Eurolux D110 LED Panel Downlight 3W Round 4000K Owner's Manual
Reklama
Reklama
ILLUSTRATIONS
D110
Round Straight Downlight
D112 D113
ENVIRONMENTAL PROTECTION
Waste electrical & Electronic equipment regulations requires that any of our products showing this marking must not be disposed of with other household or commercial waste. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate any such products from other waste types and recycle it responsibly at your local facilities.
D114 D115 D116
D110:
Including 1 x 3W Integrated LED,
D112:
Including 1 x 6W Integrated LED
D113
: Including 1 x 9W Integrated LED,
D114:
Including 1 x 12W Integrated LED
D115:
Including 1 x 15W Integrated LED,
D116:
Including 1 x 18W Integrated LED
PRODUCT CODE
D110 / D112 / D113 / D114 / D115 / D116
Cape Town - 9 Racecourse Road, Milnerton, 7441
Johannesburg - 10 Milkyway Avenue, Linbro Business Park, Sandton, 2065 www.eurolux.co.za
Please read instructions before commencing installation and retain for future reference.
SPECIFICATIONS
• Fitting: White Die Cast Aluminium with a Opal Polycarbonate Lens
• Lamp type: D110 - Including: 1 x 3W Intergrated LED
D112 - Including: 1 x 6W Intergrated LED
D113 - Including: 1 x 9W Intergrated LED
D114 - Including: 1 x 12W Intergrated LED
D115 - Including: 1 x 15W Intergrated LED
D118 - Including: 1 x 18W Intergrated LED
• Class: Class 2. Does not require earth connection.
• IP Rating: IP44. Protected against solid foreign objects of 1.0mm Ø and greater.
Protected against splashing water.
• Commercial / domestic use
• Not suitable for outdoor use
• Maximum Ambient temperature range: 20ºC - 40ºC
• Dimensions: D110 - D) 22mm x (Ø) 90mm
• Cut-out:
D112 - D) 22mm x (Ø) 120mm
D113 - D) 22mm x (Ø) 130mm
D114 - D) 22mm x (Ø) 1700mm
D115 - D) 22mm x (Ø) 195mm
D118 - D) 22mm x (Ø) 225mm
D110 - 70mm
D112 - 100mm
D113 - 130mm
D114 - 150mm
D115 - 175mm
D118 - 200mm
IMPORTANT SAFEGUARDS
attachments:
If the external flexible cable or cord of this luminaire is damaged, it should be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.To ensure that you get maximum longevity and maximum use out of your luminaire, please observe the following safety instructions.
Electrical products can cause death, injury, or damage to property. Installation of the luminaire must be carried out by a qualified electrician, in accordance with SANS 10142. On completion of installation, ensure that the Certificate of Compliance is updated.
• Before connecting the luminaire, ensure that voltage indicated on the rating label
corresponds with the mains voltage in your home.
• When changing the lamp, ensure that the power is turned off.
• Ensure that the correct lamp type and wattage is fitted.
• This luminaire is checked in full for conformity to the quality standards and safety requirements.
• The manufacturer / supplier is not responsible for any damage of properties and
persons, caused by the incorrect use or installation of the luminaire.
• Should you be unsure of how to install this luminaire correctly, please consult a
professional electrician or your supplier for assistance.
• Ensure all items/ components, threads and screws are tightly secured.
IMPORTANT:
• Tampering with this luminaire, i.e.using silicon sealers or incorrect cabling, will
invalidate your warranty.
• When the protection glass is damaged, it should be replaced immediately.
• Please check whether the connection of the power cord is safe and reliable before installation.
• If your mains wiring differs in any way from diagram luminaire, consult a qualified electrician.
• Always ensure that the mains supply voltage is correct.
• Always replace the lamp with one of an identical rating and wattage.
• Choking hazard: May contain small parts. Keep away from children.
• Do not insert your fingers or any part of your body into the electrical contact and
sockets of this product whilst it is connected to the electrical supply.
• Item may vary slightly from the picture on the carton.
INSTALLATION
Before installation always ensure the power supply is turned off.
1 Cut a hole in the ceiling as per ‘‘cut out”.make sure there are no beams or structures were you will be cutting the holes.
2 Connect to electrical supply.
3 Hold both clips on either side of downlight upwards and insert downlight into ceiling hole ensuring the mains lead is not trapped.
4 Push fitting upwards to snap firmly into position,flush with ceiling.
5 Insert the lamp by location the pin connection holes within the lamp holder, gently pushing the lamp into holder and sliding into place.
6 Reconnect power.
Note: Always allow the lamp to cool sufficiently before changing.
Note: To avoid heat transfer from download, allow a minimum gap of about 200mm in height from downlight to ceiling / any materials above the downlight and 200mm all around side of the downlight.
7 Failure to do so could result in fire.
CLEANING
• Before cleaning always ensure the power supply is turned off.
• Do not immerse the luminaire in water.
• No abrasive products, solvents, detergent may be used to clean this luminaire.
• Ensure that the fitting does not come in contact with corrosive chemicals, etc.
• Use a soft cloth to clean.
Stiahnuť
Reklama