Montigo BF36-ST Installation, Operation & Maintenance Manual
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
▼
Scroll to page 2
of
18
fire feature www.montigo.com Installation Operation & Maintenance Manual Check local codes and read all instructions prior to installation. BF36-SS BF36-ST BF-Series SS Gas Fireplace BF52-SS Single-side Shown Warning: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Safety Notice: Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain hot even after the fireplace has been turned off. Safety screens are available and can reduce the risks of severe burns. For Your Safety: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ® C XG0712 US Canadian Heating Products Inc. Langley, BC V4W 4A Warning: What to do if you smell gas • • Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. • Installer: Leave this manual with the appliance. • Consumer: Keep this manual for future reference. Montigo Del Ray Corp. Ferndale, WA 98248 031811 BF36 SS and ST Gas Fireplace fire feature Warning: Read this manual before installing, operating or troubleshooting this appliance. Please retain this owner's manual for future reference. Congratulations Congratulations on selecting a FireFeature Custom gas fireplace, an elegant and well designed gas fireplace built to your specifications. The Firefeature gas fireplace you have selected is designed to provide the utmost in safety, reliability, and engineering standards. As the owner of this new fireplace, you'll want to read and carefully follow all the instructions contained in this Installation, Operations and Maintenance manual. Pay special attention to all cautions, warnings, and Important warnings. This owner's manual should be retained for future reference. We suggest that you keep it with all your other important documents and product manuals. The information contained in this owner's manual, unless noted otherwise, applies to all models, and gas control systems. Your new FireFeature Custom gas fireplace will give you years of durable, reliable use. Welcome to the FireFeature family of gas fireplace products. Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. • Important: Used to address practices not related to personal injury. Table Of Contents Congratulations Installing the BFL52 Designer Beads............................ 14 Safety Alert Key Finishing around the fireplace Introduction................................................................................ 3 Facing............................................................... 15 Installation Mantels and Surrounds.................................... 15 Installing and Framing the Fireplace............................... 4 Operation .........................................................................16 - 17 Installing the Gasline....................................................... 5 Start-up Sequence.................................................16 - 17 Installation Requirements................................... 5 Maintenance . .......................................................................... 18 Electrical Supply................................................. 6 General......................................................................... 18 Installing the Remote Switch.............................. 6 Cleaning........................................................................ 18 Vent Terminations............................................... 6 Troubleshooting............................................................. 18 Venting................................................................ 6 Warranty .................................................................................. 19 Power Vent Control Box.................................................. 7 Appendix Start-Up Sequence schematic........................................ 8 Removing & reinstall the Door........................................ 9 Notes ..................................................................................... 21 Installing the BF36 Logset............................................ 10 Installing the BF52 Logset............................................ 11 Installing the BF60 Logset.....................................12 - 13 Installing the BF84 Logset.....................................14 - 15 Page 2 A State of Massachusetts / Amendment...................... 20 Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Introduction About the BF36-Series Power Vented Fireplaces: Installing The Fireplace The BF36-Series-Gas fireplace is available in Single Sided or See Through To install the fireplace: BF36-SS Natural Gas and Propane, at 110,000 BTU/H (31.90 Kilowatts) Input. The fireplace system is an engineered fireplace system, and will require you to provide the correct vent run and air supply information to the Engineering staff of Montigo. BF36-ST Linear Burner, Natural Gas and Propane, at 115,000 BTU/H (33.35 Kilowatts) Input. Warranty and Installation Information: The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions: Modification of the fireplace and/or components including the vent assembly or glass doors. Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system. Installation other than as instructed in this manual. Consult your local Gas Inspection Branch on installation requirements for factory-built gas fireplaces. Installation & repairs should be done by a qualified contractor. Installations in Canada must conform to the current CAN/CGA B-149.1 and .2 Gas Installation Code and local regulations. This appliance must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. Installations in the USA must conform to local codes, or in the absense of local codes to the National Fuel Gas Code, ANSI Z223.11988. The appliance must be grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987. Within the State of Massachusetts this fireplace must comply with NFPA-54 Chapter 10. Warranty and Installation Information: The Montigo warranty will be voided by, and Montigo disclaims any responsibility for, the following actions: Modification of the fireplace and/or components including vent assembly or glass doors. Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system. Installation other than as instructed in this manual. Consult your local Gas Inspection Branch on installation requirements for factory-built gas fireplaces. Installation & repairs should be done by a qualified contractor. WARNING! After this initial consultation with Montigo we will specify the correct power vent model for your project. The fireplace can be installed on any combustible platform, as there will be no heat transfer to the base of the fireplace Fresh Air Supply: Connect all of the fresh air supply for this fireplace to the lower vent connections assuring no reduction or restriction to the air supply occurs, even due to unexpected circumstances. Please consider automated dampers, particularly on the intake air supply in cold climates. This is especially important when the intake air is introduced from the top down. Cold air has the tendency to settle to the lowest point in the vent system. For extra long air supply runs, Montigo will recommend an increase in vent diameter. When changing the air supply from several incoming air connections to one vent, consult this information with your contact at Montigo. To ensure adequate operation of the vent system ensure the size of the one vent is not less than the total sum of vents that you are connecting to. Flue Gas vent run: The fireplace system may be installed with any certified UL or ULC B-Vent. All the clearances to this B-Vent must be equivalent to the manufacture’s specifications as outlined in the installation/operation manual. The size of this B-vent is specified in the approval process and cannot be reduced unless Montigo has re-evaluated your system. If authorized to reduce your vent size you will be issued new shop drawings reflecting the new vent connection size and specifications. The vent system may be installed vertically or horizontally, to any length, and may have numerous elbows (information of quantity as supplied to Montigo). Montigo will then re-evaluate this information and size the Power Vent to the vent restriction, and compensate for the pressure drop. Power Vent: Montigo manufactures a variety of Power vent modules as large as 5KWatts. The Power vent is commonly placed either horizontally or vertically at the end of the B-Vent run. However, we have an in-line vent module available. This Inline Power vent is for installations where an exterior module isn’t visually attractive, or permitted. Also, In-line Power vents are more complex to install, primarily due to the positive pressure in the vent system after the Power vent module. Therefore this vent run after the Power vent module must be air-tight due too the concern gas by-products may leak from the vent into the structure. All Power vent modules create a negative pressure before the module and leaks in the vent draw air from the building and will not create a safety hazard. When this appliance is installed directly on carpeting, tile or any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance. Part No. XG0712 - 031811 Page 3 BF36 SS and ST Gas Fireplace fire feature Installation Installation: The fireplace may be installed in any location that maintains proper clearances to air conditioning ducts, electrical wiring and plumbing. Safety, as well as efficiency of operation, must be considered when selecting the fireplace location. Try to select a location that does not interfere with room traffic, has adequate ventilation, and offers an accessible pathway for vent installation. Refer to Vent Installation Section for more information. Please refer to the dimensions below and the clearances on the following pages when selecting the location of your fireplace. Clearances: BF36-SS BF-36-ST Sides 3" 3" Back 3" N/A Floor 0" 0" Top 24" 24" Mantel w/Door 24" 12" Mantel w/o Door 12" 6" Dimensions: 9.750 9.750 28.000 28.000 34.020 39.120 44.000 26.060 40.040 39.120 44.000 26.060 4.520 4.520 66.050 66.050 31.120 27.875 35.875 31.120 27.875 35.875 12.000 12.000 11.830 11.830 20.340 20.340 7.125 Figure 1. BF36-Single Side dimensions. Page 4 7.125 Figure 2. BF36-See Through dimensions. Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Installation Framing Single SIded Unit 108” 108” “X” “X” “Y” “W” “Y” “W” Figure 2. Framing dimensions and clearances to combustibles. Figure 2. Framing dimensions and clearances to combustibles. “X1” “X1” “X” “X” “Z” Figure 3. Framing dimensions side view. Part No. XG0712 - 031811 “Z” Figure 3. Framing dimensions side view. W X X1 Y Z BF-36-SS 94 48 73 64 27 BF-36-ST 94 48 73 64 27 Page 5 BF36 SS and ST Gas Fireplace fire feature Installing The Gas Line The gas line must be installed before finishing the BF-SS Fireplace. Natural Gas requires a minimum inlet gas supply pressure of 5.5" W.C. & a manifold pressure of 3.5" W.C. Propane Gas requires a minimum inlet gas supply pressure of 11" W.C. & a manifold pressure of 10" W.C. Provision must also be made for a 1/8" N.P.T. plugged tapping and be accessible for test gauge connection immediately upstream of the gas supply controls to the appliance. The fireplace gas connection and the main operating gas valve is located behind the removable brick panel in the centre of the unit. It only needs to be attached to the gas line with an approved fitting, as required by the applicable installation codes. Gas Line access. Control Cable Connection to Electrical Box Figure 4. Gas line access. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Important: All dimensions, and design specifications are subject to approval upon quotation of fireplace and associated equipment. WARNING! When this appliance is installed directly on carpeting, tile or any combustible material other than wood flooring, it must be installed on a metal or wood panel extending the full width and depth of the appliance. Page 6 Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Installation Installation Of Electrical Supply The BF36 Fireplace is supplied with an external electrical Control Panel pre-wired by the factory. The standard gas control cable is 15 feet between the fireplace and the external panel, additional length is available upon request. The external panel is 16" x 16" x 6" and must be located in an accessible location. The C-View requires 120V electrical supply on a dedicated 15 amp fuse or circuit breaker to the Control Panel. Installations in Canada must be electrically grounded in accordance with CSA C22.1 Canadian Electrical Code Part 1 and/or Local Codes. Installations in the USA must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70-1987. 110V Power Supply Fuse Post Purge Control Vent Terminations Selecting A Termination Location Before installing the termination or venting, check to ensure the planned termination location is acceptable. See figure 10 & 10a below. Vent Installation General Installation Requirements The BF36 fireplace is certified for use with any approved 12" BVent venting components. (Use information below for 'With door' application) 1" clearance to combustibles for vent pipes on all vent runs, or use the clearances specified by the B-Vent manufacturer, whichever is greater. This Power Vent system will depressurize the building at 1800 CFM, and a sufficient air intake system must be installed to avoid any malfuntion of other appliances that rely on room air. This fireplace is a sealed unit and will not effect or alter the building air system. However due to the large amount of air that moves through the fireplace the net gain will be very small. Power Vent Motor Gas Control Wiring Wall Switch Air Proving Switch Fan Speed Control Figure 7. Electrical Supply Installation Requirements (With & Without door) Use only certified B-Vent vent components. (Use of other parts will void the Montigo warranty, and may impede the operation of the fireplace). All joints must be secured as per the instructions provided by the B-Vent manufacturer. The exhaust portion of a vent termination must not be recessed in walls or siding. The electrical panel has three connection boxes on the side of the panel marked: 110 Volt Power Supply, Power Vent Motor, and Gas Control Wiring. Horizontal runs must be supported by a minimum of three supports per 10 feet of venting. First Connect the White, Black, and Green (Ground) wire coming from the power vent motor in the box marked Power Vent Motor. Then connect the cable from the fireplace. Last connect the power supply to the box marked 110 Volt Power Supply. See the diagram on page 7 for the cable installation. Each Horizontal Venting installation may have up to three 90° elbows. Each Vertical Venting installation may have up to four 90° elbows. Two 45° elbows consist of one 90° elbow. Installing The Remote Switch The BF36's two gas valves, located inside the unit and underneath the burner, may be connected to a wall switch or a hand-held remote. The valve operates on a 24V circuit. DO NOT connect the gas valve to an external circuit. The external electrical panel supplied with the fireplace is equipped with a 20 foot low voltage wire, for connecting to a wall switch of your choice, longer lengths are an option. Part No. XG0712 - 031811 Page 7 BF36 SS and ST Gas Fireplace fire feature Installation Power Vent Control Box Power Vent Termination Wiring requirements for Power Vent Installation 12” 12” B-VentDuct, One run for Horizontal or Vertical Installation Required. Power Vent Termination Figure 7b. BF-SS Standard Control Box Figure 7. Typical B-vent configurations. Exterior Power Vent / Wire Routing Installation Diagram Power Vent Termination Combustion Air Supply System Installation Requirements An intake grill will have to be installed with the same size of the total opening as the combined air supply ducts on the unit. Make sure you have calculated the restriction and selected the proper grill size. The BF-SS fireplace is supplied with two or more combustion air duct connection points. Do not reduce the size of the air supply system, or restrict the air supply in any way. On any combustion air supply run longer than 10 feet the duct should be increased in size to prevent a restriction. A vacuum safety switch, located under the burners, will monitor the combustion air supply pressure and will prevent the burner from igniting, or continuing to burn if the pressure is negative, past 0.08WC. For extremely long air supply runs the combustion air supply will have to be power assisted. One Control Cable Installation required for either Horizontal or Vertical Termination. Power Vent Termination 16”x 16”x 4” Deep Elect. Control Box 20’ Foot, 10-Conductor Cable to Fireplace, (Standard) 110 VAC 15A Supply Current From Dist. Panel To Control Box From Control Box Figure 7a. BF-SS Control Box / Power Vent Wire Routing Diagram) Page 8 Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Installation Startup Sequence: 1. Ensure that there is continuous power to the Post Purge Control Module. Supply chamber in the firebox, and it is normally closed unless inadequate combustion air supply will open the switch. 6. The Post Purge Control will now power up terminal 1 and 2 with 2. Ignition is initiated by turning on wall switch, which will close relay R1 activating Smart Valve No.1 as well as terminal 3 and 4 terminal 5 and 6. with relay R2 activating Smart Valve No.2. 3. The Post Purge Control will start the Power Vent Motor at the 7. The Smart Valve system will light the pilotand by proving the pres- speed set speed on Speed Control. ence of a pilot flame it will fire up the burners. After the third failure 4. When adequate air flow is established the Air Proving switch will to establish a pilot the valve will lock out. close terminal 9 and 10 8. To reset the system turn the wall switch 'off' and then back 'on'. 5. Terminal 7 and 8 is the vacuum switch inside the Combustion Air 110V Power Supply 6 Amp 110V Fuse PostPurge Purge Control Post Control 110V Motor R G B B R R W To Fireplace W Bk Bk W W Bk G Bk 110V 110V 24V 24V Motor Speed Control R2 R1 G Valve 1 Part No. XG0712 - 031811 Red Brn Red Red Pk Valve 2 Wall Switch Jumper Org Blu Blk / Wht Blu LVT Denotes Low Voltage Denotes Line Voltage Wall Switch Wht / Blk Legend Yel First Burner: 1,2 Black-White Second Burner: 3,4 Blue-Yellow Wall Switch: 6,7 Black-White Air Priority Switch: 9,10 Orange-Red Green is Ground Relay Blk / Yel To Wall Switch Relay LVT B Yel O R Blu / Yel P Yel Y W Bk Y Blk / Wht Bk W B Y Yel Y Wht / Blk Y Air Proving Switch Page 9 BF36 SS and ST Gas Fireplace fire feature Installation Removing and Installing the Door Removing the door: The BF-SS Door-Window outer trim is held in place by magnets, and the Door-window frame are held in place by fine-thread 10-24 screws. Follow the process below to remove, or install the items described. installing the door: Install the door in reverse order as shown in Steps 1 through 4. Important: when re-installing screws into their original location, ALWAYS hand tighten with screwdriver to ensure proper tension on all screws. Figure 14. The Fireplace as it is received from Montigo. Figure 15. (Step 2) Remove the Door-window trim by grasping the metal firmly and pull it free it from the frame. Note: Hold it as shown in Step 2 to release the hold of the magnets. Figure 8a. Step 2. (removal of Trim) Figure 8. Step 1. (Door Trim ) WARNING! Do not attempt to clean glass when hot. Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. Do not operate this fireplace without the glass door, or with a broken glass door. Figure 8b. Step 3 (Removal of Frame) Door Figure 8c. (Completed Removal) Cautions: Figure 16. (Step 3) Remove the Door-window assembly by turning the 10-24 screws counterclockwise. Note: Have someone hold the doorwindow assembly in place until all screws are removed. Then grab the assembly from either end lifting it away from the fireplace. Place it in a safe location to store or clean. Fireplace gas control must be in the “OFF” position and pilot Figure 17. (Step 4) Removal is complete. Proceed with service or cleaning. Doors and logs can get very hot. Handle only when cool. Page 10 and main burners extinguished when cleaning appliance with a vacuum. Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Installation Installing the Log set: The BF36 is supplied with a seven piece ceramic fibre logset. Unpack the logs and handle them very carefully and follow directions below. Step 5. P lace one of the shortest end logs in the grove of one of the middle logs., see figure 27c, of the logs placed in step 4, see figure 27d. Step 1. R emove the glass door as described in the previous Instructions. Step 2. P lace the longest bottom 2 logs length wise on the log grate, as shown in figure27a. Ensure the charcoal colour is faces down, the indents facing up and opposite each other. Indents are for positioning the next log, see figure 27b. Figure 27d. smallest side log.. Step 6. Place the last log, as shown in figure 27e, in the groove of the of the logs placed in step 4, see figure 27c Figure 27a. Bottom Rear Log, (Log A). Step 3. Place the second longest centre log, on top, in the grooves of the first two logs placed in Step 2, see figure27a. Ensure that the charcoal colour is facing down and grooves facing up, see Figure 27b. Figure 27e. Last log. Once complete your logset will look like shown in figure 27f Figure 27b. Centre log placement Step 4. Place the two medium length logs in the groves of the centre log placed in the previous Step. See figure 27b. Ensure the charcoal colour is facing down and groves are facing up. The groves are for placement of the next log, see figure 27d Figure 27f. Completed Logset. NOTICE If logs are not placed properly, excessive sooting will result. Figure 27c. Middle centre logs Part No. XG0712 - 031811 XW2044 Page 11 BF36 SS and ST Gas Fireplace fire feature Installation Fireplace Facing (Without Door) When selecting the finish material for your fireplace, it is important to remember the following: The face of the fireplace may be painted to match the room decor, provided you use a heat-resistant paint. Decorative facing must not extend past the fireplace opening at all, because it will interfere with the access to retainers for removal of glass door. BF36-SS BF36-ST Figure 14. Combustible mantles and facings (W/O Door). Figure 15. Combustible surrounds. Fireplace Facing (With Door) When selecting the finish material for your fireplace, it is important to remember the following: The face of the fireplace may be painted to match the room decor, provided you use a heat-resistant paint. Decorative facing must not extend past the fireplace opening at all, because it will interfere with the access to retainers for removal of glass door. BF36-SS BF36-ST Figure 14a. Combustible mantles and facings (With Door). Page 12 Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Operation - Model BF-SS with Honeywell Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. What To Do If You Smell Gas: ■ Do not try to light any appliance. ■ Do not touch any electrical switch; do not use any phone in your building. ■ Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. ■ If you cannot reach your gas supplier, call the Fire Department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it, call a qualified service technician. Force or attempt to repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system, and any gas control which has been under water. Lighting Instructions: 1. STOP! Read the safety information above on this label. 2. Remove the lower Horizontal access panel. 8. If the fireplace does not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier. 3. Turn switch on the gas control to OFF". 4. Wait 5 minutes to clear out any gas. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step. 5. Turn switch on the gas control to "ON". NOTE: This unit is equipped with an ignition system that lights the pilot burner automatically. Do not attempt to light the pilot by hand. 6. Turn on wall switch. 7. Replace the lower Horizontal access panel. Gas Inlet Gas Control Switch Shown in "On" Position To Turn Off Gas To Appliance: 1. Turn off remote switch. 3. Turn the switch on the gas control to "Off". 2. Remove the lower Horizontal access panel.. 4. Replace the lower Horizontal access panel. Part No. XG0712 - 031811 Page 13 BF36 SS and ST Gas Fireplace fire feature Maintenance Gas Control Valve WARNING! Do not attempt to clean glass when hot. Bk L42DF-ST W Do not clean glass with abrasive materials as any glass etching may cause premature glass failure. R Connector GasC ontrol Do not operate this fireplace without the glass door, or with a broken glass door. General Control (SV9501M) Honeywell Gas Have the fireplace installation inspected yearly, including a visual check of the vent system, the burner and the pilot flame. For your convenience a 1/8" manifold pressure tap is supplied on the gas valve for a test gauge connection. See Figure 17. For Natural Gas this appliance requires a minimum inlet pressure of 5.5" W.C. and a manifold pressure of 3.5" W.C. For Propane Gas this appliance requires a minimum inlet pressure of 11" W.C. and a manifold pressure of 10" W.C. Always keep the fireplace area clear and free of combustible materials, as well as gasoline and other flammable vapours and liquids. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Cleaning When the fireplace is first activated, there may be some smoking and a visible film may be left on the glass. This is a normal condition, and is the result of burning of protective coatings on new metal. Glass must be cleaned periodically to remove any film (which is a normal biproduct of combustion) which may be visible. Film can easily be removed by removing the door, as shown on page 8. Handle the door carefully, and clean it with non-abrasive glass cleaners. One of the most effective products is Kel Kem. Harness Connector Pilot Electrical Pilot Assembly Honeywell (Q3450) Figure 16. Honeywell SV9501 gas valve. Troubleshooting HONEYWELL SV9500 /9600 Troublshooting Sequence NOTE: Before Troubleshooting, Familiarize Yourself With START The Startup And Checkout Procedure. SV9500 / SV9600 is powered (24VAC nominal) NO Use a vacuum cleaner or whisk broom to keep the control compartment, burner, and firebox free from dust and lint. Turn gas on. Pilot Burner Lights? If your fireplace still does not operate correctly, consult your dealer or the manufacturer. All service and repairs should be performed by a qualified agency. All spare parts, optional fans, and optional trim finishes are available from your local dealer or the manufacturer. Page 14 YES NO YES SYSTEM OK Unplug Pilot Burner Cable, Measure Voltage at SV9500/SV9600 HSI Terminals (24VAC Nominal, see INSET) NO Replace SV9500/ SV9600 Replace Igniter / Flame Rod Assembly Replace SV9500/SV9600 NO Measure Volume to SV9500 / SV9600 Voltage must be at least 19.5 VAC NO YES YES Main Valve opens? HSI - Line voltage power Terminals - Low voltage transformer - Limit Controller - Thermostat - Wiring - Air proving switch on combustion air blower system -Vent damper (if used) is open and end switch made YES Igniter warms up and glows red. Pilot Valve opens. Logs may be cleaned periodically with a vacuum to remove soot or other contaminates. NO YES Silicone seals on inner door during initial firing will "off gas", leaving a visual deposit of a white substance on combustion chamber walls. This can easily be removed using normal household products. INSET CHECK: - Turn Gas Supply Off - Set thermostat to call for heat Check Transformer Line Volt Supply Replace Igniter / Flame Rod Assembly NO Replace Igniter / Flame Rod Assembly and retain. Restart troubleshooting Sequence. Does main valve open? YES NO Replace SV9500 / SV9600. Save old Igniter/ Flame Rod Assembly for service. Discard old Igniter / Flame Rod Assembly Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Warranty The Warranty The Companies warrants the Montigo Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the Montigo, there is a ten-year warranty on the firebox and its components, a five-year warranty on the main burner, and a one-year warranty on the pilot burner, gas control valve and fibre logs. Glass, plated/painted finishes, and refractory lining are exempt. Remedy And Exclusions The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Companies. This Warranty only covers Montigo Gas Appliances installed in the United States or Canada. If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Companies right of investigation outlined below). The Companies will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Companies at no charge, and will also pay for reasonable labour costs incurred in replacing or repairing components. If repair or replacement is not commercially practical, The Companies will, at its option, refund the purchase price of the Montigo Gas Appliance. This Warranty covers only parts and labour as provided above. In no case shall The Companies be responsible for materials, components, or construction which are not manufactured or supplied by The Companies, or for the labour necessary to install, repair or remove such materials, components or construction. All replacement or repair components will be shipped F.O.B. the nearest The Companies factory. Qualifications To The Warranty The Gas Appliance Warranty outlined above is further subject to the following qualifications: (1) The Gas Appliance must be installed in accordance with The Companies installation instructions and local building codes. The Warranty on this Montigo Gas Appliance covers only the component parts manufactured by The Companies. The use of components manufactured by others with this Montigo Gas Appliance could create serious safety hazards, may result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes. This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies (2) The Montigo Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such as wood, coal or any other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard. Limitations On Liability It is expressly agreed and understood that The Companies sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no event shall The Companies be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is discovered before or after replacement or repair, and whether or not such damage is caused by The Companies negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you. Investigation Of Claims Against Warranty The Companies reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement. The Companies Are Not Responsible For Work Done Without Written Consent The Companies shall in no event be responsible for any warranty work done without first obtaining The Companies written consent. Dealers Have No Authority To Alter This Warranty The Companies employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above. How To Register A Claim Against Warranty In order for any claim under this Warranty to be valid, The Companies must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible after the defect is discovered. Claims against this Warranty in writing should include the date of installation, and a description of the defect. Other Rights This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. NOTE: The Companies as stated above refer to - Canadian Heating Products Inc. and/or Montigo Del Ray Corp. Canadian Heating Products Inc. and/or Montigo DelRay Corp. reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Part No. XG0712 - 031811 Page 15 BF36 SS and ST Gas Fireplace fire feature Appendix B - State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft. (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. (b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: 1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and 2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer: 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. (3) After NFPA-54 section 10.10.4.2 add a new section 10.10.4.3 as follows: When more than four gas appliances are to be vented through a common gas vent or common horizontal vent manifold, a plan of the proposed vent installation shall be submitted to the Inspector and the serving gas supplier for review and approval. Extraction from: Massachusets Rules and Regulations 5.00: Amendments To 2002 Edition Of ANSI Z223.1-NFPA-54 Page 16 Part No. XG0712 - 031811 BF36-SS and ST Gas Fireplace fire feature Notes Part No. XG0712 - 031811 Page 17 fire feature XG0712 - 031811 Canadian Heating Products Inc. Langley, BC V4W 4A1 Montigo Del Ray Corp. Ferndale, WA 98248
advertisement