MT-1 Tracer Meter

Add to my manuals
13 Pages

advertisement

MT-1 Tracer Meter | Manualzz

MT-1 Tracer Meter

RENOGY MT-1 Tracer Meter for Duo Battery

Charge Controller

2775 E. Philadelphia St., Ontario CA 91761

1-800-330-8678

Table of Contents

Important Safety Instructions ........................................................................... 2

General Information ............................................................................................ 2

Identification of Display ..................................................................................... 3

Installation ........................................................................................................... 4

Operation ............................................................................................................. 4

Power On: Test Mode ....................................................................................... 4

Menu Display..................................................................................................... 4

User Parameter Setting ..................................................................................... 5

System Status Icons and Considerations ........................................................ 7

Test Mode ......................................................................................................... 7

Error Indicator.................................................................................................... 7

Telecommunication Port .................................................................................... 7

Battery Level Flashing ....................................................................................... 8

Battery capacity AH ........................................................................................... 8

Troubleshooting .................................................................................................. 8

Technical Specifications .................................................................................... 8

Electrical Parameters ........................................................................................ 9

Mechanical Parameters ..................................................................................... 9

Temperature Parameters .................................................................................. 9

CAD Dimensions ............................................................................................... 9

Limited Warranty for Accessories ..................... Error! Bookmark not defined.

1

Important Safety Instructions

Please save these instructions.

This manual contains important safety, installation, and operating instructions for the charge controller. The following symbols are used throughout the manual to indicate potentially dangerous conditions or important safety information.

WARNING : Indicates a potentially dangerous condition. Use extreme caution when performing this task.

CAUTION: Indicates a critical procedure for safe and proper operation of the controller

NOTE: Indicates a procedure or function that is important to the safe and proper operation of the controller.

General Safety Information

Read all instructions, cautions, and notes in the manual before starting the installation.

There are no serviceable parts inside the MT-1. Do not disassemble or attempt to repair the meter electronics

Do not allow water to enter the MT-1.

General Information

The Renogy MT-1 Tracer meter is the remote digital display used for the 10Amp or

20Amp Duo Battery Charge Controllers. It is a self-diagnostics meter ideal for monitoring and displaying the current solar system status information and any error indications the system might be experiencing. The information is displayed on a backlit LCD display and is easily navigated using the large buttons on the meter. The MT-1 Tracer meter could also be flush mounted on a wall or flat surface using the mounting frame provided. The

MT-1 Tracer is supplied with a 10 meter long cable and is connected using the RJ45 port.

Key Features

Displays both solar voltage and battery voltage

Displays charging current and load current

Displays Amp-Hour and Watt-Hour accumulation

2 different brightness levels for the LCD display

Included Components

Wall Mounting Frame

10 meter cable

Components NOT included

Screws  ø 4mm (0.16in)

2

3

2

Identification of Display

1

10

4

5

6 7 8 9

1. Solar Icon

2. Battery Icon(s) —icon is present if the battery is connected otherwise it will remain flashing. It will demonstrate the battery level in which each bar represents 20% of the battery capacity.

3. Remote Temperature Sensor Icon (optional) —if the charge controller has the

Remote Temperature Sensor connected (separate purchase required), the meter will display this icon.

4. Local Temperature Sensor Icon —indicates the current temperature of the room.

5. Setting Icon —icon is present when the user is modifying parameters of the controller such as brightness, clock, temperature units, or screen cycling.

6. Error Indicator —indicates improper connection, tracer error, or short circuiting of the battery or solar panels.

7. Data Repeat Icon —the meter will automatically cycle through the different screens.

8. Backlight on Icon

—indicates backlight is on.

9. Self-Test Indicator —when the tracer is powered on, it will “TEST” through all screens and make sure everything is running appropriately.

10. Data Units

3

Installation

CAUTION: Before installing the MT-1 Tracer, apply power and make sure the meter is working properly. Resolve any issues before installing the meter and the meter cable.

The MT-1 can be mounted in two ways: Frame Mount or in a Wall Mount. A plastic mounting frame has been included for the purpose of Frame Mounting. If Wall Mounting then the MT-1 faceplate sits flush with the mounting surface and the body of the meter would be able to rest comfortably in a hole cut-out on the mounting surface.

NOTE: The screws are NOT included for installation purposes.

Operation

The following keys are used to cycle through the screens or adjust the parameters on the tracer :( K1) NEXT, (K2) (), (K3) (), (K4) SET

NOTE: Both batteries must be connected to the charge controller, otherwise there

will be a default error.

Power On: Test Mode

Once powered on, the meter will have both Charge and Error LED’s on as well as display all the icons for approximately 5 seconds. Once completed, it will begin TEST mode by which it will cycle through each of the following indicators:

1. Remote Temperature Sensor reading (optional)

2. Battery 1 Voltage

3. Solar Panel Reading

7. Units

8. Setting Icon

9. Error Indicator

10. Data Repeat Icon

4. Battery 2 Voltage

5. Local Temperature reading

6. Time

11. Backlit indicator

12. Min, max, percentage

NOTE: Test mode can be manually activated by pressing NEXT + ()

Menu Display

After TEST mode, the user can use the NEXT key to cycle through four menus: PV Solar

Information, Battery 1 Information, Battery 2 Information, and Temperature/ Time Information.

The user can also use the (K2) (), (K3) () keys to cycle within the four menus and display more information .

4

Data Screens

PV Solar Battery 1 and Battery 2 Temperature / Time

1. Solar Panel Volts (V)

2. Solar Panel Amps (A)

3. Max Solar Panel Amps (A/

MAX

)

4. Generated Amp-Hours (Ah)

5. PWN Charge Frequency (Hz)

6. Charge Priority Percentage (R)

1. Battery Voltage (V)

2. Max Battery Voltage (V/

MAX

)

3. Min Battery Voltage (V/

MIN

)

4. Battery Amp-Hours (Ah)

1. Remote Temperature

Reading (optional)

2. Time

3. Local Temperature Reading

**The following data represents the 4 menus and the corresponding sub displays.

User Parameter Setting

By pressing the SET button, the user is able to modify some parameters of the meter. They include: Temperature Units, Backlight Timer, Backlight Brightness, Data Repeat Option, and clock. The user uses the (K2) () and (K3) () to adjust the parameter, and then press (K4)

SET again to save the setting.

The icon will be displayed when the user is in the SET function. It will disappear once the user is in the reading menu.

Function Display

Temperature dEg

Description

Changes Temperature Units

(C°) to (F°)

Backlight B: Sets a backlight timer after last button push

On: Always on

B:30 – 30 seconds B:20 – 20 seconds

B:10 – 10 seconds B:05 – 5 seconds

Off: - Always off

Brightness

Data Repeat

Time

Full: Full: high brightness Half: low brightness

Auto Auto: Each Menu and submenu repeats every 3 seconds

Off: No data will repeat unless the user presses the arrow keys.

00:00 H: M Adjust the hours and minutes of the clock.

System Status Icons and Considerations

Test Mode

At any time the user can press the NEXT + () to activate test mode. Test mode checks and displays the related data automatically. The user might experience the following display when undergoing test mode:

“NO”—there is no connection. Connect a battery if applicable. In the default reading screen the battery icon will be flashing.

OPEN”—indicates that there is no battery connection, or the battery is voltage. Check manufacturer specifications and ensure system is appropriate. over

Error Indicator

The red LED on the tracer is on or the “ ”symbol is visible in the digital display. Possible reasons for the Error Indicator include:

1. One battery could be disconnected, over voltage, or open circuit. Check connections. Disconnect and reconnect.

2. The remote temperature sensor probe is malfunctioning. Check the sensor probe.

Disconnect and reconnect.

3. The system is experiencing overcharging current. Check connections, disconnect and reconnect

4. Solar PV is short circuited. Check connections, disconnect and reconnect.

NOTE: Both batteries must be connected to the charge controller, otherwise there will be

a default error.

Telecommunication Port

When the meter running on individual power or the communication is cut off, the MT-1 will display graphical symbols abnormally. Press any key to stop the display and resume normal activity. IF problem persists, disconnect the port and connect it again. Normal behavior is when the meter updates every 20 seconds.

NOTE: Errors could occur in the telecommunication port if the connection is not properly

secured. Also, too long of a cable may cause some inconsistencies.

Battery Level Flashing

Each strip equals to 20% of battery capacity. The bar that is flashing indicates that the battery is within the next increment of 20% of the battery capacity. For example: when the first bar is flashing, the battery is at 1-19% of capacity. Similarly, when the second bar of the battery is flashing, then the capacity is at 21-39%.

NOTE: The meter measures battery capacity by the voltage it is experiencing. When batteries are charging, they will not necessarily match the accurate battery capacity.

Battery capacity AH

AH is the accumulation of charging, each one minute will count. The data is not accurate while the charge current is too small. The min. is 1AH, means 1 amps charging for 1 hour, Ah comes to show.

Troubleshooting

MT-1 has no display

Verify that the duo battery charge controller is powered on and that it is connected to the

MT-1. The MT-1 is powered by the duo battery charge controller.

LCD display is dim

Make sure that the MT-1 is not in half-brightness mode.

Check the system battery voltage. The MT-1 needs a minimum of 8 V to operate.

Verify that the temperature is within range of the LCD operating parameters.

MT-1 turns on, but shows no data

MT-1 is potentially damaged or the cable is damaged. Replace the cable by contacting the manufacturer.

MT-1 display does not match product manual

Our products undergo manual revisions from time to time. Please check our website at

Renogy-store.com > downloads for latest documentation.

Buttons do not work

Disconnect the MT-1 and clean the faceplate to remove any potential buildup of residue

Reconnect MT-1

Technical Specifications

Electrical Parameters

Rated Voltage 12V

Minimum Voltage Suggested 8V

Strong backlight on

Low Backlight on

< 23mA

< 20mA

Backlight and LED indicator off < 17mA

Mechanical Parameters

Communication Cable

Cable Length

RJ45 (8 pin)

10 meters

Faceplate Dimensions

Wall Frame Dimensions

95 x 95mm (3.74 x 3.74in)

110 x 110mm (4.33 x 4.33in)

Temperature Parameters

Operation Temperature -40 °F to 140°F

LCD Operation Temperature -14 °F to 104°F

Humidity 0-100%

CAD Dimensions

NOTE: Dimensions are in millimeters (inches)

Updated: July 30, 2015

www.Renogy.com

Limited Warranty for Accessories

Thank you for your interest in the products and services of RNG Group Inc. By acquiring the products of

RNG Group Inc., you have purchased quality. As a sign of confidence in our quality, we are pleased to grant you with the following warranties for our photovoltaic products.

1. Limited Warranty

The products manufactured by RNG Group Inc. (the “Warrantor”) are warranted to be free from defects in workmanship and materials under normal use and service. The warranty is in effect from the date of purchase by the user (the “Purchaser”). This limited warranty covers substantial defects in material or workmanship and performance.

If any RNG Group Inc. product(s) fail to follow this Limited Warranty and any and all power loss is determined by the Warrantor’s technical support team then the Warrantor will either repair or replace the defective product(s) with a new or refurbished product(s). All replacements will be compatible with the original product(s) with an equal or even greater power rating (in some cases). If for any reason RNG

Group Inc. is unable to repair or replace the defective product(s) then a refund can occur.

*Please note that all outsourced product(s) will not be covered by RNG Group Inc.’s limited material and workmanship warranty. Instead, outsourced products will be covered under the original manufacturer’s warranty, if applicable. Including but not limited to Samlex America, Enphase Energy, MidNite Solar Inc.,

VMAX USA, UPG (Universal Power Group), etc.

Material and Workmanship Warranty period for the following products after August 1 st , 2015:

INVT-500-12V; INVT-1000-12V; INVT-1500-12V; INVT-2000-12V

3 year material and workmanship warranty

AK-10FT-10; AK-10FT-12; AK-20FT-10; AK-20FT-12; AK-30FT-10; AK-30FT-12;

AK-40FT-10; AK-40FT-12; AK-9IN-12; BATTERYCB-12IN-4; BATTERYCB-14IN-

4; BATTERYCB-16IN-4; EXTCB-1.5FT-12; EXTCB-5FT-10; EXTCB-5FT-12;

EXTCB-10FT-10; EXTCB-10FT-12; EXTCB-15FT-10; EXTCB-15FT-12; EXTCB-

20FT-10; EXTCB-20FT-12; INVTCB-5FT-4; TRAYCB-8FT-8; TRAYCB-8FT-10;

TRAYCB-8FT-12; TRAYCB-16FT-8; TRAYCB-16FT-10; TRAYCB-16FT-12;

CNCT-FUSE10; CNCT-FUSE15; CNCT-FUSE20; CNCT-FUSE30; CNCT-MC4;

CNCT-MC4Y; TRCRMTR-MT-5; TRCRMTR-MT-150; TRCRMTR-MT-50;

TRCRMTR-MT-5; TRCRMTR-MT-1; CTRL-MPPT20; CTRL-MPPT40; CTRL-

PWM10DB; CTRL-PWM10; CTRL-PWM20DB; CTRL-PWM30; CTRL-PWM30-

LCD; CTRL-PWM5; CTRL-PWM10-LCD-VS; CTRL-PWM20-LCD-VS; CTRL-

PWM30-LCD-VS; CTRL-ADV30-LCD; CTRL-WND30; MTS-ZB; MTS-SP100;

MTS-TM100; MTS-EC35; MTS-EC40; MTS-EC50; MTS-LF; MTS-MC35; MTS-

MC40; MTS-MC50; MTS-RS; MTS-RL5FT; MTS-QMSC; MTS-BDRL10FT;

TRCRMTR-MT-150; TOOL-MC4; CTRL-VS-TS; CMP-SF25000; LED-MR16; LED-

BULB; LED-BULBX4; LED-STRIP; CMP-B-EGO14.1; CMP-EGO10000; CMP-

EGOS2800; CMP-EFL14; CMP-EBOT-S; CMP-EBOX-2.1; CMP-EGOMN2600

1 year material and workmanship warranty

2. General Conditions for Warranty Claims

For Workmanship and Material Warranty: If the Purchaser experiences any defects in materials and workmanship under normal application, such as defects and/or failures due to manufacturing or due to materials, it is their responsibility to contact the Warrantor’s technical support team. The technicians will offer steps and procedures to test the product(s), repair the product(s) or require the Purchaser to ship the product(s) to the technical support team if needed. Based on the outcome, the warranty service will then be in effect.

This warranty extends only to the original Purchaser. If gifted or resold the customer must go through the original Purchaser in order to claim warranty. Original order information is needed to claim warranty. If original order was shipped within the US, the Purchaser will be responsible for additional shipping costs out of the US. The Customer’s sole and exclusive remedy and the entire liability of the Warrantor, its suppliers and affiliates for breach of the warranty is, either to replace the product(s) or component parts of the product(s) and in some cases refund the product(s) cost. This warranty does not cover labor.

Products that have been serviced or replaced under their warranty period do not receive extended warranties. Instead, the serviced/replaced product(s) will abide to the original warranty period issued when first purchased. No employee, agent, dealer or any other person is authorized to give any warranties on behalf of the Warrantor, not expressly set forth in this limited warranty.

3. Exclusions and Limitations

The warranty does not cover failures result from incorrect handling, product modifications, installation, conversion or additions, supplements, operation, natural elements (weather), excessive or deficient energy supply, chemicals, the effect of solid bodies or deliberate damage. If the Warrantor determines that the problem with the product(s) is not due to a manufacturing defect in the Warrantor’s workmanship or materials, or otherwise does not qualify for warranty repair, then the Purchaser will be responsible for all costs incurred by the Warrantor necessary to repair, replace and transport the product(s).

The warranty shall be asserted with the Warrantor in writing enclosing a copy of the invoice and a description of the defect/loss of performance within the warranty period. The Warrantor shall accept no returns of product(s) without the previous written request for this. Within five (5) business days of the date of notification, the Warrantor will provide the Purchaser with an RMA number and the location to which the Purchaser must return the defective module(s). Any product(s) returned for valid warranty service shall be shipped at the expense and risk of the Warrantor. The Purchaser must return the product(s) (or, if authorized by the Warrantor, the defective component parts), within fifteen (15) days after issuance of the RMA number. The Warrantor will be under no obligation to accept any returned product(s) that does not have a valid RMA number. All parts that the Warrantor replaces shall become the Warrantor’s property on the date the Warrantor ships the repaired product(s) or part back to the Purchaser. The

Warrantor will use all reasonable efforts within thirty (30) days of receipt of the defective product(s) to repair or replace such product(s). If a warranty claim is invalid for any reason, the Purchaser will be charged at the Warrantor’s then-current rates for services performed and will be charged for all necessary repairs and expenses incurred by the Warrantor. If the Warrantor determines that a warranty claim is valid, it will ship the repaired or replaced product(s) to the Purchaser at the Warrantor’s cost.

RNG GROUP INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED,

INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY

OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE.

LIMITATION OF LIABILITY

UNDER NO CIRCUMSTANCES WILL RNG GROUP INC. OR ITS AFFILIATES OR SUPPLIERS BE

LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE, INTERRUPTION OF BUSINESS, LOST

PROFITS, LOST DATA, OR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES

OF ANY KIND REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, TORT

(INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, EVEN IF RENOGY OR ITS

AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you. Neither RNG Group Inc. nor its affiliates or suppliers will be held liable or responsible for any damage or loss to any items or products connected to, powered by or otherwise attached to the Product. The total cumulative liability to the Purchaser, from all causes of action and all theories of liability, will be limited to and will not exceed the purchase price of the Product paid by the

Purchaser. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.

RNG Group Inc.

2775 E. Philadelphia St.

Ontario, CA 91761

Phone: 800-300-8678

Fax: 888-543-1164

Email:

General Inquiries: [email protected]

Sales Inquiries: [email protected]

Technical Support Inquiries: [email protected]

Customer Service Inquiries:[email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement