York | EUKC 42 | Residential & VRF 2012

york air-conditioning products
Residential & VRF 2012
At Johnson Controls, we look at buildings in a
way very few others have ever imagined. When
we look at a building, we see beyond the bricks
and mortar. Beyond the steel and glass. We see
a bigger picture. We see the power of the human
enterprise.
That’s why we create buildings and
environments that help people achieve – and
that give buildings, businesses and people every
opportunity to reach their full potential.
york air-conditioning products
Residential & VRF
Air-conditioning solutions
Every market is unique in air-conditioning
requirements. In this catalogue our customers will
be able to select the different options for residential
market and VRF solutions for Light-Commercial
market.
MINISPLIT SOLUTIONS
•
•
•
•
•
•
•
•
•
•
•
•
High Wall inverter
Multisplit inverter
Console inverter
Floor/ceiling inverter
Cassette inverter
Blower inverter
High Wall on/off
High Wall multisplit on/off
Floor/ceiling on/off
Cassette on/off
Blower on/off
Window unit
Johnson Controls wants to offer all the possible
solutions for different building design and technical
requirements, and the air-conditioning is an important
part of those global solutions.
04/05
The majority of our products are already rated as Class
A for Energy Efficiency, in order to guarantee a high
level of comfort.
According to the market necessities our customers
can find the best solution in our wide product range
depending on the building characteristics.
VRF SOLUTIONS (Outdoor units)
• Capacities from 10 to 180 kW
• Operating range of nominal power
(10% - 100 %)
• Digital Scroll Technology
• Low noise levels
• High performance
• Flexible and quickly installation
VRF SOLUTIONS (Indoor units)
•
•
•
•
•
•
High Wall
Cassette
Convertible console floor/ceiling
Floor standing
Floor standing concealed
Blower
york air-conditioning products
Catalogue Content
Pag.
Split Systems
High wall High Efficiency Inverter - NEW
YWHJZH 09 to 24
20
High wall Inverter - NEW
YRHJZH 09 to 24
22
High wall Inverter
EVHC-D 09 to 24
24
Multi Inverter “Free Indoor Units” - NEW
ERJC 18 to 42
26
Console Inverter
ECHC-D 09 to 18
30
Floor/Ceiling Inverter
EOHC-D 09 to 60-R
32
Cassette Inverter
EKHC-D 12 to 42-R
34
Blower Inverter
EUHC-D 09 to 60-R
36
High wall On/Off - NEW
YVHFZH 09 to 24
40
High wall On/Off
EAHC 09 to 24 FS-R
42
High wall Multi split - NEW
YEHNZH 18 to 24 (2x1)
44
Floor/Ceiling
EOHC 09 to 48 FS
46
Cassette
EKHC 12 to 48 FS
48
Blower
EUHC 12 to 60 FT
50
Window unit
Y8USE 9 to 24
52
YDMH 100, 140, 280, 335, 400, 450 C
58
VRF Systems
YDS-C Variable refrigerant flow system
06/07
Cooling capacity kW
1.0
2.5 - 7.0
2.6 - 6.4
2.4 - 6.0
5.0 - 11.6
2.7 - 5.3
3.0 - 16.0
3.4 - 11.0
2.7 - 15.8
2.7 - 6.3
2.5 - 6.3
5.6 - 7.0
2.5 - 13.2
3.5 - 13.2
3.5 - 16.0
2.8 - 6.2
10 - 180
5.0
10.0
20.0
50.0
100.0
200.0
york air-conditioning products
08/09
Minisplit
Inverter Systems
high wall units
multisplits free combination
console, cassette, floor/ceiling &
blower units
york air-conditioning products
10/11
efficient comfort
high efficiency inverter range
The High Wall inverter air conditioners have been designed thinking about comfort and sustainability. Comfort as the ultimate
technology of DC Inverter compressor installed in these units is able to achieve performances of 4.25 COP in heating and
cooling mode, the temperature variations in the room are minimized and the noise level is lower. The active carbon electrostatic
filter improves the air quality and thanks to the motorized louver system, the air is distributed equally in the room.
Sustainable because the high efficiency of the unit results in a very low energy consumption, one of the most efficient in the
market, the materials used are recyclable and free of hazardous substances, all together makes this unit the appropriate choice
for conditioning your home.
york air-conditioning products
12/13
i n v e rt e r syst e m
h i g h e r e f f i c i e n cy a n d c o m f o rt
conventional system
inverter system
Compressor
capacity
Indoor
temperature
Desired
temperature
44%
energy
saving
energy
savings
Conventional
air conditioning
DC INVERTER
air conditioning
DC Inverter technology regulates the frequency of the compressor which results in many advantages:
• Energy saving by avoiding consumption peaks of the compressor compared to an on-off system. Inverter compressors reduce
the frequency and therefore increase the efficiency.
• The variations of the temperature in the room are reduced improving the comfort.
• The setting temperature is achieved faster thanks to the flexibility of the system which allows reaching even 30% more of
the nominal capacity.
• The overall performance is more uniform and silent.
york air-conditioning products
14/15
f i lt e r o pt i o n s
f o r a c l e a n a n d h e a lt h y a i r
STANDARD FILTER
SILVER ION FILTER
PLASMA FILTER
These filters prevent the
bigger dust particules to
enter the room by creating a
barrier against dirtyness and
insects.
The Silver ion filter kills
bacteria in the air and controls
the growth of microbes,
such as bacteria, virus, fungi,
and spores, by destroying
their inner configuration and
absorbing the cells elements.
The Plasma Dust Collector
can generate an ionization
zone. The air is converted to
plasma as it passes the high
voltage ion generator.
95% of the dust, smoke and
pollen particles are attracted
to the electrostatic filter.
DRY MOULD PROOF
Turn off the unit that contains this function when it is cooling or drying,
indoor fan would still operate in low speed to dry the inner components
and parts. This action can remain unit inside clean and dry, prevent
mould growing and olor.
CARBON
ELECTROSTATIC
FILTER
Active Carbon Filter eliminates
certain kinds of odors such
as ammonia (NH3) and
deactivates harmful chemical
gas such as formaldehyde
(HCHO).
york air-conditioning products
Range Capacities
2.0
High Wall
High Efficien.
Inverter
3.0
2.5
4.0
3.5
2.5
4.5
5.0
6.0
5.5
3.5
6.5
7.0
5.3
7.5
8.0
8.5
9.0
7.0
Page 20
High Wall
Inverter
2.6
3.5
5.4
6.4
Page 22
High Wall
Inverter
2.4
3.5
5.3
6.0
Page 24
5.0
Multi
Inverter
ERJC
7.0 7.1
8.0
9.0
Page 26
2.7
Console
Inverter
3.6
5.3
Page 30
3.0
Floor
Ceiling
Inverter
3.4
5.3
6.8
8.8
Page 32
3.4
Cassette
Inverter
5.2
7.0
8.8
Page 34
Blower
Inverter
2.7
3.4
2.7
3.4
6.8
5.3
8.0
Page 36
High Wall
On/Off
5.1
6.3
Page 40
High Wall
On/Off
2.5
3.1
4.6
6.2
Page 42
5.6
High Wall
Multi Split
6.3
7.0
Page 44
Floor
Ceiling
2.5
3.5
5.2
7.2
Page 46
3.5
Cassette
5.3
7.0
Page 48
3.5
Blower
5.2
7.0
Page 50
Window
Page 52
2.8
3.8
5.3
6.2
9.5
10.0
10.0
10.5
11.0
11.5
12.0
12.5
13.0
14.0
13.5
14.5
15.0
15.5
16.0
11.6
10.6
10.1
10.1
11.8
13.6
11.0
10.6
13.8
10.0
12.0
13.2
10.0
12.0
13.2
10.2
16.0
12.2
13.2
15.8
16.0
16.5
17.0
17.5
18.0
18.5
kW
Minisplit Systems
16/17
york air-conditioning products
Main Features
A
More efficient
A
B
C
D
E
F
G
Less efficient
EU Energy Label A Class
Heater Cable
With the powerful compressor and optimized
refrigerant, the EER can reach EU Energy Label
A Class (over 3.2 w/w) or B Class (over 3.0 w/w),
greatly reducing the power consumption.
Heater cable prevents ice forming on the outdoor
unit. Specially indicated in heat pump mode and
low ambient temperature conditions. A thermostat
regulates the activation of the heater.
Auto-Restart Function
Turbo Mode
When the power supply is interrupted and then
restored, the air conditioners automatically restore
the previous function setting.
Press the Turbo button and the A/C will reach the
preset temperature in the shortest time.
Two-direction Air Vane Tech
Condensate pump
With special structural design and microcomputer
control, York air conditioners employs a unique bidirectional rotary air vane technology.
Made up of a pump and a remote detection unit.
The pump absorbs the condensates from the
indoor unit and sends it to the draining pipes.
Low Ambient Kit
Dehumidification
The air conditioning unit can operate in cooling
mode at low ambient temperature conditions.
The kit is suitable for special applications such as
computer and power station control rooms where
cooling is required even in the winter months.
Independent dehumidification function is usually
used in rainy days in springtime or damps areas. The
unit will alternately operate in cooling mode or fan
only mode, which assures strong dehumidification
while not lowering room temperature.
Sleep Mode
Bio Filter
With Spleep Mode, the air conditioner’s set
temperature will automatically increase (cooling)
or decrease (heating) 1°C per hour for the first two
hours then hold steady for the next 5 hours after
which the air conditioner will stop operation. With
the sleep mode function can maintain the most
confortable temperature and save energy.
Bio Filter consists of a specialized biological
enzyme and Eco Filter. The Eco Filter catches
very small airborne dust particles and neurilities
bacteria, fungi and microbes. Biological enzyme
eliminates bacteria by dissolving their cell wall
thus eliminating the problem of re-pollution seen
in traditional air conditioners.
18/19
Minisplit Systems
Main Features
Active Carbon Electrostatic Filter
Ionizer
Active Carbon Filter eliminates certain kinds of
odors such as ammonia (NH3) and deactivates
harmful chemical gas such as formaldehyde (HCHO).
By forming positive positions on the filter surface,
Electrostatic Fiber Filter traps small dust particles,
smoke and pet fur to prevent allergic reactions.
Ionizer brings refreshing air into the home. Anions
can stimulate the blood circulation system,
improve lung function and effectively prevent
respiratory passage illnesses (sutch as asthma and
pneumonia).
Plasma Filter
Valve Protection Cover
It protects the service valves and prevents water
from dripping.
The Plasma Dust Collector can generate an
ionization zone. The air is converted to plasma as
it passes the high voltage ion generator. 95% of the
dust, smoke and pollen particles are attracted to
the electrostatic filter.
Anti-Rust Cabinet
Made from electrolytic zinc steel sheet and antirust coated components. York’s outdoor units are
rust free even in coastal regions.
Iconography
Infrared
control
Wired
control
Infrared
or Wired
control
Dry
mode
Sleep
mode
Timer
Auto
Sweep
Auto
Restart
Turbo
mode
Thin
profile
Quiet
4 Way
Air Flow
Floor/
Ceiling
Ducted
Installation
Air
Filter
Low
Ambient
Kit
york air-conditioning products
High Wall High Efficiency Inverter
YWHJZH 09 to 24
A complete range from 2.5 kW to 6.4 kW
NEW
Features
Remote controller
• DC Inverter compressor
• Low noise levels
• Ultra high EER&COP, up to 5.01/5.21
• Multi louvers design for faster heating
• 1W standby
• Quiet design with low noise to 21dB(A)
• 8°C heating
• 3 sleep modes/curves
• Intelligent defrosting
• LED display
• Overlong distance air flow
• Blue crystal fin evaporator
• 7 fan speeds with turbo cooling
• 3D-airflow with auto horizontal airflow
(Left/Right)
• Low Ambient Kit
• Heater cable
• Gold fin condenser
• Service valve protection cover
• Wireless
• I FEEL function
• 5 operation modes(Cool/
Heat/Auto/Dry/Fan)
• 5 Fan speeds selection
• Quiet/sleep button
• Air flow direction setting
• LCD display
• Turbo mode
• Room temperature setting
• Lock Button Function
Minisplit Systems
20/21
High Wall High Efficiency Inverter
YWHJZH 09 to 24
Technical features
Set reference
YWHJZH
Indoor unit
Sizes
YWHJXH-09
YWHJXH-12
YWHJXH-18
YWHJXH-24
Outdoor unit
Sizes
YWHJYH-09
YWHJYH-12
YWHJYH-18
YWHJYH-24
Cooling capacity
kW
2.5 (0.7 - 3.8)
3.5 (0.7 - 4.5)
5.3 (0.8 - 6.7)
7.0 (1.3 - 8.7)
Heating capacity
kW
2.7 (0.7 - 4.0)
3.6 (0.7 - 5.5)
5.6 (1.0 - 7.3)
7.6 (1.2 - 10.0)
Compressor
Type
2.00
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
kW
0.60
0.83
1.45
heating
kW
0.66
0.83
1.47
2.11
4.16
4.21
3.65
3.50
EER
COP
Energy Class
230 / 1 / 50 + E
cooling
4.16
4.00
3.81
3.61
cooling
A
A
A
A
heating
A
A
A
A
Indoor airflow (L / M / H)
m3/h
330 / 370 / 420
410 / 530 / 670
630 / 710 / 870
700 / 800 / 900
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
24 / 28 / 32
24 / 32 / 36
36 / 39 / 41
41 / 43 / 45
dB(A)
41
43
49
51
H (mm)
292
292
315
326
W (mm)
806
866
1 017
1 178
D (mm)
206
206
234
264
H (mm)
540
596
700
790
W (mm)
848
899
955
980
D (mm)
320
378
396
427
Indoor unit
kg
10.5
11
15
18
Outdoor unit
kg
36
43
50
68
Gas
3/8”
3/8”
5/8”
5/8”
Liquid
1/4”
1/4”
1/4”
1/4”
1 700
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
740
1 000
1 160
Length
m
15
20
25
25
Height
m
10
10
10
10
18
24
Operating limit - cooling mode
min./max.
+10°C / +48°C
Operating limit - heating mode
min./max.
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall Inverter
YRHJZH 09 to 24
A complete range from 2.6 kW to 6.4 kW
NEW
Features
Remote controller
• DC Inverter compressor
• Low noise levels
• High EER&COP, Class A
• 1W standby
• LED display
• Automatic restart
• Automatic clean
• Intelligent defrosting
• Confortable sleep mode
• Cold air prevention
• Self-diagnosis
• Service valve protection cover
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes(Cool/
Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Air flow direction setting
• LCD display
• Turbo mode
• Lock Button Function
Minisplit Systems
22/23
High Wall Inverter
YRHJZH 09 to 24
Technical features
Set reference
YRHJZH
Indoor unit
Sizes
YRHJXH-09
YRHJXH-12
YRHJXH-18
YRHJXH-24
Outdoor unit
Sizes
YRHJYH-09
YRHJYH-12
YRHJYH-18
YRHJYH-24
Cooling capacity
kW
2.6 (0.4 - 3.2)
3.5 (0.6 - 4.0)
5.4 (1.0 - 6.4)
6.4 (1.4 - 7.0)
Heating capacity
kW
3.5 (0.4 - 4.1)
4.0 (0.6 - 5.1)
5.7 (1.0 - 7.1)
6.7 (1.2 - 8.0)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.80
1.10
1.70
2.00
heating
kW
0.99
1.14
1.70
1.90
EER
3.30
3.25
3.23
3.22
COP
3.65
3.63
3.61
3.62
cooling
A
A
A
A
heating
A
A
A
A
Power input
Energy Class
Indoor airflow (L / M / H)
m3/h
280 / 370 / 520
300 / 410 / 560
460 / 560 / 680
550 / 700 / 800
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
24 / 30 / 36
25 / 31 / 37
32 / 37 / 40
34 / 39 / 44
dB(A)
34
35
42
44
H (mm)
283
283
380
319
W (mm)
770
770
945
1 008
D (mm)
201
201
295
221
H (mm)
550
550
700
700
W (mm)
658
658
955
955
D (mm)
275
275
396
396
Indoor
Dimensions
Outdoor
Net weight
Indoor unit
kg
8
9
12
15
Outdoor unit
kg
28
30
52
55
Gas
3/8”
3/8”
1/2”
1/2”
Liquid
1/4”
1/4”
1/4”
1/4”
1 700
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
740
1 000
1 160
Length
m
15
15
25
25
Height
m
5
5
10
10
18
24
Operating limit - cooling mode
min./max.
+10°C / +48°C
Operating limit - heating mode
min./max.
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall Inverter
EVHC-D 09 to 24
A complete range from 2.4 kW to 6.0 kW
Features
Remote controller
• DC Inverter compressor
• Low noise levels
• Dry mould proof
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
• Lock button function
Minisplit Systems
24/25
High Wall Inverter
EVHC-D 09 to 24
Technical features
Set reference
EVHC
Indoor unit
Sizes
EVKC-09DS
EVKC-12DS
EVKC-18DS
EVKC-24DS
Outdoor unit
Sizes
EVJC-09DS
EVJC-12DS
EVJC-18DS
EVJC-24DS
Cooling capacity
kW
2.4 (0.6 - 3.2)
3.5 (0.5 - 3.9)
5.3 (1.3 - 6.2)
6.0 (1.4 - 6.8)
Heating capacity
kW
2.8 (0.8 - 3.6)
3.9 (0.9 - 4.4)
5.8 (1.3 - 6.3)
6.8 (1.3 - 8.0)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.78
1.08
1.70
1.96
heating
kW
0.78
1.12
1.71
2.05
EER
3.21
3.24
3.21
3.21
COP
3.61
3.61
3.41
3.41
cooling
A
A
A
A
heating
A
A
B
B
Power input
Energy Class
Indoor airflow (high speed)
m3/h
500
500
850
900
Sound pressure Indoor (L/M/H)
at 1 m
Outdoor
dB(A)
32 / 35 / 37
33 / 36 / 39
38 / 42 / 45
40 / 43 / 48
dB(A)
50
52
53
54
H (mm)
265
275
298
330
W (mm)
790
845
940
1 060
D (mm)
170
180
200
208
H (mm)
540
540
700
700
Indoor
Dimensions
Outdoor
Net weight
W (mm)
776
776
890
890
D (mm)
320
320
340
340
Indoor unit
kg
9
11
13
16
Outdoor unit
kg
27
29
47
50
Gas
3/8”
3/8”
1/2”
1/2”
Liquid
1/4”
1/4”
1/4”
1/4”
1 400
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
730
950
1 100
Length
m
15
20
25
25
Height
m
10
10
10
10
18
24
Operating limit - cooling mode
min./max.
+18°C / +50°C
Operating limit - heating mode
min./max.
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Cold Plasma filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Multi Inverter Free Indoor Units
ERJC 18 to 42
A complete range from 5.0 kW to 11.6 kW
NEW
ERJC 18-22 (2x1)
Indoor units
ERJC 24 (3x1) / ERJC 28 (4x1) / ERJC 36 (4x1)
Features
Remote controller
• DC inverter compressor
• Classe A cooling and heating
• Free match indoor/outdoor
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• Air flow direction setting
• LCD display
Minisplit Systems
26/27
Multi Inverter Free Indoor Units
ERJC 18 to 42
Technical features Outdoor units
Model
Outdoor units
ERJC-R
Sizes
number
Indoor units
Cooling capacity
kW
Heating capacity
kW
Compressor
Type (Nb)
Refrigerant
Location of expansion device
Power supply
V/Ph/Hz
cooling
kW
Power input
heating
kW
EER
COP
cooling
Energy Class
heating
Airflow (outdoor unit)
m3/h
Sound pressure level
dB(A)
Dimensions outdoor unit H / W / D mm
Net weight outdoor unit
kg
Type of connection
Piping
Gas
Diameter
Liquid
Length
m
Max pipe run *
Height
m
Refrigerant charge
g
Operating limits - cooling mode
min/max
Operating limits - heating mode
min/max
18
22
2 indoor units
5.0 (2.1 - 6.2)
5.6 (2.5 - 6.7)
2 indoor units
7.0 (2.7 - 8.2)
7.7 (3.5 - 9.5)
1.55
1.54
3.23
3.64
A
A
2 600
50
596 / 899 / 378
43
2.18
2.26
3.21
3.41
A
B
3 300
52
700 / 955 / 396
59
3/8”
1/4”
15
10
1 350
3/8”
1/4”
15
10
2 400
24
* Each indoor unit
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge (each indoor unit)
Manufacturer reserves the rights to change specifications without prior notice.
28
3 indoor units
4 indoor units
7.1 (2.2 - 10.0)
8.0 (2.2 - 10.0)
8.5 (3.6 - 11.0)
9.3 (2.8 - 11.0)
Rotary Inverter (1)
R410A
Outdoor unit
230 / 1 / 50 + E
2.20
2.48
2.35
2.55
3.21
3.23
3.62
3.63
A
A
A
A
3 300
3 300
52
53
700 / 955 / 396
700 / 955 / 396
59
60
Flare
3/8”
3/8”
1/4”
1/4”
15
15
10
10
2 200
2 200
-5°C / +43°C
-10°C / +24°C
36
42
4 indoor units
9.8 (2.5 - 14.7)
11.0 (2.8 - 16.5)
5 indoor units
11.6 (2.4 - 17.4)
13.0 (2.7 - 19.5)
3.03
3.01
3.23
3.65
A
A
3 300
54
1 100 / 1 015 / 440
78
3.59
3.54
3.23
3.67
A
A
3 300
54
1 100 / 1 015 / 440
79
3/8”
1/4”
15
10
4 300
3/8”
1/4”
15
10
4 800
york air-conditioning products
Indoor units technical features
• Active carbon electrostatic filter
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
ERKC
12
3.5
3.8
230 / 1 / 50 + E
630
34 / 32 / 30
275 / 845 / 180
10
Flare
3/8”
1/4”
09
2.6
2.8
500
34 / 31 / 28
265 / 790 / 170
9
3/8”
1/4”
18
5.3
5.8
850
43 / 40 / 36
298 / 940 / 200
13
1/2”
1/4”
• Console
• Automatic air sweep
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/M/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
ECKC
12
3.5
3.8
230 / 1 / 50 + E
550
40 / 37 / 32
600 / 700 / 215
15
Flare
3/8”
1/4”
09
2.6
2.8
480
38 / 33 / 26
600 / 700 / 215
15
3/8”
1/4”
18
5.3
5.8
650
46 / 41 / 35
600 / 700 / 215
15
1/2”
1/4”
• Floor/Ceiling
• Automatic air sweep
EOKC
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09
2.5
2.8
12
3.5
3.9
650
40 / 36
700 / 1 220 / 225
40
3/8”
1/4”
18
5.0
5.5
230 / 1 / 50 + E
650
950
40 / 36
45 / 40
700 / 1 220 / 225
700 / 1 220 / 225
40
40
Flare
1/2”
1/2”
1/4”
1/4”
24
7.1
8.0
1 250
48 / 40
700 / 1 220 / 245
45
5/8”
3/8”
• Condensate pump included
• 600 x 600 standard size
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions unit
Dimensions panel
Net weight unit
Net weight panel
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
High speed
dB(A)
H/W/D
mm
H/W/D
mm
kg
kg
Type of connection
Gas
Diameter
Liquid
12
3.5
4.0
600
46
230 / 570 / 570
50 / 650 / 650
18
6.5
3/8”
1/4”
EKKC
18
4.5
5.0
230 / 1 / 50 + E
600
46
230 / 570 / 570
50 / 650 / 650
18
6.5
Flare
1/2”
1/4”
24
7.1
8.0
1 180
39
240 / 840 / 840
60 / 950 / 950
30
6.5
5/8”
3/8”
• Slim size
• Air filter included
• Wired control included
EUKC
Indoor units
Cooling capacity
Heating capacity
Power supply
Indoor airflow
Sound pressure level
Dimensions
Net Weight
Piping
Sizes
kW
kW
V/Ph/Hz
m3/h
H/L
dB(A)
H/W/D
mm
kg
Type of connection
Gas
Diameter
Liquid
09
2.5
2.8
12
3.5
3.9
450
37 / 31
200 / 700 / 615
22
3/8”
1/4”
18
5.0
5.5
24
7.1
8.0
230 / 1 / 50 + E
500
700
39 / 32
40 / 33
200 / 700 / 615
200 / 900 / 615
24
25
Flare
1/2”
1/2”
1/4”
1/4”
1 000
42 / 34
200 / 1 100 / 615
29
5/8”
3/8”
Indoor unit combinations
ERJC 18 (2x1)
ERJC 22 (2x1)
Number connecting units
2x1
Number connecting units
2x1
9+9
9+12
9+9
9+12
12+12
9+18
12+18
18+18
ERJC 24 (3x1)
Number connecting units
2x1
3x1
9+9
9+12
12+12
9+18
12+18
9+9+9
9+9+12
9+12+12
9+9+18
12+12+12
9+12+18
12+12+18
9+18+18
ERJC 28 (4x1)
Number connecting units
3x1
2x1
9+9
9+12
12+12
9+18
12+18
18+18
9+9+9
9+9+12
9+12+12
12+12+12
4x1
9+9+18
9+12+18
12+12+18
9+18+18
9+9+9+9
9+9+9+12
9+9+9+18
9+9+12+12
9+9+12+18
9+12+12+12
9+12+12+18
9+9+18+18
12+12+12+12
ERJC 36 (4x1)
Number connecting units
3x1
2x1
9+9
9+12
12+12
9+18
12+18
18+18
9+24
12+24
18+24
24+24
9+9+9
9+9+12
9+12+12
9+9+18
12+12+12
9+12+18
12+12+18
9+18+18
18+18+18
4x1
9+9+24
9+12+24
9+18+24
9+24+24
12+12+24
12+18+24
12+24+24
18+18+24
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
9+9+12+12
9+9+12+18
9+9+12+24
9+12+12+12
9+12+12+18
9+12+12+24
9+9+18+18
9+9+18+24
9+12+18+18
9+12+18+24
12+12+12+12
12+12+12+18
12+12+12+24
12+12+18+18
ERJC 42 (5x1)
Number connecting units
2x1
9+9
9+12
12+12
9+18
12+18
18+18
9+24
12+24
18+24
24+24
3x1
9+9+9
9+9+12
9+12+12
9+9+18
12+12+12
9+12+18
12+12+18
9+18+18
18+18+18
9+9+24
4x1
9+12+24
9+18+24
9+24+24
12+12+24
12+18+24
12+24+24
18+18+24
9+9+9+9
9+9+9+12
9+9+9+18
9+9+9+24
9+9+12+12
9+9+12+18
9+9+12+24
9+12+12+12
9+12+12+18
9+12+12+24
5x1
9+9+18+18
9+9+18+24
9+12+18+18
9+12+18+24
12+12+12+12
12+12+12+18
12+12+12+24
12+12+18+18
9+9+9+9+9
9+9+9+9+12
9+9+9+9+18
9+9+9+9+24
9+9+9+12+12
9+9+9+12+18
9+9+9+12+24
9+9+9+18+18
Minisplit Systems
28/29
york air-conditioning products
Console Inverter
ECHC-D 09 to 18
A complete range from 2.7 kW to 5.3 kW
Features
Remote controller
• Inverter DC compressor
• Air outlet at top or bottom
• 7 fan speeds
• 8°C Heating mode
• Horizontal and vertical
air sweep function
• Wide angle air distribution
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• 7 fan speeds
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
30/31
Console Inverter
ECHC-D 09 to 18
Technical features
Set reference
ECHC-D
Indoor unit
Sizes
ECKC 09 DS
ECKC 12 DS
ECKC 18 DS
Outdoor unit
Sizes
ECJC 09 DS
ECJC 12 DS
ECJC 18 DS
Cooling capacity
kW
2.7 (0.5 - 3.2)
3.6 (0.6 - 4.0)
5.3 (0.9 - 5.6)
Heating capacity
kW
3.3 (0.5 - 3.8)
4.0 (0.6 - 4.7)
5.5 (0.9 - 6.6)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
kW
0.80
1.13
heating
kW
0.94
1.12
1.56
3.42
3.23
3.26
EER
3.61
3.63
3.62
A
A
A
heating
A
A
A
m3/h
430 / 370 / 280
520 / 440 / 360
620 / 500 / 410
Indoor (H/M/L)
dB(A)
38 / 33 / 25
40 / 37 / 32
46 / 41 / 35
Outdoor
dB(A)
51
51
56
H (mm)
600
600
600
700
Indoor airflow (H/M/L)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
W (mm)
700
700
D (mm)
215
215
215
H (mm)
540
540
700
W (mm)
848
848
955
D (mm)
320
320
396
Indoor unit
kg
15
15
15
Outdoor unit
kg
33
33
49
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
1.62
cooling
COP
Energy Class
230 / 1 / 50
cooling
Flare
Gas
3/8”
3/8”
1/2”
Liquid
1/4”
1/4”
1/4”
1 230
g
1 000
1 050
Length
m
15
15
25
Height
m
10
10
10
Operating limits - cooling mode
min/max
+10°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Floor/Ceiling Inverter
EOHC-D 09 to 60 R
A complete range from 3.0 kW to 16.0 kW
Features
Remote controller
• Inverter DC compressor
• Air filter included
• Convertible - floor or ceiling
• Horizontal and vertical
air sweep function
• Wide angle air distribution
• Low Ambient Kit (optional)
• Slim profile - flush mounting
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
32/33
Floor/Ceiling Inverter
EOHC-D 09 to 60 R
Technical features
Set reference
EOHC-D-R
Sizes
EOKC 09 DS EOKC 12 DS EOKC 18 DS EOKC 24 DS EOKC 30 DS EOKC 36 DS EOKC 42 DS EOKC 48 DS EOKC 60 DS
Outdoor unit
Sizes
ENJC 09 DT ENJC 12 DT ENJC 18 DT ENJC 24 DT ENJC 30 DT ENJC 36 DT ENJC 42 DT ENJC 48 DT ENJC 60 DT
Cooling capacity
kW
3.0 (1.6-3.5)
3.4 (1.6-3.6)
5.3 (1.3-5.5)
6.8 (3.0-7.8)
8.8 (3.1-9.0)
10.6 (3.5-13.0) 11.8 (3.5-13.0) 13.6 (5.0-14.3) 16.0 (4.0-16.5)
Heating capacity
kW
3.0 (1.4-3.8)
3.8 (1.4-4.1)
6.2 (1.5-6.6)
8.0 (2.4-8.5)
9.3 (2.7-9.9)
11.9 (3.5-12.5) 12.6 (3.5-14.2) 15.9 (5.3-18.4) 17.5 (4.5-18.3)
Compressor
Type
Indoor unit
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
400 / 3 / 50
cooling
kW
0.85
1.05
1.65
2.19
2.75
3.26
3.70
4.20
5.00
heating
kW
0.75
0.92
1.70
2.22
2.64
3.16
3.30
4.40
4.86
EER
3.50
3.21
3.21
3.21
3.21
3.21
3.21
3.21
3.21
COP
4.00
4.10
3.61
3.61
3.61
3.61
3.91
3.75
3.61
cooling
A
A
A
A
A
A
A
A
A
heating
A
A
A
A
A
A
A
A
A
m3/h
650/550/450
700/600/500
900/800/700
Indoor (H/M/L)
dB(A)
39 / 37 / 35
39 / 37 / 35
45 / 42 / 39
52 / 49 / 46
50 / 48 / 46
54 / 51 / 48
54 / 51 / 48
58 / 55 / 52
Outdoor
dB(A)
53
54
57
59
59
61
61
61
63
H (mm)
700
700
700
700
700
700
700
700
700
W (mm)
1 220
1 220
1 220
1 220
1 420
1 420
1 420
1 700
1 700
D (mm)
225
225
225
225
245
245
245
245
245
H (mm)
540
540
700
790
790
1 100
1 100
1 365
1 365
Power input
Energy Class
Indoor airflow (H/M/L)
Sound pressure
at 1 m
Indoor
Dimensions
776
776
955
980
980
1 107
1 107
1 085
1 085
D (mm)
320
320
396
427
427
440
440
427
427
Indoor unit
kg
40
40
42
43
51
53
55
64
65
Outdoor unit
kg
28
30
48
65
68
86
90
122
127
Gas
3/8”
3/8”
1/2”
5/8”
5/8”
5/8”
5/8”
5/8”
3/4”
Liquid
1/4”
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
g
1 200
1 350
1 400
2 400
2 600
3 500
3 800
4 300
5 500
Length
m
20
20
20
30
30
30
50
50
50
Height
m
15
15
15
15
15
15
30
30
30
36
42
48
60
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
58 / 55 / 52
W (mm)
Outdoor
Net weight
1200/1050/900 1600/1450/1300 2000/1630/1520 2000/1630/1520 2300/2100/1900 2300/2100/1900
Flare
Operating limits - cooling mode
min/max
-10°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Sizes 36 to 48: Values for single phase models
Accessories
Sizes
09
12
18
24
30
Weekly timer
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Cassette Inverter
EKHC-D 12 to 42 R
A complete range from 3.4 kW to 11.0 kW
Features
Remote controller
• Inverter DC compressor
• Air filter included
• Condensate pump standard
• Fresh air intake for sizes 24 to 42
• Auto restart
• Low Ambient Kit (optional)
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
34/35
Cassette Inverter
EKHC-D 12 to 42 R
Technical features
Set reference
EKHC-D-R
Indoor unit
Sizes
EKKC 12 DS
EKKC 18 DS
EKKC 24 DS
EKKC 30 DS
EKKC 36 DS
Outdoor unit
Sizes
ENJC 12 DT
ENJC 18 DT
ENJC 24 DT
ENJC 30 DT
ENJC 36 DT
EKKC 42 DS
ENJC 42 DT
Cooling capacity
kW
3.4 (1.6 - 3.6)
5.2 (1.9 - 5.5)
7.0 (2.4 - 8.3)
8.8 (3.0 - 9.1)
10.1 (3.0 - 11.5)
11.0 (3.5 - 13.0)
Heating capacity
kW
3.6 (1.6 - 4.0)
6.1 (1.5 - 6.6)
8.7 (3.1 - 9.4)
9.2 (2.5 - 9.9)
11.0 (3.5 - 12.8)
12.0 (3.8 - 14.5)
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
Cooling
kW
1.03
1.65
2.19
2.75
3.20
3.30
Heating
kW
1.02
1.70
2.40
2.64
3.00
3.30
EER
3.22
3.21
3.21
3.21
3.21
3.22
COP
3.61
3.61
3.61
3.61
3.61
3.61
Cooling
A
A
A
A
A
A
Heating
A
A
A
A
A
A
1660 / 1570 / 1500
1660 / 1570 / 1500
1660 / 1570 / 1500
53 / 51 / 48
Power input
Energy Class
m3/h
550 / 450 / 350
Indoor (H/M/L)
dB(A)
47 / 45 / 42
47 / 45 / 43
51 / 49 / 48
53 / 51 / 48
53 / 51 / 48
Outdoor
dB(A)
54
57
59
59
61
61
H (mm)
230
240
240
320
320
320
Indoor airflow (H/M/L)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
1180 / 1080 / 1000 1400 / 1270 / 1170
W (mm)
600
840
840
840
840
840
D (mm)
600
840
840
840
840
840
H (mm)
540
700
790
790
1 100
1 100
W (mm)
776
955
980
980
1 107
1 107
D (mm)
320
396
427
427
440
440
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
Panel H / W / D
mm
50 / 650 / 650
Indoor unit
kg
20
27
27
32
32
38
Outdoor unit
kg
30
48
65
68
86
90
Gas
3/8”
1/2”
5/8”
5/8”
5/8”
5/8”
Liquid
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3 800
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
1 350
1 400
2 400
2 600
3 500
Length
m
20
20
30
30
30
50
Height
m
15
15
15
15
15
30
30
36
42
Operating limits - cooling mode
min/max
-10°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Sizes 36 and 42: values for single phase models
Accessories
Sizes
12
18
24
Weekly timer
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Blower Inverter
EUHC-D 09 to 60 R
A complete range from 2.7 kW to 15.8 kW
Features
Wired control
• Inverter DC compressor
• Air filter included
• Condensate pump optional
• Fresh air intake
• Indoor unit with centrifugal fan
• Large distances between indoor
and outdoor units
• Indoor units with high pressure
• Quiet operation
• Wired control
• Infrared remote control
• Low Ambient Kit (optional)
• Blue fin protection (indoor and
outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Remote controller
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• Air flow direction setting
• LCD display
Minisplit Systems
36/37
Blower Inverter
EUHC-D 09 to 60 R
Technical features
Set reference
EUHC-D-R
Sizes
EUKC 09 DT EUKC 12 DT EUKC 18 DT EUKC 24 DT EUKC 30 DT EUKC 36 DT EUKC 42 DT EUKC 48 DT EUKC 60 DT
Outdoor unit
Sizes
ENJC 09 DT ENJC 12 DT ENJC 18 DT ENJC 24 DT ENJC 30 DT ENJC 36 DT ENJC 42 DT ENJC 48 DT ENJC 60 DT
Cooling capacity
kW
2.7 (1.2-3.0)
3.4 (1.6-3.6)
5.3 (1.6-5.8)
6.8 (2.0-7.7)
8.0 (2.7-8.3)
Heating capacity
kW
2.9 (1.0-3.0)
3.7 (1.6-4.0)
6.2 (1.4-6.5)
7.3 (2.4-8.0)
8.4 (2.0-9.3) 11.5 (3.8-12.8) 12.4 (3.8-14.5) 16.0 (5.3-18.3) 18.0 (5.0-18.8)
Compressor
Type
Indoor unit
Rotary
Refrigerant
R410A
Power supply
Power input
10.1 (3.5-11.5) 10.6 (3.5-13.0) 13.8 (4.9-14.1) 15.8 (4.0-17.5)
V/Ph/Hz
230 / 1 / 50
230 / 1 / 50 or 400 / 3 / 50
400 / 3 / 50
cooling
kW
0.85
1.07
1.65
2.19
2.56
3.20
3.42
4.36
5.30
heating
kW
0.75
0.97
1.70
2.08
2.44
3.06
3.43
4.50
5.00
EER
3.21
3.21
3.21
3.21
3.21
3.21
3.21
3.21
3.21
COP
3.61
3.61
3.61
3.61
3.61
3.62
3.61
3.67
3.61
cooling
A
A
A
A
A
A
A
A
A
heating
A
A
A
A
A
A
A
A
A
800/700/600
840/740/640
Energy Class
Indoor airflow (H/M/L)
m3/h
External static pressure
Pa
Sound pressure
at 1 m
60
60
60
80
80
150
150
150
150
40 / 38 / 36
37 / 35 / 33
45 / 42 / 39
47 / 44 / 42
47 / 44 / 42
53 / 50 / 46
53 / 50 / 46
53 / 50 / 46
54 / 51 / 48
Indoor (H/M/L)
dB(A)
Outdoor
dB(A)
53
54
57
59
59
61
61
61
63
H (mm)
250
266
266
268
268
290
290
330
385
W (mm)
880
980
980
1 270
1 270
1 226
1 226
1 226
1 463
D (mm)
665
721
721
530
530
775
775
815
799
H (mm)
540
540
700
790
790
1 100
1 100
1 365
1 365
Indoor
Dimensions
W (mm)
776
776
955
980
980
1 107
1 107
1 085
1 085
D (mm)
320
320
396
427
427
440
440
427
427
Indoor unit
kg
26
34
34
37
36
57
57
64
87
Outdoor unit
kg
28
30
48
65
68
86
90
122
127
Gas
3/8”
3/8”
1/2”
5/8”
5/8”
5/8”
5/8”
5/8”
3/4”
Liquid
1/4”
1/4”
1/4”
3/8”
3/8”
3/8”
3/8”
3/8”
3/8”
g
1 200
1 350
1 400
2 400
2 600
3 500
3 800
4 300
5 500
Length
m
20
20
20
30
30
30
50
50
50
Height
m
15
15
15
15
15
15
30
30
30
42
48
60
Outdoor
Net weight
1000/800/600 1600/1400/1200 1500/1300/1100 2300/2110/1850 2300/2110/1850 2500/2300/2100 3150/2900/2600
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +50°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Sizes 36 to 48: Values for single phase models
Accessories
Sizes
Condensate pump
09
12
18
Optional
24
30
-
Weekly timer
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
36
Optional
-
york air-conditioning products
38/39
Minisplit
On/Off Systems
high wall units
multisplits
cassette, floor/ceiling & blower units
window units
york air-conditioning products
High Wall On/Off
YVHFZH 09 to 24
A complete range from 2.7 kW to 6.3 kW
NEW
Features
Remote controller
• Low noise levels
• Class A
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Room temperature sensor
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
Minisplit Systems
40/41
High Wall On/Off
YVHFZH 09 to 24
Technical features
Set reference
YVHFZH
Indoor unit
Sizes
YVHFXH 09
YVHFXH 12
YVHFXH 18
YVHFXH 24
Outdoor unit
Sizes
YVHFYH 09
YVHFYH 12
YVHFYH 18
YVHFYH 24
Cooling capacity
kW
2.7
3.4
5.1
6.3
Heating capacity
kW
2.8
3.5
5.5
6.5
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.80
1.05
1.63
2.00
heating
kW
0.85
1.06
1.71
1.90
EER
3.30
3.23
3.21
3.21
COP
3.41
3.41
3.21
3.41
cooling
A
A
A
A
heating
B
B
C
B
m3/h
480
520
800
1 000
Indoor (L/M/H)
dB(A)
32 / 35 / 37
33 / 36 / 39
37 / 41 / 45
47 / 52 / 57
Outdoor
dB(A)
50
52
55
56
H (mm)
267
283
300
330
W (mm)
815
872
960
1 090
D (mm)
165
178
195
208
H (mm)
540
540
700
847
W (mm)
848
848
1 018
950
D (mm)
320
320
412
412
Indoor unit
kg
10
11
13
16
Outdoor unit
kg
32
40
55
72
Gas
3/8”
1/2”
5/8”
5/8”
Liquid
1/4”
1/4”
3/8”
3/8”
Power input
Energy Class
Indoor airflow (high speed)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
1 250
1 250
1 800
2 000
Length
m
20
20
20
30
Height
m
10
10
15
16
18
24
Operating limit - cooling mode
min./max.
+18°C / +43°C
Operating limit - heating mode
min./max.
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 4 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Available KAHC models with Low Ambient Kit (LAK)
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall On/Off
EAHC 09 to 24 FS-R
A complete range from 2.5 kW to 6.2 kW
Features
Remote controller
• Low noise levels
• Class A
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
Minisplit Systems
42/43
High Wall On/Off
EAHC 09 to 24 FS-R
Technical features
Set reference
EAHC FS-R
Indoor unit
Sizes
EAKC 09 FS-R
EAKC 12 FS-R
EAKC 18 FS-R
EAKC 24 FS-R
Outdoor unit
Sizes
EAJC 09 FS-R
EAJC 12 FS-R
EAJC 18 FS-R
EAJC 24 FS-R
Cooling capacity
kW
2.5
3.1
4.6
6.2
Heating capacity
kW
2.7
3.4
5.0
6.5
Compressor
Type
Rotary
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
cooling
kW
0.80
1.00
1.50
1.90
heating
kW
0.82
0.99
1.35
1.90
EER
3.21
3.21
3.21
3.22
COP
3.41
3.41
3.63
3.41
cooling
A
A
A
A
heating
B
B
A
B
m3/h
350
400
750
780
Indoor (L/M/H)
dB(A)
32 / 35 / 37
32 / 35 / 38
37 / 41 / 45
38 / 41 / 45
Outdoor
dB(A)
50
52
55
56
H (mm)
255
265
298
298
W (mm)
730
790
940
940
D (mm)
174
170
200
200
H (mm)
540
540
540
680
W (mm)
776
798
848
913
D (mm)
320
355
360
428
Power input
Energy Class
Indoor airflow (high speed)
Sound pressure
at 1 m
Indoor
Dimensions
Outdoor
Net weight
Indoor unit
kg
8
9
13
13
Outdoor unit
kg
31
35
40
46
Gas
3/8”
1/2”
1/2”
1/2”
Liquid
1/4”
1/4”
1/4”
1/4”
1 450
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
g
660
840
1 150
Length
m
15
20
25
25
Height
m
10
10
10
10
18
24
Operating limit - cooling mode
min./max.
+18°C / +46°C
Operating limit - heating mode
min./max.
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
Electrostatic dedusting filter
Optional
Silver ion filter
Optional
Active carbon filter
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
High Wall Multi Split
YEHNZH 18 to 24 (2x1)
A complete range from 5.6 kW to 7.0 kW
Features
Remote controller
• Low noise levels
• Active carbon filter
• 2 circuits / 2 compressors running
in same mode
• Automatic restart
• ON/OFF timer
• Automatic air sweep
• Service valve protection cover
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer setting function
• Air flow direction setting
• LCD display
• Turbo mode
• Lock button function
Minisplit Systems
44/45
High Wall Multi Split
YEHNZH 18 to 24 (2x1)
Technical features
INDOOR UNIT (9000 Btu/h)
2 x YEHNXH 09
INDOOR UNIT (12000 Btu/h)
OUTDOOR UNIT
1 x YEHNXH 09
1 x YEHNXH 12
2 x YEHNXH 12
YEHNYH 18
YEHNYH 21
YEHNYH 24
Cooling capacity
kW
5.6 (2.8 x 2)
6.3 (2.8 + 3.5)
7.0 (3.5 x 2)
Heating capacity
kW
6.0 (3.0 x 2)
6.8 (3.0 + 3.8)
7.2 (3.6 x 2)
Compressor
Type (Nb)
Rotary / 2
Power supply
V/Ph/Hz
230 / 1 / 50 + E
Power input (Cooling)
kW
1.86
2.09
Power input (Heating)
kW
1.76
1.99
2.11
3.01 / 3.41
3.01 / 3.41
3.01 / 3.41
Refrigerant
R410A
EER / COP
Energy Class (cooling/heating)
Sound pressure at 1 m (ind./out.)
Indoor unit
B/B
B/B
B/B
30 + 30 / 54
30 + 29 / 55
29 + 29 / 58
H (mm)
265
265 + 275
275
W (mm)
790
790 + 845
845
D (mm)
170
170 + 180
180
H (mm)
700
700
700
W (mm)
1 018
950
950
D (mm)
412
420
420
kg
9 + 9 / 58
9 + 10 / 65
10 + 10 / 65
Gas
2 x 3/8”
3/8” + 1/2”
2 x 1/2”
Liquid
2 x 1/4”
2 x 1/4”
2 x 1/4”
Length
m
2 x 20
2 x 20
2 x 20
Height
m
2 x 10
2 x 10
2 x 10
Dimensions
Outdoor unit
Net Weight (Indoor / Outdoor)
Piping diameter
Pipe run
dB(A)
2.32
Operating limits - cooling mode
min/max
+10°C / +48°C
Operating limits - heating mode
min/max
-7°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Floor/Ceiling
EOHC 09 to 48 FS
A complete range from 2.5 kW to 13.2 kW
Features
Remote controller
• Convertible - floor or ceiling
• Horizontal and vertical
air sweep function
• Wide angle air distribution
• Slim profile - flush mounting
• Low Ambient Kit optional
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
(optional)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
46/47
Floor/Ceiling
EOHC 09 to 48 FS
Technical features
Set reference
EOHC
Indoor unit
Sizes
EOKC 09 FS
EOKC 12 FS
EOKC 18 FS
EOKC 24 FS
EOKC 36 FS
EOKC 42 FS
EOKC 48 FS
Outdoor unit
Sizes
ENJC 09 FS
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
Cooling capacity
kW
2.5
3.5
5.2
7.2
10.0
12.0
13.2
Heating capacity
kW
2.8
3.9
5.7
8.0
11.0
14.0
14.5
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
Power input
V/Ph/Hz
230 / 1 / 50 + E
400 / 3 / 50 + E + N
cooling
kW
0.89
1.23
1.80
2.50
3.50
4.50
5.00
heating
kW
0.98
1.29
2.00
2.59
3.30
4.70
4.80
EER
2.81
2.85
2.89
2.88
2.86
2.67
2.64
COP
2.85
3.02
2.85
3.09
3.33
2.98
3.02
cooling
C
C
C
C
C
D
D
heating
D
D
D
D
C
D
D
Energy Class
Fuse rating
A
25
25
25
25
16
16
16
Indoor airflow (high speed)
m3/h
550
600
700
1 170
1 800
1 800
2 100
Indoor (H/M/L)
dB(A)
45 / 42 / 39
46 / 42 / 38
54 / 50 / 46
50 / 48 / 46
54 / 51 / 48
54 / 51 / 48
58 / 55 / 52
Outdoor
dB(A)
54
56
56
59
58
60
63
H (mm)
695
695
695
600
695
695
695
1 590
Sound pressure
at 1 m
W (mm)
836
836
836
1 300
1 590
1 590
D (mm)
238
238
238
188
238
238
238
H (mm)
540
540
540
695
840
1 250
1 250
W (mm)
820
820
820
1 018
1 018
1 032
1 032
D (mm)
320
320
320
412
412
412
412
Indoor unit
kg
27
27
27
32
42
42
48
Outdoor unit
kg
30
40
40
59
90
112
112
Gas
1/2”
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
g
1 100
1 000
1 500
2 200
3 200
3 550
3 800
Length
m
20
20
20
30
50
50
50
Height
m
15
15
15
15
30
30
30
36
42
48
Indoor
Dimensions
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
09
12
18
24
Wired control
Optional
Weekly timer
Optional
Central control
Optional
Low Ambient Kit
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Cassette
EKHC 12 to 48 FS
A complete range from 3.5 kW to 14.2 kW
Features
Remote controller
• Condensate pump
• Fresh air intake for sizes 24 to 42
• 3 fan speeds
• 600 x 600 mm (size 12 & 18)
• Auto restart
• Low noise operation
• Low Ambient Kit optional
• Rustproof casing
• Blue fin protection (indoor and
outdoor units)
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Wired control
(optional)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• LCD display
Minisplit Systems
48/49
Cassette
EKHC 12 to 48 FS
Technical features
Set reference
EKHC
Indoor unit
Sizes
EKKC 12 FS
EKKC 18 FS
EKKC 24 FS
EKKC 36 FS
EKKC 42 FS
EKKC 48 FS
Outdoor unit
Sizes
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
Cooling capacity
kW
3.5
5.3
7.0
10.0
12.0
13.2
Heating capacity
kW
3.6
5.7
7.5
11.0
14.0
14.5
Compressor
Type
Rotary
Scroll
Refrigerant
R410A
Power supply
V/Ph/Hz
230 / 1 / 50 + E
400 / 3 / 50 + E
Cooling
kW
1.15
1.85
2.50
3.50
4.60
4.80
Heating
kW
1.10
1.75
2.50
3.40
4.80
5.20
EER
3,04
2,86
2,80
2,86
2,61
2,75
COP
3,27
3,26
3,00
3,24
2,92
2,79
D
Power input
Energy Class
Cooling
B
C
C
C
D
Heating
C
C
D
C
D
E
Indoor airflow
m3/h
550
550
1 180
1 660
1 660
1 660
Sound pressure Indoor (H/M/L)
at 1 m
Outdoor
dB(A)
47 / 45 / 43
47 / 45 / 43
47 / 45 / 43
53 / 51 / 48
53 / 51 / 48
53 / 51 / 48
dB(A)
56
56
59
60
60
63
H (mm)
230
230
240
320
320
320
Indoor
Dimensions
Outdoor
Net weight
W (mm)
600
600
840
840
840
840
D (mm)
600
600
840
840
840
840
H (mm)
540
540
695
840
1 250
1 250
W (mm)
820
820
1 018
1 018
1 032
1 032
D (mm)
320
320
412
412
412
412
50 / 650 / 650
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
60 / 950 / 950
Panel H/W/D
mm
50 / 650 / 650
Indoor unit
kg
20
20
30
38
38
32
Outdoor unit
kg
32
40
59
90
112
112
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
g
1 000
1 500
2 200
3 200
3 550
3 800
Length
m
20
20
30
50
50
50
Height
m
15
15
15
30
30
30
36
42
48
Type of connection
Piping
Diameter
Refrigerant charge
Max pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
Wired control
Optional
Weekly timer
Optional
Central control
Optional
Low Ambient Kit
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Blower
EUHC 12 to 60 FT
A complete range from 3.5 kW to 16.0 kW
Features
Wired control
• Air filter included
• Condensate pump optional
• Fresh air intake
• Indoor unit with centrifugal fan
• Large distances between indoor
and outdoor units
• Indoor units with high pressure
• Quiet operation
• Wired control with weekly timer
• Infrared remote control
• Low Ambient Kit optional
• Blue fin protection (indoor and
outdoor units)
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Weekly timer
• LCD display
Remote controller
• Wireless
• 5 operation modes
(Cool/Heat/Auto/Dry/Fan)
• Sleep mode
• Room temperature setting
• Fan speed selection
• Timer
• Air flow direction setting
• LCD display
Minisplit Systems
50/51
Blower
EUHC 12 to 60 FT
Technical features
EUHC
Set reference
Indoor unit
Sizes
EUKC 12 FT
EUKC 18 FT
EUKC 24 FT
EUKC 36 FT
EUKC 42 FT
EUKC 48 FT
EUKC 60 FT
Outdoor unit
Sizes
ENJC 12 FS
ENJC 18 FS
ENJC 24 FS
ENJC 36 FS
ENJC 42 FS
ENJC 48 FS
ENJC 60 FS
Cooling capacity
kW
3.5
5.2
7.0
10.2
12.2
13.2
16.0
Heating capacity
kW
3.6
5.7
8.0
11.2
14.0
14.5
18.5
Compressor
Type
Power supply
Rotary
Scroll
230 / 1 / 50 + E
V/Ph/Hz
400 / 3 / 50 + E + N
cooling
kW
1.1
1.85
2.60
3.70
4.80
5.10
6.30
heating
kW
1.1
1.75
2.50
3.50
4.90
4.60
6.00
EER
3.18
2.81
2.69
2.76
2.54
2.58
2.54
COP
3.27
3.26
3.20
3.20
2.86
3.15
3.08
cooling
B
C
D
D
E
E
E
heating
C
C
C
C
D
D
D
2 500
Power input
Energy Class
Indoor airflow
m3/h
600
840
1 400
2 000
2 000
2 300
External static pressure
Pa
25
40
80
150
150
150
150
40 / 38 / 36
42 / 40 / 38
44 / 42 / 40
50 / 48 / 46
50 / 48 / 46
53 / 50 / 46
53 / 50 / 48
Sound pressure
at 1 m
Indoor
dB(A)
Outdoor
dB(A)
56
56
59
60
60
63
64
H (mm)
220
266
268
290
290
290
330
W (mm)
913
1 012
1 270
1 226
1 226
1 226
1 226
D (mm)
680
736
530
775
775
775
815
H (mm)
540
540
695
840
1 250
1 250
1 250
Indoor
Dimensions
W (mm)
820
820
1 018
1 018
1 032
1 032
1 032
D (mm)
320
320
412
412
412
412
412
Indoor unit
kg
27
36
37
57
57
57
66
Outdoor unit
kg
32
40
59
90
112
112
123
Gas
1/2”
1/2”
5/8”
3/4”
3/4”
3/4”
3/4”
Liquid
1/4”
1/4”
3/8”
1/2”
1/2”
1/2”
1/2”
g
1 000
1 500
2 200
3 200
3 550
3 800
5 000
Length
m
20
20
30
50
50
50
50
Height
m
15
15
15
30
30
30
30
42
48
60
Outdoor
Net weight
Type of connection
Piping
Diameter
Refrigerant charge
Pipe run
Flare
Operating limits - cooling mode
min/max
-10°C / +43°C
Operating limits - heating mode
min/max
-15°C / +24°C
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5 m with initial charge
Accessories
Sizes
12
18
24
36
Condensate pump
Optional
Low Ambient Kit
Optional
Central control
Optional
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Window
Y8USE 09 to 24
A complete range from 2.6 kW to 5.0 kW
Features
• Super compact design
• Quiet design
• Removable and washable panel
• Infrared control
• Drying operation
• Anti cool wind
• Golden fin condenser
• Memory function
Minisplit Systems
52/53
Window
Y8USE 09 to 24
Technical features
Models
Sizes
Y8USE 09
Y8USE 12
Y8USE 18
Y8USE 24
Cooling capacity
kW
2.8
3.8
5.3
6.2
Heating capacity
kW
2.5
3.5
4.8
5.5
Power supply
V/Ph/Hz
Refrigerant
230 / 1 / 50 + E
Type
R410A
cooling
kW
0.92
1.26
1.76
1.99
heating
kW
0.73
1.02
1.59
1.83
EER
3.04
3.04
3.00
3.01
COP
3.42
3.42
3.00
3.01
Power input
Indoor airflow
m3/h
480
730
850
900
Sound pressure at 1 m
dB(A)
50 / 48 / 46
53 / 51 / 49
57 / 55 / 53
58 / 56 / 53
Dimensions
H
mm
375
428
428
428
W
mm
560
660
660
660
D
770
mm
618
700
770
Net weight
kg
43
57
66
75
Stuffing quantity 40’ HQ
Set
342
225
205
195
Nominal cooling capacity based on : - Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Nominal heating capacity based on : - Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
Information for minisplit installation
Model
Size
High wall
Inverter
YWHJZH
R410A
09
12
18
24
High wall
Inverter
YRHJZH
R410A
09
12
18
24
High wall
Inverter
EVHC-D
R410A
09
12
18
24
High wall
On-Off
YVHFZH
R410A
09
12
18
24
High wall
On-Off
EAHC-FS-R
R410A
09
12
18
24
High wall
Multisplit
EMHC
R410A
18
21
27
30
Multisplit
Inverter
ERJC
R410A
Power
supply
Power
supply
cable size
(mm2)
Interconnection
cables
(number of cables
and sizes)
(mm2)
Indoor
3 x 2.5
4 x 2.5
Maximum
pipe run
(m)
Maximum
height
(m)
YWHJZH
15
20
Outdoor
25
Indoor
15
Piping
diameter
Liquid - gas
Outdoor unit
charged
for a piping
length of
(m)
1/4 - 3/8”
10
Extra
refrigerant
charge for
every meter
(gr)
20
5
1/4 - 5/8”
50
YRHJZH
3 x 2.5
Outdoor
Indoor
3 x 2.5
5
1/4 - 3/8”
4 x 2.5
4 x 2.5
Outdoor
15
5
25
10
EVHC-D
15
20
5
10
25
1/4 - 1/2”
20
1/4 - 3/8”
30
5
1/4 - 1/2”
50
YVHFZH
Indoor
Outdoor
Indoor
Outdoor
3 x 2.5
3x4
3 x 2.5
3x4
5 x 2.5
20
6x4
30
5 x 2.5
EAHC-FS-R
15
20
6x4
10
1/4 - 3/8”
1/4 - 1/2”
15
16
3/8” - 5/8”
4
50
1/4 - 3/8”
10
25
1/4 - 1/2”
30
30
5
50
EMHC
Outdoor
3x4
6 x 2.5
15 *
7
1/4 -3/8”
5*
30
10 *
1/4-3/8” **
5*
40
5
20
ERJC
22
24
28
Outdoor
3x4
4 x 1.5
15 *
ECHC-D
Console Inverter
ECHC-D
R410A
09
12
18
Floor/Ceiling
Inverter
EOHC-D-R
Cassette Inverter
EKHC-D-R
Blower Inverter
EUHC-D-R
R410A
12
18
24
30
36
42
48
Indoor
4 x 2.5
4 x 0.25
15
10
25
1/4 - 3/8”
1/4 - 1/2”
EOHC-D-R / EKHC-D-R / EUHC-D-R
Ind: 3 x 1.5
Out: 3 x 2.5
Outdoor &
Indoor
60
Ind: 3 x 2.5
Out: 3 x 4
20
15
1/4 - 3/8”
1/4 - 1/2”
30
30
60
4 x 0.25
Ind: 3 x 2.5
Out: 3 x 6
Ind: 3 x 2.5
Out: 5 x 4
3/8 - 5/8”
50
5
30
120
3/8 - 1/4”
EOHC / EKHC / EUHC
Floor/Ceiling
EOHC
Cassette
EKHC
Blower
EUHC
R410A
09
12
18
24
36
Ind: 3 x 1.5
Out: 3 x 2.5
Outdoor &
Indoor
42
48
60
* Each indoor unit
** next indoor unit
Confirm about data in the technical documentation.
Ind: 3 x 1.5
Out: 3 x 4
Ind: 3 x 1.5
Out: 3 x 6
Ind: 3 x 1.5
Out: 5 x 2.5
20
2 x 0.25
15
30
50
1/4 - 1/2”
3/8 - 5/8”
30
1/2 - 3/4”
30
5
60
120
Minisplit Systems
54/55
Load calculation
Customer
Date
Telephone
Type of installation
Project
Adress
Termical loads
PARAMETERS
FACTOR
CAPACITY
not exposed to sunlight
m
2
x
50
=
exposed to sunlight
m
2
x
180
=
exposed to sunlight with curtains
m2
x
135
=
exposed to sunlight with awnings
m2
x
90
=
exposed to sunlight and insulated
m2
x
9
=
exposed to sunlight non insulated
m
2
x
23
=
not exposed to sunlight and insulated
m
2
x
7
=
not exposed to sunlight non insulated
m
2
x
12
=
m2
x
10
=
insulated
m2
x
5
=
not insulated
m
2
x
12
=
insulation under the roof
m
2
x
10
=
not insulation under roof
m
2
x
24
=
insulated
m2
x
7
=
not insulated
m
x
10
=
FRESH AIR
m3/h
x
4,5
=
PERSONS INSIDE THE ROOM
pers.
x
144
=
W
x
1
=
WINDOWS
OUTDOOR
WALLS
INDOOR WALLS *
CEILING
OR ROOF *
FLOOR *
2
WORKING ELECTRICAL EQUIPMENT
NEEDED COOLING CAPACITY
W
* To not consider if they are next to climatisated area.
Important: This is a simplified method to obtain an approximate value of cooling capacity,
as long as the climatic conditions are not extreme.
Only for cooling calculation.
york air-conditioning products
56/57
VRF Systems
yds-c • r410a
indoor unit types
york air-conditioning products
YDS Variable refrigerant flow system
YDMH 100, 140, 252, 280, 335, 400, 450 C
Cooling capacities 10.0 kW to 180.0 kW
YDS System
Comfort – Quality
• Capacities from 10 to 180 kW
• Operating range of nominal power
(10% - 100 %)
• Digital Scroll Technology
• Low noise levels
• High performance
• Flexible and quickly installation
• Cooling and heating
• Connection up to 64 indoor units
per refrigeration circuit
(4 outdoor units)
• Complete range in R410A
• Reduced space of ground
• Is appropriate particularly for
existing buildings
• Cooling to -10°C to +48°C
(outdoor temperature)
• Heating to -15°C to +30°C
(outdoor temperature)
VRF Systems
58/59
YDS Variable refrigerant flow system
YDMH 100, 140, 252, 280, 335, 400, 450 C
Technology of future:
Digital Scroll Compressor operation
The Digital Scroll Compressor uses a simple and
effective method to modulate the capacity of
an AC, giving unparalleled performance in the
modulation field. To modulate the capacity the
Digital Scroll operates in two stages, the “loaded
state” in which the compressor works as a normal
Scroll compressor at full capacity and mass flow,
and the “unloaded state”, where there is not
capacity and mass flow. During the “unloaded
state” there is a separation between the scrolls.
Once the scrolls separate, any gas passing through
is no longer compressed. Changing the cycle
time (“Loaded state” time and “Unloaded state”
time) determines the capacity modulation of the
compressor.
With the introduction of the third generation of the
YDS systems, we offer one of the biggest capacity
capabilities in the VRF market. Cooling capacity from
10 kW to 180 kW is now available. This capacity is
now possible to achieve through connecting from 4
outdoor units together.
The range is based on 2 outdoor units of 10 kW
and 14 kW capacity (Digital scroll compressor) and 4
basic modules of different capacities from 25.2 kW to
45 kW, each basic module including a Digital Scroll
compressor and a conventional compressor.
You can connect up to 64 indoor units in one
10.0 - 14.0 kW
Modulation
chamber
Spring
Bleed hole
Solenoid
valve
Lift piston
assembly
refrigerant circuit. More than 30 models are available,
high walls, cassettes, duct and floor/ceiling types.
The individual setting is done by infra red or wired
remote control. Additionally it is possible to use a
central controller.
140.0 - 180.0 kW
25.2 - 45.0 kW
96.0 - 135.0 kW
53.2 - 90.0 kW
Manufacturer reserves the rights to change specifications without prior notice.
york air-conditioning products
YDS Variable refrigerant flow system
YDMH 100 to 900
YDS Technical features - Single module outdoor unit
Model
YDMH 100C
YDMH 140C
YDMH 252C
YDMH 280C
YDMH 335C
YDMH 400C
YDMH 450C
Cooling capacity
kW
10.00
14.00
25.20
28.00
33.50
40.00
45.00
Heating capacity
kW
12.00
16.00
27.00
31.50
35.00
43.00
47.00
Air flow
m3/h
6 000
6 000
10 000
10 000
10 000
14 000
14 000
Noise level at 1 m
dB(A)
55
55
58
58
58
60
60
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
3.50
4.50
7.31
8.05
9.68
11.53
12.86
Running current “cooling”
A
8.50
8.50
12.5
14.60
17.30
20.20
23.00
Power input “heating”
kW
3.41
4.40
7.01
8.14
9.12
11.17
12.08
Running current “heating”
A
7.60
7.60
12.00
14.50
16.40
19.50
21.40
Compressor
Type
Digital Scroll
Digital Scroll and Fix Scroll
Dimensions and Weight
Height x Width x Length
mm
1245 x 940 x 340
1245 x 940 x 340
1630 x 980 x 800
1630 x 1380 x 830
Weight
kg
117
117
245
382
Piping connections
Gas
18mm / 3/4”
28mm / 1 1/8”
35mm / 1 3/8”
Liquid
10mm / 3/8”
12mm / 1/2”
16mm / 5/8”
Refrigerant charge
Type
kg
R410A
4.10
4.10
11.0
11.00
11.00
16.00
16.00
Piping length / Height difference
Max. piping length
m
70
70
175
175
175
175
175
Max. height difference
m
8
8
70
70
70
70
70
6
8
13
16
20
20
20
Max. number of indoor units
YDS Technical features - Outdoor units with two module combinations
Model
YDMH 532C
YDMH 560C
YDMH 615C
YDMH 680C
YDMH 730C
YDMH 785C
YDMH 850C
YDMH 900C
Module combinations
1x YDMH252
1x YDMH280
2x YDMH280
1x YDMH280 1x YDMH280 1x YDMH280 1x YDMH335 1x YDMH400 2x YDMH450
1x YDMH335 1x YDMH400 1x YDMH450 1x YDMH450 1x YDMH450
Cooling capacity
kW
53.2
56.00
61.50
68.00
73.00
78.50
85.00
90.00
Heating capacity
kW
58.5
63.00
66.50
74.50
78.50
82.00
90.00
94.00
Noise level at 1 m
dB(A)
62
62
62
62
62
63
63
63
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
15.36
16.10
17.73
19.58
20.91
22.54
24.39
25.72
Power input “heating”
kW
15.15
16.28
17.26
19.31
20.22
21.20
23.25
24.16
Dimensions and Weight
Height x Width x Length
mm
1630 x 1960 x 800
1630 x 2360 x 830
1630 x 2760 x 830
Weight
kg
490
627
764
Piping size between the outdoor unit and the first branch
Gas
35mm / 1 3/8”
42mm / 1 5/8”
Liquid
18mm / 3/4”
22mm / 7/8”
Refrigerant piping
Piping 1
16mm / 5/8”
Piping 2
18mm / 3/4”
Connection between modules (out. groups)
Max. number of indoor units
YDSA / RD102
20
20
20
YDSA / RD103
20
20
20
32
32
60/61
VRF Systems
YDS Variable refrigerant flow system
YDMH 960 to 1800
YDS Technical features - Outdoor units with three module combinations
Model
YDMH 960C
YDMH 1010C YDMH 1065C YDMH 1130C YDMH 1180C YDMH 1235C YDMH 1300C YDMH 1350C
Module combinations
YDMH280 1x YDMH280 1x YDMH280 1x YDMH335 1x YDMH400
2x YDMH280 2x YDMH280 1x
1x YDMH335 1x YDMH400 2x
1x YDMH400 1x YDMH450 1x
YDMH450 2x YDMH450 2x YDMH450 3x YDMH450
YDMH450 1x YDMH450
Cooling capacity
kW
96.00
101.00
106.50
113.00
118.00
122.50
130.00
135.00
Heating capacity
kW
106.00
110.00
113.50
121.50
125.50
129.00
137.00
141.00
Noise level at 1 m
dB(A)
64
64
64
64
64
64
64
64
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
27.63
28.96
30.59
32.44
33.77
35.40
37.25
38.58
Power input “heating”
kW
27.45
28.36
29.34
31.39
32.30
33.28
35.33
36.24
Dimensions and Weight
Height x Width x Length
mm
1630 x 3340 x 830
1630 x 3740 x 830
1630 x 4140 x 830
Weight
kg
872
1.009
1.146
Piping size between the outdoor unit and the first branch
Gas
42mm / 1 5/8”
Liquid
22mm / 7/8”
Refrigerant piping
Piping 1
16mm / 5/8”
Piping 2
18mm / 3/4”
Connection between modules (out. groups)
1x YDSA / RD102 + 1x YDSA / RD01
Max. number of indoor units
32
32
32
1x YDSA / RD103 + 1x YDSA / RD01
40
40
40
40
40
YDMH 1750C
YDMH 1800C
YDS Technical features - Outdoor units with four module combinations
Model
YDMH 1405C
YDMH 1455C
Module combinations
YDMH335 2x YDMH335
3x YDMH335 3x YDMH335 2x YDMH400
1x YDMH400 1x YDMH450 1x
1x YDMH450 2x YDMH450
YDMH 1520C
YDMH 1570C
YDMH 1630C
1x YDMH280
3x YDMH450
YDMH 1685C
1x YDMH335 1x YDMH400
3x YDMH450 3x YDMH450 4x YDMH450
Cooling capacity
kW
140.50
145.50
152.00
156.00
163.00
168.50
175.00
180.00
Heating capacity
kW
148.00
152.00
160.00
164.00
172.50
176.00
184.00
188.00
Noise level at 1 m
dB(A)
65
65
65
65
65
65
65
65
Electrical features
Power supply
3/N/ 400V 50Hz
Power input “cooling”
kW
40.57
41.90
43.75
45.08
46.63
48.26
50.11
51.44
Power input “heating”
kW
38.53
39.44
41.49
42.40
44.38
45.36
47.41
48.32
Dimensions and Weight
Height x Width x Length
mm
1.630 x 4.320 x 830
1.630 x 4.720 x 830
1.630 x 5.120 x 830
1.630 x 5.520 x 830
Weight
kg
1.117
1.254
1.391
1.528
Piping size between the outdoor unit and the first branch
Gas
54mm / 2 1/8”
Liquid
28mm / 1 1/8”
Refrigerant piping
Piping 1
16mm / 5/8”
Piping 2
18mm / 3/4”
Connection between modules (out. groups)
Max. number of indoor units
1x YDSA / RD102 + 2x YDSA / RD01
50
50
50
1x YDSA / RD103 + 2x YDSA / RD01
50
50
64
64
64
york air-conditioning products
YDS Technical features indoor units
High wall (EXV integrated)
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Starting current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YDHWC022C
YDHWC028C
YDHWC036C
YDHWC045C
YDHWC056C
2.2
2.6
2.8
3.2
580 / 500 / 420
35 / 32 / 29
3.6
4.0
4.5
5.0
5.6
6.3
900 / 760 / 650
40 / 38 / 34
230 / 1 / 50 + N + E
2.5
290 x 915 x 210
12
3.3
315 x 1070 x 210
15
12mm / 1/2”
6mm / 1/4”
Cassette
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / L
Power supply
Electrical
features
Starting current
HxWxD
Dimensions
and Weight
Weight
HxWxD
Panel
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
mm
kg
YDCS022C
YDCS028C
YDCS036C
YDCS045C
YDCS056C
2.2
2.6
2.8
3.2
3.6
4.0
570 / 400
4.5
5.0
5.6
6.3
38 / 35
18
39 / 36
230 / 1 / 50 + N + E
3.6
254 x 580 x 580
18
30 x 650 x 650
3
18
24
24
12mm / 1/2”
6mm / 1/4”
16mm / 5/8”
10mm / 3/8”
Cassette
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Starting current
HxWxD
Dimensions
and Weight
Weight
HxWxD
Panel
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
mm
kg
YDCL056C
YDCL071C
YDCL080C
YDCL090C
YDCL112C
YDCL140C
5.6
6.3
950 / 800 / 650
42 / 38 / 35
7.1
8.0
8.0
9.0
9.0
10.0
11.2
12.5
14.0
15.0
1 802 / 1 483 / 1 284
48 / 45 / 43
1 220 / 1 010 / 820
48 / 45 / 42
1 540 / 1 300 / 1 120
53 / 48 / 45
230 / 1 / 50 + N + E
3.6
4.2
6.0
300 x 840 x 840
36
230 x 840 x 840
27
30
46 x 950 x 950
6
16mm / 5/8”
10mm / 3/8”
VRF Systems
62/63
Convertible console floor/ceiling
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Starting current
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
kW
kW
m3/h
dB(A)
V/Ph/Hz
A
mm
kg
YDFC036C
YDFC045C
3.5
4.0
650 / 570 / 500
4.7
5.1
YDFC056C
YDFC071C
5.3
6.2
800 / 600 / 500
43 / 41 / 38
4.7
YDFC080C
YDFC090C
YDFC112C
7.0
8.2
7.9
8.8
9.4
10.6
1 400 / 1 200 / 1 000
45 / 43 / 40
230 / 1 / 50 + N + E
6.2
660 x 1 285 x 198
37
16mm / 5/8”
10mm / 3/8”
5.4
660 x 995 x 198
29
12mm / 1/2”
6mm / 1/4”
YDFC140C
11.7
14.1
13.2
15.5
2 000 / 1 800 / 1 600
47 / 45 / 42
7.7
680 x 1 670 x 240
54
Floor standing
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Electrical features Power supply
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
YDEFS022C
kW
kW
m3/h
dB(A)
V/Ph/Hz
mm
kg
YDEFS028C
YDEFS036C
2.2
2.8
2.6
3.2
530 / 456 / 400
569 / 485 / 421
37 / 35 / 33
3.6
4.0
624 / 522 / 375
39 / 37 / 35
YDEFS045C
4.5
5.0
660 / 542 / 440
39 / 37 / 35
230 / 1 / 50 + N + E
625 / 1 200 / 220
37
625 / 1 000 / 220
30
YDEFS56C
5.6
6.3
1 150 / 970 / 830
41 / 39 / 37
YDEFS071C
YDEFS080C
7.1
8.0
8.0
9.0
1 380 / 1 100 / 870 1 332 / 1 212 / 1 023
43 / 41 / 38
625 / 1 500 / 220
44
16mm / 5/8”
10mm / 3/8”
12mm / 1/2”
6mm / 1/4”
Floor standing concealed
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Electrical features Power supply
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
YDCFS022C
kW
kW
m3/h
dB(A)
V/Ph/Hz
mm
kg
YDCFS028C
YDCFS036C
2.2
2.8
2.6
3.2
530 / 456 / 400
569 / 485 / 421
37 / 35 / 33
3.6
4.0
624 / 522 / 375
39 / 37 / 35
YDCFS045C
4.5
5.0
660 / 542 / 440
39 / 37 / 35
230 / 1 / 50 + N + E
544 / 1 036 / 212
29.5
544 / 840 / 212
26
YDCFS56C
YDCFS071C
YDCFS080C
5.6
6.3
1 150 / 970 / 830
7.1
8.0
1 380 / 1 100 / 870
41 / 39 / 37
8.0
9.0
1 332 / 1 212 / 1 023
544 / 1 336 / 212
12mm / 1/2”
6mm / 1/4”
545 / 1 336 / 212
36
16mm / 5/8”
10mm / 3/8”
Blower
Model
Cooling
Capacity
Heating
Air flow
Noise level at 1 m H / M / L
Power supply
Electrical
features
Static pressure
HxWxD
Dimensions
and Weight
Weight
Gas
Piping
Liquid
YDDN022C
kW
kW
m3/h
dB(A)
V/Ph/Hz
Pa
mm
kg
YDDN028C
2.2
2.6
YDDN036C
2.8
3.6
3.2
4.0
570 / 400 / 320
34 / 32 / 30
35 / 33 / 31
10
210 x 955 x 385
15
12mm / 1/2”
6mm / 1/4”
YDDN045C YDDN056C
YDDN071C
YDDN080C YDDN090C
4.5
5.6
7.1
8.0
5.0
6.3
8.0
8.4
1 160 / 1 100 / 950
1 400 / 1 100 / 900
45 / 41 / 38
46 / 44 / 42
230 / 1 / 50 + N + E
40
298 x 1 000 x 800
37.2
16mm / 5/8”
10mm / 3/8”
9.0
10.0
YDDN112C
YDDN140C
11.2
14.0
12.5
15.0
1 800 / 1 500 / 1 200
47 / 45 / 43
48 / 46 / 44
70
298 x 1 350 x 800
51.4
york air-conditioning products
Remote Controllers
R05 Remote Controller
Light background, LCD display screen, clock function, ON / OFF / Temperature setting / Mode
setting / Fan speed setting / Horizontal swing setting functions. Using for the Floor/Ceiling units.
R51 Remote Controller
LCD display, clock function, ON / OFF / Temperature setting / Mode setting / Fan speed /
Swing etc. Using for all the indoor units except Floor/Ceiling units.
Wired Controller & Weekly Timer
AMR01Y Wired Controller
ON / OFF / Mode setting / Temp. setting / Fan speed / Time setting / Swing, etc.
Temp sensor built-in.
AMR02M Weekly schedule timer
Control one indoor unit.
Note: Weekly schedule timer and indoor CCM cannot be used simultaneity
Central Control Monitor
AMR02Y Outdoor CCM
Max. 32 outdoor units control.
AMR03Y Indoor CCM
Max. 64 indoor units control; New mode lock function.
AMR09Y Indoor CCM
Max. 64 indoor units control. New weekly timer function.
For BMS connection ckeck with your JCI representative.
64/65
Refrigerant collector
Communication
system connection
VRF Systems
YDS System - System Diagram
Indoor unit
power supply
Outdoor unit
power supply
Communication
control connection
Central control
Infrared
remote control
Infrared
remote control
Infrared
remote control
YORK System YDS
The YORK system with Digital Scroll
is working like the VRF principleand
offers you economical airconditioning system for projects,
which are requiring more capacity
than the normal split and multi split
solutions.
A
The lengths for the connecting tubes
between the indoor and outdoor
have been prolonged, which brings
you more flexible solutions for
complex air-conditioning projects.
B
C
A – Real length of refrigerant piping : 150 m.
B – Maximum difference in height : 70 m.
C – Maximum difference in height between 2 indoor units : 15 m.
Wired control
Infrared
remote control
CD Rom 2012 :
Commercial Leaflets, Technical Library,
Software Tools and more...
CD available at
Johnson Controls
office
york air-conditioning products
m-cd-g2012
Residential & Light Commercial 2012
Minimum system requirements
• Operating system Windows 98 or better
• Pentium II processor or superior
• 32 MB of RAM
• Screen resolution 800 x 600 pixels, 16 bits
To view all pdf files, the Adobe Acrobat Reader© program is required. If said
program is not installed, install the one included in this CD-ROM.
Multi-language Technical Information
easy-direct-clear
PUBL-6910
© 2012 Johnson Controls, Inc.
www.johnsoncontrols.com
E-CAT-MIN-G2012
http://www.johnsoncontrols.co.uk