Level Measurement - Mercado

Level Measurement - Mercado
5
© Siemens AG 2011
Level Measurement
5/2
Product overview
5/7
Point level measurement
Capacitance switches
5/10
– Pointek CLS100
5/16
– Pointek CLS200 – Standard
5/25
– Pointek CLS200 – Digital
5/34
– Pointek CLS200 – Standard and Digital
5/42
– Pointek CLS300 – Standard
5/50
– Pointek CLS300 – Digital
5/57
– Pointek CLS300 – Standard and Digital
5/64
– Pointek CLS500
5/79
– Pointek CLS Specials
Vibrating switches
5/81
– SITRANS LVL100
5/87
– SITRANS LVL200
5/103
– SITRANS LVS100
5/106
– SITRANS LVS200
Rotating paddle switches
5/115
– SITRANS LPS200
Tilt switch
5/127
– Tilt switch Probe
5/129
Ultrasonic switch
5/133
– Pointek ULS200
5/138
Continuous level measurement
Ultrasonic transmitters
– The Probe
5/141
– SITRANS Probe LU
5/202
Continuous level measurement
(continued)
Radar transmitters
5/205
– SITRANS Probe LR
5/209
– SITRANS LR200
5/220
– SITRANS LR200 Antennas
5/223
– SITRANS LR200 Specials
5/226
– SITRANS LR250
5/235
– SITRANS LR250 Specials
5/236
– SITRANS LR250 threaded PVDF antenna
5/243
– SITRANS LR260
5/248
– SITRANS LR400
5/255
– SITRANS LR400 Specials
5/256
– SITRANS LR460
5/261
– SITRANS LR260/LR460 Specials
5/262
– SITRANS LR560
5/267
– SITRANS LR560 Specials
5/268
Guided wave radar transmitters
5/271
– SITRANS LG200
Capacitance transmitters
5/297
– SITRANS LC300
5/311
– SITRANS LC500
5/336
– SITRANS LC300/LC500 Specials
5/337
Continuous level measurement –
Open channel flow
Ultrasonic controller
– OCM III
Communication
SmartLinx module
Dolphin Plus Software
Ultrasonic controllers
5/146
– HydroRanger 200
5/341
5/150
– MultiRanger 100/200
5/343
5/154
– HydroRanger Plus
5/159
– SITRANS LUC500
5/164
– SITRANS LU01 and LU02
5/168
– SITRANS LU10
5/172
– SITRANS LU SAM
5/174
– SITRANS LU AO
5/177
– ST-H
5/180
– Echomax XRS-5
5/183
– Echomax XPS and XCT
5/193
– Echomax XLT
Ultrasonic transducers
Accessories for ultrasonic
5/196
– EA aiming devices
5/198
– FMS mounting brackets
5/200
– TS-3 temperature sensor
You can download all instructions,
catalogs and certificates for SITRANS L
free of charge: www.siemens.com/level
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Product overview
■ Overview
Application
Device description
Page
Programming
Software
Point level measurement - Capacitance switches
Powerful range of level
Pointek CLS100/CLS200/CLS300/CLS500
switches suitable for a variety • CLS100: compact 2-wire inverse frequency shift
5/10
of industries
capacitance switch for level detection in constricted
spaces, interfaces, solids, liquids, slurries, and foam
5
-
• CLS200: a versatile inverse frequency shift
capacitance level switch with optional rod/cable
choices and configurable output, ideal for
detection of liquids, solids, slurries, foam, and
interfaces; digital version (with PROFIBUS PA)
includes a display and provides additional
diagnostic features
5/16
SIMATIC PDM
• CLS300: inverse frequency shift capacitance
level switch with optional rod/cable choices and
configurable output. It is ideal for detecting liquids,
solids, slurries, foam, and interfaces in demanding
conditions where high pressure and temperatures
are present; digital version (with PROFIBUS PA)
includes a display and provides additional
diagnostic features
5/42
SIMATIC PDM
• CLS500: inverse frequency shift capacitance
5/64
level switch for detecting interfaces, solids, liquids,
toxic and aggressive chemicals in critical conditions
of high temperature and pressure; HART communication for remote commissioning
SIMATIC PDM
Point level measurement - Vibrating switches
Reliable vibrating point
SITRANS LVL100/LVL200
level switches for liquid
• LVL100: compact vibrating level switch for use in
5/81
and slurry applications across liquid and slurry applications such as overflow, high,
all industries
low, and demand level applications. Also ideal for
dry run protection.
• LVL200: advanced vibrating level switch for use
5/87
in liquid and slurry applications. Suited for most hazardous area applications such as: overflow, high,
low, demand, and dry run protection; can also be
used for SIL-2 Safety Functions in terms of
IEC 61511-1 First Edition 2003-01.
Reliable vibrating point level SITRANS LVS100/LVS200
switches for bulk solids in a
• Vibrating point level switch designed to be
wide variety of applications at
impervious to external vibrations and to provide
a competitive price
reliable performance in demanding bulk solids
applications.
-
-
5/103
5/106
-
Reliable rotating point level
SITRANS LPS200
5/115
switches for bulk solids in a
• LPS200: rotating paddle switch for detection of high,
wide variety of applications at
low, and demand levels for a wide variety of bulk sola competitive price
ids industries. Unique engineering provides longlasting reliable performance.
-
Point level measurement - Rotating paddle switch
5/2
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Product overview
Application
Device description
Page
Programming
Software
Electro-mechanical tilt switch Tilt Switch Probe
for point level detection,
• Rugged, stainless steel encapsulated probe
plugged chute detection, and
• Provides a signal when material tilts it through an
feed loss detection on conangle of more than 17 ° in any direction.
veyor belts.
5/127
-
5/133
-
Point level measurement - Tilt switch
Point level measurement - Ultrasonic switch
Ultrasonic non-contacting
switch with two switch points
for level detection of bulk
solids, liquids and slurries in
a wide variety of industries
Pointek ULS200
• Rugged design, no moving parts, and virtually
maintenance-free
• Transducer available in ETFE or PVDF copolymer
and therefore inert to most chemicals
-
5
Continuous measurement - Ultrasonic transmitters
Compact level transmitter with The Probe
5/138
integrated transducer for
• Simple, compact and competitively priced ultrasonic
accurate level measurement
level transmitter in several versions for maximum verfor liquid applications
satility:
- Three-wire system with 5 m model 24 V DC
- Two-wire system with current loop
-
2-wire loop powered
ultrasonic transmitter for level,
volume, and flow monitoring
of liquids in open channels,
storage vessels and simple
process vessels
SIMATIC PDM
SITRANS Probe LU
5/141
• Continuous level measurement up to 12 m (40 ft) range
• Patented Sonic Intelligence signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression
Continuous measurement - Ultrasonic controllers
Ultrasonic level controller
for up to six pumps - control,
differential control and open
channel flow monitoring
HydroRanger 200
5/146
• An economical, low-maintenance solution delivering
control efficiency and productivity needed to meet
today’s exacting standards
SIMATIC PDM
• Auto False-Echo Suppression
Versatile short- to mediumMultiRanger 100/200
5/150
range ultrasonic single- and • Using non-contacting ultrasonic technology, the condual-vessel level controller for
troller measures the level in short to medium range
virtually any application in a
applications up to 15 m (50 ft) of solids, liquids, or
wide range of industries
slurries
SIMATIC PDM
• Auto False-Echo Suppression
Non-contacting,
cost-effective solution for
reliable control of level and
flow measurements in water
and wastewater applications
5/154
HydroRanger Plus
• Available as 19" rack, for panel mounting
or in wall enclosure
Dolphin Plus
• Compatible with Echomax ultrasonic transducers
Siemens FI 01 · 2012
5/3
© Siemens AG 2011
Level Measurement
Product overview
Application
Device description
Page
Programming
Software
Complete ultrasonic level
controller for monitoring and
control of water distribution
and wastewater collection
systems, with energy-saving
algorithms
SITRANS LUC500
• Monitoring and control in one device
5/159
Dolphin Plus
Ultrasonic long-range level
monitoring system for liquids
and solids
SITRANS LU01/LU02/LU10
• Automatic conversion of level into volume
for standard or custom tank shapes
5/164
5/168
Dolphin Plus
• Integral telemetry interface (Modbus RTU/ASCII)
• Expandable platform to handle any liquid application
from tank level measurement to pump control
• Easy to install and program
• Optional fieldbus card, e.g. PROFIBUS DP
Output modules for
SITRANS LU10
5
SITRANS LU SAM/SITRANS LU AO
• SITRANS LU SAM satellite alarm module provides up 5/172
to 20 relay contacts for the measurement points connected to a SITRANS LU10
-
• SITRANS LU AO analog output module provides
5/174
remote analog outputs for the measurement points of
the SITRANS LU10 transceiver
-
ST-H: ETFE or PVDF
transducer for chemicals
ST-H/Echomax XRS-5
• The narrow design of the ST-H allows the sensor
to be mounted using a 2" connection
-
XRS-5: Standard transducer
for applications to 8 m (26 ft)
• XRS-5: narrow beam angle of only 10°,
measuring range maximum 8 m (26 ft) for
measurement of liquids, solids, and slurries
5/180
-
Transducers for liquids
and bulk solids
Echomax XPS and XCT/XLT
• XPS series offers versions for various distances up to 5/183
40 m (130 ft) and up to a max. temperature of 95 °C
(203 °F)
-
XPS and XCT series: Hermeti- • XCT series for applications at high temperatures, for 5/183
cally sealed PVDF enclosure
measurement of levels at distances up to 12 m (40 ft),
for chemical immunity
and temperatures of max. 145 °C (293 °F)
-
Continuous measurement - Ultrasonic transducers
XLT: Designed for high
temperature and long
range applications
5/177
• XLT: measuring ranges from 0.9 to 60 m
(1.8 to 200 ft) and temperatures up to 150 °C
(302 °F). Beam angle of just 5° provides
accurate readings in solids storage bunkers
5/193
SITRANS Probe LR
• Uni-Construction polypropylene rod antenna
standard
5/205
Continuous measurement - Radar transmitters
2-wire, 6 GHz pulse radar
level transmitter for continuous monitoring of liquids and
slurries in storage vessels
with nominal pressure and
temperature, to a range of
20 m (66 ft)
5/4
Siemens FI 01 · 2012
• Patented Sonic Intelligence signal processing
• Auto False-Echo Suppression
SIMATIC PDM
AMS
© Siemens AG 2011
Level Measurement
Product overview
Application
Device description
2-wire, 6 GHz pulse radar
SITRANS LR200
level transmitter for
• Program without opening the lid, even in
continuous monitoring of
hazardous areas, using patented infrared IS
liquids and slurries in storage
handheld programmer
and process vessels includ• Special Uni-Construction hermetically sealed
ing high temperature and
polypropylene rod antenna has integrated
pressure, to a range of 20 m
threaded connection
(66 ft)
Page
Programming
Software
5/209
SIMATIC PDM
AMS
5/226
SIMATIC PDM
AMS
5/243
SIMATIC PDM
• Built-in alphanumeric display with support in
four languages
2-wire, 25 GHz pulse radar
level transmitter for
continuous monitoring of
liquids and slurries in storage
and process vessels including high temperature and
pressure, to a range of 20 m
(66 ft); ideal for small vessels
and low dielectric media
SITRANS LR250
• Simple operation using the graphical
local user interface (LUI)
• Plug-and-play setup using the intuitive
Quick Start Wizard
• 25 GHz high frequency allows for small
horn antennas and easy mounting in nozzels
• Process Intelligence signal processing
for improved measurement reliability and
Auto False-Echo Suppression of fixed obstructions
• Communication using HART, PROFIBUS PA or
FOUNDATION Fieldbus
2-wire, 25 GHz pulse radar
level transmitter for
continuous monitoring
of solids up to 30 m (66 ft);
ideal for measurement in
extreme dust
SITRANS LR260
• Simple operation using the graphical local
user interface (LUI)
• Plug-and-play setup using the intuitive Quick Start
Wizard
• 25 GHz high frequency allows for small horn antennas and easy mounting in nozzels
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo
Suppression of fixed obstructions
• Communication using HART, PROFIBUS PA, or
FOUNDATION Fieldbus
N
4-wire, 24 GHz FMCW
radar level transmitter for
continuous monitoring of
liquids and slurries in
storage and process
vessels including high
temperature and high
pressure, to a range of
50 m (164 ft); ideal for low
dielectric media
SITRANS LR400
• Minimum maintenance requirements and wear
as result of non-contacting measuring principle
5/248
SIMATIC PDM
4-wire, 24 GHz FMCW
radar level transmitter
with extremely high signal-tonoise ratio and advanced signal processing for continuous
monitoring of solids up to
100 m (328 ft); ideal for measurement in extreme dust
SITRANS LR460
5/256
• Process Intelligence for advanced signal processing
and quick and easy adjustment
SIMATIC PDM
• High long-term stability resulting from selfcalibration with highly stable internal reference
• High measuring accuracy and repeatability as result
of 24 GHz; narrow beam angle for tall,
narrow vessels
• Self-guided Quick Start Wizard
for plug and play start-up
• 100 m (328 ft) range for long-range and
difficult applications
2-wire, 78 GHz FMCW
SITRANS LR560
5/262
radar level transmitter for • Rugged stainless steel design for industrial applicacontinuous monitoring of
tions
solids in silos to a range of
•
78
GHz high frequency provides very narrow beam,
100 m (329 ft)
SIMATIC PDM
virtually no mounting nozzle noise, and optimal reflection from sloped solids
• Aimer option to direct beam to area of interest, such
as draw point of cone
• Air purge connection is included for self-cleaning of
extremely sticky solids
• Lens antenna is highly resistant to product build up
• Local display interface (LDI) allows local programming and diagnostics
Siemens FI 01 · 2012
5/5
5
© Siemens AG 2011
Level Measurement
Product overview
Application
Device description
Page
Programming
Software
SITRANS LG200
• Measures accurately on materials
with dielectric (dK) as low as 1.4
5/271
SIMATIC PDM
5/297
-
5/311
SIMATIC PDM
Continuous measurement - Guided wave radar transmitters
Guided wave radar
transmitter for short- and
medium-range level,
level/interface, and volume
measurement of liquids and
solids. It is unaffected by
changes in process conditions, high temperatures and
pressures, and steam.
• Guided wave radar measurement
for up to 2.5 mm (0.12 inch) accuracy
• Measures level and interface
on challenging applications including foam
• 3 button programming for quick setup
• Reliable level measurement on harsh applications
with pressure up to 430 bar g (6250 psi g) and
temperatures as high as 427 °C (800 °F)
Continuous level – Capacitance transmitters
For liquids and solids
applications, ideal for
standard industrial
applications in chemical,
hydrocarbon processing,
food and beverage, and
mining, aggregate and
cement industries
5
SITRANS LC300
• Sophisticated, but easy-to-adjust microprocessor
combined with field-proven probes
• Patented active shield technology ensures
measurements are unaffected by vapors,
product deposits, dust, and condensation
Level and interface
SITRANS LC500
transmitter for extreme
• Equipped with the HART Smart protocol
and critical process
for remote setup and calibration
conditions, such as oil
and liquid natural gas (LNG), • Patented active shield technology ensures
measurements are unaffected by vapors,
toxic and aggressive
product deposits, dust, and condensation
chemicals and vapours
Continuous level - Open channel flow - Ultrasonic controller
High accuracy ultrasonic flow OCM III
monitor for open channels
• Compatible with most standard open
channel weirs and flumes
5/337
• AC and DC operation
• Automatically switches to battery operation
for uninterrupted power
• MCERTS approved device
Communications
SmartLinx Module, Dolphin Plus software
• Optional communication modules, SmartLinx,
5/341
provide direct digital connection to popular industrial
fieldbus systems
• Dolphin Plus for quick and easy configuring,
monitoring, tuning, and diagnostics of Siemens devices
5/6
Siemens FI 01 · 2012
5/343
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Capacitance
■ Overview
■ Mode of operation
Introduction
Common Terms
Inverse frequency shift capacitance point level switches and
continuous level transmitters are designed to withstand the
harsh environments of high pressure and high temperature
applications.
Capacitance
Inverse Frequency Technology
Siemens inverse frequency shift capacitance devices incorporate a unique frequency-based approach to level measurement.
The capacitance units monitor the effect of capacitance based
on frequency change. The relationship between capacitance
and frequency is inverse. Because small level changes result in
a large frequency change, the result is excellent resolution and
accuracy.
Principle of Operation
Inverse frequency shift capacitance devices require two components: a reference electrode of a variable capacitor and the
measurement electrode. In capacitive level measurement, the
environment (typically the vessel wall) acts as the reference
electrode, while the probe supplies the measurement electrode.
The dielectric is composed of the vessel contents and, if the
measurement electrode is insulated, the insulating layer.
The property of a system of conductors and dielectrics that permits the storage of electricity when a potential difference exists
between the conductors. Its value is expressed as the ratio of a
quantity of electricity to a potential difference and the unit is a
Farad.
Capacitor
A device in a circuit that has the potential to store an electric
charge. Typically a capacitor has two conductors or electrodes
separated by a layer of a non-conducting material called a dielectric. With the conductors on opposite sites of the dielectric
layer oppositely charged by a source of voltage, the electrical
energy of the charged system is stored in the polarized dielectric.
Dielectric constant
The ability of a dielectric to store electrical potential energy
under the influence of an electric field. This is measured by a
ratio which compares the capacitance of a condenser with the
material as dielectric to its capacitance with a vacuum/dry air
as dielectric: the dielectric constant of air is 1.
Active shield
Operating Principles
dielectric = contents plus insulation
(non-conductive contents)
dielectric = insulation
(conductive contents)
The portion of the probe isolated from the active measurement
section. The sensor signal is connected to the active shield portion of the probe, eliminating the electrical potential difference
between the shield and the measurement section. So, the shield
portion of the probe near the process connection is not affected
by changes in vapour concentration, material buildup, dust, or
condensation.
probe
dia.
internal
vessel wall
(insulation)
probe
sleeve
internal vessel diameter
Inverse frequency shift capacitance operation
Capacitance is affected by the surface area of the electrodes,
the separation distance between the electrodes and the dielectric constant of the vessel contents. The dielectric constant is
the measure of a material’s ability to store energy. The relative
dielectric constant of air (vacuum) is 1; all other materials have
a higher value.
Siemens FI 01 · 2012
5/7
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Capacitance
■ Technical specifications
Point Level Measurement
5
Continuous Level/
Interface Measurement
Criteria
Pointek CLS100
Pointek CLS200
Pointek CLS300
Pointek CLS500
SITRANS LC300
SITRANS LC500
Typical applications
Liquids, slurries,
powders, granules, applications
in constricted
spaces
Liquids, slurries,
powders, granules, foam, food,
and pharmaceuticals, petrochemicals
Liquids, slurries,
powders, granules, relatively high
pressure and temperature, hazardous areas
Water in oil level,
foam or liquid/
foam level, glycol
regenerators, highpressure coalescers
Conductive or nonconductive liquids, foam, or liquid/foam levels,
water in oil levels
Water in oil, foam
or liquid/foam
level, high-pressure coalescers,
LNG (Liquified
Natural Gas)
Max. length
including sensor
100 mm (4 inch)
Rod: 5.5 m (18 ft)
Cable: up to 30 m
(98 ft)
Rod: 1 m (40 inch)
Cable: 25 m (82 ft)
Rod: 1 m (40 inch)
Rod: 5 m (18 ft)
Cable: 25 m (82 ft)
Rod: 5.5 m (18 ft)
Cable: 35 m
(115 ft)
Process temperature (Temperature
ratings are pressure
dependent.
See Pressure/
Temperature curves
for respective
product.)
• Stainless steel
process connection:
-30 ... +100 °C
(-22... +212 °F)
• Fully Synthetic
(PPS process
connection):
-10 ... +100 °C
(+14 ... +212 °F)
• -40 ... +85 °C
(-40 ... +185 °F)
• With thermal
isolator:
-40 ... +125 °C
(-40 ... +257 °F)
• -40 ... +200 °C
(-40 ... +392 °F)
• HT version:
-40 ... +400 °C
(-40 ... +752 °F)
• -50 ... +200 °C
(-58 ... +392 °F)
• HT version:
-60 ... +400 °C
(-76 ... +752 °F)
-40 ... +200 °C
(-40 ... +392 °F)
• -50 ... +200 °C
(-58 ... +392 °F)
• Option:
-60 ... +400 °C
(-76 ... +752 °F)
Process pressure
(Pressure ratings are
temperature dependent.
See Pressure/
Temperature curves
for respective
product.)
Up to 10 bar g
(146 psi g)
• Rod versions:
Up to 25 bar g
(365 psi g)
• Cable version:
Up to 10 bar g
(146 psi g)
Up to 35 bar g
(511 psi g)
• Up to 150 bar g
(2175 psi g)
• HP version:
Up to 345 bar g
(5004 psi g)
Up to 35 bar g
(511 psi g)
• Up to 150 bar g
(2175 psi g)
• Option:
Up to 345 bar g
(5004 psi g)
Output
Stainless steel
cable or enclosure
version:
• 4 ... 20/
20 ... 4 mA
2-wire current
loop
• Solid-state output
Fully-synthetic
version (PPS)
• Relay output
Standard:
• 1 SPDT Form C
relay, solid-state
switch
Digital:
• solid-state switch
included
Standard:
• 1 SPDT Form C
relay, solid-state
switch
Digital:
• solid-state switch
included
• 4 to 20/20 to
4 mA 2-wire
current loop
• Solid-state switch
4 to 20/20 to 4 mA
2-wire current loop
• 4 to 20/20 to
4 mA 2-wire
current loop
• Solid-state switch
• Standard: 3 LED
indicators
• Digital: PROFIBUS PA;
SIMATIC PDM
compatible
• Standard: 3 LED
indicators
• Digital: PROFIBUS PA;
SIMATIC PDM
compatible
HART, SIMATIC
PDM
compatible
Communications
HART, SIMATIC
PDM
compatible
Power
Specifications
• Standard:
12 ... 33 V DC
• Intrinsically Safe
(Stainless steel
version only):
10 ... 30 V DC
• Standard: 12 ...
250 V AC/DC,
0 ... 60 Hz,
2 W max.
• Digital:
- bus voltage:
12 ... 30 V DC,
IS version
12 ... 24 V DC
- current consumption:
12.5 mA
• Standard: 12 ...
250 V AC/DC,
0 ... 60 Hz,
2 W max.
• Digital:
- bus voltage:
12 ... 30 V DC,
IS version
12 ... 24 V DC
- current consumption:
12.5 mA
• 12 ... 33 V DC
• 3.6 ... 22 mA/
22 ... 3.6 mA
(2-wire current
loop)
12 to 32 V DC any
polarity, 2-wire current loop circuit
• 12 ... 33 V DC
• 3.6 ... 22 mA/
22 ... 3.6 mA
(2-wire current
loop)
Approvals
Stainless steel
cable or enclosure
version:
CE, CSA, FM,
ATEX, C-TICK,
Lloyds Register,
WHG
Fully-synthetic
version (PPS):
CSA, FM
CSA, FM, CE,
ATEX, C-TICK,
Lloyds Register,
WHG, Vlarem II
CSA, FM, CE,
ATEX, C-TICK,
Lloyds Register,
WHG, Vlarem II
CE, CSA, FM,
ATEX, C-TICK,
Lloyds Register,
Bureau Veritas,
Current Signalling
according to
NAMUR NE 43
CE, CSA, FM,
ATEX, C-TICK,
Bureau Veritas,
ABS, Current
Signalling according to
NAMUR NE 43
CE, CSA, FM,
ATEX, C-TICK,
Lloyds Register,
Bureau Veritas,
Current Signalling
according to
NAMUR NE 43
5/8
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Capacitance
5
Siemens FI 01 · 2012
5/9
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
■ Overview
■ Configuration
Installation
20 (0.79) max.
Standpipes
≥ 50 (2)
Wall Restriction
Pointek CLS100 is a compact 2-wire inverse frequency shift
capacitance switch for level detection in constricted spaces,
interfaces, solids, liquids, slurries and foam.
■ Benefits
•
•
•
•
•
Easy installation with verification by built-in LED
Low maintenance with no moving parts
Sensitivity adjustment
Integrated cable or PBT enclosure versions available
Intrinsically Safe, Dust Ignition Proof, and General Purpose
options available
■ Application
Pointek CLS100’s short insertion length of 100 mm (4 inch) and
versatility in various applications and in vessels or pipes makes
it a good replacement for traditional capacitance sensors.
Its advanced tip-sensing technology provides accurate, repeatable switchpoint performance. The PPS (Polyphenylene sulfide)
probe [optional PVDF (Polyvinylidene Fluoride)] is chemically
resistant with an effective process operating temperature range
from -30 to +100 °C (-22 to +212 °F) (7ML5501), and
-10 to +100 °C (+14 to +212 °F) (7ML5610). The fully potted
design ensures reliability in a vibrating environment such as
agitated tanks up to 4 g. When used with a SensGuard protection cover, the CLS100 is protected from shearing, impact, and
abrasion in tough primary processes.
The Pointek CLS100 is available in three versions. The integral
cable version has a stainless steel process connection and
probe options of PPS or PVDF. The fully synthetic version has a
thermoplastic polyester enclosure with a PPS process connection combined with a PPS probe. The standard enclosure version
has a thermoplastic polyester enclosure with a stainless steel
process connection in combination with a PPS or PVDF probe.
• Key Applications: liquids, slurries, powders, granules, food
and pharmaceuticals, chemicals, hazardous areas
5/10
Siemens FI 01 · 2012
50 (2)
min.
50 (2)
5
Pointek CLS100 installation, dimensions in mm (inch)
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
■ Technical specifications
Stainless steel
process connection
(integral cable or
enclosure version)
(7ML5501)
Fully synthetic
process connection
(enclosure version
only) (7ML5610)
Stainless steel
process connection
(integral cable or
enclosure version)
(7ML5501)
Fully synthetic
process connection
(enclosure version
only) (7ML5610)
Inverse frequency
shift capacitive level
detection
Inverse frequency
shift capacitive level
detection
Process connection
material of probe/
wetted parts3)
Connection: 316L
stainless steel;
Process seal: FKM
(optional FFKM);
Sensor: PPS
(optional PVDF)4)
PPS process connection and PPS sensor
(Uni-Construction)
Change in picoFarad
(pF)
Change in picoFarad
(pF)
Connection
(Enclosure version)
Internal 5-point
terminal block,
½" NPT wiring
entrance,
M20x1.5 optional
Removable internal
5-point terminal
block, ½" NPT wiring
entrance,
M20 x 1.5 optional
4 ... 20/20 ... 4 mA
2-wire loop
Solid-state: 30 V DC/
30 V AC, max. 82 mA
Connection
(Integral cable version)
4 conductors, 1 m
(3.3 ft), 0.5 mm²
(22 AWG), shielded,
polyester jacket
Not applicable
Process connection
Min. or max.
4 ... 20/20 ... 4 mA
2-wire loop
Max. switching
voltage: 60 V DC/
30 V AC
Max. switching
current: 1 A
Min. or max.
¾" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1"
[(BSPT), EN 10226/PT
(JIS-T), JIS B 0203]
2 mm (0.08 inch)
2 mm (0.08 inch)
¾" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1"
[(BSPT), EN 10226/PT
(JIS-T), JIS B 0203]
G 1" [(BSPP),
EN ISO 228-1/PF
(JIS-P), JIS B 0202]
Mode of operation
Measuring principle
Input
Measured variable
Output
Output signal
• Alarm output
• Switch output1)
• Fail-safe mode
Accuracy
Repeatability
Rated operating
conditions2)
Installation conditions
• Location
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
Medium conditions
• Relative dielectric
contant εr
• Process temperature
• Pressure (vessel)
Power supply
Standard
12 ... 33 V DC
12 ... 33 V DC
Indoor/outdoor
Indoor/outdoor
Intrinsically Safe
Not applicable
-30 ... +85 °C
(-22 ... +185 °F)
I
4
-10 ... +85 °C
(+14 ... +185 °F)
I
4
10 ... 30 V DC
(Intrinsically Safe
barrier required)
Certificates and
approvals
Min. 1.5
Min. 1.5
-30 ... +100 °C
(-22 ... +212 °F)
-1 ... +10 bar g
(-14.6 ... +146 psi g),
nominal2)
-10 ... +100 °C
(+14 ... +212 °F)
-1 ... +10 bar g
(-14.6 ... +146 psi g),
nominal
IP68/Type 4/NEMA 4
IP65/Type 4/NEMA 4
IP68/Type 4/NEMA 4
Not applicable
½" NPT
(M20x1.5 optional)
½" NPT
(M20x1.5 optional)
Enclosure/Integral
cable version
Fully synthetic version
General: CE, CSA,
General: CSA, FM
FM, C-TICK
Marine: Lloyds Register of Shipping, categories ENV1, ENV2,
and ENV5
Dust Ignition Proof
(barrier required):
CSA/FM Class II and
III, Div. 1, Groups E, F,
G T4
Intrinsically Safe
(barrier required):
CSA/FM Class I,
II and III, Div. 1,
Groups A, B, C, D, E,
F, G T4
ATEX II 1 GD 1/2GD
EEx ia IIC T4 to
T6 T107 °C
Overfill protection:
WHG (Germany)
• Degree of protection
- Enclosure version
- Integral cable
version
• Cable inlet
Design
Material
• Body
(Enclosure version)
• Lid
(Enclosure version)
• Integrated cable body
(Integral cable
version)
Sensor length
(nominal)
1)
Thermoplastic
polyester
Transparent thermoplastic polycarbonate (PC)
316L stainless steel
Thermoplastic
polyester
Transparent thermoplastic polycarbonate (PC)
Not applicable
100 mm (4 inch)
100 mm (4 inch)
When synthetic process connection version (7ML5610) is used in wet
locations, switching voltage of the relay is limited to 35 V DC/16 V AC.
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 5/14.
3) For Caustic Materials please contact [email protected]
http://www.siemens.com/automation/support-request
for alternative O Rings
4)
When FFKM O-ring (Option A22) is selected, process temperature is
restricted to -20 °C (-4 °F).
2)
Siemens FI 01 · 2012
5/11
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
Selection and Ordering data
Selection and Ordering data
Pointek CLS100, PPS process connection
Compact 2-wire inverse frequency shift capacitance switch for level detection in constricted
spaces, interfaces, solids, liquids, slurries and
foam
Process connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
A
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
E
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
J
Process connection (PPS)
¾" NPT [(Taper), ANSI/ASME B1.20.1]
(PPS probe body)
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
(PPS probe body)
Approvals
General Purpose: CE, CSA, FM, C-TICK
CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D,
E, F, G T4; ATEX II 1 GD 1/2GD EEx ia IIC T4 to
T6 T107 °C 1)
CSA/FM Class II and III, Div. 1, Groups E, F, G1)
5
Order No.
C) 7ML5501Pointek CLS100, stainless steel process
connection
0 7777
Compact 2-wire inverse frequency shift capacitance
switch for level detection in constricted spaces,
interfaces, solids, liquids, slurries and foam
Approvals
General Purpose: CSA, FM
A
C
G
1
Enclosure version (PPS probe), ½" NPT cable inlet
3
Integral cable version with PVDF probe body
5
Enclosure version with PVDF probe body
(½" NPT cable inlet)
Enclosure version (PPS probe), M20x1.5 cable inlet
6
Enclosure version with PVDF probe body,
M20x1.5 cable inlet
8
Selection and Ordering data
7
Required
1
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
C) Subject to export regulations AL: N, ECCN: EAR99.
Selection and Ordering data
Order code
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text
Y17
FFKM seal O-ring1)
A22
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Order No.
Quick start manual, multi-language
Note: due to ATEX regulations one Quick start manual
is included with every product.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
Operating Instructions.
7ML1998-5QJ82
Optional equipment
Sensguard, ¾" NPT (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DL
Sensguard, R 1" (BSPT) (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DM
Siemens Intrinsically Safe Barrier (DC powered),
ATEX II 1 G EEx ia
7NG4124-0AA00
½" NPT cable gland, nickel plated brass, fits cable
diameter 6 ... 12 mm (0.24 ... 0.47 inch)
-40 ... +100 °C (-40 ... +212 °F), IP68 (General Purpose)
7ML1830-1JA
M20x1.5 cable gland, PA polyamide,
ATEX II 2G EEx e II, fits cable diameter 7 ... 12 mm
(0.28 ... 0.47 inch), -20 ... +70 °C (-4 ... +158 °F),
IP68 (General Purpose)
7ML1830-1JC
See Temperature restriction on page 5/14
5/12
Siemens FI 01 · 2012
B
D
1
2
Order code
Please add "-Z" to Order No. and specify Order
code(s).
0
1)
A
Further designs
WHG approval, German overfill protection
Not required
Further designs
0 77 0
Versions/Options
Enclosure version, PPS process connection,
½" NPT cable inlet
Enclosure version, PPS process connection,
M20x1.5
Device version
Integral cable version (PPS probe)
1)
Order No.
C) 7ML5610-
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/identification (max. 20 characters) specify in plain text
Y17
FFKM seal O-ring1)
A22
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Order No.
Quick start manual, multi-language
Note: due to ATEX regulations one Quick start manual
is included with every product.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
Operating Instructions.
7ML1998-5QJ82
Optional equipment
Sensguard, ¾" NPT (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DL
Sensguard, R 1" (BSPT) (PPS)
Only available for CLS100 with ¾" NPT thread
7ML1830-1DM
1)
See Temperature restriction on page 5/14
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
■ Options
process
connection
R 1" (BSPT)
70 (2.75)
32
(1.26)
91 (3.6)
process
connection
¾" NPT
70 (2.75)
91 (3.6)
32
(1.26)
Optional Sensguard
internal thread ¾" NPT
Optional Sensguard, dimensions in mm (inch)
5
Siemens FI 01 · 2012
5/13
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
■ Characteristic curves
Pressure/Temperature Curve
CLS100
Threaded Process Connections
(7ML5501)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-22 ºF 14 ºF
(-30 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
5
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted Operating Temperature T
Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C
Pointek CLS100 Process Pressure/Temperature derating curves
■ Dimensional drawings
Enclosure Version
36 (1.4) nominal*
1
2
Cable relief
5
Sensor status
LED (yellow)
Terminal block
ground lug
72.5 (2.9)
*Some G thread configurations deviate from this size.
Pointek CLS100 dimensions, dimensions in mm (inch)
Siemens FI 01 · 2012
Process connection
98 (3.9)
nominal
98 (3.9)
nominal
120 (4.7)
Process connection
5/14
Cable inlet ½" NPT
(optional M20x1.5)
Output status
LED (red)
50
(2.0)
Sensitivity trimpot
Cable Ø 5 (0.2)
Trimpot cap
Output status
LED (red)
Sensor status
LED (yellow)
3
4
120 (4.7)
204 (8.0)
Ground post
Power LED (green)
80 (3.2)
Power LED (green)
Sensitivity trimpot
65 (2.6)
Integral Cable Version
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS100
■ Schematics
Integral Cable Version - Non Intrinsically Safe only
LOW/HIGH Alarm
white
white
Polarity as required
for
desired operation
black
12 ... 33 V DC
red
4/20 mA Loop Alarm
white
white
black
Rmax = Vsupply - 10 V
20 mA
red
V supply
12 ... 33 V DC
Solid State Switch Version
white
white
Solid state switch,
30 V DC/AC
(peak) 82 mA (max)
black
red
V supply
12 ... 33 V DC
5
Enclosure and Fully Synthetic Version
1
2
3
4
5
Terminal operations
Cable equivalent
mAcurrent loop (+V or -V)
mAcurrent loop (+V or -V)
ground
solid state switch/relay*
solid state switch/relay*
red wire
black wire
cable shield
white wire
white wire
* switch/relay normally open in unpowered state
* relay not available on Pointek CLS100 IS version (7ML5501)
Note:
When driving an inductive load (for example, an external relay), a protection diode
must be connected in the correct polarity to prevent possible switch damage due to
inductive spikes generated by switching the inductor (please refer to instruction
manual). Intrinsically Safe Models - please follow local regulations and area
classifications; refer to instruction manual for more details.
Pointek CLS100 connections
Siemens FI 01 · 2012
5/15
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
■ Overview
■ Configuration
Installation
5
Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable
choices, and configurable output, ideal for detection of liquids,
solids, slurries, foam, and interfaces.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity, and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency
oscillation
• 3 LED indicators for sensor status, output status, and power
Avoid areas where material build up occurs.
■ Application
Pointek CLS200 standard version has 3 LED indicators with
basic relay, and solid-state switch alarms.
m
in
.5
0
)
(2
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 250 V AC/DC). When used with thermal
isolator, the stainless steel and PPS (PVDF optional) materials
used in the probe construction provide a temperature rating up
to +125 °C (+257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency, and
it can be set to detect before contact or on contact with the
probe. The CLS200 operates independently of the tank wall or
pipe so it does not require an external reference electrode for
level detection in a non-conductive vessel such as concrete or
plastic (EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas
Install probe at least 50 (2) from tank wall.
Pointek CLS200 installation, dimensions in mm (inch)
5/16
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
■ Technical specifications
Mode of operation
Measuring principle
Design
Inverse frequency shift capacitive level detection
Input
Measured variable
Change in picoFarad (pF)
Output
Output signal
• Relay output
- Max. contact voltage
- Max. contact current
- Max. switching capacity
- Time delay (ON and/or OFF)
• Solid-state output
- Output
- Protection
- Max. switching voltage
- Max. load current
- Voltage drop
- Time delay (pre or post
switching)
1 SPDT Form C relay
• 30 V DC
• 250 V AC
• 5 A (DC)
• 8 A (AC)
150 W (DC)
2000 VA (AC)
1 to 60 s
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
1 to 60 s
Rated operating conditions1)
Material
• Enclosure
• Optional thermal isolator
Epoxy-coated aluminum with
gasket
316L stainless steel
Connection
Removable terminal block,
max. 2.5 mm²
Degree of protection
IP65/Type 4/NEMA 4
(optional IP68)
Cable inlet
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
Power supply
12 to 250 V AC/DC, 0 ... 60 Hz
max. 2 W
Certificates and approvals
General Purpose
CSA, FM, CE, C-TICK
Dust Ignition Proof
ATEX II 1/2 D T100°C
Flameproof Enclosure With IS Probe
ATEX II 1 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure
With IS Probe
CSA/FM Class I, Div. 1, Gr. A, B,
C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Installation conditions
• Location
Indoor/outdoor
Marine
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +85 °C (-40 ... +185 °F)2)
II
4
Lloyds Register of Shipping,
Categories ENV1,
ENV2 and ENV5
Overfill Protection
WHG (Germany)
VLAREM II
Liquids, bulk solids, slurries and
interfaces
Min. 1.5
Others
Pattern Approval (China)
1)
Medium conditions
• Relative dielectric constant εr
• Process temperature
- Without thermal isolator
- With thermal isolator
• Process pressure (rod version)
• Process pressure (cable version)3)
• Process pressure (sliding coupling
version)
Electromagnetic Compatibility
-40 ... +85 °C (-40 ... +185 °F)2)
-40 ... +125 °C (-40 ... +257 °F)
-1 ... +25 bar g
(-14.6 ... +365 psi g) (nominal)
-1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
-1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 5/35.
2) Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F).
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves on page 5/35.
To comply with CE EMC regulations (where applicable); the
CLS200 should be installed per
the instruction manual.
Siemens FI 01 · 2012
5/17
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
Design: Probe
Sanitary version
Cable version
Sliding Coupling version
Max. length
5500 mm (216.53 inch)
5500 mm (216.53 inch)
30000 mm (1181.1 inch)
liquids and slurries
5000 mm (196.85 inch)
solids (under loads)
5500 mm (216.53 inch)
Process connection
R ¾", 1", 1¼", 1½"
[(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
316L stainless steel
ASME/EN flange
1½", 2" sanitary fitting
clamp
316L stainless steel
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
316L stainless steel
ASME/EN flange
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Extension material
316L stainless steel
optional PFA coated1)
316L stainless steel
Fluoroethylene propylene
(FEP) cable with stainless
steel core
316L stainless steel
Sensor wetted parts
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
O-ring seal material
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
Optional
Optional
Optional
Optional
User selected length
User selected length
Cable extension
User selected length
Thermal
isolator3)
Extension
1)
PFA coating (7ML5634 and 7ML5644) has 120 micron thickness.
2)
For Caustic Materials please contact [email protected] for alternative O-Rings.
3) Thermal isolator is used if process connection temperature exceeds +85 °C (+185 °F).
■ Options
Optional Sensguard, dimensions in mm (inch)
5/18
Siemens FI 01 · 2012
process
connection
R 1" (BSPT)
70 (2.75)
32
(1.26)
91 (3.6)
process
connection
¾" NPT
70 (2.75)
32
(1.26)
Optional Sensguard
internal thread ¾" NPT
91 (3.6)
5
Rod version
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Pointek CLS200 - Standard - Rod Version with C)
Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
Order No.
7ML56307 7 7 77 - 777 0
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
0D
1A
1B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1D
3A
3B
3D
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6A
6B
6C
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
6G
6H
6J
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
Compact [threaded 120 mm (4.72 inch),
Flanged 98 mm (3.86 inch)]
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
6K
0A
0B
0C
5A
5B
5C
Selection and Ordering data
Order No.
Pointek CLS200 - Standard - Rod Version with C) 7ML5630Threaded or Flanged process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 210 ... 1000 mm (8.27 ... 39.37 inch)
M
Extended rod, 1001 ... 2000 mm
N
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
P
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
Q
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
R
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
S
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
0
With thermal isolator [for process connection
1
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable1)
2
With 5 m (197 inch) of cable1)
3
Wetted seals
FKM
0
FFKM [for process temperatures above -20 °C (-4 °F)]
1
Probe material
316L Stainless Steel with PPS probe body
316L Stainless Steel with PVDF probe body
A
B
C
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
D
E
F
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
G
H
J
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
K
L
Approvals
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
General Purpose (CE, C-TICK)
General Purpose (CSA, FM, CE, C-TICK) with WHG
approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20 x 1.5 cable inlet IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20 x 1.5 cable inlet IP68
0
1
C
D
E
F
G
H
J
K
A
B
C
D
1)
Available with Approvals options F to H and K only
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/19
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
5
5/20
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Pointek CLS200 - Standard - Cable Version with C)
Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices and
configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
Extended cable, 3000 mm (118.11 inch), length can
be determined by customer on assembly
Extended cable, 6000 mm (236.22 inch), length can
be determined by customer on assembly
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 5000 mm
(19.69 ... 196.85 inch)
Extended cable, 5001 ... 10000 mm
(196.89 ... 393.70 inch)
Extended cable, 10001 ... 15000 mm
(393.74 ... 590.55 inch)
Extended cable, 15001 ... 20000 mm
(590.59 ... 787.4 inch)
Extended cable, 20001 ... 25000 mm
(787.44 ... 984.25 inch)
Extended cable, 25001 ... 30000 mm
(984.29 ... 1181.1 inch)
Order No.
7ML56317 7 7 77 - 777 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
Selection and Ordering data
Order No.
Pointek CLS200 - Standard - Cable Version with C) 7ML5631Threaded or Flanged process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices and
configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Thermal isolator
Without thermal isolator
0
With thermal isolator [for process connection tempe1
ratures over +85 °C (+185 °F)]
Remote mount electronics and mounting
bracket
With 2 m (79 inch) of cable1)
2
With 5 m (197 inch) of cable1)
3
Wetted seals
FKM and PTFE
0
FFKM and PTFE [for process temperatures above
1
-20 °C (-4 °F)]
Probe material
FEP jacketed cable with PPS probe body
0
FEP jacketed cable with PVDF probe body
1
Approvals
Dust Ignition Proof:
C
CE, C-TICK, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
D
CE, C-TICK, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
E
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
F
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
G
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
H
General Purpose (CE, C-TICK)
J
General Purpose (CSA, FM, CE, C-TICK) with WHG
K
approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
1)
Available with Approvals options F to H and K only
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
A
Total insertion length: enter the total insertion length
in plain text description
Y01
B
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
C
D
E
F
G
H
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and manual library.
See page 5/34
Accessories
See page 5/34
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/21
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
5
Selection and Ordering data
Order No.
Pointek CLS200 - Standard - Rod with Sanitary C) 7ML5632process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Selection and Ordering data
Process connection
Sanitary 316L stainless steel
Approvals
1" sanitary fitting clamp
1½" sanitary fitting clamp
2" sanitary fitting clamp
8A
8B
8C
2½" sanitary fitting clamp
3" sanitary fitting clamp
(Note: Sanitary connection dimensionally corresponds to the applicable ISO 2852 standard)
8D
8E
Order No.
Pointek CLS200 - Standard - Rod with Sanitary C) 7ML5632process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D T100 °C
C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
D
Flameproof Enclosure with IS Probe, with WHG
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
E
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
Probe length (length from process connection
face)
Note: No Y01 needed in order code for
standard lengths
Compact 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
A
B
C
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
D
E
F
General Purpose (CSA, FM)
H
General Purpose (CE, C-TICK)
J
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
G
H
J
General Purpose (CSA, FM, CE, C-TICK) with
WHG approval
K
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
K
L
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch)
Extended rod, 351 ... 1000 mm
(13.82 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
Remote mount electronics with 2 m (79 inch) of
cable1)
Remote mount electronics with 5 m (197 inch) of
cable1)
Wetted seals
FKM
FFKM
[for process temperatures above -20 °C (-4 °F)]
Probe material
316L Stainless Steel with PPS probe body
316L Stainless Steel with PVDF probe body
5/22
Siemens FI 01 · 2012
Enclosure and lid
Aluminum epoxy coated
A
B
C
D
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
M
N
1)
P
C) Subject to export regulations AL: N, ECCN: EAR99.
Q
Selection and Ordering data
Available with Approvals options F to H and K only
Order code
Further designs
R
S
Please add "-Z" to Order No. and specify Order
code(s).
T
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
0
1
2
Operating Instructions
3
0
1
0
1
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
Selection and Ordering data
Order No.
Pointek CLS200 - Standard - Sliding Coupling C)
with Threaded process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
7ML56337 7 7 77 - 777 0
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard lengths
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 350 ... 1000 mm
(13.82 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Remote mount electronics and mounting
bracket
With 2 m (79 inch) of cable1)
With 5 m (197 inch) of cable1)
Wetted seals
FKM and PTFE
FFKM and PTFE [for process temperatures above
-20 °C (-4 °F)]
Probe material
316L Stainless Steel with PPS probe body
316L Stainless Steel with PVDF probe body
Order No.
Pointek CLS200 - Standard - Sliding Coupling C) 7ML5633with Threaded process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Approvals
Dust Ignition Proof:
C
CE, C-TICK, ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe:
D
CE, C-TICK, ATEX II 1 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
E
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
F
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
G
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
H
General Purpose (CE, C-TICK)
J
General Purpose (CSA, FM, CE, C-TICK) with
K
WHG approval
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
Selection and Ordering data
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
C
D
E
F
G
H
J
K
L
M
1)
N
C) Subject to export regulations AL: N, ECCN: EAR99
P
Selection and Ordering data
Available with Approvals options F to H and K only
Order code
Further designs
Q
Please add "-Z" to Order No. and specify Order
code(s).
R
S
0
1
2
3
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
0
1
0
1
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
Siemens FI 01 · 2012
5/23
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Standard
5
Selection and Ordering data
Order No.
Selection and Ordering data
Pointek CLS200 - Standard - PFA Coated Rod C)
with PFA Coated Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces
Process connection
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard lengths
Compact (Threaded 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
7ML56347 7 7 77 - 777 0
Pointek CLS200 - Standard - PFA Coated Rod C) 7ML5634with PFA Coated Flanged process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional rod/cable choices and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces
Thermal isolator
Without thermal isolator
0
With thermal isolator [for process connection
1
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
2
With 5 m (197 inch) of cable
3
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 200 ... 1000 mm (7.87 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
5/24
Siemens FI 01 · 2012
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
Order No.
Wetted seals
FKM
FFKM [for process temperatures above
-20°C (-4°F)]
Probe material
PFA Coated 316L Stainless Steel with
PPS probe body
PFA Coated 316L Stainless Steel with
PVDF probe body
Approvals
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
0
1
0
1
F
G
H
A
B
C
D
C) Subject to export regulations AL: N, ECCN: EAR99
Selection and Ordering data
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
■ Overview
■ Configuration
Installation
Pointek CLS200 (digital version) is a versatile inverse frequency
shift capacitance level switch with optional rod/cable choices
and configurable output, ideal for detection of liquids, solids,
slurries, foam, and interfaces. The digital version includes
PROFIBUS PA, an LCD display, and advanced diagnostic
features.
Keep unit out of path of falling material, or protect probe from
falling material.
5
■ Benefits
• Potted construction protects signal circuit from shock,
vibration, humidity and/or condensation
• High chemical resistance
• Level detection independent of tank or pipe earth reference
• Insensitive to product buildup due to high frequency oscillation
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)
Avoid areas where material build up occurs.
■ Application
in
.5
0
)
(2
The power supply is galvanically isolated and accepts a wide
range of voltages (12 to 30 V DC). When used with thermal isolator, the stainless steel and PPS (PVDF optional) materials used
in the probe construction provide a temperature rating up to
+125 °C (+257 °F) on the process wetted portion of the probe.
The switch responds to any material with a dielectric constant of
1.5 or more by detecting a change in oscillating frequency, and
it can be set to detect before contact or on contact with the
probe. The menu-driven setup allows precise control of the
switch point signal damping and alarm functions.
m
Pointek CLS200 digital version provides an integral LCD display
for stand-alone use, and also provides PROFIBUS PA communication (Profile version 3.0, Class B) for connection to a network.
Install probe at least 50 (2) from tank wall.
Pointek CLS200 installation, dimensions in mm (inch)
When connected to the PROFIBUS network, advanced diagnostics and set up using SIMATIC PDM are possible.
The CLS200 operates independently of the tank wall or pipe
so it does not require an external reference electrode for level
detection in a non-conductive vessel such as concrete or plastic
(EMC regulations applicable in some regions).
• Key Applications: liquids, slurries, powders, granules,
pressurized applications, hazardous areas
Siemens FI 01 · 2012
5/25
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
■ Technical specifications
Mode of operation
Measuring principle
Power supply
Inverse frequency shift capacitive level detection
Input
Measured variable
Change in picoFarad (pF)
Bus voltage
Standard: 12 ... 30 V DC
Intrinsically Safe: 12 ... 24 V DC
Current consumption
12.5 mA
Certificates and approvals
Output
General Purpose
CSA, FM, CE, C-TICK
Output signal
• Solid-state output
Dust Ignition Proof
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Flameproof Enclosure with IS Probe
ATEX II 1/2 G EEx d[ia] IIC T6...T4
ATEX II 1/2 D T100 °C
Explosion Proof with IS Probe
CSA/FM Class I,
Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe4)
ATEX II 1 G EEx ia IIC T6 ... T4
ATEX II 1/2 D IP6X T100 °C
CSA/FM Class I, Div. 1, Gr. A, B,
C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Non-incendive
CSA/FM Class I, Div. 2, Gr. A, B,
C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Non-Sparking
ATEX II 3 G Ex nA II T6...T4
ATEX II 2 D IP6X T100 °C
Marine
Lloyds Register of Shipping,
Categories ENV1, ENV2 and
ENV5
Others
Pattern Approval (China)
Communication
PROFIBUS PA
(IEC 61158 CPF3 CP3/2)
Bus physical layer:
IEC 61158-2 MBP (IS)
Device profile:
PROFIBUS PA profile for Process
Control Devices Version 3.0,
Class B
FISCO field device
- Output
- Protection
- Max. switching voltage
- Max. load current
- Voltage drop
- Time delay (ON and/or OFF)
• Fail-safe mode
• Connection
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
Programmable by user
(0 to 100 s)
Min. or max
Removable terminal block
Rated operating conditions1)
5
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +85 °C (-40 ... +185 °F)2)
II
4
Medium conditions
• Relative dielectric constant εr
• Process temperature
- Without thermal isolator
- With thermal isolator
• Process pressure (rod version)
• Process pressure (cable version)3)
• Process pressure
(sliding coupling version)
Liquids, bulk solids, slurries and
interfaces
Min. 1.5
-40 ... +85 °C
(-40 ... +185 °F) 2)
-40 ... +125 °C
(-40 ... +257 °F)
-1 ... +25 bar g
(-14.6 ... +365 psi g) (nominal)
-1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
-1 ... +10 bar g
(-14.6 ... +150 psi g) (nominal)
1)
Design
• Material
• Enclosure
• Optional thermal isolator
Epoxy-coated aluminum with
gasket
316L stainless steel
Connection
Removable terminal block,
max. 2.5 mm²
Degree of protection
IP65/Type 4/NEMA 4
(optional IP68)
Cable inlet
2 x M20x1.5 thread (option:
2 x ½" NPT conduit entry
including 1 plugged entry)
Electromagnetic Compatibility
To comply with CE EMC regulations (where applicable);
the CLS200 should be installed
per the instruction manual.
5/26
Siemens FI 01 · 2012
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 5/35.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F).
3) Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves on page 5/35.
4)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
Design: Probe
Rod version
Sanitary version
Cable version
Sliding Coupling version
Max. length
5500 mm (216.53 inch)
5500 mm (216.53 inch)
30000 mm (1181.1 inch)
liquids and slurries
5000 mm (196.85 inch)
solids (under loads)
5500 mm (216.53 inch)
Process
connection
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
316L stainless steel
ASME/EN flange
1½", 2" sanitary fitting
clamp
316L stainless steel
R ¾", 1", 1¼", 1½"
[(BSPT), EN 10226/PT
(JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
316L stainless steel
ASME/EN flange
R ¾", 1", 1¼", 1½" [(BSPT),
EN 10226/PT (JIS-T),
JIS B 0203]
¾", 1", 1¼", 1½" NPT
[(Taper), ANSI/ASME
B1.20.1]
G ¾", 1", 1½"
[(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
Extension material
316L stainless steel
optional PFA coated1)
316L stainless steel
Fluoroethylene propylene
(FEP) cable with stainless
steel core
316L stainless steel
Sensor wetted parts
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
PPS (optional PVDF)
O-ring seal material
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
FKM (optional FFKM)2)
Thermal isolator3)
Optional
Optional
Optional
Optional
Extension
User selected length
User selected length
Cable extension
User selected length
1)
PFA coating (7ML5634 and 7ML5644) has 120 micron thickness
For Caustic Materials, please contact [email protected] for alternative O-Rings
3) Thermal isolator is used if process connection temperature exceeds +85 °C (+185 °F).
2)
■ Options
process
connection
R 1" (BSPT)
70 (2.75)
32
(1.26)
91 (3.6)
process
connection
¾" NPT
70 (2.75)
91 (3.6)
32
(1.26)
Optional Sensguard
internal thread ¾" NPT
Optional Sensguard, dimensions in mm (inch)
Siemens FI 01 · 2012
5/27
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
5
Selection and Ordering data
L)
Pointek CLS200 - Digital - Rod
with Threaded or Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard lengths
Compact [threaded 120 mm (4.72 inch),
Flanged 98 mm (3.86 inch)]
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
Order No.
7ML56407 7 7 77 - 777 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
A
B
C
D
E
F
G
H
J
K
L
Selection and Ordering data
Order No.
L) 7ML5640Pointek CLS200 - Digital - Rod
with Threaded or Flanged process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 210 ... 1000 mm (8.27 ... 39.37 inch)
M
Extended rod, 1001 ... 2000 mm
N
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
P
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
Q
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
R
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
S
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
0
With thermal isolator [for process connection
1
temperatures over +85 °C (+185 °F)]
Remote mount electronics and mounting
bracket
With 2 m (79 inch) of cable
2
With 5 m (197 inch) of cable
3
Wetted seals
FKM
0
FFKM [for process temperatures above
1
-20 °C (-4 °F)]
Probe material
316L Stainless Steel with PPS probe body
0
316L Stainless Steel with PVDF probe body
1
Approvals
Non-Sparking:
B
CE, C-TICK, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
C
CE, C-TICK, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
D
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
E
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive:
F
CSA/FM Class I, Div. 2, Gr. A, B, C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
G
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
J
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
K
General Purpose (CE, C-TICK)
L
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
L) Subject to export regulations AL: N, ECCN: 3A991X.
5/28
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
Selection and Ordering data
Order No.
Pointek CLS200 - Digital - Cable with Threaded C)
or Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5 or EN 1092-1 standard.)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard lengths
Extended cable, 3000 mm (118.11 inch), length
can be determined by customer on assembly
Extended cable, 6000 mm (236.22 inch), length
can be determinded by customer on assembly
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 5000 mm
(19.69 ... 196.85 inch)
Extended cable, 5001 ... 10000 mm
(196.89 ... 393.70 inch)
Extended cable, 10001 ... 15000 mm
(393.74 ... 590.55 inch)
Extended cable, 15001 ... 20000 mm
(590.59 ... 787.4 inch)
Extended cable, 20001 ... 25000 mm
(787.44 ... 984.25 inch)
Extended cable, 25001 ... 30000 mm
(984.29 ... 1181.1 inch)
7ML564177 7 77 - 777 0
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
5
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
A
B
C
D
E
F
G
H
Siemens FI 01 · 2012
5/29
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
Order No.
Pointek CLS200 - Digital - Cable with Threaded C) 7ML5641or Flanged process connection
7 7 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Thermal isolator
Without thermal isolator
0
With thermal isolator [for process connection
1
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
2
With 5 m (197 inch) of cable
3
Wetted seals
FKM and PTFE
0
FFKM and PTFE [for process temperatures
1
above -20 °C (-4 °F)]
Probe material
FEP jacketed cable with PPS probe body
0
FEP jacketed cable with PVDF probe body
1
Approvals
Non-Sparking:
B
CE, C-TICK, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
C
CE, C-TICK, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
D
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
E
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Non-incendive:
F
CSA/FM Class I, Div. 2, Gr. A, B, C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
G
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
J
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
K
General Purpose (CE, C-TICK)
L
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
Selection and Ordering data
5
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
C) Subject to export regulations AL: N, ECCN: EAR99.
5/30
Siemens FI 01 · 2012
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Order No.
C) 7ML5642Pointek CLS200 - Digital - Rod with Sanitary
process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Selection and Ordering data
Process connection
Sanitary 316L stainless steel
Non-incendive:
CSA/FM Class I, Div. 2, Gr. A, B, C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
F
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
Intrinsically Safe:1)
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
H
Explosion Proof with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
J
General Purpose (CSA, FM)
K
General Purpose (CE, C-TICK)
L
1" sanitary fitting clamp
1½" sanitary fitting clamp
2" sanitary fitting clamp
8A
8B
8C
2½" sanitary fitting clamp
3" sanitary fitting clamp
(Note: Sanitary connection dimensionally corresponds to the applicable ISO 2852 standard)
8D
8E
Probe length (length from process connection face)
Note: No Y01 needed in order code for
standard lengths
Compact 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
A
B
C
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
D
E
F
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
G
H
J
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
K
L
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 110 ... 350 mm (4.3 ... 13.78 inch)
Extended rod, 351 ... 1000 mm
(13.82 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Order No.
C) 7ML5642Pointek CLS200 - Digital - Rod with Sanitary
process connection
7 7 7 77 - 77 7 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
5
Enclosure and lid
Aluminum epoxy coated
A
B
C
D
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
1)
M
N
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
C) Subject to export regulations AL: N, ECCN: EAR99.
Order code
Selection and Ordering data
P
Further designs
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Q
Please add "-Z" to Order No. and specify Order
code(s).
R
Total insertion length: enter the total insertion length
in plain text description
Y01
T
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
With 5 m (197 inch) of cable
Wetted seals
FKM
FFKM [for process temperatures above -20 °C (-4°F)]
S
0
1
Operating Instructions
2
3
0
1
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
Probe material
316L Stainless Steel with PPS probe body
316L Stainless Steel with PVDF probe body
Approvals
Non-Sparking:
CE, C-TICK, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
0
1
B
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D T100 °C
C
Intrinsically Safe:1)
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
D
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
E
Siemens FI 01 · 2012
5/31
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
5
Selection and Ordering data
Order No.
C)
Pointek CLS200 - Digital - Rod with Sliding
coupling with Threaded process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard
lengths
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 350 ... 1000 mm
(13.82 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
With 5 m (197 inch) of cable
Wetted seals
FKM and PTFE
FFKM and PTFE [for process temperatures above
-20°C (-4°F)]
Probe material
316L Stainless Steel with PPS probe body
316L Stainless Steel with PVDF probe body
Approvals
Non-Sparking:
CE, C-TICK, ATEX II 3 G Ex nA II T6...T4,
ATEX II 2 D IP6X T100 °C
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D T100 °C
Intrinsically Safe:1)
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
7ML563437 7 7 77 - 777 0
5/32
Siemens FI 01 · 2012
Order No.
C) 7ML56343Pointek CLS200 - Digital - Rod with Sliding
coupling with Threaded process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Non-incendive:
F
CSA/FM Class I, Div. 2, Gr. A, B, C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
G
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
J
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
K
General Purpose (CE, C-TICK)
L
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
Selection and Ordering data
0A
0B
0C
0D
1A
1B
1D
3A
3B
3D
C
D
E
F
G
H
J
K
L
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
C) Subject to export regulations AL: N, ECCN: EAR99.
Selection and Ordering data
M
Further designs
N
Please add "-Z" to Order No. and specify Order
code(s).
Order code
P
Total insertion length: enter the total insertion length
in plain text description
Y01
Q
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
R
S
0
1
Operating Instructions
2
3
0
1
0
1
B
C
D
E
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/34
Accessories
See page 5/34
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 – Digital
Selection and Ordering data
Order No.
C)
Pointek CLS200 - Digital - PFA Rod with PFA
Flanged process connection
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Process connection
Welded flange, PFA coated, 316L stainless steel,
raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, PFA coated, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Probe length (length from process connection
face)
Note: No Y01 needed in order code for
standard lengths
Compact (Threaded 98 mm (3.86 inch)
Extended rod, 250 mm (9.84 inch)
Extended rod, 350 mm (13.78 inch)
Extended rod, 500 mm (19.69 inch)
Extended rod, 750 mm (29.53 inch)
Extended rod, 1000 mm (39.37 inch)
Extended rod, 1250 mm (49.21 inch)
Extended rod, 1350 mm (53.15 inch)
Extended rod, 1500 mm (59.06 inch)
Extended rod, 1750 mm (68.90 inch)
Extended rod, 2000 mm (78.74 inch)
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, 200 ... 1000 mm (7.87 ... 39.33 inch)
Extended rod, 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Extended rod, 2001 ... 3000 mm
(78.78 ... 118.11 inch)
Extended rod, 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Extended rod, 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Extended rod, 5001 ... 5500 mm
(196.89 ... 216.53 inch)
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Remote mount electronics and
mounting bracket
With 2 m (79 inch) of cable
With 5 m (197 inch) of cable
7ML56447 7 7 77 - 777 0
5A
5B
5C
5D
5E
5F
5G
5H
5J
5K
5L
5M
5N
5P
5Q
6A
6B
6C
6D
6E
6F
6G
6H
6J
6K
Order No.
C) 7ML5644Pointek CLS200 - Digital - PFA Rod with PFA
Flanged process connection
77 7 77 - 777 0
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Wetted seals
FKM
0
FFKM [for process temperatures above
1
-20°C (-4°F)]
Probe material
PFA Coated 316L Stainless Steel with PPS probe
0
body
PFA Coated 316L Stainless Steel with PVDF probe
1
body
Approvals
Non-incendive:
F
CSA/FM Class I, Div. 2, Gr. A, B, C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Dust Ignition Proof with IS Probe:
G
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe:1)
H
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof with IS Probe:
J
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
K
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
A
2 x M20x1.5 cable inlet, IP65
B
2 x ½" NPT via adapter - cable inlet, IP68
C
2 x M20x1.5 cable inlet, IP68
D
Selection and Ordering data
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
pro-tection
C) Subject to export regulations AL: N, ECCN: EAR99.
A
B
C
D
E
F
G
H
J
K
L
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
M
N
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
R
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
S
Accessories
P
Q
See page 5/34
See page 5/34
0
1
2
3
Siemens FI 01 · 2012
5/33
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
Selection and Ordering data
Order code
Operating Instructions - Standard
English
C) 7ML1998-5JH03
C) 7ML1998-5JH32
German
Note: The Operating Instructions should be ordered as a separate line on the order.
Quick Start manual, multi-language
C) 7ML1998-5QY82
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Operating Instructions - Digital
English
C) 7ML1998-5JJ03
C) 7ML1998-5JJ34
German
Note: The Operating Instructions should be ordered as a separate line on the order.
Quick Start manual, multi-language
C) 7ML1998-5XA83
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
5
Sensguard, ¾" NPT (PPS)
Only available for CLS200 with ¾" NPT thread
7ML1830-1DL
Sensguard, R 1" (BSPT) (PPS)
Only available for CLS200 with ¾" NPT thread
7ML1830-1DM
One metallic cable gland M20x1.5, -40 ... +80 °C
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
7ML1930-1AQ
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K C) A5E03252530
NEMA6, -40 ... -100 °C (-40 ... -212 °F),
cable size 6 ... 12 mm (0.236 ... 0.472 inch)
M20x1.5 General Purpose Cable Entry IP68/IP69K C) A5E03252531
NEMA6,-40 ... -100 °C (-40 ... -212 °F),
cable size
7 ... 12 mm (0.275 ... 0.472 inch)
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition
Proof, Flameproof Exd, and Increased Safety ATEX
II 2 GD ExtD A21 (Zone 1,Zone 2, Zone 21,
Zone 22, and in Gas Groups IIA,IIB and IIC)
-60 ... +80 °C IP66,IP67,IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
A5E03252527
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2
GD ExtD A21 (Zone 1, Zone 2, Zone 21, Zone 22
and in Gas Groups IIA,IIB and IIC)
-60 ... +80 °C IP66,IP67,IP68, NEMA4X,
cable sizes 5.5 ... 12 mm (0.216 ... 0.472 inch)
A5E03252528
Blind threaded flanges are available.
Please contact [email protected] with a
completed application data sheet on page 5/9
Pointek Specials
5/34
Siemens FI 01 · 2012
See page 5/79
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
■ Characteristic curves
Pressure/Temperature Curve
CLS200 Sliding Coupling
Threaded Process Connections
(7ML5633 and 7ML5643)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
300 ºF
(149 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
5
Permitted Operating Temperature T
Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5633 and 7ML5643)
Pressure/Temperature Curve
CLS200 Cable
Threaded Process Connections
(7ML5631 and 7ML5641)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted Operating Temperature T
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Siemens FI 01 · 2012
5/35
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
Pressure/Temperature Curve
CLS200 Compact and Extended Rod
Threaded Process Connections
(7ML5630 and 7ML5640)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
5
100 ºF
(38 ºC)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted Operating Temperature T
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 or 7ML5640)
Pressure/Temperature Curve
CLS200 Compact and Extended Sanitary Type
Sanitary Process Connections
(7ML5632 and 7ML5642)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5632 and 7ML5642)
5/36
Siemens FI 01 · 2012
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
Pressure/Temperature Curve
CLS200 Cable
ASME Flanged Process Connections
(7ML5631 and 7ML5641)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
ASME 150 lb1)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
5
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Pressure/Temperature Curve
CLS200 Compact and Extended Rod
ASME Flanged Process Connections
(7ML5630 and 7ML5640)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)
Siemens FI 01 · 2012
5/37
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
Pressure/Temperature Curve
CLS200 Cable
EN Flanged Process Connections
(7ML5631 and 7ML5641)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
PN 161)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
5
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5631 and 7ML5641)
Pressure/Temperature Curve
CLS200 Compact and Extended Rod
EN Flanged Process Connections
(7ML5630 and 7ML5640)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS200 Process Pressure/Temperature derating curves (7ML5630 and 7ML5640)
5/38
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
■ Dimensional drawings
Compact version
Threaded
(7ML5630 and 7ML5640)
Extended cable version
Threaded
(7ML5631 and 7ML5641)
Extended rod version
Threaded
(7ML5630 and 7ML5640)
Y01 (insertion length)
Sanitary compact version
Sanitary fitting
(7ML5632 and 7ML5642)
316L stainless
steel extension
Y01 (insertion length)
PPS or optional
PVDF probe
Ø20 (0.79)
84
(3.3)
22
(0.87)
PPS or optional
PVDF probe
Min. insertion length = 200 (7.87)
Max. insertion length = 5500 (216)
98
(3.8)
84
(3.3)
5
PPS or optional
PVDF probe
Min. insertion length = 500 (19.69)
Max. insertion length = 30000 (1181)
Applicable for liquids and solids
applications. Cable can be shortened
on site.
PPS or optional
PVDF probe
Sanitary extended version
Sanitary fitting
(7ML5632 and 7ML5642)
Sliding coupling version
Threaded
(7ML5633 and 7ML5643)
316L stainless
steel sliding
coupling
Ø24 (0.95)
PPS or optional
PVDF probe
Min. insertion length = 110 (4.3)
Max. insertion length = 5500 (216)
Y01 (insertion length)
316L stainless
steel extension
98
(3.8)
252 (9.92)
316L stainless steel
sanitary process
connection
Ø20 (0.79)
84
(3.3)
thermal
isolator
239 (9.41)
151
(5.94)
lid without window
Y01 (insertion length)
M20: 135 (5.32)
½" NPT: 150 (5.91)
lid with window
164 (6.46)
316L stainless steel
sensor weight
Ø20 (0.79)
316L stainless steel
sanitary process
connection
2 cable entries
½" NPT or
M20 x 1.5
FEP insulated
cable Ø6 (0.3)
min. 215
(8.46)
120
(4.7)
electronics/
enclosure
PPS or optional
PVDF probe
Min. insertion length = 350 (13.82)
Max. insertion length = 5500 (216)
Pointek CLS200 dimensions - Threaded/Sanitary Process connections, dimensions in mm (inch)
Siemens FI 01 · 2012
5/39
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
Compact version
Welded Flange (7ML5630 and 7ML5640)
Welded Flange, PFA coated
(7ML5634 and 7ML5644)
Extended rod version
Welded Flange (7ML5630 and 7ML5640)
Welded Flange, PFA coated
(7ML5634 and 7ML5644)
Extended cable version
Welded Flange
(7ML5631 and 7ML5641)
2 cable entries
½" NPT or
M20 x 1.5
Ø20 (0.79)
PPS or optional
PVDF probe
Min. insertion length = 200 (7.87)
Max. insertion length = 5500 (216)
lid with window
164 (6.46)
5
239 (9.41)
252 (9.92)
151
(5.94)
316L stainless steel
sensor weight
Ø20 (0.79)
PPS or optional
PVDF probe
Min. insertion length = 500 (19.69)
Max. insertion length = 30000 (1181)
Applicable for liquids and solids applications. Cable can be shortened on site.
lid without window
thermal
isolator
FEP insulated
cable Ø6 (0.3)
84
(3.3)
M20: 135 (5.32)
½" NPT: 150 (5.91)
316L stainless
steel extension
(or PFA coated
Y01 (insertion length)
PPS or optional
PVDF probe
84
(3.3)
Y01 (insertion length)
98
(3.8)
electronics/
enclosure
Flange Facing (raised face)
Flange Class
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
Insertion length does not include any raised face/gasket face dimension
(see Flange Facing Table above)
Pointek CLS200 dimensions - Flanged Process connections, dimensions in mm (inch)
5/40
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS200 - Standard and Digital
■ Schematics
Wiring: Pointek CLS200 Standard
white
black
red
P2
(f )
(+)
switch bank
trip
point
S1
P1
K1
OFF
GND
3
+
delay
2
1
K4
sensor
L1
L2
L3
sensor
status
power
on
1
2
3
power
supply
12 to 250 V AC/DC
output
status
NC
NO
NO
K2
K3
solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
relay contact:
8 A at 250 V AC, 2000 VA
5 A at 30 V DC, 150 W
5
Notes:
- Identification label is on underside of lid. Switch and Potentiometer settings
are for illustration purposes only (Refer to Operation/Setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.
Wiring: Pointek CLS200 Digital
white
test input
reed
contact*
white
red (+)
black (-)
sensor
alarm output
solid-state switch
orange (f)
24 V DC/PROFIBUS PA
power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the Instruction Manual or contact a Siemens representative
for detailed wiring information.
*Magnet Activated Sensor Test
A magnet can be used to test the sensor without opening the lid of the
Pointek CLS200 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.
Pointek CLS200 connections
Siemens FI 01 · 2012
5/41
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
■ Overview
■ Configuration
Installation
5
Pointek CLS300 (standard version) is an inverse frequency shift
capacitance level switch with optional rod/cable choices and
configurable output. It is ideal for detecting liquids, solids,
slurries, foam, and interfaces in demanding conditions where
high pressure and temperatures are present.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Patented Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active
shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Three LED indicators for adjustment control, output status and
power
• High-temperature version up to +400 °C (+185 °F)
Build up of material in active shield area does not affect
switch operation.
■ Application
.5
0
)
(2
Siemens FI 01 · 2012
in
5/42
m
Pointek CLS300 standard version has three LED indicators with
basic relay and solid-state switch alarms.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
The fully potted electronics are unaffected by condensation,
dust or vibration.
Wetted parts are made of stainless steel with a PFA shield for
high chemical resistance, and of ceramic and stainless steel for
high temperature version. Materials with low or high dielectric
constants can be accurately detected. The unique Active Shield
suppresses interference from material buildup or long installation nozzles.
The unique modular design of the Pointek CLS300 provides a
wide range of configurations, process connections, extensions
and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range
of probe configurations are available, including rod and cable
versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and mining applications
min.
50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
Pointek CLS300 installation, dimensions in mm (inch)
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
■ Technical specifications
Mode of operation
Measuring principle
Design
Inverse frequency shift capacitive level detection
Input
Measured variable
Material (enclosure)
Powder-coated aluminum with
gasket
Degree of Protection
Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68
Cable inlet
2 x M20x1.5 thread
(option: 2 x ½" NPT conduit entry
including 1 plugged entry)
Change in picoFarad (pF)
Output
Output signal
1 SPDT Form C relay
Controls and displays
- Max. contact voltage
• 30 V DC
• 250 V AC
Displays
3 LEDs, for probe status, output
status and power supply
- Max. contact current
• 5 A (DC)
• 8 A (AC)
Potentiometers
2 potentiometers for time delay
and sensitivity
Switches
- Max. switching capacity
• 150 W (DC)
• 2000 VA (AC)
5 DIP switches for delay on/off,
fail-safe high/low, time delay
test/adjust, high/low sensitivity,
test delay settings
- Time delay (ON and/or OFF)
1 ... 60 s
• Relay output
• Solid-state output
Power supply
Supply
12 ... 250 V AC/DC, 0 ... 60 Hz,
galvanically isolated, 2 W
- Output
Galvanically isolated
- Protection
Against reversed polarity (bipolar)
Certificates and approvals
- Max. switching voltage
• 30 V (DC)
• 30 V peak (AC)
General Purpose
CSA, FM, CE, C-TICK
Flameproof Enclosure with IS Probe
- Max. load current
82 mA
ATEX II 1/2 G EEx d[ia] IIC T6...T1
ATEX II 1/2 D T100 °C
- Voltage drop
< 1 V, typical at 50 mA
Dust Ignition Proof with IS Probe
- Time delay
(pre or post switching)
1 ... 60 s
ATEX II 1/2 D T100 °C
CSA/FM Class II, Div. 1,
Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS
Probe
CSA/FM Class I, Div. 1,
Gr. A, B, C, D
CSA/FM Class II, Div. 1,
Gr. E, F, G
CSA/FM Class III T4
Marine
Lloyds Register of
Shipping, Categories ENV1,
ENV2 and ENV5
Overfill Protection
WHG (Germany)
VLAREM II (Belgium)
Others
Pattern Approval (China)
Accuracy
Resolution
• Min. sensitivity (pF)
1 % change in actual capacitance
• Max. temperature error
0.2 % of actual capacitance value
Rated operating conditions1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +85 °C (-40 ... +185 °F)2)
Medium conditions
Liquids, bulk solids, slurries and
interfaces, and applications with
viscous materials
• Relative dielectric constant εr
Min. 1.5
• Process temperature
- Rod/Cable version
-40 ... +200 °C (-40 ... +392 °F)2)
- High-temperature version
-40 ... +400 °C (-40 ... +752 °F)
• Process pressure3)
5
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves starting on page 5/58.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F).
3) Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 5/58.
-1 ... +35 bar g
(-14.6 ... +511 psi g)
Siemens FI 01 · 2012
5/43
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Design: Probe
Rod version
High Temperature version
Cable version
Length
Min. 250 mm (9.8 inch),
max. 1000 mm (40 inch)
Min. 250 mm (9.8 inch),
max. 1000 mm (40 inch)
Min. 1000 mm (40 inch),
max. 25000 mm (984 inch)
Sensor wetted parts
PFA (no insulation on active
probe), 316L stainless steel,
PEEK isolators
Ceramic (ZrO21)) isolators
(no insulation on active probe),
316L stainless steel
316 stainless steel, optional PFA,
PEEK isolators
O-ring seal material
FKM (optional FFKM)2)
Graphite2)
FKM (optional FFKM)2)
Thermal isolator
Optional
Standard
Optional
Extension
User selectable length
User selectable length
User selectable cable length
1)
2)
Zirconium Oxide
For Caustic Materials, please contact [email protected] for alternative O-rings.
5
5/44
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Order No.
Order No.
Selection and Ordering data
C) 7ML5650Pointek CLS300 - Standard - Rod Version
with Threaded or Flanged process connection
77 7 77 - 0 77 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids,
slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are
present.
C) 7ML5650Pointek CLS300 - Standard - Rod Version
with Threaded or Flanged process connection
77 7 77 - 0 77 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids,
slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are
present.
Process connection
Threaded, 316L stainless steel
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
0A
0B
0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
0D
1A
1B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1D
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
3A
3B
3D
5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat
faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
6A
6B
6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
6G
6H
6J
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5
or EN 1092-1 standard.)
6K
G
Wetted seals
FKM
FFKM [for process temperatures above
-20°C (-4°F)]
0
1
0
1
Probe material
316L stainless steel with PFA lining and PEEK
isolators
5
0
Approvals
Dust Ignition Proof with IS Probe:
CE, C-TICK, ATEX II 1/2 D T100 °C
C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
D
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
General Purpose (CSA, FM)
H
A
B
C
D
E
General Purpose (CE, C-TICK)
J
General Purpose with WHG approval
(CSA, FM, CE, C-TICK)
K
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard
lengths
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1000 mm (39.37 inch)
F
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
E
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)2)
A
B
C
D
0
1
2
1)
Available with Probe version options B to D, F, G only [≥ 500 mm
(19.69 inch)]
2)
Available with Probe version options C, D, and, G only [≥ 750 mm
(29.53 inch)]
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/45
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Order No.
C) 7ML5651Pointek CLS300 - Standard - Cable Version
with Threaded or Flanged process connection
77 7 77 - 777 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Process connection
Threaded, 316L stainless steel
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
Accessories
See page 5/57
5
Selection and Ordering data
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
0C
0D
1D
3D
Welded flange, 316L stainless steel, raised face
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
Welded flange, 316L stainless steel,
Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
6C
6D
6E
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
6J
6K
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for
standard lengths
Extended cable, 3000 mm (118.11 inch),
length can be shortened by customer
Extended cable, 6000 mm (236.22 inch),
length can be shortened by customer
A
B
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 1000 mm
(19.69 ... 39.37 inch)
E
Extended cable, 1001 ... 5000 mm
(39.41 ... 196.85 inch)
F
Extended cable, 5001 ... 10000 mm
(196.89 ... 393.70 inch)
G
Extended cable, 10001 ... 15000 mm
(393.74 ... 590.55 inch)
Extended cable, 15001 ... 20000 mm
(590.59 ... 787.40 inch)
H
Extended cable, 20001 ... 25000 mm
(787.44 ... 984.25 inch)
K
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
5/46
Siemens FI 01 · 2012
J
0
1
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Wetted seals
FKM
FFKM [for process temperatures above
-20°C (-4°F)]
0
1
Probe material
Bare 316L stainless steel cable, PEEK isolators and
316L stainless steel cable weight
PFA coated cable, PEEK isolators and 316L
stainless steel cable weight
Order code
Selection and Ordering data
Order No.
C) 7ML5651Pointek CLS300 - Standard - Cable Version
with Threaded or Flanged process connection
7 7 7 77 - 777 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
0
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
1
Approvals
Dust Ignition Proof with IS Probe:
CE, C-TICK, ATEX II 1/2 D T100 °C
C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
D
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
General Purpose (CSA, FM)
H
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
Accessories
See page 5/57
E
General Purpose (CE, C-TICK)
J
General Purpose with WHG approval
(CSA, FM, CE, C-TICK)
K
5
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)1)
1)
A
B
C
D
0
1
2
Available with Probe version options A, B, F to K, only [≥ 1000 mm
(39.7 inch)]
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/47
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Selection and Ordering data
Order No.
Pointek CLS300 - Standard - High Temperature C) 7ML5652Rod Version with Threaded or Flanged process
7 7 7 00 0 - 0 7 7 7
connection
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Process connection
Threaded, 316L stainless steel
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
0A
0B
0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
0D
1A
1B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
1D
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
5
Order No.
Pointek CLS300 - Standard - High Temperature C) 7ML5652Rod Version with Threaded or Flanged process
7 7 7 00 0 - 0 7 7 7
connection
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Wetted seals
Graphite
3A
3B
Probe material
316L stainless steel with ceramic (ZrO2) isolators
3D
Approvals
Welded flange, 316L stainless steel, raised face
E
F
G
0
0
Dust Ignition Proof with IS Probe:
CE, C-TICK, ATEX II 1/2 D T100 °C
C
D
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Flameproof Enclosure with IS Probe, with WHG
approval:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
General Purpose (CSA, FM)
H
Welded flange, 316L stainless steel, Type A flat
faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
6A
6B
6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
6G
6H
6J
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
6K
Rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1000 mm (39.37 inch)
5/48
Siemens FI 01 · 2012
General Purpose (CE, C-TICK)
J
General Purpose with WHG approval
(CSA, FM, CE, C-TICK)
K
Enclosure and lid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
A
B
C
2 x M20x1.5 cable inlet, IP68
D
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)1)
Extended shield (400 mm threaded, 380 mm flanged)2)
1)
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
2)
Available with Probe version options B to D, F, G only [≥ 500 mm
(19.69 inch)]
Available with Probe version options C, D, and, G only [≥ 750 mm
(29.53 inch)]
C) Subject to export regulations AL: N, ECCN: EAR99H.
A
B
C
D
E
0
1
2
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
Accessories
See page 5/57
5
Siemens FI 01 · 2012
5/49
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
■ Overview
■ Application
Pointek CLS300 digital version provides an integral LCD display
for stand-alone use, with PROFIBUS PA communication
(Profile version 3.0, Class B) when required. Solid-state switch
alarm is standard.
The robust design of CLS300 makes it specifically applicable for
heavy solids applications where abrasive materials occur as in
the mining industry.
The fully potted electronics are unaffected by condensation,
dust or vibration.
5
Pointek CLS300 (digital version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries,
foam, and interfaces in demanding conditions where high pressure and temperatures are present. The digital version includes
PROFIBUS PA, an LCD display, and advanced diagnostic features.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup or nozzle interference in active
shield section
• Performs in extremely abrasive conditions because of solid
rod construction
• Push-button calibration, full-function diagnostics
• High sensitivity allows installation in a wide range of liquids,
solids or slurry applications
• Integral LCD display allows for easy menu-driven setup
• PROFIBUS PA communication (SIMATIC PDM compatible)
5/50
Siemens FI 01 · 2012
Wetted parts are made of stainless steel with a PFA shield for
high chemical resistance, and of ceramic and stainless steel for
high temperature version. Materials with low or high dielectric
constants can be accurately detected. The unique Active Shield
suppresses interference from material buildup or long installation nozzles.108The unique modular design of the Pointek
CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and
pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements.
A wide range of probe configurations are available, including
rod and cable versions.
• Key Applications: liquids, slurries, bulk solids, relatively high
pressure and temperature, hazardous areas, milling and mining applications
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
■ Configuration
Installation
Keep unit out of path of falling material, or protect probe from
falling material.
5
Build up of material in active shield area does not affect
switch operation.
m
in
.5
0
)
(2
min.
50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
Pointek CLS300 installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/51
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
■ Technical specifications
Controls and displays
Mode of operation
Measuring principle
Inverse frequency shift capacitive level detection
Local display
LCD
Configuration
• Locally, using 3 button keypad
(for standalone operation)
• Remotely, using SIMATIC PDM
(for installation on a network)
Input
Measured variable
Change in picoFarad (pF)
Output
Power supply
Solid-state output
• Output
• Protection
• Max. switching voltage
• Max. load current
• Voltage drop
• Time delay (pre or post switching)
Galvanically isolated
Against reversed polarity (bipolar)
• 30 V (DC)
• 30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
Programmable by user
(0 ... 100 s)
Fail-safe mode
Min. or max.
Connection
Removable terminal block
Bus voltage (at process connection)
• Standard: 12 ... 30 V DC
• Intrinsically Safe: 12 ... 24 V DC
Current consumption
12.5 mA
Certificates and approvals
General Purpose
CSA, FM, CE, C-TICK
Dust Ignition Proof
ATEX II 1/2 D, 2 D IP6X T100 °C
Flameproof Enclosure With IS Probe
ATEX II 1/2 G EEx d[ia] IIC
T6 ...T4
ATEX II 1/2 D T100 °C
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe 4)
ATEX II 1 G EEx ia IIC T6...T4
ATEX II 1/2 D, 2 D IP6X T100 °C
CSA/FM Class I, Div. 1, Gr. A, B,
C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Non-incendive
CSA/FM Class I, Div. 2, Gr. A, B,
C, D
CSA/FM Class II, Div. 2, Gr. F, G
CSA/FM Class III T4 or T6
Explosion Proof with IS Probe
CSA/FM Class I, Div. 1, Gr. A, B,
C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Marine
Lloyds Register of Shipping,
Categories ENV1, ENV2 and
ENV5
Others
Pattern Approval (China)
Communication
PROFIBUS PA
(IEC 61158 CPF3 CP3/2)
Bus physical layer:
IEC 61158-2 MBP-(IS)
Device profile: PROFIBUS PA profile for Process Control Devices
Version 3.0, Class B
FISCO field device
Accuracy
5
Resolution
• Min. sensitivity (pF)
• Max. temperature error
1% change in actual capacitance
0.2% of actual capacitance value
Rated operating conditions1)
Installation conditions
Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +85 °C (-40 ... +185 °F)2)
Medium conditions
• Relative dielectric constant εr
• Process temperature
- Rod/Cable version
- High Temperature version
• Process pressure3)
Liquids, bulk solids, slurries and
interfaces, and applications with
viscous materials
Min. 1.5
-40 ... +200 °C (-40 ... +392 °F)2)
-40 ... +400 °C (-40 ... +752 °F)
-1 ... +35 bar g
(-14.6 ... +511 psi g)
Design
Material (enclosure)
Powder-coated aluminum with
gasket
Degree of protection
Standard: Type 4/NEMA 4/IP65
Optional: Type 4/NEMA 4/IP68
Cable inlet
2 x M20x1.5 thread (option:
2 x ½" NPT conduit entry
including 1 plugged entry)
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves starting on page 5/58.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F)
3)
Pressure rating of process seal is temperature dependent.
See Pressure/Temperature curves starting on page 5/58.
4) Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
Design: Proble
Rod version
High Temperature version
Cable version
Length
Min. 250 mm (9.8 inch),
max. 1000 mm (40 inch)
Min. 250 mm (9.8 inch),
max. 1000 mm (40 inch)
Min. 1000 mm (40 inch),
max. 25000 mm (984 inch)
Sensor wetted parts
PFA (no insulation on active probe),
316L stainless steel, PEEK isolators
Ceramic (ZrO21)) isolators
(no insulation on active probe),
316L stainless steel
316 stainless steel, optional PFA,
PEEK isolators
O-ring seal material
FKM (optional FFKM)2)
Graphite2)
FKM (optional FFKM)2)
Thermal isolator
Optional
Standard
Optional
Extension
User selectable length
User selectable length
User selectable cable length
1)
Zirconium Oxide
2) For Caustic Materials please contact [email protected] for for alternative O-rings
5/52
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Order No.
Order No.
Selection and Ordering data
Pointek CLS300 - Digital - Rod with Threaded or C) 7ML5660Flanged process connection
7 7 7 77 - 0 77 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Pointek CLS300 - Digital - Rod with Threaded or C) 7ML5660Flanged process connection
77 7 77 - 0 77 7
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Process connection
Threaded, 316L stainless steel
Add order code Y01 and plain text:
"Insertion length ... mm"
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
0A
0B
0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
0D
1A
1B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
1D
3A
3B
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
3D
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
5G
5H
2" ASME, 600 lb
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
Welded flange, 316L stainless steel, Type A flat
faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
6A
6B
6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
6G
6H
6J
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
6K
G
0
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Wetted seals
FKM
FFKM [for process temperatures above -20 °C (-4 °F)]
Probe material
316L stainless steel with PFA lining and PEEK
isolators
1
0
1
5
0
Approvals
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 °C
B
Intrinsically Safe1)
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
D
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
E
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
General Purpose (CSA, FM)
H
General Purpose (CSA, FM, CE, C-TICK)
J
Enclosure andlLid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1000 mm (39.37 inch)
F
Thermal isolator
Without thermal isolator
Welded flange, 316L stainless steel, raised face
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
E
A
B
C
D
A
B
C
D
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)3)
0
1
2
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2)
Available with Probe version options B to D, F, G only [≥ 500 mm
(19.69 inch)]
3) Available with Probe version options C, D, and, G only [≥ 750 mm
(29.53 inch) inch)]
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/53
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Process connection
Threaded, 316L stainless steel
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
0C
0D
1D
3D
Welded flange, 316L stainless steel, raised face
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
Accessories
See page 5/57
5
Order No.
Pointek CLS300 - Digital - Cable with Threaded C) 7ML5661or Flanged process connection
77 7 77 - 777 7
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Selection and Ordering data
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
Welded flange, 316L stainless steel, Type A flat
faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
6C
6D
6E
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
6J
6K
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
Extended cable, 3000 mm (118.11 inch),
length can be shortened by customer
Extended cable, 6000 mm (236.22 inch),
length can be shortened by customer
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended cable, 500 ... 1000 mm
(19.69 ... 39.37 inch)
Extended cable, 1001 ... 5000 mm
(39.41 ... 196.85 inch)
Extended cable, 5001 ... 10000 mm
(196.89 ... 393.70 inch)
Extended cable, 10001 ... 15000 mm
(393.74 ... 590.55 inch)
Extended cable, 15001 ... 20000 mm
(590.59 ... 787.40 inch)
Extended cable, 20001 ... 25000 mm
(787.44 ... 984.25 inch)
5/54
Siemens FI 01 · 2012
A
B
E
F
G
H
J
K
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
Order No.
Pointek CLS300 - Digital - Cable with Threaded C) 7ML5661or Flanged process connection
7 7 7 77 - 777 7
Versatile inverse frequency shift capacitance level
switch with optional process connection choices
and configurable output, ideal for detection of
liquids, solids, slurries, foam, and interfaces
Selection and Ordering data
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Wetted seals
FKM
FFKM [for process temperatures above -20 °C (-4 °F)]
Probe material
Bare 316L stainless steel cable, PEEK isolators and
316L stainless steel cable weight
PFA coated cable, PEEK isolators and 316L stainless steel cable weight
0
1
0
1
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
0
1
Approvals
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 °C
B
Intrinsically Safe1)
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
D
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
E
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
F
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
G
General Purpose (CSA, FM)
H
General Purpose (CSA, FM, CE, C-TICK)
J
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
Accessories
See page 5/57
5
Enclosure andlLid
Aluminum epoxy coated
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
A
B
C
D
Active shield length
Standard length (125 mm threaded, 105 mm flanged)
Extended shield 250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)2)
0
1
2
1)
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
2) Available with Probe version options A, B and, F to K only
[≥ 1000 mm (39.7 inch)]
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/55
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Digital
Selection and Ordering data
Order No.
Order No.
C) 7ML5652Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
777 0 0 - 0 777
connection
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
Process connection
Threaded, 316L stainless steel
Probe material
316L stainless steel with ceramic (ZrO2) isolators
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
0A
0B
0C
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
0D
1A
1B
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
1D
3A
3B
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
3D
Approvals
Dust Ignition Proof:
CE, C-TICK, ATEX II 1/2 D, 2 D IP6X T100 °C
Intrinsically Safe1)
CE, C-TICK, ATEX II 1 G EEx ia IIC T6...T4,
ATEX II 1/2 D, 2 D IP6X T100 °C
Flameproof Enclosure with IS Probe:
CE, C-TICK, ATEX II 1/2 G EEx d[ia] IIC T6...T4,
ATEX II 1/2 D T100 °C
Dust Ignition Proof with IS Probe:
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Intrinsically Safe1)
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure with IS Probe:
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
General Purpose (CSA, FM)
General Purpose (CSA, FM, CE, C-TICK)
Welded flange, 316L stainless steel, raised face
5
Selection and Ordering data
C) 7ML5652Pointek CLS300 - Digital - High Temperature
Rod version with Threaded or Flanged process
777 0 0 - 0 777
connection
Inverse frequency shift capacitance level switch
with optional rod/cable choices and configurable
output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions
where high pressure and temperatures are present.
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
5A
5B
5C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
5N
5P
5Q
2 x ½" NPT via adapter - cable inlet, IP65
2 x M20x1.5 cable inlet, IP65
2 x ½" NPT via adapter - cable inlet, IP68
2 x M20x1.5 cable inlet, IP68
Welded flange, 316L stainless steel,
Type A flat faced
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
6A
6B
6C
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
Active shield length
Standard length - (125 mm threaded, 105 mm flanged)
Extended shield (250 mm threaded, 230 mm flanged)2)
Extended shield (400 mm threaded, 380 mm flanged)3)
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
6G
6H
6J
6K
Add order code Y01 and plain text:
"Insertion length ... mm"
Extended rod, factory adjusted length
250 ... 499 mm (9.8 ... 19.65 inch)
Extended rod, factory adjusted length
500 ... 749 mm (19.69 ... 29.49 inch)
Extended rod, factory adjusted length
750 ... 999 mm (29.53 ... 39.3 inch)
Wetted seals
Graphite
5/56
Siemens FI 01 · 2012
B
C
D
E
F
G
H
J
Enclosure andlLid
Aluminum epoxy coated
1)
A
B
C
D
0
1
2
Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection
Available with Probe version options B to D, F, G only [≥ 500 mm
(19.69 inch)]
3)
Available with Probe version options C, D, and, G only [≥ 750 mm
2)
(29.53 inch)]
C) Subject to export regulations AL: N, ECCN: EAR99.
Probe length (length from flange face)
(threaded lengths include process thread)
Note: No Y01 needed in order code for standard
lengths
Standard version, rod 350 mm (13.78 inch)
Extended rod, length 500 mm (19.69 inch)
Extended rod, length 750 mm (29.53 inch)
Extended rod, length 1000 mm (39.37 inch)
0
A
B
C
D
E
F
G
0
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Order No.
Selection and Ordering data
Operating Instructions - Standard
English
C) 7ML1998-5JH04
German
Note: The Operating Instructions should be
ordered as a separate line on the order.
C) 7ML1998-5JH33
Quick Start manual, multi-language
C) 7ML1998-5QY83
Total insertion length: enter the total insertion length
in plain text description
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions - Digital
Operating Instructions
English
C) 7ML1998-5JJ04
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/57
French
C) 7ML1998-5JJ11
Accessories
See page 5/57
C) 7ML1998-5JJ33
German
Note: The Operating Instructions should be ordered as a separate line on the order.
Quick Start manual, multi-language
C) 7ML1998-5XA83
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
One metallic cable gland M20x1.5, -40 ... +80 °C
(-40 ... +176 °F) with integrated shield connection
(available for PROFIBUS PA)
7ML1930-1AQ
General Purpose
1/2" NPT General Purpose Cable Entry IP68/IP69K
NEMA6, -40 ... -100 °C (-40 ... -212 °F), cable size
6 ... 12 mm (0.236 ... 0.472 inch)
C) A5E03252530
M20x1.5 General Purpose Cable Entry IP68/IP69K
NEMA6,-40 ... -100 °C (-40 ... -212 °F), cable size
7 ... 12 mm (0.275 ... 0.472 inch)
C) A5E03252531
Hazardous Locations
1/2" NPT EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1,Zone 2, Zone 21, Zone 22, and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C
IP66,IP67,IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
A5E03252527
M20 EMC rated Cable Gland: Dust Ignition Proof,
Flameproof Exd, and Increased Safety ATEX II 2 GD
ExtD A21 (Zone 1,Zone 2, Zone 21, Zone 22 and in
Gas Groups IIA,IIB and IIC) -60 ... +80 °C
IP66,IP67,IP68, NEMA4X, cable sizes 5.5 ... 12 mm
(0.216 ... 0.472 inch)
A5E03252528
Blind threaded flanges are available. Please
contact [email protected] with a completed
application data sheet on page 5/9
Pointek Specials
See page 5/79
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/57
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
■ Characteristic curves
Pressure/Temperature Curve
CLS300 Extended Rod and Cable Probes
Threaded Process Connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
5
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
Example:
Permitted operating pressure = 30 bar (435 psi) at 75 °C
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Pressure/Temperature Curve
CLS300 High Temperature Rod Probes
Threaded Process Connections
(7ML5652 and 7ML5662)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
5/58
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
Pressure/Temperature Curve
CLS300 Extended Rod and Cable Probes
ASME Flanged Process Connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
5
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660, and 7ML5661)
Permitted Operating Pressures P
Pressure/Temperature Curve
CLS300 HighTemperature Rod Probes
ASME Flanged Process Connections
(7ML5652 and 7ML5662)
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
ASME 150 lb1)
atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
Siemens FI 01 · 2012
5/59
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
Pressure/Temperature Curve
CLS300 Extended Rod and Cable Probes
EN Flanged Process Connections
(7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
5
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5650, 7ML5651, 7ML5660 and 7ML5661)
Pressure/Temperature Curve
CLS300 High Temperature Rod Probes
EN Flanged Process Connections (7ML56552 and 7ML5662)
Permitted Operating Pressures P
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
Atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS300 Process Pressure/Temperature derating curves (7ML5652 and 7ML5662)
5/60
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
■ Dimensional drawings
Rod version
Threaded (7ML5650 and 7ML5660)
Lid
Thermal
isolator
185 (7.28)
171
(6.73)
Thermal
isolator
Y02 1)
Ø10 (0.35)
Stainless
steel weight
Y01 (insertion length)
min. = 500 (20)/max. = 25000 (984)
PFA insulated
cable
250 (9.84)
Y02
Y01 (insertion length)
min. = 500 (20)/max. = 25000 (984)
Measuring length
250 (9.84)
Ø6 (0.24)
Y02 1)
Cable version, insulated
Threaded (7ML5651 and 7ML5661)
1)
Stainless
steel cable
Ø32 (1.26)
Lid without window
Ø19 (0.75)
Cable version, non-insulated
Threaded (7ML5651 and 7ML5661)
Stainless
steel weight
Y01 (insertion length)
min. = 250 (9.8)/max. = 1000 (39.37)
Probe
Lid with window
Measuring length
Ø19 (0.75)
Ceramic
isolator(s)
M20: 135 (5.32)
½" NPT: 150 (5.91)
Measuring length
Y01 (insertion length)
min. = 250 (9.8)/max. = 1000 (39.37)
Y02 1)
Measuring length
Probe
2 cable entries
½" NPT or
M20 x 1.5
20 (0.79)
260 (10.24)
273 (10.75)
Lid clip
Electronics/
enclosure
High temperature rod version
Threaded (7ML5652 and 7ML5662)
Ø32 (1.26)
Note:
1)
Extended Active Shield (Y02): standard length 125 mm (4.92"). Optional active shield lengths: 250 mm (9.84") or 400 mm (15.75").
Pointek CLS300 dimensions -Threaded Process connections, dimensions in mm (inch)
Siemens FI 01 · 2012
5/61
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
Rod version
Welded flange (7ML5650 and 7ML5660)
High temperature rod version
Welded flange (7ML5652 and 7ML5662)
lid
lid clip
electronics/
enclosure
Ø19 (0.75)
185 (7.28)
lid without window
171
(6.73)
thermal
isolator
Ø19 (0.75)
Cable version, non-insulated
Welded flange (7ML5651 and 7ML5661)
Cable version, insulated
Welded flange (7ML5651 and 7ML5661)
Flange Facing (raised face)
Ø32 (1.26)
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
Y02
stainless steel
weight
measuring length
Ø10 (0.35)
Y01 (insertion length)
min. = 500 (20)/max. = 25000 (984)
1)
PFA insulated
cable
250 (9.84)
250 (9.84)
Ø6 (0.24)
Y01 (insertion length)
min. = 500 (20)/max. = 25000 (984)
stainless steel
cable
measuring length
Y02 1)
Flange Class
stainless steel
weight
Ø32 (1.26)
Note:
1)
Extended Active Shield (Y02): standard length 105 mm (4.13"). Optional active shield lengths: 230 mm (9.06") or 380 mm (14.96").
Insertion length does not include any raised face/gasket face dimension (see Flange Facing Table above)
Pointek CLS300 dimensions - Flanged Process connections, dimensions in mm (inch)
5/62
260 (10.24)
273 (10.75)
5
lid with window
Y01 (insertion length)
min. = 250 (9.8)/max. = 1000 (39.37)
probe
Y02 1)
Ceramic
isolator(s)
M20: 135 (5.32)
½" NPT: 150 (5.91)
measuring length
probe
thermal
isolator
Y01 (insertion length)
min. = 250 (9.8)/max. = 1000 (39.37)
measuring length
Y02 1)
2 cable entries
½" NPT or
M20 x 1.5
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS300 – Standard and Digital
■ Schematics
Wiring: Pointek CLS300 Standard
white
black
red
P2
(f )
(+)
switch bank
trip
point
S1
P1
K1
OFF
GND
3
+
delay
2
1
K4
sensor
L1
L2
L3
sensor
status
power
on
1
2
3
power
supply
12 to 250 V AC/DC
output
status
NC
NO
NO
K2
K3
solid state switch:
30 V DC/30 V AC
(peak),
82 mA max.
relay contact:
8 A at 250 V AC, 2000 VA
5 A at 30 V DC, 150 W
5
Notes:
- Identification label is on underside of lid. Switch and Potentiometer settings
are for illustration purposes only (Refer to Operation/Setup in manual).
- All field wiring must have insulation suitable for at least 250 V.
- Relay contact terminals are for use with equipment having no accessible live
parts and wiring having insulation suitable for at least 250 V.
- Maximum working voltage between adjacent relay contacts shall be 250 V.
- Refer to the Instruction Manual or contact Siemens representative for detailed
wiring information.
Wiring: Pointek CLS300 Digital
white
test input
reed
contact*
white
red (+)
black (-)
sensor
alarm output
solid-state switch
orange (f)
24 V DC/PROFIBUS PA
power connection:
24 V DC or PROFIBUS PA bus
(not polarity sensitive).
Notes:
Refer to the Instruction Manual or contact a Siemens representative
for detailed wiring information.
*Magnet Activated Sensor Test
A magnet can be used to test the sensor without opening the lid of the
Pointek CLS300 Digital version. Bring the magnet close to the test
area indicated on the enclosure. The sensor test starts and finishes
automatically after 10 seconds.
Pointek CLS300 connection
Siemens FI 01 · 2012
5/63
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
■ Overview
■ Configuration
Installation
5
Pointek CLS500 is an inverse frequency shift capacitance level
switch for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical conditions of high temperature and
pressure.
Keep unit out of path of falling material, or protect probe from
falling material.
■ Benefits
• Patented Active-Shield technology so measurement is unaffected by material buildup in active shield section
• 2-wire loop powered with solid-state switch or 4 to 20/20 to
4 mA output
• Simple push-button calibration and integrated local display
• Full function diagnostics
• HART communications for remote commissioning and inspection
Build up of material in active shield area does not affect
switch operation.
■ Application
Patented Active-Shield technology ensures that measurement is
unaffected by vapours, product deposits, dust and condensation. The unique mechanical probe design coupled with a high
performance transmitter gives superior performance in a wide
range of level detection applications.
Pointek CLS500’s microprocessor-based electronics provide
one-point calibration, making setup possible without shutting
down your production process.
• Key Applications: foam or liquid/foam level, glycol regenerators, high-pressure coalescers, LNG applications
50 (2)
Install probe at least 50 (2) from tank wall.
Pointek CLS500 installation, dimensions in mm (inch)
5/64
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
■ Technical specifications
Input
Design
Measuring range
0 ... 330 pF
Span
Min. 1 pF
Output
Solid-state switch
• Output
• Protection
• Max. switching voltage
• Max. load current
• Voltage drop
• Time delay
(pre or post switching)
Current loop
Galvanically isolated
Against reversed polarity (bipolar)
30 V (DC)
30 V peak (AC)
82 mA
< 1 V, typical at 50 mA
1 ... 60 s
4 ... 20 mA/20 ... 4 mA
Material
• Wetted parts material
- Standard rod
• Probe isolation (rod)
Probe diameter
• Standard rod version (PFA)
• High temperature rod version
(Stainless steel)
Probe length
• Standard rod version (PFA)
• High temperature rod version
(Stainless steel)
Accuracy (transmitter)
Temperature stability
0.15 pF (0 pF) or < 0.25% (typical
< 0.1%) of actual measurement
value, whichever is greater over
the full temperature range
Non-linearity and repeatability
0.1% of full scale and actual
measurement respectively
Accuracy
Deviation < 0.1% of measured
value
Rated operating conditions 1)
Installation conditions
- Location
Indoor/outdoor
Ambient conditions
• Ambient temperature (transmitter)
• Installation category
• Pollution degree
-40 ... +85 °C (-40 ... +185°F)2)
I
4
Medium conditions
• Relative dielectric constant εr
• Process temperature
- Standard (PFA)
- High temperature stainless steel
version with thermal isolator
- Cryogenic version
Process pressure
• Standard (PFA)
• High temperature version
(Stainless steel)
Process connection of probe
• Threaded mounting
• Flange mounting
Enclosure
• Material
Max. 1000 mm (39.4 inch) with
16 mm (0.63 inch) diameter
probe
Max. measuring length 1000 mm
(39.4 inch) with 19 mm (0.75 inch)
diameter probe
NPT [(Taper), ANSI/ASME
B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
ASME, EN 1092-1
• Cable inlet
• Degree of protection
Power supply
Max. 33 V DC
Features
Safety
• Diagnostics with fault alarm when:
-200 to +200 °C (-328 ... +392 °F)
Contact [email protected]
for details.
Pressure rating of process seal is
temperature dependent.
See Pressure/Temperature curves
on page 5/71.
-1 ... +150 bar g
(-14.6 ... +2175 psi g)
-1 ... +35 bar g
(-14.6 ... +507.6 psi g)
16 mm (0.63 inch)
19 mm (0.75 inch)
Aluminium, epoxy-coated
(Stainless steel option available.
Contact [email protected])
2 x ½" NPT
Type 4X/NEMA4X/IP65, IP68
Measurement current signalling
Min. 1.5
Temperature ratings are pressure
dependent. See Pressure/Temperature curves on page 5/71.
-50 ... +200 °C (-58 ... +392 °F)
-60 ... +400 °C (-76 ... +752 °F)
316L stainless steel
PFA
• Function rotary switch
• SMART communication
NAMUR NE 43
Inputs/outputs fully galvanically
isolated
Polarity-insensitive current loop
Fully potted
Integrated safety barrier
Primary variable (PV) out of limits,
system failure in measurement
circuit, deviation between A/D
and D/A converter, check sum,
watch dog and self-checking
facility
Positions 0 to 9, A to F
Conforming to HART Communication Foundation (HCF)
Siemens FI 01 · 2012
5/65
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Certificates and approvals
General Purpose
CE, CSA/FM, C-TICK
Non incendive/Non sparking
CSA/FM Class I, Div. 2, Groups A,
B, C, D T4
ATEX II 3G 2D EEx n A [ib] IIC T6
to T4 T100 °C
Dust Ignition Proof
CSA/FM Class II and III, Div. 1,
Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] T6 to T1
T100 °C
Explosion Proof
FM Class 1, Div. 1, Groups A, B,
C, D T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to
T1 T100 °C
Marine
Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3,
ENV5, Bureau Veritas
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate.
See also Pressure/Temperature curves on page 5/71.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F)
5
Pointek CLS500 probe version
Standard
HT Series
Process connection types
Standard (PFA)
(7ML5601, 7ML5602, 7ML5603)
High Temperature (Enamel or Stainless steel)
(7ML5604)
Threaded
Available as standard
–
Flange
Available as standard
Available as standard
Available as standard
Available as standard
None
–
HT Stainless: available as standard
PFA
Available as standard
–
1000 mm (40 inch)
1000 mm (40 inch)
Max. process pressure
150 bar g (2175 psi g)
Stainless steel:2) 35 bar g (507 psi g)
Max. process temperature
+200 °C (+392 °F)
+400 °C (+752 °F)
Process connection materials
316L stainless steel
Probe insulation
Length parameters
Max. rod length
Process
condtitions1)
1)
When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page 5/71.
Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page 5/71.
2) Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page 5/71.
– Not available as standard
5/66
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Selection and Ordering data
Order No.
Order No.
Selection and Ordering data
C) 7ML5601Pointek CLS500, threaded
Inverse frequency shift capacitance level switch for
7 7 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of
extreme temperature and pressure.
C) 7ML5602Pointek CLS500, welded flange
Inverse frequency shift capacitance level switch for
77 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of
extreme temperature and pressure.
Electronic transmitter
No transmitter supplied
MSP 2002-1 (330 pF)
Electronic transmitter
MSP 2002-1 (330 pF)
0
1
Process connection
¾"
1"
1¼"
A
B
C
1½"
2"
D
E
Threaded connection and rating
NPT [(Taper), ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T) JIS B 0203]
G [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
4" ASME, 150 lb1)
4" ASME, 300 lb1)
6" ASME, 150 lb1)
6" ASME, 300 lb1)
Welded flange, 316L stainless steel,
Type A flat faced
DN 50 PN 16
DN 50 PN 40
DN 80 PN 16
A
B
D
Probe insulation/material of process connection
PFA insulation/316L stainless steel
1
Approvals
General Purpose: CE, CSA/FM, C-TICK
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3GD 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
1
2
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
4
6
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, minimum insertion
length 200 mm (7.9 inch), maximum insertion
length 1000 mm (39.4 inch)1)
EC
ED
FC
FD
GC
HC
Probe insulation/material of process connection
PFA insulation/316L stainless steel
1
A
B
Add order code Y01 and Y02 in plain text:
"Insertion/active shield length to mm"
Approvals
General Purpose
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
Probe/electrode diameter
16 mm (0.63 inch) rigid rod, min. length 200 mm
(7.9 inch), max. length 1000 mm (39.4 inch)
C) Subject to export regulations AL: N, ECCN: EAR99.
Selection and Ordering data
AA
AB
BA
BB
CA
CB
DA
DB
DN 80 PN 40
DN 100 PN 161)
DN 125 PN 161)
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
Thermal isolator/remote version
Rigid thermal isolator [for process connection
temperature over +85 °C (+185 °F)]
No thermal isolator
1)
1
Process connection and pressure rating
Welded flange, 316L stainless steel, raised face
2" ASME, 150 lb
2" ASME, 300 lb
3" ASME, 150 lb
3" ASME, 300 lb1)
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Thermal isolator
Rigid thermal isolator
[for process temperature over +85 °C (+185 °F)]
No thermal isolator
1)
Total insertion length: enter the total insertion length
in plain text description
Y01
Active Shield length - minimum length is 50 mm
Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
5
1
1
2
4
6
1
A
B
Custom shipping methods required. Contact factory for more details.
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/70
Pointek Specials
See page 5/79
1)
See dimension drawings on page 5/76 for further explanation of Y02
Siemens FI 01 · 2012
5/67
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Active Shield length - minimum length is
50 mm.Y02: to mm1)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
Inspection Certificate Type 3.1 per EN 10204
Operating Instructions
Note: The Operating Instructions should be ordered as a separate line on the order.
Y01
1)
Electronic transmitter
MSP 2002-1 (330 pF)
Y15
Process connection and pressure rating
Single piece flange, 316L stainless steel,
raised face
2" ASME, 150 lb
2" ASME, 300 lb
AA
AB
3" ASME, 150 lb
3" ASME, 300 lb1)
BA
BB
4" ASME, 150 lb1)
4" ASME, 300 lb1)
CA
CB
6" ASME, 150 lb1)
6" ASME, 300 lb1)
Single piece flange, 316L stainless steel,
Type B1 raised faced
DA
DB
DN 50 PN 16
DN 50 PN 25
EC
ED
DN 80 PN 16
DN 80 PN 25
FC
FD
DN 100 PN 161)
DN 100 PN 251)
GC
GD
DN 125 PN 161)
HC
C11
C12
See page 5/70
See page 5/79
See dimensional drawings on page 5/76 for further explanation of Y02
5
Probe insulation/material of process connection
PFA insulation/316L stainless steel
1
1
2
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
4
6
Thermal isolator
Rigid thermal isolator [for process connection temperature over +85 °C (+185 °F)]
No thermal isolator
1)
1
A
B
Custom shipping methods required. Contact factory for more details
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
1
Approvals
General Purpose: CE, CSA/FM, C-TICK
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
Probe/electrode diameter
16 mm (0.63 inch) rigid rod,
maximum length 1000 mm (39.4 inch) (Y01)
5/68
Order No.
C) 7ML5603Pointek CLS500, single piece flange
Inverse frequency shift capacitance level switch for
77 7 77 - 77 A 0
detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of
extreme temperature and pressure.
Y02
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
Pointek Specials
Selection and Ordering data
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Order No.
Selection and Ordering data
C) 7ML5604Pointek CLS500 High temperature
Inverse frequency shift capacitance level switch for
7 A 7 77 - 7 77 7
detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of
extreme temperature and pressure.
Total insertion length: enter the total insertion length
in plain text description
Y01
Active Shield length - minimum length is
50 mm.Y02: to mm1)
Y02
Electronic transmitter
MSP 2002-1 (330 pF)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Process connection and pressure rating
316L stainless steel, raised face1)
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
2" ASME, 900 lb
A1
A2
A3
A4
3" ASME, 150 lb
3" ASME, 300 lb2)
3" ASME, 600 lb2)
3" ASME, 900 lb2)
B1
B2
B3
B4
4" ASME, 150 lb2)
4" ASME, 300 lb2)
4" ASME, 600 lb2)
4" ASME, 900 lb2)
C1
C2
C3
C4
6" ASME, 150 lb2)
6" ASME, 300 lb2)
6" ASME, 600 lb2)
6" ASME, 900 lb2)
316L stainless steel, Type B1 flat faced
D1
D2
D3
D4
DN 50 PN 16
DN 50 PN 25
DN 50 PN 40
DN 50 PN 63
E1
E2
E3
E4
DN 80 PN 16
DN 80 PN 25
DN 80 PN 402)
DN 80 PN 632)
F
F
F
F
DN 100 PN 162)
DN 100 PN 252)
DN 100 PN 402)
DN 100 PN 632)
G1
G2
G3
G4
DN 125 PN 162)
DN 125 PN 252)
DN 125 PN 402)
DN 125 PN 632)
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 standard.)
H1
H2
H3
H4
Operating Instructions
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and manual library.
See page 5/70
Accessories
See page 5/79
1)
See dimensional drawings on page 5/76 for further explanation of Y02
1
Siemens FI 01 · 2012
5
1
2
3
4
5/69
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Selection and Ordering data
Order No.
Selection and Ordering data
C) 7ML5604Pointek CLS500 High temperature
Inverse frequency shift capacitance level switch for
7 A 7 77 - 7 777
detecting interfaces, solids, liquids, toxic and
aggressive chemicals in critical conditions of
extreme temperature and pressure.
Probe material of process connection
No insulation/316L stainless steel3)4)
Stilling well
No stilling well
0
Approvals
General Purpose
CSA/FM Class I, Div. 2, Groups A, B, C, D T4;
ATEX II 3G 2D EEx nA [ib] IIC T6 to T4 T100 °C;
CSA/FM Class II and III Div. 1, Groups E, F, G T4
A
B
ATEX II 1/2 GD EEx d [ia] IIC T6 to T1 T100 °C
FM Class I, Div. 1, Groups A, B, C, D T4
D
F
Probe/electrode diameter
Maximum length 1000 mm (39.37 inch)4)
Thermal isolator
Rigid thermal isolator
5
1
1)
3)
C) Subject to export regulations AL: N, ECCN: EAR99.
5/70
Siemens FI 01 · 2012
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: enter the total insertion length
in plain text description
Y01
Active Shield length - minimum length is
50 mm.Y02: to mm1)
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
English
German
A
1
Welded flange for no insulation option only
Custom shipping methods required
Non-conductive material only, stainless steel non-insulated probe diameter
19 mm (0.75 inch)
4)
Add order code Y01 and Y02 in plain text:
"Insertion/active shield length to mm"
Minimum insertion length depends on probe version selected.
See dimensional drawings on page 5/76 for more details.
2)
Order code
Further designs
C) 7ML1998-5GG02
C) 7ML1998-5GG32
French
7ML1998-5GG11
Dutch
Note: The Operating Instructions should be ordered
as a separate line on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
7ML1998-5GG41
Pointek Specials
See page 5/79
1)
See dimensional drawings on page 5/76 for further explanation of Y02
C) Subject to export regulations AL: N, ECCN: EAR99.
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
■ Characteristic curves
Pressure/temperature curve
CLS500 rod probes
Threaded process connections
(7ML5601)
Permitted operating pressures P
150 bar (2.175 psi)
140 bar (2.030 psi)
130 bar (1.885 psi)
120 bar (1.740 psi)
110 bar (1.595 psi)
5
100 bar (1.450 psi)
90 bar (1.305 psi)
80 bar (1.160 psi)
70 bar (1.015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
Atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
-29 ºC
(-20 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted operating temperature T
Example:
Permitted operating pressure = 137 bar (1988 psi) at 75 °C
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5601)
Siemens FI 01 · 2012
5/71
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Pressure/Temperature Curve
CLS500 Rod Probes
ASME Flanged Process Connections
(7ML5602 and 7ML5603)
Permitted Operating Pressures P
150 bar (2,175 psi)
140 bar (2,030 psi)
130 bar (1,885 psi)
120 bar (1,740 psi)
110 bar (1,595 psi)
100 bar (1,450 psi)
5
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)
5/72
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Pressure/Temperature curve
CLS500 Rod Probes
EN Flanged process connections
(7ML5602 and 7ML5603)
Permitted Operating Pressures P
150 bar (2,175 psi)
140 bar (2,030 psi)
130 bar (1,885 psi)
120 bar (1,740 psi)
110 bar (1,595 psi)
100 bar (1,450 psi)
5
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
PN 251)
atmospheric
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5602 and 7ML5603)
Siemens FI 01 · 2012
5/73
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Pressure/Temperature Curve
CLS500 HighTemperature (no insulation)
ASME Flanged Process Connections
(7ML5604)
Permitted Operating Pressures P
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
5
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
ASME 150 lb1)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)
5/74
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Pressure/Temperature Curve
CLS500 HighTemperature (no insulation)
EN Flanged Process Connections
(7ML5604)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
PN 251)
atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
PN 161)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
Pointek CLS500 Process Pressure/Temperature derating curves (7ML5604)
Siemens FI 01 · 2012
5/75
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
■ Dimensional drawings
Standard rod version
Threaded (7ML5601)
205 (8.1)
Standard configuration
(7ML5601)
Transmitter/
electronics
1/2" NPT:
230 (9.1)
Inactive tip
Ø16 (0.63)
Pointek CLS500 dimensions - Threaded Process connections, dimensions in mm (inch)
5/76
Siemens FI 01 · 2012
Thermal
isolator
430 (16.9)
With thermal isolator option
(all versions)
270 (10.6)
With explosion-proof seal option
(all versions)
Measuring length
PFA insulated
probe
30 (1.18)
5
Y02
Y01 (insertion length)
min. = 200 (7.87) / max. = 1000 (39.37)
20 (0.79)
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
Standard Rod version
Welded Flange (7ML5602)
Single Piece Flange (7ML5603)
205 (8.1)
Standard configuration
(7ML5602, 7ML5603)
transmitter/
electronics
With explosion-proof seal option
(all versions)
With thermal isolator option
(all versions)
430 (16.9)
270 (10.6
Y01 (insertion length)
min. = 200 (7.87)/max. = 1000 (39.37)
30 (1.18)
PFA insulated
probe
measuring length1)
Y021)
½" NPT:
230 (9.1)
thermal
isolator
5
inactive tip
Ø16 (0.63)
High temperature rod version
Welded Flange (7ML5604), Stainless steel rod 4)
Flange Facing (raised face)
Flange Class
thermal
isolator
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/25/40/64
2 (0.08)
Notes:
1)
Min. Y02 (active shield length) = 50 (1.96)
Min. Y02 (active shield length) = 105 (4.13)
3)
Min. Y02 (active shield length) = 100 (3.94)
4)
Non conductive materials only
stainless steel
probe
measuring
Y02 2)
length2)
Y01 (insertion length)
min. = 200 (7.87)/max. = 1000 (39.37)
2)
Insertion length does not include any raised
face/gasket face dimension (see Flange
Facing Table above)
Ø19 (0.75)
Pointek CLS500 dimensions - Flanged Process connections, dimensions in mm (inch)
Siemens FI 01 · 2012
5/77
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pointek CLS500
■ Schematics
Ground lug
Protective
label
Instrument
system
ground
Measuring
signal
(mini-coaxial
cable)
Ground connection point
for instrument system
5
Pointek CLS500 connections
5/78
Siemens FI 01 · 2012
Solid state
switch relay
(any polarity)
4-20 mA
Current loop
connection
(any polarity)
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pontek CLS Specials
■ Selection and ordering data
Pointek Specials. See note 1.
Pointek Specials. See note 1.
Order No.
Kit, Sensor for cable units, PPS, Digital, FKM
C)
A5E01163678
Kit, Sensor for cable units, PPS, Standard,
FFKM
C)
A5E01163679
Kit, Sensor for cable units, PPS, Digital, FFKM
C)
A5E01163680
Kit, Sensor for cable units, PVDF, Standard,
FKM
C)
A5E01163681
Kit, Sensor for cable units, PVDF, Digital, FKM
C)
A5E01163682
Kit, Sensor for cable units, PVDF, Standard,
FFKM
C)
A5E01163683
CLS100 Miscellaneous Parts
Kit, Sensor for cable units, PVDF, Digital, FFKM
C)
A5E01163684
Custom length of cable is available only for
7ML5501-xxx1x and 7ML5501-xxx5x
CLS200 Mounting Bracket,
316L stainless steel
CLS100 Polycarbonate Lid and Gasket, FKM
Kit, Lid and gasket,
CLS100 enclosure version
F)
A5E01163671
See note 2
CLS200 Gasket (IP65), Synprene
Spare gasket, enclosure version
(IP65 versions only)
F)
A5E01163672
Spare mounting bracket
A5E01163685
CLS200 PROFIBUS Connector (IP65)
CLS200 Gasket (IP68), Silicone
Spare, PROFIBUS connector
(IP65 versions only)
Spare gasket, enclosure version
(IP68 versions)
F)
A5E01163673
A5E01163686
CLS200 Miscellaneous Parts
CLS200 with FFKM O-rings (any version)
CLS200 Blind Lid
See note 2
CLS200 Electronics
Test magnet, digital version
7ML1830-1JE
Amplifier/power supply kit, standard version
C)
A5E03251681
Amplifier/power supply, digital version
L)
7ML1830-1JF
LCD display, digital version
Spare aluminum blind lid
(for standard versions only)
A5E01163674
7ML1830-1JK
CLS300 Cable Extensions, 316L stainless
steel
CLS200 Lid with window
Spare aluminum lid with window
A5E01163676
CLS200 Sensor Kit for cable units
Kit, Sensor for cable units, PPS, Standard,
FKM
C)
A5E01163677
Kit, Stainless steel cable extension, 1 m,
adjustable by customer
A5E01163688
Kit, Stainless steel cable extension, 3 m,
adjustable by customer
A5E01163689
Kit, Stainless steel cable extension, 5 m,
adjustable by customer
A5E01163690
Kit, Stainless steel cable extension, 10 m,
adjustable by customer
A5E01163691
Kit, Stainless steel cable extension, 15 m,
adjustable by customer
A5E01163693
Kit, Stainless steel cable extension, 20 m,
adjustable by customer
A5E01163695
Siemens FI 01 · 2012
5/79
5
© Siemens AG 2011
Level Measurement
Point level measurement — Capacitance switches
Pontek CLS Specials
Pointek Specials. See note 1.
Pointek Specials. See note 1.
CLS300 Cable Extensions, 316 stainless
steel with PFA coating
CLS300 Electronics Kits with drivers
(for cable versions)
Kit, PFA cable extension, 1 m,
adjustable by customer
A5E01163697
Kit, PFA cable extension, 3 m,
adjustable by customer
A5E01163698
Kit, PFA cable extension, 5 m,
adjustable by customer
A5E01163699
Kit, Electronics with driver, standard CLS300.
To be used in cable versions with length
greater than 5 m. See notes3 and 4.
C)
A5E01163724
Kit, Electronics with driver, digital CLS300.
To be used in cable versions with length
greater than 5 m. See notes 3 and 4.
C)
A5E01163726
CLS300 Electronics
Kit, PFA cable extension, 10 m, adjustable by
customer
A5E01163700
Kit, PFA cable extension, 15 m,
adjustable by customer
A5E01163701
Kit, PFA cable extension, 20 m,
adjustable by customer
A5E01163702
Test magnet, digital version
7ML1830-1JE
Amplifier/power supply kit, standard version
C)
A5E03251683
Amplifier/power supply, digital version
L)
7ML1830-1JF
LCD display, digital version
7ML1830-1JK
CLS300 Weight Kit, 316L stainless steel
CLS300 Rod Kits, 316L stainless steel
5
Kit, Spare stainless steel weight. To be used in
any cable version of CLS300
A5E01163727
Kit, Stainless steel rod 180 mm (7.09 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 350 mm (13.78 inch).
A5E01163719
Kit, Stainless steel rod 330 mm (12.99 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 500 mm (19.69 inch).
A5E01163720
Kit, Stainless steel rod 580 mm (22.83 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 750 mm (29.53 inch).
A5E01163721
CLS500 Blind Lid
Kit, Stainless steel rod 830 mm (32.68 inch) to
be used with CLS300 units only (with standard
active shield). Insertion length after installation
is 1000 mm (39.37 inch).
A5E01163722
Spare CLS500 aluminum blind lid
Kit, Stainless steel rod 1330 mm (52.36 inch)
to be used with CLS300 units only (with standard active shield). Insertion length after installation is 1500 mm (59.06 inch).
See note 2
Kit, Stainless steel rod 1830 mm (72.05 inch)
to be used with CLS300 units only (with standard active shield). Insertion length after installation is 2000 mm (78.74 inch).
See note 2
Note 1: Special flange sizes and facings are available. Please contact
[email protected] for part number and pricing. Submit Application Questionnaire found on page 5/9.
Note 2: Please contact [email protected] for part number and pricing.
Note 3: For General Purpose approvals only.
Note 4: To maintain approvals, qualified trained Siemens personnel required
for part replacement.
Please contact [email protected] for special requests.
Kit, Stainless steel rod customized length
up to 1 m
See note 2
C) Subject to export regulations AL: N, ECCN: EAR99.
Kit, Stainless steel rod customized length
up to 2 m
See note 2
Spare gasket, CLS500 enclosure version, IP65
Transmitter, MSP 2002-1, 330 PF
A5E01163729
L)
7ML1830-1JP
F) Subject to export regulations AL: 91999, ECCN: N.
J) Subject to export regulations AL: 91999, ECCN: EAR99.
L) Subject to export regulations AL: N, ECCN: 3A991X.
Kit, Electronics with driver, standard CLS300.
To be used in rod or cable versions with length
less than 5 m. See notes 3 and 4.
C)
A5E01163723
Kit, Electronics with driver, digital CLS300.
To be used in rod or cable versions with length
less than 5 m. See notes 3 and 4.
C)
A5E01163725
Siemens FI 01 · 2012
A5E01163728
CLS500 Electronics Kit
CLS300 Electronics Kits with drivers
(for rod or cable versions)
5/80
CLS500 Gasket (IP65), Silicone
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
■ Overview
■ Configuration
Horizontal mounting
switching point
switching point
(recommended mounting
position, particularly for
adhesive applications)
Vertical mounting
13 (0.51)
SITRANS LVL100 is a compact vibrating level switch for use in
liquid and slurry applications such as overflow, high, low, and
demand applications, as well as pump protection. It is ideal for
use in confined spaces.
13 (0.51)
switching point
with
lower density
switching point
[approx. 13 (0.51)]
5
■ Benefits
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57 inch) for confined
space applications
• Fault monitoring for corrosion, loss of vibration, or line break to
the piezo drive
• Integrated test function to confirm correct operation
■ Application
SITRANS LVL100 is a compact level switch designed for industrial use in all areas of process technology and can be used with
liquids and slurries. With an insertion length of only 40 mm
(1.57“), SITRANS LVL100 can be mounted in small pipes and
confined space applications. It is virtually unaffected by the
chemical and physical properties of the liquid. The LVL100 can
be used in difficult conditions including turbulence, air bubbles,
foam generation, buildup, or external vibration.
The tuning fork is piezoelectrically energized and vibrates at a
mechanical resonance frequency of approximately 1200 Hz.
The vibration frequency changes when the tuning fork is covered by the medium. This change is detected by the integrated
oscillator and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal to connected devices.
• Key Applications: For use in liquids and slurries, for level measurement, overfill, and dry run protection
switching point
with
higher density
Horizontal mounting in
viscous or adhesive
applications
Moisture protection
30 (1.18)
NOTE:
Welded socket for flush
mount optional.
Ensure cable gland faces
downward to avoid water
ingress.
SITRANS LVL100 Installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/81
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
■ Technical specifications
■ Options
Mode of operation
Measuring principle
Vibrating point level switch
LVL100 Threaded Welded Socket
G¾" A/316L
Measured variable
High and low, and demand
Measuring Accuracy
Hysteresis
approx. 2 mm (0.08 inch) with
vertical installation
Switching delay
approx. 500 ms (on/off)
Frequency
approx. 1200 Hz
Rated operating conditions
5
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +70 °C (-40 ... +158 °F)
III
2
Medium conditions
• Temperature
- Standard
- High temperature option
• Pressure (vessel)
• Density
-40 ... +100 °C (-40 ... +212 °F)
-40 ... +150 °C (-40 ... +302 °F)
-1 to 64 bar g (-14.5 to 928 psi g)
0.7 to 2.5 g/cm³
(0.025 to 0.09 lbs/in³)
Design
Material
• Enclosure
• Tuning fork
• Process connection (threaded)
• Process seal
• Process connection
• Pipe thread, cylindrical
(ISO 228 T1)
• Pipe thread, tapered
• Hygienic fittings
316L and Plastic PEI
316L (1.4404 or 1.4435)
316L (1.4404 or 1.4435)
Klingersil C-4400
G ¾" A or G 1" A
¾" NPT or 1" NPT
Bolting DN40 PN40
Tri-clamp 1", 1½", 2" PN 10
Degree of protection
IP65/Type 4/NEMA 4
(with DIN 43650 valve plug),
IP66/67 or IP68
(with M12 connector)
Conduit entry
1 x M12 [IP66/IP67 or IP68
(0.2 bar)]
Weight (housing)
250 g (9 oz)
Power supply
Supply voltage
20 ... 253 V AC, 50/60 Hz
20 ... 253 V DC
Power consumption
1 to 8 VA (AC), approx. 1.3 W
(DC)
Certificates and approvals
• Overfill protection (WHG)
• Shipping approvals
5/82
Siemens FI 01 · 2012
32
(1.26)
Contactless electronic switch
Transistor output PNP
39 (1.54)
G1"
32 (1.26)
G¾"
Output
Output options
G1" A/316L
29,5
(1.16)
Input
53 (2.09)
60 (2.36)
SITRANS LVL100 welded socket, dimensions in mm (inch)
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
Selection and Ordering data
Order No.
Selection and Ordering data
SITRANS LVL100
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
Ideal for use in confined spaces.
7ML5748-
Further designs
7 7 7 77 - 77 A 0
Please add "-Z" to Order No. and specify Order
code(s).
Approvals
Without approvals
Shipping approvals1)
Overfill protection (WHG)2)
1
2
3
Process temperature
Standard -40 ... +100 °C (-40 ... +212 °F)3)
Extended -40 ... +150 °C (-40 ... +302 °F)3)
Hygienic applications -40 ... +150 °C
(-40 ... +302 °F)4)
Cleaning including certificate
(oil, grease and silicone free)
W01
Identification Label, foil laser marking
Y16
Acceptance test certificate 2.2 for instrument
C14
Additional Operating Instructions
Order No.
LVL100 (Contactless electronic switch)
A
B
C
Process connection
Thread G¾" A PN64/316L
Thread G¾" A PN64/316L Ra< 0.8 µm5)
Thread ¾" NPT PN64/316L
A0
A1
A2
Thread ¾" NPT PN64/316L Ra< 0.8 µm5)
Thread G1" A PN64/316L
Thread G1" A PN64/316L Ra< 0.8 µm5)
A3
A4
A5
Thread 1" NPT PN64/316L
Thread 1" NPT PN64/316L Ra< 0.8 µm5)
Tri-Clamp 1" PN16 DIN 32676/316L Ra< 0.8 µm5)
A6
A7
A8
µm5)
Order code
• English
7ML1998-5KN01
• French
7ML1998-5KN11
• Spanish
7ML1998-5KN21
• German
7ML1998-5KN31
LVL100 (Transistor PNP)
• English
7ML1998-5KP01
• French
7ML1998-5KP11
• Spanish
7ML1998-5KP21
• German
This device is shipped with the Siemens
Milltronics manual CD containing the complete
Operating Instructions library.
7ML1998-5KP31
Tri-Clamp 1½" PN16 DIN 32676/316L Ra< 0.8
Tri-Clamp 2" PN16 DIN 32676/316L Ra< 0.8 µm5)
Bolting DN25 PN40 DIN 11851/316L Ra< 0.8 µm5)
B0
B1
B2
Bolting DN40 PN40 DIN 11851/316L Ra< 0.8 µm5)
Bolting DN50 PN25 DIN 11851/316L Ra< 0.8 µm5)
SMS DN38 PN6 SMS1145/316L Ra< 0.8 µm5)
B3
B4
B5
G ¾" A/316L with FKM Seal
7ML1930-1EE
G 1 A/316L with FKM Seal
7ML1930-1EF
Hygienic fitting with compression nut F405)
PN25/316L Ra < 0.8 µm
B6
M27x1.5/316L with FKM Seal
7ML1930-1EG
G ¾ A/316L with EPDM Seal
7ML1930-1EH
G 1 A/316L with EPDM Seal
7ML1930-1EJ
M27x1.5/316L with EPDM Seal
7ML1930-1EK
Electronics
Contactless electronic switch 20 ... 250 V AC/DC6)
Transistor output PNP 10 ... 55 V DC
Housing
316L
Spare Parts
LVL100 Threaded Welded Socket
1
2
1
Electrical connection/Protection
M12x1/IP67
According to DIN 43650 including plug/IP65
Acc. to DIN 43650 incl. plug with QuickOn connection/IP65
A
B
C
M12x1 incl. 5 m cable/IP68 (0.2 bar)
D
1)
2)
3)
4)
5)
6)
Available with Process Temperature option A only
Available with Electronics option 2 only
Available with process connection A0, A2, A4, and A6 only
Available with process connection A1, A3, A5, and A7 to B6 only
Available with Process Temperature option C only
Available with Electrical connection/Protection option B and C only
Siemens FI 01 · 2012
5/83
5
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
■ Characteristic curves
Ambient temperature in °C (°F)
Ambient Temperature to Process Temperature dependency
(Standard version)
70 ºC
(158 ºF)
50 ºC
(122 ºF)
0 ºC
(32 ºF)
-40 ºC
(-40 ºF)
-40 ºC
(-40 ºF)
5
-20 ºC
(-4 ºF)
0 ºC
20 ºC
40 ºC
60 ºC
80 ºC 100 ºC
(32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF)
Process temperature in °C (°F)
Ambient temperature in °C (°F)
Ambient Temperature to Process Temperature dependency
(High temperature version)
70 ºC
(158 ºF)
0 ºC
(32 ºF)
-40 ºC
(-40 ºF)
-40 ºC
(-40 ºF)
-20 ºC
(-4 ºF)
0 ºC
20 ºC
40 ºC
60 ºC
80 ºC 100 ºC 120 ºC 140 ºC 150 ºC
(32 ºF) (68 ºF) (104 ºF) (140 ºF) (176 ºF) (212 ºF) (248 ºF) (284 ºF) (302 ºF)
Process temperature in °C (°F)
SITRANS LVL100 Ambient Temperature/Process Temperature derating curves
5/84
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
■ Dimensional drawings
SITRANS LVL100 (standard)
SITRANS LVL100 (extended high temperature)
36 (1.42)
27 (1.06)
Thread G ¾” A, G 1” A (DIN ISO 228/1),
¾” NPT or 1” NPT (valve plug DIN 43650)
Tri-clamp (valve plug DIN 43650)
35 (1.38)
Ø 31.7
(1.25)
158 (6.22)
32
Ø 31.7
(1.25)
~ 88 (3.46)
G 1" A
~ 101 (3.98)
32
Ø 21.3 (0.84)
L
40 (1.57)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
Ø 21.3 (0.84)
Switching point
L
13 (0.51)
L=
Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G 1” A, 1” NPT: 69 (2.7)
SITRANS LVL100 (standard with M12 connector)
5
L
40 (1.57)
Switching
point
L=
13 (0.51) Length with G ¾” A, ¾“ NPT: 66 (2.6)
Length with G 1“ A, 1” NPT: 69 (2.7)
Length with Tri-clamp: 53 (2.1)
SITRANS LVL100 (extended, high temperature)
Bolting DIN 11851 (valve plug DIN 43650)
SMS 1145 (valve plug DIN 43650)
10 (0.39)
M12 x 1
~ 115 (4.53)
~ 105 (4.13)
Ø 31.7
(1.25)
32
158 (6.22)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
L
Ø 21.3 (0.84)
40(1.57)
L
40 (1.57)
L
Switching
point
Switching point
13 (0.51)
L=
Length with G ¾” A, ¾” NPT: 66 (2.6)
Length with G 1“ A, 1” NPT: 69 (2.7)
13 (0.51)
L=
Length with bolting: 53 (2.1)
Length with SMS 1145: 53 (2)
SITRANS LVL100, dimensions in mm (inch)
Siemens FI 01 · 2012
5/85
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL100
■ Schematics
Transistor PNP (M12 x 1 plug connection)
1
Transistor PNP (with valve plug DIN 43650)
2
1
Max.
2
4
2
1
2
Max.
Min.
3
2
Min.
1
2
1
3
4
3
3
4
RL
RL
RL
2
1
3
RL
5
10 ... 55 V DC
10 ... 55 V DC
10 ... 55 V DC
PA (potential equalization)
Contactless electronic switch (valve plug DIN 43650)
Min.
Max.
2
1
2
1
3
3
RL
RL
L1
N
PE (protective ground)
SITRANS LVL100 connections
5/86
Siemens FI 01 · 2012
L1
PE
N
10 ... 55 V DC
PA
3
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Overview
■ Configuration
Horizontal mounting
marked with screwed version on top,
with flange versions directed to the
flange holes
switching point
(recommended
mounting position,
particularly for
adhesive applications)
Vertical mounting
switching point
with lower
density
SITRANS LVL200 is a standard vibrating level switch for use in
liquid and slurry applications such as overflow, high, low, and
demand applications, as well as pump protection. For use in
SIL-2 applications.
■ Benefits
switching point
[approx.
13 (0.51)]
switching point
with higher
density
• Proven vibrating level switch technology for liquids
• Compact insertion length of 40 mm (1.57 inch) for confined
space applications
• Fault monitoring for corrosion, loss of vibration or line break to
the piezo drive
• SIL-2 qualified for high level and dry run applications
• Hygienic process connections
■ Application
switching point
[approx.
27 (1.06)]
Mount away from filling
openings or agitators.
SITRANS LVL200 is a level switch designed for industrial use in
all areas of process technology and can be used with liquids
and slurries. With a tuning fork insertion length of only 40 mm
(1.57“), SITRANS LVL200 can be mounted in small pipes and
applications with confined space. The LVL200 can be used to
measure products with a minimum density of > 0.5 g/cm³
(0.018 lbs/in³). The LVL200 can be used in difficult conditions
including turbulence, air bubbles, foam generation, buildup, or
external vibration.
SITRANS LVL200 continuously monitors faults via frequency
evaluation, providing early detection of strong corrosion or damage on the tuning fork, loss of vibration, or a line break to the
piezo drive.
The tuning fork is piezoelectrically energized and vibrates at its
mechanical resonance frequency of approx. 1200 Hz. The vibration frequency changes when the tuning fork is covered by the
medium. This change is detected by the integrated oscillator
and converted into a switching command. The integrated electronics evaluate the level signal and output a switching signal,
directly operating connected devices.
• Key Applications: For use in liquids and slurries, for level measurement, overfill, and dry run protection
Moisture protection
NOTE:
Welded socket for flush mount optional
Ensure cable gland
faces downward to
avoid water ingress.
SITRANS LVL200 installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/87
5
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Technical specifications
Degree of protection
Mode of operation
Measuring principle
Vibrating point level switch
Conduit entry
Input
Measured variable
High and low, and demand
(via mode switch)
Output
Output options
• relay output (DPDT), 2 floating
SPDTs
• contactless electronic switch
• 2 wire Namur signal output
Measuring Accuracy
Repeatability
0.1 mm (0.004 inch)
Hysteresis
approx. 2 mm (0.08 inch) with
vertical installation
Switching delay
approx. 500 ms (on/off)
Frequency
approx. 1200 Hz
Rated operating conditions
5
Installation conditions
• Location
Ambient conditions
• Ambient temperature
• Installation category
• Pollution degree
Medium conditions
• Temperature
- LVL200S Standard
- LVL200S High temperature
option
- LVL200E Standard: with
316L/Hastelloy
- LVL200E High temperature
option: with 316L/Hastelloy
• Pressure (vessel)
• Density
Design
• Material
• Enclosure
• Contactless
Indoor/outdoor
-40 ... +70 °C (-40 ... +158 °F)
III
2
-50 ... +150 °C (-58 ... +302 °F)
-50 ... +250 °C (-58 ... +482 °F)
• 2-wire Namur
IEC 60947-5-6, approx. 8.2 V
Off-load voltage Uo approx. 8.2 V
Short-circuit current IU approx.
8.2 mA
Power consumption
• Relay DPDT
• Contactless
1 ... 8 VA (AC), approx. 1.3 W (DC)
1 ... 8 VA (AC), approx. 1.3 W (DC)
Domestic current requirement
approx. 3 mA (via load circuit)
-50 ... +250 °C (-58 ... +482 °F)
• Extension tube [ø 21.3 mm
(0.839 inch)]
• Process connection: threaded
• Process connection: flange
• Process seal
Process connection
• Pipe thread, cylindrical
(ISO 228 T1)
• Pipe thread, tapered
• Flanges
• Hygienic fittings
Siemens FI 01 · 2012
Aluminum die-cast AISi10Mg,
powder-coated, basis: Polyester
316L (1.4404 or 1.4435),
Hastelloy
316L (1.4404 or 1.4435),
Hastelloy
316L (1.4404 or 1.4435),
Hastelloy
316L (1.4404 or 1.4435), 316L
with Hastelloy, ECTFE, or PFA
coating
Klingersil C-4400
G ¾" A, G 1" A
¾" NPT, 1" NPT, 1½" NPT
DIN from DN25, ANSI from 1"
Bolting DN40 PN40, 1, 1½, 2,
2½" Tri-Clamp PN 10, conus
DN25 PN 40, Tuchenhagen
Varivent DN50 PN10, SMS
20 ... 253 V AC, 50/60 Hz,
20 ... 72 V DC [at U>60 V DC
20 ... 253 V AC, 50/60 Hz,
20 ... 253 V DC
Operating voltage (characteristics
according to standard) for connection to an amplifier according to
NAMUR
-50 ... +150 °C (-58 ... +302 °F)
-1 ... 64 bar g (-14.5 ... 928 psi g)
0.7 ... 2.5 g/cm³
(0.025 ... 0.09 lbs/in³);
0.5 ... 2.5 g/cm³
(0.018 ... 0.09 lbs/in³)
by switching over
approx. 0.8 ... 4 kg
(0.18 ... 8.82 lb)
approx 920 g/m
(10 oz/ft)
Power supply
Supply voltage
• Relay DPDT
• 2-wire Namur
Certificates and approvals
• Tuning fork
5/88
Weight
• Device weight
(dependent on process fitting)
• Tube extension
(extended version)
Type 4X/NEMA 4X/IP66/IP67
• 1 x M20x1.5 (cable: ø5 to 9 mm),
1 x blind stopper M20x1.5;
attached 1 x M20x1.5 cable
entry
• 1 x ½" NPT cable entry,
1 x blind stopper ½"NPT,
1 x ½" NPT
cable entry
• 1x M12x1;
1 x blind stopper M20x1.5
Load current
- Min. 10 mA
- Max. 400 mA [with I > 300 mA
the ambient temperature can
be max. +60 °C (+140 °F)]
- Max. 4 A up to 40 ms
(not WHG specified)
Current consumption
- falling characteristics ≥ 2.6 mA
uncovered/≤ 0.6 mA covered
- ≤ 0.6 mA uncovered/≥ 2.6 mA
covered
- failure message ≤ 0.6 mA
• CE, CSA
• Overfill Protection WHG
and VLAREM II
• FM (Non-Incendive) Class I,
Div. 2, Groups A, B, C, D
• FM (Explosion-Proof) Class I, Div.
1, Groups A, B, C, D; (Dust Ignition-Proof) Class II, III, Div. 1,
Groups E, F, G1)
• IECEx d IIC T6...T2 Ga/Gb EHEDG
• ATEX II 1/2G, 2G EEx d IIC T6
• ATEX II 1G, 1/2G,
2G EEx ia IIC T6
Shipping approvals: ABS, DNV,
LR, RINA, GL, CCS
• BR-Ex d IIC T6...T2
• FDA, 3A, Ehedge
• SIL/IEC61508 Declaration of Conformity [SIL-2
(min/max detection)]
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
Electronics
Contactless electronic switch 20...250 V AC/DC
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC
NAMUR signal1)
Approvals
Without approvals
Overfill protection (WHG)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG2)
WHG3)
77 7 77 - 77 A 0
1
2
4
A
B
C
ATEX II 1/2G, 2G EEx d IIC T6 +
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping
approvals2)
ATEX II 1/2G, 2G EEx d IIC T6 + shipping approvals3)
D
E
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2 D
IP6X T2)
G
IECEx Ex ia IIC T6
Shipping approvals
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP)
Class II, III, Div. 1, Groups E, F, G3)4)
H
K
P
FM (NI) Class I, Div. 2, Groups A, B, C, D4)
IECEx d IIC T6...T2 Ga/Gb
CSA(XP)CL I,II,III DIV 1,GP A B C D E F G
Q
R
S
CSA(NI)CL I,II,III, DIV 2,GP A B C D E F G
IECEx d IIC T6...T2 Ga/Gb
T
U
F
Process connection
Thread G¾" A, PN64/316L
Thread G¾" A, PN64/316L Ra < 0.8 µm
Thread ¾" NPT, PN64/316L
A00
A01
A02
Thread ¾" NPT, PN64/316L Ra < 0.8 µm
Thread ¾" NPT, PN64/Monel
Thread G¾" A, PN64/Hastelloy
A03
A04
A05
Thread ¾" NPT, PN64/Hastelloy
Thread G1" A, PN64/316L
Thread G1" A, PN64/316L ECTFE coated MB19825)
A06
A07
A08
Thread G1" A, PN64/316L PFA coated5)
Thread G1" A, PN64/Monel
Thread G1" A, PN64/316L Ra < 0.8 µm
A10
A11
A13
Thread 1" NPT, PN64/316L
Thread 1" NPT, PN64/316L ECTFE coated
MB19825)
Thread 1" NPT, PN64/316L PFA-coated5)
A14
A15
Thread 1" NPT, PN64/Monel
Thread 1" NPT, PN64/316L Ra < 0.8 µm
A17
A18
Thread G1" A, PN64/Hastelloy
Thread G1½" A, PN64/316L
Thread G1½" A, PN64/316L Ra<0,8µm
A20
A21
A22
A16
Thread G1½" A, PN64/Hastelloy
Thread 1" NPT, PN64/Hastelloy
Thread 1½" NPT, PN64/316L
A23
A24
A25
Thread 1½" NPT, PN64/316L Ra<0,8µm
Thread 1½" NPT, PN64/Hastelloy
Thread G2" A, PN64/316L
A26
A27
A28
Thread M27x1.5, PN64/316L
Conus DN25, PN40/316L Ra < 0.3 µm
Conus DN25, PN40/316L Ra < 0.8 µm
A30
A31
A32
(ZB3033)5)
Conus DN25, PN40/ECTFE
Conus M52, PN40/316L
Conus M52, PN40/316L Ra < 0.3 µm
A33
A34
A35
Conus M52, PN40/316L Ra < 0.8 µm
Tri-Clamp 1", PN16/316L Ra < 0.3 µm
Tri-Clamp 1", PN16/Hastelloy
A36
A37
A38
7 7 7 77 - 77 A 0
Tri-Clamp 1", PN16/316L Ra < 0.8 µm
Tri-Clamp 1½", PN16/316L Ra < 0.3 µm
A40
A4 1
Tri-Clamp 1½", PN16/Hastelloy
A42
Tri-Clamp 1½", PN16/316L Ra < 0.8 µm
Tri-Clamp 2", PN16/316L Ra < 0.3 µm
Tri-Clamp 2", PN16/Hastelloy
A43
A44
A45
Tri-Clamp 2", PN16/316L Ra < 0.8 µm
Tri-Clamp 2½", PN10/316L Ra < 0.3 µm
Tri-Clamp 2½", PN10/316L Ra < 0.8 µm
A46
A47
A48
Tri-Clamp 3", PN10/316L Ra < 0.3 µm
Tri-Clamp 3", PN10/316L Ra < 0.8 µm
Bolting DN32, PN40 DIN11851/316L Ra < 0.3 µm
A50
A51
A52
Bolting DN32, PN40 DIN11851/316L Ra < 0.8 µm
Bolting DN25, PN40 DIN11851/316L Ra < 0.3 µm
Bolting DN25, PN40 DIN11851/316L Ra < 0.8 µm
A53
A54
A55
Bolting DN40, PN40 DIN11851/316L Ra < 0.3 µm
Bolting DN40, PN40 DIN11851/316L Ra < 0.8 µm
Bolting DN 40, PN40 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A56
A57
A58
Bolting DN50, PN25 DIN11851/316L Ra < 0.3 µm
Bolting DN50, PN25 DIN11851/316L Ra < 0.8 µm
Bolting DN50, PN25 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A60
A61
A62
Hygienic w. compr. nut F40, PN25/316L
Hygienic w. compr. nut F40, PN25/316L
Ra < 0.3 µm
Hygienic w. compr. nut F40, PN25/316L
Ra < 0.8 µm
A63
A64
Varivent N50-40/316L Ra < 0.3 µm
Varivent N50-40/316L Ra < 0.8 µm
Varivent N125/100/316L Ra < 0.8 µm
A66
A67
A68
DRD flange, PN40/316L ZB3007
SMS DN38/316L Ra < 0.8 µm5)
SMS DN51, PN6/316L Ra < 0.8 µm5)
A70
A71
A72
Swagelok VCR screwing ZG2579, PN64/316L
Neumo biocontrol Gr. 25, PN16/316L Ra < 0.8 µm
Neumo biocontrol Gr. 50, PN16/316L Ra < 0.8 µm5)
A73
A74
A75
Neumo biocontrol Gr. 65, PN16/316L Ra < 0.8 µm
Neumo biocontrol Gr. 80, PN16/316L Ra < 0.8 µm
SÜDMO DN50, PN10/316L Ra<0,8µm
A76
A77
A78
Small flange DN25, PN1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Small flange DN40, PN1.5 DIN 28403/316L pol.
Ra < 0.8 µm
Ingold connection, PN16/316L Ra < 0.8 µm
A80
Ingold connection, PN16/Hastelloy
Terminal DN 33,7 PN40 DIN11864-3-A-/316L BN2
Ra < 0.8 µm5)
Hygienic fl. DN50 PN16 DIN11864-2-A-/316L
Ra < 0.8 µm
A83
A84
Flange DN25, PN6 Form C, DIN 2501/316L
Flange DN25, PN6 Form C, DIN 2501/PFA5)
Flange DN25, PN40 Form C, DIN 2501/316L
A86
A87
A88
Flange DN25, PN40 Form C, DIN 2501/Hastelloy
Flange DN25, PN40 Form C, DIN 2501/ECTFE5)
Flange DN25, PN40 Form C, DIN 2501/PFA5)
B00
B01
B02
Flange DN25, PN40 Form C, DIN 2501/Enamelled
Flange DN25, PN40 Form D, DIN 2501/316L
Flange DN25, PN40 Form F, DIN 2501/316L
B03
B04
B05
Flange DN25, PN40 Form N, DIN 2501/316L
Flange DN25, PN40 Form N, DIN 2501/Hastelloy
Flange DN25, PN40 Form N, DIN 2501/Monel solid
B06
B07
B08
5
A65
A81
A82
A85
Siemens FI 01 · 2012
5/89
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
5
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
77 7 77 - 77 A 0
7 7 7 77 - 77 A 0
Flange DN100, PN40 Form C, DIN 2501/ECTFE5)
Flange DN100, PN40 Form C, DIN 2501/PFA5)
Flange DN100, PN40 Form C,
DIN 2501/Enamelled6)
B72
B73
B74
Flange DN100, PN40 Form F, DIN 2501/316L
Flange DN100, PN40 Form N, DIN 2501/316L
Flange DN100, PN40 V13, DIN 2501/316L
B75
B76
B77
Flange DN100, PN64 Form E, DIN 2501/316L
Flange DN100, PN100 Form E, DIN 2501/316L
Flange DN100, PN100 Form L, DIN 2501/316L
B78
B80
B81
Flange DN125, PN16 Form F, DIN 2501/316L
Flange DN125, PN40 Form C, DIN 2501/316L
Flange DN125, PN40 Form N, DIN 2512/ 316L
B82
B83
B84
Flange DN150, PN16 Form C, DIN 2501/316L
Flange DN150, PN16 Form C, DIN 2501/Hastelloy
Flange DN150, PN16 Form C, DIN 2501/ECTFE5)
B85
B86
B87
Flange DN150, PN16 Form C, DIN 2501/PFA5)
Flange DN150, PN16 Form D, DIN 2501/316L
Flange DN150, PN40 Form C, DIN 2501/316L
B88
C00
C01
B30
B31
B32
Flange DN150, PN40 Form C, DIN 2501/Hastelloy
Flange DN150, PN40 Form F, DIN 2501/316L
Flange DN150, PN40 Form N, DIN 2512/316L
C02
C03
C04
Flange DN50, PN40 Form F, DIN 2501/316L
Flange DN50, PN40 Form N, DIN 2501/316L
Flange DN50, PN40 Form N, DIN 2501/Hastelloy
B33
B34
B35
Flange DN200, PN10 Form C, DIN 2501/ECTFE5)
Flange DN200, PN16 Form C, DIN 2501/316L
Flange DN25, PN40 Form B1, EN 1092-1/316L
C05
C06
C07
Flange DN50, PN40 Form E, DIN 2501/316L
Flange DN50, PN40 V13, DIN 2501/316L
Flange DN50, PN40 R13, DIN 2501/316L
B36
B37
B38
C08
C10
C11
Flange DN50, PN64 Form F, DIN 2501/316L
Flange DN50, PN64 Form N, DIN 2501/Hastelloy
Flange DN50, PN64 Form C, DIN 2501/316L
B40
B41
B42
Flange DN25, PN40 Form B1, EN 1092-1/Hastelloy
Flange DN25, PN40 Form B1, EN/ 316L/ PFA5)
Flange DN25, PN40 Form B1, EN 1092-1/
Enamelled 6)
Flange DN50, PN64 Form L, DIN 2501/316L
Flange DN50, PN100 Form E, DIN 2501/316L
Flange DN50, PN100 Form L, DIN 2501/316L
B43
B44
B45
Flange DN25, PN40 Form B2, EN 1092-1/316L
Flange DN25, PN40 Form F, EN 1092-1/316L
Flange DN25, PN63 Form B1, EN 1092-1/316L
C12
C13
C14
Flange DN25, PN100 Form B2, EN 1092-1/316L
Flange DN40, PN40 Form B1, EN/ 316L
Flange DN40, PN40 Form B1, EN 1092-1/PFA5)
C15
C16
C17
Flange DN65, PN40 Form C, DIN 2501/316L
Flange DN65, PN40 Form C, DIN 2501/Hastelloy
Flange DN65, PN40 Form C, DIN 2501/ECTFE5)
B46
B47
B48
Flange DN40, PN40 Form B2, EN/316L
Flange DN50, PN40 Form B1, EN/316L
Flange DN50, PN40 Form B1, EN 1092-1/Hastelloy
C18
C20
C21
Flange DN65, PN40 Form C, DIN 2501/PFA5)
Flange DN65, PN40 Form F, DIN 2501/316L
Flange DN65, PN64 Form E, DIN 2501/316L
B50
B51
B52
C22
Flange DN80, PN40 Form C, DIN 2501/316L
Flange DN80, PN40 Form C, DIN 2501/
Hastelloy
Flange DN80, PN40 Form C, DIN 2501/ECTFE5)
B53
B54
Flange DN50, PN40 Form B1, EN 1092-1/
Monel ZB2977
Flange DN50, PN40 Form B1, EN 1092-1/ECTFE5)
Flange DN50, PN40 Form B1, EN/ 316L/PFA5)
C25
Flange DN80, PN40 Form C, DIN 2501/PFA5)
Flange DN80, PN40 Form C, DIN 2501/Enamelled6)
Flange DN80, PN40 Form F, DIN 2501/316L
Flange DN50, PN40 Form B1, EN 1092-1/
Enamelled6)
Flange DN50, PN40 Form C, EN 1092-1/316L
Flange DN50, PN40 Form D, EN/316L
B56
B57
B58
Flange DN50, PN40 Form D, EN 1092-1/Hastelloy
Flange DN50, PN40 Form B2, EN 1092-1/316L
Flange DN50, PN40 Form E, EN 1092-1/316L
C28
C30
C31
Flange DN80, PN40 Form N, DIN 2501/316L
Flange DN80, PN40 Form N, DIN 2501/Hastelloy
Flange DN100, PN16 Form C, DIN 2501/316L
B60
B61
B62
Flange DN80, PN40 Form B1, EN 1092-1/316L
Flange DN80, PN40 Form B1, EN 1092-1/Hastelloy
Flange DN80, PN40 Form B1, EN 1092-1/ECTFE5)
C32
C33
C34
Flange DN100, PN16 Form C, DIN 2501/Hastelloy
Flange DN100, PN16 Form C, DIN 2501/ECTFE5)
Flange DN100, PN16 Form C, DIN 2501/PFA5)
B63
B64
B65
C35
Flange DN100, PN16 Form C,
DIN 2501/Enamelled6)
Flange DN100, PN16 Form D, DIN 2501/316L
Flange DN100, PN16 Form F, DIN 2501/316L
B66
Flange DN80, PN40 Form B1, EN 1092-1/
Enamelled6)
Flange DN80, PN40 Form B2, EN 1092-1/316L
Flange DN100, PN16 Form B1, EN 1092-1/316L
C38
Flange DN100, PN16 Form N, DIN 2501/316L
Flange DN100, PN40 Form C, DIN 2501/316L
B70
B71
Flange DN100, PN16 Form B1, EN 1092-1/
Hastelloy
Flange DN100, PN16 Form B1, EN 1092-1/
Enamelled6)
Flange DN100, PN40 Form B1, EN 1092-1/316L
Flange DN25, PN40 V13, DIN 2501/316L
Flange DN32, PN40 Form C, DIN 2501/316L
Flange DN32, PN40 Form C, DIN 2501/ECTFE5)
B10
B11
B12
Flange DN40, PN6 Form C, DIN 2501/316L
Flange DN40, PN6 Form C, DIN 2501/ECTFE5)
Flange DN40, PN40 Form C, DIN 2501/316L
B13
B14
B15
Flange DN40, PN40 Form C, DIN 2501/Hastelloy
Flange DN40, PN40 Form C, DIN 2501/ECTFE5)
Flange DN40, PN40 Form C, DIN 2501/PFA5)
B16
B17
B18
Flange DN40, PN40 Form C, DIN 2501/Enamelled6)
Flange DN40, PN40 Form F, DIN 2501/316L
Flange DN40, PN40 Form N, DIN 2501/316L
B20
B21
B22
Flange DN40, PN40 Form E, DIN 2501/316L
Flange DN40, PN40 V13, DIN 2501/316L
Flange DN50, PN40 Form C, DIN 2501/316L
B23
B24
B25
Flange DN50, PN40 Form C, DIN 2501/Hastelloy
Flange DN50, PN40 Form C, DIN 2501/ECTFE5)
Flange DN50, PN40 Form C, DIN 2501/
ECTFE (ZB3108)5)
B26
B27
B28
Flange DN50, PN40 Form C, DIN 2501/PFA5)
Flange DN50, PN40 Form D, DIN 2501/316L
Flange DN50, PN40 Form D, DIN 2501/Hastelloy
5/90
Siemens FI 01 · 2012
B55
B67
B68
C23
C24
C26
C27
C36
C37
C40
C41
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
77 7 77 - 77 A 0
7 7 7 77 - 77 A 0
Flange DN100, PN40 Form B1, EN 1092-1/
Enamelled6)
C42
Flange 3" 150lb RF, ANSI B16.5/PFA5)
Flange 3" 150lb RF, ANSI B16.5/Enamelled6)
D15
D16
Flange DN100, PN40 Form C, EN 1092-1/316L
Flange DN100, PN63 Form B2, EN 1092-1/316L
C43
C44
Flange 3" 150lb FF, ANSI B16.5/316L
D17
Flange DN150, PN16 Form B1, EN 1092-1/316L
C45
Flange DN150, PN16 Form B1, EN 1092-1/PFA5)
Flange DN150, PN40 Form B1, EN 1092-1/316L
C46
C47
Flange 3" 150lb FF, ANSI B16.5/ECTFE5)
Flange 3" 150lb FF, ANSI B16.5/PFA5)
Flange 3" 300lb RF, ANSI B16.5/316L
D18
D20
D21
Flange DN150, PN40 Form B1, EN 1092-1/ECTFE5)
Flange DN150, PN40 Form B2, EN 1092-1/316L
Flange 1" 150lb ANSI B16.5/316L
C48
C50
C51
Flange 3" 300lb RF, ANSI B16.5/Hastelloy
Flange 3" 300lb RF, ANSI B16.5/ECTFE5)
Flange 3" 300lb RF, ANSI B16.5/PFA5)
D22
D23
D24
Flange 1" 150lb RF, ANSI B16.5/Hastelloy
Flange 1" 150lb RF, ANSI B16.5/Monel ZB2977
Flange 1" 150lb RF, ANSI B16.5/ECTFE5)
C52
C53
C54
Flange 3" 300lb RF, ANSI B16.5/Enameled6)
Flange 3" 600lb RF, ANSI B16.5/316L
Flange 3½" 150lb RF, ANSI B16.5/316L
D25
D26
D27
Flange 3½" 150lb RF, ANSI B16.5/ECTFE5)
Flange 4" 150lb RF, ANSI B16.5/316L
Flange 4" 150lb RF, ANSI B16.5/Hastelloy
D28
D30
D31
Flange 4" 150lb RF, ANSI B16.5/ECTFE5)
Flange 4" 150lb RF, ANSI B16.5/PFA5)
Flange 4" 150lb RF, ANSI B16.5/Enamelled6)
D32
D33
D34
Flange 4" 150lb LT, ANSI B16.5/316L
Flange 4" 300lb RF, ANSI B16.5/316L
Flange 4" 300lb RF, ANSI B16.5/Hastelloy
D35
D36
D37
Flange 4" 300lb RF, ANSI B16.5/ECTFE5)
Flange 4" 300lb RJF, ANSI B16.5/316L
Flange 4" 300lb LG, ANSI B16.5/316L
D38
D40
D41
Flange 4" 300lb LT, ANSI B16.5/316L
Flange 4" 600lb RF, ANSI B16.5/316L
Flange 4" 600lb RJF, ANSI B16.5/316L
D42
D43
D44
Flange 6" 150lb RF, ANSI B16.5/316L
Flange 6" 150lb RF, ANSI B16.5/Hastelloy
Flange 6" 150lb RF, ANSI B16.5/ECTFE5)
D45
D46
D47
Flange 6" 150lb RF, ANSI B16.5/PFA5)
Flange 6" 150lb RJF, ANSI B16.5/316L
Flange 6" 300lb RF, ANSI B16.5/316L
D48
D50
D51
Flange 8" 150lb RF, ANSI B16.5/316L
Flange 8" 150lb RF, ANSI B16.5/ECTFE5)
Flange 1" BS.10 Table E/316L
D52
D53
D54
Flange 1" BS.10 Table E/PFA5)
Flange 1½" BS.10 Table E/316L
Flange 3½" BS.10 Table E/316L
D55
D56
D57
Flange 4" BS.10 Table E/ECTFE5)
Flange DN40 10K, JIS/316L
Flange DN50 10K, JIS/316L
D58
D60
D61
Flange DN80 10K, JIS/316L
Flange DN100 10K, JIS/316L
D62
D63
B16.5/PFA5)
Flange 1" 150lb RF, ANSI
Flange 1" 150lb RF, ANSI B16.5/Enamelled6)
Flange 1" 300lb RF, ANSI B16.5/316L
B16.5/ECTFE5)
C55
C56
C57
Flange 1"300lb RF, ANSI
Flange 1" 600lb RF, ANSI B16.5/316L
Flange 1½" 150lb RF, ANSI B16.5/316L
C58
C60
C61
Flange 1½" 150lb RF, ANSI B16.5/Hastelloy
Flange 1½" 150lb RF, ANSI B16.5/ECTFE5)
Flange 1½" 150lb RF, ANSI B16.5/PFA5)
C62
C63
C64
Enamelled6)
Flange 1½" 150lb RF, ANSI B16.5
Flange 1½" 150lb FF, ANSI B16.5/ECTFE5)
Flange 1½" 300lb RF, ANSI B16.5/316L
C65
C66
C67
Flange 1½" 300lb RF, ANSI B16.5/Monel ZB2977
Flange 1½" 300lb RF, ANSI B16.5/ECTFE6)
Flange 1½" 600lb RF, ANSI B16.5/316L
C68
C70
C71
Flange 2" 150lb RF, ANSI B16.5/316L
Flange 2" 150lb RF, ANSI B16.5/Hastelloy
Flange 2" 150lb RF, ANSI B16.5/Monel ZB2977
C72
C73
C74
Flange 2" 150lb RF, ANSI B16.5/ECTFE5)
Flange 2" 150lb RF, ANSI B16.5/PFA5)
Flange 2" 150lb RF, ANSI B16.5/Enamelled6)
C75
C76
C77
Flange 2" 150lb FF, ANSI B16.5/316L
Flange 2" 150lb FF, ANSI B16.5/ECTF5)
Flange 2" 150lb SG (small groove), ANSI
B16.5/316L
C78
C80
C81
Flange 2" 300lb RF, ANSI B16.5/316L
Flange 2" 300lb RF, ANSI B16.5/Hastelloy
Flange 2" 300lb RF, ANSI B16.5/Hastelloy
C82
C83
C84
Flange 2" 300lb RF, ANSI B16.5/ECTFE5)
Flange 2" 300lb RF, ANSI B16.5/PFA5)
Flange 2" 300lb RF, ANSI B16.5 Enamelled6)
C85
C86
C87
Flange 2" 300lb RJF, ANSI B16.5/316L
Flange 2" 300lb ST, ANSI B16.5/316L
Flange 2" 300lb LG (large groove),
ANSI B16.5/316L
C88
D00
D01
Flange 2" 300lb LT, ANSI B16.5/316L
Flange 2" 600lb RF, ANSI B16.5/316L
Flange 2" 600lb RF, ANSI B16.5/Monel ZB2977
D02
D03
D04
Flange 2" 600lb RF, ANSI B16.5/ECTFE5)
Flange 2" 600lb RJF, ANSI B16.5/316L
Flange 2" 600lb LG, ANSI B16.5/316L
D05
D06
D07
Flange 2" 900lb RJF, ANSI B16.5/316L
Flange 2½" 150lb RF, ANSI B16.5/316L
Flange 2½" 300lb RF, ANSI B16.5/316L
D08
D10
D11
Flange 3" 150lb RF, ANSI B16.5/316L
Flange 3" 150lb RF, ANSI B16.5/Hastelloy
Flange 3" 150lb RF, ANSI B16.5/ECTFE5)
D12
D13
D14
Adapter/Process temperature
Without adapter/-50 ... +150 °C (-58 ... +302 °F)
With adapter/-50 ... +200 °C (-58 ... +392 °F)7)
With adapter/-50 .... +250 °C (-58 ... +482 °F)
With gas-tight leadthrough/-50 ... +150 °C
(-58 ... +302 °F)
With gas-tight leadthrough/-50 ... +250 °C
(-58 ... +482 °F)
Siemens FI 01 · 2012
5
1
2
3
4
5
5/91
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
SITRANS LVL200, Standard
Compact vibrating level switch for use in liquid and
slurry applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5746-
Further designs
77 7 77 - 77 A 0
Please add "-Z" to Order No. and specify Order
code(s).
Housing/ Cable entry
Aluminium IP66/IP67/M20x1.5
Aluminium IP66/IP67/½" NPT
1)
2)
3)
4)
5)
6)
7)
A
B
Available with Approval options A to G, and K, and Adapter/Process temperature options 1, and 3 to 5 only
Available with Electronics option 4 only
Available with Adapter/Process temperature options 1 and 3 only
Available with Housing/Cable entry option B only
Available with Adapter/Process temperature options 1 and 4 only
Available with Adapter/Process temperature options 1, 2, and 4 only
Available with enamelled Process connection options only
5
Order code
Cleaning including Certificate
(oil, grease and silicone free)
W01
Identification Label (measurement loop) SS:
max. 16 characters add in plain text
Y17
Identification Label (measurement loop) Foil:
max. 16 characters add in plain text
Y18
Acceptance test certificate 3.1 NACE MR 0775 for
material EN10204
D07
Acceptance test certificate 3.1 for instrument
EN10204
C12
Acceptance test certificate 2.2 for instrument
EN10204
C14
Acceptance test Certificate 2.2 for material
EN10204
C15
SIL/IEC61508 Certificate of conformity
(SIL-2 min. and max. detection)
C20
Additional Operating Instructions
Order No.
LVL200 (DPDT Relay)
• English
7ML1998-5KR01
• French
7ML1998-5KR11
• Spanish
7ML1998-5KR21
• German
7ML1998-5KR31
LVL200 (Contactless electronic switch)
• English
7ML1998-5KQ01
• French
7ML1998-5KQ11
• Spanish
7ML1998-5KQ21
• German
7ML1998-5KQ31
Electronics module LVL200 Relay
• English
7ML1998-5LS01
• French
7ML1998-5LS11
• Spanish
7ML1998-5LS21
• German
This device is shipped with the Siemens Milltronics
manual CD containing the complete Operating
Instructions library.
7ML1998-5LS31
Spare Parts and Accessories
5/92
Siemens FI 01 · 2012
Electronics module SITRANS LVL200 Relay
LVL100 Threaded Welded Socket
7ML1830-1NC
• G ¾" A / 316L with FKM Seal
7ML1930-1EE
• G 1 A / 316L with FKM Seal
7ML1930-1EF
• M27x1.5 / 316L with FKM Seal
7ML1930-1EG
• G ¾ A / 316L with EPDM Seal
7ML1930-1EH
• G 1 A / 316L with EPDM Seal
7ML1930-1EJ
• M27x1.5 / 316L with EPDM Seal
7ML1930-1EK
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
7 7 7 77 - 777 7
Electronics
Contactless electronic switch 20...250 V AC/DC
Double relay (DPDT) 20 ... 72 V DC/20 ... 250 V AC
NAMUR signal1)
1
2
4
Approvals
77 7 77 - 777 7
Tri-Clamp 1" PN16/Hastelloy
Tri-Clamp 1" PN16/316L Ra < 0.8 µm
A40
A41
Tri-Clamp 1½" PN16/316L Ra < 0.3 µm
Tri-Clamp 1½" PN16/Hastelloy
Tri-Clamp 1½" PN16/316L Ra < 0.8 µm
A42
A43
A44
Without approvals
Overfill protection (WHG)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + WHG2)
A
B
C
Tri-Clamp 2" PN16/316L Ra < 0.3 µm
Tri-Clamp 2" PN16/Hastelloy
Tri-Clamp 2" PN16/316L Ra < 0.8 µm
A45
A46
A47
ATEX II 1/2G, 2G EEx d IIC T6 + WHG3)4)
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + shipping
approvals2)
ATEX II 1/2G, 2G EEx d IIC T6 + shipping
approvals3)4)
D
E
Tri-Clamp 2½" PN10/316L Ra < 0.3 µm
Tri-Clamp 2½" PN10/316L Ra < 0.8 µm
Tri-Clamp 3" PN10/316L Ra < 0.3 µm
A48
A50
A51
F
Tri-Clamp 3" PN10/316L Ra < 0.8 µm
A52
ATEX II 1G, 1/2G, 2G EEx ia IIC T6 + ATEX II 1/2D
IP6X T2)
G
Bolting DN32 PN40 DIN11851/316L Ra < 0.3 µm
Bolting DN32 PN40 DIN11851/316L Ra < 0.8 µm
Bolting DN25 PN40 DIN11851/316L Ra < 0.3 µm
A53
A54
A55
IECEx Ex ia IIC T6
Shipping approvals
FM (XP) Class I, Div. 1, Groups A, B, C, D; (DIP)
Class II, III, Div. 1, Groups E, F, G3)4)5)
H
K
P
Bolting DN25 PN40 DIN11851/316L Ra < 0.8 µm
Bolting DN40 PN40 DIN11851/316L Ra < 0.3 µm
Bolting DN40 PN40 DIN11851/316L Ra < 0.8 µm
A56
A57
A58
FM (NI) Class I, Div. 2, Groups A, B, C, D5)
IECEx d IIC T6...T2 Ga/Gb4)
CSA(XP)CL I,II,III DIV 1,GP A B C D E F G...T2 Ga/Gb 4)
Q
R
S
Bolting DN40 PN40 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
Bolting DN50 PN25 DIN11851/316L Ra < 0.3 µm
Bolting DN50 PN25 DIN11851/316L Ra < 0.8 µm
A60
CSA(NI)CL I,II,III, DIV 2,GP A B C D E F G
IECEx d IIC T6...T2 Ga/Gb4)
T
U
Bolting DN50 PN25 DIN11864-1 A/316L
Ra < 0.8 µm ZB3052
A63
Hygienic w.compr.nut F40 PN25/316L
Hygienic w.compr.nut F40 PN25/316L Ra < 0.3 µm
Hygienic w.compr.nut F40 PN25/316L Ra < 0.8 µm
A64
A65
A66
Varivent N50-40/316L Ra < 0.3 µm
Varivent N50-40/316L Ra < 0.8 µm
Varivent N125/100/316L Ra < 0.8 µm
A67
A68
A70
DRD flange PN40/316L ZB3007
SMS DN38/316L Ra < 0.8 µm6)
SMS DN51 PN6/316L Ra < 0.8 µm6)
A71
A72
A73
Swagelok VCR screwing ZG2579 PN64/316L
Neumo biocontrol Gr.25 PN16/316L Ra < 0.8 µm
Neumo biocontrol Gr.50 PN16/316L Ra < 0.8 µm
A74
A75
A76
Neumo biocontrol Gr.65 PN16/316L Ra < 0.8 µm
Neumo biocontrol Gr.80 PN16/316L Ra < 0.8 µm
SÜDMO DN50 PN10/316L Ra < 0.8 µm
A77
A78
A80
Small flange DN25 PN1.5 DIN 28403/316L
pol.Ra < 0.8 µm
Small flange DN40 PN1.5 DIN 28403/316L
pol.Ra < 0.8 µm
Ingold connection PN16/316L Ra < 0.8 µm
A81
Terminal DN33.7 PN40 DIN 11864-3-A-/316L BN2
Ra < 0.8 µm
A84
Hygienic fl. DN50 PN16 DIN 11864-2-A-/316L
Ra < 0.8 µm
A85
Flange DN25 PN6 Form C, DIN 2501/316L
Flange DN25 PN6 Form C, DIN 2501/PFA6)
Flange DN25 PN40 Form C, DIN 2501/316L
A86
A87
A88
Flange DN25 PN40 Form C, DIN 2501/Hastelloy
B00
Flange DN25 PN40 Form C, DIN 2501/ECTFE6)
Flange DN25 PN40 Form C, DIN 2501/PFA6)
Flange DN25 PN40 Form D, DIN 2501/316L
B01
B02
B03
Process connection
Thread G¾" A, PN64/316L
Thread G¾" A, PN64/316L Ra < 0.8 µm
Thread ¾" NPT, PN64/316L
A00
A01
A02
Thread ¾" NPT, PN64/316L Ra < 0.8 µm
Thread ¾" NPT, PN64/Monel
Thread G¾" A, PN64/Hastelloy
A03
A04
A05
Thread ¾" NPT, PN64/Hastelloy
Thread G1" A, PN64/316L
Thread G1" A, PN64/316L ECTFE coated MB19826)
A06
A07
A08
coated6)
Thread G1" A, PN64/316L PFA
Thread G1" A, PN64/Monel
Thread G1" A, PN64/316L Ra < 0.8 µm
A10
A11
A13
Thread 1" NPT, PN64/316L
Thread 1" NPT, PN64/316L ECTFE coated MB19826)
Thread 1" NPT, PN64/316L PFA coated6)
A14
A15
A16
Thread 1" NPT, PN64/Monel
Thread 1" NPT, PN64/316L Ra < 0.8 µm
Thread G1" A, PN64/Hastelloy
A17
A18
A20
Thread G1½" A, PN64/316L
Thread G1½" A, PN64/316L Ra <0.8 µm
Thread G1½" A, PN64/Hastelloy
A21
A22
A23
Thread 1" NPT, PN64/Hastelloy
Thread 1½" NPT, PN64/316L
Thread 1½" NPT, PN64/316L Ra< 0.8 µm
A24
A25
A26
Thread 1½" NPT, PN64/Hastelloy
Thread G2" A, PN64/316L
Thread M27x1.5 PN64/316L
A27
A28
A30
Cyl. socket/316Ti/1.4581 ECTFE coated ZB29846)
Conus DN25 PN40/316L Ra < 0.3 µm
Conus DN25 PN40/316L Ra < 0.8 µm.
A31
A32
A33
Conus DN25 PN40/ECTFE (ZB3033)6)
Conus M52 PN40/316L
Conus M52 PN40/316L Ra < 0.3 µm
A34
A35
A36
Conus M52 PN40/316L Ra < 0.8 µm
A37
Tri-Clamp 1" PN16/316L Ra < 0.3 µm
A38
5
A61
A62
A82
A83
Siemens FI 01 · 2012
5/93
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
5
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
7 7 7 77 - 777 7
77 7 77 - 777 7
Flange DN25 PN40 Form F, DIN 2501/316L
Flange DN25 PN40 Form N, DIN 2501/316L
Flange DN25 PN40 Form N, DIN 2501/Hastelloy
B04
B05
B06
Flange DN100 PN40 Form C, DIN 2501/316L
Flange DN100 PN40 Form C, DIN 2501/ECTFE6)
Flange DN100 PN40 Form C, DIN 2501/PFA6)
B67
B68
B70
Flange DN25 PN40 Form N, DIN 2501/Monel solid
Flange DN25 PN40 V13, DIN 2501/316L
B07
B08
B71
Flange DN32 PN40 Form C, DIN 2501/316L
B10
Flange DN100 PN40 Form C, DIN 2501/
Enamelled7)
Flange DN100 PN40 Form F, DIN 2501/316L
Flange DN100 PN40 Form N, DIN 2501/316L
Flange DN32 PN40 Form C, DIN 2501/ECTFE6)
Flange DN40 PN6 Form C, DIN 2501/316L
Flange DN40 PN6 Form C, DIN 2501/ECTFE6)
B11
B12
B13
Flange DN100 PN40 V13, DIN 2501/316L
Flange DN100 PN64 Form E, DIN 2501/316L
Flange DN100 PN100 Form E, DIN 2501/316L
B74
B75
B76
Flange DN40 PN40 Form C, DIN 2501/316L
Flange DN40 PN40 Form C, DIN 2501/Hastelloy
Flange DN40 PN40 Form C, DIN 2501/ECTFE6)
B14
B15
B16
Flange DN100 PN100 Form L, DIN 2501/316L
Flange DN125 PN16 Form F, DIN 2501/316L
Flange DN125 PN40 Form C, DIN 2501/316L
B77
B78
B80
Flange DN40 PN40 Form C, DIN 2501/PFA6)
Flange DN40 PN40 Form C, DIN 2501/Enamelled7)
Flange DN40 PN40 Form F, DIN 2501/316L
B17
B18
B20
Flange DN125 PN40 Form N, DIN 2512/316L
Flange DN150 PN16 Form C, DIN 2501/316L
Flange DN150 PN16 Form C, DIN 2501/Hastelloy
B81
B82
B83
Flange DN40 PN40 Form N, DIN 2501/316L
Flange DN40 PN40 Form E, DIN 2501/316L
Flange DN40 PN40 V13, DIN 2501/316L
B21
B22
B23
Flange DN150 PN16 Form C, DIN 2501/ECTFE6)
Flange DN150 PN16 Form C, DIN 2501/PFA6)
Flange DN150 PN16 Form D, DIN 2501/316L
B84
B85
B86
Flange DN50 PN40 Form C, DIN 2501/316L
Flange DN50 PN40 Form C, DIN 2501/Hastelloy
Flange DN50 PN40 Form C, DIN 2501/ECTFE6)
B24
B25
B26
Flange DN150 PN40 Form C, DIN 2501/316L
Flange DN150 PN40 Form C, DIN 2501/Hastelloy
Flange DN150 PN40 Form F, DIN 2501/316L
B87
B88
C00
Flange DN50 PN40 Form C, DIN 2501/ECTFE
(ZB3108)6)
Flange DN50 PN40 Form C, DIN 2501/PFA6)
Flange DN50 PN40 Form D, DIN 2501/316L
B27
Flange DN150 PN40 Form N, DIN 2512/316L
Flange DN200 PN10 Form C, DIN 2501/ECTFE6)
Flange DN200 PN16 Form C, DIN 2501/316L
C01
C02
C03
Flange DN50 PN40 Form D, DIN 2501/Hastelloy
Flange DN50 PN40 Form F, DIN 2501/316L
Flange DN50 PN40 Form N, DIN 2501/316L
B31
B32
B33
Flange DN25 PN40 Form B1, EN 1092-1/316L
Flange DN25 PN40 Form B1, EN 1092-1/Hastelloy
Flange DN25 PN40 Form B1, EN/316L/PFA6)
C04
C05
C06
Flange DN50 PN40 Form N, DIN 2501/Hastelloy
Flange DN50 PN40 Form E, DIN 2501/316L
Flange DN50 PN40 V13, DIN 2501/316L
B34
B35
B36
Flange DN25 PN40 Form B1, EN 1092-1/
Enamelled7)
Flange DN25 PN40 Form B2, EN 1092-1/316L
Flange DN25 PN40 Form F, EN 1092-1/316L
C07
Flange DN50 PN40 R13, DIN 2501/316L
Flange DN50 PN64 Form F, DIN 2501/316L
Flange DN50 PN64 Form N, DIN 2501/Hastelloy
B37
B38
B40
Flange DN25 PN63 Form B1, EN 1092-1/316L
Flange DN25 PN100 Form B2, EN 1092-1/316L
Flange DN40 PN40 Form B1, EN/316L
C11
C12
C13
Flange DN50 PN64 Form C, DIN 2501/316L
Flange DN50 PN64 Form L, DIN 2501/316L
Flange DN50 PN100 Form E, DIN 2501/316L
B41
B42
B43
Flange DN40 PN40 Form B1, EN 1092-1/PFA6)
Flange DN40 PN40 Form B2, EN/316L
Flange DN50 PN40 Form B1, EN/316L
C14
C15
C16
Flange DN50 PN100 Form L, DIN 2501/316L
Flange DN65 PN40 Form C, DIN 2501/316L
Flange DN65 PN40 Form C, DIN 2501/Hastelloy
B44
B45
B46
C17
C18
Flange DN65 PN40 Form C, DIN 2501/ECTFE6)
Flange DN65 PN40 Form C, DIN 2501/PFA6)
Flange DN65 PN40 Form F, DIN 2501/316L
B47
B48
B50
Flange DN50 PN40 Form B1, EN 1092-1/Hastelloy
Flange DN50 PN40 Form B1,EN 1092-1/
Monel ZB2977
Flange DN50 PN40 Form B1, EN 1092-1/ECTFE6)
C21
C22
Flange DN65 PN64 Form E, DIN 2501/316L
Flange DN80 PN40 Form C, DIN 2501/316L
Flange DN80 PN40 Form C, DIN 2501/Hastelloy
B51
B52
B53
Flange DN50 PN40 Form B1, EN/316L/PFA6)
Flange DN50 PN40 Form B1, EN 1092-1/
Enamelled7)
Flange DN50 PN40 Form C, EN 1092-1/316L
Flange DN80 PN40 Form C, DIN 2501/ECTFE6)
Flange DN80 PN40 Form C, DIN 2501/PFA6)
Flange DN80 PN40 Form F, DIN 2501/316L
B54
B55
B56
Flange DN50 PN40 Form D, EN/316L
Flange DN50 PN40 Form D, EN 1092-1/
Hastelloy
Flange DN50 PN40 Form B2, EN 1092-1/316L
C24
C25
Flange DN50 PN40 Form E, EN 1092-1/316L
Flange DN80 PN40 Form B1, EN 1092-1/316L
Flange DN80 PN40 Form B1, EN 1092-1/Hastelloy
C27
C28
C30
Flange DN80 PN40 Form B1, EN 1092-1/ECTFE6)
Flange DN80 PN40 Form B1, EN 1092-1/
Enamelled7)
Flange DN80 PN40 Form B2, EN 1092-1/316L
C31
C32
Flange DN100 PN16 Form B1, EN 1092-1/316L
Flange DN100 PN16 Form B1, EN 1092-1/Hastelloy
Flange DN100 PN16 Form B1, EN 1092-1/
Enamelled7)
C34
C35
C36
B28
B30
Flange DN80 PN40 Form N, DIN 2501/316L
Flange DN80 PN40 Form N, DIN 2501/Hastelloy
Flange DN100 PN16 Form C, DIN 2501/316L
B57
B58
B60
Flange DN100 PN16 Form C, DIN 2501/Hastelloy
Flange DN100 PN16 Form C, DIN 2501/ECTFE6)
Flange DN100 PN16 Form C, DIN 2501/PFA6)
B61
B62
B63
Flange DN100 PN16 Form D, DIN 2501/316L
Flange DN100 PN16 Form F, DIN 2501/316L
Flange DN100 PN16 Form N, DIN 2501/316L
B64
B65
B66
5/94
Siemens FI 01 · 2012
B72
B73
C08
C10
C20
C23
C26
C33
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
7 7 7 77 - 777 7
77 7 77 - 777 7
Flange DN100 PN40 Form B1, EN 1092-1/316L
Flange DN100 PN40 Form B1, EN 1092-1/
Enamelled7)
Flange DN100 PN40 Form C, EN 1092-1/316L
C37
C38
Flange 3" 150lb RF, ANSI B16.5//Monel ZB2977
Flange 3" 150lb RF, ANSI B16.5/ECTFE6)
Flange 3" 150lb RF, ANSI B16.5/PFA6)
D11
D12
D13
C40
Flange DN100 PN63 Form B2, EN 1092-1/316L
Flange DN150 PN16 Form B1, EN 1092-1/316L
Flange DN150 PN16 Form B1, EN 1092-1/PFA6)
C41
C42
C43
Flange 3" 150lb RF, ANSI B16.5/Enamelled7)
Flange 3" 150lb FF, ANSI B16.5/316L
Flange 3" 150lb FF, ANSI B16.5/ECTFE6)
D14
D15
D16
Flange DN150 PN40 Form B1, EN 1092-1/316L
Flange DN150 PN40 Form B1, EN 1092-1/ECTFE6)
C44
C45
Flange 3" 150lb FF, ANSI B16.5/PFA6)
Flange 3" 300lb RF, ANSI B16.5/316L
Flange 3" 300lb RF, ANSI B16.5/Hastelloy
D17
D18
D20
Flange DN150 PN40 Form B2, EN 1092-1/316L
C46
Flange 1" 150lb ANSI B16.5/316L
Flange 1"150lb RF, ANSI B16.5/Hastelloy
Flange 1"150lb RF, ANSI B16.5//Monel ZB2977
C47
C48
C50
Flange 3" 300lb RF, ANSI B16.5/ECTFE6)
Flange 3" 300lb RF, ANSI B16.5/PFA6)
Flange 3" 300lb RF, ANSI B16.5/Enamelled7)
D21
D22
D23
Flange 3" 600lb RF, ANSI B16.5/316L
Flange 3½" 150lb RF, ANSI B16.5/316L
Flange 3½" 150lb RF, ANSI B16.5/ECTFE6)
D24
D25
D26
Flange 4" 150lb RF, ANSI B16.5/316L
Flange 4" 150lb RF, ANSI B16.5/Hastelloy
Flange 4" 150lb RF, ANSI B16.5/ECTFE6)
D27
D28
D30
Flange 4" 150lb RF, ANSI B16.5/PFA6)
Flange 4" 150lb RF, ANSI B16.5/Enamelled7)
Flange 4" 150lb LT, ANSI B16.5/316L
D31
D32
D33
Flange 4" 300lb RF, ANSI B16.5/316L
Flange 4" 300lb RF, ANSI B16.5/Hastelloy
Flange 4" 300lb RF, ANSI B16.5/ECTFE6)
D34
D35
D36
Flange 4" 300lb RJF, ANSI B16.5/316L
Flange 4" 300lb LG, ANSI B16.5/316L
Flange 4" 300lb LT, ANSI B16.5/316L
D37
D38
D40
Flange 4" 600lb RF, ANSI B16.5/316L
Flange 4" 600lb RJF, ANSI B16.5/316L
Flange 5" 150lb RF, ANSI B16.5/316L
D41
D42
D43
Flange 6" 150lb RF, ANSI B16.5/316L
Flange 6" 150lb RF, ANSI B16.5/Hastelloy
Flange 6" 150lb RF, ANSI B16.5/ECTFE6)
D44
D45
D46
Flange 6" 150lb RF, ANSI B16.5/PFA6)
Flange 6" 150lb RJF, ANSI B16.5/316L
Flange 6" 300lb RF, ANSI B16.5/316L
D47
D48
D50
Flange 8" 150lb RF, ANSI B16.5/316L
Flange 8" 150lb RF, ANSI B16.5/ECTFE6)
Flange 1" BS.10 Table E/316L
D51
D52
D53
Flange 1" BS.10 Table E/PFA6)
Flange 1½" BS.10 Table E/316L
Flange 3½" BS.10 Table E/316L
D54
D55
D56
Flange 4" BS.10 Table E/ECTFE6)
Flange DN40 10K, JIS/316L
Flange DN50 10K, JIS/316L
D57
D58
D60
Flange DN80 10K, JIS/316L
Flange DN100 10K, JIS/316L
D61
D62
B16.5/ECTFE6)
Flange 1" 150lb RF, ANSI
Flange 1"150lb RF, ANSI B16.5/PFA6)
Flange 1" 150lb RF, ANSI B16.5/Enamelled7)
C51
C52
C53
Flange 1" 300lb RF, ANSI B16.5/316L
Flange 1" 300lb RF, ANSI B16.5/ECTFE6)
C54
C55
Flange 1" 600lb RF, ANSI B16.5/316L
C56
Flange 1½" 150lb RF, ANSI B16.5/316L
Flange 1½" 150lb RF, ANSI B16.5/Hastelloy
Flange 1½" 150lb RF, ANSI B16.5/ECTFE6)
C57
C58
C60
Flange 1½" 150lb RF, ANSI B16.5/PFA6)
Flange 1½" 150lb RF, ANSI B16.5 Enamelled7)
Flange 1½" 150lb FF, ANSI B16.5/ECTFE6)
C61
C62
C63
Flange 1½" 300lb RF, ANSI B16.5/316L
Flange 1½" 300lb RF, ANSI B16.5//Monel ZB2977
Flange 1½" 300lb RF, ANSI B16.5/ECTFE6)
C64
C65
C66
Flange 1½" 600lb RF, ANSI B16.5/316L
Flange 2" 150lb RF, ANSI B16.5/316L
Flange 2" 150lb RF, ANSI B16.5/Hastelloy
C67
C68
C70
Flange 2" 150lb RF, ANSI B16.5//Monel ZB2977
Flange 2" 150lb RF, ANSI B16.5/ECTFE6)
Flange 2" 150lb RF, ANSI B16.5/PFA6)
C71
C72
C73
Flange 2" 150lb RF, ANSI B16.5/Enamelled7)
Flange 2" 150lb FF, ANSI B16.5/316L
Flange 2" 150lb FF, ANSI B16.5/ECTFE6)
C74
C75
C76
Flange 2" 150lb SG (small groove),
ANSI B16.5/316L
Flange 2" 300lb RF, ANSI B16.5/316L
Flange 2" 300lb RF, ANSI B16.5/Hastelloy
C77
Flange 2" 300lb RF, ANSI B16.5/Hastelloy
Flange 2" 300lb RF, ANSI B16.5/ECTFE6)
Flange 2" 300lb RF, ANSI B16.5/PFA6)
C81
C82
C83
Flange 2" 300lb RF, ANSI B16.5 Enamelled7)
Flange 2" 300lb RJF, ANSI B16.5/316L
Flange 2" 300lb ST, ANSI B16.5/316L
C84
C85
C86
Flange 2" 300lb LG (large groove),
ANSI B16.5/316L
Flange 2" 300lb LT, ANSI B16.5/316L
Flange 2" 600lb RF, ANSI B16.5/316L
C87
Flange 2" 600lb RF, ANSI B16.5/Monel ZB2977
Flange 2" 600lb RF, ANSI B16.5/ECTFE6)
Flange 2" 600lb RJF, ANSI B16.5/316L
D01
D02
D03
Flange 2" 600lb LG, ANSI B16.5/316L
Flange 2" 900lb RJF, ANSI B16.5/316L
Flange 2½" 150lb RF, ANSI B16.5/316L
D04
D05
D06
Flange 2½" 300lb RF, ANSI B16.5/316L
Flange 3" 150lb RF, ANSI B16.5/316L
Flange 3" 150lb RF, ANSI B16.5/Hastelloy
D07
D08
D10
C78
C80
5
C88
D00
Siemens FI 01 · 2012
5/95
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
SITRANS LVL200, Rigid extension
Compact vibrating level switch for use in liquid
applications such as overflow, high, low, and
demand applications, as well as pump protection.
For use in SIL-2 and hazardous applications.
7ML5747-
7 7 7 77 - 777 7
Rigid Extension Enamelled version7)
Adapter/Process temperature
Without adapter/-50 ... 150 °C
With adapter/-50 ... 200 °C8)
With adapter/-50... 250 °C
1
2
3
80 ... 250 mm
251 ... 500 mm
501 ... 750 mm
F0
F1
F2
With gas-tight leadthrough/-50 ... +150 °C
With gas-tight leadthrough/-50 ... +250 °C
4
5
751 ... 1000 mm
1001 ... 1250 mm
1251 ... 1500 mm
F3
F4
F5
Housing/ Cable entry
Aluminium IP66/IP67/M20x1.5
Aluminium IP66/IP67/½" NPT
Rigid Extension Hastelloy
A
B
NOTE:
When selecting a Rigid Extension option,
extension coating must match the process
connection coating and the material and
surface roughness type.
Rigid Extension 316L
5
77 7 77 - 777 7
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
A0
A1
A2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
A3
A4
A5
3001 ... 3500 mm
3501 ... 4000 mm
A6
A7
Rigid Extension ECTFE coated6)
B0
B1
B2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
B3
B4
B5
3001 ... 3500 mm
3501 ... 4000 mm
B6
B7
Rigid Extension PFA coated6)
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
C0
C1
C2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
C3
C4
C5
Rigid Extension 316L Ra ≤ 0.8 μm
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
D0
D1
D2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
D3
D4
D5
3001 ... 3500 mm
3501 ... 4000 mm
D6
D7
Rigid Extension 316L Ra ≤ 0.3 μm
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
E0
E1
E2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
E3
E4
E5
3001 ... 3500 mm
3501 ... 4000 mm
E6
E7
Siemens FI 01 · 2012
G0
G1
G2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
G3
G4
G5
3001 ... 3500 mm
3501 ... 4000 mm
G6
G7
Rigid Extension Monel
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
H0
H1
H2
1501 ... 2000 mm
2001 ... 2500 mm
2501 ... 3000 mm
H3
H4
H5
1)
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
5/96
80 ... 500 mm
501 ... 1000 mm
1001 ... 1500 mm
2)
3)
4)
5)
6)
7)
8)
Available with Approval options A to G, and K, and Adapter/Process temperature options 1, and 3 to 5 only
Available with Electronics option 4 only
Available with Adapter/Process temperature options 1 and 3 only
Extension length restricted to 2956 mm
Available with Housing/Cable entry option B only
Available with Adapter/Process temperature options 1 and 4 only
Available with Adapter/Process temperature options 1, 2, and 4 only
Available with enamelled Process connection and Extension options only
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Cleaning including Certificate
(oil, grease and silicone free)
W01
Enter the total insertion length in plain text description, max. 4000 mm (157.48 inch)
Y01
Identification Label (measurement loop) SS:
max. 16 characters add in plain text
Y17
Identification Label (measurement loop) Foil:
max. 16 characters add in plain text
Y18
Acceptance test certificate 3.1 NACE MR 0775 for
material EN10204
D07
Acceptance test certificate 3.1 for instrument
C12
Acceptance test certificate 2.2 for instrument
C14
Acceptance test Certificate 2.2 for material
EN10204
C15
SIL/IEC61508 Certificate of conformity
(SIL-2/3 min. and max. detection)
C20
Additional Operating Instructions
Order No.
5
LVL200 Extended (DPDT Relay)
• English
7ML1998-5KW01
• French
7ML1998-5KW11
• Spanish
7ML1998-5KW21
• German
7ML1998-5KW31
LVL200 (Contactless electronic switch)
• English
7ML1998-5KV01
• French
7ML1998-5KV11
• Spanish
7ML1998-5KV21
• German
7ML1998-5KV31
Electronics module LVL200 Relay
• English
7ML1998-5LS01
• French
7ML1998-5LS11
• Spanish
7ML1998-5LS21
• German
This device is shipped with the Siemens Milltronics
manual CD containing the complete Operating
Instructions library.
7ML1998-5LS31
Spare Parts and Accessories
Electronics module SITRANS LVL200 Relay
7ML1830-1NC
Lock fitting, unpressurized, G1A/316L
7ML1930-1DQ
Lock fitting, unpressurized, 1NPT/316L
7ML1930-1DR
Lock fitting, unpressurized, G1-1/2A/316L
7ML1930-1DS
Lock fitting, unpressurized, 1-1/2NPT/316LL
7ML1930-1DT
Lock fitting, -1… 16 bar, G1A/316L
7ML1930-1DU
Lock fitting, -1… 16 bar, 1NPT/316L
7ML1930-1DV
Lock fitting, -1… 16 bar, G1-1/2A/316L
7ML1930-1DW
Lock fitting, -1… 16 bar, 1-1/2NPT/316L
7ML1930-1DX
Lock fitting, -1… 64 bar, G1A/316L
7ML1930-1EA
Lock fitting, -1… 64 bar, 1NPT/316L
7ML1930-1EB
Lock fitting, -1… 64 bar, G1-1/2A/316L
7ML1930-1EC
Lock fitting, -1… 64 bar, 1-1/2NPT/316L
7ML1930-1ED
Siemens FI 01 · 2012
5/97
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Options
LVL200 Threaded Welded Socket
G¾" A/316L
Lock fitting
39 (1.54)
G1"
32
(1.26)
29,5
(1.16)
32 (1.26)
G¾"
53 (2.09)
5
LVL200 Extended
64 bar
G1" A/316L
60 (2.36)
SITRANS LVL200 welded socket and lock fitting, dimensions in mm (inch)
5/98
Siemens FI 01 · 2012
LVL200 Extended
16 bar
LVL200 Extended
Unpressurized
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Characteristic curves
Ambient temperature in °C (°F)
Ambient/Process temperature
Temperature range with
temperature adapter
70 ºC
(158 ºF)
40 ºC
(104 ºF)
-50 ºC
(-58 ºF)
0 ºC
(32 ºF) 0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
-40 ºC
(-40 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
Process pressure in bar (psi g)
Process pressure with switch position 0.7 g/cm³ (mode switch)
-50 ºC
(-58 ºF)
5
64
(928)
40
(580)
20
(290)
-1
(-14.5)
0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
Process pressure in bar (psi g)
Process pressure with switch position 0.5 g/cm³ (mode switch)
-50 ºC
(-58 ºF)
64
(928)
40
(580)
20
(290)
-1
(-14.5)
0 ºC
(32 ºF)
50 ºC
(122 ºF)
100 ºC
(212 ºF)
150 ºC
(302 ºF)
200 ºC
(392 ºF)
250 ºC
(482 ºF)
Process temperature in °C (°F)
SITRANS LVL200 Process Pressure/Process Temperature/Ambient Temperature derating curves
Siemens FI 01 · 2012
5/99
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Dimensional drawings
SITRANS LVL200 (Standard)
~116 (4.57)
Ø84 (3.31)
125 (4.92)
M20 x 1,5
M20 x 1,5 or
½" NPT
Cone DN25
Bolting DN40
Temperature adapter
34
(1.34)
53
(2.09)
50
(1.97)
Ø33.7 (1.33)
SITRANS LVL200 (Standard), dimensions in mm (inch)
5/100
Siemens FI 01 · 2012
178 (7.01)
57
(2.24)
Gas-tight leadthrough
19
(0.75)
Flange
55
(2.17)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
36
53 (2.09) (1.42)
66
(2.60)
SW 32
(G ¾" A, ¾" NPT)
SW 41
(G 1" A, 1" NPT)
53
(2.09)
5
Tri-Clamp
18,5
(0.73)
Threaded
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
SITRANS LVL200 (Extended)
Sensor length (L)
~ 116
(4.57)
Ø 84
(3.31)
M20 x 1.5
316L, Hastelloy C4 (2.4610)
80 ... 6000 mm (3.15 ... 236.2”)
Hastelloy C4 (2.4610) enamelled
80 ... 1500 mm (3.15 ... 59.06”)
316L, ECTFE coated
80 ... 3000 mm (3.15 ... 118.1”)
316L, PFA coated
80 ... 3000 mm (3.15 ... 118.1”)
125
(4.92)
M20 x 1.5 or
½" NPT
Threaded
18.5
(0.73)
Tri-clamp
32 (G ¾" A, ¾" NPT)
41 (G 1" A, 1" NPT)
36
(1.42)
Cone DN25
5
57
(2.24)
G ¾" A, ¾" NPT
G 1" A, 1" NPT
Temperature adapter
L
L
Bolting DN40
Flanged
L
Gas-tight leadthrough
178
(7.01)
19
(0.75)
50
(1.97)
34
(1.34)
L
L
SITRANS LVL200 (Extended), dimensions in mm (inch)
Siemens FI 01 · 2012
5/101
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVL200
■ Schematics
1
Relay (DPDT)
+ –
L1 N
2
20 to 72 V DC
20 to 253 V AC
3
1
2
3
4
5
6
7
8
6
4
Relay
output
Relay
output
Voltage
supply
Contactless
5
1
N
NAMUR
(IEC 60947-5-6)
+ Simul.
6
1
max.
2
min.
5
2
L1 N
AC + –
DC – +
3
1 2
4
Voltage
supply
1
Control lamp
2
DIL switch for characteristics reversal
3
DIL switch for sensitivity adjustment
4
Ground terminal
5
Simulation key
6
Connection terminals
SITRANS LVL200 connections
5/102
Siemens FI 01 · 2012
NAMUR
+
–
1
2
+
–
Amplifier according to NAMUR
IEC 60947-5-6, approx. 8.2 V
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS100
■ Overview
■ Configuration
Installation
Rigid extension with
sliding sleeve
Position tines vertically to
avoid product build-up:
use a 50 mm open-end
wrench to turn the process
connection until the tine
orientation marking faces up
or down.
L
*
Protection in case of high
material loading.
O
Cable gland faces
downward to avoid
water penetration.
SITRANS LVS100 is a vibrating point level switch for bulk solids.
■ Benefits
Tine orientation marking
facing sideways.
• High resistance to mechanical forces
• Sliding sleeve options for adjustable insertion length and ease
of cleaning
• Rotatable enclosure for ease of installation and wiring
• Suitable for point level detection of materials starting at a bulk
density of 60 g/l (3.8 lb/ft3)
• Customer desired extensions up to 2000 mm (78.74 inch)
Use angle mounting for
flowing material only. If angle
mounting is required with high
material loading, customersupplied protection from
falling material must be in
place.
■ Application
SITRANS LVS100 detects high, low, or demand levels of dry bulk
solids in bins, silos or hoppers.
*
SITRANS LVS100 has a compact design and can be top, side,
or angle mounted. The vibrating fork design ensures the tines
are kept clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become
damaged.
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material, the
change in vibration is detected by the electronic circuitry which
causes the relay to change state after a one second delay. When
the fork is free from material pressure, full vibration resumes and
the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers
max. deviation
from vertical O
max. length L
5°
4.0 m
45°
1.2 m
> 45°
0.6 m
SITRANS LVS100 installation
Siemens FI 01 · 2012
5/103
5
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS100
■ Technical specifications
Mode of Operation
Measuring principle
Design
Vibrating point level switch
Material
• Enclosure
Input
Measured variable
High, low, and demand
Measuring frequency
200 Hz
Process connection
Output
Relays
DPDT relay
Relay delay
From loss of vibration:
approximately 1 second
From resumption of vibration:
approximately 1 to 2 seconds
Signal delay
Probe uncovered to covered:
approximately 1 second
Tine material
Stainless steel 316TI (1.4571)
Degree of protection
IP66/Type 4/NEMA 4
High or low, switch selectable
Conduit entry
2 x M20x1.5 or 2 x ½" NPT
Relay 8 A at 250 V AC,
non-inductive
Weight
Standard version, no extensions:
approx 1.7 kg (3.7 lb)
Relay 5 A at 30 V DC,
non-inductive
Power supply
• 19 ... 230 V AC, +10%,
50 ... 60 Hz, 8 VA
• 19 ... 50 V DC, +10%, 1.5 W
Certificates and approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• C-TICK
• ATEX II 1/2 D
Probe covered to uncovered:
approximately 1 to 2 seconds
Relay fail-safe
Alarm output
5
High or low, switch selectable
Sensitivity
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
-40 ... +60 °C (-40 ... +140 °F)
• Installation catagory
III
• Pollution degree
2
Medium conditions
• Process temperature
-40 ... +150 °C (-40 ... +302 °F)
• Max. threaded bushing temperature
+80 °C (+176 °F)
• Max. enclosure surface temperature (Category 2D)
+90 °C (+194 °F)
• Max. extension surface temperature (Category 1D)
+150 °C (+302 °F)
• Pressure (vessel)
Max. 10 bar g (145 psi g)
European Pressure Directive
97/23/EC: Category 1
Minimum material density
approx. 60 g/l (3.8 lb/ft3)
5/104
Siemens FI 01 · 2012
Epoxy coated aluminum
• Thread 1¼" NPT [(Taper),
ANSI/ASME B1.20.1],
R 1½" [(BSPT), EN 10226]
• Thread R 1½" [(BSPT),
EN 10226], ½" NPT [(Taper),
ANSI/ASME B1.20.1], sliding
sleeve
[min. length 500 mm
(19.69 inch)]
• Thread material:
stainless steel 304 (1.4301) or
316TI (1.4571) depending on
configuration
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS100
Selection and Ordering data
Order No.
SITRANS LVS100, standard
Vibrating point level switch for high or low level
detection of bulk solids. Sensitivity > 60 g/l.
7ML5735-
1½" NPT [(Taper), ANSI/ASME B1.20.1] ,
sliding sleeve [min. length 500 mm (19.69 inch)]
60
(2.36)
75 (2.95)
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226] DIN 2999 thread,
sliding sleeve - min. length 500 mm (19.69 inch)
1
A
A
B
C
60
(2.36)
D
120 (4.72)
Tine orientation
marking
Extension length
Stainless steel 316TI (1.4571)
Standard length, 170 mm (6.69 inch)
11
Add order code Y01 and plain text:
"Insertion length ... mm"
Stainless steel 304 (1.4301)
• 300 ... 500 mm (11.81 ... 19.69 inch)
• 501 ... 1000 mm (19.72 ... 39.37 inch)
12
13
• 1001 ... 1500 mm (39.41 ... 59.06 inch)
• 1501 ... 2000 mm (59.09 ... 78.74 inch)
14
15
Approvals
CSA/FM General Purpose, CE, C-TICK
CSA/FM Class II, Div. 1, Group E,F, G, Class III,
ATEX II 1/2 D, C-TICK
150 (5.91)
Process temperature
Up to +150 °C (+302 °F)
7 7 7 77 - 07A 0
Threaded bushing
[max. temp.
+80 °C (+176 °F)]
Zone 21
(Cat. 2)
Customer supplied
process flange
A
B
125 (4.92):
standard fork
Tine
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. 2000 mm
(78.74 inch)
Y01
Signal bulb inserted in M20 cable gland
A20
Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FT63
SITRANS LVS100, dimensions in mm (inch)
Spare Parts
Replacement Electronics Module LVS100 DPDT
5
Zone 20
(Cat. 1)
170 to 2000 (6.69 to 78.74):
Customer specified rigid
Input Voltage
DPDT Relay - 19 ... 230 V AC, 19 ... 50 V DC
■ Dimensional drawings
7ML1830-1NS
■ Schematics
Universal voltage (DPDT relay)
Alarm
output
relay
FSH/FSL
adjustment
Relay (19 to 253 V AC, 19 to 55 V DC)
R 1½ " [(BSPT), EN 10226] DIN 2999 thread,
sliding sleeve
7ML1830-1NT
1½" NPT [(Taper), ANSI/ASME B1.20.1] ,
sliding sleeve [min. length 500 mm (19.69 inch)]
7ML1830-1NU
Sensitivity adjustment:
B = factory setting,
A = decreased
876 543
LED
21
AC: Terminal 1: L
Terminal 2: N
19 to 230 V AC, +10%, 50 to 60 Hz, 8 VA
DC: Terminal 1: +
Terminal 2: 19 to 50 V DC, +10%, 2 W
SITRANS LVS100 connections
Siemens FI 01 · 2012
5/105
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
■ Overview
■ Application
The standard LVS200 detects high, low, or demand levels of dry
bulk solids in bins, silos, or hoppers. The liquid/solid interface
version can also detect settled solids within liquids or solids
within confined spaces such as feed pipes. It is designed to
ignore liquids in order to detect the interface between a solid
and a liquid.
A pipe extension version is available with either the standard or
liquid/solid interface electronics and fork, separated by a customer supplied 1" pipe.
SITRANS LVS200 has an optional 4 to 20 mA output for monitoring buildup on the fork to determine when preventative maintenance should be performed in sticky applications.
The LVS200 has a compact design and can be top, side or angle
mounted. The vibrating fork design ensures the tines are kept
clean. The unique design of the fork and crystal assembly eliminates false high level readings even if tines become damaged.
SITRANS LVS200 is a vibrating point level switch for high, low, or
demand level detection of bulk solids.
5
■ Benefits
•
•
•
•
High resistance to mechanical forces
Strong vibration resistance to high bulk material loads
Rotatable enclosure for convenient wiring
Suitable for low density material: standard version, 20 g/l
(1.3 lb/ft3); liquid/solid interface version, 50 g/l (3 lb/ft3),
and low density option min. 5 g/l (0.3 lb/ft3)
• Customer desired extensions up to 20000 mm (787 inch)
• Optional detection of solids within liquid
• Durable short fork option with 165 mm (6.5 inch) insertion
length
5/106
Siemens FI 01 · 2012
A signal from the electronic circuit excites a crystal in the probe
causing the fork to vibrate. If the fork is covered by material, the
change in vibration is detected by the electronic circuitry which
causes the relay to change state after a one second delay. When
the fork is free from material pressure, full vibration resumes and
the relay reverts to its normal condition.
• Key Applications: dry bulk solids in bins, silos, hoppers or settled solids within liquids (interface version)
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
■ Technical specifications
Mode of operation
Measuring principle
Vibrating point level switch
Medium conditions
• Process temperature
Input
Measured variable
High, low, and demand
Measuring frequency
• Standard
• Liquid/solid interface and short
fork version
125 Hz
350 Hz
Output
PNP
2-wire without contact
Relays
• Version with 1 relay
• Version with 2 relays
Open collector:
Permanent load max. 0.4 A,
short-circuit and overload
protected
Turn-on voltage: max. 50 V
(reverse protection)
Load current:
• min. 10 mA
• max. 500 mA permanent
• max. 2A < 200 ms
• max. 5A < 50 ms
Voltage drop on the electronic
module: max. 7 V with closed
electric circuit
Cutoff current with open electric
circuit: max. 5 mA
• Max. threaded bushing temperature
• Max. enclosure surface temperature (Category 2D)
• Max. extension surface temperature (Category 1D)
• Pressure (vessel)
• Minimum material density
• All except CSA Class II,
Group G:
-40 ... +150 °C (-40 ... +302 °F)
• CSA Class II, Group G:
-40... +140 °C (-40 ... +284 °F),
CSA temperature code T3B
+80 °C (+176 °F)
+90 °C (+194 °F)
+150 °C (+302 °F)
Max. 10 bar g (145 psi g)
European Pressure Directive
97/23/EC: Category 1
• Standard version: approx. 20 g/l
(1.2 lb/ft3)
• liquid/solid interface version:
approx. 50 g/l (3 lb/ft3)
• optional low density version:
approx. 5 g/l (0.3 lb/ft3)
Design
Material
• Enclosure
5
Epoxy coated aluminum
Process connection
• Thread 1½" NPT [(Taper),
ANSI/ASME B1.20.1], R ½"
[(BSPT), EN 10226] and flange
options
• Optional sliding bushing with
2" NPT [(Taper), ANSI/ASME
B1.20.1] or BSP thread
• Thread material: stainless steel
303 (1.4301)
SPDT relay
DPDT relay
Relay delay
• From loss of vibration:
approximately 1 second
• From resumption of vibration:
approximately 1 to 2 seconds
Tine material
Signal delay
• Probe uncovered to covered:
approximately 1 second
• Probe covered to
uncovered: approximately
1 to 2 seconds
Stainless steel 316TI (1.4571),
PTFE-coated tines are available
upon special request
Degree of protection
IP65/Type 4/NEMA 4
Conduit entry
Relay fail-safe
High or low, switch selectable
Weight
Alarm output
• Relay 8 A at 250 V AC,
non-inductive
• Relay 5 A at 30 V DC,
non-inductive
2 x M20x1.5 or 2 x ½" NPT
• Standard version, no extensions: approx 2.0 kg (4.4 lb)
• Solids/liquids version, no extensions: approx. 1.9 kg (4.2 lb)
mA output
• Resolution
8/16 mA or 4 ... 20 mA
4 to 20 mA ± 0.1 mA
Sensitivity
High or low, switch selectable
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation catagory
• Pollution degree
-40 ... +60 °C (-40 ... +140 °F)
III
2
Power supply
• 19 ... 230 V AC, +10%,
50 ... 60 Hz, 8 VA
• 19 ... 55 V DC, +10%, 1.5 W
Certificates and approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• C-TICK
• ATEX II 1/2 D
• CSA/FM IS Class I, II, III Div. 1,
Groups A, B, C, D, E, F, G, FM
Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, available only with
power supply option 5 and 6
• ATEX II 1G and 1/2 G Eex ia IIC;
ATEX II 1D and 1/2 D, available
only with power supply option 5
Siemens FI 01 · 2012
5/107
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
SITRANS LVS200, standard
SITRANS LVS200 is a vibrating point level switch
for high, low, or demand level detection of bulk
solids.
7ML5731-
7 7 7 7 7 - 77 A 0
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
5
Stainless Steel 316TI (1.4571)
Standard length, 235 mm (9.25 inch)9)
2
Add order code Y01 and plain text:
"Insertion length ... mm"
3
4
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire3)
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT) basic version4) 5)
1
5
6
} 7
Process temperature
Without temperature isolator
}
With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process +150 °C(+302 °F)/
max. temperature electronics +80 °C (+176 °F)]
A
B
C
D
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process+150 °C (+302 °F)/
max. temperature electronics +80 °C (+176 °F)]
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]6)
}
}
D
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
G
H
J
Tri-clamp 2" Stainless steel 304 (1.4301)7)
K
Extension length
Stainless steel 304 (1.4301)
Standard length, 235 mm (9.25 inch)8)
E
F
36
37
38
2001 ... 2250 mm (78.78 ... 88.58 inch)9)
2251 ... 2500 mm (88.62 ... 98.43 inch)9)
2501 ... 2750 mm (98.46 ... 108.27 inch)9)
2751 ... 3000 mm (108.31 ... 118.11 inch)9)
41
42
43
44
3001 ... 3250 mm (118.15 ... 127.95 inch)9)
3251 ... 3500 mm (127.99 ... 137.80 inch)9)
3501 ... 3750 mm (137.83 ... 147.64 inch)9)
3751 ... 4000 mm (147.68 ... 157.48 inch)9)
45
46
47
48
}
}
11
• 1001 ... 1250 mm (39.41 ... 49.21 inch)8)
• 1251 ... 1500 mm (49.25 ... 59.06 inch)8)
• 1501 ... 1750 mm (59.09 ... 68.90 inch)8)
15
16
17
• 1751 ... 2000 mm (68.94 ... 78.74 inch)8)
• 2001 ... 2250 mm (78.78 ... 88.58 inch)8)
• 2251 ... 2500 mm (88.62 ... 98.43 inch)8)
18
21
22
• 2501 ... 2750 mm (98.46 ... 108.27 inch)8)
• 2751 ... 3000 mm (108.31 ... 118.11 inch)8)
• 3001 ... 3250 mm (118.15 ... 127.95 inch)8)
23
24
25
• 3251 ... 3500 mm (127.99 ... 137.80 inch)8)
• 3501 ... 3750 mm (137.83 ... 147.64 inch)8)
• 3751 ... 4000 mm (147.68 ... 157.48 inch)8)
26
27
28
1
2
A
B
C
D
E
F
Available with approval options A to D only
Available with approval options E and F only
3) Available with approval option D only
4)
Available only with process temperature option A (process connection A
with approval option B, or process connection B with approval option A),
extension length 11 and material process connection 1
5)
Basic version is cost effective and offers fast delivery
6) Not available with extension length options 11 and 12
7)
Available with approval options B, C, D, and F only
8)
Available with Material process connection/extension option 1 only
9) Available with Material process connection/extension option 2 only
10)
Available with power supply option 5 and 6 only
2)
12
13
14
Siemens FI 01 · 2012
1251 ... 1500 mm (49.25 ... 59.06 inch)9)
1501 ... 1750 mm (59.09 ... 68.90 inch)9)
1751 ... 2000 mm (68.94 ... 78.74 inch)9)
1)
Add order code Y01 and plain text:
"Insertion length ... mm"
• 300 ... 500 mm (11.81 ... 19.69 inch)8)
• 501 ... 750 mm (19.72 ... 29.53 inch)8)
• 751 ... 1000 mm (29.57 ... 39.37 inch)8)
5/108
32
33
34
35
Approvals
CSA/FM Dust Ignition Proof, C-TICK
}
ATEX II 1/2 D, C-TICK
}
CSA/FM General Purpose, C-TICK
CE, C-TICK
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, C-TICK10)
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, C-TICK
A
B
C
2" NPT [(Taper), ANSI/ASME B1.20.1] ,
sliding sleeve [min. length 500 mm (19.69 inch)]6)
Flanged
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
31
300 ... 500 mm (11.81 ... 19.69 inch)9)
501 ... 750 mm (19.72 ... 29.53 inch)9)
751 ... 1000 mm (29.57 ... 39.37 inch)9)
1001 ... 1250 mm (39.41 ... 49.21 inch)9)
Material process connection/extension
Stainless steel 304 (1.4301)
Stainless steel 316 TI (1.4571)
Process connection
Threaded
7 7 7 7 7 - 77 A 0
} Available ex stock.
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. 2000 mm
(78.74 inch)
Y01
Enhanced sensitivity > 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch)
K05
Enhanced sensitivity < 5 g/l via electronics, increased fork length to 195 mm (7.68 inch), and increased aluminum fork width (available only with
universal voltage, SPDT, CE/FM and CSA General
Purpose approvals)
G01
Signal bulb inserted in M20 cable gland1)
A20
Operating Instructions
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Order No.
7ML1998-5FT62
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
7ML1830-1KL
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1JM
Sliding sleeve, 2" NPT [(Taper),
ANSI/ASME B1.20.1]
7ML1830-1JN
Assembly kit, NAMUR 8/16 mA switch amplifier
A5E03496569
Available ex stock
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection A,
extension length 11, material process connection/extension 1, and approval B
SITRANS LVS200, standard, power supply 7,
process temperature A, process connection B,
extension length 11, material process connection/extension 1, and approval A
1)
5
7ML57317AA11-1BA0
7ML57317AB11-1AA0
Available with approval options C and D only
Siemens FI 01 · 2012
5/109
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVS200, short fork for liquids/solids
interface
Vibrating point level switch for solids or solids
within liquid interface applications, and high load
applications with short insertion requirements
7ML5732-
SITRANS LVS200, short fork for liquids/solids
interface
Vibrating point level switch for solids or solids
within liquid interface applications, and high load
applications with short insertion requirements
7ML5732-
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire2)
5
Process temperature
Without temperature isolator
With temperature isolator
Separated enclosure - cable length 1.5 m (4.92 ft)
[max. temperature process +150 °C (+302 °F)/
max. temperature electronics
+80 °C (+176 °F)]
Separated enclosure - cable length 4.0 m (13.12 ft)
[max. temperature process +150 °C
(+302 °F)/max. temperature electronics
+80 °C (+176 °F)]
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1], sliding sleeve
[min. length 500 mm (19.69 inch)]
2" NPT [(Taper), ANSI/ASME B1.20.1],
sliding sleeve [min. length 500 mm (19.69 inch)]
Flanged
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
7 7 7 77 - 77 A 0
1
2
3
4
5
A
B
C
D
2001 ... 2250 mm (78.78 ... 88.58 inch)4)
2251 ... 2500 mm (88.62 ... 98.43 inch)4)
2501 ... 2750 mm (98.46 ... 108.27 inch)4)
41
42
43
2751 ... 3000 mm (108.31 ... 118.11 inch)4)
3001 ... 3250 mm (118.15 ... 127.95 inch)4)
3251 ... 3500 mm (127.99 ... 137.80 inch)4)
44
45
46
3501 ... 3750 mm (137.83 ... 147.64 inch)4)
3751 ... 4000 mm (147.68 ... 157.48 inch)4)
47
48
1
2
A
B
C
D
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
CE, C-TICK
A
B
C
1)
Available with approval options B, C, D only
Available with approval option D only
Available with material process connection/extension option 1 only
4) Available with material process connection/extension option 2 only
2)
3)
D
Selection and Ordering data
E
F
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
G
H
J
Add order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch)3)
501 ... 750 mm (19.72 ... 29.53 inch)3)
751 ... 1000 mm (29.57 ... 39.37 inch)3)
12
13
14
1001 ... 1250 mm (39.41 ... 49.21 inch)3)
1251 ... 1500 mm (49.25 ... 59.06 inch)3)
1501 ... 1750 mm (59.09 ... 68.90 inch)3)
15
16
17
1751 ... 2000 mm (68.94 ... 78.74 inch)3)
2001 ... 2250 mm (78.78 ... 88.58 inch)3)
2251 ... 2500 mm (88.62 ... 98.43 inch)"3)
18
21
22
2501 ... 2750 mm (98.46 ... 108.27 inch)3)
2751 ... 3000 mm (108.31 ... 118.11 inch)3)
3001 ... 3250 mm (118.15 ... 127.95 inch)3)
23
24
25
3251 ... 3500 mm (127.99 ... 137.80 inch)3)
3501 ... 3750 mm (137.83 ... 147.64 inch)3)
3751 ... 4000 mm (147.68 ... 157.48 inch)3)
26
27
28
Siemens FI 01 · 2012
35
36
37
38
Approvals
11
5/110
1001 ... 1250 mm (39.41 ... 49.21 inch)4)
1251 ... 1500 mm (49.25 ... 59.06 inch)4)
1501 ... 1750 mm (59.09 ... 68.90 inch)4)
1751 ... 2000 mm (68.94 ... 78.74 inch)4)
Material process connection/extension
Stainless steel 304 (1.4301)
Stainless steel 316 TI (1.4571)
Extension length
Stainless steel 304 (1.4301)3)
Standard length, 165 mm (6.50 inch)3)
Stainless Steel 316TI (1.4571)
Standard length, 165 mm (6.50 inch)4)
Add order code Y01 and plain text:
"Insertion length ... mm"
200 ... 500 mm (7.87 ... 19.69 inch) 4)
501 ... 750 mm (19.72 ... 29.53 inch)4)
751 ... 1000 mm (29.57 ... 39.37 inch)4)
7 7 7 77 - 77 A 0
31
32
33
34
Total insertion length: Enter the total insertion length
in plain text description, max. 4000 mm
(157.48 inch)
Y01
Signal bulb inserted in M20 cable gland1)
A20
Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
7ML1998-5FT62
Spare Parts
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
Sliding sleeve, 2" BSP (ISO 228)
7ML1830-1KM
7ML1830-1JM
Sliding sleeve, 2" NPT [(Taper),
ANSI/ASME B1.20.1]
7ML1830-1JN
Assembly kit, NAMUR 8/16 mA switch amplifier
A5E03496569
1)
Available with approval options C and D only
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order No.
Selection and Ordering data
SITRANS LVS200, pipe extension
Vibrating point level switch for high or low levels of
bulk solids
Extended using 1" pipe extension
(customer supplied)
7ML5733-
Further Designs
7 7 7 77 - 77 A 0
Please add "-Z"to Order No. and specify Order
code(s).
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
19 ... 230 V AC/DC without contact, 2-wire loop
powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)3)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire4)
Process temperature
Up to +150 °C (+302 °F)
1
2
3
4
5
6
A
A
B
C
D
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
E
F
G
Application type
Dry bulk solids (125 Hz)
Liquids/solids interface (350 Hz)
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
CE, C-TICK
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, C-TICK5)
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, C-TICK5)
Enhanced sensitivity > 5 g/l via electronics and
increased fork length ... 195 mm (7.68 inch)
K05
Signal bulb inserted in M20 cable gland1)
A20
Operating Instructions
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Order No.
1)
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
Extension length
Customer supplied 1" pipe extension
Length: 300 ... 3800 mm (11.81 ... 149.61 inch)
Y01
Assembly kit, NAMUR 8/16 mA switch amplifier
Flanged
Process connection material
Stainless steel 304 (1.4301)
Stainless steel 316 TI (1.4571)
Total insertion length: Enter the total insertion length
in plain text description, max. 4000 mm
(157.48 inch)
Spare Parts
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)]
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
Order code
7ML1998-5FT62
7ML1830-1KL
7ML1830-1KM
A5E03496569
Available with approval options C and D only
1
2
1
1
2
A
B
C
D
E
F
1)
Available with approval options A to D only
Available with application type 1 only
3)
Available with approval option E and F only
4)
Available with approval option D only
5) Available with power supply option 5 only
2)
Siemens FI 01 · 2012
5/111
5
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
7ML5734-
SITRANS LVS200, cable extended
Vibrating point level switch for high or low level
detection of bulk solids materials
7ML5734-
Power supply
19 ... 230 V AC, 19 ... 55 V DC, one relay output
(SPDT)1)
19 ... 230 V AC, 19 ... 55 V DC, two relay outputs
(DPDT)1)
18 ... 50 V DC PNP1)
19 ... 230 V AC/DC without contact,
2-wire loop powered1)
7 ... 9 V DC (requires NAMUR switch amplifier)
NAMUR IEC 60947-5-6, 2-wire2)3)
8/16 mA or 4 ... 20 mA; 12.5 ... 35 V DC, 2-wire4)
Process temperature
Up to +80 °C (+176 °F)
Process connection
Threaded
R 1½" [(BSPT), EN 10226]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
7 7 7 7 7 - 77 A 0
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
1
2
A
B
C
D
E
CE, C-TICK
CSA/FM IS Class I, II, III Div. 1, Groups A, B, C, D,
E, F, G, FM Class 1, Aex ia IIC, CSA Class 1,
Ex ia IIC, C-TICK6)
ATEX II 1G and 1/2G Eex ia IIC; ATEX II 1D and
1/2D, C-TICK6)
3
4
5
6
F
1)
Available with approval options A to D only
Available with approval options E and F only
Cable length is limited to 10000 mm (393.70 inch)
4)
Available with approval option D only
5) Cable length is limited to 7000 mm (275.59 inch)
6)
Available with power supply option 5 and application type 1 only
2)
A
3)
A
B
Selection and Ordering data
Flanged
5
7 7 7 7 7 - 77 A 0
Order code
Further Designs
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
C
D
Please add "-Z" to Order No. and specify Order
code(s).
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
E
F
G
Total insertion length: Enter the total insertion length
in plain text description, max. 4000 mm
(157.48 inch)
Y01
Enhanced sensitivity > 5 g/l via electronics and
increased fork length to 195 mm (7.68 inch)
K05
Signal bulb inserted in M20 cable gland1)
A20
Operating Instructions
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Order No.
Extension length
700 ... 1000 mm (19.7 ... 39.4 inch) [max. length
20000 mm (787.4 inch), not with Power supply
option 5 (max. 10000 mm, 393.7 inch)]
10
Add order code Y01 and plain text:
"Insertion length ... mm"
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)
3001 ... 4000 mm (118.15 ... 157.48 inch)
11
12
13
4001 ... 5000 mm (157.52 ... 196.85 inch)
5001 ... 6000 mm (196.89 ... 236.22 inch)
6001 ... 7000 mm (236.26 ... 275.59 inch)
14
15
16
Replacement Electronics Module (125 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KL
7001 ... 8000 mm (275.63 ... 314.96 inch)
8001 ... 9000 mm (315 ... 354.33 inch)
9001 ... 10000 mm (354.37 ... 393.70 inch)
17
18
20
Replacement Electronics Module (350 Hz)
[19 ... 230 V AC, 19 ... 55 V DC,
one relay output (SPDT)]
7ML1830-1KM
10001 ... 11000 mm (393.74 ... 433.07 inch)
11001 ... 12000 mm (433.11 ... 472.44 inch)
12001 ... 13000 mm (472.48 ... 511.81 inch)
21
22
23
Assembly kit, NAMUR 8/16 mA switch amplifier
A5E03496569
13001 ... 14000 mm (511.85 ... 551.18 inch)
14001 ... 15000 mm (551.22 ... 590.55 inch)
15001 ... 16000 mm (590.59 ... 629.92 inch)
24
25
26
16001 ... 17000 mm (629.96 ... 669.29 inch)
17001 ... 18000 mm (669.33 ... 708.66 inch)
18001 ... 19000 mm (708.70 ... 748.03 inch)
19001 ... 20000 mm (748.07 ... 787.40 inch)
27
28
30
31
Application type
Dry bulk solids (125 Hz)
Liquid/solids interface (350 Hz)5)
5/112
Siemens FI 01 · 2012
7ML1998-5FT62
Spare Parts
1)
1
2
Available with approval options C and D only
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
View A-A
A
threaded bushing
[max. temp. 80 °C
(176 °F)]
optional sliding
bushing*
thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
60
(2.36)
150
(5.91)
tine orientation
marking
42 (1.67)
165 (6.5): compact solids/ liquids interface model
230 (9.0): compact standard version
300 to 4000
(11.81 to 157): customer-specified rigid extension
42 (1.67)
100 (3.94)
solids/liquids
interface model
tine
tine
170 (6.69):
standard model
100 (3.94)
solids/liquids
interface model
170 (6.69):
standard model
customer supplied
process flange
195 (7.68)
60
(2.36)
700 ... 20 000 (27.56 ... 787)**
120
(4.72)
75
(2.95)
A
155
(6.1)
■ Dimensional drawings
Notes:
* The clamping screws of the sliding bushing must be tightened to 10 Nm.
** Cable version with Liquids/solids interface model option length to 7000 mm (275.59")
Cable version with NAMUR electronics length to 10 000 mm (393.7") tightened to 10 Nm.
See drawing 23650563 for pipe extended version details. (Pipe is customer supplied.)
SITRANS LVS200, dimensions in mm (inch)
Siemens FI 01 · 2012
5/113
5
© Siemens AG 2011
Level Measurement
Point level measurement — Vibrating switches
SITRANS LVS200
■ Schematics
FSH/FSL adjustment
LED
Universal voltage (DPDTrelay)
3-wire PNP
Sensitivity adjustment
(B=factory setting,
A=decreased sensitivity)
B
FSL
Alarm output
relay
1 2
FSH
A
1
3
4
5
7
8
1
9
2
3
load
3 4 5
L N
19 to 230 VAC or
+/- 19 to 55 V DC
PE + Signal output
L N
AC
terminal 1: L, terminal 2: N
19 to 230 VAC, +10 %,
50 to 60 Hz, 18 VA
Protective
earth
terminal
2-wire
PE +
-
DC
terminal 1: +, terminal 2: 18 to 50 V DC, +10 %, 1.5 W
DC
terminal 1: +, terminal 2: 19 to 55 V DC, +10%, 2 W
5
NAMUR IEC 60947-5-6 8/16 mA or 4 to 20 mA
1
PE +
L
2
N
AC
terminal 1: L, terminal 2: N
19 to 230 VAC, +10 %,
50 ... 60 Hz, 1.5 VA
DC
terminal 1: +, terminal 2: 19 to 230 V DC, +10 %, 1 W
SITRANS LVS200 connections
5/114
2
Siemens FI 01 · 2012
1
1
2
2
approx. 7 to 9 V DC,
intrinsically safe
(IEC 60947-5-6)
PE +
L
N
DC
terminal 1: +, terminal 2: 2.5 to 36 V DC, + 0%
PE +
L
N
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Rotating point level switch
Input
Measured variable
High and low, and demand
Output
Output signal
• Alarm output
• Pickup delay
Sensitivity
SITRANS LPS200 is a rotary paddle switch for point level detection in bulk solids.
■ Benefits
•
•
•
•
•
•
•
•
•
Proven paddle switch technology for bulk solids
High integrity mechanical seal
Optional switch selectable power supply
Unique friction clutch mechanism prevents damage from
falling material
Rotatable enclosure for convenient wiring
Optional paddles for use with low density materials
Small paddle makes for simple installation through existing
process connection
High temperature model and optional extension kit available
Optional fail-safe configuration detects loss of rotation
■ Application
The paddle switch technology detects full, empty, or demand
conditions on materials such as grain, feed, cement, plastic
granulate, and wood chips. The paddle switch can handle bulk
densities as low as 15 g/l (2.19 lb/ft3) with the optional rectangular vane or 100 g/l (6.25 lb/ft3) with the standard measuring vane.
A low revolution geared motor with slip clutch drives a rotating
measuring vane which senses the presence of material at the
mounted level of the LPS200. As material comes into contact
with the rotating paddle, rotation stops, which changes the microswitch state. When the paddle is no longer covered by material, rotation resumes and the relay reverts to its normal condition.
The LPS200 has a rugged design for use in harsh conditions in
the solids industry. The sensitivity of the paddle can be adjusted
for varying material properties like buildup on the vane.
The LPS200 comes in a variety of configurations including compact, extended and cable extension. It is equipped with a standard vane which is effective in most applications, but can be
configured with a hinged or rectangular vane for increased sensitivity for light materials.
• Key Applications: bulk solids such as grain, feed, cement,
plastic granulate, wood chips
Microswitch 5 A at 250 V AC,
non inductive
Microswitch SPDT contact 4 A at
30 V DC, non-inductive
Standard (1 rpm model):
approx 1.3 seconds
Optional process applications
(5 rpm model): approx. 0.26 seconds
Adjustable via reset force of
spring or geometry of measuring
vane
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions
• Ambient temperature
• Installation catagory
• Pollution degree
-25 ... +60 °C (-13 ... +140 °F)
III
2
Medium conditions
• Temperature
- Standard
- Optional
• Pressure (vessel)
- Standard
- Optional
• Minimum material density
- Standard measuring vane
- Optional measuring vane
5
Bulk solids
-25 ... +80 °C (-13 ... +176 °F)
-25 ... +600 °C (-13 ... +1112 °F)
Max. 0.5 bar g (7.25 psi g)
Max. 10 bar g (145 psi g)
• Can detect down to 100 g/l
(6.25 lb/ft3)
• Can detect down to15 g/l
(2.19 lb/ft3)
Design
Material
• Enclosure
• Process connection, measuring
shaft and vane
Epoxy coated aluminum
Stainless steel or aluminum
Process connection
Thread NPT, BSP, and flange
options
Degree of protection
IP65/Type 4/NEMA 4
Conduit entry
2 x M20x1.5 or 2 x ½" NPT
Power supply
Jumper selectable
• 115 V AC, ± 15%, 50 ... 60 Hz,
4 VA or 230 V AC, ± 15%, 50 Hz,
6 VA, or 48 V AC, or 24 V AC
• or 24 V DC, ± 15%, 2.5 W
Certificates and approvals
• CSA/FM General Purpose
• CE
• CSA/FM Dust Ignition Proof
• ATEX II 1/2 D
• C-TICK
Siemens FI 01 · 2012
5/115
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LPS200, compact
Rotary paddle switch for level detection in bulk
solids. Compact design for side or top mounted
applications.
7ML5725-
SITRANS LPS200, compact
Rotary paddle switch for level detection in bulk
solids. Compact design for side or top mounted
applications.
7ML5725-
77 7 77 - 777 0
Process temperature
Up to +80 °C (+176 °F)
Up to +150 °C (+302 °F)
Up to +250 °C (+482 °F)
Up to +600 °C (+1112 °F)1)
Up to +80 °C (+176 °F) basic version
aluminum2) 3)
Up to +80 °C (+176 °F) basic version stainless
steel 2) 4)
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
5
Measuring vane
Boot shaped, 35 x 106 mm (1.38 x 4.17 inch)7)
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)7)8)
Boot shaped, 28 x 98 mm (1.10 x 3.86 inch)
1
2
3
77 7 77 - 777 0
}
A
B
C
4
} 5
Rectangular 50 x 150 mm (1.97 x 5.91 inch)9)
Rectangular 50 x 250 mm (1.97 x 9.84 inch)9)
Rectangular 98 x 150 mm (3.86 x 5.91 inch)9)
D
E
F
} 6
Rectangular 98 x 250 mm (3.86 x 9.84 inch)9)
G
}
}
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose , C-TICK
CE, C-TICK
A
B
C
D
E
F
G
H
J
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
}
}
}
}
A
B
C
D
1)
Available with approval option C and D only, up to max. 0.8 bar
2)
Basic version is cost effective and offers fast delivery
3)
Available only with power supply option A and with process connection C,
and approval D, or power supply E with process connection E, and
approval C, and then process pressure 1, process connection material 1,
extension length 2, measuring vane A
K
L
M
4)
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
Available only with power supply option Q, process connection C with
approval B, or process connection E with approval A, and then process
pressure 1, process connection material 2, extension length 2 and measuring vane A
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
N
P
5)
Available with process connections A to F, process pressure option 1,
and process temperature option 1 only
Q
6)
Available with measuring vane options A, C to G, only
7)
Add 16 mm (0.63 inch) to extension length
8)
Available with extension length options 2 to 5 only
9)
Available with process connections G, H, J to M, only
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 5 rev/min.
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
G 1" [(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
}
R
}
}
}
A
B
C
D
E
F
Flanged
DN 32 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
G
H
J
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
K
L
M
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Process connection material
Aluminum5)
Stainless steel 303 (1.4305)
Extension length
100 mm (3.94 inch)6)
150 mm (5.91 inch)
200 mm (7.87 inch)
250 mm (9.84 inch)
300 mm (11.81 inch)
5/116
Siemens FI 01 · 2012
}
}
}
}
1
2
3
1
2
1
2
3
4
5
Available ex stock.
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Heating of enclosure1) 2)
A35
Signal bulb inserted in M20 cable gland1)
A20
SITRANS LPS200 designed for food applications
with shaft seal conforming to FDA standards
K01
Additional Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
Spare Parts
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 210 mm (2.56 x 8.27 inch)
7ML1830-1KJ
Rigid extension kit
(includes spring coupling, rigid tube extension and
required pins)
Extension: 500, 400, 300 mm (19.7, 15.8, 11.8 inch)
7ML5711-0AA
Extension: 1000, 900, 800, 700, 600
(39.4, 35.4, 31.5, 27.6, 23.6 inch)
7ML5711-1AA
Extension: 1500, 1400, 1300, 1200, 1100 mm
(59.1, 55.1, 51.2, 47.2, 43.3 inch)
7ML5711-2AA
5
Available ex stock
SITRANS LPS200, compact for up to
+80 °C (+176 °F), aluminum, with power supply A,
process connection C, process pressure 1,
process connection material 1, extension length 2,
measuring vane A, and approval D
7ML1830-1KG
SITRANS LPS200, compact for up to +80 °C
(+176 °F), aluminum, with power supply E, process
connection E, process pressure 1, process connection material 1, extension length 2,
measuring vane A, and approval C
7ML57255EE11-2AC0
SITRANS LPS200, compact for up to +80 °C
(+176 °F), stainless steel, with power supply Q,
process connection C, process pressure 1, process connection material 2, extension length 2,
measuring vane A, and approval B
7ML57256QC12-2AB0
SITRANS LPS200, compact for up to +80 °C
(+176 °F), stainless steel, with power supply Q,
process connection E, process pressure 1, process
connection material 2, extension length 2, measuring vane A, and approval A
7ML57256QE12-2AA0
1)
2)
Available with approval option D only
Available with power supply options A to H, J to N, P only
Siemens FI 01 · 2012
5/117
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LPS200, shaft protected
Rotary paddle switch for level detection in bulk
solids; ideal for heavy, sticky, or high impact applications.
Designed with added protection tube for enhanced
shaft protection
7ML5726-
SITRANS LPS200, shaft protected
Rotary paddle switch for level detection in bulk
solids; ideal for heavy, sticky, or high impact applications.
Designed with added protection tube for enhanced
shaft protection
7ML5726-
7 7 7 77 - 777 7
Process temperature
Up to +80 °C (+176 °F)
Up to +150 °C (+302 °F)
Up to +250 °C (+482 °F)
Up to +600 °C (+1112 °F)1)
Up to +80 °C (+176 °F) basic version2)
5
Measuring vane
Boot shaped 35 x 106 mm (1.38 x 4.17 inch)6)
Hinged vane 65 x 200 mm (2.56 x 7.87 inch)6)
Rectangular 50 x 150 mm (1.97 x 5.91 inch)7)
1
2
3
4
} 5
A
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
D
E
F
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
G
H
J
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
K
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
N
P
Q
Process connection
Threaded
G 1¼"[(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
}
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
CE, C-TICK
A
B
C
D
Flanged
DN 32 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
E
F
G
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
H
J
K
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
}
Process connection material
Aluminum3) 4)
Stainless steel 303 (1.4305)
}
Extension length
150 mm (5.91 inch)5)
200 mm (7.87 inch)
}
5/118
Siemens FI 01 · 2012
1
2
1
2
3
4
250 mm (9.84 inch)
300 mm (11.81 inch)
Extension material (protection tube)
Aluminum3)
Stainless steel 303 (1.4305)
1
2
3
}
A
B
A
B
D
E
F
G
}
}
1
2
3
4
1)
Available with approval option 3 and 4 only, up to max. 0.8 bar
2)
Available with power supply option Q (process connection B with approval
2 or process connection C with approval 1), process pressure 1, process
connection material 2, extension length 2, protection tube B and measuring vane A only
3)
Available with process connections A to D, and process temperature
option 1 only
4)
Available with process pressure option 1 only
5)
Not available with measuring vane option B
6)
Add 16 mm (0.63 inch) to extension length
7)
Available with process connections E to H, J, K, only
}
R
}
}
}
Rectangular 50 x 250 mm (1.97 x 9.84 inch)7)
Rectangular 98 x 150 mm (3.86 x 5.91 inch)7)
Rectangular 98 x 250 mm (3.86 x 9.84 inch)7)
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 5 rev/min.
7 7 7 77 - 77 7 7
Available ex stock.
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Heating of enclosure1)2)
Signal bulb inserted in M20 cable gland1)
A35
SITRANS LPS200 designed for food applications
with shaft seal conforming to FDA standards
K01
Additional Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
A20
Spare Parts
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 210 mm (2.56 x 8.27 inch)
7ML1830-1KJ
Available ex stock
SITRANS LPS200, extended for up to +80 °C
(+176 °F), power supply Q, process connection B,
process pressure 1, process connection material 2,
extension length 2, extension material B, measuring vane A, and approval 2
7ML57265QB12-2BA2
SITRANS LPS200, extended for up to +80 °C
(+176 °F), power supply Q, process connection C,
process pressure 1, process connection material 2,
extension length 2, extension material B, measuring vane A, and approval 1
7ML57265QC12-2BA1
1)
2)
5
Available with approval option 4 only
Available with power supply options A to H, J to N, P only
Siemens FI 01 · 2012
5/119
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
5
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LPS200, cable extension
Rotary paddle switch for level detection in bulk
solids
Cable extension for increased length in
top-mounted applications
7ML5727-
SITRANS LPS200, cable extension
Rotary paddle switch for level detection in bulk
solids
Cable extension for increased length in
top-mounted applications
7ML5727-
7 7 7 77 - 777 0
Process temperature
Up to +80 °C (+176 °F)
Up to +150 °C (+302 °F)
Up to +250 °C (+482 °F)
1
2
3
Up to +600 °C (+1112 °F)1)
Up to +80 °C (+176 °F) basic version2) 5)
4
5
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
A
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
D
E
F
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
G
H
J
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
N
P
Q
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 5 rev/min.
R
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
A
B
C
D
H
J
K
1
2
3
1
2
0
1
2
3
Cable length 3001 ... 4000 mm
(118.15 ... 157.48 inch)
Cable length 4001 ... 5000 mm
(157.52 ... 196.85 inch)
Cable length 5001 ... 6000 mm
(196.89 ... 236.22 inch)
4
Cable length 6001 ... 7000 mm
(236.26 ... 275.59 inch)
Cable length 7001 ... 10000 mm
(275.63 ... 393.70 inch)
7
5/120
Siemens FI 01 · 2012
A
B
C
D
Available with approval option C and D only, up to max. 0.8 bar
Available only with Power supply Q, (Process connection B with Approvals
B or Process connection C with Approvals A), Process pressure 1, Process
connection material 2, Cable Extension length 0 and Measuring Vane A
3)
Available with process connections A to D, process pressure option 1, and
process temperature option 1 only
4)
Add 16 mm (0.63 inch) to extension length
5) Available with process connections E to H, J, K, only
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
Add order code Y01 and plain text:
"Insertion length ... mm"
500 ... 1000 mm (19.69 ... 39.37 inch)
Cable length 1001 ... 2000 mm
(39.41 ... 78.74 inch)
Cable length 2001 ... 3000 mm
(78.78 ... 118.11 inch)
D
E
F
2)
E
F
G
Cable extension length
Standard cable length, 2000 mm (78.74 inch)
Rectangular 50 x 150 mm (1.97 x 5.91 inch)5)
Rectangular 50 x 250 mm (1.97 x 9.84 inch)5)
Rectangular 98 x 150 mm (3.86 x 5.91 inch)5)
1)
DN 32 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
Process connection material
Aluminum3)
Stainless steel 303 (1.4305)
A
B
C
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
CE, C-TICK
Flanged
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Measuring vane
Boot shaped, 35 x 106 mm (1.38 x 4.17 inch)4)
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)4)
Boot shaped, 28 x 98 mm (1.10 x 3.86 inch)
Approvals
K
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 1 rev/min.
77 7 77 - 777 0
5
6
8
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length:
Enter the total insertion length in plain text description, max. 10000 mm (393.70 inch)
Y01
Reinforced cable (max. 28 kN pulling force)
P01
Heating of enclosure1) 2)
A35
Signal bulb inserted in M20 cable gland1)
A20
Additional Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
Spare Parts
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 210 mm (2.56 x 8.27 inch)
7ML1830-1KJ
Rope extension kit, 2 m (6.56 ft)
7ML1830-1KK
5
Available ex stock
SITRANS LPS200, cable extension for up to +80 °C
(+176 °F), power supply Q, process connection B,
process pressure 1, process connection material 2,
extension length 0, measuring vane A, and approval B
7ML57275QB12-0AB0
SITRANS LPS200, cable extension for up to +80 °C
(+176 °F), power supply Q, process connection C,
process pressure 1, process connection material 2,
extension length 0, measuring vane A, and approval A
7ML57275QC12-0AA0
1)
2)
Available with approval option D only
Available with power supply options A to H, J to N, and P, only
Siemens FI 01 · 2012
5/121
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order No.
Selection and Ordering data
SITRANS LPS200, angled extension
Rotary paddle switch with robust design for level
detection in bulk solids; ideal for heavy or sticky
applications.
Angled extension designed to avoid falling material
and rotate horizontally in side mount applications
7ML5728-
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Process temperature
Up to +80 °C (+176 °F)
Up to +150 °C (+302 °F)
Up to +250 °C (+482 °F)
5
7 7 7 77 - 777 0
1
2
3
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
A
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
D
E
F
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
G
H
J
K
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 1 rev/min.
N
P
Q
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 5 rev/min.
R
Process connection
Flanged
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Process connection material
Stainless steel 303 (1.4305)
Additional Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
A20
Motor gear /PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 210 mm (2.56 x 8.27 inch)
7ML1830-1KJ
2)
A
B
C
1
2
3
1
250 mm (9.84 inch)
300 mm (11.81 inch)
4
5
Measuring vane
Rectangular vane, 50 x 98 mm (1.97 x 3.86 inch)
Rectangular vane, 50 x 150 mm (1.97 x 5.91 inch)
Rectangular vane, 50 x 250 mm (1.97 x 9.84 inch)
A
B
C
Rectangular vane 98 x 150 mm (3.86 x 5.91 inch)
Rectangular vane 98 x 250 mm (3.86 x 9.84 inch)
Hinged vane, 65 x 200 mm (2.56 x 7.87 inch)
D
E
F
Siemens FI 01 · 2012
A35
1)
1
2
3
5/122
Heating of enclosure1) 2)
Signal bulb inserted in M20 cable gland1)
Spare Parts
Extension length
125 mm (4.92 inch)
150 mm (5.91 inch)
200 mm (7.87 inch)
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
CSA/FM General Purpose, C-TICK
CE, C-TICK
Order code
A
B
C
D
Available with approval option D only
Available with power supply options A to H, J to N, P only
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LPS200, rigid extension
Rotary paddle switch for top mount point level
detection in bulk solids
7ML5730-
SITRANS LPS200, rigid extension
Rotary paddle switch for top mount point level
detection in bulk solids
7ML5730-
7 7 7 77 - 777 7
Process temperature
Up to +80 °C (+176 °F)
Up to +150 °C (+302 °F)
1
2
Up to +250 °C (+482 °F)
Up to +600 °C (+1112 °F)1)
3
4
Power supply
230 V AC, 1 rev/min.
230 V AC, 1 rev/min., fail-safe
230 V AC, 5 rev/min.
A
B
C
230 V AC, 5 rev/min., fail-safe
115 V AC, 1 rev/min.
115 V AC, 1 rev/min., fail-safe
D
E
F
115 V AC, 5 rev/min.
115 V AC, 5 rev/min., fail-safe
48 V AC, 1 rev/min.
24 V AC, 1 rev/min.
G
H
J
24 V DC, 1 rev/min.
24 V DC, 1 rev/min., fail-safe
K
L
M
24 V DC, 5 rev/min.
24 V DC, 5 rev/min., fail-safe
N
P
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 1 rev/min.
Switch selectable 230 V AC/115 V AC/24 V DC
multivoltage, 5 rev/min.
Q
Process connection
Threaded
G 1¼" [(BSPP), EN ISO 228-1]
G 1½" [(BSPP), EN ISO 228-1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
Stainless steel 303 (1.4305)
250 ... 500 mm (9.84 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1000 mm (29.57 ... 39.37 inch)
R
S
T
1001 ... 1500 mm (39.41 ... 59.05 inch)
1501 ... 2000 mm (59.09 ... 78.74 inch)
2001 ... 2500 mm (78.78 ... 98.42 inch)
U
V
W
2501 ... 3000 mm (98.46 ... 118.11 inch)
3001 ... 4000 mm (118.14.78 ... 157.48 inch)
X
Y
Measuring vane
Boot shaped, 35 x 106 mm (1.34 x 4.17 inch)8)
Hinged vane, 60 x 200 mm (2.36 x 7.87 inch)
Rectangular 50 x 150 mm (1.97 x 5.91 inch)9)
A
B
C
Rectangular 50 x 250 mm (1.97 x 9.84 inch)9)
Rectangular 98 x 150 mm (3.86 x 5.91 inch)9)
Rectangular 98 x 250 mm (3.86 x 9.84 inch)9)
D
E
F
Approvals
CSA/FM Dust Ignition Proof, C-TICK
ATEX II 1/2 D, C-TICK
1
2
CSA/FM General Purpose, C-TICK
CE, C-TICK
3
4
1)
R
2)
3)
4)
5)
6)
A
B
C
D
77 7 77 - 777 7
7)
8)
9)
Available with approval option 3 and 4 only, up to max. 0.8 bar
Available with process connections A to D only
Available with process pressure option 1 only
Available with extension length options A to Q only
Available with extension length options R to Y only
Available with process connection material option 1 only
Available with process temperature option 1 only
Add 16 mm (0.63 inch) to extension length
Available with process connections E to H, J, K, only
Flanged
DN 32 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 6, EN1092-1 (1.4541/321)
DN 100 PN 16, EN1092-1 (1.4541/321)
E
F
G
2" ASME 150 lbs B16.5 (1.4541/321)
3" ASME 150 lbs B16.5 (1.4541/321)
4" ASME 150 lbs B16.5 (1.4541/321)
H
J
K
Process pressure
Up to 0.5 bar (7.25 psi)
Up to 5 bar (72.5 psi)
Up to 10 bar (145 psi)
Process connection material
Aluminum2) 3) 4)
Stainless steel 303 (1.4305)5)
Extension material (protection tube)
Aluminum2) 4) 6) 7)
Stainless steel 303 (1.4305)5)
1
2
3
1
2
0
1
Extension length
Aluminum
250 ... 500 mm (9.84 ... 19.69 inch)
501 ... 750 mm (19.72 ... 29.53 inch)
751 ... 1000 mm (29.57 ... 39.37 inch)
A
B
C
1001 ... 1250 mm (39.41 ... 42.21 inch)
1251 ... 1500 mm (49.25 ... 59.06 inch)
1501 ... 1750 mm (59.09 ... 68.90 inch)
D
E
F
1751 ... 2000 mm (68.94 ... 78.74 inch)
2001 ... 2250 mm (78.78 ... 88.58 inch)
2251 ... 2500 mm (88.62 ... 98.43 inch)
G
H
J
2501 ... 2750 mm (98.46 ... 108.27 inch)
2751 ... 3000 mm (108.31 ... 118.11 inch)
3001 ... 3250 mm (118.15 ... 127.95 inch)
K
L
M
3251 ... 3500 mm (127.99 ... 137.80 inch)
3501 ... 3750 mm (137.83 ... 147.64 inch)
3751 ... 4000 mm (147.67 ... 157.48 inch)
N
P
Q
Siemens FI 01 · 2012
5/123
5
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
Selection and Ordering data
Order code
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Total insertion length: Enter the total insertion length
in plain text description, max. 4000 mm
(157.48 inch)
Y01
Heating of enclosure1)2)
A35
Signal bulb inserted in M20 cable gland1)
A20
SITRANS LPS200 designed for food applications
with shaft seal conforming to FDA standards3)
K01
Seal at tube end for ingress protection and shaft
stability
5
Max. temperature +80 °C (+176 °F)
P06
Max. temperature +150 °C (+302 °F)
P07
Max. temperature +250 °C (+482 °F)
P08
Max. temperature +600 °C (+1112 °F)
P09
Sliding sleeve (standard, max. pressure 0.8 bar)
P12
Sliding sleeve (pressure tight, for over-pressure
application starting from 1 bar max., dependent on
pressure option ordered)
P13
Additional Operating Instructions
Order No.
Multi-language
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
7ML1998-5FS62
Spare Parts
Motor gear/PLC, multi-voltage
7ML1830-1KG
Replacement vane, boot shape, 35 x 106 mm
(1.38 x 4.17 inch)
7ML1830-1KH
Hinged vane, 65 x 210 mm (2.56 x 8.27 inch)
7ML1830-1KJ
1)
2)
3)
Available with approval option 4 only
Available with power supply options A to H, J to N, P, only
Available when ordered with ingress protection seal P06 to P09 only
5/124
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
■ Dimensional drawings
Standard model: compact version
High temperature model: compact version
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
Ambient temperature
-25 ... +60 °C
(-13 ... +140 °F)
60 (2.36)
75 (2.95)
120 (4.72)
9.84
300
11.81
1)
L
Optional
process
flange
Zone
20
Shaft protected
option
1)
Process temperature 2)
-25 ... +220 °C
(-13 ... +428 °F)
Angle option
L
1)
125 ... 300
(4.92 ... 8.46)
Measuring vane
Rope
fixing
Measuring vanes
35 (1.38)
106
(4.17)
Rectangular
Hinged
Fold
together
to lead
into
mounting
hole
50 (1.97)
50 (1.97)
A
min. 37
(1.46)
Rectangular vane options
A
B
65
(2.56)
Standard
210 (8.27)
Vane
B
98 (3.86)
150 (5.90)
50 1.97)
250 (9.84)
98 (3.86)
150 (5.90)
98 (3.86)
250 (9.84)
1. For 35 x 106 mm boot shaped and 65 x 210 mm hinged
measuring vanes, add 16 mm to extension length.
2. For use with all approval options except CSA class II. See
manual for more details.
Notes
For heavy material, only top mounting of paddle switch is
recommended.
Compact LPS200 is recommended for side mounting on bins
for low or intermediate material levels.
5
Rope option
2000 (78.74) standard;
Can be shortened by the customer;
total length available 10000 (393.7)
Zone
20
Thread length
BSP: 20.5 (0.81)
NPT: 24 (0.94)
7.87
250
L
Zone
21
Process temperature
-25 ... +80 °C
(-13 ... +176 °F)
3.94
5.91
150
200
Zone
21
123
(4.84)
Ambient temperature
-25 ... +60 °C
(-13 ... +140 °F)
L= Length
100
340 (13.4)
60 (2.36)
Conduit connection
M20 or ½" NPT
Completely covered
with material
Covered up to 10 cm (3.93")
with material
Spring adjustment
Spring adjustment
light
boot shaped
35 x 106 mm
boot shaped
28 x 98 mm
rectangular
50 x 98 mm
rectangular
50 x 150 mm
rectangular
50 x 250 mm
rectangular
98 x 150 mm
rectangular
98 x 250 mm
hinged
65 x 210 mm
hinged
60 x 200 mm
200 g/l
(12.5 lb/ft³)
300 g/l
(18.7 lb/ft³)
300 g/l
(18.7 lb/ft³)
80 g/l
(5.0 lb/ft³)
30 g/l
(1.9 lb/ft³)
30 g/l
(1.9 lb/ft³)
20 g/l
(1.2 lb/ft³)
70 g/l
(4.4 lb/ft³)
70 g/l
(4.4 lb/ft³)
central
(factory setting)
300 g/l
(18.7 lb/ft³)
500 g/l
(31.2 lb/ft³)
500 g/l
(31.2 lb/ft³)
120 g/l
(7.5 lb/ft³)
50 g/l
(3.1 lb/ft³)
50 g/l
(3.1 lb/ft³)
30 g/l
(1.9 lb/ft³)
100 g/l
(6.2 lb/ft³)
100 g/l
(6.2 lb/ft³)
light
100 g/l
(6.2 lb/ft³)
150 g/l
(9.4 lb/ft³)
150 g/l
(9.4 lb/ft³)
40 g/l
(2.5 lb/ft³)
15 g/l
(0.9 lb/ft³)
15 g/l
(0.9 lb/ft³)
15 g/l
(0.9 lb/ft³)
35 g/l
(2.2 lb/ft³)
35 g/l
(2.2 lb/ft³)
central
(factory setting)
150 g/l
(9.4 lb/ft³)
150 g/l
(9.4 lb/ft³)
250 g/l
(15.6 lb/ft³)
60 g/l
(3.7 lb/ft³)
25 g/l
(1.6 lb/ft³)
25 g/l
(1.6 lb/ft³)
15 g/l
(0.9 lb/ft³)
50 g/l
(3.1 lb/ft³)
50 g/l
(3.1 lb/ft³)
SITRANS LPS200, dimensions in mm (inch)
Siemens FI 01 · 2012
5/125
© Siemens AG 2011
Level Measurement
Point level measurement — Rotating paddle switches
SITRANS LPS200
■ Schematics
Switch Selectable Connection
AC or DC version, SPDT relay, fail-safe
M
Switching and timing behaviour:
If the vane is not covered, the rotating vane
shaft will send pulses at 20 second intervals.
In case of fault, the pulses are missed. After
30 seconds, the alarm relay will open.
8
7
6
5
1
Alarm output
relay
L N
115 V AC 50 to 60 Hz
230 V AC 50 Hz
or ±24 V DC
Voltage Selector
24 V
115 V
5
230 V
SITRANS LPS200 connections
5/126
Siemens FI 01 · 2012
7
6
5
1
2
L
N PE
24 V or 48 V or 115 V or 230 V AC,
50/60 Hz, 5 VA
+
- PE
24 V DC, 2.5 W
All voltages ±15%
2
Alarm
output
Signal
output
OR
© Siemens AG 2011
Level Measurement
Point level measurement — Tilt switch
Tilt Switch Probe
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Tilting of encapsulated mercury
switch
Typical application
• High or low level alarm on bulk
solids
• High or low level alarm for
liquids (when used with float
option)
Features
Number of points
Single point destination
Output
• 2 A at 24 V DC
Transducers
Tilt angle sensitive mercury
contacts
Characteristics
Probe (Tilt Switch)
• Resolution: nominal 17° from
vertical
Design
The Milltronics Tilt Switch probe is an electro-mechanical tilt
switch for point level detection, plugged chute detection, and
feed loss detection on conveyor belts.
■ Benefits
•
•
•
•
High or low alarm
Easy installation and operation
Low cost
Customized options
Housing
• Schedule 80 stainless steel pipe
with ½" NPT mounting for extensions
Material type
• Stainless steel:
- low temperature:
-40 ... +90 °C (-40 ... +194 °F)
- high temperature:
-40 ... +150 °C (-40 ... +302 °F)
Weight
• 2 kg (4.4 lb)
Approvals
CE, C-TICK
Options
Extensions: stainless steel wear,
cross paddle, flat paddle, or float
■ Application
Tilt switches provide point level detection. They offer a costeffective solution for point level detection, plug chute detection,
belt tracking, and feed loss detection on conveyor belts. They
also provide simple high and low alarms for both dry bulk solids
and liquids.
The Tilt switch consists of a rugged, stainless steel encapsulated probe. The probe is suspended vertically over a bin or belt,
and the potted switch inside the probe provides a signal when
material tilts it through an angle of more than 17° in any direction.
Additional assembly options are available including replaceable
wear extensions (for coarse and abrasive materials), flat or cross
paddles (for medium bulk density materials), and
floats (for liquids or light density bulk materials). The probes are
also available for high or low temperature applications.
• Key Applications: point level detection, belt mis-alignment,
conveyor feed starvation detection
Siemens FI 01 · 2012
5/127
5
© Siemens AG 2011
Level Measurement
Point level measurement — Tilt switch
Tilt switch probe
Order No.
C) 7MH7143Tilt Switch Probe
Offers a cost-effective solution for point level detec- 7 7 7 7 0
tion, plug chute detection, belt tracking and feed
loss detection on conveyor belts.
Temperature Rating
Low temperature with 6 m (20 ft.) of cable
High temperature with 1.5 m (5 ft.) of cable
Probe Extension
None
Wear extension, stainless steel
Cross paddle extension, stainless steel
Flat paddle extension, stainless steel
Float, stainless steel
■ Selection and Ordering data
1/2" NPT
(internal thread)
for connection
to conduit
A
A
B
1
3
5
7
8
1/2" NPT
(internal
thread)
for connection
to optional
extensions
Material
304 stainless steel (1.4301)
Cable
• Low temperature 6 m (20 ft):
Type SJO 18-2
• High temperature 1.5 m (5 ft):
shielded PTFE
Order No.
Optional extensions (material: 304 stainless steel)
Further Designs
Please add "-Z" to Order No. and specify Order
code(s).
Wear
Instruction manual
C) 7ML1998-1FL01
TSP Probe, English
Note: The instruction manual should be ordered as
a separate item on the order.
Flat paddle
1/2"
effective
thread
100 (4)
150 (6)
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and instruction manuals.
1/2" NPT for
connection to probe
Spare parts
Float, stainless steel
C) 7MH7723-1DH
Wear extension, stainless steel
C) 7MH7723-1DJ
Cross paddle, stainless steel
C) 7MH7723-1DK
Flat paddle, stainless steel
C) 7MH7723-1DL
10 0
(4)
)
25 (1
C) Subject to export regulations AL:N, ECCN: EAR99.
Float
Cross paddle
1/2" NPT for
connection to probe
130
(5.1
)
100 (4)
150 (6)
145 (5.7) approx.
Ø114 (4.5)
5
Cable
3
150 (6)
overall
Sensor Construction
Stainless steel
Tilt Switch Probe
245 (10)
Model
Standard, CE approved
■ Dimensional drawings
180 (7)
■ Selection and Ordering data
(5
130
Tilt switch, dimensions in mm (inch)
5/128
Siemens FI 01 · 2012
.1)
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Ultrasonic
■ Overview
■ Mode of operation
Introduction
Common Terms
Ultrasonic measurement is based on the speed of sound. Sound
can be used as a measurement tool because there is a measurable time lapse between sound generation and the "hearing" of
the sound. This time lapse is then converted into usable information. Ultrasonic sensing equipment generates a sound above
20000 Hz and then interprets the time lapse of the returned
echo. The transducer creates the sound and senses the echo
and then a transceiver interprets the sound and converts it into
information.
Attenuation
Siemens ultrasonic units include Sonic Intelligence, a patented
signal processing technology. Using unique algorithms, Sonic
Intelligence differentiates between true echoes from the material
and false echoes from obstructions or electrical noise, providing
intelligent processing of echo profiles.
Typical System
Ultrasonic level measurement requires two components: one to
generate the sound and catch the echo (transducer) and one to
interpret the data and derive a measurement (transceiver). Even
though some ultrasonic instruments combine the components in
one unit, the individual functionality remains distinct. The measurement output is communicated to the unit, PLCs or PCs for
process control.
Principle of Operation
A piezoelectric crystal inside the transducer converts an electrical signal into sound energy, firing a burst into the air which travels to the target and then is reflected back to the transducer. The
transducer then acts as a receiving device and converts the
sonic energy back into an electrical signal contained in the
transceiver. An electronic signal processor analyzes the return
echo and calculates the distance between the transducer and
the target. The time lapse between firing the sound burst and
receiving the return echo is directly proportional to the distance
between the transducer and the material in the vessel. This basic principle lies at the heart of the ultrasonic measurement technology and is illustrated in the equation:
Distance = (Velocity of Sound x Time)/2.
Denotes a decrease in signal magnitude in transmission from
one point to another. Attenuation may be expressed as a scalar
ratio of the input magnitude to the output magnitude or in decibels.
Beam angle
The diameter of a conical boundary centered around the axis of
transmission when the power (radiating perpendicular to the
transducer face on the axis of transmission) is reduced by half
(-3 dB).
Blanking distance
Specified zone extending downward from the transducer face in
which received echoes are ignored by the transceiver. Blanking
distance ignores echoes from ringing.
Echo confidence
The recognition of the validity of the echo as material level.
A measure of echo reliability.
Ringing
The inherent nature of the transducer to continue vibrating after
the transmit pulse has ceased; the decay of the transmit pulse.
Transducer/Transceiver
A transducer provides the initial ultrasonic pulse and receives its
echo. An ultrasonic transducer amplifies the sound wave created by the piezoelectric crystal and transmits that sound wave
to the face of the transducer while at the same time dampening
the sound wave from the other sides of the crystal.
Transceivers analyze the echo from the transducer to determine
the required measurement.
Siemens FI 01 · 2012
5/129
5
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Ultrasonic
■ Technical specifications
Ultrasonics Transmitter/Controller Selection Guide
5
Criteria
SITRANS
Probe LU
HydroRanger
200
Range
6 m (20 ft) or
12 m (40 ft)
15 m (50 ft) trans15 m (50 ft) trans15 m (50 ft) trans60 m (200 ft) trans- 3 m (10 ft)
ducer and applica- ducer and applica- ducer and applica- ducer and application dependent
tion dependent
tion dependent
tion dependent
Typical applications
Chemical storage
vessels, filter
beds, liquid
storage vessels
Wet wells,
flumes/weirs, bar
screen control
Wet wells,
flumes/weirs, bar
screen control,
hoppers, chemical storage, liquid
storage, crusher
bins, dry solids
storage
Wet well/lift station
control,
weirs/flumes,
open channels
Chemical storage,
liquid storage, bulk
solids storage
(sugar, flour bins,
grains, cereals),
plastic pellets
Output
HART model:
4 to 20 mA/HART
PROFIBUS PA
model: PROFIBUS
6 relays standard,
two 4 to 20 mA
outputs (isolated)
1 relay (option on
MultiRanger 100)
3 relays standard
6 relays (option)
Two 4 to 20 mA
outputs (isolated)
5 relays, 4 to
20 mA (option)
4 relays (LU01,
3 relays,
LU02)
4 to 20 mA
Up to 40 relays
(LU10)
4 to 20 mA isolated
Communications
HART or
PROFIBUS PA
Options:
• SIMATIC PDM for
remote configuration and
diagnostics
Built-in Modbus
RTU/ASCII via
RS-485
Options:
• SIMATIC PDM
• SmartLinx
(PROFIBUS DP,
Allen-Bradley
Remote I/O,
DeviceNet)
Built-in Modbus
RTU or ASCII via
RS-485
Options:
• SIMATIC PDM
• Smartlinx
(PROFIBUS DP,
Allen-Bradley
Remote I/O,
DeviceNet)
Telemetry capability with Modbus
RTU/ASCII via
RS-232/RS-485
Options:
• SIMATIC PDM
• SmartLinx (PROFIBUS DP, AllenBradley Remote
I/O, DeviceNet)
• ECT EnviroRanger Tool software
Dolphin,
RS-232/RS-485
(LU01, LU02))
Dolphin via
infrared (LU10)
Options:
• SmartLinx
(PROFIBUS DP,
Allen-Bradley
Remote I/O,
DeviceNet)
Via RS-232
Options:
• Flow Reporter
software
Power specifications
HART: 4 to 20 mA,
24 V DC nominal,
max. 550 W,
30 V DC max.
PROFIBUS PA: 12,
13, 15, or 20 mA,
dependent on
programming
AC version: 100 to
230 V AC ±15 %,
50/60 Hz,
36 VA/17 W
DC version:
12 to 30 V DC,
20 W
AC version:
100 ... 230 V AC
±15 %, 50/60 Hz,
36 VA/17 W
DC version:
12 to 30 V DC,
20 W
AC version:
100... 230 V AC
±15 %, 50/60 Hz,
30 VA/17 W
DC version:
12 to 30 V DC,
20 W
LU01, LU02:
AC version:
100/115/200/
230 V AC
DC version:
18 to 30 V DC,
25 W
LU10:
100/115/200/
230 V AC
100/115/200/230 V
AC, ±15 %,
50/60 Hz, 15 VA
and/or
9 to 30 V DC, 8 W
Approvals
CE, CSAUS/C, FM,
C-TICK, ATEX,
ANZEx, IECEx
CE, CSAUS/C,
UL Listed, FM,
C-TICK
CE, CSAUS/C,
UL Listed, FM,
C-TICK
CE, CSAUS/C,
UL Listed
CE, CSAUS/C, FM,
Lloyd’s Register
CE, CSAUS/C, FM
5/130
Siemens FI 01 · 2012
MultiRanger
100/200
SITRANS LUC500
SITRANS LU
OCM III
Open channel
measurement
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Ultrasonic
7ML1830-2AN
7ML5830-2AJ
7ML1830-2AA
7ML1830-2AK
SITRANS Probe LU HART*
SITRANS LU
SITRANS Probe LU PROFIBUS
OCM III
MultiRanger 100/200
HydroRanger 200
HydroRanger Plus
SITRANS LUC500
* Note: To order the IS version of this hand programmer, order 7ML5830-2AH.
Handheld programmer selection guide
5
Siemens FI 01 · 2012
5/131
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Ultrasonic
Ultrasonic Level Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Address:
Notes on the Application:
City:
Country:
Zip/Postal Code:
Phone: (
E-mail:
Fax: (
Tanks/Vessel information
5
Type:
)
)
(Supply sketch where possible)
Sketch attached
Storage
Dimensions:
Process
Height:
m/ft
Nozzle Length:
cm/in
Pump station
Width/Diameter:
m/ft
Nozzle Diameter:
cm/in
Critical Information
Open channel
Open
Tank top:
Sloped
Internal equipment
and/or obstructions:
Flat
Flat
(E.g. Agitator, Heating coils,
Supports, Other)
Conical
Conical
Parabolic
Parabolic
Tank bottom:
Continuous Level
Point Level
Measurement type:
Volume
No
Yes
Please list
Flow
Area safety classification: (specify code required)
Material
Slurry
Material being measured:
°C/°F Max:
Material temperature: Norm:
Atmosphere:
Air
Other
Dust:
None
Light
Installation
Liquid
Solid
°C/°F
Homogenous:
Yes
No
Heavy
(indicate all that apply)
Power available:
Communications:
Inputs required:
Outputs required:
4 to 20 mA
Pump Interlocks (#):
HART ® /4 to 20 mA
AB Remote I/O
4 to 20 mA
PROFIBUS DP
AB DeviceNet
Relays (#):
PROFIBUS PA
None
Modbus RTU/ASCII
Products recommended:
© Siemens Milltronics Process Instruments Inc.
5/132
Siemens FI 01 · 2012
www.siemens.com/processautomation
Form# 2-769R3
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Pointek ULS200
■ Overview
■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting devices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water, and wastewater industries. A
sanitary version of the ULS200, with an industry standard flange
option, is easy to remove from the application for cleaning. It
thus satisfies the prerequisites for use in the food, beverage, and
pharmaceutical industries. The Pointek ULS200 delivers superior performance while reducing maintenance, downtime, and
equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
The Pointek ULS200 is an ultrasonic non-contacting switch with
two switch points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for sticky materials.
■ Benefits
• 2 switch outputs for high-high, high, low, and low-low level
alarms or pump up/pump down control
• Integral temperature compensation
• AC or DC power supply
• Electronics provided with fail-safe function
• Threaded and sanitary fitting clamp process connections
• Polycarbonate or aluminum enclosures, Type 6/NEMA 6/IP67
• Easy, two-button programming
■ Design
Installation
The Pointek ULS200 should be mounted in an area that is within
the temperature range specified and that is suitable to the enclosure rating and materials of construction. The cover should be
accessible to allow programming, wiring and display viewing.
It is advisable to keep the Pointek ULS200 away from high voltage or current runs, contactors and SCR control drives.
Locate the Pointek ULS200 so that it has a clear sound path
perpendicular to the material surface. The sound path should
not intersect the fill path, rough walls, seams, rungs etc.
Mounting and Interconnection
The Pointek ULS200 is available in three thread types: 2" NPT,
R 2" (BSPT), EN 10226 or PF2 and can be fitted with the optional
75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65,
PN 10, and JIS 10K 3B sized flanges.
Separate cables and conduit may be required to conform to
standard instrumentation wiring or electrical codes.
Siemens FI 01 · 2012
5/133
5
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Pointek ULS200
■ Configuration
Parabolic mounting
5
Flat mounting and Beam angle
Fill
Pipe
Rungs
Seams
12°
Beam angle
Pointek ULS200 Mounting
5/134
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Pointek ULS200
■ Technical specifications
Mode of operation
Measuring principle
Electronics/enclosure
Connection: terminal block,
max. 2.5 mm2 (14 AWG) solid/
1.5 mm2 (16 AWG) stranded
Ultrasonic level switch
Measuring range
Degree of protection
IP67/Type 6/NEMA 6
Measuring range in liquids
0.25... 5 m (0.8 ... 16.4 ft)
Cable inlet
2 x ½" NPT or 2 x PG 13.5
Measuring range in bulk solids
0.25 ... 3 m (0.8 ... 9.8 ft)
Certificates and approvals
• CE (EMC certificate available on
request), CSA US/C, FM
• CSA/FM Class I, II, III, Div. 1, Gr A, B,
C, D, E, F, G T4
• ATEX II 2G Ex d mb IIC T5 Gb
• C-TICK, ANZEx Ex ds IIC T5,
DIP A21 T5, IP65/IP67
• INMETRO Br-Ex d mb IIC T5
Output
AC Version (relay)
2 SPDT Form C contacts rated 5 A at
250 V AC, resistive load
DC Version (relay)
2 SPDT Form C contacts rated 5 A at
48 V DC
DC Version (transistor)
2 switches, rated max. 100 mA,
48 V DC
Accuracy
AC/DC version
• Resolution
• Repeatibility
3 mm (0.1 inch)
0.25% of measuring range
■ Options
Flange adapter for mating 2" NPT or 2" BSP process connections
to 3" ASME, DN 65 PN10 and JIS 10K 3B flanges
148,8 (5.86)
Bolt hole circle
diameter
Rated operation conditions
Installation conditions
• Location
• Beam angle
Indoors/outdoors
12°
Ambient conditions
• Ambient temperature
• If mounted in metal threads
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-5 t ... +140 °F)
Medium conditions
• Process pressure
0.5 bar (7.25 psi) max.
5
190,2 (7.49)
Diameter
Pointek ULS200 Optional Flange Adapter, dimensions in mm (inch)
Design
Material
Polycarbonate or epoxy-coated
aluminum with gasket
Weight
Approx. 1.5 kg (3.3 lb)
Transducer material
PVDF or ETFE copolymer
Threaded mounting
2" NPT
[(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
For 3" ASME, DN 65, PN 10 and
JIS 10 K3B
• Optional flange adapter
Sanitary mounting
4" sanitary fitting clamp
Power supply
AC version
100 ... 230 V AC, ± 15%, 50/60 Hz,
max. 12 VA, 5 W
DC version
18 ... 30 V DC, 3 W
Displays and controls
Display
LCD, three digits, 9 mm (0.35 inch)
high, for display of distance between
sensor face and material, multisegment graphic for operating state
Memory
EEPROM, non-volatile
Programming
2 keys
Siemens FI 01 · 2012
5/135
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Pointek ULS200
Selection and Ordering data
Order No.
C) 7ML1510Pointek ULS200
Ultrasonic non-contacting switch with two switch
777 0 7
points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for sticky materials
Power supply
24 V DC, relay output
24 V DC, transistor output
100 ... 230 V AC, relay output
5
1
2
3
Selection and Ordering data
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
Quick Start manual, multi-language
Approvals
CE, C-TICK, CSA Class I, II, III, Div. 11)
CE, C-TICK, FM Class I, II, III, Div. 11)
F
G
CE, C-TICK, CSA Class I, II, Div. 22)
CE, C-TICK, CSA us/c, FM
CE, C-TICK, ATEX II 2G Ex d mb IIC T5 Gb3)
J
K
L
INMETRO Br-Ex d mb IIC T53)
C-TICK, ANZEx Ex ds IIC T5, DIP A21 T5,
IP65/IP673)
M
N
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s)
Y15
Order No.
C) 7ML1998-1XB83
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
Universal Box Bracket Mounting Kit
7ML1930-1AC
7ML1830-1BK
3" ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
3" ASME, DN 65, PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
2" BSPT Locknut, plastic
7ML1830-1BT
2" NPT Locknut
7ML1830-1DT
4" sanitary mounting clamp
7ML1830-1BR
7ML1830-1BU
Transducer/Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
EFTE, R 2" [(BSPT), EN 10226]
EFTE, G 2" [(BSPP), EN ISO 228-1]
A
B
C
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G [(BSPP), EN ISO 228-1]
E
F
G
Spare Parts
Polycarbonate Lid
7ML1830-1LG
PVDF copolymer, 4" sanitary mounting4)
J
Aluminum Lid
7ML1830-1LH
C) Subject to export regulations AL: N, ECCN: EAR99.
Enclosure/cable inlet
Polycarbonate
• Cable inlet PG 13.5
• Cable inlet ½" NPT
1
2
Aluminum
• Cable inlet PG 13.5
• Cable inlet ½" NPT
3
4
1)
Available with Enclosure/cable inlet option 4 only and process connection
options A and E only
2)
Available with Enclosure/cable inlet options 2 and 4 only
3)
Available with Enclosure/cable inlet option 4 only
4) Available with Approvals option K only
C) Subject to export regulations AL: N, ECCN: EAR99.
5/136
Siemens FI 01 · 2012
7ML1830-1DQ
© Siemens AG 2011
Level Measurement
Point level measurement — Ultrasonic switch
Pointek ULS200
■ Dimensional drawings
■ Schematics
Relay Output
Threaded
1
60
(2.35)
lid clip
#8-32x3/8”
machine screw
2
100 ... 230 V AC
50/60 Hz
74 (2.9)
57
(2.25)
L
N
1
2
+
-
3
4
5
6
7
8
9
Two Form ‘C’(SPDT) relays can switch
external devices such as alarms, relays,
contractors, PLCs, DCSs, etc.
or
18 ... 30 V DC
lid
Transistor Output: DC version only
conduit
connection
½” NPT or
PG 13.5
1
2
180 (7.1)
18 ... 30 V DC
+
2” NPT
R 2” BSPT
or PF2
22 (0.87)
74 (2.9)
transducer
Sanitary
1
2
3
4
5
6
7
8
5
9
Two non-polarized transistor outputs are
suitable for connection to PLCs, DCSs,
or customer supplied relays.
Pointek ULS200 connections
180 (7.1)
74 (2.9)
Pointek ULS200, dimensions in mm (inch)
Siemens FI 01 · 2012
5/137
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
The Probe
■ Overview
■ Configuration
Parabolic Mounting
The Probe is a short-range integrated ultrasonic level transmitter,
ideal for liquids and slurries in open or closed vessels.
5
■ Benefits
•
•
•
•
•
Easy to install, program and maintain
Accurate and reliable
Sanitary models available
Patented Sonic Intelligence echo processing
Integral temperature compensation
Flat Mounting and Beam Angle
Fill
■ Application
The transducer is available in PVDF copolymer, making the
device suitable for use in a wide variety of applications.
The Probe is easy to install and maintain, and can be quickly
removed for cleaning as required by the food, beverage and
pharmaceutical industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between the
true echo and false echoes from acoustic or electrical noises
and agitator blades in motion. The ultrasonic pulse propagation
time to the material and back is temperature-compensated
and converted into distance for display, analog output and relay
actuation.
• Key Applications: chemical storage vessels, filter beds,
mud pits, liquid storage vessels, food applications
5/138
Siemens FI 01 · 2012
Pipe
Rungs
Seams
12°
Beam angle
The Probe mounting
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
The Probe
■ Technical specifications
Three-wire version
Two-wire version
(standard)
Order No.
C) 7ML1201The Probe
Short-range integrated ultrasonic level transmitter,
777 0 0
ideal for liquids and slurries in open or closed vessels
Ultrasonic
level measurement
Ultrasonic
level measurement
Measuring range
5 m (16.40 ft)
Selection and Ordering data
Mode of operation
Measuring principle
Measuring range
0.25 ... 5 m
(0.8 ... 16.4 ft)
0.25 ... 5 m
(0.8 ... 16.4 ft)
Output
mA
4 ... 20 mA
4 ... 20 mA
• Span
Proportional/
inversely proportional
Proportional/
inversely proportional
• Max. load
750 Ω at 24 V DC
600 Ω in the loop at
24 V DC
Relay
For level alarm or fault No
Power supply
Supply voltage
18 ... 30 V DC,
max. 0.2 A
12 ... 28 V DC,
0.1 A surge
Max. power
consumption
5W
(200 mA at 24 V DC)
0.75 W
(25 mA at 24 V DC)
Certificates and
approvals
CE, C-TICK, CSAUS/C, CE, C-TICK, CSAUS/C
FM
Accuracy
Error in measurement
Resolution
Temperature compensation
Echo processing
E
PVDF copolymer, 2" NPT [(Taper),
ANSI/ASME B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1]
PVDF copolymer, 4" Sanitary mounting
F
G
J
Model/Approval
3 Wire, 24 V DC, CE, C-TICK, CSA, FM
2 Wire, 24 V DC, CE, C-TICK, CSA
E
F
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75")]: Measuring-point number/identification (max. 20 characters) specify in plain text
Y17
Additional Operating Instructions
Order No.
3 Wire, 24 V model, Multi-language manual
C) 7ML1998-5GD62
2 Wire model, Multi-language manual
C) 7ML1998-5GC63
0.25 % of measuring range (in air)
3 mm (0.125")
Built in
Accessories
Universal Box Bracket Mounting kit
7ML1830-1BK
Sanitary 4" mounting clamp
Sonic Intelligence
Rated operation
conditions
Beam angle
1
Transducer/Process connection
Input
12°
Ambient temperature
7ML1830-1BR
Power Supply, 24 V DC, 200 mA for 2 probes
(105 ... 125 V AC input)
C) 7ML1930-1AA
Power Supply, 24 V DC, 100 mA for 1 probe
(105 ... 125 V AC input)
C) 7ML1930-1AB
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
• Standard
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
• Metallic mounting
Max. static operating
pressure
Normal atmospheric pressure
2" NPT locknut, plastic
7ML1830-1DT
2" BSPT locknut, plastic
7ML1830-1DQ
Degree of protection
IP65
Plastic M20 cable gland with metal locknut
7ML1930-1DB
Design
SITRANS RD100 Remote display - see Chapter 8
Weight
SITRANS RD200 Remote display - see Chapter 8
• Without flange a
dapter
1.5 kg (3.3 lbs)
• With flange adapter
1.7 kg (3.7 lbs)
Material
• Electronics enclosure
• Transducer
C) Subject to export regulations AL: N, ECCN: EAR99.
PVC
K) Subject to export regulations AL: N, ECCN: 5A991X.
PVDF copolymer
Degree of protection
IP65
Process connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
Cable inlet
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
2 inlets for PG 13.5 or ½" NPT cable glands
Siemens FI 01 · 2012
5/139
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
The Probe
■ Options
■ Dimensional drawings
Standard Model
hinged lid
7 (0.3)
Flange adapter for mating 2" NPT or 2" BSP process connections
to 3" ANSI, DN 65 PN10, and JIS 10K 3B flanges
148,8 (5.86)
bolt hole circle
diameter
84 (3.3) max.
190,2 (7.49)
diameter
cable entry
‘knock out’
The Probe Optional Flange Adapter, dimensions in mm (inch)
279 (11)
117 (4.6)
electronics
87
(3.4) Ø
The Probe with FMS 200 Mounting Bracket
5
74
(2.9)
mounting
thread
mounting
thread
transducer
53 (2.1) max.
61 (2.4)
hinged lid
The Probe with Optional Mounting Bracket
■ Schematics
7 (0.3)
Sanitary Model
84 (3.3) max.
3 Wire Model
(Standard and Sanitary Models)
cable entry
‘knock out’
mA Output: 4-20 mA, nonisolated, 750 ohms max.
87
(3.4) Ø
279 (11)
117 (4.6)
electronics
process
connection
74
(2.9)
Power supply
Connect to protective earth
Relays: dry contact, closed
unpowered or alarm state
61 (2.4)
2 Wire Model
(Standard and Sanitary Models)
Probe
+
–
Loop
instrumentation
R max
+ –
1 2
R max =
V supply
V supply – 12 V
+
20 mA
12 to 28 V DC –
Display
program
mode
segment
display
'20' key
units
'4' key
operation
status
The Probe connections
5/140
Siemens FI 01 · 2012
LOE/fault
The Probe, dimensions in mm (inch)
transducer
53 (2.1) max.
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
SITRANS Probe LU
■ Overview
■ Configuration
Parabolic mounting
SITRANS Probe LU is a 2-wire loop powered ultrasonic
transmitter for level, volume and flow monitoring of liquids in
open channels, storage vessels, and simple process vessels.
■ Benefits
• Continuous level measurement up to 12 m (40 ft) range
• Easy installation and simple start-up
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART Communicator
• Communication using HART or PROFIBUS PA
• ETFE or PVDF transducers for chemical compatibility
• Patented Sonic Intelligence signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression for fixed obstruction avoidance
• Level to volume or level to flow conversion
■ Application
Fill
Pipe
Rungs
Seams
10°
The SITRANS Probe LU is ideal for level monitoring in the water
and wastewater industry and chemical storage vessels.
The range of SITRANS Probe LU is 6 or 12 m (20 or 40 ft).
Using Auto False-Echo Suppression for fixed obstruction
avoidance, as well as an improved signal-to-noise ratio and
improved accuracy of 0.15% of range or 6 mm (0.25"),
the Probe LU provides unmatched reliability.
5
Flat mounting and beam angle
Beam angle
SITRANS Probe LU mounting
SITRANS Probe LU includes Sonic Intelligence signal processing from the field-proven Probe and incorporates new
echo processing features and the latest micro-processor
and communications technology. The Probe LU offers two
communications options: HART or PROFIBUS PA
(Profile version 3.0, Class B).
The transducer on the Probe LU is available as ETFE or PVDF
to suit the chemical conditions of your application. As well,
for applications with varying material and process temperatures,
the Probe LU incorporates an internal temperature sensor to
compensate for temperature changes.
• Key Applications: chemical storage vessels, filter beds,
liquid storage vessels
Siemens FI 01 · 2012
5/141
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
SITRANS Probe LU
■ Technical specifications
Mode of operation
Process connection
Measuring principle
Ultrasonic level measurement
Typical application
Level measurement in storage
vessels and simple process
vessels
• Threaded connection
2" NPT [(Taper),
ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
Inputs
• Flange connection
3" (80 mm) universal flange
Measuring range
• Other connection
FMS 200 mounting bracket (see
page 5/198) or customer supplied
mount
• 6 m (20 ft) model
0.25 ... 6 m (10" ... 20 ft)
• 12 m (40 ft) model
0.25 ... 12 m (10" ... 40 ft)
Frequency
54 kHz
Display and Controls
Interface
Local: LCD display with bar graph
Remote: Available via HART or
PROFIBUS PA
Configuration
Using Siemens SIMATIC PDM
(PC) or HART handheld communicator or Siemens infrared handheld programmer
Performance
Memory
Non-volatile EEPROM
Resolution
≤ 3 mm (0.12")
Power supply
Accuracy
± the greater of 0.15 % of range
or 6 mm (0.24")
4 ... 20 mA/HART
Repeatability
≤ 3 mm (0.12")
Nominal 24 V DC with
550 Ω maximum;
maximum 30 V DC 4 ... 20 mA
PROFIBUS PA
Blanking distance
0.25 m (10")
Update time
≤5s
• 4/20 mA/HART version
≤ 5 s at 4 mA
12, 13, 15, or 20 mA
depending on programming
(General Purpose or Intrinsically
Safe version)
• PROFIBUS version
≤ 4 s at 15 mA current loop
Temperature compensation
Built-in to compensate over
temperature range
General
10°
Marine (only applies to HART
communication option)
Outputs
mA/HART
5
• Range
4 ... 20 mA
• Accuracy
± 0.02 mA
PROFIBUS PA
Profile 3, Class B
Beam angle
Rated operating conditions
per IEC 61158-2
Certificates and Approvals
CSAUS/C, FM, CE, C-TICK
• Lloyd’s Register of Shipping
• ABS Type Approval
Hazardous
Ambient conditions
• Intrinsically Safe (Europe)
ATEX II 1G EEx ia IIC T4
• Intrinsically Safe (USA/Canada)
CSA/FM (barrier required) T4,
Class I, Div. 1, Groups A, B, C, D;
Class II, Div. 1, Groups E, F, G;
Class III
• Intrinsically Safe
(Australia/New Zealand)
ANZEx Ex ia IIC T4,
Tamb = -40 ... +80 °C
(-40 ... +176 °F) IP67, IP68
Medium conditions
• Intrinsically Safe (International)
IECEx TSA 04.0020X Ex ia IIC T4
• Temperature at flange or threads
-40 ... +85 °C (-40 ... +185 °F)
• Intrinsically Safe (Brazil)
INMETRO Br-Ex ia IIC T4
0.5 bar g (7.25 psi g)
• Non-incendive (USA)
FM (no barrier required) T5:
Class I, Div. 2, Groups A,B,C, D
• Location
Indoor/outdoor
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Relative
humidity/ingress protection
Suitable for outdoor
• Installation category
I
• Pollution degree
4
• Pressure (vessel)
Design
Material (enclosure)
PBT (Polybutylene Terephthalate)
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6/IP67/IP68 enclosure
Weight
2.1 kg (4.6 lbs)
Cable inlet
2 x M20x1.5 cable gland or
2 x ½" NPT thread or
1 x M20 x 1.5 and 1 x ½" NPT
Material (transducer)
5/142
Siemens FI 01 · 2012
ETFE
(Ethylene Tetrafluoroethylene) or
PVDF (Polyvinylidene Fluoride)
Handheld Programmer
Intrinsically Safe Siemens handheld
programmer
Infrared receiver
• Approvals for handheld
programmer
IS model with ATEX EEx ia IIC T4
CSA/FM Class I, Div. 1, Groups A,
B, C, D
Ambient temperature
-20 ... +40 °C (-5 ... +104 °F)
Interface
Proprietary infrared pulse signal
Power
3 V lithium battery
(non-replaceable)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
SITRANS Probe LU
Order No.
C) 7ML5221SITRANS Probe LU
2-wire, loop powered ultrasonic transmitter for
7 7 7 77
level, volume and flow monitoring of liquids in
open channels, storage vessels, and simple
process vessels.
Selection and Ordering data
Enclosure/Cable Inlet
Plastic (PBT), 1 x M20x1.5 and 1 x ½” NPT
(no cable glands supplied)
Plastic (PBT), 2 x M20x1.5 (includes 1 general
purpose cable gland: 7ML1930-1AM)
Plastic (PBT), 2 x ½" NPT (no cable glands supplied)
0
C) 7ML1998-5HT02
2
French
C) 7ML1998-5HT12
C
D
21)
C) 7ML1998-5HT32
German
Note: The Operating Instructions should be ordered
as a separate item on the order.
C) 7ML1998-5QR81
Additional Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
A
B
C
Operating Instructions for PROFIBUS PA device
English
1
2
1
4
5
Intrinsically safe, ATEX II 1 G EEx ia IIC T4, ANZEx,
IECEx, INMETRO, CE, C-TICK 3)
Intrinsically safe, CSA/FM Class I, Div. 1, Groups A,
B, C, D; Class II, Div. 1 Group E, F, G; Class III T43)
7
Available with Enclosure/Cable Inlet option 2 only.
2)
Available with communication option 2 only.
3)
Available with communication option 1 only.
C) Subject to export regulations AL: N, ECCN: EAR99.
C) 7ML1998-5JB02
C) 7ML1998-5JB32
German
Note: The Operating Instructions should be ordered
as a separate item on the order.
FM, Class l, Div.
Intrinsically Safe, CSA/FM Class I, Div. 1, Groups A,
B, C, D (barrier required); Class II, Div. 1, Groups E,
F, G; Class III2)
Intrinsically Safe, ATEX II 1G EEx ia IIC T42)
1)
Order No.
English
12 meter (40 ft), ETFE
12 meter (40 ft), PVDF Copolymer
Approvals
General Purpose, FM, CSA, CE, C-TICK
Y15
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions for HART/mA device
A
B
Communication/Output
4 ... 20 mA, HART
PROFIBUS PA
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
1
Range/Transducer material
6 meter (20 ft), ETFE
6 meter (20 ft), PVDF Copolymer
Process connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
G 2" [(BSPP), EN ISO 228-1]
Order code
Selection and Ordering data
6
8
C) 7ML1998-5QV81
Additional Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
Optional equipment
Handheld programmer, Intrinsically Safe, EEx ia
7ML5830-2AH
Handheld programmer, General Purpose approvals
7ML1830-2AN
Handheld programmer, Infrared, Intrinsically Safe,
PROFIBUS PA
7ML5830-2AJ
HART modem/RS-232
(for use with PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
2" NPT locknut, plastic
7ML1830-1DT
2" BSPT locknut, plastic
7ML1830-1DQ
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
One General Purpose polymeric cable gland
M20x1.5, rated for -20 ... +80 °C (-4 ... +176 °F)
7ML1930-1AM
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F) for General Purpose
or ATEX EEx e installations (available for HART only)
7ML1930-1AP
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F) with integrated shield
connection (available for PROFIBUS PA)
7ML1930-1AQ
Probe LU, rock guard/sunshield kit, 304 SS
C) 7ML1930-1GH
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Spare Parts
7ML1830-1KB
Plastic lid
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/143
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
SITRANS Probe LU
■ Options
Flange adapter for mating 2" NPT or 2" BSP process connections to
3" ASME, DN 65 PN 10 and JIS 10K 3B flanges
SITRANS Probe LU with FMS 200 Mounting Bracket
148.8 (5.86)
Bolt hole circle
diameter
190.2 (7.49)
Diameter
SITRANS Probe LU optional flange adapter, dimensions in mm (inch)
SITRANS Probe LU with optional mounting bracket
139.7 (5.50)
■ Dimensional drawings
5
Hinged lid
21
(0.83)
198.9 (7.83)
130.1 (5.12)
51.1
(2.01)
54 (2.13)
Note: Above model is shown without M20 cable glands or 1/2" NPT conduit connectors.
SITRANS Probe LU, dimensions in mm (inch)
5/144
Siemens FI 01 · 2012
Electronics
Mounting thread
Transducer
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transmitters
SITRANS Probe LU
■ Schematics
Connect the wires to the
terminals as shown:
the polarity is identified
on the terminal block.
Lid screws
Terminals for loop current
or PROFIBUS PA cable
Cable
Watertight
gland
5
Note:
-
HART model above is shown with M20 cable glands. 1/2" NPT threaded connection is also available.
DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS Probe LU connections
Siemens FI 01 · 2012
5/145
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger 200
■ Overview
■ Application
For water authorities, municipal water, and wastewater plants,
HydroRanger 200 is an economical, low-maintenance solution
delivering control efficiency and productivity needed to meet today’s exacting standards. It offers single point monitoring with all
models, and optional dual-point monitoring with 6 relay model.
As well, it has digital communications with built-in Modbus RTU
via RS-485.
The standard 6 relay HydroRanger 200 will monitor open channel flow and features more advanced relay alarming and pump
control functions as well as volume conversion. It is compatible
with SIMATIC PDM, allowing for PC configuration and setup.
Sonic Intelligence advanced echo-processing software provides increased reading reliability. The optional 1 or 3 relay models provide accurate level measurement functions only; these
two models do not provide open channel flow, differential level
measurement or volume conversion functions.
5
HydroRanger 200 is an ultrasonic level controller for up to six
pumps and provides control, differential control, and open
channel flow monitoring.
■ Benefits
• Monitors wet wells, weirs and flumes
• Digital communications with built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM
configuration software
• Single or dual point level monitoring
• 6 relay (standard), 1 or 3 relay (optional)
• Auto False-Echo Suppression for fixed obstruction avoidance
• Anti-grease ring/tide mark buildup
• Differential amplifier transceiver for common mode noise
rejection and improved signal-to-noise ratio
• Wall and panel mounting options
5/146
Siemens FI 01 · 2012
HydroRanger 200 uses proven continuous ultrasonic echo ranging technology to monitor water and wastewater of any consistency up to 15 m (50 ft) in depth. Achievable resolution is 0.1%
with accuracy to 0.25% of range. Unlike contacting devices,
HydroRanger 200 is immune to problems caused by suspended
solids, harsh corrosives, grease or silt in the effluent, reducing
downtime.
• Key Applications: wet wells, flumes/weirs, bar screen control
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger 200
■ Technical specifications
Mode of Operation
Design
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft),
transducer dependent
Measuring points
1 or 2
Input
Analog
Discrete
0 ... 20 mA or 4 ... 20 mA,
from alternate device, scaleable
(6 relay model)
10 ... 50 V DC switching level
Logical 0 = < 0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Weight
• Wall mount
1.37 kg (3.02 lbs)
• Panel mount
1.50 kg (3.31 lbs)
Material (enclosure)
Polycarbonate
Degree of protection (enclosure)
• Wall mount
IP65/Type 4X/NEMA 4X
• Panel mount
IP54/Type 3/NEMA 3
Cable
• Transducer and mA output signal
2-core copper conductor, twisted,
shielded, 300 Vrms, 0.82 mm²
(18 AWG), Belden 8760 or
equivalent is acceptable
• Max. separation between
transducer and transceiver
365 m (1200 ft)
Displays and controls
100 x 40 mm (4 x 1.5") multi-block
LCD with backlighting
Programming
Programming using handheld
programmer or via PC with
SIMATIC PDM software
Output
Echomax transducer
44 kHz
Ultrasonic transducer
Compatible transducers: ST-H
and Echomax series XPS-10/10F,
XPS 15/15F, XCT-8, XCT-12 and
XRS-5
Relays1)
Rating 5 A at 250 V AC,
non-inductive
• Model with 1 relay2)
1 SPST Form A
Power supply4)
• Model with 3 relays2)
2 SPST Form A/1 SPDT Form C
AC version
• Model with 6 relays
4 SPST Form A/2 SPDT Form C
100 ... 230 V AC ± 15%, 50/60 Hz,
36 VA (17 W)
mA output
• Max. load
0 ... 20 mA or 4 ... 20 mA
DC version
12 ... 30 V DC (20 W)
750 Ω, isolated
Certificates and approvals
• Resolution
0.1 % of range
• CE, C-TICK5)
• Lloyd's Register of Shipping
• ABS Type Approval
• FM, CSAUS/C, UL listed
• CSAUS/C Class I, Div. 2, Groups
A, B, C and D, Class II, Div. 2,
Groups F and G, Class III
(wall mount only)
• MCERTS Class 1 approved for
Open Channel Flow
Communication
• RS-232 with Modbus RTU or
ASCII via RJ-11 connector
• RS-485 with Modbus RTU or
ASCII via terminal blocks
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
- Allen-Bradley Remote I/O
Accuracy
Error in measurement
0.25% of range or 6 mm (0.24"),
whichever is greater
Resolution
0.1% of measuring range or 2 mm
(0.08"), whichever is greater3)
Temperature compensation
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor in
transducer
• External TS-3 temperature
sensor (optional)
• Programmable fixed
temperature values
Rated operating conditions
1)
Installation conditions
• Location
indoor / outdoor
• Installation category
II
• Pollution degree
4
Ambient conditions
Ambient temperature (enclosure)
All relays certified for use with equipment that fails in a state at or under the
rated maximums of the relays
This model is level control only; no open channel flow, differential level or
volume conversion functions
3) Program range is defined as the empty distance to the face of the transducer plus any range extension
4)
Maximum power consumption is listed
5)
EMC performance available upon request
2)
-20 ... +50 °C (-4 ... +122 °F)
Siemens FI 01 · 2012
5/147
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger 200
Order No.
L) 7ML5034Siemens HydroRanger 200
Ultrasonic level controller for up to six pumps that
77 7 77
provides control, differential control and open
channel flow monitoring. The HydroRanger 200 is
also available as a level measurement controller
only. Select option from number of measurement
points options below.
Selection and Ordering data
Mounting
Wall mount, standard enclosure
Wall mount, 4 entries, 4 M20 cable glands included
Panel mount1)
Power supply
100 ... 230 V AC
12 ... 30 V DC
Number of measurement points
Single point model, 6 relays
Dual point model, 6 relays
Single point model, level only, 1 relay2)
Single point model, level only, 3 relays2)
5
Communication (SmartLinx)
Without module
SmartLinx Allen-Bradley Remote I/O module
SmartLinx PROFIBUS DP module
SmartLinx DeviceNet module
See SmartLinx product page 5/120 for more information.
Approvals
General Purpose CE, FM, CSAUS/C, UL listed, C-TICK
CSA Class I, Div. 2, Groups A, B, C and D; Class II,
Div 2, Groups F and G; Class III (for wall mount
applications only)
1)
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Order No.
Operating Instructions
1
2
3
English
C) 7ML1998-5FC03
French
C) 7ML1998-5FC11
C) 7ML1998-5FC33
German
Note: The Operating Instructions should be ordered as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
A
B
A
B
C
D
Other Operating Instructions
0
1
2
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
C) 7ML1998-1BH02
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the
order.
3
Accessories
1
2
Available with approval option 1 only
This model is level control only; no open channel flow, differential level,
or volume conversion functions
L) Subject to export regulations AL: N, ECCN: 3A991X.
2)
Order code
Selection and Ordering data
Handheld programmer
7ML1830-2AK
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosure
7ML1930-1AC
Sunshield kit, 304 SS
7ML1930-1GA
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Spare parts
Power Supply Board (100 ... 230 V AC)
C) 7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
C) 7ML1830-1ME
Display Board
C) 7ML1830-1MF
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/148
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger 200
■ Dimensional drawings
■ Schematics
Wall mount version
14.9
160.3 (6.325)
(0.58)
15.2
130 (5.125)
(0.6)
Mounting
holes
Ø 4.3
(0.17) (x4)
TB1
See note 1
91
(3.58)
6.6
(0.26)
TB1
TB2
+
240 (9.45)
227 (8.93)
Cover
screws
(x6)
L2/N L1
-
- +
2
TB3
12-30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
Suitable location for
conduit entrances
Siemens Milltronics
recommends using a hole
punch for drilling the holes.
2
+
+
Relay 3
TS-3
-
Panel mount version
SHIELD
1
Relay 4
198 (7.80)
36
(1.40)
+
-
4 - 20 mA
OUTPUTS
Relay 2
Housing
Mounting screw
(provided by customer)
Mounting holes
(accessed under lid)
Ø 4.3 (0.17) (x4)
97
(3.82)
Relay 5
DISCRETE
INPUTS
5
2
COM
278 (10.94)
Relay 6
RS485
Relays shown in released
state
A
B
Notes
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1200 ft.). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
HydroRanger 200, dimensions in mm (inch)
3. Connect all cable shields to the HydroRanger 200 Shield
Connections. Avoid differential ground potentials by not connecting
cable shields to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
HydroRanger 200 connections
Siemens FI 01 · 2012
5/149
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
MultiRanger 100/200
■ Overview
■ Application
MultiRanger can be used on different materials, including fuel
oil, municipal waste, acids, woodchips, or on materials with high
angles of repose. MultiRanger offers true dual point monitoring,
digital communications with built-in Modbus RTU via RS-485, as
well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence
advanced echo-processing software for increased reading
reliability.
MultiRanger 100 offers cost-effective level alarming, as well as
on/off and alternating pump control. MultiRanger 200 will monitor
open channel flow and features more advanced relay alarming
and pump control functions as well as volume conversion.
It is compatible with chemical-resistant Echomax transducers
that can be used in hostile environments at temperatures as high
as +145 °C (+293 °F).
• Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins, dry
solids storage
MultiRanger is a versatile short to medium-range ultrasonic
single and multi-vessel level monitor/controller for virtually any
application in a wide range of industries.
5
The MultiRanger is available in wall or panel mounting options.
■ Benefits
• Digital input for back-up level overide from point level device
• Communication using built-in Modbus RTU via RS-485
• Compatible with SmartLinx system and SIMATIC PDM
configuration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise
reduction and improved signal-to-noise ratio
• MultiRanger 100: level measurements, simple pump control,
and level alarm functions
• MultiRanger 200: level, volume and flow measurements in
open channels, differential control, extended pump control,
and alarm functions
• Wall and panel mounting options
5/150
■ Design
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
MultiRanger 100/200
■ Technical specifications
Mode of Operation
Design
Measuring principle
Ultrasonic level measurement
Weight
Measuring range
0.3 ... 15 m (1 ... 50 ft)
• Wall mount
1.37 kg (3.02 lbs)
Measuring points
1 or 2
• Panel mount
1.50 kg (3.31 lbs)
Material (enclosure)
Polycarbonate
Input
• Analog (MultiRanger 200 only)
0 ... 20 mA or 4 ... 20 mA, from
alternate device, scaleable
• Discrete
10 ... 50 V DC switching level
Logical 0 =< 0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Degree of protection (enclosure)
• Wall mount
IP65/Type 4X/NEMA 4X
• Panel mount
IP54/Type 3/NEMA 3
Electrical connection
• Transducer and mA output signal
Output
Echomax transducer
44 kHz
Ultrasonic transducer
Compatible transducers: ST-H
and Echomax series XPS-10/10F,
XPS 15/15F, XCT-8, XCT-12, and
XRS-5
Relays
Rating 5 A at 250 V AC,
non-inductive
• Version with 1 relay
(MultiRanger 100 only)
1 SPST Form A
• Version with 3 relays
2 SPST Form A/1 SPDT Form C
• Version with 6 relays
4 SPST Form A/2 SPDT Form C
mA output
• Max. load
• Resolution
0.1% of range
• Max. separation between
transducer and transceiver
365 m (1200 ft)
Displays and controls
100 x 40 mm (4 x 1.5") multi-block
LCD with backlighting
• Programming
Programming using hand-held
programmer, SIMATIC PDM or via
PC with Dolphin Plus software
Power supply
• AC version
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA (17 W)
0 ... 20 mA or 4 ... 20 mA
• DC version
12 ... 30 V DC (20 W)
750 Ω, isolated
Certificates and approvals
• CE, C-TICK 2)
• Lloyd’s Register of Shipping
• ABS Type Approval
• FM, CSAUS/C, UL listed
• CSA Class I, Div. 2, Groups A, B,
C and D, Class II, Div.2, Groups
F and G, Class III (wall mount
only), ATEX II 3D
Communication
• RS-232 with Modbus RTU or
ASCII via RJ-11 connector
• RS-485 with Modbus RTU or
ASCII via terminal strips
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
- Allen-Bradley Remote I/O
Accuracy
• Error in measurement
00.25% of range or 6 mm (0.24"),
whichever is greater
• Resolution
0.1 % of measuring range1)
or 2 mm (0.08"), whichever is
greater
• Temperature compensation
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature sensor (optional)
• Programmable fixed temperature values
Rated operating conditions
Installation conditions
• Location
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
1)
Indoor/outdoor
• Installation category
II
• Pollution degree
4
2)
Program range is defined as the empty distance to the face of the
transducer plus any range extension
EMC performance available on request
Ambient conditions
• Ambient temperature (housing)
-20 ... +50 °C (-4 ... +122 °F)
Siemens FI 01 · 2012
5/151
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
MultiRanger 100/200
Selection and Ordering data
Order No.
Versions
MultiRanger 100, level measurement only
MultiRanger 200, level, volume, flow and differential
measurements
Mounting, enclosure design
Wall mount, standard enclosure
Wall mount, 4 entries, 4 M20 cable glands included
Panel mount (CE, CSAUS/C, FM, UL)
Power supply
100 ... 230 V AC
12 ... 30 V DC
Number of measurement points
Single point version
Dual point version
5
Communication (SmartLinx)
Without module
SmartLinx Allen-Bradley Remote I/O module
SmartLinx PROFIBUS DP module
SmartLinx DeviceNet module
See SmartLinx product page 5/120 for more information.
Output relays
3 relays (2 Form A, 1 Form C), 250 V AC
6 relays (4 Form A, 2 Form C), 250 V AC
1 relay (1 Form A), 250 V AC (available on
MultiRanger 100 model only)
Approvals
General Purpose CE, FM, CSAUS/C,
UL listed, C-TICK
CSA Class I, Div. 2, Groups A, B, C and D; Class II,
Div 2, Groups F and G; Class III1)
ATEX II 3D2)
1)
2)
Order code
Selection and Ordering data
L) 7ML5033MultiRanger 100/200
Versatile short to medium-range ultrasonic single
77 7 77 - 77
and multi-vessel level monitor/controller for virtually
any application in a wide range of industries
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
1
2
Y15
Order No.
Operating Instructions
A
B
C
A
B
English
C) 7ML1998-5FB06
French
C) 7ML1998-5FB13
Spanish
C) 7ML1998-5FB23
German
C) 7ML1998-5FB36
C) 7ML1998-5QD83
Quick Start guide, multi-language
Note: The Operating Instructions should be ordered
as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
0
1
Other Operating Instructions
0
1
2
3
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
C) 7ML1998-1BH02
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the
order.
1
2
3
Accessories
Handheld programmer
7ML1830-2AK
7ML1930-1AC
A
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosure
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
B
Sunshield kit, 304 SS
7ML1930-1GA
C
SITRANS RD100 Remote display - see Chapter 8
For wall mount applications only
For standard enclosure wall mount, option A only
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Spare parts
Power Supply Board (100 ... 230 V AC)
C) 7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
C) 7ML1830-1ME
Display Board
C) 7ML1830-1MF
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/152
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
MultiRanger 100/200
■ Dimensional drawings
■ Schematics
Wall mount version
14.9
160.3 (6.325)
(0.58)
15.2
130 (5.125)
(0.6)
Mounting
holes
Ø 4.3
(0.17) (x4)
91
(3.58)
6.6
(0.26)
TB1
L2/N L1
+
240 (9.45)
227 (8.93)
Cover
screws
(x6)
TB1
See note 1
TB2
- +
2
TB3
12-30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
Suitable location for
conduit entrances
Siemens Milltronics
recommends using a hole
punch for drilling the holes.
2
36
(1.40)
+
+
Relay 3
TS-3
-
Panel mount version
198 (7.80)
+
-
4 - 20 mA
OUTPUTS
Relay 2
Housing
Mounting screw
(provided by customer)
Mounting holes
(accessed under lid)
Ø 4.3 (0.17) (x4)
SHIELD
1
Relay 4
97
(3.82)
Relay 5
DISCRETE
INPUTS
5
2
COM
278 (10.94)
Relay 6
RS485
Relays shown in released
state
A
B
Note:
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1200 ft.). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
MultiRanger, dimensions in mm (inch)
3. Connect all cable shields to the MultiRanger Shield Connections.
Avoid differential ground potentials by not connecting cable shields
to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
MultiRanger connections
Siemens FI 01 · 2012
5/153
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger Plus
■ Overview
■ Benefits
• Outputs for alarms, chart recorders, controllers and integration of existing systems
• Monitors wet wells, weirs and flumes
• Energy-saving function with built-in real-time clock
• Special control mode to reduce grease rings and other
deposits
• Integral temperature compensation
• Pump performance monitoring
• System monitoring and network analysis
■ Application
The system is effective in wet wells, weirs, and flumes where
foam and turbulence are typical operating conditions. It can be
customized to meet your specific application needs – from measuring flow rate in a narrow flume to volume in a ferric chloride
storage bank.
The system consists of the electronics housed in a wall-mounted
enclosure and a hermetically sealed, corrosion-resistant Echomax transducer. These components can be separated by up to
365 m (1200 ft).
5
HydroRanger Plus is an ultrasonic level controller for control of
wet wells and reservoir pump operations, differential control, and
open channel flow monitoring, using energy-saving algorithms.
5/154
Siemens FI 01 · 2012
Optional submergence shields ensure consistent operation in
wet wells where the transducer may be submerged during flooding from rainfall or a power outage. Siemens patented detection
software can differentiate between a submerged condition and
a high level.
• Key Applications: wet wells, weirs, flumes
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger Plus
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft)
Measuring points
1 or 2
Power supply
100/115/200/230 V AC, ±15%,
50/60 Hz, 15 VA and/or
9 ... 30 V DC, 8 W
Ultrasonic transducer
Compatible transducers: ST-H
and Echomax series XPS-10/10F,
XPS 15/15F, XCT-8, XCT-12 and
XRS-5
Output
Ultrasonic transducer
44 kHz
Displays and controls
Relays
5 alarm/control relays, 1 SPDT
Form C per relay, rated 5 A at
250 V AC, resistive load
Rack and panel mount
75 x 20 mm (3 x 0.8") LCD
(selectable backlighting)
mA output
0/4 ... 20 mA, optically isolated
Wall mount
100 x 40 mm (4 x 1.5") multifield
LCD, backlit
• Max. load
1 kΩ
Programming
• Resolution
0.1 % of 20 mA
Removable programmer or
optional Dolphin Plus
Memory
EEPROM (non-volatile), no
backup battery required
Certificates and approvals
CE2), FM, CSAUS/C, C-TICK
Accuracy
Error in measurement
0.25% of range or 6 mm (0.24"),
whichever is greater
Resolution
0.1% of measuring range or
2 mm (0.08"), whichever is
greater1)
Temperature compensation
-50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature
sensor (optional)
• Programmable fixed temperature
1)
The measuring range corresponds to the distance from the zero point to the
sensor face, plus any range extension.
2) EMC certificate available on request
5
Rated operating conditions
Ambient conditions
• Ambient temperature for enclosure
-20 ... +50 °C (-4 ... +122 °F)
Design
Rack mount
DIN 3 HU/14 pitch, 4 rail plug-in
unit suitable for standard
84 pitch (19") rack
Panel mount
Suitable for standard panel
cutout DIN 43700, 72 x 144 mm,
100 mm center height
Degree of protection (wall mount)
IP65/NEMA 4X/Type 4X
Weight (rack and panel mount)
0.87 kg (1.9 lbs)
Weight (wall mount)
1.5 kg (3.3 lbs)
Material (enclosure)
Polyester/polycarbonate alloy
Electrical connection
Commercially available copper
conductor according to local
requirements, rated 250 V/5 A
Ultrasonic transducer cable
extension
RG 62-A/U coaxial cable with
low capacitance
mA output signal
2-core copper conductor,
twisted, shielded,
0.5 ... 0.75 mm² (22 ... 18 AWG),
Belden 8760 or equivalent is
acceptable
Siemens FI 01 · 2012
5/155
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger Plus
Selection and Ordering data
Order No.
L) 7ML1028HydroRanger Plus, wall mount
Non-contacting ultrasonic echo ranging technology
7A7 7 0
monitor that comes standard with a backlit display
Measuring range: 0.3 m to 15 m (1 ... 50 ft)
Mounting/device version
Version for 19" rack
(requires terminal block; see accessories)
Version for panel
Input voltage
100 V AC, 9 ... 30 V DC
115 V AC, 9 ... 30 V DC
1
2
200 V AC, 9 ... 30 V DC
230 V AC, 9 ... 30 V DC
3
4
Approvals
CE (EN 61326), CSAUS/C, FM, C-TICK
1
2
C
Input voltage
100 V AC, 9 ... 30 V DC
115 V AC, 9 ... 30 V DC
A
B
200 V AC, 9 ... 30 V DC
230 V AC, 9 ... 30 V DC
C
D
Selection and Ordering data
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
Approvals
CE; FM General Purpose; CSA Class I, Div. 2,
C-TICK
C
Mounting/enclosure version
Standard enclosure (NEMA 4X)
Standard enclosure prepared for five M20 cable
glands
1
3
C) Subject to export regulations AL: N, ECCN: EAR99.
L) Subject to export regulations AL: N, ECCN: 3A991X.
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
5
Order No.
Selection and Ordering data
L) 7ML1025HydroRanger Plus, rack and panel mount
Non-contacting ultrasonic echo ranging technology
777 0 1
monitor that comes standard with a backlit display
Measuring range: 0.3 m to 15 m (1 ... 50 ft)
K) Subject to export regulations AL: N, ECCN: 5A991X.
Order code
Selection and Ordering data
Y15
Order No.
English
C) 7ML1998-1AC02
French
C) 7ML1998-1AC12
C) 7ML1998-1AC32
German
Note: The Operating Instructions should be ordered
as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Order No.
Operating Instructions
English
C) 7ML1998-1AC02
French
C) 7ML1998-1AC12
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
C) 7ML1998-1AC32
German
Note: The Operating Instructions should be ordered
as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
Accessories
Other Operating Instructions
C) 7ML1998-1BH02
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the
order.
Accessories
Handheld programmer
7ML1830-2AC
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosure
7ML1930-1AC
Terminal block for rack mount
7ML1830-1JL
Handheld programmer
7ML1830-2AC
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one
text line, suitable for enclosure
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
Sunshield kit, 304 SS
7ML1930-1GA
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Spare parts
Spare parts
Card, mother main
C) 7ML1830-1LV
Card, Analog HydroRanger Plus Rack/Panel
C) 7ML1830-1LR
Card, daughter
C) 7ML1830-1LW
Card, daughter
C) 7ML1830-1LS
Card, display
C) 7ML1830-1LU
Card, display, backlit
C) 7ML1830-1LX
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/156
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger Plus
■ Dimensional drawings
■ Schematics
Rack Mount
DIN 3U/14HP, 4 rail plug-in unit suitable for standard 84 HP (19")
subrack. (Terminal is customer supplied or available as optional
accessory.)
mA In
mA In
+ C2
A2
–
black C4
A4
+
white C6
A6
–
shield C8
A8
sync
black C10
A10 +
9 - 30
white/shield C12
See Note 2
com C14
A12 –
V
TS-3
mA Out
See
Note 1
Sensor
n.o. C18
A18 n.c.
white/shield C20
A20 n.o.
com C22
A22 com
n.c. C24
A24 n.c.
n.o. C26
A26 n.o.
com C28
A28
n.c. C30
A30 L2 / N
n.o. C32
A32 L1
Panel Mount
201 (7.9)
16 (0.6)
144 (5.7)
150 (5.9)
Relay 4
Relay 3
Slip on mounting bracket top and
bottom screws to be tightened to no
more than 5.9 Nm (1 inch/lb) torque.
See
Note 4
2. Use RG-62 A/U coaxial (or equivalent) for extensions up to
365 m (1200 ft). Run in grounded metal conduit, separate from
other wiring.
77
(3.0)
102 (4.0)
180 (7.1)
20 (0.8)
5
Relay 1
1. Required only if mounted adjacent to other Siemens Milltronics
equipment. Interconnect all ‘SYNC’ terminals with a single
18 AWG (0.5 mm 2) wire.
195 (7.7)
168 (6.6)
See
Relay 2 Note 3
Notes
Wall Mount
13 (0.5)
Shield
A16 com
Relay 5
72 (2.9)
A14
n.c. C16
3. Each relay has 1 set of Form ‘C’ (SPDT) contacts relay rated at
5 A 250 V AC, non-inductive, when equal or lower rated limiting
fuses are installed. Relay de-energized when in alarm conditions
and energized for pump control.
4. Before applying AC power (mains), ensure the correct voltage is
selected. Never operate the HydroRanger Plus with the ground
(earth) wire disconnected.
Voltage Selection
Suitable location for conduit
entrances. Use watertight
conduit hubs to maintain
enclosure rating.
HydroRanger Plus, dimensions in mm (inch)
mounting holes,
Ø4.5 mm (0.18"),
4 places
Voltage Selection
Switches
HydroRanger Plus connections, rack and panel mount
Siemens FI 01 · 2012
5/157
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
HydroRanger Plus
See
Note 1
TEMP
Notes
RL5
RL4
See
Note 3
TRANS
See Note 2
RL3
RL2
RL1
Scope
Clock
connection module
–
Power
L1
+
L2/N
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
GND
9
shield
8
white/shield
7
shield
6
white/shield
5
–
black
4
+
sync
mA Out
3
mA In
2
–
shield
1
+
see
Note 4
EPROM
1. Required only if mounted adjacent to other Siemens Milltronics equipment.
Interconnect all ‘SYNC’ terminals with a single 18 AWG (0.5 mm 2) wire.
Voltage
Selection
Switch
2. Use RG-62 A/U coaxial (or equivalent) for extensions up to 365 m (1200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form ‘C’ (SPDT) contacts relay rated at 5 A 250 V AC,
non-inductive, when equal or lower rated limiting fuses are installed. Relay
de-energized when in alarm conditions and energized for pump control.
4. Before applying AC power (mains), ensure the correct voltage is selected.
Never operate the HydroRanger Plus with the ground (earth) wire disconnected.
5
HydroRanger Plus connections, wall mount
5/158
Siemens FI 01 · 2012
Terminal block
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LUC500
■ Overview
■ Application
It combines non-contacting ultrasonic technology, patented
echo-processing techniques and proven application software to
provide accurate level monitoring in liquids up to 15 m (50 ft).
It also effectively monitors flow in flumes, weirs and open channels. Five relays control any combination of pumps, gate valves
and alarms. Further advantages include fault signalling and data
logging for trend analysis. It can log the time, date and volume
of up to 20 occurrences of combined sewer overflows (CSO).
The basic device has 8 digital inputs, 5 digital outputs, 1 analog
input, 1 ultrasonic level point, differential/average capability and
one RS-232 interface with Modbus RTU/ASCII protocol.
The device can be expanded by additional I/Os, more RAM, two
channels, RS-485 or SmartLinx communications models as your
needs grow.
SITRANS LUC500 is a complete ultrasonic level controller for
monitoring and control of water distribution and wastewater
collection systems, with energy-saving algorithms.
■ Benefits
• Monitoring and control in one device
• Integral telemetry interface (Modbus RTU/ASCII)
• Patented algorithm for calculation of pumped volume within
5% accuracy
• Logging of pump runtime and number of pump starts
• Expandable with I/Os, RAM for data logging, dual point,
SmartLinx communications, and RS-485 interface
• Simple system configuration and diagnostics with
Siemens Dolphin Plus Windows-based software
• AC or DC power supply
• SITRANS LUC500 is available for rack mount, panel mount or
wall mount
It integrates seamlessly with SCADA or DCS systems or a PLC
system to provide remote access to all system parameters
(pumped volume, pump runtime, pump status). The integral telemetry interface (Modbus RTU/ASCII) allows remote control in
real time.
• Key Applications: wet well/lift station control, weirs/flumes,
open channels
Application of accessories
SITRANS LUC500 can be expanded to meet the requirements of
a variety of applications.
Auxiliary I/O cards, RAM and data logging, dual-channel function and SmartLinx communications.
• Input/output cards
A single auxiliary I/O card can be installed in the
SITRANS LUC500. The following I/O cards are available:
- 2 analog inputs/2 analog outputs
- 4 analog inputs
- 4 analog outputs
- 8 digital inputs
- 8 digital inputs/2 analog inputs/2 analog outputs
(wall mount only)
• Expanded memory card
The available RAM can be increased using this card. The data
logging function is then available.
• Two-channel function
A second measuring point is provided on the
SITRANS LUC500 to permit dual-channel measurements. This
function is made available by ordering a software access
code. Please contact your Siemens representative for details.
• Communications
The SITRANS LUC500 is offered with Modbus RTU/ASCII as a
standard feature. Further industrial communications protocols
are available with the addition of an optional SmartLinx card.
The following protocols are currently available:
- PROFIBUS DP
- Allen Bradley Remote I/O
- DeviceNet
Siemens FI 01 · 2012
5/159
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LUC500
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft)
Measuring points
1 or 2
Power supply
100 ... 230 V AC ± 15%,
50/60 Hz, 36 VA (17 W) or
12 ... 30 V DC, 20 W
Ultrasonic transducer
Compatible transducers:
ST-H and Echomax series
XPS-10/10F, XPS 15/15F, XCT-8,
XCT-12 and XRS-5
mA output signal
2-core copper conductor,
twisted, shielded,
0.5 ... 0.75 mm² (22 ... 18 AWG),
Belden 8760 or equivalent is
acceptable
Output
Ultrasonic transducer
44 kHz
Relays
5 relays, rated 5 A at 250 V AC,
non-inductive
• Wall Mount version:
4 SPST Form A relays,
1 SPDT Form C relay
• Rack and Panel Mount version:
4 SPST Form A relays,
1 SPST Form B relay
Accuracy
5
Displays and controls
Rack and panel mount
75 x 20 mm (3 x 0.8") LCD
(selectable backlighting)
Wall mount
100 x 40 mm (4 x 1.5") multfield
LCD, backlit
Error in measurement
0.25% of range or 6 mm (0.24"),
whichever is greater
Programming
Resolution
0.1% of measuring range or
2 mm (0.08"), whichever is
greater1)
Using removable handheld programmer (ordered separately) or
Dolphin Plus software (option)
Memory
Temperature compensation
-50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature
sensor (optional)
• Programmable fixed temperature
1 Mbyte RAM (static) with
battery, 1 Mbyte flash EPROM
Certificates and approvals
CE, FM, CSA
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure
-20 ... +50°C (-4 ... +122 °F)
Design
Rack mount
DIN 3 HU/21 pitch, 4-rail plug-in
unit suitable for standard
3 HU/84 pitch (19") rack
Panel mount
Suitable for standard panel
cutout DIN 43700 72 x 144 mm,
110 mm (4.33") center height
Weight (rack and panel mount)
1.5 kg (3.3 lbs)
Weight (wall mount)
2.5 kg (5.5 lbs)
Communications
RS-232
Siemens Dolphin protocol,
Modbus RTU and ASCII
Option
SmartLinx compatible, RS-485
5/160
Siemens FI 01 · 2012
1)
The measuring range corresponds to the distance from the zero point
to the sensor face, plus any range extension (P801)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LUC500
Optional Equipment
Order No.
L) 7ML5001SITRANS LUC500
A complete ultrasonic level controller for monitoring
7 7 7 77 - 77 A 7
and control of water distribution and wastewater
collection systems, with energy-saving algorithms.
Order No.
Handheld programmer
7ML1830-2AG
Mounting
Panel mount version
Rack mount version for 19" rack
Wall mount, standard enclosure
ERS500 Configuration Tool software, License only B) 7ML1930-1AF
1
2
3
Wall, 4 entry, M20 (valid with approval option 3 only)
5
Selection and Ordering data
Input voltage
100 ... 230 V AC
12 ... 30 V DC
ERS500 Configuration Tool software, demo CD only B) 7ML1930-1AG
A
B
Number of measurement points
Single point version
Dual point version
A
B
SmartLinx DeviceNet module
3
7ML1930-1AC
Sunshield kit, 304 SS (wall mount only)
7ML1930-1GA
Auxiliary Cards. Access code required1)
0
1
Auxilliary I/O
None
2 analog inputs and 2 analog outputs
4 analog inputs
A
B
C
Approvals
CSA, CE, UL (not available with mounting option 5)
CE
1 MB static RAM extended memory
L) PBD-51034040
2 analog input / 2 analog output for rack and
panel mount version
C) PBD-51034039
2 analog input / 2 analog output for wall mount
version
C) PBD-51034044
8 digital input for rack and panel mount version
C) PBD-51034042
8 digital input for wall mount version
C) PBD-51034043
4 analog input for rack and panel mount version
C) PBD-51034045
4 analog input for wall mount version
C) PBD-51034046
4 analog output for rack and panel mount version C) PBD-51034047
D
E
F
4 analog outputs
8 digital inputs
8 digital inputs, 2 analog inputs and 2 analog
outputs (only for wall mount)
4 analog output for wall mount version
C) PBD-51034048
8 digital inputs, 2 analog inputs, 2 analog outputs, C) PBD-51034272
wall mount
2
3
L) Subject to export regulations AL: N, ECCN: 3A991X.
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one
text line, suitable for enclosures
SITRANS RD500 web, datalogging, alarming,
K) 7ML5750ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1
Auxilliary memory
None
1 Mbyte static RAM, including data logging module
7ML1930-1FV
SITRANS RD200 Remote display - see Chapter 8
0
1
2
Protocol
Modbus RTU/ASCII
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
See SmartLinx product page 5/120 for more
information.
SITRANS RD100 Remote display - see Chapter 8
Data communications
SmartLinx ready, no module
SmartLinx PROFIBUS DP module
SmartLinx Allen-Bradley Remote I/0 module
Selection and Ordering data
ERS500 Configuration Tool software, CD, cable kit, B) 7ML1930-1AE
and License
Y15
Operating Instructions
Access code, dual point capability
C) 7ML1830-1KA
Auxiliary Cards2)
1 MB static RAM extended memory
L) 7ML1830-1KR
2 analog input / 2 analog output for rack and
panel mount version
C) 7ML1830-1KS
2 analog input / 2 analog output for wall mount
version
C) 7ML1830-1KT
8 digital input for rack and panel mount version
C) 7ML1830-1KU
8 digital input for wall mount version
C) 7ML1830-1LA
4 analog input for rack and panel mount version
C) 7ML1830-1LB
4 analog input for wall mount version
C) 7ML1830-1LC
English
7ML1998-5GL01
4 analog output for rack and panel mount version C) 7ML1830-1LD
German
Note: The Operating Instructions should be ordered
as a separate item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
7ML1998-5GL31
4 analog output for wall mount version
C) 7ML1830-1LE
8 digital inputs, 2 analog inputs, 2 analog outputs, C) 7ML1830-1LF
wall mount
1)
Other Operating Instructions
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
SmartLinx PROFIBUS DP, French
C) 7ML1998-1AQ13
Values of parameters P345 and P346 must be obtained from the customer
in order to generate the order for the access code.
2) For replacement of auxiliary card or spare auxiliary card. Access code not
required. Must be used only as replacement cards.
B) Subject to export regulations AL: N, ECCN: EAR99S.
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
L) Subject to export regulations AL: N, ECCN: 3A991X.
C) 7ML1998-1BH02
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the
order.
Siemens FI 01 · 2012
5/161
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LUC500
■ Dimensional drawings
Rack Mount Unit
18 (0.71)
176 (6.91)
3U
21 HP
Panel Mount Unit
104 (4.1)
72 (2.8)
195 (7.7)
144 (5.7)
152 (6.0)
5
11 (0.4)
terminal board extends
beyond panel faceplate
mounting bracket
hand tighten
(1 in. lb. torque max.)
Wall Mount Unit
102 (4.0)
209 (8.2)
285 (11.2)
28 (1.1)
267 (10.5)
172 (6.8)
mounting holes
(4 places)
SITRANS LUC500, dimensions in mm (inch)
5/162
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LUC500
■ Schematics
17
2
RELAY 2
18
33
3
RELAY 3
19
34
4
RELAY 4
20
5
RELAY 5
35
5
9
4
3
2
1
10
24 V 11
67
23
68
24
69
25
70
26
71
27 24 V
72
28
73
37
DCD
38
RXD
39
TXD
40
DTR
41
SG
42
DSR
43
RTS
44
CTS
29
45
SYNC
30
46
12
–
13
+
TS-3
mA I/P
+
14
SHIELD
SHIELD
15
–
–
31
47
16
+
+
32
48
2
1
–
66
100W
6
8
21
22
8
36
65
SEE SMARTLINX CARD
INSTRUCTION MANUAL
DIGITAL
INPUTS
6
7
7
RS232
RELAY 1
DIGITAL
INPUTS
1
SEE EXPANSION I/O CARD INSTRUCTION MANUAL
Rack and Panel Mount
49
50 See Note 2
51
52
53
54
55
56
57
58
AC Version
DC Version
61
46
46
62
47
L2/N
47
48
L1
48
59
60
–
12-30V
63
64
+
See Note 1
Notes
1. Transducer uses 2 wire twisted pair with shield only.
2. Terminals 49-64 are for use with optional expansion I/O cards.
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
Wall Mount
Optional mAInput card shown.
Other expansion cards I/O available see SITRANS LUC500 options list.
A B
A B
– + – +
– +
– +
RS-485
SMARTLINX
AC Version
DC Version
10
10
11
11
L2/N 12
100-230 V
L1 13
12-30 V
– 12
+ 13
SL1
SL2
SL3
SL4
SL5
SL6
SL7
SL8
SL9
SYNC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
TB3
TB4
7
8
DCD
RXD
TXD
DTR
SG
DSR
RTS
CTS
24 V
RS232
43 –
1
44 +
45 –
2
46 +
47
48 –
49 +
50
51 +
TS-3
52 –
53
54
1
55
2
56
3
57
4
58
27
28
29
30
31
32
33
34
35
36
37
38
39
6
40
5
41
42
24 V
TB1
TB2
SITRANS LUC500 connections
Siemens FI 01 · 2012
5/163
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU01 and LU02
■ Overview
■ Overview
The SITRANS LU01 is an ultrasonic long-range level controller
for liquids and solids in a single vessel up to 60 m (200 ft).
5
Handheld programmer shown is an accessory and must be
ordered separately.
■ Benefits
• Single point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all Echomax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus and SmartLinx compatible
• High/low alarms
■ Application
The system consists of a SITRANS LU01 monitor linked to a
non-contacting ultrasonic transducer that can be mounted up to
365 m (1200 ft) away. The SITRANS LU01 will measure distance,
level or volume, and it features patented Sonic Intelligence echo
processing software for superior reliability.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
An on-board communications port automatically configures for
RS-232, RS-485 or bi-polar current loop. The SITRANS LU01 will
connect to a DCS or PLC using Siemens SmartLinx interface
modules, giving you remote 2-way communication and full parameter access.
Modules for popular industrial buses can be factory installed or
added later to meet changing needs. No external gateway is
required, reducing hardware and cabling costs.
• Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets
5/164
Siemens FI 01 · 2012
The SITRANS LU02 is a dual point ultrasonic long-range level
controller for liquids and solids in one or two vessels up to 60 m
(200 ft).
Handheld programmer shown is an accessory and must be
ordered separately.
■ Benefits
• Dual point, long-range level monitoring
• Easy to install; easy to program using removable infrared
keypad (optional)
• Compatible with all Echomax transducers
• Backlit LCD display with reading in standard engineering units
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus and SmartLinx compatible
• High/low alarms
■ Application
SITRANS LU02 will measure liquids, solids or a combination of
both in one or two vessels of different sizes, shapes and configurations up to 60 m (200 ft).
The system uses ultrasonic technology to measure level, space,
distance, volume or average/differential. It features patented
Sonic Intelligence echo processing software for superior reliability. Transducers can be mounted up to 365 m (1200 ft) from the
monitor.
Readings are displayed in user-selectable linear engineering
units on the backlit LCD.
It features an onboard communications port that automatically
configures for RS-232, RS-485 or bi-polar current loop. It will
connect to a DCS or PLC using Siemens SmartLinx interface
modules, giving you remote 2-way communication and full
parameter access. Modules for popular industrial buses can
be factory installed or added later to meet changing needs.
No external gateway is required, reducing hardware and cabling
costs.
• Key Applications: chemical storage, liquid storage, bulk solids storage (gravel, flour bins, grains, cereals), plastic pellets,
tripper car
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU01 and LU02
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 60 m (1 ... 200 ft)
Measuring points
SITRANS LU01: Max. one point;
SITRANS LU02 Max. two points
AC model
100/115/200/230 V AC ± 15%,
50/60 Hz, 31 VA
DC model
18 ... 30 V DC, 25 W
Displays and controls
51 x 127 mm (2 x 5") graphics
LCD with backlighting
Memory
EEPROM (non-volatile), no
backup battery required
Programming
Using removable programmer
(ordered separately) or
Dolphin Plus (option)
Certificates and approvals
CE, CSAUS/C, FM, ATEX II 3D
Lloyd's register of Shipping
(Categories ENV1, ENV2,
ENV3 and ENV5)
Output signal
Ultrasonic transducer
Echomax series,
ST-H transducers
Relays
4 SPDT Form C relays, rated at
5 A at 250 V AC, resistive load
mA output
0/4 ... 20 mA, optically isolated
• Max. load
750 Ω, isolated, 30 V
• Resolution
0.1 % of range
• Outputs
SITRANS LU01:
Max. one mA output
SITRANS LU02:
Max. two mA outputs
Accuracy
Error in measurement
0.25% of range or 6 mm (0.24"),
whichever is greater
Resolution
0.1% of measuring range or 2 mm
(0.08"), whichever is greater
Temperature compensation
-50 ... +150 ºC (-58 ... +302 ºF)
• Integral temperature sensor
• External TS-3 temperature
sensor (optional)
• Programmable fixed temperature
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure
-20 ... +50 ºC (-4 ... +122 ºF)
Design
Weight
2.7 kg (6 lbs)
Material (enclosure)
Polycarbonate
Degree of protection (wall mount)
IP65
Electrical connection
Ultrasonic transducer cable
extension
RG62-A/U coaxial cable with low
capacitance
mA output signal
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
Electrical connection and relay
connection
Copper conductor according to
local requirements, rated 250 V
5A
Synchronization
Up to 16 LU01/LU02 units can be
synchronized together
Options
External temperature sensor
TS-3
Communications
• SmartLinx: protocol-specific
modules as interface for popular
industrial fieldbus systems
• Dolphin Plus: Siemens
Windows-compatible interface
and ComVerter link (infrared)
Order No.
Selection and Ordering data
SITRANS LU01/LU02
Single or dual point ultrasonic long-range level
monitoring system for liquids and solids, and
ranges up to 60 m (200 ft).
Number of measuring points
LU01 version, 1 point
LU02 version, 2 points
C) 7ML5004-
77 7 77 - 77
1
2
Input voltage
100/115/200/230 V AC, voltage selector switch
18 ... 30 V DC
Feature software
Standard
A
B
A
Application software
Standard
1
Data communications
No module (SmartLinx ready)
SmartLinx Allen-Bradley Remote
I/O module
SmartLinx PROFIBUS DP module
0
1
2
3
SmartLinx Modbus RTU module
Enclosure
Wall mount
Wall mount, drilled, 6 x M20
1
3
Approvals
CE, CSAUS/C, FM1)
CE2)
ATEX II 3D1)
1)
2)
A
B
C
Available with enclosure option 1 only
Available with enclosure option 3 only
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/165
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU01 and LU02
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Operating Instructions
SITRANS LU01
Order No.
English
C) 7ML1998-5BE02
French
C) 7ML1998-5BE12
German
C) 7ML1998-5BE32
SITRANS LU02
C) 7ML1998-5BD02
French
C) 7ML1998-5BD12
C) 7ML1998-5BD32
German
Note: The Operating Instructions should be
ordered as a separate line item.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
Handheld programmer
7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosures
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
TS-3 Temperature Sensor - see TS-3 on page 5/200
7ML1830-2AN
Sunshield kit, 304 SS
7ML1930-1GA
Spare parts
Card, LU01 mother main, AC, comm ready
C) 7ML1830-1KX
Card, LU02 mother main, AC, comm ready
C) 7ML1830-1MA
Card, LU02 daughter, comm ready
C) 7ML1830-1LP
Card, LU01 daughter, comm ready
C) 7ML1830-1LN
Card, display
See SmartLinx product page 5/120 for more
information.
C) 7ML1830-1LQ
C) Subject to export regulations AL: N, ECCN: EAR99.
Other Operating Instructions
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
SmartLinx PROFIBUS DP, French
C) 7ML1998-1AQ12
SmartLinx Modbus, English
C) 7ML1998-1BF01
SmartLinx Modbus, German
C) 7ML1998-1BF31
C) 7ML1998-1BG01
SmartLinx Modem, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the
order.
■ Dimensional drawings
106
(4.2)
92
(3.6)
285 (11.2)
267 (10.5)
2
3
267 (10.5)
100
%
209 (8.2)
1
4
0
1
2
3
4
5
6
7
8
9
0
P
P
mA
C
XX
1
2
3
1
2
3
5
6
7
8
9
0
P
P
mA
4
XX
%
SITRANS LU 02
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
Dimensional drawings for SITRANS LU01 (left) and SITRANS LU02 (right), dimensions in mm (inch)
Siemens FI 01 · 2012
0
C
SITRANS LU 01
5/166
100
4
%
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure
rating.
106
(4.2)
92
(3.6)
285 (11.2)
172 (6.8)
209 (8.2)
%
172 (6.8)
5
English
Accessories
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU01 and LU02
■ Schematics
AC Model
17
18
19
20
21
22
23
24
25
26
2
3
4
Relay
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS-232
B A
32
33
SYNC
16
1
1
2
Temp. Temp.
sensor sensor
2
15
SHLD
14
COM
13
SHLD
1
Note 1
12
COM
mA
Outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
34
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 VAC
Operation
(50/60 Hz
31 VA)
RS-485
DC Model
17
18
19
20
21
22
23
24
25
26
2
3
4
Relay
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
16
1
1
2
Temp. Temp.
sensor sensor
2
15
SHLD
14
SHLD
13
COM
1
Note 1
12
COM
mA
Outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
RS-232
B A
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
34
35
36
37
–
+
24 V
5
RS-485
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5mm2) wire.
SITRANS LU01 connections
AC Model
17
18
19
20
21
22
23
24
25
26
2
3
4
Relay
Note 3
27
1
28
2
TX
Note 2
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
RS-232
B A
32
33
SYNC
16
1
1
2
Temp. Temp.
sensor sensor
2
15
SHLD
14
COM
13
SHLD
1
Note 1
12
COM
mA
Outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
34
35
36
37
L2/N L1
Position SW1
for 100/115/
200/230 VAC
Operation
(50/60 Hz
31 VA)
RS-485
DC Model
2
1
2
Temp. Temp.
sensor sensor
16
17
18
19
20
21
22
23
24
25
26
1
2
3
Relay
Note 3
Note 2
4
27
1
28
2
TX
29
30
31
1
2
RX
Bi-polar current loop
TX
RX
32
33
SYNC
15
SHLD
14
SHLD
1
13
COM
Note 1
12
COM
mA
Outputs
11
SHLD
2
10
SHLD
1
9
SHLD
–
8
SHLD
+
7
BLK
–
6
WHT/SHLD
+
5
BLK
4
BLK
WHT/SHLD
3
WHT/SHLD
BLK
2
WHT/SHLD
Note 4
1
RS-232
B A
34
35
36
37
–
+
24 V
RS-485
Notes:
1. Optically isolated, 750 Ω max. load
2. Use RG62-A/U coaxial (or equivalent) for extensions up to 365 m (1200 ft).
Run in grounded metal conduit, separate from other wiring.
3. Each relay has 1 set of Form 'C' (SPDT) contacts, relay rated at 5 A 250 V AC, non-inductive, when equal or lower rated
limiting fuses are installed.
4. Required if mounted adjacent to other SITRANS LU01 units or other specified Siemens Milltronics devices. Interconnect
all 'SYNC' terminals with a single 18 AWG (0.5mm2) wire.
SITRANS LU02 connections
Siemens FI 01 · 2012
5/167
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU10
■ Overview
■ Benefits
• Ten point, long-range level monitoring
• Automatic level-to-volume conversion for standard or custom
tank shapes
• Dolphin Plus and SmartLinx compatible
• Backlit LCD display with reading in standard engineering units
• Easy to install, easy to program using removable infrared
keypad (optional)
■ Application
It can be used in a wide range of applications to scan liquids,
solids or a combination of both contained in vessels of differing
size, shape, and configuration up to 60 m (200 ft).
SITRANS LU10 is an ultrasonic long-range level monitor for
liquids and solids, offering 10-point monitoring in a single unit.
5
Handheld programmer shown is an accessory and must be
ordered separately.
5/168
Siemens FI 01 · 2012
SITRANS LU10 uses ultrasonic technology to measure level,
space, distance, volume, or average/differential. Transducers
can be mounted up to 365 m (1200 ft) from the monitor.
The SITRANS LU10 features patented Sonic Intelligence echo
processing software for superior reliability. Readings are displayed in user-selectable linear engineering units on the LCD.
SITRANS LU10 will connect to a DCS or PLC using
Siemens SmartLinx interface modules, giving you remote
2-way communication and full parameter access. Modules for
popular industrial buses can be factory installed or added later
to meet changing needs. No external gateway is required,
reducing hardware and cabling costs.
• Key Applications: chemical storage, liquid storage, bulk solids storage (sugar, flour bins, grains, cereals), plastic pellets,
tank farms
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU10
■ Technical specifications
Power supply
100/115/200/230 V AC ± 15%,
50/60 Hz, 31 VA
Displays and controls
51 x 127 mm (2 x 5") graphics
LCD with backlighting
Max. 10
Memory
EEPROM (non-volatile),
no backup battery required
Ultrasonic transducer
Echomax series,
ST-H transducers
Programming
Relays
• SITRANS LU SAM module
(option): 20 alarm/control relays
• SPDT Form C relays, rated 5 A at
250 V AC, resistive load
Using removable programmer
(ordered separately) or
Dolphin Plus (option)
Certificates and approvals
mA output
SITRANS LU A0 module (option):
0/4 ... 20 mA, optically isolated
• CE, C-TICK, FM, CSAUS/C ,
ATEX II 3D
• Lloyd's register of Shipping
(Categories ENV1, ENV2, ENV3
and ENV5)
• Max. load
750 Ω, isolated
• Resolution
0.1 % of range
Mode of operation
Measuring principle
Ultrasonic level measurement
Measuring range
Max. 0.3 ... 60 m (1 ... 200 ft)
Measuring points
Output
Accuracy
Error in measurement
0.25 % of range or 6 mm (0.24"),
whichever is greater
Resolution
0.1% of measuring range or 2 mm
(0.08"), whichever is greater
Temperature compensation
-50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature
sensor (expandable to 10 inputs
with optional TIB-9 card)
• Programmable fixed temperature
Options
Expansion card
TIB-9, increases the number of
TS-3 inputs from 1 to10
• External temperature sensor
• Communications
TS-3
• SmartLinx: protocol-specific
modules as interface for popular
industrial fieldbus systems
• Dolphin Plus: Siemens
Windows-compatible interface
and ComVerter link (infrared)
• Max. 3 I/O devices per
SITRANS LU10
• SITRANS LU AO analog output
module (max. 1)
• SITRANS LU SAM, satellite
alarm module (max. 2)
• I/O devices
Rated operating conditions
Ambient conditions
Ambient temperature for enclosure
-20 ... +50 °C (-4 ... +122 °F)
Design
Weight
2.7 kg (6 lbs)
Material (enclosure)
Polycarbonate
Degree of protection (wall mount)
IP65/Type 4X/NEMA 4X
Electrical connection
Ultrasonic transducer
RG62-A/U coaxial cable with low
capacitance
Signal transmission
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
Electrical connection and relay
connection
Copper conductor according to
local requirements,
rated 250 V 5 A
Synchronization
Up to 16 LU10 units can be
synchronized together
Siemens FI 01 · 2012
5/169
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU10
Selection and Ordering data
SITRANS LU10
Ten point ultrasonic long-range level monitoring
system for liquids and solids applications, and
ranges up to 60 m (200 ft).
Input voltage
100/115, 200/230 V AC, selectable
Feature software
Standard
Application software
Standard
2)
Available with Enclosure option 1 only
Available with Enclosure option 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
Y15
Order No.
Operating Instructions
A
A
3
1)
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
SmartLinx Modbus RTU module
Approvals
CE, CSAUS/C, FM1)
ATEX II 3D1)
CE, C-TICK2)
Further designs
1
0
1
2
Enclosure
Wall mount
Wall mount, drilled, 12 x M20
Order code
Selection and Ordering data
7 7 7 7 7 - 77
Data communications
No module (SmartLinx ready)
SmartLInx Allen-Bradley Remote I/O module
SmartLinx PROFIBUS DP module
TIB-9 temperature card
None
With TIB-9 card
5
Order No.
C) 7ML5007-
English
C) 7ML1998-5AN02
French
C) 7ML1998-5AN12
German
C) 7ML1998-5AN32
Other Operating Instructions
0
1
1
2
A
B
D
SmartLinx Allen-Bradley Remote I/O, English
C) 7ML1998-1AP03
SmartLinx PROFIBUS DP, English
C) 7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
C) 7ML1998-1AQ33
SmartLinx Modbus, English
C) 7ML1998-1BF01
SmartLinx Modbus, German
C) 7ML1998-1BF31
C) 7ML1998-1BG01
SmartLinx Modem, English
Note: The appropriate SmartLinx Operating Instructions should be ordered as a seperate line on the
order.
Accessories
Handheld programmer
7ML1830-2AN
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosures
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
TS-3 Temperature Sensor see TS-3 on page 5/200
7ML1830-2AN
Sunshield kit, 304 SS
7ML1930-1GA
Spare parts
Card, mother main, AC, comm ready
C) 7ML1830-1ML
Card, daughter, comm ready
C) 7ML1830-1LY
Card, display
See SmartLinx product page 5/120 for more information.
C) Subject to export regulations AL: N, ECCN: EAR99.
5/170
Siemens FI 01 · 2012
7ML1830-1LQ
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU10
■ Dimensional drawings
106
(4.2)
92
(3.6)
285 (11.2)
267 (10.5)
1
2
3
4
5
6
7
8
9
100
10
172 (6.8)
209 (8.2)
%
0
1
2
3
5
6
7
8
9
0
P
P
mA
C
4
XX
%
SITRANS LU 10
Mounting hole
4.3 (0.17) diameter
access under lid
(4 places)
Suitable location for conduit entrances. Use
water-tight conduit hubs to maintain enclosure rating.
SITRANS LU10, dimensions in mm (inch)
9
10
transducers
Note 1
To transducers (10 max.) RG62-A/U
coax, 365 m / transducer max.
black
white/shield
black
white/shield
23 24 25 26
Temp.
sensor
5
10
black
white/shield
9
36 37 38 39 40
41 42 43 44 45 46 47 48 49 50 51 52
SYNC
2
black
1
3
white/shield
18 19 20 21 22
black
white/shield
4
black
white/shield
3
black
white/shield
2
black
white/shield
1
2
black
white/shield
■ Schematics
1
2
TX
1
2
RX
Peripheral
communication
2
3
9
10
L2/N L1
P12
V
Note 3
Note 2
Position SW1
for 100/115/
200/230 V
AC
Operation
(50/60 Hz,
15 VA)
Notes:
1. Transducer cables must be run in a grounded metal conduit separate from other wiring (except TS-3 temperature sensor wiring, if
applicable).
2. Optional TIB-9 card for multiple temperature sensors. Do not jump the terminals if TS-3s are not used.
3. The SITRANS LU10 is compatible with the following Siemens Milltronics peripherals:
- SITRANS LU SAM - relay satellite alarm module
- SITRANS LU AO - analog output module
SITRANS LU10 connections
Siemens FI 01 · 2012
5/171
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU SAM
■ Overview
■ Technical specifications
Mode of operation
Input
Communications
Data from SITRANS LU10
Transmission rate
4800 bits/s
Voltage
± 20 mA bipolar current loop
Output
Relays
20 multi-purpose relays, programmable from SITRANS LU10
SPDT Form C relays, rated 5 A at
250 V AC, resistive load
± 20 mA bipolar current loop
Input and transmission
• Max. load
1 receiving unit
Rated operation conditions
Ambient conditions
5
SITRANS LU SAM Satellite Alarm Module provides up to 20 relay
outputs for the measurement points of the SITRANS LU10 level
monitor.
■ Benefits
Ambient temperature
-20 ... +50 °C (-5 ... +122 °F)
Location
Indoor/outdoor
Installation category
II
Pollution degree
4
Design
• The SITRANS LU SAM can be located up to 1500 m (5000 ft)
from the SITRANS LU10
• Relay outputs can be assigned to any point on the
SITRANS LU10
Weight
3 kg (6.6 lbs)
Material (enclosure)
Polycarbonate
Degree of protection
Type 4X/NEMA 4X/IP65
Cable connection
2 copper conductors, twisted,
with foil shield/drain wire, 300 V
0.5 ... 0.75 mm² (22 ... 18 AWG)
The operation of the SITRANS LU SAM is programmed via the
SITRANS LU10. The only on-board settings are for bank selection and output testing.
Electrical connection and relay
connection
Copper conductor according to
local requirements,
rated 250 V 5 A
Using a SITRANS LU SAM, you can have two relay outputs for all
ten measurement points, all 20 for a single measurement point
or any combination between the two.
Power supply
100/115/200/230 V AC ± 15%,
50/60 Hz, 20 VA
Displays and controls
1 LED for display of voltage/communications state, 20 LEDs for
display of relay states
Certificates and approvals
CE, FM, CSAUS/C, C-TICK
■ Application
All relays are Form C to allow NO or NC wiring.
Selection and Ordering data
SITRANS LU SAM
Satellite alarm module provides up to 20 relay
outputs for the measurement points of the
SITRANS LU10 level monitor.
Approvals: CSAUS/C, FM, CE, C-TICK
Order No.
C) 7ML5811-1A
Operating Instructions
English
C) 7ML1998-5CF02
C) 7ML1998-5CF32
German
Note: Operating Instructions should be ordered as
a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete Quick Start and
Operating Instructions library.
C) Subject to export regulations AL: N, ECCN: EAR99.
5/172
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU SAM
■ Dimensional drawings
209
(8.2)
16
(0.6)
91
(3.6)
Lid screws
(6 places)
172
(6.8)
285
(11.2)
SITRANS LU SAM
Suitable location for
Mounting holes
conduit entrances
(accessed under lid)
4.3 mm (0.17") diameter
4 places
267
(10.5)
Lid
Enclosure
Mounting screw (by customer)
5
SITRANS LU SAM, dimensions in mm (inch)
■ Schematics
1
Receiver spare 2
3
4
Note 1
5
Receiver
6
spare 7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Note 2 23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
Note 3
1
L1
L2/N 2
3
1
11
2
12
3
13
4
14
5
15
6
16
7
17
8
18
9
19
10
20
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
200V
100/115/
200/230 Vac
50/60 Hz select
voltage via switch 230V
OFF
115V
100V
SW1
Switch is shown in OFF position.
Select appropriate voltage.
Notes:
1. SITRANS LU SAM receiver is polarized.
2. Refer to associated application device instruction manual for wiring detail.
Check that the communication parameter P740 (SITRANS LU10) is 'ON'.
3. If SITRANS LU SAM is unpowered, transmitter ceases communication to all
downstream peripherals.
4. Relay contact Form 'C' SPDT, 5A at 250 V AC non-inductive (typical of up to 20
per SITRANS LU SAM).
SITRANS LU SAM connections
Siemens FI 01 · 2012
5/173
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU AO
■ Overview
■ Technical specifications
Mode of operation
Input
Communications
• Transmission rate
• Voltage
• Polarization
• Max. load
Data from SITRANS LU10
4800 bits/s
± 20 mA bipolar current loop
Non-polarized
1 receiving unit
Output
Analog outputs
• ± 20 mA bipolar current loop
- Max. load
- Resolution
10 analog outputs, programmable
from SITRANS LU10
0 or 4 ... 20 mA, isolated
Input and transmission
750 Ω
0.1%
Rated operating conditions
5
The SITRANS LU AO Analog Output Module provides remote
analog output for the measurement points of the SITRANS LU10
level monitor.
■ Benefits
Ambient conditions
• Ambient temperature for enclosure
• Location
• Installation category
• Pollution degree
-20 ... +50 °C (-5 ... +122 °F)
Indoor/outdoor
II
4
Design
• Analog outputs can be up to 1500 m (5000 ft) from the
SITRANS L 10
• Analog outputs can be per transducer and/or average of 2 or
more
■ Application
The operation of the SITRANS LU AO is programmed via the
SITRANS LU10. The only on-board settings are for bank selection and output testing.
The SITRANS LU AO can provide up to 10 analog outputs (each
sharing a common negative bus which is electrically isolated
from ground).
Weight
2 kg (4.4 lbs)
Material (enclosure)
Polycarbonate
Degree of protection
• Cable connection
Type 4X/NEMA 4X/IP65
2 copper conductors, twisted,
with foil shield/drain wire, 300 V
0.5 ... 0.75 mm² (22 ... 18 AWG)
Copper conductor according to
local requirements,
rated 250 V 5 A
• Electrical connection and
relay connection
Power supply
100/115/200/230 V AC ± 15%,
50/60 Hz, 15 VA
Displays and controls
1 LED for display of voltage/
communications state
Certificates and approvals
CE, FM, CSAUS/C , C-TICK
Selection and Ordering data
SITRANS LU AO
Provides remote analog output for the measurement points of the SITRANS LU10 level monitor.
Approvals: CSAUS/C, FM, CE, C-TICK
Order No.
C) 7ML5810-1A
Operating Instructions
English
C) 7ML1998-5CE01
C) 7ML1998-5CE31
German
Note: Operating Instructions should be ordered as a
separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete Quick Start and
Operating Instructions library.
C) Subject to export regulations AL: N, ECCN: EAR99.
5/174
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic controllers
SITRANS LU AO
■ Dimensional drawings
209
(8.2)
16
(0.6)
91
(3.6)
Lid screws
(6 places)
172
(6.8)
285
(11.2)
SITRANS LU AO
267
(10.5)
Lid
Suitable location for
Mounting holes
conduit entrances
(accessed under lid)
4.3 mm (0.17") diameter
4 places
Enclosure
5
Mounting screw (by customer)
SITRANS LU AO, dimensions in mm (inch)
■ Schematics
230V
200V
OFF
Switch is shown in OFF position.
Select appropriate voltage.
115V
100V
See note 1
mA
output
spare
Bi-polar
Receiver
1
2
3
SW3
See note 2
4
+
1_
5
6
7
mA
output
+
2_
8
9
+
3_
+
mA
output
4_
+
5_
mA
output
+
6_
+
7_
mA
output
+
8_
+
9_
+
10_
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
L2
/N L1
30 31 32
See note 3
Isolated 0/4 to 20 mA out,
750 ohm load max. (typical of 10)
100/115/200/230 V AC
50/60 Hz select
voltage via switch
Notes:
1. SITRANS LU AO receiver input is non-polarized.
2. Refer to associated application device instruction manual for wiring detail. Check that the communication parameter P740 (SITRANS LU10) is ON.
3. SITRANS LU AO interconnecting cable shield should be grounded at SITRANS LU10 only. Insulate shields at junctions to prevent inadvertant
grounding. Maximum individual loop length is 3000 m (10 000 ft).
SITRANS LU AO connections
Siemens FI 01 · 2012
5/175
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Ultrasonic transducers
■ Overview
Ultrasonic Transducers
Ultrasonic measuring systems are the cost-effective choice for
monitoring and control in short- to long-range applications for
liquids, slurries, and solids in a wide range of industries. Transducers are impervious to dust, moisture, corrosion, vibration,
flooding, and extreme temperature. They are easy to install and
virtually maintenance-free. Choose from a wide selection of
models designed for short or long range applications on liquids
or solids.
■ Technical specifications
Echomax Transducers
Liquids
Liquids and Solids
Solids
Standard
XRS-5
5
High Temperature
High Temperature
ST-H
XPS-10
XPS-15
XPS-30
XPS-40
XCT-8
XCT-12
XLT-30
XLT-60
Max. range 1) 8 m
(26 ft)
10 m
(33 ft)
10 m
(33 ft)
15 m
(50 ft)
30 m
(100 ft)
40 m
(130 ft)
8m
(26 ft)
12 m
(40 ft)
30 m
(100 ft)
60 m
(200 ft)
Min. range
0.3 m
(1 ft)
0.3 m
(1 ft)
0.3 m
(1 ft)
0.3 m
(1 ft)
0.6 m
(2 ft)
0.9 m
(3 ft)
0.6 m
(2 ft)
0.6 m
(2 ft)
0.9 m
(3 ft)
1.8 m
(6 ft)
Max. temperature
+65 °C
(+149 °F)
+73 °C
(+164 °F)
+95 °C
(+203 °F)
+95 °C
(+203 °F)
+95 °C
(+203 °F)
+95 °C
(+203 °F)
+145 °C
(+293 °F)
+145 °C
(+293 °F)
+150 °C
(+300 °F)
+150 °C
(+300 °F)
Min. temper- -20 °C
ature
(-4 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
-40 °C
(-40 °F)
Typical
Wet wells
Applications and open
channels
Chemical
Dusty solids Deep wet
storage and and slurries wells and
liquid tanks
solids
Powders,
pellets and
solids
Powders,
pellets and
solids
Hot acids
Hot acids
Clinker and Clinker and
and slurries, and slurries coal buncoal bunfood
kers
kers
44 kHz
44 kHz
44 kHz
30 kHz
22 kHz
44 kHz
44 kHz
22 kHz
13 kHz
12°
12°
6°
6°
6°
12°
6°
5°
5°
R 1"
[(BSPT),
EN 10226]
1" NPT
R 1"
[(BSPT),
EN 10226]
1" NPT
R 1.5"
[(BSPT), EN
10226]
Universal
thread
1.5" NPT
R 1.5"
[(BSPT),
EN 10226]
Universal
thread
1.5" NPT
R 1"
[(BSPT),
EN 10226]
1" NPT
R 1"
[(BSPT),
EN 10226]
1" NPT
1” NPT
1” NPT
• Aluminum
• 304 Stainless steel
• Polyester
• Silicone
• Aluminum
• 304 Stainless steel
• Polyester
• Silicone
•
•
Frequency
44 kHz
Beam angle 10°
(-3dB)
Thread size R 1" [(BSPT), 1" and 2"
EN 10226] NPT R 2"
1" NPT
[(BSPT),
EN 10226],
2" [(BSPP),
EN ISO
228-1]
Enclosure
• PVDF
• ETFE
Copolymer • Option:
• CSM
PVDF
• Option:
Flange
with PTFE
facing
• PVDF
• PVDF
• PVDF
• PVDF
• Option:
• Option:
• Option:
• Option:
Foam
Foam
Foam
Foam
facing
facing
facing
facing
• Flange
• Flange
• Flange
with PTFE
with PTFE
with PTFE
facing
facing
facing
• PVDF
• PVDF
• Option:
• Option:
Flange
Flange
with PTFE
with PTFE
facing
facing
• Sanitary
version
Compatible
with:
SITRANS LU
•
•
•
•
SITRANS
LUC500
•
•
•
Hydro
Ranger 200
•
•
MultiRanger
100/200
•
•
OCM III
•
1)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Application conditions such as extreme dust or angle of repose may reduce the usable maximum range.
Consult your local Siemens representative for further information.
5/176
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
ST-H
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
0.3 ... 10 m (1 ... 33 ft)
Output
Frequency
44 kHz
Beam angle
12°
Accuracy
Temperature compensation
Compensated by integral
temperature sensor
Rated operating conditions
Pressure
Normal atmospheric pressure
Ambient conditions
• Ambient temperature
ST-H transducers use ultrasonic technology to measure level in
chemical storage and liquid tanks.
■ Benefits
-20 ... +60 °C (-5 ... +140 °F)
(ATEX approved model)
-40 ... +73 °C (-40 ... +163 °F)
(CSA/FM approved model)
Design
5
Weight 1)
1.4 kg (3 lbs)
Material (enclosure)
Base and lid made of ETFE or
PVDF (epoxy fitted joint)2)
Process connection
2" NPT [(Taper), ANSI/ASME
B1.20.1], R 2" [(BSPT),
EN 10226] or G 2" [(BSPP),
EN ISO 228-1]
The narrow design of the ST-H allows the transducer to be
mounted on a 2" (50.8 mm) standpipe. When mounted correctly,
it is completely protected from the process and can even be
used in harsh, corrosive environments.
Degree of protection
IP68
Cable connection
2-core shielded/twisted,
0.519 mm² (20 AWG),
PVC sheath
During operation, the ultrasonic transducer emits acoustic
pulses in a narrow beam perpendicular to the transducer face.
The level transceiver measures the propagation time between
pulse emission and reception of the echo to calculate the distance from the transducer to the material. Variations in sound
velocity due to changes in temperature within the permissible
range are automatically compensated by the integral temperature sensor.
• Key Applications: chemical storage, liquid tanks
Cable (max. length)
365 m (1200 ft) with RG 62 A/U
coaxial cable
• Can be mounted on a 2" (50.8 mm) standpipe
• Immune to corrosive and harsh environments
• Integral temperature sensor
■ Application
Options
Flange adapter
3" Universal (fits DN 65, PN 10
and 3" ASME)
Certificates and approvals
CE3), CSA Class I, II, III, Div. 1,
Gr. A, B, C, D, E, F, G T3
(ETFE only), FM Class I, II, Div. 1,
Gr. C, D, E, F, G T4A,
ATEX II 2G EEx m IIC T5,
C-TICK, INMETRO:
Br-Ex m II T5
1)
Approximate shipping weight of transducer with standard cable length
When measuring chemicals, check compatibility of ETFE or PVDF and
epoxy, or mount joint external to process.
3)
EMC certificate available on request
2)
Siemens FI 01 · 2012
5/177
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
ST-H
Selection and Ordering data
Order No.
C) 7ML1100Echomax ST-H ultrasonic transducer
Level measurement in chemical storage and liquid
77A 7 0
tanks. The narrow design of the ST-H allows the
transducer to be mounted on a 2" standpipe.
Measuring range: min. 0.3 m (1 ft), max. 10 m
(33 ft).
Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
ETFE, R 2" [(BSPT), EN 10226]
ETFE, G 2" [(BSPP), EN ISO 228-1]
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME
B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1]
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
50 m (164.04 ft)
100 m (328.08 ft)
5
Approvals
FM Class I, II, Div. 1, C-TICK
ATEX II 2G, CSA, C-TICK, INMETRO 1)
ATEX II 2G, C-TICK, INMETRO 2)
0
1
2
3
4
5
A
B
C
D
E
2
3
4
Operating Instructions
Quick Start Manual, multi-language
7ML1998-5QK82
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
1)
Available with Process connection options 0 to 2 only
Available with Process connection options 3 to 5 only
C) Subject to export regulations AL: N, ECCN: EAR99.
2)
5/178
Siemens FI 01 · 2012
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75")]: Measuring-point number/identification (max. 16 characters) specify in plain text
Y17
Accessories
Order No.
Universal box bracket, mounting kit
7ML1830-1BK
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE flange
adapter for 2" BSPT
7ML1830-1BU
Easy Aimer 2, NPT with ¾" x 1" PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
ST-H
■ Dimensional drawings
1" NPT
conduit thread
20.9
(0.82)
74 (2.9)
mounting thread
(process
connection)
119 (4.7)
22
(0.87)
Flange Adapter
coupling
Siemens Milltronics
flange adapter
82 (3.2)
87 (3.4)
diameter
ST-H ultrasonic transducer, dimensions in mm (inch)
■ Schematics
5
Direct connection
Black
White
Shield
Coaxial extension
White
Shield
3 Terminal direct*
Black
White
Shield
3 Terminal extension*
Black
White
Shield
* For SITRANS LUC500, MultiRanger 100/200, HydroRanger 200
ST-H ultrasonic transducer connections
Siemens FI 01 · 2012
5/179
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XRS-5
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
0.3 ... 8 m (1 ... 26 ft), dependent
on application
Output
Frequency
44 kHz
Beam angle
10°
Accuracy
Temperature error
Compensated by integral
temperature sensor
Rated operating conditions
5
Echomax XRS-5 ultrasonic transducer provides reliable,
continuous level monitoring of liquids and slurries in narrow
lift stations/wet wells, flumes, weirs and filter beds using a
beam angle of just 10° and a CSM rubber face.
■ Benefits
• Narrow beam angle of only 10°
• Chemically resistant PVDF copolymer enclosure and CSM
rubber face
• Measuring range: 8 m (26 ft) for measurement of liquids and
slurries
• Fully submersible: IP68 degree of protection
• Easy installation with 1" NPT or R 1" BSPT connection
Vessel pressure
Normal atmospheric pressure
Ambient conditions
• Ambient temperature
-20 ... +65 °C (-4 ... +149° F)
Design
Weight (approximate shipping
weight of sensor with standard cable
length)
1.2 kg (2.6 lbs)
Material (enclosure)
PVDF copolymer enclosure and
CSM face
Process connection
1" NPT [(Taper),
ANSI/ASME B1.20.1] or R 1"
[(BSPT), EN 10226]
Degree of protection
IP65/IP68
Cable connection
2-core shielded/twisted,
0.5 mm2 (20 AWG), PVC sheath
Cable (max. length)
• 365 m (1200 ft) with
RG 62 A/U coaxial cable
• 365 m (1200 ft) with 2-core
twisted pair, foil shield, 0.5 mm2
(20 AWG), PVC sheath, only for
SITRANS LUC500,
MultiRanger 100/200
■ Application
The XRS-5 is non-contacting with a measuring range from
0.3 to 8 m (1 to 26 ft). Advanced echo processing ensures reliable data even in conditions with obstructions, turbulence and
foam.
The hermetically sealed CSM rubber face and the PVDF copolymer enclosure are designed for maximum resistance to methane, salt water, caustics and harsh chemicals common to wastewater installations. With an IP68 degree of protection, this
rugged sensor is fully submersible in the event of flood conditions. Use a submergence shield if full submergence is possible
in the application. A submergence shield will maintain a high
level reading output during submerged conditions.
The low-cost XRS-5 transducer is compatible with a full range
of Siemens controllers, from a basic system for high/low alarm
or simple pump control, up to advanced control systems with
communications, telemetry and SCADA integration capabilities.
• Key Applications: wet wells, flumes, weirs, filter beds
5/180
Siemens FI 01 · 2012
Options
Flange version
Factory flange with PTFE face for
ASME, EN or JIS configuration
Submergence shield
For applications with flooding
possible
Certificates and approvals
CE (EMC certificate available on
request), CSA Class I Div. 2,
FM Class I, ATEX II 2G, SAA Ex s
Class I
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XRS-5
Selection and Ordering data
Order code
Selection and Ordering data
Order No.
C) 7ML1106Echomax XRS-5 transducer
With a beam angle of 10°, the XRS-5 provides relia7777 0 - 0 7
ble, continuous level monitoring of liquids and slurries in narrow lift stations/wet wells, flumes, weirs
and filter beds.
Measuring range: min. 0.3 m (1 ft), max. 8 m (26 ft)
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
(0.5 x 1.75")]: Measuring-point number/identification (max. 16 characters) specify in plain text
Process connection
1" NPT [(Taper), ANSI/ASME B1.20.1]
R 1" [(BSPT), EN 10226]
Accessories
Order No.
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, NPT with ¾" x 1" PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
FMS-200 universal box bracket, mounting kit
7ML1830-1BK
FMS-210 channel bracket, wall mount
7ML1830-1BL
FMS-220 extended channel bracket, wall mount
7ML1830-1BM
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
Facing
Standard (CSM rubber)
PTFE (flange versions)
Approvals
CE, FM Class I, ATEX II 2G, CSA Class I Div. 2,
SAA Class I
1
2
A
B
C
A
B
2
Y17
Mounting flange (flush mount)
None
A
FMS-310 channel bracket, floor mount
7ML1830-1BN
3" ASME, 150 lbs, flat faced
4" ASME, 150 lbs, flat faced
6" ASME, 150 lbs, flat faced
B
C
D
FMS-320 extended channel bracket, floor mount
7ML1830-1BP
7ML1830-1BQ
DN 80, PN 10/16, Type A, flat faced
DN 100, PN 10/16, Type A, flat faced
DN 150, PN 10/16, Type A, flat faced
J
K
L
FMS-350 bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
1" NPT locknut, plastic
7ML1830-1DS
JIS10K 3B style
JIS10K 4B style
JIS10K 6B style
Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1, or JIS B 2220 standard.
Q
R
S
1" BSPT locknut, plastic
7ML1830-1DR
Operating Instructions
Quick Start Manual, multi-language
C) 7ML1998-5QT81
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
C) Subject to export regulations AL: N, ECCN: EAR99
Siemens FI 01 · 2012
5/181
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XRS-5
■ Dimensional drawings
■ Schematics
Direct Connection
Submergence Shield
(optional)
white/shield
black/hot
black
white
155 (6.1)
127 (5.0)
25
(0.98)
Standard
89 (3.5)
shield
Coaxial Extension
Flange (optional)
124 (4.9)
127 (5.0)
junction box
5
extend cable using RG-62 A/U coax.
3 Terminal Direct*
ANSI, DIN, or JIS
Mounting:
Suspended Conduit
Bracket
rigid metal
conduit
black
white
flexible
conduit
steel
channel
shield
non-metallic
coupling
3 Terminal Extension*
non-metallic
coupling
black
white
transducer
shield
* For SITRANS LUC500, MultiRanger 100/200, HydroRanger 200
Flexible conduit transducer should not be
subjected to wind, vibration or jarring.
Plywood
XRS-5 ultrasonic transducer connections
Submersible
non-metallic
coupling
rigid metal
conduit
non-metallic
coupling
submergence
shield
Plywood mounting provides
excellent isolation
(must be rigid).
Transducer with submergence shield, used in
applications where flooding is possible.
XRS-5 ultrasonic transducer, dimensions, in mm (inch)
5/182
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
■ Overview
■ Benefits
•
•
•
•
•
•
Integral temperature compensation
Low ringing effect reduces blanking distance
Optional foam facing for dusty applications
Self-cleaning and low-maintenance
Chemically resistant
Hermetically sealed
■ Application
The transducers can be fully immersed, are resistant to steam
and corrosive chemicals, and can be installed without flanges.
The XPS series offers versions for various measuring ranges up
to 40 m (130 ft) and up to a max. temperature of 95 °C
(203 °F).
Echomax XPS/XCT transducers use ultrasonic technology to
measure level in a wide range of liquids and solids.
The XCT series can be used in applications at higher temperatures to measure level up to a distance of 12 m (40 ft) and at a
max. temperature of 95 °C (203 °F).
During operation, the Echomax transducers emit acoustic
pulses in a narrow beam. The level monitor measures the propagation time between pulse emission and its reflection (echo) to
calculate the distance.
Siemens FI 01 · 2012
5/183
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
■ Technical specifications
Input
XPS-10 (standard
and F models)
XPS-15 (standard
and F models)
XPS-30
XPS-40
XCT-8 (standard
and sanitary
models)
XCT-12
Measuring range
0.3 ... 10 m
(1 ... 33 ft)
Standard:
0.3 ... 15 m
(1 ... 50 ft)
Flanged:
0.45 ... 15 m
(1.5 ... 50 ft)
0.6 ... 30 m
(2 ... 100 ft)
0.9 ... 40 m
(3 ... 130 ft)
0.6 ... 8 m
(2 ... 26 ft)
0.6 ... 12 m
(2 ... 40 ft)
Frequency
44 kHz
44 kHz
30 kHz
22 kHz
44 kHz
44 kHz
Beam angle
12°
6°
6°
6°
12°
6°
Standard:
-40 ... +145 °C
(-40 ... +293 °F)
Sanitary:
-40 ... +125 °C
(-40 ... +260 °F)
-40 ... +145 °C
(-40 ... +293 °F)
Output
Environmental
5
Location
Indoors/outdoors
Ambient
temperature
Standard: -40 ... +95 °C (-40 ... +203 °F)
F: -20 ... +95 °C (-4 ... +203 °F)
Pollution degree
4
Pressure
8 bar g (120 psi g)
Flanged:
0.5 bar g
(7.25 psi g)
8 bar g (120 psi g)
Flanged: 0.5 bar g
(7.25 psi g)
0.5 bar g
(7.25 psi g)
Flanged: 0.5 bar g
(7.25 psi g)
0.5 bar g
(7.25 psi g)
Standard: 4 bar g (60 psi g):
-40 ... +138 °C (-40 ... +280 °F)
Standard: 8 bar g (120 psi g):
-40 ... +95 °C (-40 ... +203 °F)
Flanged: 0.5 bar g (7.25 psi g)
Sanitary: XCT-8: 0.5 bar g (7.25 psi g)
Weight
0.8 kg
(1.8 lbs)
1.3 kg (2.8 lbs)
Flanged: 2 kg
(4.4 lbs)
4.3 kg
(9.5 lbs)
8 kg
(18 lbs)
0.8 kg
(1.7 lbs)
Power supply
Operation of transducer only with approved Siemens Milltronics controllers
Material
Standard: PVDF
Flanged: PVDF with
CPVC flange
Option: PTFE face
with CPVC flange
Standard: PVDF
Flanged: PVDF with
CPVC flange
Option: PTFE face
with CPVC flange
Standard: PVDF
PVDF
Flanged: PVDF with
CPVC flange
Option: PTFE face
with CPVC flange
Standard: PVDF
Options: DERAKANE flange; PTFE face
with universal PVDF flange
Color
Standard: blue
F: gray
Standard: blue
F: gray
blue
white
Process
connection
Standard: 1" NPT or Standard: 1" NPT or 1.5" universal thread (NPT or BSPT)
1" BSPT
1" BSPT
F: 1" NPT
F: 1" NPT
1" NPT or R 1" (BSPT), EN 10226
Degree of
protection
IP66/68
IP66/68
Cable
2 wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket
Separation
Max. 365 m (1200 ft)
Certificates and
approvals
Standard:
CE1), CSA, FM,
ATEX II 2GD
F: FM Class I, Div 1,
Groups A, B, C and
D, Class II Div 1,
Groups E, F and G,
Class III
Design
1)
EMC certificate available on request.
5/184
Siemens FI 01 · 2012
IP66/68
IP66/68
Standard:
CE1), CSA, FM,
CE1), CSA, FM,
ATEX II 2G 1D
ATEX II 2GD
F: FM Class I, Div 1,
Groups A, B, C and
D, Class II Div 1,
Groups E, F and G,
Class III
blue
IP66/68
CE1), CSA, FM,
ATEX II 2G 1D
1.3 kg
(2.8 lbs)
IP66/68
2 wire twisted pair/braided and foil
shielded 0.5 mm² (20 AWG) silicone
jacket
Standard:
CE1), CSA, FM,
ATEX II 2GD
Sanitary: CE,
CTICK, CSAUS/C
CE1), CSA, FM,
ATEX II 2GD
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Order No.
C) 7ML1170Echomax XPS-10 ultrasonic transducer
High-frequency ultrasonic transducer designed for
7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max.10 m
Selection and Ordering data
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam
facing1)
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE
facing2)
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226] with foam facing1)
R 1" [(BSPT), EN 10226] with PTFE facing2)
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
0
1
Operating Instructions
Quick Start guide, multi-language
C) 7ML1998-5QM82
2
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
3
4
5
Order No.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on
sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Mounting flange
None
A
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
C
D
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
Universal box bracket, mounting kit
7ML1830-1BK
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
E
F
DN 80, PN 10/16, Type A, flat faced
DN 100, PN 10/16, Type A, flat faced
DN 150, PN 10/16, Type A, flat faced
G
J
L
JIS10K3B Style
JIS10K4B Style
JIS10K6B Style
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1, or JIS B 2220 standard.)
M
P
R
Approvals
ATEX II 2 GD, FM Class I Div. 2, SAA Class I
CSA Class I Div. 13)
3
4
C) Subject to export regulations AL: N, ECCN: EAR99.
1)
Not available with flanged versions
Available with flanged versions only
3) Valid with mounting thread and facing options 0 to 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
2)
Siemens FI 01 · 2012
5/185
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Order No.
C) 7ML1170Echomax XPS-10F ultrasonic transducer
High-frequency ultrasonic transducer designed for
7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max.10 m
Selection and Ordering data
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
5
1
Selection and Ordering data
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
D
50 m (164.04 ft)
100 m (328.08 ft)
E
F
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Y15
Order No.
Quick Start guide, multi-language
C) 7ML1998-1DU01
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Mounting flange, flush mount
None
A
Accessories
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
B
C
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
6" ASME, 150 lb, flat faced
8" ASME , 150 lb, flat faced
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2220 standard.)
D
E
Submergence shield kit
7ML1830-1BH
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Easy Aimer 304, with stainless steel coupling
7ML1830-1AU
Universal box bracket, mounting kit
7ML1830-1BK
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
Approvals
FM Class I Div. 1
C) Subject to export regulations AL: N, ECCN: EAR99.
1
C) Subject to export regulations AL: N, ECCN: EAR99.
5/186
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Selection and Ordering data
Order No.
C) 7ML1118Echomax XPS-15 ultrasonic transducer
High-frequency ultrasonic transducer designed for
777 7 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max. 15 m
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1] with foam
facing1)
1" NPT [(Taper), ANSI/ASME B1.20.1] with PTFE
facing2)
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226] with foam facing1)
R 1" [(BSPT), EN 10226] with PTFE facing2)
0
1
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Order No.
Operating Instructions
2
3
4
5
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Y15
Quick Start guide, multi-language
C) 7ML1998-5QM82
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BJ
7ML1830-1BK
Mounting flange
None
A
Universal box bracket, mounting kit
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10/16, Type A, flat faced
J
K
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5
or EN 1092-1, or JIS B 2220 standard.)
Approvals
ATEX II 2GD, FM Class I Div. 2, SAA Class I
CSA Class I Div. 13)
1)
Not available with flanged versions
2)
Available with flanged versions only
3)
Available with mounting options 0 to 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
N
P
3
4
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/187
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Order No.
C) 7ML1171Echomax XPS-15F ultrasonic transducer
High-frequency ultrasonic transducer designed for
7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.3 m, max. 15 m
Selection and Ordering data
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
C) 7ML1123Echomax XPS-30 ultrasonic transducer
High-frequency ultrasonic transducer designed for
777 7 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Measuring range: min. 0.6 m (1.97 ft), max. 30 m
(98.43 ft)
1
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
D
50 m (164.04 ft)
100 m (328.08 ft)
E
F
Mounting flange, flush mount
None
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2220 standard.)
5
Order No.
Selection and Ordering data
Mounting thread and facing
1½" universal thread
1½" universal thread, foam facing1)
1½" universal thread, PTFE facing2)
A
B
C
Approvals
FM Class I Div. 1
1
C) Subject to export regulations AL: N, ECCN: EAR99.
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
Order code
Y15
Order No.
Quick Start guide, multi-language
C) 7ML1998-1DU01
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BJ
Universal box bracket, mounting kit
7ML1830-1BK
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
Easy Aimer 2, with ¾" x 1" NPT PVC coupling
7ML1830-1AQ
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
C) Subject to export regulations AL: N, ECCN: EAR99.
5/188
Siemens FI 01 · 2012
0
1
2
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Mounting flange
None
A
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10/16, Type A, flat faced
J
K
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1, or JIS B 2220 standard.)
N
P
Approvals
ATEX II 2G 1D, FM Class I Div 2, SAA
1)
2)
Not available with flanged versions
Available with flanged versions only
C) Subject to export regulations AL: N, ECCN: EAR99.
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Selection and Ordering data
Order code
Selection and Ordering data
Y15
C) 7ML1127Echomax XPS-40 ultrasonic transducer
High-frequency ultrasonic transducer designed for
777 7 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
1½" universal thread compatible with 1½" NPT and
R 1½" [(BSPT), EN 10226]
Measuring range: min. 0.9 m (2.95 ft), max. 40 m
(131.23 ft)
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
Order No.
Quick Start guide, multi-language
C) 7ML1998-5QM82
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Order No.
Mounting thread and facing
1½" universal thread
1½" universal thread, foam facing
0
1
Cable length
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
B
C
E
50 m (164.04 ft)
100 m (328.08 ft)
F
K
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
1½" BSPT locknut, plastic
7ML1830-1DP
Easy Aimer 2, 1½" NPT galvanized coupling
7ML1830-1AN
Approvals
ATEX II 2G 1D, FM Class I Div 2, SAA
Easy Aimer 2, 1½" NPT with stainless steel coupling
7ML1830-1AT
C) Subject to export regulations AL: N, ECCN: EAR99
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
C) Subject to export regulations AL: N, ECCN: EAR99.
Mounting flange
None
A
5
5
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Order No.
Operating Instructions
Quick Start guide, multi-language
C) 7ML1998-
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
5QM82
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
1½" BSPT locknut, plastic
7ML1830-1DP
Easy Aimer 2, 1½" NPT galvanized coupling
7ML1830-1AN
Easy Aimer 2, 1½" NPT with stainless steel coupling
7ML1830-1AT
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
C) Subject to export regulations AL: N, ECCN: EAR99.
J) Subject to export regulations AL: 91999, ECCN: EAR99.
Siemens FI 01 · 2012
5/189
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Selection and Ordering data
Order No.
C) 7ML1132Echomax XCT-8 ultrasonic transducer
High-frequency ultrasonic transducer designed for
7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Ambient temperatures up to 145 °C (293 °F)
Measuring range: min. 0.6 m (2 ft), max. 8 m (26 ft)
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1],
PTFE facing1)
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226], PTFE facing1)
Cable length
1 m (3.28 ft)
5 m (16.40 ft)
10 m (32.81 ft)
30 m (98.43 ft)
50 m (164.04 ft)
100 m (328.08 ft)
5
2
XCT-8 with Sanitary Flange, multi-language
Note: This manual should be ordered as a separate
line item with Mounting Option V.
C) 7ML1998-5HX62
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
5QM82
3
A
B
C
E
F
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
K
Accessories
DN 80, PN 10/16, Type A, flat faced
DN 100, PN 10/16, Type A, flat faced
DN 150, PN 10/16, Type A, flat faced
G
J
L
M
P
R
3"
4" universal3)
6" universal4)
S
T
U
4" sanitary flange5)
V
2)
3)
4)
5)
C)
4
5
Siemens FI 01 · 2012
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
Submersible hood
7ML1830-1BH
Universal box bracket, mounting kit
7ML1830-1BK
Channel bracket, wall mount
7ML1830-1BL
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
Extended channel bracket, floor mount
7ML1830-1BP
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer, aluminum, with M20 adapter and
¾ ... 1" and 1½" BSPT couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
Sanitary, 4" mounting clamp
Sanitary, isolating gasket
7ML1830-1BR
J) 7ML1830-1KC
7
Available with flange versions S to V only
Universal fits 3" ASME, DN 80, JIS 10K3B style
Universal fits 4" ASME, DN 100, JIS 10K4B style
Universal fits 6" ASME, DN 150, JIS 10K6B style
Available with Mounting thread and facing options 1 and 3, and approval
option 7 only
Subject to export regulations AL: N, ECCN: EAR99.
5/190
Order No.
C) 7ML1998-
C
D
E
1)
Y15
Quick start manual, multi-language
3" ASME, 150 lb, flat faced
4" ASME, 150 lb, flat faced
6" ASME, 150 lb, flat faced
Approvals
ATEX II 2GD, FM Class I, Div. 2, SAA
CSA Class I Div. 1, available with mounting thread
and facing option 0
CE, C-TICK, CSAUS/C
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Operating Instructions
A
universal2)
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
0
1
Mounting flange
None
JIS10K 3B
JIS10K 4B
JIS10K 6B
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 or JIS B 2220 standard.)
Selection and Ordering data
C) Subject to export regulations AL: N, ECCN: EAR99.
J) Subject to export regulations AL: 91999, ECCN: EAR99.
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
■ Dimensional drawings
■ Schematics
Standard
J
Direct Connection
black
B
white
shield
Coaxial Connection
Radiating face
A
white
shield
Submergence shield
F
B
Bonded flange
3 Terminal Direct*
black
shield
C
Sanitary
5
white
E
3 Terminal Extension*
H
black
white
shield
G
* For SITRANS LUC500, MultiRanger 100/200, HydroRanger 200
Radiating PTFE face
XPS and XCT ultrasonic transducer, dimensions, in mm (inch)
Version
Dimension
XPS-10
XPS-15
XPS-30
XPS-40
A
88 mm
(3.464")
121 mm
(4.764")
175 mm
(6.890“)
206 mm
(8.110")
B
122 mm
(4.803")
132 mm
(5.197")
198 mm
(7.795")
229 mm
(9.016")
C
According to ASME, DIN and JIS
n/a
E
124 mm
(4.882")
158 mm
(6.220")
n/a
n/a
F
152 mm
(5.984")
198 mm
(7.795")
n/a
n/a
J
28 mm (1.1") 28 mm (1.1") 28 mm (1.1") 28 mm (1.1")
Mounting
Make particularly sure that the radiating face of the transducer is protected from damage.
Mount the transducer so that it is above the maximum material level by at least
the blanking value. On liquid applications, the transducer must be mounted so that
the axis of transmission is perpendicular to the liquid surface. On solids alications,
a Milltronics Easy Aimer should be used to facilitate aiming the transducer. Consider
the optional temperature sensor when mounting the transducer.
Interconnection
Do not route cable openly or near high voltage or current runs, contactors and
SCR control drives. For optimum isolation against electrical noise, run cable
separately in a grounded metal conduit. Seal all thread connections to prevent
ingress of moisture.
XPS and XCT ultrasonic transducer connections
Version
Dimension
XCT-8
XCT-12
A
88 mm (3.464")
121 mm (4.764")
B
122 mm (4.803")
132 mm (5.197")
C
According to ASME, DIN and JIS
E
n/a
n/a
F
n/a
n/a
G
Sanitary version:
119 mm (4.68")
n/a
H
Sanitary version:
122 mm (4.8")
n/a
J
28 mm (1.1")
28 mm (1.1")
Siemens FI 01 · 2012
5/191
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XPS and XCT
Selection and Ordering data
Order No.
C) 7ML1136Echomax XCT-12 ultrasonic transducer
High-frequency ultrasonic transducer designed for
7777 0
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Ambient temperatures up to 145 °C (293 °F)
Measuring range: min. 0.6 m (2 ft), max.12 m (40 ft)
Mounting thread and facing
1" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1], PTFE facing,
available for flange options U only1)
R 1" [(BSPT), EN 10226]
R 1" [(BSPT), EN 10226], PTFE facing,
available for flange options U only1)
5
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Order No.
0
1
Operating Instructions
Quick start manual, multi-language
C) 7ML1998-
2
3
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
C) 7ML1998-5HV61
5QM82
Cable length
1 m (3.28 ft)
5 m (16.40 ft)
10 m (32.81 ft)
A
B
C
30 m (98.43 ft)
50 m (164.04 ft)
100 m (328.08 ft)
E
F
K
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
Submergence shield kit
7ML1830-1BJ
Universal box bracket, mounting kit
7ML1830-1BK
Mounting flange
None
A
Channel bracket, wall mount
7ML1830-1BL
6" ASME, 150 lb, flat faced
8" ASME, 150 lb, flat faced
D
E
Extended channel bracket, wall mount
7ML1830-1BM
Channel bracket, floor mount
7ML1830-1BN
DN 150, PN 10/16, Type A, flat faced
DN 200, PN 10/16, Type A, flat faced
J
K
Extended channel bracket, floor mount
7ML1830-1BP
JIS10K 6B
JIS10K 8B
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or
EN 1092-1 or JIS B 2220 standard.)
N
P
Bridge channel bracket, floor mount
(see Mounting Brackets on page 5/198 for more
information)
7ML1830-1BQ
1" NPT locknut, plastic
7ML1830-1DS
1" BSPT locknut, plastic
7ML1830-1DR
6" universal for 6" ASME, DN 150 or JIS 10K6B style
U
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer 2, aluminum with M20 adapter and
1" and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
Approvals
ATEX II 2GD, FM Class I, Div. 2, SAA
CSA Class I, Div. 1, available with mounting thread
and facing option 0 only
3
4
1)
Available with universal flanges only
C) Subject to export regulations AL: N, ECCN: EAR99.
5/192
Siemens FI 01 · 2012
C) Subject to export regulations AL: N, ECCN: EAR99.
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XLT
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic transducer
Input
Measuring range
• XLT-30
0.9 ... 30 m (3.0 ... 100 ft)
• XLT-60
1.8 ... 60 m (6.0 ... 200 ft)
Output
Frequency
• XLT-30
22 kHz
• XLT-60
• Beam angle1)
13 kHz
5°
Accuracy
Temperature error
Echomax XLT transducers use ultrasonic technology to measure
level in a wide range of bulk solids.
■ Benefits
•
•
•
•
•
Sealed aluminum face
Integral temperature sensor
Self-cleaning and low maintenance
Connect using only two wires
Easy to install
■ Application
XLT transducers operate with Siemens SITRANS LU transceivers
in measuring ranges from 0.9 to 60 m (1.8 ... 200 ft) and temperatures up to 150 °C (300 °F). A beam angle of just 5° provides
accurate readings in deep, narrow tanks.
With increased signal sensitivity, the XLT transducers from
Siemens can operate in difficult applications such as limestone,
cement clinker and hot stone. All models have a sealed aluminum face to withstand very harsh environments.
During operation, Echomax transducers emit acoustic pulses in
a narrow beam. The level transceiver measures the propagation
time between pulse emission and reception of the echo to calculate the distance from the transducer to the material. Temperature variations are automatically compensated by the integral
temperature sensor.
• Key Applications: bulk solids including limestone, cement
clinker, hot stone and coal bunkers
Compensated by transducers
internal temperature sensor
Rated operating conditions
Ambient conditions
• Ambient temperature
- XLT-30 and XLT-60
-40 ... +150 °C (-40 ... +300 °F)
Design
Weight
• XLT-30
4.3 kg (9.5 lbs)
• XLT-60
6.6 kg (14.5 lbs)
Material (enclosure)
Aluminium, 304 stainless steel,
polyester and silicone
Degree of protection
IP68
Color
• XLT-30 and XLT-60
Red
Mounting
1" NPT [(Taper), ANSI/ASME
B1.20.1]
Cable connection
2-core shielded/twisted, 0.5 mm²
(20 AWG), silicone sheath
Cable (max. length)
365 m (1200 ft) with RG 62 AU
coaxial cable
Certificates and approvals
CE (EMC certificate available
on request), CSAUS/C, FM,
ATEX II 2G 1D T5
1)
Definition of beam width: twice the angle at which the off-axis transmission
is 3 dB less than the acoustic pressure level of the transmission axis
(as measured equidistant from the sensor face).
Siemens FI 01 · 2012
5/193
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XLT
Order No.
Selection and Ordering data
XLT-30
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Acrylic coated, stainless steel tag [13 x 45 mm
Stainless steel tag [69 x 50 mm (2.71 x 1.97")]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Order No.
Operating Instructions
C) 7ML1141-
Quick start manual, multi-language
C) 7ML1998-5QS81
77E70
C) 7ML1998-5HV61
Facing
XLT-30
XLT-60
XLT-30, nylon
Applications Guidelines, multi-language
Note: The Applications Guidelines should be
ordered as a separate line item on the order.
0
1
2
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
XLT-60, nylon
3
Accessories
XLT-60
5
Order code
Selection and Ordering data
Echomax XLT-30, XLT-60, ultrasonic transducer
High-frequency ultrasonic transducer designed for
a wide variety of liquid and solid applications, for
use with approved controllers. Includes integral
temperature sensor.
Measuring range: min. 0.9 m, max. 30 m
Process connection:
1" NPT [(Taper), ANSI/ASME B1.20.1]
C) 7ML1145-
Cable length
1 m (3.28 ft)
5 m (16.40 ft)
10 m (32.81 ft)
A
B
C
20 m (65.62 ft)
30 m (98.43 ft)
50 m (164.04 ft)
D
E
F
70 m (229.66 ft)
80 m (262.47 ft)
90 m (295.28 ft)
G
H
J
100 m (328.08 ft)
K
Approvals
ATEX II 2G 1D, CSA Class I Div. 1, FM Class I
Div. 2, CE
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77"), one text line for fastening on sensors
7ML1930-1BJ
Easy Aimer 2, 1" NPT galvanized
7ML1830-1AP
Easy Aimer 304 with stainless steel coupling
7ML1830-1AU
Easy Aimer 2, aluminum with M20 adapter and 1"
and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
C) Subject to export regulations AL: N, ECCN: EAR99.
3
C) Subject to export regulations AL: N, ECCN: EAR99.
■ Schematics
Direct Connection
black
white
2 Wire Extension
Siemens Milltronics
Transceiver
black / Hot
white / Shield
black
white
Coaxial Extension
Junction box
Drain / Shield
Note 1
Notes
1. Extend cable using 18 AWG shield / twisted pair up to 100 m (333 ft).
2. Extend cable using RG-62 A/U coax for optimum signal to noise ratio up to 365 m (1200 ft).
XLT ultrasonic transducer connections
5/194
Siemens FI 01 · 2012
black
Junction box
white
Note 2
© Siemens AG 2011
Level Measurement
Continuous level measurement — Ultrasonic transducers
Echomax XLT
■ Dimensional drawings
Earth connection
screw clamp
(1 place)
1” NPT
Safety connection
9 mm (3/8”) diam. hole
(2 places)
Easy Aimer
(typical model)
h
Safety chain
Earth connection
d
Mounting - Liquid Applications
Flexible Conduit
Flexible conduit
Plate or bracket
5
Coupling
Safety chain
To nearest earth
Transducer
Ripple welded
to blind flange
Blind Flange
To nearest earth
Coupling
Safety chain
Earth connection
XLT ultrasonic transducer, dimensions, in mm (inch)
XLT-30
XLT-60
d
264 mm (10.4")
335 mm (13.2")
h
249 mm (9.8")
324 mm (12.75")
Siemens FI 01 · 2012
5/195
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
EA aiming devices
■ Application
■ Application
EA 304 aiming device
EA 2 aiming device
The Easy Aimer 304 flange is a stainless steel aiming device for
alignment of Siemens ultrasonic transducers used for level measurement of bulk solids.
The Easy Aimer 2 flange is a cast aluminum aiming device for
alignment of Siemens ultrasonic transducers.
The sensor must be mounted aimed towards the low level draw
point in the silo. The sensor can be rotated through 360° and angled at 0 to 27° off vertical. It must be mounted using an access
plate with welded studs or a flange in order to isolate the mounting holes from the pressurized environment. When installed
properly, the EA 304 aiming device is capable of withstanding
pressures up to 0.5 bar (Europe) or 15 psi (North America). It
can even be used in corrosive and aggressive environments.
■ Dimensional drawings
The flange has graduated adjustments and an adjustable
insertion length. When used for applications with bulk solids,
the sensor is mounted so that it is aimed towards the lower level
draw point in the silo. The sensor can be rotated through 360°
and angled at 0 to 20° off vertical. It must be mounted using an
access plate with welded studs or a flange in order to isolate the
mounting holes from the pressurized environment. When installed properly, the EA 2 aiming device is capable of withstanding pressures up to 0.5 bar (Europe) or 15 psi (North America).
It can even be used in corrosive and aggressive environments.
■ Dimensional drawings
10 (0.38)
Locknut
Clamping plate
(upper socket)
Conduit gland
Mounting block
(lower socket)
135 (5.3)
nominal
Customer gasket
(as required)
Angle block
Sighting block
76 (3)
nominal
16
(0.63)
Mounting block
Customer gasket
(as required)
Customer
mounting plate
(as required)
Ø127 (5)
typical
Coupling/adapter
Customer mounting
plate (as required)
127 (5)
Ø typical
Siemens
Milltronics
transducer
(typical)
Coupling/Adapter
Siemens Milltronics
Transducer (typical)
max 20°
Mounting hole - 3 places
to suit M8 or ⅜",
120° apart on 157 mm
(6.2") bolt center diameter
Mounting hole 3 places 11 (7/16)
on 157 (6.2) bolt
center diameter
Angle block binding
screw and clamp
LL
TR
max. 27°
MI
ON I
CS
5
170 (6.7)
¾" NPT or BSP conduit x
300 (12) long
1" NPT or BSP
Sighting block binding
screw and clamp
Ground screw
Clamping screw
(3 places)
A
E
SY
A IM
ER
II
Ground screw
178 (7)
EA 304 aiming device, dimensions in mm (inch)
5/196
Siemens FI 01 · 2012
178
(7.0)
EA 2 aiming device, dimensions in mm (inch)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
EA aiming devices
Selection and Ordering data
Order No.
Easy aimer
Used on solids applications to aim transducers for
optimal performance. Available in a 304 stainless
steel model, or a cast aluminum model.
Easy Aimer 2, aluminum with M20 adapter and 1"
and 1½" BSPT aluminum couplings
7ML1830-1AX
Easy Aimer 304, with M20 adapter and 1" and
1½" BSPT 304 SS couplings
7ML1830-1GN
Easy Aimer 2, aluminum, BSPT conduit
Easy Aimer 2, aluminum, NPT with 1½" galvanized
coupling1)
7ML1830-1AL
Easy Aimer 2, aluminum, NPT with 1" galvanized
coupling
Easy Aimer 2, aluminum, NPT with ¾" x 1"
PVC coupling
7ML1830-1AP
Easy Aimer 304, BSPT conduit
Easy Aimer 304, NPT with 1½" coupling1)
7ML1830-1AS
Easy Aimer 304, NPT with 1" coupling
7ML1830-1AU
Operating Instructions
Easy Aimer 2 and 304 Operating Instructions,
Multi-language
Note: The Operating Instructions should be
ordered as a separate line item on the order.
7ML1830-1AN
7ML1830-1AQ
7ML1830-1AT
7ML1998-5HG62
5
This device is shipped with the Siemens Milltronics
manual CD containing the complete Quick Start and
Operating Instructions library.
1)
For use with XPS-30 or XPS-40 transducers only
Siemens FI 01 · 2012
5/197
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
FMS mounting brackets
■ Application
■ Integration
Siemens mounting brackets permit simple, fast installation of ultrasonic transducers. These rugged, high quality mounting
brackets are constructed of 304 (1.4301) stainless steel and are
suitable for use indoors and outdoors. They adjust to fit almost
any application, saving you the time and expense of building
custom brackets. Each kit includes all mounting parts.
FMS-200
Universal Box bracket
FMS-200
universal box bracket system
Mounting of units with 1" or 2" threaded connection.
Distance from sensor to wall or beam: 20 to 31 cm (8 to 12").
FMS-210
Channel Bracket,
Wall Mount
The unique box design also acts as a sun shield for transducers
with 1" threaded connections.
FMS-210
wall mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to wall or beam: 12 to 48 cm (5 to 19").
5
FMS-220
Extended Channel Bracket,
Wall Mount
FMS-220
extended wall mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to wall or beam: 32 to 98 cm
(13 to 39").
FMS-310
floor mounting set
Mounting of transducers with 1" threaded connection.
Distance from transducer to floor: 20 to 48 cm (8 to 19").
Distance from mounting support: 5 to 57 cm (2 to 22").
FMS-320
extended floor mounting set
Mounting of transducers with 1" threaded connection.
FMS-310
Channel Bracket,
Floor Mount
Distance from transducer to floor: 20 to 48 cm (8 to 19").
Distance from mounting support: 41 to 108 cm (16 to 43").
FMS-350
floor mounting set, bridge
Mounting of transducers with 1" threaded connection.
Distance from transducer to floor: 20 to 48 cm (8 to 19"), anywhere along the complete width of the bridge [166 cm (65")].
This kit is particularly suitable for measurements on open channels (OCM) by providing a very stable mount for the transducer
above a flume or weir.
FMS-320
Extended Channel Bracket,
Floor Mount
FMS-350
Bridge Channel Bracket,
Floor Mount
FMS mounting brackets
5/198
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
FMS mounting brackets
Selection and Ordering data
Order No.
Mounting brackets for XPS-10/XCT-8 sensors
FMS-200 universal box bracket set
7ML1830-1BK
FMS-210 wall mounting set
7ML1830-1BL
FMS-220 extended wall mounting set
7ML1830-1BM
FMS-310 floor mounting set
7ML1830-1BN
FMS-320 extended floor mounting set
7ML1830-1BP
FMS-350 floor mounting set, bridge
7ML1830-1BQ
Additional Operating Instructions
FMS-200
C) 7ML1998-5BK61
FMS-210
C) 7ML1998-5BL61
FMS-220
C) 7ML1998-5BM61
FMS-310
C) 7ML1998-5BN61
FMS-320
C) 7ML1998-5BP61
C) 7ML1998-5BQ61
FMS-350
Note: The Operating Instructions should be ordered as a separate line item on the order.
C) Subject to export regulations AL: N, ECCN: EAR99.
5
Siemens FI 01 · 2012
5/199
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
TS-3 temperature sensor
■ Overview
■ Design
Clearance
Conduit (supplied by others)
Coupling (supplied by others)
TS-3
Plate or wall
Locknut (supplied by others)
The TS-3 temperature sensor provides an input signal for
temperature compensation of specific Siemens ultrasonic level
controllers.
5
Note: Clearance Hole/
Locknut Installation
method is not suitable
for pressure applications.
■ Benefits
• Chemically resistant ETFE enclosure
• Fast response time
• Approved for use in potentially explosive atmospheres
Tapped
■ Application
Temperature compensation is essential in applications where
temperature variations of the sound medium are expected.
By installing the temperature sensor close to the sound path of
the associated ultrasonic transducer, a signal representative of
the sound medium’s ambient temperature is obtained. The temperature sensor should not be mounted in direct sunlight.
The TS-3 is used in conjunction with ultrasonic transducers that
do not have an integral temperature sensor. It is also recommended in cases where the integral temperature sensor of the
transducer cannot be used.
Flange or wall
The following conditions are typical for use of the TS-3 sensor:
where a fast reaction to temperature variations is required, where
a flanged ultrasonic transducer is used, or where high temperatures are encountered.
The TS-3 is not compatible with devices using the TS-2 or LTS-1
temperature sensors. Refer to the associated controller manual
for more details.
• Key Applications: For use in applications where temperature
sensor measurement from transducer does not accurately
represent vessel temperature. Used for applications requiring
quick temperature response (open channel monitoring).
5/200
Siemens FI 01 · 2012
TS-3 temperature sensor
© Siemens AG 2011
Level Measurement
Continuous level measurement — Accessories for ultrasonic
TS-3 temperature sensor
■ Technical specifications
Mode of operation
Measuring principle
Temperature sensor
Input
Measuring range
-40 ... +150 °C (-40 ... + 302 °F)
Output
Cable length
Response time
1 m (3.28 ft)
1
5 m (16.40 ft)
2
90 s
10 m (32.81 ft)
3
150 s
30 m (98.43 ft)
4
50 m (164.04 ft)
5
70 m (229.66 ft)
6
90 m (295.28 ft)
7
• Forced circulation (temperature
variation: 63 %)
55 s
• Flange, forced circulation
• Natural convection
Rated operating conditions
• Installation instructions
Mounted indoors/outdoors, but
not exposed to direct sunlight
• Pressure
Max. 4 bar (60 psi/400 kPa)
Process connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226]
Design
Material (enclosure)
ETFE1)
Cable connection
2-core, 0.5 mm² (20 AWG),
shielded, silicone sheath
Process connection
¾" NPT [(Taper),
ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226], totally
encapsulated
Certificates and approvals
1)
Order No.
C) 7ML1813TS-3 temperature sensor
TS-3 provides an input signal for temperature
77 B 7
compensation of specific Siemens ultrasonic level
controllers.
Compensation is essential in applications where
variation in temperature of the sound medium is
expected.
Selection and Ordering data
SAA, FM, CSA, ATEX
ETFE is a fluoropolymer inert to most chemicals. For exposure to
specific environments, check the chemical compatibility charts before
installing the TS-3 in your application.
■ Dimensional drawings
A
B
Approvals
CSA, FM
ATEX, SAA
5
3
4
Operating Instructions
English
C) 7ML1998-5EM01
German
C) 7ML1998-1EM31
Note: The Operating Instructions should be
ordered as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing ATEX Quick Starts and
Operating Instructions.
Optional equipment
¾" NPT locknut, aluminum
Siemens Milltronics instrument
B W
L H
K T
C) 7ML1930-1BE
Tag, stainless steel with hole, 12 x 45 mm
(0.47 x 1.77") for fastening on sensors
7ML1930-1BJ
C) Subject to export regulations AL: N, ECCN: EAR99.
Cable
Connect direct or via customer junction box
15 mm
(0.6")
20 mm
(0.8")
15 mm
(0.6")
136 mm
(5.4")
76 mm
(3.0")
¾" NPT or
R ¾" BSPT
(2 places)
Hex hub
27 mm (1 1/16")
TS-3 temperature sensor, dimensions in mm (inch)
Siemens FI 01 · 2012
5/201
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
Radar transmitters
■ Overview
■ Mode of operation
Radar measurement technology is non-contacting and low
maintenance. Because microwaves require no carrier medium,
they are virtually unaffected by the process atmosphere (vapour,
pressure, dust, or temperature extremes). Siemens offers a
variety of models to meet the specific needs of your application.
Principle of Operation
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage vessels
with nominal pressure and temperature, to a range of 20 m (66 ft).
Unlike ultrasonic measurement, radar technology does not
require a carrier medium and travels at the speed of light
(300 000 000 m/s). Most industrial radar devices operate from
6 to 26 GHz.
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, corrosive or aggresive materials, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media.
5
SITRANS LR260 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of solids in silos to a range of 30 m
(98.4 ft). Ideal for applications with extreme dust and high temperatures to 200 °C (392 °F).
SITRANS LR400 is a 4-wire, 24 GHz FMCW radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and high pressure, to
a range of 50 m (164 ft). It is ideal for low dielectric media.
SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmitter
with extremely high signal to noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It
is ideal for measurement in extreme dust.
Radar measurement technology measures the time of flight
from the transmitted signal to the return signal. From this time,
distance measurement and level are determined.
Siemens offers pulse radar transmitters (SITRANS Probe LR,
SITRANS LR200, SITRANS LR250, SITRANS LR260) and
FMCW (Frequency Modulated Continuous Wave) radar transmitters (SITRANS LR400, SITRANS LR560).
Pulse radar emits a microwave pulse from the antenna at a fixed
repetition rate that reflects off the interface between the two
materials with different dielectric constants (the atmosphere and
the material being monitored). The echo is detected by a receiver and the transmit time is used to calculate level.
Reflected echoes are digitally converted to an echo profile.
The profile is analyzed to determine the distance from the
material surface to the reference point on the instrument.
FMCW (Frequency Modulated Continuous Wave)
radar devices send microwaves to the surface of the material.
The wave frequency is modulated continuously. At the same
time, the receiver is also receiving continuously and the
difference in frequency between the transmitter and the receiver
is directly proportional to the distance to the material.
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m (329 ft).
Level (db)
Auto False-Echo Suppression
SITRANS LR instruments offer the unique advantage of patented
Process Intelligence signal processing technology. This indepth
knowledge and experience is built into the software’s advanced
algorithms to provide intelligent processing of echo profiles.
The result is repeatable, fast and reliable measurement.
Echo from
agitator
A special feature of SITRANS radar devices is Auto False-Echo
Suppression, an echo processing technique that automatically
detects and suppresses false echoes from vessel obstructions.
You can implement this feature using two parameters on the
local interface or SIMATIC PDM communicating over HART or
PROFIBUS PA.
Surface echo
Local display interface – graphically displays echo
profiles and diagnostic information
(available with LR200, LR250, LR260)
Quick to configure – Quick Start Wizard via SIMATIC
PDM guides you during setup
(available with LR200, LR250, LR260, LR460, LR560)
Distance
Radar operation in a reactor vessel
5/202
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
Radar transmitters
■ Technical specifications
Radar Selection Guide
Criteria
SITRANS
Probe LR
SITRANS LR200 SITRANS LR250 SITRANS LR260 SITRANS LR400 SITRANS LR460 SITRANS LR560
Typical
industries
Chemicals
Chemicals, petro- Chemicals,
chemicals
petrochemicals
Typical
applications
Liquids, storage
vessels
Liquids, storage
and process vessels with agitators, build up,
and high temperatures
Liquids, storage Cement, plastics,
and process ves- grain, flour, coal
sels with agitators, vaporous
liquids, high temperatures, low
dielectric media
Liquids storage Cement, flyash, Cement, flyash,
vessels, liquid
grain, coal, flour, grain, coal, flour,
petroleum gas
plastics
plastics
(LPG), and other
low dielectric
media
Range
0.3 ... 20 m
(1 ... 65 ft)
0.4 ... 20 m
(1.3 ... 65 ft)
50 mm (2 inch)
30 m (98.4 ft)
from end of horn
to 20 m (65 ft),
horn dependent
0.35 ... 50 m
(1.14 ... 164 ft)
100 m (328 ft)
40 m (131 ft)
100 m (328 ft)
Frequency
5.8 GHz
(North America
6.3 GHz)
5.8 GHz
(North America
6.3 GHz)
K-band
(25.0 GHz)
24 ... 25 GHz
FMCW
24 ... 25 GHz
FMCW
78 ... 79 GHz
Performance
accuracy
0.1% of range or 0.1% of range or 5 mm (0.02 inch) 25 mm (1 inch)
10 mm (0.4 inch) 10 mm (0.4 inch)
from minimum
detectable distance to 300 mm
(11.8 inch)
Remainder of
range = 10 mm
(0.39 inch) or
0.1% of span
(whichever is
greater)
≤ 5 mm (0.2 inch) 0.25 %
from 2 ... 10 m
(6.6 ... 32.8 ft)
≤ 15 mm
(0.6 inch) from 10
... 50 m (32.8 ...
164 ft)
0.25%
Temperature
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +80 °C
(-40 ... +176 °F
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +200 °C
(-40 ... +392 °F),
dependent on
antenna type
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +200 °C
(-40 ... +392 °F)
dependent on
antenna type
Ambient:
-40 ... +80 °C
(-40 ... +176 °F)
Process:
-40 ... +200 °C
(-40 ... +392 °F)
dependent on
antenna type
Ambient:
-40 ... +65 °C
(-40 ... +149 °F)
Process:
-40 ... +250 °C
(-40 ... +482 °F),
dependent on
antenna type
Ambient:
65 °C (149 °F)
Ambient:
-40 ... +80 °C
(-40 ... +176°F)
Process:
-40 ... +100 °C
(-40 ... 212 °F)
optional: 200 °C
(392 °F)
Output/
• 4 ... 20 mA/
communications/
HART
remote
• SIMATIC PDM
configuration
and diagnostics
• 4 ... 20 mA/
HART
• PROFIBUS PA
• SIMATIC PDM
• AMS
• SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
• 4 ... 20 mA/
HART
• PROFIBUS PA
• FOUNDATION
Fieldbus
• SIMATIC PDM
• AMS
• SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
• 4 ... 20 mA/
HART
• PROFIBUS PA
• SIMATIC PDM
• 4 ... 20 mA/
HART
• PROFIBUS PA
• SIMATIC PDM
• 4 ... 20 mA/
HART
• PROFIBUS PA
• SIMATIC PDM
Power
• 24 V DC
nominal
• Loop powered
• 24 V DC
nominal
• Loop powered
• 24 V DC
nominal
• Loop powered
• 24 V DC
nominal
• Loop powered
• 120 ... 230 V
• 100 ... 230 V
• 24 V DC
AC, ±15%,
AC, ±15%,
nominal
50/60 Hz
50/60 Hz, 6 W • Loop powered
• 24 V DC,
• 24 V DC,
+25/-20%, 6 W
+25/-20%, 6 W
(optional )
Approvals
CE, C-TICK, KC,
Lloyds Register of
Shipping, ABS,
FCC, Industry
Canada, R&TTE
ATEX,
CSA, FM,
INMETRO, GOST,
IECEx, ANZEx,
TIIS
CE, C-TICK,
KC, Lloyds Register of Shipping,
ABS, FCC,
Industry Canada,
R&TTE
ATEX, CSA, FM,
INMETRO, GOST,
IECEx, ANZEx,
TIIS, NEPSI
CE, C-TICK, KC,
Lloyds Register of
Shipping, ABS,
BV, FCC, Industry
Canada, R&TTE
ATEX, CSA, FM,
INMETRO, GOST,
IECEx, TIIS,
NEPSI
Functional safety
SIL-2
CE, C-TICK, KC,
FCC, Industry
Canada, R&TTE
ATEX, CSA, FM,
INMETRO, GOST,
IECEx
CE, C-TICK, KC,
Lloyds Register of
Shipping, ABS,
FCC, Industry
Canada, R&TTE
ATEX, CSA, FM,
GOST
Cement, power Chemicals, petrogeneration, food chemicals
processing, mineral processing,
mining
K-band
(25.0 GHz)
Cement, power
generation, food
processing, mineral processing,
mining
Process:
200 °C
(392 °F)
CE, C-TICK, KC,
FCC, Industry
Canada, R&TTE
ATEX, CSA, FM,
INMETRO, IECEx,
GOST
Cement, power
generation, food
processing, mineral processing,
mining
5
• 4 ... 20 mA/
HART
• PROFIBUS PA
• FOUNDATION
Fieldbus
• SIMATIC PDM
• AMS
• SITRANS
DTM/FDT for
PACTware,
Fieldcare,
etc.
CE, C-TICK,
KC, FCC,
Industry
Canada, R&TTE
ATEX, CSA, FM,
INMETRO, IECEx,
NEPSI, GOST
Siemens FI 01 · 2012
5/203
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
Radar transmitters
Radar Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Address:
Notes on the Application:
City:
Zip/Postal Code:
)
(
)
Fax:
E-mail:
Vessel Information
SITRANS
5
Country:
Phone: (
Sketch attached
(supply sketch where possible)
LR 400
Storage
Solids
Process
Storage
Liquids
Reactor
Area safety classification: (specify code required)
m/ft Diameter:
Height:
Top:
Atmosphere:
m/ft
Filling method:
Pressure:
(indicate all that apply)
Flat
Foam
Steam
Normal:
Parabolic
Dust
Deposit (build-up)
Maximum (relief):
Conical
Vapor
Mounting connection
(specify type)
Critical Information
Distance to sidewall:
cm/in
Mounting connection maximum temperature:
°C/°F
Max. temperature at electronics:
°C/°F
Stilling well or Still Pipe mounting:
Yes
No
Nozzle Length:
cm/in
Nozzle Diameter:
cm/in
Stilling well diameter:
cm/in
Material
Liquid
Material being measured:
Material temperature: Norm:
Material surface:
Flat
Installation
Power available:
°C/°F Max:
Turbulent
Agitated
Solid
°C/°F
Vortex
Dielectric constant:
Liquified gas
er < 3
er > 3
Communications:
HART ® /4 to 20 mA
PROFIBUS PA
FOUNDATION Fieldbus
None
Products recommended:
© Siemens Milltronics Process Instruments Inc.
5/204
Siemens FI 01 · 2012
www.siemens.com/processautomation
Form# 2-763R7
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS Probe LR
■ Overview
■ Configuration
Installation
min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.
beam
angle 28°
Mounting unit on vessel
5
SITRANS Probe LR is a 2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
vessels with nominal pressure and temperature, to a range of
20 m (66 ft).
• Uni-Construction polypropylene rod antenna standard
• Easy installation and simple startup
• Programming using infrared Intrinsically Safe handheld
programmer, SIMATIC PDM or HART handheld communicator
• Communication using HART
• Patented Process Intelligence signal processing
• Extremely high signal-to-noise ratio
• Auto False-Echo Suppression of false echoes
■ Application
The Probe LR is ideal for applications with chemical vapours,
temperature gradients, vacuum or pressure, such as tank farms,
chemical storage, digesters and long-range applications.
SITRANS Probe LR has a range of 0.3 to 20 m (1 to 65 ft).
Probe LR is designed for safe and simple programming using
the Intrinsically Safe handheld programmer without having to
open the instrument’s lid. It has a standard Uni-Construction
polypropylene rod antenna that offers excellent chemical
resistance and is hermetically sealed. The Uni-Construction
antenna includes an internal, integrated shield that eliminates
vessel nozzle interference.
Conical
Mounting on a manhole cover
Flat
Parabolic
Mounting on a nozzle
min.
10 (0.4)
■ Benefits
min. 100 (4)
SITRANS Probe LR
shield length 100 (4) or
250 (10) standard
lengths
SITRANS Probe LR installation, dimensions in mm (inch)
SITRANS Probe LR incorporates Process Intelligence signal processing. The Probe LR also has a high signal-to-noise ratio leading to improved reliability.
Start-up is easy with as few as two parameters for basic operation. Programming is simple using SIMATIC PDM, HART handheld communicator or the Intrinsically Safe handheld programmer.
• Key Applications: tank farms, chemical storage,
wastewater wet well
Siemens FI 01 · 2012
5/205
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS Probe LR
■ Technical specifications
Mode of operation
Power supply
Pulse radar level measurement
Frequency
5.8 GHz (North America 6.3 GHz)
Certificates and approvals
Measuring range
0.3 ... 20 m (1.0 ... 65 ft)
General
CSAUS/C, CE, FM, C-TICK
Marine
• Lloyd's Register of Shipping
• ABS Type Approval
FCC, Industry Canada and
European (R&TTE), C-TICK
Output
Analog output
4 ... 20 mA
Accuracy
± 0.02 mA
Radio
Span
Proportional or inversely
proportional
Hazardous
Communications
HART
• Europe
ATEX II 1G EEx ia IIC T4
• USA
Intrinsically Safe barrier required
FM Class I, Div.1, Groups
A,B,C,D; Class II, Div. 1, Groups
E,F, G; Class III
• Canada
Intrinsically Safe barrier required
CSA Class I, Div.1, Groups
A,B,C,D; Class II, Div. 1, Group G;
Class III
• Brazil - INMETRO
BR-Ex ia IIC T4
Performance
(reference conditions)
5
• Nominal 24 V DC with
max. 550 Ω, maximum 30 V DC
• 4 ... 20 mA
Measuring principle
Accuracy
± the greater of 0.1% of range or
10 mm (0.4 inch)
Influence of ambient temperature
0.003%/K
Repeatability
± 5 mm (2 inch)
Fail-safe
mA signal programmable as high,
low or hold (LOE)
Rated operating conditions
Programming
Installation conditions
Handheld programmer
HART communicator 375
PC
SIMATIC PDM
Intrinsically safe Siemens handheld
programmer (optional)
Infrared receiver
• Approvals
(handheld programmer)
ATEX II 1G EEx ia IIC T4
CSA and FM Class I, Div.1,
Groups A,B,C,D, T6 at max.
ambient
Display (local)
Multi-segment alphanumeric
liquid crystal with bar graph
(representing level) available in
four languages
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Installation category
I
• Pollution degree
4
Medium conditions
Dielectric constant εr
εr > 1.6 (for εr < 3, use stillpipe)
Vessel temperature
-40 ... +80 °C (-40 ... +176 °F)
Vessel pressure
3 bar g (43.5 psi g)
Design
Enclosure
• Body construction
PBT (Polybutylene Terephthalate)
• Lid construction
PEI (Polyether Imide)
• Cable inlet
2 x M20x1.5 or
2 x ½" NPT with adapter
Degree of protection
Type 4X/NEMA 4X,
Type 6/NEMA 6, IP67, IP68
Weight
1.97 kg (4.35 lb)
Antenna
• Material
Polypropylene rod, hermetically
sealed construction
• Dimensions
Standard 100 mm (4 inch) shield
for maximum 100 mm (4 inch)
nozzle or optional 250 mm
(10 inch) long shield
Process connections
1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
5/206
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS Probe LR
Selection and Ordering data
C)
SITRANS Probe LR
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in storage vessels with nominal pressure and
temperature, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F)
Enclosure/Cable inlet
Plastic, (PBT), 2 x ½" NPT
Plastic, (PBT), 2 x M20x1.5
Antenna type/Material - (max. 3 bar and 80 °C)
Polyproylene Antenna
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 100 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 100 mm shield
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 250 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 250 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 250 mm shield
Approvals
General Purpose, CE, R&TTE, C-TICK
General Purpose, CSAus/c, FM, FCC
CSA Class I, Div 1, Groups A, B, C, D, Class II,
Div. 1 Group G, Class III, FCC, Intrinsically Safe1)
FM, Class I, II and III, Div 1, Groups A, B, C, D, E, F, G,
FCC, Intrinsically Safe1)
ATEX II 1G EEx ia IIC T4, R&TTE, C-TICK,
Intrinsically Safe1)
Communication/Output
4 ... 20 mA, HART
1)
Order No.
7ML54307777 0
1
2
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters) specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Order No.
Operating Instructions
A
B
C
D
English
C) 7ML1998-5HR02
French
C) 7ML1998-5HR11
Spanish
C) 7ML1998-5HR21
German
Note: The Operating Instructions should be
ordered as a separate item on the order.
C) 7ML1998-5HR32
E
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
F
Additional Operating Instructions
Multi-language Quick Start manual
C) 7ML1998-5QP81
Optional equipment
A
B
C
Handheld programmer, Intrinsically Safe,
ATEX II 1G, Ex ia
7ML5830-2AH
D
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
E
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
1
Barrier or Intrinsically Safe power supply required for Intrinsically Safe
protection
C) Subject to export regulations AL: N, ECCN: EAR99.
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F)
7ML1930-1AP
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Spare parts
Plastic lid
7ML1830-1KB
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/207
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS Probe LR
■ Dimensional drawings
½" NPT cable entry
(or alternatively M20 x 1.5)
lid
lid screws
enclosure /
electronics
locking collar
mounting thread
1½" NPT,
R 1½" BSPT,
23 (0.9)
G 1½" BSPP
inactive shield length
(internal)
standard: 100 (4)
optional: 250 (10)
polypropylene
rod antenna
103,5
(4)
134
(5.3)
139
(5.5)
std. 115 (4.5)
[optional 268 (10.5)]
5
std.: 273 (10.8) min.
option: 423 (16.7) max.
std.: 552 (21.7) min.
option: 702 (27.6) max.
129
(5.1)
SITRANS Probe LR, dimensions in mm (inch)
■ Schematics
Hand Programmer
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
strain relief
(or NPT cable inlet)
SITRANS Probe LR
Part number: 7ML5830-2AH
Notes:
-
DC terminal shall be supplied from an SELV source in accordance with IEC-1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Use shielded twisted pair cable (14-22 AWG)
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS Probe LR connections
5/208
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
■ Overview
■ Configuration
Installation
min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• Beam angle for horn antenna
dependent on horn size
• The peak energy density is
directly in front of and in line
with the rod antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (65 ft).
beam
angle 28°
Mounting unit on vessel
5
■ Benefits
■ Application
SITRANS LR200’s unique design allows safe and simple
programming using the Intrinsically Safe handheld
programmer without having to open the instrument’s lid. It also
features a built-in alphanumeric display in four languages.
Conical
Flat
Parabolic
Mounting unit on stilling well
Mounting on a nozzle
Orient front or
back of device
toward stillpipe
slots.
min. 10 (0.4)
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression
of fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM
The SITRANS LR200 has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance
and is hermetically sealed. The Uni-Construction antenna
features an internal, integrated shield that eliminates vessel
nozzle interference.
Start-up is easy with as few as two parameters for basic operation. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up
with conduit or wiring connections or simply to adjust the
position for easy viewing. SITRANS LR200 features patented
Process Intelligence signal-processing technology for superior
reliability.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, asphalt,
digesters
SITRANS LR200 installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/209
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
■ Technical specifications
Mode of operation
Design
Measuring principle
Radar level measurement
Enclosure
Frequency
5.8 GHz (North America 6.3 GHz)
• Material
Measuring range
0.3 ... 20 m (1.0 ... 65 ft)
Aluminium, polyester powder
coated
• Cable inlet
2 x M20x1.5 or
2 x ½" NPT with adapter
Degree of protection
Type 4X/NEMA 4X,
Type 6/ NEMA 6, IP67, IP68
Output
• Analog output
4 ... 20 mA
• Accuracy
± 0.02 mA
• Span
Proportional or inversely
proportional
Weight
< 2 kg (4.4 lb)
(polypropylene rod antenna)
• Communications
HART
Optional: PROFIBUS PA
(Profile 3.0, Class B)
Display (local)
Multi-segment alphanumeric
liquid crystal with bar graph
(representing level) available in
four languages
• Fail-safe
Programmable as high, low or
hold (Loss of Echo)
Performance
(according to reference
conditions IEC60770-1)
5
• From end of antenna to 600 mm:
40 mm (1.57 inch)
• Remainder of range:
10 mm (0.4 inch) or 0.1% of span
(whichever is greater)
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Installation category
I
• Pollution degree
4
Medium conditions
• Dielectric constant εr
• Vessel temperature and pressure
εr > 1.6 (for εr < 3, use waveguide antenna or stillpipe)
Varies with connection type;
see Pressure/Temperature curves
for more information
Antenna
• Material
Polypropylene rod, hermetically
sealed construction, optional
PTFE
• Dimensions
Standard 100 mm (4 inch) shield
for maximum 100 mm (4 inch)
nozzle, or optional 250 mm
(10 inch) long shield
• Optional rods, horn and
waveguides
Refer to SITRANS LR200
Antennas for optional rods, horns
and waveguides
Process connections
• Process connection
1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226], or
G 1½" [(BSPP), EN ISO 228-1]
(polypropylene rod antenna)
• Flange connection
Refer to SITRANS LR200 Antennas for more connections
Power supply
4 ... 20 mA/HART
- General Purpose, Non-incendive, Intrinsically Safe
Nominal 24 V DC (max. 30 V DC)
with max. 550 Ω
- Flame proof, Increased safety,
Explosion proof
Nominal 24 V DC (max. 30 V DC)
with max. 250 Ω
PROFIBUS PA
5/210
Siemens FI 01 · 2012
• 10.5 mA
• per IEC 61158-2
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Certificates and approvals
General
CSAUS/C, CE, FM, C-TICK, KC
Marine
• Lloyd’s Register of Shipping
• ABS Type Approval
Radio
FCC, Industry Canada and
European (R&TTE), C-TICK
Hazardous
• Flame proof (Europe)
ATEX II 1/2 G Ex dmbia IIC T4
• Increased safety (Europe)
ATEX II 1/2 G Ex embia IIC T4
• Flameproof/Increased Safety
(China)
NEPSI Ex dmbia IIC T4/ Ex embia
IIC T4
• Explosion proof (USA/Canada)
CSA/FM, Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III, T4
• Intrinsically Safe (Europe)
ATEX II 1G Ex ia IIC T4
• Intrinsically Safe (USA/Canada)
CSA/FM, Class I, Div. 1,
Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G; Class III, T4
• Non-incendive (USA)
FM, Class I, Div. 2,
Groups A, B, C, D, T5
• Intrinsically Safe (Australia)
ANZEx Ex ia IIC T4
• Intrinsically Safe (International)
IECEx Ex ia IIC T4
• Intrinsically Safe (Brazil)
INMETRO BR Ex ia IIC T4
5
Programming
• Intrinsically Safe Siemens
handheld programmer
- Approvals for handheld
programmer
Infrared receiver
• Handheld communicator
HART communicator 375
• SIMATIC PDM
• AMS
• PC
• Display (local)
IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T = 135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, and III,
Div. 1., Groups A, B, C, D, E, F, G,
T6 Ta = 50 °C
Multi-segment alphanumeric
liquid crystal with bar graph
(representing level) available in
four languages
Siemens FI 01 · 2012
5/211
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Selection and Ordering data
Order No.
SITRANS LR200, Uni-Construction
C) 7ML5422polypropylene rod antenna version
777 7 0
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F)
Enclosure/Cable inlet
Aluminum, epoxy painted
2 x ½" NPT, Siemens LUI interface
2 x M20x1.5, Siemens LUI interface
5
Polypropylene antenna type (Max. 3 Bar pressure and 80 °C)
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 100 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 100 mm shield
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 250 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 250 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 250 mm shield
Approvals
General Purpose, CE, R&TTE, C-TICK, KC
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div 1,
Gr. A,B,C,D, E,F,G, Industry Canada
2
3
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification (max. 27
characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
Order No.
Operating Instructions for HART/mA device
English
A
C) 7ML1998-5JP02
C) 7ML1998-5JP32
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
B
C
C) 7ML1998-5XC82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
D
E
Operating Instructions for PROFIBUS PA device
F
English
C) 7ML1998-5JR02
C) 7ML1998-5JR32
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
A
B
C
C) 7ML1998-5XD82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Intrinsically Safe, FM Class I, II, Div 1, Gr. A,B,C,D,
E,F,G, FCC
Intrinsically Safe, IECEx/ANZEx/ATEX II 1G Ex ia
IIC T4, INMETRO BR-Ex ia IIC T4, CE, R&TTE,
C-TICK, KC
Non incendive, FM Class I, Div 2, Gr. A,B,C,D,
FCC1)
D
Handheld programmer, Intrinsically safe, EEx ia
C) 7ML1930-1BK
F
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
Increased Safety, ATEX II 1/2G Ex embia IIC T4,
CE, R&TTE, C-TICK, KC2)3)
Flame Proof, ATEX II 1/2G Ex dmbia IIC T4, CE,
R&TTE, C-TICK, KC3)
Explosion Proof, CSA/FM Class I, II, III,
Gr. A,B,C,D,E,F,G, Industry Canada, FCC1)3)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
G
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
1)
Available with enclosure option 2 only
2)
Available with enclosure option 3 only
3)
Available with communication option 3 only
C) Subject to export regulations AL: N, ECCN: EAR99.
E
Accessories
H
J
2
3
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA2)
7ML1930-1AQ
One general purpose polymeric cable gland
M20x1.5, rated -20 ... + 80°C (-40 ... +176 °F)
7ML1930-1AM
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
2)
Available with communication option 3 only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/212
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Selection and Ordering data
SITRANS LR200, Flange Adapter,
C)
Sanitary Version
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Antenna material (uses antenna adapter)
PTFE, one piece rod antenna
UHMW-PE, one piece rod antenna
Process connection
Sanitary fitting clamp
Configuration/Connection size
2" connection, rod antenna only
3" connection, rod antenna only
4" connection, rod antenna only
Antenna extension
No extension
Mounting Clamp
No mounting clamp
Mounting clamp included, not available with
Pressure rating option 0
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT, Siemens LUI interface
2 x M20x1.5, Siemens LUI interface
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
Approvals
General Purpose, CE1)
General Purpose, CSAUS/C, FM,
for North America only2)
CSA Class I and II, Div. I,
Groups A, B, C, D, G, for North America only,
Intrinsically Safe with suitable barrier2)
FM, Class I and II, Div. I,
Groups A, B, C, D, E, F, G, for North America only,
Intrinsically Safe with suitable barrier2)
ATEX II 1G EEx ia IIC T4,
Intrinsically Safe with suitable barrier1)
FM, Class I, Div. 2,
Groups A, B, C, D, FCC 6.3 GHz,
for North America only (no barrier required)3)
ATEX II 1/2 G EEx emia IIC T4
(no barrier required)1)4)5)
ATEX II 1/2 G EEx dmia IIC T4
(no barrier required)1)5)
CSA/FM Class I, II and III, Div. 1,
Groups A, B, C, D, E, F, G
(no barrier required)2)3)5)
Order No.
7ML5424-
Selection and Ordering data
77 7 77 - 777 7
Please add "-Z" to Order No. and specify Order
code(s).
0
1
A
A
B
C
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification (max. 27
characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
0
0
1
C)
C)
English
C) 7ML1998-5JP02
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5JP32
C) 7ML1998-5XC82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
2
3
Operating Instructions for PROFIBUS PA device
B
C
C)
A
B
C)
C
English
C) 7ML1998-5JR02
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5JR32
C) 7ML1998-5XD82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
C)
D
E
C)
F
C) 7ML1930-1BK
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA2)
7ML1930-1AQ
H
J
SITRANS RD100 Remote display - see Chapter 8
G
C)
Handheld programmer, Intrinsically safe, EEx ia
SITRANS RD200 Remote display - see Chapter 8
0
1
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
Includes Radio approval FCC, 6.3 GHz
3)
Available with enclosure option 2 only
4)
Available with enclosure option 3 only
5) Available with communication option C only
Sanitary fitting clamps
C) Subject to export regulations AL: N, ECCN: EAR99.
1)
2)
Order No.
Operating Instructions for HART/mA device
Pressure rating
Rating per Pressure/Temperature curves in Manual
0.5 bar g (7.25 psi g) maximum
1)
Order code
Further designs
2", 304 stainless steel
7ML1830-1HD
3", 304 stainless steel
7ML1830-1HE
4", 304 stainless steel
7ML1830-1HF
2)
Available with communication option C only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/213
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
t
5
Selection and Ordering data
D)
SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Antenna material (uses antenna adapter)
PTFE, uses antenna adapter and
additional process connection below
Process connection (refer to Pressure/Temperature curves in Operating Instructions)
Flanges (316L stainless steel)
DN 50 PN 16, Type A, flat faced
DN 80 PN 16, Type A, flat faced
DN 100 PN 16, Type A, flat faced
DN 150 PN 16, Type A, flat faced
2" ASME 150 lb, flat faced
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
DN 50 PN 40, flat faced
DN 80 PN 40, flat faced
DN 100 PN 40, flat faced
DN 150 PN 40, flat faced
2" ASME 300 lb, flat faced, available with
Pressure rating option 1 only
3" ASME 300 lb, flat faced
4" ASME 300 lb, flat faced
6" ASME 300 lb, flat faced
JIS DN 50 10K
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2220 standard.)
Threaded connection (316L stainless steel)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226]
R 2" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
G 2" [(BSPP), EN ISO 228-1]
Antenna extensions or Inactive shield length
No antenna extension
50 mm (2 inch) extension, PTFE
100 mm (4 inch) extension, PTFE
100 mm (4 inch) extension,
316L stainless steel shield1)
150 mm (6 inch) extension,
316L stainless steel shield1)
200 mm (8 inch) extension,
316L stainless steel shield1)
250 mm (10 inch) extension,
316L stainless steel shield1)
Process seal/gasket
Integral Gasket,
for flat faced flange process connections only,
not for Antenna extension options 3 ... 6
FKM O-ring,
not available for combination of flat faced flanges
with Antenna extension options 0, 1 or 2
Enclosure/Cable inlet
Aluminum, Epoxy painted
C)
2 x ½" NPT, Siemens LUI interface
C)
2 x M20x1.5, Siemens LUI interface
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
5/214
Siemens FI 01 · 2012
Order No.
7ML542377 7 77 - 777 7
1
AA
BA
CA
DA
FB
GB
HB
JB
AC
BC
CC
DC
FD
GD
HD
JD
AE
BE
CE
DE
Selection and Ordering data
Order No.
D) 7ML5423SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
77 7 77 - 777 7
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Approvals
General Purpose, CE2)
A
General Purpose, CSAUS/C,
B
3)
FM, for North America only
CSA Class I and II, Div. I,
C
Groups A, B, C, D, G, for North America only,
3)
Intrinsically Safe with suitable barrier
FM, Class I and II, Div. I,
D
Groups A, B, C, D, E, F, G, for North America only,
3)
Intrinsically Safe with suitable barrier
ATEX II 1G EEx ia IIC T4,
E
Intrinsically Safe with suitable barrier2)
FM, Class I, Div. 2,
F
Groups A, B, C, D, FCC 6.3 GHz,
3)4)
for North America only (no barrier required)
ATEX II 1/2 G EEx emia IIC T4
G
(no barrier required)2)5)6)
ATEX II 1/2 G EEx dmia IIC T4
H
(no barrier required)2)6)
CSA/FM Class I, II and III, Div. 1,
J
Groups A,B, C, D, E, F, G (no barrier required)2)4)6)
Pressure rating
Rating per Pressure/Temperature curves in manual
0
0.5 bar g (7.25 psi g) maximum
1
1)
2)
3)
4)
5)
6)
LA
MA
LC
MC
LE
ME
Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
Includes Radio approval FCC, 6.3 GHz
Available with enclosure option 2 only
Available with enclosure option 3 only
Available with communication option C only
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
0
1
2
3
4
5
6
0
1
2
3
B
C
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
Order No.
Operating Instructions for HART/mA device
English
C) 7ML1998-5JP02
C) 7ML1998-5JP32
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
C) 7ML1998-5XC82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
5
Operating Instructions for PROFIBUS PA device
English
C) 7ML1998-5JR02
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5JR32
C) 7ML1998-5XD82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia
C) 7ML1930-1BK
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA2)
7ML1930-1AQ
Antenna, rod, PTFE
7ML1830-1HC
Antenna extension, 50 mm (2 inch) PTFE
7ML1830-1CH
Antenna extension, 100 mm (4 inch) PTFE
7ML1830-1CG
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
Available with communication option 3 only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
2)
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/215
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Selection and Ordering data
C)
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Antenna material (uses antenna adapter)
316L stainless steel with PTFE cone emitter
316L stainless steel with PTFE cone emitter and
purge connection with 1/8" NPT inlet1)
Sliding waveguide system with 1000 mm (40 inch)
waveguide1)2)
Process connection (refer to Pressure/Temperature curves on specification sheets)
Flanges (316L stainless steel)
DN 50 PN 16, Type A, flat faced1)
DN 80 PN 16, Type A, flat faced
DN 100 PN 16, Type A, flat faced
DN 150 PN 16, Type A, flat faced
DN 200 PN 16, Type A, flat faced
DN 80 PN 10/16 DIN EN1092-1 form B13)
DN 100 PN 10/16 DIN EN1092-1 form B13)
DN 150 PN 10/16 DIN EN1092-1 form B13)
DN 200 PN 16 DIN EN1092-1 form B13)
5
Order No.
7ML54257 7 7 77 - 777 7
0
1
2
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT, Siemens LUI interface
2 x M20x1.5, Siemens LUI interface
AA
BA
CA
DA
EA
BF
CF
DF
2" ASME 150 lb, flat faced1)
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
8" ASME 150 lb, flat faced
EF
FB
GB
HB
JB
KB
DN 50 PN 40, flat faced1)3)
DN 80 PN 40, flat faced3)
DN 100 PN 40, flat faced3)
DN 200 PN 40, flat faced3)
AC
BC
CC
EC
DN 80 PN 25/40 DIN EN1092-1 form B13)
DN 100 PN 25/40 DIN EN1092-1 form B13)
DN 150 PN 25/40 DIN EN1092-1 form B13)
2" ASME 300 lb, flat faced1)3)
3" ASME 300 lb, flat faced3)
4" ASME 300 lb, flat faced3)
CG
DG
EG
FD
GD
HD
10K1)
JIS DN 50
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
JIS DN 200 10K
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2220 standard.)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
5/216
Siemens FI 01 · 2012
Selection and Ordering data
Order No.
C) 7ML5425SITRANS LR200,
Flange adapter/Horn Antenna version
77 7 77 - 777 7
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Process seal/gasket
FKM (-40 ... +200 °C)
0
Nitrile (-40 ... +60 °C),
1
sliding waveguide sytems only
FFKM (-35 ... +200 °C)
2
Horn size/Waveguide options
80 mm (3 inch) horn4)
100 mm (4 inch) horn4)
150 (6 inch) mm horn
200 (8 inch) mm horn
100 mm (4 inch) horn with 100 mm (4 inch)
waveguide extension4)
100 mm (4 inch) horn with 150 mm (6 inch)
waveguide extension4)
100 mm (4 inch) horn with 200 mm (8 inch)
wave-guide extension4)
AE
BE
CE
DE
EE
B
C
D
E
F
G
H
100 mm (4 inch) horn with 250 mm (10 inch)
waveguide extension4)
J
150 mm (6 inch) horn with 100 mm (4 inch)
waveguide extension
150 mm (6 inch) horn with 150 mm (6 inch)
waveguide extension
150 mm (6 inch) horn with 200 mm (8 inch)
waveguide extension
150 mm (6 inch) horn with 250 mm (10 inch)
waveguide extension
200 mm (8 inch) horn with 100 mm (4 inch)
waveguide extension
200 mm (8 inch) horn with 150 mm (6 inch)
waveguide extension
K
200 mm (8 inch) horn with 200 mm (8 inch)
waveguide extension
200 mm (8 inch) horn with 250 mm (10 inch)
waveguide extension
Waveguide only - Waveguide length
500 mm ... 3000 mm (in 1 mm increments)
(Add order code Y01 and plain text:
"waveguide length ... mm inch)
1
2
2
3
L
M
N
P
Q
R
S
T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
Selection and Ordering data
Order No.
C) 7ML5425SITRANS LR200,
Flange adapter/Horn Antenna version
7 7 7 77 - 777 7
2-wire, 6 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft).
Approvals
General Purpose, CE5)
A
General Purpose, CSAUS/C,
B
FM, for North America only6)
CSA Class I and II, Div. I,
C
Groups A, B, C, D, G, for North America only,
Intrinsically Safe with suitable barrier6)
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Inactive custom shield lengths: Enter the total
length of the inactive shield in plain text description
(in 1 mm increments).
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
FM, Class I and II, Div. I,
Groups A, B, C, D, E, F, G, for North America only,
Intrinsically Safe with suitable barrier6)
ATEX II 1G EEx ia IIC T4,
Intrinsically Safe with suitable barrier5)
FM, Class I, Div. 2,
Groups A, B, C, D, for North America only
(no barrier required)6)7)
D
F
English
C) 7ML1998-5JP02
G
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5JP32
ATEX II 1/2 G EEx emia IIC T4
(no barrier required)5)8)9)
ATEX II 1/2 G EEx dmia IIC T4
(no barrier required)5)9)
CSA/FM Class I, II and III, Div. 1,
Groups A B, C, D, E, F, G (no barrier required)6)7)9)
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
1)
2)
3)
4)
5)
6)
7)
8)
9)
Available with pressure rating option 1 only
Maximum Process Temperature 60 °C (140 °F)
Available with Antenna Material option 0 and 1 only
For stillpipe applications only
Includes European Radio approval (R&TTE), 5.8 GHz, C-TICK
Includes Radio approval FCC, 6.3 GHz
Available with enclosure option 2 only
Available with enclosure option 3 only
Available with communication option 2 only
E
Order No.
Operating Instructions for HART/mA device
H
C) 7ML1998-5XC82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
J
0
1
Operating Instructions for PROFIBUS PA device
English
C) 7ML1998-5JR02
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5JR32
C) 7ML1998-5XD82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
C) Subject to export regulations AL: N, ECCN: EAR99.
Handheld programmer, Intrinsically safe, EEx ia
C) 7ML1930-1BK
D) Subject to export regulations AL: N, ECCN: EAR99H.
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA3)
7ML1930-1AQ
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA000
see Chapter 8
1)
2)
Available with communication option 2 only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
3)
Available with enclosure option 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/217
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
■ Dimensional drawings
SITRANS LR200 with Polypropylene
Shielded Rod Antenna
PTFE Rod Antenna, Threaded
Threaded Connection
PTFE Rod, external shield
½" NPT cable entry
(or alternatively M20 x 1.5 cable gland)
Nameplate
Nameplate
Threaded cover
187 (7.4)
154
(6)
Reference point
AISI 316,
2" NPT,
R 2" (BSPT)
or G 2" (BSPP)
185
(7.3)
Enclosure/
Electronics
158
(6.1)
PTFE
antenna
Locking ring
412
(16.3)
Reference point
Std. 296 (11.7) min.
Option: 446 (17.6) max.
5
Mounting
thread
187
(7.4)
Reference point
AISI 316,
17
2" NPT,
(0.67)
R 2" (BSPT)
or G 2" (BSPP)
Antenna shield
(inactive length)
AISI 316
18
(0.7)
S.L.
Active antenna
(PTFE)
L
Shield Length (S.L.):
min. 100 (4)
(customer specified)
Overall Length (L):
374 (14.7) plus
shielded length
Shield length (internal):
Standard: 100 (4)
Optional: 250 (10)
Polypropylene
rod antenna
Std. 575 (22.6) min.
Option: 725 (28.5) max.
Horn Antenna with Flat Faced Flange
enclosure/electronics
Nameplate
187
(7.4)
Locking ring
Reference point
Flange
Ø80 (3)
horn
Waveguide Antenna with
Flat Faced Flange
Sliding Waveguide
13
(5.16)
100
(4)
225.8
(8.89)
325.1
(12.79)
150 (6)
200 (8)
Nameplate
Nameplate
187
(7.4)
Reference
point
187
(7.4)
Sanitary Rod Antenna
Reference point
40
(1.6)
40 (1.6)
Nameplate
Sliding flange
187 (7.4)
41.4
(1.69)
Reference point
1000
(40.8)
Waveguide
131
(5.16)
100 (4)
150 (6)
76.2
(3.0)
SITRANS LR200, dimensions in mm (inch)
5/218
20 (0.8)
variable
min: 100 (4)
max: 3000 (123)
Siemens FI 01 · 2012
200 (8)
225.8
(8.89)
406 (16)
nominal
325.1
(12.8)
Clamp
(optional)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
■ Schematics
Hand Programmer
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
gland
Shield for HART and
PROFIBUS PA
Instrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
1.
2.
3.
4.
5
DC terminal shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Use shielded twisted pair cable (14 to 22 AWG) for HART version.
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR200 connections
Siemens FI 01 · 2012
5/219
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200 Antennas
■ Integration
Horn with waveguide
extension. Used for high
temperature isolation, long
standpipes, and clearing
tank obstructions.
5
Flat faced flange
connection with
PTFE rod antenna.
Shielded rod antenna
with a stainless steel
shield eliminates
standpipe interference.
Various lengths
available.
Sanitary rod
connection for food
applications. 2", 3",
or 4" sizes available.
Waveguide antenna
for low dielectric products.
Custom lengths available.
Sliding waveguide antenna,
typically for digester applications
that include an isolation valve
between the instrument and the vessel.
Sanitary clamps and ferrules
(shown respectively) are
available for sanitary connection
types (only for ambient pressure
applications).
SITRANS LR200 with flange
adapter for connection to
optional antennas.
Antenna configurations for SITRANS LR200
■ Technical specifications
Antenna Types
Flat Faced Flange with Shielded Rod
Rod
Connection type
Flat faced flange
nominal pipe sizes 50,
80, 100, 150 mm
(2, 3, 4, 6 inch)
Threaded 2" NPT, R 2" Sanitary fitting clamp
(BSPT), G 2" (BSPP) or 50, 80, 100 mm
flat faced flange
(2, 3, 4 inch) sizes
nominal pipe sizes 80,
100 mm (3, 4 inch)
Flat faced flange
nominal pipe sizes 50,
80, 100, 150 mm
(2, 3, 4, 6 inch)
Flat faced flange
nominal pipe sizes 50,
80, 100, 150 mm
(2, 3, 4, 6 inch)
Wetted parts
PTFE
PTFE, 316L stainless
steel, FKM o-ring
UHME-PE or PTFE
316L stainless steel
PTFE, FKM o-ring
316L stainless steel
PTFE, FKM o-ring
Extensions
50 or 100 mm
(2 or 4 inch)
PTFE or UHMW-PE
100, 150, 200 or
250 mm (4, 6, 8 or
10 inch)
standard shield length
N/A
use waveguide for
two sections (max.) can
extensions to 6 m (20 ft) be connected together
long
Max. overall length:
3 m (9.8 ft)
Dielectric constant
>3
>3
>3
>3
variable
41 cm (16.3 inch)
variable with extension variable
Insertion length (max.) 41 cm (16.3 inch)
Sanitary Rod
Horn (4", 6", 8" sizes
(1 piece construction) available)
Waveguide
> 1.6
Purging option
(liquid or gas)
No
No
No
Yes
Yes
Sliding waveguide
option for digesters1)
Yes
No
No
Yes
N/A
Weight2)
6.5 kg (14.3 lb)
5.0 kg (11 lb)
5.0 kg (11 lb)
7.5 kg (16.5 lb)
8.0 kg (17.6 lb)
1 m (39 inch) length
1)
2)
Maximum pressure 0.5 bar g at 60 °C (7.25 psi g at 140 °F)
Not including extensions, includes SITRANS LR200 and smallest process connection
5/220
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
■ Characteristic curves
Ambient temperature (°C)
Maximum Flange and Process Temperatures versus Allowable Ambient Temperature
90
80
70
60
50
Polypropylene rod
40
PTFE rod/
horn antenna
30
20
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Process Flange Surface Temperature (°C)
SITRANS LR200 Ambient/Process Flange Surface Temperature Curve
5
Siemens FI 01 · 2012
5/221
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200
PTFE Rod Antenna with
Integral Gasket 150# and PN 16 Sizes
Flange Series 22452, 316 Stainless Steel, Flat Face
16.0
Pressure (bar, gauge)
14.0
(A)
(B)
12.0
10.0
(C)
8.0
6.0
4.0
(A) 22452 50 mm/2" nom.
2.0
(B) 22452 80 mm/3" nom.
0.0
-40 -20
(C) 22452 100 mm/4" nom.
0
20
40
60 80 100 120 140 160 180 200
Temperature (°C)
Horn Antenna and/or Wave Guide with
PTFE Ermitter 150# and PN 16 Sizes
Flange Series 22452, 316 Stainless Steel, Flat Face
5
16.0
(E)
Pressure (bar, gauge)
14.0
(D)
12.0
10.0
(F)
8.0
6.0
(D) 22452 80 mm/3" nom.
(G)
4.0
(E) 22452 100 mm/4" nom.
2.0
(F) 22452 150 mm/6" nom.
0.0
-50
(G) 22452 200 mm/8" nom.
0
50
100
Temperature (°C)
150
200
Threaded Process and Sanitary Process Connections
1.5" & 2" NPT, BSP, & G Sanitary Tri-clamp 2", 3", & 4"
40.0
Pressure (bar, gauge)
35.0
30.0
UHMW-PE is limited to 80 °C, it can be used to 120 °C for
short (3 hrs) durations at ambient pressure, no stress
applied to the antenna.
25.0
20.0
15.0
10.0
(I)
(H) 1,5" and 2", Thread connection
(J)
(H)
(I) UHMW-PE, Sanitary antenna
5.0
0.0
-50
(J) PTFE, Sanitary antenna
0
50
100
Temperature (°C)
150
200
SITRANS LR200 Process Pressure/Temperature derating curves
5/222
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Order No.
SITRANS LR200 PROFIBUS PA Aluminum
Enclosure Kit with electronics and covers
(7ML5422, 7ML5423, 7ML5424, 7ML5425),
calibrated for use with standard rod antenna
SITRANS LR200 aluminum enclosure
C) A5E01483420
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.
See note 5.
SITRANS LR200 aluminum enclosure
C) A5E01483440
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with PROFIBUS
PA communication, no process connection.
See note 5.
SITRANS LR200 aluminum enclosure
C) A5E01483456
with board stack, LUI display, 6.3 GHz, M20
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.
See note 5.
Order No.
SITRANS LR200 aluminum enclosure
C) A5E03617085
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option A, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E03617086
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option B, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E03617087
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option C, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E03617088
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option E, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 Horn Antenna Kits
with mounting screws
(no emitter supplied)
5
SITRANS LR200 aluminum enclosure
C) A5E01483547
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.
See note 5.
SITRANS LR200 aluminum enclosure
C) A5E01483559
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.
See note 5.
SITRANS LR200 HART aluminum enclosure
kit with electronics and covers (7ML5422,
7ML5423, 7ML5424, 7ML5425), calibrated for
use with
standard rod antenna
SITRANS LR200 aluminum enclosure
C) A5E02956419
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E02956420
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E02956421
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option G, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
SITRANS LR200 aluminum enclosure
C) A5E02956422
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option H, with HART communication start-up at < 3.6 mA, no process
connection. See note 5.
80 mm (3 inch) horn antenna kit
PBD-25500K02A
100 mm (4 inch) horn antenna kit
PBD-25500K03A
150 mm (6 inch) horn antenna kit
PBD-25500K05A
200 mm (8 inch) horn antenna kit
PBD-25500K07A
SITRANS LR200 Extension Kits for
Horn Antenna with mounting screws
100 mm (4 inch) extension kit for horn antenna
PBD-25501K0100A
150 mm (6 inch) extension kit for horn antenna
PBD-25501K0150A
200 mm (8 inch) extension kit for horn antenna
PBD-25501K0200A
250 mm (10 inch) extension kit for horn antenna
PBD-25501K0250A
500 mm (20 inch) extension kit for horn antenna
PBD-25501K0500A
1000 mm (40 inch) extension kit for
horn antenna
PBD-25501K1000A
SITRANS LR200 Flanged Rod Antenna Kit
with 316L SS flat faced flanges
Flanged PTFE rod antenna kit, 2" ASME, 150 lb.
See drawing 51003 on
http://www.siemens.com/radar.
See notes 1 and 4.
PBD51003K020AAAA
Flanged PTFE rod antenna kit, DN 50 PN16.
See drawing 51003 on
http://www.siemens.com/radar.
See notes 1 and 4.
PBD51003K050AJAA
Flanged PTFE rod antenna kit,
JIS 10K DN 50. See drawing 51003 on
http://www.siemens.com/radar.
See notes 1 and 4.
PBD51003K050AOAA
Siemens FI 01 · 2012
5/223
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Order No.
SITRANS LR200 PTFE Rod Antenna Kit with
316L SS 1½" pipe thread process connection
5
Order No.
SITRANS LR200 PTFE Rod Antenna Kit (100
mm shield) with 316L SS 2" pipe thread process connection
PTFE rod antenna kit, 1½" NPT 316L SS Process Connection, FKM O-ring;
See drawing 51004 on
http://www.siemens.com/radar.
See note 4.
PBD-51004K1AAA
PTFE rod antenna kit, R 1½" (BSPT), EN 10226
316L SS Process Connection, FKM O-ring; See
drawing 51004 on
http://www.siemens.com/radar.
See note 4.
PBD-51004K2AAA
PTFE rod antenna kit, 1½" G 316L SS Process
Connection, FKM O-ring;
See drawing 51004 on
http://www.siemens.com/radar.
See note 4.
PBD-51004K3AAA
SITRANS LR200 PTFE Rod Antenna Kit with
316L SS 2" pipe thread process connection
PTFE rod antenna shielded kit, 2" NPT 316L SS
Process Connection, FKM O-ring, 100 mm
316L SS shield.
See drawing 51002 on
http://www.siemens.com/radar.
See notes 3 and 4.
PBD51002K0100AAA
PTFE rod antenna shielded kit, R 2" (BSPT),
EN 10226 316L SS Process Connection,
FKM O-ring, 100 mm 316L SS shield.
See drawing 51002 on
http://www.siemens.com/radar.
See notes 3 and 4.
PBD51002K0100BAA
PTFE rod antenna shielded kit, 2" G 316L SS
Process Connection, FKM O-ring,
100 mm 316L SS shield.
See drawing 51002 on
http://www.siemens.com/radar.
See notes 3 and 4.
PBD51002K0100CAA
SITRANS LR200 Horn Antenna Kit with 316L
SS flat faced flange, with PTFE emitter (without waveguide)
PTFE rod antenna kit, 2" NPT 316L SS Process
Connection, FKM O-ring;
See drawing 51005 on
http://www.siemens.com/radar.
See note 4.
PBD-51005K1AAA
PTFE rod antenna kit, R 2" (BSPT), EN 10226
316L SS Process Connection, FKM O-ring; See
drawing 51005 on
http://www.siemens.com/radar.
See note 4.
PBD-51005K2AAA
PTFE rod antenna kit, 2" G 316L SS
Process Connection, FKM O-ring;
See drawing 51005 on
http://www.siemens.com/radar.
See note 4.
PBD-51005K3AAA
5/224
Siemens FI 01 · 2012
Horn antenna kit, 2" ASME 316L SS flange 3"
horn, PTFE emitter; See notes 1 and 4.
PBD51006K020AAAA
Horn antenna kit, 2" ASME 316L SS flange 4"
horn, PTFE emitter; See notes 1 and 2.
PBD51006K020AABA
Horn antenna kit, 2" ASME 316L SS flange 6"
horn, PTFE emitter; See notes 1 and 2.
PBD51006K020AACA
Horn antenna kit, 2" ASME 316L SS flange 8"
horn, PTFE emitter; See notes 1 and 2.
PBD51006K020AADA
Horn antenna kit, DN 50 PN 16 316L SS flange
80 mm horn, PTFE emitter;
See notes 1 and 2.
PBD51006K050AJAA
Horn antenna kit, DN 50 PN 16 316L SS flange
100 mm horn, PTFE emitter;
See notes 1 and 2.
PBD51006K050AJBA
Horn antenna kit, DN 50 PN 16 316L SS flange
150 mm horn, PTFE emitter;
See notes 1 and 2.
PBD51006K050AJCA
Horn antenna kit, DN 50 PN 16 316L SS flange
200 mm horn, PTFE emitter;
See notes 1 and 2.
PBD51006K050AJDA
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Order No.
Order No.
SITRANS LR200 Sanitary Rod Antenna with
Sanitary Fitting Clamp Flange mounting and
bushing.
See drawing 51010 on
PTFE paste
http://www.siemens.com/radar
Cable gland
Kit, PTFE paste, Tube, 250 mL.
See note 5.
(Sanitary Fitting Clamps not included)
C)
PBD-51036065
One polymeric cable gland M20x1.5, rated
-20 ... +80 °C (-4 ... +176 °F) for General
Purpose and ATEX EEx e
7ML1930-1AN
PTFE sanitary rod antenna kit,
2" mounting connection. See note 4.
PBD-51010K1AA
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
PTFE sanitary rod antenna kit,
3" mounting connection. See note 4.
PBD-51010K2AA
7ML1930-1AQ
PTFE sanitary rod antenna kit,
4" mounting connection. See note 4.
PBD-51010K3AA
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA
UHMW-PE sanitary rod antenna kit,
2" mounting connection. See note 4.
PBD-51010K1AB
UHMW-PE sanitary rod antenna kit,
3" mounting connection. See note 4.
PBD-51010K2AB
UHMW-PE sanitary rod antenna kit,
4" mounting connection). See note 4.
PBD-51010K3AB
C) Subject to export regulations AL: N, ECCN: EAR99.
SITRANS LR200 PTFE flanged rod antenna
kit with 316L SS shield and 316L SS flat
faced flange
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L SS flange, 100 mm 316L
SS shield. See notes 1 and 4.
PBD51014K0100AAA
PTFE shielded rod antenna kit, flanged, DN 80
PN 16 316L SS flange, 100 mm 316L SS shield.
See notes 1 and 4.
PBD51014K0100EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L SS flange, 150 mm 316L
SS shield. See notes 1 and 4.
PBD51014K0150AAA
PTFE shielded rod antenna kit, flanged, DN 80
PN 16 316L SS flange, 150 mm 316L SS shield.
See notes 1 and 4.
PBD51014K0150EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L SS flange, 200 mm 316L
SS shield. See notes 1 and 4.
PBD51014K0200AAA
PTFE shielded rod antenna kit, flanged, DN 80
PN 16 316L SS flange, 200 mm 316L SS shield.
See notes 1 and 4.
PBD51014K0200EJA
PTFE shielded rod antenna kit, flanged, 3"
ASME 150 lb 316L SS flange, 250 mm 316L SS
shield. See notes 1 and 4.
PBD51014K0250AAA
PTFE shielded rod antenna kit, flanged, DN 80
PN 16 316L SS flange, 250 mm 316L SS shield.
See notes 1 and 4.
PBD51014K0250EJA
Please contact [email protected] for special requests.
1) Available in flange sizes including ASME, DIN and JIS:
please contact [email protected]
2) Available with no pressure rating
3) Available in other shield lengths:
please contact [email protected]
4) Available with Pressure rating; serial number of original
unit required with completed Application Questionnaire found
on page 5/204
Siemens FI 01 · 2012
5/225
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
■ Overview
■ Configuration
Installation
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the horn antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
Mounting unit on bypass
Orient front or back of
device toward vent.
19°
Mounting unit on
stilling well
Orient front or back of device
toward stillpipe slots.
■ Benefits
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small antennas for easy
mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the antenna
• Communication using HART or PROFIBUS PA, or
FOUNDATION Fieldbus
• Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions
• Programming using infrared Intrinsically Safe handheld programmer or over a network using SIMATIC PDM, Emerson
AMS, or Field Device Tools, such as PACTware or Fieldcare via
SITRANS DTM
• Suitable for use in Ssafety related systems in accordance with
IEC 61508/61511 (SIL-2)
Use largest
horn size
possible in
pipe.
Mounting unit on vessel
Mounting on a nozzle
■ Application
min. 10 (0.4)
5
SITRANS LR250 is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft).
beam width:
1.5 horn = 19°
2.0 horn = 15°
3.0 horn = 10°
4.0 horn = 8°
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to obstructions.
SITRANS LR250’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without saving to open the instrument’s lid.
SITRANS LR250 measures superbly on low dielectric media,
and in small vessels, as well as tall and narrow vessels.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, high temperatures, low
dielectric media
5/226
Siemens FI 01 · 2012
SITRANS LR250 installation, dimensions in mm (inch)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
■ Technical specifications
Antenna
Mode of operation
Measuring principle
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch)
from end of antenna
Maximum measuring range
20 m (65 ft), antenna dependent
Output
HART
Version 5.1
• Analog output
4 ... 20 mA
• Accuracy
± 0.02 mA
• Fail-safe
• Programmable as high low or
hold (loss of echo)
• NE 43 programmable
PROFIBUS PA:
Profile 3.1
• Function blocks
2 Analog Input (AI)
FOUNDATION Fieldbus
H1
• Functionality
Basic or LAS
• Version
ITK 5.2.0
• Function blocks
2 Analog Input (AI)
Performance (according to
reference conditions IEC60770-1)
Maximum measured error
Influence of ambient temperature
• Material
316L stainless steel [optional
alloy N06022/2.4602
(Hastelloy C-22 or equivalent)]
• Dimensions (nominal horn sizes)
Standard 1.5" (40 mm), 2"
(48 mm), 3" (75 mm), 4" (95 mm)
horn and optional 100 mm
(4 inch) horn extension
Process connections
• Process connection
1½" or 2" NPT [(Taper),
ANSI/ASME B1.20.1]
R 1½" or 2" [(BSPT), EN 10226]
G 1½" or 2" [(BSPP),
EN ISO 228-1]
• Flange connection
2", 3", 4" (ANSI 150, 300 lb),
50, 80, 100 mm
(PN 16, 40, JIS 10K)
Power supply
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 Ω
PROFIBUS PA
• 15 mA
• per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• per IEC 61158-2
5 mm (0.2 inch)
Certificates and approvals
< 0.003 %/K
General
CSAUS/C, CE, FM, NE 21,
C-TICK, KC
Radio
FCC, Industry Canada and
Europe ETSI EN 302-372, C-TICK
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Installation category
I
• Pollution degree
4
Medium conditions
Dielectric constant εr
> 1.6, antenna and application
dependent
Process temperature
-40 ... +200 °C (-40 ... +392 °F)
(at process connection with
FKM o-ring)
-20 ... +200 °C (-4 ... +392 °F)
(at process connection with
FFKM o-ring)
Process pressure
5
Up ... 40 bar g (580 psi g),
process connection and
temperature dependent.
See Pressure/Temperature curves
for more information
Hazardous
• Intrinsically Safe (Europe)
ATEX II 1G EEx ia IIC T4
ATEX II 1D EEx tD A20 IP67
T90°C
• Intrinsically Safe (China)
NEPSI Ex ia IIC T4/DIP A20 TA
T90°C IP67
• Non-sparking/
Energy Limited (Europe)
ATEX II 3G EEx nA/nL IIC T4 Gc
• Non-sparking/
Energy Limited (China)
NEPSI Ex nA/nL IIC T4
• Intrinsically Safe (Canada/USA)
CSA/FM Class I, Div. 1, Groups A,
B, C, D; Class II, Div. 1, Groups E,
F, G; Class III T4
• Non-incendive (Canada/USA)
CSA/FM Class I, Div. 2, Groups A,
B, C, D T5
• Intrinsically Safe (International)
IECEx Ex ia IIC T4, Ex tD A20
IP67 T90°C
• Intrinsically Safe (Brazil)
INMETRO Br-Ex ia IIC T4
• Flame Proof (International/Europe)
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex dmbia IIC T4 Ga/Gb, Ex tD
A20 IP67 T90°C
• Explosion Proof (Brazil)
INMETRO Br-Ex dmbia IIC T4
• Increased Safety
(International/Europe)
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex embia IIC T4 Ga/Gb, Ex tD
A20 IP67 T90°C
• Increased Safety (Brazil)
INMETRO Br-Ex embia IIC T4
• Explosion Proof (Canada/USA)
CSA/FM Class I, Div. 1, Groups A,
B, C, D; Class II, Div. 1, Groups E,
F, G; Class III T4
• Increased Safety/
Flameproof (China)
Ex dmbia IIC T4/ Ex embia IIC T4/
DIP A20 TA, T90°C IP67
Design
Enclosure
• Material
Aluminium, polyester powdercoated
• Cable inlet
2 x M20x1.5 or 2 x ½" NPT
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
Weight
< 3 kg (6.6 lb) 3.75 mm (1½")
threaded connection with
1½" horn antenna
Display (local)
Graphic local user interface
including quick start wizard and
echo profile display
Siemens FI 01 · 2012
5/227
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
Marine
• Lloyd’s Register of Shipping
• ABS Type Approval
• Bureau Veritas
Functional Safety
SIL-2 suitable in accordance with
IEC 61508/61511
Programming
• Intrinsically Safe Siemens
handheld programmer
Infrared receiver
• Approvals for handheld
programmer
IS model:
ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1.,
Groups A, B, C, D, E, F, G,
T6 Ta = 50 °C
IECEx SIR 09.0073
Handheld communicator
HART communicator 375/475
PC
• SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection
into FDT, such as PACTware or
Fieldcare)
Display (local)
Graphic local user interface
including quick start wizard and
echo profile displays
5
5/228
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
Selection and Ordering data
C)
SITRANS LR250
2-wire, 25 GHz pulse radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media.
Process Connection and Antenna Material
316L (1.4435 or 1.4404) stainless steel,
PTFE emitter, FKM seal1)
316L (1.4435 or 1.4404) stainless steel,
PTFE emitter, FFKM seal1)
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter,
FKM seal2)
Order No.
7ML5431-
Hastelloy C-22/2.4602 (or equivalent), PTFE emitter,
FFKM seal2)
Process Connection Type
Threaded connection 316L
1½" NPT (ASME B1.20.1) (tapered thread)3)
R 1½" [(BSPT), EN 10226-1] (tapered thread)3)
G 1½" [(BSPP), EN ISO 228-1] (parallel thread)3)
3
7 7 7 7 0 - 777 7
0
1
2
AA
AB
AC
AD
AE
AF
2" NPT (ASME B1.20.1) (tapered thread)
R 2" [(BSPT), EN 10226-1] (tapered thread)
G 2" [(BSPP), EN ISO 228-1] (parallel thread)
Flanged connection 316L
2" Class 150 ASME B16.5 flat faced4)
3" Class 150 ASME B16.5 flat faced4)
4" Class 150 ASME B16.5 flat faced4)
2" Class 300 ASME B16.5 flat faced4)
3" Class 300 ASME B16.5 flat faced4)
4" Class 300 ASME B16.5 flat faced4)
BA
BB
BC
CA
CB
CC
DN 50 PN 16 EN 1092-1 Type A flat faced4)
DN 80 PN 16 EN 1092-1 Type A flat faced4)
DN 100 PN 16 EN 1092-1 Type A flat faced4)
DN 50 PN 40 EN 1092-1 Type A flat faced4)
DN 80 PN 40 EN 1092-1 Type A flat faced4)
DN 100 PN 40 EN 1092-1 Type A flat faced4)
DA
DB
DC
EA
EB
EC
50A 10K JIS B 2220 flat faced4)
80A 10K JIS B 2220 flat faced4)
100A 10K JIS B 2220 flat faced4)
FA
FB
FC
DN 50 PN 16 DIN EN1092-1 Type B1 raised face
DN 80 PN 16 DIN EN1092-1 Type B1 raised face
DN 100 PN 16 DIN EN1092-1 Type B1 raised face
DN 150 PN 16 DIN EN1092-1 Type B1 raised face
DN 50 PN 40 DIN EN1092-1 Type B1 raised face
DN 80 PN 40 DIN EN1092-1 Type B1 raised face
GA
GB
GC
GD
HA
HB
DN 100 PN 40 DIN EN1092-1 Type B1 raised face
DN 150 PN 40 DIN EN1092-1 Type B1 raised face
HC
HD
Selection and Ordering data
Order No.
C) 7ML5431SITRANS LR250
2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 7 0 - 7 7 7 7
tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media.
Flanged connection Hastelloy C
2" Class 150 ASME B16.5 raised faced4)
JA
3" Class 150 ASME B16.5 raised faced4)
JB
4" Class 150 ASME B16.5 raised faced4)
JC
2" Class 300 ASME B16.5 raised faced4)
3" Class 300 ASME B16.5 raised faced4)
4" Class 300 ASME B16.5 raised faced4)
DN 50 PN 16 EN 1092-1 Type A raised faced4)
DN 80 PN 16 EN 1092-1 Type A raised faced4)
DN 100 PN 16 EN 1092-1 Type A raised faced4)
JD
JE
JF
KA
KB
KC
DN 50 PN 40 EN 1092-1 Type A raised faced4)
DN 80 PN 40 EN 1092-1 Type A raised faced4)
DN 100 PN 40 EN 1092-1 Type A raised faced4)
50A 10K JIS B 2220 raised faced4)
80A 10K JIS B 2220 raised faced4)
100A 10K JIS B 2220 raised faced4)
KD
KE
KF
LA
LB
LC
DN 50 PN 16 DIN EN1092-1 Type B1 raised face
DN 80 PN 16 DIN EN1092-1 Type B1 raised face
DN 100 PN 16 DIN EN1092-1 Type B1 raised face
DN 150 PN 16 DIN EN1092-1 Type B1 raised face
DN 50 PN 40 DIN EN1092-1 Type B1 raised face
DN 80 PN 40 DIN EN1092-1 Type B1 raised face
MA
MB
MC
MD
ME
MF
DN 100 PN 40 DIN EN1092-1 Type B1 raised face
DN 150 PN 40 DIN EN1092-1 Type B1 raised face
MG
MH
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
FOUNDATION Fieldbus
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20x1.5
5
1
2
3
0
1
Antenna
(Note: Please use largest horn size possible)
1½" horn
2" horn (fits 2" ASME or DN 50 nozzles)
3" horn (fits 3" ASME or DN 80 nozzles)
4" horn (fits 4" ASME or DN 100 nozzles)
1½" horn with 100 mm extension5)
2" horn with 100 mm extension
A
B
C
D
E
F
3" horn with 100 mm extension
4" horn with 100 mm extension
Hastelloy C22 (or equivalent)
2" horn (fits 2" ASME or DN 50 nozzles)
3" horn (fits 3" ASME or DN 80 nozzles)
4" horn (fits 4" ASME or DN 100 nozzles)
G
H
2" horn (fits 2" ASME or DN 50 nozzles) with
100 mm extension
3" horn (fits 3" ASME or DN 80 nozzles) with
100 mm extension
4" horn (fits 4" ASME or DN 100 nozzles) with
100 mm extension
M
Siemens FI 01 · 2012
J
K
L
N
P
5/229
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
Selection and Ordering data
Order No.
C) 7ML5431SITRANS LR250
2-wire, 25 GHz pulse radar level transmitter for con- 7 7 7 7 0 - 7 7 7 7
tinuous monitoring of liquids and slurries in storage
and process vessels including high temperature
and pressure, to a range of 20 m (66 ft). Ideal for
small vessels and low dielectric media.
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE,
A
C-TICK, KC
5
Intrinsically Safe, CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, Industry Canada FCC
B
Intrinsically Safe, IECEx/ATEX II 1 GD Ex ia IIC T4,
Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia IIC T4,
CE, R&TTE, C-TICK, KC
C
Non-incendive, CSA/FM Class I, Div. 2, Groups A,
B, C, D, FCC
D
Non-sparking, Energy Limited, ATEX II 3G Ex nA/nL
IIC T4, CE, R&TTE, C-TICK, KC
E
Increased Safety, IECEx/ATEX II 1/2 GD Ex embia
IIC T4, Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia
IIC T4, CE, R&TTE, C-TICK, KC5)
F
Flame Proof, IECEx/ATEX II 1/2 GD Ex dmbia IIC
T4, Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia IIC
T4, CE, R&TTE, C-TICK, KC5)
G
Explosion Proof CSA/FM Class I, II, III, Div. 1, Gr. A,
B, C, D, E, F, G, Industry Canada FCC5)
H
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
1)
2)
3)
4)
5)
0
1
Available with process connection options AA to HD & Antenna Versions
A to H only
Available with process connection options JA to MH & Antenna Versions
J to P only
Available For antenna versions A and E only, max. range 10 m (32.8 ft),
dk > 3
Siemens Milltronics type flange (flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5, or EN 1092-1, or
JIS B 2220 standard), see operating instructions for details
Applicable with communication option 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
5/230
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
Selection and Ordering data
Order code
Order code
Selection and Ordering data
Further designs
Accessories
Please add "-Z" to Order No. and specify Order
code(s).
Handheld programmer, Intrinsically safe, EEx ia
C) 7ML1930-1BK
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
Plug M12 with mating Connector1)2)3)
A50
Plug 7/8" with mating Connector2)3)4)
A55
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Acceptance test certificate 3.1 of EN 10204
C12
Functional Safety - SIL-2 suitable in accordance
with IEC 61508/615113) 5)
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
HART (two are required)
7ML1930-1AP
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA and
FOUNDATION Fieldbus (two are required)6)
7ML1930-1AQ
C20
FDA approved FKM o-ring for 2" G (BSPP) process
connections -28 ... 80 °C (-28 ... 176 °F)
7ML1830-3AN
Namur NE43 compliant, device preset to failsafe
< 3.6 mA5)
N07
SITRANS RD100 Remote display - see Chapter 8
Operating Instructions for HART/mA device
Order No.
English
C) 7ML1998-5JE03
C) 7ML1998-5JE33
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
C) 7ML1998-5QX82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
2)
3)
4)
5)
6)
Operating Instructions for PROFIBUS PA device
English
C) 7ML1998-5JF03
C) 7ML1998-5JF33
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
Available with enclosure option 1 only
To be used with communication options 1 and 3 only.
Connector has IP67 rating.
Available with approvals options A, B, C, D, and E only
Available with enclosure option 0 only
Applicable to communication option 2 only
For use with communication option 1 and 3 only
5
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
C) 7ML1998-5XE82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Operating Instructions for FOUNDATION
Fieldbus device
English
C) 7ML1998-5KL01
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5KL31
C) 7ML1998-5XN81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Siemens FI 01 · 2012
5/231
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
■ Characteristic curves
Ambient temperature (°C)
Maximum Flange and Process Temperatures versus Allowable Ambient Temperature
90
80
70
60
50
40
30
20
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Process Flange Surface Temperature (°C)
5
SITRANS LR250 Ambient/Process Flange Surface Temperature Curve
5/232
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
■ Dimensional drawings
Flanged
SITRANS LR250
enclosure/
electronics
½" NPT cable entry
(or alternatively,
M20 cable gland)
nameplate
187 (7.4)
50
(2.0)
threaded cover
retaining collar
flange
sensor reference
point
horn
process device
tag
horn
O.D.
5
Threaded
185 (7.3)
109 (4.3)
154 (6.1)
optional
100 (3.93)
horn
extension
A
28 (1.1)
D
C
B
281 (11.1)
retaining
collar
sensor reference
point
process
device tag
horn
horn
O.D.
Nominal Horn
Size
121 (4.8)
158 (6.2)
enclosure/
electronics
horn
O.D.
Horn O.D.
Horn Height
Beam Angle
Measurement
Range
40 (1.5)
39.8 (1.57)
A
135 (5.3)
19 degrees
10 m (32.8 ft)
50 (2)
47.8 (1.88)
B
166 (6.55)
15 degrees
20 m (65.6 ft)
80 (3)
74.8 (2.94)
C
199 (7.85)
10 degrees
20 m (65.6 ft)
100 (4)
94.8 (3.73)
D
254 (10)
8 degrees
20 m (65.6 ft)
SITRANS LR250, dimensions in mm (inch)
Siemens FI 01 · 2012
5/233
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
5
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Instrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 to 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
5/234
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 Specials
SITRANS LR250 Specials
SITRANS LR250 Specials
Order No.
Order No.
SITRANS LR250 horn version enclosure with board C) A5E02956320
stack, M20 cable inlet, approval option E,
with HART communication start-up at < 3.6 mA,
no process connection
SITRANS LR250 horn version enclosures
(PROFIBUS PA models)
LR250 horn version enclosure with board stack,
C) A5E01156836
NPT cable inlet, approval option A, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156838
M20 cable inlet, approval option A, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156839
NPT cable inlet, approval option B, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156841
M20 cable inlet, approval option B, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156843
NPT cable inlet, approval option C, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156844
M20 cable inlet, approval option C, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156846
M20 cable inlet, approval option C, with PROFIBUS
PA communication, no process connection
LR250 horn version enclosure with board stack,
C) A5E01156848
M20 cable inlet, approval option D, with PROFIBUS
PA communication, no process connection
SITRANS LR250 horn version enclosure with board C) A5E02956322
stack, M20 cable inlet, approval option F,
with HART communication start-up at < 3.6 mA,
no process connection
SITRANS LR250 horn version enclosure with board C) A5E02956323
stack, M20 cable inlet, approval option G,
with HART communication start-up at < 3.6 mA,
no process connection
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A, with HART
communication start-up at < 3.6 mA, no process
connection
C) A5E03441096
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option B, with HART
communication start-up at < 3.6 mA, no process
connection
C) A5E03441097
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option D, with HART
communication start-up at < 3.6 mA, no process
connection
C) A5E03441098
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option H, with HART
communication start-up at < 3.6 mA, no process
connection
C) A5E03441099
5
SITRANS LR250 horn antenna and
extension kits
SITRANS LR250 horn version enclosures
(FOUNDATION Fieldbus models)
38 mm (1.5 inch) horn antenna kit,
1.5 inch Process Connections only
C) A5E01151539
100 mm (4 inch) horn antenna extension kit,
1.5 inch Process Connections only
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
C) A5E02654608
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
C) A5E02653792
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
C) A5E02653793
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
C) A5E02654606
A5E01151553
50 mm (2 inch) stainless steel 316L horn antenna C) A5E01151569
kit
75 mm (3 inch) stainless steel 316L horn antenna C) A5E01151571
kit
100 mm (4 inch) stainless steel 316L horn antenna C) A5E01151573
kit
SITRANS LR250 horn version enclosures
(< 3.6 mA start-up HART)
100 mm (4 inch) horn antenna extension kit,
50 mm (2 inch), 75 mm (3 inch) and 100 mm
(4 inch) process connection
C) A5E01151577
50 mm (2 inch) horn antenna kit, Hastelloy C-22
J) A5E01151584
75 mm (3 inch) horn antenna kit, Hastelloy C-22
J) A5E01151585
100 mm (4 inch) horn antenna kit, Hastelloy C-22
J) A5E01151587
5 Dupont 1Gr Polyback, PTFE grease kit
C) A5E01151626
LR250 lid with O-ring
A5E02465410
C) Subject to export regulations AL: N, ECCN: EAR99.
J) Subject to export regulations AL: 9I999, ECCN: EAR99.
Please contact [email protected] for special requests.
SITRANS LR250 horn version enclosure with board C) A5E02956317
stack, M20 cable inlet, approval option A,
with HART communication start-up at < 3.6 mA,
no process connection
SITRANS LR250 horn version enclosure with board C) A5E02956319
stack, M20 cable inlet, approval option C,
with HART communication start-up at < 3.6 mA,
no process connection
Siemens FI 01 · 2012
5/235
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Overview
5
■ Benefits
SITRANS LR250 with threaded PVDF antenna is a 2-wire,
25 GHz pulse radar level transmitter for continuous monitoring of
liquids and slurries in storage and process vessels including
corrosives or aggresive materials, to a range of 10 m (32.8 ft).
• Fully insulated PVDF antenna design for use in chemical and
sanitary environments where aggressive and corrosive materials are used
• Cost effective replacement for transmitters made of exotic
materials
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency and 2" (50 mm) process
connection/antenna allow for easy mounting in nozzles
• Insensitive to mounting location and obstructions, and less
sensitive to nozzle interference
• Short blanking distance for improved minimum measuring
range to 50 mm (2 inch) from the end of the horn
• Communication using HART or PROFIBUS PA, or
FOUNDATION Fieldbus
• Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed
obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or over a network using SIMATIC PDM,
Emerson AMS, or Field Device Tools, such as PACTware or
Fieldcare via SITRANS DTM.
• Suitable for use in Safety Related Systems in accordance with
IEC 61508/61511 (SIL-2)
■ Application
SITRANS LR250 includes a graphical local user interface (LUI)
that improves setup and operation by including an intuitive
Quick Start Wizard, and echo profile displays for diagnostic
support. Startup is easy using the Quick Start wizard with a few
parameters required for basic operation.
The 25 GHz frequency creates a narrow, focused beam allowing
for smaller antenna options and decreasing sensitivity to
obstructions.
SITRANS LR250’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR250 measures superbly in small vessels and in
tanks/vessels up to 10 m (32 ft) on materials with dk > 3.
• Key Applications: liquid bulk storage tanks, process vessels
with agitators, vaporous liquids, temperatures to 80 °C
(176 °F), corrosive and aggressive materials, media with
dielectric (dk) ≥ 3 (application dependent)
5/236
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Configuration
Installation
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• The peak energy density is
directly in front of and in line
with the antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
Mounting unit on bypass
Orient front or back of
device toward vent.
Mounting unit on
stilling well
5
Orient front or back of device
toward stillpipe slots.
Mounting on a nozzle
min. 10 (0.4)
Mounting unit on vessel
19°
SITRANS LR250 PVDF antenna installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/237
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Radar level measurement
Frequency
K-band (25.0 GHz)
Minimum measuring range
50 mm (2 inch) from end of horn
Maximum measuring range
10 m (32.8 ft)
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 Ω
PROFIBUS PA
• 15 mA
• per IEC 61158-2
FOUNDATION Fieldbus
• 20.0 mA
• per IEC 61158-2
Output
5
HART
• Analog output
• Accuracy
• Fail-safe
Version 5.1
4 ... 20 mA
± 0.02 mA
• Programmable as high low or
hold (loss of echo)
• NE 43 programmable
PROFIBUS PA
Profile 3.1
• Function blocks
2 Analog Input (AI)
FOUNDATION Fieldbus
• Functionality
• Version
• Function blocks
H1
Basic or LAS
ITK 5.2.0
2 Analog Input (AI)
Performance (according to
reference conditions IEC60770-1)
Maximum measured error
Influence of ambient temperature
• > 500 mm from sensor reference
point: 5 mm (0.2 inch)
• < 500 mm from sensor reference
point: 25 mm (1 inch)
Certificates and approvals
General
CSAUS/C, CE, FM, NE 21, C-TICK,
KC
Radio
FCC, Industry Canada and
Europe ETSI EN 302-372, C-TICK
Hazardous
• Intrinsically Safe (Europe)
• Intrinsically Safe (China)
• Non-sparking/Energy Limited
(Europe)
• Non-sparking/Energy Limited
(China)
• Intrinsically Safe (Canada/USA)
• Non-incendive (Canada/USA)
< 0.003 %/K
• Intrinsically Safe (International)
Indoor/outdoor
• Intrinsically Safe (Brazil)
• Flame Proof
(International/Europe)
Rated operating conditions
Installation conditions
Location
Ambient conditions (enclosure)
• Explosion Proof (Brazil)
Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
Installation category
I
Pollution degree
4
• Increased Safety
(International/Europe)
Dielectric constant εr
≥ 3 (1.6 in stillpipe)
• Increased Safety (Brazil)
• Explosion Proof (Canada/USA)
Process temperature
-40 ... +80 °C (-40 ... +176 °F) at
process connection
Process pressure
Up to 5 bar g (72 psi g) temperature dependent.
See Pressure/Temperature curves
for more information
Medium conditions
• Increased Safety/Flameproof
(China)
Aluminium, polyester powdercoated
2 x M20x1.5 or 2 x ½" NPT
• Cable inlet
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
Weight
approximately 3.3 kg (7.27 lb)
Display (local)
Graphic local user interface
including quick start wizard and
echo profile display
Antenna
• Material
• Dimensions (nominal horn sizes)
PVDF (Polyvinylidene fluoride)
2" (48 mm)
Process connections
Process connection
5/238
Siemens FI 01 · 2012
NEPSI Ex nA/nL IIC T4
CSA/FM Class I, Div. 1, Groups A,
B, C, D; Class II, Div. 1, Groups
E, F, G; Class III T4
CSA/FM Class I, Div. 2, Groups A,
B, C, D T5
IECEx Ex ia IIC T4, Ex tD A20
IP67 T90°C
INMETRO Br-Ex ia IIC T4
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex dmbia IIC T4 Ga/Gb, Ex tD
A20 IP67 T90°C
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex embia IIC T4 Ga/Gb, Ex tD
A20 IP67 T90°C
IECEx/ATEX II 1/2 GD, 1D, 2D,
Ex embia IIC T4 Ga/Gb, Ex tD
A20 IP67 T90°C
INMETRO Br-Ex embia IIC T4
CSA/FM Class I, Div. 1, Groups A,
B, C, D; Class II, Div. 1, Groups
E, F, G; Class III T4
Ex dmbia IIC T4/ Ex embia IIC T4/
DIP A20 TA, T90°C IP67
Marine
• Lloyd’s Register of Shipping
• ABS Type Approval
• Bureau Veritas
Functional safety
SIL-2 suitable in accordance with
IEC 61508/61511
Design
Enclosure
• Material
ATEX II 1G EEx ia IIC T4
ATEX II 1D EEx tD A20 IP67
T90°C
NEPSI Ex ia IIC T4/DIP A20 TA
T90°C IP67
ATEX II 3G EEx nA/nL IIC T4 Gc
Programming
Intrinsically Safe Siemens handheld
programmer
• Approvals for handheld
programmer
Infrared receiver
Handheld communicator
HART communicator 375/475
PC
• SIMATIC PDM
• Emerson AMS
• SITRANS DTM (for connection
into FDT, such as PACTware or
Fieldcare)
Display (local)
Graphic local user interface
including quick start wizard and
echo profile displays
2" NPT [(Taper), ASME B1.20.1]
2" [(BSPT), EN 10226]
2" [(BSPP), EN ISO 228-1]
IS model:
ATEX II 1 GD Ex ia IIC T4 Ga
Ex ia D 20 T = 135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, III, Div. 1.,
Groups A, B, C, D, E, F, G, T6
Ta = 50 °C
IECEx SIR 09.0073
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
Selection and Ordering data
C)
SITRANS LR250 threaded PVDF antenna
2-wire, 25 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
storage and process vessels including corrosives
or aggresive materials, to a range of 10 m (32.8 ft).
Process Connection and Antenna Material
Threaded PVDF antenna
Process Connection Type
Threaded connections PVDF
2" NPT (ASME B1.20.1) (tapered thread)
R 2" [(BSPT), EN 10226-1] (tapered thread)
G 2" [(BSPP), EN ISO 228-1] (parallel thread)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, startup at < 3.6 mA
FOUNDATION Fieldbus
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20x1.5
Antenna
2" (50 mm) threaded PVDF antenna
Approvals
General Purpose, CE, CSA, FM, FCC, R&TTE,
C-TICK, KC
Intrinsically Safe, CSA/FM Class I, II, III, Div. 1,
Groups A, B, C, D, E, F, G, Industry Canada FCC
Order No.
7ML5431-
Selection and Ordering data
7 7 7 7 0 - 777 7
Please add "-Z" to Order No. and specify Order
code(s).
4
PA
PB
PC
1
2
3
A50
Plug 7/8" with mating Connector2)3)4)
A55
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Functional Safety - SIL2 suitable in accordance
with IEC 61508/615115) 6)
C20
Namur NE43 compliant, device preset to failsafe
< 3.6 mA5)
N07
English
A
C) 7ML1998-5QX82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
B
Non-sparking, Energy Limited, ATEX II 3G Ex nA/nL
IIC T4, CE, R&TTE, C-TICK, KC
E
Increased Safety, IECEx/ATEX II 1/2 GD Ex embia
IIC T4, Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia
IIC T4, CE, R&TTE, C-TICK, KC1)
Flame Proof, IECEx/ATEX II 1/2 GD Ex dmbia IIC
T4, Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia IIC
T4, CE, R&TTE, C-TICK, KC1)
Explosion Proof CSA/FM Class I, II, III, Div. 1, Gr. A,
B, C, D, E, F, G, Industry Canada FCC1)
Pressure rating
Rating per Pressure/Temperature curves in manual
F
Order No.
C) 7ML1998-5JE03
C) 7ML1998-5JE33
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
R
C
Applicable to Communication option 2 only
C) Subject to export regulations AL: N, ECCN: EAR99.
Plug M12 with mating Connector1)2)3)
Operating Instructions for HART/mA device
0
1
Intrinsically Safe, IECEx/ATEX II 1 GD Ex ia IIC T4,
Ex tD A20 IP67 T90°C, INMETRO Br-Ex ia IIC T4,
CE, R&TTE, C-TICK, KC
Non-incendive, CSA/FM Class I, Div. 2, Groups A,
B, C, D, FCC
1)
Order code
Further designs
Operating Instructions for PROFIBUS PA device
English
D
C) 7ML1998-5JF03
C) 7ML1998-5JF33
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
C) 7ML1998-5XE82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
G
Operating Instructions for
FOUNDATION Fieldbus device
English
H
0
C) 7ML1998-5KL01
C) 7ML1998-5KL31
German
Note: The Operating Instructions should be ordered as a separate line item on the order.
C) 7ML1998-5XN81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Siemens FI 01 · 2012
5/239
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
Order code
Selection and Ordering data
Accessories
Handheld programmer, Intrinsically safe, EEx ia
C) 7ML1930-1BK
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA and
FOUNDATION Fieldbus7)
7ML1930-1AQ
FDA approved FKM o-ring for 2" G (BSPP) process
connections -28 ... +80 °C (-28 ... +176 °F)
7ML1830-3AN
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
2)
3)
4)
5)
6)
7)
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99R.
K) Subject to export regulations AL: N, ECCN: 5A991X.
■ Characteristic curves
Pressure/Temperature Curve
Pressure (bar, gauge)
5
Available with Enclosure option 1 only
To be used with Communication options 1 and 3 only.
Connector has IP67 rating.
Available with Approvals option A, B, or C only
Available with Enclosure option 0 only
Applicable to Communication option 2 only
Available with Approval options A to E only
For use with Communication option 1 and 3 only
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
-0.5
-1
-60
-40
-20
0
20
40
60
80
100
Temperature (°C)
SITRANS LR250 PVDF antenna pressure/temperature curve
5/240
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF antenna
■ Dimensional drawings
50
(2.0)
1/2" NPT cable entry (or
alternatively, M20 cable gland)
threaded cover
167
(6.6)
154
(6.1)
90
(3.5)
enclosure/
electronics
184
(7.24)
5
146
(5.74)
process
connection tag
sensor reference
point
121
(4.76)
2" thread
threaded PVDF
antenna
49.5
(1.94)
antenna O.D.
SITRANS LR250 PVDF antenna, dimensions in mm (inch)
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand Programmer
Shield for HART,
PROFIBUS PA , and
FOUNDATION Fieldbus
Instrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 to 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR250 connections
Siemens FI 01 · 2012
5/241
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR250 threaded PVDF Specials
SITRANS LR250 threaded PVDF Specials
SITRANS LR250 threaded PVDF Specials
Order No.
SITRANS LR250 threaded PVDF
antenna version enclosures
(PROFIBUS PA models)
5
Order No.
SITRANS LR250 threaded PVDF
antenna version enclosures
(< 3.6 mA start-up HART models)
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option A, with PROFIBUS PA communication, no process connection
A5E03588171
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option A,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03569747
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option A, with PROFIBUS PA communication, no process connection
A5E03588253
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03586807
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option B, with PROFIBUS PA communication, no process connection
A5E03588512
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option B,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03586854
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option C, with PROFIBUS PA communication, no process connection
A5E03589260
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03586887
LR250 threaded PVDF antenna version
enclosure with board stack, NPT cable inlet,
approval option D, with PROFIBUS PA communication, no process connection
A5E03589262
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option D,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03586961
LR250 threaded PVDF antenna version
enclosure with board stack, M20 cable inlet,
approval option E, with PROFIBUS PA communication, no process connection
A5E03589264
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option E,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03587012
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option F,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03587132
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option G,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03587223
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option H,
with HART communication start-up at < 3.6 mA,
no process connection
A5E03588125
SITRANS LR250 threaded PVDF
antenna version enclosures
(FOUNDATION Fieldbus models)
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589266
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option A,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589275
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option B,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589277
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option C,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589280
LR250 horn version enclosure with board stack,
NPT cable inlet, approval option D,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589281
LR250 horn version enclosure with board stack,
M20 cable inlet, approval option E,
with FOUNDATION Fieldbus communication,
no process connection
A5E03589283
5/242
Siemens FI 01 · 2012
SITRANS LR250 threaded PVDF
antenna kits
Antenna kit 2" NPT threaded PVDF
A5E03528941
Antenna kit 2" R (BSPT) threaded PVDF
A5E03528943
Antenna kit 2" G (BSPP) threaded PVDF
A5E03528947
Kit of hardware parts for LR250 threaded PVDF
antenna
A5E03528948
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260
■ Overview
■ Configuration
Min. clearance:
10 (0.4)
Mounting on
a nozzle
min. 1 000 (39)
Installation
SITRANS LR260 is a 2-wire 25 GHz pulse radar level transmitter
for continuous monitoring of solids in storage vessels including
extreme levels of dust and high temperatures, to a range of
30 m (98.4 ft).
■ Benefits
5
emission
cone
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• 25 GHz high frequency allows for small horn antennas
mounted easily in nozzles
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed
obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM
beam angle:
2" horn = 15°
3" horn = 10°
4" horn = 8°
■ Application
SITRANS LR260 includes a graphical local user interface (LUI)
that improves setup and operation using an intuitive Quick Start
Wizard, and echo profile displays for diagnostic support. Startup
is easy using the Quick Start wizard with a few parameters required for basic operation.
Positioning with
Easy Aimer
SITRANS LR260’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid.
SITRANS LR260 measures virtually any solids material to a
range of 30 m (98.4 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, flour, coal, solids bulk storage vessels, and other applications.
SITRANS LR260 installation, dimensions in mm (inch)
Siemens FI 01 · 2012
5/243
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260
■ Technical specifications
Mode of operation
Design
Measuring principle
Pulse radar level measurement
Enclosure
Frequency
K-band (25.0 GHz)
• Construction
Minimum detectable distance
0.05 m (2 inch) from end of horn
Aluminium, polyester powdercoated
Maximum measuring range1)
• 2" horn: 10 m (32.8 ft)
• 3" horn: 20 m (65.6 ft)
• 4" horn: 30 m (98.4 ft)
• Conduit entry
2 x M20x1.5 or 2 x ½" NPT
Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP67, IP68
Weight
< 8.14 kg (17.9 lb) including
4" flange and standard Easy
Aimer with 4" horn antenna
Display (local)
Graphic LCD, with bar graph
representing level
Output - HART
Power
• 4 ... 20 mA (±0.02 mA accuracy)
• Nominal 24 V DC (max. 30 V DC)
Fail signal
3.6 mA ... 23 mA; or last value
Load
230 ... 600 Ω, 230 ... 500 Ω when
connecting a coupling module
Max. line length
Output - PROFIBUS PA
5
Multi-wire: ≤ 1500 m (4921 ft)
Protocol HART, Version 5.1
• Per IEC 61158-2
• 15.0 mA
• Profile version 3.01, Class B
304 stainless steel
• Dimensions (nominal horn sizes)
2" horn: 1.93" (49.0 mm) diameter
3" horn: 2.93" (74.5 mm) diameter
4" horn: 3.84" (97.5 mm) diameter
Process connections
• Universal flanges2)
Performance (according to
reference conditions IEC60770-1)
Maximum measured error (including
hysteresis and non-repeatability)
Flange and horn
• Material
• 25 mm (1 inch) from minimum
detectable distance to
300 mm (11.8 inch)
• Remainder of range = 10 mm
(0.39 inch) or 0.1% of span
(whichever is greater)
Rated operating conditions
Certificates and approvals
General
CSAUS/C, CE, FM
Radio
Europe (R&TTE), FCC,
Industry Canada, C-TICK
Hazardous
CSA/FM Class II, Div. 1,
Groups E, F, G, Class III
Installation conditions
• Location
2"/50 mm, 3"/80 mm, 4"/100 mm,
6"/150 mm
ATEX II 1D, 1/2D, 2D Ex tD A20
IP67, IP68 T100 ºC
Indoor/outdoor
Programming
Ambient conditions (enclosure)
• Ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• Installation category
I
• Pollution degree
4
Intrinsically Safe Siemens handheld
programmer
Infrared receiver
• Approvals for handheld
programmer
IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T = 135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1.
Gr. A-G, T6 Ta = 50 °C
Medium conditions
Dielectric constant εr
εr > 1.6, antenna and application
dependent
Process temperature
-40 ... +200 °C (-40 ... +392 °F)
Handheld communicator
HART communicator 375
Process pressure
• 0.5 bar g (7.25 psi g) maximum
• 3 bar g (43.5 psi g) optional with
80 °C (176 °F) temperature max.
PC
SIMATIC PDM
Display (local)
Graphic local user interface
including quick start wizard and
echo profile displays
1)
2)
5/244
Siemens FI 01 · 2012
From sensor reference point
Universal flange mates with EN 1092-1 (PN 16)/ASME B16.5 (150 lb)/
JIS 2220 (10K) bolt hole pattern
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260
Selection and Ordering data
Order No.
C) 7ML5427SITRANS LR260
2-wire, 25 GHz pulse radar level transmitter for
0 7 7 7 0 - 77 7 7
continuous monitoring of solids to a range of 30 m
(98.4 ft).
Order handheld programmer separately!
Process connection
Universal flat faced flange fits ANSI/DIN/JIS flanges, Easy Aimer with integral (Easy Aimer ball)
2"/50 mm
A
3"/80 mm
B
4"/100 mm
6"/150 mm
C
D
Antenna
2" Horn antenna, fits 50 mm or 2" nozzles1)
A
2" Horn antenna with 100 mm extension1)
2" Horn antenna with 200 mm extension1)
B
C
2" Horn antenna with 500 mm extension1)2)3)
2" Horn antenna with 1000 mm extension1)2)3)
D
E
3" Horn antenna, fits 80 mm or 3" nozzles4)
3" Horn antenna with 100 mm extension4)
F
G
3" Horn antenna with 200 mm extension4)
3" Horn antenna with 500 mm extension2)3)4)
H
J
3" Horn antenna with 1000 mm extension2)3)4)
4" Horn antenna, fits 100 mm or 4" nozzles
K
L
4" Horn antenna with 100 mm extension
4" Horn antenna with 200 mm extension
M
N
extension2)3)
4" Horn antenna with 500 mm
4" Horn antenna with 1000 mm extension2)3)
Purge (self cleaning) connection
No purge connection
Purge connection
Output/communication
4 ... 20 mA, HART
PROFIBUS PA
Cable inlet
2 x M20x1.5
2 x ½" NPT
Note: Polymeric cable glands will be provided with
M20 devices.
Approvals
General purpose, CSAUS/C, FM, Industry Canada,
FCC, CE, R&TTE, C-TICK
CSA/FM Class II, Div. I, Groups E, F, G, Class III,
Industry Canada, FCC, C-TICK
ATEX II 1D, 1/2D, 2D T100 ºC, CE, R&TTE, C-TICK
Pressure rating
3 bar g (43.5 psi g) pressure maximum and
80 °C (176 °F)
0.5 bar g (7.25 psi g) maximum
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
Inspection Certificate Type 3.1 per EN 10204
C11
Operating Instructions for HART/mA device
Order No.
C12
C) 7ML1998-5KE01
English
German
C) 7ML1998-5KE11
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual
C) 7ML1998-5KE31
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
C) 7ML1998-5KF01
English
German
C) 7ML1998-5KF31
Note: The Operating Instructions should be
ordered as a separate line item on the order.
Multi-language Quick Start manual
C) 7ML1998-5XJ81
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART1)
7ML1930-1AP
7ML1930-1AQ
0
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA1)
1
Handheld programmer, Infrared, Intrinsically Safe C) 7ML1930-1BK
P
Q
0
1
Dust cap, PTFE, for 2"/50 mm horn
7ML1930-1DE
Dust cap, PTFE, for 3"/75 mm horn
7ML1930-1BL
Dust cap, PTFE, for 4"/100 mm horn
A
B
7ML1930-1BM
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
SITRANS RD100 Remote display - see Chapter 8
A
SITRANS RD200 Remote display - see Chapter 8
B
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C
1)
0
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
1
K) Subject to export regulations AL: N, ECCN: 5A991X.
1)
Maximum measurement range 10 m (32.8 ft)
2)
Available with purge connection option 0 only
3) Available with pressure option 1 only
4)
Maximum measurement range 20 m (65.6 ft)
:
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/245
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260
■ Characteristic curves
Ambient temperature (°C)
Maximum Flange and Process Temperatures versus Allowable Ambient Temperature
90
80
70
60
50
40
30
20
10
0
0
50
100
150
200
250
Process Flange SurfaceTemperature (°C)
SITRANS LR260 Ambient/Process Flange Surface Temperature Curve
■ Dimensional drawings
enclosure/electronics
268 (10.6)
nameplate
optional purge connection
with factory-installed
1/8” NPT plug
universal slotted flange
process
device tag
sensor
reference
point
optional extension
100/200/500/1000
(3.93/7.87/19.68/39.37)
horn
optional PTFE dust cap
clamp screw
49 (1.9)
74.5 (2.9)
97.5 (3.8)
SITRANS LR260, dimensions in mm (inch)
5/246
Siemens FI 01 · 2012
2" horn: 163 (6.4)
3" horn: 228 (9.0)
4" horn: 285 (11.2)
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
gland
Hand Programmer
Shield for HART and
PROFIBUS PA
Instrinsically Safe
versions only.
Part number:
7ML1930-1BK
Notes:
5
1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable
safety requirements of IEC 61010-1.
2. All field wiring must have insulation suitable for rated input voltages.
3. Use shielded twisted pair cable (14 to 22 AWG) for HART version.
4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR260 connections
Siemens FI 01 · 2012
5/247
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
■ Overview
■ Application
It provides excellent results on low dielectric media.
SITRANS LR400 is available for standard applications and for
applications that require explosion proof protection.
SITRANS LR400 features robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temperature conditions within the vessel.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming.
The characteristics of 24 GHz and high signal-to-noise ratio contribute to exceptional signal reflection, regardless of the dielectric value of the medium.
• Key applications: long-range liquid or slurry applications, high
temperature or high pressure, low dielectric media, such as
LPG (liquid, petroleum, gas)
■ Benefits
•
•
•
•
•
•
•
Easy installation and commissioning, low maintenance
Self-calibration with internal reference
Built-in diagnostics
Auto False-Echo Suppression and advanced echo processing
24 GHz and high signal-to-noise ratio
Communication using HART or PROFIBUS PA
Programming using infrared Intrinsically Safe handheld programmer or with SIMATIC PDM or HART handheld device
■ Configuration
Beam angle
13°
short horn antenna
9°
long horn antenna
Installation in Mounting Nozzle
Mounting unit on vessel
10
(0.39)
5
The SITRANS LR400 is a 4-wire, 24 GHz FMCW radar level transmitter for continuous monitoring of liquids and slurries in storage
and process vessels including high temperature and high pressure, to a range of 50 m (164 ft); ideal for low dielectric media.
Note: For best signal, always use largest horn size possible.
SITRANS LR400 installation, dimensions in mm (inch)
5/248
Siemens FI 01 · 2012
Conical
Flat
Parabolic
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
■ Technical specifications
Mode of operation
Programming
Measuring principle
FMCW radar level measurement
Frequency
24 ... 25 GHz FMCW
Measuring range
0.35 ... 50 m (1.15 ... 164 ft)
Intrinsically Safe Siemens handheld
programmer (ordered separately)
Infrared receiver
• Approvals for handheld programmer
IS model with ATEX EEx ia IIC T4,
CSA/FM Class I, Div. 1, Groups A,
B, C, D T6 at max. ambient
temperature of 40 °C (104 °F)
Handheld communicator
HART communicator 375
PC
SIMATIC PDM
Display (local)
Alphanumeric LCD for readout
and entry
Power supply
100 ... 230 V AC ± 15%
(50/60 Hz), 6 W (12 VA)
or
24 V DC +25/-20%, 6 W (optional)
Output
Analog output (HART)
• Signal range
Optically isolated 4 ... 20 mA
• Load
Max. 600 Ω (330 Ω for [ia] versions, Area classification options
G, L, P, S)
• Relay
NC or NO function, max. DC 50 V,
max. 200 mA, rating 5 W
Communication
HART, optional PROFIBUS PA
PROFIBUS PA protocol
Layer 1 and 2, Class A, Profile 3.0
Performance
(Reference conditions)
Dead band
0 ... 350 mm from bottom edge
of flange
Error in measurement at
25 °C (77 °F)
≤ 5 mm from 2 ... 10 m
≤ 15 mm from 10 ... 50 m
• Repeatability
≤ 1 mm
• Fail-safe
mA signal programmable as high,
low or hold (LOE)
Certificates and approvals
Safety
CSAUS/C, CE, FM, C-TICK
Shipping
• Lloyd's Register of Shipping
• ABS
Radio
Europe (R&TTE, CETECOM),
Industry Canada, FCC, C-TICK
Hazardous areas
ATEX II 1/2 G EEx dem [ia] IIC T6
ATEX II 1/2 G EEx dem IIC T6
CSA/FM
Class I, Div. 1, Groups B, C, D;
Class II, Div. 1, Groups E, F, G;
Class III T6, INMETRO
Optional equipment
Purging (self-cleaning) system
PTFE dust cover
Rated operating conditions
Amb. temperature for enclosure
-40 ... +65 °C (-40 ... +149 °F)
Location
Indoor/outdoor
Installation category
II
Pollution degree
4
Medium conditions
Dielectric constant
εr>1.4
Process temperature range
• Standard
-40 ... +200 °C (-40 ... +392 °F)
-20 ... +200 °C (-4 ... +392 °F) for
SITRANS LR400 with ATEX rating
• With optional temperature
extension
-40 ... +250 °C (-40 ... +482 °F)
Vessel Pressure
Up to 40 bar g
(process connection dependent)
Design
Weight
Approx. 12.2 kg (26.8 lb) with
3" 150 psi flange
Materials
• Enclosure
Die-cast aluminum, painted
• Degree of protection
IP67/Type 4X/NEMA 4X,
Type 6/NEMA 6
• Cable inlet
2x M20x1.5 or ½" NPT
• Process connections
• Flat faced flanges
316L stainless steel, 80, 100,
150 mm, bolt holes matching
EN 1092-1 and JIS B 2220
• Raised face flanges
316L stainless steel, 3", 4", 6",
bolt holes matching ASME B 16.5
Siemens FI 01 · 2012
5/249
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
Selection and Ordering data
5
Order No.
Order No.
Selection and Ordering data
L) 7ML5421SITRANS LR400
4-wire, 24 GHz FMCW radar level transmitter for
77 7 77 - 777 7
continuous monitoring of liquids and slurries in storage and process vessels including high temperature and high pressure, to a range of
50 m (164 ft); ideal for low dielectric media.
Order handheld programmer separately!
L) 7ML5421SITRANS LR400
4-wire, 24 GHz FMCW radar level transmitter for
7 7 7 77 - 77 7 7
continuous monitoring of liquids and slurries in storage and process vessels including high temperature and high pressure, to a range of
50 m (164 ft); ideal for low dielectric media.
Order handheld programmer separately!
Process temperature range
-40 °C ... +200 °C (-40 ... +392 °F), standard
-40 °C ... +250 °C (-40 ... +482 °F), high temperature extension
FM Class I, Div. 1, Groups B, C, D; Class II/III,
Div. 1, Groups E, F, G; FCC2)
CSA Class I, Div. 1, Groups B, C, D; Class II/III,
Div. 1, Groups E, F, G; FCC2)
0
1
Process connection
Universal flange 3"/80 mm1)
Universal flange 4"/100 mm1)
Universal flange 6"/150 mm1)
A
B
D
DN 80, PN 16, Type A, flat faced
DN 80, PN 40, Type B1, raised face
DN 100, PN 16, Type A, flat faced
S
C
T
DN 100, PN 40, Type B1, raised face
DN 150, PN 16, Type A, flat faced
3" ASME, 150 lb, raised face
G
U
E
3" ASME, 300 lb, raised face
4" ASME, 150 lb, raised face
4" ASME, 300 lb, raised face
F
J
K
6" ASME, 150 lb, raised face
JIS, DN 80 10K
JIS, DN 100 10K
N
Q
R
JIS, DN 150 10K
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1, or JIS B 2220 standard.)
V
Antenna
Horn antenna, long 93 mm (3.66 inch) diam. for
100 mm (4 inch) nozzles
Horn antenna, short 74 mm (2.91 inch) diam. for
80 mm (3 inch) nozzles
Antenna purging system
None
Purging system
Note: Available with process connections A, B or
D, and for area classifications A or B only
Process seal/gasket
PTFE for -40 ... +250 °C (-40 ... +482 °F)
flange temperatures
FKM for -20 ... +200 °C (-4 ... +392 °F)
flange temperatures2)
Output/communication
4 ... 20 mA, HART
PROFIBUS PA
U
Available with antenna purging system option 1 only, universal,
0.5 bar g (7.25 psi g) maximum
Available with process temperature range option 0 only
3) Available only with power supply option E or F
2)
D) Subject to export regulations AL: N, ECCN: EAR99H.
L) Subject to export regulations AL: N, ECCN: 3A991X.
D
K
0
1
1
3
0
1
24 V DC
• 2 x M20x1.5
• 2 x ½" NPT
E
F
B
E
F
ATEX II 2G EEx dem [ia] IIC T6; CE, R&TTE3)
ATEX II 1/2 GD EEx d IIC T6; CE, R&TTE2)
ATEX II 1/2 GD EEx dem IIC T6; CE, R&TTE2)
G
J
K
ATEX II 1/2 GD EEx dem [ia] IIC T6; CE, R&TTE2)3)
L
Siemens FI 01 · 2012
D)
1)
B
C
5/250
T
Local operation
Local Display Only. Handheld programmer not
included (Order programmer separately.)
Power supply/cable inlet
100 ... 230 V AC
• 2 x M20x1.5
• 2 x ½" NPT
Area classification
General Purpose, CSAUS/C, Industry Canada, FCC,
CE and R&TTE
ATEX II 2G EEx d IIC T6; CE, R&TTE
ATEX II 2G EEx dem IIC T6; CE, R&TTE
D)
2
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Order No.
Operating Instructions
English
C) 7ML1998-5FH06
German
C) 7ML1998-5FH36
French
C) 7ML1998-5FH16
Spanish
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-5FH22
C) 7ML1998-5QN83
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Order No.
Handheld programmer Intrinsically Safe, EEx ia
7ML5830-2AJ
Long horn dust cover, PTFE
7ML1930-1AH
Short horn dust cover, PTFE
5
7ML1930-1AJ
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART1)
7ML1930-1AP
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA1)
7ML1930-1AQ
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/251
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
■ Characteristic curves
Flange 22482 or 22487,
FF Standard Process Seal
Flange 22482 or 22487,
FF Process Seal for Hazardous Locations
30.0
45.0
40.0
Pressure (bar, gauge)
Pressure (bar, gauge)
25.0
20.0
15.0
10.0
5.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
-100
-50
0
50
100
150
Temperature (°C)
200
250
0.0
-100
300
200
150 mm, PN40
80 mm, 100 mm, 150 mm, PN16 or 10K
80 mm, 100 mm, 150 mm, PN16 or 10K
250
300
Flange 22483 or 22488,
RF Process Seal for Hazardous Locations
ATEX II 1/2 G Approval options
30.0
60.0
25.0
50.0
Pressure (bar, gauge)
Pressure (bar, gauge)
50
100
150
Temperature (°C)
150 mm, PN40
Flange 22483 or 22488,
RF Standard Process Seal
ATEX II 2 G Approval options
20.0
15.0
10.0
40.0
30.0
20.0
10.0
5.0
0.0
-100
-50
0
50
100
150
Temperature (°C)
200
250
300
0.0
-100
-50
0
50
100
150
Temperature (°C)
3", 4", 300#
3", 4", 300#
6", 300#
6", 300#
3", 4", 6", 150#
3", 4", 6", 150#
SITRANS LR400 Process Pressure/Temperature derating curves
5/252
0
80 mm, 100 mm, PN40
80 mm, 100 mm, PN40
5
-50
Siemens FI 01 · 2012
200
250
300
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
■ Dimensional drawings
SITRANS LR400 (7ML5421)
SITRANS LR400
SITRANS LR400
(with temperature
extension)
Ambient Temperature (°C)
Maximum Flange and Process Temperature
Versus Allowable Ambient Temperature
204
(8.0)
earth
terminal
intermediate
flange
threaded
ring
horn
antenna
191
(7.5)
process
flange
20
10
0
25
50
75 100 125 150 175 200 225 250 275
Process Temperature (°C)
standard
optional temperature extension
191
(7.5)
LR400
238 (9.4)
SITRANS
257 (10.1)
electronics
cover
40
30
0
384 (15.1)
204
(8.0)
50
74
(2.9)
74
(2.9)
93 (3.7)
93 (3.7)
5
238 (9.4)
connection
cover
70
60
SITRANS LR400, dimensions in mm (inch)
Siemens FI 01 · 2012
5/253
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400
■ Schematics
DC version
AC version
earth terminal
cable clamp
Hand Programmer
earth terminal
cable clamp
HART
HART
SITRANS LR400
Part number:
7ML5830-2AJ
5
earth terminal
cable clamp
earth terminal
cable clamp
PROFIBUS PA
PROFIBUS PA
Notes
•
•
•
•
•
recommended torque on terminal clamping screws, 0.5 ... 0.6 Nm
4 ... 20 mA, Profibus PA, DC input circuits, 14-20 AWG, shielded copper wire
AC input circuit, min. 14 AWG copper wire
all field wiring must have insulation suitable for at least 250 V
the equipment must be protected by a 15 A fuse or circuit breaker in the building installation
SITRANS LR400 connections
5/254
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR400 Specials
SITRANS LR400 Specials
SITRANS LR400 Specials
Order No.
Order No.
3"/80 mm Universal Flange,
without horn or hub. See note 1.
PBD51035813
4"/100 mm Universal Flange,
without horn or hub. See note 1.
PBD51035814
6"/150 mm Universal Flange,
without horn or hub. See note 1.
PBD51035815
8"/200 mm Universal Flange,
without horn or hub. See note 1.
PBD51035816
Purging kit with Easy Aimer ball,
no flange, no horn. See note 1.
PBD51036110
Purging kit with Easy Aimer ball
with 4"/100 mm flange, no horn.
See note 1.
PBD51035810
Purging kit with Easy Aimer ball
with 6"/150 mm flange, no horn.
See note 1.
PBD51035811
Purging Kit with Easy Aimer ball
with 8"/200 mm flange, no horn.
See note 1.
PBD51035812
Short horn antenna, no emitter
supplied
PBD22475K1A
Long horn antenna, no emitter
supplied
PBD22475K2A
Short horn antenna, purged, no
emitter supplied
PBD22475K3A
Long horn antenna, purged, no
emitter supplied
PBD22475K4A
Replacement display module,
SITRANS LR400 Liquids and Solids versions
PBD51035410
4" extension kit for horn antenna
with General Purpose approvals
PBD51035474
8" extension kit for horn antenna
with General Purpose approvals
PBD51035473
8" extension kit for horn antenna
for hazardous units
PBD51036180
SITRANS LR400 Aluminum
L)
enclosure with AC power, M20
cable inlet, HART communication, and GP, CE, and CETECOM
approvals.
PBD51036479
SITRANS LR400 Aluminum
L)
enclosure with AC power, M20
cable inlet, PROFIBUS PA communication and GP, CE, and
CETECOM approvals.
PBD51036480
SITRANS LR400 Aluminum
L)
enclosure with AC power, M20
cable inlet, HART communication
and GP, CE, CSA, Industry Canada, FCC and R&TTE.
PBD51035867
SITRANS LR400 Aluminum
L)
enclosure with AC power, M20
cable inlet, PROFIBUS PA communication and GP, CE, CSA,
Industry Canada, FCC and
R&TTE.
PBD51035871
SITRANS LR400 Aluminum
L)
enclosure with AC power, M20
cable inlet, PROFIBUS PA communication and ATEX II 1/2 GD
EEx d IIC T6, CE and R&TTE
approvals.
PBD51035873
SITRANS LR400 Aluminum
enclosure with DC power, M20
cable inlet, HART communication
and and GP, CE and CETECOM
approvals.
PBD51036481
SITRANS LR400 Aluminum
L)
enclosure with DC power, M20
cable inlet, PROFIBUS PA communication and GP, CE and
CETECOM approvals.
PBD51036482
SITRANS LR400 Aluminum
L)
enclosure with DC power, M20
cable inlet, HART communication
and GP, CE, CSA, Industry Canada, FCC and R&TTE
PBD51036483
SITRANS LR400 Aluminum
L)
enclosure with DC power, M20
cable inlet, PROFIBUS PA communication and GP, CE, CSA,
Industry Canada, FCC and
R&TTE.
PBD51036484
SITRANS LR400 Aluminum
L)
enclosure with DC power, M20
cable inlet, HART communication
and ATEX II 1/2 GD EEx d IIC T6,
CE and R&TTE approvals.
PBD51036485
SITRANS LR400 Aluminum
L)
enclosure with DC power, M20
cable inlet, PROFIBUS PA communication and ATEX II 1/2 GD
EEx d IIC T6, CE and R&TTE
approvals.
PBD51036486
1)
2)
5
Available with no pressure rating and with General Purpose approvals only
Subject to export regulations AL: N, ECCN: 3A991X.
Please contact [email protected] for special requests.
L) Subject to export regulations AL: N, ECCN: 3A991X.
Siemens FI 01 · 2012
5/255
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR460
■ Overview
■ Application
SITRANS LR460 provides excellent results even during conditions of extreme dust. The integral Easy Aimer included on the
SITRANS LR460 allows for easy positioning for optimum measurement on solids.
Process Intelligence onboard SITRANS LR460 means advanced
signal processing is harnessed for reliable operation on both
simple and difficult solids application.
SITRANS LR460 features a robust enclosure, flange and horn
components. It is virtually unaffected by atmospheric or temperature conditions within the vessel.
An optional dust cap is available for sticky solids. Optional air
purging is also available for extremely sticky applications.
Safe on-site local programming is simple using the Intrinsically
Safe handheld programmer. SIMATIC PDM can be used for easy
remote programming using HART or PROFIBUS PA.
■ Benefits
• Process Intelligence for advanced signal processing and
quick and easy adjustment
• Self-guided quick start wizard for plug and play start-up
• 24 GHz provides superior reflective properties on solids
surfaces
• 100 m (328 ft) range for long-range and difficult applications
• Easy Aimer optimizes signal quality on sloped surfaces
• Programming using infrared Intrinsically Safe handheld programmer or with SIMATIC PDM or HART handheld device
■ Configuration
Beam angle
Mounting unit on vessel
Installation in
Mounting Nozzle
4" horn
8°
11° 3" horn
Conical
Note: For best signal, always use largest horn size possible.
SITRANS LR460 installation, dimensions in mm (inch)
5/256
Siemens FI 01 · 2012
Positioning with
Easy Aimer
10
(0.39)
5
The SITRANS LR460 is a 4-wire, 24 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of solids up to
100 m (328 ft). It is ideal for measurement in extreme dust.
The characteristics of 24 GHz and high signal-to-noise ratio contribute to exceptional signal reflection, regardless of the dielectric value of the medium.
• Key applications: long-range dusty applications, cement
powder, fly-ash, coal, flour, grain, plastics
Flat
Parabolic
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR460
■ Technical specifications
Mode of operation
Programming
Measuring principle
FMCW radar level measurement
Frequency
24.2 ... 25.2 GHz FMCW
Intrinsically Safe Siemens handheld
programmer (ordered separately)
Infrared receiver
Measuring range
0.35 ... 100 m (1.15 ... 328.08 ft)
• Approvals for handheld
programmer
IS model with ATEX II 1G EEx ia
IIC T4, CSA/FM Class I, Div. 1,
Groups A, B, C, D T6 at
max. ambient temperature of
40 °C (104 °F)
• Signal range
Optically isolated
Handheld communicator
HART Communicator 375
• Load
Max. 600 Ω
PC
SIMATIC PDM
• Fail-safe
mA signal programmable as high,
low or hold (LOE)
Display (local)
Alphanumeric LCD for readout
and entry
Communication
HART, optional PROFIBUS PA
Power supply
Digital output
Relay, NC or NO function,
max. 50 V DC, max. 200 mA,
rating 5 W
100 ... 230 V AC ± 15%
(50/60 Hz), 6 W (12 VA)
or
24 V DC +25/-20%, 6 W (optional)
PROFIBUS PA protocol
Layer 1 and 2, Class A,
Profile 3.01
Output
Analog output (HART)
Performance (Reference
conditions according to
IEC 60770-1)
• Non-linearity
Greater of 25 mm (1 inch) or
0.25% of span (including
hysteresis and non-repeatability),
over the full ambient temperature
range
• Non-repeatability
≤ 10 mm (0.4 inch)
Certificates and approvals
General
CSAUS/C, CE, FM, C-TICK
Radio
European Radio (R&TTE),
Industry Canada, FCC, C-TICK
Hazardous Areas
CSA/FM Class II, Div. 1, Groups
E, F and G, Class III
ATEX II 1D, 1/2 D, 2D T85 °C
INMETRO ExtD A20 IP67 T85 °C
GOST Ex DIP A20 Ta 85°C IP67
Rated operating conditions
Optional equipment
• Amb. temperature for enclosure
-40 ... +65 °C (-40 ... +149 °F)
Dust cap
PTFE
• Location
Indoor/outdoor
Air purge connection
1/8” NPT
• Installation category
II
• Pollution degree
4
Medium conditions
Dielectric constant
εr > 1.4
Process temperature range
-40 ... +200 °C (-40 ... +392 °F)
Vessel pressure
0.5 bar g (7.25 psi g) maximum
Design
Weight
Approx. 6.1 kg (13.4 lb) with
3" universal flange
Materials
• Enclosure
Die-cast aluminum, painted
• Degree of protection
IP67/Type 4X/NEMA 4X/Type
6/NEMA 6
• Cable inlet
2x M20x1.5 or ½" NPT
Process connections
• Universal flanges, 304 stainless
steel, flat faced, with integral Easy
Aimer
3"/80 mm, 4"/100 mm, 6"/150 mm
(mates with flange EN 1092-1,
ASME B16.5, or JIS B2238 bolt
pattern), 0.5 bar g (7.25 psi g)
max. pressure
Siemens FI 01 · 2012
5/257
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR460
Order No.
L) 7ML5426SITRANS LR460
4-wire, 24 GHz FMCW radar level transmitter with
0 7 7 7 0 - 777 0
extremely high signal-to-noise ratio and advanced
signal processing for continuous monitoring of
solids up to 100 m (328 ft). It is ideal for measurement in extreme dust.
Order handheld programmer separately!
Selection and Ordering data
Process connection
Universal, flat faced, 0.5 bar g (7.25 psi g) maximum with integral Easy Aimer ball
3" (80 mm)
4" (100 mm)
6" (150 mm)
Antenna
3" horn antenna, fits 80 mm (3 inch) nozzles
3" horn antenna, fits 80 mm (3 inch) nozzles with
100 mm extension
3" horn antenna, fits 80 mm (3 inch) nozzles with
200 mm extension
5
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification (max. 16
characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Order No.
Operating Instructions
A
B
C
English
C) 7ML1998-5JM02
French
C) 7ML1998-5JM11
German
C) 7ML1998-5JM32
C) 7ML1998-5QW82
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
A
B
C
Accessories
3" horn antenna, fits 80 mm (3 inch) nozzles with
500 mm extension1)
3" horn antenna, fits 80 mm (3 inch) nozzles with
1000 mm extension1)
4" horn antenna, fits 100 mm (4 inch) nozzles
D
Handheld programmer, Infra-red, Intrinsically Safe,
EEx ia
7ML5830-2AJ
E
Dust cap, PTFE, for 3"/80 mm horn
7ML1930-1BL
F
Dust cap, PTFE, for 4"/100 mm horn
4" horn antenna, fits 100 mm (4 inch) nozzles with
100 mm extension
4" horn antenna, fits 100 mm (4 inch) nozzles with
200 mm extension
4" horn antenna, fits 100 mm (4 inch) nozzles with
500 mm extension1)
G
HART modem/RS-232
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DA
H
HART modem/USB
(for use with a PC and SIMATIC PDM)
D) 7MF4997-1DB
J
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART1)
7ML1930-1AP
4" horn antenna, fits 100 mm (4 inch) nozzles with
1000 mm extension1)
K
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA1)
7ML1930-1AQ
Purge (self-cleaning) connection
No purge connection
Purge connection
Output/Communication
4 ... 20 mA, HART
PROFIBUS PA
SITRANS RD100 Remote display - see Chapter 8
0
1
SITRANS RD200 Remote display - see Chapter 8
SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation see Chapter 8
0
1
1)
Power supply/cable inlet
100 ... 230 V AC
• 2 x M20x1.5
• 2 x ½" NPT
A
B
24 V DC
• 2 x M20x1.5
• 2 x ½" NPT
C
D
Approvals
General Purpose, CSAUS/C, Industry Canada, FM,
FCC, CE and R&TTE, C-TICK
CSA/FM Class II, Div. 1, Groups E, F, and G,
Class III
ATEX II 1/2 D T6, CE, R&TTE
1)
Available with Purge option 0 only
L) Subject to export regulations AL: N, ECCN: 3A991X.
5/258
Siemens FI 01 · 2012
7ML1930-1BM
7ML57501AA000
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
A
B
C
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR460
■ Dimensional drawings
SITRANS LR460 (7ML5426)
204 (8.0)
Connection
cover
Electronics
cover
287 (11.29)
Purge connection
Easy Aimer ball locking bolts
Universal slotted flange
Optional horn
extension(s)
100/200/
500/1000
(3.93/7.87/
19.68/39.37)
Reference
point
228 (8.97)
285 (11.22)
5
Horn antenna
74.5
(2.93)
97.5 (3.84)
SITRANS LR460, dimensions in mm (inch)
Siemens FI 01 · 2012
5/259
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR460
■ Schematics
DC version
AC version
earth terminal
cable clamp
Hand Programmer
earth terminal
cable clamp
HART
HART
SITRANS LR460
Part number:
7ML5830-2AJ
5
earth terminal
cable clamp
earth terminal
cable clamp
PROFIBUS PA
PROFIBUS PA
Notes
•
•
•
•
•
recommended torque on terminal clamping screws, 0.5 ... 0.6 Nm
4 ... 20 mA, Profibus PA, DC input circuits, 14 -20 AWG, shielded copper wire
AC input circuit, min. 14 AWG copper wire
all field wiring must have insulation suitable for at least 250 V
the equipment must be protected by a 15 A fuse or circuit breaker in the building installation
SITRANS LR460 connections
5/260
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR260/LR460 Specials
SITRANS LR260/LR460 Specials
SITRANS LR260/LR460 Specials
Order No.
Process connection
part kits - non-pressure-rated
LR260/LR460,100 mm extension for horn
antenna, no purge, see Note 1
A5E01087872
LR260/LR460, 200 mm extension for horn
antenna, no purge, see Note 1
A5E01091262
LR260/LR460,100 mm extension for horn
antenna with purge, see Note 1
A5E01261979
LR260/LR460, 200 mm extension for horn
antenna with purge, see Note 1
A5E01261981
LR260/LR460, horn 2", no purge, no emitter,
see Note 1
A5E02083905
LR260/LR460, horn 3", no purge, no emitter,
see Note 1
A5E01623511
LR260/LR460, horn 4", no purge, no emitter,
see Note 1
A5E01623512
LR260/LR460, horn 2", with purge,
no emitter, see Note 1
A5E02083906
LR260/LR460, horn 3", with purge,
no emitter, see Note 1
A5E01623513
LR260/LR460, horn 4", with purge,
no emitter, see Note 1
A5E01623514
LR260/LR460, 3" universal flat faced flange,
see Note 1
A5E02303897
LR260/LR460, 4" universal flat faced flange,
see Note 1
A5E01259467
LR260/LR460, 6" universal flat faced flange,
see Note 1
A5E01261834
LR260/LR460 O-Rings for Easy Aimer,
see Note 1
Order No.
Enclosure with electronics
LR260 enclosure with board stack,
HART communication, M20 cable inlet,
approval option A, no process connection
C)
A5E02203605
LR260 enclosure with board stack,
PROFIBUS PA communication,
M20 cable inlet, approval option A,
no process connection
C)
A5E02213423
LR260 enclosure with board stack,
HART communication, NPT cable inlet,
approval option A, no process connection
C)
A5E02165924
LR260 enclosure with board stack,
PROFIBUS PA communication,
NPT cable inlet, approval option A,
no process connection
C)
A5E02213428
5
Enclosure with electronics ( LR460)
F)
A5E01261836
Kit, Emitter for LR260/LR460, see Note 1
A5E02360694
LR260 lid with O-ring
A5E02465410
Purge conversion kit – non-pressurerated (no flange or extension included)
LR260/LR460 purge conversion, 2" horn,
see Note 1
A5E02083914
LR260/LR460 purge conversion, 3" horn,
see Note 1
A5E02083915
LR260/LR460 purge conversion, 4" horn,
see Note 1
A5E02083916
LR460 enclosure with board stack,
HART communication, AC power,
M20 cable inlet, approval option A,
no process connection
L)
A5E02182085
LR460 enclosure with board stack,
PROFIBUS PA communication, AC power,
M20 cable inlet, approval option A,
no process connection
C)
A5E02212422
LR460 enclosure with board stack,
HART communication, AC power,
NPT cable inlet, approval option A,
no process connection
L)
A5E02212423
LR460 enclosure with board stack,
PROFIBUS PA communication, AC power,
NPT cable inlet, approval option A,
no process connection
L)
A5E02212424
LR460 enclosure with board stack,
HART communication, DC power,
M20 cable inlet, approval option A,
no process connection
L)
A5E02212425
LR460 enclosure with board stack,
PROFIBUS PA communication, DC power,
M20 cable inlet, approval option A,
no process connection
L)
A5E02212426
LR460 enclosure with board stack,
HART communication, DC power,
NPT cable inlet, approval option A,
no process connection
L)
A5E02212428
LR460 enclosure with board stack,
PROFIBUS PA communication, DC power,
NPT cable inlet, approval option A,
no process connection
L)
A5E02212429
1)
Available with no pressure rating, 0.5 bar g maximum.
Please contact [email protected] for special requests.
C) Subject to export regulations AL: N, ECCN: EAR99.
F) Subject to export regulations AL: 91999, ECCN: N.
L) Subject to export regulations AL: N, ECCN: 3A991X.
Siemens FI 01 · 2012
5/261
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560
■ Overview
■ Configuration
Installation
Note:
• beam angle is the width of the
cone where the energy
density is half of the peak
energy density
emission
• the peak energy density cone
is directly in front of and
in line with the antenna
• there is signal transmitted
outside of the beam angle;
therefore false targets may be
detected
4°
SITRANS LR560 2-wire, 78 GHz FMCW radar level transmitter for
continuous monitoring of solids in silos to a range of 100 m
(329 ft).
5
■ Benefits
• rugged stainless steel design for industrial applications
• 78 GHz high frequency provides very narrow beam, virtually
no mounting nozzle noise, and optimal reflection from sloped
solids
• aimer option to direct beam to area of interest, such as draw
point of cone
• lens antenna is highly resistant to product build up
• air purge connection is included for self-cleaning of extremely
sticky solids
• local display interface (LDI) allows local programming and
diagnostics
Aiming is rarely
required for signal
optimization with
78 GHz frequency.
■ Application
SITRANS LR560’s plug and play performance is ideal for most
solids applications, including those with extreme dust and high
temperatures to 200 ºC (392 ºF). Unique design allows safe and
simple programming using the Intrinsically Safe handheld programmer without having to open the instrument’s lid.
SITRANS LR560 includes an optional graphical local display interface (LDI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile display for diagnostic
support. Startup is easy using the Quick Start wizard with a few
parameters required for basic operation.
SITRANS LR560 measures practically any solids material to a
range of 100 m (328 ft).
• Key Applications: cement powder, plastic powder/pellets,
grain, coal, wood powder, fly ash
Aiming will assist in measuring
material in the cone
SITRANS LR560 installation
5/262
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560
■ Technical specifications
Mode of operation
Power supply
Measuring principle
Radar level measurement
Frequency
78 GHz FMCW
Minimum detectable distance
400 mm (15.75 inch) from sensor
reference point
Maximum measuring range1)
• 40 m (131 ft) version
• 100 m (328 ft) version
4 ... 20 mA/HART
Nominal 24 V DC (max. 30 V DC)
with max. 550 Ω
PROFIBUS PA/Foundation Fieldbus
13.5 mA
9 ... 32 V DC, per IEC 61158-2
Certificates and approvals
• General
CSAUS/C, CE, FM
• Radio
Output
• Analog output
4 ... 20 mA
• Communications
• HART
• Optional: PROFIBUS PA
• Optional: Foundation Fieldbus
• Fail-safe
Europe (R&TTE), FCC, Industry
Canada, C-TICK
Hazardous
• Europe/International
IECEx SIR 09.0149X
ATEX II 1D, 1/2D, 2D
Ex ta IIIC T139ºC Da IP68
ATEX II 3G
Ex nA II T4 Gc
Ex nL IIC T4 Gc
• US/Canada
FM/CSA Class II, Div. 1,
Groups E, F, G
Class III T4
FM/CSA Class I, Div. 2,
Groups A, B, C, D, T4
• China
NEPSI
Ex nA II T4
Ex nL IIC T4
DIP A20 TA, T139ºC, IP68
• Brazil
INMETRO
BR-Ex nA/nL II T4 IP68
• Programmable as high, low or
hold (Loss of Echo)
• NE43 programmable
Performance (according to
reference conditions IEC60770-1)
• Maximum measured error
(including hysteresis and
non-repeatability)
• Greater of 25 mm (1 inch) or
0.25 % of range from minimum
detectable distance to full range
Rated operating conditions
(according to reference
conditions IEC60770-1)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
Programming
• ambient temperature
-40 ... +80 °C (-40 ... +176 °F)
• installation category
I
• pollution degree
4
Intrinsically Safe Siemens handheld
programmer
Infrared receiver
• Approvals for handheld
programmer
IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T = 135 °C
Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1.,
Gr. A-G, T6 Ta = 50 °C
Design
Handheld communicator
HART communicator 375/475
Enclosure
PC
SIMATIC PDM, AMS, PACTware
Display (local)
Graphic local user interface
including quick start wizard and
echo profile displays
Medium conditions
• Dielectric constant εr
> 2.0
Process temperature and pressure
See chart below
• Construction
316L/1.4404 stainless steel
• Conduit entry
M20x1.5, or ½" NPT via adapter
• Lens material
• 40 m version: PEI
• 100 m version: PEEK
• Degree of protection
Type 4X/NEMA 4X, Type 6/
NEMA 6, IP68 with lid closed
• Weight
3.15 kg (6.94 lb) including
3" flange
• Optional local display interface
Graphic LCD, with bar graph
representing level
Process connections
Universal flat-faced
Aimer flanges2)
flanges2)
• 3, 4, 6"/80, 100, 150 mm,
304 stainless steel
• 3, 4, 6"/80, 100, 150 mm,
316L/1.4404 or 316L/1.4435
stainless steel
1)
2)
From sensor reference point
Universal flange mates with EN 1092-1 (PN16)/ASME B16.5
(150 lb)/JIS 2220 (10K) bolt hole pattern.
Process temperature and pressure
Version
Stainless steel
Aimer flange:
-1 ... 0.5 bar
Aimer flange:
-1 ... 3.0 bar
40 m
-40 ... +100 °C
(-40 ... +212 °F)
-40 ... +100 °C
(-40 ... +212 °F)
-40 ... +100 °C
(-40 ... +212 °F)
100 m
-40 ... +200 °C
(-40 ... +392 °F)
-40 ... +200 °C
(-40 ... +392 °F)
-40 ... +120 °C
(-40 ... +248 °F)
3, 4, 6"/80, 100, 150 mm,
polyurethane powder-coated cast
aluminum
Siemens FI 01 · 2012
5/263
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560
Selection and Ordering data
Order No.
L) 7ML5440SITRANS LR560
2-wire, 78 GHz FMCW radar level transmitter for
7 7 7 0 0 - 777 7
continuous monitoring of solids in silos to a range
of 100 m (329 ft).
Order handheld programmer separately!
Measurement and process temperature range
40 m (131 ft) max range, -40 ... +100 °C
100 m (329 ft) max range, -40 ... +200 °C
0
1
Process connection
Universal flat-faced flange fits ANSI/DIN/JIS
flanges
5
3"/80 mm, 304 stainless steel
4"/100 mm, 304 stainless steel
6"/150 mm, 304 stainless steel
A
3"/80 mm, 316L stainless steel
4"/100 mm, 316L stainless steel
6"/150 mm, 316L stainless steel
D
E
F
3"/80 mm, painted aluminum, with integral aimer1)
4"/100 mm, painted aluminum, with integral aimer1)
6"/150 mm, painted aluminum, with integral aimer1)
G
H
J
Enclosure (with cable inlet)
Stainless Steel, 1 X ½" NPT
Stainless Steel, 1 X M20 x 1.5
(plastic gland included)
B
C
Please add "-Z" to Order No. and specify Order
code(s).
Plug M12 with mating connector1)2)3)
Plug 7/8" with mating connector2)4)4)
A50
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters); specify in plain text
Y15
Test certificate: Manufacturer's test certificate M to
DIN 55350, Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 102045)
NAMUR NE43 compliant, device preset to failsafe
< 3.6 mA6)
C12
A55
N07
Order No.
English
C) 7ML1998-5KB01
German
C) 7ML1998-5KB31
C) 7ML1998-5XF81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
A
B
Output/communication
4 to 20 mA, HART
PROFIBUS PA
Foundation Fieldbus
Approvals
General Purpose, CSAUS/C, Industry Canada, FCC,
CE, R&TTE, C-TICK
CSA/FM Class I, Div. 2, Gr. A,B,C,D, Class II, Div.1,
Gr. E,F,G, Class III
ATEX II 1 D, ½ D, 2 D, 3G Ex nA/nL, CE, R&TTE,
C-TICK
Local display interface
Without LDI (local display interface)
With LDI (local display interface)
Rated to 120 ºC max. when used with Pressure rating option 1
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
Further designs
Operating Instructions for HART device
Pressure rating
0.5 bar g (7.5 psi g) maximum
3 bar g (40 psi g) maximum
1)
Order code
Selection and Ordering data
English
C) 7ML1998-5LT01
German
C) 7ML1998-5LT31
C) 7ML1998-5XQ81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
0
1
Operating Instructions for Foundation Fieldbus
device
A
B
C
A
English
C) 7ML1998-5LY01
German
C) 7ML1998-5LY31
C) 7ML1998-5XR81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
B
Accessories
C
1
2
Hand Programmer, Intrinsically safe
C) 7ML1930-1BK
Local display interface
C) 7ML1930-1FJ
Sun Shield Cover
Housing lid with window
7ML1930-1FK
C) 7ML1930-1FL
One metallic cable gland M20x1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART7)
7ML1930-1AP
One metallic cable gland M20x1.5, rated
-40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA7)
7ML1930-1AQ
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
2)
3)
4)
5)
6)
7)
Available with Approval option A only
Available with Enclosure option B only
Available with Output/communication options B and C only
Available with Enclosure option A only
Available with Pressure rating option 1 only
Available with Output/communication option A only
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
L) Subject to export regulations AL: N, ECCN: 3A991X.
5/264
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560
■ Options
Handheld programmer
Sun Shield Cover
Part number:
7ML1930-1BK
Part number:
7ML1930-1FK
SITRANS LR560 handheld programmer and sun shield cover
5
Siemens FI 01 · 2012
5/265
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560
■ Characteristic curves
Temperature derating curve
Ambient
temperature
90
80
Ambient temperature (°C)
70
Process
temperature
60
50
40
30
5
40 m
version
100 m
version
20
10
0
50
100
200
150
250
Process temperature (°C)
SITRANS LR560 temperature derating curve
■ Dimensional drawings
Flat flange
3" aimer flange
4 and 6" aimer flange*
Lid lock
Cable gland
Cable gland
Cable gland
176
(6.93)
Grounding lug
Crounding
lug
Purge plug
166.1
(6.54)
Grounding lug
Purge plug
166.1
(6.54)
Purge plug
Process
connection:
3" aimer
flange
Process
connection:
flat flange
110 (4.33)
200 (7.87)
Sensor
reference
point
22.3
(0.92)
110
(4.33)
9.6
(0.38)
Process
connection:
4 and 6"
aimer flange
4": 229
(9.02)
6": 285
(11.22)
229
(9.02)
A
110
(4.33)
9.6
(0.38)
10º max.
* C Spanner wrench included
29
716
027
A5E
SITRANS LR560, dimensions in mm (inch)
5/266
Siemens FI 01 · 2012
5º max.
4"
6"
A
53.2 (2.09)
60 (2.36)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Radar transmitters
SITRANS LR560 Specials
■ Schematics
SITRANS LR560 Specials
Order No.
LR560 Electronics Modules
cable gland
(or NPTcable entry)
cable shield (if used)
Connect the wires
to the terminals as
shown: the polarity
is identified on the
terminal block.
LR560 Electronics Module,HART,100m
range, compatible with
7ML54401XX00XAXX, no enclosure or
process connection included.
C) 7ML1830-3AC
LR560 Electronics Module,PROFIBUS
PA,100m range, compatible with
7ML54401XX00XBXX, no enclosure or
process connection included.
L) 7ML1830-3AH
LR560 Electronics Module,Foundation
Fieldbus,100m range, compatible with
7ML54401XX00XCXX, no enclosure or
process connection included.
L) 7ML1830-3AJ
LR560 Electronics Module,HART,40m range, L) 7ML1830-3AK
compatible with 7ML54400XX00XAXX, no
enclosure or process connection included.
Notes:
1. Depending on the approval rating, glands and plugs may be
supplied with your instrument.
2. DC terminal shall be supplied from a source providing electrical
isolation between the input and output, to meet the applicable safety
requirements of IEC 61010-1.
3. All field wiring must have insulation suitable for rated input voltages.
4. Use shielded twisted pair cable (14 to 22AWG) for HARTversion.
5. Separate cables and conduit may be required to conform to standard
instrumentation wiring practices or electrical codes.
SITRANS LR560 connections
LR560 Electronics Module,PROFIBUS
PA,40m range, compatible with
7ML54400XX00XBXX, no enclosure or
process connection included.
L) 7ML1830-3AL
LR560 Electronics Module,Foundation
Fieldbus,40m range, compatible with
7ML54400XX00XCXX, no enclosure or
process connection included.
L) 7ML1830-3AM
LR560 Miscellaneous Spare Kits
Kit, Lid Gasket, EPDM, LR560
J) 7ML1830-3AA
Kit,Wrench for 4" and 6" Aimers, LR560
C) 7ML1830-3AB
Kit,O-rings for 3" Aimer, LR560
C) 7ML1830-3AD
Kit,O-rings for 4" Aimer, LR560
C) 7ML1830-3AE
Kit,O-rings for 6" Aimer, LR560
C) 7ML1830-3AF
Kit, Lid Screw and Purge Plug set with Hex
Keys, LR560
C) 7ML1830-3AG
Kit,Lid, No Window, LR560
C) 7ML1830-3AP
C) Subject to export regulations AL: N, ECCN: EAR99.
J) Subject to export regulations AL: 91999, ECCN: EAR99.
L) Subject to export regulations AL: N, ECCN: 3A991X.
Please contact [email protected] for special requests.
Siemens FI 01 · 2012
5/267
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
Interface Detection
■ Overview
Introduction
Guided Wave Radar transmitters combine TDR (time domain reflectometry), ETS (equivalent time sampling) and modern low
power circuitry.
Time Domain Reflectometry (TDR)
TDR uses pulses of electromagnetic (EM) energy to measure
distances or levels. When a pulse reaches a dielectric discontinuity (created by media surface), part of the energy is reflected.
The greater the dielectric difference, the greater the amplitude
(strength) of the reflection.
The SITRANS LG200, when used with the Model 7ML1301-6 coaxial probe, is a transmitter capable of measuring both an upper
level and an interface level. The upper liquid must have a dielectric constant between 1.4 and 5 and the two liquids have a difference in dielectric constants greater than 10. A typical application would be oil over water, with the upper layer of oil being
non-conductive with a dielectric constant of approximately 2 and
the lower layer of water being very conductive with a dielectric
constant of approximately 80. This interface measurement can
only be accomplished when the dielectric constant of the upper
medium is lower than the dielectric constant of the lower medium.
In the SITRANS LG200 transmitter, a waveguide with a characteristic impedance in air is used as a probe. When part of the
probe is immersed in a material other than air, there is lower impedance due to the increase in the dielectric. When an EM pulse
is sent down the probe and meets the dielectric discontinuity, a
reflection is generated.
Air: (dk = 1)
Equivalent Time Sampling (ETS)
5
ETS (Equivalent Time Sampling) is used to measure the high
speed, low power EM energy. ETS is critical in the application of
TDR to vessel level measurement technology. The high speed
EM energy (1000 ft/µs) is difficult to measure over short distances and at the resolution required in the process industry.
ETS captures the EM signals in real time (nanoseconds) and reconstructs them in equivalent time (milliseconds), which is much
easier to measure with today's technology.
ETS is accomplished by scanning the waveguide to collect thousands of samples. Approximately 8 scans are taken per second;
each scan gathers more than 30,000 samples.
24 V DC, 4 to 20 mA
loop powered
Transmit pulse
A reflection develops from the
liquid surface.
Air: dK = 1
A small amount of energy
continues down the probe in a
low dielectric fluid.
Media dK > 1.4
5/268
Siemens FI 01 · 2012
Upper
Level
Signal
Low dielectric
medium
(e.g. oil: dk = 2)
Emulsion layer
Interface
Level
Signal
High dielectric
medium
(e.g. water: dk = 80)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
5
Siemens FI 01 · 2012
5/269
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
Guided Wave Radar (Interface) Application Questionnaire
Customer information
Contact:
Prepared By:
Company:
Date:
Address:
Notes on the Application:
City:
Zip/Postal Code:
Country:
Phone: (
)
E-mail:
Fax:
(
)
Tank/Vessel Information
5
Mounting location:
Tank bottom:
Tank top:
Sketch
attached
(supply sketch where possible)
Tank dimensions:
Height:
m/ft
Diameter:
m/ft
Open
Sloped
Top mount
Nozzle Length:
cm/in
Flat
Flat
Thread mount
Nozzle Diameter:
cm/in
Conical
Conical
Flange mount
Process connection type:
Parabolic
Parabolic
Bypass/Sidepipe Mount
Process connection size:
Pipe mount
Distance to sidewall:
Pressure:
cm/in
Displacer replacement
Normal:
(please supply drawings)
Maximum (relief):
Interface Data
Lower material:
Upper material:
Emulsion layer:
Upper material thickness:
cm/in Lower material thickness:
Upper material dielectric:
Lower material dielectric:
cm/in
Emulsion thickness:
Yes
No (preferred)
cm/in
Material
Liquid
Material being measured:
°C/°F Max:
Material temperature: Norm:
Coating buildup:
Yes
Maximum Viscosity:
No
Slurry
°C/°F
Turbulence:
No
Yes
Density:
kg/m
3
3
Kinematic Viscosity (cSt) = Dynamic Viscosity (cP) / Density (kg/m )
1 to 5 cSt (like water)
50 to 100 cSt (like honey)
5 to 20 cSt (like machine oil)
100 to 500 cSt (like syrup/molasses)
20 to 50 cSt (like cooking oil)
>500 cSt (like tar)
emulsion
layer
upper
material
lower
material
Installation
Power available:
Communications:
Outputs required:
HART ® /4 to 20 mA
4 to 20 mA
Other (please specify)
Products recommended:
© Siemens Milltronics Process Instruments Inc.
5/270
Siemens FI 01 · 2012
www.siemens.com/processautomation
Form# 2-938R0
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
■ Overview
■ Benefits
• Coaxial, rigid, and flexible single or twin rods for many applications
• Measures accurately on materials with dielectric (dK) as low
as 1.4 (including LNG at -196 °C (-320.8 °F)
• Guided wave radar measurement for up to 2.5 mm (0.12 inch)
accuracy
• Measures level and interface on challenging applications
including foam
• 3 button programming for quick setup
• Reliable level measurement on harsh applications with pressure up to 430 bar g (6250 psi g) and temperatures as high as
427 °C (800 °F).
• Suitable for use in SIL-1 and SIL-2 Loops (Full FMEDA report
available)
■ Application
SITRANS LG200 is a guided wave radar transmitter for short and
medium range level, level/interface, and volume measurement
of liquids and solids. It is unaffected by changes in process conditions, high temperatures and pressures, and steam.
SITRANS LG200 provides accurate measurement in level,
volume, and interface applications. For short and extended
applications, LG200 offers coaxial, single or twin rod probes,
and single or twin cable probes up to 22.5 m (75 ft).
SITRANS LG200 measures accurately in liquid or slurry applications of corrosive vapors, foam, saturated steam, high viscosity,
quick fill/empty rates, low levels and varying dielectrics and
product densities.
Ideal for retrofitting torque tube applications, SITRANS LG200
chamber replacement probe can be mounted in existing chambers or cages for optimal measurement.
• Key applications: hydrocarbon processing, interface/level
measurement, low dielectric liquids, high temperature/pressure applications, powdered solids with high angle of repose.
Applications on ammonia are also possible with the HT/HP coaxial probe design which incorporates a glass seal that is not
susceptible to the vapors seen in this application.
Siemens FI 01 · 2012
5/271
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
■ Configuration
Mounting on a nozzle
Single Rod mounting
1. Do not mount in nozzles <50 mm (2") in diameter.
2. Mount in applications where ratio of diameter to
length is 1:1 or greater. Any ratio less than 1:1
(i.e. 2" x 6" nozzle = 1:3) may require a blanking
distance and/or dielectric adjustment.
3. Do not use pipe reducers.
4. Keep conductive objects away from probe
to ensure proper performance.
length
diameter
Optimal 1:1 ratio
Twin Rod mounting 7ML1302-x
1. Active rod must be mounted at least 25 mm (1") away from any obstructions.
2. Minimum stillwell or nozzle diameter for probe is 76 mm (3"), inactive part needs
to be flush with inside tank wall.
Installation in non-metallic silos 1)
For installation in vessels of a non-metallic
construction or possibly open vessels, a suitable
launch plate is required to optimize the impedance
of the transmitted signal as it travels along the
probe. Optimal performance cannot be guaranteed
if a suitable transition is not available at the process
connection.
When using single rod versions (flexible or solid)
and a threaded process connection, a metal sheet
or flange will greatly improve conditions as this
provides a suitable launch plate.
A flanged process connection is generally accepted
to be provision of this launch plate.
silo roof
(plastic or wood)
50 (2)
Probe can be stabilized at the bottom with a non-metallic cup or
bracket. When mounting into a metallic cup or bracket, use
optional TFE bottom spacer (7ML1930-1DJ).
Do not use reducers.
3)
4)
50 (2)
5)
5)
6)
Coaxial 7ML1301-x/Coaxial-Interface 7ML1301-6
1. Minimum 25 mm (1") from tank bottom
2. Minimum 2" process connection for enlarged
coaxial probe
3. Distance to obstructions not important due
to enclosed design
metal
sheet or
metal
flange
2)
19 (¾)
7)
6)
Bypass pipe
1. Minimum pipe diameter 50 mm (2")
2. Minimum 25 mm (1") from bottom of the bypass pipe
3. Take note of bottom transition zone for
chosen probe, see probe type table
4. For pipe diameters less than 50 mm (2")
consult factory
Displacer/Torque Tube Replacement
1. With Coaxial Probe 7ML1301-4 there is no top transition zone allowing
measurement to the process connection.
2. Minimum pipe size: coaxial probes 2"/DN50, twin rod 3"/DN80, single rod
2"/DN50
3. 22 mm (0.875") Coaxial probes should be used where limited
build up is expected.
1)
2)
3)
See Electromagnetic compatibility
min. 1" - 150 lbs, DN 25 PN 16
min. 2" - 150 lbs, DN 25 PN 16
4)
5)
6)
min. 3" - 150 lbs, DN 80 PN 16
min. 25 mm (1") from any metal object
min. 25 mm (1") from tank bottom
SITRANS LG200 installation, dimensions in mm (inch)
5/272
Siemens FI 01 · 2012
7)
Customer supplied brackets
Recommended:
1 bracket per 3 m length
L = Probe
Insertion Length
4 mA/0%
M = measuring range:
min. 300 (11.81)
max. 5700 (224)
L=A+M+B
20 mA/100%
min.
25 (1)
A
body connection
B
5
3)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
■ Technical specifications
Mode of operation
Design
Measuring principle
Guided wave radar measurement
Weight of transmitter with solid lid
1.28 kg (2.83 lb)
Measuring range
0.15 ... 22.5 m (0.5 ... 75 ft)
Weight of transmitter with glass
window lid
1.60 kg (3.52 lb)
Output
mA analog output with HART digital
signal
Optically isolated 4 ... 20 mA,
620 Ω max.
Output range
Materials
• Enclosure
Aluminum, epoxy-coated
• Degree of protection
Type 4/NEMA 4, IP65
2x M20x1.5 or 2 x ½" NPT
• Analog
3.8 ... 20.5 mA usable
• Cable inlet
• Start-up current
4.0 mA
Process connections
Diagnostic alarm
Adjustable 3.6 mA, 22 mA, HOLD
• Threaded
Digital communication
HART Version 5.x and multidrop
compatible
G ¾" [(BSPP), EN ISO 228-1], 1",
1½", 2" NPT [(Taper),
ANSI/ASME B1.20.1] and
G 2" [(BSPP), EN ISO 228-1]
Performance
Reference Conditions 1.82 m
(72 inch) Coaxial Probe with
water at 20 °C (70 °F) and
CFD Threshold
• Flanged
3/4" ... 4", ASME, DIN flanges
• Hygenic
3/4" ... 4", Triclover
Non-linearity
• Coaxial/twin rod probes
• Single rod probes
Programming
Local
< 0.1 % of probe length or
2.5 mm (0.1 inch), whichever is
greater
[(top 60 cm (24 inch) of twin rod
probes 30 mm (1.2 inch)]
Three button, menu-driven data
entry with security passwords
Remote
SIMATIC PDM via HART
Power
11 ... 36 V DC
< 0.3 % or 0.3" (8 mm),
whichever is greater
General Purpose
CSA/FM, CE, C-TICK
Intrinsically Safe
FM Class I, Div. 1,
Groups A, B, C, D, Class II, Div. 1,
Groups E, F, G T4, Class III,
Type 4, IP65
CSA Class I, Div. 1, Groups A, B,
C, D, Class II, Div. 1, Groups E, F,
G T4, Class III, Type 4, IP65
ATEX II 1G EEx ia IIC T4
Explosion Proof/Flame Proof
FM Class I, Div 1, Groups B, C, D,
Class II, Div. 1, Groups E, F, G T4,
Class III, Type 4, IP65
CSA Class I, Div. 1, Groups B, C,
D, Class II, Div. 1, Groups E, F,
G T4, Class III, Type 4, IP65
ATEX II 1/2 G EEx d [ia] IIC T6
ATEX II 1/2 D IP65 T85 °C
Non-Incendive
FM Class I, Div. 2, Groups A, B, C,
D, Class II, Div. 2, Groups F, G T4,
Class III, Type 4, IP65
CSA Class I, Div. 2, Groups A, B,
C, D, Class II, Div. 2, Groups E, F,
G T4, Class III, Type 4, IP65
Non-Sparking
ATEX II 3G EEx nA (nL)
IIC T4 to T6
ATEX II 3G EEx nA II T4 to T6
Others
• Functional Safety to SIL-1 in accordance with IEC 61508 Safe
Failure Fraction (SFF) of 85.5%
(Third party FMEDA Analysis –
hardware only)
• Functional Safety to SIL-2 in accordance with IEC 61508 Safe
Failure Fraction (SFF) of 91%
(Third party FMEDA Analysis –
hardware only)
• Lloyds Steam Vessel Approval
conforming to EN 12952-11 &
EN 12953-9
• GOST R
• Interface models
Upper layer: ± 25.4 mm (1 inch)
Interface layer: ± 25.4 mm
(1 inch)
(distinct interface surface
required)
Resolution and repeatability
≤ 2.5 mm (0.1 inch)
Certificates and approvals
Accuracy
• Coaxial/twin rod probes
< 0.1 % of probe length or 0.1"
(2.5 mm), whichever is greater
[Top 60 cm (24 inch) of twin rod
probes 30 mm (1.2 inch)]
• Single rod probes
± 0.5 % of probe length or 0.5"
(13 mm), whichever is greater
• Interface models
± 1" (25 mm)
(distinct Interface required)
Electromagnetic compatibility
Meets CE requirements
(EN 61326-1/2006)
(Single and Twin Rod probes
must be used in metallic vessel or
stilling well to maintain CE compliance.)
• Response time
< 1 second
• Warm up time
< 5 seconds
• Temperature effects
0.02 % of actual probe length/°C
for probes ≥ 2.5 m (8 ft)
Rated operating conditions1)
Ambient temperature for enclosure
-40 ... +80 °C (-40 ... +176 °F)
LCD readable temperature range
-20 ... +70 °C (-5 ... +160 °F)
Location
Indoor/outdoor
Installation category
II
Pollution degree
2
Humidity
0 ... 99 % (non condensing)
Medium conditions1)
Dielectric constant
dK ≥ 1.4
Process temperature range2)
-196 ... +427 °C (-321 ... +800 °F)
Vessel pressure3)
5
1)
If installation is in areas classified as hazardous, please observe relevant
certificates
Temperature rating is pressure dependent
3)
Pressure rating is temperature dependent
2)
Full vacuum to 431 bar g
(6250 psi g), probe dependent
Siemens FI 01 · 2012
5/273
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Coaxial Probe
(7ML1301-1)
Coaxial HT/HP Probe
(7ML1301-2)
Coaxial HP Probe
(7ML1301-3)
Coaxial Overfill/Flooded
Cage Probe (7ML1301-4)
Model reference
number
7xA-x
7xD-x
7xP-x
7xR-x
Recommended
applications
General purpose:
clean, low viscosity liquids
< 150 °C (300 °F)
Clean, high temperature/
high pressure liquids
> 200 °C (400 °F),
ammonia, chlorine, LNG1),
LPG1)
Clean, high pressure liquids
< 200 °C (400 °F),
ammonia, chlorine, LNG,
LPG
General applications,
overfill, temperatures to
200 °C (400 °F), clean, low
viscosity liquids,
displacer/torque-tube
replacement
Not recommended for:
Coating and buildup, foam
Coating and buildup, foam,
steam
Coating and buildup, foam,
steam
Coating and buildup, foam
Materials/wetted parts
316 L SS, TFE spacers,
O-ring2)
316L SS, Alumina spacers3), 316L SS, TFE spacers,
(option PEEK4) or TFE5)),
Borosilicate
Borosilicate
316L SS, TFE spacers,
O-ring2)
Process seal
O-ring2)
Borosilicate (no O-ring)
Borosilicate (no O-ring)
O-ring2)
Standard
ø 8 mm (0.3125 inch) rod
ø 22 mm (0.875 inch) tube
ø 8 mm (0.3125 inch) rod
ø 22 mm (0.875 inch) tube
ø 8 mm (0.3125 inch) rod
ø 22 mm (0.875 inch) tube
ø 8 mm (0.3125 inch) rod
ø 22 mm (0.875 inch) tube
Enlarged
ø 15 mm (0.63 inch) rod
ø 45 mm (1.75 inch) tube
ø 15 mm (0.63 inch) rod
ø 45 mm (1.75 inch) tube
ø 15 mm (0.63 inch) rod
ø 45 mm (1.75 inch) tube
ø 15 mm (0.63 inch) rod
ø 45 mm (1.75 inch) tube
Rod/tube diameter
Process connection thread
5
Standard
¾" NPT [(Taper),
¾" NPT [(Taper),
¾" NPT [(Taper),
¾" NPT [(Taper),
ANSI/ASME B1.20.1],
ANSI/ASME B1.20.1],
ANSI/ASME B1.20.1],
ANSI/ASME B1.20.1],
G 1" [(BSPP), EN ISO 228-1] G 1" [(BSPP), EN ISO 228-1] G 1" [(BSPP), EN ISO 228-1] G 1" [(BSPP), EN ISO 228-1]
Enlarged
2" NPT [(Taper),
ANSI/ASME B1.20.1]
2" NPT [(Taper),
ANSI/ASME B1.20.1]
2" NPT [(Taper),
ANSI/ASME B1.20.1]
2" NPT [(Taper),
ANSI/ASME B1.20.1]
Standard
1 ... 4" (DN 25 ... 100)
1 ... 4" (DN 25 ... 100)
1 ... 4" (DN 25 ... 100)
1 ... 4" (DN 25 ... 100)
Enlarged
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
Length
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
Top
25 mm (1 inch) at dk = 1.4
150 mm (6 inch) at dk = 80
none
25 mm (1 inch) at dk = 1.4
150 mm (6 inch) at dk = 80
none
Bottom
150 mm (6 inch) at dk = 1.4 150 mm (6 inch) at dk = 1.4 150 mm (6 inch) at dk = 1.4 150 mm (6 inch) at dk = 1.4
25 mm (1 inch) at dk = 80
25 mm (1 inch) at dk = 80
25 mm (1 inch) at dk = 80
25 mm (1 inch) at dk = 80
Process temperature
maximum
150 °C at 27 bar g
(300 °F at 400 psi g)
427 °C at 133 bar g
(800 °F at 2000 psi g)7)
200 °C at 379 bar g
(400 °F at 5500 psi g)
200 °C at 18 bar g
(400 °F at 270 psi g)
Process temperature
minimum
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
-196 °C at 430 bar g
(-321 °F at 6250 psi g)
-196 °C at 430 bar g
(-321 °F at 6250 psi g)
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
Process pressure maximum
70 bar g at 20 °C
(1000 psi g at 70 °F)
431 bar g at 20 °C
(6250 psi g at 70 °F)
431 bar g at 20 °C
(6250 psi g at 70 °F)
70 bar g at 20 °C
(1000 psi g at 70 °F)
Process pressure
minimum/vacuum service
Yes, not hermetic8)
Yes, hermetic
(< 10-8 cc/s at
1 atmosphere)
Yes, hermetic
(< 10-8 cc/s at
1 atmosphere)
Yes, not hermetic
Dielectricrange (dk)
1.4 ... 100
1.4 ... 1001)
1.4 ... 100
1.4 ... 100
Standard
500
500
500
500
Enlarged
1500
1500
1500
1500
Coating/buildup
No
No
No
No
Foam
No
No
No
No
Corrosives
Yes
Yes
Yes
Yes
Sanitary
No
No
No
No
Overfill
No
Yes
No
Yes
Flange ASME (EN/DIN)
Transition Zone6)
Process pressure
Maximum viscosity (cP)
1)
2)
3)
4)
5)
6)
7)
8)
Dependent on spacer option
See O-Ring Selection Guide for guidance
For dk ≥ 2, maximum temperature 427 °C (800 °F)
For dk ≥ 1.4, maximum temperature 343 °C (650 °F), PEEK spacers standard on enlarged coaxial design
For dk 1.4, maximum temperature 288 °C (550 °F)
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone
345 °C (650 °F) with PEEK spacers
Not hermetic: sealing by means of O-ring. Hermetic: sealing by means of borosilicate glass window
5/274
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Coaxial Steam Probe
(7ML1301-5)
Coaxial Interface
Probe (7ML1301-6)
Single Rigid Rod
Probe (7ML1303-1)
Single Rigid Rod
HT/HP Probe
(7ML1303-2)
Single Rigid Rod
Probe, PFA rod insulation (7ML1303-1J)
Model reference
number
7xS-x
7xT-x
7xF-x
7xJ-x
7xF-4
Recommended
applications
Hot water (steam)
>200 °C (400 °F)
(external chamber is
required for use in
boilers)
Liquid/liquid-interface,
temperatures
to 200 °C (400 °F);
clean, low-viscosity
liquids
Coating and buildup,
foam
Coating and buildup,
foam
Excessive coating and
buildup, foam
Not recommended for
General purpose, coat- Coating and buildup,
ing and buildup, foam
foam
Low dielectric media
(dK < 10)1)
Low dielectric media
(dK < 10)1)
Low dielectric media
(dK < 10)1)
Materials/wetted parts
316L SS, PEEK
spacers, Aegis PF128
O-ring2)
316L SS, TFE spacers,
O-ring2)
316L SS, TFE, O-ring2)
316L SS, TFE, O-ring2)
316L SS, PFA, TFE,
O-ring2)
Process seal
Aegis PF128 O-ring2),
PEEK only
O-ring2)
O-ring2)
Aegis PF128
O-ring only2)
O-ring2)
Standard
ø 8 mm (0.3125 inch)
rod
ø 22 mm (0.875 inch)
tube
ø 8 mm (0.3125 inch)
rod
ø 22 mm (0.875 inch)
tube
ø 12 mm (0.5 inch) rod
ø 12 mm (0.5 inch) rod
ø 12 mm (0.5 inch) rod
ø 16 mm (0.625 inch)
insulation
Enlarged
N/A
ø 15 mm (0.63 inch) rod N/A
ø 45 mm (1.75 inch)
tube
N/A
N/A
Standard
¾" NPT [(Taper),
ANSI/ASME B1.20.1],
G 1" [(BSPP),
EN ISO 228-1]
¾" NPT [(Taper),
ANSI/ASME B1.20.1],
G 1" [(BSPP),
EN ISO 228-1]
¾" NPT [(Taper),
ANSI/ASME B1.20.1],
G 1" [(BSPP),
EN ISO 228-1]
¾" NPT [(Taper),
ANSI/ASME B1.20.1],
G 1" [(BSPP),
EN ISO 228-1]
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
Enlarged
N/A
2" NPT [(Taper),
ANSI/ASME B1.20.1]
N/A
N/A
N/A
Standard
1 ... 4" (DN 25 ... 100)
1 ... 4" (DN 25 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
Enlarged
N/A
2 ... 4" (DN 50 ... 100)
N/A
N/A
N/A
Length
60 ... 455 cm
(24 ... 180 inch)
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
Top
25 mm (1 inch) at
dk ≥ 10
none
Application, installation, Application, installation, Application, installation,
and dielectric depenand dielectric depenand dielectric dependent
dent
dent
Bottom
25 mm (1 inch)
at dk ≥ 10
150 mm (6 inch)
at dk = 1.4
25 mm (1 inch)
at dk = 80
25 mm (1 inch)
’at dk >10
Process temperature
maximum
343 °C at 165 bar g
(650 °F at 2400 psi g)
(saturated steam)
200 °C at 18 bar g
(400 °F at 270 psi g)
150 °C at 27 bar g (300 316 °C at 165 bar g
°F at 400 psi g)
(605 °F at 2400 psi g)
150 °C at 27 bar g
(300 °F at 400 psi g)
Process temperature
minimum
-40 °C at 207 bar g
(-40 °F at 3000 psi g)
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
-40 °C at 50 bar g
(-40 °F at 750 psi g)
Process pressure
maximum
165 bar g at 343 °C
(2400 psi g at 650 °F)
70 bar g at 20 °C
(1000 psi g at 70°F)
70 bar g at 20 °C
(1000 psi g at 70 °F)
207 bar g at 20 °C
(3000 psi g at 70 °F)
70 bar g at 20 °C
(1000 psi g at 70 °F)
Process pressure min.
vacuum service
Yes, not hermetic
Yes, not hermetic
Not suitable
Not suitable
Not suitable
Dielectric range
10 ... 100
Upper liquid layer
1.4 ... 5
Interface liquid layer
15 ... 100
1.9 ... 1001)
1.9 ... 1001)
1.9 ... 1001)
10000 cP (consult factory if severe agitation/turbulence)
Rod/Tube diameter
5
Process connection
thread
Flange ASME (EN/DIN)
Transition Zone3)
25 mm (1 inch)
at dk >10
25 mm (1 inch)
at dk >10
Maximumviscosity
Standard
500 cP
500 cP
Enlarged
N/A
1500 cP
Coating/buildup
No
No
Yes, maximum error 10% of coated length;% error related to dielectric of
media, thickness of coating and coated probe length above media
Foam
No
No
Yes
Yes
Yes
Corrosives
Yes
Yes
Yes
Yes
Yes
Sanitary
No
No
No
No
No
Overfill
Yes
Yes
No
No
No
1)
With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6 inch) of metal tank wall or in chamber/bridle
2)
See O-ring Selection Guide for guidance
3)
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone
Siemens FI 01 · 2012
5/275
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
5
Single Rigid Rod Probe,
Sanitary (7ML1303-1D)
Single Rigid Rod Probe,
PFA faced flange
(7ML1303-1E)
Single Flexible Rod Probe Single Flexible Rod Probe
(7ML1304-1)
for Bulk Solids (7ML1304-2)
Model reference number
7xF-E
7xF-F
7x1-x
7x2-x
Recommended
applications:
Applications demanding
sanitary specifications
Extreme corrosives,
coating/buildup, foam
Coating and buildup, foam;
lengths > 6 m (20 ft) headroom
Granular bulk solids applications (powders, grain, dust)
3000 lb pull down force
Not recommended for
Low dielectric media
(dK < 10)1)
Low dielectric media
(dK < 10)1)
Low dielectric media
(dK < 4)
Solids with dK < 4
Materials/wetted parts
316L SS, TFE, 15 µ-inch
(< 0.4 µm) Ra
All PFA - wetted surfaces
316L SS, TFE, O-ring2)
316L SS, TFE, O-ring2)
Optional
AL6XN SS
N/A
N/A
N/A
Process seal
316L SS, TFE, O-ring2)
PFA, no O-ring
O-ring2)
Sealant
Rod/tube diameter
ø 12 mm (0.5 inch) rod
ø 12 mm (0.5 inch) rod
ø 16 mm (0.625 inch)
insulation
ø 5 mm (0.188 inch) cable
ø 6 mm (0.25 inch) cable
Process connection thread
N/A
N/A
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
Flange ASME (DIN)
19 ... 100 mm (¾ ... 4 inch)
Triclover-style 16 amp
fitting
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
Length
60 ... 610 cm
(24 ... 240 inch)
60 ... 610 cm
(24 ... 240 inch)
1 ... 22.5 meters (3 ... 75 ft)
1 ... 22.5 meters (3 ... 75 ft)
Transition Zone3)
Top
Application, installation, and Application, installation, and Application, installation, and Application, installation, and
dielectric dependent
dielectric dependent
dielectric dependent
dielectric dependent
Bottom
25 mm (1 inch) at dk >10
25 mm (1 inch) at dk >10
305 mm (12 inch)
305 mm (12 inch)
Process temperature
maximum
150 °C at 5.1 bar g
(300 °F at 75 psi g)
150 °C at 27 bar g
(300 °F at 400 psi g)
150 °C at 27 bar g
(300 °F at 400 psi g)
66 °C at 3.4 bar g
(150 °F at 50 psi g)
Process temperature
minimum
0 °C at 5.1 bar g
(32 °F at 75 psi g)
-40 °C at 13.7 bar g
(-40 °F at 200 psi g)
-40 °C at 70 bar g
(-40 °F at 1000 psi g)
-40 °C at 3.4 bar g
(-40 °F at 50 psi g)
• Process pressure
maximum
5.1 bar g at 150 °C
(75 psi g at 300 °F)
70 bar g at 20 °C
(1000 psi g at 70°F)
70 bar g at 20 °C
(1000 psi g at 70 °F)
3.4 bar g 66 °C
(50 psi g at 150 °F)
• Process pressure
minimum/vacuum service
Not suitable for vacuum applications
Dielectric range
1.9 ... 1001)
4 ... 1001)
4 ... 100
Maximum viscosity (cP)
10000 (consult factory if severe agitation/turbulence)
Coating/buildup
Yes, maximum error 10% of coated length; % error related to dielectric of media, thickness of coating and coated
probe length above media
Process pressure:
1.9 ... 1001)
N/A
Foam
Yes
Yes
Yes
Yes
Corrosives
No
Yes
No
No
Sanitary
Yes
No
No
No
Overfill
No
No
No
No
1)
2)
3)
With dK of 1.9 to 10, the device must be mounted between 50 and 150 mm (2 to 6 inch) of metal tank wall or in chamber/bridle
See O-ring Selection Guide for guidance
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone
5/276
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Twin Rod Probe
(7ML1302-1)
Flexible Twin Rod Probe
(7ML1302-3)
Flexible Twin Rod Bulk Solids
Probe (7ML1302-2)
Model reference
number
7xB-x
7x7-x
7x5-x
Recommended applications:
General purpose, foam, minor film
coating
Low dielectric media (1.9 ... 10) with Granular light bulk solids applicalengths > 6 m (20 ft)
tions (powders, grains, dust),
3000 lbs pull-down force
Not recommended for
Media bridging between rods or
building up on spacers
Dielectric > 10: media bridging on
flexible elements
Media bridging flexible elements
Materials/wetted parts
316L SS, TFE spacers, O-ring1)
316L SS, FEP webbing, O-ring1)
316L SS, FEP webbing, O-ring1)
Process seal
O-ring1)
O-ring1)
Sealant
Rod/tube diameter
Two, ø 12 mm (0.5 inch) rod;
22 mm (0.875 inch) CL ... CL
Two, ø 6 mm (0.25 inch) cables;
22 mm (0.875 inch) CL ... CL
Two, ø 6 mm (0.25 inch) cables;
22 mm (0.875 inch) CL ... CL
Process connection thread
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
2" NPT [(Taper),
ANSI/ASME B1.20.1],
G 2" [(BSPP),
EN ISO 228-1]
Flange ASME (EN/DIN)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
2 ... 4" (DN 50 ... 100)
Length
60 ... 610 cm (24 ... 240 inch)
1 ... 22.5 m (3 ... 75 ft)
1 ... 22.5 m (3 ... 75 ft)
Top
150 mm (6 inch) at dK > 1.9
Blocking distance: none
150 mm (6 inch) at dK > 1.9
Blocking distance: 12 ... 50 cm
(4.8 ... 20 inch)
150 mm (6 inch) at dK > 1.9
Blocking distance: 12 ... 50 cm
(4.8 ... 20 inch)
Bottom
150 mm (6 inch) at dK = 1.9
25 mm (1 inch) at dK = 80
305 mm (12 inch)
305 mm (12 inch)
Process temperature max.3)
200 °C at 19 bar g (400 °F at 275 psi g)
66 °C at 3.4 bar g
( 150 °F at 50 psi g)
Process temperature min.
-40 °C at 70 bar g (-40 °F at 1000 psi g)
-40 °C at 3.4 bar g
(-40 °F at 50 psi g)
Process pressure max.
70 bar g at 20 °C (1000 psi g at 70 °F)
3.4 bar g at 66 °C
(50 psi g at 150 °F)
Process pressure min./vacuum
service
Yes, not hermetic
Not suitable
Dielectric range
1.9 ... 100
1.9 ... 100
1.9 ... 100
Maximum viscosity (cP)
1500
1500
Not suitable
Coating/buildup
Yes, maximum error 3% of coated length with conductive media
Bridging not recommended.4)
Foam
Yes
Yes
Yes
Corrosives
Yes
No
Yes
Sanitary
No
No
No
Overfill
No
No
No
Transition Zone2)
1)
See O-ring Selection Guide for guidance
Transition zone is dielectric dependent: dK = dielectric permittivity. Unit will function but accuracy will decrease in Transition Zone
Refer to Ambient Temperature vs Process Temperature graphs or instruction manual
4)
Bridging is defined as continuous accumulation of material between the probe elements
2)
3)
O-ring and Seal Selection Guide
Material
Recommended for Use in:
Not Recommended for Use In:
Viton GFLT
General purpose, steam, ethylene
Ketones (MEK, acetone), skydrol fluids, amines,
anhydrous ammonia, low molecular weight
esters and ethers, hot hydrofluoric or chlorosulfuric acids, sour HCs
EPDM
Acetone, MEK, skydrol fluids
Petroleum oils, di-ester base lubricants,
propane, steam, anhydrous ammonia
Kalrez (4079)
Inorganic and organic acids (including HF and Black liquor, hot water/steam, hot aliphatic
nitric) aldehydes, ethylene, glycols, organic oils, amines, ethylene oxide, propylene oxide, molten
silicone oils, vinegar, sour HCs
sodium, molten potassium, anhydrous ammonia
Aegis PF128
Inorganic and organic acids (including HF and Black liquor, Freon 43, Freon 75, Galden,
nitric) aldehydes, ethylene, glycols, organic oils, KEL-F liquid, molten sodium, molten potassium,
silicone oils, vinegar, sour HCs, steam, amines, anhydrous ammonia
ethylene oxide, propylene oxide
Borosilicate
(HT/HP probes only)
General high temperature/high pressure applications, hydrocarbons, full vacuum (hermetic),
anhydrous ammonia
Steam, hot alkaline solutions, HF acid, media
with pH>12, condensate
Siemens FI 01 · 2012
5/277
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
Selection and Ordering data
C) 7ML1300SITRANS LG200 Transmitter
A guided wave radar transmitter for short and
77 7 1 7 - 77 A 0
medium range level, level/interface, and volume
measurement of liquids and solids, including high
temperature and pressure applications, and
steam.
Note:
In addition to the transmitter, please select a
probe configuration to complete the
SITRANS LG200 (ordered separately).
For orders of 10 or more, please consult
factory.
Power
24 V DC, 2-wire
Signal Output
4 ... 20 mA HART
Options
SIL-1 Approved (FMEDA analysis) SFF = 85.5 %
SIL-2 Approved (FMEDA analysis) SFF = 91 %
5
Enclosure/lid
Aluminum
Aluminum with glass window
Cable inlet
2 x ½" NPT, IP65
2 x M20x1.5, IP65
Approvals (Please select for your region)
North America
General Purpose and Intrinsically Safe (CSA/FM
Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1,
Groups E, F, G T4, Class III); Non-incendive
(CSA Class I, Div. 2, Groups A, B, C, D, Class II,
Div. 2, Groups E, F, G; FM Class I, Div. 2,
Groups A, B, C, D, Class II, Div. 2, Groups F, G)
Explosion Proof (CSA/FM Class I, Div. 1, Groups B,
C, and D; Class II, Div. 1, Groups E, F, G, T4;
Class III); Non-incendive (CSA Class I, Div. 2,
Groups A, B, C, D, Class II, Div. 2, Groups E, F, G;
FM Class I, Div. 2, Groups A, B, C, D, Class II, Div.
2, Groups F, G)
Europe
General Purpose and Intrinsically Safe (ATEX II 1G
EEx ia IIC T4)
Explosion Proof (ATEX II 1/2 GD EEx d [ia] IIC T6)
Non-sparking [ATEX II 3G EEx nA II/EEx nA (nL)
IIC T4 to T6]
C) Subject to export regulations AL: N, ECCN: EAR99.
5/278
Siemens FI 01 · 2012
Please add "-Z" to Order No. and specify Order
code(s).
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
[Available only when ordered in conjunction with a
probe (7ML130x-x). Testing requires transmitter
with probe.]
Operating Instructions
1
Order code
Further designs
C11
Order No.
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
A
Accessories
A
B
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
1
2
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA0-00
see Chapter 8
0
1
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
A
B
C
D
E
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
.
Selection and Ordering data
Order No.
R) 7ML1301SITRANS LG200 Coaxial Probes
SITRANS LG200 coaxial probes are used in most
77 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric
applications (dK 1.4 ... 100).
1
2
3
Coaxial, Overfill/Flooded Cage1)2)
Coaxial Steam4)5)
Coaxial, Interface1)2)
4
5
6
Material of Construction
316/316L (1.4401/1.4404) stainless steel probe
and process connection
316/316L (1.4401/1.4404) SS probe ASME B31.1
specifications6)
Enlarged Coaxial, 316/316L (1.4401/1.4404)
stainless steel probe and process connection with
PEEK Spacers7)
316/316L (1.4401/1.4404) stainless steel probe
and process connection with PEEK HT spacers
dk ≥ 1.48)
316/316L (1.4401/1.4404) stainless steel probe
and process connection with Teflon spacers
dk ≥ 28)9)
Probe Insertion Length
Add order code Y01 and plain text:
"Insertion length ... mm"
Model option 1, 4 and Material of Construction
option A, E: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1, 4 and Material of Construction
option A, E: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1, 4 and Material of Construction
option A, E: 201 ... 300 cm (79.1 ... 118.1 inch)
Model option 1, 4 and Material of Construction
option A, E: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1, 4 and Material of Construction
option A, E: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1, 4 and Material of Construction
option A,E: 501 ... 610 cm (197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
Model options 3, 6 with Material of Construction
option A: 60 ... 100 cm (23.6 ... 39.4 inch)
Model options 3, 6 with Material of Construction
option A: 101 ... 200 cm (39.8 ... 78.7 inch)
Model options 3, 6 with Material of Construction
option A: 201 ... 300 cm (79.1 ... 118.1 inch)
Model options 3, 6 with Material of Construction
option A: 301 ... 400 cm (118.5 ... 157.5 inch)
Model options 3, 6 with Material of Construction
option A: 401 ... 500 cm (157.9 ... 196.9 inch)
Model options 3, 6 with Material of Construction
option A: 501 ... 610 cm (197.2 ... 240.2 inch)
R) 7ML1301SITRANS LG200 Coaxial Probes
SITRANS LG200 coaxial probes are used in most
77 7 7 7 - 777 0
standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric
applications (dK 1.4 ... 100).
Add order code Y01 and plain text:
"Insertion length ... cm"
Model options 3, 6 with Material of Construction
option E: 60 ... 100 cm (23.6 ... 39.4 inch)
Model options 3, 6 with Material of Construction
option E: 101 ... 200 cm (39.8 ... 78.7 inch)
Model options 3, 6 with Material of Construction
option E: 201 ... 300 cm (79.1 ... 118.1 inch)
Note:
In addition to the probe, please select a
transmitter configuration to complete the
SITRANS LG200 (ordered separately).
For orders of 10 or more, please consult factory.
Model
Coaxial1) 2)
Coaxial, High Temperature/High Pressure2)3)
Coaxial, High Pressure2)3)
Order No.
Selection and Ordering data
D
E
H
J
A1
A2
A3
A4
A5
A6
B1
B2
B3
B4
B5
B6
C2
C3
Model options 3, 6 with Material of Construction
option E: 301 ... 400 cm (118.5 ... 157.5 inch)
C4
Model options 3, 6 with Material of Construction
option E: 401 ... 500 cm (157.9 ... 196.9 inch)
Model options 3, 6 with Material of Construction
option E: 501 ... 610 cm (197.2 ... 240.2 inch)
C5
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 2 with Material of Construction
options A, E, H, J: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 2 with Material of Construction
options A, E, H, J: 101 ... 200 cm
(39.8 ... 78.7 inch)
Model option 2 with Material of Construction
options A, E, H, J: 201 ... 300 cm
(79.1 ... 118.1 inch)
A
C1
C6
E1
5
E2
E3
Model option 2 with Material of Construction
options A, E, H, J: 301 ... 400 cm
(118.5 ... 157.5 inch)
Model option 2 with Material of Construction
options A, E, H, J: 401 ... 500 cm
(157.9 ... 196.9 inch)
Model option 2 with Material of Construction
options A, E, H, J: 501 ... 610 cm
(197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
E4
Model option 5 with Material of Construction
options A, D: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 5 with Material of Construction
options A, D: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 5 with Material of Construction
options A, D: 201 ... 300 cm (79.1 ... 118.1 inch)
F1
Model option 5 with Material of Construction
options A, D: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 5 with Material of Construction
options A, D: 401 ... 455 cm (157.9 ... 180 inch)
F4
E5
E6
F2
F3
F5
O-rings
Viton
EPDM (Ethylene Propylene Rubber)
Kalrez 4079
1 1
1 2
1 3
HSN (Nitrile)
Buna-N
Neoprene
1 4
1 5
1 6
Chemraz
Polyurethane
Aegis PF128
1 7
1 8
2 1
Kalrez 2035
None (Borosilicate glass seal,
not for steam applications)10)
2 2
2 3
Siemens FI 01 · 2012
5/279
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
5
Order No.
Selection and Ordering data
Order No.
R) 7ML1301SITRANS LG200 Coaxial Probes
SITRANS LG200 coaxial probes are used in most
77 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric
applications (dK 1.4 ... 100).
R) 7ML1301SITRANS LG200 Coaxial Probes
SITRANS LG200 coaxial probes are used in most
77 7 7 7 - 777 0
standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric
applications (dK 1.4 ... 100).
Process Connection (Size/Type)
Threaded
¾" NPT [(Taper), ANSI/ASME B1.20.1]
G 1" [(BSPP), EN ISO 228-1]
G 2" [(BSPP), EN ISO 228-1]11)
EN flanges
DN 25 PN 16 EN 1092-1
Type A flat faced flange
DN 25 PN 25/40 EN 1092-1
Type A flat faced flange
DN 25 PN 64/100 EN 1092-1
Type B2 raised faced flange
AA
AB
AC
2" NPT [(Taper), ANSI/ASME B1.20.1]1)
ASME flanges
1" 150 lb ASME raised face flange
1" 300 lb ASME raised face flange
1" 600 lb ASME raised face flange
AD
1" 900/1500 lb ASME raised face flange10)
1" 2500 lb ASME raised face flange10)
1" 900/1500 lb ASME ring joint flange10)
BD
BE
BF
1" 2500 lb ASME ring joint flange10)
BG
1½" 150 lb ASME raised face flange
1½" 300 lb ASME raised face flange
CA
CB
1½" 600 lb ASME raised face flange
1½" 900/1500 lb ASME raised face flange10)
1½" 2500 lb ASME raised face flange10)
CC
CD
CE
1½" 600 lb ASME ring joint flange
1½" 900/1500 lb ASME ring joint flange10)
1½" 2500 lb ASME ring joint flange10)
CF
CG
CH
2" 150 lb ASME raised face flange
2" 300 lb ASME raised face flange
2" 600 lb ASME raised face flange
DA
DB
DC
2" 900/1500 lb ASME raised face flange10)
2" 2500 lb ASME raised face flange10)
2" 600 lb ASME ring joint flange
DD
DE
DF
2" 900/1500 lb ASME ring joint flange10)
2" 2500 lb ASME ring joint flange10)
DG
DH
3" 150 lb ASME raised face flange
EA
3" 300 lb ASME raised face flange
3" 600 lb ASME raised face flange
3" 900 lb ASME raised face flange10)
3" 1500 lb ASME raised face flange10)
EB
EC
ED
EE
3" 2500 lb ASME raised face flange10)
3" 600 lb ASME ring joint flange
3" 900 lb ASME ring joint flange10)
EF
EG
EH
3" 1500 lb ASME ring joint flange10)
3" 2500 lb ASME ring joint flange10)
4" 150 lb ASME raised face flange
EJ
EK
FA
4" 300 lb ASME raised face flange
4" 600 lb ASME raised face flange
4" 900 lb ASME raised face flange10)
FB
FC
FD
4" 1500 lb ASME raised face flange10)
4" 2500 lb ASME raised face flange10)
4" 600 lb ASME ring type joint flange
FE
FF
FG
FH
4" 900 lb ASME ring type joint flange10)
4" 1500 lb ASME ring type joint flange10)
4" 2500 lb ASME ring type joint flange10)
5/280
Siemens FI 01 · 2012
BA
BB
BC
FJ
FK
GA
GB
GC
DN 25 PN 160 EN 1092-1
Type B2 raised faced flange10)
DN 25 PN 250 EN 1092-1
Type B2 raised faced flange10)
DN 25 PN 320 EN 1092-1
Type B2 raised faced flange10)
GD
DN 25 PN 400 EN 1092-1
Type B2 raised faced flange10)
DN 40 PN 16 EN 1092-1
Type A flat faced flange
DN 40 PN 25/40 EN 1092-1
Type A flat faced flange
GG
DN 40 PN 64/100 EN 1092-1
Type B2 raised faced flange
DN 40 PN 160 EN 1092-1
Type B2 raised faced flange10)
DN 40 PN 250 EN 1092-1
Type B2 raised faced flange10)
HC
DN 40 PN 320 EN 1092-1
Type B2 raised faced flange10)
DN 40 PN 400 EN 1092-1
Type B2 raised faced flange10)
DN 50 PN 16 EN 1092-1
Type A flat faced flange
HF
DN 50 PN 25/40 EN 1092-1
Type A flat faced flange
JB
DN 50 PN 64 EN 1092-1
Type B2 raised faced flange
DN 50 PN 100 EN 1092-1
Type B2 raised faced flange
JC
DN 50 PN 160 EN 1092-1
Type B2 raised faced flange10)
DN 50 PN 250 EN 1092-1
Type B2 raised faced flange10)
DN 50 PN 320 EN 1092-1
Type B2 raised faced flange10)
JE
DN 50 PN 400 EN 1092-1
Type B2 raised faced flange10)
DN 80 PN 16 EN 1092-1
Type A flat faced flange
DN 80 PN 25/40 EN 1092-1
Type A flat faced flange
JH
GE
GF
HA
HB
HD
HE
HG
JA
JD
JF
JG
KA
KB
DN 80 PN 64 EN 1092-1
Type B2 raised faced flange
DN 80 PN 100 EN 1092-1
Type B2 raised faced flange
DN 80 PN 160 EN 1092-1
Type B2 raised faced flange10)
KC
DN 80 PN 250 EN 1092-1
Type B2 raised faced flange10)
DN 80 PN 320 EN 1092-1
Type B2 raised faced flange10)
DN 80 PN 400 EN 1092-1
Type B2 raised faced flange10)
KF
KD
KE
KG
KH
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
Order code
Selection and Ordering data
R) 7ML1301SITRANS LG200 Coaxial Probes
SITRANS LG200 coaxial probes are used in most
77 7 7 7 - 77 7 0
standard applications. Coaxial probes yield robust
signal strength even in extremely low dielectric
applications (dK 1.4 ... 100).
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Enter the total insertion length in plain text description, max. 610 cm (240.2 inch)
Y01
DN 100 PN 16 EN 1092-1 Type A flat faced flange
DN 100 PN 25/40 EN 1092-1
Type A flat faced flange
DN 100 PN 64 EN 1092-1
Type B2 raised faced flange
LA
LB
Stainless steel tag. Measuring-point number/identification (max. 16 characters); specify in plain text
Y15
LC
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturer’s test report (Hydrostatic Test)
C18
DN 100 PN 100 EN 1092-1
Type B2 raised faced flange
DN 100 PN 160 EN 1092-1
Type B2 raised faced flange10)
DN 100 PN 250 EN 1092-1
Type B2 raised faced flange10)
LD
NACE MR-0175 materials traceability
D07
LE
Operating Instructions
DN 100 PN 320 EN 1092-1
Type B2 raised faced flange10)
DN 100 PN 400 EN 1092-1
Type B2 raised faced flange10)
LG
Fisher torque tube flange, carbon steel (249B)
Fisher torque tube flange, 316 stainless steel (249C)
Masoneilan torque tube flange, carbon steel
MA
MB
MC
Masoneilan torque tube flange, 316 stainless steel
MD
1)
Not available with O-ring option 21 (type Aegis PF128)
Consult factory for these options in Hastelloy C or Monel
3) Available with O-ring option 23 only (none)
4)
Coaxial steam probe must be used with O-ring option 21 only
(type Aegis PF128)
5)
Available with Material of Construction option A and D only
[316/316L (1.4401/1.4404) stainless steel]
6) Available with Model option 5 only (coaxial steam probe)
7)
2" or DN 50 minimum Process Connection and available with PEEK
Spacers for temperature maximum 345 °C (650 °F)
8)
Used with Model option 2 only
(coaxial High Temperature/High Pressure probe)
9) Process temperature maximum 345 °C (650 °F)
10)
Available with model options 2, 3, and 5 only (High Temperature/
High Pressure, High Pressure, and Steam probes only)
11)
Available with Material of Construction option E only
(enlarged coaxial probe)
2)
LF
LH
Order No.
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
Accessories
Coaxial probe shortening kit with TFE end spacer
[for process temperatures < 200 °C (400 °F)]
C) A5E02455728
Coaxial probe TFE end spacer
[for process tempertures < 200 °C (400 °F)]
C) A5E02479158
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
R) Subject to export regulations AL: N, ECCN: EAR991.
R) Subject to export regulations AL: N, ECCN: EAR99I.
Siemens FI 01 · 2012
5/281
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
Selection and Ordering data
R) 7ML1302SITRANS LG200 Twin Rod Probes
SITRANS LG200 twin rod probes are used in appli7 7 7 7 7 - 77 7 0
cations where coating and buildup are possible.
Used in application with dielectric constant ≥1.9.
Model option 1 and Material of Construction
option A: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1 and Material of Construction
option A: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1 and Material of Construction
option A: 501 ... 610 cm (197.2 ... 240.2 inch)
Note:
In addition to the probe, please select a
transmitter configuration to complete the
SITRANS LG200 (ordered separately).
For orders of 10 or more, please consult factory.
Model
Twin rigid rod
Flexible twin rod bulk solids probe1)
Flexible twin rod probe
Material of Construction
316/316L (1.4401/1.4404) stainless steel probe
and process connection
5
Standard lengths3)
Model option 2,3 and Material of Construction
option A: 1 m (39.4 inch)3)
Model option 2,3 and Material of Construction
option A: 2 m (78.7 inch)3)
Model option 2,3 and Material of Construction
option A: 3 m (118.1 inch)3)
1
2
3
A
Process Connection (size/type)
2" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1]
2" 150 lb ASME raised face flange2)
A1
A2
A3
2" 300 lb ASME raised face flange2)
3" 150 lb ASME raised face flange
2" 600 lb ASME raised face flange2)
B1
B2
B3
3" 300 lb ASME raised face flange
4" 150 lb ASME raised face flange
3" 600 lb ASME raised face flange
C1
C2
C3
4" 300 lb ASME raised face flange
DN 50 PN 16 EN 1092-1 Type A flat faced flange
4" 600 lb ASME raised face flange
D1
D2
D3
DN 50 PN 25/40 EN 1092-1
Type A flat faced flange
DN 80 PN 16 EN 1092-1 Type A flat faced flange
DN 80 PN 25/40 EN 1092-1
Type A flat faced flange
E1
DN 100 PN 16 EN 1092-1
Type A flat faced flange
DN 100 PN 25/40 EN 1092-1
Type A flat faced flange
Fisher Torque Tube flange, 316SS (249C)
E4
Masoneilan Torque Tube flange, 316SS
G1
Carbon Steel
Fisher Torque Tube flange, Carbon Steel (249B)
Masoneilan Torque Tube flange, Carbon Steel
E2
E3
E5
F1
K1
L1
O-ring
Viton
EPDM (Ethylene Propylene Rubber)
Kalrez 4079
1 1
1 2
1 3
HSN (Nitrile)
Buna-N
Neoprene
1 4
1 5
1 6
Chemraz
Polyurethane
Aegis PF128
1 7
1 8
2 1
Kalrez 2035
2 2
Probe Insertion Length
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1 and Material of Construction
option A: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1 and Material of Construction
option A: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1 and Material of Construction
option A: 201 ... 300 cm (79.1 ... 118.1 inch)
5/282
Siemens FI 01 · 2012
AF
EA
EB
EC
Model option 2,3 and Material of Construction
option A: 7 m (275.6 inch)3)
Model option 2,3 and Material of Construction
option A: 8 m (315.0 inch)3)
Model option 2,3 and Material of Construction
option A: 9 m (354.3 inch)3)
EG
Model option 2,3 and Material of Construction
option A: 10 m (393.7 inch)3)
Model option 2,3 and Material of Construction
option A: 11 m (433.1 inch)3)
Model option 2,3 and Material of Construction
option A: 12 m (472.4 inch)3)
EK
Model option 2,3 and Material of Construction
option A: 13 m (511.8 inch)3)
Model option 2,3 and Material of Construction
option A: 14 m (551.2 inch)3)
Model option 2,3 and Material of Construction
option A: 15 m (590.6 inch)3)
EN
Model option 2,3 and Material of Construction
option A: 16 m (629.9 inch)3)
Model option 2,3 and Material of Construction
option A: 17 m (669.3 inch)3)
Model option 2,3 and Material of Construction
option A: 18 m (708.7 inch)3)
ER
Model option 2,3 and Material of Construction
option A: 19 m (748.0 inch)3)
EU
Model option 2,3 and Material of Construction
option A: 20 m (787.4 inch)3)
Model option 2,3 and Material of Construction
option A: 21 m (826.8 inch)3)
EV
Model option 2,3 and Material of Construction
option A: 22.5 m (885.8 inch)3)
EX
Available with O-ring option 11 only
Available with model option 1 (Twin rigid rod) only
3)
No Y01 needed in order code
R) Subject to export regulations AL: N, ECCN: EAR99I.
AC
AE
ED
2)
AB
AD
Model option 2,3 and Material of Construction
option A: 4 m (157.5 inch)3)
Model option 2,3 and Material of Construction
option A: 5 m (196.9 inch)3)
Model option 2,3 and Material of Construction
option A: 6 m (236.2 inch)3)
1)
AA
Order No.
R) 7ML1302SITRANS LG200 Twin Rod Probes
SITRANS LG200 twin rod probes are used in appli7 7 7 7 7 - 77 7 0
cations where coating and buildup are possible.
Used in application with dielectric constant ≥1.9.
EE
EF
EH
EJ
EL
EM
EP
EQ
ES
ET
EW
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Enter the total insertion length in plain text
description, max. 610 cm (240.2 inch)
Y01
Stainless steel tag. Measuring-point number/identification (max. 16 characters); specify in plain text
Y15
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturer’s test report (Hydrostatic Test)
C18
NACE MR-0175 materials traceability
D07
Operating Instructions
Order No.
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
5
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/283
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
7 7 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
Material of Construction
316/316L (1.4401/1.4404) stainless steel probe
and process connection
316/316L (1.4401/1.4404) stainless steel sanitary
probe and process connection1)4)
PFA faced-flange and rod insulation,
all PFA wetted parts (316 SS rod)1)5)
5
316 AL6XN stainless steel sanitary probe and
process connection1)6)
PFA rod insulation
(316 SS rod and process connection)
Order No.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
77 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
AL6XN10)
¾" Tri-Clover 16 amp sanitary fitting9)10)
1½" Tri-Clover 16 amp sanitary fitting10)
2" Tri-Clover 16 amp sanitary fitting10)
E0
E1
E2
2½" Tri-Clover 16 amp sanitary fitting10)
3" Tri-Clover 16 amp sanitary fitting10)
4" Tri-Clover 16 amp sanitary fitting10)
E3
F1
G1
PFA Coated 316 stainless steel flange11)
2" 150 lb ASME raised face flange11)
2" 300 lb ASME raised face flange11)
3" 150 lb ASME raised face flange11)
H1
H2
J1
E
3" 300 lb ASME raised face flange11)
4" 150 lb ASME raised face flange11)
4" 300 lb ASME raised face flange11)
J2
K1
K2
F
DN 50, PN 16, EN 1092-1
Type A flat faced flange11)
L1
J
DN 50, PN 25/40, EN 1092-1
Type A flat faced flange11)
L2
DN 80, PN 16, EN 1092-1
Type A flat faced flange11)
L3
DN 80, PN 25/40, EN 1092-1
Type A flat faced flange11)
L4
Note:
In addition to the probe, please select a
transmitter configuration to complete the
SITRANS LG200 (ordered separately).
For orders of 10 or more, please consult factory.
Model
Single rod rigid probe1)
High Temperature/High Pressure Single rod2)3)
Selection and Ordering data
1
2
A
D
Process Connection (size/type)
1 or 1½" Tri-Clover 16 amp sanitary fitting7)
2" NPT [(Taper), ANSI/ASME B1.20.1]8)
G 2" [(BSPP), EN ISO 228-1]8)
A1
A2
A3
2" 150 lb ASME raised face flange8)
2" 300 lb ASME raised face flange8)
A4
A5
DN 100, PN 16, EN 1092-1
Type A flat faced flange11)
L5
2" Tri-Clover 16 amp sanitary fitting7)
A6
A7
B0
B1
DN 100, PN 25/40, EN 1092-1
Type A flat faced flange11)
L6
¾" Tri-Clover 16 amp sanitary fitting7) 9)
2½" Tri-Clover 16 amp sanitary fitting7)
3" 150 lb ASME raised face flange8)
3" 300 lb ASME raised face flange8)
3" Tri-Clover 16 amp sanitary fitting7)
4" 150 lb ASME raised face flange8)
B2
B3
C1
4" 300 lb ASME raised face flange8)
4" Tri-Clover 16 amp sanitary fitting7)
C2
C3
DN 50, PN 16, EN 1092-1
Type A flat faced flange8)
D1
DN 50, PN 25/40, EN 1092-1
Type A flat faced flange8)
D2
DN 80, PN 16, EN 1092-1
Type A flat faced flange8)
D3
DN 80, PN 25/40, EN 1092-1
Type A flat faced flange8)
D4
DN 100, PN 16, EN 1092-1
Type A flat faced flange8)
D5
DN 100, PN 25/40, EN 1092-1
Type A flat faced flange8)
D6
5/284
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
7 7 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
77 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
Higher Pressure rated flanges
EN flanges
DN 50, PN 64, EN 1092-1
Type B2 raised faced flange8)
DN 50, PN 100, EN 1092-1
Type B2 raised faced flange8)
DN 50, PN 160, EN 1092-1
Type B2 raised faced flange12)
ANSI/ASME
flange8)
2" 600 lb ASME raised face
2" 900/1500 lb ASME raised face flange12)
2" 2500 lb ASME raised face flange12)
M0
M1
M2
3" 600 lb ASME raised face flange8)
3" 900 lb ASME raised face flange12)
3" 1500 lb ASME raised face flange12)
N0
N3
N4
3" 2500 lb ASME raised face flange12)
4" 600 lb ASME raised face flange8)
4" 900 lb ASME raised face flange12)
N5
P0
P3
4" 1500 lb ASME raised face flange12)
4" 2500 lb ASME raised face flange12)
2" 600 lb ASME ring type joint flange8)
P4
P5
Q0
2" 900/1500 lb ASME ring type joint flange12)
2" 2500 lb ASME ring type joint flange12)
3" 600 lb ASME ring type joint flange8)
Q1
Q2
R0
3" 900 lb ASME ring type joint flange12)
3" 1500 lb ASME ring type joint flange12)
3" 2500 lb ASME ring type joint flange12)
R3
R4
R5
4" 600 lb ASME ring type joint flange8)
4" 900 lb ASME ring type joint flange12)
4" 1500 lb ASME ring type joint flange12)
S0
S3
S4
4" 2500 lb ASME ring type joint flange12)
S5
DN 50, PN 250, EN 1092-1
Type B2 raised faced flange12)
DN 80, PN 64, EN 1092-1
Type B2 raised faced flange8)
DN 80, PN 100, EN 1092-1
Type B2 raised faced flange8)
T0
T1
T2
T3
U0
U1
DN 80, PN 160, EN 1092-1
Type B2 raised faced flange12)
DN 80, PN 250, EN 1092-1
Type B2 raised faced flange12)
DN 100, PN 64, EN 1092-1
Type B2 raised faced flange8)
U2
DN 100, PN 100, EN 1092-1
Type B2 raised faced lange8)
DN 100, PN 160, EN 1092-1
Type B2 raised faced flange12)
DN 100, PN 250, EN 1092-1
Type B2 raised faced flange12)
V1
U3
5
V0
V2
V3
Siemens FI 01 · 2012
5/285
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
5
Order No.
Selection and Ordering data
Order No.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
7 7 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
R) 7ML1303SITRANS LG200 Single Rod Rigid Probes
SITRANS LG200 single rod rigid probes are used in
77 7 7 7 - 777 0
applications where coating and buildup are likely.
Used in applications with dielectric constant ≥10, or
dk >1.9 when installed within 2 ... 6" of a metal tank
wall or in cage or bridle.
O-ring
Viton
EPDM (Ethylene Propylene Rubber)
Kalrez 4079
1 1
1 2
1 3
HSN (Nitrile)
Buna-N
Neoprene
1 4
1 5
1 6
Model option 1 and Material of Construction
option E: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1 and Material of Construction
option E: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1 and Material of Construction
option E: 501 ... 610 cm (197.2 ... 240.2 inch)
Chemraz
Polyurethane
Aegis PF128
1 7
1 8
2 1
Kalrez 2035
None
2 2
2 3
Probe Insertion Length
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1, 2 and Material of Construction
option A: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1, 2 and Material of Construction
option A: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1, 2 and Material of Construction
option A: 201 ... 300 cm (79.1 ... 118.1 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1 and Material of Construction
option J: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1 and Material of Construction
option J: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1 and Material of Construction
option J: 201 ... 300 cm (79.1 ... 118.1 inch)
AA
AB
AC
Model option 1, 2 and Material of Construction
option A: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1, 2 and Material of Construction
option A: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1, 2 and Material of Construction
option A: 501 ... 610 cm (197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1 and Material of Construction
option D: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1 and Material of Construction
option D: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1 and Material of Construction
option D: 201 ... 300 cm (79.1 ... 118.1 inch)
AD
Model option 1 and Material of Construction
option D: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1 and Material of Construction
option D: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1 and Material of Construction
option D: 501 ... 610 cm (197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1 and Material of Construction
option F: 60 ... 100 cm (23.6 ... 39.4 inch)
Model option 1 and Material of Construction
option F: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1 and Material of Construction
option F: 201 ... 300 cm (79.1 ... 118.1 inch)
BD
Model option 1 and Material of Construction
option F: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1 and Material of Construction
option F: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1 and Material of Construction
option F: 501 ... 610 cm (197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm"
Model option 1 and Material of Construction
option E: 60 ... 100 cm (23.6 ... 39.4 inch)
CD
Model option 1 and Material of Construction
option E: 101 ... 200 cm (39.8 ... 78.7 inch)
Model option 1 and Material of Construction
option E: 201 ... 300 cm (79.1 ... 118.1 inch)
DB
5/286
Siemens FI 01 · 2012
AE
AF
BA
BB
BC
BE
BF
Model option 1 and Material of Construction
option J: 301 ... 400 cm (118.5 ... 157.5 inch)
Model option 1 and Material of Construction
option J: 401 ... 500 cm (157.9 ... 196.9 inch)
Model option 1 and Material of Construction
option J: 501 ... 610 cm (197.2 ... 240.2 inch)
Add order code Y01 and plain text:
"Insertion length ... cm""
(¾" Process Connection only)
Model option 1 and Material of Construction
option D and F: 60 ... 100 cm (23.6 ... 39.4 inch)13)
Model option 1 and Material of Construction
option D and F: 101 ... 180 cm (39.8 ... 72 inch)13)
1)
CB
CC
CE
CF
DA
DC
DE
DF
EA
EB
EC
ED
EE
EF
FA
FB
Model option 1 with Material of Construction options D, E, F,
available with O-ring option 23 only
2)
Available with O-ring option 21 only
3)
Available with Material of Construction option A only
4) Available with Process Connection options A1, A6, A7, B0, B3, C3 only
5)
Available with Process Connection options H1, H2, J1, J2, K1, K2, L1, L2,
L3, L4, L5, L6 only.
6)
Available with Process Connection options E0, E1, E2, E3, F1, G1 only
7) Available with Material of Construction option D only
8)
Available with Material of Construction options A and J only
9)
Available with Probe Insertion Length options FA and FB only
10) Available with Material of Construction option F only
11)
Available with Material of Construction option E only
12)
Available with Model option 2 only
13) Available with Process Connection options A7 and E0 only (¾”)
R) Subject to export regulations AL: N, ECCN: EAR99I.
CA
DD
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Enter the total insertion length in plain text description, max. 610 cm (240.2 inch)
Y01
Stainless steel tag. Measuring-point number/identification (max. 16 characters); specify in plain text
Y15
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturer’s test report (Hydrostatic Test)
C18
NACE MR-0175 materials traceability
D07
Order No.
Operating Instructions
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
TFE bottom spacer/endplate
5
R) 7ML1930-1DJ
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
R) Subject to export regulations AL: N, ECCN: EAR99I.
Siemens FI 01 · 2012
5/287
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Selection and Ordering data
Order No.
R) 7ML1304SITRANS LG200 Single Rod Flexible Probes
SITRANS LG200 single rod flexible probes are
7 7 7 7 7 - 777 0
used in applications where coating and buildup are
possible. Used in applications with dielectric constant ≥10 or dk >1.9 when installed within 2 ... 6" of a
metal tank wall or in cage or bridle. For solids version only, dk>4.
Note:
In addition to the probe, please select a
transmitter configuration to complete the
SITRANS LG200 (ordered separately).
For orders of 10 or more, please consult factory.
Model
Single rod flexible probe
Single rod bulk solids flexible probe1)
Material of Construction
316/316L (1.4401/1.4404) stainless steel probe and
process connection
5
1
2
A
Selection and Ordering data
Order No.
R) 7ML1304SITRANS LG200 Single Rod Flexible Probes
SITRANS LG200 single rod flexible probes are
77 7 7 7 - 777 0
used in applications where coating and buildup are
possible. Used in applications with dielectric constant ≥10 or dk >1.9 when installed within 2 ... 6" of a
metal tank wall or in cage or bridle. For solids version only, dk>4.
Flexible Rod Length
(To be shortened by customer as required)
1 meter (39.4 inch)
2 meters (78.7 inch)
3 meters (118.1 inch)
AA
AB
AC
4 meters (157.5 inch)
5 meters (196.9 inch)
6 meters (236.2 inch)
AD
AE
AF
7 meters (275.6 inch)
8 meters (315.0)
9 meters (354.3 inch)
AG
AH
AJ
10 meters (393.7 inch)
11 meters (433.1 inch)
12 meters (472.4 inch)
AK
AL
AM
13 meters (511.8 inch)
14 meters (551.2 inch)
15 meters (590.6 inch)
AN
AP
AQ
16 meters (629.9 inch)
17 meters (669.3 inch)
AR
AS
Process Connection (size/type)
316/316L (1.4401/1.4404)
2" NPT [(Taper), ANSI/ASME B1.20.1]
G 2" [(BSPP), EN ISO 228-1]
2" 150 lb ASME raised face flange
A0
A1
A2
2" 300 lb ASME raised face flange
3" 150 lb ASME raised face flange
3" 300 lb ASME raised face flange
A3
B1
B2
4" 150 lb ASME raised face flange
4" 300 lb ASME raised face flange
DN 50 PN 16 EN 1092-1 Type A flat faced flange
C1
C2
D1
18 meters (708.7 inch)
19 meters (748.0 inch)
AT
AU
20 meters (787.4 inch)
AV
DN 50 PN 25/40 EN 1092-1 Type A flat faced flange
DN 80 PN 16 EN 1092-1 Type A flat faced flange
DN 80 PN 25/40 EN 1092-1 Type A flat faced flange
D2
E1
E2
21 meters (826.8 inch)
22.5 meters (885.8 inch)
AW
AX
DN 100 PN 16 EN 1092-1 Type A flat faced flange
DN 100 PN 25/40 EN 1092-1 Type A flat faced
flange
F1
F2
1)
Available with O-ring option 1 1 only (others on request)
R) Subject to export regulations AL: N, ECCN: EAR99.
O-ring
Viton
EPDM (Ethylene Propylene Rubber)
Kalrez 4079
1 1
1 2
1 3
HSN (Nitrile)
Buna-N
Neoprene
1 4
1 5
1 6
Chemraz
Polyurethane
Aegis PF128
1 7
1 8
2 1
Kalrez 2035
2 2
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag. Measuring-point number/identification (max. 16 characters); specify in plain text
Operating Instructions
Y15
Order No.
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/288
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Order No.
SITRANS LG200 Chamber Replacement Probe R) 7ML1305Replaces existing aging torque tube transmitters.
7 7 7 7 7 - 777 0
Proprietary flanges can be used with existing
chambers and cages.
Selection and Ordering data
Note:
In addition to the probe, please select a
transmitter configuration to complete the
SITRANS LG200 (ordered separately).
For this option, please consult factory
Model
Chamber Replacement Probe1)
Chamber/Process Connection Material of
Construction
316/316L stainless steel (B31.1 construction)
Carbon Steel (106 Grade B)2)
Carbon Steel (B31.1 construction)
1
1½", 600 lb ASME raised face flange
1½" Socket weld
2" NPT [(Taper), ANSI/ASME B1.20.1] thread
A3
B1
B2
2", 150 lb ASME raised face flange
2", 300 lb ASME raised face flange
2", 600 lb ASME raised face flange
C1
C2
D1
2" Socket weld
Other flange sizes available. Please consult factory.
D2
Temperature Range
316 °C (600 °F) (Dielectric constant ≥ 10)
260 °C (500 °F) (Dielectric constant ≥ 1.4)
Chamber Type
Fisher 249B
Fisher 259B
Fisher 249
Please add "-Z" to Order No. and specify Order
code(s).
Stainless steel tag. Measuring-point number/identification (max. 16 characters); specify in plain text
Y15
Inspection Certificate Type 3.1 per EN 10204
C12
NACE MR-0175 materials traceability
D07
Order No.
English
C) 7ML1998-5KA02
French
C) 7ML1998-5KA11
German
C) 7ML1998-5KA32
C) 7ML1998-5XG81
Multi-language Quick Start manual
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
A
B
C
A0
A1
A2
Process Connection Configuration
Top In, Bottom Out
Top In, Bottom Out, with Sight Glass Connections
Other configurations available. Please consult
factory.
Further designs
Operating Instructions
Process Connection (size/type)
1½" NPT [(Taper), ANSI/ASME B1.20.1] thread
1½", 150 lb ASME raised face flange
1½", 300 lb ASME raised face flange
Level Range
14" (0.356 meters)
Other level ranges available. Please consult factory.
Order code
Selection and Ordering data
Accessories
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
1
1
2
A
B
A
B
C
1)
Probe is always 316/316L (1.4401/1.4404) Stainless Steel construction
regardless of chamber and process connection materials.
Available Process Connection Configuration option 1 only
R) Subject to export regulations AL: N, ECCN: EAR99I.
2)
Siemens FI 01 · 2012
5/289
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Ambient Temperature
■ Characteristic curves
93 °C
(200 °F)
82 °C
(180 °F)
71 °C
(160 °F)
60 °C
(140 °F)
49 °C
(120 °F)
38 °C
(100 °F)
27 °C
(80 °F)
16 °C
(60 °F)
4 °C
(40 °F)
5
-6 °C
(20 °F)
-17 °
(0 °F)
38 °C
(100 °F)
66 °C
(150 °F)
93 °C
(200 °F)
121 °C
(250 °F)
Process Pressure
Ambient Temperature vs Process Temperature
7ML1301-1, 1302-1, 1303-1, 1302-3
149 °C
(300 °F)
177 °C
(350 °F)
204 °C
(400 °F)
Process Temperature
83 bar g (1200 psi g)
76 bar g (1100 psi g)
69 bar g (1000 psi g)
62 bar g (900 psi g)
55 bar g (800 psi g)
48 bar g (700 psi g)
41 bar g (600 psi g)
35 bar g (500 psi g)
28 bar g (400 psi g)
21 bar g (300 psi g)
14 bar g (200 psi g)
7 bar g (100 psi g)
0 bar g (0 psi g)
10 °C
(50 °F)
66 °C
(150 °F)
121 °C
(250 °F)
Process Temperature [max. +204°C (+400°F)]
7ML1304-1, 1301-1, 1303-1,
7ML1302-3, 1302-1, 1301-4, 1301-6
SITRANS LG200 Process Pressure/Temperature derating curves
5/290
Siemens FI 01 · 2012
177 °C
(350 °F)
232 °C
(450 °F)
Process Temperature
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
Process pressure
241 bar g
(3500 psi g)
207 bar g
(3000 psi g)
172 bar g
(2500 psi g)
138 bar g
(2000 psi g)
103 bar g
(1500 psi g)
69 bar g
(1000 psi g)
34 bar g
(500 psi g)
0 bar g
(0 psi g)
-17 °C
(0 °F)
5
93 °C
(200 °F)
7ML1301-5 [max. +343 °C (+650 °F)]
204 °C
(400 °F)
316 °C
(600 °F)
427 °C
(800 °F)
Process Temperature
7ML1303-2 [max. +318 °C (+605 °F)]
Process pressure
448 bar g (6500 psi g)
413 bar g (6000 psi g)
379 bar g (5500 psi g)
345 bar g (5000 psi g)
310 bar g (4500 psi g)
276 bar g (4000 psi g)
241 bar g (3500 psi g)
207 bar g (3000 psi g)
172 bar g (2500 psi g)
138 bar g (2000 psi g)
103 bar g (1500 psi g)
69 bar g (1000 psi g)
34 bar g (500 psi g)
0 bar g (0 psi g)
-196 °C -129 °C -73 °C -17 °C 38 °C
93 °C 149 °C 204 °C 260 °C 316 °C 371 °C 427 °C
(-320 °F) (-200 °F) (-100 °F) (0 °F) (100°F) (200 °F) (300 °F) (400 °F) (500 °F) (600 °F) (700 °F) (800 °F)
7ML1301-3 [max. +204 °C (+400 °F)]
Process Temperature
7ML1301-2 [max. +427 °C (+800 °F)]
SITRANS LG200 Process Pressure/Temperature derating curves
Siemens FI 01 · 2012
5/291
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
■ Dimensional drawings
SITRANS LG200 Enclosure 7ML1300
7ML1301-1 (7xA-x) Probe, Threaded and Flanged Connection
enclosure
lid with
window
59 (2.32)
14.0 (0.55)
M20: 135 (5.32)
½" NPT: 150 (5.91)
74 (2.91)
145 (5.7)
120 (4.7)
2 cable
entries
½" NPT or
M20x1.5
38 (1 1/2)
22 or 45 mm
(dependant on option)
process
connection
22 or 45 mm
(dependant on option)
probe insertion
length
optional
spacer
60
(2.36)
60 (2.36)
7ML1303-1D (7xF-E) Probe, Sanitary Connection
12 (0.5) dia. rod
D
12 (0.5) dia. rod
probe insertion length
probe insertion
length
B
A
14.0 (0.55)
57 (2.24)
7ML1303-1 (7xF-x) Probe, Threaded and Flanged Connection
probe insertion
length
D
process
connection
optional
spacer
12 (0.5) dia. rod
C
5
probe insertion
length
B
A
166 (6.54)
153 (6.02)
lid without
window
Probe Connections and Insertion Lengths (Note BSP connections differ from NPT)
22 or 45 mm
(dependant on option)
ANSI or DIN welded flange
insertion length
insertion length
C
B
insertion length
insertion length
A
22 or 45 mm
(dependant on option)
sanitary flange
22 or 45 mm
(dependant on option)
D
BSP
NPT
22 or 45 mm
(dependant on option)
SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise), dimensions in mm (inch)
5/292
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
SITRANS LG200
7ML1304-1 (7x1-x) Flexible Probe,
Threaded or Flanged Connection
44 (1.75)
76 (3)
5 (0.1875)
dia. cable
5
19 (0.75)
32 (1.25)
57 (2.25)
99 (3.88)
12 (0.5)
dia. hole
14
(0.56)
83 (3.25)
7ML1304-2 (7x2-x) Bulk Solids Flexible Probe,
Threaded or Flanged Connection
80 (3.13)
mounting
flange
probe insertion
length
D
6 (0.25)
dia. cable
threaded
process
connection
probe insertion
length
B
A
76 (3)
60 (2.36)
FEP
webbing
50 (2) dia.
50 (2) dia.
19 (0.75)
99 (3.88)
25 (1)
57 (2.25)
16 (0.625)
with PFA
lining
TFE
spacer
284 g (10 oz)
TFE weight
284 g (10 oz)
TFE weight
12 (0.5)
dia. hole
probe insertion
length
D
12 (0.5)
rod diameter
probe insertion
length
B
A
FEP
webbing
mounting
flange
71 (2.80)
20.3
(0.8)
76 (3)
probe insertion
length
D
TFE
spacer
450 g (1 lb)
TFE weight
7ML1303-1E (7xF - F) Probe,
Flat-Faced Flanged Connection
threaded
process
connection
probe insertion
length
D
60 (2.36)
57 (2.24)
probe insertion
length
B
A
610 (24)
14
(0.56)
mounting
threaded
flange
process
connection
5 (0.1875)
dia. cable
450 g (1 lb)
TFE weight
7ML1302-3 (7x7-x) Twin Rod Flexible Probe,
Threaded or Flanged Connection
2.25 kg (5 lb)
AISI 316 weight
152 (6.00)
2.25 kg (5 lb)
AISI 316 weight
50 (2) dia.
SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise), dimensions in mm (inch)
Siemens FI 01 · 2012
5/293
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
SITRANS LG200
7ML1302-1 (7xB-x) Twin Rod Probe,
Threaded and Flanged Connection
FEP
webbing
5 (0.1875)
dia. cable
probe insertion
length
D
TFE
spacer
2.25 kg (5 lb)
AISI 316 weight
2.25 kg (5 lb)
AISI 316 weight
22,2 (0.875)
mounting
flange
76 (3)
80 (3.13)
probe insertion
length
B
A
probe insertion
length
D
TFE
spacer
FEP
webbing
152 (6)
Twin rod end view
Ø13 (0.50) rods
50 (2) dia.
6,3 (0.248)
7ML1301-2 (7xD-x), 7ML1301-3 (7xP-x), 7ML1301-4 (7xR-x),
7ML1301-6 (7xT-x), Threaded or Flanged Connection
120 (4.7)
120 (4.7)
probe insertion
length
B
A
process
connection
'X'
145 (5.7)
enclosure
process
connection
‘X’ Dimension
(NPT)
‘X’ Dimension
(Flanged)
7ML1301-2
(Coaxial HT/HP Probe)
217 (8.55)
277 (10.91)
7ML1301-3
(Coaxial HP Probe)
106 (4.18)
166 (6.54)
7ML1301-4
(Coaxial Overfill/
Flooded Cage Probe),
7ML1301-6
(Coaxial Interface Probe)
150 (5.89)
167 (6.57)
7ML1301-5
(Coaxial HT/
HP Steam Probe)
180 (7.10)
242 (9.52)
probe insertion
length
D
enclosure
'X'
145 (5.7)
Probes
14 (0.56)
5
TFE
spacer
76 (3)
126
(4.96)
probe insertion
length
B
A
mounting
flange
TFE
spacer
threaded
process
connection
20.3
(0.8)
20.3
(0.8)
threaded
process
connection
83 (3.25)
129 (5.08)
7ML1302-2 (7x5-x) Twin Rod Bulk Solids Flexible Probe
Threaded or Flanged Connection
SITRANS LG200 dimensions (threaded process connection dimensions shown are NPT connections unless stated otherwise), dimensions in mm (inch)
5/294
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
A
min. 156 (6.1)
A
100 %
100 %
3/4" NPT (optional sight
glass connections)
Midrange
B
A
Midrange
Midrange
max. level range
min. 356 (14)
maz. 6100 (240)
0%
0%
min. 76 (3)
B
min. 1½": 64 (2.5)
min. 2": 86 (3.4)
100 %
max. level range
min. 356 (14)
maz. 6100 (240)
min. 76 (3)
5
min. 94 (3.7)
A
100 %
Midrange
max. level range
min. 356 (14)
maz. 6100 (240)
0%
0%
B
min. 1½": 102 (4.1)
min. 2": 110 (43)
min. 76 (3)
B
min. 76 (3)
SITRANS LG200 - Model 7ML1305-1 Chamber Replacement Probe, dimensions in mm (inch)
Siemens FI 01 · 2012
5/295
© Siemens AG 2011
Level Measurement
Continuous level measurement — Guided wave radar transmitters
SITRANS LG200
■ Schematics
SITRANS LG200 General Purpose Wiring
5
Intrinsically Safe wiring
When connecting SITRANS LG200 in Intrinsically Safe applications,
install an approved IS barrier in the non-hazardous (safe) area.
Explosion Proof wiring
When connecting SITRANS LG200 in hazardous areas with explosion
hazard, the wiring for the transmitter must be contained in Explosion
Proof conduit extending into the safe area. An Explosion Proof
conduit fitting is not required within 457 mm (18") of the transmitter.
An Explosion Proof conduit fitting is required between the hazardous
and safe areas.
SITRANS LG200 connections
5/296
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
■ Overview
■ Configuration
Installation
Build up of material in active shield
area does not affect switch
operation.
Mounting on a bypass
SITRANS LC300 is an inverse frequency shift capacitance continuous level transmitter for liquids and solids applications. It is
ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage, water, wastewater, and
mining, aggregate, and cement industries.
5
.5
0
)
(2
■ Application
in
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• Highly accurate and reliable PFA-lined probes
• Integrated local LCD display
• 2-wire (4 to 20 mA) current loop design
• Current signalling according to NAMUR NE 43
• Push-button calibration and programming
• Stilling well (ground tube) version for low dielectric media and
non-metallic vessels
m
■ Benefits
min. 50 (2)
Install probe at least 50 (2) from tank wall.
Note angle of repose and adjust accordingly.
SITRANS LC300 installation, dimensions in mm (inch)
SITRANS LC300 is a 2-wire level measurement instrument
combining a sophisticated, yet easy-to-adjust microprocessor
with field-proven probes. It is available in four versions: rod,
rod with stilling well, cable with PFA insulation, and cable without
PFA insulation.
Materials with low or high dielectric properties are accurately
measured and patented Active-Shield technology helps in
ignoring the effects of buildup or condensation near vessel
nozzle.
• Key Applications: Conductive and non-conductive media including: liquids and solids in standard industrial processes,
bulk solids applications involving dust, and chemical processes involving vapour
Siemens FI 01 · 2012
5/297
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
■ Technical specifications
Input
Safety
Measuring range
1.66 … 3300 pF
Span
Min. 3.3 pF
Output
Measurement current signalling
Certificates and approvals
Loop current
Continuous signal 4 … 20 mA/
20 … 4 mA acc. to NAMUR 43
Accuracy (transmitter)
Temperature stability
0.25% of actual capacitance
value
Non-linearity and repeatability
< 0.4% of full scale and actual
measurement value
Accuracy
Deviation < 0.5% of actual
measurement value
General
CE, CSAUS/C, FM, C-TICK
Dust Ignition Proof
(Intrinsically Safe probe circuit)
(Europe)
ATEX 1/2 D T100 °C
(US/Canada)
FM/CSA:
Class II, Div. 1, Groups E,F,G
Class III T4
Flame Proof
(Intrinsically Safe probe circuit)
(Europe)
ATEX II 1/2 G EEx d [ia] IIC
T6...T1
ATEX II 1/2 D T100 °C
Explosion Proof
(Intrinsically Safe probe circuit)
(US/Canada)
Class I, Div. 1, Groups A,B,C,D
Class II, Div. 1, Groups E,F,G
Class III T4
Marine
Bureau Veritas Type Approval
ABS Type Approval
Overfill Protection
AIB-Vincotte
Other
Pattern Approval (China)
Rated operating conditions1)
Ambient conditions
5
According to NAMUR NE 43,
signal 3.8 … 20.5 mA, fault ≤ 3.6
or ≥ 21 mA (22 mA)
• Ambient temperature
-40 … +85 °C (-40 … +185 °F)2)
• Installation category
I
• Pollution degree
4
• Ingress protection
Type 4/NEMA 4/IP65
(optional IP68)
Installation conditions
• Location
Indoor/outdoor
Process pressure
-1 … +35 bar g
(-14.6 … +511 psi g)
Process temperature
-40 … +200 ºC (-40 … +392 ºF)3)
Min. dielectric constant εr
1.5
Design
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves
on page 5/306.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F)
3) Not suitable for steam environments
Design: Probe
Rod version
Stilling well
version
Cable version
Length
Min. 300 mm
(12 inch),
max. 5000 mm
(197 inch)
Min. 300 mm
(12 inch),
max. 5000 mm
(197 inch)
Min. 1000 mm
(40 inch),
max. 25000 mm
(984 inch)
Sensor wetted
parts
PFA, 316L
stainless steel
PFA, 316L
stainless steel
316L stainless
steel or 316L
stainle7ss steel
with PFA
insulation
O-ring seal
material
FKM or FFKM
FKM or FFKM
FKM or FFKM
Thermal isolator Optional
Optional
Optional
Options
N/A
Mounting eye for
PFA insulated
cable version
Material
• Enclosure
Aluminum, epoxy-coated
Probe diameter
• Rod version
19 mm (0.75 inch) with PFA jacket
• Cable version
9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA jacket
Active shield length
• Rod version
threaded: 120 mm (4.72 inch)
flanged: 100 mm (3.94 inch)
• Cable version
threaded: 125 mm (4.92 inch)
flanged: 105 mm (4.13 inch)
Process connection of probe
• Threaded rod mounting
¾",1",1¼", 1½" NPT [(Taper),
ANSI/ASME B1.20.1]
R ¾",1", 1½" [(BSPT),
EN 10226/PT (JIS-T), JIS B 0203]
G ¾",1", 1½" [(BSPP),
EN ISO 228-1/PF (JIS-P),
JIS B 0202]
• Threaded cable mounting
• Flange mounting
1½" NPT
[(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT
(JIS-T), JIS B 0203]
G 1½"
[(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
1 … 4" ASME, DN 25 … 100
Enclosure cable inlet
2 x ½" NPT or 2 x M20x1.5
Power supply
12 … 30 V DC any polarity, 2-wire
current loop circuit
User Interface
Display
5/298
Local LCD, 4 digit, each 0 … 9
and limited alpha characters
Siemens FI 01 · 2012
N/A
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order No.
Order No.
Selection and Ordering data
C) 7ML5670SITRANS LC300, rod version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 0
level transmitter for liquids and solids applications.
C) 7ML5670SITRANS LC300, rod version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 0
level transmitter for liquids and solids applications.
Process connection
Threaded, 316L stainless steel
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
0A
0B
0C
0D
Wetted seals
FKM
FFKM [for process temperatures above -20 °C
(-4 °F)]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1A
1B
1D
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
1" ASME, 150 lb
1" ASME, 300 lb
1" ASME, 600 lb
3A
3B
3D
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
Probe material
19 mm (0.75 inch) diameter 316L stainless steel,
PFA lined rod
Approvals
General Safety (CSA, FM, CE, C-TICK)
Dust Ignition Proof With IS Probe
CE, C-TICK, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, C-TICK, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
5A
5B
5C
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel, Type A flat
faced1)
DN 25, PN 16
DN 25, PN 40
DN 40, PN 16
5N
5P
5Q
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
6D
6E
6F
DN 80, PN 16
DN 80, PN 40
DN 100, PN 16
DN 100, PN 40
6G
6H
6J
6K
0
A
B
C
D
E
5
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
A
B
C
D
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
1)
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
6A
6B
6C
Probe Length
(from flange face or including process thread)
Add order code Y01 and plain text:
"Insertion length ... mm"
300 ... 1000 mm (11.81 ... 39.37 inch)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)
A
B
C
3001 ... 4000 mm (118.15 ... 157.48 inch)
4001 ... 5000 mm (157.52 ... 196.85 inch)
D
E
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection temperatures over +85 °C (+185 °F)]
0
1
0
1
Siemens FI 01 · 2012
5/299
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
English
French
5
Order No.
C) 7ML1998-5HE03
7ML1998-5HE11
German
C) 7ML1998-5HE33
Spanish
7ML1998-5HE21
C) 7ML1998-5QH81
Multi-language Quick Start manual
Note: The Operating Instructions should be ordered
as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Electronic transmitter kit (includes transmitter and C) 7ML1830-1KN
driver)
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
5/300
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order No.
Selection and Ordering data
Order No.
SITRANS LC300, stilling well version
An inverse frequency shift capacitance continuous
level transmitter for liquid applications.
7ML5671-
7ML5671-
7 7 7 77 - 77 7 0
SITRANS LC300, stilling well version
An inverse frequency shift capacitance continuous
level transmitter for liquid applications.
0D
1D
3D
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel, Type A flat
faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
1)
7 7 7 77 - 77 7 0
A
B
C
D
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
6C
6D
6E
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
Operating Instructions
DN 100, PN 16
DN 100, PN 40
6J
6K
3001 ... 4000 mm (118.15 ... 157.48 inch)
4001 ... 5000 mm (157.52 ... 196.85 inch)
D
E
Wetted seals
FKM
FFKM [for process temperatures above -20 °C
(-4 °F)]
Probe material
35 mm (1.38 inch) diameter stilling well, with
19 mm (0.75 inch) diameter 316L stainless steel,
PFA lined rod with PTFE spacers
Approvals
General Safety (CSA, FM, CE, C-TICK)
Dust Ignition Proof With IS Probe
CE, C-TICK, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, C-TICK, ATEX II 1/2 G EEx d [ia] IIC T6 ... T1,
ATEX II 1/2 D T100 °C
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
C) 7ML1998-5HE03
French
A
B
C
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection temperatures over +85 °C (+185 °F)]
Order No.
English
Probe Length
(from flange face or including
process thread)
Add order code Y01 and plain text:
"Insertion length ... mm"
300 ... 1000 mm (11.81 ... 39.37 inch)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)
5
7ML1998-5HE11
German
C) 7ML1998-5HE33
Spanish
7ML1998-5HE21
C) 7ML1998-5QH81
Multi-language Quick Start manual
Note: The Operating Instructions should be ordered
as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Electronic transmitter kit
(includes transmitter and driver)
C) 7ML1830-1KN
SITRANS RD100 Remote display - see Chapter 8
0
1
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
0
1
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
1
A
B
C
D
E
Siemens FI 01 · 2012
5/301
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
5
Order No.
Selection and Ordering data
Order No.
C) 7ML5672SITRANS LC300, cable version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 0
level transmitter for non-conductive liquids and
solids applications.
C) 7ML5672SITRANS LC300, cable version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 0
level transmitter for non-conductive liquids and
solids applications.
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
Welded flange, 316L stainless steel, raised face1)
0D
1D
3D
Approvals
General Safety (CSA, FM, CE, C-TICK)
Dust Ignition Proof With IS Probe
CE, C-TICK, ATEX II 1/2 D T100 °C
Flame Proof Enclosure With IS Probe
CE, C-TICK, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel, Type A flat
faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
6J
6K
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
6C
6D
6E
1)
2)
Probe Length
(from flange face or including
process thread)
Add order code Y01 and plain text:
"Insertion length ... mm"
1000 ... 2000 mm (39.37 ... 78.74 inch)
2001 ... 4000 mm (78.78 ... 157.48 inch)
4001 ... 6000 mm (157.52 ... 236.22 inch)
A
B
C
6001 ... 8000 mm (236.26 ... 314.96 inch)
8001 ... 10000 mm (315.00 ... 393.70 inch)
10001 ... 12000 mm (393.74 ... 472.44 inch)
D
E
F
12001 ... 14000 mm (472.48 ... 551.18 inch)
14001 ... 16000 mm (551.22 ... 629.92 inch)2)
16001 ... 18000 mm (629.96 ... 708.66 inch)2)
G
H
J
18001 ... 20000 mm (708.70 ... 787.40 inch)2)
20001 ... 22000 mm (787.44 ... 866.14 inch)2)
22001 ... 24000 mm (866.18 ... 944.88 inch)2)
K
L
M
24001 ... 25000 mm (944.92 ... 984.25 inch)2)
N
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection temperatures over +85 °C (+185 °F)]
Wetted seals
FKM
FFKM [for process temperatures above
-20 °C (-4 °F)]
Probe material
Bare 316L stainless steel cable and 316L stainless
steel cable weight, tinned copper crimp, PTFE
backing ring, PEEK isolator and PFA lined active
shield
5/302
Siemens FI 01 · 2012
0
1
0
1
0
A
B
C
D
E
A
B
C
D
Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5 or EN 1092-1 standard.
Cable lengths from 15 000 (590.55 inch) to 25 000 mm (984.25 inch) can
be used in non-conductive media. Contact Factory for assistance.
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
English
French
Order No.
C) 7ML1998-5HE03
7ML1998-5HE11
German
C) 7ML1998-5HE33
Spanish
7ML1998-5HE21
C) 7ML1998-5QH81
Multi-language Quick Start manual
Note: The Operating Instructions should be ordered
as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
5
Accessories
Electronic transmitter kit (includes transmitter
and driver)
C) 7ML1830-1KN
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/303
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
5
Order No.
Selection and Ordering data
Order No.
C) 7ML5673SITRANS LC300, PFA coated cable version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 7
level transmitter for liquids and solids applications.
C) 7ML5673SITRANS LC300, PFA coated cable version
An inverse frequency shift capacitance continuous
7 7 7 77 - 77 7 7
level transmitter for liquids and solids applications.
Process connection
Threaded, 316L stainless steel
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B
0202]
Welded flange, 316L stainless steel, raised face1)
0D
1D
3D
Probe material
PFA coated cable and 316L stainless steel cable
weight, PEEK isolator and PFA lined active shield
1½" ASME, 150 lb
1½" ASME, 300 lb
1½" ASME, 600 lb
5D
5E
5F
Flame Proof Enclosure With IS Probe
CE, C-TICK, ATEX II 1/2 G EEx d [ia] IIC T6...T1,
ATEX II 1/2 D T100 °C
C
2" ASME, 150 lb
2" ASME, 300 lb
2" ASME, 600 lb
5G
5H
5J
D
3" ASME, 150 lb
3" ASME, 300 lb
3" ASME, 600 lb
5K
5L
5M
Dust Ignition Proof With IS Probe
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
Explosion Proof Enclosure With IS Probe
CSA/FM Class I, Div. 1, Gr. A, B, C, D
CSA/FM Class II, Div. 1, Gr. E, F, G
CSA/FM Class III T4
4" ASME, 150 lb
4" ASME, 300 lb
4" ASME, 600 lb
Welded flange, 316L stainless steel, Type A flat
faced1)
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
5N
5P
5Q
DN 50, PN 40
DN 80, PN 16
DN 80, PN 40
6F
6G
6H
DN 100, PN 16
DN 100, PN 40
6J
6K
Approvals
General Safety (CSA, FM, CE, C-TICK)
Dust Ignition Proof With IS Probe
CE, C-TICK, ATEX II 1/2 D T100 °C
Enclosure
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP65
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP65
Aluminum epoxy coated 2 x ½" NPT via adapter cable inlet, IP68
6C
6D
6E
Aluminum epoxy coated 2 x M20 x 1.5 cable inlet,
IP68
Mounting eye
Without Mounting eye
With mounting eye
1)
Probe Length
(from flange face or including
process thread)
Add order code Y01 and plain text:
"Insertion length ... mm"
1000 ... 2000 mm (39.37 ... 78.74 inch)
2001 ... 4000 mm (78.78 ... 157.48 inch)
4001 ... 6000 mm (157.52 ... 236.22 inch)
A
B
C
6001 ... 8000 mm (236.26 ... 314.96 inch)
8001 ... 10000 mm (315.00 ... 393.70 inch)
10001 ... 12000 mm (393.74 ... 472.44 inch)
D
E
F
12001 ... 14000 mm (472.48 ... 551.18 inch)
14001 ... 16000 mm (551.22 ... 629.92 inch)2)
16001 ... 18000 mm (629.96 ... 708.66 inch)2)
G
H
J
18001 ... 20000 mm (708.70 ... 787.40 inch)2)
20001 ... 22000 mm (787.44 ... 866.14 inch)2)
22001 ... 24000 mm (866.18 ... 944.88 inch)2)
K
L
M
24001 ... 25000 mm (944.92 ... 984.25 inch)2)
N
Thermal isolator
Without thermal isolator
With thermal isolator [for process connection
temperatures over +85 °C (+185 °F)]
Wetted seals
FKM
FFKM [for process temperatures above -20 °C
(-4 °F)]
5/304
Siemens FI 01 · 2012
2)
0
1
0
1
1
A
B
E
A
B
C
D
0
1
Flange bolting patterns and facings dimensionally correspond to the
applicable ASME B16.5 or EN 1092-1 standard.
Cable lengths from 15000 (590.55 inch) to 25000 mm (984.25 inch) can be
used in non-conductive media. Contact Factory for assistance.
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
English
French
German
Spanish
Multi-language Quick Start manual
Order No.
C) 7ML1998-5HE03
7ML1998-5HE11
C) 7ML1998-5HE33
7ML1998-5HE21
C) 7ML1998-5QH81
Note: The Operating Instructions should be ordered
as a separate line item on the order.
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
5
Accessories
Electronic transmitter kit (includes transmitter
and driver)
C) 7ML1830-1KN
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
C) Subject to export regulations AL: N, ECCN: EAR99.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Siemens FI 01 · 2012
5/305
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
■ Characteristic curves
Pressure/Temperature Curve
LC300 Standard, Extended Rod and Cable Probes
Threaded Process Connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
5
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
Example:
Permitted operating pressure = 30 bar (435 psi) at 75 °C
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5625)
5/306
Siemens FI 01 · 2012
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Pressure/Temperature Curve
LC300 Standard, Extended Rod and Cable Probes
ASME Flanged Process Connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted Operating Pressures P
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
ASME 6001)
50 bar (725 psi)
40 bar (580 psi)
5
30 bar (435 psi)
ASME 300
1)
20 bar (290 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 1501)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
-29 ºC
(-20 ºF)
1)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)
Pressure/Temperature Curve
LC300 Standard, Extended Rod and Cable Probes
EN Flanged Process Connections
(7ML5670, 7ML5671, 7ML5672 and 7ML5673)
Permitted Operating Pressures P
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC300 Process Pressure/Temperature derating curves (7ML5626)
Siemens FI 01 · 2012
5/307
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
■ Dimensional drawings
Threaded (7ML5670)
Threaded (7ML5671)
Lid
2 cable entries
1/2" NPT or
M20 x 1.5
Y02 1)
*
Vent
PFA
insulated
probe
Ø19 (0.75)
Y01 (insertion length)
min. = 300 (14) / max. = 5000 (197)
Lid without window
Stainless steel
stilling well
Measuring length
5
M20: 135 (5.32)
1/2" NPT: 150 (5.91)
Thermal
isolator
Note:
1) Rod version Y02: Shield length = 100 mm
(3.9") for threaded including process
connection thread length, 100 mm (3.9")
for welded flange
2) For non-conductive applications only.
Non-insulated cable can be shortened on
site. Weight is included in measuring
length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
Weight is not included in measuring
length.
4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
*
PFA
insulated
probe
Y01 (insertion length)
min. = 300 (14) / max. = 5000 (197)
measuring length
Y02 1)
20 (0.79)
Ø35 (1.38)
Ø19 (0.75)
* = 30 (1.18) Inactive tip
Cable version, non-insulated
Threaded (7ML5672)
2)
Cable version, insulated
Threaded (7ML5673)
275 (10.83)
Electronics/
enclosure
150
(5.91)
Lid clip
3)
Ø32 (1.26)
Stainless steel
weight (electrically
isolated but not PFA
insulated)
Ø34,5 (1.36)
SITRANS LC300 dimensions - Threaded Process connections, dimensions in mm (inch)
5/308
Siemens FI 01 · 2012
350 (13.78)
Ø9 (0.35)
Ø34,5 (1.36)
Mounting eye
Ø12
(0.47)
Ø25 (0.98)
20 (0.79)
Ø9 (0.35)
Y01 (insertion length)
min. = 1000 (40) / max. = 25000 (984)
Y02 =
105
(4.13)
Measuring
length
PFA insulated
cable
See
note 4)
350 (13.78)
Stainless steel
weight
250 (9.84)
Ø6 (0.24)
Y01 (insertion length)
min. = 1000 (40) / max. = 25000 (984)
Stainless steel
cable
Measuring length
Y02 =
105
(4.13)
20 (0.79)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
Welded Flange (7ML5670)
Welded Flange (7ML5671)
2 cable entries
½" NPT or
M20 x 1.5
Lid
Lid clip
Electronics/
enclosure
M20: 135 (5.32)
1/2" NPT: 150 (5.91)
PFA
insulated
probe
Ø19 (0.75)
150
(5.91)
Thermal
isolator
Flange Facing (raised face)
Flange Class
2 (0.08)
ASME 600/900
7 (0.28)
PN16/40
2 (0.08)
5
Notes:
1) Rod version Y02: Shield length = 100 mm
(3.9") for threaded including process
connection thread length, 100 mm (3.9")
for welded flange.
2) For non-conductive applications only.
Non-insulated cable can be shortened on
site. Weight is included in measuring
length.
3) For liquids and solids applications.
Insulated cable cannot be shortened.
Weight is not included in measuring
length.
4) For conductive materials, the measuring
length includes the exposed PFA insulated
cable only. Any fluid contact with the upper
rod assembly will result in a short circuit
and incorrect readings.
Ø9 (0.35)
Stainless steel
weight (electrically
isolated but not PFA
insulated)
Y01 (insertion length)
min. = 1000 (40) / max. = 25000 (984)
Y02 =
105
(4.13)
Measuring
length
PFA insulated
cable
See
note 4)
350 (13.78)
250 (9.84)
Ø6 (0.24)
Cable version, insulated 3)
Welded Flange (7ML5673)
Y01 (insertion length)
min. = 1000 (40) / max. = 25000 (984)
Stainless steel
cable
Measuring length
Y02 =
105
(4.13)
Cable version, non-insulated 2)
Welded Flange (7ML5672)
Ø9 (0.35)
350 (13.78)
Ø35 (1.38)
* = 30 (1.18) inactive tip
Ø32 (1.26)
Facing thickness
ASME 150/300
Ø34,5 (1.36)
Mounting eye
Ø12
(0.47)
Ø25 (0.98)
20 (0.79)
*
Ø19 (0.75)
Stainless steel
weight
275 (10.83)
Measuring length
Vent
Y01 (insertion length)
min. = 300 (14) / max. = 5000 (197)
Y02 1)
Stainless steel
stilling well
*
Y01 (insertion length)
min. = 300 (14) / max. = 5000 (197)
Y02 1)
measuring length
PFA
insulated
probe
Lid without window
Ø34,5 (1.36)
SITRANS LC300 dimensions - Flanged Process connections, dimensions in mm (inch)
Siemens FI 01 · 2012
5/309
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300
■ Schematics
with safety barrier
without safety barrier
white (S)
orange (S)
black (O)
black (O)
red (+)
red (+)
4 ... 20 mA (2-wire) current loop
measurement signal (not polarity
sensitive)
for factory software
update use only
menu / function selector
5
SITRANS LC300 connections
5/310
Siemens FI 01 · 2012
down / - button
up / + button
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
■ Overview
■ Configuration
Installation
Build up of material or condensation in active shield area
does not affect switch operation.
5
SITRANS LC500 is an inverse frequency shift capacitance level
or interface transmitter for extreme and critical process conditions, such as oil and liquified natural gas (LNG) as well as toxic
and aggressive chemicals and vapours.
■ Benefits
• Patented Active-Shield technology so measurement is
unaffected by material buildup in active shield section
• Simple push-button calibration and integrated local display
• Inverse frequency approach provides high resolution
• 2-wire loop powered 4 to 20/20 to 4 mA measurement signal
• Pre-detection alarm and full function diagnostics
• High temperature and pressure resistant (optional)
• Full-function diagnostics comply with NAMUR NE 43
• Easy calibration locally or via HART
(using SIMATIC PDM software)
■ Application
SITRANS LC500’s advanced electronics provide one-step,
push-button calibration and local display for easy on-site installation and setup.
The unique mechanical probe design coupled with a high performance transmitter gives superior performance in toxic and
aggressive chemicals, acids, caustics, adhesives and in viscous conductive and non-conductive materials.
The SMART 2-wire transmitter has HART communications for remote commissioning and inspection.
• Key Applications: Oil/water or foam/liquid interface measurement in separators or coalescers, cryogenic applications including CO2 and liquified natural gas (LNG), distillation/regeneration tanks with high temperatures
Mounting on non-linear vessels in non-conductive fluids
using stilling well.
SITRANS LC500 installation
■ Technical specifications
Input
Measuring range
1 … 3300 pF
Span
Min. 3.3 pF
Output
Solid-state switch
• Output
Galvanically isolated
• Protection
Bipolar
• Max. switching voltage
• 30 V (DC)
• 30 V peak (AC)
• Max. load current
82 mA
• Voltage drop
< 1 V, typical at 50 mA
• Time delay (pre or post switching)
1 … 60 s
Loop current
3.6 … 22 mA/22 … 3.6 mA
(2-wire current loop)
Accuracy (transmitter)
Temperature stability
0.15 pF (0 pF) or < 0.25%
(typically < 0.1%) of actual measured value, whichever is greater
over the full temperature range
Non-linearity and repeatability
< 0.1% of range and actual
measured value respectively
Accuracy
Deviation < 0.1% of measured
value
Siemens FI 01 · 2012
5/311
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Rated operating conditions1)
Power supply
Installation conditions
• Location
User Interface
Indoor/outdoor
Display
Local LCD, 4 digit, each 0 … 9
and limited alpha characters
• Ambient temperature (transmitter)
-40 … +85 °C (-40 … +185 °F)2)
Rotary function switch
For selecting programmable
menu items
• Installation category
II
Push buttons
• Pollution degree
4
Red +, blue -, used in conjunction
with rotary switch for programming
Ambient conditions
Medium conditions
• Relative dielectric constant εr
Min. 1.5
• Process temperature
Temperature rating of process
seal is pressure dependent.
See Pressure/Temperature curves
on page 5/321.
- Standard (PFA)3)
- Cryogenic version
5
12 … 33 V DC
Features
Measurement current signalling
According to NAMUR NE 43,
signal 3.8 … 20.5 mA,
fault ≤ 3.6 or ≥ 21 mA (22 mA)
Safety
• Inputs/outputs fully galvanically
isolated
• Polarity-insensitive current loop
• Fully potted
• Integrated safety barrier
Diagnostics with fault alarm when:
Primary variable (PV) out of limits,
system failure in measurement
circuit, deviation between A/D
and D/A converter, check sum,
watch dog and self-checking
facility
Function rotary switch
Positions 0 … 9, A … F
SMART communication
Conforming to HART
Communication Foundation
(HCF)
-50 … +200 °C (-58 … +392 °F)
-200 … +200 °C
(-328 … +392 °F)
Contact [email protected]
for details.
• Process pressure
Pressure rating of process seal is
temperature dependent.
See Pressure/Temperature curves
on page 5/321.
• Standard (PFA)
-1 … 150 bar g (2175 psi g)
Design
Material
Certificates and approvals
• Wetted parts material
- Standard rod
316L stainless steel
General Purpose
CE, CSA, FM, C-TICK
• Probe insulation (rod)
PFA
Non-incendive/Non-sparking
• Cable
316 stainless steel/
316 stainless steel PFA
• CSA/FM Class 1, Div. 2,
Groups A, B, C, D T4 ATEX II 3G
2D EEx nA [ib] IIC
• T6 … T4 T100 °C
Dust Ignition Proof
(Intrinsically Safe Probe Circuit)
• CSA/FM Class II and III, Div. 1,
Groups E, F, G
• ATEX II 1/2 GD EEx d [ia]
T6 … T1 T100 °C
Explosion Proof
(Intrinsically Safe Probe Circuit)
• FM Class 1, Div. 1,
Groups A, B, C, D T4
• ATEX II 1/2 GD EEx d [ia]
IIC T6 … T1
Marine
Lloyds Register of Shipping,
Categories ENV1, ENV2, ENV3
and ENV5, Bureau Veritas
Probe diameter
• Rod version
16 mm (0.63 inch) or 24 mm
(0.95 inch)
• Cable version
9 mm (0.35 inch) with PFA jacket,
6 mm (0.24 inch) without PFA
jacket
Active shield length
• Minimum (rod version)
50 mm (1.97 inch), customer
selectable (order number Y02)
Probe length
• Rod version
Max. 3.5 m (138 inch) with 16 mm
rod, PFA
Max. 5.5 m (216 inch) with 24 mm
rod, PFA
• Cable version
Max. 35 m (1378 inch)
Process connection of probe
• Threaded mounting
NPT [(Taper),
ANSI/ASME B1.20.1]
R [(BSPT), EN 10226/PT (JIS-T),
JIS B 0203]
G [(BSPP), EN ISO 228-1/PF
(JIS-P), JIS B 0202]
• Flange mounting
ASME, EN 1092-1
Enclosure
• Material
Aluminium, epoxy-coated
• Cable inlet
2 x ½" NPT (2 x M20x1.5, IP68
adapter, optional)
• Degree of protection
Type 4X/NEMA4X/IP65, IP68
5/312
Siemens FI 01 · 2012
1)
When operation is in areas classified as hazardous, observe restrictions
according to relevant certificate. See also Pressure/Temperature curves on
page 5/321.
2)
Thermal isolator is used if process connection temperature exceeds
+85 °C (+185 °F).
3)
Not recommended for steam environments
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
SITRANS LC500 probe version
Standard
Extended Cable version with
Rod Sensor
Process connection types
Threaded or welded flange
Single piece flanged
Threaded or welded flange
Threaded
Available as standard
–
Available as standard
Flange
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Available as standard
Rod length for PFA 16 mm version
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Min. 200 mm (7.87 inch)
Max. 3 500 mm (137.80 inch)
Rod length for PFA 24 mm version
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Min. 200 mm (7.87 inch)
Max. 5 500 mm (216.54 inch)
Cable length
Min. 1 000 mm (39.37 inch)
Max. 35 000 mm (1377.95 inch)
Min. 1 000 mm (39.37 inch)
Max. 35 000 mm (1377.95 inch)
Min. 5 000 mm (196.85 inch)2)
Max. 35 000 mm (1377.95 inch)2)
Maximum process pressure
See Pressure/Temperature curves for specific probe type
Process connection materials
Stainless steel 316L
Probe insulation
PFA
Length and Process
parameters1)
Maximum process temperature
1)
2)
5 bar g (73 psi g)
+100 °C (+212 °F)
See Pressure/Temperature curves for specific probe type
Refers to total insertion length. See dimension drawing on page 5/331 for further explanation - Not available as standard
Siemens FI 01 · 2012
5
5/313
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
5
Selection and Ordering data
C)
SITRANS LC500, Threaded or Welded Flange
with Cable Sensor
Inverse frequency shift capacitance level and interface transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Version1)
Cable, 9 mm (0.35 inch) diameter, 316 stainless
steel with PFA insulation, weighted
Add order code Y01 and plain text:
"Insertion length ... mm"
1000 ... 2000 mm (39.37 ... 78.74 inch)
2001 ... 4000 mm (78.78 ... 157.48 inch)
4001 ... 6000 mm (157.52 ... 236.22 inch)
6001 ... 8000 mm (236.26 ... 314.96 inch)
8001 ... 10000 mm (315 ... 393.70 inch)
Longer lengths possible to a max. of 35000 mm
(114.83 ft). Contact [email protected] for
details.
Cable, 6 mm (0.24 inch) diameter, 316L stainless
steel, non-insulated, weighted (non-conductive
media only)
Add order code Y01 and plain text:
"Insertion length ... mm"
1000 ... 2000 mm (39.37 ... 78.74 inch)2)
2001 ... 4000 mm (78.78 ... 157.48 inch)2)3)
4001 ... 6000 mm (157.52 ... 236.22 inch)2)3)
6001 ... 8000 mm (236.26 ... 314.96 inch)2)3)
8001 ... 10000 mm (315 ... 393.70 inch)2)3)
Cable lengths up to 25000 mm (984.25 inch) are
possible for non-conductive media. Cable lengths
up to 15000 mm (590.55 inch) are possible for
conductive media.
Contact [email protected] for details.
Process connection (316L Stainless steel)
Threaded connection
1½" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B
0202]
Welded flange, raised face
1½", ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib3)
3", ASME, 300 Ib3)
3", ASME, 600 Ib3)
4", ASME, 150 Ib3)
4", ASME, 300 Ib3)
4", ASME, 600 Ib3)
6", ASME, 150 Ib3)
6", ASME, 300 Ib3)
6", ASME, 600 Ib3)
Welded flange, Type A flat faced
DN 40, PN 16
DN 40, PN 40
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 403)
DN 100, PN 163)
DN 100, PN 403)
DN 125, PN 163)
DN 125, PN 403)
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)
5/314
Siemens FI 01 · 2012
Order No.
7ML55137 7 7 77 - 777 7
0E
1E
2E
3E
4E
0F
1F
2F
3F
4F
Selection and Ordering data
Order No.
C) 7ML5513SITRANS LC500, Threaded or Welded Flange
with Cable Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 7 7 - 7 7 7 7
face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Approvals
General Purpose: CE, CSA, FM, C-TICK, KC
1
CSA / FM Class I, Div 2, Groups A, B, C, D
2
CSA / FM Class II, III, Div 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100°C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100°C
4
FM Class I, Div.1, Groups A, B, C, D, T4
6
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
1
2 x M20x1.5 (IP68, adapter)
2
Options
No additional options
A
With mounting eye4)
B
Thermal isolator
Without thermal isolator
A
Isolator, only for use when temperature range is
B
outside of -40 ... +85 °C (-40 ... +185 °F), explosion
proof approval -40 ... +70 °C (-40 ... +158 °F)
Electronic output
2-wire loop current 4 ... 20 mA
1
(transmitter MSP 2002-2 _3300 pF)
1)
A minimum span of 3 pF must be maintained
Available with non-conductive media only
Custom shipping methods required. Contact factory for more details.
4) Available in PFA insulated version only
2)
3)
C) Subject to export regulations AL: N, ECCN: EAR99.
C0
F0
K0
L0
B1
B2
B3
C1
C2
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
K4
K5
L4
L5
M4
M5
N4
N5
P4
P5
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification (max. 16
characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Operating Instructions
See page 5/320
Accessories
See page 5/320
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Threaded or Welded Flange, C)
with Rod Sensor
Inverse frequency shift capacitance level and interface transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Version
Rod, 16 mm (0.63 inch), PFA insulated
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1000 mm (7.87 ... 39.37 inch)1)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)
3001 ... 3500 mm (118.15 ... 137.80 inch)2)
Rod, 16 mm (0.63 inch), PFA insulated with 35 mm
(1.38 inch) stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1000 mm (7.87 ... 39.37 inch)1)3)
1001 ... 2000 mm (39.41 ... 78.74 inch)3)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)3)
3001 ... 3500 mm (118.15 ... 137.80 inch)2)3)
Rod, 24 mm (0.94 inch), PFA insulated
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1000 mm (7.87 ... 39.37 inch)4)
1001 ... 2000 mm (39.41 ... 78.74 inch)4)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)4)
3001 ... 4000 mm (118.15 ... 157.48 inch)2)4)
4001 ... 5000 mm (173.26 ... 196.88 inch)2)4)
5001 ... 5500 mm (196.89 ... 216.54 inch)2)4)
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm
(1.89 inch) stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
200 ... 1000 mm (7.87 ... 39.37 inch)5)
1001 ... 2000 mm (39.41 ... 78.74 inch)5)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)5)
3001 ... 4000 mm (118.15 ... 157.48 inch)2)5)
4001 ... 5000 mm (173.26 ... 196.88 inch)2)5)
5001 ... 5500 mm (196.89 ... 216.54 inch)2)5)
Process connection (316L Stainless steel)
Threaded connection
¾" NPT [(Taper), ANSI/ASME B1.20.1]
1" NPT [(Taper), ANSI/ASME B1.20.1]
1½" NPT [(Taper), ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
1¼" NPT [(Taper), ANSI/ASME B1.20.1]
G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P),
JIS B 0202]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202]
Order No.
7ML55157 7 7 77 - 777 7
0A
1A
2A
3A
0B
1B
2B
3B
0C
1C
2C
3C
4C
5C
0D
1D
2D
3D
4D
5D
A0
B0
C0
D0
E0
F0
J0
K0
N0
P0
R0
S0
T0
Selection and Ordering data
Order No.
SITRANS LC500, Threaded or Welded Flange, C) 7ML5515with Rod Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 7 7 - 7 7 7 7
face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Welded flange, raised face
1½", ASME, 150 Ib
B1
1½", ASME, 300 Ib
B2
1½", ASME, 600 Ib
B3
2", ASME, 150 Ib
C1
2", ASME, 300 Ib
C2
2", ASME, 600 Ib
C3
3", ASME, 150 Ib2)
D1
3", ASME, 300 Ib2)
D2
3", ASME, 600 Ib2)
D3
2)
4", ASME, 150 Ib
E1
4", ASME, 300 Ib2)
E2
2)
4", ASME, 600 Ib
E3
6", ASME, 150 Ib2)
F1
6", ASME, 300 Ib2)
F2
2)
6", ASME, 600 Ib
F3
Welded flange, Type A flat faced
DN 40, PN 16
K4
DN 40, PN 40
K5
DN 50, PN 16
L4
DN 50, PN 40
L5
DN 80, PN 16
M4
DN 80, PN 402)
M5
DN 100, PN 162)
N4
DN 100, PN 402)
N5
DN 125, PN 162)
P4
DN 125, PN 402)
P5
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)
Approvals
1
General Purpose: CE, CSA, FM, C-TICK, KC
CSA / FM Class I, Div 2, Groups A, B, C, D
2
CSA / FM Class II, III, Div 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100°C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100°C
4
FM Class I, Div.1, Groups A, B, C, D, T4
6
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
1
2 x M20 x1.5 (IP68, adapter)
2
Options
No additional options
A
Slotted holes instead of standard vent holes in stilB
ling well (refer to Operating Instructions for dimen6)
sions.)
Thermal isolator/remote version
Without thermal isolator or remote electronics
A
Thermal isolator, only for use when temperature
B
range is outside of -40 ... +85 °C (-40 ... +185 °F),
explosion proof approval -40 ... +70 °C
(-40 ... +158 °F)
Remote electronics with mounting bracket and
cable7)
• Length: 2 m (79 inch)
C
• Length: 3 m (118 inch)
D
• Length: 4 m (158 inch)
E
• Length: 5 m (197 inch)
F
Siemens FI 01 · 2012
5/315
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Selection and Ordering data
Order No.
SITRANS LC500, Threaded or Welded Flange, C) 7ML5515with Rod Sensor
Inverse frequency shift capacitance level and inter- 7 7 7 7 7 - 7 7 7 7
face transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Electronic output
2-wire loop current 4 ... 20 mA
1
(transmitter MSP 2002-2 _3300 pF)
1)
2)
3)
4)
5)
6)
7)
A minimum span of 3 pF must be maintained
Custom shipping methods required. Contact factory for more details.
Available with process connection 1½" or larger
Available with process connection 1" or larger
Available with process connection 2" or larger
Available with version 0B … 3B, 0D … 5D and 0F only
Available with approval option 1 only
C) Subject to export regulations AL: N, ECCN: EAR99.
5
5/316
Siemens FI 01 · 2012
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Active shield length, specify in plain text [min.
length is 50 mm (2 inch)]: Y02: ... mm
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification (max. 16
characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturing Test Report (Electrode Test)
C18
Operating Instructions
See page 5/320
Accessories
See page 5/320
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Single Piece Flanged with Rod C)
Sensor
Inverse frequency shift capacitance level and interface transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Version
Rod, 16 mm (0.63 inch), PFA insulated
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1000 mm (9.84 ... 39.37 inch)1)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)
3001 ... 3500 mm (118.15 ... 137.80 inch)2)
Rod, 16 mm (0.63 inch), PFA insulated with 35 mm
(1.34 inch) stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1000 mm (9.84 ... 39.37 inch)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)
3001 ... 3500 mm (118.15 ... 137.80 inch)2)
Rod, 24 mm (0.94 inch), PFA insulated
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1000 mm (9.84 ... 39.37 inch)
1001 ... 2000 mm (39.41 ... 78.74 inch)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)
3001 ... 4000 mm (118.15 ... 157.48 inch)2)
4001 ... 5000 mm (173.26 ... 196.88 inch)2)
5001 ... 5500 mm (196.89 ... 216.54 inch)2)
Rod, 24 mm (0.94 inch), PFA insulated with 48 mm
(1.89 inch) stilling well in 316L stainless steel
Add order code Y01 and Y02 and plain text:
"Insertion length ... mm and active shield
length ... mm"
250 ... 1000 mm (9.84 ... 39.37 inch)
1001 ... 2000 mm (39.41 ... 78.74 inch)2)3)
2001 ... 3000 mm (78.78 ... 118.11 inch)2)3)
3001 ... 4000 mm (118.15 ... 157.48 inch)2)3)
4001 ... 5000 mm (173.26 ... 196.88 inch)2)3)
5001 ... 5500 mm (196.89 ... 216.54 inch)2)3)
Process connection (316L Stainless steel)
Single piece flange, raised face
1½", ASME, 150 Ib
1½", ASME, 300 Ib
1½", ASME, 600 Ib
2", ASME, 150 Ib
2", ASME, 300 Ib
2", ASME, 600 Ib
3", ASME, 150 Ib2)
3", ASME, 300 Ib2)
3", ASME, 600 Ib2)
4", ASME, 150 Ib2)
4", ASME, 300 Ib2)
4", ASME, 600 Ib2)
6", ASME, 150 Ib2)
6", ASME, 300 Ib2)
6", ASME, 600 Ib2)
Order No.
7ML55177 7 7 77 - 7777
0A
1A
2A
3A
0B
1B
2B
3B
0C
1C
2C
3C
4C
5C
0D
1D
2D
3D
4D
5D
B1
B2
B3
C1
C2
C3
D1
D2
D3
E1
E2
E3
F1
F2
F3
Selection and Ordering data
Order No.
SITRANS LC500, Single Piece Flanged with Rod C) 7ML5517Sensor
77 7 77 - 777 7
Inverse frequency shift capacitance level and interface transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Single piece flange, Type B1 raised face
DN 40, PN 16
K4
DN 40, PN 40
K5
DN 50, PN 16
L4
DN 50, PN 40
L5
DN 80, PN 16
M4
DN 80, PN 402)
M5
DN 100, PN 162)
N4
DN 100, PN 402)
N5
DN 125, PN 162)
P4
DN 125, PN 402)
P5
Single piece flange with PTFE flange facing (applicable with versions 0A ... 3A and 0C ... 5C)4)
1½", ASME, 150 Ib
B4
1½", ASME, 300 Ib
B5
1½", ASME, 600 Ib
B6
2", ASME, 150 Ib
C4
2", ASME, 300 Ib
C5
2", ASME, 600 Ib
C6
3", ASME, 150 Ib2)
D4
3", ASME, 300 Ib2)
D5
3", ASME, 600 Ib2)
D6
4", ASME, 150 Ib2)
E4
4", ASME, 300 Ib2)
E5
2)
4", ASME, 600 Ib
E6
6", ASME, 150 Ib2)
F4
6", ASME, 300 Ib2)
F5
2)
6", ASME, 600 Ib
F6
Single piece flange with PTFE flange facing
(applicable with versions 0A ... 3A, 0C ... 5C)4)
DN 40, PN 16
K6
DN 40, PN 40
K7
DN 50, PN 16
L6
DN 50, PN 40
L7
DN 80, PN 16
M6
DN 80, PN 402)
M7
DN 100, PN 162)
N6
DN 100, PN 402)
N7
DN 125, PN 162)
P6
DN 125, PN 402)
P7
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)
Siemens FI 01 · 2012
5/317
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
5
Selection and Ordering data
Order No.
SITRANS LC500, Single Piece Flanged with Rod C) 7ML5517Sensor
7 7 7 77 - 7777
Inverse frequency shift capacitance level and interface transmitter for extreme and critical process
conditions, such as oil and liquid gas, toxic and
aggressive chemicals and vapours.
Approvals
1
General Purpose: CE, CSA, FM, C-TICK, KC
CSA / FM Class I, Div 2, Groups A, B, C, D
2
CSA / FM Class II, III, Div 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100°C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100°C
4
FM Class I, Div.1, Groups A, B, C, D, T4
6
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
1
2 x M20 x1.5 (IP68, adapter)
2
Options
None
A
Slotted holes instead of standard vent holes in
B
stilling well (Refer to manual for dimensions)5)
Thermal isolator/remote version
Without thermal isolator
A
Isolator, only for use when temperature range is
B
outside of -40 ... +85 °C (-40 ... +185 °F), explosion
proof approval -40 ... +70 °C (-40 ... +158 °F)
Remote electronics with mounting bracket and
cable6)
• Length: 2 m (79 inch)
C
• Length: 3 m (118 inch)
D
• Length: 4 m (158 inch)
E
• Length: 5 m (197 inch)
F
Electronic output
2-wire loop current 4 ... 20 mA
1
(transmitter MSP 2002-2 _3300 pF)
1)
A minimum span of 3 pF must be maintained
Custom shipping methods required. Contact factory for more details.
Available with process connection 2" or larger, and only available with
process connection options C1 to F3, L4 to P5
4) Not available with versions 0E and 0F
5)
Available with version 0B to 3B, 0D to 5D and 0F only
6)
Available with approval option 1 only
2)
3)
C) Subject to export regulations AL: N, ECCN: EAR99.
5/318
Siemens FI 01 · 2012
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: ... mm
Y01
Active shield length, specify in plain text
[min. length is 50 mm (2 inch)]: Y02: ... mm
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Manufacturing Test Report (Electrode Test)
C18
Operating Instructions
See page 5/320
Accessories
See page 5/320
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Selection and Ordering data
SITRANS LC500, Extended Cable version with C)
Rod Sensor, threaded connection or welded
flange1)
Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels.
Version2)
Rod, 16 mm (0.63 inch), PFA insulated and 316L
stainless steel flexible extension tube
Total insertion length:
Add order code Y01 and5/314ain text: "Total insertion length ... mm and Y02 and plain text:
Active shield length ... mm"3)4)
• 5000 ... 10000 mm (196.85 ... 393.70 inch)1)
• 10001 ... 15000 mm (393.74 ... 590.55 inch)1)
• 15001 ... 20000 mm (590.59 ... 787.40 inch)1)
• 20001 ... 25000 mm (787.44 ... 984.25 inch)1)
• 25001 ... 30000 mm (984.29 ... 1181.10 inch)1)
• 30001 ... 35000 mm (1181.14 ... 1377.95 inch)1)
Rod, 24 mm (0.94 inch), PFA insulated and 316L
stainless steel flexible extension tube
Total insertion length:
Add order code Y01 and plain text: "Total insertion
length ... mm and Y02 and plain text:
Active shield length ... mm"3)4)
• 5000 ... 10000 mm (196.85 ... 393.70 inch)1)
• 10001 ... 15000 mm (393.74 ... 590.55 inch)1)
• 15001 ... 20000 mm (590.59 ... 787.40 inch)1)
• 20001 ... 25000 mm (787.44 ... 984.25 inch)1)
• 25001 ... 30000 mm (984.29 ... 1181.10 inch)1)
• 30001 ... 35000 mm (1181.14 ... 1377.95 inch)1)
Process connection (316L stainless steel)
Threaded connection
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203]
G 2" [(BSPP), EN ISO 228-1/PF (JIS-P) JIS B 0202]
Welded flange, raised face
2", ASME, 150 Ib
2", ASME, 300 Ib
3", ASME, 150 Ib1)
3", ASME, 300 Ib1)
4", ASME, 150 Ib1)
4", ASME, 300 Ib1)
6", ASME, 150 Ib1)
6", ASME, 300 Ib1)
Welded flange, Type A flat faced
DN 50, PN 16
DN 50, PN 40
DN 80, PN 16
DN 80, PN 401)
DN 100, PN 161)
DN 100, PN 401)
DN 125, PN 161)
DN 125, PN 401)
(Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16.5,
or EN 1092-1 standard.)
Approvals
General Purpose: CE, CSA, FM, C-TICK, KC
CSA / FM Class I, Div 2, Groups A, B, C, D
CSA / FM Class II, III, Div 1, Groups E, F, G T4
ATEX II 3G 2D EEx nA [ib] IIC T6 ... T4 T 100°C
ATEX II 1/2 GD EEx d [ia] IIC T6 ... T1 T 100°C
FM Class I, Div 1, Groups A, B, C, D T4
Order No.
7ML55237 7 7 77 - 777 7
0A
1A
2A
3A
4A
5A
Selection and Ordering data
Order No.
SITRANS LC500, Extended Cable version with C) 7ML5523Rod Sensor, threaded connection or welded
7 7 7 77 - 777 7
flange1)
Inverse frequency shift capacitance level and interface transmitter for short range continuous measurement in large storage vessels.
Enclosure/Cable inlet
Aluminum epoxy coated
2 x ½" NPT, IP68
1
2 x M20x1.5 (IP68, adapter)
2
Options
No additional options
A
With mounting eye
B
Thermal isolator
Without thermal isolator
A
Isolator, only for use when temperature range is
B
outside of -40 ... +85 °C (-40 ... +185 °F), explosion
proof approval -40 ... +70 °C (-40 ... +158 °F)
Electronic output
2-wire loop current 4 ... 20 mA
1
(transmitter MSP 2002-2 _3300 pF)
1)
Custom shipping methods required. Contact factory for more details.
A minimum span of 3 pF must be maintained.
See dimension drawings on page 5/331 for further explanation of Y01.
4)
Inactive length is equal to the flexible extension plus transition.
See dimension drawings on page 5/331 for further explanation of Y02.
2)
3)
0B
1B
2B
3B
4B
5B
A0
B0
D0
C1
C2
D1
D2
E1
E2
F1
F2
L4
L5
M4
M5
N4
N5
P4
P5
1
2
4
6
Siemens FI 01 · 2012
5/319
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Order code
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Insertion length, specify in plain text: Y01: to mm
Y01
Active shield length, specify in plain text
[min. length is 50 mm (2 inch)]: Y02: to mm
Y02
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 16 characters) specify in plain text
Y15
Acceptance test certificate: Manufacturer's test
certificate M to DIN 55350, Part 18 and ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Order No.
Operating Instructions
English
C) 7ML1998-5GE03
French
C) 7ML1998-5GE12
Spanish
C) 7ML1998-5GE21
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
5
7ML1998-5GE33
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick Start
and Operating Instructions library.
Accessories
Transmitter, MSP 2002-1, 330 PF1)
C) 7ML1830-1JP
Transmitter, MSP 2002-2, 3300 PF1)
C) 7ML1830-1JQ
Transmitter, MSP 2002-3, 6600 PF (used with con- D) 7ML1830-1JR
ductive fluids and probe lengths >10000 mm)1)
SITRANS RD100 Remote display - see Chapter 8
SITRANS RD200 Remote display - see Chapter 8
K) 7ML5750SITRANS RD500 web, datalogging, alarming,
ethernet, and modem support for instrumentation 1AA00-0
see Chapter 8
1)
Transmitters not suitable for Intrinsically Safe application
(ATEX II 1G EEx ia IIC T4 or CSA/FM Class 1 Div 1 Grp A,B,C and D)
C) Subject to export regulations AL: N, ECCN: EAR99.
D) Subject to export regulations AL: N, ECCN: EAR99H.
K) Subject to export regulations AL: N, ECCN: 5A991X.
Please contact [email protected] for special requests.
5/320
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
■ Characteristic curves
Pressure/Temperature Curve
LC500 Cable Probes
Threaded Process Connections
(7ML5513)
Permitted Operating Pressures P
30 bar (435 psi)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
5
Permitted Operating Temperature T
Example:
Permitted operating pressure = 10 bar (145 psi) at 75 °C
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
Siemens FI 01 · 2012
5/321
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 PFA Rod Probes
Threaded Process Connections
(7ML5515)
Permitted Operating Pressures P
150 bar (2,175 psi)
140 bar (2,030 psi)
130 bar (1,885 psi)
120 bar (1,740 psi)
110 bar (1,595 psi)
5
100 bar (1,450 psi)
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
20 bar (290 psi)
atmospheric
10 bar (145 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
-29 ºC
(-20 ºF)
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515)
5/322
Siemens FI 01 · 2012
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Cable Probes
ASME Flanged Process Connections
(7ML5513)
Permitted Operating Pressures P
20 bar (290 psi)
10 bar (145 psi)
ASME 150 lb1)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
5
Siemens FI 01 · 2012
5/323
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 PFA Rod Probes
ASME Flanged Process Connections
(7ML5515 and 7ML5517)
Permitted Operating Pressures P
150 bar (2,175 psi)
140 bar (2,030 psi)
130 bar (1,885 psi)
120 bar (1,740 psi)
110 bar (1,595 psi)
5
100 bar (1,450 psi)
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
ASME 300 lb1)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
5/324
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Cable Probes
EN Flanged Process Connections
(7ML5513)
Permitted Operating Pressures P
20 bar (290 psi)
10 bar (145 psi)
PN 161)
atmospheric
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5513)
5
Siemens FI 01 · 2012
5/325
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 PFA Rod Probes
EN Flanged Process Connections
(7ML5515 and 7ML5517)
Permitted Operating Pressures P
150 bar (2,175 psi)
140 bar (2,030 psi)
130 bar (1,885 psi)
120 bar (1,740 psi)
110 bar (1,595 psi)
5
100 bar (1,450 psi)
90 bar (1,305 psi)
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
10 bar (145 psi)
atmospheric
-40 ºF 14 ºF
(-40 ºC)(-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
PN 161)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
5/326
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Enamel Rod Probes
ASME Flanged Process Connections (7ML5515 and 7ML5517)
Permitted Operating Pressures P
360 bar (5,366 psi)
340 bar (4,931 psi)
320 bar (4,641 psi)
300 bar (4,351 psi)
280 bar (4,061 psi)
260 bar (3,771 psi)
240 bar (3,481 psi)
5
220 bar (3,191 psi)
200 bar (2,900 psi)
180 bar (2,610 psi)
160 bar (2,320 psi)
140 bar (2,030 psi)
120 bar (1,740 psi)
100 bar (1,450 psi)
80 bar (1,160 psi)
60 bar (870 psi)
ASME 600 lb1)
40 bar (580 psi)
ASME 300 lb1)
atmospheric
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
ASME 150 lb1)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
Siemens FI 01 · 2012
5/327
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Enamel Rod Probes
EN Flanged Process Connections (7ML5515 and 7ML5517)
Permitted Operating Pressures P
360 bar (5,366 psi)
340 bar (4,931 psi)
320 bar (4,641 psi)
300 bar (4,351 psi)
280 bar (4,061 psi)
260 bar (3,771 psi)
240 bar (3,481 psi)
5
220 bar (3,191 psi)
200 bar (2,900 psi)
180 bar (2,610 psi)
160 bar (2,320 psi)
140 bar (2,030 psi)
120 bar (1,740 psi)
100 bar (1,450 psi)
80 bar (1,160 psi)
60 bar (870 psi)
40 bar (580 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 401)
20 bar (290 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5515 and 7ML5517)
5/328
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
PN 161)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Single Piece Flanged Rod Probes with PTFE facing
EN Flanged Process Connections
(7ML5517)
Permitted Operating Pressures P
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
PN 401)
20 bar (290 psi)
atmospheric
-40 ºF 14 ºF 100 ºF
(-40 ºC) (-10 ºC) (38 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
PN 161)
10 bar (145 psi)
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)
Siemens FI 01 · 2012
5/329
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Pressure/Temperature Curve
LC500 Single Piece Flanged Rod Probes with PTFE facing
ASME Flanged Process Connections
(7ML5517)
Permitted Operating Pressures P
80 bar (1,160 psi)
70 bar (1,015 psi)
60 bar (870 psi)
ASME 600 lb1)
50 bar (725 psi)
40 bar (580 psi)
30 bar (435 psi)
5
ASME 300 lb1)
20 bar (290 psi)
-40 ºF 14 ºF
(-40 ºC) (-10 ºC)
-1 bar (-14.5 psi)
-150 ºC
(-238 ºF)
ASME 150 lb1)
10 bar (145 psi)
atmospheric
-100 ºC -50 ºC
(-148 ºF) (-58 ºF)
100 ºF
(38 ºC)
0 ºC RT 50 ºC
(32 ºF)
(122 ºF)
200 ºF
(93 ºC)
100 ºC
(212 ºF)
300 ºF
(149 ºC)
150 ºC
(302 ºF)
-29 ºC
(-20 ºF)
1)
The curve denotes the minimum allowable flange class for the shaded area below.
SITRANS LC500 Process Pressure/Temperature derating curves (7ML5517)
5/330
Siemens FI 01 · 2012
400 ºF
(204 ºC)
200 ºC
(392 ºF)
500 ºF
(260 ºC)
250 ºC
(482 ºF)
600 ºF
(315 ºC)
300 ºC
(572 ºF)
700 ºF
(371 ºC)
350 ºC
400 ºC
(662 ºF) (752 ºF)
Permitted Operating Temperature T
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
■ Dimensional drawings
Cable version, non-insulated
welded flange (7ML5513)
Cable version, insulated
welded flange (7ML5513)
Transmitter/
electronics
Option for mounting eye
only available for PFA
insulated cable
Stainless
steel weight
Ø40
(1.57)
Mounting
eye
Ø12 (0.47)
Ø25 (0.98)
Ø48 (1.88)
Ø24
(0.94)
Ø35
(1.37)
Measuring
Y02 Inactive length
length
Y01 (insertion length)
min. = 5000 (197) / max. = 35000 (1378)
Mounting
eye option
54 (2.12)
Stainless
steel
flexible
tube
20
(0.79)
Y02 Inactive length
Y01 (insertion length)
min. = 5000 (197) / max. = 35000 (1378)
Measuring
length
63
92
(3.62) (2.48)
20 (0.79)
92
(3.62)
350 (13.78)
Ø12
(0.47)
Ø25 (0.98)
5
Extended cable version with rod sensor
welded flange (7ML5523)
Extended cable version with rod sensor
welded flange (7ML5523)
Ø16
(0.63)
Mounting
eye
Ø34.5 (1.36)
Ø32 (1.26)
Stainless
steel
flexible
tube
Ø34.5 (1.36)
20 (0.79)
Measuring
length
Ø9 (0.35)
Ø9 (0.35)
Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
part of measuring length.
3) For Y02 lengths greater than 5000 (197),
cable is inactive and is not actively
shielded.
4) Minimum length = 200 (7.87)
5) Insertion length Y01 =
Y02 + measuring length + 92 (3.62)
6) Insertion length Y01 =
Y02 + measuring length + 15 (0.59)
Mounting
eye option
Inactive tip
100 (3.9)
Stainless
steel weight
Y01 (insertion length)
min. = 1000 (39.40) / max. = 35000 (1378)
250 (9.84)
Ø6 (0.24)
PFA insulated
probe
350 (13.78)
Masuring length
Stainless
steel cable
Y01 (insertion length)
min. = 1000 (39.40) / max. = 35000 (1378)
20 (0.79)
15 (0.60)
SITRANS LC500 - Cable Versions, dimensions in mm (inch)
Siemens FI 01 · 2012
5/331
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Cable version, non-insulated 1)
Welded flange (7ML5513)
Cable version, insulated 2)
Welded flange (7ML5513)
Transmitter/
electronics
Option for mounting eye
only available for PFA
insulated cable
Ø25 (0.98)
Ø40
(1.57)
Mounting
eye
Ø12 (0.47)
Ø25 (0.98)
Ø24
(0.94)
Ø35
(1.37)
15 (0.60)
350 (13.78)
Note:
1) Applicable for non-conductive media only.
Cable can be shortened on site. Weight is
included in measuring length.
2) Applicable for both liquids and solids.
Cable cannot be shortened. Weight is not
part of measuring length.
3) For Y02 lengths greater than 5000 mm
(197"), cable is inactive and is not actively
shielded.
4) Minimum length = 200 mm (7.87")
5) Insertion length Y01 =
Y02 + measuring length + 92 mm (3.62")
6) Insertion length Y01 =
Y02 + measuring length + 15 mm (0.59")
Mounting
eye option
Inactive tip
100 (3.9)
20
(0.79)
Mounting
eye option
Measuring
Y02 Inactive length
length 4)
6)
Y01 (insertion length)
min. = 5000 (197) / max. = 35000 (1378)
Y01 (insertion length)
min. = 5000 (197) / max. = 35000 (1378)
5)
Y02 Inactive length
63
92
(3.62) (2.48)
Measuring
length 4)
Stainless
steel
flexible
tube
SITRANS LC500 - Cable Versions, dimensions in mm (inch)
Siemens FI 01 · 2012
Ø12
(0.47)
Extended cable version with rod sensor 3)
Welded flange (7ML5523)
Ø48 (1.88)
5/332
Mounting
eye
Ø34.5 (1.36)
Extended cable version with rod sensor 3)
Welded flange (7ML5523)
Ø16
(0.63)
Ø34.5 (1.36)
20 (0.79)
Stainless
steel weight
Ø32 (1.26)
Stainless
steel
flexible
tube
Y01 (insertion length)
max. = 35000 (1378)
Measuring
length
350 (13.78)
Ø9 (0.35)
54 (2.12)
Stainless
steel weight
92
(3.62)
5
250 (9.84)
Ø6 (0.24)
PFA insulated
probe
Y01 (insertion length)
max. = 35000 (1378)
Measuring length
Stainless
steel cable
Ø9 (0.35)
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Rod version with stilling well
Threaded (7ML5515)
stainless steel
stilling well
measuring length1)
vent holes or
optional slots
PFA insulated
probe
*
Ø16 (0.63)
or Ø24 (0.94)
150 (6)
205 (8.1)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5500 (216), Ø24 (0.94)
Ø16 (0.63)
or Ø24 (0.94)
Y02 1)
205 (8.1)
*
PFA insulated
probe
Y01 (insertion length)
min. = 200 (7.87) / max. = 3500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5500 (216), Ø24 (0.94)
measuring length1)
20
(0.79)
Y02 1)
transmitter/
electronics
Remote electronics with mounting bracket option
Threaded (7ML5515)
stainless steel flexible tube
General Purpose approval only.
Standard configuration
(all versions)
205 (8.1)
Rod version
Threaded (7ML5515)
5
M20: 160 (6.3)
1/2" NPT: 230 (9.1)
With thermal isolator
option (all versions)
Ø35 (1.38)
or Ø48 (1.89)
* = 30 (1.18) Inactive tip
270 (10.6)
Note:
1) Minimum Y02 (active shield length) = 50 (1.96),
minimum measuring length = 200 (7.87)
430 (16.9)
With explosion-proof
seal option
(all versions)
thermal
isolator
SITRANS LC500 - Rod Versions, dimensions in mm (inch)
Siemens FI 01 · 2012
5/333
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
Rod version
Welded flange (7ML5515)
Single piece flange (7ML5517)
Rod version with stilling well
Welded flange (7ML5515)
Single piece flange (7ML5517)
150 (6)
Y02 1)
General Purpose approval only.
2)
vent holes or
optional slots
PFA insulated
probe
Ø16 (0.63)
or Ø24 (0.94)
Ø35 (1.38)
or Ø48 (1.89)
Ø16 (0.63)
or Ø24 (0.94)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5500 (216), Ø24 (0.94)
*
5
stainless steel
stilling well
measuring length1)
PFA insulated
probe
stainless steel flexible tube
*
Y02 1)
measuring length1)
2)
Y01 (insertion length)
min. = 200 (7.87) / max. = 3500 (138), Ø16 (0.63)
min. = 200 (7.87) / max. = 5500 (216), Ø24 (0.94)
205 (8.1)
(Typical)
transmitter/
electronics
Remote electronics with mounting bracket option
Welded flange (7ML5515)
Single piece flange (7ML5517)
PTFE flange facing option
Single piece flange only (7ML5517)
raised face
flange
PTFE flange
facing
No stilling well or enamel probe available with this
option.
* = 30 (1.18) Inactive tip
Flange Facing (raised face)
Standard configuration
(all versions)
205 (8.1)
Flange Class
M20: 160 (6.3)
1/2" NPT: 230 (9.1)
Facing thickness
ASME 150/300
2 (0.08)
ASME 600/900
7 (0.28)
PN16/25/40/64
2 (0.08)
PTFE facing (additional)
2 (0.08)
With thermal isolator
option (all versions)
Notes:
1) Minimum Y02 (active shield length) = 50 (1.96),
minimum measuring length = 200 (7.87)
2) Insertion length does not include any raised face/gasket face
dimension (see Flange Facing table above).
270 (10.6)
430 (16.9)
With explosion-proof
seal option (all
versions)
thermal
isolator
SITRANS LC500 - Rod Versions, dimensions in mm (inch)
5/334
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC500
■ Schematics
Ground lug
Protective
label
Instrument
system
ground
Measuring
signal
(mini-coaxial
cable)
Solid state
switch relay
(any polarity)
4-20 mA
Current loop
connection
(any polarity)
Ground connection point
for instrument system
5
SITRANS LC500 connections
Siemens FI 01 · 2012
5/335
© Siemens AG 2011
Level Measurement
Continuous level measurement — Capacitance transmitters
SITRANS LC300/LC500 Specials
■ Selection and ordering data
LC300 and LC500 Specials. See note 1.
LC300 and LC500 Specials. See note 1.
Order No.
LC300 Cable Extensions, 316L stainless
steel
5
Order No.
LC300 Weight Kit, 316L stainless steel
Kit, Stainless steel cable extension, 1 m,
adjustable by customer
A5E01163688
Kit, Stainless steel cable extension, 3 m,
adjustable by customer
A5E01163689
Kit, Stainless steel cable extension, 5 m,
adjustable by customer
A5E01163690
Kit, Stainless steel cable extension, 10 m,
adjustable by customer
A5E01163691
Kit, Stainless steel cable extension, 15 m,
adjustable by customer
A5E01163693
Kit, Stainless steel cable extension, 20 m,
adjustable by customer
A5E01163695
Kit, Spare stainless steel weight. To be used
in any cable version of CLS300, or stainless
steel cable version of LC300
A5E01163727
LC500 Gasket (IP65), Silicone
Spare gasket, LC500 enclosure version, IP65 J) A5E01163728
LC500 Blind Lid
LC300 Cable Extensions,
316 stainless steel with PFA coating
Spare LC500 aluminum blind lid
Kit, PFA cable extension, 1 m
A5E01163709
Kit, PFA cable extension, 3 m
A5E01163710
Kit, PFA cable extension, 5 m
A5E01163711
Kit, PFA cable extension, 10 m
A5E01163712
Kit, PFA cable extension, 15 m
A5E01163713
Kit, PFA cable extension, 20 m
A5E01163714
LC300 Mounting Eye
A5E01163729
LC500 Mounting Eye
Spare mounting eye (PFA cable version only)
A5E01163717
LC500 Mounting Bracket
Spare mounting eye (LC300 PFA versions
only)
A5E01163717
Spare mounting bracket
A5E01163730
LC500 Sanitary Versions
See note 2.
J) Subject to export regulations AL: 91999, ECCN: EAR99.
Note 1: Special flange sizes and facings are available. Please
contact [email protected] for part number and pricing.
Submit Application Questionnaire found on page 5/9.
Note 2: Please contact [email protected] for part number
and pricing. Submit Application Questionnaire found on page
5/9.
Please contact [email protected] for special requests.
5/336
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Continuous level measurement — Open channel flow — Ultrasonic controller
OCM III
■ Overview
■ Benefits
• Influent and effluent monitor
• BS 3680 calculations provide exceptional accuracy in
measuring flow
• 1 to 24 months data log, subject to logging rate
• RS-232 serial communication
• High accuracy on unique or non-standard weirs and flumes
• AC and DC operation. Automatically switches to battery
operation for uninterrupted power
• Dual power input
• Low power remote monitoring
• Flow Reporter software available for remote monitoring,
configuration and data retrieval
■ Application
The OCM III is a high accuracy ultrasonic flow monitor for open
channels.
In addition to monitoring flowrate in sewage works, OCM III can
monitor industrial discharge, rainfall/storm water studies, inflow/infiltration studies and sewer system evaluations. As well as
being compatible with many standard weirs and flumes, the programmable head versus flow curve (up to 16 points) accurately
defines flow rate on unique or non-standard weirs and flumes.
The OCM III has data logging and is adjustable from once per
minute to once a day. It records the average flow rate for that
time period. Daily, it records minimum/maximum of temperature
and flow rates, and the time they occurred, as well as the daily
total. Advanced functions include variable rate logging. It can be
pre-programmed to log at a higher rate when needed. Under
steady conditions, the OCM III automatically logs less frequently
to conserve data log space.
The OCM III has two-way communication via RS-232 with a modem or a bi-polar current loop with a current-to-voltage communication converter. Data logs can be downloaded to a file that
can be manipulated into a spreadsheet or ASCII format.
Siemens FI 01 · 2012
5/337
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Open channel flow — Ultrasonic controller
OCM III
■ Technical specifications
Certificates and approvals
0.3 … 1.2 m (1 … 4 ft)
or 0.6 … 3 m (2 … 10 ft)
CE, FM, CSAUS/C, MCERTS,
C-TICK2)
Communication
RS-232 or ± 20 mA bipolar current loop, 300, 600, 1200, 2400,
4800, 9600, 19200 baud
Transducer
Echomax XRS-5, 44 kHz
Options
Relays
3 alarm/control relays, 1 SPDT
Form C contact per relay, rated
5 A at 250 V AC non-inductive
or 30 V DC
Mode of Operation
Measuring range1)
Output
mA output
• Max. load
0/4 … 20 mA, isolated
• Resolution
5 uA
• Isolation
300 V AC continuous
1 KΩ max. load
+24 V DC, 20 mA average to
200 mA at 1/10 duty cycle
max. 0 … 20
Accuracy
Error in measurement
±1 mm/m, calculated error less
than 0.02%
Resolution
0.2 mm (0.007")
Rated operating conditions
Installation conditions
• Location
Indoor/outdoor
• Installation category
II
• Pollution degree
4
Ambient conditions
• Ambient temperature (enclosure)
-20 … +50 °C (-5 … +122 °F)
Design
Weight
2.3 kg (5.1 lbs)
Material (enclosure)
Polycarbonate
Degree of protection (enclosure)
IP65/Type 4X/NEMA 4X
Cable
Transducer and mA output signal
• Transducer: co-axial to be
RG62-A/U low capacity
• mA output signal to be
2 copper conductors, twisted,
with foil shield/drain wire, 300 V
0.5 … 0.75 mm² (22 … 18 AWG)
• Relay/power to be copper
conductors per local
requirements to meet 250 V
5 A contact rating
Max. separation between
transducer and transceiver
183 m (600 ft)
Displays and controls
LCD 5 x 7 dot matrix display with
2 lines of 40 characters each
Programming
Via removable programmer and
communication link
Memory
3 V battery (NEDA 5003LC or
equivalent), operating life 1 year,
SuperCap capacitor for back-up
during battery replacement
Power supply
AC version
100/115/200/230 V AC ± 15%,
50/60 Hz, 20 VA max.
DC version
9 … 30 V DC, 8 W max.
5/338
TS-2
Flow Reporter, a Windows-based
configuration software and data
extractor
Velocity sensor input
Input range: 0 … 10 V DC
Resolution: 2.7 mV
1)
2)
• DC output
5
Temperature sensor
Remote monitoring
Siemens FI 01 · 2012
Program range is defined as the empty distance to the face
of the transducer plus any range extension
EMC performance available upon request
Windows is a registered trademark of Microsoft Corporation
© Siemens AG 2011
Level Measurement
Continuous level measurement — Open channel flow — Ultrasonic controller
OCM III
Selection and Ordering data
OCM III
High accuracy ultrasonic flow monitor for open
channels.
Input voltage
AC, voltage selector switch
Enclosure
Wall mount, standard enclosure
Wall mount, 6 entries, M20 holes1)
Approvals
CSAUS/C, FM, CE (EN61326), C-TICK
CE2)
1) Available with approval option 6 only
2) Available with enclosure option B only
C) Subject to export regulations AL: N, ECCN: EAR99.
Order No.
C) 7ML1002-
7A7 07
Order No.
Selection and Ordering data
Further designs
Please add "-Z" to Order No. and specify Order
code(s).
Operating Instructions
0
A
B
5
6
English
C) 7ML1998-5AB01
French
C) 7ML1998-1AB11
Spanish
C) 7ML1998-1AB21
German
Note: The Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1998-1AB31
This device is shipped with the Siemens Milltronics
manual CD containing the complete ATEX Quick
Start and Operating Instructions library.
Required equipment
TS-2 Temperature Sensor
C) 7ML1812-1AA1
TS-2, 1 m cable
C) 7ML1812-2AA1
TS-2, 5 m cable
C) 7ML1812-3AA1
TS-2, 10 m cable
C) 7ML1812-4AA1
TS-2, 30 m cable
C) 7ML1812-5AA1
TS-2, 50 m cable
C) 7ML1812-6AA1
TS-2, 70 m cable
C) 7ML1812-7AA1
TS-2, 90 m cable
C) 7ML1998-
TS-2 Operating Instructions
Note: The TS-2 Operating Instructions should be
ordered as a separate line item on the order.
C) 7ML1812-1AA1
5EW01
Accessories
Handheld programmer
7ML1830-2AA
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"),
one text line, suitable for enclosure
7ML1930-1AC
M20 cable gland kit (6 M20 cable glands,
6 M20 nuts, 3 stop plugs)
7ML1830-1GM
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
Flow Reporter software license
B) 7ML1930-1AK
Flow Reporter Kit (includes disk, authorization
code and cable)
B) 7ML1930-1AL
Spare parts
Card, Mother, main
C) 7ML1830-1MG
Card, daughter/display
C) 7ML1830-1LT
Eprom
C) 7ML1830-1KW
Battery
C) 7ML1830-1JV
OCM III Lid overlay
7ML1830-1KV
B) Subject to export regulations AL: N, ECCN: EAR99S.
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/339
5
© Siemens AG 2011
Level Measurement
Continuous level measurement — Open channel flow — Ultrasonic controller
OCM III
■ Dimensional drawings
209 (8.2)
172 (6.8)
106 (4.2)
91 (3.6)
Lid screws (6 places)
267 (10.5)
285 (11.2)
16 (0.6)
Programmer
5
Lid
Suitable location for conduit entrances.
Siemens Milltronics recommends using
a punch for making holes in enclosure.
Enclosure
Mounting holes
(accessed under lid)
4.3 mm (0.17") dia. /
4 places
Customer mounting
screw
OCM III, dimensions in mm (inch)
Transducer
Current O/P
Bipolar I/O
RS-232 I/O
16
17
18
19
20
+
+
Vel
Aux
Input
Input
0-10 V
Temp. Sensor
21
P24V
15
SYNC
14
COM
13
SHLD
–
12
WHT
+
11
BLK
–
10
RXD
+
9
COM
8
TXD
7
TX
–
6
TX
+
5
SHLD
4
RX
3
SHLD
2
SHLD
Hot
1
RX
■ Schematics
22
23
24
+
–
25
26
27
28
29
30
31
32
34
35
36
L2/N L1
9-30 V
P 24 V Output Input
max. load
Power
average 20 mA
Pulse 200 mA
1/10 duty
33
RL1
RL2
RL3
Position SW1
for 100/115/
200/230 V AC
operation
(50/60 Hz,
20 VA)
Notes:
1. Use RG62-A/U coaxial (or equivalent) for extensions up to 183 m (600 ft).
Run in grounded metal conduit, separate from other wiring.
2. Each relay has 1 set of form 'C' (SPDT) contacts, relay rated at 5 A, 250 V AC, non-inductive, when equal or lower rated limiting fuses are installed.
Relay de-energized when in alarm conditions and energized for pump control.
OCM III connections
5/340
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Communication
SmartLinx module
■ Overview
SmartLinx modules provide direct digital connection to popular
industrial communications buses with true plug-and-play compatibility with products manufactured by Siemens.
■ Benefits
• Fast, easy installation
• Direct connection: no additional installation required
• Scaleable application layer allows for optimized network
bandwidth and memory requirements
• Modules available for PROFIBUS DP, Allen-Bradley
Remote I/O and DeviceNet, Modbus RTU
■ Application
Many Siemens products include HART, PROFIBUS PA and Modbus communications. For additional communication modules,
SmartLinx cards are the answer.
■ Technical specifications
Module type
Allen Bradley Remote I/O
• Interface
RIO
• Transmission rate
57.6, 115.2 or 230.4 Kbaud
• Rack address
1 … 73, ¼ to full rack
• Connection
RIO slave
• SmartLinx module compatibility
• SITRANS LU01
• SITRANS LU02
• SITRANS LU10
• SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200
Module type
PROFIBUS DP
• Interface
RS-485 (PROFIBUS standard)
• Transmission rate
All valid PROFIBUS DP rates from
9600 Kbps … 12 Mbps
• Rack address
0 … 99
• Connection
Slave
• SmartLinx module compatibility
• SITRANS LU01
• SITRANS LU02
• SITRANS LU10
• SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200
Module type
Modbus RTU
• Interface
RS-232 or RS-485
• Transmission rate in bps
1200, 2400, 4800, 9600, 19200,
38400
• Rack address
1 … 247
• Connection
Slave
• SmartLinx module compatibility
• SITRANS LU01
• SITRANS LU02
• SITRANS LU10
Included with product:
• SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200
They’re fast and easy to install, and can be added at any time.
The module simply plugs into the socket on any SmartLinx-enabled product. They require no secondary private buses or gateways and no separate wiring. There are no extra boxes to connect to your network so there’s a minimum load on engineering
and maintenance staff.
SmartLinx provides all data from the instrument, including measurement and status, and allows changes to operation parameters to be done over the bus or telemetry link. The user can select which data in the application layer to transfer over the bus.
This selection saves bandwidth and memory and optimizes data
throughput and speeds up the network, enabling you to connect
more instruments to your network.
5
Module type
DeviceNet
• Interface
DeviceNet physical layer
• Transmission rate in kbps
125, 250, 500
• Rack address
0 … 63
• Connection
Slave (group 2)
• SmartLinx module compatibility
• SITRANS LUC500
• MultiRanger 100/200
• HydroRanger 200
Siemens FI 01 · 2012
5/341
© Siemens AG 2011
Level Measurement
Communication
SmartLinx module
Selection and Ordering data
Order No.
SmartLinx module for SITRANS LU01, LU02,
LU10
Allen-Bradley Remote I/O module
7ML1830-1CP
PROFIBUS DP module
7ML1830-1CQ
Modbus RTU module
7ML1830-1CR
SmartLinx module for SITRANS LUC500 Rack
and Panel Mount models
Allen-Bradley Remote I/O module
7ML1830-1HP
PROFIBUS DP module
7ML1830-1CS
DeviceNet module
7ML1830-1HQ
SmartLinx module for SITRANS LUC500
Wall Mount model, MultiRanger 100/200,
HydroRanger 200
Allen-Bradley Remote I/O module
C) 7ML1830-1HS
PROFIBUS DP module
7ML1830-1HR
DeviceNet module
7ML1830-1HT
Operating Instructions
5
Allen-Bradley Remote I/O communications
module, English
C) 7ML1998-1AP03
PROFIBUS communications module
• English
C) 7ML1998-1AQ03
• French
C) 7ML1998-1AQ13
• German
C) 7ML1998-1AQ33
Modbus RTU communications module, English
C) 7ML1998-1BF01
Modbus RTU communications module, French
C) 7ML1998-1BF11
Modbus RTU communications module, German
C) 7ML1998-1BF31
SmartLinx modem, English
C) 7ML1998-1BG01
C) 7ML1998-1BH02
DeviceNet
This device is shipped with the Siemens Milltronics
manual CD containing Quick Starts and Operating
Instructions.
• English
C) 7ML1998-1BH02
• French
C) 7ML1998-1BH12
Spare SmartLinx software
Allen-Bradley data diskette
C) 7ML1830-1CK
PROFIBUS DP data diskette
C) 7ML1830-1CL
DeviceNet data diskette
C) 7ML1830-1CM
C) Subject to export regulations AL: N, ECCN: EAR99.
5/342
Siemens FI 01 · 2012
© Siemens AG 2011
Level Measurement
Communication
Dolphin Plus Software
■ Overview
Compatibility
Dolphin Plus is compatible with Microsoft Windows
95/98/NT4/Me/2000/XP and works with a wide range of Siemens
products, including:
• SITRANS LUC500
• HydroRanger Plus
• SITRANS LU10
• SITRANS LU02
• SITRANS LU01
Connection to a Siemens instrument may be a direct RS-232 serial connection or via an RS-485 converter or Siemens infrared
ComVerter, depending on the instrument being configured.
Meets VDE 2187 user interface requirements.
(Most other Siemens level devices use Simatic PDM configuration software.)
Order No.
Selection and Ordering data
Dolphin Plus is instrument configuration software that allows you
to quickly and easily configure, monitor, tune and diagnose
several Siemens level devices remotely (see list below). Remote
access is available using your desktop PC or connected directly
in the field using a laptop.
■ Benefits
•
•
•
•
•
•
•
Real-time monitoring and adjustment of parameters
On-screen visualization of process values
Saving and visualization of echo profiles for a wide range of
Siemens level meters
Copying of data for programming several devices
Quick setup and commissioning of device
Generation of configuration reports within seconds
N) 7ML1841Dolphin Plus
Instrument configuration software to quickly and
7AA 0 7
easily configure, monitor, tune and diagnose most
Siemens devices remotely, from your desktop PC or
connected directly in the field using a laptop.
Dolphin Plus Software includes a software CD, and
a nine pin adapter with a 2.1 m (82.7 inch) cable for
connection to a PC serial port.
RS-485 to RS-232 converter
No
Yes
ComVerter
No
Yes
Selection and Ordering data
The Dolphin Plus software is only available in English.
Operating Instructions
Dolphin Plus is easy to install and use. Just load the software
from the CD. In minutes, you’re ready to set up or modify complete parameter configurations for one or more devices.
Following configuration, you can alter parameters, upload and
download parameter sets to and from disk, and use parameter
sets saved from other instruments. Reading of echo profiles permits fine tuning without the need for special instruments. Built-in
quick start wizards and help functions guide you through the entire process.
0
1
N) Subject to export regulations AL: N, ECCN: 5D992.
Note:
■ Application
0
1
Order No.
Connection manual, English:
Included on Dolphin Plus CD and available at
www.siemens.com/processautomation
Spare parts
Converter, RS 485 to RS 232 (D-Sub)
C) 7ML1830-1HA
Kit containing one 9-pin D-Sub to RJ11 Adapter
and one 2.1 meter telephone cable with two male
jacks
ComVerter, Infrared link
7ML1830-1MC
C) 7ML1830-1MM
C) Subject to export regulations AL: N, ECCN: EAR99.
Siemens FI 01 · 2012
5/343
5
© Siemens AG 2011
Level Measurement
Notes
5
5/344
Siemens FI 01 · 2012
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement