Daikin | FFQ18LVJU | Daikin Super Multi Plus Brochure

For Residential & Light Commercial Applications
4‐Ton 8‐Zone Multi‐Split Heat Pump System
EXPERTISE AND INNOVATION
The 8‐Zone Multi‐Split System is the ultimate, flexible solution for individual zone comfort. Connecting up to 8 indoor units to a single outdoor unit reduces installation space and costs while maximizing comfort and energy savings. With a choice of three indoor unit types in a wide range of capacities, the 8‐Zone Multi‐Split allows mixed and matched combinations for absolute comfort in almost any residential application.
ENERGY EFFICIENCY
Integrated with an inverter “variable speed” compressor, Daikin 8‐Zone Multi‐Split systems deliver the capacity required to maintain desired room conditions, typically reducing energy consumption by 30% compared to traditional fixed speed systems. This technology minimizes temperature fluctuations and provides continuous cooling and heating comfort with maximum energy savings.
INDIVIDUAL COMFORT AND CONTROL
The standard wireless controller provides individual temperature control at the click of the button. Most Indoor units are also compatible with the new Daikin ENVi intelligent thermostat, offering a more advanced solution, designed with energy savings performance in mind. With the freedom to access, program and control the system from a smart phone, tablet, or computer, users can have peace of mind ‐ anytime, anywhere.
Note: The Daikin ENVi thermostat is not compatible with the FFQ Indoor Units
BUILT‐IN RELIABILITY
All major components are engineered and manufactured by Daikin, ensuring maximum performance, reliability and efficiency. The standard warranty provides a solid level of protection on the 8‐Zone Multi‐Split system. Systems installed by an authorized Daikin Dealer who has completed Daikin’s advanced training can take advantage of Warranty Plus – the best warranty in the industry.
Find a Daikin Dealer near you at www.daikinac.com.
DESIGN FLEXIBILITY
The 8‐Zone Multi‐Split System can be combined with a variety of ducted and ductless models with a total of 15 indoor unit variations.
Indoor Unit Availability
Capacity
Indoor Type
Wall Mount
Slim Duct
2' x 2' Cassette
7 MBH
9 MBH
12 MBH
15 MBH
CTXS_H, CTXS_LV, FTXS_LV
Wall Mounted Unit
Blends with any décor with it’s sleek and sophisticated design
Enhanced indoor air quality with the titanium apatite photocatalytic air purification filter which absorbs microscopic particles and decomposes odors
Increased energy savings with the intelligent eye function which reduces operation in unoccupied spaces
FDXS_LV, CDXS_LV
Concealed Slim Duct
Maximized floor and wall space with it’s compact and concealed design
Undisturbed comfort with low operating sound levels
Cleaner air with the removal or airborne dust particles by the standard mold proof air filter
FFQ_LV
2’ X 2’ Ceiling Cassette
Enhanced comfort with uniform airflow and temperature distribution
Draught free protection with horizontal air discharge
Simple installation with an easy‐to‐fit decoration panel that blends with any interior design
Easy maintenance with an easy‐to‐clean grille and washable long life filter
BPMKS
Branch Provider Unit
Varies the refrigerant volume to meet the cooling or heating requirements of each room connected to the system.
Facilitates zone on/off and capacity control to operate rooms individually via zone temperature controls
Simple installation with flare nut connections
REFNET joint
Reduces the amount of work involved in installation and increases the reliability of the system.
18 MBH
24 MBH
LEADING TECHNICAL PERFORMANCE
Up to 8 indoor units can be connected to a single outdoor unit
A High Efficiency solution with optimum flexibility to provide zoning for with the connection of up to 8 indoor units utilizing long pipe lengths, ease of installation with standardized line‐sets, simplified electrical requirements and staged installations
Outdoor Units – RMXS48LVJU
Model Name
Nominal Capacity (Cooling / Heating)
SEER / HSPF
EER / COP
Btu/h
RMXS48LVJU
48,000 / 54,000
Non Ducted
Mixed
Ducted
Non Ducted
Mixed
Ducted
18.8 / 11.3
16.5/10.5
14.1/9.6
10.3/3.0
9.8/2.9
9.3/2.7
Power Supply
Minimum Circuit Amps
A
Maximum Overcurrent Protection
A
Sound Pressure - (Cooling/Heating)
dB(A)
Connection Ratio (Max Capacity for BPMKS Boxes)
Number of Connectable Indoor Units
Number of Connectable BP Units
Total System Piping Length
ft. (m)
Max. Piping Length(OU to BP Box)
ft. (m)
Max. Piping Length(IU to BP Box)
ft. (m)
Total Piping Length (OU to BP Box)
ft. (m)
Total Piping Length (BP to IU)
ft. (m)
Max. Piping Height (OU to IU)
ft. (m)
Max. Piping Height (IU to BP Box)
ft. (m)
Max. Piping Height (BP to BP Box)
ft. (m)
Piping Connection Kit
Operating Range – (Cooling/Heating)
°F DB
Dimensions (H x W x D)
in.
Net Weight
lbs.
208/230V - 1Ø - 60Hz
27.0
30.0
56/58
50 - 130%
2 to 8
1 to 3
440 (135)
180 (55)
49 (15)
180 (55)
262 (80)
98 (30)
98 (30)
49 (15)
KHRP26A22T
23 – 115/5 - 75
52-15/16 x 35-7/16 x 12-5/8
283.0
Indoor Units - CTXS_HVJU, CTXS_LVJU, and FTXS_LVJU Wall Mounted Units
Model Name
Airflow-Wet (H/M/L/SL)
Airflow-Dry (H/M/L/SL)
Sound Pressure - Cooling (H/M/L/SL)
Sound Pressure - Heating (H/M/L/SL)
Liquid (O.D.)
Piping Connections
Gas (O.D.)
Up to 2 Zones Up to 3 Zones
BP Units
Model Name
BPMKS048A2U
Power Supply
Power Consumption
W
Running Current
A
Sound Pressure - (Cooling/Heating)
dB(A)
Number of Connectable Indoor Units
Min. Connection Combination
Max. Connection Combination
Outdoor Unit Side
in.
Liquid Indoor Unit Side
in.
Piping
Connection Type
Connections
Outdoor Unit Side
in.
(O.D.)
Gas
in.
Indoor Unit Side
Connection Type
Dimensions (H x W x D)
in.
Net Weight
lbs.
Nominal Conditions:
Cooling Mode
Indoor: 80 °F DB / 67 °F WB
Outdoor: 95 °F DB
Pipe Length: 25 ft.
Level Difference: 0 ft.
0.6‐Ton
CTXS07LVJU
332/261/194/145
350/290/233/219
38/32/25/22
38/33/28/25
Ø 1/4
Ø 3/8
Ø 5/8
0.75‐Ton
Single phase 60Hz 208/230V
10
10
0.05
0.05
32/32
32/32
1 to 3
1 to 2
7,000
7,000
62,000
48,000
Ø 1/4 x 2
Ø 1/4 x 3
Ø 1/4 x 2
Ø 1/4 x 3
Flare
Flare
Ø 5/8 x 2
Ø 5/8 x 3
Ø 5/8 x 2
Ø 5/8 x 3
Flare
Flare
7-1/16 x 11-9/16 x 13-3/4
18.0
20.0
Heating Mode
Indoor: 70 °F DB
Outdoor: 47 °F DB / 43 °F WB
Pipe Length: 25 ft.
Level Difference: 0 ft.
1.0‐Ton
CTXS09HVJU CTXS12HVJU
388/335/283/388/335/283/400/357/314/400/357/314/44/40/35/45/41/36/44/39/34/45/40/35/Ø 1/4
Ø 1/4
Ø 3/8
Ø 3/8
Ø 11/16
Ø 11/16
11-7/16 x 31-5/16 x 9-3/8
20.0
20.0
BPMKS049A3U
1.25‐Ton
Note:
Specifications are subject to change without notice.
1.5‐Ton
2.0‐Ton
FTXS15LVJU
FTXS18LVJU
FTXS24LVJU
568/477/385/360 583/484/385/360 643/494/350/328
593/505/417/371 625/526/431/399 699/572/445/403
45/40/35/32
46/41/36/33
51/44/37/34
43/38/33/30
45/40/35/32
48/42/37/34
Ø 1/4
Ø 1/4
Ø 1/4
Ø 1/2
Ø 1/2
Ø 5/8
Ø 5/8
Ø 5/8
Ø 5/8
13-3/8 x 41-5/8 x 9-3/4
31.0
31.0
31.0
CFM
CFM
dB(A)
dB(A)
in.
in.
Condensate Drain Connection (O.D.) in.
Dimensions (H x W x D)
in. 11-5/8 x 31-1/2 x 8-7/16
Net Weight
lbs.
20.0
Indoor Units - FDXS_LVJU and CDXS_LVJU Slim Duct Units
Model Name
FDXS09LVJU
FDXS12LVJU
CDXS15LVJU
CDXS18LVJU
CDXS24LVJU
External Static Pressure
"W.G.
0.12
0.12
0.16
0.16
0.16
Airflow-Wet (H/M/L/SL)
CFM
305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297
Airflow-Dry (H/M/L/SL)
CFM
305/280/260/235 305/280/260/235 424/388/353/297 424/388/353/297 424/388/353/297
Sound Pressure - Cooling (H/M/L/SL)
dB(A)
35/33/31/35/33/31/37/35/33/31
37/35/33/31
37/35/33/31
Sound Pressure - Heating (H/M/L/SL)
dB(A)
35/33/31/35/33/31/37/35/33/31
37/35/33/31
37/35/33/31
Liquid (O.D.)
in.
Ø 1/4
Ø 1/4
Ø 1/4
Ø 1/4
Ø 1/4
Piping Connections
Gas (O.D.)
in.
Ø 3/8
Ø 3/8
Ø 1/2
Ø 1/2
Ø 1/2
Condensate Drain
in.
Ø 25/32
Ø 25/32
Ø 25/32
Ø 25/32
Ø 25/32
Dimensions (H x W x D)
in.
7-7/8 x 27-9/16 x 24-7/16
7-7/8x35-7/16x24-7/16
Net Weight
lbs.
47.0
47.0
60.0
60.0
60.0
Indoor Units - FFQ_LVJU 2’x2’Duct Units
Model Name
FFQ09LVJU
FFQ12LVJU
FFQ15LVJU
FFQ18LVJU
Airflow Rate (H/L)
CFM
318/230
353/230
424/283
530/353
dB(A)
35/33/31/35/33/31/37/35/33/31
37/35/33/31
Sound Pressure - Cooling (H/L)
dB(A)
35/33/31/35/33/31/37/35/33/31
37/35/33/31
Sound Pressure - Heating (H/L
Liquid (O.D.)
in.
Ø 1/4
Ø 1/4
Ø 1/4
Ø 1/4
Piping Connections
Gas (O.D.)
in.
Ø 3/8
Ø 3/8
Ø 1/2
Ø 1/2
Condensate Drain (O.D.)
in.
Ø 1-1/32
Ø 1-1/32
Ø 1-1/32
Ø 1-1/32
Dimensions – Unit (H x W x D)
in.
11-1/4 x 22-5/8 x 22-5/8
Dimensions – Deco Panel (H x W x D)
in.
2-1/4 x 27-5/8 x 27-5/8
Net Weight
lbs.
38.5
38.5
38.5
38.5
TIME‐SAVING INSTALLATION AND EASE
Longer Refrigerant Piping
Longer refrigerant piping capabilities offers much more flexibility in the choice of installation positions for the indoor units, and greatly simplifies system layout.
Piping Requirements
Maximum
allowable
length
Allowable Length Details
Between outdoor and BP units
Total piping length
Between BP and indoor units
Total piping length
Piping length between BP and indoor units: 262 ft (80 m) - [Example] f+g+h+i+j+k+l ≤ 262ft
Between BP and indoor unit
1 room length
Piping length between BP and indoor unit ≤ 49 ft (15 m) - [Example] f, g, h, i, j, k, l ≤ 49 ft
Between outdoor and indoor
units
Allowable
height
Difference in height between outdoor and indoor units (H1) ≤ 98 ft (30 m)
Between outdoor and BP units
Difference in
height
Between BP and BP units
Between indoor and indoor units
Minimum allowable length
Piping length between outdoor and BP units ≤ 180 ft (55 m) - [Example] a+b+c+d+e ≤ 180 ft
Difference in height between outdoor and BP units (H2) ≤ 98 ft (30 m)
Difference in height between BP and BP units (H3) ≤ 49 ft (15 m)
Difference in height between indoor and indoor units (H4) ≤ 49 ft (15 m)
Piping length
Pipe length between outdoor unit and first refrigerant branch kit (refnet joint) ≥ 16.4 ft [Example] a ≥ 16.4 ft
Piping length from first refrigerant branch kit (REFNET joint) to indoor unit ≤ 131 ft (40 m)
[Example] unit 6: b+c+k ≤ 131 ft [Example] unit 5: b+e+j ≤ 131 ft [Example] unit 3: d+h ≤ 131 ft
Allowable length after the REFNET branch
Additional refrigerant calculation
Simplified Electrical Wiring
The outdoor unit and BP units operate from separate 208/230V single‐phase power supplies. Indoor units are powered from the BP unit and wired as Daikin’s current 4 wire single split systems reducing the wiring size and easing installation
Space Saving Design
More than 60% in physical space savings
More than 80% in total (including clearances) space savings
12‐5/8”
Installation Space
Daikin RMXS
Traditional Outdoor Unit
35‐1/8”
38‐11/16”
35‐7/16”
System Operation Range
Cooling Operation
23 °FDB – 115 °FDB Ambient Temperature
57 °FWB – 82 °FDB Indoor Room Temperature
Heating Operation
5 °FDB – 60 °FWB Ambient Temperature
50 °FDB – 82 °FDB Indoor Room Temperature
Note: No low ambient option exists with this product line.
WARNINGS:
• Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
• Use only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
• Read the User’s Manual carefully before using this product. The User’s Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.
For any inquiries, contact your local Daikin sales office.
Use of the AHRI Certified™ mark indicates a manufacturer's
participation in the certification program. For verification of
certification for individual products, go to www.ahridirectory.org
© 2013 Daikin Industries, Limited.
Daikin, Daikin AC Absolute Comfort, and its design, VRV, REFNET, Quaternity, Daikin Altherma are trademarks of Daikin Industries, LTD.
www.likin-daikin.com
Distributor or Dealer Information:
Daikin AC (Americas), Inc.
1645 Wallace Drive, Suite 110
Carrollton, TX 75006
www.daikinac.com
866.4DAIKIN
972.245.1510
PF8ZMUSE13-05R
For all equipment installation & application limitations please refer to the specific Engineering Data Books.
Daikin’s products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice
and without incurring any obligations.
Download PDF