DA-10825 - Worldwide

QuickSpecs
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
MODELS
Compaq UPS T1000 XR, T1500 XR, and T2200 XR
Tower UPS “XR” Models
North America / Latin America Models
204155-001 – T1000 XR
204155-002 – T1500 XR
204451-001 – T2200 XR Low Voltage
204451-002 - T2200 XR High Voltage
Japan Models
204155-291 – T1500 XR
204451-291 – T2200 XR
International Models
204155-B31 – T1000 XR
204155-B32 – T1500 XR
204451-B31 – T2200 XR
Extended Runtime Module (ERM) Options
218967-B21 - ERM, T1000 XR
218969-B21 - ERM, T1500/T2200XR
Option Cards
192185-B21 - Six Port Card
192189-B21 - SNMP/Serial Port Card
OVERVIEW
The new Tower UPS “XR” models feature a unique design, improved and easy-to-configure front panel display, and extended run capability. The Compaq
UPS “XR” models denote “eXtended Runtime Capable” UPS models. Ideal for workstations up to the distributed enterprise environments, the “XR”
Uninterruptible Power Systems (UPSs) are an enhancement of the current UPS products, and are an integral part of the proven family of Compaq Power
Management Products.
Compaq UPSs protect your computer equipment and your critical data against damage due to inconsistent and fluctuating power. They enable you to
continue working during sudden brief events of power outage, and automatically save your data, close applications, and stage a systematic shutdown
during an extended power outage. Bundled with Compaq Power Management Software, the UPSs allow customers to also perform a remote shut down of
applications and connected equipment if required.
KEY FEATURES
•
Ease of configuration via enhanced front panel display
•
Intelligent manageability with bundled Compaq Power Management software
•
Greater system uptime with support for Extended Runtime Module (ERM)
•
Long-term battery reliability with Compaq Enhanced Battery Management
•
Hot-Swappable battery
•
Enhanced system flexibility with independently controllable load segment
•
One option slot that supports Compaq UPS option cards
•
Backed by a limited three-year warranty, Compaq’s Pre-Failure warranty, and a $25,000 load protection guarantee
Note: Certain restrictions and exclusions apply. Consult the Compaq Computer Support Center for details. In Canada, consult the Product
Information Centre at 1-888-88-COMPAQ.
DA-10825
World Wide — Version 4 — September 26 2002
1
QuickSpecs
KEY FEATURES
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
(continued)
1
2
3
1. LED display
2. Button controls
3. Removable front panel
PRODUCT HIGHLIGHTS
Compaq UPS Products
Compaq has developed a full-range of Uninterruptible Power Systems (UPSs) that protect and manage computer systems ranging from individual
workstations to several groups of servers. Compaq UPS s are available in both tower and rack form factors.
Tower UPS “XR” Models
The UPS “XR” models are the new Compaq UPS models that support optional Extended Runtime Modules. In the Tower UPS “XR” category, Compaq
offers the T1000 XR, T1500 XR and T2200 XR models. These UPSs are designed to provide maximum protection for workgroup, departmental, and
enterprise server platforms.
Easy Configuration via Enhanced Front Panel Display
The new UPS models have an enhanced front panel display. LED display lights and switch membrane is integrated into the front panel that can be
configured through a four button control (three buttons for UPS power control and one button under the front bezel for configuration).
Increased System Uptime with Extended Runtime Modules
The new Compaq UPS “XR” models support extended runtime modules which extend your overall runtime.
Investment Protection with Compaq Enhanced Battery Management
Compaq UPSs incorporate Enhanced Battery Management; an exclusive, patented technology that doubles battery service life, optimizes battery
recharge time, and provides advance notice of pending battery failure. With Enhanced battery Management, you have a lower overall cost of ownership
and receive the best in the industry protection for your critical equipment.
Enhanced System Flexibility with Compaq Option Cards
Compaq UPS “XR” models are equipped with a standard serial port via an internal slot. This slot supports two option cards; the Six Port Card and the
SNMP/Serial Port Card. These option cards seamlessly integrate into the back of the UPS and provide increased system flexibility.
Intelligent Manageability
Compaq Power Management Software, an integrated component of Compaq Insight Manager, the industry-leading hardware management platform, is
included with these UPS models. The Compaq Power Management Software enables you to monitor and control Compaq UPSs locally or remotely. This
software is a versatile, fully configurable, alert response tool that gives system administrators a full overview of the network’s conditions. It enables you to
monitor system status and power conditions, configure shut down timing, customize alert messages, and perform UPS diagnostic checks quickly and
easily.
Ease of Maintenance with Hot-Swappable Battery
Compaq UPSs are designed with simple access through the front panel. Users can safely install new battery without ever powering down connected
computer equipment.
DA-10825
World Wide — Version 4 — September 26 2002
2
QuickSpecs
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
P R O D U C T H I G H L I G H T S (continued)
Independently Controllable Load Segments
Compaq Tower UPS “XR” models incorporate independently controllable load segments that allow for prioritized shutdown of multiple servers. Managed
through Compaq Power Management software, each individual load segment can be pre-configured by the system administrator to conduct a prioritized
shutdown extending the runtime of your most critical servers. In addition, this feature promotes energy and power conservation by facilitating scheduled
shutdown and startups during low usage such as weekends and holidays.
Compaq Quality
Compaq’s hardware qualification is the toughest in the industry. Extensive evaluation, testing, product improvement, and an unsurpassed warranty
guarantee the highest level of system protection, electrical performance, product quality and compatibility.
Warranty
Compaq UPSs are covered by a three-year, limited warranty. Also, standard on all Compaq UPS units, is our exclusive Pre-Failure Warranty, which
extends the advantage of a Compaq three-year, limited warranty by applying it to the battery before it actually fails. This warranty is offered worldwide.
Specifically, the Pre-Failure Battery Warranty ensures that when customers receive notification from Compaq Power Management Software that the
battery may fail, the battery is replaced free of charge under the warranty.
Note: $25,000 Computer/Load Protection Guarantee is also provided, in addition to the Compaq three year, limited warranty.
SERVICE & SUPPORT, CAREPAQ AND WARRANTY INFORMATION
Warranty Upgrade Options
• Response – Upgrade on-site response from next business day to same day 4 hours
• Coverage – Extend hours of coverage from 5 days x 9 hours to 7 days x 24 hours
• Duration – Select duration of coverage for a period of 1, 3, or 5 years
CarePaq Information
For CarePaq (hardware & software) information, as well as orderable part numbers, please refer to the URL listed below:
http://www.compaq.com/services/carepaq/index.html. Note: This Web site is available in English only.
U P S T 1 0 0 0 XR M O D E L S E L E C T I O N M A T R I X
Part Number
Low-Voltage Models
T1000 XR, NA
204155-001
Operating Voltage Settings Power Out (VA/ Watts)
120V
Note:
High-Voltage Models
T1000 XR, INTL
204155-B31
1000/700
Input Connection
Output Connection
Load Segments
5-15P
(6)5-15R
2
(6) IEC 320 C13
2
Part Number 204155-001 is user selectable for 110V, or 120V via front panel.
230V
1000/700
IEC 320 C14 input connector
Note: Part Number 204155-B31 is user selectable for 220V, 230V, or 240V via front panel.
Extended Runtime Module Option
ERM, T1000 XR
218967-B21
Shipping Dimensions
14.50 x 22.0 x 25.0 in /
368 x 559 x 635 mm
UPS T1000 XR Kit Contents
Unit Dimensions (WxHxD)
Shipping Dimensions
Unit Weight
Shipping Weight
DA-10825
World Wide — Version 4 — September 26 2002
Shipping Weight
77 lbs / 35 kg
Compaq UPS T1000 XR
Compaq Power Management Software CD
Power Products Documentation CD
6’ UPS to computer interface cable
(The International model includes 2 IEC to IEC power cords in addition to the above)
6.37 x 9.50 x 16.2 in / 161 x 241 x 411 mm
14.50 x 22.0 x 21.0 in / 368 x 558 x 533 mm
34.45 lbs / 15.62 kg
43 lbs / 19.5 kg
3
QuickSpecs
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
U P S T 1 5 0 0 XR M O D E L S E L E C T I O N M A T R I X
Part Number
Low-Voltage Models
T1500 XR, NA
204155-002
T1500 XR, JPN
204155-291
Operating Voltage Settings Power Out (VA/ Watts)
Note:
High-Voltage Models
T1500 XR, INTL
204155-B32
Input Connection
Output Connection
Load Segments
Attached 6’ power cord with
NEMA 5-15P
(6) 5-15R
2
Attached 6’ power cord with
NEMA 5-20P
Part Number 204155-002 is user selectable for 110V, or 120V via front panel.
(6) 5-20R
2
(6) IEC 320 C13
2
120V
1440/1050
100V
1500/1050
230V
1500/1050
IEC 320 C14 input connector
Note: Part Number 204155-B32 is user selectable for 220V, 230V, or 240V via front panel.
Extended Runtime Module Option
ERM, T1500/T2200 XR
Shipping Dimensions
Shipping Weight
218969-B21
14.50 x 22.0 x 25.0 in /
77 lbs / 35 kg
368 x 559 x 635 mm
UPS T1500 XR Kit Contents
Compaq UPS T1500 XR
Compaq Power Management Software CD
Power Products Documentation CD
6’ UPS to computer interface cable
(The International model includes 2 IEC to IEC power cords in addition to the above)
Unit Dimensions (WxHxD)
6.37 x 9.5 x 18.2 in / 161 x 241 x 462 mm
Shipping Dimensions
14.5 x 22.0 x 25.0 in / 368 x 558 x 635 mm
Unit Weight
54.8 lbs / 24.8 kg
Shipping Weight
61 lbs / 27.6 kg
U P S T 2 2 0 0 XR M O D E L S E L E C T I O N M A T R I X
Part Number
Low-Voltage Models
T2200 XR, NA-Low
204451-001
Operating Voltage Settings Power Out (VA/ Watts)
T2200 XR, JPN
204451-291
Note:
High-Voltage Models
T2200 XR, INTL
204451-B31
T2200 XR, NA-High
204451-002
Input Connection
Output Connection
Load Segments
120V
1920/1600
Attached 6’ power cord with
NEMA 5-20P
(6) 5-15R & (2) 5-20R
3
100V
2200/1600
Attached 6’ power cord with
NEMA 5-30P
(6) 5-15R & (2) 5-20R
3
Part Number 204451-001 is user selectable for 110V, or 120V via front panel.
230V
2200/1600
IEC 320 C14 input connector
(9) IEC 320 C13
3
208V
2080/1600
IEC 320 C14 input connector
(9) IEC 320 C13
3
Note: Part Number 204451-B31 is user selectable for 220V, 230V, or 240V via front panel.
Note: For UPS part number 204451-002, a NEMA 6-15P input power cord is provided.
Extended Runtime Module Option
ERM, T1500/T2200 XR
Shipping Dimensions
Shipping Weight
218969-B21
14.50 x 22.0 x 25.0 in /
77 lbs / 35 kg
368 x 559 x 635 mm
UPS T2200 XR Kit Contents
Compaq UPS T2200 XR
Compaq Power Management Software CD
Power Products Documentation CD
6’ UPS to computer interface cable
(The International model includes 2 IEC to IEC power cords in addition to the above)
Unit Dimensions (WxHxD)
8.1 x 9.5 x 18.8 in /205 x 241 x 477 mm
Shipping Dimensions
15.5 x 20.5 x 26.0 in / 393 x 520 x 660 mm
Unit Weight
70 lbs / 31.7 kg
Shipping Weight
80 lbs / 36.2 kg
DA-10825
World Wide — Version 4 — September 26 2002
4
QuickSpecs
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
C O M P A Q U P S T 1 0 0 0 XR , T 1 5 0 0 XR , A N D T 2 2 0 0 X R S P E C I F I C A T I O N S
Electrical Input
Electrical Output
Battery
Communications
Environmental and Safety
DA-10825
Voltage Range
Frequency
Connections
Online Efficiency
Surge Suppression
100, 120, 208 and 230V models.
See Model Selection Matrix for nominal and user selectable voltage settings
50 / 60 Hz
See Model Selection Matrix
95%
High Energy 6500A peak
Online Regulation
–30% to +20% of nominal voltage
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Sine wave
Connections
See Model Selection Matrix
Output Protection
Re-settable circuit protectors
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Recharge Time
<3 hours to 90% usable capacity; <24 hours for complete recharge
Serial Ports
Standard communication port (ships with communication cable)
LED Indicators
(11) LED status display with On Line,On Battery,Replace Battery,Overload Indicator, 76%
to100% load, 51%to 75% load, 26% to 50% load,0% to 25% load,Site Wiring Fault
Indicator, General Alarm and Configure Mode On; (4) push button switches for On/Off,
Alarm, Standby(turn output segments off), and Configure button
Operating Temperature
50° to 104°F / 10° to 40°C
Transit and Storage
Temperature
5° to 131°F / –15° to 55°C
Humidity (Operation)
20% to 80% (non-condensing)
Humidity (Non-operating)
5% to 95%
Operating Altitude
Up to 6,562 ft / 2000m above sea level
Transit and Storage Altitude
Up to 30,000 ft / 9,144m above sea level
Audible Noise
Less than 53 dBA
Safety Markings
FCS, UL, CSA, VDE, NEMKO, FIMKO, DEMKO, SEMKO, NOM
Safety Certifications
UL1778; CSA22.2
EMC Markings
FCC; CISPR; VCCI; CE
Emissions
FCC CFR 47, Part 15 Class A, EN50091-2
Immunity
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
Surge Suppression
Conforms to IEEE 587B and ANSI C62.41
World Wide — Version 4 — September 26 2002
5
QuickSpecs
Compaq Uninterruptible Power System
T1000 XR, T1500 XR, and T2200 XR
ESTIMATED BACKUP TIMES CHART (IN MINUTES)
Load (VA)
UPS
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1200
1400
1500
1800
2000
2200
35
31
28
24
21
17.5
14
13
11
9.5
8
6.5
6
5.75
5.5
5.25
5
UPS T1000 XR
UPS+1ERM UPS+2ERMs
160
140
124
105
90
75
60
56
52
47
43
38
35
32
30
27
25
300
276
255
234
212
194
170
155
138
120
104
88
70
65
62
58
55
UPS
60
54
50
46
42
38
34
30
26
22
17
16.5
16
15
14
13
12
9
7
6.5
UPS T1500 XR
UPS+1ERM UPS+2ERMs
230
215
196
185
170
155
140
125
110
95
79
75
72
69
65
61
59
44
37
33
415
390
360
335
310
284
255
228
200
174
146
140
132
126
120
114
108
81
69
63
UPS
44
42
40.5
39
37.5
36
35
32
31
29
27.5
26
24
21
19.5
18
16
13
11
9.5
6
5.5
5
UPS T2200 XR
UPS+1ERM UPS+2ERM
s
197
380
190
364
183
349
175
330
165
312
160
300
154
384
146
369
139
350
132
335
124
319
116
302
108
285
102
269
93
251
86
238
79
220
56
170
49
136
42
120
36
70
31
61
26
55
Note: Backup times are estimated for typical applications. Actual performance will depend on load and battery conditions.
COMPATIBILITY
Compatible with all Compaq computer systems and servers ranging from individual workstations to distributed enterprise and other Compaq equipment
(in tower form factor).
Compaq PCs use genuine Microsoft® Windows®
www.microsoft.com/piracy/howtotell
Compaq and the Compaq logo are registered in the U.S. Patent and Trademark Office.
AlphaServer, AlphaStation, OpenVMS, ProLiant, SANworks, StorageWorks, TruCluster, and Tru64 are trademarks of Compaq Information Technologies
Group, L.P. in the U.S. and/or other countries.
Windows is a registered trademark of Microsoft Corporation.
UNIX is a registered trademark of The Open Group, Inc.
Intel is a registered trademark of Intel Corporation.
All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.
© 2002 Compaq Computer Corporation
DA-10825
World Wide — Version 4 — September 26 2002
6