Universal LED dimmer moduleArt. no. CCT99100© Schneider-Electric 2014EAV56166-0109/15
en
The dimmer module automatically recognises the connected load. It is overload-proof, short-circuit-proof, protected from overheating and it has a soft-start function.
Universal LED dimmer module
Wiring the dimmer module
L
N
The memory function allows the dimmer module to
memorise the most recently set brightness value and retrieve it again.
You can set the dimming range and adjust the operating
mode (from trailing edge phase to leading edge phase).
Operating instructions
L
1
L
½
CAUTION
The dimmer may be damaged!
• Always operate the dimmer according to the
technical data provided.
• Connected dimmers may be damaged if you
connect a combination of loads (inductive and
capacitive) at the same time.
Art. no. CCT99100
Installing the dimmer module
• The dimmer is designed for sinusoidal mains
voltages.
• If transformers are used, only connect dimmable transformers to the dimmer.
Accessories
• Dimming socket outlets is prohibited. The risk
of overload and connecting unsuitable dimmers is too high.
Complete the universal LED dimmer module with:
• Mechanical retractive push-buttons in design series of
free choice
• If a terminal is used for looping, the insert must
be protected with a 10 A circuit breaker.
For your safety
Connections, displays and operating
elements
DANGER
Risk of serious damage to property and personal injury, e.g. from fire or electric shock,
due to incorrect electrical installation.
Safe electrical installation can only be ensured if
the person in question can prove basic knowledge in the following areas:
¼
A
c
B
• Connecting to installation networks
• Connecting several electrical devices
• Laying electric cables
These skills and experience are normally only
possessed by skilled professionals who are
trained in the field of electrical installation technology. If these minimum requirements are not met
or are disregarded in any way, you will be solely liable for any damage to property or personal injury.
¼
DANGER
Risk of death from electric shock.
The outputs may carry an electrical current even
when the device is switched off. Always disconnect the fuse in the incoming circuit from the supply before working on connected loads.
The universal LED dimmer module (referred to below as
dimmer module) is suitable for installation in a deep installation box. The dimmer module is controlled with mechanical push-buttons in parallel operation. Ohmic,
inductive or capacitive loads can be switched or dimmed
with it:
L
Dimmable LED lamps
Incandescent lamps
(ohmic load)
230 V halogen lamps
(ohmic load)
Low-voltage halogen lamps with
dimmable wound transformer
(inductive load)
Low-voltage halogen lamps with
electronic transformer
(capacitive load)
When setting the operating mode or operating the
dimmer module by means of the installed programming push-button, pay attention to particular
rules for live working. Only press the programming push-button with an insulated pin, for example an insulated screwdriver that meets the
requirements of EN 60900.
Setting the dimming range
A Programming push-button
The dimming range of the dimmer module can be
adjusted.
B Status LED
C Function potentiometer
|
Mounting the dimmer module
|
Do not connect more than three dimmer modules
to one cable with 16 A fuse protection.
|
If you do not install the dimmer module in a single,
standard flush mounting box, the maximum permissible load is reduced due to the restricted heat
dissipation:
Load reduced
by
Risk of fatal injury from electric shock.
1
L
Getting to know the dimmer module
DANGER
Depending on the dimming range of the lamp,
malfunctions may occur for values near the maximum and minimum brightness. (Refer to the
chapter "What should I do if there is a problem?")
Setting the minimum and maximum brightness
RL(LED)
1
2
MIN
RESET
MAX
When installed
< 0,5 sec
In cavity walls*
25%
Several installed together in combination*
30%
In 1-gang or 2-gang surface-mounted housing
50%
In 3-gang surface-mounted housing
* If more than one factor applies, add the load reductions
together.
3
4
3x
< 0,5 sec
> 0,5 sec
5 8 sec
2 sec
The circuit breaker is switched on. (Live working.)
EAV56166-01 09/15
¼
Setting the dimmer module
1 Make sure that the connected load is turned off with
the programming push-button.
Resetting to default mode
2 Set the function potentiometer to MIN or MAX.
3 Press the programming push-button shortly 3 times.
The dimmer module is in programming mode. The
status LED flashes according to the operating mode
(see "Displaying the operating mode").
RL(LED)
1
Displaying the operating mode
2
1
1 x 0,5 sec = RC mode
2 x 0,5 sec = RL mode
3 x 0,5 sec = RL (LED)
mode
The circuit breaker is switched on. (Live working!)
1 Make sure that the connected load is turned off with
the programming push-button.
2 Press the programming push-button shortly 3 times.
The status LED displays the current operating
mode. It flashes briefly 1-3 times depending on the
operating mode.
1
2
MIN
3
The load is dimmed to the minimum brightness.
2 sec
3x
< 0,5 sec
3 sec
The circuit breaker is switched on. (Live working!)
1 Make sure that the connected load is turned off with
the programming push-button.
2 Set the function potentiometer to RESET.
3 Press the programming push-button shortly 3 times.
The dimmer module is in programming mode. The
status LED flashes according to the operating mode
(see "Displaying the operating mode").
4 Press the programming push-button for 3 seconds.
The status LED lights up for 2 seconds.
Connecting the mechanical pushbutton
¼
DANGER
Risk of death from electric shock.
However the device is turned off there might be
full voltage at the output. Always turn the device in
the status of voltage free before starting with
work.
RESET
MAX
2 sec
Operating the dimmer module
3 sec
The circuit breaker is switched on. (Live working!)
A
1 Make sure that the connected load is turned off with
the programming push-button.
The load flickers at minimum brightness.
The circuit falls short of the minimum possible brightness
value.
• Increase minimum brightness value (set dimming
range).
The load flickers continuously.
Incorrect operating mode set.
• Switch operating mode to "leading edge phase for
LED lamps" (RL LED mode).
• Alternatively, reset operating mode to default.
The load can only be dimmed slightly.
• Set dimming range.
• Switch operating mode to "leading edge phase for
LED lamps" (RL LED mode).
• Alternatively, reset operating mode to default and set
dimming range again.
Technical data
Nominal voltage:
Switching capacity:
LED lamps
(RC mode):
LED lamps
(RL LED mode):
Incandescent lamps:
230 V halogen
lamps:
LV halogen lamps with
dimmable
wound transformer:
LV halogen lamps with
electronic
transformer:
Neutral conductor:
Connecting terminals:
Extension connection:
Total cable sections:
AC 230 V ~, 50 Hz
4-100 VA
4-20 VA
5-200 W
5-150 W
5-200 VA
5-200 VA
not required
screw terminals for
max. 2.5 mm2
mechanical push-buttons
max. 20 m for 3-wire NYM cable
16 A circuit breaker
44.5 x 39.5 x 20 mm
• Short-circuit-proof
• Overload-proof
B
• Soft start
• Resistant to overheating
4 Press the programming push-button for 3 seconds.
The status LED lights up for 2 seconds.
The operating mode is switched to "leading edge phase
for LED lamps" (RL LED mode).
• Dimming range is incorrect. -> Reduce maximum
brightness value.
Fuse protection:
Dimensions (HxWxD):
Properties:
2 Set the function potentiometer to RL(LED).
3 Press the programming push-button shortly 3 times.
The dimmer module is in programming mode. The
status LED flashes according to the operating mode
(see "Displaying the operating mode").
• The circuit is overloaded. -> Reduce load.
• The circuit falls short of the minimum load. -> Increase
load.
4
3x
< 0,5 sec
• Renew defective loads.
4
< 0,5 sec
3
• Allow the dimmer to cool down and reduce the connected load.
• Rectify any possible short circuits.
< 0,5 sec
Switching the operating mode to RL LED mode
RL(LED)
MAX
The operating mode is switched to "trailing edge phase"
(RC mode) and the minimum/maximum brightness value
is reset.
3x
< 0,5 sec
< 0,5 sec
MIN
The dimmer dims down regularly during operation
and cannot be dimmed up again.
• Allow the dimmer to cool down and reduce the connected load.
Operating mode
The default setting of the dimmer module is the RC
mode. The dimmer module automatically recognises inductive load (RL mode). However, not all lamps will work
proper with the automatically recognised load. In this
case you can switch the operating mode to RL LED.
2
RESET
The load cannot be switched back on.
4 According to selection in step 2:
Set the minimum or maximum lamp brightness by
holding down the programming push-button.
5 The new value will be automatically saved after 8
seconds if the programming push-button is not
pressed again during this time.
The connected load is automatically switched off.
The status LED lights up for 2 seconds.
What should I do if there is a problem?
• Automatic
load detection
A Short press: switching on or off
|
EAV56166-01 09/15
B Long press: dimming up or down
In the operating mode "leading edge phase for
LED lamps" (RL LED mode), LED lamps can only
be connected at up to 10% of the maximum permissible dimmer load.
Dimmer tool
Schneider Electric has tested numerous dimmable LED
and energy saving lamps. The dimmer tool provides information on dimmable lamps and the minimum and
maximum number of individual lamp models.
http://schneider-electric.dimmer-test.com
Dispose of the device separately from household waste at an official collection point. Professional recycling protects people and the
environment against potential negative effects.
Schneider Electric Industries SAS
If you have technical questions, please contact the Customer Care Centre in your country.
EAV56166-01 09/15
www.schneider-electric.com
Was this manual useful for you? yes no