TG1Express w/Ademco Vista 15/20P (Standard Wiring)

TG1Express w/Ademco Vista 15/20P (Standard Wiring)
TG1Express w/Ademco Vista 15/20P (Standard Wiring)
STC Trip Gnd Pwr
Vista 20P Only
* This example of Standard wiring shows an example of a unit powered up using the S.L.I.C. option and with a connection to Zone 1 as a TG
supervisory Zone.
TG1Express w/Ademco Vista 15/20P (Interactive Services Wiring)
STC Trip Gnd Pwr
Vista 20P Only
* This example of Interactive Services wiring shows an example of a unit powered up through the terminal block, and using zone 1 as the
keyswitch and Output 18 as the Arm status zone.
TG1Express w/Ademco Vista 15P (Interactive Services Panel Programming)
PROMPT
ENTER ON KEYPAD
COMMENTS
-
4112 800
Enter Programming Mode (disarm state only)
PROGRAM KEYSWITCH
Set to Confirm?
0=NO 1=YES
Enter zn num
00=quit 01
ZN ZT P RC HW:RT
01 00 1 00 EL:1
ZN T
ZN ZT P RC HW:RT
01 77 1 00 EL:1
*56
Zone Programming Menu Mode.
*
Get to Zone area.
01*
Zone number. In this case, Zone 1 is being used.
*
Enters ZONE TYPE.
77*
Configure zone type for KEYSWITCH.
*00
Get out of zone programming.
PROGRAM OUTPUTS
Enter * or #
OUTPUT FUNCT #
00=QUIT 0X
01 A E P TRIG
?00 0 0 - ZN=00
01 Enter Zn Type
Keysw xx
01 Partition
x
Enter output No.
Txx
x
*80
Output Programming Menu mode.
01*
Output function number XX (01-12).
*2
Activate output by zone type.
*78
Zone type = 78 (could be 78 or 79, 78= red LED, 79= green LED).
1*
Type in partition.
17*
Output number (17 or 18 are the choices)
TG1Express w/Ademco Vista 15P (Interactive Services Panel Programming)
PROMPT
ENTER ON KEYPAD
COMMENTS
*00
To exit the programming menu.
01 A E P TRIG
T17 - - 1 ZT=78
PROGRAM ALARM REPORTING FORMAT
Enter * or #
Rep Form Pri/Sec
XX
*48
Report Format (Primary/Secondary)
77
4 digits ADEMCO CONTACT ID REPORTING primary/secondary.
PROGRAM OPEN/CLOSE REPORTS
*65
OPEN Report 1 2 3
111
Awy/Sty Rp 1 2 3
*66
Awy/Sty Rp 1 2 3
111111
Open report Code.
Arm Away/Stay Rpt. Code.
*99
Exit commands.
Enter * or #
*84
Away stay arm.
Auto Sty Opt
0
NO
*99
Exit Programming Mode.