Quick Start Manual

AMAX panel

Table of contents

5.4.1

5.4.2

5.4.3

5.4.4

5.5

5.5.1

5.5.2

5.5.3

5.5.4

5.5.5

5.5.6

5.5.7

5.6

6

5

5.1

5.2

5.3

5.4

3

4

1

2

Safety

Short information

System overview

Connecting Modules and Devices

Programming and Operating the AMAX System

Option: Changing Menu Language

Accessing the Menus

Menu Navigation

Programming the AMAX System via Keypad

Setting Date and Time

Deleting a Zone

Enabling the RF Receiver for Wireless Communication

Setting up a Zone for an RF Device

Programming the AMAX Sytem via PC and USB

Installing the Programming Software

Connecting the PC and the AMAX Panel

Starting the Programming Software

Setting the COM Port

Option: Creating a New Customer

Configuring the Control Panel

Establishing a Direct Connection

Menu Programming

Technical Data

Table of Contents | en

3

17

18

21

22

32

14

14

14

14

15

7

10

11

11

11

11

12

12

12

13

13

4

6

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

4

en | Safety AMAX panel

1 Safety

Danger!

Electricity

Injuries due to electricity are possible if the system is not operated correctly or if the system is opened or modified not accordingly to this manual.

– Disconnect all Telecommunication Network Connectors before switching off the power.

– To switch off the power, make sure to have a circuit breaker available.

– Make sure that the system is switched off during the installation and wiring process.

– Only open or modify the system accordingly to this manual.

– Make sure to connect the system to a socket-outlet with a protective grounding contact.

– Only qualified installers /service personnel are allowed to install this system.

Danger!

Battery

Injuries due to electric shock, fire or explosion are possible if the battery is handled or connected incorrectly.

– Always handle the battery carefully and replace it carefully.

– Make sure that the grounding terminal is always connected and that N, L1 or xx are connected correctly.

– Make sure to first disconnect the positive wire of the battery when removing it from the system.

– Be careful when connecting the positive (red) wire and the "BATT +" port of the system.

Make sure not to short-circuit with the "BATT +" port of the AMAX panel or the housing to prevent electric arc from occurring.

Danger!

Electrostatic-sensitive components

Injuries due to electric shock are possible if anti-static steps are not followed.

!

!

– Always contact the grounding terminal before installing the system to discharge the possibly carried static electricity.

Caution!

Sensitive components

Damage of sensitive components is possible if the system is not handled carefully or if the system is opened or modified not accordingly to this manual.

– Always handle the system carefully.

– Only open or modify the system accordingly to this manual.

Caution!

Battery

Damage or contamination of the system is possible if the battery is not handled correctly or if the battery is not replaced on a regular basis.

– Only use a non-spillable battery.

– Place a label with the last replacement date on the battery.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

!

!

Safety | en

5

– Under normal conditions of use, replace the battery every 3-5 years.

– Recycle the battery after replacement according to local regulations.

Caution!

Installation

Damage or malfunction of the system is possible if the system is not mounted and installed correctly.

– Place the system inside the monitored area on a stable surface.

– Make sure to mount keypads on the inner side of the monitored area.

– Once the system is tested and ready to use, secure the enclosure door and additional enclosures with screws.

Caution!

Maintenance

Damage or malfunction of the system is possible if it is not maintained on a regular basis.

– It is recommended to test the system once a week.

– Make sure to get the system maintained four times a year.

– Only qualified installers /service personnel are allowed to maintain this system.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

6

en | Short information

2

AMAX panel

Short information

This Quick Start Guide contains information on how to get the system into operation easily and quickly. The guide describes the main steps required for basic system installation and setup of an AMAX panel together with one IUI-AMAX4-TEXT keypad and one RFRC-OPT

RADION receiver. The program tree structure is provided at the end of this guide.

Detailed information about installation of other modules and devices, advanced settings and programming can be found in the Installation Guide. For detailed operation information, please refer to the User Guide.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

3

PSTN

System overview | en

7

System overview

LCD / LED Keypad Text Keypad

Radion

DX2010

B426

Ethernet

GSM/

GPRS

DX4020G

B450

(B442/B443)

DX4010V2

GPRS

DX3010

Option Bus

AMAX 3000

AMAX 2100 / 3000

Video

A-Link Plus

Figure 3.1: AMAX 2100 / 3000 Overview

CMS

LCD / LED Keypad Text Keypad

PSTN

DX2010

B426

Ethernet

GSM/

GPRS

DX4020G

B450

(B442/B443)

DX4010V2

GPRS

Radion

Option Bus

DX3010

A-Link Plus

Figure 3.2: AMAX 3000 BE / 4000 Overview

CMS

Bosch Sicherheitssysteme GmbH Quick Start Manual

Video

2015.05 | 05 | F.01U.309.297

8

en | System overview

Wiring diagrams

AMAX panel

≤ 500mA

/ B450

Figure 3.3: Wiring diagram AMAX 2100 / 3000

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel System overview | en

9

R

B

G Y

TIP TH RH RING R B G Y

AUX1 AUX2 AUX2 AUX1

+12V

+12V

-

Bosch Option

AUX Power

Keypads:

IUI-AMAX4-TEXT

IUI-SOL-TEXT

IUI-AMAX3-LED16

IUI-AMAX3-LED8

1 =

2

=

3 =

4

=

5-16 Inst. Guide

Keypads:

IUI-AMAX-LED8

IUI-AMAX-LCD8

1

2

=

=

I/O Moduls:

DX2010 Adr. 103 - 108

DX3010 Adr. 150 - 151

DX4010 Adr. 253

Factory

Default

Communicators:

DX4020G Adr. 134

B426 / B450 Adr. 134(6) / 250(9)

RF Receiver:

RF3227E 1=

RFRC-OPT 1= (1)

Program Key Port

I ∑

2000mA

Bosch Option

+12V

+12V

+12V

COM

COM

Zones

Slow flash: Normal state

On: Trouble state

Off: Trouble state

Wachdog

output

+

0 V

Zones

PO-5 +12V

L1a L1b

L2

L3

COM L4 L5 COM L6 L7 COM L8

Tamper

COM

L13

L12

COM

L11

L10

L16

COM

L15

L14

COM

L9

P0+4

P0+3

P0+

P0-2

P0-1

Y

G

B

R

GND

A C

A C

[email protected]

-

+

Battery

12V 7Ah

2

2

3

3

1

Y

G

B

R

2

Fuse 1 A

PO+4: < 750mA

PO+3: < 750mA supervised

100 Ω - 2,2 k

IUI-AMAX3 +4 Keypad

3

1

3

2

3 1

3 2

3

3

2

230V ~50Hz

230mA

1 Tamper Switch

2 Zone Switch

3 EOL 2,2 k

4 NO + NC

3

Fire

3

2

Intrusion

Figure 3.4: Wiring diagram AMAX 3000 BE / 4000

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

10

en | Connecting Modules and Devices

4 Connecting Modules and Devices

AMAX panel

The AMAX panel provides BOSCH option bus 1 and option bus 2 (only for AMAX 3000 BE and

AMAX 4000) to connect modules and devices. Each module can be connected to each bus.

A maximum of 14 modules (8 keypads) can be connected to each bus.

The following overview displays the maximum number of modules that can be connected.

Module

Keypads

DX2010

DX3010

DX4010

AMAX 2100

-

4

1

1

AMAX 3000 /

3000 BE

8

3

2

AMAX 4000

16

6

GPRS module:

B450 with B442 or B443, DX4020-

G

Up to 2 different GPRS modules, each GPRS module can only be connected once. Exception: 2 B450 modules can be connected.

IP module:

B426

RF receiver

Table 4.1: Maximum number of modules

-

2 (1 if one of the GPRS modules above is connected, 0 if two of the GPRS modules above are connected)

1

How to connect a keypad and a RADION receiver:

1.

Connect the keypad to the option bus on the AMAX panel according to the wiring diagram

(refer to Graphics).

2.

Connect the RFRC-OPT RADION receiver to the option bus on the AMAX panel according to the wiring diagram (refer to Graphics).

3.

Connect the red and black wires supplied with the battery to the AMAX panel and the battery.

4.

Connect the power adapter and battery to the mains.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

5

5.1

5.2

5.3

Programming and Operating the AMAX System | en

11

Programming and Operating the AMAX System

The AMAX system can be programmed and operated with menus by using keypads and/or the

A-Link Plus remote programming software on a PC.

When all modules and devices are installed, the AMAX panel indicates the system status with the LED status indicator on the system main board. A slow flashing in red (repeating on and off with an interval of 1 second) indicates normal system operation.

The AMAX panel begins charging the battery. The green MAINS indicator on the keypad indicates that the power supply is switched on and the keypad beeps.

4

Press any key on the keypad.

The keypad stops beeping and you are prompted to enter a code.

The AMAX system provides two types of default access codes:

Installer Code: [1234]

User Code: [2580] for master user 1 / [2581] for master user 2

Option: Changing Menu Language

If necessary, the menu language can be changed. If not, proceed to section Accessing the

Menus, page 11.

1.

Enter the installer code [1234] + [58] or the user code [2580] / [2581] + [58] and press

[#].

The available menu languages are displayed.

2.

Select the desired language on the keypad.

3.

Press [#].

P

The menu language is changed.

Accessing the Menus

Accessing the Programming Menu

1.

Confirm that the system is disarmed.

2.

Enter the installer code. The default setting for the installer code is [1234].

The system displays [958] PROGR. MODE [-EXIT].

3.

Enter [958] + press [#].

P

You have now access to the programming menu for configuring the AMAX system.

P

The STAY and AWAY indicators flash to indicate the programming mode.

Accessing the User Menu

4

Enter a user code. The default users are master user 1 (code: [2580]) and master user 2

(code: [2581]).

P

The system displays [/] USER MENU *STAY #AWAY [-] INFO.

P

You have now access to the user menu for operating the AMAX system.

Menu Navigation

This section provides an overview of how to navigate the programming menu of a text keypad.

Selecting a Menu

1.

Select the menu and operate according to the menu prompt.

2.

Press [▼] or [▲] to navigate to the desired menu.

3.

Press [#] to enter a menu.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

12

en | Programming and Operating the AMAX System AMAX panel

5.4

5.4.1

5.4.2

Exiting a Menu

4

Press [–] to get back to the previous menu.

Confirming the Input

4

Press [#] to confirm the input.

Switching between Settings

4

Press and hold [*] for 3 seconds to switch between settings.

Operating a Menu

1.

Operate according to the menu prompt.

Select the menu and enter data for specific programming items according to the display on the keypad to complete the programming, step by step.

2.

Press [#] to confirm each step.

Exiting the Programming Menu

1.

Complete all programming input by repeating the programming steps above and press [–] to get back to the current main menu level by level.

2.

Press [–] to get to the EXIT PROG. +SAVE menu.

It is optional to save or not to save the programming data.

1.

Select EXIT PROG. +SAVE and press [#] to save the data and to exit the programming mode.

2.

Select EXIT PROG. UNSAVED and press [#] to exit programming mode without saving the data.

Programming the AMAX System via Keypad

If the keypad is in standby mode, it gets enabled as soon as the first digit of a code is entered.

Setting Date and Time

After the system is powered up, date and time must be set. Otherwise, the system displays a fault.

1.

Make sure that the system is in a disarmed status (the STAY and AWAY indicators are disabled).

2.

Enter the installer code [1234] + [51] and press [*] to get to CHANGE DATE / TIME.

3.

Enter the current date and time by using the numeric keys and press [*] to confirm.

P

Date and time are set.

Deleting a Zone

The zones 1-8 are enabled by default. The zone type for zone 1 is set as 03-delay 1, for zones

2-8 as 01-instant by default. Perform the following steps if you want to delete a zone.

1.

Enter the installer code [1234] + [958] and press [#].

2.

Select 3 ZONE MANAGER and press [#].

3.

Select ADD/DELETE ZONES and press [#].

The system displays the next menu item: INPUT ZONE No.

4.

Enter the number of the zone you want to delete (example: 1) and press [#].

The system displays the next menu item: ZONE MODULE SEL.

5.

Select the correct zone module (default is 0-on board zone) and press [#].

The system displays the next menu item: ZONE FUNCTION.

6.

Enter 00 for the zone function 00-not used and press [#].

The system displays the next menu item: ZONE IN AREA. There is no need to proceed to the following menu items for deleting a zone.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

5.4.3

5.4.4

Programming and Operating the AMAX System | en

13

7.

Press [–] four times to get to the EXIT PROG. +SAVE menu.

8.

Press [#] to save the data end exit the programming mode.

P

The selected zone is deleted (example: zone 1 is deleted).

Enabling the RF Receiver for Wireless Communication

1.

Enter the installer code [1234] + [958] and press [#].

2.

Select 7 RF MANAGER and press [#].

3.

Select RF SETTING and press [#].

4.

Select RF RECEIVER and press [#].

5.

Select 1-enable and press [#].

6.

Press [#] to confirm.

7.

Press [–] three times to get to the EXIT PROG. +SAVE menu.

8.

Press [#] to save the data end exit the programming mode.

P

The RF receiver for wireless communication is enabled.

Setting up a Zone for an RF Device

1.

Enter the installer code [1234] + [958] and press [#].

2.

Select 3 ZONE MANAGER and press [#].

3.

Select ADD/DELETE ZONES and press [#].

The system displays the next menu item: INPUT ZONE No.

4.

Enter the number of the zone to which you to assign the RF device and press [#].

The system displays the next menu item: ZONE MODULE SEL.

5.

Select the correct zone module depending on the RF device:

For RFUN / RF3401E (Zone input only) select 5-RF RFUN no magn

For RFGB / RF1100E (Glass Break Detector) select 4-RF RFGB glassb.

For all other RF devices (Zone input only) select 3-RF all

6.

Press [#] to confirm.

The system displays the next menu item: ZONE FUNCTION.

7.

Enter 01 for the zone function 01-instant and press [#].

The system displays the next menu item: ZONE IN AREA.

8.

Enter the number of the area you want to assign to this zone and press [#].

The system displays the next menu item: ZONE RFID: MANUAL.

9.

Enter the RF ID manually (9 digits).

Or

Press and hold [*] for three seconds to switch to the ZONE RFID: AUTO menu.

Trigger the RF device to give alarm once.

The RF ID will be entered automatically.

10. Press [#] to confirm.

The system displays ZONE NAME INPUT [a]

11. Enter a zone name and press [#] to confirm.

The system displays again: INPUT ZONE No.

12. Press [–] four times to get to the EXIT PROG. +SAVE menu.

13. Press [#] to save the data end exit the programming mode.

P

The selected zone is set up for an RF device.

4

Test the zones after finishing programming. Trigger the zone and verify that the keypad indicates the zone as open.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

14

en | Programming and Operating the AMAX System

5.5

5.5.1

5.5.2

5.5.3

Programming the AMAX Sytem via PC and USB

AMAX panel

By using the A-Link Plus remote programming software on a PC, the AMAX panel configuration can be remotely programmed or controlled. For direct communication, the PC and the AMAX panel have to be connected with the USB cable (male A / male A).

Installing the Programming Software

4

Double-click on the A_Link_setup.exe file to install the programming software on the PC.

P

An installation wizard guides you through the installation.

Connecting the PC and the AMAX Panel

1.

Connect the USB cable to the USB port on the AMAX panel and to one of the USB ports on the PC.

2.

Follow the operating system instructions to install the USB driver.

You will find the device driver in the A-Link Plus program path for installation

(example: C:\Programme\Bosch Security System\A-Link Plus\USB_DRIVER).

3.

Open the Device Manager in the operating system control and check if the USB driver has been installed and which COM port has been assigned to it.

4.

If the USB driver has not been installed automatically, install it manually.

P

The installation creates an additional COM device on the PC.

Starting the Programming Software

1.

Select Start – All Programs – Bosch Security Systems – A-Link Plus – A-Link Plus

vn.n.n.

n.n.n = current program version

Or

Double-click the A-Link Plus vn.n.n shortcut on your computer desktop.

2.

When the Login dialog opens, enter the Operator name and Password.

The default entries are ADMIN for both the Operator and Password fields.

3.

Click OK to log in to A-Link Plus.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

5.5.4

Programming and Operating the AMAX System | en

15

Setting the COM Port

The COM port that has been assigned to the additional COM device (here COM4) has to be set in the A-Link Plus program.

4

Select File – Communication Settings from the menu bar of the A-Link Plus program.

Figure 5.1: Selecting Communication Settings

The Communication Settings dialog opens.

4

Set the COM port assigned to the additional COM device (here COM4) as Direct Link

Port.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

16

en | Programming and Operating the AMAX System AMAX panel

Figure 5.2: Communication Setting – Selecting the direct link port

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

5.5.5

Programming and Operating the AMAX System | en

17

Option: Creating a New Customer

If necessary, create a new customer.

4

Select Customer – New Customer from the menu bar.

The Customer Information index sheet opens.

Figure 5.3: Customer Information – Creating a new customer

1.

Enter the customer name in the Customer Group entry field to create a new customer.

2.

Enter other relevant customer information. The Customer Number is mandatory.

3.

Save and close.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

18

en | Programming and Operating the AMAX System

5.5.6

AMAX panel

Configuring the Control Panel

1.

Select Customer – Open Customer from the menu bar of the A-link Plus program.

The Customer Information dialog opens.

2.

Select the Control Panel Configuration index sheet.

3.

Select the Control Panel Type.

Figure 5.4: Control Panel Configuration - Selecting the control panel type

1.

Select the item Communication and Report managerReceiver setting in the same index sheet.

2.

Make sure that the value for subscriber number 1 is the same as currently programmed in

AMAX panel as receiver 1.

3.

The value is 000000, when the firmware of the AMAX panel was upgraded or when the

AMAX panel has factory settings.

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Programming and Operating the AMAX System | en

19

Figure 5.5: AMAX panel configuration – subscriber number

1.

Select the item Code manager in the same index sheet.

2.

Make sure that the value for the parameter Installer code is the same as currently programmed in the AMAX panel.

The value is 1234, when firmware of the AMAX panel was upgraded or when the AMAX panel has factory settings.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

20

en | Programming and Operating the AMAX System AMAX panel

Figure 5.6: AMAX panel configuration – installer code

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

5.5.7

Programming and Operating the AMAX System | en

21

Establishing a Direct Connection

4

Select the Link index sheet to establish a connection between the A-Link Plus program and the AMAX panel.

Figure 5.7: Link – Selecting Direct Connect

1.

Select Direct Connect as communication model.

2.

Click on the Connect button to connect to the AMAX panel.

P

If the connection is successful, the status changes to Connected and the AMAX panel type and version is displayed.

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

22

en | Programming and Operating the AMAX System

5.6

Menu Programming

AMAX panel

The following graphics show an overview of the programming menu structure displayed on a text keypad.

Menu Items Parameters / Description

1 COM+REPORT MANAG

RECEIVER SETTING

INPUT RECEIVER No.

FORMAT

1-Cid

TEL.No.(17 DIGIT)

SUBSCRIBER ID No.

2-sia dc03

TEL.No.(17 DIGIT)

SUBSCRIBER ID No.

3-conettix ip

IP/PORT 17 DIGIT

SUBSCRIBER ID No.

NETWORK ANTIREPLAY

NETW. POLLING: min

ACK WAIT TIME: sec

4-sia dc09

PROTOCOL TYPE

press *1 for *, *2 for #, *3 for P press *1 = B, *2 = C, *3 = D, *4 = E, *5 = F press *1 for *, *2 for #, *3 for P press *1 = B, *2 = C, *3 = D, *4 = E, *5 = F press *1 = B, *2 = C, *3 = D, *4 = E, *5 = F

0-disable 1-enable

05 - 99 seconds

1-Cid

2-sia dc03

IP/PORT 17 DIGIT

DC09 ID No.1(16 D)

LPREF(6 DIGIT)

DC09 RRCFR ENABLE

RRCFR(6 DIGIT)

ACK WAIT TIME: sec

5-sia dc09(2xid)

PROTOCOL TYPE

0-disable 1-enable

05 - 99 seconds

1-Cid

2-sia dc03

IP/PORT 17 DIGIT

DC09 ID No.1(16 D)

DC09 ID No.2(16 D)

LPREF(6 DIGIT)

DC09 RRCFR ENABLE

RRCFR(6 DIGIT)

ACK WAIT TIME: sec

REPORT SETTING

ZONE RESTORE REP.

AWAY ARM/DI REPORT

STAY ARM/DI REPORT

AC FAULT REP. REC.

AC FAULT REP. DOME

SYSTEM STATUS REP.

SYS REP. WITH DOME

PANIC ALARM REPORT

FIRE ALARM REPORT

MEDICAL AL. REPORT

AUTOM. TEST REPORT

0-disable 1-enable

05 - 99 seconds

0-no report

1-receiver 1

2-receiver 2

3-receiver 3

4-receiver 4

5-rec 1, 2, 3, 4

6-rec 1 (2,3,4 b)

7-rec 1,3 (2,4 b)

8-rec 1, 2

9-rec 1 (2 b)

10-rec 3, 4

11-rec 3 (4 b)

000 = No time limit 001 - 255 = 1 - 255 minutes

REPORT EXP. TIME:m

RPT DEL. ENTRY T:s

PANIC 2BUTTON AL

FIRE 2BUTTON AL

MEDICAL 2BUTTON AL

0-disabled

1-report

2-siren

3-all

Figure 5.8: Communications and Reporting Manager

Certification

EN=1

EN=1/5/6/7

EN=1/5/6/7

EN=1/5/6/7

EN=1/5/6/7

EN=0

SSI,EN=30

Default

1

000000

000000

1

1

01

1

4

000000

0

000001

05

1

000003

000003

000000

0

000001

05

6

0

6

0

0

0

0

6

6

6

6

0

30

1

1

1

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Programming and Operating the AMAX System | en

23

Menu Items

TEST REPORT DURAT.

TEST RPT INTERV: h

TEST REPORT: hour

TEST REPORT: min

DUAL IP

REMOTE ACCESS

REM. ACCESS ARMED

REMOTE PSTN ACCESS

REMOTE IP ACCESS

RPC ACCESS CODE

RPC IP/ PORT/ POLL

RPC IP ADDRESS

RPC PORT 5 DIGIT!

RPC POLL: 1-15h

CALLBACK/ DOMESTIC

CALLBACK SETTING

CALLBACK/DOMEST No

DOMESTIC CALL

DOMESTIC No (1-4)

CHANGE DOM PHO. No

CALLBACK PHONE No

RING TIMES

Parameters / Description Certification

00 = Do not use timing report 01 - 99 = 1 - 99 hours

00 - 23 hours Others = Do not use real-time report

00 - 59 minutes Others = Do not use real-time report

0-1 ip module

1-2 ip modules

EN=1-24

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0 = Panel does not answer

1 - 13 = Number of rings until the control panel responds

14 = Call the control panel and allow the phone to ring no more than twice and hang up. Wait a minimum of 8 sec and call the control panel again. The control panel answers on the first ring.

15 = Call the control panel and allow the phone to ring no more than four times and then hang up. If you call again within 45 sec, the control panel answers the call on the first ring.

Figure 5.9: Communications and Reporting Manager (continued)

Default

24

99

99

1

15

0

14

1

1

1

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

24

en | Programming and Operating the AMAX System

Menu Items

2 CODE MANAGER

USER CODE

USER No.

USER CODE PRIORITY

Parameters / Description

0-master 1 code

1-master 2 code

2-super code

3-basic code

4-arming code

5-duress code

6-not used

USER CODE IN AREA

USER MACRO AUTH.

CHANGE USER CODE

KEYFOB ID: MANUAL

KEYFOB ID: AUTO

KEYFOB BUTTON3

INSTALLER CODE

CODE LENGTH

CODE PERMISSIONS

TAMPER RESET USER

ARM/DISARM INSTAL.

MACRO CONFIG

INPUT MACRO (1-3)

LEVEL 1 ACCESS

REC T.OUT:1-80sec

PAUSE T:100ms 1-15

CODE INSIDE MACRO

Figure 5.10: Code Manager

press* 3s for AUTO. 9 Digits press* 3s for MANUAL. Trigger device, RFID will be entered

0-not used

1-output control

2-stay arm

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

AMAX panel

Certification Default

User 1=2580

User 2=2581

1

1234

4

1

1

0

60

03

1

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel

Menu Items

3 ZONE MANAGER

ADD/DELETE ZONES

INPUT ZONE No.

ZONE MODULE SEL.

ZONE FUNCTION

ZONE IN AREA

ZONE RFID: MANUAL

ZONE RFID: AUTO

ZONE NAME INPUT

ZONE FUNCTION

ZONE FUNCTION No.

ZONE TYPE

FORCE ARM/BYPASS

SILENT AL./CHIME

ZONE PULSE COUNT

ZONE LOCKOUT

Figure 5.11: Zone Manager

Programming and Operating the AMAX System | en

25

Parameters / Description Certification Default

0-on board zone

1-keypad zone

2-input mod. zone

3-RF all

4-RF RFGB glassb.

5-RF RFUN no magn

6-not used

00 = zone not used 01 - 16 = Area 1- 16 press* 3s for AUTO. 9 Digits press* 3s for MANUAL. Trigger device, RFID will be entered

00-not used

01-instant

02-interior inst.

03-delay 1

04-interior del.1

05-delay 1 exit

06-inter. del 1 e

07-delay 2

08-inter. del 2

09-delay 2 exit

10-inter. del 2 e

11-follower

12-inter. followe

13-24 hour

14-key away toggl

15-key away on/of

16-key stay toggl

17-key stay on/of

18-24 hour panic

19-24 hour fire

20-24 h fire veri

21-tamper

22-bolt contact

23-external fault

24-technical al.

25-reset

26-instant report

0-disabled

1-force arm

2-bypass

3-all

0-disabled

1-silent alarm

2-chime mode

3-all

00 = disabled 01 - 09 Pulses

0-disabled

1-1 time al. lock

2-3 time al. lock

3-6 time al. lock

EN=0/2

EN=0/2

EN=0

EN=0

00

3

0

0

0

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

26

en | Programming and Operating the AMAX System

Menu Items Parameters / Description

ZONE EOL

ZONE STATUS REPORT

UNVERF.REP/CROS.ZN

ZONE DOMESTIC CALL

0-eol 2,2k

1-deol 2,2k/2,2k

2-reserve

3-nc

4-no

0-no report

1-receiver 1

2-receiver 2

3-receiver 3

4-receiver 4

5-rec 1, 2, 3, 4

6-rec 1 (2,3,4 b)

7-rec 1,3 (2,4 b)

8-rec 1, 2

9-rec 1 (2 b)

10-rec 3, 4

11-rec 3 (4 b)

0-disabled

1-unverified alar

2-cross zone

3-all

0-no report

1-destination 1

2-destination 2

3-destination 3

4-destination 4

5-dest. 1,2,3,4

6-dest 1 /2,3,4 b

7-dest 1,3 /2,4 b

8-dest. 1,2

9-dest 1 /2 b

10-dest. 3,4

11-dest 3 /4 b

DETECT. T. x100ms

PULSE COUNT DURAT.

CROSS ZONE TIMER

000 = disabled 1 - 999 sec = Duration

Figure 5.12: Zone Manager (continued)

AMAX panel

Certification Default

1

EN=1/5/6/7 6

EN=0 0

EN=0

0

3

60

60

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Programming and Operating the AMAX System | en

27

Menu Items

4 KP/AREA MANAGER

KEYPAD AREA

INPUT KEYPAD No.

KEYPAD IN AREA

ENTRY/EXIT TIMING

INPUT AREA No.

EXIT DELAY: sec

ENTRY DELAY 1: sec

ENTRY DELAY 2: sec

COMMON AREA

Parameters / Description

01 - 16 00 = Master 99 = not used

00-none

01-follow area 2

02-follow ar 2-3

03-follow ar 2-4

04-follow ar 2-5

05-follow ar 2-6

06-follow ar 2-7

07-follow ar 2-8

08-follow ar 2-9

09-follow ar 2-10

10-follow ar 2-11

11-follow ar 2-12

12-follow ar 2-13

13-follow ar 2-14

14-follow ar 2-15

15-follow ar 2-16

KEYPAD INDICATION

KEYPAD ALARM TONE

AUDIB ENTRY ENABLE

STAY ZONE AL INDIC

BACKL. ON ENTRY T.

KEYPAD LOCKOUT

Figure 5.13: Keypad and Area Manager

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

Certification Default

EN=45

EN=10

45

30

30

0

1

0

1

1

10

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

28

en | Programming and Operating the AMAX System

Menu Items

5 SYSTEM MANAGER

SYSTEM SETTING 1

DATE/TIME

FAULT CONFIG

FAULT SOUND REMIND

AC FAULT DELAY T.

DATE / TIME FAULT

BATT. CHK INTERVAL

PHO. LN SUPERVISED

SIREN SUPERVISED

AC FAULT AUTO RST

COM FAULT AUTO RST

PHONE FLT AUTO RST

GEN FAULT AUTO RST

QUICK ARM ONLY */#

INSTALLER ACCESS

SYSTEM SETTING 2

FORCE ARM FAULT/TA

EVENT RECORD COUNT

LANGUAGE VERSION

KP 2 BUTTON ALARM

SYS TAMPER INDIC.

SYS TAMP. ALL AR.

DEOL TAMP. BYPASS

ENCL TAMP. TIMING

AREA NAME

COMPANY NAME

VOICE MEM. DEFAULT

SYSTEM VIEW

FAULT ANALYSIS

FW VERSION

FACTORY DEFAULT

FACTORY DEFAULT

DEFAULT OPTION

FACT. DEF. ENABLE

Figure 5.14: System Manager

Parameters / Description

0-disable 1-enable

0-98 min 99=disable

0-disable 1-enable

00 = disabled 01 - 15 minutes

0-disable 1-enable

0-disabled

1-po-1 enabled

2-po-2 enabled

3-po-1+2 enabled

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

3 - 10 Record count of same event per armed period

1-EN 6-PL 9-TR

2-DE 4-FR 5-PT 7NL

1-EN 3-ES 6-PL 8SE

0-disable 1-enable

0 = area1 1 = all areas

0-disable 1-enable

1 - 9999 x100ms

EN=0

EN=3-10

EN=0

EN=1

EN=15

EN=1

EN=3

EN=1

EN=1

EN=1

EN=1

EN=0

DEFAULT VOICE YES

DEFAULT VOICE NO

DEFAULT PANEL YES

DEFAULT PANEL NO

0-disable 1-enable

AMAX panel

Certification Default

1

60

0

15

0

0

1

0

0

0

0

0

1

10

1

3

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Programming and Operating the AMAX System | en

29

Parameters / Description Certification Default Menu Items

6 OUTPUT MANAGER

OUTPUT SETTINGS

ENTER OUTPUT No.

OUTPUT EVENT TYPE

OUTPUT AREA / ZONE

OUTPUT MODE

OUTPUT TIME: sec

SIREN SETTINGS

SIREN TIME: min

SIREN BEEP ENABLE

INT SIREN INDIC ON

SIREN OFF ANY KEY

Figure 5.15: Output Manager

00-not used

01-syst. disarmed

02-system armed

03-sys al audible

04-sys alarm all

05-ext.away siren

06-ext.stay siren

07-int. siren

08-int. sir w.tmp

09-entry/exit del

10-tel.line fault

11-mains fault

12-battery fault

13-tamper

14-ext. fault

15-all faults

16-fire alarm

17-fire reset

18-away armed

19-stay armed

20-reset

21-follow zn even

22-RF kf button 3

23-RF kf button 4

24-chime indic.

25-verified alarm

26-unverif. alarm

27-technic. alarm

28-bypassed zone

29-ready to arm

30-walk test

31-24 hour alarm

32-panic alarm

33-medical alarm

34-RF power fault

35-follow zone

36-schedule

00 = all/any Area/s 01–16 Area 1-16

0-continuous

1-pulse

2-continuous inv

Master Timer for Outputs

Master Timer for Outputs

0-disable 1-enable

0-disable 1-enable

0-disable 1-enable

0

000

00

1

1

1

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

30

en | Programming and Operating the AMAX System AMAX panel

Menu Items

7 RF MANAGER

RF SETTINGS

RF RECEIVER

RF SUPERVISION

RF JAM DETECT LEV.

RF LOW BATT REPEAT

SIREN BEEP ARM/DIS

RF KEYFOB PANIC AL

RF ZN MISSING = AL

RF DEVICES / USER

RF REPEATER

REPEATER No: 1-8

REPEATER ID: AUTO

KEYFOB ID: MANUAL

RF SENSOR DIAGNOSE

RF ZONE No:

RF REPEATER DIAGN.

REPEATER No: 1-8

CLR ALL RF DEVICES

Figure 5.16: RF Manager

Parameters / Description

0-disable 1-enable

0-disable

1-20min

2-1h

3-2,5h

4-4h

5-12h

6-24h

00 - 15 00 = disabled, 01 = most sensitive

0-disabled

1-4h

2-24h

0-disable 1-enable

0-no alarm

1-silent alarm

2-audible alarm

0-disable 1-enable press* 3s for AUTO. 9 Digits press* 3s for MANUAL. Trigger device, RFID will be entered

CLEAR CONFIRM

CLEAR CANCEL

Certification Default

EN=1

EN=0

0

1

12

1

1

2

1

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Programming and Operating the AMAX System | en

31

Certification Default Menu Items

8 ADDR./KEY PROGR.

ADDRESS PROGRAM

COPY DATA TO PANEL

COPY DATA TO KEY

Parameters / Description

For Addresses, refer to Installation Guide copy data from blue programming key to Panel copy data from Panel to blue programming key

Figure 5.17: Address and Key Programming

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

32

en | Technical Data AMAX panel

6 Technical Data

Electrical

Power supply type

Panel PCB maximum quiescent current in mA

Transformer

Transformer input in VAC

Transformer output in VAC

Transformer AC power in VA

Transformer fuse in mA

AC input

Minimum operating voltage in

VDC

AMAX 2100 AMAX 3000 AMAX 3000

BE

EN = A

100

230

18

20

500

195

50

1000

AMAX 4000

Maximum operating voltage in

VDC

Line voltage frequency in Hz

DC output

DC output maximum current for all components in mA

DC output maximum current for all components: dependency on battery

253

50

1100 2000

– Battery 7Ah standby 12h (recharge Batt 80% in 72h) =

550mA

– Battery 7Ah standby 36h + 15min alarm current

500mA (recharge Batt 80% in 72h) = 150mA

– Battery 18 Ah standby

12h (recharge Batt 80% in 72h) = 1500mA

– Battery 18Ah standby

36h (recharge Batt 80% in 24h) = 480mA

– Battery 18Ah standby

36h + 15min alarm current 1000mA

(recharge Batt 80% in

24h) = 400mA

Aux 1 / 2 output

Aux 1 / 2 output voltage +12V / GND

Aux 1 / 2 nominal output voltage under AC line input in VDC

13.8 (+3% / -5%)

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Technical Data | en

33

AMAX 2100 AMAX 3000 AMAX 3000

BE

Aux 1 / 2 output max. Vpp in mV 675

Aux 1 / 2 output voltage range under AC line input in VDC

12.82 – 13.9

Aux 1 / 2 output current in mA 500

13.11 – 14.2

900

Outputs

PO -1 / PO -2 maximum supervised output current in mA

500

PO -3 maximum current in mA

PO +3 / PO +4 maximum current in mA (+12V)

100

Watchdog PO -5 maximum current in mA

Option bus

Option bus nominal output voltage under AC line input in

VDC

13.8 (+3% / -5%)

Option bus output voltage range under AC line input in VDC

13.11 – 14.2

500 Option bus 1 maximum current in mA

Option bus 2 maximum current in mA

Battery

Battery type

Low battery condition in VDC

Minimum battery condition in

VDC

Electrical: Keypads

12 V / 7 Ah

Bosch D 126 below 11.0

10.8

750

100

900

900

AMAX 4000

12 V / 7Ah / 12 V / 18 Ah

Bosch IPS-BAT12V-18AH

IUI-AMAX4-TEXT

(LCD Text

Keypad)

10.8

IUI-AMAX3-LED16

(16 Zone LED

Keypad)

IUI-AMAX3-LED8

(8 Zone LED

Keypad)

Minimum operating voltage in

VDC

Maximum operating voltage in

VDC

13.8

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

34

en | Technical Data AMAX panel

IUI-AMAX4-TEXT

(LCD Text

Keypad)

31

IUI-AMAX3-LED16

(16 Zone LED

Keypad)

IUI-AMAX3-LED8

(8 Zone LED

Keypad)

Standard current consumption in mA

Maximum current consumption in mA

EN type

Mechanical

100

B

60

Dimension in cm (H x W x D)

Weight in g

Panel features

Number of zones

Number of users

Number of events

AMAX 2100 AMAX 3000 AMAX 3000

BE

26.0 x 28.0 x 8.35

1950 4700

AMAX 4000

37.5 x 32.2 x 8.8

8

64

32

128

64

250

256 history events, stamped with time, and date

256 EN history events, stamped with time, and date

256 dialer history events, stamped with time, and date

1000000 Pin code variations

Number of devices

Number of keypads

Number of DX 2010 modules

Number of DX 3010 modules

4

1

8

3

2

16

6

Number of DX 4010 modules 1

Number of GPRS modules: B450 with B442 or B443, DX4020-G

Up to 2 different GPRS modules, each GPRS module can only be connected once

Number of IP modules: B426 2 (1 if 1 of the GPRS modules above is connected, 0 if 2 of the GPRS modules above are connected)

Number of RF receivers

Number of RF repeaters

Number of RF sensors

-

-

-

1

DSRF = 0, Radion = 8

32

DSRF = 24, Radion = 128

64

Number of RF keyfobs

Zones

Zone 1 Single or dual end-of-line

(EOL 2,2KΩ)

NC, NO

2 wire fire zone, single, or dual end-of-line (EOL 2,2KΩ)

NC, NO

2015.05 | 05 | F.01U.309.297

Quick Start Manual Bosch Sicherheitssysteme GmbH

AMAX panel Technical Data | en

35

Zone 2 – 16 COM

Tamper

Option bus

Dimensions in mm

Maximum cable length in m

Maximum bus length in m

Environmental

AMAX 2100 AMAX 3000 AMAX 3000

BE

7 single or dual end-of-line (EOL 2,2KΩ)

NC, NO

AMAX 4000

15 single or dual end-ofline (EOL

2,2KΩ)

NC, NO

Enclosure tamper input (does not reduce point capacity)

4 wire, Ø 0.6 – 1.2

200 (panel to last keypad)

700 (maximum 14 devices, maximum 8 keypads)

AMAX 2100 AMAX 3000 AMAX 3000

BE

Minimum operating temperature in °C

-10

Maximum operating temperature in °C

55

Minimum relative humidity in % 10

Maximum relative humidity in % 95

Protection class IP 30, IK 06

Certification

Europe

France

Belgium

Germany

CE

EN

AFNOR

INCERT (only for AMAX 3000 BE)

VDS

AMAX 4000

EN 50130-4 (6/2011)

EN 55022 (5/2008)

EN 60950-1:2006 + A11:2009

EN 50131-3 grade 2

Environmental class II

NF a2P 1223400001

NF a2P 1223400002

Environmental class I

Home

Bosch Sicherheitssysteme GmbH Quick Start Manual 2015.05 | 05 | F.01U.309.297

Bosch Sicherheitssysteme GmbH

Robert-Bosch-Ring 5

85630 Grasbrunn

Germany

www.boschsecurity.com

© Bosch Sicherheitssysteme GmbH, 2015