MTD | 113-122A | PR13-0549_Kepner6-8_Permit_04 15 14

Cuningham Group Architecture
Contact:
Tonia Toca
Contact:
Kari-Elin Mock
Morayma Salas
Alan Doggett
601 S. Broadway, Suite N
Denver, CO
80203
1617 S. Acoma St
Denver, CO 80223
Address:
720.423.1922
(###) ###-####
TONIA_HOBAUGH-TOCA@dpsk12.org
Phone:
FAX:
E-Mail:
303 861 1600
303 861 1602
KMOCK@CUNINGHAM.COM
Mechanical, Electrical, Plumbing
Structural
Name:
ME Group
Name:
HCL Engineering & Surverying, Inc.
Contact:
Jeff Visnic
Mike Banks
Paul Plewczynski
707 17TH STREET, #3000
DENVER, CO
80202
Contact:
Chris Chen
Address:
9570 Kingston Court, Suite 310
Englewood, CO 80112
303.382.1920
(###) ###-####
JEFF.VISNIC@MEGROUP.COM
Phone:
FAX:
E-Mail:
Address:
Phone:
FAX:
E-Mail:
303.773.1605
(###) ###-####
cchen@hclengineering.com
BUILDING SECTION
NUMBER ON SHEET
DRAWING NUMBER
DRAWING TITLE
1
SIM
1
View Name
A101
1
A101
1/8" = 1'-0"
A101
SHEET ON WHICH THE
SECTION OCCURS
DRAWING SCALE
SHEET NUMBER
DETAIL
DRAWING NUMBER
WALL SECTION / DETAIL
DRAWING NUMBER
SIM
1
A101
SIM
1
A101
SHEET ON WHICH THE
SECTION OCCURS
SHEET ON WHICH THE
DETAIL OCCURS
ROOM
STRUCTURAL GRID LINE
ROOM NAME
0
101
0
ROOM NUMBER
INTERIOR PARTITION
REFERENCES PARTITION TYPE SCHEDULE
PARTITION TYPE PER SCHEDULE
A3
1
DOOR
REFERENCES DOOR SCHEDULE
PARTITION MODIFIER
DOOR NUMBER
1234
E 01 - HW
HARDWARE CODE
DOOR TYPE
FIRE LABEL
WINDOW FRAME TYPE
REFERENCES WINDOW FRAME TYPE SCHEDULE(S)
1t
LOUVER FRAME TYPE
REFERENCES COLOR AND FINISH SCHEDULE
REFERENCES LOUVER FRAME TYPE SCHEDULE(S)
HEIGHT
1t
FRAME TYPE PER SCHEDULE
FINISH
MATERIAL
FLOOR FINISH TRANSITION
REFERENCES COLOR AND FINISH SCHEDULE
EXTERIOR ELEVATION
FLR-X
SHEET ON WHICH THE
ELEVATION OCCURS
CH
CJ
CK
CL
CLR
CMU
CONC
CONT
CP
CPT
CPTB
CPTT
CT
CTB
CHALK BOARD
COLUMN COVER FINISH
CUSTOM FABRICATION
CONTRACTOR FURNISHED / OWNER
INSTALLED
CORNER GUARD
CUNINGHAM GROUP ARCHITECTURE,
INC.
CHAIR
CONTROL JOINT
CORK
CENTER LINE
CLEAR(ANCE)
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS / CONTINUE
COMPOSITE PANEL
CARPET(ED)
CARPET BASE
CARPET TILE
CERAMIC / PORCELAIN TILE
CERAMIC TILE BASE
SIM
DEC
DF
DG
DIA
DIV
DN
DRP
DWGS
DECORATIVE CONCRETE
DRINKING FOUNTAIN
DECORATIVE GLASS
DIAMETER
DIVISION
DOWN
DRAPERY/CURTAINS
DRAWINGS
(E) / EXIST
EJ
EL
ELEC
EPOX
EQ
EWC
EXP
EXT
INSUL INSULATION
INT INTERIOR
IWB INTERACTIVE WHITE BOARD
L
LIN
LMC
LWC
MAS
MAT
MATL
MAX
MB
MDF
MECH
MG
MIN
MIR
MO
MTD
MTL
FLOORING TYPES
PER SCHEDULE
COMPASS ROSE
PROJECT NORTH
N
INTERIOR ELEVATION
1
PARTBD
PL
PLAM
PLY
PME
PNL
PREFIN
PRV
PT
EXISTING
EXPANSION JOINT
ELEVATION
ELECTRIC(AL)
EPOXY PAINT
EQUAL
ELECTRICAL WATER COOLER
EXPOSED
EXTERIOR
PARTICLEBOARD
PLATE
PLASTIC LAMINATE
PLYWOOD
PATCH TO MATCH EXISTING
PANEL
PREFINISHED
POWER ROOF VENTILATOR
PAINT(ED)
QT QUARRY TILE
QTB QUARRY TILE BASE
QTY QUANTITY
FD
FE / FEC
FF / FFE
FF&E
FIN
FL / FLR
FOEW
FOS
FRP
FLOOR DRAIN
FIRE EXTINGUISHER (CABINET)
FINISH FLOOR (ELEVATION)
FIXTURES, FURNISHINGS & EQUIPMENT
FINISH
FLOOR(ING)
FACE OF EXISTING WALL
FACE OF STUD
FIBERGLASS REINFORCED WALL
PANEL
R
RAD
RB
RD
REF
REQD
RES
RESB
RFL
RO
RT
RTR
RTU
RW
GA
GALV
GB
GFRC
GFRG
GL
GMU
GAUGE
GALVANIZED
GYPSUM BOARD
GLASS FIBER REINFORCED CONCRETE
GLASS FIBER REINFORCED GYPSUM
GLASS, GLAZING
GLAZED MASONRY UNIT
S
SC
SF
SIM
SP
TRUE NORTH
2
A701
MASONRY
INSET CARPET/WALK-OFF MAT
MATERIAL
MAXIMUM
MARKER BOARD
MEDIUM DENSITY FIBERBOARD
MECHANICAL
METAL GRATE
MINIMUM
MIRROR(ED)
MASONRY OPENING
MOUNTED
METAL
OC ON CENTER(S)
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED / CONTRACTOR
INSTALLED
OF/OI OWNER FURNISHED / OWNER
INSTALLED
OFRD OVERFLOW ROOF DRAIN
OFS OVERFLOW SCUPPER
OH OVERHEAD
OPNG OPENING
OZ OUNCE
DRAWING NUMBER
4
LIGHT FIXTURE
LINOLEUM
LINEAR METAL CEILING
LINEAR WOOD CEILING
(N) NEW
NA NOT APPLICABLE
FLR-X
DRAWING NUMBER
1
A100
CB
CCF
CF
CF/OI
HOSE BIBB
HARDBOARD
HARD WOOD
HARDWARE
HOLLOW METAL
HOLLOW STEEL SECTION
T
T&G
TA
TB
TEP
TERB
TERR
TEX
TF
TFC
TOB
TOC
TOD
TOF
TOP
TOS
TOW
TPART
TT
TYP
3
3. PROVIDE MOISTURE RESISTANT (OR TILE BACKER BOARD AT WALL TILE LOCATIONS) IN LIEU
OF STANDARD GYPSUM BOARD AT RESTROOMS AND/OR CUSTODIAL AREAS.
Symbol Legend
TREAD / TABLE
TONGUE AND GROOVE
TABLE
TACKBOARD
TRANSITION EDGE PROFILE
TERRAZZO BASE
TERRAZZO
TEXTURE
TENSION FABRIC
TEXTURED FINISH CEILING
TOP OF BEAM
TOP OF CONCRETE
TOP OF DECK
TOP OF FOOTING
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TOILET PARTITION
TERRAZZO TILE
TYPICAL
VB
VCT
VIF
VIN
VNR
VP
VR
VSE
VT
VWC
VINYL BASE
VINYL COMPOSITION TILE
VERIFY IN FIELD
VINYL
VENEER
VENEER PLASTER
VAPOR RETARDER
VENEER SHELF ELEVATION
VINYL TILE
VINYL WALL COVERING
WB
WC
WD
WDB
WDV
WDW
WF
WP
WPT
WT
WWC
WHITE BOARD
WALL COVERING
WOOD
WOOD BASE
WOOD VENEER
WINDOW
WOOD FLOORING
WORK POINT
WALL PROTECTION
WINDOW TREATMENT
WOOD WALLCOVERING
A3
1
PARTITION TYPE
NA
NOT AVAILABLE
UL#
UNDERWRITERS LABORATORY (UL) FIRE RESISTANCE DESIGN NUMBER
General
● ● ●
● ● ●
● ● ●
● ● ●
MODIFIER
Modifier Legend
ACOUSTICALLY RATED PARTITION - PROVIDE SOUND ATTENUATION INSULATION
A
NON RATED, EXTEND 6" ABOVE SUSPENDED CEILING, BRACE TO STRUCTURE
ABOVE
B
NON RATED, EXTEND TO BOTTOM OF SUSPENDED CEILING ABOVE
C
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UPH UPHOLSTERY
T
THERMALLY RATED PARTITION - PROVIDE NON FACED R-XX THERMAL
INSULATION
1
1 HOUR FIRE RATED PARTITION - SEE PARTITION TYPE FOR UL FIRE
RESISTANCE DESIGN NUMBER
2
2 HOUR FIRE RATED PARTITION - SEE PARTITION TYPE FOR UL FIRE
RESISTANCE DESIGN NUMBER
3
3 HOUR FIRE RATED PARTITION - SEE PARTITION TYPE FOR UL FIRE
RESISTANCE DESIGN NUMBER
4
4 HOUR FIRE RATED PARTITION - SEE PARTITION TYPE FOR UL FIRE
RESISTANCE DESIGN NUMBER
PARTIAL HEIGHT PARTITION - SEE FLOOR PLAN FOR PARTITION HEIGHT
X' - X"
Interior Partition Types
A
1 LAYER GWB EACH SIDE
5/8" STANDARD GYPSUM WALL BOARD
STEEL STUD PER SCHEDULE
5/8" STANDARD GYPSUM WALL BOARD
PARTITION TYPE
SITE
S IRVING STR
S HAZEL COURT
2. PROVIDE FIRE RATED GYPSUM BOARD IN LIEU OF STANDARD GYPSUM BOARD AT FIRE
RATED CONDITIONS.
STUD WIDTH
ASSEMBLY WIDTH
A3
3 5/8"
4 7/8"
1
UL#: U451
A4
4"
5 1/4"
2
NA
A6
6"
7 1/4"
4
NA
Sheet Name
●
●
●
●
G001
R001
R100
R110
1
2
3
4
GENERAL INFORMATION
BASEMENT - CODE AND SCOPE PLAN
FIRST FLOOR - CODE AND SCOPE PLAN
SECOND FLOOR - CODE AND SCOPE PLAN
Architectural
● ● ● ●
● ● ● ●
● ● ● ●
○ ○ ● ●
○ ○ ● ●
A010
A190
A191
A-192
A-193
5
6
7
8
9
SITE PLAN
ENLARGED FLOOR PLANS - ADA ACCESS
ENLARGED FLOOR PLANS - SCIENCE CLASSROOMS
ENLARGED FLOOR PLANS, ROOM FINISH SCHEDULE
FIRE DAMPER LOCATIONS
Mechanical
● ● ● ●
● ● ● ●
● ● ● ●
○ ● ● ●
○ ● ● ●
○ ● ● ●
○ ○ ● ●
M001
M190
M191
M192
M193
M194
M400
10
11
12
13
14
15
16
MECHANICAL LEGEND AND NOTES
ENLARGED MECHANICAL PLANS
ENLARGED MECHANICAL SCIENCE ROOM PLANS
ENLARGED MECHANICAL SCIENCE ROOM PLANS
ENLARGED MECHANICAL PLANS - TRANSFER DUCTS
MECHANICAL ROOF DEMO AND NEW PLAN
SCHEDULES AND DETAILS
ELECTRICAL
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
○ ● ● ●
● ● ● ●
○ ○ ● ●
E001
E100
E110
E120
E121
E191
E400
17
18
19
20
21
22
23
ELECTRICAL LEGEND AND NOTES
BASEMENT PARTIAL POWER PLAN
LEVEL 1 PARTIAL POWER PLAN
LEVEL 2 PARTIAL POWER PLAN
LEVEL 2 PARTIAL POWER PLAN
ENLARGED ELECTRICAL SCIENCE ROOM PLANS
ELECTRICAL ONE LINE DIAGRAM
FIRE RESISTANCE
Property Description
XPS EXTRUDED POLYSTYRENE
RISER
RADIUS
RUBBER BASE / RESILIENT BASE
ROOF DRAIN
REFERENCE / REFER TO
REQUIRED
EPOXY RESIN FLOORING
EPOXY RESIN FLOORING BASE
RUBBER FLOOR / RESILIENT FLOORING
ROUGH OPENING
RESILIENT TILE
RESILIENT TRANSITION STRIP
ROOF TOP UNIT
REFINISHED WOOD
EXISTING SCHOOL BUILDING - ADA UPGRADES, SCIENCE CLASSROOM UPGRADES, HEAT MITIGATION, BOILER
REPLACEMENT, OTHER MINOR UPGRADES.
# NUMBER / POUND
& AND
@ AT
ADD ALTERNATES
SEATING
SEALED CONCRETE
SQUARE FOOT/FEET
SIMILAR
SPECIALTY FINISH
GOVERNING CODE:
BUILDING TYPE:
PRIMARY OCCUPANCY TYPE:
REMODELING (SF):
CONSTRUCTION MATERIALS:
PROGRAM DESCRIPTION:
ADD ALT. 2: - IN VESTIBULE 128A, CREATE A NEW STORAGE ROOM 128AA, BY
INSTALLING A NEW 1 HOUR RATED MTL. STUD PARTITION WALL, H.M. DOOR FRAME,
AND WD DOOR. PROVIDE NEW MATCHING RUBBER BASE AT NEW WALL. MODIFY LIGHT
FIXTURES SWITCH TO PROVIDE SEPARATE SWITCHING OF THE STORAGE ROOM
SEPARATE FROM THE VESTIBULE. PERFORM NECESSARY PATCH AND REPAIR WORK
OF ADJACENT SURFACES. DO NOT INCLUDE CABINET DOOR LOCKS. SEE DRAWING
3/A190 AND 5/A190 FOR WORK TO BE PERFORMED. BASE BID: DO NOT INSTALL
PARTITION WALL, DOOR, AND FRAME. PERFORM ALL OTHER WORK SHOWN ON DWGS
3/A190 AND 5/A190. INSTALL LOCKS ON ALL REMAINING CABINET DOORS.
PRIMARY DATUM
SECONDARY DATUM
100'-0"
Project Description
ADD ALT. 1: PROVIDE A NEW WASHER AND DRYER ROOM 000BA WITHIN THE (E) ROOM
000B. WORK INCLUDES NEW PARTITION WALLS, ELECTRICAL, PLUMBING, CASEWORK,
H.M. FRAME, WD. DOOR, FLOOR FINISH, RUBBER BASE, PAINTING, AND PATCH/REPAIR
OF EXISTING ADJACENT SURFACES. REFER TO DRAWINGS 2/R001, 3/R001, 2/M190, AND
3/E100 FOR WORK TO BE PERFORMED. NEW WASHER AND DRYER ARE TO BE O.F.C.I.
BASE BID: NO WORK IS TO BE PERFORMED IN THIS AREA.
100'-0"
BUILDING SYSTEM
S LOWELL BLVD
1. PARTITION TO EXTEND TO STRUCTURE ABOVE OR EQUIVALENT UNLESS NOTED
OTHERWISE.
HEIGHT/ELEVATION BENCHMARKS
SHEET ON WHICH THE
ELEVATION OCCURS
Vicinity Map
General Interior Partition Notes
SPRAY POLYURETHANE FOAM
SPECIAL PAINT
STAINLESS STEEL
SOLID SURFACE
STAIN
STAINED CONCRETE
STONE
STONE BASE
STONE VENEER
SUSPENDED
SHEET VINYL
SYSTEM
FRAME TYPE PER SCHEDULE
CEILING FINISH
10'-0"
PT-X
ACT-X
BLOCKING
BOTTOM OF
BEARING
BRICK
TABLE BASE
CG
CGA
Graphic Symbols
DRAWING TITLE
BLKG
BO
BRG
BRK
BT
HB
HDBD
HDWD
HDWR
HM
HSS
SPF
SPT
SS
SSF
ST
STC
STN
STNB
STNV
SUSP
SV
SYST
Sheet Number
Name:
GT GLASS TILE
GWT GLAZED WALL TILE
GYP GYPSUM
W FORD PLACE
W MISSISSIPPI AVE
Drawing Number
Denver Public Schools
AIR BARRIER
ACCESSORY
ACOUSTICAL CEILING PANEL
ACRYLIC
ACOUSTICAL CEILING TILE
AMERICANS WITH DISABILITIES ACT
ADHERE
ABOVE FINISHED FLOOR
ALUMINUM BASE
ALTERNATIVE / ALTERNATE
ALUMINUM
ARTWORK
ARCHITECT
ACOUSTICAL WALL TREATMENT
Construction Documents
Name:
AB
AC
ACP
ACR
ACT
ADA
ADH
AFF
ALB
ALT
ALUM
AR
ARCH
AWT
KEPNER
MIDDLE
SCHOOL
Sheet Index
Pre CD Set
Architect
Phone:
FAX:
E-Mail:
Interior Partition Types
Abbreviations
Owner
Address:
911 S. HAZEL COURT
DENVER, CO 80219
SD/DD Submittal
Contacts
W KENTUCKY AVE
Issue for Bid and Construction
Project Image
KEPNER MIDDLE SCHOOL
GENERAL RENOVATIONS
Materials
YEAR BUILT:
FIRE SPRINKLER:
2009 IBC WITH CITY AMENDMENTS
2011 NATIONAL ELECTRICAL CODE
TYPE II A
GROUP E
REFER TO SHEETS R001, R100, R110
CONCRETE, MASONRY
ADA AND CODE VERIFICATION/REVISIONS, UPDATE TO
SCIENCE CLASSROOMS
1951, 1952, 1953, 1992, 2000
NON-SPRINKLERED
Phasing Legend
EXISTING WALL
NEW WALL
DEMOLISHED WALL
EXISTING OBJECT
NEW OBJECT
DEMOLISHED OBJECT
REFERENCES BUILDING SYSTEMS TYPE SCHEDULE
XXX-X
KEYNOTE
REFERENCES SHEET KEYNOTE LEGEND
EXTENT OF SYSTEM
MATCHLINE
1
1
/ A101
1 / A101
INSULATION - BATT
BRICK
INSULATION - RIGID
CERAMIC TILE / RESILIENT TILE
PARTICLE BOARD
CONCRETE - CAST-IN-PLACE
PLASTER / GROUT
CONCRETE - PRECAST
PLYWOOD
CONCRETE BLOCK
2
8
ROUGH LUMBER /
WOOD FRAMING
EARTH
2
8
WOOD BLOCKING
1
REVISION
1
ALUMINUM
1
SH
EX = EXISTING CABINET OR HOOK
S = SURFACE MOUNTED CABINET
SH = SURFACE MOUNTED HOOK
SR = SEMI RECESSED CABINET
R = RECESSED CABINET
DATUMS - WORKPOINT AND CENTER POINT
WP
FINISHES / FURNITURE / EQUIPMENT
XX-##
TYPE PER SCHEDULE
SAND / GRANULAR FILL
WOOD - FINISHED
STONE
GLASS
STEEL / STEEL STUD FRAMING
C = CLOCK
D = SMOKE DETECTOR
E = ELECTRICAL
S = SPEAKER
T = THERMOSTAT
GRAVEL/STONE FILL
TERRAZZO
GYPSUM WALL BOARD
SEE
SCHEDULE
PTD HM FRAME
CP
FIXTURE / EQUIPMENT (ELEVATION)
C
EXISTING CONDITIONS
6"
EQ
EQ
SINGLE
DOOR
DOUBLE
DOOR
Type A
Type AA
Panel Elevations
1/4" = 1'-0"
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
EQ
EQ
Type B
Type BB
DESCRIPTION OF REVISION
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
Type C
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
EQ
1' - 0"
6"
F
A5 = 5 LB ABC EXTINGUISHER
A10 = 10 LB ABC EXTINGUISHER
EX = EXISTING EXTINGUISHER
4"
FIRE PROTECTION RATED
GLAZING OF 20 MINUTES MAX 100 SQ INCHES
2' - 1"
FIRE EXTINGUISHERS
A10
MTL FRAME - MATCH
(E) VENEER & FINISH
3' - 6"
W
SYSTEM TYPE PER
SCHEDULE
SCHOOL NO. 408
SITE NO. 091
DENVER, CO
KEPNER MIDDLE SCHOOL
1
PARENT PROJECT ID: 2216
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
GENERAL INFORMATION
KM
DESIGNED BY:
Frame Types
1/4" = 1'-0"
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
04/07/17
AS NOTED
SCALE:
Cuningham Group
Architecture, Inc.
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
G001
SHEET:
1
OF:
23
OUTSIDE TRANSFORMER
FIRE SPRINKLER
019AA
76 SF
STAIR
H
91 SF
PROJECT SCOPE
124 SF
STAIR L
ARCHITECTURAL
STOR
1.
REMODEL ONE PAIR OF CLASSROOMS (219/220) INTO SCIENCE LABRATORY.
2.
REMODEL ROOM 218 FOR USE AS A COMPUTER LAB.
3.
PROVIDE HANDRAILS AT MAIN EXTERIOR ENTRY RAMP ON THE NORTHEAST SIDE OF THE
BUILDING.
4.
PROVIDE ACCESSIBLE BENCH IN BOYS' (129B) AND GIRLS' (127B) LOCKER ROOMS.
5.
INSTALL MIRROR IN GIRL'S LOCKER ROOM (127B) TO COMPLY WITH ADA REQUIREMENTS 603.3
6.
CHANGE DOOR SWING DIRECTION AT THE NORTH SIDE OF GYM 129.
7.
PROVIDE ACCESSIBLE ENTRY AT NORTH SIDE OF GYM 127
8.
PROVIDE SAFETY UPGRADES TO SCIENCE CLASSROOMS 206, 207, 208, 209, 211, 215, & 216.
9.
REQUIRED DEMOLITION AND REPAIR WORK FOR INSTALLATION OF F.S.D. UNITS IN AIR
TRANSFER DUCTS TO SUPPORT HEAT MITIGATION EFFORTS DESCRIBED IN M.E.P. SCOPE ITEM 1
019AB
79 SF
FAN/ELEC.
019A
1100 SF
UNEXCAVATED
STOR.
MECH.
STOR.
018C
76 SF
018D
186 SF
CRAWL SPACE
020
1077 SF
MECHANICAL, ELECTRICAL, PLUMBING (REF: MEP DRAWINGS FOR SPECIFIC LOCATIONS AND WORK
TO BE COMPLETED)
1.
MECHANICAL SYSTEM IS INTENDED TO SUPPORT NIGHTTIME PURGING OF HOT AIR FROM THE
BUILDING TO MAXIMIZE COOLING. REPAIR ANY HVAC EQUIPMENT USED FOR NIGHTTIME COOLING.
SCOPE INCLUDES CALIBRATION OF ALL THERMOSTATS, AND AND CONFIRMATION OF PROPER ACTION
OF ALL CONTROL DEVICES VERIFY THAT
2.
REPAIR AND/OR PROVIDE POWERED EXHAUST FANS WHERE REQUIRED.
3.
REPLACE EXIT SIGNS AT AUDITORIUM.
4.
INSTALL EXIT SIGNS AT: MECHANICAL 002, MECHANICAL BOILER 121B, ELECTRIC ROOM 126,
ELECTRIC ROOM 256, ROOM 335.
5.
REPLACE BOILER
6.
RELOCATE WASHER/DRYER TO ROOM 000B.
UP
ELEV
STAIR G
CORRIDOR
MECH/HVAC
030
3319 SF
018
754 SF
BOILER
REPLACE BOILER.
019
1779 SF
IDF/MDG
STAIR
001
Redundant Room
C
CUST. OFF.
018B
201 SF
STO.
CORE
018A
235 SF
017
288 SF
CLASSROOM
4
R001
TOILET
STOR
018BA
35 SF
018BB
6 SF
002
785 SF
(3)
UNEXCAVATED
CLASSROOM
016
1163 SF
STO.
CLASSROOM
016A
77 SF
003
803 SF
TRANSFER AIR ZONE 2:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER DUCT
(3) AT CLASSROOM 016.
2. REFER TO MECHANICAL AND ELECTRICAL DWGS.
FOR ADDITIONAL SCOPE.
STO.
015C
164 SF
STO.
015B
81 SF
CLASSROOM
STO.
004
769 SF
015A
71 SF
LEGEND:
TRANSFER AIR ZONE 3:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER DUCT
(4) AT CLASSROOM 006.
2. REFER TO MECHANICAL AND ELECTRICAL DWGS. FOR
ADDITIONAL SCOPE.
PROVIDE (N) HOUSEKEEPING PADS, APPROXIMATE
LOCATION PER MECH. DWGS. PROVIDE EMBEDDED
STEEL CHANNEL AND STEEL PLATE ON TOP OF PAD FOR
BOILER MAINT. RE: ALSO MEP DRAWINGS FOR
INFORMATION
CLASSROOM
015
1293 SF
AREAS OF PROJECT SCOPE
CLASSROOM
005
769 SF
BOYS
000E
226 SF
CLASSROOM
(4)
CLASSROOM
STO.
014
1392 SF
014A
119 SF
006
769 SF
STO.
B-1
TOILET
OFFICE
000C
43 SF
000B
177 SF
STAIR BA
251 SF
000
5611 SF
R001
BOILER
014B
390 SF
BASEMENT - OFFICE OOOB REFLECTED CEILING PLAN
1/8" = 1'-0"
STAIR
1953 WEST WING
CLASSROOM
007
793 SF
STO.
5
2000 ADDITION
CORRIDOR
1951 EAST WING
PROVIDE ONE (N) 24"X36" ALUM.
FRAMED MIRROR. INSTALL AT
35" MAX. TO REFLECTIVE
SURFACE PER ANSI 603.3
STAIR B
019
B-2
GIRLS
B-3
ROOM 000B
REMOVE CARPET AND
RUBBER BASE FROM ROOM
TOILET
000C
B-4
000A
275 SF
TRANSFER AIR ZONE 4:
1. NO ARCHITECTURAL WORK FOR (E)
TRANSFER DUCT (6) AT CLASSROOM 012.
2. REFER TO MECHANICAL AND ELECTRICAL
DWGS. FOR ADDITIONAL SCOPE.
CORE
013
789 SF
1992 LIBRARY ADDITION
CLASSROOM
008
769 SF
PROVIDE ACCESS THROUGH
EXISTING WALL FOR
WASHER PLUMBING, DRYER
VENT, AND ELECTRICAL.
1952 SOUTH WING
KEY LEGEND
CLASSROOM
4
R001
BASEMENT LEVEL - BOILER ROOM
1/8" = 1'-0"
3
R001
012
769 SF
BASEMENT LEVEL - ROOM 000B, DEMOLITION PLAN
1/8" = 1'-0"
CLASSROOM
LAUNDRY ROOM
DOORS -SCOPE OF WORK THIS SHEET
A4
1
OFFICE
000BA
000C
43 SF
(N) RUBBER BASE AND
SEAL (E) CONCRETE
7' - 0"
000B
177 SF
+/-
7' - 2 1/2"
TOILET
009
769 SF
CARPET AND RUBBER
WALL BASE
OOBA
50 SF
ALIGN
Door 000BA at Laundry 000BA
New H.M. frame - Type 1
New Wood door - Type A
Hardware Set 106
CLASSROOM
011
755 SF
04/07/14 ISSUE FOR BID AND CONSTRUCTION
IDF/MDF
WASHER AND DRYER OF/CI
STO.
UPPER OPEN CASEWORK
000D
72 SF
NO. DATE
CLASSROOM
011A
95 SF
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
000B
177 SF
ADD ALTERNATE #1 - DWG'S 2/R001, 3/R001, 5/ROO1
R001
DENVER, CO
PARENT PROJECT ID: 2216
3
R001
2
R001
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
BASEMENT - CODE AND
KM
04/07/17
SCOPE PLAN
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
N
1
SITE NO. 091
DESIGNED BY:
TOILET
000C
43 SF
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
OFFICE
BASEMENT LEVEL - ROOM 000B NEW CONSTRUCTION
1/8" = 1'-0"
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
A
R001
DESCRIPTION OF REVISION
010
770 SF
STAIR
2
N
AS NOTED
BASEMENT - CODE AND SCOPE PLAN
Cuningham Group
Architecture, Inc.
1/16" = 1'-0"
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
R001
SHEET:
2
OF:
23
OUTDOOR STG
CUST. OUT. STG.
O/S4
158 SF
OS/3
86 SF
TRANSFER AIR ZONE 1:
1. FOR (E) TRANFER DUCT (1) ADJACENT TO ROOM
122A, INSTALL NEW F.S.D. AT FLOOR LEVEL ABOVE.
REPLACE (E) 18"X18" ACCESS PANEL IN CEILING WITH
NEW 24"X36" ACCESS PANEL.
2. REFER TO MECHANICAL AND ELECTRICAL DWGS.
FOR ADDITIONAL SCOPE AT DUCTS (1) & (2)
LOADING DOCK
STO.
140E
Not Enclosed
0/S2
22 SF
SHOP STG
STOR.
137B
131 SF
135C
278 SF
OUTSIDE STOR.
STOR
OS/1
89 SF
143D
93 SF
STAIR
PROJECT SCOPE
H
STAIR
STAIR
K
STOR.
STOR.
STOR.
140D
122 SF
137A
248 SF
KITCHEN
STOR.
135B
94 SF
136A
130 SF
METAL SHOP
135
1210 SF
STOR.
135A
58 SF
WOOD SHOP
137
1455 SF
COMPUTER LAB
SHOP OFF
136
898 SF
137C
65 SF
OFF.
CUST.
140C
127 SF
140BA
6 SF
STAFF WKRM
138
220 SF
STO.
STO.
STO.
STO.
141C
141D
142HA
142H
STO.
140
1157 SF
TOILET
STOR.
LUNCHROOM
142F
STO.
140B
45 SF
140A
8 SF
139
3529 SF
142E
STO.
CLASSROOM
141
1774 SF
139A
117 SF
G
STO.
8
A190
1
A190
129BA
61 SF
142
1023 SF
STOR.
143A
29 SF
Room
STOR.
OFFICE
CUST
120G
30 SF
145A
114 SF
145
81 SF
120H
34 SF
STO.
STO.
130C
52 SF
130C
46 SF
125A
49 SF
STOR
4
A-193
120F
74 SF
120H
36 SF
TLT
STAIR
119B
29 SF
143B
OFFICE
STAIR
STG
MUSIC
133A
73 SF
132
1169 SF
STAIR
131A
56 SF
130
309 SF
D
CLASSROOM
134
1413 SF
133
1048 SF
STO.
DN
125B
26 SF
TOILET BOYS
131B
118 SF
ART
DN
BOYS LOCKER ROOM
129B
983 SF
BOYS R.R.
129BA
211 SF
CUST.
131C
73 SF
TOILET GIRLS
131D
141 SF
RAMP DN
134A
217 SF
LOUNGE
OFF.
4
A190
129C
140 SF
124
504 SF
SPECIAL ED
CORE
BOYS
123
521 SF
122
781 SF
120A
223 SF
GIRLS LOCKER ROOM
127B
703 SF
5' - 1 1/2"
2
A190
WORKROOM
C
SPECIAL ED
GIRLS
STO.
STO.
126A
227 SF
122A
115 SF
123A
113 SF
STAIR
E
(E) 18"X18" ACCESS PANEL
IN CEILING ABOVE
OFFICE
117D
195 SF
STO.
TOILET
119A
56 SF
118A
26 SF
TLT
STO.
(2)
5
STAFF LOUNGE
118 A-193
(3)
766 SF
101E
124 SF
MAIN OFFICE
STO.
101
687 SF
101B
10 SF
128A-1
TLT
127AA
28 SF
OFF.
PTA KITCH.
127A
126 SF
128A
133 SF
GYMNASIUM
GYMNASIUM
129
3072 SF
127
3072 SF
121
5814 SF
STO.
OFFICE
121C
40 SF
121A
184 SF
STAIR
STO.
121E
121B
261 SF
101A
23 SF
OFFICE
117
183 SF
LMC/IMC
127C
139 SF
5
A190
STO.
101DA
16 SF
101C
17 SF
OFFICE
STOR.
3
A190
TLT
TLT
STO.
128A-2
129
129CA
38 SF
101D
223 SF
119
225 SF
4' - 6"
129A
199 SF
1.
MECHANICAL SYSTEM IS INTENDED TO SUPPORT NIGHTTIME PURGING OF HOT AIR FROM THE
BUILDING TO MAXIMIZE COOLING. REPAIR ANY HVAC EQUIPMENT USED FOR NIGHTTIME COOLING.
SCOPE INCLUDES CALIBRATION OF ALL THERMOSTATS, AND AND CONFIRMATION OF PROPER ACTION
OF ALL CONTROL DEVICES VERIFY THAT
2.
REPAIR AND/OR PROVIDE POWERED EXHAUST FANS WHERE REQUIRED.
3.
REPLACE EXIT SIGNS AT AUDITORIUM.
4.
INSTALL EXIT SIGNS AT: MECHANICAL 002, MECHANICAL BOILER 121B, ELECTRIC ROOM 126,
ELECTRIC ROOM 256, ROOM 335.
5.
REPLACE BOILER
6.
RELOCATE WASHER/DRYER TO ROOM 000B.
101AA
19 SF
WMNS
(1)
ELEC
CORR.
100
ELEV
142A
STO.
101DB
10 SF
STO.
142B
STO.
MECHANICAL, ELECTRICAL, PLUMBING (REF: MEP DRAWINGS FOR SPECIFIC LOCATIONS AND WORK
TO BE COMPLETED)
STO.
STO.
141A
142 SF
STO.
140CA
120 SF
143
Redundant Room
142C
STO.
STO.
144
4703 SF
STAGE
MUSIC
142D
STOR.
143E
19 SF
AUDITORIUM
142G
STO.
STAIR
L
STOR.
143C
115 SF
STO.
141B
STAIR
ART STG
1.
REMODEL ONE PAIR OF CLASSROOMS (219/220) INTO SCIENCE LABRATORY.
2.
REMODEL ROOM 218 FOR USE AS A COMPUTER LAB.
3.
PROVIDE HANDRAILS AT MAIN EXTERIOR ENTRY RAMP ON THE NORTHEAST SIDE OF THE
BUILDING.
4.
PROVIDE ACCESSIBLE BENCH IN BOYS' (129B) AND GIRLS' (127B) LOCKER ROOMS.
5.
INSTALL MIRROR IN GIRL'S LOCKER ROOM (127B) TO COMPLY WITH ADA REQUIREMENTS 603.3
6.
CHANGE DOOR SWING DIRECTION AT THE NORTH SIDE OF GYM 129.
7.
PROVIDE ACCESSIBLE ENTRY AT NORTH SIDE OF GYM 127
8.
PROVIDE SAFETY UPGRADES TO SCIENCE CLASSROOMS 206, 207, 208, 209, 211, 215, & 216.
9.
REQUIRED DEMOLITION AND REPAIR WORK FOR INSTALLATION OF F.S.D. UNITS IN AIR
TRANSFER DUCTS TO SUPPORT HEAT MITIGATION EFFORTS DESCRIBED IN M.E.P. SCOPE ITEM 1
RAMP UP
STAIR J
144A
COMP. OFFC
ARCHITECTURAL
UP
102
157 SF
OFFICE
OFFICE
COT RM
117C
154 SF
102D
81 SF
OFFICE
TOILET
117B
163 SF
102C
25 SF
101F
122 SF
COT RM
102A
98 SF
OFFICE
OFFICE
OFFICE
117A
37 SF
LMC/IMC
102B
103 SF
103
368 SF
CLASSROOM
116
769 SF
TRANSFER AIR ZONE 2:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER
DUCT (3) AT STAFF LOUNGE 118.
2. FOR (E) TRANFER DUCT (4) ON CORRIDOR SIDE OF
MAIN OFFICE 101, INSTALL NEW F.S.D. AT FLOOR
LEVEL ABOVE. USE (E) GRILLE FOR INSTALL ATION
FROM BELOW AND FUTURE MAINTENANCE ACCESS.
3. REFER TO MECHANICAL AND ELECTRICAL DWGS.
FOR ADDITIONAL SCOPE.
OFFICE
121D
221 SF
103A
126 SF
OFFICE
103B
121 SF
LEGEND:
CLASSROOM
104
769 SF
CLASSROOM
103C
126 SF
115
769 SF
STO.
OFFICE
AREAS OF PROJECT SCOPE
OFFICE
113C
28 SF
114
226 SF
CORRIDOR
100
4236 SF
CUST.
100D
34 SF
CLASSROOM
(4)
105
769 SF
COMPUTER LAB
TRANSFER AIR ZONE 3:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER
DUCT (4) AT CLASSROOM 105.
2. FOR (E) TRANFER DUCT (5) ON CORRIDOR SIDE OF
ROOM 113B, INSTALL. NEW F.S.D. AT FLOOR LEVEL
ABOVE. USE (E) GRILLE FOR INSTALL ATION FROM
BELOW AND FUTURE MAINTENANCE ACCESS.
3. REFER TO MECHANICAL AND ELECTRICAL DWGS.
FOR ADDITIONAL SCOPE.
(5)
113
1324 SF
2000 ADDITION
1953 WEST WING
1951 EAST WING
STO.
113B
55 SF
CLASSROOM
IDF/MDF
STAIR
113A
60 SF
106
793 SF
STAIR B
GIRLS
100A
263 SF
1992 LIBRARY ADDITION
CLASSROOM
112
789 SF
1952 SOUTH WING
CLASSROOM
107
769 SF
N
KEY LEGEND
CLASSROOM
111
769 SF
TRANSFER AIR ZONE 4:
NO ARCHITECTURAL WORK IN THIS AREA.
REFER TO MECHANICAL AND ELECTRICAL
DWGS. FOR SCOPE.
CLASSROOM
108
769 SF
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
CLASSROOM
STO.
DESCRIPTION OF REVISION
110
755 SF
DENVER PUBLIC SCHOOLS
DEPARTMENT OF FACILITY MANAGEMENT
CLASSROOM
110A
95 SF
109
770 SF
SCHOOL DISTRICT NO. 1
100C
72 SF
SITE NO. 091
DENVER, CO
PARENT PROJECT ID: 2216
STAIR
A
BOYS
100B
282 SF
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
FIRST FLOOR - CODE AND
KM
04/07/17
SCOPE PLAN
DESIGNED BY:
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
AS NOTED
N
R100
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
CUST.
1
AUTHORITY MADE APPR'D.
Cuningham Group
Architecture, Inc.
LEVEL 1 - CODE AND SCOPE PLAN
1/16" = 1'-0"
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
R100
SHEET:
3
OF:
23
CODE
2
R110
DEMO.
1
A191
PROJECT SCOPE
NEW
CONST.
3
A191
ARCHITECTURAL
STOR.
CLASSROOM
CLASSROOM
219
1533 SF
220
1133 SF
CLASSROOM
218
1481 SF
AUDITORIUM
BELOW
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A191
BALCONY
221
1613 SF
STAGE
BELOW
STOR.
STAFF STOR.
MENS
CUST
213D
92 SF
213H
40 SF
213E
54 SF
MECHANICAL, ELECTRICAL, PLUMBING (REF: MEP DRAWINGS FOR SPECIFIC LOCATIONS AND WORK
TO BE COMPLETED)
213C
50 SF
MODIFY (E) CLASSROOM CONFIGURATION IN
ORDER TO PROVIDE TWO NEW SCIENCE
CLASSROOMS AND PREPARATION AREA.
CUST.
1.
MECHANICAL SYSTEM IS INTENDED TO SUPPORT NIGHTTIME PURGING OF HOT AIR FROM THE
BUILDING TO MAXIMIZE COOLING. REPAIR ANY HVAC EQUIPMENT USED FOR NIGHTTIME COOLING.
SCOPE INCLUDES CALIBRATION OF ALL THERMOSTATS, AND AND CONFIRMATION OF PROPER ACTION
OF ALL CONTROL DEVICES VERIFY THAT
2.
REPAIR AND/OR PROVIDE POWERED EXHAUST FANS WHERE REQUIRED.
3.
REPLACE EXIT SIGNS AT AUDITORIUM.
4.
INSTALL EXIT SIGNS AT: MECHANICAL 002, MECHANICAL BOILER 121B, ELECTRIC ROOM 126,
ELECTRIC ROOM 256, ROOM 335.
5.
REPLACE BOILER
6.
RELOCATE WASHER/DRYER TO ROOM 000B.
213F
30 SF
218-1
218-2
219-1
219-2
220A-1
ELEV
220-2
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
ROOF
1.
REMODEL ONE PAIR OF CLASSROOMS (219/220) INTO SCIENCE LABRATORY.
2.
REMODEL ROOM 218 FOR USE AS A COMPUTER LAB.
3.
PROVIDE HANDRAILS AT MAIN EXTERIOR ENTRY RAMP ON THE NORTHEAST SIDE OF THE
BUILDING.
4.
PROVIDE ACCESSIBLE BENCH IN BOYS' (129B) AND GIRLS' (127B) LOCKER ROOMS.
5.
INSTALL MIRROR IN GIRL'S LOCKER ROOM (127B) TO COMPLY WITH ADA REQUIREMENTS 603.3
6.
CHANGE DOOR SWING DIRECTION AT THE NORTH SIDE OF GYM 129.
7.
PROVIDE ACCESSIBLE ENTRY AT NORTH SIDE OF GYM 127
8.
PROVIDE SAFETY UPGRADES TO SCIENCE CLASSROOMS 206, 207, 208, 209, 211, 215, & 216.
9.
REQUIRED DEMOLITION AND REPAIR WORK FOR INSTALLATION OF F.S.D. UNITS IN AIR
TRANSFER DUCTS TO SUPPORT HEAT MITIGATION EFFORTS DESCRIBED IN M.E.P. SCOPE ITEM 1
240B
114 SF
3
A-193
(1)
STOR.
DATA
STOR.
OFFICE
213AB
45 SF
213J
85 SF
212
117 SF
213G
65 SF
OFFICE
STAIR D
201
259 SF
STAIR C
HALL
GIRLS TOILET
217
244 SF
214
215 SF
213B
208 SF
PROVIDE 100A PANEL BOARD. SEE ELECTRICAL DWG'S. E100 AND E121.
MECH. PENTHOUSE
CLASSROOM
STOR
STOR
CLASSROOM
235
1290 SF
216
1032 SF
215A
112 SF
215B
114 SF
215
803 SF
UNIVENT
UNIVENT
OFFICE
CLASSROOM
2
A-193
WOMENS
(2)
213AA
45 SF
CLASSROOM
5
A-193
TRANSFER AIR ZONE 2:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER
DUCT (3) AT CLASSROOM 211.
2. FOR (E) TRANFER DUCT (2) ADJACENT TO
CLASSROOM 202, INSTALL NEW F.S.D. AT FLOOR
LEVEL. SEE DWG XX/A194 FOR DEMO AND
RECONSTRUCTION INFORMATION OF ADJACENT
WALLS AND CASEWORK.
3. REFER TO MECHANICAL AND ELECTRICAL DWGS.
FOR ADDITIONAL SCOPE.
202
766 SF
(3)
211
1032 SF
UNIVENT
OPEN TO
BELOW
STG
214AB
99 SF
STAIR
CLASSROOM
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
203
766 SF
E
STG
214AA
49 SF
COMP. LAB
214B
2876 SF
CLASSROOM
210
1037 SF
COMP. OFFICE
OPEN TO BELOW
214A
499 SF
OPEN TO BELOW
CLASSROOM
204
767 SF
STOR.
209A
121 SF
CORRIDOR
200
2586 SF
UNIVENT
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
FREE STANDING SINK
CLASSROOM
209
888 SF
205
767 SF
UNIVENT
CLASSROOM
TRANSFER AIR ZONE 1:
1. FOR (E) TRANFER DUCT (1) ADJACENT TO ROOM 215A,
INSTALL NEW F.S.D. AT FLOOR LEVEL . SEE DRAWING XX/A194
FOR DEMO AND RECONSTRUCTION INFORMATION OF
ADJACENT WALLS.
2. REFER TO MECHANICAL AND ELECTRICAL DWGS. FOR
ADDITIONAL SCOPE AT DUCTS (1) & (2)
LEGEND:
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
200A
211 SF
STO.
CLASSROOM
206
767 SF
200AA
16 SF
(4)
(5)
CLASSROOM
208
752 SF
UNIVENT
UNIVENT
2000 ADDITION
1953 WEST WING
CLASSROOM
207
782 SF
1951 EAST WING
STAIR B
DIA
G.
D
TRANSFER AIR ZONE 3:
1. NO ARCHITECTURAL WORK FOR (E) TRANSFER DUCT (4)
AT CLASSROOM 206.
2. FOR (E) TRANFER DUCT (5) ADJACENT TO CLASSROOM
208, INSTALL NEW F.S.D. AT FLOOR LEVEL. SEE DWG
1/A194 FOR DEMO AND RECONSTRUCTION INFORMATION
OF ADJACENT WALLS.
3. REFER TO MECHANICAL AND ELECTRICAL DWGS. FOR
ADDITIONAL SCOPE.
7
8
1
A-193
STAIR
1127 SF
SF
20 PER. 57 occ.
A191
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
SCIENCE CLASSROOM TO RECIEVE SAFETY
UPGRADES. SEE ALSO SHEET A193
UNIVENT
SCIENCE CLASSROOM
220
IST
=
1058 SF
SF
20 PER. 53 occ.
UNIVENT
50
'-0
"
SCIENCE CLASSROOM
219
AREAS OF PROJECT SCOPE
BOYS
1992 LIBRARY ADDITION
DIA
D
G.
=
IST
"
'-6
49
1952 SOUTH WING
N
KEY LEGEND
VESTIBULE
219B
59 SF
SF
PER.
SCIENCE STORAGE
219A
100 SF
SF
PER.
occ.
VESTIBULE
219C
131 SF
SF
PER.
occ.
STORAGE
220A
95 SF
SF
PER.
occ.
ROOF
88 SF
SF
PER.
occ.
25' - 0"
VESTIBULE
220C
occ.
25' - 0"
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
N
2
R110
DESCRIPTION OF REVISION
LEVEL 2 - ROOMS 218/219/220 - NEW CONSTRUCTION - CODE PLAN
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
1/8" = 1'-0"
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
SCHOOL NO. 408
SITE NO. 091
DENVER, CO
KEPNER MIDDLE SCHOOL
PARENT PROJECT ID: 2216
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
SECOND FLOOR - CODE AND
KM
04/07/17
SCOPE PLAN
DESIGNED BY:
N
1
R110
LEVEL 2 - CODE AND SCOPE PLAN
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
1/16" = 1'-0"
AS NOTED
Cuningham Group
Architecture, Inc.
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
R110
SHEET:
4
OF:
23
8' - 0"
8' - 0"
H.C.
5' - 0"
H.C.
8' - 0"
8' - 0"
H.C.
8' - 0"
(E) WALL MOUNTED ACCESSIBLE PARKING
SIGNAGE. REMOVE SIGN FROM MASONRY WALL.
PATCH SCREW HOLES WITH MATCHING CAULK.
REMOVE ANY ADHESIVE ON WALL FROM BEHIND
SIGN.
H.C.
1' - 0"
SIGN AREA = 12" x 18" MOUNT ON EXISTING POLE
REMOVE DEBRIS & ALL LOOSE CONCRETE
ON BOTH SIDES OF EXISTING JOINT ~
GRIND & SANDBLAST EXISTING JOINT SURFACE ~
FILL WITH TWO COMPONENT SELF LEVELING URETHANE SEALANT
EVENLY & RECESS 1/16" BELOW SURFACE ~
CONTRACTOR TO FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS
DO NOT OVERFILL JOINT
1' - 6"
22' - 6 1/2"
LUNCH
MGR.
5' - 0"
18' - 0"
8' - 0"
TOTAL PARKING SPACES AVAILABLE AT NORTH
AND SOUTHWEST LOTS = 78 SPACES. PER ADA
2010, TABLE 208.2 - FOUR (4) ACCESSIBLE
PARKING SPACES ARE REQUIRED. CURRENT
ACCESS AISLES DO NOT MEET REQUIRMENTS.
LOADING
9 1/2"
(E) RAMP UP
KITCHEN
LUNCHROOM
(E) POLE MOUNTED ACCESSIBLE PARKING
SIGNAGE. TO REMAIN
139
3529 SF
REMOVE (E) POLE AND SIGNAGE. SALVAGE
FOR RELOCATION.
"VAN ACCESSIBLE" SIGN
WHERE APPLIES - MOUNT
ON EXISTING POLE
6"
140
1157 SF
EXISTING CONCRETE SLAB
1/16"
9 1/2"
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
DIM
11 125/128"
(E) POLE MOUNTED ACCESSIBLE PARKING
SIGNAGE. POLE TO REMAIN. REPLACE SIGN AS
SHOWN IN DRAWING.
80" MIN. IF ADJACENT TO
ACCESSIBLE ROUTE,
OTHERWISE 60" MIN
SANDBLAST PRIOR TO SEALANT INSTALLATION ~
REMOVE ALL DEBRIS
N
4
ACCESSIBLE PARKING - EXISTING AND DEMOLTION PLAN
1/8" = 1'-0"
A010
(E) POLE MOUNTED ACCESSIBLE PARKING
SIGNAGE. POLE TO REMAIN. REMOVE SIGN
AND REPLACE WITH NEW SIGNAGE AS
SHOWN IN DRAWING 4/010
1' - 9"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
5' - 0"
8' - 0"
8' - 0"
5' - 0"
H.C.
LOADING
REMOVE SECTION OF (E)
HANDRAIL AND REPLACE WITH
ADA COMPLIANT HANDRAIL
1-1/2" Ø PAINTED
HANDRAIL - ADA
COMPLIANT
PLACE @ EXISTING
MIDDLE RAIL - FIELD
VERIFY MEASUREMENTS
FOR EXISTING HEIGHT
STRIPE FOR (N) 5'-0" WIDE
ACCESS AISLE. RE-ALIGN AND
RESTRIPE LOT TO THE EAST
FOR 8'-0" WIDE PARKING
SPACES.
H.C.
10
A010
1/2" = 1'-0"
A010
1-1/2" Ø PAINTED MTL. HANDRAIL. POST MOUNTED WITH
SLEEVE INTO (E) SLAB ON GRADE RAMP. CORE DRILL SLAB
WITH WITH A MIN. 3" DIA. DRILL BIT. GROUT HANDRAIL
SLEEVE WITH NON-METALLIC AND NON-SHRINK GROUT
(E) GUARDRAIL TO REMAIN
NEW - CONDITION @ START OF RAMP - TYP
1/2" = 1'-0"
STAINLESS STL SLEEVE
SET SCREWS
7
1-1/2" Ø PAINTED HANDRAIL
A010
1/8" WEEP HOLE
GROUT FILL SOLID TO FLUSH W/SLAB
NEW CONCRETE SLAB @ GRADE
5"
REINSTALL (E) UNISTRUT POLE. PROVIDE TELSPAR
SLEEVER CENTERED IN SPACE WITH CORE
DRILLED CONCRETE FILLED MOUNTING. INSTALL
(N) SIGNAGE AS SHOWN IN DRAWING 4/A010
11
DEMOLITION - EXISTING CONDITION @ START OF RAMP - TYP
PROVIDE (N) UNISTRUT POLE WITH TELSPAR
SLEEVE SET IN CORE DRILLED CONCRETE
FILLED MOUNTING. LOCATION SIMILAR TO
ADJACENT SPACE. INSTALL (N) SIGNAGE AS
SHOWN IN DRAWING 4/A010
139
3529 SF
1' - 0"
NEW 1-1/2" PTD STEEL PIPE
LUNCHROOM
140
1157 SF
1" = 1'-0"
1' - 0"
(E) RAMP UP
KITCHEN
CONCRETE SLAB JOINT SEALING DETAIL
(E) HANDRAIL TO REMAIN
9 1/2"
18' - 0"
H.C.
22' - 6 1/2"
H.C.
A010
(E) HANDRAIL TO REMAIN
8' - 0"
RE-STRIPE FROM EDGE OF (E)
LOADING DOCK
LUNCH
MGR.
1 1/2" = 1'-0"
6"
A010
8
ADA PARKING SIGNAGE
3' - 0"
1
1-1/2" Ø PAINTED HANDRAIL
(E) POLE MOUNTED ACCESSIBLE PARKING
SIGNAGE. POLE TO REMAIN. REMOVE SIGN AND
REPLACE WITH NEW SIGNAGE AND VAN
ACCESSIBLE SIGN AS SHOWN IN DRAWING 4/A010
RESTRIPE ACCESS AISLE TO BE 8'-0" WIDE FOR
VAN ACCESSIBILITY. RE-ALIGN AND RE-STRIPE
AISLES TO THE WEST AT 8'-0" O.C.
N
9
A010
6
ACCESSIBLE PARKING - RESTRIPING PLAN
1/8" = 1'-0"
7
NEW HANDRAIL - NORTH SECTION
A010
1/8" = 1'-0"
A010
5
NEW HANDRAIL - WEST SECTION
1/8" = 1'-0"
A010
12
NEW HANDRAIL - NORTH WEST SECTION
1/8" = 1'-0"
NEW GUARD RAIL @ GROUND CONDITION - TYP
A010
1" = 1'-0"
PROPERTY LINE
2000 ADDITION
2
A010
1953 WEST WING
+/-
1
A010
40'-1"
9
A010
1951 EAST WING
(E) CONCRETE RAMP
(E) HAND RAIL. REPAINT TO MATCH (E)
T.O. (E) RAMP
NEW PTD. MTL. HAND RAIL
7
(E) STAIRS
"
18' - 9 1/2
5' - 0"
1992 LIBRARY ADDITION
UP
19' - 5"
5' - 0 3/4"
42' - 2"
UP
6
A010
+/-
UP
STAIR
(E) WALL
K
10
11
5
UP
1952 SOUTH WING
REPAIR (E) CONCRETE JOINT
SEE DRAWING 8/A010
A010
A010
N
KEY LEGEND
12
A010
NEW PTD. MTL. HAND RAIL
REPAIR CONCRETE @ B.O. RAMP
1' - 0"
UP
AUDITORIUM
144
4' - 0"
7' - 8 1/2"
END OF (E) HANDRAIL EXTENSION IS
TOO SHORT AND DOES NOT CHANGE TO
MATCH LEVEL GRADE. MODIFY
EXTENSION TO MEET ADA
REQUIREMENTS. SEE PICTURE 2 FOR
CURRENT CONDITION.
PROPERTY LINE
(E) WALKWAY
A010
(E) WALKWAY
END OF (E) HANDRAIL EXTENSION IS
TOO SHORT AND DOES NOT CHANGE
TO MATCH LEVEL GRADE. MODIFY
EXTENSION TO MEET ADA
REQUIREMENTS.
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
DESCRIPTION OF REVISION
DENVER PUBLIC SCHOOLS
DEPARTMENT OF FACILITY MANAGEMENT
10' - 1 1/2"
SCHOOL DISTRICT NO. 1
CORR.
100
3
A010
SITE PLAN - AERIAL IMAGE
NTS
A010
(E) RAMP PLAN
SITE NO. 091
DENVER, CO
PARENT PROJECT ID: 2216
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
SITE PLAN
KM
DESIGNED BY:
N
2
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
(E) ACCESSIBILITY RAMP
(E) HAND RAIL. PAINT TO
MATCH NEW
N
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
04/07/17
AS NOTED
SCALE:
1/8" = 1'-0"
Cuningham Group
Architecture, Inc.
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
A010
SHEET:
5
OF:
23
4' - 0"
MIN.2 WHEELCHAIR
1/2" MAX
CLEARANCE
CLR.
2' - 6"
(E) LOCKERS TO REMAIN
1' - 10"
7
A190
REMOVE TWO (E) MIRRORS (ONE
AT 22" H X 34" W, ONE AT 34" H X
46" W. SALVAGE FOR
RELOCATION.
REMOVE (E) CONCRETE
BENCH.
3.
PAINTING OF ALL SURFACES: All rooms and areas where work is being performed is to painted
to match existing adjacent surface U.N.O. on these drawings.
6' - 7 1/2"
4.
NOTIFICATION REGARDING EXISTING ELEMENTS: The contractor shall be responsible to verify
demolition and new construction is free and clear of existing building elements such as wall switches, fire
alarms, sensors, outlets, grilles, ducts, and other related existing elements. The contractor shall notify the
architect of any conflicts prior to proceeding with demolition and await a coordinated response from the
architect and owner before continuing with work.
MIN.
17"-19"
REINSTALL (E) MIRRORS AT 35" MAX.
A.F.F. PER ANSI 603.3 FOR LOCATIONS
NOT ABOVE A LAVATORY.
A190
LEVEL 2
5.
DEMOLITION AND SALVAGE OF ELEMENTS: The contractor shall verify with the architect the
building elements that are to be salvaged for reuse prior to the beginning of demolition. Certain items such
as doors, door hardware, toilets, and toilet fixtures should be assumed for salvage reuse.
8' - 4"
GIRLS
GIRLS LOCKER ROOM
126A
227 SF
127B
703 SF
PATCH MOUNTING HOLES IN
CONCRETE FLR FROM REMOVED
LOCKERS AND BENCH. PATCH
HOLES IN GLAZED CERAMIC BLOCK
WALL FROM TRIM BOARD
GIRLS LOCKER
ROOM
127B
REMOVE TRIM BOARD
BEHIND (E) BENCH.
ACCESSIBLE BENCH.
6
PROVIDE FINISHED END PANEL @ (E)
METAL LOCKERS TO MATCH EXISTING
FINISH
1/4" = 1'-0"
1' - 6"
4' - 0"
(E) CONCRETE FLOOR TO REMAIN
TYP. ADA BENCH - PARTIAL PLAN
CLEAR FLOOR SPACE
FOR WHEELCHAIR
3' - 2 3/4"
INSPECT GLAZED CERAMIC BLOCK
BEHIND REMOVED LOCKERS AND
CONSULT WITH ARCHITECT ON
REPAIR OR PATCH WITH MATCHING
OR ACCENT BLOCK IF REQUIRED.
(E) FRAMED OPENING TO REMAIN
4' - 1 1/2"
REMOVE TWO BANKS OF
(E) LOCKERS AND BASE BELOW.
2.
EXISTING HVAC FITTINGS: All existing HVAC ceiling fittings designated for reuse shall be cleaned
prior to reinstallation.
2" MAX
A190
1.
REPAIR OF EXISTING ELEMENTS AND FINISHES: Patch and repair all existing holes,
discontinuities, damage, cracks, discolorations, and dislocations of existing surfaces and finishes
discovered in the course of the construction, where those elements contribute directly to the quality and
performance of the finished alterations. Particular attention shall be given to the repair of existing elements
to be left visible as part of the finished alterations.
TYP. ADA BENCH
1' - 5"
3' - 6"
SEE PICTURE #01
7
GENERAL SHEET NOTES:
(20"-24")
6.
NEW INFILL WALLS: All new infill walls to be constructed of 3-5/8" metal stud w/ gypsum board
ea. side, U.N.O. Finishes shall match adjacent surfaces, typ.
DOORS -SCOPE OF WORK THIS SHEET
N
1
A190
Door 129 at Gym 129
New H.M. frame - Type 1A
New H.M. door - Type AA
Hardware Set 102
N
8
LEVEL 1 - ROOM 127B - GIRLS LOCKER ROOM - DEMOLITION PLAN
1/8" = 1'-0"
A190
6
LEVEL 1 - ROOM 127B - GIRLS LOCKER ROOM - NEW PLAN
1/8" = 1'-0"
A190
TYP ADA BENCH - SECTION
1" = 1'-0"
Door 128A:
New H.M. frame - Type 1
New Wood door - Type A
Hardware Set 104
STO.
218DD
61 SF
SF
PER.
occ.
Door 128A-1 at Gym 127:
Existing H.M. frame
New Wood door - Type A
Hardware Set 103
ONE MASONRY COURSE
ALL THE WAY AROUND
7
A190
SAW CUT
OPENING WIDTH
OR GREATER
FRAMED
R.O.
SAW CUT
OPENING
BOYS LOCKER ROOM
(E) WD BENCHES TO
REMAIN
8" MASONRY
C5X9
C7X12.2
7' - 0"
N
4
LEVEL 1 - ROOM 129B - BOYS LOCKER ROOM - DEMOLITION PLAN
1/8" = 1'-0"
A190
9' - 11 3/4"
9
LEVEL 1 - ROOM 129B - BOYS LOCKER ROOM - NEW PLAN
1/8" = 1'-0"
A190
STORAGE
128AA
ADD ALT. #2 - PROVIDE NEW ROOM ID TAG
AND PLAQUE AT DOOR. SEE DOOR LABEL
STANDARDS ON DWG A191
REMOVE (E) COUNTERTOP, BASE AND
UPPER CABINETS, AND REFRIGERATOR
ALONG WEST WALL ONLY. SALVAGE FOR
OWNER REUSE
DETAIL PROVIDED BY HCL ENGINEERING
MASONRY LINTEL DETAIL
NTS
ADD ALT. #2 - NEW WD DOOR AND HM FRAME
70 SF
SF
PER.
DETAIL B
ADD ALT. #2 - NEW STUD FRAMED PARTITION WALL
occ.
PROVIDE LOCKS ON BASE AND UPPER CABINET DOORS
ADD ALT. #2 - NO LOCKS REQUIRED.
NEW LINTEL ABOVE PER 9/A190.
STL CHANNEL AT JAMB OPNG, FILLED W/
GROUT.
MASONRY BLOCK
2000 ADDITION
1953 WEST WING
PLASTER
(E) RAMP
GROUT SOLID
STO.
129A
199 SF
1' - 0"
10
A190
STOR.
129A
BOYS GYM
129
1' - 10"
REMOVE (E) WD. DOORS AND HM FRAME
GIRLS GYM
127
129
128A
128A-2
A4
1
1951 EAST WING
STEEL LINTEL. SEE
DWG 9/A190
STOR.
HM FRAME
127C
139 SF
7' - 1 1/4"
STOR.
127C
4' - 0"
KITCH.
128A
3' - 0"
SEALANT
UP
3' - 3"
6" MASONRY
NOTE:
UNLESS NOTED OR SHOWN OTHERWISE, PROVIDE
LINTEL FRAME SHOWN ABOVE IN NON-BEARING
WALLS. PROVIDE SOLID GROUT AROUND FRAME IN
JAMBS, SILL & HEAD. HORIZONTAL MASONRY
CHAMBERS SHALL BE SEALED TO KEEP GROUT
FROM OVERFLOWING INTO OTHER AREAS
N
11
A190
HM HEAD AT MASONRY OPENING
1" = 1'-0"
BOY'S LOCKER 129B
GIRL'S LOCKER 127B
128A-1
GYM 127/129 ENTRY
VESTIBULE
11
A190
NEW WD DOORS AND HM FRAME
(E) 3'-0" WD DOOR AND HM FRAME TO
REMAIN
128A
59 SF
GYMNASIUM
GYMNASIUM
129
3072 SF
127
3072 SF
LOCATION FOR FUTURE
REFRIGERATOR BY OWNER
GROUT SOLID
HM FRAME
1992 LIBRARY ADDITION
SEALANT
1952 SOUTH WING
MASONRY BLOCK
SEE PICTURE #03. REMOVE SECTION OF (E)
CMU WALL BACK TO FACE OF COLUMN.
MASONRY TO BE CUT CLEANLY TO ENABLE
INSTALLATION OF NEW JAMB.
RELOCATE (E) WALL SWITCH IN KITCHEN
A190
NON-BEARING WALL LINTEL FRAME
0 THRU 4'-0"
129B
983 SF
5' - 7 1/4"
3
DETAIL A
129BA
211 SF
OPENING WIDTH
REMOVE (E) 2'-8" WD. DOOR AND
HM. FRAME
STEEL LINTEL FRAME
ALL AROUND OPENING
~ SEE BELOW FOR
CORNER WELDING
BOYS R.R.
(E) CONCRETE FLOOR TO
REMAIN
STOR.
129A
GROUT TWO
COURSE
UNDER JAMB
REFINISH END OF (E) BENCH
TO MATCH
130
309 SF
FRAMED R.O.
1/2" MAX GAP
TO BE FILLED
W/ MORTAR
SAW CUT
OPENING
LOUNGE
(E) LOCKERS TO REMAIN
A190
Opening128A-2 at Vestibule 128A:
New H.M. frame at masonry opening
B
(E) MOUNTING BRACKET FOR
BENCH TO REMAIN
2
SOLID GROUT ~
SEE ADJ. ELEVATION
FOR EXTENT
ACCESSIBLE BENCH
5' - 6"
2' - 1" 4' - 1 1/4"
TOP OF WALL
ADJ
ADJ
REMOVE SEGMENT OF (E)
WOOD BENCH AND
RELATED SUPPORT
BRACKETS.
4' - 0"
+/-
6' - 0"
EXTENT OF SOLID GROUTING
PATCH MOUNTING HOLES IN CONCRETE
FLR FROM REMOVED WOOD BENCH
SUPPORT
REMOVE (E) CONCRETE
BENCH. SEE PICTURE # 02
BOYS LOCKER ROOM
129B
A
CLEAR FLOOR SPACE FOR
WHEELCHAIR.
N
N
5
LEVEL 1 - GYM 127 & 129 - ENTRY DOORS - DEMOLITION PLAN
1/8" = 1'-0"
KEY LEGEND - FIRST FLOOR
N
A190
10
LEVEL 1 - GYM 127 & 129 - ENTRY DOORS - NEW PLAN
1/8" = 1'-0"
GLAZED CERAMIC BLOCK
A190
HM JAMB AT MASONRY OPENING
1" = 1'-0"
WD DOOR AND HM FRAME
TO BE REMOVED
GLAZED CERAMIC BLOCK
LOCKERS TO BE REMOVED
04/07/14 ISSUE FOR BID AND CONSTRUCTION
TYP. BASE BELOW LOCKERS
TO BE REMOVED UNDER
IDENTIFIED LOCKERS.
CONCRETE BENCH TO
BE REMOVED
NO. DATE
128A
WIDEN OPENING BY CUTTING
OUT WALL SEGMENT
DEPARTMENT OF FACILITY MANAGEMENT
TRIM BOARD TO BE REMOVED
SITE NO. 091
DENVER, CO
PARENT PROJECT ID: 2216
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
ENLARGED FLOOR PLANS KM
04/07/17
ADA ACCESS
DESIGNED BY:
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
TYP. MOUNTING AND BRACKET
ASSEMBLY TO BE REMOVED
PICTURE #02 - BOY'S LOCKER ROOM 129B - EXISTING CONDITIONS
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
END OF WOOD BENCH
SEGMENT TO BE REMOVED
CONCRETE FLOOR
PICTURE #01 - GIRL'S LOCKER ROOM 127B - EXISTING CONDITIONS
SCHOOL DISTRICT NO. 1
(E) DOOR TO BE
MODIFIED FOR BOYS'
GYM
CONCRETE FLOOR
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
(E) ADA RAMP
CONCRETE BENCH TO BE REMOVED
DESCRIPTION OF REVISION
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
AS NOTED
Cuningham Group
Architecture, Inc.
PICTURE #03 - (E) DOOR TO ROOM 128A TO BE MODIFIED AS NEW ENTRY TO
GIRLS GYM 127
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
A190
SHEET:
6
OF:
23
(E)UNIVENT
Door 219-1 at Science Lab.#219
New H.M. frame - Type 1
New 20 min. Wood door - Type B
Hardware Set 107
Provide Hazmat sign as shown
Door 220B-2 at Science Prep. #220B
New H.M. frame - - Type 1
New 20 min. Wood door - Type B
Hardware Set 105
Provide Hazmat sign as shown
Door 219-2 at Science Lab.#219
New H.M. frame - - Type 1
New 20 min. Wood door - Type B
Hardware Set 107
Provide Hazmat sign as shown
Door 220-1 at Science Lab.#220
New H.M. frame - Type 1
New 20 min. Wood door - Type A
New Hardware 107
Provide Hazmat sign as shown
Door 219A-1 at Science Storage #219A
New H.M. frame - Type 1
New Wood door - Type A
Hardware Set 104
Provide Hazmat sign as shown
Door 220-2 at Science Lab.#220
New H.M. frame - Type 1
New 20 min. Wood door - Type A
Hardware Set 108
Provide Hazmat sign as shown
TYP. POWER AND DATA POLES TO BE REMOVED
REMOVE (E) SINK AND
COUNTER
REMOVE CHALKBOARD. LOCATION OF
FUTURE SINKS ALONG WALL
(E) UNIVENTS AND
COUNTERS TO
BETWEEN ARE TO
REMAIN U.N.O.
(E)UNIVENT
UNIVENTS AND CASEWORK ON NORTH WALL TO
REMAIN - TYP.
(E)UNIVENT
CARPET TO BE REMOVED. ANY (E) VCT BELOW TO BE REMOVED
LOCATION OF POSSIBLE (E) PLUMBING
PICTURE # 01 - PROPOSED SCIENCE CLASSROOM 219 - TYP. EXISTING CONDITIONS
REMOVE (E) COUNTER
(E) ADHERED CEILING TILE AND (E) LIGHT FIXT. TO BE REMOVED
POSSIBLE FLOOR OUTLETS 4
(E) INTERACTIVE
WHITEBOARD TO REMAIN
A191
3.
Interactive Whiteboards, Screens and Computers: Coordinate with the District's
Department of Technical Services (DoTS) for removal and salvage of this equipment for future
reuse. Remove all tack boards, chalk boards, whiteboard, clocks, from walls prior to demolition.
Verify with District whether items are to be salvaged or replaced.
Existing interactive white board at (E) Science #220 to be relocated to new Science #220 south wall
REMOVE DOOR AND FRAME TO CREATE NEW
VESTIBULE
DPS DOOR LABEL STANDARDS - SIGNAGE @ NEW DOORS
REMOVE (E) VCT FLOOR. INSTALL (N) VCT FLOOR
WITH RUBBER BASE
PICTURE # 02 - SCIENCE CLASSROOM 220 - TYP. EXISTING CONDITIONS
(E) COLUMN
DENVER PUBLIC SCHOOL DOOR LABEL STANDARDS
TYPE A: 1/8" thick photopolymer sign panels with 1/32" raised copy and symbols with Grade II
braille. Mounted to wall with VHB double-sided tape and silicone adhesive. Used for
Storage rooms, Prep rooms, exc.
4"
SIGN TYPE C
REMOVE (E) CASEWORK
###
TYPE B: Photopolymer sign panels with 1/32" raised copy and symbols with Grade II braille. 2
clear
insert windows. Mounted to wall with VHB double-sided tape and silicone adhesive. Only
used outside of classrooms.
SIGN TYPE C
7"
SEE PICTURE #02
RECESSED LOCKERS
1
(E) INTERACTIVE
BOARD TO BE RELOCATED
AT SCIENCE 220 SOUTH WALL
SIGN TYPE A/B
6"
RECESSED LOCKERS
23' - 3 1/2"
EXISTING CARPET
AND WALL BASE
TO BE REMOVED
7"
1 1/2"
(E)UNIVENT
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
SEE PICTURE #01
2.
Repair of existing elements and finishes: Patch and repair all existing holes, discontinuities,
damage, cracks, discolorations, and dislocations of existing surfaces and finishes discovered in the
course of the construction, where those elements contribute directly to the quality and performance
of the finished alterations. Particular attention shall be given to the repair of existing elements to be
left visible as part of the finished alterations.
CLOSET AND DOOR TO REMAIN FOR ACCESS
INTO NEW STORAGE ROOM FROM CORRIDOR.
9"
53'-
REMOVE (E) TACKBOARD
(E) CHALKBOARD TO REMAIN
REMOVE (E) FIRE BLANKET CANISTER
REMOVE (E) FIRE EXTINGUISHER
REMOVE ALL ACCESSORIES ALONG SOUTH WALL
NET AREA = 1066 SF
OCC. = 54
REMOVE (E) RECESSED
CASEWORK
(E) COLUMN
REMOVE ALL ACCESSORIES ALONG EAST WALL.
(E) COLUMN
e=
tanc
Dis
nal
(E) COLUMN TO
REMAIN
"
7'-8
=5
CLASSROOM 219
NET AREA = 1512 SF
OCC. = 76
nce
ista
al D
gon
AREA OF CONCRETE SLAB TO
BE REMOVED FOR SHOWER/
EYEWASH FLOOR DRAIN. NEW
CONCRETE TO SLOPE TO
DRAIN. REF: MEP DWGS.
go
Dia
Dia
(E) FREE STANDING CASEWORK
TO BE RELOCATED BY OWNER
CMU WALLS WITH
FURRED METAL LATH
& PLASTER
TO BE DEMOLISHED,
TYP
1.
Notifications regarding existing elements: The contractor shall be responsible to verify
demolition and new construction is free and clear of existing building elements such as wall
switches, fire alarms, sensors, outlets, grilles, ducts, and other related existing elements. The
contractor shall notify the architect of any conflicts prior to proceeding with demolition and await a
coordinated response from the architect and owner before continuing with work
Door 220B-1 at Science Prep. #220B
New H.M. frame - - Type 1
New 20 min. Wood door - Type B
Hardware Set 105
Provide Hazmat sign as shown
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
TYPE C: 2 ply dual color modified acrylic panels. Mounted to wall with VHB double-sided tape and
silicone adhesive.
###
SIGN TYPE B
CASEWORK GENERAL NOTES
7"
N
HAZARDOUS
MATERIALS SIGN
AT SCIENCE
CLASSROOM AND
PREP ROOMS
4' - 0"
(E) COLUMN
(E) CHALKBOARD TO REMAIN
WEST WALL AND CASEWORK TO BE REMOVED
EXISTING FLOOR
ABATED PRIOR
TO CONSTRUCTION
PREPARE FLOOR
TO RECEIVE NEW
FLOORING
GENERAL SHEET NOTES - SCIENCE AND COMPUTER CLASSROOMS:
1" 1"
(E)UNIVENT
LIMITED CLEARANCE AT WINDOW HEAD. TYP. 219 AND 220
REMOVE (E) CASEWORK
SCIENCE CLASSROOM
218
DOORS -SCOPE OF WORK THIS SHEET
1"
(E)UNIVENT
(E) ADHERED CEILING TILE AND (E) LIGHT FIXT. TO BE REMOVED
1 1/2"
(E)UNIVENT
(E) UNIVENTS AND
COUNTERS TO
BETWEEN ARE TO
REMAIN U.N.O.
Level 2 - Rooms 218/219/220 - DEMOLITION PLAN
1/8" = 1'-0"
7"
1 1/2"
SALVAGE (E) POWER/DATA POLES (TYP 6)
FOR OWNER. COIL (E) DATA CABLES AND
PROTECT DURING CONSTRUCTION FOR
STG. ABOVE NEW CLG.
1.
2.
3.
4.
###
Casework to be compliant with AWI custom grade standards U.N.O.
Provide PVC edgeband on counters, back & side splashes, doors, and drawer fronts.
Counters to be plastic laminate U.N.O.
Base and upper cabinets to be plastic laminate, flush overlay construction.
SIGN TYPE A
4' - 9 3/8"
26' - 7 1/2"
7' - 2 1/4" 7 1/4"
SCIENCE CLASSROOM
219
1058 SF
SF
20 PER. 53 occ.
(E) UNIVENT
(E) UNIVENT
###
SCIENCE CLASSROOM
220
(E) UNIVENT
(E) UNIVENT
A191
(E) UNIVENT
(E) UNIVENT
13
13
CASEWORK DESIGN SERIES (CDS) NUMBER
11
1127 SF
SF
20 PER. 57 occ.
2' - 0"
ACID RESISTANT
SINKS
GWB
GWB
A191
A191
A4
B
A4
B
(E) EXTERIOR WALL
(E) SUSPENDED PLASTER CEILING
H.M. WINDOW
A.C.T.
34' - 10"
10'-6"
A.F.F.
7 125/128"
T.B.
MIN
220B-1
TEACHING WALL
W.B.
W.B.
219-1
A4
1
A4
1
219A-1
9
12
2' - 0"
10'- 6" A.F.F.
(N) ACT SYSTEM
(N) BULKHEAD - GWB AND MTL STUD
(E) WINDOW
T.B.
7
220B-2
10
GWB
32' - 4"
11
CEILING AT SCIENCE CLASSROOM
1/4" = 1'-0"
FIRE EXTINGUISHER AND
BLANKET CABINET
A4
B
219-2
A4
1
GWB
A191
24' - 9 1/2"
REF.
EYE WASH AND SHOWER. SEE DWG.
6/A192 FOR DETAIL AT DRAIN.
(N) FINISH LAYER OF GWB
A.C.T.
34' - 11"
10'-6"
A.F.F.
FUME HOOD
5 1/4"
5' - 1 1/4"
PATCH AND REPAIR WALL AREA
WHERE ELEMENTS HAVE BEEN
REMOVED. REPAINT ENTIRE
WALL TO MATCH.
T.B.
PLAM APRON
T.B.
FIRE EXTINGUISHER AND
BLANKET CABINET
A191
A4
B
DW
H.M. WINDOW
FIRE EXTINGUISHER AND
BLANKET CABINET
A191
8
5
EYE WASH AND SHOWER.
SEE DWG 6/192 FOR DETAIL
AT DRAIN.
(E) UNIVENT
ALIGN BACKSPLASH WITH
ADJACENT (E) BACKSPLASH.
ACID RESISTANT COUNTERTOP
A191
(E) COL.
7' - 4"
GOGGLE CABINET - O.F.C.I.
A4
B
4
6
218
1' - 1"
FUME HOOD
SCIENCE CLASSROOM
220-1
A4
1
STORAGE
220A
A4
1
95 SF
SF
PER.
A4
1
occ.
2000 ADDITION
A4
1
TEACHING WALL
W.B.
W.B.
ROOMS 218, 219, & 220
220-2
GWB
GWB
32' -A.F.F.
4"
8'-0"
A4
1
32'
8'-0"- 4"A.F.F.
GWB
GWB
1951 EAST WING
32' - 4"
8'-0"
A.F.F.
- 4"
8'-0"32'A.F.F.
32' - 4"
8'-0"
A.F.F.
GWB
11"
MIN
NON-CORRODING ACID CABINET 36"X36"X18", FULL HT.
SHELVING
RUBBER BASE TO MATCH (E)
SCIENCE STORAGE
219A
SCIENCE PREP
220B
100 SF
281 SF
SF
PER.
FLAME RESISTANT STOR. CABINET W/ FLAME ARRESTOR
36"X36"X24". O.F.C.I.
13
A191
3
Custom Sink Detail
1" = 1'-0"
SF
PER.
occ.
EYE WASH AND SHOWER. SEE DWG.
6/A192 FOR DETAIL AT DRAIN
SEE ELECTRICAL DRAWING 2/E191 FOR FIXTURE IDENTIFICATION & LOCATION
GOGGLE CABINET - O.F.C.I.
occ.
N
N
2
LEVEL 2- ROOMS 219/220 - NEW CONSTRUCTION
A191
1/8" = 1'-0"
LEVEL 2 - ROOM 218/219/220 REFLECTED CEILING PLAN
A191
TACKBOARD -24"X42" (TYP. 2)
(E) COLUMN
TACKBOARD 24"X42" (TYP. 2)
EYEWASH/SHOWER
FUME HOOD
324
(E) UNIVENT AND CASEWORK PROVIDE
INFILL TO MATCH NEW BASE CABINETS
310
T.B.
102
102
W.B.
101
RUBBER BASE
LOCKING CABINETS @ ALL LOCATIONS EXCEPT FOR
UNDER SINK
CHEMICAL RESISTANT
COUNTERTOP
4
A191
1/8" = 1'-0"
324
310
310
324
324
CHEMICAL RESISTANT COUNTERTOP
310
RUBBER BASE
101
1' - 6"
153
102
102
101
2' - 6"2' - 6"2' - 6"
A191
LEVEL 2 - ROOM 219 - SOUTH TEACHING WALL
1/8" = 1'-0"
6
A191
153
2' - 6"
1' - 6"
5
LEVEL 2 - ROOM 219 - EAST ELEVATION
324
4" BACKSPLASH
ALL CABINETS TO BE
LOCKABLE, EXCEPT
UNDER-SINK
CABINETS, TYP
3' - 0"
SEE 13/A191
W.B.
1992 LIBRARY ADDITION
1952 SOUTH WING
OPEN UPPER SHELF
310
SHOWER/EYEWASH
302
2' - 10"
4" BACKSPLASH
LOCKING CABINETS @
ALL LOCATIONS EXCEPT
FOR UNDER SINK
HM WINDOW
LOCKING CABINETS @ ALL LOCATIONS
EXCEPT FOR UNDER SINK
WALL CABINET WITH
LOCKING GLASS DOORS
AND ADJ. SHELVES.
S.S SINK WITH
ACCESSIBLE REMOVABLE PANEL
1' - 6"
101
101
153
102
102
2' - 6"2' - 6"2' - 6"
1' - 6"
1' - 6"
101
153
101
3' - 0"
CHEMICAL RESISTANT SINK WITH
ACCESSIBLE REMOVABLE PANEL
1953 WEST WING
1/8" = 1'-0"
310
PAPER TOWEL AND SOAP
DISPENSER. TYP. FOR
EACH SINK
324
310
310
324
324
310
N
KEY LEGEND - SECOND FLOOR
153
101
102
102
153
101
101
153
102
102
101
153
101
4" BACKSPLASH
2' - 6"
1' - 0"
324
2' - 6"
INFILL PANEL AT ENDS
MATCH BASE CABINET FINISH
9
LEVEL 2 - ROOM 219 - WEST ELEVATION
1/8" = 1'-0"
A191
2' - 6"2' - 6"2' - 6"
2' - 6"2' - 6"2' - 6"
2' - 6"
1' - 6"
1' - 6"
1' - 6"
1' - 6"
1' - 6"
LEVEL 2 - ROOM 220 - EAST ELEVATION
1/8" = 1'-0"
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
H.M. WINDOW
BASE CABINETS WITH
LOCKING DOORS
101
1' - 0"
102
102
SEE 13/A191
2' - 6"2' - 6"2' - 6"
1' - 0"
W.B.
W.B.
101
RUBBER BASE
INFILL PANEL AT ENDS
MATCH BASE CABINET FINISH
312
102
102
1' - 6"
102
102
102
2' - 6"2' - 6"2' - 6"2' - 6"
101
FUME HOOD
W/ ACID CABINET
RUBBER BASE
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
(E) COLUMN
REFRIGERATOR
OF/CI
DISHWASHER
OWNER OF/CI
ALL CABINETS TO
BE LOCKABLE,
EXCEPT
UNDER-SINK
CABINETS, TYP
102
2' - 0"
2' - 0"
SEE 13/A191
2' - 6"
A191
LEVEL 2 ROOM 220 - WEST ELEVATION
1/8" = 1'-0"
10
A191
LEVEL 2 - ROOM 220 SOUTH TEACHING WALL
1/8" = 1'-0"
7
A191
SCIENCE PRE. EAST ELEVATION
1/8" = 1'-0"
8
A191
SITE NO. 091
DENVER, CO
PARENT PROJECT ID: 2216
1' - 0"
2' - 0"
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
ENLARGED FLOOR PLANS KM
04/07/17
SCIENCE CLASSROOMS
DESIGNED BY:
CHEMICAL RESISTAMT
COUNTER & SINK WITH
ACCESSIBLE REMOVABLE
PANEL
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
RUBBER BASE
12
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
101
102
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
FUME HOOD
3' - 0"
302
2' - 10"
4" BACKSPLASH
CHEMICAL
RESISTANT
COUNTERTOP.
COORDINATE
WITH DPS
LOCATION AND
NUMBER
OF GROMMETS
IN COUNTER
312
4" BACKSPLASH
ALL CABINETS TO BE LOCKABLE,
EXCEPT UNDER-SINK
CABINETS, TYP
4' - 0"
CHEMICAL RESISTANT COUNTERTOP
3' - 0"
SHOWER/EYE
WASH
324
4' - 0"
T.B.
310
3' - 0"
5' - 0"
GOGGLE CABINET
5' - 0"
H.M. WINDOW
S.S. SINK WITH
ACCESSIBLE REMOVABLE PANEL
3' - 6"
RECESSED FIRE
EXTINGUISHER AND
BLANKET CABINET
4" BACKSPLASH
WALL CABINETS WITH
ADJUSTABLE SHELVES
3' - 0"
HM WINDOW
ALL CABINETS TO BE LOCKABLE, EXCEPT
UNDER-SINK
CABINETS, TYP
FUME HOOD
(E) COLUMN W/ (N) 1 5/8" MTL STUD AND 5/8"
GWB.
2' - 10"
EYEWASH/SHOWER
DESCRIPTION OF REVISION
AS NOTED
Cuningham Group
Architecture, Inc.
SCIENCE PREP. WEST ELEVATION
1/8" = 1'-0"
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
A191
SHEET:
7
OF:
23
Room Finish Schedule
Num.
Name
Level
Floor
Finish
Base
Finish
North
Walls
East South
West
Ceiling
Material Finish
Height
Remarks
ADDITIONAL BASE SCOPE SAFETY UPGRADES:
PT-1
PT-1
PT-1
PT-1
ACT
ACT
-
LEVEL 1
127B GIRLS LOCKER ROOM
LEVEL 1
(E)
(E)
(E)
(E)
PT-1
(E)
(E)
(E)
128A VESTIBULE
129B BOYS LOCKER ROOM
LEVEL 1
LEVEL 1
VCT
(E)
RB
(E)
PT-1
(E)
PT-1
PT-1
PT-1
(E)
PT-1
(E)
GWB
(E)
PT-1
(E)
219A SCIENCE STORAGE
219B VESTIBULE
219C VESTIBULE
220 SCIENCE CLASSROOM
220A STORAGE
220B SCIENCE PREP
220C VESTIBULE
RB
PT-1
PT-1
PT-1
PT-1
(E)
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
LEVEL 2 - CODE AND
SCOPE PLAN
GOGGLE CABINET - O.F.C.I.
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET
PAINT ONLY THE WALL WHERE BENCH HAS BEEN
REPLACED
PT-1
(E)
(E)
(E)
PT-1
PT-1
(E)
(E)
(E)
VCT
RB
PT-1
PT-1
PT-1
PT-1
ACT
-
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
VCT
RB
PT-1
PT-1
PT-1
PT-1
ACT
-
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
VCT
RB
PT-1
PT-1
PT-1
PT-1
GWB
PT-1
8' - 0"
FINISH FLOOR
10' - 6"
5
A-192
NET AREA = 963 SF
OCC. = 48
TYP INTERIOR ELEVATION - SAFETY UPGRADES SCIENCE CLASSROOM 208
1/4" = 1'-0"
EYE WASH & SHOWER
MICROSCOPE (30)CABINET
FIRST AID KIT
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
X - ITEMS TO BE PROVIDED AND INSTALLED BY CONTRACTOR
O - ITEMS THAT ARE O.F.C.I.
(E) SINKS, COUNTER AND
BASE CABINETS
10' - 6"
(E) CASEWORK AND UNIVENTS
CLASSROOM
UNIVENT
219 SCIENCE CLASSROOM
VCT
PAINT ONLY THE WALL WHERE BENCH HAS BEEN
REPLACED
UPGRADE
FIRE BLANKET + CABINET
SPILL CONTROL KIT
GOGGLES+CABINET
CHEM. RESIT. APRONS
SHOWER/EYE WASH + DRAIN
GFI OUTLETS
MSTR. ELEC. SWITCH
ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM ROOM
206
207
208
209
211
215
216
218
219
220
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O
O
211
1032 SF
(E) SINKS, COUNTER
AND BASE CABINETS
4
A-192
(E)FREE STANDING SINK
LEVEL 2 - SAFETY UPGRADES - SCIENCE CLASSROOM 211
1/8" = 1'-0"
GOGGLE CABINET - O.F.C.I.
UNIVENT
LEVEL 2 - CODE AND SCOPE PLAN
218 SCIENCE CLASSROOM
LEVEL 2
NEW SURFACE MOUNTED FIRE
EXTINGUISHER AND BLANKET CABINET
NEW GOGGLE CABINET
4' - 0"
LEVEL 2
128AA STORAGE
8' - 6"
RECESSED CASEWORK
(E)
PT-1
(E) SINKS, COUNTER
AND BASE CABINETS
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET
GOGGLE CABINET - O.F.C.I.
(E) CASEWORK AND UNIVENTS
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET
CLASSROOM
209
888 SF
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
CLASSROOM
206
767 SF
EYE WASH & SHOWER
EYE WASH & SHOWER
(E) CASEWORK AND UNIVENTS
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
(E) SINKS, COUNTER
AND BASE CABINETS
(E) SINKS, COUNTER
AND BASE CABINETS
GOGGLE CABINET - O.F.C.I.
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET
CLASSROOM
CLASSROOM
208
752 SF
207
782 SF
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET
UNIVENT
(E)
PT-1
NET AREA = 709 SF
OCC. = 36
GOGGLE CABINET - O.F.C.I.
(E) CASEWORK AND UNIVENTS
A-192
(E) SINKS, COUNTER
AND BASE CABINETS
STRAINER CLAMPING DEVICE
STRAINER
ADJUSTABLE DRAIN HEAD
CLAMPING COLLAR
MEMBRANE FLASHING
FLANGE
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
SLOPE TOPPING SLAB TO DRAIN
(E) PRECAST 2 WAY
CONCRETE DECK
VCT WITH SEALANT AT DRAIN PERIMETER
EYE WASH & SHOWER
UNIVENT
RB
RB
UNIVENT
CPT
VCT
UNIVENT
BASEMENT LEVEL
BASEMENT LEVEL
UNIVENT
BASEMENT LEVEL
000B OFFICE
OOBA LAUNDRY ROOM
(E) CASEWORK AND UNIVENTS
(E) CONCRETE JOIST
EQ
5
(E) SINKS, COUNTER
AND BASE CABINETS
EQ
VARIES
CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF DRAIN IS CENTERED BETWEEN
CONCRETE JOISTS & CLEAR OF OBSTRUCTIONS BELOW. CONTACT ARCHITECT TO VERIFY
LOCATION AND IF DRAIN IS IN CONFLICT WITH STRUCTURE OR OTHER BUILDING ELEMENTS
BEFORE PROCEEDING WITH WORK.
2
A-192
1
LEVEL 2 - SAFETY UPGRADES SCIENCE CLASSROOM 208 & 209
1/8" = 1'-0"
A-192
6
LEVEL 2 - SAFETY UPGRADES - SCIENCE CLASSROOM 206 & 207
1/8" = 1'-0"
A-192
FLOOR DRAIN DETAIL FOR EYEWASH/SHOWER & SCIENCE PREP.
1" = 1'-0"
AREA OF CONCRETE SLAB TO BE
REMOVED FOR SHOWER/ EYEWASH
FLOOR DRAIN. NEW CONCRETE TO
SLOPE TO DRAIN. REF: MEP DWGS.
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET.
GOGGLE CABINET - O.F.C.I.
(E) TEACHING PLATFORM,
COUNTER, & SINK
CLASSROOM
216
1032 SF
(E) SINKS, COUNTER
AND BASE CABINETS
EYE WASH & SHOWER
6
A-192
EYE WASH & SHOWER
SURFACE MOUNTED FIRE
EXTINGUISHER AND
BLANKET CABINET.
04/07/14 ISSUE FOR BID AND CONSTRUCTION
NO. DATE
DESCRIPTION OF REVISION
DENVER PUBLIC SCHOOLS
(E) TEACHING PLATFORM,
COUNTER, & SINK
CLASSROOM
215
803 SF
AUTHORITY MADE APPR'D.
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
(E) SINKS, COUNTER
AND BASE CABINETS
SCHOOL NO. 408
SITE NO. 091
DENVER, CO
KEPNER MIDDLE SCHOOL
GOGGLE CABINET - O.F.C.I.
PARENT PROJECT ID: 2216
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
ENLARGED FLOOR PLANS,
KM
04/07/17
ROOM FINISH SCHEDULE
DESIGNED BY:
AREA OF CONCRETE SLAB TO BE REMOVED FOR SHOWER/
EYEWASH FLOOR DRAIN. NEW CONCRETE TO SLOPE TO
DRAIN. REF: MEP DWGS.
3
A-192
(E) CASEWORK AND UNIVENTS
ALONG SOUTH WALL
(E) CASEWORK AND
UNIVENTS ALONG
SOUTH WALL
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
AS NOTED
Cuningham Group
Architecture, Inc.
LEVEL 2 - SAFETY UPGRADES SCIENCE CLASSROOM 215 & 216
1/8" = 1'-0"
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
A-192
SHEET:
8
OF:
23
(E) GLAZED CERAMIC BLOCK
(E) COLUMN
(E) LOCKERS BELOW DUCT
(E) TRANSFER DUCT (1)
CLASSROOM
216
REMOVE A MINIMUM OF 2'-0"H X 2'-6"W
SEGMENT OF (E) PLASTER AND MASONRY
WALL FOR INSTALLATION OF DAMPER AT
FLOOR LEVEL. PATCH AND REPAIR WALL
TO MATCH ADJ.MATERIALS AND FINISH.
CLASSROOM
215
STORAGE
215A
FIRESAFING TO BE INSTALLED BETWEEN (E)
DUCT AND (E) EXPOSED CONDENSER LINES
THROUGH PENETRATION IN FLOOR.
(E) EXPOSED CONDENSER LINES TO BE
PROTECTED IN PLACE.
3
PICTURE 02 - INSIDE STORAGE 215A
SHOWING WALL FOR DEMOLITION
1/4" = 1'-0"
(E) INTAKE GRILLE
(E) TRANSFER DUCT (1) ABOVE CEILING
(E) EXHAUST GRILLE TO REMAIN
CLASSROOM
123
STORAGE
122A
CLASSROOM
122
(E) 18"X18" ACCESS PANEL
(E) ROOF ASSEMBLY
(E) DUCT OPNG INTO PLENUM
4
A-193
LEVEL 1 - F.S.D. CEILING PLAN AT STOR. 122A - TRANSFER ZONE 1, DUCT 1
1/4" = 1'-0"
(E) SUSPENDED CEILING
(E) GRILLE
(E) TRANSFER DUCT (2)
REMOVE 2'-0"H X 4'-0" PORTION OF (E)
GLAZED CERAMIC BLOCK BEHIND
CASEWORK FOR INSTALLATION OF
DAMPER AT FLOOR LEVEL. PATCH AND
REPAIR WALL TO MATCH WITH SIMILAR
MATERIALS AND FINISH.
(E) LOCKERS
(E) GLAZED CERAMIC BLOCK
ROOM
PORTION OF (E) WALL TO
BE REMOVED FOR
DAMPER INSTALLATION
AND REPLACED TO
MATCH (E)
CORRIDOR
V.I.F.
REMOVE, SALVAGE, AND REINSTALL
(E) CASEWORK. REPAIR AFFECTED
PORTIONS AS NEEDED TO MATCH
ADJACENT (E) CASEWORK
2' - 0"
8' - 0" VIF
(E) LOCKERS
4'-0" VIF
PICTURE 03 - INSIDE STORAGE 122A
SHOWING (E) ACCESS PANEL & GRILLE
(E) PLASTER OVER MASONRY, TYP.
(E) CERAMIC BLOCK
WAINSCOT, TYP.
26' - 8"
LEVEL
2
(E) WALL BASE
(E) SUSPENDED CEILING
NEW FIRE/SMOKE DAMPER,
RE: SHEET M193;
TO BE INSTALLED IN (E) OPNG AND
ATTACHED TO (E) DUCTS PER MFR
INSTRUCTIONS
(E) GLAZED CERAMIC BLOCK
ACCESS TO DAMPER AND DUCT
THROUGH (E) GRILLE
(E) COLUMN
CORRIDOR
200
PICTURE 04 - CLASSROOM 202. SHOWING
CASEWORK AND GLAZED TILE
2
A-193
CLASSROOM
202
ROOM
5
LEVEL 2 - F.S.D. AT CLASSROOM 202 - TRANSER ZONE 2, DUCT 2
1/4" = 1'-0"
A-193
CORRIDOR
(E) CONCRETE SLAB
13' - 4"
LEVEL
1
TYP. WALL SECTION AT TRANSFER ZONE AT LEVELS 1 - 2
1/4" = 1'-0"
(E) COLUMN
(E) CLOSET
CLASSROOM
208
REMOVE 2'-0"H X 4'-0" PORTION OF
EXISTING GLAZED CERAMIC BRICK AND
MASONRY UNIT BEHIND. FOR
INSTALLATION OF DAMPER AT FLOOR
LEVEL. PATCH AND REPAIR WALL TO
MATCH WITH SIMILAR MATERIALS AND
FINISH.
CORRIDOR
200
04/07/14 ISSUE FOR BID AND CONSTRUCTION
(E) TRANSFER DUCT (5)
NO. DATE
DESCRIPTION OF REVISION
DEPARTMENT OF FACILITY MANAGEMENT
SCHOOL DISTRICT NO. 1
(E) GLAZED CERAMIC BLOCK
A-193
DENVER, CO
911 S. HAZEL CT. DENVER, CO 80219
MS
AD
FIRE DAMPER LOCATIONS
KM
DESIGNED BY:
DENVER PUBLIC SCHOOLS
DEPARTMENT OF
FACILITY MANAGEMENT
LEVEL 2 - F.S.D PLAN AT CLASSROOM 208 - TRANSFER ZONE 3, DUCT 5
SITE NO. 091
PARENT PROJECT ID: 2216
(E) GLAZED CERAMIC BLOCK
1
SCHOOL NO. 408
KEPNER MIDDLE SCHOOL
(E) COLUMN
PICTURE 05 - CLASSROOM 208. SHOWING
GLAZED TILE
AUTHORITY MADE APPR'D.
DENVER PUBLIC SCHOOLS
4'-0" VIF
PICTURE 01 - VIEW DOWN TRANSFER
DUCT 1 IN ZONE 1
A-193
LEVEL 2 - F.S.D. PLAN AT STOR 215A - TRANSFER ZONE 1, DUCT 1
APPROVED CONTRACT DOCUMENT
DRAWN BY:
CHECKED BY:
DATE:
04/07/17
AS NOTED
SCALE:
1/4" = 1'-0"
Cuningham Group
Architecture, Inc.
®
DATE:
www.cuningham.com
Copyright
©
601 S. Broadway, Suite N
Denver, CO 80209
Tel: 303 861 1600
Fax: 303 861 1602
2014 by Cuningham Group Architecture, Inc. (All Rights Reserved)
DWG NO.
A-193
SHEET:
9
OF:
23