Winco PPG28F4-XX/4 Installation And Operator's Manual
The Winco PPG28F4-XX/4 is a powerful, reliable generator designed for both standby and prime power applications. It features a multi-cylinder liquid-cooled engine, brushless AVR controlled generator, and is equipped with a flexible drive disk for smooth operation. This generator is capable of providing 28,000 watts of power and is compliant with current EPA regulations, making it suitable for a range of power needs. The unit is skid mounted for easy installation and comes equipped with optional accessories to enhance functionality.
PDF
Download
Document
Advertisement
Advertisement
PPG28F4-XX/4 GENERATOR INSTALLATION AND OPERATORS MANUAL COPY YOUR MODEL AND SERIAL NUMBER HERE No other WINCO generator has the same serial number as yours. If you should ever need to contact us on this unit, it will help us to respond to your needs faster. MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE _________________________________________ DEALER NAME ___________________________________________ DEALER PHONE # ________________________________________ www.wincogen.com TABLE OF CONTENTS SAVE THESE INSTRUCTIONS SAFETY INFORMATION SAFETY DEFINITIONS CALIFORNIA PROPOSITION 65 2 ENGINE CONTROLS POWER DISTRIBUTION 3 STARTING SYSTEM IGNITION SYSTEM CHARGING SYSTEM SENSORS ACTUATOR/DATA LINK CONNECTOR DRY FUEL DEPR SPECIFICATIONS4 PPG28F44 INTRODUCTION5 TESTING POLICY PRODUCT DESCRIPTION PREPARING THE UNIT START-UP CHECK LIST UNPACKING LIFTING THE GENERATOR SET MANUAL START WIRING DIAGRAM DSE7310 WIRING DIAGRAM 6 THREE PHASE AC WIRE HIGH WYE THREE PHASE AC WIRE LOW WYE INSTALLATION7 WIRING DIAGRAMS GENERAL INFORMATION ENGINE GENERATOR SET MOUNTING VENTILATION REQUIREMENTS EXHAUST INSTALLATION FUEL SYSTEM INSTALLING THE FUEL LINE ELECTRICAL CONNECTIONS GENERATOR CIRCUIT BREAKER LOAD BALANCING GROUNDING TRANSFER SWITCH DC WIRING INSTALLING THE BATTERY SERVICING BATTERIES BATTERY CHARGER BLOCK HEATER STARTING PROCEDURE LUBRICATION COOLANT PRE-START CHECK LIST MANUAL START PANEL (Standard) DSE7310 MKII (Optional) CONTROL POWER OPERATING CONDITIONS NORMAL OPERATION HARSH ENVIRONMENTS OPERATIONS COLD WEATHER OPERATIONS THREE PHASE AC WIRING- DELTA SINGLE PHASE 311 WINDING LIMITED WARRANTY 33 34 SAVE THESE INSTRUCTIONS 16 This manual contains important instructions that should be followed during installation and maintenance of the generator. Read and understand all instructions in the manual before starting and operating the generator. USING THIS MANUAL Congratulations on your choice of a WINCO generator. You have selected a high-quality, precision-engineered generator designed and tested to give you years of satisfactory service. CHANGING THE OIL CHANGING OIL FILTER FUEL FILTER FILLING COOLANT CHANGING COOLANT CLEANING RADIATOR STORAGE OPM-161/A 31 32 13 MAINTENANCE17 VOLTAGE REGULATOR MAINTENANCE SCHEDULE TROUBLE SHOOTING TABLES ENGINE HARNESS SCHEMATIC 24 To get the best performance from your new generator, it is important that you carefully read and follow the operating instructions in this manual. 20 21 22 23 Should you experience a problem please follow the “Troubleshooting Tables” near the end of this manual. The warranty listed in the manual describes what you can expect from WINCO should you need service assistance in the future. 2 SAFETY INFORMATION C. Do not smoke or use open flame near the generator set or fuel tank. D. Keep a fire extinguisher nearby and know its proper use. Fire extinguishers rated ABC by NFPA are appropriate. E. Store fuel only in an approved container, and only in a well ventilated area. F. Follow local codes for closeness to combustible material. SAVE THESE INSTRUCTIONS This engine generator set has been designed and manufactured to allow safe, reliable performance. Poor maintenance, improper or careless use can result in potentially deadly hazards; from electrical shock, exhaust gas asphyxiation, or fire. Please read all safety instructions carefully before installation or use. Keep these instructions handy for future reference. Take special note and follow all warnings on the unit labels and in the manuals. 3. DEADLY EXHAUST GAS Exhaust fumes from any internal combustion engine contain carbon monoxide, an invisible, odorless and deadly gas that must be mixed with fresh air. A. Operate only in well ventilated areas. B. Never operate indoors including attached garages C. Never operate the unit in such a way as to allow exhaust gases to seep back into closed rooms (i.e. through windows, walls, and/or floors). CALIFORNIA PROPOSITION 65 WARNING This product contains crude oil, gasoline, diesel fuel and other petroleum products, Antifreeze to which can expose you to chemicals including toluene and benzene, Ethylene glycol (ingested) which are known to the State of California to cause cancer, birth defects or other reproductive harm and developmental issues. For more information go to www.P65Warning.ca.gov. 4. NOISE HAZARD Excessive noise is not only tiring, but continual exposure can lead to loss of hearing. A. Use hearing protection when working around this equipment for long periods of time. B. Keep your neighbors in mind when using this equipment. SAFETY DEFINITIONS 5. CLEANLINESS Keep the generator and surrounding area clean. A. Remove all grease, ice, snow or materials that create slippery conditions around the unit. B. Remove any rags or other materials that could create a potential fire hazard. C. Carefully clean up any gas or oil spills before starting the unit. D. Do NOT use the generator area as a storage closet. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. 6. SERVICING EQUIPMENT All service, including the installation or replacement of service parts, should be performed only by a qualified technician. A. Use only factory approved repair parts. B. Do not work on this equipment when fatigued. C. Never remove the protective guards, covers, or receptacle panels while the engine is running. D. Use extreme caution when working on electrical components. High output voltage from this equipment can cause serious injury or death. E. Always avoid hot mufflers, exhaust manifolds, and engine parts. They can cause severe burns instantly. F. The use of the engine-generator set must comply with all national, state, and local codes. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. 1. ELECTRICAL SHOCK The output voltage present in this equipment can cause fatal electric shock. This equipment must be operated by a responsible person. A. Do not allow anyone to operate the generator without proper instruction. B. Guard against electric shock. C. Avoid contact with live terminals or receptacles. D. Use extreme care if operating this unit in rain or snow. E. Use only three-pronged grounded receptacles and extension cords. F. Be sure the unit is properly grounded, installation must meet the national electrical code. 2. FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and/or fire. A. Do not refuel when the engine is running or hot. B. Keep fuel containers out of reach of children. 3 OPM-161/A SPECIFICATIONS PPG28F4 STANDBY PRIME VOLTS PF WATTS KVA AMPS WATTS KVA AMPS 120/240 1-PH 1.0 28,000 28 116 25,000 25 104 120/208 3-PH 0.8 28,000 35 97 25,000 31.25 86 120/240 3-PH 0.8 28,000 35 84 25,000 31.25 75 277/480 3-PH 0.8 28,000 35 42 25,000 31.25 37 346/600 3-PH 0.8 28,000 35 33 25,000 31.25 30 GENERATOR RESISTANCE (all value at 22°C) Model Stamford S1L2-K1 Winding Group 711 Rotor 0.965 Ω Stator 0.177 Ω per phase series star connected Exciter Rotor 0.112 Ω per phase Exciter Stator 15.5 Ω Voltage Regulator AS540 ENGINE Model Ford MSG 425 Starting System 12 Volt Fuel Consumption (full load) Fuel Oil Type 2.7 Gal/hr Unleaded 87 or 89 Octane See Lubrication section in this manual Oil Capacity 6.7 Quarts Cooling System 50/50 mix * See engine manual for additional fuel types and specifications OPM-161/A 4 INTRODUCTION TESTING POLICY available from a nearby authorized dealer or distributor. Go to the WINCO website for a list of engine dealers (wincogen.com) or contact the WINCO Service Department. Before any generator is shipped from the factory, it is fully checked for performance. The generator is loaded to its full capacity, and the voltage, current, and frequency are carefully checked. The rated power of each engine-generator is limited by the temperature, altitude, and all other ambient conditions specified by the engine manufacturer. Rated output of generator is based on engineering tests of typical units, and is subject to, and limited by, the temperature, altitude, fuel, and other conditions specified by the manufacturer of applicable engines. Derates Above Sea Level Per 1,000 FT Temperature Above 77°F PRODUCT DESCRIPTION The engine-generator set consists of a multi-cylinder, liquidcooled engine nominally operating at 1800 RPM. This generator set meets current EPA regulations for standby or prime power use. The generator frequency regulation is maintained by the engine electronic governor to within +/- 0.5 Hertz. The generator is connected to the engine flywheel via flexible drive disks. The generator set is skid mounted with isolation mounts between the engine and base. 4% 2% Per 10°F Units should not be operated in ambient temperature greater than 120° Fahrenheit. GENERATOR: The nameplate includes a standby and prime/continuous rating. The standby rating is the maximum amount of power the generator set can produce. For prime power applications the load should be equal to or less than the prime power rating and the load is assumed to be variable. It is acceptable to occasionally reach the standby rating during prime operation to start motors or other temporary surges. NOTICE: A Customer supplied 12 Volt battery is required to complete the installation. Battery requirements are listed later under the battery installation section. WINCO generator sets use a brushless, AVR (Auto-Voltage Regulator) controlled broad-range generator ends. The generator converts rotational mechanical energy into electrical energy. These WINCO units are equipped with generators manufactured by Cummins Generator Technologies. Each generator ‘end’ has its own data tag. A unique serial number is on the data plate and the data label is affixed to the main frame on the generator on the left side. GENERATOR SET: Every WINCO generator set has its own unique identity data plate. This data plate identifies the complete unit model number, the system serial number, and has links to the individual components that form the generator set in our factory records. Several of the major components also have their own individual data plates providing additional information to document build data for warranty and replacements parts. Be sure to have the main WINCO unit data plate information recorded inside the front cover of this manual for future reference and for identification whenever requesting field or factory assistance. Primary fields needed for assistance are complete model number and serial number. ENGINE: This manual covers specific operation of the combined engine generator set. The basic engine information provided in this manual is not suitable for all operating conditions. Refer to the engine operators manual for more detailed operation and maintenance information. CAUTION: EQUIPMENT DAMAGE Be sure to check the engine oil level frequently as specified in the engine manual. The engine manufacturer has established an excellent worldwide engine service organization; engine service is 5 OPM-161/A PREPARING THE UNIT START-UP CHECK LIST Smaller generator sets may not require use of overhead lifting equipment and may be placed on the pad with basic material handling equipment, i.e. a forklift. Always use forklifts of a proper rating and with long enough forks to move the generator. As the distance from the forklift mast increases the lifting capacity for the forklift decreases. When lifting from the side the forks should extend the entire width of the unit to the opposite side frame rail. A Start-Up Completion & Warranty Validation Form was sent along with this manual. This must be completed and returned to WINCO Inc. within 180 days of the factory invoice date. If this form is not returned, the Warranty may be voided. UNPACKING CAUTION Do not attempt to lift the genset by the means of the lifting eyes on the engine or generator end. These lifting points are only for the use during the manufacturing process and are designed for lifting of the individual generator set components and not the complete unit. 1. As you receive your unit, it is critical to check it for any damage. If any damage is noted, it is always easiest to refuse the shipment and let WINCO take care of the freight claim. If you sign for the unit, the transfer of the ownership requires that you file the freight claim 2. Before proceeding with the preparations of your new generator for operation, take a couple of minutes to ensure the unit you have received is the correct model and review the specification pages in this manual to ensure that this unit meets your job requirements. CAUTION: EQUIPMENT DAMAGE These units are shipped with oil and a 50/50 mix of coolant. Be sure to check all fluid levels before operating. See engine manufacturer’s instruction manual for recommended oil requirements before initial starting. 11.9” Once generator set is on-site: 1. Carefully remove the crate. 2. After inspecting the engine-generator for external, physical damage, locate and check the following items packed with the unit: a. Installation and Operator’s Manual. b. Engine manufacturer’s instruction manual. c. Start-up and warranty validation form. d. Battery hold-down brackets & hardware. e. Unit components or accessory items shipped loose for on-site installation. f. Optional accessories. 3. Remove main frame hold-down bolts. 4. Unit can now be lifted from shipping rails. 8” 17.2” CAUTION: EQUIPMENT DAMAGE It is possible to lift the generator from the radiator side. It requires especially long forks and care should be taken to ensure that no contact is made with the radiator. Pushing the radiator will cause damage that is not covered under warranty. LIFTING THE GENERATOR SET CAUTION: PERSONAL INJURY: To prevent injury to persons or equipment, observe the following guidelines when lifting the generator. Due to the different designs, configurations, options, weights, site conditions, and available material handling equipment, specific lifting instructions are not provided for each individual generator set model. General guidelines provided are applicable to the entire generator line. It is the responsibility of the installing party to follow the lifting equipment’s operator’s manual to prevent injury to personnel and damage to the generator. OPM-161/A 8” 9” 6 INSTALLATION VENTILATION REQUIREMENTS The max ambient temperature is 120°F. This unit should be installed in a well ventilated area, ensuring the exhaust air cannot be recirculated back into the engine. WARNING: EQUIPMENT DAMAGE It is the installer’s responsibility to ensure that there is sufficient cooling air available to prevent the engine and generator from over heating. Damage caused by overheating is not covered by warranty. CAUTION This unit will get hot while it is running and for some time afterward. WARNING: PERSONAL INJURY Before proceeding with the installation, be sure the engine control is in the “stop” position and the emergency stop depressed. Also, be sure the generator MLCB (main line circuit breaker) in is the “off” position and the unit starting battery is disconnected. Providing proper air movement during your installation planning is essential. You will need to provide a fresh air inlet as well as a hot air outlet (to the outside of protection housing) for proper engine performance. These enginegenerator sets are equipped with unit mount radiators and the engine is equipped with a pusher type fan. The hot air from the face of the radiator must be ducted out of the enclosure to ensure proper cooling. Failing to do so will allow the hot air to recirculate around the radiator causing the engine to overheat, resulting in an engine shutdown and damage. If louvers are used in front of the hot air duct to protect the unit from outside weather, the louvers should be 1½ times as large as the area of the radiator face to prevent back pressure. GENERAL INFORMATION This series of engine-generator sets are designed and built as open power units, meaning no weather protection has been provided. These units must be installed inside of an enclosure that will provide proper protection from the elements. When installing, ensure that the radiator is at least 0.75” from a solid surface such as a wall or duct. The radiator is mounted on rubber vibration isolators that allow it to move. Placing the duct flange too close to a wall can result in contact that will damage the radiator resulting in costly repairs. The WINCO installation manual OPM-112 contains additional information on indoor installations and is available electronically through our website or by requesting a copy from the factory. Before beginning the installation process, recheck the voltage, phase, and amperage rating of the generator set. Be certain it can handle the intended load and are compatible with the intended loads. Plans for installation should be prepared with proper attention to mechanical and electrical engineering detail to assure a satisfactory system installation. The installation must comply with all national, state, and local codes. Foam or other seals should be used to form a tight lip forcing all of the air from the engine fan out of the enclosure. In addition to a hot air discharge, you must plan a fresh air intake opposite the radiator discharge. WARNING: EQUIPMENT DAMAGE Failure to seal the radiator output will result in hot air recirculation that will result in equipment overheating and damage. The information in this manual is offered only as a guide to finalizing your installation plans and does not substitute for sound engineering judgment for the specific application. Their fresh air inlets should be 1½ to 2 times larger than the radiator face. The extra air inlet area is required to minimize restriction and to provide combustion air for the engine. Do not block fresh air intakes with other equipment as this will result in insufficient air flow to the engine for cooling. Installing them opposite the hot air discharge will allow a sweeping flow of cooling air across the engine, preventing hot spots. ENGINE GENERATOR SET MOUNTING The unit’s main frame must be bolted securely to a solid base. The engine-generator is mounted on channels which are attached with special shock mounts to the main frame. This allows the engine-generator free movement without affecting the base or surrounding equipment. WARNING: EQUIPMENT DAMAGE Never mount these engine-generator sets to a wooden base/structure. Over time, the wood will deteriorate and the unit mountings will come loose. These units must be mounted to a steel or concrete base. EXHAUST THIMBLE AIR INLET DUCT RADIATOR DISCHARGE FOAM SEAL 7 OPM-161/A EXHAUST INSTALLATION This generator set is certified subject to running loss evaporative emissions requirements. Liquid fuel in the fuel tank may not reach boiling during continuous generator set operation at an ambient temperature of 30C. Gasoline with a Reid vapor pressure of 9 psi begins to boil at about 53C at atmospheric pressure. Position the fuel tank away from heat sources including the generator set, exhaust systems, catalysts, and other equipment. Do not mount the tank where there is no air circulation. WARNING: PERSONAL INJURY Improper exhaust installation will allow dangerous gases to seep into enclosed spaces causing a hazard to your health and/or death. All exhaust must be piped out of the enclosure. When selecting a location to exhaust fumes make sure that the potential for contact with people is controlled. Exhaust can enter buildings through windows, ventilation systems and other openings if proper precautions are not followed. Air Exhaust Fuel Tank The exhaust must be isolated from the vibration of the engine. If the exhaust is connected in a rigid system it will result in damage to the engine. The generator comes equipped with an engine mounted flex pipe to aid your installation. Ensure proper alignment with the generator. The flex can be eliminated if it is pushed to one side to make a connection. The most direct path possible should be used to get to the outside of the enclosure. Each bend restricts the pipe and increases back pressure. It may be necessary to increase the exhaust pipe diameter in some applications. Inlet Fuel Tank Air Intake 5(9,6,216 5(9 ,51 '(6&5,37,21 '$7( %< $33 ' $ &$ 1(:3$57 5/9 0&% The fuel filler neck is shipped loose and designed to be mounted to an outside wall of the enclosure. The cap will vent fuel vapor if tank pressure to too high. The exhaust pipe is very hot. When passing through the structure it is critical that a thimble or other appropriate technique is used to dissipate the heat and prevent the structure from catching on fire. 3.044” 2.58” FUEL SYSTEM 2.58” Failure to follow these instructions when installing the fuel system violates federal law (40 CFR 1068.105(b)), and is subject to fines or other penalties as described in the Clean Air Act. 2.58” 6.088” ; 7+,6$66(0%/<86(6385&+$6(.,7&20321(176127,1&/8'(',1%20 WARNING ,7(012 3$57180%(5 '(6&5,37,21 47< WARNING The supplied fuel fitting and hose are electrically *$/*$62/,1(7$1. 78%(&/$03&86+:,5(,1 conductive components. They ensure a path to ground Fuel vapors must not vent and accumulate in enclosed ,1,')8(/),//(5+26(&8772 ,1&+ and the dissipation of any static electric charge. Without compartments. 137;+26(%$5%('=,1& ),//(51(&.:(/'0(17 this conductive feature, pinhole leaks may form in the fuel %(=(/)2$0 line/hose, as the built-up electrical charge seeks ground *$62/,1(%(=(/$66(0%/< The fuel pump come pre-installed on the frame of +26(&/$03 through the wall of the fuel line/hose to nearby objects. %8775(6672,1137$'$37(5 the generator set. The fuel pump iscapable of 40 725;3$1+($'6&5(: between the inches of lift. The 1</2&. fuel filter is installed ;++% This generator set is certified subject to fuel tank permeation pump and the fuel block. :$6+(5 )8(/&$3,1&+:$<9(17(' requirements. The supplied fuel system meets the following 7(7+(5('*$62/,1(21/<5(' retirements: )8(/287/(73257 '5$:1%< 5/9 A. A tethered or self-closing gas cap must be used. The fuel cap should incorporate a purge valve that stays seated up to a positive pressure of 3.5 PSI and a vacuum pressure of 0.1 PSI. B. Nonmetal gaskets used with fuel caps must be made from low-permeability materials. 7+,6'5$:,1*&217$,16 35235,(7$5< ,1)250$7,21%(/21*,1* 72/(5$1&( 72:,1&2 81$87+25,=('86(,6 02'(/ 352+,%,7(' $//',0(16,216,1&+ Gasoline Fuel Pump C. Fuel caps directly mounted to the fuel tank must have a surface area less than 3% of the total inside surface area of the fuel tank. Use the smallest inside cross sectional area of the opening on which the cap is mounted as the fuel cap’s surface area. &+. '%< 5 3$57 '$7( (1*$335 '$7( )8(/7$1.$66(0%/< Gasoline Fuel Filter RI Fuel Block WARNING Do not use low-pressure rubber hose for any part of the gasoline system. D. A strainer to prevent debris entering the tank is required. OPM-161/A '$7( '(&,0$/ 7,7/( '(*$1*8/$5 '5;; 8 INSTALLING THE FUEL LINE The following table gives you the recommended circuit breaker size specifications. See actual breaker for wire capabilities and torque specifications and restrictions. Engine-generator sets are properly adjusted before they leave the factory. Connecting a fuel supply with adequate supply volume is critical to reliable operation. This generator set has shipped with hoses that are approximately 215” long. The fuel line connected to the fuel pump should connect to the filter installed on the tank. The second fuel line should be connected to the fuel return port on the fuel tank. The fuel line connected to the fuel pump should connect to the filter installed on the tank. The second fuel line should be connected to the fuel return port on the fuel tank. When routing the fuel line a minimum bend radius of 3.0 inches is required for all hoses. Ensure that all hoses are protected from damage and are not exposed to foot traffic. Watts Voltage Phase CB AMP 28,000 120/240 1 100-150 28,000 120/208 3 100-120 28,000 120/240 3 90-100 28,000 277/480 3 40-50 28,000 346/600 3 30-40 The wire must be properly sized between the generator and the load. Use the table 310-16 of the National Electrical Code ANSI/NFPA 70. to properly size the wire to meet or exceed the amperage rating of the circuit breaker installed. U V W N If the hoses are too long for your application you can coil the excess or shorten them. If you replace the connector, you must use the connectors specified in the following paragraphs. All connectors must be automotive grade. Typically accepted automotive grade fuel line fittings incorporate quick connections with a rubber o-ring at the orifice. Winco uses 9C334 (WINCO part number 13-128) clamps on the high pressure hose and must be crimped with Oetiker pincers, model 1098i or model 1099i. Clamps must be positioned properly, after the clamp is crimped, a gap should be seen in the ear of the clamp, some spring back is normal. At start up check for leaks with a soapy water solution. If leaks occur replace the affected lines and connectors. Lug size 10mm CUSTOMER CONNECTIONS U Line 1 V Line 2 W Line 3 N Neutral ELECTRICAL CONNECTIONS NOTICE: CLASS 1 WIRING METHODS ARE TO BE USED FOR ALL FIELD WIRING CONNECTIONS TO TERMINALS OF A CLASS 2 CIRCUIT Ground NOTE: The symbol always indicates ground where shown. All wiring must be completed in accordance with the National Electric Code as well as any state and local codes. The optional DSE 7310 controller uses current transformers (CT) to monitor the amount of load on each leg of the generator. If the wires are routed through the CT the wrong direction it will result in a negative current readings on the controllers. This can be corrected by swapping the wires on the CT terminals in the generator end. Zip tie the wires to the CT walls after installation in order to prevent wire movement. You must pay particular attention to wire size requirement for the amperage of service you are dealing with. The table below provides you guidance on wire sizing based on both wire type and amperage. Wire amperages have been derated for 40° C ambient temperatures operation. WARNING: PERSONAL DANGER These units are shipped with a NEUTRAL TO GROUND BOND INSTALLED. If your system already has a neutral to ground bond, then you must run a separate ground lead to that location and UNBOND THE JUMPER IN THE CONNECTION PANEL. For additional information, refer to the current National Electrical Code on grounding. GENERATOR CIRCUIT BREAKER This unit DOES NOT come with a circuit breaker. The circuit breaker will provide overload protection for the generator. 9 OPM-161/A WARNING: EQUIPMENT DAMAGE Unbalanced loads can lead to overloading of individual winding groups and high voltage swings. This may result in equipment damge if the unbalance is left uncorrected. WARNING: EQUIPMENT DAMAGE When installing a three phase 240 Volt system, be sure you know which lead is high voltage ‘wild’ leg (208 Volt to neutral). The generator normally carries the high voltage on the G2 lead. GROUNDING LOAD BALANCING The following diagram represents this generator when configured in single phase. A and B represent the 120V output of this generator. Up to half of the rated capacity can be drawn from the L1 to N or L2 to N. This generator’s full capacity can be drawn from C by connecting the load at 240V from L1 to L2. Remember that power from C equally reduces the amount of power available at both A and B and vice versa. L1 - (HOT) A 120 VOLTS NEUTRAL C 240 VOLTS B Proper grounding of your generator is application dependent. Carefully evaluate your planned use of your generator to understand which grounding you require. If you are not sure what to do, contact a competent professional to assist you. The NFPA 70 250:34-35 are good technical references. VEHICLE-MOUNTED GENERATOR Your WINCO generator ships with a bonded neutral. When mounted to a vehicle to safely distribute power it is necessary that the generator frame is bonded to the vehicle frame. The generator should only supply equipment that is cord and plug connected through customer installed receptacles mounted on the generator or the vehicle. PERMANENTLY INSTALLED GENERATORS L2 - (HOT) The following diagram represents the generator when configured in 3-phase. A, B, and C represent the L to N voltage output of this generator. Up to a third of the rated capacity can be drawn from L1, L2, or L3 to N. This generator’s full capacity can be drawn from D by connecting a 3-phase load to all three legs. Remember that power taken from D equally reduces the amount of power available to both A, B, and C and Vice versa. TRANSFER SWITCH NOTICE For full service switching of the entire load, the ATS must be ‘SE’ (Service Entrance) rated or must have a properly rated fusible disconnect installed before the ATS to protect the contacts. D L1 (HOT) NEUTRAL This WINCO portable generator ships with a bonded neutral. NFPA 70 refers to this as a “separately derived system.” When connecting it to a building a transfer switch specifically designed for GFCI and bonded neutral generators is required or the ground or the neutral to ground bond must be broken and the panel relabeled. A C B L3 (HOT) L2 (HOT) When connecting loads to the generator, make sure you balance the amount of load on each leg. Equipment, like motors,evenly load on each leg (two leg for 1-ph and three legs for 3-ph) and do not require any special considerations for load balancing. When applying 1-ph loads to 3-ph systems, care must be taken to ensure that each leg is equally balanced. A sign of unbalanced loads may be trouble with volatge regulation. The generator’s nameplate current ratings are calculated using a 0.8 power factor (PF). Many loads are applied at 1.0 PF, reducing the total amperage available. Use the following formula to calculate the current required for your loads. Amps = OPM-161/A WARNING: FIRE HAZARD All wiring must be done by a licensed electrician, and must conform to the National Electrical Code and comply with all the local codes and regulations. Check with the local authorities before proceeding. Watts (1.732 x V x PF) INSTALLATION NOTES: Because of many different types of service, feeder and distribution equipment, no specific wiring instructions can be provided. It is recommended that only copper wire be used. In all cases it is essential that while the load is connected to the generator, there can be absolutely no feedback from the generator to the power line or the power line to the generator. When properly installed, the normal ATS Control and safety system will eliminate all paths and feedback. To wire the automatic transfer switch into existing wiring, first determine which circuits will be on the emergency load circuit. If the entire load is transferred, the transfer switch can be wired directly after the meter and the service entrance, providing the service entrance ampere rating is within the transfer switch’s rated capability. 10 If only specific circuits are to be powered under emergency power failure conditions, an additional distribution panel designated “emergency distribution panel” must be installed. and the starter circuit. Opening any switch in the series prevents the engine from cranking or from receiving fuel to run. Battery Battery + Ground Ground Remote Start Remote Start + Emergency Stop Emergency Stop Battery Charge Fail 4B (DSENET) 4A (DSENET) SCR (DSENET) All selected emergency circuits are removed from main distribution panels and installed in the emergency distribution panel. The ATS is then installed between the main panel and the emergency distribution panel. Suggested circuits: freezer, refrigerator, furnace, emergency lights, sump pump, emergency outlet circuits, etc. Total running load must not exceed generator rating. DC WIRING E-Stops This wiring information is for the DSE7310 controller. All communication and DC wiring should be run in separate conduit from AC wiring. To install the wires, reference the following picture. Use a small flat head screwdriver to push the release spring inside the square hole (A). While the release is being pushed, insert the wire into the larger circular hole (B). Remove the screwdriver to secure the wire into place. B A REMOTE START The DSE7310 is able to start the generator when it receives a remote signal from any dry contact. This makes the system compatible with a wide range of control mechanisms including two-wire start automatic transfer switches. When the contact closes the controller will automatically start. When the contact is opened the generator will go through a cool-down cycle and turn off. Connect the remote start leads to the Remote Start + and Remote Start - terminal blocks in the door behind the DSE 7310 controller. To wire additional emergency stop switches first remove the orange jumper between the two Emergency Stop terminal blocks. Failure to remove the jumper will prevent the remote switches from working properly. Add wires between the terminal block to the new switch(s). The switches must be wired in series for proper function. Test each e-stop after wiring to ensure they function properly. SERIAL COMMUNICATION DSE provides a series of remote accessories that can help provide useful information to operators. These accessories communicate over the DSE Net. Terminal blocks are wired to the distribution panel to aid in installation. Follow the instructions included with each accessory. The generator controller can communicate with a variety of controls and monitoring systems, including RS232 and RS485. The ports are wired onto the back of the DSE7310. In order to finalize communication the program will need to be adjusted using the free DSE configuration software to enable the commutation. Contact Winco service for a list of register values. INSTALLING THE BATTERY CAUTION In the following battery installation procedure, check to be sure the engine control is in the “stop” position. This should be your last step before initial start-up. A customer supplied 12 Volt battery is required to complete the installation. Installation of the highest CCA rated battery, within the correct BCI group, will increase cold weather starting performance. Battery Battery + Ground Ground Remote Start Remote Start + Emergency Stop Emergency Stop Battery Charge Fail 4B (DSENET) 4A (DSENET) SCR (DSENET) BATTERY REQUIREMENTS Two-Wire Start Hook-Ups Model Voltage BCI Group PPG28F4 12 24 Min. CCA Rating 650 WARNING: EQUIPMENT DAMAGE This unit is12 Volt and is negative ground. Permanent damage will occur if they are connected to a 24 Volt system or a positive ground system. If you are using the truck batteries to start these units, you may have to disable the charging system to keep it from interfering with the vehicle charging system. E STOPS In some applications additional emergency stops may be desired or necessary. The controller has terminals designed allowing the addition of multiple remote emergency stops. E-stops must be normally closed to work properly in this system. The e-stop circuit supplies power to fuel solenoid 11 OPM-161/A Installation and servicing of batteries must only be preformed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries. When installing or replacing batteries, use the proper group/size starting battery. The battery should be a maintenance-free lead acid design. Deep cycle batteries will not work for this application. CAUTION: PERSONAL DANGER NEVER dispose a battery in a fire. The battery is capable of exploding. DO NOT open or mutilate the battery. Released electrolyte is known to be harmful to the skin and eyes and to be very toxic. These engine-generator sets are all NEGATIVE ground. Be very careful not to connect the battery in reverse polarity, as this may short circuit the battery charging system on the engine. CAUTION A battery presents a risk of electrical shock and high short circuit current. The following precautions must be observed when working with batteries: 1. Remove watches, rings, and other metal objects. 2. Use tools with insulated handles. 3. Check both the battery cable ends and the battery posts to be sure they are free of corrosion. 4. Always connect the battery positive cable first and then connect the battery negative cable. When removing the battery cables from the battery, reverse the procedure, disconnect the negative first and then the positive cable. 5. Be sure all connections are tight and coat the terminals and cable ends with dialectic grease. WARNING The electrolyte is diluted sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following precautions must always be taken. 1. Always wear full eye protection and protective clothing. 2. Where electrolyte contacts skin, wash off immediately with water. 3. If electrolyte contacts the eyes, flush thoroughly and immediately with water and seek immediate medical attention 4. Spilled electrolyte is to be washed down with an acid neutralizing agent. A common practice is to use a solution of one pound of bicarbonate of soda (baking soda) to one gallon of water. The bicarbonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried. DANGER: EXPLOSIVE FIRE RISK 1. Never smoke when near batteries. 2. Do not cause a flame or spark in the battery area. 3. Always discharge static electricity from your body before touching batteries by first touching a ground metal surface. OPM-161/A SERVICING BATTERIES Batteries used on these units may, over time, lose water. This is especially true if you are using a trickle charger to maintain your battery. When refilling the battery with water, use only distilled water. Tap water will shorten the service life of the battery. Never fill the battery above the fill line. Over filling above the upper level line may cause the electrolyte to overflow, resulting in corrosion to the engine or nearby parts. Immediately wash off any spilled electrolyte following the procedure above. NOTE: Always make sure that a new battery is fully charged before installing it on a generator set. Failure to do so can cause damage to the engine control module in the generator set. All connections must be clean and tight. Check the electrolyte in the battery periodically to be sure it is above the plates. Never allow the battery to remain in a discharged condition. BATTERY CHARGER A three-stage, on-board marine battery charger is provided standard on this unit. The charger is a 1.5 amp dual use maintainer and charger designed to keep your batteries fully charged by maintaining them automatically. Make sure all DC battery connections are tight and clean. Follow battery manufacturer’s recommendations. This charger is mounted under the customer connection on the control side of the generator. The charger will need to be plugged to a customer’s power source, using a customer supplied heavy duty, UL approved extension cord. The receptacle is to be powered by a GFCI circuit and installed in accordance to the US National Electric Code. It is suggested that this circuit be fused to 20 Amps. Low/Charge Mode: The illuminated blue power LED and red low/charging LED. This indicates the Low/Charge mode is in process. When completed the RED Low/Charge LED will turn off. Auto Maintain Mode: The illuminated Green auto maintain LED. This indicates your 12volt battery is fully charged. During short or long term storage periods, Auto Maintain (Energy Saver) mode will monitor and auto maintain a battery only when needed to maintain a full state of charge. This feature significantly reduces AC Power consumption, lowers operating costs and maximizes reserve power performance. BLOCK HEATER The block heater on this unit is a 1500 watt heater and can use the same 20 Amp GFCI fused circuit. This circuit will terminate on the 120 Volt terminal block mount in the customer connection cabinet. The engine block heater installed on this unit should also be plugged into this receptacle. The block heater is thermostatically controlled when plugged in will maintain the engine coolant temperature between 100 and 120 degrees F. 12 STARTING PROCEDURE CAUTION For the first 10 seconds of operation all of the oil, coolant, and electrical shutdowns are disabled. This is enough time to cause catastrophic damage to the equipment if the pre-start checklist is not properly completed and proper maintenance isn’t consistently followed. its seat. Remove the dipstick again and check the level. IMPORTANT The O2 sensors on this engine require 1-2 hours of operation to break in. Until those hours are completed the engine may show fault DTC1155. Before starting the engine, check the coolant level in the radiator. If it is low, refer to Refilling Coolant in the Maintenance section of this manual. The radiator should be filled to about 1 inch below the filler neck. For additional information on engine coolant requirements, see engine manufacturer’s maintenance instructions. LUBRICATION Before starting the engine, check the oil level in the crankcase. If it is low, refill to the full mark with the proper weight/grade of oil as recommended by the engine manufacturer’s maintenance instructions. The necessity of using the correct oil, and keeping the crankcase full, cannot be over emphasized. Failure to use the proper oil and keep the crankcase properly filled will cause excessive engine wear and shorten its useful life. 3. If level is low, unscrew the oil cap and refill with suitable oil using the previous table. COOLANT PRE-START CHECK LIST There is a Pre-Start & Warranty Form that must be filled out by an Authorized WINCO Service Center. After completing the checklist, the engine-generator set is ready for initial start-up. WARNING: EQUIPMENT DAMAGE Before attempting to start this unit, complete your pre-start checklist and ensure the generator mainline circuit breaker (if installed) is in the proper position prior to starting. Starting this unit without it properly connected can cause serious personal injury or equipment damage. Winco recommends our 5W-30 fully synthetic heavy duty engine oil to give you maximum cold weather protection while maintaining excellent performance in warmer weather. We have partnered with a national lubrication oil manufacturer to give you access to Winco private branded premium oil available at comparable prices to conventional oils. See your dealer for additional information. DO NOT jump start these engine-generator sets. Starting these units on a low battery or jump starting them will cause damage to the engine control module. MANUAL START PANEL (Standard) This generator comes standard with a manual start control panel. The battery is wired to the E-Stop first. The unit will not start if the E-Stop is pushed in (the off position) dip stick oil cap filler port There are glow plugs installed and controlled by the engine’s ECU. If the coolant temperature falls beneath a set temperature, the engine will automatically engage the glow plugs. A CAUTION: PERSONAL INJURY Only check oil when the engine is not running and is at a low temperature in order to avoid the risk of burns. 1. Remove the dipstick and ensure the oil level is between the Min and Max limits. 2. If it is difficult to assess the level of the oil, clean the dipstick using a clean cloth and then put it back into E B F C D H G A. E-STOP Pushed In - Off Pulled Out - On The unit will not start if the E-Stop is pushed in the off position. 13 OPM-161/A B. RUN/STOP ROCKER SWITCH Run - Engages the engine. Stop - Turns unit off. C. START ROCKER SWITCH Start - Hold till engine starts D. DISPLAY VOLTAGE SWITCH Move the switch to the line you want to view on the voltmeter. RESISTOR There is a resister installed inside the harness. If a fuel tank is installed in the field, remove the resistor and connect a one watt fuel sender with a range from 33 to 240 ohms. For units that came assembled with a fuel tank, the resister can be found in side the panel, loose. DSE7310 MKII (Optional) CAUTION If the DSE7310 is being replaced with a manual start panel, the voltage on the regulator will need to be adjusted. E. HOUR METER The hour meter will start when the run/stop rocker switch is in the RUN position. Note: If left in the RUN position for a long period of time, it will time-out after an hour of no use. This will add an hour to the hour meter. F. WARNING ICON GAUGE UPPER LEFT - POSITION #1 EGR (Exhaust Gas Recirculation) Inducement Level ! UPPER RIGHT - POSITION #2 PMCAT & HEST Particulate Matter Catalyst or High Exhaust System Temperature LOWER LEFT - POSITION #3 Engine Diagnosis Code STOP/RESET - This button places the module into its Stop/Reset mode. This will clear any alarm conditions for which the triggering criteria have been removed. The fuel supply de-energizes and the engine comes to a standstill. Should a remote start signal be present while operating in this mode, a remote start WILL NOT occur. MANUAL MODE - This button places the module into its Manual Mode. Once in Manual Mode, the model responds to the Start button to start the generator and run it off load. LOWER RIGHT - POSITION #4 Low Fuel Level Low fuel lamp will be steady when fuel level has reached 20% or less. It will flash when the fuel level is 5% or less. The engine will shut down if the fuel level is at 5% or less. In the event that the upper left and upper right icons are flashing, contact your local Service Center for repair. H. FORCED REGEN BUTTON Hold to force a manual regen. The button will have to remained pressed until the regen has completed. A forced regen should only be performed by a service technician. START - Pressing this button from STOP/RESET will start the engine and run the load. AUTO MODE - This button places the module into its Auto Mode. This mode allows the module to control the function of the generator automatically. ALARM/LAMP TEST - This button silences the audible alarm in the controller, deactivates the Audible Alarm output (if configured) and illuminates all of the LEDs on the module’s face as a lamp test function. MENU NAVIGATION - Used for navigating the instrumentation, event log, and configuration screens. A small rocker switch is located on the underside of the engine control cabinet. STARTING Move the rocker switch to the RUN position. The engine lights will light up on the icon gauge. The engine light will still be present until the engine has started. Hold down the START switch until engine starts. Wait five seconds for the engine to reach speed before proceeding. Note: The ECU may override the start command if the start switch is held for too long. STOPPING To turn off the unit, move the rocker switch to STOP. WARNING: EQUIPMENT DAMAGE Always make sure the generator runs under no load for five minutes before stopping to allow the engine and components to cool down. Don’t use the E-Stop to shut down the generator unless there is an emergency. On gaseous models, the engine timing is controlled by the ECU on the engine and you need to tell it what fuel you want to operate on; LP or NG. On diesel models, this switch has been disconnected and will do nothing. OPM-161/A 14 PROTECTIONS When an alarm is present, the common alarm LED, if configured, will illuminate. The LCD display will show an icon to indicate the failure. WARNINGS Warnings are non-critical alarm conditions. They do not affect the operation of the generator system, they serve to draw the operator’s attention to an undesirable condition. Warning alarms are self-resetting when the fault condition is removed. The icon will appear steady in the display. 3. During manual operation, the load will not normally be applied to the generator. But caution must be used, if the line power should fail or be turned off the transfer switch during manual operation the load may be applied to the generator. With the engine running smoothly check the no load voltage and frequency on the digital display. The voltage should match the nameplate and a frequency of 59.5 to 60.5 hertz (Hz). If you have the proper voltage at the generator the next step is to check the voltage at the generator terminals in the Automatic Transfer Switch. The voltage between the G1 and the G3 terminals should be the same as it was on the generator front panel. The voltage should also be checked between the hot terminals (G1 and G3) and the G-N to be certain of a balanced voltage output and a solid neutral connection. The voltage between G1 and G-N should be about 120 volts AC (277 on 480 units). The same approximate voltage should be found between terminals G3 and G-N (120 volts AC). SHUTDOWN Shutdowns are critical alarm conditions that stop the engine and draw the operator’s attention to an undesirable condition. Shutdown alarms are latching. The fault must be removed and the STOP/RESET button pressed to reset the module. The icon will be flashing in the display. AUTO MODE To activate the automatic start mode you will just need to depress the AUTO button, the LED indicator beside the button confirms that the unit is in automatic mode. On three phase panels the G2 voltage level should also be checked. ON 240 VOLT (DELTA) SYSTEMS BE SURE YOU KNOW WHERE THE HIGH VOLTAGE “WILD” LEG IS. IT MUST BE IN THE SAME LOCATION ON THE LINE SIDE AS IT IS ON THE GENERATOR SIDE. (i.e. if it’s on L-3 on the line side it must be on G-3 on the generator side. Also on three phase systems make sure that the rotation is the same on the generator as it is on your line power. Failure to insure proper rotation will cause three phase motors to spin backwards possibly damaging them. To test the Automatic Transfer Switch, follow the instruction on the operator’s manual that came with the transfer switch. If you get a fault during the initial start up or prior to start up, it is most likely a false warning light. Simply reset the ATS to start over. Once you have completed testing of the ATS, be sure you ALWAYS leave the system in the standby mode,unless servicing the unit. For standby operation, press the AUTO button on the front of the control. The green light should light up next to the AUTO button. NOTE: For setting the exerciser circuit, for all ATS, see the operator’s manual shipped with the ATS. MANUAL MODE 1. Press and release the MANUAL MODE button. The small LED light next to it should come on. NOTICE: If for any reason during the check out procedure the voltage and frequency are not correct, depress the STOP/RESET button and correct the trouble before proceeding. 4. Stopping - There are two ways to stop the unit when it is in the manual mode. Pressing the STOP/RESET button will stop the unit immediately. Pressing the AUTO mode button will stop the unit but only after the cool down timers have timed out and there is no remote start signal being sent to the unit. WARNING: EQUIPMENT DAMAGE Note: There is no start delay in this mode of operation. 2. Press and release the green START ENGINE button. The DSE 7310 will send two signals to the engine. The first signal wire #21 will engage the fuel solenoid, the second wire, #22, will engage the starter on the engine. At this point the DSE 7310 will start the cranking cycle (10 seconds on and 10 seconds off). Note: Wire #93 is energized to turn on the glow plugs for 15 seconds first and then the starter and fuel solenoid are engaged. If the engine fails to start during this cranking period, the starter motor is disengaged and goes into a rest mode after which a second attempt is made to start the engine. Should this sequence continue through 3 cranking cycles the start sequence will be stopped and the display will show ‘FAILED TO START’. Always make sure the generator runs under no load for five minutes before stopping to allow the engine and components to cool down. Don’t use the E-Stop to shut down the generator unless there is an emergency. CONTROL POWER The DSE7310 controller consumes small amounts of battery power when it is in use. The controller comes with a power switch that disconnects battery power when it is not in use. The switch is designed with a safety relay that prevents it from removing power to the controller while the generator is operating. If the switch is turned off while the engine is running it will continue operating until the engine shuts down and then the controller will power down. This switch should be used when the generator is not going to be used over the course of several days and the generator is not connected to a battery charger. 15 OPM-161/A A solar charger kit is the easiest way to always maintain the battery during storage in mobile applications. The supplied battery charger can be plugged in to an extension cord on mobile applications. OPERATING CONDITIONS NORMAL OPERATION This generator-engine set needs load and should not idle for long periods of time. If the generator application is for emergency standby the generator should be exercised at least monthly ideally under load. Load banking the generator at least annually will help keep the engine in good condition. HARSH ENVIRONMENTS OPERATIONS Some applications require the generator to operate in harsh environments. One of the most common hazards are extremely dusty conditions. In harsh conditions it is often necessary to take additional steps to keep the equipment clean and operating at its peak. Maintenance intervals on lubricant and filter changes may need to be shortened. An oil quality testing program can also provide early warnings or oil degradation. Efforts may need to be made to reduce the amount of dust and debris entering the housing and generator components. COLD WEATHER OPERATIONS The minimum starting temperature with block heater is -13°F. The degree of fluidity of the engine oil may be reduced at low temperatures due to the separation of the paraffin. This results in the filters becoming clogged. Oil companies must respect these standards, which provide for the distribution of fuels adapted to the climatic and geographical conditions in various countries. This generator-engine set needs load and should not idle for long periods of time. If the generator set will be run in extremely cold environments it may be beneficial to provide means to reduce air circulation to increase the temperature of the enclosure. Inspect the hoses regularly during cold operation looking for signs of freezing. If the line freezes it will cause pressure to build in the crankcase and may cause an engine seal failure. If the engine operates below optimal temperatures for long periods of time damage may occur. OPM-161/A 16 MAINTENANCE WARNING: PERSONAL INJURY/EQUIPMENT DAMAGE Place controller in manual mode, e-stop applied first. If an auto start signal comes on during maintenance, it may result in injury, death and equipment damage. CHANGING OIL FILTER CHANGING THE OIL dip stick oil cap filler port The filter must be replaced when the lubricant oil is changed. Only use filters with a filtering degree equal to the original filter. CAUTION: PERSONAL INJURY Only change oil when the engine is not running and is at a low temperature in order to avoid the risk of burns. WINCO pipes the oil change to the outside for convenient maintenance. Winco recommends our 5W-30 fully synthetic heavy duty engine oil to give you maximum cold weather protection while maintaining excellent performance in warmer weather. We have partnered with a national lubrication oil manufacturer to give you access to Winco private branded premium oil available at comparable prices to conventional oils. See your dealer for additional information. CAUTION: PERSONAL INJURY Only change oil when the engine is not running and is at a low temperature in order to avoid the risk of burns. 1. Remove the oil cap to vent the engine crankcase and allow the oil to drain more easily. 2. Place a drip pan or suitable container for catching the oil . WINCO has supplied a valve on the skid frame to hook a customer supplied 5/8” hose to conveniently run the oil to the drip pan. 3. Drain the oil. 4. Once the oil has fully drained, close the valve. 5. Top-off through the filler port using lubricant oil with the suitable oil table in the LUBRICATION section of this manual. 1. Use an oil filter wrench to unscrew and remove the oil filter. 2. Lightly coat the gasket on the new oil filter with engine oil. 3. Install the new engine oil filter manually by screwing on new oil filter canister until sealing ring abuts the filter head and tighten a further 1/2 turn. Do NOT use a strap wrench or similar tool to tighten the filter canister. 4. Warm up the engine by running it for 5 minutes and check for any oil leaks. 5. Recheck the oil level using the dipstick. 6. Add engine oil to engine oil filler port as needed until the level is between the maximum and minimum lines shown on the dipstick. FUEL FILTER Remove the nuts and bolts to remove the clamps around the filter. You will need a fuel disconnect tool (Napa part number SER 3321) to remove the plastic clips on the valves. plastic clip 6. Use the dip stick to ensure the level of oil does not exceed the “MAX” limit. 7. Insert the dipstick and close the lubricant oil cap. 8. Dispose of oil in accordance to local codes. DO NOT dispose or allow oil to seep into the ground or sewer systems, doing so will cause environmental damage. NOTE: There two fuel filters, one on the frame, one on the fuel tank. Remove the nuts and bolts to remove the clamps around the filter. 17 OPM-161/A FILLING COOLANT CAUTION: PERSONAL INJURY Never remove the pressure cap while the engine is running or if cooling system is hot. Scalding coolant or steam can escape, which can cause serious burns. CAUTION: EQUIPMENT DAMAGE Never use a cold coolant mixture to top-up the radiator of a hot engine if the coolant level is very low; this could cause serious engine damage. 4. After draining the engine coolant, flush the radiator and engine block with water to remove any rust, scale and contaminants. Then reinstall and tighten the drain plug. 5. Fill the coolant reservoir tank first. 6. Locate the nipple (1) on the coolant manifold. Fill the manifold. Stop when the coolant is just over the fins in the radiator. Replace cap. If the liquid withdrawl is installed, reconnect the hose. 1 7. Fill the remaining amount of coolant needed in the radiator. Replace cap. 1. Engine should be cooled down to at least 110˚F 2. Ensure the radiator plug located at the bottom of the radiator and the plug on the engine block are secure. 2. Turn the filler cap 90˚ counter-clockwise, pause to allow the pressure to drop. Remove the cap (1) and slowly pour the coolant into the radiator until it is even with the lip of the filler port. Ensure no air bubbles develop. Note: Following these instructions will lessen the chances of getting air pockets. Pouring all of the coolant into the radiator only greatly increases the chance. 8. Run the engine to check for leaks. CLEANING RADIATOR The surfaces of the radiator come into contact with the outside air and can be subject to deposits and impurities. Clean in accordance to the maintenance schedule with compressed air or steam. Remove dirt or foreign material with a soft brush or cloth. 3. Reinstall radiator cap. CAUTION: EQUIPMENT DAMAGE Never use a cold coolant mixture to top-up the radiator of a hot engine if the coolant level is very low; this could cause serious engine damage. CHANGING COOLANT CHANGING AIR FILTER The engine performance is adversely affected when the air cleaner element is clogged with dust. WARNING: EQUIPMENT DAMAGE Never operate the engine with the air cleaner element removed. This may allow foreign material to enter the engine and damage it. Do NOT remove filter while engine is running. Engine coolant contaminated with rust or water scale reduces the cooling effect. Even when extended life engine coolant is properly mixed, the engine coolant gets contaminated as its ingredients deteriorate. Drain, flush and refill the cooling system with new coolant every 1000 hours or once a year, whichever comes first. CAUTION: PERSONAL INJURY Only proceed when the engine is not running and is at a low temperature in order to avoid the risk of burns. 1. Loosen the cap on the radiator. Once all of the pressure is released, fully remove the cap. 2. Remove the drain plug at the bottom of the radiator and drain the coolant into an approved container. Reinstall plug. 3. Remove the coolant drain plug from the engine block. OPM-161/A 1. Unlatch and remove the air cleaner cover (1). 2. Remove the element (2). 3. Blow air (Figure 13, (3)) through the element from the inside out using 42 - 71 PSI compressed air to remove the particulates. Use the lowest possible air pressure to remove the dust without damaging the element. 18 4. Replace the element with a new one if the element is damaged, excessively dirty or oily. 5. Clean inside of the air cleaner cover. 6. Reinstall the element into the air cleaner case (4). Note: If there is a red line (2) in the outer element, reinsert the element until the overlap position of red line and end face of the air cleaner case. 7. Reinstall the air cleaner cover making sure you match the arrow (5) on the cover with the arrow on the case (6). 8. Latch the air cleaner cover to the case. STORAGE PREPARING THE ENGINE FOR A LONG PERIOD OF INACTIVITY In the case of a planned period of inactivity that lasts longer than one month, to prevent the interior parts of the engine and some components of the injection system from oxidizing, prepare the engine as follows: One Month 1. While the engine is running, treat upper cylinders by spraying engine fogging agent into the air intake for about two minutes. Open throttle for short bursts of speed, shut off engine and allow it to come to a stop while continuing to spray into air intake. non-hygroscopic material. Mask off all area to be used for electrical contacts. 9. Make sure all surfaces are dry, and then spray all taped openings, all engine accessories including ignition wiring, and all exterior surfaces of engine with Insulation Compound. RETURNING ENGINE TO SERVICE 1. Perform the Daily Checks. 2. The engine should be pre-oiled before startup. Crank the engine, leaving the fuel system shut off so the engine will not start, for 15 seconds. Then pause for 30 seconds. Repeat the procedure until you have cranked the engine for a total of one minute. This will circulate the oil in the engine’s lubrication system. 3. Start the engine. Allow the engine to idle for approximately 15 minutes while you check for: • Proper oil pressure • Fuel, engine oil, or coolant leaks • Proper operation of the indicators and/or gauges. 4. Avoid prolonged operation at minimum or maximum engine speeds and loads for the remainder of the first hour of operation. 2. Leave spark plugs in holes or seal spark plug holes with suitable threaded metal plugs and cover all openings into engine with dust-proof caps or shields. 3. If engine is less transmission, spray flywheel and ring gear with mixture of one part recommended engine oil, and one part Stoddard Solvent or equivalent. 4. Check coolant protection. Store indoors in dry area. Infinite period 1. Perform the next Preventive Maintenance procedure. For example, if there are 10 hours remaining before the 250 hour maintenance, you should do the maintenance before you place the engine in storage. 2. Drain crankcase completely and refill with recommended engine oil. 3. Run engine until completely out of fuel. 4. Check coolant protection 5. Disconnect and remove the battery. 6. Clean exterior surface of the engine. 7. Leave spark plugs in holes or seal spark plug holes with suitable threaded metal plugs. 8. Seal all openings in engine and accessories with 19 OPM-161/A VOLTAGE REGULATOR The following is a list of connections on the AVR. These have been factory set and other than voltage adjustment, should never be changed. AS540 AVR 2 9 4 6 1 3 8 7 5 1. VOLTS - Adjust generator output voltage. Clockwise to increase voltage. 2. LINK: HAND TRIMMER 1-2: NO TRIMMER NONE: TRIMMER FITTED Adjust alternator output voltage Clockwise to increase voltage by AVR voltage adjustment. 3. STABILITY - To prevent voltage hunting. Clockwise to increase dampening effect. 4. LINK: SUPPLY Link: 110V/120V None: 240V Select AVR supply source. 5. UFRO - Under Frequency Roll Off Clockwise decreases ‘KNEE’ point. 6. SWITCH - Select alternator frequency for UFRO SWITCH LEFT: 60Hz SWITCH RIGHT: 50Hz 7. LED Indicator Light - LED light on in UFRO or O/EXC condition. 8. O/EXC - Adjust over-excitation trip. Clockwise to increase trip voltage. 9. LINK: SUPPLY 8-Z2: Main Stator None: Auxiliary Winding Select AVR supply source. OPM-161/A 20 MAINTENANCE SCHEDULE DAILY Check engine oil Check engine coolant level Visually check for oil, fuel, or coolant leaks Check all instruments, controls, and warning lights AFTER FIRST 50 HRS Check engine oil Check engine coolant level Visually check for oil, fuel, or coolant leaks Check hoses/pumps for leaks. Visibly inspect wiring EVERY 100 HRS Check engine oil Check engine coolant level Visually check for oil, fuel, or coolant leaks Check hoses/pumps for leaks. Visibly inspect wiring EVERY 200 HRS Check engine oil Check engine coolant level Check gasoline fuel filter element, replace if needed Check dry fuel filter, replace if needed Visually check for oil, fuel, or coolant leaks Check hoses/pumps for leaks. Visibly inspect wiring Check condition & adjust tension in drive belts Check fuel filter element, replace if needed Check dry fuel filter element, replace if needed EVERY 400 HRS Check engine oil Check engine coolant level Visually check for oil, fuel, or coolant leaks Check all instruments, controls, and warning lights Check hoses/pumps for leaks. Visibly inspect wiring Change engine oil & filter Check condition & adjust tension in drive belts Check fuel filter element, replace if needed Check dry fuel filter element, replace if needed Change air filter Clean, adjust, test, relpace (if needed) spark plugs Check nuts & bolts for tightness EVERY 800 HRS Check engine oil Check engine coolant level Visually check for oil, fuel, or coolant leaks Check hoses/pumps for leaks. Visibly inspect wiring Change engine oil & filter Check condition & adjust tension in drive belts Check fuel filter element, replace if needed Check dry fuel filter element, replace if needed Change air filter Clean, adjust, test, relpace (if needed) spark plugs Check nuts & bolts for tightness Inspect PCV valve Clean PCV hoses, tubes & fittings EVERY 4 YEARS Clean coolant filler cap, replace if needed Note: Some operating conditions may require more frequent maintenance intervals. 21 OPM-161/A TROUBLE SHOOTING TABLES Problem Possible Causes Unit will not crank when power fails Digital genset not in AUTO Transfer control switch not in AUTOMATIC position Incorrect wiring between ATS and genset Defective control relay in ATS Fuse(s) blown in the DSE 7310 Defective DSE 7310 Loose or dirty battery terminals Defective starter Defective start solenoid Low/dead battery Engine won’t crank Low/dead battery Blown DC fuses Defective DSE 7310 Defective key switch Loose or dirty battery terminals Defective starter Defective start solenoid Locked up engine genset Defective engine harness Improper battery voltage to start solenoid, fuel pump, or fuel solenoid E-Stop in off position Fuel filter element may be clogged, inspect and/or replace Engine cranks but will not start Improper fuel delivery to the unit Fuel supply shut off Fuel tank empty Air in the fuel system Engine fuel solenoid has not opened Defective fuel pump Defective fuel solenoid Defective engine harness Improper battery voltage to fuel pump or fuel solenoid Engine starts, then stops and alarm light comes on Engine oil pressure is low Engine has high water temperature Engine has overspeed Engine has gone into overcrank No output from AC generator Loss of speed signal Loss of run signal Fuel filter element may be clogged, inspect and/or replace Engine will not come up to speed after it starts Insufficient fuel volume getting to the unit 1. Too small of fuel line 2. Fuel racks not open properly AC short in generator components ATS will not transfer to Emergency Supply (generator) No AC generator output Defective ATS control board. See ATS manual Circuit breaker open or defective ATS will not re-transfer to normal power Proper power line not available at line terminals in ATS panel Defective ATS control board. See ATS manual No AC output from generator Defective diode Defective voltage regulator Defective rotor Defective stator Defective exciter rotor Defective exciter stator AC short in the output leads Defective/open generator output breaker Wiring error OPM-161/A 22 ENGINE HARNESS SCHEMATIC 6 1& 6 1& ,51 ' $ 3 1 )8(/62/,12,'6 5(9 $ (1*,1( +$51(66 )8(/ &211(& 3/8* 237,21$//2:&22/$176(1625 3/8* (1*,1( (&8 67$57&200$1' )8(/6(/(&7 ,*1,7,21 &$1/2: &$1+,*+ / + '5$:1%< 00/ 72/(5$1&( 7+,6'5$:,1*&217$,16 35235,(7$5< ,1)250$7,21%(/21*,1* 72:,1&2 81$87+25,=('86(,6 352+,%,7(' 23 OPM-161/A :(,*+7 0$7(5,$/ 02'(/ 6(( 366 ENGINE CONTROLS POWER DISTRIBUTION Power Distribution MSG-425 Engine Controls OPM-161/A 24 STARTING SYSTEM 25 OPM-161/A IGNITION SYSTEM Ignition System MSG-425 Engine Controls 26 OPM-161/A CHARGING SYSTEM MSG-425 Engine Controls Charging System 27 OPM-161/A MSG-425 Engine Controls 08 - 19 MSG-425 Engine Controls Engine Controls - Sensors (2 of 2) 28 OPM-161/A Engine Controls - Sensors (1 of 2) SENSORS ACTUATOR/DATA LINK CONNECTOR Engine Controls - Actuator / Data Link Connector (DLC) 08 - 22 OPM-161/A 29 DRY FUEL DEPR MSG-425 Engine Controls Engine Controls - Dry Fuel DEPR 08 - 23 OPM-161/A 30 MANUAL START PANEL WIRING DIAGRAM 31 OPM-161/A )86( $ 56 * * * 1 )86($ )86($ )86($ )66 ',*,7$/,13876 02'8/(0.,, 1250$//< &/26('5(/$< 287387& )/(;,%/(6(1625 8 9 : 1 / / / *(192/76 )/(;,%/(6(1625 &22/$177(036(1625 2,/35(6685(6(1625 &7 &7 &7 &7 &20 *(1&855(17 $1$/2*8(,1387&20021 /6 /6/6 16 9( %$77(5< 9( 36 (66 67$57 &+$5*($/7 ',15$,/7(50,1$/%/2&.6 $6 '&2873876 25$1*( %$77(5<9( $7 6&5 038 $ 6&5 '6(1(7 % / 6&5 (&8 + 6&5 &$1+ &$1/ $ 56 6&5 % 86% 352*5$00,1* 3257 :+,7( /2:&22/$1702'8/( )86($ 7(50,1$/%/2&.-803(56 6+2:1$%29(25%(/2: 7+(,5&255(6321',1*7(50,1$/6 ,51 '(6&5,37,21 '$7( %:= %< '5' $33 ' 5(9,6,216 5(9 '5' 25,*,1$/ '5' 3 '5' $ %:= %:= %:= 83'$7('$)7(53,/27 '$7( &+. '%< '$7( '5' (1*$335 '&&211(&725 $&&211(&725 83'$7(':,5(21&21752//(5$872$: * * * 1 6:$33(')251(:%/$&.3$57 % ' & 9$5 .ƺ 6&5 &$1/ &$1+ %:= 5 3$57 '$7( '(&,0$/ 7,7/( '(*$1*8/$5 (&8(1*,1(&21752//(5 9$5,286 '5$:1%< 7+,6'5$:,1*&217$,16 35235,(7$5< ,1)250$7,21%(/21*,1* 72/(5$1&( 72:,1&2 81$87+25,=('86(,6 02'(/ 352+,%,7(' $//',0(61,216,1&+ 32 RI OPM-161/A 287387' )8(//(9(/6(1625 )/(;,%/(6(1625 6&5 $ % %&)$,/ (6723 (6723 67$57 67$57 *1' *1' %$77 %$77 )8(/ /(*(1' 3632:(56:,7&+ (66(0(5*(1&<67236:,7&+ )66)8(/6(/(&7,216:,7&+ 9$592/7$*($'-8670(175+(267$7 DSE7310 WIRING DIAGRAM WIRING DIAGRAMS THREE PHASE AC WIRE HIGH WYE THREE PHASE AC WIRING- DELTA THREE PHASE AC WIRE LOW WYE SINGLE PHASE 311 WINDING 33 OPM-161/A ENGINE GENERATOR SET LIMITED WARRANTY WINCO Inc. has been engineering and manufacturing high quality generators since 1927. WINCO Inc. warrants to the original owner that the purchased product is free from defects in materials and/or workmanship for the period of time outlined below. If the product should prove defective within the time period outlined below, it will be repaired, adjusted or replaced at the option of WINCO Inc., provided that the product, upon inspection by an authorized WINCO Inc. service center, has been found to have been properly installed, maintained and operated in accordance with WINCO Inc.’s Installation and Operating Manuals, engine manufacturer installation and operation guidelines, and National and local code. This limited warranty is not valid or enforceable unless: 1. All supporting product maintenance records are kept on file and made available upon request from WINCO Inc. 2. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to WINCO Inc. within 30 days of start-up. 3. The product is routinely exercised in accordance with operating instructions. This warranty does not apply to malfunctions caused by physical damage, misuse, improper installation, repair or service by unauthorized persons; or normal wear and tear. The warranty is not assignable. Prime WINCO Inc. Product Warranty Period: • Engine generator set: Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours (whichever occurs first). • Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours (whichever occurs first). Standby WINCO Inc. Product Warranty Period: • Engine generator set: Parts and Labor for two (2) years from the date of factory invoice or 2,000 hours (whichever occurs first). • Accessories (installed on the product or shipped loose): Parts and Labor for one (1) year from the date of factory invoice or 2,000 hours (whichever occurs first). The start of the warranty period can be adjusted to the date of unit start-up (limited up to 180 days from invoice date) provided that the following information is provided to WINCO Inc. at the time of start-up: 1. A copy of the WINCO Inc. Start-up Completion and Warranty Validation Checklist is properly and completely filled out and returned to WINCO Inc. within 30 days of start-up. 2. Some engines may require revalidation after long-term storage. The engine revalidation process if included in the manual must be followed. To obtain warranty service: Contact your nearest authorized WINCO Inc. service center. For assistance in locating your nearest authorized service center, contact WINCO Inc.’s Service Department. Warranty service may be performed by an authorized WINCO Inc. service center only. Service work performed by unauthorized persons will void all warranties. WINCO Inc. shall not be liable for any claim in an amount greater than the purchase price of the product. In no event shall WINCO Inc. be held liable for any special, indirect, consequential or liquidated damages. WINCO Inc. shall not be liable for any claim that requires replacement of engine, part, or component of the product that is no longer manufactured or available. Additionally, WINCO Inc. will not be liable for any engine replacement that may require an emissions tier-level change. THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED UNDER THE UNIFORM COMMERCIAL CODE, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE. The following items and/or circumstances are excluded from this limited warranty: • Engine starting batteries: The battery manufacturers’ warranty applies. Consult your local battery supplier for warranty service. • Fuel system and/or governing system adjustments performed during or after start-up. • Normal maintenance items: Consumable items such as belts, filters and hoses. • Damage caused by over-loading the generator and failure to adequately provide over-load protection. • LP/NG fuel adjustments or conversion from one fuel to another. • Any repeat or shop come-back repairs resulting from poor service work or improper diagnosis and testing. Replacement of parts as a trail-and-error method of diagnosis will not be considered for warranty. • Adjustments and tune–ups performed during start-up or thereafter. • Loose connections (electrical and mechanical) not found during start-up. • All fluid level related items including low coolant not found during start-up or checked during regular maintenance intervals. • Equipment modifications made without the written consent of WINCO Inc. will void all warranties. • Shipping damage of any type. All equipment is shipped F.O.B. factory and risk of loss transfers to the carrier once loaded for shipment. It is the responsibility of the receiving party to sign for the receipt of, and note any shipping damage to the equipment. Freight damage claim filing is the responsibility of the receiving party. In the rare event that damage occurs during shipment, WINCO Inc. will not warrant any damage to the unit resulting from packaging material. • Any special access fees, requirements or after hours scheduling to gain access to the equipment for warranty service purposes. • Rental generators used while warranty work is being performed. • Damages caused by acts of nature, such as lightning, wind, flood, wild fires, or earthquake. • Any damage due to situations beyond the control of the manufacturing and/or workmanship of the product. • Use of non-protected steel enclosure within 25 miles of the coast. • Damage caused by improper installation or failure to provide adequate ventilation. • Misapplication of the equipment such as usage outside the original design parameters as stated on the nameplate of the equipment. • Equipment purchased at the standby rating that is being used in a prime power application(s). • Diesel engine “Wet Stacking” due to lightly loaded diesel engines. • Travel time or service calls unless given written authorization by WINCO Inc. OPM-161/A 34LE CENTER, MN 56057 • 507-357-6821 WINCO INC. • 225 S. CORDOVA AVE • ">
Advertisement
Key features
- 28,000 Watts
- Standby & Prime Power
- Liquid-Cooled Engine
- Brushless AVR Generator
- EPA Compliant
- Skid Mounted
- Optional Accessories
Frequently asked questions
The fuel consumption rate at full load is 2.7 gallons per hour. The recommended oil type is Unleaded 87 or 89 Octane. Refer to the engine manual for additional fuel types and specifications.
The maximum ambient temperature is 120° Fahrenheit. Do not operate the generator in ambient temperatures exceeding this limit.
The unit requires a 12 Volt battery. Refer to the battery installation section for detailed specifications.