BA BNI IOL-802-000-Z03x_006 E_915905

BA BNI IOL-802-000-Z03x_006 E_915905
BNI
BNI
BNI
BNI
IOL-802-000-Z036
IOL-802-000-Z036-006
IOL-802-000-Z037
IOL-802-000-Z037-006
Smart Light
User’s Guide
Content
1
Notes to the user
1.1 About this guide
1.2 Structure of the guide
1.3 Typographical conventions
Enumerations
Actions
Syntax
Cross-references
1.4 Symbols
1.5 Abbreviations
3
3
3
3
3
3
3
3
3
3
2
Safety
2.1 Intended use
2.2 Installation and startup
2.3 General safety instructions
2.4 Resistance to aggressive substances
Hazardous voltage
4
4
4
4
4
4
3
Getting Started
3.1 Overview BNI IOL-802-000-Z036
3.2 Overview BNI IOL-802-000-Z037
3.3 Mechanical connection
3.4 Electrical connection
3.5 Function ground
3.6 IO-Link connection
Smart Light connection
Module versions
3.7 Short description of the functionality
3.8 Segment mode
3.9 Level mode
3.10 Runlight mode
5
5
6
7
7
7
7
7
7
8
8
8
11
4
IO-Link Interface
4.1 IO-Link Data
4.2 Process data / Output data
BNI IOL-802-000-Z03x, Segment Mode
Bit definitions in segment mode
BNI IOL-802-000-Z03x, Level Mode
Bit definitions in level mode
BNI IOL-802-000-Z03x, Runlight Mode
Bit definitions in runlight mode
4.3 Parameter data/ Request data
Mode 40hex
Number of segments 41hex
Level type 42hex
Level resolution 43hex
Level mode segment x color 44hex 45hex 46hex 47hex 48hex
Level mode limit x-y 49hex 4Ahex 4Bhex 4Chex
Runlight mode, background color 4Dhex
Runlight mode, running color 4Ehex
Runlight mode, number of running segments 4Fhex
Supply monitoring 50hex
Brightness 51hex
Blinking frequency / Runlight speed 52hex
Blinking mode 53hex
User color FChex
Limit type FDhex
Buzzer type FEhex
4.4 Errors
12
12
12
12
12
13
13
14
14
15
17
17
17
17
17
18
19
19
19
20
20
21
21
21
22
22
22
www.balluff.com
1
Balluff / IO-Link BNI IOL-802-000-Z03x
4.5 Events
22
5
Technical Data
5.1 Dimensions
5.2 Mechanical data
5.3 Electrical data
5.4 Operating conditions
5.5 LED indicator
Status LED
23
23
23
24
24
25
25
6
Appendix
6.1 Product ordering code
6.2 Order information
Included material
26
26
26
26
www.balluff.com
2
1
Notes to the user
1.1 About this guide
This guide describes the Balluff BNI IOL-802-000-Z03x for the application as status light
module. Hereby it is about an IO-Link device which communicates by means of IO-Link
protocol with the superordinate IO-Link master assembly.
1.2 Structure of the
guide
The guide is organized so that the sections build on one another.
Section 2: Basic safety information.
Section 3: The main steps for installing the device.
Section 4: IO-Link, parameter and process data for the device.
Section 5: Technical data for the device.
1.3 Typographical
conventions
The following typographical conventions are used in this Guide.
Enumerations
Enumerations are shown in list form with bullet points.
•
Entry 1,
•
Entry 2.
Actions
Action instructions are indicated by a preceding triangle. The result of an action is indicated
by an arrow.
 Action instruction 1.

Action result.
 Action instruction 2.
Syntax
Numbers:
Decimal numbers are shown without additional indicators (e.g. 123),
Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex).
Cross-references
Cross-references indicate where additional information on the topic can be found (see
Section 5 -"Technical Data“).
1.4 Symbols
Note!
This symbol indicates a security notice which must be observed.
Note, tip
This symbol indicates general notes.
1.5
Abbreviations
www.balluff.com
BNI
DPP
EMC
FE
IOL
ISDU
Balluff Networking Interface
Direct Parameter Page
Electromagnetic Compatibility
Function Earth
IO-Link
Indexed Service Data Unit
3
Balluff / IO-Link BNI IOL-802-000-Z03x
2
Safety
2.1 Intended use
2.2 Installation and
startup
2.3 General safety
instructions
2.4 Resistance to
aggressive
substances
Hazardous
voltage
This guide describes the Balluff BNI IOL-802-000-Z03x for the application as status light
module. Hereby it is about an IO-Link device which communicates by means of IO-Link
protocol with the superordinate IO-Link master assembly.
Note
Installation and startup are to be performed only by trained specialists. Qualified
personnel are persons who are familiar with the installation and operation of the
product, and who fulfills the qualifications required for this activity. Any damage
resulting from unauthorized manipulation or improper use voids the
manufacturer's guarantee and warranty. The Operator is responsible for
ensuring that applicable of safety and accident prevention regulations are
complied with.
Commissioning and inspection
Before commissioning, carefully read the operating manual.
The system must not be used in applications in which the safety of persons is dependent on
the function of the device.
Authorized Personnel
Installation and commissioning may only be performed by trained specialist personnel.
Intended use
Warranty and liability claims against the manufacturer are rendered void by:
 Unauthorized tampering
 Improper use
 Use, installation or handling contrary to the instructions provided in this operating
manual
Obligations of the Operating Company
The device is a piece of equipment from EMC Class A. Such equipment may generate RF
noise. The operator must take appropriate precautionary measures. The device may only be
used with an approved power supply. Only approved cables may be used.
Malfunctions
In the event of defects and device malfunctions that cannot be rectified, the device must be
taken out of operation and protected against unauthorized use.
Intended use is ensured only when the housing is fully installed.
Note
The BNI modules generally have a good chemical and oil resistance. When
used in aggressive media (eg chemicals, oils, lubricants and coolants each in
high concentration (ie, low water content)) must be checked prior applicationrelated material compatibility. In the event of failure or damage to the BNI
modules due to such aggressive media are no claims for defects.
Note
Disconnect all power before servicing equipment.
Note
In the interest of product improvement, the Balluff GmbH reserves the right to
change the specifications of the product and the contents of this manual at any
time without notice.
www.balluff.com
4
3
Getting Started
3.1 Overview BNI IOL802-000-Z036
1
2
3
4
5
6
10
7
9
8
Fig. 3-1: BNI IOL-802-000-Z036
1
2
3
4
5
www.balluff.com
Cap
Segment 1
Segment 2
Segment 3
Segment 4
6
7
8
9
10
Segment 5
Socket
M12 connector
M18 thread for mounting
Status LED
5
Balluff / IO-Link BNI IOL-802-000-Z03x
3
Getting Started
3.2 Overview BNI IOL802-000-Z037
1
2
3
4
5
6
10
7
9
8
Fig. 3-2: BNI IOL-802-000-Z037
1
2
3
4
5
www.balluff.com
Cap with buzzer
Segment 1
Segment 2
Segment 3
Segment 4
6
7
8
9
10
Segment 5
Socket
M12 connector
M18 thread for mounting
Status LED
6
3
Getting Started
3.3 Mechanical
connection
The BNI IOL-802-000-Z03x modules are attached by using an M18 nut.
3.4 Electrical
connection
The BNI IOL-802-000-Z03x modules require no separate supply voltage connection. Power
is provided through the IO-Link interface by the host IO-Link Master.
3.5 Function ground
FE terminal
with a screw
to connect
protection
ground
Note!
The FE connection from the housing to the machine must be low-impedance
and as short as possible.
3.6 IO-Link
connection
Smart Light
connection
IO-Link (M12, A-coded, male)
Pin
Function
1
Power supply controller, +24V
2
-
3
GND, reference potential
4
C/Q, IO-Link Data transmission channel
 Connection protection ground to FE terminal, if present.
 Connect the incoming IO-Link line to the Smart Light.
Note, tip!
A standard 3 wire sensor cable is used for connecting to the host IO-Link
master.
Module versions
Version
BNI IOL-802-000-Z036
BNI IOL-802-000-Z036-006
BNI IOL-802-000-Z037
BNI IOL-802-000-Z037-006
www.balluff.com
Description
Maximum 5 segment configurable signal light with
level meter and runlight mode.
Maximum 5 segment configurable signal light with
level meter and runlight mode. In die-cast zinc
housing with chrome finishing.
Maximum 5 segment configurable signal light with
level meter, runlight mode and buzzer.
Maximum 5 segment configurable signal light with
level meter, runlight mode and buzzer. In die-cast
zinc housing with chrome finishing.
7
Balluff / IO-Link BNI IOL-802-000-Z03x
3
Getting Started
3.7 Short description
of the
functionality
The functionality of the Balluff status light module can be controlled through process data
and ISDU registers. It has three main mode of functionality:
 Segment mode
 Level mode
 Runlight mode
With the help of these three modus various warning and indication signals can be indicated.
The buzzer function is available in all modes.
3.8 Segment mode
To use the module as a standard status light, the Mode ISDU register must be set to
segment mode. In the segment mode the module can be used as a standard status light,
with configurable number of segments. Maximum five segments can be set. Irrespectively of
the selected number of segments, always all of the LEDs are used as a display element.
The number of the segments can be set any number between 1 and 5. The module has 20
LEDs, which are equally distributed between the segments. (When three segments are set,
one-one LEDs between the segments will be always switched off). The color of each
segment can be selected from a color table, which has six pre-defined colors and one user
defined color. The combinations of the pre-defined colors are not limited. In the segment
mode, the segments can be set to blink too. Each segment has a control bit in process data,
which determines the blinking of the corresponding segment. The blinking has two modus.
Either normal blinking or flash mode can be selected. In normal blinking the LEDs are
switched on and off periodically with a 50% duty cycle. In the flash mode, the LEDs are
switched on and off quickly three times. The flash is repeated in every second. The type of
the blinking can be set in ISDU register. The frequency of the normal blinking can be
changed through an ISDU register.
3.9 Level mode
To use the signal light as a level meter, the Mode ISDU register must be set to level mode.
In level mode the complete module works as one indicator element. In this case a level
value can be displayed. The process data does not give the colors of the segment, but the
level. The higher value the module becomes, the more LEDs will be switched on. This mode
can be used as a level indicator, for example to indicate a fluid level in a tank. The
resolution of the input level can be selected from 8 bit up to 16 bit. In the level mode various
parameters can be controlled through ISDU registers. These parameters should be set
before the level mode is used. The level display can be selected to be bottom-up or topdown. In the bottom-up mode the level indicator increases from the bottom of the module. In
the top-down mode the indicator increases from the top of the module.
Although there are no real segments in the level mode, because the LEDs are controlled by
the input level, the LEDs are divided into five virtual segments. These virtual segments can
have their own color. The color of these segments can be set through ISDU register (Level
mode segment x color ISDU register). So it can be realized, that the level meter can have
more colors (up to the maximum number of the segments). Some or all colors can be set as
dominant color. This means, when the input level is high enough to switch on the next LED
and this LED is in another virtual segment, the LEDs, which are under the actual LED, take
over the color of the actual LED. In this case, as the input level increases, the color of the
full LED bar can be changed.
For example:
The lower two segments are green, the middle two segments are yellow and the upper
segment is red. The LEDs are shown in the next figures, when the Smartlight level mode is
configured differently.
www.balluff.com
8
3
Getting Started
The LED bar at increasing input data and no color dominance. (The virtual segments can be
seen on the left side.) Of course the segment 2 or 4 does not have to be the same color as
segment 3 or 5.
Seg. 1
Seg. 2
Seg. 3
Seg. 4
Seg. 5
www.balluff.com
9
Balluff / IO-Link BNI IOL-802-000-Z03x
3
Getting Started
The LED bar at increasing input data, all the colors are dominant.
Seg. 1
Seg. 2
Seg. 3
Seg. 4
Seg. 5
www.balluff.com
10
3
Getting Started
By default the 20 LEDs are divided into equal virtual segments. The height of the virtual
segments can be modified too. There are four ISDU registers (Level mode limit x-y ISDU
register), in which the limits of the virtual segments can be modified. For example: If the
input level value is higher than the limit value of the 2. and 3. segment (Level mode limit 23), the current LED will become the color of the Level mode segment 2 color. The limits can
be given either in percent or in absolute value.
The LED bar at increasing input data, there is no color dominance. The limits of the
segments are modified, so they are not equally distributed. Of course segment 3, 4 and 5
could have different colors too.
Seg. 1
Seg. 2
Seg. 3
Seg. 4
Seg. 5
3.10 Runlight mode
www.balluff.com
To use the module as a runlight display, the Mode ISDU register must be set to runlight
mode. In the runlight mode, the complete module displays a running light effect. In this case
all of the LEDs are working as one runlight effect. The runlight mode is controlled by ISDU
registers.
Four registers set the functionality of the runlight. The color of the running LEDs, the
background color, the number of the running segments and the speed of the running
segment can be set in the ISDU registers. One segment has a size of 4 LEDs. The number
of the running segment can be set between 1 and 3.
11
Balluff / IO-Link BNI IOL-802-000-Z03x
4
IO-Link Interface
4.1 IO-Link Data
The BNI IOL-802-000-Z036 and BNI IOL-802-000-Z037 Smart Light modules have 3 byte
output process data. The output process data has different meaning depending on the
selected mode (segment mode, level mode or runlight mode).
BNI IOL-802-000-Z036, BNI IOL-802-000-Z037
Data transmission rate
COM2 (38,4 kBaud)
Minimal cycle time
5 ms
Process data length
3 Byte output
IO-Link Revision
1.1
Frame type
2.V
Process data cycle time* 5 ms
* by min. cycle time
1.0
1
30 ms
4.2 Process data /
Output data
7
6
5
4
3
2
1
0
Segment 3
color
0
Segment 1
color
1
6
5
4
3
-
-
Segment 5 blink
2
1
0
Segment 5
color
7
-
Description
Bit definitions
in segment
mode
2
2
Buzzer state
Byte
Bit
1
3
Segment 4
color
4
Segment 2
color
5
Segment 1 blink
6
Segment 3 blink
0
7
Segment 2 blink
Bit
Segment 4 blink
Byte
Description
BNI IOL-802000-Z03x,
Segment Mode
Bit 0-2/4-6, Segment color
Bit 3, Segment blink
000 = Off
001 = Green
010 = Red
011 = Yellow
100 = Blue
101 = Orange*
110 = User defined*
111 = White
0 – Segment does not blink
1 – Segment blinks according to the blink
modus settings
Bit 7, Buzzer state
(Only in case of BNI IOL-802-000-Z037)
0 – Buzzer is off
1 – Buzzer is on
*color is available from software version 2.1
www.balluff.com
12
IO-Link Interface
0
1
3
2
1
MSB
7
MSB
10 bit level value
MSB
12 bit level value
14 bit level value
16 bit level value
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
-
-
-
-
-
-
-
2
Bit
Buzzer state
Byte
Bit
definitions
in level
mode
0
8 bit level value
MSB
Description
4
LSB
5
LSB
6
LSB
7
LSB
Bit
LSB
Byte
MSB
BNI IOL-802000-Z03x,
Level Mode
Description
4
Level value
The 8, 10, 12, 14 or 16 bit value for level indicator. The resolution can be set in Level resolution ISDU
register. The Level value is always left justified.
Bit 7, Buzzer state
(Only in case of BNI IOL-802-000-Z037)
0 – buzzer is off
1 – buzzer is on
www.balluff.com
13
Balluff / IO-Link BNI IOL-802-000-Z03x
IO-Link Interface
-
-
-
-
-
-
-
-
0
-
1
-
2
-
3
-
4
-
5
-
6
7
6
5
4
3
2
1
0
Buzzer state
7
-
0
-
1
-
www.balluff.com
2
Bit
Byte
Bit
definitions
in runlight
mode
1
3
-
4
-
5
-
6
-
7
-
0
Bit
-
Byte
Description
BNI IOL-802000-Z03x,
Runlight
Mode
Description
4
2
Bit 7, Buzzer state
(Only in case of BNI IOL-802-000-Z037)
0 – buzzer is off
1 – buzzer is on
14
IO-Link Interface
4.3 Parameter data/
Request data
DPP
Index
ISDU
Index
Object name
07hex
08hex
09hex
0Ahex
0Bhex
Identification Data
Length
Subindex
Access
right
Default Value
Vendor ID
2 Byte
0378hex
Device ID
3 Byte
050A01 hex
050A03hex
10hex
0
Vendor name
7 Byte
BALLUFF
11hex
0
Vendor text
15 Byte
www.balluff.com
12hex
0
Product
name
20 Byte
24 Byte
13hex
0
Product ID
7 Byte
14hex
0
Product text
21 Byte
28 Byte
33 Byte
40 Byte
16hex
0
Hardware
Revision
1 Byte
17hex
0
Firmware
Revision
48 Byte
18hex
0
Application tag*
32 Byte
Read only
4
BNI IOL-802-000-Z036
BNI IOL-802-000-Z036-006
BNI IOL-802-000-Z037
BNI IOL-802-000-Z037-006
BNI007F
BNI0072
Smart Light 5 segment
Smart Light 5 segment
Chrome
Smart Light 5 segment with
buzzer
Smart Light 5 segment with
buzzer Chrome
Read /
Write
* 32 Byte string adjustable by the user
www.balluff.com
15
Balluff / IO-Link BNI IOL-802-000-Z03x
IO-Link Interface
ISDU
Parameter Data
4
Object name
Length
Range
Default
Value
0
Mode
1 Byte
0…2
0
41hex
0
Number of segments
1 Byte
1…5
5
42hex
0
Level type
1 Byte
0…1
0
43hex
0
Level resolution
1 Byte
0…4
0
44hex
0
1 Byte
0hex…Fhex
2hex
45hex
0
1 Byte
0hex…Fhex
3hex
46hex
0
1 Byte
0hex…Fhex
3hex
47hex
0
1 Byte
0hex…Fhex
1hex
48hex
0
1 Byte
0hex…Fhex
1hex
49hex
0
2 Byte
0hex…FFFFhex
80
4Ahex
0
2 Byte
0hex…FFFFhex
60
4Bhex
0
2 Byte
0hex…FFFFhex
40
4Chex
0
2 Byte
0hex…FFFFhex
20
4Dhex
0
1 Byte
0…7
0
4Ehex
0
1 Byte
0…7
1
4Fhex
0
1 Byte
1…3
1
Supply monitoring*
1 Byte
-
-
Brightness
3 Byte
0hex…7F7F7Fhex
7F7F7Fhex
Index
Subindex
40hex
50hex
51hex
0
1-2
0
1-3
Level mode
segment 1 color
Level mode
segment 2 color
Level mode
segment 3 color
Level mode
segment 4 color
Level mode
segment 5 color
Level mode
limit 1-2
Level mode
limit 2-3
Level mode
limit 3-4
Level mode
limit 4-5
Runlight mode
background color
Runlight mode
running color
Runlight mode
number of running
segments
52hex
0
Blinking frequency /
Runlight speed
1 Byte
1…5
2
53hex
0
Blinking mode
1 Byte
0hex…1Fhex
0hex
FChex
0
1-3
User color***
3 Byte
0hex…FFFFFFhex
008080hex
FDhex
0
Limit type***
1 Byte
0…1
0
FEhex
0
Buzzer type**
1 Byte
0…3
0
*Read only
**Only in case of BNI IOL-802-000-Z037
***Available from software version 2.1
www.balluff.com
16
IO-Link Interface
Mode
40hex
The operating mode of the Smart Light can be selected in the Mode ISDU register.
0 = Segment mode
1 = Level mode
2 = Runlight mode
Number of
segments
41hex
The number of the displayed segments can be set in this register. The minimum value for the
segment number is one and the maximum value is five.
Note, tip!
When the module is configured to have 3 segments, 1-1 LED is always switched of
between the segments.
Level type
42hex
The type of the level indicator.
0 = bottom up
1 = top down
Level resolution
43hex
The resolution of the input data in level mode.
0 = 8 bit
1 = 10 bit
2 = 12 bit
3 = 14 bit
4 = 16 bit
6
5
4
3
2
1
-
-
Segment x color
Segment x color
0
Segment x color
7
Dominance
0
Bit
-
45hex
46hex
47hex
48hex
Byte
-
Level mode
segment x color
44hex
Description
4
Bit 0-2, Color of the segment
Bit 3, Color dominance
000 = Off
001 = Green
010 = Red
011 = Yellow
100 = Blue
101 = Orange*
110 = User defined*
111 = White
0 - Color is not dominant
1 - Color is dominant
*color is available from software version 2.1
www.balluff.com
17
Balluff / IO-Link BNI IOL-802-000-Z03x
IO-Link Interface
The level limit values are interpreted either as a percent value or as an absolute value
depending on the value of the Limit type register (FDhex). The values are interpreted as a
percent value between 0% and 100% by default. When the Limit type is set to absolute
value, an 8, 10, 12, 14, 16 bit number (depends on the resolution) determines the limits
between two segments in level mode. The limit values are always right justified.
5
4
1
3
2
1
0
7
6
5
MSB
3
2
8 bit limit value
10 bit limit value
12 bit limit value
14 bit limit value
1
0
LSB
MSB
MSB
MSB
Limit type is absolute
4
LSB
6
LSB
0
7
MSB
Bit
LSB
Byte
LSB
Level mode
limit x-y
49hex
4Ahex
4Bhex
4Chex
Limit type
is percent
4
16 bit limit value
Percent value: 0 – 100
Note, tip
Before changing the limit values, the Resolution and Limit type should be set to the
desired value!
www.balluff.com
18
IO-Link Interface
5
4
-
-
3
2
1
0
Background
color
6
-
7
-
0
Bit
-
Byte
Description
Runlight mode,
background color
4Dhex
The background of the runlight effect can be set in this register.
Bit 0-2, Background color
000 = Off
001 = Green
010 = Red
011 = Yellow
100 = Blue
101 = Orange*
110 = User defined*
111 = White
*color is available from software version 2.1
6
5
4
3
-
-
2
1
0
Running
color
7
-
0
Bit
-
Byte
-
Runlight mode,
running color
4Ehex
Description
4
The color of the running segment in runlight mode can be set in this register.
Bit 0-2, Running color
000 = Off
001 = Green
010 = Red
011 = Yellow
100 = Blue
101 = Orange*
110 = User defined*
111 = White
*color is available from software version 2.1
Runlight mode,
number of
running segments
4Fhex
www.balluff.com
Number of the running segments. Each segment contains 4 LED. Values between 1 and 3
can be set.
19
Balluff / IO-Link BNI IOL-802-000-Z03x
7
6
5
4
3
2
1
0
-
-
-
-
-
-
2
1
-
-
-
-
-
LED Voltage failure
Under voltage Us
Bit
Sub
Index
Description
Supply
monitoring
50hex
-
IO-Link Interface
Under voltage Us
0: Us voltage is Ok
1: Low voltage on IO-Link pin 1
LED Voltage failure
0: LED Voltage is Ok
1: LED Voltage failure
Brightness
51hex
www.balluff.com
This register sets the brightness for each channel (red, green and blue). Values from
0x00 to 0x7Fare accepted for each channel. This register can be accessed through the
subindices 0, 1, 2 or 3. Reading/writing the subindex 0 the whole 3 byte brightness data can be
accessed. Subindex 1, 2 and 3 contains the brightness data for red, green and blue channels.
Byte
0
1
2
Sub
Index
1
2
3
Description
4
Brightness value for red
channel
Brightness value for green
channel
Brightness value for blue
channel
20
IO-Link Interface
Blinking
frequency /
Runlight
speed
52hex
The frequency of the blinking in segment mode and the speed of the running segment in runlight
mode can be set in this register. Values between 1 and 5 are accepted. One means the slowest
and five means the fastest blinking or running speed.
Note, tip!
The blinking frequency is only valid for 50% duty cycle blinking. The frequency of the
flashing cannot be changed.
3
2
1
0
Segment 2 flashing
Segment 1 flashing
-
4
Segment 3 flashing
5
Segment 4 flashing
6
Segment 5 flashing
7
-
Bit
1
-
Byte
Description
Blinking
mode 53hex
The segment X flashing bit sets the mode of the blinking.
0 - blinking with 50% duty cycle
1 - flashing
Note!
Through this register only the mode of the blinking can be set (either 50% duty cycle or
flash). The blinking of the desired segment must be activated in process data to enable
blinking.
User color
FChex
This register sets the value of the user defined color. Values for 0x00 to 0xFF are accepted for
each channel. This register can be accessed through the subindices 0, 1, 2 or 3. Reading/writing
the subindex 0 the whole 3 byte user color data can be accessed. Subindex 1, 2 and 3 contains
the red, green and blue channel data for the user color.
Note, tip!
This register is available from software version 2.1.
www.balluff.com
Byte
0
1
2
Sub
Index
1
2
3
Description
4
User defined color, red
channel
User defined color, green
channel
User defined color, green
channel
21
Balluff / IO-Link BNI IOL-802-000-Z03x
4
IO-Link Interface
Limit type
FDhex
The limit registers are evaluated either as a percent value or as an absolute value. The Limit
type register sets the type of the evaluation.
0x00 – Limit type is given in a percent value
0x01 – Limit type is given in an absolute value
Note, tip!
This register is available from software version 2.1.
Buzzer type
FEhex
This register is available only for BNI IOL-802-000-Z037. The type of the buzzer sound can be
set in this register. This register is available only for BNI IOL-802-000-Z037.
0 = continuous sound
1 = 1 Hz chopped sound
2 = 5 Hz chopped sound
3 = 3 short beep, 2 sec pause
4.4 Errors
Error Code
0x8011
0x8012
0x8023
0x8030
0x8033
0x8034
4.5 Events
IO-Link Revision 1.0
Event Code
0x5112
IO-Link Revision 1.1
Event Code
0x5111
www.balluff.com
Description
Index not available
Subindex not available
Access Denied
Parameter Value out of Range
Parameter length overrun
Parameter length underrun
Description
Low supply voltage (US)
Description
Low supply voltage (US)
22
5
Technical Data
5.1 Dimensions
BNI-IOL-802-000-Z036-xxx
5.2 Mechanical data
Housing Material
IO-Link-Port
Enclosure rating
Weight
Dimensions
(L × W × H, excluding connector)
www.balluff.com
BNI IOL-802-000-Z037-xxx
BNI IOL-802-000-Z03x:
Polycarbonate transparent - die-cast zinc housing
BNI IOL-802-000-Z03x-006:
Polycarbonate transparent – die-cast zinc housing
with chrome finishing
M12, A-coded, male
BNI IOL-802-Z036-xxx
IP65 (only when plugged-in)
BNI IOL-802-Z037-xxx
IP30 (only when plugged-in)
BNI IOL-802-000-Z036-xxx: ca. 500 g
BNI IOL-802-000-Z037-xxx: ca. 570 g
BNI IOL-802-000-Z036-xxx: 310 × 60 × 60 mm
BNI IOL-802-000-Z037-xxx: 330 × 60 × 60 mm
23
Balluff / IO-Link BNI IOL-802-000-Z03x
5
Technical Data
5.3 Electrical data
5.4 Operating
conditions
Operating voltage
Ripple
18 ... 30,2 V DC, per EN 61131-2
<1%
Current draw all segments off
Current draw all segments white,
buzzer on
Volume of the buzzer module
Tone frequency of the buzzer
module
Total number of signal lights (all 3
pages)
≤ 40 mA @24V
BNI IOL-802-000-Z036-xxx: ≤ 400 mA @ 24V
BNI IOL-802-000-Z037-xxx: ≤ 410 mA @ 24V
100dB at 1m distance
Operating temperature
Storage temperature
EMC
Immunity tests
Emission tests
-5 °C … +50 °C
-15 °C … +50 °C
EMC-directive 2004/108/EC
EN 61000-6-2:2005 /AC:2005
EN 61000-6-4:2007/A1:2011
EN 60068-2-6
EN 60068-2-27
Vibration/shock
www.balluff.com
2800 ± 500 Hz
3 x 20
24
5
Technical Data
5.5 LED indicator
Status LED
Status LED
LED
Status LED
Indicator
Green, green flashing
Function
Status for supply and communication
The status LED indicates the current status of the power supply and the communication.
It can be switched on, switched of and flashing.
Communication error
Communication ok
LED is flashing
Supply modul
undervoltage
LED is static off
LED is flashing
Supply module ok
www.balluff.com
LED is static on
25
Balluff / IO-Link BNI IOL-802-000-Z03x
6
Appendix
6.1 Product ordering
code
BNI IOL-802-000-Z03x-xxx
Balluff Networking Interface
IO-Link Interface
802: Smart Light 5 Segment
Standard version
Mechanical design
Die-cast zinc housing
Polycarbonate transparent housing
Bus connection M12 external thread,
Module fastening M18 external thread
Z036: Smart Light without buzzer
Z037: Smart Light with buzzer
Finishing
Empty: Matte nickel plated
006: Chrome finising
6.2 Order information
Included material
www.balluff.com
Type
BNI IOL-802-000-Z036
BNI IOL-802-000-Z036-006
BNI IOL-802-000-Z037
BNI IOL-802-000-Z037-006
Order Code
BNI0072
BNI0081
BNI0083
BNI0084
BNI IOL-802-000-Z03x consists of the following components:
 signal light
 M18x1 nut
 rubber foot
 screw M4
 spring washer
 user’s guide
26
Notes
www.balluff.com
27
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Tel. +49 7158 173-0
Fax +49
7158 5010
www.balluff.com
balluff@balluff.de
Nr. 915905 EN  Edition B15  Replaces Edition A15  Subject to modification
www.balluff.com
Was this manual useful for you? yes no