تبلیغات
تبلیغات
Rigel 5 v1.7 QRG Quick reference guides are not a replacement for the supplied instructions, they are supplementary Read and understand the installer warnings in the main instruction document first Always apply good, safe, state of the art engineering and electrical installation principles Safety of the completed installation is the ultimate responsibility of the installer This product is not suitable for DIY use and should only be installed and maintained by a trained, skilled, professional installer www.metalines.com [email protected] Menu System www.metalines.com [email protected] Menu Layout Parameters; Adjustable numeric settings (formerly on pots) Logic; Function ON/OFF settings (formerly on dip switches) Radio; Transmitter storage Language; Panel language selection Default; Restore panel Parameter and Logic settings to factory default www.metalines.com [email protected] Essential Parameters No. of down button presses For more options and detail see main instructions www.metalines.com [email protected] Essential Logics No. of down button presses The 12v dc lock output can accommodate 1 x 0.5A magnetic lock or 1 x 2A impulse lock For more options and detail see main instructions www.metalines.com [email protected] Essential Radio and Language “Hidden Button” www.metalines.com [email protected] Method • Set the motors in place on the correct geometry (plumb with top hinge for under ground or A = B for rams) • Install any gate stops to be used (mandatory for hydraulics-except Lux FC) • Manual release and set limit switch positions (Igea only) • Set the gates at 45° (half open/shut) and close the manual releases • Connect up the motor and supply cables (Single motor systems use only motor 2 connections) • Do not connect any accessories at this stage and leave all jumpers in place • Run the Quick menu – press OK once • • • • • • Run the motors (1 sec. link 30/31) – check that both are opening and not closing Swap terminals 5&6 or 8&9 if either gate moves in the close direction Close both gates on manual & close the manual releases Run the gates through several cycles and check settings run the traditional menu to make adjustments – press OK twice rapidly Add accessories one at a time and test each one before moving on www.metalines.com [email protected] Typical Wiring Example www.metalines.com [email protected] Wiring Connections www.metalines.com [email protected] Machine Directive Compliance Hydraulic & Electromechanical; 1. Adjust parameter to enable M1 to close 600mm before M2 Hydraulic; 2. Adjust the force at the leading edge with the CLOSE pressure screw to give under 400N in the last 500mm of closing (utilise hydraulic slow down if available) Electromechanical; 2. Adjust parameter to give 600mm of slow space 3. Adjust parameter to give under 400N during slow down Hydraulic & Electromechanical; Fit a safe edge to the leading edge of M2 Set Logics Run a full set of tests and address all other risks as appropriate www.metalines.com [email protected] ">
/
دانلود
فقط یک یادآوری دوستانه. می توانید سند را درست در اینجا مشاهده کنید. اما مهمتر از همه، هوش مصنوعی ما قبلاً آن را خوانده است. این می تواند موارد پیچیده را به زبان ساده توضیح دهد، به سوالات شما به هر زبانی پاسخ دهد و به شما کمک کند به سرعت حتی طولانی ترین یا پیچیده ترین اسناد را پیمایش کنید.
تبلیغات