Koganei IBZR8-4E1, IBZR8Z-E, IBZR8Z-PJ3/8J, IBZR8Z-PJJ Manual
Koganei IBZR8Z-PJ3/8J is an intermediate piping block for use with iB-ZERO series 5-port solenoid valves. It features a quick fitting exhaust port for convenient tube connections, making assembly a breeze. It's designed to be lightweight and compact, with a nearly 40% smaller footprint than previous models. The IBZR8Z-PJ3/8J is ideal for applications requiring efficient air distribution and compact manifold design.
PDF
Download
Document
Advertisement
Advertisement
Catalog No.BK-V0018 http://www.koganei.co.jp 5-port manifold solenoid valve PAT.PEND. The first in the world! Integrally molded, all-plastic body! NEW OPTION!! Quick fitting exhaust port type Possible to exhaust with tube piping, from the 3(R) port of the piping block. End block with quick fitting exhaust port 1(P), 3(R) piping size ・φ10mm tube ・3/8 inch tube 15 0.5 mm 91 [ Intermediate piping block with quick fitting exhaust port in ] 35.3 mm [ 1.390 in] Intermediate piping block with quick fitting exhaust port ・φ10mm tube ・3/8 inch tube Piping block with quick fitting exhaust port Thin and lightweight! Nearly 40% smaller ⇦ Nearly Exhaust port (Integrated muffler) 1(P), 3(R) piping size 57% less mass than the previous 180 series manifold iB-ZERO Easy assembly Simple Selection Previous 180 series * Valve width: 18 mm [0.709 in.] Its simple configuration makes assembling the manifold a breeze. Instant assembly → quick delivery All are integrated fitting types (select from mm:φ4, φ6,φ8 / in: 5/32 , 1/4 , 5/16) Perfect for cylinder controls from small diameter to about φ80 [3.150 in] Safety precautions(iB-ZERO) Always read these precautions carefully before use. Before selecting and using the products, please read all safety precautions carefully to ensure proper product use. The safety precautions described below are to help you use the product safely and correctly, and to prevent injury or damage to you, other people, and assets. Always adhere to the following safety regulations: ISO4414 (Pneumatic fluid power - General rules and safety requirements for systems and their components) and JIS B 8370 (General rules relating to pneumatic systems). Items are ranked as follows according to degree of potential danger or damage: “DANGER”, “WARNING”, “CAUTION”, and “ATTENTION”. DANGER Indicates situations that can be clearly predicted as dangerous. Failure to avoid the situation creates the risk of death or serious injury. It could also result in damage or destruction of assets. WARNING Indicates situations that, while not immediately dangerous, could become dangerous. Failure to avoid the situation creates the risk of death or serious injury. It could also result in damage or destruction of assets. CAUTION Indicates situations that, while not immediately dangerous, could become dangerous. Failure to avoid the situation creates the risk of minor or semi-serious injury. It could also result in damage or destruction of assets. ATTENTION While there is little chance of injury, this content refers to points that should be observed for appropriate use of the product. ■ This product was designed and manufactured for use in general industrial machinery. ■ When selecting and handling equipment, the system designer or another person with sufficient knowledge and experience should always read the safety precautions, catalog, instruction manual and other literature before commencing operation. Improper handling is dangerous. ■ After reading the catalog, instruction manual, etc., always keep them in a location where they are readily available for reference to users of this product. ■ If transferring or lending the product to another person, always attach the catalog, instruction manual, etc., to the product where they are easily visible, to ensure that the new user can use the product safely and properly. ■ The danger, warning and caution items listed under these safety precautions do not cover all possible contingencies. Read the catalog and instruction manual carefully, and always keep safety first. ●B efore supplying air or electricity to the device and before starting DANGER operation, always conduct a safety check of the area of machine operation.Unintentional supply of air or electricity could possibly result in ●D o not use the product for the purposes listed below: electric shock, or in injury caused by contact with moving parts. 1 . Medical equipment related to maintenance or management ● D o not touch terminals, switches, or other parts, while power is turned of human lives or bodies. on.Doing so creates the risk of electric shock and malfunction. 2 . M achines or equipment designed for the purpose of ●D o not allow the product to be thrown into fire. Doing so creates the moving or transporting people. risk of explosion and the release of toxic gases. 3 . Critical safety components in mechanical devices. ● D o not sit on the product, place your foot on it, or place other objects This product has not been planned or designed for purposes on it.Doing so creates the risk of injury due to tripping or the product that require high levels of safety. Using the product in any of the tipping over or dropping, resulting in product damage and abnormal, ways described above creates the risk of loss of human life. erratic, or runaway operation. ●D o not use the product in locations with or near dangerous ● When conducting any kind of operation for the product, such as substances such as flammable or ignitable substances. This product maintenance, piping connection and disconnection, inspection, is not explosion-proof. Doing so creates the risk of ignition and fire. repair, or replacement, always turn off the air supply completely and ●W hen mounting the product and workpiece, always make sure they confirm that residual pressure inside the product or in piping are firmly supported and secured in place. Falling, dropping, or connected to the product is zero before proceeding. In particular, be abnormal operation of the product creates the risk of personal injury. aware that residual air will still be in the air compressor or air storage ●P eople using a pacemaker or other similar medical devices should tank. The actuator could abruptly move if residual air pressure keep a distance of at least one meter away from the product. Getting remains inside the piping, causing injury. too close to the product creates the risk of malfunction of a pacemaker due to the strong magnet built into the product. ●B efore commencing normal operation, confirm that the valve is in the ●N ever attempt to modify the product. Abnormal operation can lead to injury, etc. proper switching position,and only then commence the operation. ●N ever attempt inappropriate disassembly, assembly or repair of the Failure to do so could lead to erroneous operation. product relating to basic construction, or to its performance or to ● B efore performing any kind of wiring work, be sure to turn off power. functions. Doing so creates the risk of injury, electric shock, fire, etc. Failure to do so creates the risk of electric shock. ●D o not splash water on the product. Spraying it with water, washing it, ●C orrectly apply the rated voltage to the solenoid. Applying the wrong or using it under water could result in malfunction of the product voltage will make it impossible to obtain the specified function, and leading to injury, electric shock, fire, etc. creates the risk of damage to and burnout of the product. ●W hile the product is in operation, avoid touching it with your hands or otherwise approaching too close. Also, do not attempt to make any ●D o not allow lead wires and other cords to become damaged. adjustments to internal or attached mechanisms, or to perform any Allowing a cord to become cut, bent excessively, pulled, rolled up, type of adjustment (manual override, connecting or disconnecting placed under heavy objects, or squeezed between two objects cable connectors, adjusting pressure switches, disconnecting tubes creates the risk of current leaks or defective continuity that can lead or sealed plugs, etc.) while the product is in operation. to fire, electric shock, or abnormal operation. U nder such conditions, the actuator may move suddenly, creating ●D o not connect or disconnect connectors while power is turned on. the risk of personal injury. Also, never apply unnecessary force to connectors. Doing so creates the risk of personal injury, device damage, and electric shock due to abnormal machine operation. WARNING ●A lways check the catalog and other reference materials for correct product wiring and piping. Improper wiring and piping creates the risk ●B ecause Koganei products are designed for use under a wide variety of damage to and abnormal operation of the actuator, etc. of conditions, decisions concerning conformance with a particular ● In initial operations after the equipment has been idle for 48 hours or system should be made upon the careful evaluation by the person in more, or has been in storage, there is a possibility that contacting charge of system design.Assurances concerning expected system parts may have become stuck, resulting in equipment operation performance and safety are the responsibility of the designer who delays or in sudden movements. Before these initial operations, decides system conformity. Be sure to use the latest catalogs and always run a test to check that operating performance is normal. technical materials to study and evaluate specification details, to ●W hen the device is not used for long periods (over 30 days), it is consider the possibility of machine breakdown, and to configure a possible that the contacting parts may have become stuck leading system that ensures fail-safe safety and reliability. to slow operation or sudden movements. Check for proper ●D o not use the product in excess of its specification ranges. Doing so operation a minimum of once every 30 days. creates the risk of product breakdown, loss of function, or damage. It could also drastically reduce operating life. 1 Safety precautions(iB-ZERO) ●F or double solenoid type (excluding the Tandem 3-port valve), do not apply current through both solenoids simultaneously. It is impossible in such a situation to maintain the correct valve position,and the equipment may operate in an unintended direction, leading to the possibility of equipment breakdown or personal injury. ● For double solenoid types, due to the valve position when newly purchased, connected equipment may operate in unintentional directions,and may lead to damage of the machine, or personal injury, so prepare countermeasures to avoid danger. ●D o not locate the solenoid valve and the wiring that controls it near power lines running a large current, powerful magnetic fields, or where power surges occur. Doing so could cause erratic operation. ●S olenoid valves generate surge voltage and electromagnetic waves at the OFF operation, which can interfere with the operation of nearby equipment. Use a surge protected solenoid or implement appropriate surge and electromagnetic protection measures for the electrical circuitry. ●D o not use the product at the beach, in direct sunlight, near mercury vapor lamps, or near equipment that generates ozone. Ozone causes rubber components to deteriorate resulting in reduced performance, or a limitation or stop of functions.(Excluding items with measurements against ozone.) ●D o not use any type of medium that is not specifically stipulated in the specifications. Using a non-specified medium could lead to short term loss of function, sudden degradation of performance, and a reduced operating life. ●W hen a solenoid valve is installed within the control panel and when the energizing time is long, implement heat dissipation measures in order to keep the temperature around the solenoid within specifications. Also note that continuous energizing for long periods will result in heat generation by the coil which can lead to deterioration of solenoid valve performance and shortening of its service life, and can adversely affect nearby equipment. Contact Koganei if you need to continuously energize for long periods or if the energizing time in a day needs to be longer than the deenergizing time. ●A fter completing wiring work, check to make sure that all connections are correct before turning on power. ●W hen using the valve in a manifold, be aware when operating an air cylinder, or performing air blowing operations, back pressure could cause erratic operations of the cylinder or erroneous air delivery from the air blow port. Caution is particularly needed when operating single acting cylinders, or when operating a cylinder and blowing air from the same manifold. ●D o not use the product in locations subject to direct sunlight (ultraviolet radiation), high temperatures or high humidity, dust, salt, or iron powder. Do not expose the product to fluids or an ambient atmosphere that contains organic solvents, phosphate-based hydraulic fluid, sulfur dioxide gas, chlorine gas, acids, etc. It could lead to early shutdown of some functions, a sudden degradation of performance, and a reduced operating life. For information about materials, see Materials of major parts. 注意 ●W hen mounting the product, leave room for adequate working space around it. Failure to do so will make it more difficult to conduct daily inspections or maintenance, which could eventually lead to system shutdown or damage to the product. ●W henever transporting or installing a heavy product, use a lift or supports to securely support it, and use several people to help lift it and take other precautions to ensure personal safety. ● Do not bring any magnetic media or memory media, or other similar items within one meter of an energized solenoid valve. Doing so creates the risk of damage to data on the magnetic media due to magnetism. ● If leakage current is flowing in the control circuit, there is a possibility of the product performing an unintended operation. Take measures against current leaking in the control circuit, to ensure that the leakage current value does not exceed the allowed range in the product specifications. ● Do not use a solenoid valve in locations subject to large electrical currents or strong magnetic fields. Doing so could result in erratic operation. ●O il from a compressor (except from the oil free compressor) can greatly reduce product performance and can even cause functional stoppages. Be sure to install a mist filter before pneumatic equipment to remove oil. ●T he properties of the lubrication oil can change when used in dry air where dew point temperatures is lower than –20°C [–4°F]. It could result in degraded performance or in functional shutdown. ● While the product is in operation, avoid touching it with your hands or otherwise approaching too close. Heat generated by the coil can cause burn injury. ATTENTION ●W hen considering the possibility of using this product in situations or environments not specifically noted in the catalog or instruction manual, or in applications where safety is an important requirement such as in aircraft eguipment, combustion equipment, leisure equipment, safety equipment, and other places where human life or assets may be greatly affected, take adequate safety precautions such as allowing plenty of margin for ratings and performance, or failsafe measures. Contact the sales department at Koganei regarding use in such applications. ●W hen handling the product, wear protective gloves, safety glasses, safety shoes, and other protective clothing. ●W hen the product can no longer be used, or is no longer necessary, dispose of it appropriately, according to the “Law Regarding the Disposal and Cleaning of Waste” or other local governmental rules and regulations, as industrial waste. ●P neumatic equipment can exhibit degraded performance and function over its operating life. Always conduct daily inspections of the pneumatic equipment, and confirm that all requisite system functions are satisfied, to prevent accidents from happening. ●A ir leakage of the solenoid valves cannot be cut to zero. Take volume and holding time requirements into consideration when designing pressure (including vacuum) retention in the pressure vessel, and other factors. ●A ir leakage of the solenoid valves cannot be cut to zero. Take volume and holding time requirements into consideration when designing pressure (including vacuum) retention in the pressure vessel, and other factors. Other precautions ● Always observe the following items. 1. When using this product in pneumatic systems, always use genuine Koganei parts or compatible parts (recommended parts). When conducting maintenance and repairs, always use genuine Koganei parts or equivalent parts (recommended parts). Always observe the prescribed methods and procedures. 2. Never attempt inappropriate disassembly or assembly of the product relating to basic configurations, or its performance or functions. Koganei shall not be held responsible for any problems that occur as a result of these items not being properly observed. Warranty and General Disclaimer 1. Warranty Period Koganei warrants this product for a period of no more than 180 days from the date of delivery. 2. Scope of Warranty and General Disclaimer (1) T he Koganei product warranty covers individual products. When a product purchased from Koganei or from an authorized Koganei distributor malfunctions during the warranty period in a way that is attributable to Koganei's responsibility, Koganei will repair or replace the product free of charge. Even if a product is still within the warranty period, its durability is determined by its operation cycles and other factors. Contact your nearest K oganei sales o ffic e or the K oganei o v er sea s department for details. (2) Koganei shall not be held responsible for any losses or for any damage to other machinery caused by breakdown, loss of function, or loss of performance of Koganei products. (3) Koganei shall not be held responsible for any losses due to use or storage of the product in a way that is outside of the product specifications prescribed in Koganei catalogs and the instruction manual, and/or due to actions that violate the mounting, installation, adjustment, maintenance and other safety precautions. (4) Koganei shall not be held responsible for any losses caused by breakdown of the product due to factors outside the responsibility of Koganei, including but not limited to fire, natural disaster, the actions of third parties, and intentional actions or errors by you. 2 Handling Instructions and Precautions Manual override Internal circuit ●24 VDC Solenoid with LED indicator and surge suppression Lead wire (+) Red (Red) Lead wire (-) Black NOTE 1. D o not apply megger between the pins. 2. M alfunctions, such as the solenoid valve not returning to normal, may occur if there is a leakage current within the circuit. Always use it at less than the allowable leakage current shown in the solenoid specifications. If circuit conditions, etc. cause the leakage current to exceed the maximum allowable leakage current, consult us. 3. F or the double solenoid configuration, avoid energizing both solenoids simultaneously. To operate the manual override, press it all the way down. For the single solenoid, the valve works the same as when in the energized state as long as the manual override is pushed down, and returns to the rest position upon release. For the double solenoid, pressing the manual override on the 14 (SA) side switches the 14 (SA) to the energized state, and the unit remains in that state even after the manual override is released. To return it to the rest position, operate the manual override on the 12 (SB) side. This is the same for the solenoid 12 (SB). Attaching and removing plug connector Use fingers to insert the connector into the pin, push it in until the lever claw latches onto the protruded section of the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the protruded section of the connector housing, and pull it out. Protrusion Pin Housing Lever Connector assembly KSB0352Z Connector Contact Crimping of connecting lead wire and contact To crimp lead wires into contacts, strip off 4 mm [0.16 in] of the insulation from the end of the lead wire, insert it into the contact, and crimp it. Be sure at this time to avoid catching the insulation on the exposed wire crimping section. Exposed wire 4 mm [0.16 in] Lead wire Equivalent to AWG#22〜#28 Insulation crimp tab Hook NOTE Exposed wire crimping section Insulation (Maximum outer diameter: φ1.7 [0.067]) 1. Do not pull hard on the lead wire. 2. Always use a dedicated tool for crimping of connecting lead wire and contact. Contact: Crimping tool: Model 702062-2M Manufactured by Sumiko Tech, Inc. Model F1-702062 Manufactured by Sumiko Tech, Inc. Attaching and removing contact and connector Insert the contact with lead wire into a plug connector □ hole until the contact hook latches on and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove it, insert a tool with a fine tip (such as a small screwdriver) KSB0353Z into the rectangular hole on the side of the plug connector to push up on the hook, and then pull out the lead wire. NOTE 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc. 2. If the pin is bent, use a small screwdriver, etc. to gently straighten out the pin, and then complete the connection to the plug connector. 3 SH NOTE 1. T he iB-ZERO series uses pilot type solenoid valves, so if you do not supply air to the 1 (P) port, the main valve will not change, even if you operate the manual override. 2. D o not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could result in damage to the manual override. Identification of quick fitting size Tube size unit mm size in size Indication of polarity(DC) Contact PU Release ring color Ivory Milk white Handling Instructions and Precautions Media General precautions Mounting 1. While any mounting direction is allowed, be sure to avoid strong shocks or vibrations applied directly to the body. 2. Avoid using in the locations and environment listed below, as it could result in malfunction of the valve. If use in such conditions is unavoidable, always provide a cover or other adequate protective measures. ● Location directly exposed to water drops or oil drops ● Environment where a valve body is subject to dew condensation ● Location directly exposed to machining chips, dust, etc 3. In piping connection with valves, flush the tube completely (by blowing compressed air) before piping. Intrusion of machining chips or sealing tape, rust, etc., generated during plumbing could result in air leaks and other defective operations. 4. Never use the valve with the 4(A) and 2(B) ports vented to the atmosphere. 5. When mounting a valve inside a control panel, or when energizing time is long, make adequate consideration for ventilation and other heat dissipation measures. 6. When adding or subtracting units in the manifold, or replacing a fitting block, be sure to tighten to within the specified tightening torque range. 1. Use air for the media. For the use of any other media, consult us. 2. Air used for the cylinder should be clean air that contains no deteriorated compressor oil, etc. Install an air filter (filtration of 40 µm or less) near the valve to remove collected liquid or dust. In addition, drain the air filter periodically. 3. When supply pressure is low, use piping for the 1(P) port with sufficient tube size. Lubrication Can be used without lubrication due to the factory lubricant (grease). When the pneumatic products require lubrication, use Turbine Oil Class 1 (ISO VG32) or the equivalent. In addition, cutting off oil feed while an operation is in progress could lead to malfunction due to the dissipation of the factory lubricant (grease). As a result, always keep the oil feed running continuously. However, use caution since excessive oil feed can also be a cause of malfunction. Avoid using spindle oil or machine oil. Atmosphere The product cannot be used when the media or ambient atmosphere contains any of the substances listed below. Organic solvents, phosphate ester type hydraulic oil, sulphur dioxide, chlorine gas, or acids, etc. Wiring After wiring, check that there is no error in the wiring connections. DIN rail mounting brackets As shown in below images, first make sure that the DIN rail mounting bracket is mounted on both sides of the manifold. Then securely connect the hooks of both sides to the DIN rail from above, and fix the position with DIN rail mounting screws. NOTE When the DIN rail mounting bracket is selected, the maximum is number of valves is 16 stations. DIN rail mounting screw Main unit mounting screw Tightening torque 0.74 N [0.55 ft・lbf] DIN rail mounting bracket Hooks (both sides) Fix with DIN rail mounting screw Tightening torque 0.74 N [0.55 ft・lbf] (Same for other side) 4 How to assemble and replace valves Assemble or replace the valves while the manifold body is not fixed. Refer to ③ and ④ when the customer is the one purchasing the end block and valves and assembling the manifold. ①Remove the mounting screws (bracket attached) from the four places (when adding valves, the two places on the top and bottom of where you are adding the valve) on the top and bottom of the valve to replace. Mounting screw (bracket attached) Gasket-side Gasket IBZR8Z-PJ (Sold separately) Air supply port Air supply port Left side Intermediate piping block Right side Same on other side Groove Mounting screw (bracket attached) Exhaust port (Integrated muffler) End block Protrusion ②T he valve and end block can be removed by opening them diagonally and pulling up. Open diagonally Pull up ③Assemble while diagonally aligning the positions of the indents and protrusions of the new valve. Align the indents and protrusions Close ④After attaching, fix it with a mounting screws. (Recommended tightening torque: 0.49 N • m [0.36 ft • lbf]) [Caution] ● Always turn off the power and the air supplies before starting work. Also, be sure to proceed after checking that all air from inside the manifold is vented. ● The maximum number of units that can be connected in a series is 20, including intermediate piping blocks. ● Be careful that the gasket is not pinched or does not fall out. ● Before supplying air to the manifold, be sure to check that the connections that were made between each valve and end block are secure. ● We recommend adding intermediate piping blocks 「IBZR8Z-PJ(-PJ3/8)」 if needed, when there is a large number of valves or a large number of valves simultaneously supplying air to the secondary side. Also, be careful of actuator malfunctions caused by the exhaust pressure. Furthermore, both intermediate piping blocks 「IBZR8Z-PJ(-PJ3/8)」 and valves can be added using the same procedure. ● For muffler exhaust type, before use, confirm that there is no exhaust noise or increase in pressure in the control panel when it is sealed. ● Air leakage from valves is not zero. For questions regarding the allowable amount of leakage, contact our sales office. [Warranty Period] ● The warranty period for this product is 12 months from the date of delivery. However, failure, loss of performance, or loss of function due to normal degradation is outside the scope of warranty, even if it is within the warranty period. 5 iB-ZERO Specifications Model Item IBZR8-4E1 Number of positions Number of ports Valve function Operation system Flow rate characteristics 5 Single solenoid Medium 3 Sonic conductance C dm /(s·bar) Effective cross section area [Cv value] Note 1 2 mm [Cv] Connection port size IBZR8-4E2 2 positions Double solenoid Air Internal pilot type mm J42:0.8、J62:1.6、J82:2 in J5/32:0.8、J1/4:1.6、J5/16:2 mm J42:4〔0.22〕、J62:8〔0.44〕、J82:10〔0.56〕 in J5/32:4〔0.22〕、J1/4:8〔0.44〕、J5/16:10〔0.56〕 mm Supply port φ10 [0.394]Note 2, outlet port φ4 [0.157], φ6 [0.236], φ8 [0.315] in Lubrication Supply port 3/8、outlet port 5/32、1/4、5/16 Not required Operating pressure range MPa [psi] Proof pressure MPa [psi] Operating temperature range (atmospheric and medium) ℃ [℉] Response time Note 3 on/off time ms Maximum operating frequency Hz 0.2 to 0.7 [29 to 102] 1.05 [152] 15/30 or less 5 to 50 [41 to 122] 5 m/s2 [G] Shock resistance Mounting direction 30 or less 294.2 [30] Unrestricted Notes 1: The effective cross section values are calculated values, and are not measured values. 2: Only when the intermediate piping block with quick fitting exhaust port is selected. 3: The valve when air pressure is 0.5 MPa [73 psi]. Electrical Specifications Rated voltage Item Applicable voltage range Current (when rated voltage applied) Power consumption Allowable circuit leakage current Type of insulation Insulation resistance Note Color of LED indicator Surge protection (standard equipment) V mA W mA MΩ Mass 24 VDC 21.6 to 26.4 (24±10%) 23 0.55 1.0 B type 100 or over Red Flywheel diode Note: Value at 500 VDC Megger Remark: Specification values are based on Koganei test standards. g [oz] Model IBZR8-4E1 IBZR8-4E2 Mass mm J42: 59 [2.08], J62: 60 [2.12], J82: 63 [2.22] in J5/32:59[2.08]、J1/4:60[2.12]、J5/16:63[2.22] mm J42: 75 [2.65], J62: 75 [2.65], J82: 78 [2.75] in J5/32:75[2.65]、J1/4:75[2.65]、J5/16:78 [2.75] IBZR8Z-E (end block) 81 [2.86] IBZR8Z-PJ 50 [1.76] IBZR8Z-EJ 84 [2.96] IBZR8Z-E3/8 IBZR8Z-PJ3/8 IBZR8Z-E3/8J IBZR8Z-PJJ IBZR8Z-PJ3/8J 81 [2.86] 50 [1.76] 84 [2.96] 53 [1.87] 53 [1.87] 6 Order codes ● Single valve unit (The single valve unit cannot be used alone.) ■ Valve specifications ■ Specifications for fittings of pipe ports -J42:quick fitting for φ4 [0.157] tubes -J62:quick fitting for φ6 [0.236] tubes -J82:quick fitting for φ8 [0.315] tubes -J5/32:quick fitting for 5/32 in. tubes -J1/4 :quick fitting for 1/4 in. tubes -J5/16:quick fitting for 5/16 in. tubes -4E1: 5-port, 2-position single solenoid -4E2: 5-port, 2-position double solenoid Single solenoid 14 (SA) Double solenoid 14 (SA) 5 (R1) 1 (P) 3 (R2) 4 (A) 2 (B) 4 (A) 2 (B) ■ Wiring specification L type plug connector L type plug connector L type plug connector Lead wire 300 mm [11.8 in] Lead wire 1000 mm [39 in] Lead wire 3000 mm [118.1 in] -PL 5 (R1) 1 (P) 3 (R2) -PL1 -PL3 L type plug connector No connector 12 (SB) -PLN Model Valve specifications IBZR8 -4E1 -4E2 Specifications for fittings of pipe ports -J42 -J62 -J82 Wiring specification -PL -PL1 -PL3 -J5/32 -J1/4 -J5/16 Voltage -PLN -CPL Note 1 -CPL1 Note 2 -CPL3 Note 3 24 VDC※ Note 1: Common connector assembly EAZ-PB is attached. 2: Common connector assembly EAZ-PB1 is attached. 3: Common connector assembly EAZ-PB3 is attached. Remarks: The gasket is installed in the valve body. Two mounting screws (bracket attached) are provided with the valve body. ※ For questions regarding support for 5-V, 6-V, and 12-V DC products, contact our sales office. ●Manifold ■ Specifications for fittings of pipe ports ■ Valve specifications Left side ■ Manifold format -J42: quick fitting for φ4 [0.157] tubes -J5/32: quick fitting for 5/32 in. tubes -4E1: 5-port, 2-position single solenoid -J62: quick fitting for φ6 [0.236] tubes -J1/4: quick fitting for 1/4 in. tubes -4E2: 5-port, 2-position double solenoid -J82: quick fitting for φ8 [0.315] tubes -J5/16: quick fitting for 5/16 in. tubes -PJ: Intermediate piping block for Φ10 mm tube -PJ3/8: Intermediate piping block for 3/8 inch tube ■ Wiring specification -PJJ: Intermediate piping block with quick fitting exhaust L type plug connector L type plug connector L type plug connector L type plug connector port for Φ10 mm tube Lead wire 300 mm [11.8 in] Lead wire 1000 mm [39 in] Lead wire 3000 mm [118.1 in] No connector -PJ3/8J: Intermediate piping block with quick fitting exhaust Right side port for 3/8 inch tube N: Finished product has each valve connected ■Mounting (fixed with mounting screw (bracket Blank: Direct mounting attached)) -DN: With DIN rail mounting bracket Note 1,Note 3 NS: Semi-finished product before each valve is connectedNote 1 *Mounting screws (bracket attached) must be used to connect and fix each valve before use. (mounting screw (bracket attached) provided) Model -PL Pre-wired positive common terminalNote 6 Lead wire 300mm Blank: Quick fiting for φ10mm tube -J3/8: Quick fiting for 3/8 inch tube -J:1 ( P ), 3 ( R ) quick fitting for Φ10 mm tube -J3/8J :1 ( P ), 3 ( R ) quick fitting for 3/8 inch tube Number of valves Manifold format 1 ・ ・ ・ 20(16)Note 1 -PL3 Pre-wired positive common terminalNote 6 Lead wire 1000mm -PLN Pre-wired positive common terminalNote 6 Lead wire 3000mm ■Piping block(End block at right side) Mounting Piping block Stations -CPL Model Manifold model IBZR8M -PL1 Valve specifications Specifications for fittings of pipe ports Wiring specification -CPL3 Voltage Model of mounted valve Blank N NSNote 2 -CPL1 Blank -DN Note 1、 Note 3 -J3/8Note 8 -J -J3/8JNote 8 stn. 1 ・ ・ ・ stn.□ Note 4 IBZR8 -4E1 -4E2 -PL -CPLNote 6 -J42 -J5/32 Note 8 -PL1 -CPL1 -J62 -J1/4 Note 8 -PL3 -CPL3 DC24VNote 7 -J82 -J5/16 Note 8 -PLNNote 5 (If an intermediate piping block is mounted on the specified station) -PJ -PJ3/8Note 8 -PJJ -PJ3/8JNote 8 Note 1: Note1: The maximum number of valves is 20 stations. When the DIN rail mounting bracket is selected, the maximum is 16 stations. 2: After doing connections, before supplying air to the manifold, be sure to check that the connections that were made between each valve and end block are secure. 3: Please separately prepare the DIN rail. When -NS is selected for the maniflod format, the DIN rail mounting brackets will be attached parts. 4: Valve positions are counted from the left side of the manifold. 5: Common connector assemblies are available for common wiring connections. For details, see page ③. 6: W hen connecting common wires between double solenoid valves on the 12 (SB) side, connections are possible between double solenoid valves if 1single solenoid valve is mounted between them, or even if 1 intermediate piping block is mounted between them. However, connections cannot be done if there are two or more, due to the relative length of the branch wires for common connections. 7: For questions regarding support for 5-V, 6-V, and 12-V DC products, contact our sales office. 8: (mm) fitting and (in.) fitting valves cannot be mixed in the same manifold. 7 Order codes ● Additional parts (available separately) DIN rail mounting bracket IBZR8Z-DN IBZR8Z-GS (4 mounting screws included) NOTE Set of brackets and mounting screws Gasket DIN rail DIN - IBZR8Z-KN DIN-□ (Unit: 1 pcs) (Units: 2 pcs) (Units: 1) When using DIN rail mounting brackets, the maximum number of valves is 16 stations. End block (left-right set) Length of DIN rail 125:125mm 150:150mm 175:175mm 200:200mm 225:225mm 250:250mm 275:275mm 300:300mm Intermediate piping block IBZR8Z- A type: EAZ-PA□ IBZR8Z- 1(P)port quick fittings 1(P)port quick fittings E:quick fitting for φ10 [0.394] tube PJ:quick fitting for φ10 [0.394] tube E3/8:quick fitting for 3/8 in. tube PJ3/8:quick fitting for 3/8 in. tube B type: EAZ-PB□ (With 1 gasket and 2 connecting brackets attached) (With 1 gasket and 2 connecting brackets attached) 325:325mm 350:350mm 375:375mm 400:400mm 425:425mm 450:450mm 475:475mm 500:500mm * Black (−) Red (+) * Red (+) (For common wiring) Black (−) * C type: EAZ-PC□ End block with quick fitting exhaust port (left-right set) IBZR8Z- IBZR8Z1 (P) ,3 (P)port quick fittings EJ:quick fitting for φ10 [0.394] tube E3/8J:quick fitting for 3/8 in. tube (With 1 gasket and 2 connecting brackets attached) 1(P),3(P)port quick fittings PJJ:quick fitting for φ10 [0.394] tube PJ3/8J:quick fitting for 3/8 in. tube * example 1.type: EAZ-PB□ the relative length of the branch B wires for common wire connections, Red (+) (For common wiring) connections cannot be done if two or more Branch wire intermediate piping blocks are mounted Black (−) between valves. 2. When connecting common wires between double solenoid valves on the 12 (SB) side, C type: EAZ-PC□ connections are possible between double Redsolenoid (+) (For common solenoid valves if 1 single valvewiring) is mounted between them, or even Black if 1 (−) intermediate Red (+) A type B type B type B type B piping type C typeblock is mounted between them. However, connections Lead 300two mmor[11.8 in] cannotwire be length done if Blank: there are more, 1: 1000 mmbranch [39 in] due to the relative length of the 3: 3000 mm [118 in] wires for common connections. EAZ - Connector specification P : Connector, lead wire length 300 mm [11.8 in] P1 : Connector, lead wire length 1000 mm [39 in] P3 : Connector, lead wire length 3000 mm [118 in] PN : Connector, without lead wire (contacts included) EAZ-P, P1, P3, PN cannot be wired with the common connector assembly. * Black (−) Red (+) Lead wire length Blank: 300 mm [11.8 in]Black (−) 1: 1000 mm [39 in] 3: 3000 mm [118 in]Red (+) Connection NOTE Due to Common connector assembly EAZ - NOTE A type: EAZ-PA□ (With 1 gasket and 2 connecting brackets attached) Connector-related Red (+) (For common wiring) Intermediate piping block with quick fitting exhaust port * * Connector specification PA : Positive common A type, connector, lead wire length 300 mm [11.8 in] PA1 : Positive common A type, connector, lead wire length 1000 mm [39 in] PA3 : Positive common A type, connector, lead wire length 3000 mm [118 in] PB : Positive common B type, connector, lead wire length 300 mm [11.8 in] PB1 : Positive common B type, connector, lead wire length 1000 mm [39 in] PB3 : Positive common B type, connector, lead wire length 3000 mm [118 in] PC : Positive common C type, connector, lead wire length 300 mm [11.8 in] PC1 : Positive common C type, connector, lead wire length 1000 mm [39 in] PC3 : Positive common C type, connector, lead wire length 3000 mm [118 in] CPN : Positive common, connector, without lead wire (short bar and contacts included) * Connection example Branch wire Lead wire assembly (order made) with completed common connections Using lead wire assemblies with completed common connections reduces wiring. Order codes A type B type B type B type B type C type EAZ-1W - P For the EAZ-1W-6P□ Common wires Lead wire length Blank 300 mm [11.8 in] 1 1000 mm [39 in] 3 3000 mm [118 in] 〜 Number of units wired together 2: 2 connections 20: 20 connections Lead wire assembly with completed common connections NOTE Common wires Black Red Black Black Black Black Black Red (-) (+) (-) (-) (-) (-) (-) (+) Branch wire (red) 1. D ue to the relative length of the branch wires for common wire connections, connections cannot be done if two or more intermediate piping blocks are mounted between valves. 2. W hen connecting common wires between double solenoid valves on the 12 (SB) side, connections are possible between double solenoid valves if 1 single solenoid valve is mounted between them, or even if 1 intermediate piping block is mounted between them. However, connections cannot be done if there are two or more, due to the relative length of the branch wires for common connections. 8 Dimensions mm [in] ■ Single valve unit (With quick fittings for mm tubes) 35 [1.378] IBZR8-4E2-J□-PL 5-port single solenoid 15 [0.591] (300 [11.8]) 10 [0.394] 30 [1.181] 10.5 [0.413] Manual override 2 (B) port 131.6 [5.18] 82 [3.228] 4 (A) port 2 (B) port Fitting -J42: φ4 [0.157] -J62: φ6 [0.236] -J82: φ8 [0.315] -J42: (2.6 [0.102]) -J62: (3 [0.118]) -J82: (4.7 [0.185]) 15 [0.591] (300 [11.8]) 10 [0.394] 4 (A) port 15 [0.591] 28.3 [1.114] 102 [4.016] 77.2 [3.039] Manual override 5-port double solenoid 35 [1.378] 30 [1.181] 10.5 [0.413] 15 [0.591] IBZR8-4E1-J□-PL -J42: (2.6 [0.102]) -J62: (3 [0.118]) -J82: (4.7 [0.185]) Fitting -J42: φ4 [0.157] -J62: φ6 [0.236] -J82: φ8 [0.315] 2 mounting screws provided 2 mounting screws provided Exhaust port (Integrated muffler) 20 [0.787] 1P 72.3 [2.846] 20 [0.787] ■Intermediate piping block with quick fitting exhaust port (Single unit) IBZR8Z-PJJ(With quick fittings for mm tubes) 72.3 [2.846] ■ Intermediate piping block (single unit) IBZR8Z-PJ(With quick fittings for mm tubes) (Same position on other side) 9 (5.3 [0.209]) 2 mounting screws provided 35 [1.378] Exhaust port (Integrated muffler) 35 [1.378] (5.3 [0.209]) 3R 2 mounting screws provided Dimensions mm [in] ■ Manifold IBZR8M□N (With quick fittings for mm tubes) Unit dimensions Number of units L 4.5 [0.177] LED indicator P 22.5 15 [0.591] Manual override 17.5 [0.886] (pitch) [0.689] 4 (A) port 2 (B) port 4.5 [0.177] 15 [0.591] (300 [11.8]) 30 [1.181] 4-φ4.2 [0.165] (Oval hole) (Mounting hole) 1 (P) port 3 85 [3.346] 76 [2.992] 15 [0.591] 5 Fitting (φ6 [0.236]) 25 [0.984] (5.3 [0.209]) stn. 1 stn. 2 stn. 3 stn. 4 15 [0.591] 13 [Mounting example] IBZRM4N stn.1 IBZR8-4E1-J42-PL 24 VDC stn.2 IBZR8-4E1-J62-PL 24 VDC stn.3 IBZR8-4E1-J82-PL 24 VDC stn.4 IBZR8-4E2-J82-PL 24 VDC 106 [4.2] 145 [5.7] 136 [5.4] 160 [6.3] 12 Mounting screw 115 [4.5] 8 7 11 Fitting (φ8 [0.315]) 100 [3.9] 91 [3.583] 130 [5.1] 10 35.8 [1.409] 28.3 [1.114] Fitting (φ4 [0.157]) 70 [2.756] 61 [2.402] 6 14 4.9 [0.193] 62 [2.441] 55 [2.165] 46 [1.811] 2 4 Exhaust port (Integrated muffler) PNote 1 9 6 [0.236] 72.3 [2.846] 35.3 [1.39] -J42: (2.6 [0.102]) -J62: (3.0 [0.118]) -J82: (4.7 [0.185]) 5.2 [0.205] 102 [4.016] 77.2 [3.039] 131.6 [5.18] Fitting (φ10 [0.394]) 10.8 [0.425] LNote 175 [6.9] 190 [7.5] 205 [8.1] 220 [8.7] 235 [9.3] 250 [9.8] 121 [4.8] 151 [5.9] 166 [6.5] 181 [7.1] 196 [7.7] 211 [8.3] 226 [8.9] 241 [9.5] 15 265 [10.4] 256 [10.1] 17 295 [11.6] 286 [11.3] 16 280 [11] 271 [10.7] 18 310 [12.2] 301 [11.9] 20 340 [13.4] 19 325 [12.8] 316 [12.4] 331 [13] Note:I f intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. If intermediate piping block is mounted (Model: IBZR8-PJ) 20 [0.787] Exhaust port (Integrated muffler) Intermediate piping block 1 (P) port Fitting (φ10 [0.394]) Exhaust port (Integrated muffler) (Same position on other side) 10 Dimensions mm [in] ■Manifold (With DIN rail mounting bracket) IBZR8M□N-DN (With quick fitting for mm tubes) Q 12 [0.472] LED indicator L 22.5 15 [0.591] Manual override 17.5 [0.886] (Pitch) [0.689] 30 [1.181] 10.8 [0.425] Exhaust port (Integrated muffler) 1 (P) Port 47 [1.850] 28.3 [1.114] 15 [0.591] 72.3 [2.846] 2 35.8 [1.409] 6 7 8 9 10 11 Mounting screw 12 s t n. 1s t n. 2s t n. 3s t n. 4 25 [0.984] (7.5) [0.295] 35.3 [1.390] 15 [0.591] (5.3) [0.209] 4.9 [0.193] 12.7 [0.500] 1 3 Fitting(φ8 [0.315]) Fitting Fitting (φ4 [0.157]) (φ6[0.236]) DIN rail mounting bracket (Attached when NS is selected) 35 [1.378] 5.5 [0.217] 25 [0.984] 20.5 [0.807] DIN rail mounting hole dimension If intermediate piping block is mounted (Model: IBZR8-PJ) 20 [0.787] Exhaust port (Integrated muffler) 1 (P) port Fitting (φ10 [0.394]) Exhaust port (Integrated muffler) (Same position on other side) 13 14 15 LNote 55[2.165] 70[2.756] Q Note 79[3.110] 94[3.701] 85[3.347] 109[4.291] 100[3.937] 124[4.882] 115[4.528] 139[5.472] 130[5.118] 154[6.063] 145[5.709] 169[6.654] 160[6.299] 184[7.244] 175[6.890] 199[7.835] 190[7.480] 214[8.425] 205[8.071] 229[9.016] 220[8.661] 244[9.606] 235[9.252] 259[10.197] 250[9.843] 274[10.787] 265[10.433] 289[11.378] 16 280[11.023] 304[11.969] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the [Mounting example] intermediate piping blocks in IBZR8M4N-DN L and P. stn.1 IBZR8-4E1-J42-PL DC24V stn.2 IBZR8-4E1-J62-PL DC24V stn.3 IBZR8-4E1-J82-PL DC24V stn.4 IBZR8-4E2-J82-PL DC24V (12.5) [0.492] Intermediate piping block Number of units 5 -J42: (2.6 [0.102]) -J62: (3.0 [0.118]) -J82: (4.7 [0.185]) DIN-□ Unit dimensions 4 ■DIN rail 11 (300) [11.8] Fitting(φ10 [0.394]) 77.2 [3.039] 131.6 [5.18] 102 [4.016] 4 (A) Port 2 (B) Port 15 [0.591] mm [in] ■Manifold (Exhaust from quick fitting) IBZR8M□N-J (With quick fitting for mm tubes) -J Unit dimensions L 4.5[0.177] LED indicator 22.5 [0.886] 15 [0.591] (Pitch) Number of units 4.5[0.177] P Manual override (300 [11.8]) 16.5 16 [0.650] [0.630] 4 (A) Port 30 [1.181] 10.8 [0.425] 4-φ4.2 [0.165] (Oval hole) (Mounting hole) 1 (P) port 2 (B) Port 23.4 [0.921] 17.5 [0.689] 15 [0.591] 62 [2.441] 28.3 [1.114] 3R 4 Fitting(φ6[0.236]) 15 [0.591] 6 [0.236] s t n.3;IBZR8-4E1-J82-PL DC24V s t n.4;IBZR8-4E2-J82-PL DC24V 76[2.992] 91[3.583] 136[5.354] 9 175[6.890] 8 130[5.118] 160[6.299] 190[7.480] 205[8.071] 220[8.661] 121[4.764] 151[5.945] 166[6.535] 181[7.126] 196[7.717] 211[8.307] 235[9.252] 226[8.898] 15 265[10.433] 256[10.079] 17 295[11.614] 286[11.260] 16 IBZR8M4N-J IBZR8M4N-J stn.1 IBZR8-4E1-J42-PL DC24V s t n.1;IBZR8-4E1-J42-P L DC24V stn.2 IBZR8-4E1-J62-PL DC24V stn.3 IBZR8-4E1-J82-PL DC24V s t n.2;IBZR8-4E1-J62-P L DC24V stn.4 IBZR8-4E2-J82-PL DC24V 85[3.347] 100[3.937] 46[1.811] 61[2.402] 145[5.709] 13 [Mounting example] 搭載例 70[2.756] 7 6 250[9.843] 280[11.023] 18 310[12.205] 20 340[13.386] 19 25 [0.984] 55[2.165] P Note 106[4.173] 12 Mounting screw LNote 115[3.937] 11 Fitting(φ8 [0.315]) (5.3 [0.209]) -J42: (2.6 [0.102]) -J62: (3.0 [0.118]) -J82: (4.7 [0.185]) 3 10 s t n.1 s t n.2 s t n.3 s t n.4 35.3 [1.39] 2 14 4.9 [0.193] 72.3 [2.846] 1P 5.2 [0.205] 102 [4.016] 77.2 [3.039] 1 (P) port Fitting(φ4 [0.157]) 1 5 Fitting (2-φ10 [0.394]) 325[12.795] 241[9.488] 271[10.670] 301[11.850] 316[12.441] 331[13.031] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. *When NS, NS-DN is selected, this must be connect by the customer before usage. For NS, the connecting brackets, for NSDN the the connecting brackets and DIN rail mounting brackets will be attached. *When –DN is selected, available stations will be from 1 to 16 stations. When the intermediate piping block with quick fitting exhaust port is installed. (Model:IBZR8-PJJ) 連数別寸法一覧表20 [0.787] 1 (P) port 17.5 [0.689] Fitting(2-φ10 [0.394]) 連数 L寸法(注2) P寸法(注2) 注1) NS、NS-DNを選択した場合は、 ご使用前にお客様にて連結してください。 1 55 46 NSの場合は連結金具が、NS-DNの場合は連結金具、 2 70 61 DINレール取付金具が添付されています。 3 85 76 注2) 中間配管ブロックを搭載した場合は、 L、 P寸法に 4 100 91 中間配管ブロックの数量×20mmを加算してください。 5 115 106 注3) -DN選択の場合、連数は1〜16連とする。 6 130 121 3(R) port 7 145 block 136 Intermediate piping with 8 160 port 151 quick fitting exhaust 9 175 166 10 190 181 11 205 196 12 220 211 13 235 226 14 250 241 15 265 256 16 280 271 17 295 286 18 310 301 19 325 316 20 340 331 23.4 [0.921] 131.6 [5.18] R8M Dimensions 1P 3R 12 mm [in] 形式 ■Manifold (With DIN rail mounting bracket,Exhaust from quick fitting) IBZR8M -DN-J IBZR8M□N-DN-J (With quick fitting for mm tubes) Unit dimensions Q 12 [0.472] Number of units LNote 1 55[2.165] L LED indicator 22.5 [0.886] 15 [0.591] (Pitch) Manual override 16.5 [0.650] 16 [0.630] 4 (A) Port (300) [11.8] 30 [1.181] 10.8 [0.425] 2 3 1 (P) Port 2 (B) Port 3R Fitting (φ4 [0.157]) 35.3 [1.390] IBZR8M4N-DN-J IBZR8M4N-DN-J stn.1 IBZR8-4E1-J42-PL DC24V s t n.1;IBZR8-4E1-J42-PL DC24V stn.2 IBZR8-4E1-J62-PL DC24V s t n.2;IBZR8-4E1-J62-P L DC24V stn.3 IBZR8-4E1-J82-PL DC24V stn.4 IBZR8-4E2-J82-PL DC24V s t n.3;IBZR8-4E1-J82-P L DC24V (7.5) [0.295] 1P 3R 154[6.063] 175[6.890] 199[7.835] 15 [Mounting 搭載例 example] 139[5.472] 9 14 DIN rail mounting bracket (Attached when NS is selected) 109[4.291] 124[4.882] 169[6.654] 13 s t n.4;IBZR8-4E2-J82-PL DC24V (注2) Q寸法 79 When the intermediate piping block with 94 109 quick fitting exhaust port is installed. 124 (Model:IBZR8-PJJ) 139 154 1 (P) port 20 [0.787] 169 184 Fitting(2-φ10 [0.394]) 199 214 229 244 259 注1) NSを選択した場合は、 ご使用前にお客様にて連結してください。 連結金具、DINレール取付金具は添付されています。 274 注2) 中間配管ブロックを搭載した場合は、L、Q寸法に 289 中間配管ブロックの数量×20mmを加算してください。 304 3(R) port Intermediate piping block with quick fitting exhaust port 17.5 [0.689] 25 [0.984] (5.3) [0.209] -J42: (2.6 [0.102]) -J62: (3.0 [0.118]) -J82: (4.7 [0.185]) 15 [0.591] 79[3.110 94[3.701] 145[5.709] 12 Mounting screw 115[3.937] P Note 7 16 連数別寸法一覧表 13 130[5.118] 11 s t n.1 s t n.2 s t n.3 s t n.4 (注2) L寸法 55 70 85 100 115 130 145 160 175 190 205 220 235 250 265 280 6 10 Fitting(φ8 [0.315]) Fitting (φ6[0.236]) 85[3.347] 100[3.937] 8 23.4 [0.921] 17.5 [0.690] 47 [1.850] 28.3 [1.114] 15 [0.591] 4.9 [0.193] 72.3 [2.846] 1P 12.7 [0.500] 102 [4.016] 77.2 [3.039] 131.6 [5.18] 3(R)Port 70[2.756] 4 5 Fitting(2-φ10 [0.394]) 23.4 [0.921] 数 Dimensions 160[6.299] 190[7.480] 205[8.071] 220[8.661] 235[9.252] 250[9.843] 265[10.433] 280[11.023] 184[7.244] 214[8.425] 229[9.016] 244[9.606] 259[10.197] 274[10.787] 289[11.378] 304[11.969] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. *When NS, NS-DN is selected, this must be connect by the customer before usage.For NS, the connecting brackets, for NS-DN the the connecting brackets and DIN rail mounting brackets will be attached. *When –DN is selected, available stations will be from 1 to 16 stations. Dimensions mm [in] ■Single valve unit (With quick fittings for inch tubes) 35 [1.378] IBZR8-4E2-J□-PL 5-port single solenoid 15 [0.591] (300 [11.8]) 10 [0.394] 30 [1.181] 10.5 [0.413] Manual override 2 (B) port 131.6 [5.18] 82 [3.228] 4 (A) port 2 (B) port Fitting -J42: φ4 [0.157] -J62: φ6 [0.236] -J82: φ8 [0.315] -J42: (2.6 [0.102]) -J62: (3 [0.118]) -J82: (4.7 [0.185]) 15 [0.591] (300 [11.8]) 10 [0.394] 4 (A) port 15 [0.591] 28.3 [1.114] 102 [4.016] 77.2 [3.039] Manual override 5-port double solenoid 35 [1.378] 30 [1.181] 10.5 [0.413] 15 [0.591] IBZR8-4E1-J□-PL -J42: (2.6 [0.102]) -J62: (3 [0.118]) -J82: (4.7 [0.185]) Fitting -J42: φ4 [0.157] -J62: φ6 [0.236] -J82: φ8 [0.315] 2 mounting screws provided 2 mounting screws provided ■ Intermediate piping block (single unit) ■Intermediate piping block with quick fitting IBZR8Z-PJ3/8(With quick fittings for inch tubes) exhaust port (Single unit) IBZR8Z-PJ3/8J(With quick fittings for inch tubes) 20 [0.787] 1P 72.3 [2.846] Exhaust port (Integrated muffler) 72.3 [2.846] 20 [0.787] (Same position on other side) (5.3 [0.209]) 2 mounting screws provided 35 [1.378] Exhaust port (Integrated muffler) 35 [1.378] (5.3 [0.209]) 3R 2 mounting screws provided 14 Dimensions mm [in] ■Manifold IBZR8M□N-J3/8 (With quick fittings for inch tubes) 4.5 [0.177] LED indicator L P 22.5 15 [0.591] Manual override 17.5 [0.886] (Pitch) [0.689] 4 (A) Port 2 (B) Port 4.5 [0.177] 15 [0.591] Unit dimensions Number of units (300) [11.8] 30 [1.181] 4-φ4.2 [0.165] (Oval hole) (Mounting hole) 1 (P) port Exhaust port (Integrated muffler) 3 4 5 35.8 [1.409] 25 [0.984] (Model: IBZR8-PJ3/8) 20 [0.787] Exhaust port (Integrated muffler) 1 (P) port Fitting (φ10 [0.394]) Exhaust port (Integrated muffler) (Same position on other side) IBZR8M4N-J3/8 stn.1 IBZR8-4E1-J5/32-PL DC24V stn.2 IBZR8-4E1-J1/4-PL DC24V stn.3 IBZR8-4E1-J5/16-PL DC24V stn.4 IBZR8-4E2-J5/16-PL DC24V 76 [2.992] 91 [3.583] 145 [5.709] 136 [5.354] 9 175 [6.890] 12 [Mounting example] 85 [3.346] 100 [3.937] 46 [1.811] 61 [2.402] 7 6 13 130 [5.118] 160 [6.299] 190 [7.480] 205 [8.071] 220 [8.661] 121 [4.764] 151 [5.945] 166 [6.535] 181 [7.126] 196 [7.717] 211 [8.307] 235 [9.252] 226 [8.898] 15 265 [10.433] 256 [10.079] 17 295 [11.614] 286 [11.260] 14 16 (5.3) [0.209] 15 [0.591] 70 [2.756] 106 [4.173] 11 Mounting screw 55 [2.165] P Note 115 [4.528] 10 Fitting(5/16) If intermediate piping block is mounted 15 2 15 [0.591] 62 [2.441] 4.9 [0.193] Fitting (1/4) 6 [0.236] 35.3 [1.39] -J5/32: (2.6) [0.102] -J1/4: (3.4) [0.134] -J5/16: (4.7) [0.185] Fitting (5/32) stn. 1 stn. 2 stn. 3 stn. 4 Intermediate piping block 1 8 28.3 [1.114] 72.3 [2.846] 5.2 [0.205] 77.2 [3.039] 131.6 [5.18] 102 [4.016] Fitting(3/8) 10.8 [0.425] LNote 250 [9.843] 280 [11.024] 18 310 [12.205] 20 340 [13.386] 19 325 [12.795] 241 [9.488] 271 [10.669] 301 [11.850] 316 [12.441] 331 [13.031] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. Dimensions mm [in] ■Manifold (With DIN rail mounting bracket) IBZR8M□N-DN-J3/8 (With quick fittings for inch tubes) Q L 12 LED indicator [0.472] 22.5 15[0.591] Manual override 17.5 15 [0.689][0.591] [0.886](Pitch) 10.8[0.425] 1 (P) Port 35.8[1.409] Exhaust port (Integrated muffler) Fitting (5/16) Fitting (1/4) Mounting screw s t n. 1s t n. 2s t n. 3s t n. 4 Number of units LNote Q Note 1 55 [2.165] 79 [3.110] 2 70 [2.756] 94 [3.701] 3 85 [3.346] 109 [4.291] 4 100 [3.937] 124 [4.882] 5 115 [4.528] 139 [5.472] 6 130 [5.118] 154 [6.063] 7 145 [5.709] 169 [6.654] 8 160 [6.299] 184 [7.244] 9 175 [6.890] 199 [7.835] 10 190 [7.480] 214 [8.425] 11 205 [8.071] 229 [9.016] 12 220 [8.661] 244 [9.606] 13 235 [9.252] 259 [10.197] 14 250 [9.843] 274 [10.787] 16 280 [11.024] 304 [11.969] 25 [0.984] DIN rail mounting bracket (Attached when NS is selected) [Mounting example] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. IBZR8M4N-DN-J3/8 stn.1 IBZR8-4E1-J5/32-PL DC24V stn.2 IBZR8-4E1-J1/4-PL DC24V stn.3 IBZR8-4E1-J5/16-PL DC24V stn.4 IBZR8-4E2-J5/16-PL DC24V (7.5) [0.295] 15[0.591] Unit dimensions 15 265 [10.433] 289 [11.378] (5.3) [0.209] 47 [1.85] 72.3 [2.246] 28.3 15 [1.114] [0.591] 4.9[0.193] Fitting (5/32) -J5/32: (2.6) [0.102] -J1/4: (3.4) [0.134] (4.7) [0.185] 35.3[1.39] -J5/16: 12.7[0.5] 102 [4.016] 30[1.181] Fitting (3/8) 77.2 [3.039] 131.6 [5.18] 4 (A) Port 2 (B) Port (300) [11.811] ■DIN rail DIN-□ 35 [1.378] 25 [0.984] 5.5 [0.217] (12.5) [0.492] 20.5 [0.807] DIN rail mounting hole dimension If intermediate piping block is mounted (Model: IBZR8-PJ3/8) 20 [0.787] Exhaust port (Integrated muffler) Intermediate piping block 1 (P) port Fitting (φ10 [0.394]) Exhaust port (Integrated muffler) (Same position on other side) 16 Dimensions mm [in] 形式 ■Manifold (Exhaust from quick fitting) -J3/8J quick fittings for inch tubes) IBZR8M IBZR8M□N-J3/8J(With L 4.5[0.177] LED indicator (4.5)[0.177] P 15[0.591] 22.5 [0.886] (Pitch) Manual override 16.5 16 [0.650] [0.630] 4 (A) Port (300) [11.811] 4-φ4.2 [0.165] (Oval hole) (Mounting hole) 1 30[1.181] 10.8 [0.425] 1 (P) Port 2 (B) Port Fitting (5/32) 2 5 (5.3)[0.209] -J5/32: (2.6) [0.102] -J1/4: (3.4) [0.134] -J5/16: (4.7) [0.185] s t n.1;IBZR8-4E1-J42-PL DC24V s t n.2;IBZR8-4E1-J62-PL DC24V 6[0.236] 35.3[1.39] 搭載例 s t n.3;IBZR8-4E1-J82-PL DC24V s t n.4;IBZR8-4E2-J82-PL DC24V [Mounting example] IBZR8M4N-J3/8J stn.1 IBZR8-4E1-J5/32-PL DC24V stn.2 IBZR8-4E1-J1/4-PL DC24V stn.3 IBZR8-4E1-J5/16-PL DC24V stn.4 IBZR8-4E2-J5/16-PL DC24V 連数別寸法一覧表 17.5 [0.689] (注2) P寸法 (注2) L寸法 55 46 70 61 85 76 100 91 115 106 When the intermediate piping block with 130 121 quick fitting exhaust port is installed. 145 136 160 151 (Model:IBZR8-PJ3/8J) 175 166 190 181 1 (P) port 205 196 20 [0.787] 220 211 Fitting(2-3/8) 注1) NS、 NS-DNを選択した場合は、 ご使用前にお客様にて連結 してください。 235 226 NSの場合は連結金具が、 NS-DNの場合は連結金具、DINレール取付金具が添付されています。 250 241 注2) 中間配管ブロックを搭載した場合は、 L、 P寸法に 中間配管ブロックの数量×20mmを加算してください。 265 256 注3) -DN選択の場合、連数は1〜16連とする。 280 271 1P 295 286 310 301 325 316 3R 340 331 23.4 [0.921] 連数 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Intermediate piping block with quick fitting exhaust port 17 3(R) port 91 [3.583] 9 175 [6.890] 10 130 [5.118] 160 [6.299] 190 [7.480] 205 [8.071] 220 [8.661] 121 [4.764] 151 [5.945] 166 [6.535] 181 [7.126] 196 [7.717] 211 [8.307] 235 [9.252] 226 [8.898] 15 265 [10.433] 256 [10.079] 17 295 [11.614] 286 [11.260] 14 IBZR8M4N-J3/8J 76 [2.992] 136 [5.354] 13 25[0.984] 85 [3.346] 100 [3.937] 46 [1.811] 61 [2.402] 145 [5.709] 12 15[0.591] 70 [2.756] 7 11 s t n.1 s t n.2 s t n.3 s t n.4 55 [2.165] P Note 106 [4.173] 8 Mounting screw LNote 115 [4.528] 6 Fitting (5/16) Fitting (1/4) 1 4 23.4[0.921] 17.5[0.689] 15 [0.591] 62 [2.441] 28.3[1.114] 3R Number of units 3 1P 4.9 72.3 [2.246] 5.2 102 [4.016] 3(R)Port 77.2 [3.039] 131.6 [5.18] Fitting(2-3/8) Unit dimensions 16 250 [9.843] 280 [11.024] 18 310 [12.205] 20 340 [13.386] 19 325 [12.795] 241 [9.488] 271 [10.669] 301 [11.850] 316 [12.441] 331 [13.031] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. *When NS, NS-DN is selected, this must be connect by the customer before usage. For NS, the connecting brackets, for NSDN the the connecting brackets and DIN rail mounting brackets will be attached. *When –DN is selected, available stations will be from 1 to 16 stations. Dimensions mm [in] ■Manifold (With DIN rail mounting bracket,Exhaust from quick fitting) 形式 IBZR8M□N-DN-J3/8J (With quick fittings for inch tubes) -DN-J3/8J IBZR8M Q LED indicator 12 [0.472] Unit dimensions L 22.5[0.886] 15[0.591] Manual override (Pitch) 4 (A) Port 10.8 [0.425] 3 Fitting (1/4) (5.3)[0.209] -J5/32: (2.6) [0.102] -J1/4: (3.4) [0.134] -J5/16: (4.7) [0.185] 35.3[1.39] 154 [6.063] 169 [6.654] 184 [7.244] 205 [8.071] 229 [9.016] 14 [Mounting example] 搭載例 139 [5.472] 11 13 DIN rail mounting bracket (Attached when NS is selected) 160 [6.299] 109 [4.291] 124 [4.882] 199 [7.835] 16 25[0.984] 145 [5.709] 79 [3.110] 94 [3.701] 175 [6.890] 15 15[0.591] 115 [4.528] Q Note 9 12 s t n.1 s t n.2 s t n.3 s t n.4 85 [3.346] 130 [5.118] 10 Mounting screw 70 [2.756] 6 8 Fitting (5/16) 55 [2.165] 100 [3.937] 7 23.4[0.921] 17.5[0.689] 47 [1.850] 28.3 15 [1.114] [0.591] 4.9 [0.193] 72.3 [2.246] 12.7[0.500] 3R LNote 4 5 3(R)Port 1P Fitting (5/32) Number of units 1 2 Fitting(2-3/8) 77.2 [3.039] 102 [4.016] 30[1.181] 1(P)Port 2 (B) Port 131.6 [5.18] (300) [11.811] 16.5 16 [0.650] [0.630] 190 [7.480] 220 [8.661] 214 [8.425] 244 [9.606] 235 [9.252] 259 [10.197] 265 [10.433] 289 [11.378] 250 [9.843] 280 [11.024] 274 [10.787] 304 [11.969] Note:If intermediate piping blocks are mounted, add 20 mm [0.787 in] for each of the intermediate piping blocks in L and P. IBZR8M4N-DN-J3/8J IBZR8M4N-DN-J3/8J stn.1 IBZR8-4E1-J5/32-PL DC24V s t n.1;IBZR8-4E1-J42-P L DC24V DC24V stn.2 IBZR8-4E1-J1/4-PL s t n.2;IBZR8-4E1-J62-P L DC24V DC24V stn.3 IBZR8-4E1-J5/16-PL stn.4 IBZR8-4E2-J5/16-PL s t n.3;IBZR8-4E1-J82-P L DC24V DC24V (7.5) [0.295] s t n.4;IBZR8-4E2-J82-PL DC24V 連数別寸法一覧表 (注2) Q寸法 79 94When the intermediate piping block with 109 124 quick fitting exhaust port is installed. 139 (Model:IBZR8-PJ3/8J) 154 注1) NSを選択した場合は、 ご使用前にお客様にて連結してください。 169 連結金具、DINレール取付金具は添付さ れています。 1 (P) port 20 [0.787] 184 注2) 中間配管ブロックを搭載した場合は、L、Q寸法に 中間配管ブロックの数量×20mmを加算してください。 199 Fitting(2-3/8) 214 229 244 259 1P 274 289 304 3R 17.5 [0.689] (注2) L寸法 55 70 85 100 115 130 145 160 175 190 205 220 235 250 265 280 23.4 [0.921] 連数 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Intermediate piping block with quick fitting exhaust port 3(R) port 18 Limited Warranty KOGANEI CORP. warrants its products to be free from defects in material and workmanship subject to the following provisions. Warranty Period The warranty period is 180 days from the date of delivery. Koganei Responsibility Limitations If a defect in material or workmanship is found during the warranty period, KOGANEI CORP. will replace any part proved defective under normal use free of charge and will provide the service necessary to replace such a part. • This warranty is in lieu of all other warranties, expressed or implied, and is limited to the original cost of the product and shall not include any transportation fee, the cost of installation or any liability for direct, indirect or consequential damage or delay resulting from the defects. • • • • URL http://www.koganei.co.jp E-mail: [email protected] OVERSEAS DEPARTMENT 3-11-28, Midori-cho, Koganei City, Tokyo 184-8533, Japan Tel: 81-42-383-7271 Fax: 81-42-383-7276 KOGANEI INTERNATIONAL AMERICA, INC. 39300 Civic Center Dr., Suite 280, Fremont, CA 94538, U.S.A. Tel : 1-510-744-1626 Fax : 1-510-744-1676 SHANGHAI KOGANEI INTERNATIONAL TRADING CORPORATION Room 2606-2607, Tongda Venture Building No.1, Lane 600, Tianshan Road, Shanghai, 200051, China Tel: 86-21-6145-7313 Fax: 86-21-6145-7323 TAIWAN KOGANEI TRADING CO., LTD. Rm. 2, 13F., No88, Sec. 2, Zhongxiao E. Rd., Zhongzheng Dist., Taipei City 100, Taiwan (ROC) Tel: 886-2-2393-2717 Fax: 886-2-2393-2719 KOGANEI KOREA CO., LTD. 6F-601, Tower Bldg., 1005, Yeongdeo-dong, Giheung-gu, Yongin-si, Gyeonggi-do, 446-908, Korea Tel: 82-31-246-0414 Fax: 82-31-246-0415 KOGANEI (THAILAND) CO., LTD. 3300/90, Tower B, Elephant Tower,16th Fl., Phaholyothin Road, Chomphon, Chatuchak, Bangkok 10900, Thailand Tel: 66-2-937-4250 Fax: 66-2-937-4254 KOGANEI ASIA PTE. LTD. 69 Ubi Road 1, #05-18 Oxley Bizhub, Singapore 408731 Tel: 65-6293-4512 Fax: 65-6293-4513 12/’19 KG ©KOGANEI CORP. PRINTED IN JAPAN KOGANEI CORP. shall in no way be liable or responsible for injuries or damage to persons or property arising out of the use or operation of the manufacturer’s product. This warranty shall be void if the engineered safety devices are removed, made inoperative or not periodically checked for proper functioning. Any operation beyond the rated capacity, any improper use or application, or any improper installation of the product, or any substitution upon it with parts not furnished or approved by KOGANEI CORP., shall void this warranty. This warranty covers only such items supplied by KOGANEI CORP. The products of other manufacturers are covered only by such warranties made by those original manufacturers, even though such items may have been included as the components. The specifications are subject to change without notice. ">
Advertisement
Key features
- Quick fitting exhaust port
- Compact and lightweight
- Easy assembly
- Integrated muffler
- Intermediary piping block
Frequently asked questions
The IBZR8Z-PJ3/8J is an intermediate piping block that connects multiple iB-ZERO series 5-port solenoid valves in a manifold configuration.
The maximum number of units that can be connected in a series is 20, including intermediate piping blocks.
The recommended tightening torque for the mounting screws is 0.49 N • m [0.36 ft • lbf].