IP65-30W Microwave Sensor Lamp Instruction
Product size
L:1274mm W:90mm H:90mm
LF:900MM
Packing list in
Ceiling Mount Lamp
LEDS 96PCS
Quantity 1X
Φ6 Plastic expansion
2X
4x30 Screw
2X
Metal hook Metal buckle Seal ring
2X 2X 2X
IP 65
Summary
This is a microwave sensor switches controlled LED lights,the microwave sensor was built into the lamp ,it has 96pcs high brightness LEDs inside ,with total power of 30 watts, the microwave sensor switch is a new type automatic switch that comes after voice switch ,and infrared sensor switch .The detection way has the below advantages compared with other as follows:
1. non-contact detection, 2. Suitable for bad environment, immune to temperature, humidity, noise, air, dust, light…3.RF interference ability, 4.
Transmission power only 0.2 mW, It will not harm the human body. Simple installation+ easy wiring.
We adopt this sensitive advanced sensor switchs in lighting control, enabling the light to turn on automatically when one comes , automatically turn off when one goes out .It is widely applied in the subway sation,tunnel and so forth.
The built-in microwave sensor switch can penetrate plastic, glass, wood . So it can be installed in glass or plastic shell lamp
This allows the application of microwave sensor switch in different styles of lights for energy control. Now, we can provide a variety of microwave sensor LED lamps to meet the needs of different people with different preferences.
Use high quality PC lampshade.Strengthen the flexible refraction of light.And its function of anti-ultraviolet makes the shade not easy to turn yellow and be broken.
LED lamps than incandescent bulbs province electricity 80%;fluorescent lamps province electricity than 50%
Specifications
Power source: 100-240V/AC
Power frequency: 50/60Hz
Rated load: 30W Max.
HF system: 5.8GHz CW electric wave, ISM wave band
Transmission power: <0.2mW
Time setting: 8sec to 12min (adjustable)
Detection range: 1-8m (radii.)(adjustable)
Light-control: 10-2000LUX(adjustable)
Sensor information
Standby power: <0.9W
Detection angle: 360°
Luminous flux: 2400lm
Installation height: 3-6m (ceiling mount)
Lamp part
LED quanlity: 96PCS
LED specifications: T5630
360º
Max:8m Min:1m Min:1m Max:8m
Height of installation3~6M Sensing distance adjustment range Sensing angle adjustment range
Turn the knobs to the ideal conditions
1-8m 8sec-12min 10-2000LUX
Detection range setting (sensitivity)
Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 2.5m, turn the detection range control fully anti-clockwise to select minimum detection range(approx.1m radii), and fully clockwise to select maximum detection range(approx. 8m radii).
1-8m
NOTE: the above detection range is gained in the case of a person who is between 1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature, figure and moving speed change, the detection range will also change.
In different cases, the sensitivity of the lights has certain deviation.
ATTENTION:
When use this product, please adjust the sensitivity to an appropriate position you need, please do not adjust the sensitivity to maximum, to avoid the product does not work normally caused by wrong motion.Because the sensitivity is too high easily detect the wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by interference of power grid & electrical equipment. All those lead the product does not work normally !
When the product does not work normally, please try to lower the sensitivity appropriately, and then test it.
Time setting
The light can be set to stay ON for any period of time between approx.
8sec(turn fully anti-clockwise) and a maximum of 12min(turn fully clockwise).
Any movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for adjusting the detection zone and for performing the walk test.
8sec-12min
NOTE: After the light switches OFF, it takes approx. 1sec before it is able to start detecting movement again. The light will only switch on in response to movement once this period has elapsed.
Light-control setting
10-2000LUX
The chosen light response threshold can be infinitely from approx. 10-2000lux.
Turn it fully anti-clockwise to select dusk- to-dawn operation at about 10 lux.
Turn it fully clockwise to select daylight operation at about 2000lux. The knob must be turned fully clockwise when adjusting the detection zone and performing the walk test in daylight.
Note: Please don’t adjust the three functional buttons to excess. That is because the three functional buttons were connected to the components directly, there is a small stopper in each of the three components, when you adjust the buttons from start to end, the excessive turn will damage the stopper , and lead to the 360°non-stop turn around. The adjust range limit is 270°, please do pay attention to this.
Connection-wire digram
N
L
Fault and the solution
Fault
Does not work with the load
Work all the time with the load
Failure cause
Light-illumination set incorrectly, the load is broken
The power is off
There is a continuous signal in the region of the detection
The sensor have not been installed correctly
Solution
Adjust the setting of the load
Change the load
Turn the power on
Check the settings of the detection area
When there is no a moving signal work with the load
Sensors failed to pack good cause its cannot reliably detect signal
Moving signal is detected by the sensor (movement behind the wall, the movement of small objects, etc.)
When there is a moving signal work with the load
The moving body is too fast or the detection area is too small
Re-install the outer covering
Check the settings of the detection area
Check the settings of the detection area
Note:
the high-frequency output of this sensor is<0.2mW- that is just one 5000 of the transmission power of a mobile phone or the output of a microwave oven.
th
Transmission power: <0.2mW
Induction of human movement
Since entering lighting condition
Application
Warning!
1 .The LED S in serial can function when all the seals installed in place.
2 .Please don’t remove or connect with other lamp when powered on.
3 .When the LEDS in serial are damaged ,you need e x perienced technician to repair using the same rating LED S.
●Please confirm with profession installation.
●For safety purposes, please cut off power before installation and removal operations.
●Improper operation caused losses, the manufacturer does not undertake any responsibility.
We are committed to promoting the product quality and reliability, however, all the electronic components have certain probabilities to become ineffective, which will cause some troubles.
When designing, we have paid attention to redundant designs and adopted safety quota to avoid any troubles.
This instruction, without our permission, should not be copied for any other purposes.