section, including abbreviations and acronyms, torque values and a list of
applicable bollard drawings and documentation.
2.04.4
After completion of performance verification tests the installer shall submit to both the Buyer and
manufacturer a Titan vehicle barrier system PVT Report.
Upon completion and testing of the installed Titan vehicle barrier system, a Test Report shall be
2.04.4.1
submitted showing both the test data and results of any field tests, including the demonstration and
compliance with the specified performance criteria of this specification.
2.04.4.2
Each test report shall indicate the final position of component adjustments and set points.
2.04.5 The Buyer will distribute Titan vehicle barrier system final documentation and drawings to the
Owner/Operator (End User), as necessary.
2.05 Delivery, Storage & Handling
2.05.1
All equipment shall be prepared and protected by the manufacturer to be shipped by conventional
shipping methods.
2.05.2 The Titan vehicle barrier system equipment shall be protected by suitable methods for the intended
shipping and storage environments.
Packaging, preservation, pallets and crating shall prevent mechanical damage to the equipment
2.05.2.1
during both shipping and handling.
2.05.2.2
Forklift provisions (min 10,000 pound capability) shall be provided for the lifting and handling of
equipment.
2.05.2.3
2.05.2.4
Shipping containers and crates shall be identified with the type of equipment.
Shipping documents shall be provided with the contents of each container or crate.
Rev. 03/09/2015
Page 4 of 17
2.05.3
Equipment received on-site shall be placed in a storage area that is protected from the weather,
humidity, excessive temperature variation, dust, dirt and/or other contaminants.
Equipment shall be stored covered.
2.05.3.1
2.05.3.2
Both equipment and structural materials shall be stored on pallets.
2.05.3.3
Equipment shall not be stored directly on the ground, and shall be protected from standing water,
and other conditions that might cause rust or corrosion.
2.05.3.4
Equipment shall be stored in an area that is not subjected to potential damage by other construction
activities.
2.06 Warranty
The Titan Bollard system by Ameristar® is manufactured from the highest quality materials by skilled
craftsmen to meet the highest standards of workmanship in the industry. Ameristar warrants its Titan
Bollard system against defects in material and workmanship for a period of 1 year from the date of
substantial completion, or 1.5 years from the date of shipment. Barrier warranty requires that the
requirements and instructions described in the operation and maintenance manual be followed and
records of all maintenance activities be kept. Records should be available upon request and may be
required for warranty claims.
Should the barrier fail in accordance with the details described herein, Ameristar warrants to the original
purchaser their redemption through replacement, renewal or issuance of a pro-rated credit. Notice of
failure under the conditions of this warranty shall be sent to Ameristar or its authorized representative, in
writing, together with proof of purchase and shall specify the nature of the defect and when it was first
observed. Documented authorization from Ameristar must be received prior to performing any repair,
modification, or part replacement, which may be considered under warranty, or deemed necessary for
normal system functionality, failure to do so may void warranty in total.
Should the barrier be improperly installed, Ameristar shall not be responsible for guaranteed performance
or appearance of barrier. Failure to install barrier with a professionally licensed and manufacturerapproved installer shall negate warranty.
Warranty does not apply when failure or damage is due to improper use or application, abuse or misuse,
vandalism, natural disasters/catastrophes, or if products have been altered or modified, subjected to
improper storage, improper maintenance, negligence, or used with parts not authorized by the
manufacturer including but not limited to: excessive vehicle speed, excessive vehicle weight, temperature
extremes, long term flooding or lack of drainage, packed debris, snow or ice under the barrier, improper
electrical power feed voltage or frequency.
This warranty excludes wear, scratches and/or other damage to finishes and painted surfaces due to
normal use. The manufacturer shall not be liable for damage to the product which results in the use of
the barrier as a protective device (i.e. sustains a vehicle crash), due to damage caused by any other
vehicle contact when the barrier is not in the active barrier position, and/or due to damage caused by
snow plow operations. The manufacturer shall not be liable for any special, incidental or consequential
damages, which result from the use of the products by Buyer, Owner/Operator (End User) and/or any other
party, and limits the liability to the amounts paid by Buyer for the Product.
Rev. 03/09/2015
Page 5 of 17
Ameristar reserves the right to inspect the material to determine validity of the claim. Upon validation of
the claim by Ameristar or its authorized representative, redemption by replacement, renewal or issuance of
a pro-rated credit shall be made by Ameristar. If a warranty claim does not meet the warranty criteria,
then the Buyer or Owner/Operator (End User) shall be responsible for reimbursing the manufacturer for
service and/or repair costs. This warranty may exclude any on-site labor, travel costs to site and/or
expenses in performing service or repair on-site and freight charges, for valid warranty claims.
Equipment and components that are not manufactured by Ameristar shall be subject to the original
manufacturer’s specified warranty.
The above constitutes the complete warranty by the manufacturer. No other agreement, written or implied,
is valid. Ameristar does not authorize any other person or agent to make any other express warranties.
Ameristar neither assumes nor authorizes any other person or agent to assume any other liability in
connection with the barrier. Some jurisdictions do not allow limitations on how long an implied warranty
lasts, nor do they allow an exclusion or limitation of incidental or consequential damages; therefore, the
limitations and exclusions noted herein may not apply.
Rev. 03/09/2015
Page 6 of 17
Section 3
System Configuration
3.01 Bollards
3.01.1
3.01.2
3.01.3
3.01.4
3.01.5
Minimum of a 3 bollard array for a certified product
Diameter equal to 10.75 in (273 mm)
As Tested Height from top of grade level to top of bollard equal to 38 in (965 mm) The Titan Bollard
array was tested without the ¾” thick 16” diameter top hat. With this Hat installed the Height from
top of grade level to top of bollard is equal to 39 in (991 mm)
Spacing from bollard center to bollard center equal to 32 in (813 mm)
The clear opening from bollard to bollard equal to 22.25 in (565 mm)
3.02 Finish
3.02.1 The bollards and casing shall be protected from the effects of long term corrosion.
All bollard casings shall be hot dipped galvanized.
3.02.1.1
3.02.1.2
The bollard shall be painted with an exterior grade, standard black color.
3.02.1.3
When an alternate color is required, the Buyer will specify the custom color to the manufacturer at
the time of ordering.
3.03 Foundation
3.03.1
3.03.2
3.03.3
3.03.4
3.03.5
3.03.6
The foundation can be free formed to local soil.
Excavation Depth equal to 69 in (1753 mm)
Width front to back equal to 72 in (1829 mm)
Length of 3 bollard array equal to 120 in (3048 mm)
Concrete strength minimum of 3000 psi concrete must be used
Soil Compaction of not less than 95% maximum dry density
3.04 Bollard Performance & Parameters
3.04.1
When in the lowered position the bollard shall extend no more than 0.5 inch (13 mm) above the
roadway surface.
Rev. 03/09/2015
Page 7 of 17
3.04.2
The bollards, when in the lowered position, shall be capable of supporting a 32,000 pound (14,515
kg) Axle load or a 16,000 pound (7255 kilogram) wheel load. The Owner/Operator (End User) shall be
responsible for providing and posting weight limit signage to prevent bollard damage due to
excessive vehicle weight, in accordance with AASHTO HB-17.
3.04.3 Vehicle speed over bollards shall be rated for speeds up to, but not exceeding 20 mph. The
Owner/Operator (End User) shall be responsible for providing and posting speed limit signage to
prevent bollard damage due to excessive vehicle speed.
3.04.4 The bollard column shall not require lubrication.
3.04.5 The hydraulic cylinder shall be capable of being removed without requiring removal of the bollard
column.
3.04.6 The bollard column shall be capable of being removed without requiring removal of the hydraulic
cylinder, including associated hydraulic hoses.
3.04.7 The bollard shall be provided with road surface top plates, suitable for vehicle traffic. The road
surface top plates shall be constructed of steel plate, provided with an anti-skid surface, and shall
be replaceable.
3.04.8 The bollard shall be capable of being installed using an excavation depth not exceeding 69 inches
(1753 mm)
3.04.9 The bollards shall be capable of at least 120 complete up/down cycles per hour.
3.04.10 The bollard motion shall be instantly reversible in either direction.
3.04.11 The bollards shall rise in approximately 3-8 seconds, when operating at normal ambient temperature
conditions.
3.04.12 The bollards shall be capable of being lowered in not more than 3 seconds, when operating at
normal ambient temperature conditions.
3.04.13 The height of the bollards while raising and lowering is not required to be synchronized (i.e. the
heights are not required to match during movement).
3.04.14 The bollard shall be capable of operating in a temperature range of 50°F to 120°F (10°C to 48°C),
without heaters or heat exchangers. When the site ambient operating temperatures are not within
the standard operating temperature range, the Buyer shall specify cold temperature and/or hot
temperature operation.
3.04.15 The Titan vehicle barrier system shall provide two optional methods of operation, for use during
electrical power loss, or selected equipment failures:
3.04.15.1 Provide stored hydraulic pressure utilizing a hydro pneumatic accumulator, sized to allow no less
than a 1-cycle operation, on a fully charged system.
3.04.15.2 Provide an integrated, manual hand pump to permit rising and lowering of the bollards.
3.04.16 An Emergency Fast Operation (EFO) function is optional and can be provided which is capable of
raising the bollards to the full guard position in no greater than 1.5 seconds.
Rev. 03/09/2015
Page 8 of 17
Section 4
Hydraulic (HPU), Electric
4.01 HPU & Hydraulics
4.01.1
A Hydraulic Power Unit (HPU) shall be provided for supplying hydraulic fluid power to raise and lower
the bollards.
4.01.2 The HPU shall be remotely located at a standard maximum distance of 100 feet (30.5 meters) from
the bollards. Any distance greater than 100 feet (30.5 meters) must be approved by the
manufacturer.
4.01.3 The Installer shall provide hydraulic hoses between the HPU and each bollard hydraulic cylinder. Due
to the uncertainties in exact hose length, the installer shall supply the hoses rather than the bollard
manufacturer, to the site specific requirements. Hydraulic hoses shall be:
Rated to no less than 3000 PSIG (20.7 Mpa) by the hose manufacturer. The hose manufacturer’s
4.01.3.1
factor of safety shall be no less than 4:1 for this rating, with a burst pressure of at least
12,000 PSIG (82.8 Mpa).
4.01.3.2
Provided with protective wear sleeves at the bollard, to protect the hydraulic hoses from abrasion
and other mechanical damage.
4.01.3.3
Configured using two different sizes, including connections at the bollard hydraulic cylinder, to
eliminate the possibility of inadvertently connecting the hoses backwards.
4.01.4
4.01.5
4.01.6
Hydraulic component connections shall utilize all O-ring boss seal connections and fittings.
Hydraulic Hose connections shall utilize JIC connections and fittings
If required, the HPU and hydraulic circuit shall use an environmentally friendly hydraulic fluid which
does not degrade over time. Standard petroleum based hydraulic fluids are permitted if the
installation site is not environmentally sensitive. Vegetable based oil with limited shelf shall not be
used.
4.01.7 The HPU reservoir shall:
Be a standard reservoir design conforming to hydraulic industry standards.
4.01.7.1
4.01.7.2
Be a vertical mount reservoir with lift off lid for maintenance, and can be provided with an optional
filtered filler/breather.
4.01.7.3
Have a capacity to allow the full charging of accumulators, with a safety margin, to prevent
cavitation of the pump.
4.01.8
Based on number of bollards, duty cycle, and number of accumulators provided, the HPU shall be
provided with one of the following tank sizes: 10 Gallons (37.8l), or 26 Gallons (98.4 l). The
manufacturer shall determine the proper configuration and tank size.
4.01.9 The HPU shall use SAE Straight Thread, O-ring boss seals for tubing connections, to minimize
hydraulic fluid leakage, and no pipe threads shall be used.
4.01.10 The HPU shall use standard industrial components, which conform to hydraulic industry standards,
and have interchangeable mounting dimensions.
4.01.11 The majority of hydraulic components shall be manifold mounted to minimize connection points,
hydraulic leakage and permit component replacement without requiring the removal of other
hydraulic components. The use of in-line valves alone shall not be used.
4.01.12 The pump/motor shall be mounted, using male/female spline shafts.
Rev. 03/09/2015
Page 9 of 17
4.01.13 The HPU shall be covered and shielded from direct exposure to weather, direct sunlight and
associated environmental elements. The HPU shall be covered with a weather resistant enclosure, or
placed in a facility equipment room.
4.01.13.1 The HPU weatherproof enclosure shall be a powder coat painted, sheet metal enclosure.
4.01.13.2 The HPU weatherproof enclosure shall be provided with locking hinged doors for normal maintenance
and service access.
4.01.14 The HPU electrical motors driving the hydraulic pumps shall run at speed of less than 1800 RPM, for
lower noise emission, and longer pump/motor life.
4.01.15 The HPU electrical motors shall have a sufficient horsepower rating to operate the hydraulic pump at
the combined full rated flow and pressure, within the motor’s nameplate rating.
4.01.16 Based on required cycle duty of the bollards, the HPU shall be provided with one of the following
horsepower configurations: 2hp, or 5hp, the manufacturer shall determine the proper configuration
and horsepower rating for the Titan vehicle barrier system.
4.01.17 All control valves for bollard operation shall be provided as hydraulic solenoid poppet valves.
Solenoid valves shall be:
4.01.17.1 Provided with international, industry standard, sealed DIN connectors, on flexible cable assemblies.
Solenoid coil wiring shall be configured so that the connection does not need to be unwired when
replacing a valve. Solder connections, crimped ring lugs and wire nuts shall not be used.
4.01.17.2
Manifold or sub plate mounted, for superior sealing, and ease of replacement. Hydraulic lines shall
be configured so that they do not need to be removed when replacing a valve.
4.01.17.3
Provided with electrical surge suppression at the solenoid coils, for long-term reliability of electrical
switching controls (contacts).
4.01.17.4
Provided with LED indicators at the valve, to indicate if the solenoid is energized or de-energized, to
aid during troubleshooting and when performing fault diagnostics.
4.01.17.5
A spring return to a fail-safe position. Fail safe position shall default to a known safe state during
the start-up of equipment and after valve replacement. Detented type valves which can cause
unintended motion of the Titan vehicle barrier system shall not be used.
4.01.18 Optional HPU monitoring, indication and shutdown shall be provided.
4.01.18.1 Low hydraulic fluid level switch shall be provided to indicate insufficient hydraulic fluid in the
reservoir. OPTIONAL
4.01.18.2
High hydraulic fluid temperature switch shall be provided to indicate a hydraulic fluid over
temperature condition. OPTIONAL
Rev. 03/09/2015
Page 10 of 17
4.02 Electrical
4.02.1
The Titan vehicle barrier system shall operate on a standard 208-240 VAC, 3-Phase, 60 Hertz
electrical power feed. When the standard electrical power feed is not available, the Buyer will
specify an alternate electrical power feed to the manufacturer at the time of ordering. Note: Single
phase facility power will limit the installed system horsepower.
4.02.1.1
Optional – Electrical power voltages which may be factory configured are as follows:
Description
Conductors
Voltage
Frequency
Single Phase
2 Wire w/neutral
120 VAC
60 HZ
Single Phase
2 Wire wo/neutral
208 – 240 VAC
60 HZ
3 Phase
3 Wire wo/neutral
460 - 480 VAC
60 HZ
4.02.1.2
Optional – Electrical power frequency may be factory configured for 50 Hz electrical service.
4.02.2 The site facility shall provide a main power disconnect, circuit protection (such as a circuit breaker
or fusible disconnect) and utility electrical power feed wiring, for connection to the Titan vehicle
barrier system HPU electrical enclosure, sump pumps, bollard heaters, electric gate arms and/or
other equipment as required.
4.02.3 All voltages required by electrical circuits other than the main electrical power feed, shall be
provided by additional electrical circuit components, such as control transformers and DC power
supplies.
4.02.4 All electrical circuits shall be provided with overload and short circuit protection.
The main incoming electrical power feed shall be provided with a circuit breaker. BY SITE
4.02.4.1
INSTALLERS.
4.02.4.2
Each motor starter shall be provided with overload relays.
4.02.5 Electrical controls shall be provided integral to the HPU, with self-contained wiring to all mounted
components. Field wiring requirements shall be minimized.
4.02.6 Electrical controls shall be enclosed in an integral, sealed, NEMA 12,3R, 4, or 4X (or IP 65
equivalent) enclosure, for protection of electrical switchgear from moisture and weather conditions.
4.02.7 Electrical controls such as circuit breakers, fuses, terminal blocks, power supply, motor starter,
relays and PLC shall be DIN rail mounted for ease of replacement.
4.02.8 The electrical enclosure shall be mounted integral to the HPU, and located up front where accessible
from the weather proof enclosure hinged maintenance access door.
4.02.9 The enclosure internal wiring shall be provided in easy to access wiring raceways, with removable
raceway covers.
4.02.10 The electrical enclosure shall have additional space inside for DIN rail mounted accessories, such as
traffic light relays, heater contactors, and vehicle loop detector modules.
4.02.11 All high voltage electrical switchgear shall be mounted inside the electrical enclosure (including, but
not limited to: motor starters, heater contactors, etc.).
4.02.12 Electrical switchgear components shall be either UL and/or CE labeled.
Rev. 03/09/2015
Page 11 of 17
4.02.13 When site ambient operating temperatures will be below 50°F (10°C), the Buyer will specify the
lowest anticipated on-site ambient temperature condition to the manufacturer at the time of
ordering.
4.02.13.1 When cold temperature operation is specified by the Buyer, the manufacturer shall then provide HPU
reservoir and bollard heaters for both HPU and bollard operation.
4.02.13.2
When cold temperature operation is specified by the Buyer, the installer shall provide electrical
circuit breakers, switchgear and controls for operating the bollard heaters, and hose heating
(if required).
4.02.13.3
When cold temperature operation is specified by the Buyer, the installer shall provide additional
electrical wiring for the bollard heaters, and hose heating (if required).
4.02.14 When site ambient operating temperatures will exceed 120°F (48°C) requiring high temperature
operation, the Buyer will specify the highest anticipated on-site ambient temperature condition to
the manufacturer at the time of ordering.
4.02.14.1 When high temperature operation is specified by the Buyer, the manufacturer shall then provide an
air-conditioning unit to maintain the hydraulic fluid at acceptable temperature levels during HPU
and bollard operation.
4.02.14.2
When high temperature operation is specified by the Buyer, the manufacturer shall provide electrical
switchgear and controls (as required) for operating a circulation pump motor and the airconditioning unit.
Rev. 03/09/2015
Page 12 of 17
Section 5
System Controls
5.01 Type 1 PLC System:
5.01.1
Shall have electrical controls and monitoring programmable, utilizing either a ruggedized, industrial
type Programmable Logic Controller (PLC).
The PLC shall be a standard commercial, off the shelf PLC, and shall not use “custom” sole source
5.01.1.1
printed circuit type control boards.
5.01.1.2
The PLC shall be microprocessor based, to permit programming of the Titan vehicle barrier system
control and monitoring functions.
5.01.1.3
Control and monitoring functions for the control circuit shall function through the PLC.
5.01.1.4
The PLC shall utilize solid state electronic input switching for high reliability.
5.01.2 Shall have HMI interface screen integrated into the PLC.
5.01.3 Shall be NEMA 4 and door mounted on circuit enclosure panel
5.01.4 Shall have FREE downloadable software which does not require licensing agreements.
5.01.5 Have easy to replace I/O modules. Modules shall utilize removable terminal strips and be capable of
replacement without disturbing wiring. The PLC shall utilize I/O module slots for expandable I/O. The
PLC shall be capable of being programmed by factory trained and authorized technicians.
The PLC programming shall allow simplified configuration of controls and monitoring to suit specific
5.01.5.1
on-site conditions. Hard-wired control relays alone shall not be used.
5.01.5.2
The PLC programming shall be capable of being field reprogrammed on-site, utilizing a standard
laptop PC, with Windows based programming software. Software shall be in an industry standard
programming format. A proprietary programming language or use of machine code shall not be
used. The PC, programming cable and programming software are not deliverable items with the
vehicle barrier system.
5.01.5.3
The PLC programming logic (code) and configuration for the Titan vehicle barrier system shall be
capable of being stored as an electronic file for re-load of the microprocessor in the future.
5.01.5.4
The PLC programming monitoring and troubleshooting shall be capable of being performed utilizing
a laptop computer, to aid in fault diagnostics.
5.01.6 Shall be able to update via micro SD card
5.01.7 Shall utilize Terminal blocks
Shall be PCB Style with screw terminations.
5.01.7.1
5.01.7.2
PCB’s shall be for hardware specific terminations (i.e. 3 wires of the down sensor)
5.02 Type 2 ACPCS Solution (PC Based)
5.02.1 Be a Standard off the shelf PC Solution utilizing a Windows OS (Win XP, 7 or 8)
5.02.2 Utilize a user friendly GUI Interface designed for ease of user configuration
Point and click programming allows for quick changes in the system
5.02.2.1
5.02.2.2
Allows for touch screen displays and functionality
5.02.2.3
Real time diagnostic of all I/O’s within the system (updated in 100ms increments)
5.02.3 Utilize microprocessor based control panels, to permit programming of Titan vehicle barriers
5.02.4 Control panels allow for seamless integration of
Rev. 03/09/2015
Page 13 of 17
5.02.4.1
Solid state Form C relay outputs with a varying range from 12-24VDC at 5 amps to 120VAC at 3amp
per output.
5.02.4.2
Supervised NO / NC programmable inputs.
5.02.4.3
Card reader connections – Supports Mag-stripe, Prox, RFID, Barcode, Weigand
5.02.4.4
Communications from TCPIP, RS-232, and RS-485
5.02.5 Shall allow for I/O Expansion from 62 inputs – 496 Inputs, 53 Output – 424 Outputs per system.
5.02.6 Shall allow for real time on-screen System event recording. (Updated in 100ms increments)
With programmable archiving and history retrieval
5.02.6.1
5.02.7 Shall allow for seamless integration of Intrusion detection Sensors
Sensors include, photo cells, ported coax, fiber optics, microwave, etc.
5.02.7.1
5.02.8 Shall allow for seamless integration of Access Control technologies
With built in personnel database for independent asset tracking
5.02.8.1
5.02.9 Shall allow for seamless integration of CCTV cameras up to 32 per system (analog and/or Digital)
With built in DVR functionality, as well as real time alarm tagging.
5.02.9.1
5.02.10 Shall allow for seamless integration of Wrong way and Over Speed detection (utilizing Doppler radar)
up to 8 Radar heads per system.
5.02.11 Shall allow for enterprise solution
5.02.11.1 Stand-alone system
5.02.11.2 Network multiple standalone system to a single monitoring facility
5.02.11.3 Has obtained DIACAPP Certified
5.02.12 Shall allow for mobile management VIA Motorola PDA
5.03 Controls General
5.03.1
All control and monitoring circuits, including signals, shall operate using low voltage, +24 VDC for
safety, outside of the main electrical enclosure. To minimize the possibility of electrical noise, AC
voltage signals shall not be used (PLC Only). This requirement is not applicable to the ACPCS
System, electric motor electrical power, sump pumps, bollard heaters, electric gate arms and/or
other equipment as required.
5.03.2 The control circuit shall have additional optional interfaces with auxiliary equipment for control and
monitoring such as: card readers, loop detectors, traffic lights, etc. made possible through
connection to a main terminal strip.
5.03.3 Proximity switches shall be provided for monitoring the bollard raised/lowered position. The
proximity switches shall be:
Shock resistant, and use an electronic, solid state construction. The non-contact type sensor shall
5.03.3.1
have no moving parts, and shall not be sensitive to adjustment and/or affected due to the bollard
movement or stopping.
5.03.3.2
Resistant to water and shall be capable of being submerged (i.e. due to rain water, melting snow,
wash down, etc.).
5.03.3.3
Provided with a connector, so that the switch can be easily disconnected, without requiring the
removal of wiring.
Rev. 03/09/2015
Page 14 of 17
5.03.3.4
Provided with an LED indicator, to provide a visual indication of the switch state (i.e. on or off) to
assist during adjusting, and also during troubleshooting. LEDs shall be visible from any angle.
5.03.3.5
Used at a low voltage signal level for safety (i.e. not high voltage).
5.04 Operator Control Panels
5.04.1
Operator control panels and associated control circuit shall be provided to interface between all
bollard locations, operator control panels and the HPU.
The Main Operator Control Panel shall be physically located at the site (such as a security room) to
5.04.1.1
allow operation of all bollards.
5.04.1.2
The Remote Operator Control Panels shall be physically located in close proximity to each set of
bollards, (such as a guard booth).
5.04.1.3
All operator control panels shall be mounted in an indoor, covered environment, and shall not be
exposed to weather and environmental conditions.
5.04.1.4
All operator control panels will be mounted in such way that the operator always has visual (eye or
camera) supervision on the barrier, when operating the barrier.
5.04.2
The control circuit shall be part of the PLC or ACPCS and associated equipment, integral with the
HPU electrical enclosure.
The control circuit functions and monitoring shall be programmed into the PLC or ACPCS.
5.04.2.1
5.04.2.2
The operator control panel switches and indicators shall interface with the PLC or ACPCS
Inputs/Outputs.
5.04.2.3
All operator control panel switches and indicators shall be pre-wired to wiring terminal strips. The
terminal strips shall provide an interconnection side to allow connection of site field wiring.
5.04.3
All operator control panel circuits, including signals, shall operate using low voltage, +24 VDC for
safety.
5.04.4 A Main Operator Control Panel shall be supplied for control and indication of all Titan vehicle barrier
system functions. The Default Main Operator Control Panel shall have:
5.04.4.1 A key lockable main Power On/Off switch (key switch), with an associated green color main power On/Off
5.04.4.2
5.04.4.3
5.04.4.4
5.04.4.5
indicator light.
A set of illuminated pushbuttons for Up/Down control, to raise and lower each set of bollards.
A set of Up/Down indicator lights for indicating the position of each set of bollards when in the full Up or
full down position. The Up indicator lights shall be red, and the down indicator lights shall be green.
The indicators lights shall be provided integral to the Up/Down illuminated pushbuttons switches.
A key lockable Arm/Disable switch to permit operation of each of the Remote Operator Control Panels in
the vehicle barrier system.
A red color illuminated switch for Emergency Fast Operate (EFO) to rapidly raise all bollards in the vehicle
barrier system. The EFO switch shall be provided with a transparent flip cover.
Rev. 03/09/2015
Page 15 of 17
5.04.4.6
Reset: A keyed switch for EFO Reset, to restore the vehicle barrier system to normal operation after
activating the EFO function.
5.04.4.7 An optional emergency stop switch to immediately stop the movement of the barrier in any position. The
button will be red, following safety standards. The emergency stop cannot be activated when the EFO is
active. EFO can be activated when emergency stop is active. OPTIONAL
5.04.4.8 Reset: A keyed switch for emergency stop Reset, to restore the vehicle barrier system to normal operation
after activating the emergency stop function.
5.04.4.9
A red color Check Oil indicator light for indicating a low level in the reservoir, or a hydraulic fluid
over temperature condition.
5.04.5
Custom Master Control panels can be built to conform to all site requirements, or to conform to the
ACPCS specification 34 41 26.00 10.
5.04.6 One or more Remote Operator Control Panels shall be provided for control and indication of each set
of bollards within the overall Titan vehicle barrier system. Each Default Remote Operator Control
Panel shall have:
5.04.6.1 A green color panel on indicator light for indicating the panel has been enabled for operation by the
5.04.6.2
5.04.6.3
5.04.6.4
5.04.6.5
5.04.6.6
5.04.6.7
5.04.6.8
5.04.6.9
5.04.7
5.04.8
5.04.9
remote armed key switch on the Main Operator Control Panel.
A set of illuminated pushbuttons for Up/Down control, to raise and lower each set of bollards.
A set of Up/Down indicator lights for indicating the position of each set of bollards when in the full Up or
full down position. The Up indicator lights shall be red, and the down indicator lights shall be green.
The indicators lights shall be provided integral to the Up/Down illuminated pushbuttons switches.
A key lockable Arm/Disable switch to permit operation of each of the Remote Operator Control Panels in
the vehicle barrier system.
A red color illuminated switch for Emergency Fast Operate (EFO) to rapidly raise all bollards in the vehicle
barrier system. The EFO switch shall be provided with a transparent flip cover.
Reset: A keyed switch for EFO Reset, to restore the vehicle barrier system to normal operation after
activating the EFO function.
An optional emergency stop switch to immediately stop the movement of the barrier in any position. The
button will be red, following safety standards. The emergency stop cannot be activated when the EFO is
active. EFO can be activated when emergency stop is active.
Reset: A keyed switch for emergency stop Reset, to restore the vehicle barrier system to normal operation
after activating the emergency stop function.
A red color Check Oil indicator light for indicating a low level in the reservoir, or a hydraulic fluid over
temperature condition.
Custom Remote, Overwatch, or Local controls panels can be built to conform to all site requirements,
or to conform to the ACPCS specification 34 41 26.00 10.
Operator control panel labeling shall use both text and graphic elements. A clear plastic overlay
shall be provided to protect the panel surface and labeling from normal usage, and occasional panel
cleaning.
Operator control panels shall be provided as a standard sloped, electrical enclosure console, suitable
for countertop mounting. When alternate industry standard 19 inch (483 mm) rack mount panels
are required in lieu of the consolet, the Buyer will specify the use of 19 inch (483 mm) panels to the
manufacturer at the time of ordering. Note: Only the panels are provided (i.e. the rack enclosure is
excluded).
Rev. 03/09/2015
Page 16 of 17
5.04.10 The operator control panels shall use electrical industry standard, industrial grade, electrical
components. Switches and indicators shall be no less than the 0.89 inch (22.5 mm) switch industry
standard size.
5.04.11 Electrical switch and indicator components shall be either UL and/or CE labeled.
5.04.12 Electrical switch and indicator components shall be mounted in a sealed, NEMA 1, 3 or 12 (or IP 64
equivalent) enclosure, for protection against moisture and weather conditions, excluding the 19 inch
(483 mm) panels.
5.04.13 All wiring to operator control panel components shall be terminated at terminal blocks, for ease of
on-site field interconnection with other vehicle barrier system equipment and accessories.
5.04.13.1 The terminal strips shall be standard high density, industrial grade, PCB style connectors for field
wiring, and screw type connectors for internal system wiring, and fixed count, ring lug type terminals
shall not be used.
5.04.13.2
Section 6
The terminal blocks shall be DIN rail mounted.
Products
6.01 Manufacturer and model procurement
6.01.1
The vehicle barrier system shall be a Titan Model active electro hydraulic, bollard type manufactured
by:
Ameristar Perimeter Security USA.
1555 N Mingo Road
Tulsa, OK, 74116
Phone: 918-835-0898
Fax: 918-835-1002
http://www.ameristarsecurity.com/
Rev. 03/09/2015
Page 17 of 17