5991-3904EN
Keysight Technologies
Ininiium S-Series
High-Deinition Oscilloscopes
Data Sheet
The New Standard for
Superior Measurements
02 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Welcome to the Next Generation of Oscilloscope Technology
Ininiium S-Series oscilloscopes incorporate innovative technology designed to deliver
superior measurements.
Our new 10-bit ADC and low-noise front-end technology work together to provide
up to 8 GHz performance with the industry’s best signal integrity. We put these in an
advanced frame with a solid state drive for fast boot-up, capacitive 15” display for easy
touch capability, and a high-powered motherboard for fast processing. It’s all compatible
with a myriad of Keysight Technologies, Inc. probes and Ininiium applications.
There is no better way to experience
that superiority of the Infiniium S-Series
oscilloscopes than to use one.
Contact Keysight today to request a
demo.
Or visit,
www.keysight.com/find/S-Series
The Ininiium S-Series offers bandwidths from 500 MHz up to 8 GHz. Each model, equipped with a large 15” XGA capacitive
touch screen, comes in a quiet package that is just 9” (23 cm) deep.
Scope channels
DSO models
4 scope
channels
MSO models
4 scope channels
+ 16 digital channels
Analog
bandwidth
DSOS054A
MSOS054A
500 MHz
DSOS104A
MSOS104A
1 GHz
DSOS204A
MSOS204A
2 GHz
DSOS254A
MSOS254A
2.5 GHz
DSOS404A
MSOS404A
4 GHz
DSOS604A
MSOS604A
6 GHz*
DSOS804A
MSOS804A
8 GHz*
Max
sample rate
ADC
bits
Standard
memory depth
User-installed
bandwidth upgrades
20 GSa/s (2 channels)
10 GSa/s (4 channels)
10
100 Mpts (2 channels)
50 Mpts (4 channels)
Yes
* 6 GHz and 8 GHz bandwidth supported in 2-channel mode. If all four channels are on, a maximum bandwidth of 4 GHz is supported.
03 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
The New Standard for Superior Measurements
Industry’s best signal integrity
– 10-bit ADC up to 8 GHz for additional vertical resolution
– Low-noise front end for precision signal viewing
– Only 90 uV noise at 1 mV/div and 1 GHz bandwidth
– System ENOB values in excess of 8
– SFDR values down to –73 dBC
– 2 mV/div vertical scaling supported in hardware
– HW bandwidth limit ilters on both 50 Ω and 1MΩ paths
– Correction ilters ensure lat frequency magnitude and phase response
– Low intrinsic jitter (100 fs (typical) for excellent jitter characterization)
– Precision BNCs with > 8 GHz bandwidth
Most advanced platform
– Powerful, lexible Ininiium user interface
– Capacitive touch screen with multi-touch, easy-grab handles, and re-sizing touch
ields
– Powerful Intel i5 motherboard with 8 GB RAM for fast processing
– Removable solid state drive (SSD) for fast boot-up and increased reliability
and security
– Fast data ofload (up to 200 MB/s) via USB 3.0
Broadest range of capability
– 16 digital channels on MSO models
– Standard feature rich software with > 50 automated measurements,
16 math functions, gating, and spectral viewer
– Expandable with optional software applications and
lexible licensing:
– Add protocol decode and triggering for a wide variety of serial buses
– Choose from a large selection of analysis applications including eye diagrams
and measurements with SDA, jitter, IniniiScan, and de-embedding
– Test to ensure adherence to industry standards with compliance apps
– Support for > 100 probes – current and voltage, active and passive,
1 MΩ and 50 Ω inputs
04 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Industry’s Best Signal Integrity
S-Series next-generation technology blocks enable superior measurements
The heart of the oscilloscope is a 20-layer acquisition board with 16 custom ASICs and FPGAs. New technology blocks deliver superior
signal integrity. You’ll get superior measurements that you won’t get with any other portable scope on the market.
10-bit ADC
Each model incorporates the industry’s fastest 10-bit ADC with a sample rate of
40 GSa/s. This yields 2 channels at 20 GSa/s or 4 channels at 10 GSa/s.
– 4X more vertical resolution than 8-bit oscilloscopes
– ADC ENOB up to 8.7 contributes to high system ENOB values
– Up to 12 bits of resolution with high-res mode
– SNR are better than historical 8-bit ADC architectures
– Vertical scaling as low as 2 mV/div supported in hardware
Keysight’s new 10-bit ADC
– 65 nm CMOS (9 mm x 14 mm)
– 130 nm BiCMOS buffer IC
– Custom 33 mm BGA package
Superior low-noise front end
– 10-bit ADC’s usefulness is dependent on the low-noise front end that supports the
additional quantization levels. Each S-Series oscilloscope incorporates the industry’s
lowest noise front end for portable
oscilloscopes with bandwidth up to 8 GHz
– 50 Ohm and 1 MΩ input support, each path with bandwidth limit ilter support
– Analog and DSP bandwidth limit ilters to reduce unwanted noise
– 90 uV noise at 1 GHz bandwidth allows viewing of small signal detail
– 2 mV/div vertical scaling in hardware (in combination with ADC)
– HW bandwidth limit ilters on both 50 Ω and 1MΩ paths
– Gold-plated precision BNCs rated in excess of 8 GHz bandwidth
– Electronic attenuators for decreased noise and increased reliability
– Lower bandwidth models are upgradable to any higher bandwidth model with an
instant user-installed software license
S-Series front-end includes three new custom ICs
including a 130 nm BiiCMOS IC that incorporates
user-selectable analog ilters and bandwidth
upgrades via a software license.
05 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Industry’s Best Signal Integrity
S-Series next-generation technology blocks enable superior measurements
Superior time base
Time scale accuracy is critical, especially for deep-memory
applications.
Measurement of jitter is necessary for ensuring high-speed system
reliability. Intrinsic jitter associated with an oscilloscope includes
the jitter measurement internal to the scope. The lower the value,
the better you’ll be able to characterize your device. S-Series scopes
achieve precise time accuracy with a next-generation time base
architecture.
– Best-in-industry time scale accuracy of 12 parts per billion after
calibration for accurate deep-memory measurements
– Low jitter measurement loor with 100 fs (typical) of intrinsic jitter
Signal processing in hardware
S-Series oscilloscopes are built with an advanced FPGA dedicated
for fast and precise signal processing. The technology produces the
fastest deep memory responsiveness in the industry and provides
additional hardware iltering for superior measurements.
– Hardware-based algorithms for accelerated drawing to display
(pixel placement) enable fast pan and zoom even with deep
memory
– Frequency-response correction ilters produce lat responses
for both magnitude and phase for more accurate waveforms
– User-selectable hardware bandwidth-limiting ilters from 500 MHz
up to the oscilloscope’s bandwidth reduce unwanted noise
– Supports cabled 2-channel differential inputs (channels 1-3 or
channels 2-4) without requiring a differential probe
– The DSP technology block supports rapid optional de-embedding
technologies such as IniniiSim, Precision Probe, and equalization
Responsive deep memory
S-Series oscilloscopes come with the industry’s most responsive
deep memory. With standard 50 Mpts/channel on all four channels
simultaneously, capture long time periods while retaining fast
sample rates. Fast update rates mean your oscilloscope will stay
responsive with deep memory on to ensure precise representation
of analog signals.
06 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Most Advanced Platform
S-Series next-generation technology enables superior measurements
S-Series platform standard features
250 GB removable SSD
– Fast boot up
– Increased reliability
– Easy to remove for secure environments
Powerful motherboard
– 3 GHz Intel i5 quad core processor with 8 GB RAM for fast
computations — even with advanced math and deep memory
– IO
– Ethernet 10/100/1000bT
– 6 USB device ports (2 in front, 4 on side two of which are USB 3.0)
– DisplayPort and VGA video out. Drivers support up to two simultaneous displays
Fast data ofload
Have an application that requires programmatically accessing oscilloscope data?
– USB 3.0 for up to 200 MB/s ofload
– 1000bT Ethernet for up to 80 MB/s ofload
Touch-screen innovation
S-Series oscilloscopes incorporate a capacitive touch screen. In
addition, Ininiium software includes a large number of touchfriendly enhancements including handles, enlarged touch ields
when touch is enabled, and gestures (multi-touch).
Fast
ofload
07 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview
With up to 8 GHz bandwidth, 20 GSa/s
sample rate, a 10-bit ADC, and a low-noise
front-end, see a precise representation of the
analog characteristics of the signals you’re
testing.
Noise directly impacts vertical placement of each signal point.
Oscillocopes with lower noise have more accurate vertical placement. S-Series oscilloscopes incorporate next-generation technology to deliver the lowest noise measurements in the industry.
Here’s a compare at 4 GHz with 5 mV/div scaling.
Superior signal integrity allows for more accurate measurements
such as rise time values. Extremely low intrinsic jitter (100 fs)
ensures the lowest possible contribution to jitter measurements
from the scope itself so you’re using your jitter budget on your
design.
08 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview – Time Domain
Display windows and scale annotations
Both horizontal and vertical axis values are annotated on the
scales, leading to fast interpretation. Ininiium oscilloscopes
uniquely offer 16 grids per waveform area, with up to 8 waveform
areas.
Results window
See up to 20 measurement results simultaneously with statistics.
Each result is color-coded to the source. Turn on measurement
annotations for additional documentation capability.
Math and measurements
With > 50 standard automated measurements with statistics and
16 independent math functions, you’ll be able to analyze a wide
variety of tests. Use any of the industry-best 16 independent
gates to narrow measurements or math to a speciic time window.
09 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview – Frequency Domain
With a built-in spectral viewer, controls, gated FFTs, 10-bit ADCs, and excellent SFDR values, the S-Series oscilloscopes provide an
excellent scope platform for FFT measurements.
FFTs
Need to see frequency domain in additional to time domain? The
standard spectral viewer includes FFT controls like start/stop
RBW and CF/span. Readout includes power and frequency axis
annotation and a peak table.
Gated FFTs
Ininiium supports gated math and analysis including FFTs.
Use any of the standard 16 independent gates to narrow FFT
computations to a speciic time window. Drag the gate in the time
domain, and see time correlated FFT measurements for speciied
time periods. The example at the right shows two simultaneously
FFTs.
Envelope measurements
Need to see the rise time of a burst? Add a rise time measurement
to an envelope function that provides an AM demodulation of a
burst.
10 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview - Frequency Domain
Wideband and multi-channel FFTs
Need to see >500 MHz signal spectral bandwidth and/or multiple FFTs simultaneously? Oscilloscopes offer wider bandwidth than
spectrum analyzers and come standard with four ports (channels) per instrument.
1
0 MHz
BW
PXA
UXA
160 MHz
510 MHz
160 MHz
BW
510 MHz
BW
8 GHz
BW
Z-Series
S-Series
V-Series
90000A Series
Up to 4
Number of channels
Ininiium S-Series enables users to make wideband measurements up to 8 GHz and up to 16 simultaneous FFTs. Analyze even higher
bandwidth signals by combining with a down converter.
13 GHz
BW
32 GHz
BW
RF signal spectral bandwidth
Use Ininiium capture and analysis of radar bursts, as
shown in this OFDM example.
Use Ininiium capture and analysis of radar bursts, as
shown in this OFDM example.
… 63 GHz
BW
11 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview - Frequency Domain
Trying to interpret traditional oscilloscope time-domain speciications can be challenging in determining if a speciic scope can
be recommended for RF/uW/mmW measurements. With correction ilters, low-noise front end, and the 10-bit ADC, S-Series
oscilloscopes can be used for wideband RF applications. Typical RF characteristics for the S-Series are listed below with graphs
showing characterization results shown at the bottom of the page.
Typical RF characteristic values from measured results on an 8-GHz S-Series oscilloscope
Sensitivity / noise density (1 mV/div; -38 dBm range)
Power spectral density measurement at 1.0001 GHz, 1.0001 GHz center frequency,
500 kHz span, and 3 kHz RBW
-160 dBm/Hz
Noise igure (derived from measurement above)
14 dB
Signal-to-noise ratio / dynamic range (0 dBm 1 GHz input carrier, 0 dBm scope input range)
1 GHz center frequency, 100 MHz span, 1 kHz RBW, measurement at +20 MHz from center
108 dB
Absolute amplitude accuracy (0 to 7.5 GHz)
± 1 dB
Deviation from linear phase (0 to 7.5 GHz)
± 7 deg
Phase noise (at 1 GHz)
10 KHz offset
100 KHz offset
-121 dBc/Hz
-122 dBc/Hz
EVM (802.121 2.4 GHz carrier, 20 MHz wide, 64 QAM)
-47 dB (0.47%)
Spurious responses (0 dBm signal, 0 dBm input range)
Spur Free Dynamic Range (SFDR)
1 GHz, 0 dBm signal present at input, FFT =5 GHz span, 3 GHz center, 100 kHz RBW
72 dB
2nd harmonic distortion
1 GHz input, 0 dBm, 5 GHz span, 3 GHz center, 100 KHz RBW
-64 dBc
3rd harmonic distortion
1 GHz input, 0 dBm, 5 GHz span, 3 GHz center, 100 KHz RBW
-46 dBc
Two-tone Third-Order Intermodulation (TOI) distortion
0 dBm input tones, 2.435 GHz and 2.439 GHz, 2 MHz separation, 2.437 GHz center frequency, 10 MHz span,
100 kHz RBW, 6 dBm input range
Input match
(< 50 mV/div, 0-7 GHz)
(>= 50 mV/div, 0-7 GHz)
Using data acquired from S-Series, VSA shows an
excellent TOI value of 21.5 dB.
+21.5 dB
-15 dB; 1.4 VSWR
-19 dB; 1.25 VSWR
Using data acquired from S-Series, VSA shows an
EVM for IEEE 802.11 QAM 64 of 0.47%.
12 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Oscilloscope Overview – User Interface
Ininiium oscilloscopes have been consistently recognized for high usability. The next-generation Ininiium user interface that ships
standard on S-Series oscilloscopes delivers even more capability.
Personalized viewing
– Determine how much space to give to results versus
waveforms using sliders
– Undock and move a window to an external monitor using the
tabbed layout
– Easily scale and see independent waveforms with
user-selectable 1, 2, 4, or even 16 simultaneous grids in each
waveform area
Faster and better documentation
– Quickly determine horizontal and vertical values as they are
prominently displayed
– Add annotations using bookmarks, measurement
callouts, and dynamic delta marker readouts
– Right-click to copy image without ever having to save to a ile
– Use the multi-purpose button to save screen images easily
with auto-incrementing ile names
– Quickly save all waveforms, memories, functions, and setups
in a single .osc ile for later recall on an
oscilloscope or PC
– Save screen images as .jpg, .png, .gif, or .tiff
Best usability, including touch screen
Extensive research testing led to several touch-screen
innovations not found in other oscilloscopes. All the
following are industry irsts.
– Click once to see handles that enable touch
manipulation of markers, trigger level, and
waveform-tasks that previously required a mouse
– Multi-touch support for multi-touch (gestures) such as zooming and panning
– Auto-sizing when touch button is turned on/off
optimizes ields for ingers or a mouse
13 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Using an External Monitor
Undock and move a window to an external monitor using tabbed
layout.
S-Series supports both VGA and DisplayPort IO.
Ininiium Ofline Application
View and analyze results at your desk. Save your oscilloscope ile,
then view and analyze on your PC without needing additional access to your scope.
Use waveform math, iltering, and FFT spectral analysis and to
get more insight. Need to see protocol decode, analyze jitter, or
view eye diagrams? Ininiium Ofline helps you get insight into all
of these areas.
14 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
MSO Overview
MSO models add 16 high-speed timing channels with standard 128 Mpts digital memory, allowing you to retain fast 2 GSa/s sample
rates over long periods of time. All DSOs are user-upgradable to MSOs. The required upgrade time is less than 5 minutes.
Use the digital channels to evaluate control signal relationships
and data buses up to 16 bits wide. Use symbols to quickly
interpret waveforms.
MSO measurement applications
– Trigger on and view speciic control
or data low events
– Use digital channels for protocol
trigger and decode (I²C, SPI, RS-232, JTAG, USB and more)
– Capture data from FPGA debug ports
– Trigger on and monitor power rail
sequencing timing relationships
– Combine with oscilloscope channels
to trigger across up to 20 channels
simultaneously
15 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Protocol Applications
Does your design include a serial bus that is a key point for debug or test? Use one of Keysight’s protocol decoding and
triggering application packages for increased productivity. The software converts DSO or MSO physical layer acquisitions into
packets for speciic protocols. Specify trigger conditions at the packet level.
Quickly move between physical and protocol layer information
using the time-correlated tracking marker. Display protocol
content in waveforms and/or listing.
License type
Optional application description
Fixed
Floating
Factory-installed on new
scope purchase or userinstalled on existing scope
User-installed
transportable license
Server-based license
(N5435A option)
Protocol
8B/10B
N5384A-1FP
N5384A-1TP
003
CAN, LIN, FlexRay protocol decode and triggering
N8803B-1FP
N8803B-1TP
033
DVI
N5384A-1FP
N5384A-1TP
003
HDMI
N5384A-1FP
N5384A-1TP
003
I²C, SPI, and RS-232/UART protocol decode and triggering
N8800B-1FP
N8800B-1TP
n/a
I²C/SPI protocol decode
N5391B-1FP
N5391B-1TP
006
JTAG protocol decode
N8817B-1FP
N8817B-1TP
038
MIPI® CSI-3 (M-PHY®) protocol decode
N8820B-1FP
N8820B-1TP
n/a
MIPI DigRF v4
N8807B-1FP
N8807B-1TP
047
MIPI D-PHY™ protocol decode
N8802B-1FP
N8802B-1TP
036
MIPI LLI protocol decode
N8809B-1FP
N8809B-1TP
049
MIPI RFFE protocol decode
N8824B-1FP
N8824B-1TP
072
MIPI UniPro protocol decode
N8808B-1FP
N8808B-1TP
048
PCI Express® Gen1 and Gen2 protocol decode and triggering
N5463B-1FP
N5463B-1TP
032
RS-232/UART protocol decode and triggering
N5462B-1FP
N5462B-1TP
001
SATA/SAS protocol decode
N8801A-1FP
N8801A-1TP
035
SVID protocol decode
N8812B-1FP
N8812B-1TP
054
USB 2.0 protocol decode and triggering
N5464B-1FP
N5464B-1TP
034
USB 3.0 protocol decode
N8805B-1FP
N8805B-1TP
n/a
USB 3.0 SuperSpeed Inter-Chip (SSIC) protocol decode
N8819B-1FP
N8819B-1TP
n/a
16 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Analysis Applications
A variety of analysis capabilities enable additional rapid insight
IniniiScan
Rapidly trigger on complex events that you can see but are
impossible to specify using hardware triggers. This innovative
software quickly scans through thousands of acquired waveform
cycles and isolated anomalous signal behavior. Select up to eight
zones across scope channels are available.
SDA (Serial Data Analysis)
Quickly validate signal integrity for high-speed serial interfaces
with embedded clocks. Recover embedded clocks, and build and
validate eye diagrams. SDA also includes software-base trigger
and decode for 8B/10B data.
EZJIT, EZJIT Plus, and EZJIT Complete
Characterize and evaluate most commonly needed jitter
measurements. EZJIT Plus automates Rj/Dj separation, and EZJIT
Complete additionally characterizes vertical noise.
See jitter data sheets for additional information.
17 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Other Popular Applications
National Instrument Drivers
LabVIEW Plug and Play and IVI-C drivers for S-Series are available on ni.com/idnet
VSA
Expand your oscilloscope with the 89601B vector signal analysis
software. This application takes data from the scope and provides
spectrum analysis and digital modulation analysis for wireless
communication.
MATLAB integration with UDF
Install MATLAB on your oscilloscope, and add your favorite
.m scripts as math function operators. Export and analyze
oscilloscope data directly with MATLAB. The FFT waterfall
spectrogram on the right is an example of processing that can
be done in MATLAB. Order N8831A with option 001 for MATLAB
Basic or option 002 for MATLAB advanced.
Optional application description
Analysis
DSA (bundle with EZJIT Complete and SDA bundle)
License type
Fixed
Factory-installed on new scope purchase
or user-installed on existing scope
Floating
User-installed
transportable license
Server-based license
(N5435A option)
DSOS000-DSA (new purchase only)
n/a
003 and 055
Equalization emulation
N5461B-1FP
N5461B-1TP
026
EZJIT
E2681B-1FP
E2681B-1TP
002
EZJIT Plus
N5400B-1FP
N5400B-1TP
001
EZJIT Complete vertical noise analysis
N8823B-1FP
N8823B-1TP
067
FPGA dynamic probe for Xilinx FPGAs
N5397A-1FP
N5397A-1TP
n/a
IniniiScan
N5415B-1FP
N5415B-1TP
004
Ininiisim Basic
N5465B-3FP
N5465B-3TP
026
IniniiSim Advanced
N5465B-1FP
N5465B-1TP
027
OSA (Oscilloscope Signal Analyzer)
W2650A
n/a
n/a
Power
U1882B-1FP
U1882B-1TP
n/a
PrecisionProbe
N2808A-1FP
N2808A-1TP
044
Serial data analysis
N5384A-1FP
N5384A-1TP
003
UDF (user-deined function for MATLAB integration)
N5430B-1FP
N5430B-1TP
005
18 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Standard Features
15” XGA display makes it easier to view analog and digital
signals as well as spectral and protocol views
Capacitive display makes for responsive touch control and
supports multi-touch gestures
View: Up to 8 waveforms areas. Each area can have up
to 16 grids
Drag and drop enables rapid measurements
Measurements
Over 50 automated measurements
View up to 20 simultaneously
User-customizable result window
(size, position, and information)
X and Y markers with dynamic delta values
Analyze
20 math operators including FFT and ilters
Up to 16 independent/cascaded math functions
View windows: Analog, math, spectral, and measurement
results (simultaneous, tabbed, or undocked)
Built-in 10-MHz reference in/out ports
synchronizes multiple measurement
instruments in a system
XGA and DisplayPort video output ports
let you add an external monitor
Standard USB 2.0 and 3.0 and LAN ports
provide fast data ofload, device support,
and connectivity
Trig in/out ports provide an easy way to
synchronize your oscilloscope to other
instruments
Mixed-signal oscilloscope (MSO)
models seamlessly integrate four
analog scope channels with 16 digital
channels
19 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Dedicated single acquisition button provides better control
to capture a unique event
Pressing horizontal delay knob sets the delay to zero
Zoom button provides quick access to two screen-zoom
modes
Responsive deep memory allows you to pan and zoom
quickly
Autoscale lets you rapidly display any analog or digital
active signals, automatically setting the vertical, horizontal
and trigger controls for the best display, while optimizing
memory
Digital channel button provides quick setup access
Protocol decode button enables quick setup access
Dedicated per-channel front panel controls make it easy
to access the vertical and horizontal scaling and offset
Quick access to ine/course control by pressing the horizontal and vertical sensitivity knobs
Built-in USB ports makes it easy to save your work and
update your system software quickly.
Gold-plated precision BNCs
deliver > 8 GHz bandwidth
through the connector
AutoProbe interface
automatically conigures the
attenuation ratio of the probe
and provides probe power for
Keysight’s active probes.
20 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Compliance Applications
Need to test adherence to an
industry-standard serial bus?
The S-Series supports many compliance
applications.
License type
Optional application description
Fixed
Floating
Factory-installed
on new scope purchase
or user-installed on
existing scope
User-installed
transportable
license
Server-based
license
(N5435A option)
Compliance (see individual application data sheets for additional information)
Minimum
bandwidth (GHz)
BroadR-Reach
N6467B-1FP
N6467B-1TP
N5435A-062
DDR bundle - includes DDR1, 2, 3 and 4
N5459B-1FP
n/a
n/a
1
DDR1 (200 -1067 MT/s)
U7233B-1FP
U7233B-2FP
N5435A-021
1-4
DDR2 + LPDDR2 (400 - 1067 MT/s)
N5413C-1FP
N5413C-1TP
N5435A-037
2-4
DDR3 + LPDDR3 (800 - 1067 MT/s)
U7231C-1FP
U7231C-1TP
N5435A-053
4
eMMC
N6465B-1FP
N6465B-1TP
N5435A-061
1
Ethernet
N5392C-3FP
N5392C-3TP
N5435A-008
1
Ethernet + EEE
N5392C-1FP
N5392C-1TP
N5435A-060
1
10GBase-T
U7236B-1FP
U7236B-1TP
N5435A-023
2.5
HDMI 1.4
N5399D-3FP
N5399D-3TP
N5435A-011
8
MHL 2.0
N6460C-3FP
N6460C-3TP
N5435A-050
8
MIPI D-PHY
U7238D-1FP
U7238D-1TP
N5435A-022
4
MIPI M-PHY®
U7249D-1FP
U7249D-1TP
N5435A-043
6
MOST
N6466B-1FP
N6466B-1TP
N5435A-068
1.5
PCI Express Gen1
N5393E-3FP
N5393E-3TP
N5435A-040
6
UDA (User-Deined Application)
N5467C-1FP
N5467C-1TP
N5435A-058
0.5
UHS-I
N7246B-1FP
N7246B-1TP
n/a
1
UHS-II
N6461B-1FP
N6461B-1TP
N5435A-052
6
USB 2.0
N5416B-1FP
N5416B-1TP
N5435A-017
2
HSIC
U7248C-1FP
U7248C-1TP
N5435A-042
2
XAUI
N5431B-1FP
N5431B-1TP
N5435A-018
6
Need to additionally test even higher-speed serial buses?
Consider Keysight’s Z-Series, 90000A Series, or 90000 X-Series.
21 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Probes Overview
S-Series oscilloscopes include both 1 MΩ and 50 Ω paths.
This expands their lexibility by making them compatible with a
wider range of probes than high-performance
oscilloscopes that only support a 50 Ω path.
All S-Series oscilloscopes ship standard with four passive probes
and support a wide range of about 100 compatible current and
voltage probes. The table below highlights probes commonly
used with the S-Series.
See http://literature.cdn.keysight.com/litweb/pdf/5968-7141EN.pdf
for additional info on probes andaccessories.
Probe type
Ideal for measuring
Recommended probe model numbers
Passive probe
Single-ended voltage up to 500 MHz
N2873A (qty. 4 ship standard)
IniniiMax active probe
Differential or single-ended voltage
Differential, single-ended or common mode voltage
1130A/31A/32A/34A, 1168A/69A
N2830A/31A/32A (IniniiMode)
IniniiMode active probe
Single-ended, differential, or common mode voltage
N2750A-52A
Single-ended active probe
Single-ended voltage up to 2 GHz
N2795A, N2796A, N2797A (extreme temperature)
General purpose
differential probes
High voltage differential signal up to 7 kV with high CMRR
N2790A, N2791A, N2818A, N2819A, N2891A
Current probe
Passive probes
Power rail probe
High current, AC/DC (mA – 100’s of A)
1146B, 1147B, N2780B-83B, N2893A
High sensitivity current, AC/DC (10’s of uA – A)
N2820A, N2821A
High voltage up to 30 kV peak pulse
10076B, N2771B
General purpose up to 1.5 GHz
N2870A – N2876A
Single-ended up to 2 GHz with up to ± 24 V offset
N7020A
22 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Probes and Accessories Overview
N7020A power rail probe
Do you need more offset than is available in your oscilloscope
frame? Do you need to zoom in to view and analyze small
signals like ripple on top of power rails? Do you need more input
impedance than 50 Ω at DC to make more precise
measurements? If so, the N7020A power rail probe has the
feature set that will help you test more eficiently and precisely.
Developed speciically for power rail testing needs, the probe
delivers 850 mV dynamic range with an impressive offset range
of ± 24 volts. Low noise with a 1:1 attenuation ratio and 2 GHz
bandwidth and low DC loading complements the probes ability to
deliver superior power rail measurements.
Go to www.keysight.com/ind/N7020A for additional information.
N2750A Series IniniiMode active probes
These active probes offer 1.5/3.5/6 GHz bandwidth and
IniniiMode operation modes and provide convenient and quick
access to various functions on the oscilloscope.
With wide dynamic range (10 Vpp at 10:1) and offset range
(± 15 V), these probes can be used for a vast variety of
measurements.
Go to www.keysight.com/ind/IniniiMode for
additional information.
N2820A Series high-sensitivity current probes
Need to measure small currents? The N2820A Series highsensitivity current probes can measure down to 50 uA and up to 5
amps. Combine with the S-Series for lower noise and 10-bit ADC
high-deinition current measurements. This probe can also be
used to measure sensitive low voltages down to 3 uV.
Go to http://www.keysight.com/ind/N2820A for
additional information.
23 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Keysight Portfolio Compare
IniniiVision
Ininiium
Family
6000 X-Series
9000 Series
S-Series
90000A Series
Optimized for
Fastest update rate and
lowest price up to 6 GHz
Measurements
up to 4 GHz
Superior signal integrity
up to 8 GHz
Superior signal integrity
up to 13 GHz
Available bandwidths
500 MHz to 6 GHz
600 MHz to 4 GHz
500 MHz to 8 GHz
2.5 GHz to 13 GHz
Standard memory
depth/ch (2-ch)
4 Mpts
40 Mpts
100 Mpts
40 Mpts
ADC bits
8
8
10
8
Bandwidth ilters
Yes
20 MHz
(only on 1 MΩ input)
Yes. Extensive
Yes. Extensive
Bandwidth correction ilters
No
No
Yes
Yes
Probe inputs
50 Ω and 1 MΩ
50 Ω and 1 MΩ
50 Ω and 1 MΩ
50 Ω
Motherboard and OS
None. Embedded
Intel Core 2 Duo. Win7
Intel i5 Quad-Core. Win7
Intel Core 2 Duo. Win7
Standard internal drive
None
HDD
Removable SSD
HDD
BNC inputs
Traditional
Traditional
Precision BNC
Precision BNC
MSO models
Yes
Yes
Yes
No
Frame volume comparison
1/2 X
X
X
2X
Ininiium S-Series blends high-performance oscilloscope capability with a wide
range general-purpose features.
24 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Accessories
Quickly remove your solid state drive for
additional security.
All S-Series models ship standard with a solid state drive. This
gives you faster boot time, enhanced reliability, and the ability
to quickly remove the solid state drive for safekeeping in secure
environments. Need additional solid state drives for secure environments? N2746S provides an additional solid state drive with
Windows 7.
Need to ship your oscilloscope or take it on an
airplane?
Cruzer has created a custom case for Keysight’s Ininiium
S-Series oscilloscopes. Order the rugged hard-shell transit case directly from Cruzer (http://www.casecruzer.com/
oscilloscope/3f1312-0411j.html) using the product number
3F1312-0411J. Shipping weight with an S-Series frame and no
accessories is 51.5 lbs (23.4 kg).
Rack mount your oscilloscope.
Mount your S-Series oscilloscope in an 8U high, 19” (487 mm)
wide rack with the N2902B rack mount kit. The sturdy kit
provides additional BNCs on the rack mount front panel for BNC
in/out signals on the side of S-Series models.
25 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Take a Quick Look Using Demo Wizard and USB Demo Board
Evaluate using demo wizard waveforms
We’ve captured a variety of signals and measurements to speed
your evaluation of S-Series oscilloscopes. Use the demo wizard to
quickly evaluate the scope’s capability without needing to create
an array of live signals.
Measurement examples
For example, pull up an FFT and note the following: separate
spectral viewer with annotated axis scales; dynamically updated
X and Y marker delta values; a customizable results window that
includes an FFT peak table.
N2867A USB demo board
Plug a mouse, USB drive, or any other device in one side and connect the other to your oscilloscope USB port. You now have easy
access to a target for quick evaluation or training others on how
to use the scope.
The board routes out D+, D-, 5 V, and ground, so you can use it to
make voltage, current, power, or other measurements.
26 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Investment Protection
Expand your oscilloscope’s capability with additional memory, bandwidth, digital channels, or software
applications.
Capture more time and keep faster
sample rates as horizontal settings
are slowed. Additional acquisition
memory can be added to the initial
purchase or after purchase.
All S-Series oscilloscopes ship with
the same hardware and are calibrated
to 8 GHz on the production line. In
less than 1 minute, any lower-bandwidth S-Series scope can be userupgraded to any higher bandwidth.
Acquisition memory depth upgrade
Option # on new scope
N2113A Option #
(for previously
purchased scopes)
Increase to 100 Mpts/200 Mpts (4-ch/2-ch)
DSOS000-100
100
Increase to 200 Mpts/400 Mpts (4-ch/2-ch)
DSOS000-200
200
Increase to 400 Mpts/800 Mpts (4-ch/2-ch)
DSOS000-400
400
Bandwidth upgrades
DSOS8GBW
Upgrade to 8 GHz bandwidth
DSOS6GBW
Upgrade to 6 GHz bandwidth
DSOS4GBW
Upgrade to 4 GHz bandwidth
DSO2G5BW
Upgrade to 2.5 GHz bandwidth
DSOS2GBW
Upgrade to 2 GHz bandwidth
DSOS1GBW
Upgrade to 1 GHz bandwidth
Note: Customer-installable calibration is recommended and incurs additional charges.
Upgrade any DSO model to an MSO
in less than 1 minute with the N2901E
MSO upgrade kit.
27 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
S-Series Ordering Coniguration
S-Series ordering coniguration
Calibration and accessory options
1. Choose needed bandwidth
Standalone PN 54855-67604
2. Choose MSO or DSO
170225 compliant calibration
DSOS000-1A7
3. Choose desired software applications
17025 compliant calibration with accreditation
DSOS000-AMG
4. Choose memory depth upgrade
ANSI Z540 complaint calibration
DSOS000-A6J
5. Choose any additional probes and accessories
S-Series rackmount kit (8U high)
N2902B
Additional SSDs with Win7
N2746S
GPIB to LAN adapter
N4865A
Scope channels
DSO models
4 scope
channels
MSO models
4 scope channels
+ 16 digital channels
Analog
bandwidth
DSOS054A
MSOS054A
500 MHz
DSOS104A
MSOS104A
1 GHz
DSOS204A
MSOS204A
2 GHz
DSOS254A
MSOS254A
2.5 GHz
DSOS404A
MSOS404A
4 GHz
DSOS604A
MSOS604A
6 GHz*
DSOS804A
MSOS804A
8 GHz*
Max
sample rate
ADC
bits
Standard
memory depth
User-installed
bandwidth upgrades
20 GSa/s (2 channels)
10 GSa/s (4 channels)
10
100 Mpts (2 channels)
50 Mpts (4 channels)
Yes
* 6 GHz and 8 GHz bandwidth supported in 2-channel mode. If all four channels are on, a maximum bandwidth of 4 GHz is supported.
** For MSO upgrades, customer-installable calibration is recommended and incurs additional charges.
Standard accessories Included
All models ship standard with: 3-year warranty, four N2873A 500-MHz passive probes, probe accessory pouch,
Keysight I/O libraries suite, localized power cord, front panel cover, 8 GHz BNC calibration cable, keyboard, and mouse.
User guide and programmer’s guide ship on oscilloscope drive. Service guide available on Keysight.com. MSO models additionally ship
with 16-channel lying lead set logic probe, MSO cable, and MSO calibration ixture.
28 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics
Vertical
DSO/MSO models
S-054A
S-104A
S-204A
S-254A
S-404A
S-604A
S-804A
Vertical - scope channels
Input channels
Analog bandwidth (–3 dB)
Vertical
DSO models - 4 analog
MSO models - 4 analog + 16 digital
50 Ω1
500 MHz
1 GHz
2 GHz
2.5 GHz
4 GHz
6 GHz6
8 GHz 6
1 MΩ
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
500 MHz
resolution2,3
10 bits, up to 12 bits with high-resolution mode
Typical rise time/fall time 10
to 90% 4
860 ps
430 ps
215 ps
172 ps
107.5 ps
71.7 ps
53.8 ps
Typical rise time/fall time 20
to 80%5
620 ps
310 ps
155 ps
124 ps
77.5 ps
51.7 ps
33.8 ps
ENOB (typical)
8.1
7.8
7.5
7.4
7.2
6.8
6.4
Input
50 Ω: ± 3.5% (typical ± 1% at 25 °C)
1 MΩ: ± 1% (14 pF typical)
impedance1
Input sensitivity 3
50 Ω: 1 mV/div to 1 V/div
1 MΩ: 1 mV/div to 5 V/div
Input coupling
50 Ω: DC
1 MΩ: AC (> 11 Hz), DC
Bandwidth limit ilters (analog)
20 MHz, 200 MHz for both 50Ω and 1MΩ paths
DSP bandwidth limit ilters
Increments of 500 MHz up to rated scope bandwidth
Channel-to-channel isolation
DC to 100 MHz: 50 dB
100 MHz to 1 GHz: 40 dB
> 1 GHz: 30 dB
DC gain accuracy1,2,3
± 1% of full scale at full resolution (typical 5 mV to 1 V per division)
± 2% of full scale at full resolution1
Max input voltage1
50 Ω: ± 5 V
1 MΩ: 300 Vrms or DC and ± 400 Vpp (DC+AC)
Offset range
1.
2.
3.
4.
5.
6.
50 Ω
1MΩ
Vertical sensitivity
Available offset
Vertical sensitivity
Available offset
All vertical ranges
± 12 divisions or ± 4 V,
whichever is smallest
< 10 mV / div
±2V
≥ 10 mV / div
±5V
≥ 20 mV / div
± 10 V
≥ 100 mV / div
± 20 V
≥ 1 V / div
± 100 V
Denotes warranted speciications, all others are typical. Speciications are valid after a 30-minute warm-up period and ± 5 °C from
irmware calibration temperature. Input impedance is valid when V/div scaling is adjusted to show all waveform vertical values within the
oscilloscope display.
Vertical resolution = 0.4% of full scale.
50 Ω input: Full scale is deined as 8 vertical divisions. Magniication is used below 2 mV/div, full-scale is deined as 16 mV.
The major scale settings are 5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V. Testing is at maximum sample rate.
1 MΩ input: Full scale is deined as 8 vertical divisions. Magniication is used below 2 mV/div, full-scale is deined as 16 mV.
The major scale settings are 5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V. Testing is at maximum sample rate.
Calculation based on Tr = 0.43/BW.
Calculation based on Tr = 0.31/BW.
6 GHz and 8 GHz bandwidth supported in 2-channel mode. If all four channels are on, a maximum bandwidth of 4 GHz is supported.
29 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Vertical
Offset accuracy1,3
± 0.1 div ± 2 mV ± 1% of offset setting for offsets < 2 V
± 0.1 div ± 2 mV ± 1.5% of offset setting for offsets ≥ 2 V
Dynamic range4
50 Ω: ± 4 divisions from center screen
1 MΩ: ± 4 divisions from center screen
1 mV to 100 mV; 2nd harmonic distortion of –30 dBc
101 mV to 5 V; 2nd harmonic distortion of –20 dBc
DC voltage measurement
accuracy 2
Dual cursor:
± [(DC gain accuracy) + (resolution)]
Single cursor:
± [(DC gain accuracy) + (offset accuracy) + (resolution/2)]
RMS noise loor (Vrms ac) on 50 Ω inputs
Vertical setting (Volts/div)
S-054A
S-104A
S-204A
S-254A
S-404A
S-604A
S-804A
1 mV/div
74 uV
90 uV
120 uV
130 uV
153 uV
195 uV
260 uV
2 mV/div
74 uV
90 uV
120 uV
130 uV
153 uV
195 uV
260 uV
5 mV/div
77 uV
94 uV
129 uV
135 uV
173 uV
205 uV
320 uV
10 mV/div
87 uV
110 uV
163 uV
172 uV
220 uV
256 uV
390 uV
20 mV/div
125 uV
163 uV
233 uV
254 uV
330 uV
446 uV
620 uV
50 mV/div
372 uV
456 uV
610 uV
650 uV
768 uV
1.3 mV
1.4 mV
100 mV/div
0.78 mV
0.96 mV
1.2 mV
1.3 mV
1.6 mV
2.3 mV
3.1 mV
200 mV/div
1.6 mV
2.0 mV
2.6 mV
2.8 mV
3.4 mV
4.9 mV
6.4 mV
500 mV/div
3.5 mV
4.2 mV
5.5 mV
6 mV
7.3 mV
10.0 mV
13.3 mV
1 V/div
5.1 mV
6.8 mV
9.2 mV
10.1 mV
12.5 mV
17.6 mV
24.1 mV
Vertical - digital channels
Input channels
16 channels of timing
Analog bandwidth
400 MHz
Threshold selections
User-deined, TTL, 5.0 V CMOS, 3.3 V CMOS, 2.5 V CMOS, ECL, PECL
User-deined threshold range
± 8.00 V in 10 mV increments
Maximum input voltage
± 40 V peak
Threshold accuracy
± (100 mV + 3% of threshold setting)
Input dynamic range
± 10 V about threshold
Minimum input voltage swing
500 mV peak-to-peak
Input impedance
100 kΩ ± 2% (~ 8 pF) at probe tip
Channel-to-channel skew
500 ps (typical)
Resolution
1 bit
1. Denotes warranted speciications, all others are typical. Speciications are valid after a 30-minute warm-up period and ± 5 °C from
irmware calibration temperature. Input impedance is valid when V/div scaling is adjusted to show all waveform vertical values within
the oscilloscope display.
2. Vertical resolution = 0.4% of full scale.
3. 50 Ω input: Full scale is deined as 8 vertical divisions. Magniication is used below 2 mV/div, full-scale is deined as 16 mV.
The major scale settings are 5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V. Testing is at maximum sample rate.
1 MΩ input: Full scale is deined as 8 vertical divisions. Magniication is used below 2 mV/div, full-scale is deined as 16 mV.
The major scale settings are 5 mV, 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 2 V, 5 V. Testing is at maximum sample rate.
4. For a 10:1 probe on the 1 MΩ input, vertical scaling is multiplied by 10.
30 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Horizontal
Horizontal System: scope channels
Main timebase range
5 pS/div to 20 S/div
Resolution
1 ps
Modes
Main, delayed, roll *(200 ms to 20 sec)
Reference position
Left, center, right
Horizontal position range
0 to ± 200 S
Delayed sweep range
1 pS/div to current main time scale setting
Time scale accuracy1
± (12 ppb initial + 75 ppb/year aging)
Oscilloscope channel deskew
Range = –1 ms to +1 ms
Delta-time measurement accuracy 2,3,4,5
Single-shot peak-to-peak measurement
5 • √(Noise/(Slew Rate))2 + (Intrinsic Jitter)2 + Time Scale Accuracy • Reading Seconds
2
Absolute with 256 averages
0.35 • √(Noise/(Slew Rate))2 + (Intrinsic Jitter)2 + Time Scale Accuracy • Reading Seconds
2
(
)
(
)
Jitter measurement loor 2,3
Intrinsic jitter 2
Time interval
1.
2.
3.
4.
5.
error4
Acquired time range
Intrinsic jitter (typical)
< 1 µs
100 ns/div
100 fs rms
10 µs
1 µs/div
123 fs rms
100 µs
10 µs/div
138 fs rms
1 ms
100 µs/div
145 fs rms
10 ms
1 ms/div
200 fs rms
TIE: √(Noise/(Slew Rate))2 + (Intrinsic Jitter)2 Seconds rms
Period jitter
√2 • √(Noise/(Slew Rate))2 + (Intrinsic Jitter)2
Seconds rms
Cycle-cycle jitter (N=1)
√3 • √(Noise/(Slew Rate))2 + (Intrinsic Jitter)2
Seconds rms
Denotes warranted speciications, all others are typical. Speciications are valid after a 30-minute warm-up period and ± 5 °C from
irmware calibration temperature. Input impedance is valid when V/div scaling is adjusted to show all waveform vertical values within the
oscilloscope display.
Conditions: Input - 725 mVpp signal, scope BW 8 GHz, 120 mV/div, 20 GSa/s sample rate, sin(x)/x interpolation enabled, measurement
threshold ixed at 50% of the peak-to-peak signal amplitude, measurement derived from single edge (rising or falling).
Noise is the displayed rms noise loor over the entire width of the display. Slew rate is the displayed or calculated (peak signal amplitude · 2πf) slew rate at
the threshold crossings. Conditions: 20 GSa/s sample rate, sin(x)/x interpolation enabled, measurement threshold ixed at 50%
of the peak-to-peak signal amplitude. Intrinsic jitter is time range dependent.
Time ranges ≤ 10 us.
Values represent time error between two edges on a single channel. Standard deviation value refers to the stand deviation of 256 consecutive measurements. Reading is the displayed DTMA measurement value.
31 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Acquisition and trigger
S-054A
S-104A
S-204A
S-254A
S-404A
S-604A
Acquisition - scope channels
Maximum real time sample rate
4 x 10 GSa/s or 2 x 20 GSa/s
Standard memory depth
50 Mpts x 4 channels, 100 Mpts x 2 channels
Memory options
Option 100: 100 Mpts x 4 channels, 200 Mpts x 2 channels
Option 200: 200 Mpts x 4 channels, 400 Mpts x 2 channels
Option 400: Option 400: 400/200 Mpts x 4 channels, 800/400 Mpts x 2 channels at 20 GSa/s, 400/200 x 2
channels at 10 GSa/s, 536/268 Mpts x 2 channels at ≤ 5 GSa/s (single/repetitive mode), 800/400 Mpts x 2
channels (single/repetitive mode)
Sampling modes
Real time
Real time with peak detect
High resolution (10, 11, 12 bit user selection)
Equivalent time
Segmented memory (minimum time between segments = 3.3 us)
Memory depth
Maximum number of segments
Standard (50 Mpts/ch)
16,384
100 Mpts/ch
32,768
200 Mpts/ch
65,536
400 Mpts/ch
65,536
Roll (200 ms to 20 sec)
Filters
Sin(x)/x interpolation
Acquisition - digital channels
Maximum real time sample rate
2 GSa/s
Max memory depth per channel
128/64 Mpts with 2 GSa/s, 64/32 Mpts with < 2 GSa/s (single/repetitive)
Minimum width glitch detect
2 nS
DSO/MSO models
S-054A
S-104A
S-204A
S-254A
S-404A
S-604A
Trigger – scope channels
Ch 1,2,3,4, aux, and line
Max trigger freq on 50 Ω path
Full bandwidth
Sensitivity
1 MΩ input (edge trigger): DC to 500 MHz, 0.4 div
50 Ω input (edge trigger): DC to 3 GHz, 0.4 div (2 mV/div and greater)
Auxiliary (edge trigger): DC to 3 GHz (minimum input: 300 mVpp)
Trigger level range - any channel
Ch 1,2,3,4: 50 Ω: ± 4 divisions from center screen
Ch 1,2,3,4:1 MΩ: ± 4 divisions from center screen
Auxiliary: ± 5 V (50 Ω) (maximum input: 5 Vpp)
Sweep modes
Auto, triggered, single
Display jitter (with jitter-free
on)1,2
3 GHz bandwidth
< 1.0 ps rms
Trigger hold off range
100 ns to 10 s
Trigger actions
Specify an action to occur (and the frequency of the action) when a trigger condition occurs.
Actions include: email on trigger and execute “multipurpose” user settings
Trigger coupling
50Ω and 1 MΩ: DC, or AC: (10 Hz) low frequency reject (50 kHz high pass ilter), high frequency reject
(50 kHz low pass ilter)
1. Internal edge trigger mode. Trigger threshold – ixed voltage at 50% level.
2. Display jitter example. At 100 mV/div, typical noise values are 1.6 mV rms for DSO-S404A.
For slew rate of 500 mV pp sin wave with frequency equal to max analog bandwidth, typical display jitter is 800 fs RMS.
32 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Trigger
Trigger: digital channels MSO models
Threshold range (user deined)
± 8.0 V in 10-mV increments
Threshold accuracy
± (100 mV + 3% of threshold setting)
Trigger modes
Edge (analog and digital)
Triggers on a speciied slope (rising, falling or alternating between rising and falling) and voltage level on
any channel.
Edge transition (analog)
Trigger on rising or falling edges that cross two voltage levels in > or < the amount of time speciied.
Edge transition setting from 250 ps.
Edge then edge (time) (analog and digital)
The trigger is qualiied by an edge. After a speciied time delay between 10 ns to 10 s, a rising or falling
edge on any one selected input will generate the trigger.
Edge then edge (event) (analog and digital)
The trigger is qualiied by an edge. After a speciied delay between 1 to 16,000,000 rising or falling
edges, another rising or falling edge on any one selected input will generate the trigger.
Glitch (analog and digital)
Triggers on glitches narrower than the other pulses in your waveform by specifying a width less than
your narrowest pulse and a polarity. Glitch range settings equal pulse width settings
Pulse width (analog and digital)
Trigger on a pulse that is wider or narrower than speciied. Pulse width range setting is 250 ps to 10 s for
analog channels and 2 ns to 10 s for digital channels
1 GHz and 500 MHz model
Minimum detectable pulse width:
150 ps for analog channels
1 ns for digital channels
2 GHz and 2.5 GHz model
Minimum detectable pulse width:
100 ps for analog channels
1 ns for digital channels
4 GHz, 6 GHz, 8 GHz model
Minimum detectable pulse width:
50 ps for analog channels
1 ns for digital channels
Runt (analog)
Triggers on a pulse that crosses one threshold but fails to cross a second threshold before crossing the
irst again. Runt settings equal pulse width settings.
Timeout (analog and digital)
Trigger when a channel stays high, low, or unchanged for too long.
Timeout settings equal pulse width settings.
Pattern/pulse range
Triggers when a speciied logical combination of the channels is entered, exited, present for a
(analog and digital)
speciied period of time or is within a speciied time range or times out. Each channel can have a value of
High (H), Low (L) or Don’t care (X).
State (analog and digital)
Pattern trigger clocked by the rising, falling or alternating between rising and falling edge of one channel.
Setup/hold (analog)
Triggers on setup, hold, or setup and hold violations in your circuit. Requires a clock and data signal on
any two inputs (except aux or line) channels as trigger sources. Setup and/or hold time must then be
speciied.
Window (analog)
Trigger on entering, exiting, or inside speciied voltage range
Protocol packets
Requires speciied protocol option, I2C, SPI, CAN, LIN, RS-232/UART, SVID, USB, PCIe® Gen 1
Zone-qualiied
Requires IniniiScan software option. SW-based triggering across up to 8 user-drawn zones. For each
zone, user speciies “must intersect” or “must not intersect.” Zones can be drawn on multiple channels
and combined using Boolean expressions.
33 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Measurements and math
Measurements and math
Math functions can operate on any combination of channels, memories, or other functions.
Math functions
Up to 16 independent functions
Gates
Up to 16 (any function can be used as a gate)
Waveform measurements
Can be made on either main, zoom, or gated region with up to 20 simultaneous measurements
Waveform memories
Four for scope waveforms, one memory that includes all digital channels simultaneously
Voltage (scope channels)
Peak-to-peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, V overshoot, preshoot, V preshoot, upper, middle, lower, crossing point voltage , pulse top, pulse base, pulse amplitude
Time (digital channels)
Period, frequency, positive width, negative width, duty cycle, delta time
Time (scope channels)
Rise time, fall time, period, frequency, positive width, negative width, duty cycle, Tmin, Tmax, Tvolt, channel-tochannel delta time, channel-to-channel phase , count pulses , burst width, burst period, burst interval, setup time,
hold time
Mixed (scope channels only)
Area, slew rate
Frequency domain
FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude
Level qualiication
Any channels that are not involved in a measurement can be used to level-qualify all timing
measurements
Eye-diagram measurements
Eye height, eye width, eye jitter, crossing percentage, Q factor, and duty-cycle distortion
Measurement modes
Statistics
Displays the mean, standard deviation, minimum, maximum range, and number of measurement values for the
displayed automatic measurements
Histograms
Source
Waveform or measurement
Orientation
Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are deined
using waveform markers
Measurements
Mean, standard deviation, mean ± 1, 2, and 3 sigma, median, mode, peak-to-peak, min, max, total hits, peak (area of
most hits), X scale hits, and X offset hits
Marker modes
Manual markers, track waveform data, track measurements, and delta marker values can be displayed
Waveform math
Operators
Absolute value, add, AM demodulation, average, gating, Butterworth1, common mode, differentiate,
divide, envelope, FFT magnitude, FFT phase, FIR1, high pass ilter, integrate, invert, LFE1, low pass ilter (4th-order
Bessel Thompson ilter), magnify, max, min, multiply, RT Eye1, smoothing,
SqrtSumOfSquare1, square, square root, subtract, versus, chart (MSO models)
Automatic measurements
Measure menu access to all measurements, up to 20 measurements can be displayed simultaneously
Multipurpose
User-selectable for saving images when pressed or taking a series of measurements deined by the user, or other
actions
Drag-and-drop measurement
toolbar
Measurement toolbar with common measurement icons that can be dragged and dropped onto the
displayed waveforms
FFT (FFT viewer is standard)
Frequency range
DC to 10 GHz (at 20 GSa/s) or 5 GHz (at 10 GSa/s)
Frequency resolution
Resolution = sample rate/memory depth
Window modes
Hanning, lattop, rectangular, Blackman Harris, Hamming
1. Requires MATLAB software and license.
34 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Display, computer system, and IO ports
Display
Display
XGA 15” capacitive touch screen
Resolution
Ininiium application runs with 1024 pixels horizontally x 768 pixels vertically
Annotation
Up to 100 bookmarks can be inserted into the waveform area. Each can loat or be tied to a speciic waveform
Grids
Up to 16 grids per waveform area
Waveform areas
Up to 8
Waveform styles
Connected dots, dots, variable persistence, ininite persistence, color graded ininite persistence
Computer system and peripherals, I/O ports
Computer system and peripherals
Operating system
Windows 7 Embedded Standard
CPU
3 GHz Intel i5 quad core
PC system memory
8 GB RAM
Drives
≥ 250 GB removable SSD (solid state drive)
Peripherals
Optical USB mouse and compact keyboard supplied. All Ininiium models support any Windows-compatible input device
with a USB interface
IO Ports
LAN
RJ-45 connector, supports 10Base-T, 100Base-T, and 1000Base-T. Enables Web-enabled remote control, email on trigger, data/ile transfers and network printing
USB
7 total ports:
– Two USB 2.0 ports on the front
– Four USB ports on the side (two are USB 3.0 and two are USB 2.0)
– One USB 3.0 port on side supporting up to 200 MB/s data ofload
External display
Drivers support up to two simultaneous displays
DisplayPort and VGA video out
Trigger out
TTL levels into high impedance load
File types
Oscilloscope waveforms:
Compressed:
Internal formats:
*.wfm, *.bin, *.h5, and *.osc composite (setup and waveforms)
Larger formats:
*.csv, *.tsv, and*.txt
Digital waveform:
Support in .osc or .h5 formats
Images
.bmp, .tiff, .gif, .png or .jpg
Auxiliary output
DC (± 2.4 V), square wave
Time base reference output
Amplitude into 50 Ω: 1.65 Vpp ± 50 mV sine wave (8.3 dBm ± 0.3 dB) regardless of whether it is derived from the internal
or the external reference
Frequency from internal reference:
– 10 MHz ± 100 ppb if it has been calibrated within the last year
Time base external reference
input (impedance into 50 Ω)
Frequency: 10 MHz ± 20 ppm
Amplitude: 356 mVpp (–5 dBm) minimum to 5 Vpp (+18 dBm) maximum
LXI compliance
LXI class C
35 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
Ininiium S-Series Performance Characteristics (continued)
Environmental and general
Temperature
Operating 5 to 40°C
Non-operating –40 to +65°C
Humidity
Operating up to 90% relative humidity (non-condensing) at +40 °C
Non-operating up to 90% relative humidity (non-condensing) at +65 °C
Altitude
Operating up to 4,000 meters (12,000 feet)
Non-operating up to 15,300 meters (50,000 feet)
Vibration
Operating random vibration 5-500 Hz, 10 minutes per axis, 0.3 g (rms)
Non-operating random vibration 5-500 Hz, 10 minutes per axis, 2.41 g (rms); resonant search 5-500 Hz,
swept sine, 1 octave/minute sweep rate, (0.75 g), 5 minute resonant dwell at 4 resonances per axis
Power
100-120 V, ± 10% 50/60/400 Hz
100-240 V, ± 10% 50/60 Hz
Max power dissipated: 380 W
Typical operator noise
35 dB at front of instrument
Weight
Frame: 12 kg (26.4 lbs). Shipping:
Dimensions
(with feet retracted)
Height: 12.9 in (33 cm); width: 16.8 in (43 cm); depth: 9 in (23 cm)
Safety
CAN/CSA22.2 No. 61010-1-12 UL Std. 61010-1 (3rd Edition)
Electromagnetic
compatibility standards
IEC 61326-1:2005/EN 61326-1:2006
CISPR 11/EN 55011
IEC 61000-4-2/EN 61000-4-2
IEC 61000-4-3/EN 61000-4-3
IEC 61000-4-4/EN 61000-4-4
MTBF
(mean time before failure)
110,000 hours (typical)
Sanitation
Keysight Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
36 | Keysight | Ininiium S-Series High-Deinition Oscilloscopes – Data Sheet
From Hewlett-Packard through Agilent to Keysight
For more than 75 years, we‘ve been helping you unlock measurement insights.
Our unique combination of hardware, software and people can help you reach
your next breakthrough. Unlocking measurement insights since 1939.
1939
THE FUTURE
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a full one-year warranty on all accessories, calibration devices, systems and
custom products.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to five years of protection and no budgetary surprises to ensure your
instruments are operating to specification so you can rely on accurate
measurements.
Keysight Infoline
www.keysight.com/find/service
Keysight’s insight to best in class information management. Free access to
your Keysight equipment company reports and e-library.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Paciic
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-24-15)
PCI-SIG®, PCIe® and the PCI Express® are US registered trademarks
and/or service marks of PCI-SIG.
MIPI® and M-PHY® are registered trademarks owned by the MIPI Alliance.
D-PHY™ is a trademark of the MIPI Alliance.
www.keysight.com/find/S_Series
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2014, 2015
Published in USA, October 12, 2015
5991-3904EN
www.keysight.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising