RPL: WHR 7-1/2 to 120 Tons, Vintage C

RPL: WHR 7-1/2 to 120 Tons, Vintage C
Replacement Parts List No. 055224300
Revision H 12/2013
SeasonPak
Water Chillers
WHR 7-1/2 thru 120 Tons
Vintage C
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
Table of Contents
Parts List Revision History................................................................................................................... 3
Equipment Serial Number Nomenclature............................................................................................ 4
Electrical Components Legend............................................................................................................ 5
Power & Control Panel
WHR 008, 010, 015, 020, 025 & 030 - Schematic........................................................................... 6
WHR 008, 010, 015, 020, 025 & 030 - Power Panel / Components List......................................... 7
WHR 008, 010, 015, 020, 025 & 030 - Control Panel / Components List........................................ 8
WHR 040, 050 & 060 - Schematic................................................................................................... 9
WHR 040, 050 & 060 - Power Panel / Components List............................................................... 10
WHR 040, 050 & 060 - Control Panel / Components List.............................................................. 11
WHR 070, 080, 090, 110 & 120 - Schematic................................................................................. 12
WHR 070, 080, 090, 110 & 120 - Power Panel / Components List............................................... 13
WHR 070, 080, 090, 110 & 120 - Control Panel / Components List......................................... 14-15
Compressors
008C-060C / Components List....................................................................................................... 16
070C-120C / Components List....................................................................................................... 17
Miscellaneous Compressor & Mounting Vibration Isolation / Components List............................. 18
Unit Mounting Vibration
Isolator Selection & Mounting Locations
Arrangements 1 & 2................................................................................................................ 19
Arrangements 3 & 4................................................................................................................ 20
Single Rubber-in-Shear/Isolator .................................................................................................... 21
Spring-Flex Mountings/Isolator...................................................................................................... 22
Cooler Assembly
Arrangements 1, 2, 3 & 4 / Components List................................................................................. 23
Sub-Assembly Diagram................................................................................................................. 24
Sub-Assembly / Components List............................................................................................. 25,26
Condenser Section
Location - Arrangement 1 / Components List................................................................................ 27
Location - Arrangement 4 / Components List................................................................................ 28
Sub-Assembly Diagram................................................................................................................. 29
Sub-Assembly / Components List............................................................................................. 30-34
Piping & Miscellaneous
008C-030C / Components List.................................................................................................. 35,36
040C-060C / Components List....................................................................................................... 37
070C-090C / Components List....................................................................................................... 38
100C-120C / Components List....................................................................................................... 39
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 2
Parts List Revision History
RevisionDate
New
Description
4-89New
A
11-99
Reformatted for electronic version.
B
10/01
Page 35 & 37 - Added the work ‘PILOT’ to the heading**Solenoid Valve, Liquid LIne, 120 Volt.
C
6/02
Page 39 - Pressure relief valve, 450 PSI part number was incorrect as 039441302 and was changed to 039441300.
Pages 16, 17 - Removed all Copeland compressor information.
D
10/2004
E
4/2005
Page 16 - WHR-050C 35HP part # 023576600 was changed to part #023576900.
Page 35 -Solenoid Valve Liquid Line 30.5 Ton pn 025327510 changed to #025327500.
F
5/2007
Page 4- Added Model Number Nomenclature
G
3/2009
Page 33- Bub # 265 change gasket p/n from 021026100 to 021027100.
Bub # 266 change gasket p/n from 021026100 to 021027200.
H
12/2013 Pages 23-26: Added note to contact Daikin Applied for Cooler Assemblies and parts.
Page 33: Corrected part numbers for Cond Model 038911300 Ref. 265 & 266 to 021026100, were 021027100 & 021027200.
Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 3
Equipment Serial Number Nomenclature
Complete Equipment Serial Number Must Be Furnished on All Warranty Orders
Complete Serial Number
3 E B 12345 03 Engineering Revision
Plant Identification Number
1 = Minneapolis
3 = Faribault
4 = Grenada
5 = Staunton
7 = Spirit Lake / Auburn
Year Manufactured
A = 1971
H = 1978
B = 1972
J = 1979
C = 1973
K = 1980
D = 1974
L = 1981
E = 1975
M = 1982
F = 1976
N = 1983
G = 1977
P = 1984
Sequence Number
Month Manufactured
Q = 1985
R = 1986
S = 1987
T = 1988
U = 1989
V = 1990
W = 1991
X = 1992
A
B
C
D
E
F
G
H
J
K
L
M
Y = 1993
Z =
1994
=
=
=
=
=
=
=
=
=
=
=
=
January
February
March
April
May
June
July
August
September
October
November
December
W HR - 030 C - 1* Condensing Medium
Basic Unit *:
1 -With a Single Water Cooled
Condenser per Refrigerant
Circuit
Compressor Type
Nomnal Capacity (Tons)
2 - With Mounted Receivers(s) in
lieu of Condenser(s)
Vintage
3 -Less Condenser(s) or
Receiver(s)
4 -With Dual Water Cooled
Condensers per Refrigerant
Circuit
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 4
Electrical Components Legend
AB1....................................Alarm Bell
CB1 thru 4..........................Circuit Breakers
CCL1..................................Control Circuit Light
CL1 thru 4..........................Cooling Stage Lights
CTB....................................Terminal Block (Control)
F1.......................................Fuse, Control Circuit
FS1,2.................................Freeze Controls
FTB....................................Terminal Block (Field Control Wiring)
HP1,2.................................High Pressure Controls
HTR 1 thru 4......................Crankcase Heaters
LP1,2.................................Low Pressure Controls
MA, MB..............................External Starter Coils
M1 thru 8............................Contactors (Compressor 1,2,3,4)
NB......................................Terminal Block (Neutral)
OP1 thru 4.........................Oil Pressure Control (Compressor 1,2,3,4)
PB1....................................Terminal Block (Power)
PS1,2.................................Pumpdown Switches
R3,4...................................Starting Relays (Compressor 3,4)
R5,6,7,8.............................Compressor Lockout & Interlock Relays
R9,10.................................Low Ambient Start Relays
R11,12,13,14.....................Alarm & Safety Relays
R19,20...............................Low Pressure Relays
R19,20,21..........................Pump Starter Relays
S3......................................System Switch
S4,5...................................Lead-Lag Switches
SL1 thru 4..........................Compressor Circuit Safety Switches
SV1,2.................................Solenoid Valves
T1.......................................Control Circuit Transformer
T2.......................................Alarm Circuit Transformer
TC1....................................Water Temperature Control Thermostat
TD1 thru 4..........................Part Winding Time Delay Relays (Compr. 1,2,3,4)-Opt.
TD6 thru 8..........................Compressor Lockout Time Delay Relays (Compr. 1,2,3,4)-Opt.
TD9 &10.............................Low Ambient Start Time Delays-Optional
TD11-13.............................Compressor Sequencing Time Delays
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 5
Power & Control Panel
WHR-008, 010, 015, 020, 025 & 030 - Schematic
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 6
Power & Control Panel
WHR-008, 010, 015, 020,025 & 030 - Power Panel / Components List
Part
Number
Description
CB1
CB1
CB1
CB1
CB1
CB1
CB1
CB1
CB1
CB1
CB1
CB1
Circuit Breakers - 208/230V/60Hz/3Ph Unit Voltage
40 Amp, 240 Volt, 3 Pole - 7.5 hp Compressor Circuit
50 Amp, 240 Volt, 3 Pole - 10 hp Compressor Circuit
100 Amp, 240 Volt, 3 Pole - 20 & 25 hp Compressor Circuit
125 Amp, 240 Volt, 3 Pole - Units w/o Unit Mounted Condensers
(G.O. Code 08=Y) See Note 1.
125 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. High Pressure Cond.
(G.O. Code 08=B) See Note 1. 30 hp Compressor Circuit.
100 Amp, 240 Volt, 3 Pole - Units with Unit Mounted Std. Condensers
(G.O. Code 08=A) 30 hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units w/o Unit Mtd. Condensers.
(G.O. Code 08=Y) See Note 2. 35 hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. High Press. Condensers
(G.O. Code 08=B) See Note 2. 35 hp Compressor Circuit.
125 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. Std. Condensers
(G.O. Code 08=A) See Note 1. 35 hp Compressor Circuit.
Circuit Breakers - 460V/60Hz/3Ph or 380V/50Hz/3Ph Unit Voltage
25 Amp, 480 Volt, 3 Pole - 7.5 to 10 hp Compressor Circuit.
50 Amp, 480 Volt, 3 Pole - 20 & 25 hp Compressor Circuit.
70 Amp, 480 Volt, 3 Pole - 30 & 35 hp Compressor Circuit.
M1, M3
M1, M3
M1, M3
M1, M3
M1
M1
M1
M1
M1
Contactors - 208/230V60Hz/3Ph
Compressor 1
Compressor 1
Compressor 1
Compressor 1
M3
M3
M3
008C
010C
015C
020C
025C
030C
Schem.
Symbol
Unit Size
Pieces/Unit
022427410 1
022427411 1
022427413 1 1
043758901 1
043758901 1
022427413 1
043758902 1
043758902 1
043758901 1
022427404 1 1
047359328 1 1
047359329 1 1
40 Amp, 600 Volt, 3 Pole
50 Amp, 600 Volt, 3 Pole
60 Amp, 600 Volt, 3 Pole
75 Amp, 600 Volt, 3 Pole
027514103 1 2
027514104 1
027514105 2
027514106 2 2
Contactors - 460V/60Hz/3Ph or 380V/50Hz/3Ph
Compressor 1, Across-The-Line Start
24 Amp, 600 Volt, 3 Pole
Compressor 1, Across-The-Line Start
40 Amp, 600 Volt, 3 Pole
Compressor 1, Across-The-Line Start
50 Amp, 600 Volt, 3 Pole
Compressor 1, Across-The-Line Start
60 Amp, 600 Volt, 3 Pole
Compressor 1, Across-The-Line Start
75 Amp, 600 Volt, 3 Pole
027514101 1 1
027514103 1
027514104 1
027514105 1
027514106 1
Compressor 1, Part Winding Start
Compressor 1, Part Winding Start
Compressor 1, Part Winding Start
027514101 2 2
027514102 2
027514103 2
24 Amp, 600 Volt, 3 Pole
30 Amp, 600 Volt, 3 Pole
40 Amp, 600 Volt, 3 Pole
Notes:
1. Replaces obsolete part number 860-014143Y-00 (Heinemann No. CJ3G3U1251). When replacing old style circuit breaker with new style, mounting bracket 044342000 must be ordered (one per circuit breaker).
2. Replaces obsolete part number 860-182717C-01 (Heinemann No. CJ3G3U1501). When replacing old style circuit breaker with new style, mounting bracket 044342000 must be ordered (one per circuit breaker).
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 7
Power & Control Panel
WHR-008, 010, 015, 020,025 & 030 - Control Panel / Components List
Part
Number
Description
R5
R9
R11
R19
R21
TD1
Relays
3PDT, 120A, Compressor Lockout Relay
SPDT, 3A, Low Ambient Start Relay
3PDT, 120A, Alarm and Safely Relay
DPDT, 15A, Low Pressure Control Relay
3PDT, 120A, Water Pump Starter Relay
Time Delays
1 Second Part Winding Time Delay
TD5
TD9
FS1
OP1
HP1
LP1
TC1
300 Second Compressor Lockout Time Delay
165 Second Low Ambient Start Time Delay
Controls
Freeze Protection Control
Oil Pressure Control
High Pressure Control
Low Pressure Control
2-Stage Capacity Control Stat, Well Part Number 020325500
(Standard Capacity Control Arrangement) Code 06=1.
TC1
4-Stage Capacity Control Stat, Well Part Number 020325500
(Optional Capacity Control Arrangement) Code 06=2.
PS1
SPST, 6 Amp, Compressor Pumpdown Switch
S3
SPST, 20 Amp, Control System Switch
S1,CL1, Indicator Lights
White Neon
& CCL1 Indicator Lights
Red
F1
Fuse, 4 Amp, Control Circuit
Fuseholder, 15 Amp
F2 & Fuseholder, 30 Amp (Code 11=B or C)
F3
Fuse, 4 Amp, 208V (Code 04=12)
Fuse, 1.5 Amp, 460V (Code 04=27)
Fuse, 3 Amp, 230V (Code 04=29)
Terminal Blocks
FTB
Terminal Blocks, 14 Terminals, 20A, 300V, Field Control Terminal Block
CTB
Terminal Blocks, 30 Terminals, 20A, 300V, Control Terminal Block
NTB
Terminal Blocks, 7 Terminals, Neutral Bar Terminal Block
Control Circuit Transformer
T1
230/460-115V, .75 KVA Transformer (Code 04=27 or 29)
T1
208/277/380-115V, .75 KVA Transformer (Code 04=28)
Optional Alarm Bell (Code11=A)
24V Alarm Bell
T2
120-24V,.04 KVA, Transformer
Phase Voltage Monitor
Motor Saver (Phase Voltage Monitor)
460V
Motor Saver (Phase Voltage Monitor)
230V
Motor Saver (Phase Voltage Monitor)
208V
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
028814400
032508101
028814400
019643000
028814400
Unit Size
Pieces/Unit
008C
010C
015C
020C
025C
030C
Schem.
Symbol
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
028210101 1 1 1 1
028381900
032358500
1 1 1 1 1 1
1 1 1 1 1 1
001354800
001354900
001354400
001354500
017373800
111111
111111
111111
111111
1 1 1 1 1 1
027664200 1 1
001355000
024735200
016508304
016508303
018690700
018690600
047354101
046742214
046742209
046742212
1 1 1 1 1 1
1 1 1 1 1 1
333333
333333
1 1 1 1 1 1
111111
2 2 2 2 2 2
2 2 2 2 2 2
2 2 2 2 2 2
2 2 2 2 2 2
022431214
015998130
037530800
1 1 1 1 1 1
1 1 1 1 1 1
1 1 1 1 1 1
038253905
038253914
1 1 1 1 1 1
1 1 1 1 1 1
017809400 111111
017503800 111111
039444703
039444702
039444701
Rev. H 12/2013
RPL 055224300 / Page 8
Power & Control Panel
WHR-040, 050, 060 - Schematic
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 9
Power & Control Panel
WHR-040, 050, 060 / Power Panel - Components List
CB1,
CB2
CB1,
CB2
CB1,
CB2
CB1,
CB2
060C
Circuit Breakers - 208/230V/60Hz/3Ph Unit Voltage
100 Amp, 240 Volt, 3 Pole - Units with Std. Condensers
022427413
2
1
(G.O. Code 08=A) 25 hp Compressor Circuit.
125 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. Std. Condensers
043758901
1
2
(G.O. Code 08=A) See Note 1. 35 hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units w/o Std. Condensers
043758902
1
2
(G.O. Code 08=Y) See Note 2. 35 hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. High Press. Condensers 043758902
1
2
(G.O. Code 08=B) See Note 2. 35 hp Compressor Circuit.
Circuit Breakers - 460V/60Hz/3Ph or 380V/50Hz/3Ph Unit Voltage
CB1,
50 Amp, 480 Volt, 3 Pole - 25 hp Compressor Circuit.
CB2
75 Amp, 480 Volt, 3 Pole - 35 hp Compressor Circuit.
Contactors - 208-230V/60Hz/3Ph
M1, M2 60 Amp, 600 Volt, 3 Pole, 25 hp Compressor Circuit
M3,M4 75 Amp, 600 Volt, 3 Pole, 35 hp Compressor Circuit
M1, M2
M1, M2
M3,M4
050C
Part
Number
Description
040C
Schem.
Symbol
Unit Size
Pieces/Unit
047359328
2
047359329
1
1
2
027514105
4
027514106
2
2
4
Contactors - 460V/60Hz/3Ph, Across-The-Line Start
50Amp , 600 Volt, 3 Pole, 25 hp Compressor Circuit
75Amp, 600 Volt, 3 Pole, 35 hp Compressor Circuit
027514104
2
027514106
1
1
2
Contactors - 460V/60Hz/3Ph, Part Winding Start
25Amp , 600 Volt, 3 Pole, 25 hp Compressor Circuit
40Amp, 600 Volt, 3 Pole, 35 hp Compressor Circuit
027514101
4
027514103
2
2
4
Notes:
1. Replaces obsolete part number 860-014143Y-00 (Heinemann No. CJ3G3U1251). When replacing old style circuit breaker with new
style, mounting bracket 044342000 must be ordered (one per circuit breaker).
2. Replaces obsolete part number 860-182717C-01 (Heinemann No. CJ3G3U1501). When replacing old style circuit breaker with new
style, mounting bracket 044342000 must be ordered (one per circuit breaker).
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 10
Power & Control Panel
WHR-040, 050, 060 / Control Panel - Components List
Relays
3PDT, 120A, Compressor Lockout Relay
SPDT, 3A, Low Ambient Start Relay
3PDT, 120A, Alarm and Safely Relay
DPDT, 15A, Low Pressure Control Relay
3PDT, 120A, Water Pump Starter Relay
060C
R5,R6
R9,R10
R11,R12
R19,R20
R21
Unit Size
Pieces/Unit
050C
Description
Part
Number
040C
Schem.
Symbol
028814400
032508101
028814400
019643000
028814400
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Time Delays
TD1,2
TD5,6
TD9,10
1 Second Part Winding Time Delay
300 Second Compressor Lockout Time Delay
165 Second Low Ambient Start Time Delay
028210101
028381900
032358500
2
2
2
2
2
2
2
2
2
FS1,2
OP1,2
HP1,2
LP1,2
TC1
PS1,2
S3
CCL1,
CL1,2 &
SC1,2
F1
F2 & F3
Controls
Freeze Protection Control
Oil Pressure Control
High Pressure Control
Low Pressure Control
Control Sequencer, R23AAG
4-Stage Capacity Control Thermostat
SPST, 6 Amp, Compressor Pumpdown Switch
SPST, 20 Amp, Control System Switch
Indicator Lights
White Neon
Indicator Lights
Red
001354800
001354900
001354400
001354500
034922000K
027664200
001355000
024735200
016508304
016508303
2
2
2
2
2
2
2
2
2
2
2
2
1
2
1
5
5
1
2
1
5
5
1
2
1
5
5
Fuse, 6 Amp, Control Circuit
Fuseholder, 15 Amp
Fuseholder, 30 Amp (Code 11=B or C)
Fuse, 4 Amp, 208V (Code 04=12)
Fuse, 3 Amp, 460V (Code 04=29 or 27)
020568500
018690600
047354101
046742214
046742209
1
1
2
2
2
1
1
2
2
2
1
1
2
2
2
PB1
FTB
CTB
NTB
Power Block
3 Pole, 600A, Terminal Power Block
Terminal Blocks
14 Terminals, 20A, 300V, Field Control Terminal Block
28 Terminals, 20A, 300V, Control Terminal Block
7 Terminals, Neutral Bar Terminal Block
030372726
1
1
1
022431214
015998128
037530800
1
2
2
1
2
2
1
2
2
T1
T1
T2
Control Circuit Transformer
230/460-115V, .75 KVA Transformer (Code 04=27 or 29)
208/277/380-115V, .75 KVA Transformer (Code 04=28)
Optional Alarm Bell
24 Volt Alarm Bell 038253905
038253914
1
1
1
1
1
1
017809400
017503800
1
1
1
1
1
1
120-24Volt,.04 KVA, Transformer
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 11
Power & Control Panel
WHR-070, 080, 090, 110, 120 - Schematic
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 12
Power & Control Panel
WHR-070, 080, 090, 110, 120 / Power Panel - Components List
Part
Number
Description
CB1,2,
3,4
CB1,2,
3,4
CB1,2,
3,4
CB1,2,
3,4
Circuit Breakers - 208/230V/60Hz/3Ph Unit Voltage
100 Amp, 240 Volt, 3 Pole - Units with Unit Mounted Std. Condensers
(G.O. Code 08=A) 25 Hp Compressor Circuit.
125 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. Standard Condensers.
(G.O. Code 08=A) See Note 1. 35 Hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units w/o Unit Mtd. Condensers
(G.O. Code 08=Y) See Note 2. 35 Hp Compressor Circuit.
150 Amp, 240 Volt, 3 Pole - Units with Unit Mtd. High Pressure Cond.
(G.O. Code 08=B) See Note 2. 35 Hp Compressor Circuit.
CB1,2,
3,4
M1 thru
M8
Unit Size
Pieces/Unit
070C
080C
090C
100C
110C
120C
Schem.
Symbol
022427413
2 1 2 1
043758901
1 2 3 2 3 4
043758902
1 2 3 2 3 4
043758902
2 2 3 2 3 4
Circuit Breakers - 460V/60Hz/3Ph or 380V/50Hz/3Ph Unit Voltage
50 Amp, 480 Volt, 3 Pole - 25 Hp Compressor Circuit.
70 Amp, 480 Volt, 3 Pole - 35 Hp Compressor Circuit.
022427407
022427408
2 1 2 1
1 2 3 2 3 4
Contactors - 208/230V/60Hz/3Ph
60 Amp, 600 Volt, 3 Pole, 25 Hp Compressor Circuit
75 Amp, 600 Volt, 3 Pole, 35 Hp Compressor Circuit
027514105 2 4 2
027514106 2 4 6 4 6 8
M1 thru
M8
Contactors - 460V/60Hz/3Ph Across-The-Line Start
50 Amp, 600 Volt, 3 Pole, 25 Hp Compressor Circuit
75 Amp, 600 Volt, 3 Pole, 35 Hp Compressor Circuit
027514104
027514106
M1 thru
M8
Contactors - 460/60Hz/3Ph Part Winding Start
25 Amp, 600 Volt, 3 Pole, 25 Hp Compressor Circuit
40 Amp, 600 Volt, 3 Pole, 35 Hp Compressor Circuit
027514101 2 4 2
027514103 2 4 6 4 6 8
2 1 2 1
1 2 3 2 3 4
Notes:
1. Replaces obsolete part number 001414300 (Heinemann No. CJ3G3U1251). When replacing old style circuit breaker with new style,
mounting bracket 0443420B-00 must be ordered (one per circuit breaker).
2. Replaces obsolete part number 018271701 (Heinemann No. CJ3G3U1501). When replacing old style circuit breaker with new style,
mounting bracket 044342000 must be ordered (one per circuit breaker).
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 13
Power & Control Panel
WHR-070, 080, 090, 110, 120 / Control Panel - Components List
Schem.
Symbol
Description
R3,4
R5-8
R9,10
R11-14
R19,20
R21
Relays
SPDT, 3A, Compressor 3,4 Starting Relay
3PDT, 120A, Compressor Lockout Relay
SPDT, 3A, Low Ambient Start Relay
3PDT, 120A, Alarm and Safely Relay
DPDT, 15A, Low Pressure Control Relay
3PDT, 120A, Water Pump Starter Relay
032508101
028814400
032508101
028814400
019643000
028814400
1
3
2
3
2
1
1
3
2
3
2
1
1
3
2
3
2
1
2
4
2
4
2
1
2
4
2
4
2
1
2
4
2
4
2
1
TD1-4
TD5-8
TD9,10
TD11
TD12,13,
Time Delays
1 Second Part Winding Time Delay
300 Second Compressor Lockout Time Delay, MOR120A1X300
165 Second Low Ambient Start Time Delay
20 Second Compressor Sequencing Time Delay
40 Second Compressor Sequencing Time Delay
028210101
028381900
032358500
028210106
028210107
3
3
2
1
1
3
3
2
1
1
3
3
2
1
1
4
4
2
1
2
4
4
2
1
2
4
4
2
1
2
070C
080C
090C
100C
110C
120C
Part
Number
Unit Size
Pieces/Unit
Controls
FS1,2 Freeze Protection Control
001354800 2 2 2 2 2 2
OP1-4
Oil Pressure Control
001354900 3 3 3 4 4 4
HP1,2 High Pressure Control
001354400 2 2 2 2 2 2
LP1,2 Low Pressure Control
001354500 2 2 2 2 2 2
Control Sequencer, R23AAG 034922000K
TC1
4-Stage Capacity Control Thermostat
027664200 1 1 1 1 1 1
PS1,2 SPST, 6 Amp, Compressor Pumpdown Switch
001355000 2 2 2 2 2 2
S3
SPST, 20 Amp, Control System Switch
024735200 1 1 1 1 1 1
S5
DPDT, 15 Amp, Lead-Lag Switch
019187300 1 1 1 1 1 1
S4
4DPT, 10 Amp, Lead-Lag Switch
001355100 1 1 1 1 1 1
CCL1, Indicator Lights
White Neon
016508304 7 7 7 9 9 9
CL1-4
SC1-4
F1
Fuse, 6 Amp, Control Circuit
020568500 1 1 1 1 1 1
Fuseholder, 15 Amp
018690600 1 1 1 1 1 1
F2 Fuseholder, 30 Amp (Code 11=B or C)
047354101 2 2 2 2 2 2
&
Fuse, 6 Amp, 208V (Code 04=12)
046742216 2 2 2 2 2 2
F3
Fuse, 5 Amp, 230V (Code 04=29)
046742215 2 2 2 2 2 2
Fuse, 4 Amp, 460V (Code 04=27)
046742214 2 2 2 2 2 2
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 14
Power & Control Panel
WHR-070, 080, 090, 110, 120 / Control Panel - Components List, Cont’d.
PB1
Power Block
3 Pole, 840A, 600V, Terminal Power Block
030372724
1 1 1 1 1 1
FTB
CTB
CTB
NTB
Terminal Blocks
14 Terminals, 20A, 300V, Field Control Terminal Block
30 Terminals, 20A, 300V, Control Terminal Block
6 Terminals, 20A, 300V, Control Terminal Block
16 Terminals, Neutral Bar Terminal Block
022431214
015998130
015998106
037530700
1
2
1
1
T1
Control Circuit Transformer
230/460-115V, .75 KVA Transformer (Code 04=27 or 29)
208/277/380-115V, .75 KVA Transformer (Code 04=28)
038253905
038253914
1 1 1 1 1 1
1 1 1 1 1 1
T2
Optional Alarm Bell (Code 11=A)
24 Volt Alarm Bell 120-24 Volt, .04 KVA, Transformer
017809400
017503800
1 1 1 1 1 1
1 1 1 1 1 1
Rev. H 12/2013
070C
080C
090C
100C
110C
120C
Description
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Part
Number
Unit Size
Pieces/Unit
Schem.
Symbol
1
2
1
1
1
2
1
1
1
2
1
1
1
2
1
1
1
2
1
1
RPL 055224300 / Page 15
Compressors
008C-060C / Components List
Note: All compressors include solid-state motor protector
Model No.
HP
Notes
V
S
U
Part No.
Q
WHR-008C
WHR-008C
7.5 1 A N 1
7.5 4 A N 1
019648100
019648200
WHR-010C
WHR-010C
WHR-015C
WHR-015C
101A11
104A11
023576100
023576200
202A11
204P11
027398400
031784900
WHR-020C 252A11
WHR-020C 254P11
023576700
031785100
WHR-025C
WHR-025C
30 2 A 1&2 1
30 4 P 1&2 1
027398600
031785200
WHR-030C
WHR-030C
35 2 A 1&2 1
35 4 P 1&2 1
023577000
031309900
WHR-040C
WHR-040C
WHR-040C
WHR-040C
25 2 A N 2
25 4 P N 2
252A12
254P12
023576600
031785000
023576700
031785100
WHR-050C
WHR-050C
WHR-050C
WHR-050C
WHR-050C
WHR-050C
WHR-050C
WHR-050C
25 2 A N 1
35 2 A N 1
25 4 P N 1
35 4 P N 1
252A11
352A11
254P11
354P11
023576600
023576900
031785000
031785300
023576700
023577000
031785100
031309900
WHR-060C
WHR-060C
WHR-060C
WHR-060C
35
35
35
35
023576900
031785300
023577000
031309900
2
2
2
4
A
A
A
P
N
N
1&2
1&2
2
2
2
2
Notes:
V = Voltage: 1 = 208-240 volts.
2 = 208-240/460 volts, part winding start on 208-240 volts only.
4 = 460 volts part winding only.
S = Starting: A = Across-the-line.
P = Part winding.
U = Unloading: N = 208-240 volts.
1 = 1 bank unloading on each compressor.
2 = Additional bank of unloading available with kits.
Q = Quantity required per unit.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 16
Compressors
070C-120C / Components List
Note: All compressors include solid-state motor protector
Model No.
HP
Notes
V
S
U
Part No.
Q
WHR-070C
WHR-070C
WHR-070C
WHR-070C
WHR-070C
WHR-070C
WHR-080C
WHR-080C
WHR-080C
WHR-080C
WHR-080C
WHR-080C
35
50T
35
50T
35
35
2
2
4
4
2
4
A N
A N
P N
P N
A 1
P1&2
1
1
1
1
1
1
023576900
023577200
031785300
031785400
023577000
031309900
35
60T
35
35
35
60T
2
2
4
2
4
4
A
A
P
A
P
P
N
N
N
1
1
N
1
1
1
1
1
1
023576900
023577400
031785300
023577000
031309900
031785500
WHR-090C
WHR-090C
WHR-090C
WHR-090C
WHR-090C
WHR-090C
35
70T
35
70T
35
35
2
2
4
4
2
4
A
A
P
P
A
P
N
N
N
N
1
1
1
1
1
1
1
1
023576900
023577700
031785300
031785600
023577000
031309900
WHR-100C
WHR-100C
WHR-110C
WHR-110C
WHR-110C
WHR-110C
60T 2 A N
60T 4 P N
2
2
023577400
031785500
60
70T
60T
70T
N
N
N
N
1
1
1
1
023577400
023577700
031785500
031785600
WHR-120C
WHR-120C
70T 2 A N
70T 4 P N
2
2
023577700
031785600
2
2
4
4
A
A
P
P
Notes:
V = Voltage: 1 = 208-240 volts.
2 = 208-240/460 volts, part winding start on 208-240 volts only.
4 = 460 volts part winding only.
S = Starting: A = Across-the-line.
P = Part winding.
U = Unloading: N = No unloading.
1 = 1 bank unloading on each compressor.
2 = Additional bank of unloading available with kits.
Q = Quantity required per unit.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 17
Compressors
Misc. Compressor & Mounting Vibration Isolation / Components List
Miscellaneous Compressor Components - All Unit Sizes
Part Description
Unloader Kit, Includes 115V Coil
Motor Protector (See note below)
Post 1981 Units: Copeland 071-0424-01
or Texas Instruments 15AA1600B
Pre 1980 Units: Copeland 071-0398-01 or Robertshaw MP23-1023
Pre 1980 Units: Copeland 071-0376-02
Crankcase Heater - 120 Volt
Compressor
HP
Part Number
20, 25, 30 & 35 HP
025633500
All Hp
044691500
25,35,40 HP-All Voltage
or 20,30 HP, 460V, PW
20,30 HP, Except 460V, PW
20,25,30,35 HP
030734400
027398700
020568100
Note: When ordering motor protectors for compressors in units built between January, 1980 and December, 1981, or if you are unsure of
unit manufacture date, please refer to vendor and model number of motor protector taken from nameplate on protector device.
Compressor Mounting Vibration Isolation - All Unit Sizes
WHR
Unit Size
008C thru 060C
008C thru 060C
070C thru 120C
Part Description
Part Number
Mounting Pad with Steel Plate
Rubber Spacer
Rubber-in-shear Rail Mount
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
066098601
019941000
017888103
RPL 055224300 / Page 18
Unit Mounting Vibration
Isolator Selection & Mounting Locations
Arrangements 1 & 2
Rear
4
3
1
2
Front
WHR
Model
Num.
Operating
Weight
(Lbs.)
Single Rubber-In-Shear Mountings
Mounting Locations
1
2
3
4
Spring-Flex Mountings
Mounting Locations
1
2
3
4
Type RP-Mounting Selection No.
Type CP-Mounting Selection No.
ARRANGEMENT 1 - With Water Cooled Condensers
008C
010C
015C
020C
025C
030C
040C
050C
060C
070C
080C
090C
100C
110C
120C
925
994
1231
1419
1647
1716
2456
2952
3163
4378
4479
4981
5758
6139
6400
2-Green 2-Green
2-Green 2-Green
2-Green 2-Green
3-Red 3-Green
3-Red 3-Green
3-Green 3-Green
3-Green 3-Green
3-Gray 3-Gray
3-Gray 3-Gray
4-Black 4-Black
4-Black 4-Black
4-Black 4-Black
4-Black 4-Black
4-Red
4-Red
4-Red
4-Red
ARRANGEMENT 2
2-Green 2-Green1-241-241-241-24
2-Green 2-Green1-241-241-241-24
2-Green 2-Green1-251-251-251-25
3-Red 3-Red 1-251-271-251-25
3-Red 3-Red 1-261-271-261-25
3-Red 3-Red 1-261-271-261-25
3-Green 3-Green1-271-271-271-27
3-Gray 3-Gray1-311-311-311-31
3-Gray 3-Gray1-311-311-311-31
4-Black 4-Black2-262-262-272-27
4-Black 4-Black2-272-272-272-27
4-Red 4-Red 2-272-272-282-28
4-Red 4-Red 2-272-272-282-28
4-Red 4-Red 2-282-292-312-31
4-Red 4-Red 2-282-282-312-31
- With Mounted Receivers
008C
010C
015C
020C
025C
030C
040C
050C
060C
070C
080C
090C
100C
110C
120C
845
949
1066
1300
1487
1556
2296
2672
2833
3913
3989
4381
5138
5409
5560
2-Green
2-Green
2-Green
3-Red
3-Red
3-Red
3-Green
3-Gray
3-Gray
4-Gray
4-Gray
4-Black
4-Black
4-Black
4-Black
2-Green
2-Green
2-Green
3-Red
3-Red
3-Red
3-Green
3-Gray
3-Gray
4-Black
4-Black
4-Black
4-Red
4-Red
4-Red
2-Green
2-Green
2-Green
3-Green
3-Green
3-Green
3-Green
3-Gray
3-Gray
4-Gray
4-Gray
4-Black
4-Black
4-Black
4-Black
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
2-Green1-241-241-241-24
2-Green1-241-241-241-24
2-Green1-241-241-241-24
3-Red 1-251-261-251-24
3-Red 1-251-271-251-24
3-Red 1-261-271-251-24
3-Green1-271-271-271-27
3-Gray1-281-281-281-28
3-Gray1-281-281-281-28
4-Black1-311-312-272-27
4-Black2-262-262-272-27
4-Black2-262-262-272-27
4-Red 2-272-272-282-28
4-Red 2-272-272-282-28
4-Red 2-282-282-312-31
Rev. H 12/2013
RPL 055224300 / Page 19
Unit Mounting Vibration
Isolator Selection & Mounting Locations
Arrangements 3 & 4
4
Rear
3
1
2
Front
WHR
Model
Num.
Operating
Weight
(Lbs.)
Single Rubber-In-Shear Mountings
Mounting Locations
1
2
3
4
Spring-Flex Mountings
Mounting Locations
1
2
3
4
Type RP-Mounting Selection No.
Type CP-Mounting Selection No.
ARRANGEMENT 3 - Less Condensers
008C
010C
015C
020C
025C
030C
040C
050C
060C
070C
080C
090C
100C
110C
120C
780
849
946
1119
1307
1376
1855
2212
2353
3383
3439
3731
4478
4649
4700
2-Green 2-Green 2-Red 2-Red 1-241-241-231-23
2-Green 2-Green 2-Red 2-Red 1-241-241-231-23
2-Green 2-Green 2-Red 2-Red 1-251-251-241-24
3-Black 3-Red 3-Red 3-Black1-241-251-251-24
3-Red
3-Red 3-Red 3-Red 1-251-261-261-25
3-Red
3-Red 3-Red 3-Red 1-251-261-261-25
3-Green 3-Green 3-Green 3-Green1-261-261-261-26
3-Green 3-Green 3-Green 3-Green1-271-271-271-27
3-Green 3-Green 3-Green 3-Green1-271-271-271-27
3-Gray 3-Gray 4-Black 4-Black1-281-281-311-31
3-Gray 3-Gray 4-Black 4-Black1-311-312-262-26
3-Gray 3-Gray 4-Black 4-Black1-311-312-272-27
4-Black 4-Black 4-Black 4-Black2-262-262-272-27
4-Black 4-Black 4-Black 4-Black2-272-272-282-28
4-Black 4-Black 4-Black 4-Black2-272-272-282-28
ARRANGEMENT 4 - With Dual Heat Recovery Condensers
040C
050C
060C
070C
080C
090C
100C
110C
120C
3260
3710
3940
5380
5500
6200
7000
7570
8020
3-Gray
3-Gray
4-Black
4-Black
4-Black
4-Black
4-Red
4-Red
4-Red
3-Gray
3-Gray
4-Black
4-Black
4-Black
4-Black
4-Red
4-Red
4-Red
3-Gray
3-Gray
4-Black
4-Red
4-Red
4-Red
4-Red
4-Green
4-Green
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
3-Gray1-311-311-311-31
3-Gray2-262-262-262-26
4-Black2-272-272-272-27
4-Red 2-282-282-312-31
4-Red 2-282-282-312-31
4-Red 2-282-282-312-31
4-Red 2-312-314-274-27
4-Green2-312-314-274-27
4-Green4-274-274-274-27
Rev. H 12/2013
RPL 055224300 / Page 20
Unit Mounting Vibration
Single Rubber-in-Shear/Isolator
‘D’ Dia.
2-Holes
‘W’
‘C’
‘L’
‘B’ Dia.
Positioning Pin
‘A’
‘H’
‘E’
Type RP
Mounting
Selection No.
Part No.
RP-2-Green
RP-3-Green
RP-3-Gray
RP-3-Red
RP-4-Black
RP-4-Red
021639503
021639703
021639705
021639701
021639704
021639701
Type
Color
Max. Load
Each (Lbs.)
RP-2 Red
240
RP-2
Green380
RP-3 Black
250
RP-3 Red
525
RR-3 Green
750
RP-3 Gray
1100
RP-4 Black
1500
RP-4 Red
2250
RP-4 Green
3000
Defl.
(In.)
A
B
C
Dimensions (Inches)
D
E
H
L
W
.25
1-3/4 3/8
3 11/16 7/32 1-1/4 3-7/8 2-3/8
.251-3/4
3/83
11/16
7/32
1-1/4
3-7/8
2-3/8
.25
2-1/2 1/2 4-1/8 9/16
1/4
1-3/4 5-1/2 3-3/8
.25
2-1/2 1/2 4-1/8 9/16
1/4
1-3/4 5-1/2 3-3/8
.25
2-1/2
1/2 4-1/8 9/16
1/4
1-3/4 5-1/2 3-3/8
.25
2-1/2 1/2 4-1/8 9/16
1/4
1-3/4 5-1/2 3-3/8
.25
3-3/4 5/8
5
9/16
1/4
1-3/4 6-1/2 4-1/4
.25
3-3/4 5/8
5
9/16
1/4
1-3/4 6-1/2 4-1/4
.25
3-3/4 5/8
5
9/16
1/4
1-3/4 6-1/2 4-1/4
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 21
Unit Mounting Vibration
Spring-Flex Mountings/Isolator
C/2
5/8”
1-3/8”
‘D’
‘C’
‘B’
‘A’
1/2” Dia. Positioning Pin
Adjust mounting so upper housing clears
lower housing by at least 1/16” and not
more than 1/2”.
‘E’
5/8”
Type CP
Mounting
Selection No.
Acoustical Non-skid
Neoprene Pad
Part No.
CP-1-23
CP-1-24
CP-1-25
CP-1-26
CP-1-27
CP-1-28
CP-1-31
CP-2-26
CP-2-27
CP-2-28
CP-2-31
CP-4-27
Type
CP-1-23
CP-1-24
CP-1-25
CP-1-26
CP-1-27
CP-1-28
CP-1-31
CP-2-26
CP-2-27
CP-2-28
CP-2-31
CP-4-27
Color
Gray with 1 Yellow Stripe
Gray with 2 Green Stripes
Gray with 1 Red Stripe
Gray with 2 White Stripes
Gray with 1 Orange Stripe
Gray with 1 Green Stripe
Gray with 2 Yellow Stripes
Gray with 2 White Stripes
Gray with 1 Orange Stripe
Gray with 1 Green Stripe
Gray with 2 Yellow Stripes
Gray with 1 Orange Stripe
Max. Load
Each (Lbs.)
225
325
450
600
750
900
1100
1200
1500
1800
2200
3000
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
021640323
021640324
021640325
021640326
021640327
021640328
021640331
021640426
021640427
021640428
021640431
024088727
Dimensions (Inches)
Defl.
(In.)
A
B
C
1.26
1.23
1.22
1.17
1.06
1.02
0.83
1.17
1.06
1.02
0.83
1.06
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
7-1/2
10-1/4
10-1/4
10-1/4
10-1/4
10-1/4
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
6-1/2
9-1/4
9-1/4
9-1/2
9-1/2
9-1/2
5
5
5
5
5
5
5
8
8
8
8
7-1/2
Rev. H 12/2013
D
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
2-3/4
5
E
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
5-7/8
6-1/8
RPL 055224300 / Page 22
Cooler Assembly
Arrangements 1, 2, 3 & 4 / Components List
To ensure accuracy of part numbers listed, contact Daikin Applied with information
from the Cooler Serial Plate (see page 24).
WHR
Unit Size
Part Description
Diameter (In.) Shell Length (In.)
Part No.
(Same as Model No. on Serial Plate)
(without Insulation)
Part No.
(Insulated)
Arrangements 1, 2, 3
008C, 010C-1,2,3
6.62
58.18
015C-1,2,3
8.62
58.18
020C-1,2,3
6.62
82.18
025C-1,2,3
8.62
70.18
030C-1,2,3
8.62
82.18
040C-1,2,3
8.62 106.18
050C-1,2,3
10.75 94.18
060C-1,2,3
10.75 106.18
070C, 080C-1,2,3
12.75
93.18
090C-1,2,3
12.75 117.18
100C-1,2,3
14.00 105.20
110C-120C-1,2,3
14.00
117.20
Arrangement 4 Units with dual condenser circuits
022796900
022799000
027303600
027303500
027303400
026663300
026661600
026661700
026663400
026669200
026669300
026669400
025221801
025221802
027888001
027888002
027888003
027299801
027299802
027299803
027284601
027284602
027284603
027284604
040C-4
050C-4
060C-4
070C, 080C-4
090C-4
100C-4
110C-120C-4
040541800
039577500
039577500
040546900
040184400
040545700
040544000
039577401
039577402
039577403
040184301
040184302
040184303
040184304
8.62
10.75
10.75
12.75
12.75
14.00
14.00
106.18
95.18
106.18
93.18
117.18
105.20
117.20
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 23
Cooler Assembly
Sub-Assembly Diagram
To ensure accuracy of part numbers listed, contact Daikin Applied with information
from the Cooler Serial Plate.
251
256
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 24
Cooler Assembly
Sub-Assembly / Components List
To ensure accuracy of part numbers listed, contact Daikin Applied with information
from the Cooler Serial Plate (see page 24).
110/120C
100C
090C
070C/080C
060C
050C
040C
030C
025C
Part
Number
020C
Description
015C
Bub.
Num.
008C/010C
WHR Unit Size-Pieces Per Unit
Cooler Tubes (Includes Internal Turbulators)
250
60” Tube Length 026662303
55 92
250
72” Tube Length 026662304 92
250 84” Tube Length0266623055592
250 96” Tube Length
026662306
142
201
250 108” Tube Length
026662307
86
142
244
250 120” Tube Length
026662308
201
244
251*
Front Head Ring 022793500 1
251*
Front Head Ring 022797300 1
251*
Front Head Ring 027302500 1
251*
Front Head Ring 027302200 1 1
251*Front Head Ring
0266627001
251*Front Head Ring
0239844001
1
251*Front Head RIng
0266488001
1
251*Front Head Ring
0266572001
1
252
Rear Head Ring 022793400
1
252
Rear Head Ring 022796800 1
252
Rear Head Ring 027302600 1
252
Rear Head Ring 027302100 1 1
252 Rear Head Ring
0266628001
252 Rear Head Ring
0239845001
1
252 Rear Head Ring
0266589001
1
252 Rear Head Ring
0266573001
1
253*
Front Cover Plate (Incl. connections) 022795201
1
253*
Front Cover Plate (Incl. connections) 022798201 1
253*
Front Cover Plate (Incl. connections) 027874700 1
253*
Front Cover Plate (Incl. connections) 027874600 1 1
253*
Front Cover Plate (Incl. connections) 026662900 1
253*
Front Cover Plate (Incl. connections) 026661300 1 1
253*Front Cover Plate (Incl. connections)
0266636001
1
253* Fr.Cover Plate (Incl Conn.)(Suct.Line 2-5/8”)
0299038001
253*Front Cover Plate (Incl. connections)
0266702001
253*
Front Cover Plate (Arrg. C-4) 040542000 1
253*Front Cover Plate (Arrg. C-4)
0420831001
* No longer available
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 25
Cooler Assembly
Sub-Assembly / Components List, Cont’d.
To ensure accuracy of part numbers listed, contact Daikin Applied with information
from the Cooler Serial Plate (see page 24).
110/120C
100C
090C
070C/080C
060C
050C
040C
030C
025C
Part
Number
020C
Description
015C
Bub.
Num.
008C/010C
WHR Unit Size-Pieces Per Unit
Cooler Tubes (Includes Internal Turbulators)
254
Rear Cover Plate 022795400
1 1
254
Rear Cover Plate 022796800 1
254
Rear Cover Plate 022798400 1 1 1
254 Rear Cover Plate
0272930001
1
254 Rear Cover Plate
0266602001
1
254 Rear Cover Plate
0266576001
1
255
Gaskets (Front & Rear Heads) ** 022793600
4
255
Gaskets (Front & Rear Heads) ** 022797600 4
255
Gaskets (Front & Rear Heads) ** 027303800 4
255
Gaskets (Front & Rear Heads) ** 027303700 4 4
255
Gaskets (Front & Rear Heads) ** 026663100 4
255
Gaskets (Front & Rear Heads) ** 022795500 4 4
255 Gaskets (Front & Rear Heads) ** 0266603004
4
255 Gaskets (Front & Rear Heads) **
0266574004
4
Head Bolts
256* 1/2-13 x 2.75 022780000 24242424242424
256*5/8-11 x 3.75 022779900
32
32
40
40
40
* No longer available
** Good for ‘B’ vintage units also.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 26
Condenser Section
Location-Arrangement 1 / Components List
With Water Cooled Condensers
A
B
Condenser
WHR-008C-1, 010C-1, 015C-1
WHR-020C-1, 025C-1, 030C-1
E
C
CKT. 1
D
CKT. 2
F
CKT. 2
CKT. 1
WHR-070C-1, 080C-1,
090C-1, 100C-1, 110C-1, 120C-1
WHR-040C-1, 050C-1, 060C-1
WHR
Unit Size
Part Description
Condenser
Location Dia. (In.) Shell Length (In.)
F.P.T. (In.)
Part No.
(Insulated)
008C-1, 010C-1
015C-1
020C-1
025C-1, 030C-1
040C-1
050C-1
050C-1
060C-1
070C-1
070C-1
080C-1
080C-1
A
A
B
B
C & D
C
D
C
F
E
F
E
6
8
8
8
8
8
8
8
8
10
8
10
60
96
96
96
96
96
96
96
96
96
96
96
1.50” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
3.00” F.P.T
2.00” F.P.T
3.00” F.P.T
038910600
038910700
038910800
038010900
039656100
039656100
039656300
039656500
038911000
038911100
038911000
038911200
090C-1
090C-1
100C-1
110C-1
110C-1
120C-1
F
E
E &F
E
F
E &F
8
10
10
10
10
10
96
96
96
96
96
96
2.00” F.P.T
4.00” F.P.T
3.00” F.P.T
3.00” F.P.T
4.00” F.P.T
4.00” F.P.T
038911000
038911300
038911200
038911200
038911300
038911300
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 27
Condenser Section
Location-Arrangement 4 / Components List
With Dual Water Cooled Condensers Per Refrigerant Circuit
WHR-070C-4, 080C-4, 090C-4,
100C-4, 110C-4, 120C-4
WHR-040C-4, 050C-4, 060C-4
WHR
Unit Size
040C-4
040C-4
040C-4
050C-4
050C-4
050C-4
050C-4
060C-4
060C-4
060C-4
070C-4
070C-4
070C-4
070C-4
080C-4
080C-4
080C-4
080C-4
090C-4
090C-4
090C-4
090C-4
100C-4
100C-4
110C-4
110C-4
110C-4
110C-4
120C-4
120C-4
Part Description
Condenser
Location Dia. (In.) Shell Length (In.)
F.P.T. (In.)
G&I
H
J
G
I
H
J
G&I
H
J
K
L
M
N
K
L
M
N
K
L
M
N
K&M
L&N
M
N
K
L
K&M
L&N
8
8
8
8
8
8
8
8
8
8
8
8
10
10
8
8
10
10
8
8
12
12
10
10
12
12
10
10
12
12
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T
2.00” F.P.T Water
2.00” F.P.T Water
2.00” F.P.T Water
2.00” F.P.T Water
2.00” F.P.T Water
3.00” F.P.T Water
3.00” F.P.T Water
2.00” F.P.T Water
2.00” F.P.T Water
3.00” F.P.T Water
3.00” F.P.T Water
2.00” F.P.T Water
2.00” F.P.T Water
4.00” F.P.T Water
4.00” F.P.T Water
3.00” F.P.T Water
3.00” F.P.T Water
4.00” F.P.T Water
4.00” F.P.T Water
3.00” F.P.T Water
3.00” F.P.T Water
4.00” F.P.T Water
4.00” F.P.T Water
Rev. H 12/2013
Part No.
(Insulated)
040540700
040541300
040541900
040540700
040540900
040541300
040541900
039577800
039578000
040539100
040183500
040860100
040547100
040547000
040183500
040860100
040544100
040860000
040183500
040183700
040183300
040184000
040544100
040544200
040183300
040184000
040544100
040544200
040183300
040184000
RPL 055224300 / Page 28
Condenser Section
Sub-Assembly Diagram
Condenser Sub-Assembly
Condenser Serial Plate
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 29
Condenser Section
Sub-Assembly / Components List
Part
Number
Qty. Per
Condenser
Condenser Model No. 038910600 - 6” Dia., 60” Shell Length
Condenser Tube, External Integral Finned, 60” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gaskets, Connection End and/or Return End
028638601
038908600
038908700
021026300
18
1
1
2
262
263
264
265
266
Condenser Model No. 038910700 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
036607200
038908800
020897900
020898500
24
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038910800 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tube) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
24
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038910900 -8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tube) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
34
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 039656100 -8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tube) (Tube same as condenser)
028638602
036607200
038908800
020897900
020897900
038910300
24
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 039656300 -8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tube) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
Bub.
No.
Description
262
263
264
265,266
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 30
Condenser Section
Sub-Assembly / Components List, Cont’d.
Bub.
No.
Description
Part
Number
Qty. Per
Condenser
262
263
264
265
266
267
Condenser Model No. 040541300 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
24
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040541900 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
24
1
1
1
1
1
262
263
264
265
266
Condenser Model No. 040540900 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
036607200
038908800
020897900
020898500
34
1
1
1
1
262
263
264
265
266
Condenser Model No. 039577800 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
036607200
038908800
020897900
020898500
34
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 039578000 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 31
Condenser Section
Sub-Assembly / Components List, Cont’d.
Bub.
No.
Description
Part
Number
Qty. Per
Condenser
262
263
264
265
266
267
Condenser Model No. 040539100 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638601
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040138500 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040860100 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
262
263
264
265
266
Condenser Model No. 040547100 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
038183800
038908900
021027100
021027200
56
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040547000 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038183800
038908900
021027100
021027200
038910400
58
1
1
1
1
1
262
263
264
265
266
Condenser Model No. 040544100 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
038183800
038908900
021027100
021027200
64
1
1
1
1
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 32
Condenser Section
Sub-Assembly / Components List, Cont’d.
Bub.
No.
Description
Part
Number
Qty. Per
Condenser
262
263
264
265
266
267
Condenser Model No. 039656500 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038911000 - 8” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
036607200
038908800
020897900
020897900
038910300
34
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038911100 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038183800
038908900
021027100
021027200
038910400
56
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038911200 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038183800
038908900
021027100
021027200
038910400
64
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 038911300 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038183800
038908900
021026100
021026100
038910400
64
1
1
1
1
1
Condenser Model No. 040540700 - 8” Dia., 96” Shell Length
262
Condenser Tube, External Integral Finned, 96” Length
263
Condenser Head, Connection End
264
Condenser Head, Return End
265
Head Gasket, Connection End 266
Head Gasket, Return End
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
028638602
24
036607200
1
038908800
1
020897900
1
020898500
1
RPL 055224300 / Page 33
Condenser Section
Sub-Assembly / Components List, Cont’d.
Bub.
No.
Description
Condenser Model No. 040860000 - 10” Dia., 96” Shell Length
262
Condenser Tube, External Integral Finned, 96” Length
263
Condenser Head, Connection End
264
Condenser Head, Return End
265
Head Gasket, Connection End 266
Head Gasket, Return End
267
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
Condenser Model No. 040183700 - 8” Dia., 96” Shell Length
262
Condenser Tube, External Integral Finned, 96” Length
263
Condenser Head, Connection End
264
Condenser Head, Return End
265
Head Gasket, Connection End 266
Head Gasket, Return End
267
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
Part
Number
Qty. Per
Condenser
028638602
038183800
038908900
021027100
021027200
038910400
64
1
1
1
1
1
028638602
036607200
038908800
020897900
020898500
038910300
34
1
1
1
1
1
262
263
264
265
266
Condenser Model No. 040183300 - 12” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
028638602
038909000
038183900
021026100
021026200
85
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040184000 - 12” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038909000
038183900
021026100
021026200
038910500
85
1
1
1
1
1
262
263
264
265
266
267
Condenser Model No. 040544200 - 10” Dia., 96” Shell Length
Condenser Tube, External Integral Finned, 96” Length
Condenser Head, Connection End
Condenser Head, Return End
Head Gasket, Connection End Head Gasket, Return End
Subcooler Assembly (Includes Tubes) (Tube same as condenser)
028638602
038183800
038908900
021027100
021027200
038910400
64
1
1
1
1
1
269
270
All Size Condensers - Common Parts
Stud Bolt, 5/8-11x4.00”
Hex Nut, 5/8-11
037521600
000288500
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 34
Piping & Miscellaneous
008C - 030C / Components List
Description
*Expansion Valve, Thermostatic Controlled
8 Ton, 5/8” In, 7/8” Out, 60” Long Cap Tube
20 Ton, 7/8” In, 1-1/8” Out, 60” Long Cap Tube
20 Ton, 7/8” In, 1-3/8” Out, 60” Long Cap Tube
30 Ton, 7/8” In, 1-3/8” Out, 60” Cap Tube
**Solenoid Valve, Liquid Line, 120 Volt, Pilot
11 Ton, 5/8” ODF x 3/4” ODM, In-Line
25 Ton, 7/8” ODF x 1-1/8” ODM, In-Line
008C-1
008C-2
008C-3
010C-1
010C-2
010C-3
015C-1
015C-2
015C-3
020C-1
020C-2
020C-3
025C-1
025C-2
025C-3
030C-1
030C-2
030C-3
WHR Unit Size-Pieces Per Unit
Part
Number
030389000 1 1 1 1 1 1
024029602 1 1 1
024029601 1 1 1 1 1 1
024029605 1 1 1
031007401 1 1 1 1 1 1
031007403 1 1 1
30.5 Ton, 7/8” ODF x 7/8” ODM, In-Line
025327500 1 1 1 1 1 1 1 1 1
1/4” Flare x 1/4” Flare x 1/4” Flare, Pilot
027517500 1 1 1 1 1 1 1 1 1
Pressure Relief Valve, 450 PSI
039441300 11 11 11 11 11 1 1
Purge Valve, Shutoff, 1/4” Connections
001360100 11 11 11 11 11 1 1
Liquid Line Shutoff Valve, Manual
5/8” ODM x 1/2” ODS Connections
001359900 1 1 1 1
7/8” ODM x 3/4” ODS Connections
001360000 1 1 1 1 1
1/4” Flare, 1-5/8” ODS x 1-5/8 ODS Connections 033036200 1 1 1
Liquid Indicator, Glass Eyepiece with Cap (Units with Hot Gas Bypass have one additional indicator)
4-7/8” Long, 5/8” ODS x 5/8” ODS Connection
001359200 1 1 1 1 1 1
6-1/4” Long, 7/8” ODS x 7/8” ODS Connection
001359300 1 1 1
Liquid Indicator, Saddle Type, Two Piece (Units with Hot Gas Bypass have one additional indicator)
Cap
0224277001
111
11
11
1
Body, 7/8” Connections
0253296001
111
11
11
1
Filter-Drier Core, Element Replacement
3-1/8” Dia. x 6” Long, 42 Cubic Inch
001361000 1 1 1
3-3/4” Dia. x 5-1/2” Long, 48 Cubic Inch
001360800 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Filter-Drier Shell
42 Cubic Inch, 5/8” ODF Connections
001360900 1 1 1
48 Cubic Inch, 5/8” ODF Connections
001360600 1 1 1
48 Cubic Inch, 7/8” ODF Connections
001360700 1 1 1 1 1 1 1 1 1 1 1 1
Optional Hot Gas Bypass Modulating Pressure Valve
7/8” ODF Conn., 60” Long Cap. Tube, 55-70 Lbs. 023072900 1 1 1 1 1 1 1 1 1
1-1/8” ODF Conn., 60” Long Cap Tube, 55-70 Lbs. 022973500 1 1 1 1 1 1 1 1 1
Optional Hot Gas Bypass Solenoid Valve, 120 Volt
25 Ton, 7/8” ODF x 1-1/8” ODM Connections
031007403 1 1 1 1 1 1 1 1 1
39 Ton, 1-1/8” ODF x 1-1/8” ODM Connections
031007405 1 1 1 1 1 1 1 1 1
Notes:
*Units built before August,1980 used 40 ton (Sporlan No. OVE-40-CP-100). Recommended replacement is 30 ton valve listed. New 30 ton
valve is directly interchangeable with old 40 ton valve.
** Units with engineering revision number 02 and greater have in-line solenoid valves. Engineering revision number 01 has pilot valves.
The change to in-line solenoid valves occured approximately October, 1982.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 35
Piping & Miscellaneous
008C - 030C / Components List, Cont’d.
Description
008C-1
008C-2
008C-3
010C-1
010C-2
010C-3
015C-1
015C-2
015C-3
020C-1
020C-2
020C-3
025C-1
025C-2
025C-3
030C-1
030C-2
030C-3
WHR Unit Size-Pieces Per Unit
Part
Number
Receiver, 10-3/4” Dia.x72”Lg, 1-5/8” ODS Conn. 027294200111
Optional Muffler, (Discharge Line)
7.5-10 Ton, 7/8” Connections
018899001 1 1
10-15 Ton, 1-1/8” Connections
001383900 1 1
15-25 Ton, 1-3/8” Connections
00137310011
Optional Gauges (Package for 20-30 / 715335AG01)
Suction Pressure, 30-150 Lbs., 1/8” Thread
017503500 11 111 111 111 1 1111 11
Oil Pressure, 30-150 Lbs. 1/8” Thread
017503500 11 111 111 111 1 1111 11
High Pressure, 800 Lbs., 1/8” Thread
040159300 11 111 111 111 1 1111 11
Valve, Gauge Shutoff, 1/4” Flare x 1/8”FPT
028383500 33 333 333 333 3 3333 33
Water Flow Switch
017503300 11 111 111 111 1 1111 11
Lock Cylinder and Key
001157200 11 111 111 111 1 1111 11
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 36
Piping & Miscellaneous
040C - 060C / Components List
Description
*Expansion Valve, Thermostatic Controlled
20 Ton, 7/8” In, 1-3/8” Out, 60” Long Cap Tube
30 Ton, 7/8” In, 1-3/8” Out, 60” Cap Tube
**Solenoid Valve, Liquid Line, 120 Volt, Pilot
30.5 Ton, 7/8” ODF x 7/8” ODF, In-Line
Pressure Relief Valve, 450 PSI
Purge Valve, Shutoff, 1/4” Connections
Liquid Line Shutoff Valve, Manual
7/8” ODM x 3/4” ODS Connections
1/4” ODM x 1-5/8” ODS Connections
1/4” Flare Gauge Connection, 7/8” ODS Connections
Liquid Indicator, Saddle Type, Two Piece
Cap
Body, 7/8” Connections
Filter-Drier Core, Element Replacement
Filter-Drier Shell, 7/8” ODF Connections
Optional Hot Gas Bypass Modulating Pressure Valve
1-1/8” ODF Conn., 60” Long Cap Tube, 55-70 Lbs.
Optional Hot Gas Bypass Solenoid Valve, 120 Volt
39 Ton, 1-1/8” ODF Connections
Receiver, 10-3/4” Dia. x 72”Long, 1-5/8” ODS Connection
Optional Muffler, (Discharge Line) (Code 13=1)
10-15 Ton, 1-1/8” Connections
15-25 Ton, 1-3/8” Connections
Optional Gauges (Code 07=A)
Suction Pressure, 30-150 Lbs., 1/8” Thread
Oil Pressure, 30-150 Lbs. 1/8” Thread
High Pressure, 800 Lbs., 1/8” Thread
Valve, Gauge Shutoff, 1/4” Flare x 1/8” FPT
Water Flow Switch
Lock Cylinder and Key
040C-1
040C-2
040C-3
040C-4
050C-1
050C-2
050C-3
050C-4
060C-1
060C-2
060C-3
060C-4
WHR Unit Size-Pieces Per Unit
Part
Number
024029601 2 2 2 2 1 1 1 1
024029605 1 1 1 1 2 2 2 2
025327500 2 2 2 2 2 2 2 2 2 2 2 2
039441300222222222
001360100224224224
001360000 1 1 1
033036200 1 1 1
032193502 1 1 1
02242770011 111 1 1111 11
02532960011 111 1 1111 11
00136080022 222 2 2222 22
00136070022 222 2 2222 22
022973500 1 1 1 1 1 1 1 1 1 1 1 1
03100740511 111 1 1111 11
027294200222
001383900 2 2 1 1
001373100 1 1 2 2
017503500 2 2 2 2 2 2 2 2 2 2 2 2
017503500 2 2 2 2 2 2 2 2 2 2 2 2
040159300 2 2 2 2 2 2 2 2 2 2 2 2
028383500 6 6 6 6 6 6 6 6 6 6 6 6
01750330011 111 1 1111 11
00115720011 111 1 1111 11
Notes:
*Units built before August,1980 used 40 ton (Sporlan No. OVE-40-CP-100). Recommended replacement is 30 ton valve listed. New 30 ton
valve is directly interchangeable with old 40 ton valve.
** Units with engineering revision number 02 and greater have in-line solenoid valves. Engineering revision number 01 has pilot valves.
The change to in-line solenoid valves occured approximately October, 1982.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 37
Piping & Miscellaneous
070C - 090C / Components List
Description
070C-1
070C-2
070C-3
070C-4
080C-1
080C-2
080C-3
080C-4
090C-1
090C-2
090C-3
090C-4
WHR Unit Size-Pieces Per Unit
Part
Number
*Expansion Valve, Thermostatic Controlled
30 Ton, 7/8” In, 1-3/8” Out, 60” Long Cap Tube
024029605 1 1 1 1 1 1 1 1 1 1 1 1
40 Ton, 7/8” In, 1-3/8” Out, 60” Long Cap Tube
024029501 1 1 1 1
70 Ton, 1-1/8” In, 1-3/8” Out, 60” Long Cap Tube
024029502 1 1 1 1 1 1 1 1
**Solenoid Valve, Liquid Line, 120 Volt, In-Line
30.5 Ton, 7/8” ODF x 7/8” ODF, Connections
025327500 1 1 1 1 1 1 1 1 1 1 1 1
58 Ton, 1-1/8” ODF x 1-1/8” ODF, Connections
025327600 1 1 1 1 1 1 1 1 1 1 1 1
Solenoid Valve, Liquid Line, 120 Volt, Pilot
1/4” Flare x 1/4” Flare x 1/4” Flare (Three-way)
027517500 2 2 2 2 2 2 2 2 2 2 2 2
Pressure Relief Valve, 450 PSI
039441300224224224
Purge Valve, Shutoff, 1/4” Connections
001360100224224224
Liquid Line Shutoff Valve, Manual
1-1/8” ODS Connections with 1/4” Gauge Port
019282100 1 1 1 1 1 1
7/8” ODM x 3/4” ODS Connection
001360000 1 1 1
1-5/8” ODS Connections with 1/4” Gauge Port
033036200 2 2 2
7/8” ODS Connections with 1/4” Gauge Port
032193502 1 1 1
Liquid Indicator, Saddle Type, Two Piece
Cap
02242770022 222 2 2222 22
Body, 7/8” Connections
02532960022 222 2 2222 22
Filter-Drier Core, Element Replacement
3-3/4” Diameter x 5-1/2” Long, 48 Cubic Inch00136080033 333 3 3333 33
Filter-Drier Shell
1-1/8” ODF Connections, 96 Cubic Inch
019190500 1 1 1 1 1 1 1 1 1 1 1 1
7/8” ODF Connections, 48 Cubic Inch
001360700 1 1 1 1 1 1 1 1 1 1 1 1
Optional Hot Gas Bypass Modulating Pressure Valve (Code 12=1)
1-1/8” ODF Connections, 60” Long Cap Tube
022973500 1 1 1 1 1 1 1 1 1 1 1 1
Optional Hot Gas Bypass Solenoid Valve, 120 Volt (Code12=1)
39 Ton, 1-1/8” ODF Connections, 120V
031007405 1 1 1 1 1 1 1 1 1 1 1 1
Optional Receivers, (Code 03=2)
1-5/8” ODS Connections, 8-5/8” Diameter x 96” Long
026667600111
2-1/8” ODS Connections, 10-3/4” Diameter x 96” Long
02666950011
2-1/8” ODS Connections, 12-3/4” Diameter x 96” Long
0266696001
Optional Discharge Line Muffler (Code 13=1)
1-5/8” ODS Connections
025687400111111
1-3/8” Connections, 15-25 Ton
001373100111111
Optional Gauges (Code 07=A)
1/8” NPT, 30-150 Lbs., Suction Pressure Gauge
017503500 2 2 2 2 2 2 2 2 2 2 2 2
1/8” NPT, 30-150 Lbs., Oil Presure Gauge
017503500 3 3 3 3 3 3 3 3 3 3 3 3
1/8” NPT, 800 Lbs., High Pressure Gauge
040159300 2 2 2 2 2 2 2 2 2 2 2 2
Valve, Gauge Shutoff
02838350077 777 7 7777 77
Water Flow Switch
01750330011 111 1 1111 11
Lock Cylinder and Key
00115720011 111 1 1111 11
Notes: *Units built before August,1980 used 40 ton (Sporlan No. OVE-40-CP-100). Recommended replacement is 30 ton valve listed. New 30 ton valve is directly interchangeable with old 40 ton valve.
** Units with engineering revision number 02 and greater have in-line solenoid valves. Engineering revision number 01 has pilot valves. The change to in-line solenoid valves occured approximately October, 1982.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 38
Piping & Miscellaneous
100C - 120C / Components List
Description
100C-1
100C-2
100C-3
100C-4
110C-1
110C-2
110C-3
110C-4
120C-1
120C-2
120C-3
120C-4
WHR Unit Size-Pieces Per Unit
Part
Number
*Expansion Valve, Thermostatic Controlled
70 Ton, 1-1/8” In, 1-3/8” Out, 60” Long Cap Tube
024029502 2 2 2 2 2 2 2 2 2 2 2 2
**Solenoid Valve, Liquid Line, In-Line
58 Ton, 1-1/8” ODF, Connections
02532760022 222 2 222 222
Solenoid Valve, Liquid Line, Pilot
1/4” Flare x 1/4” Flare x 1/4” Flare (Three-way), 120V
027517500 2 2 2 2 2 2 2 2 2 2 2 2
Pressure Relief Valve, 450 PSI
039441300224224224
Purge Valve, Shutoff, 1/4” Connections
001360100224224224
Liquid Line Shutoff Valve, Manual
1-1/8” ODS Connections with 1/4” Gauge Port
019282100 1 1 1 1 1 1
1-5/8” ODS Connections with 1/4” Gauge Port
033036200 2 2 2
7/8” ODM End and 3/4” ODS Side Connections 001360000 1 1 1
Liquid Indicator, Saddle Type, Two Piece
Cap
02242770022 222 2 222 222
Body, 1-1/8” ODS Connections
02243110022 222 2 222 222
Filter-Drier Core, Element Replacement
3-3/4” Diameter x 5-1/2” Long, 48 Cubic Inch00136080044 444 4 444 444
Filter-Drier Shell
1-1/8” ODF Connections, 96 Cubic Inch
01919050022 222 2 222 222
Optional Hot Gas Bypass Modulating Pressure Valve (Code 12=1)
1-1/8” ODF Connections, 60” Long Cap Tube
022973500 1 1 1 1 1 1 1 1 1 1 1 1
Optional Hot Gas Bypass Solenoid Valve (Code12=1)
1-1/8” ODF Connections, 120V, 39 Ton, 031007405 1 1 1 1 1 1 1 1 1 1 1 1
Optional Receivers, (Code 03=2)
2-1/8” ODS Connections, 10-3/4” Diameter x 96” Long
02666950021
2-1/8” ODS Connections, 12-3/4” Diameter x 96” Long
02666960012
Optional Discharge Line Muffler (Code 13=1)
1-5/8” ODS Connections
025687400222222
Optional Gauges (Code 07=A)
1/8” NPT, 30-150 Lbs., Suction Pressure Gauge
017503500 2 2 2 2 2 2 2 2 2 2 2 2
1/8” NPT, 30-150 Lbs., Oil Presure Gauge
017503500 4 4 4 4 4 4 4 4 4 4 4 4
1/8” NPT, 800 Lbs., High Pressure Gauge
040159300 2 2 2 2 2 2 2 2 2 2 2 2
Valve, Gauge Shutoff
02838850088 888 8 888 888
Water Flow Switch
01750330011 111 1 111 111
Lock Cylinder and Key
00115720011 111 1 111 111
Paint, Touch-up, Light Gray, (Appears Tan), 12-Ounce Aerosol802083003
Notes: *Units built before August,1980 used 40 ton (Sporlan No. OVE-40-CP-100). Recommended replacement is 30 ton valve listed. New 30 ton valve is directly interchangeable with old 40 ton valve.
** Units with engineering revision number 02 and greater have in-line solenoid valves. Engineering revision number 01 has pilot valves. The change to in-line solenoid valves occured approximately October, 1982.
SeasonPak Water Chillers/WHR 7-1/2 thru 120 Tons, Vint. C
Rev. H 12/2013
RPL 055224300 / Page 39
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement