GENERAL SPECIFICATIONS
PVI-3600-OUTD-UK-F-W
PVI-3600-OUTD-US-F-W
PVI-3600-OUTD-IT-F-W
PVI-3600-OUTD-ES-F-W
AURORA® BENEFITS
. PMG (Permanent Magnet Generator) Power Curve implemented in high speed MPPT
. IP65 (NEMA 4X)—The completely sealed, rugged unit can withstand the harshest
conditions
. environmental
High speed MPPT for real time power tracking and improved energy harvesting
. Compact size and high power density: 3600W of output power in a box just
x 326mm x 141mm (16.5in x 12.8in x 5.55in)
. 420mm
Front heatsink keeps the unit cleaner and more efficient over time
. Transformerless operation for highest efficiency—up to 96%
. Reverse polarity protection minimizes chance of damage due to incorrect wiring, only if used
with Aurora PVI-WIND-INTERFACE BOX.
. inHighconjunction
overload capability—works up to 3600W under most ambient conditions
. True Sine Wave Output
. Anti-islanding Protection
. Certified grid connected operation according to the international standards
. LCD on the front to monitor the main parameters and display kW and kWh
. Wind interface box is optional
Optional
Wind Interface Box
HIGH PERFORMANCE REDEFINED
Power-One offers our Aurora PVI-3600 Outdoor Wind Inverter that features revolutionary switching technology. Our Aurora wind inverter includes stateof-the-art silicon power devices that help reduce switching losses. Power devices include power MOS-FET’s and IGBT’s. Robust and reliable, Aurora
was designed to last up to 25 years, and features large derating criteria on all critical components. It delivers true maximum output power on a continuous
basis. With this design concept we achieve peak efficiencies of over 96%. Total current harmonic distortion, on the other hand, is typically less than 2%
through the use of high-frequency switching techniques. Exclusive to Aurora, is its power curve in software that optimizes the wind turbine’s output.
BLOCK DIAGRAM AND TYPICAL EFFICIENCY
DIAGRAMA DE BLOQUES Y RENDIMIENTO TÍPICO
0 OWER; OFRAT EDPOWER=
$#6OLTAGE;6=
5$#6 6
5$#6 6
% FFIC IENC Y; =
%FFICIENCY ; =
5$#6 6
0OWER;OFRATEDOUTPUT=
CHARACTERISTICS
PVI-3600-OUTD-UK-F-W
PVI-3600-OUTD-IT-F-W
PVI-3600-OUTD-US-F-W
PVI-3600-OUTD-ES-F-W
Power Rating Ac [W]
Absolute Max Voltage range [Vdc]
Max. Power Tracking Window range [Vdc]
Power Curve
Nominal AC Frequency [Hz]
Line Power Factor
Maximum AC Line Current [Arms]
3600
0 to 600
50-580 (360 nominal)
Manufacturer special
50
1
16
<2.5% THD at rated power
with sinewave voltage
96 (Euro 95)
<200
-25 to +60
IP65 / NEMA 4 X
0-100% condensing
Derated above 6,600ft (2000m)
< 40
420mm x 326mm x 141mm
(16.5in x 12.8in x 5.55in)
13,5
3600
0 to 600
50-580 (360 nominal)
Manufacturer special
50
1
16
<2.5% THD at rated power
with sinewave voltage
96 (Euro 95)
<200
-25 to +60
IP65 / NEMA 4 X
0-100% condensing
Derated above 6,600ft (2000m)
< 40
420mm x 326mm x 141mm
(16.5in x 12.8in x 5.55in)
13,5
3600
0 to 600
50-580 (360 nominal)
Manufacturer special
60
1
16
<2.5% THD at rated power
with sinewave voltage
96 (Euro 95)
<200
-25 to +60
IP65 / NEMA 4 X
0-100% condensing
Derated above 6,600ft (2000m)
< 40
420mm x 326mm x 141mm
(16.5in x 12.8in x 5.55in)
13,5
3600
0 to 600
50-580 (360 nominal)
Manufacturer special
50
1
16
<2.5% THD at rated power
with sinewave voltage
96 (Euro 95)
<200
-25 to +60
IP65 / NEMA 4 X
0-100% condensing
Derated above 6,600ft (2000m)
< 40
420mm x 326mm x 141mm
(16.5in x 12.8in x 5.55in)
13,5
AC Current Distortion [%]
Max Efficiency [%]
Tare Losses [mW]
Operating Ambient Temperature [°C]
Enclosure Environmental Rating
Relative Humidity
Elevation
Audible Noise [dBA]
Size (height x width x depth) [mm]
Weight [kg]
Model Number
Power
PVI-3600-OUTD-UK-F-W
PVI-3600-OUTD-US-F-W
PVI-3600-OUTD-IT-F-W
PVI-3600-OUTD-ES-F-W
3600W
3600W
3600W
3600W
!NALOGINPUTS
$IGITAL)NPUT/UTPUT
OPTION LIST
Options Suffix
-SC
Description
Screw Terminal Blocks
SMART CONTROLS
Aurora controls are DSP (Digital Signal Processor) based with sophisticated control and self-diagnostics algorithms. An LCD shows the main
operational parameters. Three LED’s indicate the operating status.
0,-
!DDITIONALUNITS
23
ADAPTER
BEST IN CLASS COMMUNICATION
CAPABILITIES
Aurora features an integrated RS485 Communication link. An RS485
to RS232 converter (optional) is available to monitor the unit.
STANDARDS AND CODES
Aurora inverters comply with standards set for grid-tied operation,
safety and electromagnetic compatibility including: CE Certification, CSA- C22.2 N.107.1-01, UL1741, CLEAR SKIES G83/1,
CEI 11-20 IV ed, DK 5940, IEC 61683, IEC 61727, EN 50081,
EN50082, EN61000.
23
!URORA%ASY#ONTROL
%THERNET
0,ADAPTER
).4%2.%4
23
23
4ELEPHONE
OR'3-MODEM
%THERNET
Rev. 1.2 - 19/03/07 - Aurora is a trademark by Power-One - Product is subject to technical improvements
MODEL SUMMARY