Newsteo Catalogue
PRODUCT
CATALOGUE
lAST UPDATE: January 2016
Newsteo
Zone Athélia IV
93 Avenue des Sorbiers
F- 13600 La Ciotat
Tel: +33 (0)4 42 01 82 23
Fax: +33 (0)9 59 83 71 08
www.newsteo.com
HOW DOES IT WORK ?
MONITORING
The logger sends in real time its
measures to the PC. If a measure
is not received by the PC, it
stores it inside its internal
memory and sends it to the PC on
the next communication channel.
1 – THE DATA LOGGERS
RECORDING
They are spread in the area which has to be monitored. They send to the
RF-to-USB key by radiofrequency the measures they take. They can be
wireless configured and updated.
2 - THE RF-TO-USB KEY
It is the bridge between the PC and the loggers.
3 - RF-MONITOR
This software is installed on the PC and allows the monitoring of the
loggers.
The logger records in its
embedded memory the measures
it takes. The user can download
on the PC all the stored measures
when he wants.
CREATE YOUR OWN SENSOR NETWORK…
USING RF MONITOR PREMIUM

The loggers communicate with a PC; the measurements
are displayed only on this PC.
> For single-site installations.
USING RF MONITOR GOLD

Several Loggers networks are created.

Each system communicates to a PC that transmits the
measurement to a central database.

From anywhere in the world, it is possible to connect to
the database to check the measurements.

This consultation is possible with free software DB
Monitor.
>For multi-site installations.
CREATE YOUR OWN SENSOR NETWORK…
USING AN ETHERNET OR GPRS COLLECTOR

The Logger equipped with a sensor takes the measure
and transmits it by radio to the Collector,

The collector transmits the measurements through
Ethernet or GPRS to a central database,

A real-time alert can be sent anywhere to the
supervisor.
>The supervisor can access at any time to the measures,
via Internet
LOG
Loggers
¼
Wavelength
References
Temp. Sensor
PFPN-LOG26-001
-40°C ... +70°C± 0.3°
References
Temp. Sensor
PFPN-LOG36-001
-40°C ... +85°C ± 0.3°
References
Temp. Sensor
PFPN-LOG56-001
-40°C ... +70°C ± 0.3° for both sensors
IP54
Casing
½ AA (LT)
Battery
½
Wavelength
IP65
Casing
AA (LT)
Battery
1/4
Wavelength
IP54
Casing
½ AA (LT)
Battery
Internal
Antenna
References
Temp. Sensor
PFPN-LOM16-001
-40°C ... +70°C ± 0.3°
IP67
Casing
PFKI-LOM16-002
(Set of 5 pieces)
-40°C ... +70°C ± 0.3°
PFPN-LOM18-001
-10°C ... +60°C ± 0.1°
PFKI-LOM18-002
(Set of 5 pieces)
-10°C ... +60°C ± 0.1°
PFPN-LOP16-001
-40°C ... +70°C ± 0.3°, for transportation
PFKI-LOP16-002
(Set of 5 pieces)
-40°C ... +70°C ± 0.3°, for transportation
References
Temp. Sensor
Humidity Sensor*
PFPN-LOG20-001
-40°C ... +70°C± 0.5°
0 … 100% ± 4,5%
PFPN-LOG22-001
-40°C ... +70°C± 0.4°
0 … 100% ± 3%
PFPN-LOG25-001
-40°C ... +70°C± 0.3°
0 … 100% ± 2%
½ AA (LT)
Battery
¼
Wavelength
IP54
Casing
½ AA (LT)
Battery
* Non-condensing area
Dew Point calculation
and display on all our
temperature and
humidity loggers.
LGG
Loggers
1/2
wavelength
IP54
Casing
AA (LT)
Battery
* Non-condensing area
References
PFPN-LGG43-001
Temp. sensor
-25°C ... +55°C
± 0.3°C from 5°C to 55°C
Humidity Sensor*
0 … 95%
± 3% from 20°C to 50°C
CO2 Sensor
0...5000ppm
±50ppm
Air pressure sensor.
300...1100hPa 0°C to 65°C
±1.0typique
±2.5hPa max
NEW
LGR
Loggers
1/2
Wavelength
IP65
Aluminium
AA (LT)
Battery
1/2
Wavelength
References
Interface
PFPN-LGR30-001
PFPN-LGR32-001
PFPN-LGR33-001
PFPN-LGR36-001
PFPN-LGR37-001
PFPN-LGR46-001
For PT100
For Newsteo Temp & Humidity probe
For PT1000
For Newsteo digital Temperature probe
For Thermocouple
For Newsteo Double external probe of
Temperature.
References
Temp. Sensor
PFPN-LGRB6-001
-40°C ... +85°C± 0.3°C
ATEX zone 2 gas certified
References
Temp. Sensor
Humidity Sensor
PFPN-LGR64-001
-40°C ... +85°C± 0.2°C
0 … 100 % ± 1.8%,
dew formation resistant
IP65
Aluminium
AA (LT)
Battery
1/2
Wavelength
IP65
Aluminium
AA (LT)
Battery
LGR
Probes
References
For
Sensor
Interface
Characteristics
PFPN-SNT51-001
LGR31
NTC
-30 to 60°C
NTC probe ± 5%
PFPN‐STE52‐001
LGR30
PT100
-40 to 60°C
Class B
End protected by a heat‐shrinkable sleeve
PFPN‐STE52‐002
LGR30
PT100
-50 to 250°C
Class B
PT100 for food contact, angle probe to insert
PFPN‐STE52‐003
LGR30
PT100
-50 to 250°C
Class B
Straight PT100 end of 150 mm
PFPN‐STE52‐004
LGR30
PT100
PFPN‐STE53‐001
LGR33
PT1000
-40 to 60°C
End protected by a heat‐shrinkable sleeve
PFPN‐STE53‐002
LGR33
PT1000
-40 to 500°C
Probe of stainless steel of 20mm
PFPN‐STE33‐001
LGR33
PT1000
-50 to 180°C
Probe of stainless steel of 100mm
PFPN-STE53-005
LGR33
PT1000
-40 to 60 °C
Probe with ribbon cable for use through a
refrigerator door
PFPN-STE53-006
LGR33
PT1000
PFPN‐STE51‐001
LGR36
Digital Temp.
-40 to 60°C± 0.3°C
End protected by a heat‐shrinkable sleeve
PFPN‐STE51‐002
LGR36
Digital Temp.
-40 to 80°C± 0.3°C
Integrated temperature sensor
PFPN‐STE51‐003
LGR36
Digital Temp.
-40 to 80°C± 0.3°C
Integrated temperature sensor
PFPN-STE51-004
LGR36
Digital Temp.
-40 to 80°C± 0.3°C
Probe with ribbon cable for use through a
refrigerator door
-40 to +80°C° / Class B
Up to +100°C (temporary)
-40 to +80°C° / Class B
Up to +100°C (temporary)
Up to +100°C (temporary)
PT100 with stainless steel
PT1000 with stainless steel
* Non-condensing area.
References
For
Sensor
PFPN-STE51-005
LGR36
Digital Temp
PFPN‐STT51‐001
LGR46
Digital Temp.
PFPN‐STT51‐002
LGR46
Digital Temp.
PFPN‐STT51‐003
LGR46
Digital Temp.
PFPN‐STH54‐001
LGR32
PFPN‐STC01-002
Interface
Characteristics
Up to +100°C (temporary)
-40 to 80°C± 0.3°C
Single temperature probe in stainless steel for
temperature pipe monitoring, cable 5 meters.
-40 to 80°C± 0.3°C
Dual temperature probe
-40 to 80°C± 0.3°C
Up to +100°C (temporary)
Dual temperature probe
Up to +100°C (temporary)
-40 to 80°C± 0.3°C
Dual temperature probe, for temperature pipe
monitoring
Digital Temp. &
Hum.
-40 to +125°C± 0.2°C
0..100%± 1.8%
Integrated temp. & humidity sensor in stainless
steel**
LGR37
Thermocouple K
-100 to 1100°C
Thermocouple K with probe of 250 mm
Supplied with a CON05
PFPN‐STC01‐003
LGR37
Thermocouple T
-75°C to +250°C
Thermocouple K, 5 meters cable
Supplied with a CON05
PFPN‐STC32‐001
LGR37
Thermocouple K
-185°C to +200°C
Thermocouple T
With probe of 200 mm, cable 3 meters
Supplied on a moulded connector
PFPN‐STF51-001
LGR37
Thermal Flux
Thermal Flux
Probe Thermal Flux 50x50m 0.60W/m²
** Dew formation resistant.
LGR
Cable and Connector
References
Type
Compliance
IP
Characteristics
PFPN‐CON05‐001
Connector
LGR37
IP65
To connect any thermocouple (K, E, J, N, T)
PFPN‐SES55‐001
Cable
Any LGR except
thermocouple
IP65
5 meters cable –
Provided with fast contactor
*If you want to use your own sensor, you have to order a cable and a connector to plug it on the LG.
LGS
Loggers
1/2
Wavelength
IP65
Aluminium
AA (LT)
Battery
References
Interface
Range of measure
PFPN-LGS31-001
Potentiometer
0 to 100%
Impedance: 1 KOhm ... 65 KOhm
PFPN-LGP33-001
Potentiometer 3 inputs
0 to 100%
Impedance: 1 KOhm ... 65 KOhm
PFPN-LGS33-001
0-2.5V
0 … 2.5V
PFPN-LGS34-001
4-20mA
0 ... 20mA
Impedance: 62 Ohm
PFPN-LGA34-001
4-20mA
0 ... 20mA
Impedance: 100 Ohm
Power the connected sensor
PFPN-LGS35-001
0-10V
0 ... 10 Volt
PFPN-LGS36-001
Relay
10 Hz
PFPN-LGS76-001*
Relay
10 Hz
PFPN-LGS37-001
-50/+50mV
-50 … +50mV
PFPN-LGS39-001
Impulse
10 Hz
PFPN-LGS79-001*
Impulse
10 Hz
PFPN-LGSA9-001
Impulse
ATEX zone 2 gas certified
10 Hz
*Supplied on main power. External power supply needed (ref.: PFPN-ADAPT-003)
LGS
Cables and Connectors
References
Type
PFPN-SES55-001
PFPN-SES58-001
Compliance
IP
Characteristics
Cable
LGS33
LGS34 – LGA34
LGS35
LGS36 – LGS76
LGS37
LGS39 – LGS79
LGSA9
IP65
5 meters cable to connect a sensor, provided with fast
contactors.
Cable
LGS31 – LGP33
IP65
5 meters cable to connect a sensor, provided with fast
contactors.
PFPN-CON05-001
Connector
LGS33
LGS34 – LGA34
LGS35
LGS36 – LGS76
LGS37
LGS39 – LGS79
LGSA9
IP65
To directly connect the customer sensor to the LGS.
PFPN-CON08-001
Connector
LGS31 – LGP33
IP65
To directly connect the customer sensor to the LGS.
If you want to use your own sensor, you have to order a cable or a connector to plug it on the LGS.
LGS31
Probes
References
Type
Compliance
IP
Characteristics
LGS31-001
+STY58-002
IP40
Measurement bracket: 0… 10 mm
LGS31-001
IP40
5 meters with temperature gauge integrated and
connector for FISSU-001
LGS31-001
+STY58-003
IP67
Measurement bracket: 0 … 25 mm
LGS31-001
IP67
5 meters with temperature gauge integrated and
connector for FISSU-002
LGS31-001 +
STY58‐004
IP65
Gefran PCM050 crackmeter, female connector
PFPN‐FISSU‐001
Crackmeter
PFPN‐STY58‐002
Associated Cable
PFPN‐FISSU‐002
Crackmeter
PFPN‐STY58‐003
Associated Cable
PFPN‐FISSU‐003
Crackmeter
PFPN‐STY58‐004
Associated Cable
LGS31-001
IP67
5 meters with temperature gauge integrated and
connector for FISSU-003
PFPN‐SES58-001
Cable
LGS31-001
IP65
5 meters cable, to connect any sensor, provided
with fast contactors
PFPN‐STY58-001
Cable
LGS31-001
IP65
5 meters cable, to connect any sensor, provided
with fast contactors and temperature sensor
LGJ
Loggers
1/2
Wavelength
IP65
Aluminium
References
PFPN- LGJ3D-001
Interface
Range of measure
Strain gauges - Full Bridge
(wheatstone bridge)
+/- 50 mV
for a 2.7V excitation
AA (LT)
Battery
Cable and Connector
References
Type
Compliance
IP
Characteristics
PFPN-SES58-001
Cable
LGJ
IP65
5 meters cable to connect a sensor, provided with fast
contactors.
PFPN-CON08-001
Connector
LGJ
IP65
Connector used to connect the sensor of your choice
If you want to use your own sensor, you have to order a cable or a connector to plug it on the LGJ.
LGN
Loggers
1/2
Wavelength
IP66
Aluminium
References
PFPN- LGN45-001
Interface
-5V / +5V
5 inputs
Range of measure
-5V ... +5V
Power supply for the sensor
13.6V
Consu. max : 20mA (per sensor)
C (LT)
Battery
Cable and Connector
References
Type
Compliance
IP
Characteristics
PFPN-SES58-001
Cable
LGN
IP65
5 meters cable to connect a sensor, provided with fast
contactors.
PFPN-CON08-001
Connector
LGN
IP65
Connector used to connect the sensor of your choice
If you want to use your own sensor, you have to order a cable or a connector to plug it on the LGN.
LGW
Loggers
1/2
Wavelength
IP65
Aluminium
AA (LT)
Battery
References
PFPN-LGW31-001
PFPN-LGW32-001
PFPN-LGW33-001
PFPN-LGW34-001
PFPN-LGW35-001
PFPN-LGW75-001*
PFPN-LGW38-001
Range of measure
0 to 3 Volt
0 to 1 Volt
0 to 2 Volt
0 to 10 Volt
0 to 10 Volt
0 to 10 Volt
0 to 5 Volt
Power supply for the sensor
3 Volt / 150 mA
10 Volt
12 Volt / 100 mA
12 Volt
15 Volt
15 Volt
10 Volt / 100 mA
*Supplied on main power. External power supply needed (ref.: PFPN-ADAPT-003)
LGW
Probes and Cables
References
Type
Compliance
IP
Characteristics
PFPN‐PYRAN‐001
Probe
LGW31
IP67
Probe of 5 meters with pyranometer integrated
PFPN‐AIRSP‐001
Probe
LGW38
IP20
Probe of 5 meters for speed of air measure
PFPN‐SES55‐001
Cable
All LGW
IP65
5m cable, to connect any sensor, provided with fast
contactors
tEMPMATE
USB Temperature Recorders
USB
Connection
S1-Tempmate
References
Content
Temperature sensor
PFKI-LTM06-001
Set of 20 USB recorders
Recording cycle : 6 days
-30°C to 70°C ±0.5°C from -20°C to +40°C
± 1°C for other range
IP67
PFKI-LTM15-001
Set of 20 USB recorders
Recording cycle : 15 days
-30°C to 70°C ±0.5°C from -20°C to +40°C
± 1°C for other range
Lithium
Battery
PFKI-LTM90-001
Set of 20 USB recorders
Recording cycle : 90 days
-30°C to 70°C ±0.5°C from -20°C to +40°C
± 1°C for other range
PFPN-TEMM1-001
M1-Tempmate, multi-use USB
Temperature recorder with display
-30°C to 70°C ±0.5°C from -20°C to +40°C
± 1°C for other range
USB
Connection
M1-Tempmate
NEW
IP67
Lithium
Battery
TRK-TRE-TRP
Trackers
References
Internal
Antenna
PFPN-TRK31-001
IP54
PFPN-TRK33-001
1/4
References
Sensors
Shock: -6g .. +6g
Temp.: -10°C ... +60°C ± 0.4°C
Hum.: 0 … 100% rH ±3.0%
Light : 0 ... 220 Lux ± 30 Lux
Shock: -6g .. +6g
Temp.: -40°C ... +85°C ± 0.4°C
Hum.: 0 … 100% rH ±3.0%
Light : 0 ... 220 Lux ± 30 Lux
Operating Temp
Battery
-40°C ... +85°C
A LT
-10°C ... +60°C
Sensors
Operating Temp
PFPN-TRK41-002
Shock: -6g .. +6g
-10°C ... +60°C
Temp.: -10°C ... +60°C ± 0.4°C
Hum.: 0 … 100% rH ±3.0%
Light : 0 ... 220 Lux ± 30 Lux
Same as PFPN-TRK41-001, without antenna
Internal
Antenna
References
Sensors
Operating Temp
IP54
Casing
PFPN-TRE37-001
-40°C ... +60°C
A LT
Battery
PFPN-TRE38-001
Shock: -16g … +16g
Temp.: -40°C ... +85°C±0.3°C
Hum.: 0 to 100% rH ± 1.8%
Shock: -16g … +16g
Temp.: -40°C ... +85°C±0.3°C
Hum.: 0 to 100% rH ± 1.8%
Light : 0 ... 220 Lux ± 30 Lux
Wavelength
IP54
Casing
3 AA
Alkaline
PFPN-TRK41-001
PFPN-TRE35-001
Shock: -16g … +16g
Temp.: -40°C ... +85°C±0.3°C
3 AA Alkaline
-40°C ... +60°C
-40°C ... +60°C
NEW
NEW
Internal
Antenna
IP67
Casing
GPS
References
PFPN-TRP55-001
Sensors and GPS
Shock : -16g .. +16g
Temp.: -10°C ... +60°C ± 0.4°C
GPS Modem accuracy : from 2 to 5m
Ground speed : from 0 to 155 km/h
± 5 km/h
Azimuth : from 0 to 360° ± 3°
Operating Temp
-10°C ... +50°C
With Alkaline batteries
Battery
3 x AA Alkaline
NEW
-40°C ... +60°C
With Lithium batteries
3 x Thionyl Lithium
AA (3.6V) Batteries
BLD
Builders
IP54
Casing
High range
Antenna with
a 5m cable
C LT
Battery
References
Sensors
PFPN-BLR36-001
PFPN-BLR37-001
Temp.: -20°C ... +80°C± 0.3°C
Temp.: -20°C ... +80°C± 0.3°C
Deformation: -1850 ppm to +1850 ppm
for a bridge excitation of 2.7 Volt
RPT
Repeaters
References
Specifications
Case
Antenna
Power supply
PFPN-RPT51-001*
Outdoor radio relay
IP67
Full Wavelength
Solar panel
NEW
*The RPT51 will be available soon. Contact us for more details.
References
Specifications
Case
Antenna
Power supply
PFPN-RPT20-001
Indoor radio relay
IP50
1/2 Wavelength
Conventional
AC Power (supplied)
References
Specifications
Case
Antenna
PFPN-RPT30-001
Outdoor radio relay
IP65
1/2 Wavelength
Power supply
Conventional
AC Power (supplied)
COL
Collectors
References
Specifications
Case
Antenna
Power supply
PFPN-COL11-001
GPRS Collector
IP30
1/2 Wavelength
Conventional
AC Power
PFPN-COL22-001
Ethernet Collector
IP30
Full Wavelength
magnetic foot
cable 4 meters
Conventional
AC Power
PFPN-COL51-001
Outdoor GPRS
Collector
IP67
Full Wavelength
Solar panel
Data Base Hosting
References
Specifications
VAHE-DBASE-001
Fees (Database hosting and WebMonitor)
VAHE-DBASE-012
Data base hosting (4Go Max) & WebMonitor – 12 months
VAHE-DBASE-024
Data base hosting (4Go Max) & WebMonitor – 24months
VAHE-DBASE-036
Data base hosting (4Go Max) & WebMonitor – 36 months
The offer of hosting the
database gives access to the
Newsteo platform. Newsteo is
responsible of hosting the
database client, database
which is linked to a facility
with a Collector or a RF
Monitor Gold software.
Access to the measurements
via WebMonitor (web
application) or DB Monitor.
KEY
For Plc
References
PFPN-KES63-001
PFPN-KES65-002
Link
Rf-to-RS232
Rf-to-RS485
Communication Antenna
protocol
MODBUS
Without Antenna
MODBUS
Without Antenna
IP
IP30
IP30
SOFTWARE
References
Characteristics
PFPN-RFM05-001
RF Monitor for LOM & LOP only, not compliant with other references
Delivered with KEY15-001
Premium: The measurements are stored on the PC, on a local database
PFPN-RFM10-001
RF Monitor with Premium Licence
Delivered with KEY11-001
Premium: The measurements are stored on the PC, on a local database
PFPN-RFM20-001
RF Monitor with Gold Licence
Delivered with KEY12-001
Gold: The measurements are stored on a shared and remote database
PFPN-RFM30-001
RF Monitor Gold with CFR21
Delivered with KEY14-001
PFPN-RFM40-001
RF Monitor Premium with CFR21
Delivered with KEY13-001
PFPN-RFMxx-001 kits composition:
- 1 x PFPN-KEYxx-001 : USB key receiver with license (reference key depending on the ordered kit)
- 1 x PFPN-CDRFM-001 : installation software CD-ROM
- 1 x PFPN-CBUSB-001 : USB Extension cable 0.8 meter
- 1 x PFPN-AIMANT-001 : Wakeup magnet
- 1 x User’s guide
SMS PACKS
References
Characteristics
VAAL-E2SMS-001
First pack 100 credits alert SMS (creation costs included)
VAAL-E2SMS-002
Pack of 100 additional credits alert SMS
VAAL-E2SMS-003
Pack of 1,000 additional credits alert SMS
ANTENNAS
References
Type
Compliancy
PFPN-ANT40-001
Whip ¼ wavelength
KEY – LOG – TRK41
PFPN-ANT41-001
¼ wavelength with ground plane
Cable of 2 meters
KEY – LOG – LGR – LGS – LGW –
RPT20
PFPN-ANT43-001
¼ wavelength with magnetic feet
3 meters cable
COL22
PFPN-ANT20-001
Whip ½ Wavelength, rigid
LGR – LGS – LGW – RPT20
PFPN-ANT20-002
Whip ½ Wavelength, flexible
LOG – KEY
PFPN-ANT11-001
Indoor Full wavelength grounded
Cable of 5 meters
KEY – LOG – LGx - RPT
PFPN-ANT11-002
Indoor Full wavelength grounded
Cable of 10 meters
KEY – LOG – LGx - RPT
Indoor Full wavelength grounded
Cable of 20 meters
Outdoor Full wavelength grounded with Thunder
protection
Cable of 5 meters
Outdoor Full wavelength grounded with Thunder
protection
Cable of 10 meters
Outdoor Full wavelength grounded with Thunder
protection
Cable of 20 meters
KEY – LOG – LGx - RPT
PFPN-ANT11-003
PFPN-ANT13-001
PFPN-ANT13-002
PFPN-ANT13-003
PFPN-ANT97-001
Yagi
Directional range.
PFPN-ANT14-001
Indoor Full wavelength antenna
Cable of 4 meters
PFPN-ANT44-001
Whip ¼ Wavelength –
0 to 90° Rotation
KEY – LGx - RPT
KEY – LGx - RPT
KEY – LGx - RPT
RPT (consult us)
PFPN-ANT44-001
Whip ¼ Wavelength –
0 to 90° Rotation
PFPN-ANT10-001
Whip Full wavelength antenna
All products with SMA base
CHARACTERISATION
Kit For Characterisation Of Climatic
Chambers
Reference
PFKI-CEC09-002
Content
Characteristics
9 x LOM18
High accuracy Mini Logger +/-0.1°C – racco. COFRAC
1 x COL11
GPRS Collector with RFM Gold licence incl. (1/2 wave antenna)
EVALUATION KITS
For Newsteo Products
Devices
Software
Key
Magnet
USB Cable
PFKI-LOG26-001
One LOG26-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
PFKI-LOG22-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
PFKI-TRK31-001
One LOG22-001
One LGR33-001
One Probe STE53-003
One LGR37-001
One Probe STC01-002
One TRK31-001
One RFM10-001
One Key11-001
PFKI-TRE35-001
One TRE35-001
One RFM10-001
One Key11-001
PFKI-BLR37-001
One BLR37-001
One LGS34-001
One cable SES55-001
One LGS35-001
One cable SES55-001
One LGS39-001
One cable SES55-001
One LGSA9-001
One cable SES55-001
One PFPN-KES63-001
One antenna ANT40
One PFPN-KES65-001
One antenna ANT40
One RFM10-001
One Key11-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
PFKI-LGR33-001
PFKI-LGR37-001
PFKI-LGS34-001
PFKI-LGS35-001
PFKI-LGS39-001
PFKI-LGSA9-001
PFKI-KES63-001
PFKI-KES65-001
One CBUSB-001
One AIMANT-001
One CBUSB-001
One CBUSB-001
One PFPN-KES65-001
One antenna ANT11
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
One RFM10-001
One Key11-001
One AIMANT-001
One CBUSB-001
Devices
PFKI-LOM16-001
PFKI-LOM16-002
PFKI-LOM18-001
PFKI-LOM18-002
PFKI-LOP16-001
PFKI-LOP16-002
2 x PFPN-LOM16-001
5 x PFPN-LOM16-001
2 x PFPN-LOM18-001
5 x PFPN-LOM18-001
2 x PFPN-LOP16-001
5 x PFPN-LOP16-001
Software
Key
Magnet
USB Cable
One RFM05-001
One PFPN-KEY15-001
1 x AIMANT-001
One CBUSB-001
2 x AIMANT-001
One RFM05-001
One PFPN-KEY15-001
1 x AIMANT-001
One CBUSB-001
2 x AIMANT-001
One RFM05-001
One PFPN-KEY15-001
1 x AIMANT-001
2 x AIMANT-001
One CBUSB-001
ACCESSORIES
PFPN-CBL05-001
References
Description
Characteristics
Cable
5m extension coax cable SMA. Male-Female.
PFPN-CBL10-001
Cable
10m extension coax cable SMA. Male-Female.
PFPN-CBL20-001
Cable
20m extension coax cable SMA. Male-Female.
PFPN-CBL05-002
Cable
5m extension coax cable SMA. Male to N Male.
PFPN-CBL05-003
Cable
5m extension coax cable SMA. Male (waterproof) to N Male.
PFPN-CBL10-002
Cable
10m extension coax cable SMA. Male to N Male.
PFPN-CDRFM-001
Description
CD-ROM
Characteristics
Additional RF Monitor CD-ROM installer
PFPN-CDRFM-003
CD-ROM
Additional RF Monitor Pharma software
References
Description
USB cable
Characteristics
USB-A Male-Female extender cable 0.8m
PFPN-RLA21-001
References
Description
USB output relay
Characteristics
Active security - 1 relay with 3 poles
PFPN-RLB21-001
USB output relay
Toggle (bistable) - 1 relay with 3 poles
Description
Characteristics
Newsteo magnet to wake-up loggers
References
PFPN-CBUSB-001
References
PFPN-AIMANT-001
Magnet
References
Description
Characteristics
PFPN-LOTPI-013
Battery
Set of 5 batteries 1/2 AA lithium thyonil.
For all products in the LOG range except and LOG36
PFPN-LOTPI-014
Battery
Set of 5 batteries AA Lithium Thionyl
For older generation products without JST connector for battery
connection. For LGR, LGS, LGP33, LOG36
PFPN-LOTPI-007
Battery
Pack of 30 Alkaline LR6 batteries
For TRK31
PFPN-LOTPI-012
Battery
High autonomy set: Set of 10 double batteries AA Lithium Thionyle
(10x2 batteries)
For TRK33
References
Description
Characteristics
PFPN-LOTPI-015
Battery
Set of 5 batteries 1/2 AA lithium thyonil with wire and connector.
For LOM16, LOM18, LOP16
PFPN-LOTPI-016
Battery
Set of 5 batteries AA lithium thyonil with wire and connector.
For LGR, LGS, LGP33, LGJ3D, LOG36
PFPN-LOTPI-017
Battery
Set of 5 spiralcell batteries AA lithium thyonil with wire and connector.
For LGA34, LGW33, LGW34, LGW35
PFPN-LOTPI-011
Battery
High autonomy set: Set of 5 double batteries AA lithium thyonil
(5x2 batteries) with wire and connector.
For LGW31, LGW38 and LGR, LGS, LGP33, LGJ3D, LOG36
References
PFPN-ADAPT-003
PFPN-ADAPT-004
PFPN-ADAPT-005
Description
Conventional external
power supply
Conventional external
power supply
Conventional external
power supply
Characteristics
Power supply with 3 points M8 female plug, to supply products
such as LGS76
Power supply for RPT30
Power supply for RPT2x and COL2x
References
PFPN-PLATE-001
Description
Fixation
PFPN-COV02-001
Protection
References
Description
Characteristics
Fixation base kit for LOG36, supplied with its 2 screws
Protection mécanique pour les loggers en boitier aluminium.
Characteristics
5 meters cable to connect a sensor, provided with fast
contactors.
For LGR, LGS or LGW (compliant with all references
except LGS31, LGP33, LGJ).
5 meters cable to connect a sensor, provided with fast
contactors.
For LGS31, LGP33, LGJ
Connector used to connect the sensor of your choice to
the LGR, LGS or LGW (compliant with all references
except LGS31, LGP33, LGJ).
Mainly used for the thermocouple (LGR37)
PFPN-SES55-001
Cable
PFPN-SES58-001
Cable
PFPN-CON05-001
Connector
PFPN-CON08-001
Connector
Connector used to connect the sensor of your choice to
the LGS31, LGP33, LGJ.
PFPN-CON13-001
Connector
3 points M8 connector, to supply products such as LGS76
Allows to develop its own power supply instead of using
PFPN-ADAPT-003
References
PFPN-THUND-001
Description
Protection
Characteristics
Thunder protection for ANT11
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising