Echo360 ALP Admin User Guide
Administrator
User Guide
Active Learning Platform
December 2015
Table of Contents
Getting Administrators Started ................................................................................................... 1
Understanding the Admin HOME Page .................................................................................... 2
Defining the Active Learning Platform Hierarchy .................................................................... 3
Creating Organizations and Departments ............................................................................... 4
Verify or edit institution settings ............................................................................................... 4
Create or edit an organization ............................................................................................... 4
Create a department .............................................................................................................. 5
Applying Video Branding for the Institution .............................................................................. 6
Watermarking ............................................................................................................................ 6
Intro Clip ..................................................................................................................................... 7
Outro Clip ................................................................................................................................... 7
Enabling/Disabling Features for the Institution ......................................................................... 9
Disabling Questions (Q&A) ...................................................................................................... 9
Disabling Course Creation (for external LMS users) ........................................................... 10
Disabling Automatic Instructor Creation (for external LMS users) .................................... 10
Adding Campuses and Buildings ............................................................................................. 12
Creating a campus and building(s) ..................................................................................... 12
Manually Adding Rooms ........................................................................................................... 14
Create Rooms Using Bulk Import .............................................................................................. 15
Managing Users .......................................................................................................................... 17
Manually Adding Users .............................................................................................................. 18
Bulk Import Users ......................................................................................................................... 19
Editing Users ................................................................................................................................. 22
Editing multiple users (bulk-edits) .......................................................................................... 23
Adding and Editing User Enrollments ....................................................................................... 25
Revoking sections or changing section role ....................................................................... 26
Creating Terms ............................................................................................................................ 28
Creating Courses ........................................................................................................................ 29
Creating Sections ....................................................................................................................... 30
Creating Courses and Sections via CSV Import ..................................................................... 32
Scheduling Sections ................................................................................................................... 35
Scheduling Section Captures via CSV Import ........................................................................ 39
Formatting Dates for CSV Imports ............................................................................................ 45
i
Table of Contents
Configuration Requirements for Live Streaming .................................................................... 47
Live streaming is only available for section captures ........................................................ 47
Why? ..................................................................................................................................... 47
Live streaming requires an SCHD or Echo360 PRO appliance ......................................... 47
Check and configure outbound port communications ................................................... 47
Working with Devices ................................................................................................................. 49
Log On and Monitor Device ................................................................................................. 49
Filtering Rooms by Device Status .......................................................................................... 49
Configuring Capture Devices ................................................................................................... 51
Setting up SCHD and PRO devices ...................................................................................... 51
Setting up Classroom Capture devices ............................................................................... 52
Common Settings - Device Defaults ........................................................................................ 54
Assigning a Device to a Room ................................................................................................. 56
Editing Individual Appliance Configurations .......................................................................... 57
Viewing Device and Room Status ........................................................................................... 59
Understanding Device Status ................................................................................................... 60
Echo360 SafeCapture HD Specifications ................................................................................ 62
General specifications ........................................................................................................... 62
Agency certifications ............................................................................................................. 63
Appliance display resolutions ............................................................................................... 63
Deployment options ............................................................................................................... 63
Display input ............................................................................................................................ 63
Video input .............................................................................................................................. 64
Audio input .............................................................................................................................. 64
Unpack and Connect the SafeCapture HD........................................................................... 65
What's in the box ..................................................................................................................... 65
Installing/Connecting the SCHD ........................................................................................... 66
Safety Instructions and Regulations for the SafeCapture HD .............................................. 68
Safety Symbols ........................................................................................................................ 68
Important Safety Instructions ................................................................................................. 68
Rack Mount Installation.......................................................................................................... 70
Regulatory Compliance Information ................................................................................... 70
Radio and Television Interference ........................................................................................ 71
Disposal and Recycling .......................................................................................................... 72
Audio Bare Wire Block Diagram for the SafeCapture HD .................................................... 73
ii
Table of Contents
SCHD Input and Device Settings .............................................................................................. 74
Understanding the LEDs on the SafeCapture HD .................................................................. 76
Descriptions of the LEDs ......................................................................................................... 77
Troubleshooting the SafeCapture HD Power Supply............................................................. 79
Remove and Inspect the Fuse Block.................................................................................... 79
Check for Improper Assembly .............................................................................................. 81
Fuse Not Properly Placed in Fuse Slot ............................................................................... 81
Missing Metal Clip................................................................................................................ 82
Performing a Factory Reset on the SafeCapture HD ............................................................ 83
Echo360 PRO Device Specifications........................................................................................ 85
Deployment Options .............................................................................................................. 85
Display ...................................................................................................................................... 85
Appliance Display Resolutions .......................................................................................... 86
Video ........................................................................................................................................ 86
Audio ........................................................................................................................................ 86
NOTES about HDMI Audio .................................................................................................. 86
Package Options .................................................................................................................... 87
Signal Processing and Encoding .......................................................................................... 87
General .................................................................................................................................... 87
Agency Certifications ............................................................................................................ 87
Installing the Mounting Brackets on the Echo360 PRO ......................................................... 88
Rack mount configuration..................................................................................................... 88
Bracket installation for rack mounting ................................................................................. 88
Install the Echo360 PRO ............................................................................................................. 91
Installation ................................................................................................................................ 91
Configure the Echo360 PRO ..................................................................................................... 93
Configure and download default PRO device settings.................................................... 93
Enable/Disable Administration menu access ................................................................. 93
Set the One-Touch recording profile ................................................................................ 93
Apply the configuration file to the PRO device ................................................................. 94
Register the PRO device and check the installation and inputs ..................................... 95
Next Steps ................................................................................................................................ 96
Configuring Echo360 PRO Input and Device Settings........................................................... 97
Audio Bare Wire Block Diagram for Echo360 PRO ............................................................... 100
About the Front Panel of the Echo360 PRO.......................................................................... 101
iii
Table of Contents
The Buttons ............................................................................................................................. 101
The Status Screen .................................................................................................................. 103
Device Messages .................................................................................................................. 106
Menus and Options for the Echo360 PRO............................................................................. 108
Home Menu ........................................................................................................................... 108
Recording Menu ................................................................................................................... 108
Inputs Menu ........................................................................................................................... 111
Network Menu ....................................................................................................................... 111
Status Menu ........................................................................................................................... 112
Administration Menu ............................................................................................................ 113
Manage Network.................................................................................................................. 115
Echo360 PRO FAQs and How To's .......................................................................................... 116
How-to... ................................................................................................................................. 116
Configure Channel inputs ................................................................................................ 116
Start an ad hoc recording ............................................................................................... 117
Ping the device ................................................................................................................. 117
Save a Diagnostics Report ............................................................................................... 118
Save a capture to USB-storage ....................................................................................... 118
Recover captures from the SSD ...................................................................................... 119
FAQs ........................................................................................................................................ 120
Which USB port should I use? ........................................................................................... 120
What is the One-Touch Profile? ....................................................................................... 120
What is the Custom Profile? ............................................................................................. 120
What is 'Recovery Mode' and how should I use it? ...................................................... 121
How can I monitor audio? ............................................................................................... 121
Safety Instructions and Regulations for the Echo360 PRO .................................................. 122
Safety Symbols ...................................................................................................................... 122
Important Safety Instructions ............................................................................................... 122
Rack Mount Installation........................................................................................................ 124
Regulatory Compliance Information ................................................................................. 124
Radio and Television Interference ...................................................................................... 125
Disposal and Recycling........................................................................................................ 126
Working with Captures............................................................................................................. 127
Navigating the captures page ........................................................................................... 127
Review capture playback ................................................................................................... 128
iv
Table of Contents
Viewing Detailed Capture Information ................................................................................. 129
Editing, Reprocessing, and Deleting Captures .................................................................... 132
Captures page options ........................................................................................................ 132
Reprocess a capture ............................................................................................................ 133
Edit a capture or video ........................................................................................................ 133
Edit capture media details .................................................................................................. 134
Delete a capture .................................................................................................................. 135
Editing Videos............................................................................................................................ 137
Using the video editing tools ............................................................................................... 138
Review/Playback the video ............................................................................................ 138
Cutting segments from the video ................................................................................... 139
Add Captures ........................................................................................................................... 141
Uploading Captures................................................................................................................. 144
Changing ownership ............................................................................................................ 144
Publishing and Sharing Captures ........................................................................................... 146
Publishing a capture to a class ........................................................................................... 146
Sharing a capture with another user ................................................................................. 147
Getting a Video's Public Link (for Admins) ............................................................................ 149
Controlling Captures Through Device Web Interface ........................................................ 150
Log in to the SCHD or PRO device web interface ........................................................... 150
Controlling an active capture ............................................................................................ 151
Monitoring captures ............................................................................................................. 152
Ad Hoc Captures...................................................................................................................... 153
Log in to the SCHD or PRO device web interface ........................................................... 153
Create ad hoc captures ..................................................................................................... 154
Recovering Ad Hoc Captures ................................................................................................ 156
Device Monitor Overview - Administrators ........................................................................... 158
Installing the Device Monitor Software .................................................................................. 159
Launch the Device Monitor .................................................................................................... 160
Device Configuration Defaults ............................................................................................... 161
Device Monitor Adhoc Capture and Settings ..................................................................... 163
Device Monitor Light Defaults................................................................................................. 165
Using the Light to Control the Capture ................................................................................. 168
Locking the Configuration ...................................................................................................... 170
Device Monitor Admin Override ............................................................................................ 171
v
Table of Contents
Applying admin override settings ....................................................................................... 171
Example adminOverride.xml file ......................................................................................... 172
vi
Administrator User Guide
Getting Administrators Started
The following is a typical workflow for an administrator just getting started with the
Active Learning Platform:
1. Create an organization and departments.
2. Add a campus and building.
3. Install and configure capture devices.
4. Add rooms.
5. Add users.
6. Create terms, courses, and sections for the classes being offered.
7. Schedule sections for capture, so that classroom lectures can be recorded.
8. As necessary, you can also add and then publish captures outside of scheduled
classes.
Depending on your other requirements, you will also want to review the topics located
in the Advanced Configuration section of the help, such as Configuring Authentication
or Configuring the Active Learning Platform with your LMS.
1
Administrator User Guide
Understanding the Admin HOME Page
The Administrator's HOME page provides overview information about the captures
slated to occur today. The captures listed are those whose start time falls between
12am and 11:59pm on the date shown at the top of the list (today by default, but can
be changed).
Use the arrows next to the date above the captures list to change what captures are
shown.
Use the filters on the left to change the captures shown based on capture status.
More detailed information on system captures, additional functional and
search/filtering options are available on the CAPTURES page.
2
Administrator User Guide
Defining the Active Learning Platform Hierarchy
The Active Learning Platform organizational hierarchy is as follows: Institution >
Organization > Department.
An institution is the top-most level of the Active Learning Platform hierarchy. Typically
the institution identifies the university. This is set up for you when your Active Learning
Platform account is established.
Within each institution there can be one or more organizations. Typically the
organization identifies a school within the university, such as a medical school or other
entity. Each organization can then have one or more departments, such as the Nursing
department or the English department.
Use of organizations and departments is optional. If your initial deployment is small, and
your institution does not need that level of compartmentalization, you do not need to
create them right away. As your deployment grows, you can add them and categorize
your courses accordingly.
The diagram below shows the relationship between a full Active Learning Platform
hierarchy and the corresponding course and section being offered from the Nursing
Department: NURS141-001
3
Administrator User Guide
Creating Organizations and Departments
Use of organizations and departments is optional. If your initial deployment is small, and
your institution does not need that level of compartmentalization, you do not need to
create them right away.
As your deployment grows, you can add them and categorize your courses
accordingly.
See also Defining the Active Learning Platform Hierarchy for information on how the
organizational structure is used in the system.
Verify or edit institution settings
When your Administrator account is created, you are assigned to one or more
institutions. You can change the name of an institution if necessary but it cannot be
deleted.
To access institution account settings
1. Select the settings icon in the upper-right corner of the screen.
2. From the list, select Account Settings.
3. From the left panel of the Account Settings screen, select Institution.
4. Review and if necessary, edit the Name of the institution.
5. Click SAVE.
Create or edit an organization
Organizations allow you to establish sub-divisions of the Institution, such as a medical
school or school of journalism.
BEFORE creating the organization, be sure you are logged into the correct institution.
To create an organization
1. Click the settings icon in the upper-right corner of the screen.
2. From the list, select Account Settings.
3. From the left panel of the Account Settings screen, select Institution.
4. Scroll down to the Organizations section of the screen.
5. Enter the organization name in the Name box and click ADD.
NOTES:
-- You may need to scroll to the bottom of the Organization list to add subsequent
organizations.
-- Use EDIT to modify the organization name if necessary.
4
Administrator User Guide
Create a department
Most Active Learning Platform configurations have a single institution containing a
single or perhaps only a few organizations. However it is likely you will have several
departments. Furthermore, your course offerings are segregated specifically by
department.
Departments represent the branch of a school or program responsible for providing the
course.
Creating departments is done on the Courses page.
To create a department
1. From the main menu, click Courses.
2. At the upper-right section of the Courses page, click Add Department.
3. From the list, select the Organization for the department.
4. Enter a Name for the department.
5. Click SAVE.
5
Administrator User Guide
Applying Video Branding for the Institution
Active Learning Platform allows you to apply institutional branding to all videos
processed and served through ALP. This branding can be applied via watermarking,
and by adding intro and/or outro clips to the videos.
Configured branding is applied to all videos across the institution, including captures as
well as user-uploaded video files. Furthermore, disabling the branding feature later will
not remove it from already-processed video files. This also applies to changing the
watermark or intro/outro clips used. Once a video has been processed with the
branding item, it is retained.
Watermarking
Watermarking is the process of overlaying a semi-transparent image on a video file, so
that viewers recognize the institutional owner of the content.
Watermarking in ALP applies the image to the bottom-right corner of the video.
To apply watermarking to videos
1. Log in as an administrator.
2. Select Account Settings from the Settings menu.
3. On the left side of the Settings page, click Video branding.
4. At the top of the Video branding page, enable the Watermark slider.
5. Click Select File to upload the file to use.
6. Use the Filepicker.io window to locate and select the file.
Once uploaded, the image appears in the preview box.
7. Click SAVE.
6
Administrator User Guide
All videos processed from this point forward will contain the uploaded image, at 20%
transparency, in the bottom right corner of the video.
Intro Clip
Adding an Intro Clip to your video branding configuration adds the uploaded clip to
the opening of all videos processed for this institution.
Keep clips short! There is no constraint on the length of the video clip used for the intro,
but users might get annoyed with (and then Tweet about) having to sit through
excessive intro viewing time.
To apply an intro clip to videos
1. Log in as an administrator.
2. Select Account Settings from the Settings menu.
3. On the left side of the Settings page, click Video branding.
4. In the middle of the Video branding page, enable the Intro clip slider.
5. Click Select File to upload the video clip file to use.
6. Use the Filepicker.io window to locate and select the file.
Once uploaded, the image appears in the preview box.
7. Click SAVE.
All videos processed from this point forward will begin with the video clip you provided.
Outro Clip
Adding an Outro Clip to your video branding configuration adds the uploaded clip to
the end of all videos processed for this institution.
Keep clips short! There is no constraint on the length of the video clip used for the outro,
but users are not likely to sit through very much after the main part of a video has
completed.
7
Administrator User Guide
To apply an outro clip to videos
1. Log in as an administrator.
2. Select Account Settings from the Settings menu.
3. On the left side of the Settings page, click Video branding.
4. At the bottom of the Video branding page, enable the Outro clip slider.
5. Click Select File to upload the video clip file to use.
6. Use the Filepicker.io window to locate and select the file.
Once uploaded, the image appears in the preview box.
7. Click SAVE.
All videos processed from this point forward will end with the video clip you provided.
8
Administrator User Guide
Enabling/Disabling Features for the Institution
Some Echo360 Active Learning Platform (ALP) features can be turned on or off at the
Institution level. When disabled, the features that users would normally see and which
are described here in the Online Help, are not available.
Disabling Questions (Q&A)
Some institutions do not want to allow the student/instructor Q&A or student discussion
capability for classes. The Q&A capability is enabled for all institutions by default but
can be disabled by an Administrator at the institution level.
To disable Questions (Q&A) across the institution
1. Log in as an administrator.
2. Click the Settings icon located to the right of your name in the top right corner of
the screen (it looks like a cog or gear).
3. Select Account Settings.
4. On the left side of the Account Settings page, select Institution.
5. Under Toggle Features, disable the Q&A toggle switch (it is enabled by default).
6. Click Yes on the confirmation message that appears.
Q&A functionality is now disabled. Users will not see the Questions button in their
classroom toolbar, or the Q&A tab for any section.
9
Administrator User Guide
NOTE: If students had entered questions (and bookmarked them) prior to the feature
being disabled, those questions will still appear in the students' Study Guide. But no
further questions/responses can be entered.
Disabling Course Creation (for external LMS users)
Some institutions that access ALP via an LMS allow (or require) their instructors to create
the courses and/or sections in ALP to which their LMS course links. Many institutions,
however, consider that an Administrator responsibility, where admins create the items in
ALP, allowing instructors to just select the section to link.
However, allowing instructors to create these items in ALP when the Admin has already
created them can cause problems and issues when trying to link the appropriate
sections across systems.
To avoid this possibility, the Administrator can disable the New LTI Section Creation
toggle, so that instructors see only the "Link to a section" page when entering ALP
through the LMS. They will not see any option to create a course or section in ALP.
To disable course creation by instructors across the institution
1. Log in as an administrator.
2. Click the Settings icon located to the right of your name in the top right corner of
the screen (it looks like a cog or gear).
3. Select Account Settings.
4. On the left side of the Account Settings page, select Institution.
5. Under Toggle Features, disable the New LTI Section Creation toggle switch (it is
enabled by default).
6. Click Yes on the confirmation message that appears.
ALP section creation through the LMS is now disabled. Instructors will only see the page
allowing them to select a section to link to. Remember, the sections must exist in ALP
and be assigned to that instructor in order to be selected.
Disabling Automatic Instructor Creation (for external LMS users)
Typically, when an instructor first accesses ALP through their LMS course, the LMS system
passes through their name and email address, and ALP automatically creates the user
as an Instructor in ALP. This ensures that ALP displays the proper items for the instructor
when accessing their ALP courses.
However, some administrators want to maintain stricter controls over user creation in
ALP, and would prefer to create those users in ALP separately rather than automatically
through the LMS.
10
Administrator User Guide
To allow for this, Administrators can disable the New LTI Instructor Creation feature.
When disabled, if an instructor attempts to access ALP through the LMS and ALP does
not have them as a user (based on email address), they receive a "User not found"
error.
IMPORTANT: ALP identifies users via unique email addresses. The email address for the
user in the LMS must match the email address for the user in ALP.
To disable automatic instructor creation from the LMS
1. Log in as an administrator.
2. Click the Settings icon located to the right of your name in the top right corner of
the screen (it looks like a cog or gear).
3. Select Account Settings.
4. On the left side of the Account Settings page, select Institution.
5. Under Toggle Features, disable the New LTI Instructor Creation toggle switch (it is
enabled by default).
6. Click Yes on the confirmation message that appears.
Automated instructor creation through the LMS is now disabled. Administrators must
add the instructors in ALP separately, being absolutely sure the email address for the
instructor is the same in ALP as it is in the LMS. Otherwise the user will receive a User not
found error when accessing ALP.
11
Administrator User Guide
Adding Campuses and Buildings
Rooms in the Active Learning Platform are, logically, located in buildings on a campus.
Campuses and buildings exist simply as a way to filter or locate your rooms. They do not
need to correspond to an actual physical location, though they often do.
Rooms are used for scheduling and to track the location of captures. Each room is
associated with one capture device, so that when the room is identified for a class
schedule, so is the device.
The workflow goes like this:
1. Create a campus.
2. Create one or more buildings for that campus.
3. Create one or more rooms for the building.
4. Add a device to the room.
There are two methods for adding rooms to the Active Learning Platform:


Bulk Import - Use the Bulk Room Import feature to add multiple rooms at once, as
well as create campuses and buildings, using a properly-formatted CSV file.
Manual - Add rooms, buildings, and campuses individually through the interface.
These instructions are below.
Creating a campus and building(s)
You can create a campus and buildings while creating rooms, but for ease of
instruction, the procedures are separated out here. The steps, however, are essentially
the same.
To create a campus and buildings
1. Select Rooms from the main menu.
2. Select Manage Campuses and Buildings from the upper-right section of the
Rooms Management screen.
3. In the dialog box that appears, open the Select a campus drop-down list and
select +Add new campus.
4. Enter a Campus name.
5. Select the Timezone where the campus resides.
6. Click SAVE.
7. Open the Select a building list and select +Add new building.
8. Enter a Building name.
9. Click SAVE.
12
Administrator User Guide
10. Repeat steps 7 through 9 to add more buildings to the campus.
11. Click DONE.
Repeat the above procedure to create other campuses and their associated buildings
as needed.
13
Administrator User Guide
Manually Adding Rooms
When creating rooms, you must select a campus and building for the room. Use the
above procedure to create these items if necessary. Once the system has rooms, you
can assign a device to each room and configure section schedules for each room.
See Bulk Import Rooms for instructions on using a CSV file to import multiple rooms (and
campuses and buildings, if appropriate).
To add rooms through the interface
1. From the main menu, select ROOMS.
2. At the upper right of the Room Management screen, click ADD ROOM.
3. From the list, select the Campus where the room is located.
4. From the list, select the Building where the room is located.
5. In the Room box, enter a name, number, or other identifier for the room.
6. Click SAVE.
The new room appears on the Room Management screen with a big button that says
ADD DEVICE TO ROOM. The room cannot be used for capturing a class until it contains
a device.
14
Administrator User Guide
Create Rooms Using Bulk Import
The room import feature allows you to create many rooms at once in the system, for
multiple campuses or buildings as applies to your situation. You can also create
campuses and buildings via the import.
BEST PRACTICE: Perform an export of the sample rooms.csv file first (see procedure
below), to use as a template for your import. Replace the sample data but leave the
header row. Then import a few rooms at a time (and campuses or buildings if desired),
reviewing your imported data for accuracy. This helps ensure the success of a larger
import.
Using the Import feature requires creating a CSV file that includes the following fields (in
this order):
Column/Field
Description
The campus where the room is located. Required.
Campus
Will be created if the Campus provided does not already
exist. See IMPORTANT note below.
The building where the room is located. Required.
Building Name
Will be created if the building provided does not already
exist. See IMPORTANT note below.
Room
Identifier for the room, such as a room name or number.
Timezone
Timezone for the location of the room. This is used to
properly synch section schedules and lecture captures
performed by the device.
IMPORTANT: If you are adding rooms to an existing campus and building, be sure to use
the exact campus and/or building name in the CSV file; if you enter one that does not
match, a new one is created, and your rooms are associated with the new
campus/building.
To create rooms (and campuses or buildings) from a CSV file import
1. From the main menu, click Rooms.
2. At the top of the Rooms Management screen, click Import Rooms.
3. Click SELECT FILE.
NOTE: Click the Download a sample .csv file link to obtain a properly formatted
CSV file to use as a template.
4. In the Filepicker window, use the left panel to identify the location of the file,
then follow the prompts. If the file is saved locally, click Choose File from the
bottom of the window, and navigate to the .csv file to import.
15
Administrator User Guide
5. Review the progress screen and note any entries that may have an error.
6. Click DONE when the import is complete.
Check the Rooms page for accuracy of the import. Check the Campus and Buildings
lists to review new items created by the import, if applicable.
16
Administrator User Guide
Managing Users
Managing users in the Active Learning Platform involves adding the users to the system,
assigning one or more roles to the users, and if applicable, associating users with one or
more course sections. Furthermore, you can assign each user a particular role for each
section if their default role does not apply. For example, you may have a teaching
assistant who is an instructor for some classes but a student for others.
You can add users to the Active Learning Platform in the following ways:


Bulk Import - Add multiple users at once by importing a properly formatted CSV
file.
Manual - Add users individually through the interface.
Users added to the system can be assigned any of three roles: administrator, instructor,
or student. All users in the system appear on the Users page, accessed from the main
menu.
The Users page lists all the users along with the "state" of the user. The State field
indicates the following:



Invited - User has been invited but has not yet responded.
Active - User responded to the invitation and completed account registration
with the Active Learning Platform.
Inactive - User has been deactivated; user account exists in the system but user
cannot log in. User can be made active again at any time without requiring
them to re-register their account.
17
Administrator User Guide
Manually Adding Users
Adding users involves providing a name and email address for a user, and then
(optionally) assigning one or more roles to them. The user is then sent an invitation to the
email address provided.
If you are creating a user account for an instructor or a student, you are also given the
option to associate that user with one or more existing sections.
To add users individually
1. Select USERS from the main menu.
2. At the upper-right of the page, click ADD USER.
3. Enter First Name, Last Name, and Email address for the user (required).
4. If appropriate, use the sliders to assign one or more roles to the user.
5. If the user is an instructor or student, the box expands to allow you to add
sections to associated with the user. The sections must have already been
created. Click ADD SECTION.
6. Use the drop-down lists to identify the term, course, section, and role the user has
for the section.
7. Click ADD SECTION again to identify another section.
8. When finished, click NEXT.
9. Review the user information on the screen. If correct, click INVITE.
The user will receive an email invitation to Active Learning Platform. The message will
include a link that will allow them to complete system registration including adding or
editing their user profile information.
18
Administrator User Guide
Bulk Import Users
Bulk import allows you to add multiple users at once, and, if desired, to associate those
users to multiple courses and sections using a properly formatted CSV file.
ADDITIONALLY, the user import can also be used to enroll existing users to existing
sections.
The User CSV import can perform three different actions:



Add new users to the system, assigning them the appropriate role(s). New users
added to the system receive an email notification, requesting them to complete
their system registration.
Add new users to the system while also assigning them to one or more sections.
Enroll existing users into sections, with the appropriate role. Users receive an email
notification inviting them to the course.
NOTE that a user can only be assigned to a section with a single role (either
student or instructor). If your import assigns the same user to the same section
with a different role, you will get an error for that row.
NOTE: The term, course code, and section code information must exist in the Active
Learning Platform before assigning users via import.
BEST PRACTICE: Perform an export of the sample users.csv file first (see procedure
below), to use as a template for your import. Replace the sample data but leave the
header row. Then import a few users at a time (with course and section assignments if
desired), reviewing your imported data for accuracy. This will help ensure success of a
larger import.
An example CSV for importing users would look as follows:
Importing users requires creating a CSV file that includes the following fields (in this
order):
19
Administrator User Guide
Column/Field
Description
Role
The role the user has in the system. Valid values include
Admin, Instructor, or Student.
Required.
Last name
Last name of the user.
Required.
First name
First name of the user.
Required.
Email address for the user.
Required.
Email Address
NOTE: If the email address is not present in the system, a
new user will be created. If the user already exists, they are
assigned to the section provided, with the role identified
for this row.
Course Code
Identifier of the course to which the section belongs. The
course MUST already exist.
Optional for creating new users.
Required to enroll users to a section.
Section Code
Identifier for the section to which you are enrolling this
student. The section MUST already exist.
Required if Course Code is present.
Term
The term during which the associated courses and sections
are being offered. The term must already exist; it cannot
be created via import.
Required if Course Code is present.
20
Administrator User Guide
To import users from a CSV file
1. From the main menu, select USERS.
2. From the User Management screen, select Import Users.
3. Click SELECT FILE.
NOTE: Click the Download a sample CSV file link to obtain a properly formatted
CSV file to use as a template.
4. In the Filepicker window, use the left panel to identify the location of the file,
then follow the prompts. If the file is saved locally, click Choose File from the
bottom of the window, and navigate to the .csv file to import.
5. Review the progress screen and note any entries that may have an error.
6. Click DONE when the import is complete.
Check the Users page for the accuracy of the import, and expand each user as
necessary to show any course or sections that were associated with the user via the
import.
New users will receive a notification to access the system and complete their
registration. These users will appear with a status of "Invited" until their registration is
complete. Existing users will receive a notification of their addition to a course.
21
Administrator User Guide
Editing Users
While users can edit their own personal information in the system, you as the
administrator will need to edit the user role or add and remove sections associated with
a user.
Editing users begins opening the USERS page and finding the user(s) you want to edit.
You can make changes to individual users, or bulk changes for a group of users.
You can also deactivate a user. This retains their information in the system, including
analytics, but does not allow them to log in.
To edit a single user
1. From the main menu, click USERS.
2. Use the Search text box or the Filter drop-down lists to find the user(s) you need
to edit. You can also sort the list by clicking a column header.
Notice the chevron (down arrow) to the right of each row. This opens a menu of
options for that user.
3. Click Edit Profile.
The Edit User panel appears, allowing you to edit the First name, Last name,
Email address, Phone number and assigned role(s).
22
Administrator User Guide
4. When finished, click SAVE.
For information on adding or editing section enrollments for a user, see Assigning Users
to Sections.
Depending on the current status of the user, your other options will include Resend
invite (for Invited status users), Make active (for currently Inactive users), and Make
inactive (which retains user information in the system but does not allow user to log in).
IMPORTANT: You cannot deactivate a user if they are the only instructor for any sections
or the primary instructor for scheduled captures. You must assign a different instructor to
those sections/schedules first. Similarly you cannot change the section role to Student
for the sole instructor on a section.
Editing multiple users (bulk-edits)
There are a few functions you can perform on a group of users at once, including resending invites, bulk-role changes, or bulk-deactivation.
To bulk edit multiple user
1. From the main menu, click USERS.
2. Use the Search text box or the Filter drop-down lists to find the user(s) you need
to edit. You can also sort the list by clicking a column header.
3. Click a check into the checkboxes of the users you want to edit. If your filter
returned ONLY the users you want to edit, use the checkbox at the top of the list
to check all users.
Notice that the top of the Users list changes, to show the bulk-editing options for
the users you selected.
4. If all of the selected users are in the Active state, the Active slider is available to
make the selected users Inactive. (The opposite is also true; if all selected users
are Inactive, the slider can be used to make them Active.)
5. If all the selected users are in the Invited state, the Resend invite button is
available, to resend system registration email to those users.
23
Administrator User Guide
6. To re-assign roles to ALL SELECTED USERS, enable or disable the role sliders, then
click CHANGE ROLE.
7. Review the confirmation dialog box closely, to be sure you want to
assign/revoke the roles from ALL of the selected users.
8. Click OK to confirm the role change(s).
Users will receive an email notifying them of their role change in the system.
VERY IMPORTANT!! The Role sliders identify which role(s) will be assigned to the selected
users AS WELL AS which role(s) will be revoked. If the selected users currently have
multiple roles, and you have enabled only one of the sliders, those users will have ONLY
the selected role assigned. This also means that their enrollment in any courses as the
other role-type is automatically revoked. This is stated in the confirmation message you
receive.
24
Administrator User Guide
Adding and Editing User Enrollments
Associating a user with a section allows that user to access the online classrooms and
posted materials for the section.
You can also assign a role for the user for a particular section. The role the user has for
the section determines which materials the user can access, and which actions the user
can perform on the materials.
OPTION: You can use the Users Import to bulk-assign users to sections. Each user/section
enrollment combination must reside on a separate row of the CSV file. See Bulk
Importing Users for details.
For example, a user who is typically a student in the system, and accesses classroom
materials as a student, may also be given a Teaching Assistant role for some classes. In
this case, the same user could be assigned as an instructor for those sections, and be
able to work with the section materials the same way an instructor would. A user
CANNOT have multiple roles for a single section; they must be either a student or an
instructor for a particular section.
Tip for Users: Users can switch the sections they see based on user-role by clicking their
Name in the ALP window, then clicking Change. This allows them to select a different
role for the institution, showing them their assigned sections for that role.
When a user should no longer have access to a section, you can revoke their section
enrollment.
To associate sections with a user
1. Find the user you want in the USERS page.
2. Click the chevron (menu-arrow) located on the right-side of the user's entry in
the list, and select Enrollments.
The enrollments panel appears, listing the sections, if any, to which the user is
currently associated, and their role.
3. Use the filter lists across the top of the enrollments panel (shown below) to
identify the section to associate with the user.
25
Administrator User Guide
4. Use the Role drop-down list to identify the role this user has for that section. You
can change this after assigning the section, if needed.
5. Click ENROLL to assign the user to that section.
6. Repeat the steps above to add the user to another section.
7. If necessary, to change the user's role for an assigned section, click the chevron
for a section, then select Make student or Make instructor as appropriate.
8. Click DONE when finished.
Revoking sections or changing section role
The Enrollments panel allows you to change the role a user has for an assigned section
(Student or Instructor), as well as revoke section access.
IMPORTANT: You cannot revoke section enrollment for a user if they are the only
instructor for the section. You must assign a different instructor to those sections first.
Similarly you cannot change the section role to Student for the sole instructor on a
section.
To revoke sections or change user role for a section
1. Find the user you want in the USERS page.
2. Click the chevron (menu-arrow) located on the right-side of the user's entry in
the list, and select Enrollments.
The enrollments panel, shown above, lists all sections associated with the user.
3. Click the chevron for a section, giving you the following options:
o
o
Click Revoke to remove that user from the section.
Click Make student or Make instructor (based on the current user-role
for the section) to assign a different role for that section.
26
Administrator User Guide
4. Repeat the above steps to make changes to other assigned sections for the
user.
5. When finished, click DONE.
27
Administrator User Guide
Creating Terms
Terms are used to group course offerings by academic term (semester, trimester,
quarter, etc). They allow you to define a date range for the term, as well as define
Exception dates during which classes are not held, such as holiday breaks or scheduled
exam dates.
If a section's capture schedule has captures that fall on dates defined as Exception
dates, those captures will not occur.
Terms must be created through the UI; they cannot be created via CSV import.
Furthermore if using imports to create sections or assign users to sections, the term must
exist before it can be identified in the import.
To add a new term
1. From the main menu, select COURSES.
The course catalog appears.
2. At the upper-right section of the page, click ADD TERM.
3. Enter a term Name.
4. Enter a Start Date and End Date for the term.
5. Click Add Exception.
6. Enter the Start Date and End Date for a date or period within the term when
regular classes are not to be held, such as holidays or exam dates. Use format
YYYY-MM-DD (e.g., 2014-09-01).
7. If necessary, click Add Exception to include another date or range to exclude.
8. Click SAVE.
Note about Exception Dates: When creating a recurring scheduled capture for a
section, any captures slated for exception dates are not generated. You can, however,
create one-time captures for a section to occur on an exception date. The system
assumes you are aware of the exception date when you create the one-time section
capture.
28
Administrator User Guide
Creating Courses
Courses are instructional offerings typically offered by an organization or department. In
any given term there may be multiple offerings of the same course, which are
represented as sections.
Courses simply act as "containers" for one or more sections of a class.
There are two methods for creating courses in the Active Learning Platform:


Bulk Import - Create multiple courses (and sections if desired) by importing a CSV
file. See Creating Courses/Sections via CSV Import.
Manual - Add courses individually through the interface. These steps are below.
Courses are created through the COURSES page, accessed from the main menu. You
may associate each course with an organization and/or a department but this is
optional. You can also make or change this association later if necessary.
To create a course
1. From the main menu, click COURSES from the main menu at the top of the page.
The course catalog appears.
2. Click ADD COURSE.
3. Enter a Course code. Example, ENG-201. This must be unique to the institution.
4. Enter a Course name that describes the course.
Example: Introduction to Linguistics.
5. Optionally: Use the lists to select an Organization and/or a Department to which
to associate the course.
6. Click SAVE.
At this point, you can repeat the above steps to create more courses, or create
sections for the new course.
29
Administrator User Guide
Creating Sections
In any given term there may be multiple offerings of the same course, which are
represented as sections. Sections get scheduled and those scheduled occurrences of
the section are the classes students attend.
For example, the English Department offers the Composition 1 course, ENG-COMP1, for
which there are three different scheduled offerings defined as Sections ENG-COMP101,
ENG-COMP102, and ENG-COMP103.
For some institutions, a course and a section are considered the same thing. Or for
many courses, there may be only one section. In these cases, there will still be both a
course and a section, but you would configure only one section per course.
There are two methods for creating sections in the Active Learning Platform:


Bulk Import - The course CSV import allows you to create courses and sections at
the same time, as well as allowing you to create sections for existing courses. See
Creating Courses/Sections via CSV Import for more information and instructions.
Manually - Add sections individually through the interface. These steps appear
below.
To add sections through the interface
1. From the main menu, click COURSES.
The course catalog appears.
2. Create a new section in one of the following ways:


At the top of the screen, click New Section, OR
Find the appropriate course in the list (search, filter, or scroll through), then
click the New section icon (plus sign) located to the right of the course
name.
3. In the Create new sections page that appears, select a Course from the dropdown list.
30
Administrator User Guide
If you clicked the plus sign for a course, this is pre-populated with that course.
4. Choose a Term during which this section will be scheduled.
5. To clearly identify the section, enter a section code. The section code must be
unique to the course/term.
6. From the list, select an instructor. NOTE that the first instructor you assign to the
section will automatically be made the Primary Instructor for the section.
7. To add another section, click ADD SECTION and complete the section code and
instructor fields.
8. If you need to remove a section from those listed, click the X button next to the
section you want to delete.
9. Click SAVE.
31
Administrator User Guide
Creating Courses and Sections via CSV Import
The Course import feature allows you to create multiple courses and/or sections at
once, using a properly formatted CSV file. As noted in the table below, the course
import can also be used to create organizations and departments.
IMPORTANT: If you are assigning courses to an existing organization or department
(which is optional), be sure the CSV file contains the exact organization and/or
department name; if you enter one that does not match, a new one is created, and
your courses and sections are associated with the new organization/department.
Because Course ID must be unique to the institution, these would have to be deleted
before new ones (for the proper org/dept) could be created.
This also applies to creating sections for existing courses; be sure the Course ID you enter
exactly matches the existing course for the new sections.
The course import CSV file can include the following fields (in this order):
TIP: Navigate to the COURSES page and click Import courses. Click the Download a
sample .csv file link to obtain a properly formatted CSV file to use as a template.
Column/Field
Description
The organization to which the department offering the course
belongs.
Organization
Optional
 Will be created if the organization provided does not
already exist.
The department offering the course.
Department
Optional
Will be created if the department provided does not
already exist.
ID number for the course. Example: ENG-201.
Course ID






Required
Will be created if the Course ID provided does not already
exist.
Must be unique for the institution.
32
Administrator User Guide
Column/Field
Description
Plain text name for the course. Example: Introduction to
Linguistics.
Required
 If creating courses, the name entered is used and is not
editable once the course is created.
 If creating sections for existing courses, the Course ID is
used to identify the course, so this field does not have to
exactly match the existing course name, but this field must
not be blank.
Term during which the section is to be offered.

Course Name
Required to create sections, AND must already exist (have
been created through the UI).
 Optional for creating courses (courses are not associated
with Terms)
Identifier for the section. Example: ENG-LING-201.

Term
Section ID
Required to create the section.
 Must be unique to the Course/Term.
Email address of the primary instructor for the section.


Primary
Instructor Email

Required to create the section.
User will be created if the address does not already exist in
the system.
User will receive an email invitation to register with Active
Learning Platform.
Email addresses of any additional instructors who must have
access to the section.
Secondary
Instructor Emails



Optional
Separate multiple addresses with semi-colons.
User will be created as an Instructor if the address does
not already exist in the system.
User will receive an email invitation to register with Active
Learning Platform.
To create courses or sections from a CSV file import
1. From the main menu, click Courses.
The course catalog appears.
2. At the top of the screen, click Import Courses.
3. Click SELECT FILE.
TIP: Click the Download a sample .csv file link to obtain a properly formatted CSV
file to use as a template.
33
Administrator User Guide
4. In the Filepicker window, use the left panel to identify the location of the file,
then follow the prompts. If the file is saved locally, click Choose File from the
bottom of the window, and navigate to the .csv file to import.
5. Review the progress screen and note any entries that may have an error.
6. Click DONE when the import is complete.
Check the Courses page for accuracy of the import, and expand to show any sections
that were also created from the import. You may also want to review the organizations
and departments created by the import, if applicable.
34
Administrator User Guide
Scheduling Sections
Configuring scheduled captures for a section accomplishes four things:




Creates classes for the section, acting as a placeholder or container for the class
capture and any other materials the Instructor may want to share with the
students.
Identifies the dates and times when captures will occur.
Identifies the room where the classes will occur, which in turn identifies the
device that will do the capturing.
Can enable Live Streaming for the section, allowing students to watch the class
in real-time. See Configuration Requirements for Live for additional information
on configuring live streamed classes.
View, create, or edit the capture schedule for a section by expanding the course on
the COURSES page, then clicking the Calendar icon for the section. ALTERNATELY, you
can use a CSV import to schedule captures for sections.
NOTE: The maximum duration of any scheduled capture is 4 hours. This limit is enforced
by the system.
To schedule captures for a section
1. Select COURSES from the main menu and navigate to the course whose section
you want to schedule (search, filter, scroll through).
2. Click the calendar icon located on the right side of the section entry, as shown
above.
The schedule capture window appears, with the Title and Instructor fields
35
Administrator User Guide
populated with the information for the selected section.
3. Use the drop-down lists to select the Campus, Building, and Room where the
classes will occur.
4. If necessary, select a different Instructor for this class. The instructor for the section
appears by default.
5. Enter a Guest Instructor name if applicable. This does not have to be a user in
the system.
6. Enter the start and end time for each class.
7. Select Weekly from the Repeats drop-down list if you are scheduling recurring
classes for the section.
The window changes to show additional scheduling options.
8. Enter a Start date and End date for the class. These dates likely coincide with the
beginning and end dates for the Term. See the NOTE below regarding term
exclusion dates.
9. Enter the weekly frequency for the class. For example, for a class that occurs
every week, enter 1. For a class that occur every other week, enter 2, and so
forth.
10. Use the sliders to identify on what days(s) of the week the class occurs.
As you make changes, the calendar preview changes to reflect the schedule
information entered on the page. Today's date is transparent and circled;
36
Administrator User Guide
scheduled capture dates are marked with colored circles.
11. Expand the Options (click the triangle icon on the right side of the Options
banner).
12. Select whether to Auto-Publish the capture(s). If enabled, the capture is
published to the section as soon as it is processed. If not enabled, the primary
instructor (or the admin) will need to manually publish the capture later for users
to view it.
13. Select whether to enable Closed Captioning for this capture. This option only
appears if you have closed captioning configured for the system.
14. Select whether these classes will be available via Live Stream. This simply means
that students can watch the class in real time from a remote location, viewing
the classroom during the class time.
NOTE: This option ONLY appears if the selected Room contains an SCHD.
15. Review and set or change the A/V sources and capture quality. The defaults set
for the device appear initially but can be changed as needed.
16. When finished, click SAVE.
37
Administrator User Guide
NOTE: Any exclusion dates configured for the term (i.e., school holidays or exam dates)
will apply to all schedules created for sections during that term. This means that no
captures will occur on exclusion dates where the scheduled capture and the exclusion
date overlap. The Admin view of a scheduled capture on any given day may show a
scheduled capture, but the calendar view on the scheduled capture page will not
have a dot on the exception dates. in addition, classes are not automatically created
on exception dates.
You CAN schedule one-time captures to occur on exception dates (the system
assumes you know it is an exception date when you select it for a one-time capture).
Alternately you can configure a capture to occur outside of a section, then publish it to
a class after it is processed. See Adding Captures to configure recurring non-sectionbased captures to occur on exclusion dates.
38
Administrator User Guide
Scheduling Section Captures via CSV Import
The Scheduled Capture import feature allows you to schedule multiple captures at
once. These can be regularly scheduled classes for sections, or standalone captures
that exist outside of configured sections.
Field values must already exist: The schedule import is used to create schedules but
cannot be used to create other system components. Therefore the following items must
already exist in the system before running the import: Campus, Building, Room (and the
room must have a device assigned), Term, Course ID, Section ID, and any Instructors
you want to use as the primary instructor for the schedule (user must have the Instructor
role assigned).
The schedule capture import CSV file can include the following fields (in this order):
TIP: Navigate to the CAPTURES page and click Import captures. Click the Download a
sample .csv file link to obtain a properly formatted CSV file to use as a template.
BE ADVISED however, that opening the CSV file in Excel may display the date format as
mm/dd/yyyy (even though the CSV file has yyyy-mm-dd). You will have to reformat the
Start Date and End Date columns with a custom yyyy-mm-dd format before saving your
completed CSV file. See Formatting Dates for CSV Imports.
Column/Field
Campus
Back to top
Building
Back to top
Room
Back to top
Start Date
Description
The campus where the room being scheduled is located.
Required
 Must already exist
The building where the room being scheduled is located.

Required
Must already exist
Room where the capture will occur.


Required
 Must already exist
 Must have a capture device assigned to it
 Room name is case sensitive and must match the existing
room name
Date the capture will first occur



Back to top

Required
Must be in ISO date format: yyyy-mm-dd. Help! My date
format is wrong!
If a non-repeating capture, will be the only date entered (the
date of the capture).
39
Administrator User Guide
Column/Field
Description
Time of day the capture is to begin.
Required
 Must be in ISO time format: hh:mm:ss
 Must have two digits for each segment, and must not include
am/pm.
Example #1: 14:30:00 identifies the capture start time as 2:30pm.

Recording
Start Time
Back to top
Example #2: 9:00:00 is invalid and will be rejected; 09:40:00 is a valid
format.
Time of day the capture is to end.
Required
 Must be in ISO time format: hh:mm:ss
 Must have two digits for each segment, and must not include
am/pm.
Example #1: 16:30:00 identifies the capture end time as 4:30pm.

Recording
End Time
Back to top
Example #2: 9:00:00 is invalid and will be rejected; 09:40:00 is a valid
format.
Identify the inputs to be used for this capture.
Required
 Valid values include (multiple inputs separated with a pipe |
symbol):
o A - audio, which is always captured and does not need to
be identified unless it is the ONLY input you are capturing.
o D1 - display only using input 1
o D2 - display only using input 2
o V1 - video only using input 1
o V2 - video only using input 2
o D1|D2 - capture dual display
o D1|V2 - capture display on input 1 and video on input 2
o V1|D2 - capture video on input 1 and display on input 2
o V1|V2 - capture dual video
EXAMPLE: The capture inputs you want are audio, display, and video
(ADV), where the video camera is connected to input 1 and the
display monitor is connected to input 2 of the capture device. In this
case, the entry here would be V1|D2 (V1-pipe-D2). You could also
have V1|D2|A, but in this case A has no effect as audio is always
captured.

Inputs
Back to top
40
Administrator User Guide
Column/Field
Description
The plain text title for the capture.
Optional but STRONGLY recommended. With no title, the
capture will be difficult to find/identify in a captures list. You
or the instructor can always edit the name of the capture
later.
 For recurring section-based captures, you may want to
identify the section (section code and/or section name) for
which the capture is being generated.
Course code that contains the section for which this capture is
being generated.

Title
Back to top
Course Code
Back to top
Section
Code
Back to top
Required for section-based capture schedules
 Must match a Course Code already in the system
 Used to validate the section code, to properly apply/publish
the capture
Section code for the section for which this capture is being
generated.

Required for section-based capture schedules
 Must match a Section Code already in the system
 Used to identify the section, to properly apply/publish the
capture
Term during which this section's capture is being generated.


Term
Back to top



Required for section-based capture schedules
Must match a Term already in the system
Used to validate the section code, to properly apply/publish
the capture
Exclusion dates configured for the term will apply to a
recurring capture schedule
41
Administrator User Guide
Column/Field
Description
Email address of the primary instructor for the section.



Instructor
Email
Back to top

Required if no section is identified for the capture.
Optional if a section is identified. If left blank, the Primary
Instructor for the section will be applied.
The Instructor becomes the "owner" of the capture media; it
appears in their LIBRARY, they can edit the media and
details, and publish it to additional sections or users as
needed.
If NOT left blank, the user must already exist in the system,
and have the Instructor role.
IMPORTANT: For non-section-based captures, the completed
capture will only appear in the Instructor's LIBRARY page (and in the
Admin's CAPTURES list). In this case, the capture will require manual
publishing or sharing by the instructor or admin in order for any other
users to view it.
Guest
Instructor
Email
Back to top
Email address of any guest instructors who must have access to the
section.
Optional
User will be created as an Instructor if the email address does
not already exist in the system, and receive an email
invitation to register with Active Learning Platform.
Whether or not this is a recurring schedule.



Repeating
Back to top



Optional
Valid values are Yes or No
If field is blank, No is applied and capture occurs only on the
date identified in Start Date field.
If Yes is entered, Repeat Pattern and End Date fields (below)
are required.
42
Administrator User Guide
Column/Field
Description
The days on which this scheduled capture is to occur.
Required IF Repeating field is set to Yes.
 Valid values include (use any combination; separate multiple
days with a pipe | symbol):
o M or Monday
o T or Tuesday
o W or Wednesday
o R or Thursday
o F or Friday
o S or Saturday
o U or Sunday
EXAMPLE: A repeating capture is to occur on Mondays,
Wednesdays and Fridays. Valid values for this field would be
Monday|Wednesday|Friday or M|W|F or a combination such as
Monday|W|Friday.

Repeat
Patterns
Back to top
The last date on which this scheduled capture is to occur.
End Date
Back to top
Required if Repeating field is set to Yes.
 Leave blank for non-repeating captures
 Must be in format yyyy-mm-dd. Help! My date format is
wrong!
Whether or not the capture is to be automatically published to a
class.

Optional
 Valid values are Yes or No
 If the field is blank, Yes is applied, and captures are autopublished to the section after completion.
 If set to No, the capture will appear only in the primary
Instructor's library and will need to be manually published to a
class for student access.
 Has no effect for non-section based captures; captures can
only be published to a section.
Identifies the capture quality.

Auto
Publishing
Back to top
Quality (HD
or SD)
Back to top



Optional
Valid values are HD or SD
If the field is blank, HD (high-definition) is applied.
43
Administrator User Guide
Column/Field
Description
Identifies whether this capture is to be live streamed.
Optional
 Valid values are Yes or No
 Applies ONLY to section-based capture schedules
 If the field is blank, No is applied, and the capture is not
streamed live.
 If set to Yes, the room selected MUST have an SCHD device in
it. See also Configuration Requirements for Live
Identifies whether this capture is to be closed captioned. Applies
only if you have closed captioning configured for the institution.

Live Stream
Back to top
Closed
Captioning

Back to top



Optional
Valid values are Yes or No
Applies ONLY to section-based capture schedules
If the field is blank, No is applied, and the capture is not
captioned.
To create scheduled captures via CSV import
1. From the main menu, click CAPTURES.
2. At the top of the screen, click Import Captures.
3. Click SELECT FILE.
TIP: Click the Download a sample .csv file link to obtain a properly formatted CSV
file to use as a template.
4. In the Filepicker window, use the left panel to identify the location of the file,
then follow the prompts. If the file is saved locally, click Choose File from the
bottom of the window, and navigate to the .csv file to import.
5. Review the progress screen and note any entries that may have an error.
6. Click DONE when the import is complete.
For section-based captures, you can check the COURSES page, finding the sections
and making sure the scheduled captures appear.
Otherwise, click the Scheduled status at the top of the CAPTURES page to review the
scheduled captures created by the import. You may need to filter the list using the filter
options on the left side of the page.
44
Administrator User Guide
Formatting Dates for CSV Imports
Some of the CSV imports available for ALP contain date fields, in particular the
capture/schedules import. The required format for date fields is yyyy-mm-dd. This is an
international standard date format, designed to reduce confusion.
Users (like you) typically work with CSV files using a spreadsheet program like Microsoft®
Excel. The PROBLEM is that Excel may automatically reformat what it recognizes as a
date into the default date format configured for your system. Which may not be yyyymm-dd.
What this means is that even if your CSV file is correct (open it in Notepad or Wordpad
to see the raw data), the reformatted date field will look wrong in Excel. And after you
make changes and save the CSV file, the date format showing in Excel will be applied
to the fields.
This is bad, because now your CSV import won't work.
DON'T PANIC! Use the instructions below to change the date format in your
spreadsheet.
Don't be a slave to date formats! Enter your schedule/capture data into the
spreadsheet using whatever date format YOU like. Then use the below procedure to
reformat the dates columns into the format required for the CSV import. Be sure to save
the file both as a CSV and an Excel file (.xls or .xlst) to retain the formatting change.
To reformat the date fields in an Excel spreadsheet
1. Open the .csv file in Excel.
2. RIGHT-CLICK the tile above the Start Date column header. (Press control+click if
using a Mac)
This selects the entire column and opens a shortcut menu as shown below.
3. Select Format Cells from the shortcut menu.
4. If necessary, select the Number tab (it should appear by default).
45
Administrator User Guide
5. Select Custom from the number Category list.
6. In the Type field, replace the text that appears with yyyy-mm-dd.
7. Click OK.
8. Repeat these steps for the End Date column.
9. When finished, Save the file as an Excel file (.xls or .xlst), then Save As a .csv file.
The saved CSV file will have the proper date formatting for importing to ALP; the Excel
file will retain the format changes and can be used again later to generate a new
schedule import file.
If you want to be CERTAIN the CSV file is correct, open the file in Notepad or Wordpad
and look for the date; if you changed the format in Excel to yyyy-mm-dd and saved as
CSV, the date will appear in this format in the raw csv file. Don't use Excel to check it;
Excel will convert the dates back to the system default format.
46
Administrator User Guide
Configuration Requirements for Live Streaming
Live streaming simply means that users can remotely watch a class as it is
happening. For Live streamed classes, the input being captured by the capture device
is webcast in real-time to those users viewing the classroom through ALP.
For live streaming to work properly, there are a few configuration requirements. Don't
worry; they're pretty straightforward.
Live streaming is only available for section captures
When you schedule a capture for a section, the Options available include a Live
stream toggle. When you try to add or schedule a capture outside of a section
(Captures page > Add Capture), you don't get this option.
Why?
Well, it has to do with the fact that users (students) can only access media that exists in
a class. The view it by clicking GO TO CLASSROOM. So if you want people to view LIVE
streams, it has to go into a class, in a section.
Remember also that to get into a section, you have to be assigned to the section.
Meaning a user who isn't assigned to the section can't see the classes for the section, so
they can't GO TO CLASSROOM.
So, while we could let you configure a live stream for a capture that isn't associated
with a section, how would users get there? How would they find the "GO TO
CLASSROOM" button for the live class?
What you CAN do, however, is configure a dedicated course and section for holding
special events or other happenings that you want to stream live to a larger institutional
audience. Then assign all of the users you want to that section.
Live streaming requires an SCHD or Echo360 PRO appliance
Only classes that occur in rooms where a SafeCapture HD (SCHD) or Echo360 PRO is
configured to capture can be used for live streaming. Keep this in mind when you are
scheduling captures for the section. Be sure to select a room that uses an SCHD or PRO
for capture.
Check and configure outbound port communications
Live streaming is provided through hosted streaming (Wowza) servers. These servers
receive the separate input streams from the appliance via RTP (real-time transfer
protocol), then deliver the consolidated media stream back to users.
47
Administrator User Guide
In order to make this work, the capture appliance needs to be able to communicate
with the streaming servers through the appropriate ports, and those ports need to be
configured, via wildcard DNS entries, to point to the cloud-based Wowza servers.
For details on this, see Port Configuration for LIVE Streaming.
48
Administrator User Guide
Working with Devices
Capture devices record classroom activities and upload those recordings for
processing and publishing to students. The two types of classroom devices are:


SafeCapture HD (SCHD) - Fully automated capture hardware that records class
content and uploads the recordings for processing and publishing. For
installation and configuration details for the SCHD, see
Classroom Capture - Software installed on classroom or podium PCs that can
capture video, computer screen, and audio input from the classroom. Like the
SCHD, it automatically uploads the recordings for processing and publishing.
Personal Capture is a capture method but is not considered a device for the purposes
of associating with a classroom or class schedule.
Log On and Monitor Device
Once initialized and assigned to a room, you may want to log on to the device and
monitor it to check that the appropriate inputs are working and providing capture
information.
You can use the below procedures to monitor a device while idle or during a capture if
necessary.
To log on to the device and monitor activity
1. From the main menu, select ROOMS.
2. Find the room with the device you want to monitor. Use the filtering lists at the
top of the screen to narrow which rooms are shown.
3. Click the Log in to Device icon, located in the bottom-left corner of the Room
block.
4. Log in to the device using the device login information configured for the
device.
5. Use the tabs to select the device information you want to review. The Monitor
tab allows you to view the configured inputs to see what they are capturing.
6. If you are monitoring inputs, click Stop Monitoring when you are done.
7. When you are finished reviewing device information, click Logout, located in the
upper-right corner of the tabbed section of the page.
Filtering Rooms by Device Status
The filtering lists at the top of the Rooms Management page allow you to limit which
room blocks are shown based on their location (campus, building) or by type (SCHD,
Classroom Capture).
49
Administrator User Guide
You can also "favorite" any rooms that may require special attention, to show those
specifically as needed. Click the star icon located to the left of a room/device name to
favorite or un-favorite a room.
Each of the room blocks also show the current status of the device assigned to the
room: capturing, idle, offline, or unconnected.
To list rooms based on device status
1. Select Rooms from the main menu.
2. Click the Switch to list view icon, located on the right side of the screen, directly
below the Add Room button.
The Rooms Management screen changes to list device status as banners that
can be expanded. Along with each status label, there is a number that indicates
how many rooms/devices are in that state.
3. Click the triangle to the left of each status label to expand the device list and
show all devices with that status.
4. Hover over each device row to show the drop-down arrow on the far right side
of the row. Click the drop-down arrow for a menu of options for the device.
50
Administrator User Guide
Configuring Capture Devices
The workflow for getting devices ready to capture follows:
1. Configure room/device settings (for SCHD and PRO devices).
2. Download the configuration file to a thumb drive.
3. Install the SCHD, PRO, or Classroom Capture software in the room where the
classes and captures will occur.
4. Note the MAC address of the SCHD, PRO appliance, or the PC where Classroom
Capture is installed.
5. Apply the downloaded device configuration file to the SCHD or PRO device as
appropriate.
6. In the Active Learning Platform, assign the device to the room where it is
installed.
7. Log on and monitor the device to be sure the proper input feeds are working
properly.
Setting up SCHD and PRO devices
Configuring SCHD/PRO appliances involves placing the device into the classroom and
making the proper video, audio, network, and other connections. Then you must load
the Active Learning Platform device configuration file (that you download using the
procedure below) to the device. This allows the Active Learning Platform to recognize
and initialize the device for use.
TIP: If multiple capture appliances (of the same type) use the same device
configurations (audio, video, display, login, etc.), you can use the instructions below to
configure and download the device.xml file once and use it for all devices that share
that configuration.
To set up an SCHD or PRO appliance
1. Insert a USB thumb drive into the computer you are using; this will be where you
save the device configuration file (device.xml).
NOTE: We recommend you use an Echo USB thumb drive that came packaged
with the appliance. Otherwise be sure you are using a FAT formatted thumb
drive.
2. In the Active Learning Platform, click the Settings icon in the upper-right of the
screen (it looks like a gear).
3. Select Configurations from the list.
4. Select the Device default configurations tab.
51
Administrator User Guide
5. From the banner across the top, select the type of appliance you are
configuring (SCHD or PRO).
6. Configure or make changes to the recording device inputs and other settings.
See SCHD Input and Device Settings or Echo360 PRO Capture and Device
Settings as appropriate for details.
These can be changed later for individual devices, using the Configure option
on the ROOMS page tile for a device.
7. Click SAVE.
8. Click Common Settings from the tabs on the top of the page, to configure
the device logins, outbound proxy, or other settings.
9. Scroll to the bottom of the Common Settings page and click SAVE.
10. Click DOWNLOAD.
11. Save or move the downloaded device.xml file to the ROOT location on the
thumb drive (NOT in a sub-folder).
DO NOT change the name of the file.
12. Go to the capture appliance. If necessary, turn it on and make sure it has fully
initialized (wait about five minutes).
13. Insert the thumb drive containing the device.xml file into the USB port of the
appliance. Allow the device to upload and process the configuration file before
removing the thumb drive.
IMPORTANT: Note the MAC address of the SCHD Device appliance; you will
need this to add the device to a room.
14. Repeat the last two steps for each device that will be using the downloaded
configuration settings.
Once the appliance uploads and processes the file, the following things happen:


The appliance establishes communications with the Active Learning Platform.
Once that process is complete, the device can be assigned to a room.
The appliance writes a status file back to the thumb drive containing useful
information about the device (such as IP address), which can be used for
troubleshooting if necessary.
Setting up Classroom Capture devices
1. From the classroom PC where you will be installing Classroom Capture, navigate
to and log into the Active Learning Platform (as an administrator).
2. Click the Settings icon in the upper-right of the page (it looks like a gear).
3. Select Downloads from the list.
4. Select the Windows Download link for Classroom Capture.
52
Administrator User Guide
5. Launch the downloaded executable and proceed through the installation
wizard.
IMPORTANT: Note the MAC address of the computer on which you are installing
Classroom Capture; you will need this to add the device to a room. A window
appears at the end of installation showing the MAC address of the device.
Once installation completes, the Classroom Capture installation establishes
communications with the Active Learning Platform instance from which the installation
executable was downloaded. This allows the installation to be assigned to a room as a
capture device.
53
Administrator User Guide
Common Settings - Device Defaults
All capture appliances have settings common to all devices. These include identifying
the time server being used to keep the devices in sync, and the generic logins that can
be used to access the devices through the Device Web UI.
While initially configured on the Device default configurations page, these settings, like
all other device settings, can be changed on individual devices via the ROOMS page.
To configure common device settings
1. Log into ALP as an administrator.
2. Click the Settings icon in the upper right corner of the page (it looks like a gear).
3. Select Configurations from the settings menu.
4. From the left side of the Configurations page, click Device default configurations.
5. Select Common Settings from the top of the page.
6. The Local administrator login and Local instructor login are automatically
populated with generic usernames and passwords for each ("admin" or
"instructor" and "password").
Enter different values for each, enabling the Show Password slider if needed.
54
Administrator User Guide
The values entered can be used to log into any device to which this device
configuration is applied.
7. Select which Protocol or Protocol/Port combination you want the devices to use
for communication and capture upload.
8. Select whether you want the device to use an Outbound Proxy.
9. If an outbound proxy is selected, enter the Host and Port for the proxy, and the
Username/Password to use for Authentication if appropriate (fields shown in
above figure).
10. When finished, click SAVE.
11. To save your updated device configuration file to a USB thumb drive, click
DOWNLOAD.
You can now insert the thumb drive into any capture device to apply these
configurations to the device.
55
Administrator User Guide
Assigning a Device to a Room
Devices are added to rooms, and each room has one and only one device. When the
room is selected for a capture, either standalone or for a section schedule, that
selection also tells that device to capture that class, on that day, at that time.
When rooms are first added to the Active Learning Platform, they are shown with a big
button that says ADD DEVICE TO ROOM so you are sure to do so.
NOTE: You must know the MAC address of the device installed in the room in order to
select it for a room.
To add a device to a room
1. From the main menu, click ROOMS.
2. Find the room you want to add the device to. Use the filtering lists at the top of
the screen to narrow which rooms are shown.
3. Click ADD DEVICE TO ROOM.
4. From the Device list, select the device you want to add to the room. Devices are
listed by MAC address of the device.
5. Click SAVE.
56
Administrator User Guide
Editing Individual Appliance Configurations
Making device configuration changes for specific devices is done from the ROOMS
page. This is because:


Rooms and devices are linked in a one-to-one relationship; for the Active
Learning Platform, a room and a device are effectively the same.
Device configuration changes are most often needed because of equipment or
environmental changes specific to the room.
NOTE: Changing the device configuration in ALP changes the device.xml file loaded on
the device. If you ever re-upload a different device configuration, these changes will
be lost.
To change device configuration for a single device
1. From the main menu, select ROOMS.
2. Find the room with the device you need to change. Use the filtering lists at the
top of the screen to narrow which rooms are shown.
3. Click the chevron (small arrow) located in the upper-right of the Room tile. You
may need to hover your mouse over the tile to see the arrow.
4. Select Configure.
5. Edit the device settings and click SAVE.
Your input and configuration choices depend on the type of capture appliance
assigned to that room. See Echo360 PRO Capture and Device Settings or SCHD Input
and Device Settings as appropriate.
If you are editing a PRO device configuration, you have an additional Network Settings
option that allows you to select the IP Mode for the device. Since this is done on an
individual-device basis, this option does not appear in the Device default configuration
for the Echo360 PRO. IP Mode can also be changed using the Menu options, accessed
through the front panel of the PRO appliance.
57
Administrator User Guide
The device configuration from the ROOMS page also allows you to download these
changes to a device.xml file which can then be applied to other devices. See
Configuring Capture Devices for information on uploading a configuration file to an
SCHD or PRO appliance.
58
Administrator User Guide
Viewing Device and Room Status
Devices are associated with rooms as a 1:1 relationship. Click ROOMS from the main
menu to view the status of configured rooms and the devices associated with them.
By default, the Room Management page initially appears in "tiled" view. This allows for a
quick-glance status assessment of the rooms listed. See Understanding Device Status for
details on what the tiles show.
Click the list button, located on the right side of the page, to change to a "list by status"
view.
Click the arrow icon to the left of each status to expand the list and see the rooms and
devices identified with that status.
Use the filter drop-down lists across the top of the page to identify which rooms/devices
to list specifically.
Room/Device Statuses on the list-view page are defined as follows:

Favorites - Lists all rooms you have "favorited" (clicked the star) regardless of
status.

Capturing - As the status implies, these are the rooms/devices actively capturing
at the moment.

Idle - Lists all rooms where a device is connected and ready to capture but is not
currently capturing.

Offline - Lists all rooms where the assigned device is not communicating with ALP
(is offline). The device may be powered down at the moment or may have lost
its network connection. See Understanding Device Status for additional
information.

Unconnected - Lists all rooms that have been added to the system but which do
not have devices assigned to them. Therefore these rooms are "unconnected"
from the server.
59
Administrator User Guide
Understanding Device Status
Since devices are associated with rooms as a 1:1 relationship, click ROOMS from the
main menu to open the Room Management page and view capture devices and their
statuses.
By default, the Room Management page initially appears in "tiled" view. This allows for a
quick-glance status assessment of the rooms listed. Use the filter drop-down lists across
the top of the page to identify which rooms/devices to show specifically.
See Viewing Device and Room Status for information on viewing rooms/devices in "list"
view.
The room tiles on the page provide device status information as follows:

Preview Tiles - Indicates that the device is actively capturing at the moment.

CAPTURE WAITING TO START - Indicates that a scheduled capture is within 5
minutes of starting and the device is in a "preroll" state, preparing for capture.

DEVICE IDLE - A tile showing a green icon and DEVICE IDLE text indicates that
the device is ready, is communicating with ALP, and is available to capture.

DEVICE OFFLINE - This status can appear in either yellow or red, and indicates
that the device is not communicating with ALP for some reason. It may be as
simple as the device has been powered down for the night and has not
restarted yet, or the network cable has been unplugged.

o
A yellow tile indicates there are upcoming captures that will not occur until
the issue has been resolved.
o
A red tile indicates a captures are being missed because of the offline status.
o
If the device is supposed to be online, check that it is powered on and
connected to the network. Then try power cycling it to return it into an online
state.
DEVICE OUT OF SYNC - Indicates that the timestamp between the device and
the ALP server is out of sync.
o
You may need to power cycle the device to re-establish synchronization
between the device and the time server.
These are not the only statuses shown but they are the ones you are likely to see most
often. Generally speaking, the color coding indicates that:
60
Administrator User Guide



Green Tile: Device is connected and happy and ready to serve.
Yellow Tile: There may be a problem with the device. Upcoming captures will be
affected if not resolved.
Red Tile: There is an immediate problem with the device and captures are being
affected or missed.
61
Administrator User Guide
Echo360 SafeCapture HD Specifications
The Echo360 SafeCapture HD (SCHD) is a dedicated, all-in-one capture appliance,
capable of capturing either standard or high-definition video input, along with display
and audio.
The appliance is used to capture video, computer display, and audio inputs from
connected capture devices, synchronizing the media feeds, then sends them to the
Echo360 Active Learning Platform (ALP). Students and Instructors then access ALP to
view the resulting media.
General specifications






Dimensions: 431mm wide x 317mm deep x 44mm/1RU tall (without mounting
options).
Meets global standards for ROHS 6/6 compliance.
Multiple internal temperature sensors with temperature-dependent variable
speed forced-air cooling.
Removable, cleanable air filtration.
World-compatible direct AC connection. Input voltage: 90-240vAC 50/60Hz,
using an IEC320-C13 cable.
Power and heat: 62 watts (212 BTU/hr) max, 50 watts (171 BTU/hr) during capture.
62
Administrator User Guide
Agency certifications


UL 60065, 7th Edition, 2006-11-20
FCC CFR47 Parts 15:107/15:109
Appliance display resolutions
The attached spreadsheet (86kb) lists all of the available appliance display resolutions.
The abbreviations in the spreadsheet are as follows:




DMT: Display Monitor Timing lists standard display timings for various resolutions
and screen sizes.
GTF: Generalized Timing Formula is a video timings standard.
CVT: Coordinated Video Timings (CVT) is a replacement for GTF.
CVTRB: Video Timings-Reduced Blanking is a VESA standard which offers
reduced horizontal and vertical blanking for non-CRT based displays.
Deployment options



Mount in a standard 19" A/V rack.
Set on a tabletop or shelf.
Mount directly to a surface within a podium.
NOTE: The maximum allowable operating temperature of the SafeCapture HD device is
50°C/122°F. Be sure to install the device in a location where the temperature around
the unit does not exceed this limit. If operated in an environment where temperatures
exceed this limit, the unit may overheat and malfunction permanently.
Display input







Capture full-motion output from any VGA, DVI or HDMI-enabled device,
including document cameras, electronic whiteboards, and computers.
Full-motion encoding records applications, annotations, embedded video, and
animations.
Capture input resolutions from 640x480 to 1920x1080. See Appliance Display
Resolutions.
High performance encoding engine provides H.264-encoded output at 30fps at
any resolution and bitrates from 240 kbps to 3.2 Mbps.
All input aspect ratios supported, encoded to either Normal (4:3) or Wide
(16:9/16:10) output.
Digital or analog input via DVI-I connector, passively adaptable to VGA or HDMI
input.
Primary display input can alternatively be used as a secondary video input and
will thus support the same video characteristics shown below.
63
Administrator User Guide
Video input





Digital (HDMI, DVI) or Analog (composite) video input.
NTSC or PAL support.
Capture input resolutions from QCIF to Full D1 and to HD-1080p.
Provides H.264-encoded output with configurable frame rates from 1fps to 30fps,
and bit rates from 120kbps to 3.2Mbps.
Primary video input can alternatively be used as a secondary display input and
will thus support the same display characteristics listed under Display input
above.
Recommendation for Composite Sources: It is recommended to configure your
composite source to provide 4:3 input.
Audio input






Audio encoding in stereo, mixed-mono, or mono.
Audio capture in AAC, sampled at 22kHz or 44kHz, encoded at bit rates from
32kbps to 128kbps CBR.
Options for Pro-level (+4dBu/1.228Vrms/1.737Vpk) or Consumer-level (10dBv/0.316Vrms/0.447Vpk) signals.
Pro Line-level audio input with bare wire termination for direct wiring of stereo
Balanced (non-powered) or Unbalanced audio.
Consumer Line-level audio input with stereo RCA connector.
Digital audio via in-band HDMI or DVI sources supported.
64
Administrator User Guide
Unpack and Connect the SafeCapture HD
This page describes how to install the Echo360 SafeCapture HD (SCHD) into the location
where it will perform captures. After placing and connecting the SCHD, the next step
will be to configure the device to communicate with the Echo360 Active Learning
Platform (ALP).
Order of steps: You MAY want to review the information in Configuring Capture
Devices, and download a device file to the USB Drive included with the SCHD before
placing the device in the room. If you already have a configured device file on a
thumb drive, you can use that for all SCHD devices if appropriate.
IMPORTANT! Consider location carefully: The maximum allowable operating
temperature of the SafeCapture HD device is 50°C/122°F. Be sure to install the device in
a location where the unit is well ventilated, and the temperature around the unit does
not exceed this limit. If operated in an environment where temperatures exceed this
limit, the unit may overheat and malfunction permanently.
What's in the box
Unpack the SCHD and confirm you have all of the items listed below. There should be
five separate pieces, including two mounting brackets.
Item
Picture
SafeCapture
HD
Power Cord
USB Drive
Two
mounting
brackets
65
Administrator User Guide
Installing/Connecting the SCHD
When considering where to place the SCHD device, be advised of the following
recommendations/requirements:





Review the safety standards that apply to installation location. Observe these
standards to ensure proper device functionality and avoid possible injuries.
Choose a room that does not include devices protected by HDCP (Highbandwidth Digital Content Protection). The SafeCapture HD does not record
high-definition content that is protected by HDCP.
Ground the appliance properly.
Note the device's MAC address. It is located on the back of the SCHD.
Note also the room into which you are installing the device. You will use the MAC
address to assign the device to the Room in ALP.
To install/connect the SCHD
1. Connect the power cord to the SCHD and to a wall outlet (preferred).
2. Connect the SafeCapture HD to the network.
3. Connect the display devices (laptop, PC, document camera, etc.) to the
channel labeled Primary Display/Secondary Video.


Use DVI-I (Dual Link) Digital-Analog cable.
If you do not have this type of cable, use a VGA to DVI-I adapter that has
both a 4-pin analog link and a dual digital link. The adapter illustrated
below is the correct adapter. DVI adapter.
66
Administrator User Guide
4. If you are using RCA connectors, insert them. If you are using the audio bare wire
block, see the Audio Bare Wire Block Diagram for the SafeCapture HD.
5. Connect the video device to the channel labeled Primary Video/Secondary
Display.
6. Turn on the SafeCapture HD.
7. Continue with configuration of the SafeCapture HD.
67
Administrator User Guide
Safety Instructions and Regulations for the
SafeCapture HD
This page provides the safe use instructions and appliance safety regulations for the
SafeCapture HD device. Review this page carefully before using the SafeCapture HD
(SCHD).
Safety Symbols
Symbol
Description of Indicated Hazard
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instruction in the
literature accompanying the appliance.
Important Safety Instructions
Notification Symbol
Description of Hazard
This appliance has been designed and
manufactured to assure personal safety.
Improper use can result in electric shock
or fire hazard. The safeguards
incorporated in this appliance will
protect you if you observe the following
procedures for installation, use, and
servicing. This unit does not contain any
parts that can be repaired by the user.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
68
Administrator User Guide
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of
time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
15. If you see smoke coming from the appliance or if the appliance gives off an
unusual odor, immediately disconnect the power cord from the wall outlet.
Failing to disconnect the power risks fire. Make sure the smoke or odor dissipates.
Then contact Echo360 or your dealer for evaluation and repair.
16. If you are concerned about the safety or integrity of the appliance:
a. Disconnect the power cord from the wall outlet AND from the appliance.
b. Contact Echo360 or your dealer for evaluation and repair.
Notification Symbol
Description of Hazard
If any electrical issue is suspected or found, disconnect
the appliance from all power by unplugging the power
cord from the wall socket AND from the appliance.
Turning off the power switch does not completely
isolate the device from AC power.
69
Administrator User Guide
Rack Mount Installation
Be advised of the following when using a rack mount installation for the SCHD:





Elevated Operating Ambient Temperatures. If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment
may be greater than the room ambient. Make sure the rack environment is no
warmer than the maximum ambient temperature specified by Echo360. See
note below.
Reduced Air Flow. Make sure the rack environment has sufficient air flow.
Mechanical Loading. Mount the appliance evenly and securely.
Circuit Overloading. Do not overload the supply circuit. Overloading can
compromise overcurrent protection and supply wiring. Adhere to the ratings on
the equipment nameplates.
Reliable Grounding/Earthing. Reliable grounding of all appliances must be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips).
IMPORTANT: The maximum allowable operating temperature of the SafeCapture HD
device is 50°C/122°F. Be sure to install the device in a location where the temperature
around the unit does not exceed this limit. If operated in an environment where
temperatures exceed this limit, the unit may overheat and malfunction permanently.
Regulatory Compliance Information
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a non-residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
70
Administrator User Guide
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the appliance and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
--Consult Echo360, your dealer, or an experienced radio/TV technician for help.
To assure continued compliance, follow the provided installation instructions and use
only shielded interface cables when connecting to peripheral devices.
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause
undesired operation. See instructions if interference to radio or television reception is
suspected.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit
pas produire de brouillage et (2) l'utilisateur du dispositif doit étre prêt à accepter tout
brouillage est susceptible de compromettre le fonctionnement du dispositif.
Changes or modifications made to this equipment, not expressly approved by Echo360
or parties authorized by Echo360, could void the user's authority to operate the
equipment.
Radio and Television Interference
This equipment generates, uses, and can radiate radio-frequency energy. If it is not
installed and used in accordance with instructions provided by Echo360, it may cause
interference with radio and television reception.
This equipment has been tested and found to comply with the limits for a Class A digital
device in accordance with the specification in Part 15 of the FCC rules. These
specifications are designed to provide reasonable protection against such interference
in an installation. However, there is no guarantee that interference will not occur in a
particular installation.
You can determine whether this appliance is causing interference by unplugging the
device. If the interference stops, it was probably caused by the equipment.
If this equipment does cause interference to radio or television receptions, try one or
more of the following techniques:

Turn the radio or television antenna until the interference stops.
71
Administrator User Guide



Change the orientation of the appliance relative to the radio or television.
Move the appliance farther away from the radio or television.
Plug the appliance into an electrical outlet that is on a different circuit from the
radio or television.
If necessary, consult an experienced radio/television technician for additional
suggestions.
WARNING! Changes or modifications to this appliance that are not authorized by
Echo360, Inc. could void the EMC compliance and negate your authority to operate
the appliance.
This appliance has demonstrated electro-magnetic compliance (EMC) when using
shielded cables (including Ethernet cables) between system components to reduce the
possibility of causing interference to other electronic devices.
Disposal and Recycling
This equipment uses a long-life battery to maintain memory settings. The battery may
not need to be replaced during the life of the appliance.
If the battery does need to be replaced, please refer servicing to Echo360 or your
dealer.
Do not dispose of this appliance with normal household or light commercial waste.
Contact your local waste disposal agency for advice.
72
Administrator User Guide
Audio Bare Wire Block Diagram for the SafeCapture
HD
If you are using audio bare wire connections instead of RCA cables for audio transfer,
use the information and diagrams provided here to properly connect the SCHD device.
The diagram below shows the proper cabling for:



Balanced input - with 600 ohm input impedance
Balanced input - with high input impedance
Unbalanced input - with high input impedance
73
Administrator User Guide
SCHD Input and Device Settings
Every capture appliance has a default configuration applied to it, which can be edited
for each individual device as necessary.
To configure the SCHD device defaults
1. Log into ALP as an administrator.
2. Click the Settings icon in the upper right corner of the page (it looks like a gear).
3. Select Configurations from the settings menu.
4. From the left side of the Configurations page, click Device default configurations.
5. From the options across the top, select SCHD.
6. In the Audio section of the page use the input drop-down list to identify the type
of device input being used to capture audio. Your choices include RCA and
Balanced.
7. Use the audio level drop-down list to select the input level to use for audio
capture. You can select any number between -12db and 60db.
8. The Primary Display/Secondary Video and Secondary Display/Primary Video
sections of the configuration page are identical, and allow you to select which
device to use for display and video inputs based on connection type. Each
channel supports up to two connected devices, one of each of the following
types:


DVI-I
Composite
74
Administrator User Guide
9. Use the Primary Display/Secondary Video input sliders to identify the connected
device types that will be capturing the feed to this channel. This is the visual
input that will appear on the LEFT side, if there are multiple graphical inputs
selected.
10. Where DVI-I is enabled, select the DVI type and Aspect Ratio for the feed, as well
as whether this input device is capturing Video or Display.
11. Where Composite is enabled, select the Video Standard for the input device:
PAL or NTSC.
12. Repeat these steps for the connected devices capturing the Secondary
Display/Primary Video.
13. When finished, click Save, then click the Common Settings tab at the top of the
page, to complete device configuration for download to a USB drive.
75
Administrator User Guide
Understanding the LEDs on the SafeCapture HD
The front of the Echo360 SafeCapture HD has 10 LEDs, grouped in two banks of 5, as
shown in the photograph below. There is also an Echo360 logo light in the center,
between the two banks, that indicates recording status of the device.
As indicated in the picture, to identify each of the LED lights, we have numbered them
1 to 10, from left to right. Each light and its indications are described in more detail in
the section below.
Each LED can display different colors (blue, green, yellow, orange, red). Some also
blink. The colors and blinking indicate different states, as identified in the following
graphic.
This information is downloadable as an Excel spreadsheet for screenreader users if
necessary.
In the above table, some text is demarcated by asterisks (example: *>95%*). The
asterisks mean that the LED blinks.
The color of the text matches the LED blink color. For example, the CPU Load light
(LED3) blinks white when the CPU load is above 95 percent. This is shown in the table by
the white "*>95%*." text.
76
Administrator User Guide
Descriptions of the LEDs
Each of the LEDs on the front of the SafeCapture HD device is described below. The
LEDs are numbered 1 through 10, from left to right as you are looking at the front of the
device.
Power (LED1): Indicates the power state of the appliance. Depending on the model of
SafeCapture HD, this light can indicate the following:

In SafeCapture HD models with serial numbers containing PHB or later, this light is
connected to the power supply and indicates that there is power to the device
and the power switch is turned on. If the light is off, the device is not receiving
power and may have a blown fuse. See Troubleshoot the SafeCapture HD
Power Supply for more information on checking and replacing fuses.

In SafeCapture HD models with serial numbers PHA and earlier (for example,
PGH), the light is active only when the unit starts (boots up).
Mean Temp (LED2): Indicates the mean internal temperature of the appliance, based
on measurements from seven on-board sensors.
Action Required if LED2 blinks white!!
The Mean Temp indicator (LED2) blinks rapid-white if any internal sensor detects a
component over its rated temperature. Cool the appliance immediately:




Ensure that all the exhaust fans and intakes on either side of the appliance have
ample clearance.
Provide sufficient ventilation to enclosed spaces containing an appliance, such
as podia and equipment closets. Heat accumulates in enclosed spaces.
Use the provided rack-mounting hardware to mount the appliance in an
enclosure designed for professional-grade electronics.
Relocate the appliance to an open air environment if the enclosed space
cannot provide appropriate ventilation.
CPU Load (LED3): Indicates the total percentage load of the central processing unit
(CPU).
DSP Load (LED4): Indicates the combined total percentage load of the channel-1 and
channel-2 digital signal processors (DSPs). This light is not active. It will almost always be
blue.
Eth0 (LED5): Indicates the interface and link state of the appliance's Ethernet port.
Echo360 logo. The round Echo360 logo between the two LED sets shows capture worker
status. Off means the device is idle; Red means the device is recording; blinking
indicates the capture binaries (firmware) are restarting.
USB (LED6): Indicates the state, if any, of devices connected to the appliance's USB
port.
77
Administrator User Guide
ALP Com (LED7): Indicates the state of the appliance's communications connectivity
with the ALP server.
IP Config (LED8): Indicates the state of the appliance's IP configuration.
Channel 1 (LED9): Indicates the status and type of signal(s) present on input channel 1.
Channel 2 (LED10): Indicates the status and type of signal(s) present on input channel 2.
When more than one signal is present on Channel 1 or Channel 2, the indicators will
alternate between the colors representing those signals while the device is idle. While
the device is recording, only the recorded signal's color is lit.
78
Administrator User Guide
Troubleshooting the SafeCapture HD Power Supply
In some cases, the SafeCapture HD does not work after installation or stops working
after maintenance.
If none of the LED lights are illuminated (not even the green power LED1), the problem
usually relates to the power source or power supply. In most cases, the problem is a
loose, blown, or improperly installed fuse.
If you are having a power source problem, verify that the fuse is intact and is properly
installed.
Disconnect the Power to the SCHD!
Before beginning any work on the SafeCapture HD, turn the power switch off and
unplug the device. Simply turning the device off does not remove the device from the
AC power supply.
Remove and Inspect the Fuse Block
The fuse block for the SafeCapture HD is a red plastic block that resides to the left of the
power switch in the power switch assembly on the back of the device. Follow the below
steps to remove the fuse block and verify the fuse is installed correctly.
1. Open the cover to the fuse block using either your fingers or a flat-head
screwdriver. The picture below shows the fuse block being removed from the
power switch assembly.
2. As you remove the fuse block, note of the positions of the following items:

The fuse resides in the top of the fuse block, positioned in the fuse slot so
that it sits toward the inside (front) of the SCHD.
79
Administrator User Guide
The horizontal metal bars, shown on the left side of the fuse block in the
picture above, are on the side away from the power switch and power
cord connection.
3. Once the fuse block has been removed from the SafeCapture HD, check for
improper assembly of the fuse block. The picture below shows a fuse block with
the fuse installed correctly. Notice that:





The "inside" end of the fuse block (the end positioned closest to the front
of the SafeCapture HD), has flat metal prongs, similar to those on a power
cord. These prongs plug into the key for the fuse block inside the power
switch assembly.
The slot for the fuse may be longer than the fuse you are using. The fuse
block is designed to work with two different types of fuses, of different
lengths. The picture below shows the shorter fuse.
The fuse is placed in the slot so that one end of the fuse is located at the
pronged end of the fuse slot. This is the end of the fuse block inserted into
the SafeCapture HD first.
Underneath the "inside" or pronged end of the fuse slot is a metal
contact. This is not an electrical contact. It is a spring that provides tension
against the fuse from underneath.
80
Administrator User Guide
4. Inside the switch assembly (from which you removed the fuse block) there is an
electrically-active contact. When a properly configured fuse block is placed
inside the power switch assembly, the tension spring presses the fuse against it.
This helps ensure constant contact with the fuse.
5. Once you have finished inspecting the fuse and block, and ensuring the fuse is
intact and the block configuration is correct, re-insert the fuse block into the
power switch assembly.
If you still don't have power, you may have inserted the fuse block incorrectly. This will
not cause permanent damage to the SCHD, but you will not receive power until the
fuse and fuse block are installed properly.
Check for Improper Assembly
There are a number of easy-to-miss fuse block items that will cause the SCHD to not
receive power until they are fixed.
Fuse Not Properly Placed in Fuse Slot
The fuse slot is designed to accommodate two different size fuses. One is longer than
the other. If you have the shorter fuse, it may be installed at the wrong end of the fuse
slot. The fuse will snap in as you expect, but because the inside end of the fuse is not in
contact with the metal spring, it is not being pressed against the electrical contact
inside the power switch assembly. The picture below shows a fuse improperly installed
into the fuse slot.
As identified in the above picture, notice that:

The left end of the fuse is not located at the pronged end of the fuse block.
81
Administrator User Guide

The metal spring is visible. If it is visible, it will not press the fuse against the
electrical contact inside the power switch assembly.
If this is the problem, remove the fuse and re-insert it into the fuse block, placing one
end of the fuse at the pronged end of the fuse block.
Missing Metal Clip
If you flip over the fuse block to view the underside (the side opposite the fuse slot), you
should see a metal clip, as shown in the picture below.
The clip is required to complete the electrical circuit. While the clip is typically wellsecured to the fuse block, it is possible to accidentally knock it loose while handling the
fuse block. If this clip is missing, you will not get any power to the device, although the
device is not harmed.
Re-attach the clip to the fuse block. Place the clip at the pronged end of the underside
of the fuse block, with the open end facing away from the prongs, as shown in the
picture above. It should snap into place. This clip resides on the bottom of the fuse
block and cannot be clipped onto the top (fuse side) of the fuse block.
82
Administrator User Guide
Performing a Factory Reset on the SafeCapture HD
All new SafeCapture HD's manufactured after March 2015 allow you to perform a
factory reset, via the reset button located on the back of the device. Note that the
reset process can take up to 10 minutes. Ensure that the unit does not lose power or is
restarted during the reset process.
If your device was manufactured prior to March 2015, the factory reset capability must
be applied to the device through a device firmware update. In all likelihood, this has
already happened. However you can ask the following questions; if you answer "Yes" to
ANY of them, the device's firmware supports the pushbutton reset to factory settings :



Has the device been successfully connected to ALP?
For customers migrating to ALP from ESS, was the ESS running 5.4 Service Pack 5,
and did you update your firmware then?
Did you otherwise run a device_reset.tgz that had support of this feature?
To activate the reset, the reset button must be pressed while powering on the
device. Pushing the reset button by itself is not sufficient.
IMPORTANT!! As with all factory resets, any existing captures saved on the unit but not
uploaded to ALP will be lost as a part of the process.
To perform a push button SCHD factory reset
1. While the SafeCapture HD is powered off, press and hold the reset button. It is a
small black button, identified in the below figure, located to the left of the
power-assembly, on the back of the SCHD device.
2. While pressing the button, power on the SafeCapture HD. Continue holding the
button.
3. Release the button after 10 seconds.
83
Administrator User Guide
84
Administrator User Guide
Echo360 PRO Device Specifications
The Echo360 PRO is the newest (3rd) generation full-service capture device by Echo360.
It was placed into service in December 2015.
Deployment Options


Mount in a standard 19" A/V rack
Set on a tabletop or shelf
The allowable operating temperature of the Echo360 PRO device is between 0° –
50° C (32° – 122° F). Be sure to install the device in a location where the
temperature around the unit does not exceed this limit. If operated in an
environment where temperatures exceed this limit, the unit may overheat and
malfunction permanently.
Display





Capture full-motion output from any of the following types of device
connections, including document cameras, electronic whiteboards, and
computers
o Composite
o VGA
o HDMI
o 3G-SDI
Full-motion encoding records applications, annotations, embedded video, and
animations.
Capture input resolutions from 640×480 to 1920×1200.
High-performance encoding engine provides H.264 encoded output at 30fps at
all resolutions and bitrates from 240kbps to 3.2Mbps.
All input aspect ratios supported.
85
Administrator User Guide
Appliance Display Resolutions
You can download a spreadsheet (86 KB) with all of the specific resolutions.




DMT: Display Monitor Timing lists standard display timings for various resolutions
and screen sizes.
GTF: Generalized Timing Formula is a video timings standard.
CVT: Coordinated Video Timings (CVT) is a replacement for GTF.
CVTRB: Video Timings-Reduced Blanking is a VESA standard which offers
reduced horizontal and vertical blanking for non-CRT based displays.
Video



Fullscreen (4:3) standard definition input resolutions from QCIF to D1.
Widescreen (16:9) high definition input resolutions from 480p to HD-1080p.
Provides H.264-encoded output with configurable frame rates including
12.5/14.985fps or 25/29.97fps at bitrates from 120kbps to 3.2Mbps.
Audio





Audio encoding in stereo, mixed-mono or mono.
Audio capture in AAC, sampled at 22.05kHz or 44.1kHz, encoded at bitrates from
32kbps to 128kbps CBR.
Options for pro-level (+4dBu/1.228Vrms/1.737Vpk) or consumer-level (10dBv/0.316Vrms/0.447Vpk) signals.
Professional line-level audio input with bare wire termination for direct wiring of
stereo balanced (non-powered) or unbalanced audio.
Consumer line-level audio input with a stereo RCA connector.
NOTES about HDMI Audio
o
o
o
HDMI audio can only be utilized when also capturing HDMI video. For
example, if you have an HDMI input and a VGA input connected on
Channel 1, you could not use VGA for video and HDMI for audio.
HDMI audio is always mixed with the analog source. If you want to use HDMI
audio you must also use the balanced or unbalanced audio input. The
device can mix from one to three sources of analog
(balanced/unbalanced), HDMI 1 and HDMI 2.
We currently support two channel PCM encoded audio over HDMI, however,
high data rate encoded audio (like Dolby 5.1) is not supported.
86
Administrator User Guide
Package Options
These packaging options produce viewable media for students:




Podcast. MP3 audio
Vodcast. M4V audio and motion display
Audio Rich Media. Flash-based audio and display (browser)
EchoPlayer. Flash-based audio, video and display (browser)
Signal Processing and Encoding
Signal pre-processing includes decimation, automatic de-interlacing, and noise
reduction.
General








Dimensions: 431mm wide x 317mm deep x 44mm/1RU tall (without mounting
options)
Weight: ~11.8lbs / 5.4kgs
Internal temperature sensors with temperature-dependent, variable speed,
forced-air cooling
World-compatible direct AC connection; input voltage: 90-240vAC 50/60Hz,
using an IEC320-C13 cable
Operating environment: 0°-50°C (32°-122°F) ambient temperature
Operating humidity: 25% to 80%, non-condensing
Power requirements: 100vAC to 240vAC, 50/60Hz
Power consumption & heat: 62 watts (212 BTU/hr) max, 50 watts (171 BTU/hr)
during capture
Agency Certifications


UL 60065, 7th Edition, 2006-11-20
FCC CFR47 Parts 15:107/15:109
87
Administrator User Guide
Installing the Mounting Brackets on the Echo360 PRO
The mounting brackets may be used to mount the Echo360 PRO (the capture
appliance) in several configurations. This document describes how to install the
mounting brackets that let you mount the capture appliance in a rack.
The allowable operating temperature of the Echo360 PRO device is between 0° – 50° C
(32° – 122° F). Be sure to install the device in a location where the temperature around
the unit does not exceed this limit. If operated in an environment where temperatures
exceed this limit, the unit may overheat and malfunction permanently.
Rack mount configuration
To mount the capture appliance in an A/V rack, you must first install the mounting
brackets.
What you'll need:



A #1 Phillips screwdriver.
Proper rack clips and screws for your A/V rack. Please contact your A/V rack
supplier. Echo360 does not supply these items.
The rack mount kit that came in the packing box with the new capture
appliance. It contains two mounting brackets and eight 4-40 X 3/8” Phillips flathead machine screws.
The rack mount kit only comes with newly purchased devices. If you receive a
replacement device through an RMA, please reuse your mounts rather than
returning them with the defective unit. Additional rack mounting kits can be
requested.
Bracket installation for rack mounting
1. Place the capture appliance on a flat work surface with the foot assemblies
facing upward.
2. Remove the four plastic feet from the bottom of the unit. Each foot is secured
with one screw. You will not need the screws and feet for this mounting
88
Administrator User Guide
configuration but may wish to save them.
3. Flip the device over and place on a flat surface facing front or rear depending
on desired mounting configuration. Remove the four screws on each side of the
enclosure (eight screws total). You will not need the screws for this mounting
configuration but may wish to save them.
4. Find the eight long screws provided in the rack mount kit. Use these screws to
attach one mounting bracket to each side.
89
Administrator User Guide
5. Compare the finished capture appliance with the following two figure(s). Notice
that the mounting brackets are parallel with the front/ rear panel.
6. Install the capture appliance in the A/V rack.
90
Administrator User Guide
Install the Echo360 PRO
This page describes how to set up and install the Echo360 PRO (PRO). After you
complete this procedure, continue with configuring the Echo360 PRO.
The allowable operating temperature of the Echo360 PRO device is between 0° – 50° C
(32° – 122° F). Be sure to install the device in a location where the temperature around
the unit does not exceed this limit. If operated in an environment where temperatures
exceed this limit, the unit may overheat and malfunction permanently.
Installation
1. Unpack the box and confirm you have all of the items listed below. There should
be three separate pieces, including two mounting brackets.

Echo360 PRO

Power cord

Two mounting brackets
The mounting brackets only come with newly purchased devices. If you
receive a replacement device through an RMA, please reuse your mounts
rather than returning them with the defective unit. Additional rack
mounting kits can be requested.
2. Place the PRO where you want it.

Observe the safety standards that apply to the installation location.
91
Administrator User Guide
Choose a room that does not include devices protected by HDCP (Highbandwidth Digital Content Protection) protected devices. The PRO does
not record high definition content that is protected by HDCP.
 If required, follow the instructions in Install Mounting Brackets on PRO.
 Be sure to ground the appliance properly. See Ground the Capture
Appliance below.
3. On the back of the PRO, find the label with the device's MAC address. Write
down the MAC address. You will need this information to assign the device to a
room.

4. Connect the power cord to the PRO and a wall outlet.
5. Connect the PRO to the network.
6. If you are using RCA connectors, insert them. If you are using the audio bare wire
block, see the Audio Bare Wire Block Diagram for Echo360 PRO.
7. Connect the video and/or display devices to either of the input channels
(labeled Channel 1 and Channel 2). For supported inputs, please see our
product specifications.
8. Turn on the PRO.
9. Continue with the procedures in Configure the Echo360 PRO.
Ground the Capture Appliance
If you do not properly ground the capture appliance, you may introduce electrical
issues. Do the following:


Be sure to use the 3-prong power cable provided to plug the capture appliance
into a grounded (3-prong) socket. Using a 3-prong cable ensures that your
appliance is properly grounded.
If you must use a 2-prong socket, then you must also ground the appliance.
Attach one end of a ground wire to any of the chassis screws on the back of the
appliance. Attach the other end to a natural earth ground.
92
Administrator User Guide
Configure the Echo360 PRO
This process assumes you have already installed the Echo360 PRO. Configuring the PRO
for use with ALP consists of the procedures identified on this page, which include:
Configure and download default PRO device settings
The first thing you MUST do to configure any capture appliance is upload a device
configuration file to the device. Among other things, this device configuration file sets
up communication with the ALP server.
The device configuration file (device.xml) is uploaded to the device from a USB thumb
drive. The file is loaded onto the thumb drive through the Default Device Configuration
page, located in the Settings > Configuration page in ALP.
Besides setting the default input devices for each recording channel, the configuration
page allows you to set defaults for One-touch ad hoc recordings and the
Administration menu availability. These are described in more detail below.
You can use the same configuration file to configure all of your PRO capture
appliances if appropriate. Individual device configuration changes can be made via
the ROOMS page.
Enable/Disable Administration menu access
The Device Configuration page provides administrators with the option to show or hide
the Administration menu on the front panel display of the PRO. If the menu is disabled,
the Administration menu is not available from the Front Panel of the PRO appliance.
See the Administration Menu section Menu Options for the Echo360 PRO topic for
details on this menu.
Set the One-Touch recording profile
The PRO device simplifies ad hoc recordings by allowing instructors to simply press the
Record button on the front of the device to begin an ad hoc capture. The ad hoc
capture is generated using the Input sources and Quality configured for the One-Touch
Recording Profile of the device configuration page.
93
Administrator User Guide
Users can review these settings and change them if needed using the menus available
through the front panel display. Note that user changes apply ONLY to that particular
capture; after completion, the configured one-touch ad hoc recording settings are reestablished.
To configure and download device default settings
1. Log in to ALP as an administrator.
2. Insert a FAT 32 formatted USB thumb drive into the computer. If possible, use the
thumb drive that came packaged with your PRO device.
3. Open the Settings menu and select Configurations.
4. Select Default Device Configurations.
5. Select the PRO device configuration page, and set the default device inputs,
administration menu, and one-touch profile settings for your PRO device.
6. Select the Common Settings page and update/change those settings as
needed.
7. Verify that the settings on both page are correct and click SAVE.
8. Click DOWNLOAD.
9. Navigate to the thumb drive and save the device.xml file to the root location of
the drive (not in a folder; the device will not be able to find the file if it resides in
a folder on the drive).
10. Once finished, safely eject then remove the USB drive from the computer.
Do Not Modify the Downloaded File! The configuration file you download from ALP is a
digitally signed file. The PRO will NOT accept files that do not bear this digital signature.
Do not modify this file. If you need to make changes, repeat the above steps and redownload a new file.
Apply the configuration file to the PRO device
Perform the below steps for each PRO appliance that must be configured with the
downloaded device configuration file from the above section.
Wait! Do not insert the USB drive until instructed.
94
Administrator User Guide
To apply the configuration file to the PRO device
1. On the back of the PRO, find the label with the device’s MAC address.
Make a note of the MAC address for the device; you will need it to log into the
PRO and monitor inputs, as well as to assign the device to the room.
A typical MAC address is 00-50-c2-7b-1b-98.
 The MAC label is also on the bottom of the Echo360 PRO.
2. Turn on the PRO.

3. Make sure the Echo360 PRO has been on for at least five minutes or that the
Status Screen is displayed.
4. Insert the USB drive into the front of the PRO.
5. A message will then appear, prompting you to load the device XML onto the
device. Select OK to load the configuration file.
6. Navigate through the Administration Menu to the Manage Network Menu to
check that the device has received a valid IP address.
Make a note of the IP address for the device; you may need it to log into the
device and check inputs.
Once the device has been configured, it begins communicating with ALP.
Since the device-to-ALP communication has been established, the device can be reset
if it is ever needed, or if you are asked by support to reset the device. Device reset can
be done manually or through the Administration Menu on the Front Panel display.
Register the PRO device and check the installation and inputs
There are actually two ways to check the PRO installation; assign the device to a room,
then open the device Web UI to log into the device, OR simply log into the device Web
UI before assigning it to a room.
If you log into the device Web UI first, and the installation is working properly, you can
assign it to a room after that. However to do this, you must have the IP address assigned
to the device.
If you do not have the IP address, assign the device to a Room first.
To log into the device Web UI for the PRO and check inputs
1. Be sure you have the IP address for the device.
2. Open a browser and enter the following into the URL field: https://<IP
address>:8443
For example: https://10.3.10.18:8443 where 10.3.10.18 is the IP address for the
device.
3. When prompted, enter a username and password. You can use your ALP login or
the generic administrator login configured for the device.
You should see the device interface as shown in the below figure.
95
Administrator User Guide
4. Click the Monitor tab.
5. Click Start Monitoring.
After a few minutes you should see the feeds for the inputs you established in the
uploaded device configuration.
6. When finished, click Logout from the top right of the device interface.
To assign the device to a room then login to check inputs
1. Be sure you have the MAC address for the device.
2. Log into ALP and navigate to the ROOMS page.
3. Find the room you want to add the device to. Use the filtering lists at the top of
the screen to narrow which rooms are shown.
4. Click ADD DEVICE TO ROOM.
5. From the Device list, select the MAC address of the device you want to add to
the room.
6. Click SAVE.
7. Click the log in icon located in the bottom left corner of the room tile.
8. When prompted, enter a username and password. You can use your ALP login or
the generic administrator login configured for the device.
You should see the device interface as shown in the below figure.
9. Click the Monitor tab.
10. Click Start Monitoring.
After a few minutes you should see the feeds for the inputs you established in the
uploaded device configuration.
11. When finished, click Logout from the top right of the device interface.
If the inputs are not working properly, return to the device and check the connections
and input devices themselves. Then repeat the steps for logging into the device and
monitoring inputs.
You may also need to alter the device configuration for the ROOM, to change the
default configuration settings initially uploaded to the device.
Next Steps
The PRO is ready to capture presentations. The next steps you'll want to take include:
1. If you have not already, assign the capture appliance to a room.
2. If necessary, alter the device configuration for the ROOM from the default
configuration initially uploaded to the device.
3. Add or edit schedules to use the room with the new device.
96
Administrator User Guide
Configuring Echo360 PRO Input and Device Settings
Every capture appliance has a default configuration applied to it, which can be edited
for each individual device as necessary.
To configure the PRO device defaults
1. Log into ALP as an administrator.
2. Click the Settings icon in the upper right corner of the page (it looks like a gear).
3. Select Configurations from the settings menu.
4. From the left side of the Configurations page, click Device default configurations.
5. From the options across the top, select ECHO360 PRO.
6. In the Audio section of the page use the input drop-down list to identify the type
of device input being used to capture audio. Your choices include RCA,
Balanced, and Mute.
The Mute option is provided if you are planning to capture audio through an
HDMI device input, and ONLY want the HDMI audio feed. See note below on
multiple audio feeds.
7. Use the audio level drop-down list to select the input level to use for audio
capture. You can select any number between 11db and -11db.
8. The Channel 1 and Channel 2 sections of the configuration page are identical,
and allow you to select which device to use for display and video based on
connection type. Each channel supports up to four connected devices, one of
each of the following types:




HDMI
VGA
Composite
3G-SDI
97
Administrator User Guide
9. Use the Channel 1 Display input drop-down list to identify the connected device
type that will be capturing the display feed.
10. Use the Channel 1 Video input type drop-down list to identify the connected
device type that will be capturing the video feed.
11. Repeat these steps for the connected devices capturing through Channel 2.
12. As applicable, select the Aspect ratio for each selected input, or the Video
Standard (NTSC/PAL) to use (for a Composite connection).
13. If you are using an HDMI-connected input device, enable or disable the Capture
HDMI audio slider for each selected HDMI device.
Multiple Audio feeds? Since HDMI inputs also allow for audio capture, the PRO
appliance can capture up to three different audio feeds (one HDMI for each
channel plus the Audio channel). When the capture is processed, all enabled
audio feeds are merged and synced to generate the audio for the capture
playback. You don't need to use anything except the Audio channel, but you
can, either in addition to or instead of the Audio channel input.
14. Enable or disable the access to the Administration menu on the front panel of
the PRO appliance.
15. Select the Input sources and Quality settings for the One-Touch recording profile.
The inputs/quality configured here are used as the capture profile for all ad hoc
98
Administrator User Guide
recordings initiated using only the Record button on the front of the appliance.
Users can review these settings and change them if needed using the menus
available through the front panel display.
See also the Echo360 PRO FAQs and How To's for additional information on the
One-touch profile.
16. When finished, click Save, then click the Common Settings tab at the top of the
page, to complete device configuration for download to a USB drive.
99
Administrator User Guide
Audio Bare Wire Block Diagram for Echo360 PRO
The Echo360 PRO appliance allows you to use either RCA inputs for the Audio channel,
or bare wire audio connections. If you are using bare wire audio, refer to the diagram
below for proper configuration. The diagram shows the proper cabling for:



Balanced input - with 600-ohm input impedance
Balanced input - with high input impedance
Unbalanced input - with high input impedance
100
Administrator User Guide
About the Front Panel of the Echo360 PRO
The front of the Echo360 PRO has a display panel as well as touch button controls,
audio indicator lights (VU meter), a USB drive and a headphone jack (intended for
monitoring audio levels and will always have the currently recording audio on it).
The Buttons
The touch buttons on the front of the PRO device allow you to control recordings, as
well as provide navigation controls for the front panel menus described later on this
page.
Button
Up / Down
Description
Can be used to move up or down through the menu options
as well as to move forward or backward through a
configurable field.
Also used to scroll through alphanumeric input options (press
Enter to select the letter or number to alter, then up and down
buttons to scroll through selection options, then press Enter
again to confirm your selection).
Enter
Used for selection and confirmation. Use the Up/Down buttons
to navigate to a selection, then press Enter to select it.
Back
Used to return to the previous screen/menu.
101
Administrator User Guide
Button
Description
Home
Press at any time to return to the Home Menu.
Used for capture control.
When the Record button is pressed to start an ad hoc
capture, the PRO uses the inputs and quality selected for the
One-Touch Profile in the Device configuration page in ALP.
The recording will continue for two hours, or until the stop
button is pushed, or until five minutes before the next
scheduled recording is slated to begin.
Record/Pause
For more information, see One-Touch Product Group
configuration and "What is the One-Touch Profile" in our FAQs
topic.
LED Behavior
This button is backlit by an LED light that indicates the current
recording state:
Solid White = Idle, Not recording
 Solid Red = Recording
 Flashing Red/Off = Paused
 Flashing Red/White = Prerolling/Initializing recording.
Used for capture control.

Push the Stop button when you are finished with the class or
other session you wanted to record.
Stop
LED Behavior
This button is backlit by an LED that indicates the current
recording state (in conjunction with the Record/Pause button
described above):



Solid White = Idle, Not recording
Solid Blue = Recording, Paused, or in preroll/initializing
recording (see Record button for state indicator)
Flashing Blue/Off = Stopping and finalizing recording.
102
Administrator User Guide
The Status Screen
The Status Screen appears by default when the device is woken from a sleep state.
Under most conditions, when the device is not in use (not currently recording, paused,
or actively publishing), the display is off. As soon as a user presses any button on the
front panel, the display wakes and the Status Screen appears.
The Status Screen displays the following information:
#
Section
Description
1
Date and time
The current local time of the device, in HH:MM:SS
AM/PM (i.e. 10:00:40 AM)
103
Administrator User Guide
#
Section
Description
IDLE - Default state of the device when no capture task or
publishing task is occurring. When the device is in this state,
any action can be performed.
RECORDING - Device is currently recording. Below this state
is a timer with information as follows:
For Ad Hoc Captures, indicates the "time remaining"
based on a default ad hoc capture length of 2 hours.
 For Scheduled Captures:
o Displays the "Time Remaining", which counts the
timer down from the length of the scheduled
capture.
o Displays an option to Extend capture by 5-minute
increments (up to 1 hour). This requires
confirmation by the user.
PAUSED - The recording is currently paused.

2
Recording state
STOPPING - Device is stopping the recording. Below this state
is a "time remaining" indicator that counts down while the
device is finalizing the capture.
PRE-ROLLING - Indicates that the device is preparing to start
recording. The status is shown as follows:
For Ad Hoc Captures: Shown for a brief period while
the device communicates with ALP prior to the start
of the capture.
 For Scheduled Captures: Shown for 5 minutes prior to
the start of the capture. During this time, the user
could select to start the capture early. This requires
confirmation by the user.
INITIALIZING - This state appears while a Device
Configuration file is being applied to the device. This status
also appears briefly after initiating an ad hoc capture but
before the pre-rolling status.

104
Administrator User Guide
#
Section
Description
Recording status - Shows one of the following icons to
indicate the current recording.

Paused/Pre-Rolling:

Recording:
Idle/Stopping:
ALP connectivity - Indicates whether or not the device is
currently connected to ALP.


Connected
Disconnected
The headphone icon appears when the headphone jack is

3
Status icons
in use.
The recovery icon appears when the device is in recovery
mode.
For more information, see the FAQs topic.
An animated arrow appears while the device is uploading a
capture.
Device message codes E1 through E12 may also appear
with the status icons.
See Device Messages section below for additional
information.
Provides access to any pertinent actions that can be taken
by a user depending on the current recording state. For
example:
4

If the device is currently performing a scheduled
recording, this section will show Extend capture as
the action.
User presses Enter then confirms to extend the
capture by 5 minutes.

If the device is in pre-rolling state for a scheduled
capture, this section will show Start Early as an
action.User presses Enter then confirms to start the
capture early.
Capture
actions and info
When IDLE, this identifies the next scheduled capture (if
applicable).
5
Channel 1
input/
connection
What device connection the Channel 1 input is currently
configured to capture.
If there is no active recording, this will read None.
105
Administrator User Guide
#
Section
Description
6
Audio input/
connection
What input the Audio input is currently configured to use.
7
Channel 2
input/
connection
What input the Channel 2 input is currently configured to
use.
If there is no active recording, this will read None.
If there is no active recording, this will read None.
Device Messages
The PRO will provide error-type messages in specific situations. The message text
identified in the table below appears in lieu of a Recording Status in the status screen
(as described for section 2 of the front panel above).
The message number (E1 through E12) appears in the status icons section (section 3
above) of the status screen. If the need arises to contact Technical Support, please
provide the message code number when opening a support ticket.
Message
displayed
What to do?
Wait at least 5 minutes, to give the device time to recover. If
this message is still displayed after that time, power cycle the
device (turn it off, wait 5 minutes, then turn it back on).
Oops! Something's
wrong. Hold on
while I fix it.
If the power cycle fails, try a device reset. Access the
Administration menu and select Factory reset device.
IMPORTANT! A device reset erases all content on the device.
You may want to attempt to recover the data on the PRO's
internal drive prior to a reset.
If after these actions the device is still not functioning properly,
please contact Technical Support.
Oops! Something's
wrong. I need
help. Please
perform a factory
reset.
Perform a Factory reset (through the Administration menu).
This disk appears
to be empty. Hold
on while I set it up.
Even though this is an Error code, it's not necessarily an error
message. It is perfectly normal to see this message while
setting up the device.
Oops! Something's
wrong. My disk is
missing. Contact
Echo360 support.
You can try to power cycle the device, but it's likely this
message will result in requesting a replacement device if still
under warranty through an RMA (Return Merchandise
Authorization) . Please contact Technical Support.
Yes, the device could reset itself, but a device reset
automatically erases all content currently on the device.
Requesting you manually reset the device allows you to try to
recover any data on the PRO's internal drive prior to the reset.
106
Administrator User Guide
Message
displayed
Oops! Something's
wrong.
What to do?
If this is the only message shown, there is nothing you or the
device can do without technical assistance.
Run and save the built-in diagnostic report (through the
Administration menu) and send that information to Technical
Support in order to open a support ticket.
"Hold on while I fix it." If you are upgrading a device and a message appears on startup that includes, "Hold on while I fix it", the device may revert to a previous disk image. If
there is no previous disk image, the device will reboot in recovery mode.
107
Administrator User Guide
Menus and Options for the Echo360 PRO
The front panel display on the PRO device provides access to a series of device menus,
allowing you to interact directly with the device as needed.
Each of the menus is described below, along with the options provided for each.
The information below assumes the PRO device has already been installed and
configured (a device configuration file uploaded to the device).
Home Menu
Users can press the Home button on the front of the device to open the Home menu on
the PRO. The Home menu is the main access point for all other device menus. Use the
up and down buttons to highlight any of the HOME menu options, then press Enter to
open that sub-menu.
Users can always navigate back to the Home Menu by either backing out of the
currently selected menu or using the Home button.
Recording Menu
The Recording Menu provides information regarding the capture profile and capture
sources. Use the up and down arrow buttons on the device to scroll through the menu.
All Recording menu options are selectable and editable. Select a sub-menu option and
press Enter to edit the current setting/selection.
108
Administrator User Guide
Sub-menu selection
Description and Options
Defines the capture inputs for ad hoc captures (also called
a "capture profile"). Allows a user to select what inputs to
include in the ad hoc capture.
Profile
Selectable/editable
The options returned include the default profiles already
configured for the device (audio, audio/video,
audio/display, etc.). The existing device configuration
determines which input devices are used for the capture.
If a user selects one of the default capture profiles,
the corresponding inputs are automatically selected,
and displayed in the other Recording menu fields
(described below).
 If a user decides to manually change any of the
defined inputs, this profile changes to Custom.
Defines what device(s) will be used to capture audio.
Selections available depend on what kinds of devices are
connected to the PRO. Options can include:







Audio
Selectable/editable
Balanced Input
Unbalanced Input
HDMI (Channel 1)
HDMI (Channel 2)
3G-SDI (Channel 1)
3G-SDI (Channel 2)
NOTES about HDMI Audio



HDMI audio can only be utilized when also capturing
HDMI video. For example, if you have an HDMI input
and a VGA input connected on Channel 1, you
could not use VGA for video and HDMI for audio.
HDMI audio is always mixed with the analog source. If
you want to use HDMI audio you must also use the
balanced or unbalanced audio input. The device
can mix from one to three sources of analog
(balanced/unbalanced), HDMI 1 and HDMI 2.
We currently support two channel PCM encoded
audio over HDMI, however, high data rate encoded
audio (like Dolby 5.1) is not supported.
109
Administrator User Guide
Sub-menu selection
Description and Options
Defines the output volume level for the ad hoc capture.
Options include:
Volume
Channel 1 Input
Mute
 Low
 Medium
 High
Allows user to select which connected input device will be
used to record through Channel 1. Each option is shown
with "Connected" or "Not Connected" to indicate which
ports have a device plugged into them. Options may
include:

3G-SDI
 HDMI
 Composite
 VGA
User can select the quality output for the channel.

Channel 1 Quality
Channel 2 Input
Options include High (HD) or Low (SD).
Allows user to select which connected input device will be
used to record through Channel 2. Each option is shown
with "Connected" or "Not Connected" to indicate which
ports have a device plugged into them. Options may
include:
3G-SDI
 HDMI
 Composite
 VGA
User can select the quality output for the channel.

Channel 2 Quality
Options include High (HD) or Low (SD).
Allows user to select to record the capture to a USB flash
drive or other USB connected storage device (in addition to
recording to the PRO's internal SSD drive).
Options include Yes or No.
Copy media to USB
If No is selected, media is recorded to the SSD only.
This is the default.
 If Yes is selected, media is recorded to the SSD, and
then copied to the USB storage drive as a playable
.MP4 container.
For more information, please see "Save a capture to USB" in
the Echo360 PRO FAQs and How To's topic.

110
Administrator User Guide
Inputs Menu
The Inputs Menu allows a user to see which of the channel ports (Channels 1 and 2)
have valid input devices connected to them.
The Inputs menu information is read-only (not editable).
For each Channel, the Inputs menu shows following information about each
connected device, based on connection type. If the port is not used, the field is blank.




HDMI: capture resolution, FPS (frames per second), and whether or not Audio is
also captured via this device.
SDI: capture resolution and FPS
VGA: capture resolution and FPS
Comp (composite): NTSC or PAL, capture resolution, and FPS
Network Menu
The Network menu provides network connection and settings information for the PRO.
Use the up and down arrow buttons on the device to scroll through the menu.
The Network menu information is read-only (not editable).
111
Administrator User Guide
Field
Description
Whether the device is connected via DHCP IP address or Static IP
address.
IP Mode
This setting can also be configured on individual devices through
ALP. Open the ROOMS page and click the chevron for the room
containing the PRO device. Select Configure, then scroll down to
Network Settings.
IP (address)
The IP address of the appliance (if connected to an Ethernet
network).
MAC
(address)
MAC address (Serial #) of the appliance.
Subnet
mask
Subnet mask of the appliance (if connected to Ethernet network).
Default
gateway
Default router IP address (if connected to Ethernet network).
Primary DNS
Displays the address of your Primary DNS.
Secondary
DNS
Displays the address of your Secondary DNS.
Ethernet link
Displays whether the device has a valid Ethernet connection.
Displays Yes or No.
Ethernet
speed
Displays the current speed of the Ethernet connection.
Ethernet
duplex
Displays the current Ethernet mode. Displays Full or Half.
NTP server
Displays the address of the time server you are syncing with.
NTP status
Displays whether or not the device is in sync with the NTP Server.
Highlight and press ENTER to see details of the time server status.
Proxy server
Displays the address of your Proxy Server (if applicable)
Echo360
server
Displays whether the device is connected to an Echo360 Server.
Displays Connected or Disconnected
Status Menu
The Status Menu provides information on the status of the appliance itself.
The Network menu information is read-only (not editable).
112
Administrator User Guide
Field
Description
Firmware
Provides information on the device including firmware version
number and OS version.
Uptime
Provides information on device uptime (since the last reboot).
Device time
Lists device time in Local Time
Device
date
Lists device date in MM/DD/YYYY (US) or DD/MM/YYYY (UK) format.
Scheduled
recordings
Lists upcoming scheduled recordings. The information shown
includes the date of recording in MM/DD/YYYY (US) or DD/MM/YYYY
(UK) and title given for the scheduled recording.
Highlight and press ENTER to see details.
Resources
Provides device resource information, including Disk free space, Disk
life, CPU and memory utilization, CPU and Board temperature
readings, and other device-health information.
Highlight and press ENTER to see resources details.
Administration Menu
The Administration Menu provides access to controls for the administration of the
device.
All Administration menu options are selectable and editable. Select a sub-menu option
and press Enter to edit the current setting.
Administration Menu can be disabled: The Device Configuration page provides an
option to disable access to the Administration Menu via the device's front panel. If this
access is disabled, you will see the Administration option in the Home menu, but you will
not be able to access any of the sub-menu selections.
113
Administrator User Guide
Sub-menu
selection
Load device
XML
Manage
network
Save
diagnostics
report
Description and Options
Instructs the device to read the device.xml file via the USB port.
Provides real-time status on the loading of the file.
Options include OK and Cancel.
Allows the user to enter or configure the device information
provided through the Network menu.
See Manage Network below for details.
Initiates a download of the device log to a connected USB-drive.
Options include OK and Cancel.
Allows the user to select one of the audio inputs to listen to (via
the headphone jack) as well as select the monitoring volume.
Monitor audio
Options include Select inputs (from which you can select the
audio input to monitor) and Adjust the balanced/unbalanced
volume. Push the Back button to cancel/exit.
Ping
Allows the user to ping the localhost, the gateway, or a custom IP
address.
NS Lookup
Allows the user to run an NS lookup on a domain name or IP
address mapping, or any other specific DNS record.
Traceroute
Allows the user to run a traceroute command on a domain or IP
address.
Recover data
Provides the ability to bulk recover all captures from the Pro's
internal drive (SSD) to a USB-connected storage device (flash
drive or mass storage device).
For additional information, see Recover captures from SSD in the
Echo360 PRO FAQs and How To's topic.
Restart device
Factory reset
device
Initiates a restart (soft reset) of the device. Options include OK
and Cancel.
Initiates a hard reset of the device. Hard resets include both a
restarting of the device, as well as the ability to delete all device
settings and restore the device to its factory (out-of-the-box)
state. Options include:



Save Settings
Delete Settings
Cancel
114
Administrator User Guide
Manage Network
The Manage Network Menu (located within the Administration menu options) allows an
administrator or technician to configure the device network settings.
All Recording menu options are selectable and editable. Select a sub-menu option and
press Enter to edit the current setting.
Field
Description
IP Mode
Configure whether the device is connected via DHCP IP address or
Static IP address.
IP (address)
Identify or change the IP address of the appliance (if connected to
an Ethernet network).
Allows user to select/enter numeric input, then Save or Cancel.
Subnet
mask
Default
gateway
Primary DNS
Secondary
DNS
Renew
DHCP
Identify or change the subnet mask of the appliance (if connected
to Ethernet network).
Allows user to select/enter numeric input, then Save or Cancel.
Identify or change the default router IP address (if connected to
Ethernet network).
Allows user to select/enter numeric input, then Save or Cancel.
Identify or change the address of your Primary DNS.
Allows user to select/enter numeric input, then Save or Cancel.
Identify or change the address of your Secondary DNS.
Allows user to select/enter numeric input, then Save or Cancel.
Allows the user to renew the DHCP IP address (if applicable).
115
Administrator User Guide
Echo360 PRO FAQs and How To's
This topic addresses some of the more common tasks and questions surrounding the
Echo360 PRO appliance.
How-to...
Configure Channel inputs
1. Navigate to the Inputs Menu to see what inputs are currently connected and
available for use.
2. Return to the Home menu, then open the Recording menu.
3. Highlight Audio input and press Enter, then select the preferred option.
4. Return to the Recording Menu (press the Back button if needed).
5. Highlight Channel 1 input and press Enter, then select the preferred option.
6. Return to the Recording Menu (press the Back button if needed).
7. Highlight Channel 2 input and press Enter, then select the preferred option.
8. The selections you made should now appear across the bottom of the Status
Screen (numbered 5, 6, 7 in the below figure).
116
Administrator User Guide
Start an ad hoc recording
Press Record. Then press Stop when you're done. That's it!
Be sure to press Stop when you're finished though; ad hoc recordings will run for 2 hours
unless you stop it (or until the next scheduled recording is slated to begin).
The PRO device is already configured with a "One-Touch recording profile." If you trust
this profile to capture the inputs you want, you don't have to do any more than that.
However, if you want to check or adjust the inputs that are being used:
1. Navigate to the Recording menu and check the configured inputs (audio,
channel 1, channel 2).
2. To make changes, see the above instructions to configure a temporary custom
profile for the recording.
3. When ready, press the Record button.
4. When finished push Stop.
Ping the device
1. Navigate to the Administration Menu (if available).
2. Navigate down to Ping and press Enter.
3. Select the applicable Ping option, then press Enter.
4. If you select Ping custom address, enter the IP address that you'd like to ping,
then press Enter.
The device will then display your Ping results.
117
Administrator User Guide
Save a Diagnostics Report
1. Navigate to the Administration Menu (if available).
2. Press the down button to Save Diagnostics Report and press Enter.
3. Insert a USB drive into the device, then select OK.
Save a capture to USB-storage
The PRO allows for the ability to save the ad hoc capture to both a USB-connected
device as well as to the internal SSD drive of the PRO.
To configure the dual-location save feature
1. Before starting the ad-hoc capture, navigate to the Recording menu.
2. Navigate to the Copy media to USB option, and press Enter.
3. Select Yes. This allows the next capture made by the device to be saved to the
connected USB media.
This option will return to the default of No after the capture has completed. See
also the Additional Notes listed below.
4. After the capture has completed, if one is not already present, the device will
display the options, Please Insert USB drive and Press Home to Cancel.
As indicated, pressing the Home button on the device cancels the save-to-USB
action.
5. Once the device has detected a USB drive, it will display (in this order):



Preparing
Saving. Do not remove USB drive
Finished. Please remove the USB drive.
Additional Notes:



If no USB drive is inserted, the device will time out after 30 seconds and you will
lose the ability to copy your capture to USB. We recommend that you insert the
USB drive prior to the start of the capture.
If there is not enough space on the USB drive, the device will display, Not enough
space on USB drive. Please insert a drive with at least <size of your capture> free.
You are also given the option to Press Home to Cancel.
Occasionally, depending on the formatting of your USB drive, the device will
display, File size limited by USB drive's file system. Please insert a drive with at
least <size of your capture> free. This will happen most commonly when trying to
save a high quality, lengthy capture to a FAT-32 formatted USB drive. This format
has a 4GB file size limit. In this scenario, use an NTFS-formatted USB drive, to allow
for larger file sizes.
118
Administrator User Guide
Recover captures from the SSD
The PRO provides the ability to recover (copy) the contents of the internal SSD to a USBconnected media device. You may want to perform this type of recovery prior to a
factory reset of the device (device resets erase data from the device).
IMPORTANT! This is a bulk recovery process and should not be used to attempt to save
an individual capture to USB.
1. Navigate to the Administration Menu (if available) and locate the Recover data
option.
2. Once you have selected Recover data, if no USB or external drive is detected,
the device will display the option, Please Insert USB drive and Press Home to
Cancel.
As indicated, pressing the Home button on the device cancels the Recover data
option.
Use an external drive instead of a flash/thumb drive: Because this is a bulk
recovery process, we recommend that an external drive rather than a USB flash
drive be used, in order to avoid any formatting or lack of space issues that may
arise. FAT32 formatted USB drives will not accept files larger than 4GB; NTFSformatted drives do not have this limitation.
3. Once the device has detected a USB drive, it will display (in this order):




Preparing
Ready to recover and then prompts you to Start recovery. Press Enter to
confirm.
Saving. Do not remove USB drive
Finished. Please remove the USB drive.
If no USB or external drive is inserted, the operation will time out after 30 seconds.
Be Patient! Keep in mind this is a bulk recovery process and depending on the amount
of content on the SSD, it can take several hours. The device will display a progress bar
on the front panel during the process. You should not attempt to use the device for
capturing during this time.
If the recovery results in an Error please contact Technical Support.
If you do NOT see the above-listed messages, indicating successful recovery, you may
see one or more of the following messages:
119
Administrator User Guide

Insufficient space. Please insert a drive with at least <size of used space on SSD>
free.
If this message appears, the drive you have connected does not have enough
space to receive all of the recovered files. You are also presented with the
option to Recover the most recent <amount of free USB space>. This allows you
to either find another USB drive to use for recovery, OR to instead just recover as
many captures as will fit on the currently connected device, starting with the
most recent captures and working backwards.

USB drive's file system prevents files larger than 4GB. Insert a new drive or:
This message can appear when the USB drive you are using has been FAT32formatted, which has a 4GB file size limit. In this case you can attach a different
(NTFS-formatted) USB drive or select the option to Recover, skipping large files.

No space on USB drive.
This message will appear if there is no space on the attached drive or the
available drive space is not recognized (drive may need to be formatted).

Nothing to recover.
This message indicates that there is no data (or no recoverable data) on the
PRO's internal SSD drive.
FAQs
Which USB port should I use?
Either port can be used, but the USB port on the front of the device is the master
port. Meaning that if there is a USB drive in both ports, the front will be used by default.
What is the One-Touch Profile?
When the Record button is pressed on the front of the PRO to start an ad hoc capture,
the pre-configured "One-touch profile" is applied to the capture. This is configured in
the device configuration page in ALP and determines what inputs will be used for the
capture.
Administrators can change the selections made for the One Touch Profile for any or all
PRO devices. Alternately, users can use the menu options available through the frontpanel display to change the capture inputs. If there are changes made, this is
considered a Custom profile (see next FAQ) and applies ONLY to this capture. The onetouch profile is re-established as the default for the next time someone hits Record.
What is the Custom Profile?
The Echo360 PRO allows for on-demand input configuration, which is applied only to
the next capture (typically an ad hoc capture). Once the capture completes, the
device returns to the One-Touch profile as the input capture default.
120
Administrator User Guide
In order to customize the inputs used for a capture, enter the Recording menu, and use
the Configure channel inputs instructions located at the top of this page. Once
configured, the Recording menu shows Custom as the Profile.
After a recording has been captured using the custom profile, the device will
automatically default back to the one-touch profile configured for use on the device
configuration page (See What is the One-Touch Profile above).
What is 'Recovery Mode' and how should I use it?
Recovery mode will allow you to do a device reset or to access the Administration
menu to run diagnostics (if the Admin menu has been configured to be notaccessible).


To enter recovery mode: press and hold the Home button while restarting the
device (during boot up).
To exit recovery mode: restart the device normally (without holding the Home
button).
How can I monitor audio?
As an A/V technician or Administrator, an easy way to monitor audio is to plug a set of
headphones into the front of the device. The headphone jack will always have the
currently recording audio on it.
Although there is a 'Monitor Audio' selection under the Administration Menu, this is really
only meant to listen to and tune the audio levels while the device is in IDLE mode. Also,
keep in mind that the monitor audio menu will not change any settings during an
active capture.
121
Administrator User Guide
Safety Instructions and Regulations for the Echo360
PRO
This page provides the safe use instructions and appliance safety regulations for the
Echo360 PRO device. Review this page carefully before using the PRO.
Safety Symbols
Symbol
Description of Indicated Hazard
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instruction in the
literature accompanying the appliance.
Important Safety Instructions
Notification Symbol
Description of Hazard
This appliance has been designed
and manufactured to assure
personal safety. Improper use can
result in electric shock or fire hazard.
The safeguards incorporated in this
appliance will protect you if you
observe the following procedures
for installation, use, and servicing.
This unit does not contain any parts
that can be repaired by the user.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
122
Administrator User Guide
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer's instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your
outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of
time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or
has been dropped.
15. If you see smoke coming from the appliance or if the appliance gives off an
unusual odor, immediately disconnect the power cord from the wall outlet.
Failing to disconnect the power risks fire. Make sure the smoke or odor dissipates.
Then contact Echo360 or your dealer for evaluation and repair.
16. If you are concerned about the safety or integrity of the appliance:
a. Disconnect the power cord from the wall outlet AND from the appliance.
b. Contact Echo360 or your dealer for evaluation and repair.
Notification Symbol
Description of Hazard
If any electrical issue is suspected or found, disconnect
the appliance from all power by unplugging the power
cord from the wall socket AND from the appliance.
Turning off the power switch does not completely
isolate the device from AC power.
123
Administrator User Guide
Rack Mount Installation
Be advised of the following when using a rack mount installation for the PRO:





Elevated Operating Ambient Temperatures. If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment
may be greater than the room ambient. Make sure the rack environment is no
warmer than the maximum ambient temperature specified by Echo360. See
note below.
Reduced Air Flow. Make sure the rack environment has sufficient air flow.
Mechanical Loading. Mount the appliance evenly and securely.
Circuit Overloading. Do not overload the supply circuit. Overloading can
compromise overcurrent protection and supply wiring. Adhere to the ratings on
the equipment nameplates.
Reliable Grounding/Earthing. Reliable grounding of all appliances must be
maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips).
The allowable operating temperature of the Echo360 PRO device is between 0° – 50° C
(32° – 122° F). Be sure to install the device in a location where the temperature around
the unit does not exceed this limit. If operated in an environment where temperatures
exceed this limit, the unit may overheat and malfunction permanently.
Regulatory Compliance Information
FCC NOTICE
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a non-residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the appliance and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
--Consult Echo360, your dealer, or an experienced radio/TV technician for help.
To assure continued compliance, follow the provided installation instructions and use
only shielded interface cables when connecting to peripheral devices.
124
Administrator User Guide
This device complies with Part 15 of the FCC rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause
undesired operation. See instructions if interference to radio or television reception is
suspected.
L'utilisation de ce dispositif est autorisée seulement aux conditions suivantes: (1) il ne doit
pas produire de brouillage et (2) l'utilisateur du dispositif doit étre prêt à accepter tout
brouillage est susceptible de compromettre le fonctionnement du dispositif.
Changes or modifications made to this equipment, not expressly approved by Echo360
or parties authorized by Echo360, could void the user's authority to operate the
equipment.
Radio and Television Interference
This equipment generates, uses, and can radiate radio-frequency energy. If it is not
installed and used in accordance with instructions provided by Echo360, it may cause
interference with radio and television reception.
This equipment has been tested and found to comply with the limits for a Class A digital
device in accordance with the specification in Part 15 of the FCC rules. These
specifications are designed to provide reasonable protection against such interference
in an installation. However, there is no guarantee that interference will not occur in a
particular installation.
You can determine whether this appliance is causing interference by unplugging the
device. If the interference stops, it was probably caused by the equipment.
If this equipment does cause interference to radio or television receptions, try one or
more of the following techniques:




Turn the radio or television antenna until the interference stops.
Change the orientation of the appliance relative to the radio or television.
Move the appliance farther away from the radio or television.
Plug the appliance into an electrical outlet that is on a different circuit from the
radio or television.
If necessary, consult an experienced radio/television technician for additional
suggestions.
WARNING! Changes or modifications to this appliance that are not authorized by
Echo360, Inc. could void the EMC compliance and negate your authority to operate
the appliance.
This appliance has demonstrated electro-magnetic compliance (EMC) when using
shielded cables (including Ethernet cables) between system components to reduce the
possibility of causing interference to other electronic devices.
125
Administrator User Guide
Disposal and Recycling
This equipment uses a long-life battery to maintain memory settings. The battery may
not need to be replaced during the life of the appliance.
If the battery does need to be replaced, please refer servicing to Echo360 or your
dealer.
Do not dispose of this appliance with normal household or light commercial waste.
Contact your local waste disposal agency for advice.
126
Administrator User Guide
Working with Captures
As an administrator, you have a large degree of control over all of the captures in your
system. All capture-related tasks, including reviewing capture playback, are performed
through the CAPTURES page. These include:





Viewing Detailed Capture Information
Editing, Reprocessing, and Deleting Captures
Adding Captures
Uploading Captures
Publishing and Sharing Captures
To schedule captures for sections, see Scheduling Sections.
Navigating the captures page
Since there are probably a LOT of captures in your system, we've tried to make the
CAPTURES page easy to filter, sort, and search, so you can quickly get the information
you need.
The page can be filtered by status, using the status bar across the top of the captures
list. The status bar also shows the number of captures in that particular state.
The page can be filtered by date, source, instructor, or other criteria as needed, using
the expandable categories on the left, to find the capture or set of captures you need.
Enter text into the Search box to search for captures by name, capture room or
building, section, or data tag.
The list can be sorted by clicking a column header. The current sort column appears
with a small triangle to the right of the column name. If the triangle is pointing down, the
sort is Descending; pointing up indicates Ascending.
127
Administrator User Guide
Review capture playback
Besides viewing the details of a capture and access to other functionality, you can
review the capture playback in the capture details page.
To review a capture
1. From the Captures page, find the capture you want to review.
2. Click on the capture.
The capture details page opens, including playback controls.
3. Click play to play the capture, using the volume control, speed control, and
playback bar to control those aspects of the capture playback.
128
Administrator User Guide
Viewing Detailed Capture Information
Detailed capture information is available for captures that have completed or those
that have errored out. Clicking a capture from the Completed or Errors list of captures
opens the capture's details page, providing information and a variety of functionality.
To view detailed capture information
1. From the Completed or Errors status list on the CAPTURES page, find the capture
you want.
2. Click on the capture row.
The capture details page appears. A completed capture is shown in the figure
below.
3. Below the capture preview, the capture Info tab is shown by default. Click Info
to return to this tab at anytime.
For completed captures, the info includes capture and upload timing, device and
publishing information, and other details, as shown in the below figure.
129
Administrator User Guide
For errored and failed captures, the bottom of the page shows the Events that
occurred around the capture, and will indicate whether the capture was missed
(possibly due to a device being offline) or if the failure occurred during capture, upload
or processing.
130
Administrator User Guide
131
Administrator User Guide
Editing, Reprocessing, and Deleting Captures
As the administrator of the system you have the ability to manipulate the captures in
the system, including editing videos, editing media details, or deleting captures. You
can also Publish from the captures page.
You can only edit details for or reprocess completed captures. You can delete any
capture as long as it is not currently in the Capturing state.
Captures page options
Editing details, reprocessing a capture and deleting a capture can all be done from
the CAPTURES page.
Hovering over a completed capture row exposes a chevron (menu arrow) on the right
side of the row.
Clicking the chevron opens a menu with the appropriate commands.
Deleting a capture in any other state (except capturing) can also be done from the
CAPTURES page.
Hovering over a capture row from another state list exposes a trash can icon on the
right side of the row.
Clicking the trash can deletes the capture. You will be asked to confirm the deletion.
132
Administrator User Guide
Reprocess a capture
Completed captures can be reprocessed if needed. For example, if you add a
branding watermark or video intro/outro to the system, you can apply the branding to
existing captures by reprocessing them.
To reprocess a capture
1. From the Completed status list on the CAPTURES page, find the capture you
want.
2. Hover over the capture row and select Reprocess from the chevron menu as
described above.
The capture is sent back to the media processor and reprocessed. When finished, the
newly processed capture replaces the originally selected capture in all locations where
it appeared.
Edit a capture or video
Completed captures/processed videos can be edited if needed. Typically the "owner"
of the video is the person responsible for editing, however Administrators also have that
ability if needed or if your institution's workflow requires it.
REMEMBER: Editing a video edits every published version of that video; the changes you
make will appear in all linked instances of the video.
To edit a capture/video
1. From the Completed status list on the CAPTURES page, find the capture you
want.
2. Hover over the capture row and select Edit video from the chevron menu as
described above, or select the Edit video icon from the capture details page
133
Administrator User Guide
shown below.
3. Edit the video (trim the ends or cut segments) as needed. See Editing a Video for
detailed instructions.
Once you complete the edits, the video is reprocessed. You can view the final product
or edit the media details once it re-appears in the Completed captures list.
Edit capture media details
As an administrator, you have the ability to edit the details of any capture media,
including the Title of the capture, the description, as well as any tags that have been or
need to be added.
To edit capture details
1. From the Completed status list on the CAPTURES page, find the capture you
want.
2. Hover over the capture row and select Edit details from the chevron menu as
described above,
OR
Click on the capture row to open the capture details page, then click the pencil
134
Administrator User Guide
icon located above the capture preview, as identified in the below figure.
3. In the Edit media info dialog box, enter or edit the Title, Description, and/or Tags
as necessary. Separate multiple tags with commas.
4. Click SAVE.
The capture details page refreshes to show the new title and/or description.
Delete a capture
As an administrator, you may need to delete captures from the system, if they are no
longer needed or if they are not completing properly and need to be re-captured.
135
Administrator User Guide
You cannot delete a capture that is in Capturing status. All other captures can be
deleted.
Deleting a capture is permanent and cannot be undone.
NOTE: If you delete a capture that has been published to one or more sections, you will
also delete all student notes, all Q&A, and all analytics associated with that capture.
You will receive a dialog box confirming this is what you want to do.
To delete a capture
1. On the CAPTURES page, find the capture you want.
2. Hover over the capture row and select Delete from the chevron menu or the
Trash can icon, as described at the top of this page,
OR
Click on the capture row to open the capture details page, then click the trash
can icon located above the capture preview, as identified in the below figure.
3. Review the warning message in the confirmation dialog box. (Seriously, someone
wrote that warning to let you know the consequences of your actions. You can't
undo this.)
4. Click OK to confirm the deletion.
136
Administrator User Guide
Editing Videos
The Active Learning Platform provides a basic video editing function, allowing you to
make cuts and trims to video content as needed.
IMPORTANT! CHECK PUBLISHING INFO FIRST!!
Any changes you apply to a video in your library will also appear in ALL published (or
shared) versions of the video, even if you select to edit the video from the Class List
page. Sharing/Publishing simply provides links to the original content located in your
library. When you change your library content, you change the content being
delivered via those links.
To edit a video
1. Open your LIBRARY page.
2. Find the video you want to edit, then hover over the content tile or row to
expose the menu arrow (also called a "chevron").
3. Click the chevron and select Edit video from the options.
The video opens in the ALP editor.
4. Use the playback controls, Make cut and Delete/Revert (toggle) buttons at the
bottom of the editor to make changes to the video.
Editing functionality is described in detail below.
5. Use the Restore and Apply Edits buttons across the top to save or undo all
changes made to the video as appropriate. These buttons apply to the video as
a whole, and work as follows:

RESTORE - Reverts all changes ever made to the video and restores the
original video file.
137
Administrator User Guide

APPLY EDITS - Acts as a save button. Applies the changes you've made to
this video and which are reflected in the playback bar at the bottom of
the editing screen.

NOTE: If you Apply edits, all published (and shared) versions of this video
will show this version of the video including these changes.
6. To exit without making or saving any changes, click the back arrow in the top left
corner of the video editing screen. This returns you to the LIBRARY page.
Using the video editing tools
The ALP video editor allows you to trim the ends and cut segments from the video. You
can review the changes to the video, playing it with the cuts in place, prior to making
your changes permanent.
Review/Playback the video
Use the playback controls to play the recording. If you have made cuts in the
recording, the playback will skip the cut areas, so you can see how the edits affect the
final product.
The figure below shows the playback controls, and has the current location of the
playhead identified, both as the timed location, and within the playback bar itself.




Click play to show the video in the editing window.
Click pause to pause the playback. This lets you place the playhead in a specific
location for making a cut. See Cutting segments from the video section below.
Use the forward and rewind buttons to move through the video as needed.
Use your mouse to click-and-drag the playhead to various locations in the
playbar.
138
Administrator User Guide
Cutting segments from the video
Known issue with video editing: When applying many small cuts (20 or more) to a video,
the audio/video can become out of sync, sometimes by as much as half a second. We
are addressing this issue; once resolved this note will be removed.
Cutting segments in the ALP video editor involves identifying each end of the cut, then
selecting to make the cut. All cuts are temporary until you choose to Apply Edits or
Save As.
Once the cuts are in place, you can review the edited video in the window. The
playback head will skip over any cuts so you can see how the recording will look when
it is published.
Moving the playhead marker There are three ways to place the playhead marker in a
specific location:
-- Play the video and pause it where you want to apply a cut
-- Click and drag the playhead marker in the playbar to the location for the cut
-- Hover the mouse over the playbar, then click in the playbar to the location for the cut
To cut a segment from the video
1. Put the playhead marker at the beginning location of the segment you want to
cut.
2. Click MAKE CUT.
3. Move the playhead marker to the end location of the segment you want to cut.
4. Click MAKE CUT.
5. Click into the area between the cuts to select it (yes this also moves the
playhead into that area; ignore it).
Notice that the selected area in between the two cuts changes to a lighter color
than the rest of the playbar, as shown in the below figure.
6. Click DELETE to temporarily cut that segment from the video.
The cut segment turns gray, to indicate it is no longer part of the playback.
Repeat these steps for each segment you want to remove from the video. The below
figure shows a video with multiple cut segments. Remember, these cuts are temporary
until you save your changes via Apply Edits or Save As.
139
Administrator User Guide
To trim the ends of the recording
1. Put the playhead marker at location where you want the video to start.
2. Click MAKE CUT.
3. Click into the area preceding the cut (the current beginning section of the
video) to select it.
Notice that the selected area changes to a lighter color than the rest of the
playbar.
4. Click DELETE.
The opening segment turns gray to indicate it is no longer part of the playback.
5. Move the playhead marker to the location where you want the video to end.
6. Click MAKE CUT.
7. Click into the area immediately following the cut (the current end section of the
video) to select it.
Notice that the selected area changes to a lighter color than the rest of the
playbar.
8. Click DELETE.
The end segment turns gray to indicate it is no longer part of the playback. This is
shown in the above figure.
To revert cut segments (undo cut deletion)
1. Click into a gray cut segment on the playbar.
Notice that the DELETE button changes to REVERT.
2. Click REVERT.
The segment returns to the same color as the rest of the playbar to indicate it is
again part of the playback.
140
Administrator User Guide
Add Captures
Captures are typically generated as a function of scheduling classes for the section.
However, there are some times when you may need to record some event or session,
either as a standalone or as a repeated series of captures that are not specifically
associated with a section.
NOTE: Captures that are not associated with a section will ONLY appear in the selected
Instructor's LIBRARY (and on the Admin's CAPTURES page). Either the Admin or the
Instructor will have to publish the capture to make it viewable by other users.
ALTERNATELY you can copy the public link for a completed capture and post it
anywhere you like. This allows allow non-ALP users to view the media and may be an
option if publishing does not provide sufficient access.
This topic deals with configuring standalone captures not associated with a course
section. For adding one-time or scheduled captures for a section, see Scheduling
Sections. For information on using a CSV import to configure scheduled captures
(either for a section or outside of a section) see Scheduling Captures via CSV Import.
As with all captures, you must identify a room for the capture, which in turn identifies the
device that will be doing the capturing. Captures can only be added for rooms where
a capture device has been added.
Finally, adding captures outside of sections does not provide the Live Stream option. If
you need to set up a live streaming class that is not associated with a particular course
or section (available to a wider audience), set up a special events section and
schedule a live capture for the section. Be sure to assign all appropriate users to the
section. See Configuration Requirements for Live for additional information.
To add a capture
1. Select CAPTURES to open the Captures page.
2. At the upper-right of the page, click ADD CAPTURE.
3. Enter a Title for the capture.
4. Use the lists to select a Campus, Building, and Room where the capture will
occur.
5. Select an Instructor from the list. This is the user with whom the capture will be
associated and in whose library the capture will appear.
6. If applicable, enter a Guest Instructor. This name will appear in the capture
details along with the primary instructor.
7. Enter the Time Range for the capture.
8. Select whether the capture repeats or not. Your options are:


None (one-time event)
Weekly (creates a recurring event on one or more days a week).
141
Administrator User Guide
9. For a one-time event, enter the Date for the capture. Today's date appears by
default. Clicking the date field opens a calendar view for selecting a date, or
you can type the date into the field (yyyy-mm-dd).
10. For recurring events you must:



Identify both a Start date and End date for the capture (the first and last
dates the capture will occur).
Identify the weekly frequency of the capture; enter 1 for every week,
enter 2 for every other week, etc.
Use the sliders to identify on which days each week the capture is to
occur.
As you make changes, the calendar preview changes to reflect the schedule
information entered on the page. Today's date is transparent and circled; dates
on which the recurring captures are scheduled are marked with colored circles.
11. Expand the Options (click the triangle icon on the right side of the Options
banner).
142
Administrator User Guide
12. Select whether to Auto-Publish the capture(s) when they are completed. All
captures are automatically published to the primary instructor's capture library.
You or the instructor will need to publish the capture(s) to a course for students to
view it.
13. Select whether to enable Closed Captioning for this capture. This option only
appears if you have closed captioning configured for the system.
14. Review and set or change the A/V sources and capture quality. The defaults set
for the device appear initially but can be changed as needed.
15. When finished, click SAVE.
143
Administrator User Guide
Uploading Captures
There are some times when you may need to manually upload a capture or other
video to the Active Learning Platform. The Upload Capture functionality for
administrators only allows uploading of video media.
IMPORTANT: If you upload the capture, you are the "owner" of the capture, meaning
you are the only one who can edit the media or edit the details (name, description,
tags) of the content. You can publish it to a section or share it with another user, but
that user cannot edit the media or details. See Changing ownership below for
additional information.
To upload existing captures
1. From the main menu, select CAPTURES.
2. In the upper-right corner of the captures page, click UPLOAD CAPTURE.
3. In the Filepicker window, use the left panel to identify the location of the file,
then follow the prompts. It MUST be a supported video file type. If the file is saved
locally, click Choose File from the window, and navigate to the capture file to
upload.
4. Click UPLOAD.
Once the capture has been uploaded and processed, you will likely want to share it
with an instructor (so it appears in their library) or publish it to a section for
student/instructor viewing.
Changing ownership
The "owner" of a capture or presentation is determined in either of two ways:


The Instructor selected when the capture schedule is configured is the owner
and has full control over the capture.
The user who uploads the capture is owner and has full control over the item.
Ownership is important because the owner can edit the content (edit the presentation
or video) and can edit the details about the item (Name, Description or Tags). The item
also appears in the owner's My Content page of their LIBRARY. This allows them to
publish the item to a class or to share it with other users.
As an Admin, if you are the user who uploads content for an instructor or class, you are
still the owner; the instructor cannot edit the item or control it in any way.
In order to obtain ownership of a piece of content, a user must be able to download
the item, then re-upload it to their own library. This creates a new version of the file that
is now owned by the user who uploaded it. The files are not associated with each other
in any way, even though they may be identical.
144
Administrator User Guide
To change ownership of content
1. Share the item with the user who is to own it (share/publish to an individual).
The item should now appear in the Shared with me page of their LIBRARY.
ALTERNATELY if you published the content to a class, the user should be able to
download it from the Class, eliminating the need for you to share the content
with them specifically.
2. The target user must download the shared content by clicking the chevron
menu for the item and selecting Download/Download original.
3. The user uploads the file through their LIBRARY page.
The item now appears in the My content page of their LIBRARY. They can edit all
aspects of the media as well as publish it to a class (if they are an instructor) and
share it with other users.
Difference between edited videos/capture and presentations: If you edit a presentation
file before you share it, when the target user downloads the file they will get the
originally uploaded file, not the edited version. For edited videos or captures, the user
gets the file as shared (edited or otherwise).
145
Administrator User Guide
Publishing and Sharing Captures
Captures can be published to one or more sections, or shared with one or more
individuals. Captures created for sections are typically auto-published when they are
scheduled. However you may need to manually publish a capture to one or more
additional sections/classes.
ALTERNATELY, you can copy the public link for a video and post it anywhere you like, to
allow non-ALP users to view the media. This may be an option if publishing does not
provide sufficient access.
Publishing a capture to a class
"Publishing" simply means "putting the capture into a class so students and instructors
can view it".
To publish a capture to a class
1. From the Completed or Errors status list on the CAPTURES page, find the capture
you want.
2. Click on the capture row to open the capture details page
3. Below the capture preview, click Publishing. Existing publishing information for
the capture appears, as shown in the below figure.
4. Click PUBLISH. The Publish to a new location dialog box appears.
5. Select To a course.
6. From the drop-down list, select the course/section from the list.
7. Select whether to create a New class or publish the capture to an Existing class.
146
Administrator User Guide
8. If you create a new class to hold the capture, enter the Class name, Start date,
Start time, Duration, and optionally a Description.
9. If necessary, select Availability details:
Now - Makes the capture visible immediately to the individual or section.
This is the default.
 On a specific date - Makes the capture available as of the date entered
(yyyy-mm-dd).
To set a window of availability, also select On a specific date under the
Make Unavailable section, and enter the date the capture is to become
unavailable.
 Don't make available - Publishes the capture to the location (typically a
section) but not available for student viewing. The instructor will see the
capture in the class page, and can make the capture available to
students as appropriate.
10. Click PUBLISH.

Sharing a capture with another user
"Sharing" is the act of making a capture available to an individual by adding it to the
Shared with me section of their LIBRARY page.
If the user you are sharing the capture with needs to have full control or "ownership" of
the item you are sharing, they will need to download then re-upload the content. See
Changing Ownership for further details.
147
Administrator User Guide
To share a capture with a user
1. From the Completed or Errors status list on the CAPTURES page, find the capture
you want.
2. Click on the capture row to open the capture details page
3. Below the capture preview, click Sharing. Existing sharing information for the
capture appears, as shown in the below figure.
4. Click SHARE. The Share to user dialog box appears.
5. Enter the email address of the user you want to share the capture with. Separate
multiple addresses with commas.
6. When finished, click SHARE.
The new sharing information appears in the list below the capture.
The users to whom you shared the item should now see it in the Shared with me page of
their LIBRARY. From there they can download the item or delete it when no longer
needed.
148
Administrator User Guide
Getting a Video's Public Link (for Admins)
There may be some times when you need to share a capture with a larger audience
than a few classes or select individuals. In this case, you can copy the public link for a
video, then post that link anywhere you like. This allows anyone who can access that
location to view the video in a browser.
This option is only available for videos, and is only available for captures/videos listed
with the Completed status.
This is different than sharing/publishing a video to an individual. In that case, the
recipient must be a registered ALP user.
To copy the public link for a video/capture
1. From the Completed status list on the CAPTURES page, find the capture you
want.
2. Click on the capture row to open the capture details page.
3. Select the Copy public link icon from the capture details page as shown below.
The public link to the video is copied to your clipboard.
4. Paste the link (using the receiving program's menu commands, or use
CTRL+V/Command+V) into the location of your choice. You may want to paste
the link temporarily into Notepad or other text editor, for retrieving later.
Users outside of ALP can click the link and view the video. The playback window
provides basic playback controls but does not have the navigation or other options
that users within ALP have.
149
Administrator User Guide
Controlling Captures Through Device Web Interface
Active captures being performed by an SCHD or PRO appliance can be controlled
through the device.
For an SCHD appliance, you need to log into the device and open the device's web
interface.
For an Echo360 PRO appliance, users can use the menu options on the front panel of
the device to manipulate a current capture, or use the Record button to initiate an ad
hoc capture. The configured "one-touch profile" input settings are used for ad hoc
captures. For more information, see Start an ad hoc recording.
However, the PRO also allows for controlling captures through the device web
interface.
The device web interface can be used to:





Initiate an ad hoc capture
Start a scheduled capture early
Pause an active capture
Extend a capture by 10 minutes
Stop an active capture
This topic deals with controlling active or scheduled captures through the device
interface. See Ad Hoc Captures for ad hoc capture information. See the Classroom
Capture documentation for information on using the Classroom Capture interface.
Alternately, you can obtain a device monitor light and install the device monitor
software available from Echo, to control or initiate captures from within the classroom.
The Device Monitor documentation is currently available as a downloadable PDF.
If you use a Device Monitor and light, a user must be logged in to the PC for the device
and software to work.
Log in to the SCHD or PRO device web interface
Any type of capture being performed by a capture appliance can be controlled
through the device web interface. You must log in to the device through the device IP
address to access the web interface controls.
You may be presented with security warnings when accessing the device. You can
ignore these warnings.
If you are an instructor and do not know the IP address of the device, contact your
system administrator.
To log in to the SCHD device web interface
1. To access the device directly, you have the following options:
150
Administrator User Guide
If you are an Admin:
o Select ROOMS from the main menu, find the room with the device,
and click the Log in to Device icon located in the bottom left corner of
the Room block.
o Alternately, you can enter the IP address/advanced into the browser's
URL field.
 If you are an Instructor, enter the IP address of the device into your
browser's URL address field. This may be noted somewhere or bookmarked
on the computer in the classroom.
2. Log in to the device as follows:



If you are an Admin, use the generic admin or instructor login configured
for the device.
If you are an Instructor, use your Active Learning Platform login, or the
generic instructor login for the device.
When the device interface appears, the first tab shown is the Captures tab, used to
start an ad hoc capture or control a currently active capture.
Controlling an active capture
If you log into a device that is currently engaged in an active capture, or where a
scheduled capture is due to start in the next few minutes, the Capture tab shows a set
of control buttons for the capture.
The buttons shown depend on the current status of the capture. The options may
include:




If there is a capture currently occurring, you can Stop, Pause, or Extend the
capture.
If the capture is currently paused, there is a Resume button available.
If a scheduled capture is slated to start, you can select to Start Capture Early.
If a scheduled capture has moved into the "Waiting" state (the 5 minute window
before the capture is scheduled to start), you can select to Cancel the capture.
To extend an active capture
1. Use the IP address of the device to access and log in to the device web
interface (see above instructions).
2. On the Captures tab, select Extend Capture.
3. Enter the number of minutes to extend the recording time (default = 10 minutes).
The system will NOT allow you to extend a capture beyond the start time of the
next scheduled capture.
4. Click OK.
151
Administrator User Guide
To stop an active capture
1. Use the IP address of the device to access and log in to the device web
interface (see above instructions).
2. On the Captures tab, select Stop Capture.
3. Click OK to confirm action.
NOTE: Captures are automatically finalized and uploaded to the Active Learning
Platform upon completion, either because the configured end time occurred, or
you selected to manually stop the capture. To temporarily suspend the capture,
use Pause Capture instead.
To pause an active capture
1. Use the IP address of the device to access and log in to the device web
interface (see above instructions).
2. Select Pause Capture. The Pause Capture label changes to Resume Capture.
Monitoring captures
Monitoring is a great tool for troubleshooting. You can monitor the video and display
inputs as part of configuration testing and to verify the signal during capture.
To monitor an active capture
1. Use the IP address of the device to access and log in to the device web
interface (see above instructions).
2. Select the Monitor tab.
3. Select Start Monitoring to initiate a 15-minute monitoring session.
152
Administrator User Guide
Ad Hoc Captures
Ad hoc captures are generated outside of a regular class schedule.
For an SCHD device, ad hoc captures are started and controlled through the Device
web interface, which allows a user to log into and control the capture device assigned
to the room. These instructions are provided below.
For an Echo360 PRO appliance, users can simply press the Record button on the front of
the device. The configured "one-touch profile" input settings are used for the capture.
For more information, see Start an ad hoc recording.
Alternately, you can obtain a device monitor light and install the device monitor
software available from Echo, to initiate and control adhoc captures within the
classroom. If you use a Device Monitor and light, a user must be logged in to the PC for
the device and software to work.
The ad hoc interface is available with the following capture options:
SafeCapture HD (SCHD)
 Echo360 PRO (PRO)
 Classroom Capture Software
Like scheduled captures, when an Ad Hoc capture is completed (user clicks Stop
Capture), the raw capture files are automatically uploaded to the Active Learning
Platform for processing.

NOTE: Admin-initiated ad hoc captures not associated with a section will ONLY appear
on the Admin's Captures page. Instructor-initiated captures can be published to a
selected course or to the instructor's Personal Library. If Personal library is selected, the
capture will appear on the LIBRARY page where it can be viewed or edited prior to
publishing to one or more classes.
In either case, the capture will need to be published in order to be viewable by other
users.
Log in to the SCHD or PRO device web interface
Any type of capture being performed by a capture appliance can be controlled
through the device web interface. You must log in to the device through the device IP
address to access the web interface controls.
You may be presented with security warnings when accessing the device. You can
ignore these warnings.
If you are an instructor and do not know the IP address of the device, contact your
system administrator.
To log in to the SCHD device web interface
1. To access the device directly, you have the following options:
153
Administrator User Guide
If you are an Admin:
o Select ROOMS from the main menu, find the room with the device,
and click the Log in to Device icon located in the bottom left corner of
the Room block.
o Alternately, you can enter the IP address/advanced into the browser's
URL field.
 If you are an Instructor, enter the IP address of the device into your
browser's URL address field. This may be noted somewhere or bookmarked
on the computer in the classroom.
2. Log in to the device as follows:



If you are an Admin, use the generic admin or instructor login configured
for the device.
If you are an Instructor, use your Active Learning Platform login, or the
generic instructor login for the device.
When the device interface appears, the first tab shown is the Captures tab, used to
start an ad hoc capture or control a currently active capture.
Create ad hoc captures
Ad hoc captures are generated in a classroom but outside of the normal class
schedule. Ad hoc captures can be associated with a particular section when they are
initiated, or published to a section later through the Active Learning Platform interface.
For Your Information: The room info for a capture device is located in the upper-right
corner of the screen. If it applies, information for Next Scheduled Capture is provided in
the center of the screen. Ad hoc captures cannot be configured to overlap the next
scheduled capture start time.
To start a new ad hoc capture
1. Log in to the device web interface (see above instructions).
2. On the Captures tab of the device interface, select Ad Hoc Capture.
3. The tab changes to contain fields to complete relating to the capture:
Title this capture - Enter a title related to the subject or purpose of the
capture.
 How many minutes is the capture? - Enter how long you want the capture
to be. You can extend or stop the capture at any time.
 What do you want to capture? - Use the list to select the input items and
quality (which also determines file size) you want to use for this capture.
 Select an upload location- If you used a specific instructor login, you are
able to select the section to which this capture should be associated, or
select Personal library.
4. When the fields are complete and you are ready to begin capturing, click Start
Ad Hoc Capture.

154
Administrator User Guide
NOTE: The maximum duration of any ad-hoc capture is 4 hours. This limit is enforced by
the system.
After selecting to start the capture, there is a three-second countdown before the
capture begins. At this point you may want to click the Monitor tab to view the inputs
and monitor the capture.
155
Administrator User Guide
Recovering Ad Hoc Captures
Ad hoc captures are captures generated outside of a regular class schedule. They are
typically started and controlled through the Device web interface, or possibly by using
the device monitor light.
The procedure on this page shows how to recover an ad hoc recording that was
captured successfully by a capture appliance but for whatever reason was not fully
uploaded or was inadequately processed by ALP. In these cases, the capture exists on
the device but needs to be reprocessed for viewing.
Log into the SCHD device using the device's IP address or via the ROOMS page. These
instructions are below.
To log into the SCHD device
You may be presented with security warnings when accessing the device. You can
ignore these warnings.
1. To open the web UI for the device, you have the following options:
Select ROOMS from the main menu, find the room with the device, and
click the Log in to Device icon located in the bottom left corner of the
Room block.
OR
 Enter the <IP address>/advanced into the browser's URL field.
Example: https://10.3.10.246:8443/advanced
2. Enter the generic admin login configured for the device.

3. Select the Diagnostics tab of the Device web interface.
4. Click the Recover button.
The Reupload Content list opens in a new tab.
5. In the Reupload Content list, find the capture(s) you want to re-upload to ALP.
156
Administrator User Guide
6. Use the checkboxes to select one or a few captures, or use the Select All button
to re-upload all ad hoc captures from the device to ALP.
7. Click Reupload.
A confirmation message appears indicating that the submission has succeeded.
If you get a different message, check the network connectivity of the device.
You can open the Captures list in ALP to view the status of the reuploaded capture(s).
Once reprocessed, the captures are available for sharing with instructors or publishing
to sections as necessary.
TIME STAMP MAY DIFFER BETWEEN DEVICE UI AND ALP: When an ad hoc capture is
reuploaded and reprocessed, the time/date stamp shown in the Device web UI for the
capture is in UTC; this may be different than the date/time the capture was created
locally. The LOCAL time (time that the capture was created) is applied to the
reuploaded/reprocessed capture.
For example, a capture stamped as June 10, 2014 4:30pm UTC in the Device UI (see
above figure) is reprocessed, and the date/time shown in the Captures page on ALP is
June 10, 2014 12:30pm EDT. This is because the capture was created at 1230pm local
time. The date will not change unless the difference between UTC and the local time
crosses the pm/am date line.
157
Administrator User Guide
Device Monitor Overview - Administrators
In the Echo360-speak, the term Device Monitor refers both to a small light attached to a
classroom PC, as well as to the software that makes the light work with our system. The
light is also sometimes referred to as a "puck-light".
This light has two functions:


The light color/flash pattern indicates the status of a capture currently occurring
If configured to do so, the light acts as a button; pressing it can start, stop,
pause, or resume a capture.
Strictly speaking, however, the Device Monitor is actually the software. It is a Windowsonly application designed to work with the Delcom USB HID Visual Signal Indicator (the
formal name of the light). The Device Monitor software connects the light to the
capture device, either an SCHD device or a Classroom Capture installation, and
provides a communication avenue between the light and the device.
The Delcom USB Visual Signal Indicator is a small light that attaches via USB port to a
classroom PC. It is available from Delcom Products, product number 904007-SB:
http://www.delcomproducts.com/productdetails.asp?productnum=904007-SB.
Together, these products provide a visual confidence monitor to instructors and
students on the state of a capture device while recording. The Device Monitor software
also allows users to pre-configure logins and section selections so that instructors can
quickly initiate an ad hoc recording without needing to log into the device and use the
device interface.
The Echo360 Device Monitor 1.9.4 is available through the Echo360 Customer Portal at:
http://echo360.com/customer-portal.
VERY IMPORTANT!! The PC must be on and a user must be logged in for the Device
Monitor to work. While it does run in the background, it does not run as a service.
158
Administrator User Guide
Installing the Device Monitor Software
The zip file containing the device monitor software can be obtained from the Echo360
Customer Portal.
To install the device monitor software:
1. Unzip and extract the downloaded file.
2. Double-click the setup.exe file.
3. Follow the wizard prompts to install the software.
4. Click Finish to complete installation.
Once installed, you can plug the Delcom light into the PC.
After that, review the following topics for further Admin-level information on configuring
and using the Device Monitor and associated light:







Device Monitor for Admins
Launch the Device Monitor
Device Configuration Defaults
Ad hoc Capture Defaults
Device Monitor Light Defaults
Using the Light to Control the Capture
Device Monitor Admin Override
Instructors should review the following topics as needed:





Device Monitor Light Overview - Instructors
Using the Device Monitor Light - Instructors
Device Configuration Defaults
Ad hoc Capture Defaults
Manually Launch the Device Monitor
159
Administrator User Guide
Launch the Device Monitor
The Device Monitor software is configured to start when Windows starts. Even if the
Device Monitor icon does not appear in the System Tray, the Device Monitor is active
and the light should show current capture status and allow you to press it to start, pause
or otherwise control a capture.
To manually launch the Device Monitor:


Double-click the Device Monitor icon on the desktop, OR
Click Start > Echo360 Device Monitor
If they have not been configured, you will be prompted to complete the Device
Configuration defaults and Adhoc Capture settings. These can be done with generic
information (applicable to all users) or with instructor-specific information. The
information entered is retained on a per-user basis, so that each logged in user can
have their own configurations.
Once launched, the Device Monitor can be controlled through the Windows System
Tray icon, which looks like the Echo360 logo. Click this icon to open the Device Monitor
menu options, as shown in the below figure.
160
Administrator User Guide
Device Configuration Defaults
VERY IMPORTANT!! The PC must be on and a user must be logged in for the Device
Monitor to work.
Select Echo360 Configuration from the device monitor system tray menu. Device
configuration means identifying, via IP address, the device (either Classroom Capture
or an SCHD) you want to communicate with through the light, as well as entering the
username and password needed to authorize an ad hoc capture.
Each user can enter their instructor login, or a generic instructor login can be used.
These settings are retained on a per-user basis.
Alternately the Admin may choose to use an Admin Override to configure the same
login information for all users.
Best Practice - Have Instructors Configure Their Own Defaults
Let each instructor log into the PC and then configure the Device Configuration
defaults using their Active Learning Platform logins. This information will be used each
time that user logs into the PC and initiates an adhoc capture using the Device Monitor
light.
To set Device Configuration defaults:
1. Open the System Tray menu, shown above, and select Echo360 Configuration.
The Device Configuration dialog box appears, as shown below.
2. Device Url: Enter the fully qualified URL for the capture device you want to
control with the light. This is typically the IP address for the device, such as
https://10.3.10.245:8443.
To find the IP address, navigate to the ROOMS page, and click the log in to
Device icon (bottom left corner) of the Room tile. Be sure to use the IP address
but do not add “/advanced” to the end of the URL; the /advanced URL requires
an Administrator login.
3. Credentials: Enter the username and password that will be used to log into the
device and initiate or control a capture.
161
Administrator User Guide
Note the following:


If an instructor login is used, the instructor will be able to select a section for any
initiated Ad hoc capture.
If a generic login is used, any Ad hoc captures will need to be manually
published to a section.
162
Administrator User Guide
Device Monitor Adhoc Capture and Settings
The Adhoc Capture configuration allows you to set default information to be used for
any adhoc capture initiated through the device monitor.
If an instructor provides their personal credentials in the Device Configuration dialog
box (above), the adhoc capture defaults (configured below) will be used for all
captures initiated via the Device Monitor Light after the instructor logs into the PC. If for
some reason the user cannot be authenticated or is not associated with a particular
course or section, the capture can proceed, but will use generic capture settings and
will need to be assigned to a Section later through the CAPTURES page in ALP.
Perform Device Configuration First
You must complete the Device Configuration (shown above) before you can configure
the Adhoc Capture Settings defaults. The Product Group selections for adhoc capture
defaults require the system to know what type of device is being used for capture.
To set Ad hoc Capture defaults:
1. Open the System Tray menu and select Ad hoc Capture and Settings.
Depending on the credentials entered, one of the following Ad hoc Capture
dialog boxes appears.
Ad hoc Capture dialog box for generic instructor login:
Ad hoc Capture dialog box for user-specific instructor login:
163
Administrator User Guide
The two Ad hoc Capture dialog boxes are identical except for the ability to
select a Section to which to publish the capture.
2. Enter information to apply to all adhoc captures initiated through the Device
Monitor. These will be used unless manually overridden by the user:
Default Capture Description: Provide a generic description for the capture
that identifies it clearly. You may want to use Room or Device information,
so that you can contact possible instructors and direct the adhoc
capture to the proper section.
OR
 Default Capture Title: If instructor credentials are entered, a Section can
be identified and a more specific Title can be entered, identifying the
basic subject matter for the capture. The Instructor can edit this later if
necessary.
 Duration: Indicate how long you generally want adhoc captures to be.
Instructors can to stop the capture early, or extend the capture if
necessary. Keep in mind if there is a scheduled capture for the room, the
adhoc capture cannot extend into the scheduled capture time.
 What do you want to capture?: This identifies a Product Group for the
adhoc capture, indicating what inputs you want to include, like
Video/Display or Audio/Video. The Product Group selected here will be
retained for all captures unless changed by the user.
3. When finished, you can:



Click Save to retain the settings,
Click Capture to retain these settings and immediately initiate a capture.
164
Administrator User Guide
Device Monitor Light Defaults
VERY IMPORTANT!! The PC must be on and a user must be logged in for the Device
Monitor to work.
The Device Monitor light indicates the current status of the capture using both steadystate and blinking LED lights of different colors. The default setting are shown below but
can be changed.
By default, the light indicator settings are as follows:







Light Off - The recording device is idle OR the device monitor software is not
running or is not communicating with the recording device.
Steady Red Light - The device is currently recording. The Inputs being recorded
(audio, display, video) are determined by the Product Group selected for the
capture in the adhoc capture settings (configured in the section above).
Steady Yellow Light - The device is currently preparing to start a capture (called
"Waiting" mode).
Flashing Yellow Light - The capture is currently paused. No inputs are being
captured.
Flashing Green Light - The capture has been stopped and capture processing is
being completed. The light will turn off when finished.
Flashing Red Light - There has been an error capturing or communicating with
the recording device. You may need to stop and then start a new capture.
Steady Green Light - Not used by default but can be configured for any of the
LED states.
In addition to selecting different light indications for different states, the Device Monitor
Configuration dialog box allows you to enable or disable the following indicators:



Disable All Delcom Button Gestures: Unchecked by default, this allows you to
disable the use of the light itself as a button to control (start, stop, pause)
captures. The light will still show capture status via color/flash combination, but
cannot be pressed to control the capture as it is occurring.
Disable select Delcom button gestures: If disabling all gestures is not appropriate,
you can select which capture control features can be enacted by pressing the
light and which cannot. For example, the Configuration dialog box shown in the
below procedure is set to allow the instructor to pause or resume a capture by
pressing the light, but does not allow them to start or stop a capture.
Set Audio Level Warning (bottom of dialog box): Unchecked by default, this
allows you to let the light indicate whether the audio level of the capture is too
low. In addition, you can set the Audio Level Threshold (in minutes) that will
trigger the warning. For example, if this warning is enabled and the Threshold is
set to 2, you will see the warning indicator when the audio signal has not been
detected for two minutes.
165
Administrator User Guide

End of Capture Warning (bottom of dialog box): Unchecked by default, this
allows you to let the light indicate when the end of the scheduled capture is
approaching. In addition, you can set the End of Capture Threshold (in minutes)
that triggers the warning. For example, if this warning is enabled and the
Threshold is set to 5, you will receive the warning indicator when the capture is 5
minutes from completing.
To view or change Device Monitor Light settings:
1. Open the System Tray menu and select Device Monitor Configuration.
The Device Monitor Configuration dialog box appears, shown below.
2. Use the Checkboxes described above to enable or disable features of the
monitor and light.
3. Use the drop-down lists to set a different light color or state for each LED State.
A full drop-down list with all possible selections is shown below.
4. Use the Power levels to set how bright you want each light-state to appear via
the Delcom light. A higher Power level indicates a brighter light.
5. When finished, click Apply to apply the changes, or OK to apply the changes
and close the dialog box.
166
Administrator User Guide
The below figure shows a drop-down list containing all of the selectable light color/flash
options.
167
Administrator User Guide
Using the Light to Control the Capture
See also Using the Device Monitor Light - Instructors.
VERY IMPORTANT!! The PC must be on and a user must be logged in for the Device
Monitor to work. While it does run in the background, it does not run as a service
Plan to Adjust the Tension of the Light
There is a screw in the bottom of the light that may need to be loosened in order to
"feel" the light as a button. The light is typically shipped with the screw tightened to
avoid unnecessary movement or loosening during shipment. The button feature does
not have to feel like a button in order to work, but some users may be bothered by the
lack of obvious movement when they press the light.
The Device Monitor light functions not only as a capture status indicator, but also as an
"Easy Button" to start, pause, and stop ad hoc captures. Note that this feature can be
disabled in the Device Monitor Configuration. It is enabled by default.
Whenever the light is used to initiate a capture, the settings configured for the light are
used to define the title, duration, and inputs for the capture, as well as the section to
which it will be published (if configured).
The light will control captures as follows:




To Start an adhoc capture: Press and hold the light for two seconds or until it turns
yellow. The device will turn Red when recording begins.
To Pause a Capture: Tap or press the light briefly; it will flash yellow to indicate a
paused capture.
To Resume a paused Capture: Tap or press the light briefly; it will turn red again to
indicate the capture has resumed.
To Stop a Capture: Press and hold the light for two seconds or until it begins to
flash green. When the capture processing is complete, the light will turn off.
PLEASE NOTE:




The "light indicators" listed above are based on the default Device Monitor
Configuration settings. If you changed these settings, apply those changes to
the above instructions.
If you changed the default LED configurations, communicate those specifics to
the instructors.
You can use the device monitor light to Pause, Resume, and Stop any capture
(scheduled or ad hoc), as well as initiate a new ad hoc capture. As an admin,
you can also turn these control features off.
You cannot Extend a Capture using the light. You must use the System Tray
menu. See the instructions that follow.
To Extend a capture already in progress (either ad hoc or scheduled) with the device
monitor, you must use the System Tray menu. Be advised, however, that if there is a
168
Administrator User Guide
subsequent capture scheduled for the room, you cannot extend the current capture
beyond the starting time of the next scheduled capture for that room.
To Extend a Capture:
1. Open the System Tray menu and select Extend Capture.
2. Enter the amount of time you want to extend the current capture. This duration is
added to the existing capture. For example, if the original duration was set to 45
minutes, enter 15 into this dialog box to make the capture 1 hour.
3. When finished, click OK.
The capture will continue for the configured extension or until you manually stop the
capture.
System Tray Menu Capture Control Can Be Used In Lieu of Light
The above instructions for Extending a capture can also be used to Start, Pause,
Resume, and Stop a capture if you prefer to use the System Tray menu or if pressing the
Device Monitor light does not work.
169
Administrator User Guide
Locking the Configuration
Use the Configuration Lock option to set a password on the Device Monitor
configuration. Locking the configuration is optional.
Select Configuration Lock from the System Tray menu to bring up the Configuration
Security dialog box as shown.
If you do lock the configuration, making any changes to the device monitor
configuration will require entering the appropriate password to do so.
170
Administrator User Guide
Device Monitor Admin Override
Device Monitor 1.9.4 includes an admin override feature that supersedes any local
settings and uses configuration values from a supplied XML file. This allows for mass
deployment of the application without the need to configure each individual instance.
When an admin override XML is used, Device Monitor will parse it, use the supplied
settings and prevent any configuration changes through the user interface. This
includes graying-out the appropriate fields in the Echo360 Configuration window and
preventing access to the Device Monitor Configuration window.
Applying admin override settings
Once you apply the adminOverride.xml file, you will need to restart the Device Monitor
application to apply the settings.
In addition, if your override file configures the device login as well as the device URL,
the password you use in the file must be encrypted. The Device Monitor software
provides an encryption mechanism for you. See encryption instructions below.
To configure the Device Monitor via XML file:
1. Generate an adminOverride.xml file using the example shown below.
2. Replace the values with your configuration settings. If you are using
username/password values in the file, see the password encryption instructions
immediately below.
3. Save the file to the following directory (the directory is created on Device
Monitor installation, so you must have installed the DM software first):
C:\Program Files (x86)\Echo360\Echo360 Device Monitor\
4. Stop and restart the Device Monitor application (select Close Device Monitor
from the System Tray menu, then manually launch Device Monitor from the Start
menu.
To encrypt the password:
1. Open the bundled encryption utility called EchoCryptHelper located in the
following directory:
C:\Program Files (x86)\Echo360\Echo360 Device Monitor
2. Enter the password you wish to encrypt and click Encrypt.
3. Copy the resulting value from the Encrypted Output field and paste it as the
EchoEncryptedPassword value in the adminOverride.xml file.
4. When finished, click Close.
171
Administrator User Guide
Example adminOverride.xml file
An example adminOverride.xml which outlines the required structure is as follows:
<AdminOverride xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<!-- these can be set or not regardless of the
OverrideDelcomSettings flag -->
<EchoServerURI>https://10.3.6.164:8443</EchoServerURI>
<EchoUsername>instructor</EchoUsername>
<EchoEncryptedPassword>166125033209225163193094161087240006163200008
085</EchoEncryptedPassword>
<!-- set to true to enable all of the settings below -->
<OverrideDelcomSettings>true</OverrideDelcomSettings>
<!--disable all delcom light gestures -->
<DisableDelcomGestures>false</DisableDelcomGestures>
<!-- disable individual gestures, if DisableDelcomGestures is true
all will be disabled regardless of these settings -->
<DisableDelcomGestureStart>false</DisableDelcomGestureStart>
<DisableDelcomGestureStop>false</DisableDelcomGestureStop>
<DisableDelcomGesturePause>false</DisableDelcomGesturePause>
<DisableDelcomGestureResume>false</DisableDelcomGestureResume>
<!-- set led sequence and level for each device state -->
<LEDStateIdle>2</LEDStateIdle>
<LEDStateIdlePowerLevel>50</LEDStateIdlePowerLevel>
<LEDStateWaiting>6</LEDStateWaiting>
<LEDStateWaitingPowerLevel>50</LEDStateWaitingPowerLevel>
<LEDStateCapturing>4</LEDStateCapturing>
<LEDStateCapturingPowerLevel>50</LEDStateCapturingPowerLevel>
<LEDStatePaused>7</LEDStatePaused>
<LEDStatePausedPowerLevel>50</LEDStatePausedPowerLevel>
<LEDStateCompleting>3</LEDStateCompleting>
<LEDStateCompletingPowerLevel>50</LEDStateCompletingPowerLevel>
<LEDStateError>5</LEDStateError>
<LEDStateErrorPowerLevel>50</LEDStateErrorPowerLevel>
<!-- allow warning signal when audio is not detected for the delay
time -->
<AudioWarningEnabled>false</AudioWarningEnabled>
<AudioWarningDelay>2</AudioWarningDelay>
<AudioWarningLEDState>13</AudioWarningLEDState>
<AudioWarningPowerLevel>50</AudioWarningPowerLevel>
<!-- allow warning signal when capture is about to end within delay
time -->
172
Administrator User Guide
<CaptureWarningEnabled>false</CaptureWarningEnabled>
<CaptureWarningDelay>5</CaptureWarningDelay>
<CaptureWarningLEDState>8</CaptureWarningLEDState>
<CaptureWarningPowerLevel>50</CaptureWarningPowerLevel>
</AdminOverride>
The two primary tags that dictate the level of override are the EchoServerURI and
OverrideDelcomSettings tags:

The EchoServerURI tag is populated with the URL of the SCHD appliance you
want the Device Monitor to connect to. In addition, you can identify the default
login information for the Device Monitor to use for any adhoc captures initiated
using the light.
With this tag present and ONLY the device URL identified, the Device Url field in
the Echo360 Configuration window will not be editable. However, the Username
and Password fields will still be available.
With this tag present and populated with the URL, Username, and Password, none
of the fields in the Echo360 Configuration window are editable and the option will
be grayed out in the System Tray menu.

Setting the OverrideDelcomSettings tag to true forces the application to use the
Delcom light configuration settings/values directly from the XML file, and disables
the configuration option from the interface (system tray menu, as shown below).
173
Administrator User Guide
Both of these tags can be defined, but at least one must be present for the application
to correctly parse the XML file.
Additionally, the Delcom light settings in the override XML directly reflect the settings
available in the interface and use an integer to map the light configuration. This
mapping is shown in the table below:
Integer
Light Configuration
1
Lights Off
2
Green Light
3
Green Light Flashing
4
Red Light
5
Red Light Flashing
6
Yellow Light
7
Yellow Light Flashing
8
Green Solid/Yellow Light Flashing
9
Green Solid/Red Light Flashing
10
Yellow Solid/Green Light Flashing
11
Yellow Solid/Red Light Flashing
12
Red Solid/Green Light Flashing
13
Red Solid/Yellow Light Flashing
14
Green Solid/Yellow Solid
15
Green Solid/Red Solid
16
Yellow Solid/Red Solid
17
Green Solid/Yellow Solid/Red Solid
174