Mettler Toledo LJ16 User manual

Operating instructions METTLER TOLEDO LC-P45 Printer 11 ID .01.200 0 71-015:28:3 0.6 3 3 316206.55 -34 4 5 g Su 45.7.92 g ----- m 3 ----- 3420 2.54 g g END .74 ----- g ---2 1 7 Def 8 Men u 4 ID Cod 1 45 P r 1 2 3 2 Res rinte 6 e F LC-P 9 5 ult 3 31 Men u 0 Clea r METTLE R TOLE DO Overview 1 2 3 4 5 6 7 8 Introduction Startup procedure Applications Operation Printer functions Maintenance Malfunctions Appendix 1.1 2.1 2.2 2.3 4.1 4.2 4.3 4.4 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.1 6.2 7.1 7.2 8.1 8.2 8.3 8.4 What are the capabilities of the LC-P45 Printer → Page 3 Cautionary notes → Page 4 Inserting the batteries and paper, attachment, printing → Page 5 Setting date and time → Page 6 Selecting applications → Page 7 Using the keypad → Page 10 Configuring the printer in the menu → Page 10 Entering values of variables (e.g. lot identification ID) → Page 12 Selecting printer function → Page 13 Printing out weight values → Page15 Generating statistics of a weight series → Page16 Totalizing weight values → Page 17 Multiplying (dividing) the weight by a factor → Page 18 Recording the moisture determination with the LP16/LJ16 IR Dryer → Page 19 Pipette test for calibrating volumetric dosing apparatus → Page 19 Recording the processes with M-Pac application software packages → Page 21 Checking a balance with a test weight → Page 22 Calibrating (adjusting) a balance with a calibration weight → Page 23 Changing paper and ribbon → Page 24 Maintenance, Service and Cleaning → Page 25 Interpreting the error messages → Page 26 Printer test → Page 28 Accessories for GA45 Printer (paper, ribbon, etc.) → Page 28 I/O interfaces → Page 29 Attachment to METTLER TOLEDO instruments, additional hardware, available functions → Page 30 Technical data → Page 33 1 Introduction 1.1 What are the capabilities of the LC-P45 Printer? The LC-P45 is a versatile dot matrix printer with advanced print functions for normal paper. It can supplement the weight value with date, time and other data. It has two LocalCAN interfaces and one RS-232-C interface and is primarily suitable for attachment to METTLER TOLEDO balances and scales equipped with the standard software, but will also print out the records of the METTLER TOLEDO application software Pacs (M-Pacs) and of the LP16 and LJ16 METTLER TOLEDO Infrared Dryers. The various print functions of the LC-P45 can be selected in the dialog mode (English, German, French, Spanish or Italian). The settings are stored in a failsafe manner thanks to battery buffering. • Print weight The LC-P45 prints out the weight displayed on the balance directly. - Date and time - Lot identification (ID) - Balance identification - Current sample No. For users complying with quality management regulations such as GLP or GMP or for those who wish for a detailed record of a weighing. You can supplement the weighing result by automatically printing out any of the adjacent data. - Sample code The sample code, a comment for a more detailed definition of the weighing sample, is entered directly for every sample. • Totalization Without the need to purchase peripherals or software, the LC-P45 automatically generates statistics of the weight values of your sample series and calculates the most important statistical parameters. Pa ge s 7/ 8 g .0 68 34 1 ID 1.0 1 .2 8 00 0 • Generate statistics 7. 4. 14: 5- 53 22 :3 .0 2 3 • Insertion of The LC-P45 can also totalize weight values, thus calculating and documenting running totals. This function is especially useful when weighing in formulations. • Multiplication/division This function allows weight values to be multiplied or divided by any desired factors, Typical examples are calculating prices based on a price per unit weight or converting weights into volumes. • Check balance and calibrate A check on the accuracy of a balance by means of a test weight is fully documented. Likewise, adjustment of the balance by means of a calibration weight. • LP16/LJ16 Infrared Dryer Date, time and lot identification (ID) are automatically added to the record. • Pipette check This function enables pipettes and other volumetric measuring and dosing apparatus to be calibrated by a simple method which is also completely documented. 2 Startup procedure 2.1 Cautionary notes For reasons of safety, the housing of the printer must not be opened by the user. If technical faults appear or if the printing unit or power line fuse has to be changed, please notify your responsible METTLER TOLEDO service. • The LC-P45 Printer may be used only indoors and on no account in hazardous areas. • The electronics of the LC-P45 Printer are protected against the ingress of splashing water and dust. However, as the printer housing is not tight the printer should not be used in the presence of liquids. • Comply with cleaning instructions (see page 25), protect power plug against wet conditions. • Never open the printer housing. Should you ever have problems with your printer, please contact your responsible METTLER TOLEDO dealer. 2.2 Inserting the batteries Two batteries are provided and supply the clock and the memories for the variable settings of the printer when it is not connected to the power supply. Please note: To avoid loss of any printer settings you may have made, attach the LC-P45 Printer to the power supply when changing the batteries. • Lift up paper cover and pull paper backward out of the printing unit • Open battery compartment and insert batteries 7 Def 8 Men 4 5 Code 1 F MET TLER 6 u Clea r 3 lt 5 Pr 0 Men 12 3 2 Resu GA4 9 u ID inte r 31 Inserting paper • Feed paper through the slot in the printing unit in the direction of the arrow • Switch on printer (toggle switch at right rear, the number of the software version will be printed out automatically) • Press and hold until sufficient paper has been fed in 7 Def 8 Men 4 5 Code F MET TLER lt P45 6 12 3 2 Resu LC- 9 u ID 1 Prin ter 0 Men u Clea r 3 31 Attaching printer, printing • Plug the cable supplied into the LC-P45 and the I/O data interface of a balance or instrument. The printer is now ready for operation! • Balance Print out the weight value of the balance If no printout appears: Set both devices to the factory setting! (The interface parameters are then matched. Green pilot lamp flashes, see page 26; available functions, see page 30) 8 Menu 0 Menu set the LC-P45 to the factory setting 2.3 Setting date and time Setting or changing date and time to local time. Date (EURO or US version) 7 Def 1 • Start date definition 31 4 .... The input process can be checked in the balance display Correction of wrong entry Clear 3 • Entry of the date, e.g. • Concluding definition 23.01.97 (EURO format, day.month.year) or 1-23-97 (US format, month-day-year) Please note: Separation of the numbers with EURO by ".", with US by "-" Time (24-hour format) 7 3 • Start time definition Def 1 3 .... 5 • Entry of the current time, e.g. 13.46.05 (hours.minutes.seconds) • Concluding definition 3 Note: prints out date and time directly at all times 3 Selecting applications Printing out weight values Page 15 (1 ... record header → p. 11) 5 3468.08 g ID 04-83-18.5 3468.08 g 2 Lot identification (ID) + weight 11.01.2000 ID 04-93-18.5 3468.08 g 3 Date + lot identification + weight 11.01.2000 14:53:32 ID 04-93-18.5 3468.08 g 4 11.01.2000 14:53:32 ID 04-83-18.5 STANDARD V10.50.00 TYPE : PM6100 INR : 911375 3468.08 g 5 Complete documentation following GLP (Good Laboratory Practice) 14 15 16 17 0.49 55.61 64.03 123.97 Page 16 11.01.2000 14:25:33 ID 52-88.6.31 1 99.5 g 2 101.5 g 3 103.5 g 4 100.5 g 5 102.4 g 6 104.5 g n 6 _ x 101.98 g s 1.87 g srel 1.83 % min. 99.5 g max. 104.5 g dif. 5.0 g --------- END -------- 1 Print out weight by itself Date + time + lot identification + weight Generating statistics of weight values 11.01.2000 14:53:32 3468.08 g 4 4 Date + time + weight (ID set to 0) g g g g Current sample number + weight Totalization Page 17 11.01.2000 15:28:33 ID 71-00.6-34 206.55 g 1 2 3165.92 g 3 45.73 g 4 2.54 g Sum 3420.74 g --------- END -------- • Simple formula weighing Multiplying (dividing) Factor * Page 18 3.5 2.51 g 8.80 • Calculating prices 1500.08 g Code 8806-4.29 Weight + sample code (comment on weighing) • Determine production homogeneity • Determining volume • Demonstrate reproducibility of an experiment • Weighing in any weight units • Determining density • Calculating weight of area or length (kg/m2 or g/m) LP16/LJ16 IR Dryer Page 19 11.01.2000 15:28:33 71-00.6-34 ID Time 5.0 Min Temp 160 C Mode Timer 0..-100% 0.0M 11.010 g 1.0M -0.20 % 2.0M -1.36 % 3.0M -2.53 % 4.0M -3.18 % 5.0M -3.41 % Time eff. 5.0 Min -3.41 % -0.377 g --------- END -------- • Documentation of a drying operation Pipette check Page 19 11.01.2000 11:15:50 ID 1128489 SNR: 1118000002 Factor 1.0032 Rounding 0.0001 0.09844g 1 98.7550µl 0.09870g 2 99.0158µl 0.09876g 3 99.0760µl 0.09882g 4 99.1362µl n 4 x 98.99575µl s 0.16786µl _ srel 0.17% min. 98.7550µl max. 99.1362µl dif. 0.3812µl --------- END -------• Verification of volumetric dosing apparatus (pipettes, volumetric flasks, burettes, etc.) • Generating statistics and calculating the most important statistical parameters METTLER M-Pacs application software Page 21 ---------------------- % FORMULA ---------------------- 11.01.2000 13:29 *Target: 2500.00 g ******* 1*Comp 20.00 % 19.91 % Weight Weight 497.84 g 2*Comp 7.50 % Weight 7.56 % Weight 188.94 g Total 686.80 g Total 27.47 % ---------------------- 2501.10 g Total Total 100.04 % ---------------------- • Documentation of the process sequence, e.g. of a formula weighing operation Checking balance with test weight * Page 22 Calibrating Page 23 (adjusting) balance with calibration weight * ---- BALANCE TEST ---- 11.01.2000 14:31:57 -BALANCE CALIBRATION - 11.01.2000 16:51:57 METTLER TOLEDO Balance Type: PG503DR-S SNR: 1113000000 METTLER TOLEDO Balance Type: PG503DR-S SNR: 1113000000 Int. calibration done Target: 200.000 Actual: 200.005 Diff: 0.005 Internal test done Signature: ...................... --------- END -------- Signature: ...................... --------- END -------- • Documentation of the check following GLP and ISO 9001 • Documentation of the calibration following GLP and ISO 9001 * The printed records of the functions “Checking” and “Adjusting” appear in the respective national language only on connection to PR/SR balances. With all other balance models, English is used as the standard language. 10 4 Operation 4.1 7 Def 8 9 Menu 0 Menu 4 5 6 ID Code 1 2 3 1 2 3 F Result Clear Using the keypad Purpose of the keypad 1. Configuring the printer 2. Entry of variable values, e.g. lot identification (ID) 3. Selection of the printer function Input mode The printer functions are set in the dialog mode. The entries appear in the balance display and the LC-P45 prints them out as confirmation. 31 4.2 Configuring the printer in the menu What is set and how? The menu is used to configure the operational setting of the LC-P45: • Set LC-P45 to factory setting • Activate checking and calibration of the balance • Select record header • Select language of the dialog and record texts • Select interface parameters 8 Menu ... 9 ... 0 Menu These three keys are used to enter the menu, choose the setting and store the selected setting. Note: Variables are inputted directly. It is not necessary to enter the menu. 8 --------- Menu ------ ACTIVATE: Factory setting Verification Calibration RECORD HEADER: * No record header 1 2 ID 3 Date/ID 4 Date/Time/ID 5 Date/Time/ID/Bal. LANGUAGE/SPRACHE: * English Deutsch 9 Français 1) Español Italiano 1) BAUDRATE: 2) * 2400 0 1200 2) Menu PARITY: * even/7 bit odd/7 bit Clear no/7 bit no/8 bit HANDSHAKE: 2) * off xon/xoff hardware Menu 8 Menu 8 Menu Configuring the printer 8 Entry into menu Menu 8 Jump to next menu item, e.g. RECORD HEADER, LANGUAGE/SPRACHE... Menu 9 Selection of the setting within a menu item, e.g. English, Deutsch... : 0 Menu Clear 1 5 ( ... record header layout, see page 7)4 Further settings if required Quitting the menu with simultaneous storage of all selected settings Quitting the menu without storage of the selected settings (abort) Printing out the current menu settings 8 Printout of a list of Menu the current settings Example of a setting Entry into menu and changing the LC-P45 LANGUAGE/SPRACHE setting from English to Spanish or Italiano Notes: Clear 8 Menu 8 Menu 8 9 Menu 9 9 0 Menu • * These settings are the factory settings; * marks the current setting after a change • The menu settings are stored in a fail-safe manner (battery) • 1) Either Español or Italiano • 2) I/O via LocalCAN interface: no setting necessary. 11 12 4.3 Variable value Time Key sequence 7 3 Def Date 7 Def Lot identification (ID) Factor for multiplication (division) 31 7 4 Def ID Sample code (comment on individual weighing) Sample number start value 5 Code 7 6 Def 1 2 3 7 Def Rounding in multiplication Number of line feeds after printout of weight or result Notes: Entering values of variables 7 2 Def Result 7 Def Range of values Numeric values Hours.minutes.seconds (0.0.0 ... 23.59.59) Numeric values EURO: US: Numeric values Number with max. 20 digits (0 ... 9 plus "." and "-") (0 removes the ID from the record) Numeric values Number with max. 10 digits (0 ... 9 plus "." and "-") [is not stored!] Numeric values 1 ... 9 999 (0 removes the sample number from the record) Numeric values 0.000 001 ... 9 999 999 Numeric values 0.05 : 2 decimal places, the 2nd rounded to 5 1.00 : 2 decimal places, both are = 0 0.001: 3 decimal places, the 3rd to the nearest 1 Numeric values 0 ... 3 • The input process can be checked in the balance display; correction of wrong entry with • The inputted values are stored in a fail-safe manner (exception: sample code) Day.month.year (1.1.00 ... 31.12.99) Month-day-year (1-1-00 ... 12-31-99) Clear 4.4 7 1 Def F Selecting printer function • Entry into selection Selection of function * 1 =Print 2 =Statistics 3 =Totalization 4 =Multiplication 5 =IR Drying LP16/ LJ16 6 =Pipette check 1 On entry, a list of the available functions with their selection numbers are automatically printed out. • Printing of weight values The input process can be checked in the balance display. Correction of wrong entry Clear or or 2 3 • Generation of statistics of weight values • Totalization of weight values 13 14 or or or 4 5 6 • Multiplication (division) of weight values by a factor • Record of drying operation of LP16 and LJ16 IR Dryer The selection of the printer function is stored in a fail-safe manner (battery) • Pipette test for calibrating volumetric dosing apparatus 5 Printer functions 8 8 Menu 9 Menu ... 0 Menu 5.1 Printing out weight values Printing with manual insertion of date and time • Select "No record header" in the menu item RECORD HEADER (page 11) Set date and time page 6 • Print date + time 31 • Print weight 8 8 Menu 9 Menu 7 4 Def ID 7 6 Def 1 2 3 ... ... ... 0 Menu Printing with automatic insertion of date, time, lot identification (ID) and sample number, depending on requirements • Select the record header according to requirements in the menu (e.g.date/time/ID; page 11) • Enter according to requirements (page 12): – Lot identification (ID) – Sample number start value • Print record header and weight automatically 1 or F • Print record header and current sample No. + weight automatically 15 Clear Resets the sample No. to the start value at any time 16 5.2 7 1 Def F 8 Menu 8 Menu 7 4 Def ID 2 9 Generating statistics of a weight series • Select "Statistics" function (page 13) ... ... 1 0 • Select the record header in the menu (page11) Menu • If required, enter lot identification (ID) (page 12) • Load 1st sample and transfer weight value to the statistics F : : • Continue the sample series 2 • If desired, print out intermediate statistics (the sample counter is not reset) Result : min. = smallest value max. = largest value dif. = largest - smallest value max. number of samples = 999 : Clear • Continue the sample series • Conclusion of the sample series with automatic printout of the overall statistics (the sample counter is reset, the statistics memory cleared) 5.3 7 1 Def F 8 Menu 8 Menu 7 4 Def ID 3 9 • Select function "Totalization" (page 13) ... ... 1 F : : 2 Result : Totalizing weight values : Clear 0 • Select record header in the menu (page 11) Menu • If required, enter lot identification (ID) (page 12) • Load 1st sample and transfer weight value to totalization memory max. number of samples = 9 999 max. total = 99 999 999 g • Continue the sample series • If need be, interrupt the sample series for automatic printout of the intermediate total (the sample counter is not reset) • Continue the sample series • Completion of the sample series with automatic printout of the total (the sample counter is reset, the totalization memory cleared) 17 18 5.4 7 1 Def F 8 Menu 4 8 9 Menu 7 4 Def ID 7 4 Def ID 7 4 Def ID 7 4 Def ID • Select function "Multiplication" (page 14) ... ... 0 • Select the record header in the menu (page 11) Menu • According to requirements, enter (page 12): – Lot identification (ID) ... – Sample number start value ... – Factor for multiplication (division) ... – Rounding in multiplication (division) 1 or Multiplying (dividing) the weight by a factor • Loading the weighing sample F • Automatic multiplication of the weight value by the preselected factor and printout of the result together with multiplier and weight 2 • Automatic multiplication by the preselected factor and printout of the result alone Result 5.5 Recording the moisture determination with LP16/LJ16 IR Dryer The LC-P45 automatically inserts date, time and lot identification. 7 1 Def F 8 5 ... 9 5 Menu 7 4 Def ID • Select function "IR Drying LP16/LJ16" (page 14) 0 Menu ... • If required, enter lot identification (ID) (page 12) • Start drying 7 1 Def F 8 Menu 8 Menu 7 4 Def ID • Select "Date/Time/ID" in menu item RECORD HEADER (page 11) • Start drying operation according to instructions in the LP16/LJ16 operating instructions. The LC-P45 prints out the record 5.6 6 9 Pipette test for calibrating volumetric dosing apparatus • Select function "Pipette check" (page 14) ... ... 0 • Select the record header in the menu (page 11) Menu • Enter pipette identification (ID) (page 12) 19 20 7 6 Def 1 2 3 7 Def 7 2 Def Result ... – When necessary enter sample number start value (page 12) ... • Enter the factor z (ISO 8655) to calculate the volume from the mass (page 12). This factor is essentially a function of the water temperature and atmospheric pressure ... • Enter the rounding off convention for the calculated result (page 12) : Y IS LI Q Vo lu U Ma te S TE M S ® 1 F • Dosing the liquid and inclusion of the first volume in the statistics. The dosed volume is calculated automatically from the measured weight by multiplying it with the factor z. The weight and the calculated volume in µl, (V = m x z) are printed out : • Continue the sample series 2 • If desired, print out intermediate statistics (the sample counter is not reset) (page 16) Result : : Clear • Continue the sample series • Conclusion of the sample series with automatic printout of the overall statistics (the sample counter is reset, the statistics memory cleared) (page 16) 5.7 Recording the processes with M-Pac application software packages The LC-P45 prints out the records of the M-Pacs, e.g. CountPac or LabPac. 8 Menu 8 Menu • Work with M-Pac 9 ... 0 Menu • Select "No record header" in menu item RECORD HEADER (page 11) • The LC-P45 is ready for work with M-Pacs. It prints out their records. Note: 21 and 1 F are inactive 22 5.8 8 9 0 Menu Checking a balance with a test weight • Selection and starting the check on the balance (page 11) Menu the menu section ACTIVATE is automatically printed out ACTIVATE: Factory setting Verification Calibration The prompt for weight loading/removal is shown on the balance display. At the same time, the following record is printed out: ---- BALANCE TEST ---- 11.01.2000 14:31:57 ------- * Lo AD METTLER TOLEDO Balance Type: PG503DR-S SNR: 1113000000 Target: 200.000 Actual: 200.001 Diff: 0.001 1000.02 g Internal test done Signature: ....................... --------- END --------- * Minimum weight ≥ 900 in the last 3 places of the display. Exemple: 9.38 g 0.945 kg date and time of verification balance identification ---- BALANCE TEST ---- 11.01.2000 14:31:57 METTLER TOLEDO Balance Type: AB204 SNR: 1113000000 date and time of verification balance identification identification of the test weight displayed weight value of the automatically tared balance Weight ID: ........... difference between target and actual value Target: ........... Actual: 199.9800 g Diff: ........... signature of the tester External test done difference between target and actual value Signature: signature of the tester ....................... --------- END --------- target value of the checking procedure displayed weight value of the automatically tared balance 5.9 9 8 9 0 Calibrating (adjusting) a balance with a calibration weight • Selection and starting the calibration procedure (page 11) Menu Menu ACTIVATE: Factory setting Verification Calibration ------- 500.0 g ------- 0.0 g the menu section ACTIVATE is automatically printed out The prompt for weight loading/removal is shown, as usual, on the balance display. With balances with an internal calibration weight, the automatic calibration routine is started. At the same time, the following record is printed out: Adjusting with external adjustment weight -BALANCE CALIBRATION-- 11.01.2000 14:31:57 METTLER TOLEDO Balance Type: PG503DR-S SNR: 1113000000 balance identification -BALANCE CALIBRATION-- 11.01.2000 14:31:57 METTLER TOLEDO Balance Type: PG503DR-S SNR: 1113000000 Weight ID: ........... Weight: 500.000 g identification number of the test weight Int. calibration done target value of the adjustment procedure Signature: Ext. calibration done Signature: ------- date and time of verification Adjusting with internal adjustment weight signature of the tester ....................... --------- END --------- 0.0 g 23 ....................... --------- END --------- date and time of verification balance identification signature of the tester 24 6 Maintenance 6.1 4 Changing paper • Insertion of a new roll of paper is described on page 5, commercially available, normal paper is used. Order number, see page 28. 1 Changing ribbon Order number, see page 28. 3 7 Def 8 Men 4 5 Code F MET 0 Men 6 u Clea 12 3 2 Resu TLER 9 u ID 1 r 2 • 1 3 lt Prin ter 5 7 Def 8 Men 4 5 Code F MET TLER 6 12 3 2 Resu lt 3 Prin ter 9 u ID 31 Pull paper out of printing unit • 2...4 Remove ribbon cover 31 1 Changing paper and ribbon 0 Men u Clea r • 5 Remove ribbon cartridge • Insert new ribbon (if need be, take up slack with tensioning wheel) and refit ribbon cover • Insert paper and feed through slit in the printing unit as far as it will go • Press and hold until sufficient paper has been fed in 6.2 Maintenance, Service and Cleaning Under normal ambient conditions, the LC-P45 Printer requires practically no maintenance thanks to its rugged construction. The METTLER TOLEDO service department is available should servicing be required. Please ask your responsible METTLER TOLEDO dealer for details. Cleaning As the printer housing is made of top grade, resistant materials, all commercially available cleaning agents may be used. 25 26 7 Malfunctions 7.1 Interpreting the error messages Malfunction/Message Possible cause Rectification Printout unreadable • Ribbon worn/entangled • Service life of printing unit at an end • Change/tension ribbon • Replace printing unit Green pilot lamp does not light up • No power, fuse defective • Switch on power switch, have fuse replaced by METTLER TOLEDO Green pilot lamp flashes slowly • Balance waiting for stability/ cable not attached Green pilot lamp flashes rapidly • Transmission error ---- Interruption --- • Connection cable not attached or older balance (unidir. interface) • Check handshake, initiate print command with PRINT key of balance - Transmission error • Interface parameters of LC-P45 and balance do not match • Set interface parameters ------- ABORT -------- • Calibration has been aborted • Repeat calibration ------ Timeout ------ • Entry incomplete, menu not ended, balance has not sent any weight value in last 30 s • Pause before completion of function must not be longer than 30 s, move balance to more stable location - Battery discharged - • Batteries for clock and settings discharged • Replace batteries; message repeated approx. every 2 hours ------ Overflow ----- • Number of samples for multiplication exceeded ---- Input error ----- • Range of values exceeded ----- Unit error ----- • Different units in totalization, statistics or multiplication ES • Syntax error (error message of balance), balance does not understand LC-P45 instruction EL • Logistical error (error message of balance), balance can not execute LC-P45 instruction 27 • Repeat entry 28 7.2 Printer test The LC-P45 is provided with a self-test which automatically prints out its character set. This allows easier recognition of a possible malfunction of the printing unit. • Switch on LC-P45 + • Switch off LC-P45 • Switch on LC-P45 and at the same time press and hold the feed key for a few seconds • Terminate the printout by switching off the LC-P45 8 Appendix 8.1 Accessories for LC-P45 Printer Accessory Type/Order number Standard equipment Paper roll, set of 5 Ribbon cartridge, black, minimum order quantity 2 Batteries, 2 x UM3/AA (1.5 V) Connection cable LC-P45-balance/scale, LocalCAN, 1 m Extension cable/connection cable LocalCAN, 2 m Extension cable/connection cable LocalCAN, 5 m T-socket for devices with only one LocalCAN socket Connection cable LC-P45-balance, RS-232C, 1 m Connection cable LC-P45-balance, RS-232-C (MiniMettler), 1.5 m Spare printing unit (may be changed only by METTLER TOLEDO service) Power line fuse 230 V (slow-blow 100 mA,250 V) + 115 V (slow-blow 200 mA,250 V) (may be changed only by METTLER TOLEDO service) 00072456 00065975 commercially available LC-LC1 cable, 00229154 LC-LC2 cable, 00229115 LC-LC5 cable, 00229116 LC-LCT, 00229118 RS9 (m)–RS9 (f) cable, 11101051 00229029 – – 2 rolls 1 piece 2 piece 1 piece – – – 1 piece – – – 8.2 In/Out HandShake GND + 5 V/ 20 mA 1 5 6 9 I/O interfaces The LC-P45 has a LocalCAN and an RS-232-C interface for the attachment of METTLER TOLEDO instruments and peripherals. One or other can be used, but if both are connected only the LocalCAN is active. LocalCAN interface • Bus interface with 2 4-pin looped sockets for the attachment of balances/scales/instruments and peripherals. • No transmission parameters need be adapted. RS-232-C interface • 9-pin male connector (pin assignment as IBM laptop) • Matching to other device (transmission parameters) in the menu; see page 11 LocalCAN RS-232-C • The handshake lines are active when "hardware" has been selected in menu item HANDSHAKE • The standard cable 00229029 has no handshake lines Connection example A scale and a PC are attached to the LC-P45 via the LocalCAN bus. LC-P45 29 30 Attachment to METTLER TOLEDO instruments, additional hardware, available functions (software version 2.40) in balance display Checking of key entries LC-P45 Print command from Printing balance identification documented Checking of balance Calibrating documented Additional hardware date, ID Record header with time, multiplication Remarks Statistics, totalization, Attachment to balance or instrument Available functions Printing weight Attachment to LC-P45 Printing record 8.3 AB, PB, SB, CB, GB, B * 9 15 m l l l l l l l l AB, AB-S, PB, PB-S, SB, ** CB, GB, B RS o l l l l l l l l m l l l l l l l l o l l l l l l l l m l l l l l l l l AG, PG 9 PG-S with RS232C RS PG-S with LocalCAN Option 9 PR 9 m l l l l l l l l AT/MT/UMT PM/SM/AM PJ/AJ Option 018/019 1 1 1 14 o o o l l l l l l l l l l l l l l l l l l l l l l l l BB M3/UM3 with Option 03 1 13 o o 2 l l l l l l l l l AE with Option 011 AE with Option 012 3 13 3 o o l l l l l l l PE with Option 016 PE with Option 017 13 o o 4 5 l l l l l l l in balance display Checking of key entries LC-P45 Print command from Printing balance identification documented Checking of balance Calibrating documented date, ID Additional hardware Record header with time, multiplication Statistics, totalization, Remarks Printing record Attachment to balance or instrument Available functions Printing weight Attachment to LC-P45 LP16/LJ16 PM-Pacs 1 1 13 o 12,13 o l l l ID1 ID3 with Option 082 ID5 with Opion 082/089 10 10 10 o o o 6 6 6 l l l l l l l l l l l l l l l l l l IF with 504949 DT 13 o o 6 8 l l l l l l l DL18/21/25/35 FP62 13 13 o o 7 7 l l 31 32 Legend and general remarks to the attachment of the LC-P45 to METTLER TOLEDO instruments Continuation legend Legend Connection cable to LC-P45 1 2 3 4 000229029 is standard Order number: 00042931 00059759 included in option Order number: 000229029 5 6 7 8 Order number: 00047936 Order number: 00504376 Order number: 00017842 Produce cable → page 29 9 RS LC-LC1 cable is standard RS9 (m) – RS9 (f) cable is standard o = LocalCAN m = RS-232-C/CL CL/RS-Interface converter 10 Interface mode: DIALOG MODE (standard setting). If the terminal is in break condition, it has to be switched off and on again. The LC-P45 can print maximally 24 characters a line, additional characters will be discarded. 12 Printout of Pac record only 13 Check of key entries via printout only, the balance display is inactive. 7 3 Example: Setting the time. After the set time is printed out: Def -> 13:55 14 Documentation of calibration after balance software version 10.45. 15 For the AB, PB, SB, GB, CB and B balances and scales earlier than 02.97, the interface "LC-B Option" is required. CL249, Order number: 00059759 Adapter cable and hand switch Order number: 00047473 Order number: 00042500 * Balance models earlier than 02.97 **Balance models after 02.97 General remarks • With or 1 F only stable weight values can be printed out; to print out unstable values, set the balance to "send all" and give the print command with its PRINT key. • Do not set the balance to "send all" for statistics, totalization and multiplication. • If the PRINT key of the balance is pressed, the weight will be printed out without record header 8.4 Technical data Printer Printing unit dot matrix printer 5x9 dots, 24-character line length, Epson/IBM character table No. 4 Printing speed faster than 1 line per second Ribbon cartridge exchangeable, black Paper roll normal paper, 58 x dia. 51 mm, integrated in housing, commercial size Printer functions see page 3 Clock date representation EURO or US format, leap year taken into account Interface LocalCAN and RS-232-C bidirectional Transmission parameters LocalCAN fixed adjustment Transmission parameters RS-232-C transmission rate 1200, 2400* baud, parity even*, odd, no character length 7 bit*, 8 bit Handshake Bidirectional handshake: off*, xon/xoff, hardware Printer buffer 128 characters * = factory setting 33 34 Designed test conditions Power supply voltage, Frequency 115 V oder 230 V, admissible fluctuations -20%+15%, 50/60 Hz Current consumption 140 mA or 70 mA Height 4000 m Temperature range 5...40 °C Humidity max. relative humidity 80% for temperatures to max. 31 °C linear decreasing to 50% at 40 °C Installation category II Pollution degree 2 Dimensions / weight W x D x H = 157 x 210 x 85 mm / net 1.5 kg (incl. paper roll) Leer To protect your METTLER TOLEDO product's future: METTLER TOLEDO service assures the quality, measuring accuracy and preservation of value of all METTLER TOLEDO products for years to come. Please send for full details about our attractive terms of service. Thank you. *705108* Subject to technical changes and to the availability of the accessories supplied with the instruments. © Mettler-Toledo AG 2009 705108D Printed in Switzerland 0909/2.12 Mettler-Toledo AG, Laboratory & Weighing Technologies, CH-8606 Greifensee, Switzerland Phone +41-44-944 22 11, Fax +41-44-944 30 60, Internet: http://www.mt.com
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement