Whirlpool UXT4230AYS User manual

30"UnderCabinetHood UXT4230AY KeyFeatures • Convertible Under Cabinet Hood (New Design) • Vertically Exhausts up to 225 CFM with a 3 1/4" x 10" Rectangular or 7" Round Duct • Axial Fan • Covered, 75-Watt Incandescent Light with 2 Light Levels • Variable Speed, Rotary Control • Dishwasher Safe, Washable Grease Filters 30" Under Cabinet Hood UXT4230AY Specifications Location Requirements Installation Clearances Installation Requirements IMPORTANT: Observe all governing codes and ordinances. model no. ■ It is the installer’s responsibility to comply uxt4230ay with installation Convertible Type clearances specified on the model/serial rating plate. The model/serial rating plateduct is located type inside the range hood on the left wall. Yes Round 7" ■ Range hood location should away from strong Rectangular 3 1/4"be x 10" Yes draft areas, such as windows, doors and strong heating vents. Yes Washable Grease Filter Cabinet opening dimensions that vertical cfm are shown must be used. Location Requirements Given dimensions provide7"minimum clearance.232 Consult the Roundcodes IMPORTANT: Observe all governing and ordinances. cooktop/range manufacturer installation instructions before 3 1/4"responsibility x 10" Rectangular ■ making It is the any installer’s to comply with213 installation cutouts. clearances specified on the model/serial rating plate. The horizontal cfm ■ Grounded electrical outletisislocated required. See “Electricalhood on model/serial rating plate 216 3 1/4" x 10" inside the range Requirements” the left wall. section. vertical Sones ■ openings in ceilingshould and wall rangestrong hood will be ■ All Range hood location bewhere away from 6.5 draft areas, 7" Round installed must be sealed. such as windows, doors and strong heating vents. 3 1/4" x 10" Rectangular 7 ■ range hoods are factory setare forshown ventedmust installations. ■ These Cabinet opening dimensions that be used. general information Models that are capable ofminimum being installed as non-vented Given dimensions provide clearance. Consult the 6.4 Horizontal Sones (recirculating) charcoalinstallation filters. Seeinstructions the “Accessories” cooktop/rangerequire manufacturer before Control Variable Speed, Rotary section charcoal filter kit. making to anyorder cutouts. Installation Clearances C ■ B D A C B 3 1/4" x 10" (included) Adapter/Vent Connector ■ Grounded electrical outlet is required. See 7" “Electrical Optional For Mobile Home Installations section. Blower Axial Fan The Requirements” installation of this range hood must conform to the Manufactured Home Construction 24 ■ All openings in ceiling and wall Safety where Standards, range hood will be 2 LevelTitle Lighting CFR, Part 328 (formerly the Federal Standard for Mobile Home Incandescent (75-Watt) installed must be sealed. Construction and Safety, titleCompliant 24, HUD, Part 280) or Title Yeswhen such ■ These range hoods are24the factory set forforvented installations. standard is not applicable, standard Manufactured Home Range/Cooktop Compatibility Up 40K BTU Models 1982 that are capable of being astonon-vented Installation (Manufactured Homeinstalled Sites, Communities and (recirculating) require filters. Seeedition, the “Accessories” Approx. Shippingcharcoal Weight (lbs.) 13or with local Setups) ANSI A225.1/NFPA 501A*, or latest section to order charcoal filter kit. codes. optional accessories 7" Round Damper For Mobile Home Installations Product Dimensions 7" Round Adapter/Vent Connector D A W10355451 W10388168 The installation of this range hood must conform to the Power Cord W10355452 Manufactured Home Construction Safety Standards, Title 24 CFR, PartConvertible 328 (formerly the Federal Standard Mobile Home to Non-Vented Mode 6⁹⁄₁₆" (16.7 cm)for W10355450 (Recirculation Kit) Part 280) or when such Construction and Safety, title 24, HUD, A. 18" (45.7 cm) min. clearance - upper cabinet to countertop E B. 18" (45.7 cm) to 24" (61.0 cm) suggested max. - bottom of range hood to cooking surface C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) models and 36" (91.4 cm) min. cabinet width for 36" (91.4 cm) models. D. 13" (33.0 cm) cabinet depth E. 36" (91.4 cm) base cabinet height ⁷⁄₈" standard is not standard for Manufactured (2.2 3 1/4" xcm) 10"applicable, Rectangularthe Damper Kit W10398259 Home Installation 1982 (Manufactured Home Sites, Communities and Color Availability W,T,B,S Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with1"local 4¹⁵⁄₁₆" (2.5 Note: CFMs are based on IEC standard * W-White, B-Black, S-Stainlesscm) Steel codes. (12.5 cm) ⁷⁄₈" Product (2.2 Dimensions Dimensions cm) 9" (22.9 cm) 6⁹⁄₁₆" (16.7 cm) ⁷⁄₈" 29¹⁵⁄₁₆" (76.0 cm) or (2.2 cm)35¹⁵⁄₁₆" (91.0 cm) 2¹⁄₈" (5.4 cm) 18⁵⁄₈" (47.3 cm) 1" (2.5 cm) 4¹⁵⁄₁₆" (12.5 cm) Venting Requirements Dimensions are for planning purposes- upper only. cabinet to countertop A. 18" (45.7 cm) min. clearance For complete details, see Installation Instructions packed with product. 18" system (45.7 cm)must to 24"terminate (61.0 cm) suggested max. - bottom range ■ B. Vent to the outdoors, exceptoffor nonSpecifications subject to change without notice. hood to cooking surface vented (recirculating) installations. C. 30" (76.2 cm) min. cabinet opening width for 30" (76.2 cm) ■ Do not terminate the vent system in an atticforor36" other enclosed models and 36" (91.4 cm) min. cabinet width (91.4 cm) models. area. D. 13" (33.0 cm) cabinet depth ■ E. Do not usecm) a 4" (10.2 cm) height laundry-type wall cap. 36" (91.4 base cabinet ■ ⁷⁄₈" (2.2 cm) 29¹⁵⁄₁₆" (76.0 cm) or 35¹⁵⁄₁₆" (91.0 cm) E 9" (22.9 cm) 2¹⁄₈" (5.4 cm) 18⁵⁄₈" (47.3 cm) ■ ■ ■ ■ Use a 7" (17.8 cm) round metal vent or a 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular metal vent, depending on your model. Rigid metal vent is recommended. Plastic or metal foil vent is Venting Requirements not Ventrecommended. system must terminate to the outdoors, except for nonvented (recirculating) installations. The length of vent system and number of elbows should be kept to a minimum to provide efficient Do not terminate the vent system in an performance. attic or other enclosed area. Do not use a 4" (10.2 cm) laundry-type wall cap. ■ Use a 7" (17.8 cm) round metal vent or a 3¹⁄₄" x 10" (8.3 x ®Registered trademark/™ Trademark of Whirlpool, U.S.A. ©2011. All rights reserved. AA105059 25.4 cm) rectangular metal vent, depending on your model. Rigid metal vent is recommended. Plastic or metal foil vent is
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Related manuals
Download PDF
advertisement