Boiling Water Dispensers 283 Centrifugal Fans 257 Commercial

HVAC
Boiling Water Dispensers
Centrifugal Fans
Commercial Fans
Continuous Running Fans
Domestic Fans
Easy Fit Electric Showers
Economy 7 Controllers/
Immersion Heater Controllers
Electric Radiators
Electric Towel Rails
Energy Efficient Hand Dryers
Energy Efficient Storage Heaters
Frost Protection Heaters
Hand Dryers
Immersion Heater Controllers
Installed Electric Heating
Instantaneous Water Heaters
Mechanical Extract Ventilation (MEV)
Oil Filled Heaters & Bathroom Heaters
Panel Heaters
Plinth, Overdoor & Commercial Heaters
Portable Heaters
Room Thermostats/Digital Programmers
Quiet Fans
Storage Heaters
Timeswitches
Tubular Heaters
Unvented Water Heaters/Flat Back Cisterns
Vented Water Heaters
Ventilation Accessories
283
257
260
256
258 - 259
279
277
269
275
263 - 264
267
274
265
277 - 278
266
280
255
272
270
273
271
274
282
281
261 - 262
276
256
268
278
What Type of Ventilation Do I Need?
New Build
New Build/Refurb?
Can a whole house ventilation system be accommodated, including associated ductwork?
YES
Does the property have an air tightness of less than 5M³h/M²?
NO
YES
Continuous running extract fans
YES
NO
MVHR
Continuous multiple room balanced ventilation with heat recovery
MEV
Continuous multiple room extract ventilation
See page
255
Refurb
Is energy efficiency important?
Continuous running
axial fans
Suitable for any room providing silent & energy efficient ventilation
See page
256
Continuous running
centrifugal fans
Energy efficient, near silent fans where greater pressure is needed i.e. for moving air larger distances
(up to 6M duct)
See page
257
100mm or 150mm
Axial fans
For moving air over short distances i.e. through a wall/window
(max 1.5M duct)
See page
258
NO
Intermittent extract fans
Centrifugal fans
Where greater pressure is needed for moving air larger distances i.e.
(up to 6M duct)
See page
257
In-line fans
Where the fan can be concealed & situated within the ducting run in a ceiling void
See page
259
Legislation Summary
When selecting ventilation you can come across many terms and expressions used to promote certain products and systems over others in relation to legislative compliance. It is often not clear what is needed or why and so the aim here is to explain and simplify the most common terms used when ventilation is being specified.
Approved Document F
Also known as Part F or ADF. Part F is the legislation that outlines the ventilation requirements for both new build and existing dwellings. If a product is described as Part F compliant then it meets the criteria set out in this legislation.
Approved Document L
Also known as Part L or ADL. This deals with the conservation of fuel and power - basically energy efficiency. Part L was updated in
2013 and stated energy efficiency targets for houses had to improve by 8%. Ventilation has to comply with a maximum energy use called Specific Fan Power and these are set according to the type of ventilation being used.
Intermittent Extract Ventilation - no higher than 0.5 W/l/s
Continuous Extract Ventilation - no higher than 0.7 W/l/s
Continuous Supply Ventilation - no higher than 0.5 W/l/s
MVHR - no higher than 1.5 W/l/s
SAP
The Government’s Standard Assessment Procedure (SAP) is used for assessing the energy performance of dwellings and the associated running costs and also CO² emissions. The calculation is based on the energy balance (energy running costs vs overall energy efficiency) taking into account a range of factors that contribute to energy efficiency - ventilation is one of these factors.
How do all these things tie together and affect ventilation?
In its simplest form what is being outlined is:
• New builds and refurbs now have to meet various energy efficiency criteria as well as minimum standards of ventilation as laid out by Government legislation (Part L & Part F respectively).
• The ventilation used can have a beneficial effect on your SAP rating and these are listed in the National Calculation Database.
254
|
Mechanical Extract Ventilation (MEV)
MEV
Whole house Mechanical Extract Ventilation (MEV) provides simultaneous ventilation of separate wet areas, kitchens and utility rooms in a house or flat, gathering wet polluted air and discharging it into the atmosphere.
How Does It Work?
• Unit is centrally located - normally in a loft or a cupboard.
• Extract vents are connected to the central unit using ducting.
• Air is simultaneously extracted from wet rooms - bathrooms, kitchens, en-suites, utilty rooms - up to
5 rooms simultaneously.
Usage
• Primarily used in domestic new build applications due to the need to run long ducting runs, although suitable for all types of domestic dwellings.
• Within the building regulations airtight houses are considered to be those with leakage less than 5m³ per hour per square metre of external envelope.
New build houses with more than this would benefit from MEV.
User Friendly Installation
• Can be wall, ceiling or loft mounted for convenience.
• Easy commissioning - each spigot has an auto air volume regulator which controls the air volume pressure regardless of duct length.
• Unit can be controlled via remote switch enabling the user to select one of three fan speeds depending on their particular requirements.
Benefits
• Energy efficiency - Continuously runs at a very low rate and uses considerably less energy than having intermittent extractor fans in all the wet rooms.
• Near silent running - Because they extract continuously, they can do so at very low levels and with the unit sited remotely, they are extremely quiet.
Kit Contents
The NL8002 MEV unit includes the following accessories:
Spigots - room extracts
80mm inlets
80mm spigot covers
125mm inlet
125mm spigot cover
Qty
4
2
1
1
Spigots - exhaust to atmosphere
125mm inlet
Qty
1
• Extract from up to 5 wet rooms simultaneously.
• Eliminates cross contamination due to continuous operation.
• Low noise levels.
• 3 speed settings.
Order Code
1052025552
Model No.
NL8002
Description
Whole House Ventilation Unit
Performance Extract
M³/h
Extract
L/S performance performance Watts dB(A)
Low
Medium
High
240
362
500
67
110
139
24
42
48
37
43
48
Dimensions (mm)
H x L x D
420 x 240 x 425
Accessories for NL8002
Order Code Model No.
1050371030 NL80028
1050371031 NL80029
1050371032 NL80030
1050371033 NL80031
1050371029 NL80027
1050371034 NL80032
Description
Flexible Ducting
Flexible Ducting
Internal Grille
Wall Kit*
Flexible PVC Ducting
Worm Drive Hose Clip
Diameter
(mm)
80
80
80
125
125
60-125
Length (M)
-
-
6
15
6
-
*NL80031 125mm wall kit comprises of 1 x white grille and telescopic tube - 250mm extending to 450mm
For additional rigid & flexible ducting see page 261-262
2 YR
NL8002
NL80028
NL80031
HVAC |
255
Continuous Running/Quiet Fans
Follow these simple instructions for any Newlec continuous running axial or centrifugal filterless fan:
1. Install or retrofit any existing fan.
2. Set the trickle speed to 6l/s (suitable for bathrooms and ensuites) or 9l/s (suitable for kitchens and utility rooms).
Then enjoy all these benefits:
Virtually Silent Running
As low as 11dB(A).
Energy Efficiency
One of the most efficient fans available
and is designed to work within the homes natural heat loss.
No unnecessary heat is lost from the property.
Health Benefits
Reduces condensation, improves indoor air quality and helps prevent mould and damp.
Flexibility
Powerful performance and discreet, slimline styling make it suitable for any room in the house.
4" (100mm) Continuous Running Axial Fans
Virtually silent operation
• Single fan for use in all applications - suitable for any room in the house.
• Continuous running extract fan - 6l/s or 9l/s trickle selectable on installation - boost at 15l/s.
• Slimline flat front for discreet styling and also reduces dust and dirt build up.
• Reduces condensation and improves air quality.
• Designed to work within the homes natural heat loss.
5 YR
Order Code Model
No.
1051058542 NLSAFT
Size
(mm)
100
1051058543 NLSAFTH 100
Extract Rate - l/s
Low
Trickle
6
6
High
Trickle
9
9
Boost
15
15
Power Consumption (W) Sound Level (dB(A)@3M)
Low
Trickle
2
2
High
Trickle
3
3
Boost
4.7
4.7
Low
Trickle
11
11
High
Trickle
16
16
Boost
25
25
Pullcord
✔
Control Options
Timer
✔
✔
Humidistat
✔
4" (100mm) Quiet Fans
60%
quieter
than standard intermittent fans
One of the quietest intermittent fans available on the market today.
• Over 60% quieter than standard intermittent fans - only 27dB(A).
• Low energy - only 4.8W.
• Part F and Part L compliant.
• Wall or ceiling mountable.
• Slimline, discreet design with a depth of only 22mm.
2 YR
Order Code
1051058546
1051058547
Model No.
NLQF
NLQFT
Size
(mm)
100
100
Extract Rate l/s
21
21
Power
Consumption (W)
4.8
4.8
Sound Level dB(A)@3M
27
27
Control Options
Backdraught
Shutters
✔
✔
Timer
✔
256
|
4" (100mm) Continuous Running Centrifugal Filterless Fans
• A filterless centrifugal fan requiring no maintenance schedule.
• Suitable for ducted applications where higher pressures are required.
• Self-cleaning centrifugal impellor.
• SELV version available - suitable for bathroom zone 1 areas containing a fixed bath or shower.
• Slimline profile compared to similar equivalent fans - only 90mm deep or can be flush mounted with a depth of only 17mm.
3 YR
Filterless fan
no maintenance required
Centrifugal Fans
Order Code Model
No.
1051058544 NLSCF
Size
(mm)
100
1051058545 NLSCFSELV 100
Extract Rate - l/s
Low
Trickle
8
8
High
Trickle
13
13
Boost
25
25
Power Consumption (W) Sound Level (dB(A)@3M)
Low
Trickle
1.5
1.5
High
Trickle
2.5
2.5
Boost
8
8
Low
Trickle
11
11
High
Trickle
16
16
Boost
36
36
Pullcord
✔
✔
Control Options
Timer
✔
✔
Humidistat
✔
✔
SELV
✔
4" (100mm) Centrifugal Fans
With a specific fan power (SFP) of only 0.47, the Newlec centrifugal fan fully complies with both current Part F and Part L legislation.
• Can be ceiling or wall mounted.
• Can be flush of surface mounted.
• Adjustable rear or side spigot for ease of installation.
• Backdraught shutters - prevents incoming draughts and heat escaping when the fan is not in use.
2 YR
NL882N
Order Code
1051011034
1051011035
Model No.
NL882N
NL882TN
Size
(mm)
100
100
Extract Rate l/s
20.8
20.8
Power Consumption
Wattage
12.4
12.4
Sound Level dB(A) @ 3m
36
36
Backdraught
Shutters
✔
✔
Pull
Cord
Control Options
Timer Humidistat
✔
SELV
SFP
0.47
HVAC |
257
4" & 6" Domestic Fans
4" (100mm) intermittent extract fans are generally used for bathrooms, ensuites and toilets, with 6" (150mm) being used for kitchens and utilities where a higher rate of extraction is required. They operate most efficiently when wall or ceiling mounted and extract polluted air directly out of the property i.e. no extra ducting is required. The Newlec range of intermittent extract fans can be operated in one of four ways depending on the model selected.
No Additional Fan Controls
• Fan switches on or off remotely through light switch or other remote switch.
Timer
• Timers will continue to run for a predetermined amount of time
- usually between 2 and 20 minutes - once the light has been switched off.
Pull Cord
• Allows the fan to be operated manually rather than being set to turn on when the light switch is turned on.
Humidistat
• This is a built-in adjustable sensor that will switch the fan on/off automatically when the humidity in the room reaches a certain level.
Newlec fans come with a choice of shutter options dependent on the model:
No Shutters
• Low cost on intermittent fans.
• Continuous running fans.
• In-line fans.
Backdraught Shutters
• Are plastic hinged flaps (also known as butterfly shutters) fitted on to the discharge of extractor fans which open when air is being extracted but do not allow air from the outside to travel back in to the property via the fan when not in operation.
Automatic Shutters
• These are thermo-activated internal shutters behind the interior grille of the fan which open and close silently completely sealing the unit when not in use to prevent any draughts, noise ingress or heat loss.
4" (100mm) Standard Fans
• Ideal for bathrooms, ensuites and toilets.
• Can be wall or ceiling mounted.
• High quality ABS mouldings.
2 YR
NL880
• SELV version available - suitable for zone 1 areas containing a bath or a shower.
• CE marked and BEAB approved.
Standard 4
" Fans - No Shutters
Order Code Model
No.
1000009100 NL880
1000009101 NL880T
1000009103 NL880H
Size
(mm)
100
100
100
Extract
Rate l/s
24
24
24
Power
Consumption
Wattage
16
16
Sound
Level dB(A)@3m
32
32
16 32
Shutters
Control Options
Pull
Cord
Timer
✔
Humidistat SELV
✔ ✔
Standard 4
" Fans - Automatic Shutters
Order Code Model
No.
1050151418 NL880PS
1050151416 NL880TS
Size
(mm)
100
100
1050151417 NL880HS 100
1051058548 NL880SELV 100
Extract
Rate l/s
24
24
24
24
Power
Consumption
Sound
Level
Wattage dB(A)@3m
20
20
32
32
20
20
32
32
Automatic
Shutters
✔
✔
Control Options
Pull
Cord
Timer Humidistat
✔
✔
SELV
✔ ✔
✔
✔
✔ ✔
6" (150mm) Standard Fans
• Ideal for kitchens and utilities where a higher rate of extraction is required.
• High quality ABS moulding.
• SELV version available - suitable for zone 1 areas containing a bath or shower.
2 YR
• Suitable for panel, wall or ceiling mounting (pull cord models should not be mounted on the ceiling).
• CE marked and GS approved.
NL883
Standard 6
" Fans
Order Code Model
No.
1000009108 NL883
1000009109 NL883S
Size
(mm)
150
150
1050151419 NL883TS 150
1000009537 NL883HS 150
Extract
Rate l/s
68
68
68
68
Power
Consumption
Wattage
25
30
30
30
Sound
Level dB(A)@3m
45
45
45
45
Automatic
Shutters
✔
✔
✔
Control Options
Pull
Cord
Timer
✔
✔
Humidistat
✔
258
|
4" Fans
4" (100mm) Low Profile Fans
Designed to be more aesthetically pleasing, the Newlec range of low profile fans have a slim 22mm grille yet lose nothing in terms of performance or versatility.
• Can be wall or ceiling mounted for installation convenience.
• Backdraught shutters to prevent draughts.
• SELV version available - suitable for Zone 1 areas containing a fixed bath or shower.
2 YR
Order Code
1051058550
1051058552
1051058553
Model No.
NLLPF100TA
NLLPF100LVTA
NLLPF100LVTHA
Size
(mm)
100
100
100
Extract Rate l/s
25
25
25
Power
Consumption
(W)
14
14
14
Sound Level dB(A)@3M
38
38
38
Backdraught
Shutters
✔
✔
✔
Control Options
Pullcord Timer
✔
✔
✔
Humidistat
✔
SELV
✔
✔
Finish
White
White
White
4" (100mm) Shower Fan Kits
Ideal for use within shower enclosures, wet areas and en-suites, the Newlec shower fan kits are easy to install and eliminate the risks of electric shocks as the fan is situated remotely. Available with an overrun timer or an overrun timer with light.
Kits include:
• Fan.
• 1.5m flexible ducting.
• Internal and external grilles.
• Screws, plugs and cable ties.
• Light option includes 12V transformer and light kit.
2 YR
NLFLT3
SFP
0.43
4
" Shower Fan Kits
Order Code
1051011037
1051011038
Model No.
NL881TN
NLFLT3
Size
(mm)
100
100
Extract Rate l/s
23.6
23.6
Power Consumption
Wattage
15
15
Sound Level dB(A) @ 3m
41
41
Shutters
4" (100mm) In-Line Mixed Flow Fans
The Newlec In-Line mixed flow fans offer two and a half times the pressure of a conventional axial fan whilst also being dimensionally compact. This makes them ideal for solving ventilation problems for ducted systems.
• Energy efficient and Part L compliant - SFP of only 0.4 at low speed and 0.37 at high speed.
• High quality ball bearing long life motors.
• Ideal for ducted applications.
• IPX4 rated.
2 YR
NL8000
Order Code Model No.
1052025550 NL8000
1052025551 NL8001
Size
(mm)
100
100
Extract Rate l/s
High speed/low speed
69/52
69/52
Power
Consumption
Wattage
25
25
Sound Level dB(A)
@ 3m High speed/ low speed
24/20
24/20
Control Options
Timer
✔
Control Options
Timer
✔
✔
Light
✔
SFP
0.4
LOW SPEED
SFP
0.37
HIGH SPEED
HVAC |
259
Commercial Fans
In order to determine the right size fan for the commercial application required, you need to calculate the correct fan performance (M³/hr). To do this calculate the room volume in cubic metres, i.e. length x breadth x height, and then multiply by the number of air changes required. For example a canteen is 10M wide by 6M long and 3M high, the canteen is 180M³ (10 x 6 x 3) and requires 8 air changes - 180 x 8 = 1440 M³/hr extract performance required. Assuming the fan is wall mounted, then select a 12" wall fan.
Bathroom & Shower Rooms
Bedrooms
Cafes
Canteens
Cellars
Changing Rooms with Showers
Conference Rooms
Garages
Commercial Fans
3
2
10
8
3
15
8
6
Air Changes Required
Hairdressing Salons
Halls & Landings
Hospital Rooms
Laundries & Launderettes
Living & Other Domestic Rooms
Meeting Rooms
Offices
Restaurants & Bars
10
3
4
10
3
6
4
6
School Rooms
Shops
Sports Facilities
Store Room
Toilets - Domestic
Toilets - Public
Utility Rooms
Workshops
6
3
8
2
3
10
15
6
NLCOMF12A
• Suitable for panel/wall mounting or window mounting with appropriate window accessory kit.
• External 2 speed reversible on/off controller available (NLCOMFC).
• Motor fitted with thermal overload protection.
• CE marked in accordance with all the relevant EEC standards.
• IP44 rated.
2 YR
NLCOMFC
Order Code
1050151361
1050151363
1050151367
1050151364
1050151368
1050151369
Model No.
NLCOMF9F
NLCOMF9A
NLCOMF12A
NLWK9
NLWK12
NLCOMFC
Description
Commercial Fan with Fixed Grille
Commercial Fan with Automatic Shutters
Commercial Fan with Automatic Shutters
Window Kit
Window Kit
2 Speed Reversible Controller
Size
(")
9
9
12
9
12
Extract Rate
(M³/hr)
1015
1015
1630
Sound Level dB(A) @ 3M
52
52
54
Control Options
Auto Shutter
✔
✔
NEW
DALI OCCUPANCY SYSTEM
SEE PAGES 49 & 50
Quick and easy set up DALI lighting control systems
260
|
Flat Channel and Accessories
NLFC2M NLFCCLIP NLFCCON
Ventilation Accessories
NLFCEBF
NLFCEBM NLFCHB
NLFCVB
NL8012
NL8016
NLFCAB
110mm x 54mm Accessories
Order Code Model No.
1050325791 NLFC2M
1050325792 NLFCCLIP
1050325793 NLFCCON
1050325794 NLFCEBF
1050325795 NLFCEBM
1050325796 NLFCHB
1050325797 NLFCVB
1050325798 NLFCAD
Description
2M Flat Channel
Fixing Clip
Flat Connector
90˚ Elbow Female
90˚ Elbow Male
90˚ Horizontal Bend
90˚ Vertical Bend
Round to Horizontal
1 YR
Diameter
(mm)
-
-
-
100
100
-
-
100
204mm x 60mm Accessories
Order Code Model No.
1052025537 NL8010
1052025540 NL8013
1052025541 NL8014
1052025542 NL8015
1052025538 NL8011
1052025539 NL8012
1052025543 NL8016
Description
1.5M Flat Channel
Fixing Clip
Flat Connector
90˚ Elbow Male
90˚ Horizontal Bend
90˚ Vertical Bend
Round to Horizontal
Diameter
(mm)
-
-
-
100
-
-
125
1 YR
HVAC |
261
Ventilation Accessories
PVC Flexible Ducting
NL870
Exterior Wall Grille
NL877B
NL871
Gravity Wall Grille
NL883GB
Wall Venting Kit
NL873
Window Venting Kit
NL880G
1 YR
Order Code Model No.
1000009110 NL870
1050325789 NL872
1000009535 NL883D
Length
(M)
3
15
3
Diameter
4" (100mm)
4" (100mm)
6" (150mm)
1 YR
Order Code Model No.
1000009111 NL871
1050151547 NL871B
1000009536 NL877
1000009599 NL877B
Colour
White
Brown
White
Brown
Diameter
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
1 YR
Order Code Model No.
1000009533 NL880G
1000009600 NL880GB
1000009534 NL883G
1000009601 NL883GB
Colour
White
Brown
White
Brown
Diameter
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
1 YR
Order Code Model No.
1000009113 NL873
1050363045 NL873B
1000009114 NL874
1050363046 NL874B
Colour
White
Brown
White
Brown
Diameter
4" (100mm)
4" (100mm)
6" (150mm)
6" (150mm)
1 YR
Order Code Model No.
1000009115 NL875
1000009116 NL876
Diameter
4" (100mm)
6" (150mm)
NL875
262
|
Energy Efficient Hand Dryers
The Enhanced Capital Allowance (ECA) scheme defines energy efficient dryers as those that use less than 6.9kWh of electricity per 1000 standard cycles. All Newlec energy efficient dryers meet this criteria with the 1.6kW fast dry hand dryer ranges being on the Energy Technology List (ETL) meaning they are eligible for the governments ECA scheme.
The ECA scheme provides businesses with enhanced tax relief for investments in equipment that meets their published energy saving criteria thereby providing an incentive to invest in energy efficient equipment (see etl.decc.gov.uk for further details).
Choosing the most energy efficient dryer for your needs
Based on an assumption of electricity costs of £0.095 per kW/Hr, with the dryer being used for 200 dries a day for 300 days a year. The cost of using paper towels is based on
4000 paper towels.
Paper
Towels
2.4kW Hand &
Face Dryer
1.6kW Energy
Efficient Dryer
1.0kW Energy
Efficient Dryer
Cross Wind
Hand Dryer
Energy Cost per Year
£510 £106.40
£32.40
£19.00
£20.58
kW per hour per
1000 drying cycles
N/A 16.7
5.4
3.3
3.6
ECA Eligible
N/A NO YES NO NO
1.6kW Energy Efficient Fast Dry Hand Dryers
• Automatic operation - reduces risk of spreading germs.
• Motor thermal protection auto resetting at 105°C.
• IPX1 rated.
• Class 1 Electrical Safety.
2 YR
Energy Saving Features
• 12-14 second dry time - uses less energy per dry.
• Low energy option on installation - from 1.6kW down to 1.2kW for even greater energy savings.
• Blue LED gives visible indication of drying zone ensuring hands are always in warm air stream.
• Eligible for ECA funding.
Save over
65% energy
vs conventional
2.4kW dryers
NL9000
NL9001
NL9002
Order Code
1050363164
1050363165
1050363166
Model No.
NL9000
NL9001
NL9002
Noise Level
(dBA) at 1M
78
78
78
Output
(kW)
1.6 - 1.2
1.6 - 1.2
1.6 - 1.2
Airflow Volume m³/hr
116
116
116
IP Rating
IPX1
IPX1
IPX1
Dimensions (mm)
H W D
277 201 175
277
277
201
201
175
175
Finish
White
Stainless
Satin
HVAC |
263
Energy Efficient Hand Dryers
1.0kW Energy Efficient Fast Dry Hand Dryers
Save over
80% energy
vs conventional
2.4kW dryers
Energy Saving Features
• 10-12 second dry time - uses less energy per dry.
• Only 1kW rating - one of the lowest power consumptions in the energy efficient hand dryer market.
• Blue LED gives visible indication of drying zone ensuring hands are always in warm air stream.
• Automatic operation - reduces risk of spreading germs.
• 60 seconds auto shut-off.
• Class 1 Electrical Safety.
• IPX1 rated.
• Steel 1.2mm epoxy coated cover - extremely durable.
2 YR
NL1KWFD
Order Code
1051039964
Model No.
NL1KWFD
Noise Level
(dBA) at 1M
78
Output
(kW)
1
Airflow Volume m³/hr
113
IP Rating
IPX1
H
Dimensions (mm)
180
W D
250 138.5
Finish
White
Energy Efficient Jet Hand Dryer
Save over
80% energy
vs conventional
2.4kW dryers
The new Newlec jet dryer offers the ultimate in fast, hygienic and energy efficient hand drying. Its robust construction means this dryer is suitable for nearly all public places, including restaurants, pubs, office buildings, factories, supermarkets and hospitals.
Energy Saving Features
• 10 second dry time - uses less energy per dry
• Brushless lo-carbon long life DC motor adjustable between 750W
- 2050W
• Adjustable heater element - from
1.3kW down to 900W for even greater energy savings.
• Automatic operation - reduces risk of spreading germs.
• Antibacterial coating on dryer
- prevents multiplication and spreading of germs.
• Antibacterial HEPA dust filter - kills 99.9% of germs.
• Removable drip tray for easy maintenance.
• Blue LED gives visible indication of drying zone ensuring hands are always in warm air stream.
2 YR
Order Code
1051090935
Model No.
NLJETDRY
264
|
Colour
Silver
Output
(kW)
DC 750
Drying
Time
10 seconds
Airflow
Volume m/s
95
IP Rating
IPX4
Dimensions (mm)
H
W D
700 300 225
Hand Dryers
Hand and Face Dryers
• Automatic non-contact operation - less opportunity of passing on germs.
• Dry time - 26 seconds approx.
• 2mm metal cover (NLA48A and NLA48CA).
• Die cast aluminium cover (NL9AHD).
2 YR
Order Code Model No.
1000009512 NL9AHD
1050325785
1050325786
NLA48A
NLA48CA
NL9AHD
Output
(kW)
2.6
2.4
2.4
Airflow Volume m³/hr
275
345
345
1.8kW Hand Dryer
• Automatic non-contact infrared operation - less opportunity of passing on germs.
• High powered 1.8kW output.
• Vandal resistant die cast aluminium casing.
• Stylish design.
• 25 second dry time (approx).
1 YR
NLA48A
IP Rating
IP24
IPX1
IPX1
NLA48CA
Dimensions (mm)
H W D
264 275 177
248
248
284
284
202
202
Finish
White (Alu)
White
Stainless
Order Code
1051050520
Model No.
NLAHD1.8
Output
(kW)
1.8
1.5kW Hand Dryers
• Automatic operation - reduces risk of spreading germs.
• Class 1 Electrical Safety.
• Dry time 30 seconds (approx).
• ABS (polycarbonite) case - NLBHAA.
• Aluminium case - NLBHAM.
1 YR
Airflow Volume m³/hr
181
IP Rating
IPX1
NLAHD1.8
Dimensions (mm)
H W D
263 245 245
Finish
White Metal
Order Code
1050325782
1050325783
Model No.
NLBHAA
NLBHAM
Output
(kW)
1.5
1.5
Airflow Volume m³/hr
110
100
IP Rating
IP21
IP21
Dimensions (mm)
H W D
275 225 160
275 225 160
NLBHAA
Finish
White (ABS)
White (Alu)
HVAC |
265
Installed Electric Heating
Electricity as the main heating source for a home has many advantages over other forms of heating and is set to increase in popularity over the coming years.
This is because electric heating:
• Is easy to install whether in a new build property or as a refurb - no pipework to consider.
• Becoming increasingly energy efficient.
• Easily added to as a system - perfect for extensions, conservatories etc.
• Requires little to no ongoing maintenance.
• Controllability - can be controlled on a room by room basis or as a whole house system. No other system can achieve this level of control.
• Is 100% efficient at the point of use.
• Extremely safe as does not burn fossil fuels - no potential CO risks or requirements for flues.
Storage Heaters
Uses off peak electricity to store heat which is slowly released over the course of the day - efficient when a constant heat is required over long periods in a day.
Energy Efficient Storage Heaters
Highly sensitive thermostat accurrate to +/-0.1°C combined with a smart charge control module means these storage heaters can offer energy savings of over 30% compared to traditional manual models*
Combi Storage Heaters
A charge regulator automatically adjusts the amount of energy stored backed up by a built in convector heater that can provide completely silent top up heating.
Automatic Storage Heaters
A charge regulator automatically adjusts the amount of energy stored leading to significant savings over standard manual storage heaters.
Over
30% energy savings
*
See Page 267 See Page 268 See Page 268
Electric Radiators and Panel Heaters
Wall mounted heaters ideal for rooms that require heating for shorter periods of time during the day - particularly suited in rooms such as bedrooms, bathrooms, kitchens, conservatories and other rooms where constant heat is not required.
Electric Radiators
An incredibly efficient thermostat accurate to within +/-0.1°C combines with an energy optimiser which manages the flow of electricity to the radiator meaning that electric radiators can offer energy savings of over 40% when compared to traditional panel convectors.
Over
40% energy savings
*
Panel Convector Heaters
With a fast heat up time and powerful convection, panel heaters are ideal where heat is required quickly in short bursts.
Easy Programming
See Page 269 See Page 270
*All energy savings are based on an assumption of £0.14 per kWh peak and £0.06 per kWh off peak electricity rates
266
|
Energy Efficient Storage Heaters
Newlec energy efficient storage heaters have been designed to be the most economical electric storage heating solution. They reduce energy consumption by over 30% when compared to standard manual storage heaters.
• Direct replacement for standard storage heaters - simply replace existing heater with a Newlec energy efficient storage heater.
• Once installed simply set to automatic mode, set your required temperature and enjoy savings of over 30% compared to equivalent manual storage heaters.
1.
Easy Programming
Over
30%
energy saving
* when in auto mode
2.
1. Press the “mod” button to select the mode.
2. Use the “+” and “-” keys to select the desired temperature.
• Precision Thermostat - accurate to +/-0.1°C which leads to increased energy savings.
• Integrated convector heater for back-up heat if required.
• Five operating modes - suits any application and lifestyle.
• Built in daily programmer - allows user to minimise wasted heat when room is not in use.
• Electronic Smart Charge Control module.
- Monitors the room temperature and the energy
consumption of the heater.
- Automatically adjusts the charging and
consumption during the off peak period.
- Only stores required energy.
Guide to Electric Heating Costs - Storage Heaters
A test comparing energy efficient storage heaters with manual storage heaters was undertaken under the following conditions assuming informed user intervention on the manual heater every three to four weeks - no user intervention in energy efficient storage heaters required.
Energy Efficient Storage Heater
1.3kW (NLEESH2)
1.7kW Manual Storage kWh
Used
76387
121088
Cost
@ £0.06
£45.84
£72.65
Approx savings vs manual storage heaters
37%
Approx savings vs automatic storage heaters
*
26%
Test Conditions
Room size - 3.5M x 3M, 2.4M (height).
Temperature - 07.00 - 23.00 21°C.
23.00 - 07.00 18°C.
Time period - 6 months
(September to February inclusive).
*An automatic or combination storage heater would be expected to save c.15% over a standard manual storage heater. This would still result in the energy efficient storage heater offering approximately 26% energy savings (c.£61.75 running cost).
Energy Efficient Storage Heaters
Order Code
1051058538
1051058539
1051058540
1051058541
Model No.
NLEESH1
NLEESH2
NLEESH3
NLEESH4
Input
Rating
(kW)
0.98
1.3
1.95
2.6
Convector
Max Output
Rating (kW)
0.45
0.6
0.9
1.2
Storage Charge
Acceptance - 7Hr
Continuous (kW)
6.8
9.1
13.6
18.2
No of
Bricks
4
8
12
16
Weight Inc
Bricks (kg)
59
77
112
147
Dimensions (mm)
H W D
730 550
730 660
180
180
730 890
730 1110
180
180
For energy efficient storage heater sizing charts see page 336-337
* All energy savings are based on an assumption of £0.14 per kWh peak and £0.06 per kWh off peak electricity rates.
5 YR
HVAC |
267
Storage Heaters
Storage heaters are specifically designed to operate using cheaper off-peak electricity to store heat. When the off-peak period finishes the heat is gradually released into the room over the course of the day. All Newlec storage heaters have the following benefits:
Room temperature boost control increases heat output when required
• Willow white colour.
• Drip proof (IPX2 rated).
• Automatic charge regulator - automatically adjusts the level of input charge to compensate for changing weather conditions without user intervention.
• Manual reset thermal cut-out.
• Compatible with all off-peak tariffs.
NL10658
Two types of storage heaters are available, each with their own benefits:
Automatic Storage Heaters
• Thermostats have an automatic charge regulator. This measures the temperature in the room and automatically adjusts the charge regulator accordingly. This can lead to significant running cost savings over manual storage heaters.
Combination Storage Heaters
All the benefits of an automatic storage heater plus the added advantage of having a built in convector heater - essentially offering two heaters in one compact space. Benefits of this include:
• Convector supplies completely silent top up heating.
• Convector thermostat can be set to maintain constant room temperatures and automatically switch on as necessary.
• Can provide top up heat even if no heat has been stored overnight - particularly useful in summer months if there is a sudden cold spell.
Automatic Storage Heaters
Order Code
1051061831
1051011765
1051011766
1051011767
Model No.
NLASH0.8
NL10579
NL10580
NL10581
Input Rating
(kW)
0.85
1.7
2.55
3.4
Storage Charge
Acceptance - 7Hr
Continuous (kW)
6
12
18
24
No. of
Elements
1
2
3
4
No. of
Bricks
4
8
12
16
Weight Inc
Bricks (kg)
41
77
110
145
H
Dimensions (mm)
W D
700
700
700
700
332
560
788
1016
170
170
170
170
2 YR
Combination Storage Heaters
Order Code Model No.
1050371283 NL10657
1050371284 NL10658
1050371285 NL10659
Input Rating
(kW)
1.7
2.55
3.4
Convector Max
Output Rating
(kW)
1
1.5
2
Storage Charge
Acceptance - 7Hr
Continuous (kW)
12
18
24
No. of
Elements
2
3
4
No. of
Bricks
8
12
16
Weight Inc
Bricks (kg)
77
111
146
H
Dimensions (mm)
W D
700
700
700
560
788
1016
204
204
204
268
|
1 YR
Electric Radiators
Electric radiators are a real innovation in cost effective electric heating. They provide central heating that can be controlled room by room, hour by hour to perfectly suit the users requirements.
• Direct replacement for both panel convector and storage heaters.
• Electronic energy optimiser - restricts flow of electricity to the radiator meaning on average a 1.5kW heater uses only 0.63kW of electricity to maintain constant room temperature leading to increased energy savings.
• Three operating modes - Comfort, Economy and Frost protection.
• Quick-fix wall mounting brackets - save up to 50% on install time.
• Environmentally friendly fluid filled aluminium fins means that the heat is transferred quickly and evenly into the room via both radiation and convection.
Offers total control room by room with built-in daily/weekly programmer
Highly Accurate Thermostat
The more accurate the thermostat then the more efficient the heater. Newlec electric radiators and Energy Efficiency Storage Heaters are accurate to +/-0.1°C giving the following energy savings vs less accurate thermostats.
• Thermostat with +/-0.3°C uses up to 4.8% extra energy.
• Thermostat with +/-0.5°C uses up to 8% extra energy.
• Thermostat with +/-1.0°C uses up to 16% extra energy.
Guide to Electric Heating Costs - Electric Radiators vs Panel Heaters
The following table is a guide to costs based on a required temperature of 21°C, ceiling height of 2.4mtrs and ‘U’ values, ext.walls 1.5, floors 0.75, roof insulation 0.31 and glazed areas 2.9. The exact heater required would depend on the room size that needed to be heated. For a more accurate guide we would require more information, including actual “U” values.
Please contact us to help you select and size your radiators accurately.
All costs are based on an assumption of £0.14 per Kwh peak and £0.06 per Kwh off peak electricity rates.
For more detailed sizing guides for all our heaters please see pages 336-337.
Typical energy savings
40%
Heater
Model
Heater Type
NLHRADD500
NLHRADD750
Electric Radiator
Electric Radiator
NLHRADD1000 Electric Radiator
NLHRADD1250 Electric Radiator
NLHRADD1500 Electric Radiator
NLHRADD2000 Electric Radiator
Rating
(Kilowatts)
0.5
0.75
1
1.25
1.5
2
Approximate Running
Costs per Hour
£0.03
£0.04
£0.06
£0.07
£0.09
£0.12
Heater
Model
NLPH750
NLPH1250
NLPH1500
NLPH2000
NLPH3000
Heater Type
Panel Heater
Panel Heater
Panel Heater
Panel Heater
Panel Heater
Rating
(Kilowatts)
0.75
1.25
1.5
2
3
Approximate Running
Costs per Hour
£0.07
£0.12
£0.15
£0.20
£0.29
5 YR
Order Code
1051058532
1051058533
1051058534
1051058535
1051058536
1051058537
Model No.
NLHRADD500
NLHRADD750
NLHRADD1000
NLHRADD1250
NLHRADD1500
NLHRADD2000
Output
(kW)
0.5
0.75
1
1.25
1.5
2
For electric radiator sizing charts see page 336
Controls
Digital
Digital
Digital
Digital
Digital
Digital
No of
Elements
10
12
14
4
6
8
Weight
(kg)
16
19
22
8
11
13.5 580
580
580
580
Dimensions (mm)
H W D
580
580
415
575
100
100
735
895
1055
1215
100
100
100
100
HVAC |
269
Panel Heaters
Panel Heaters
The slimline range of Newlec panel heaters are ideal for rooms that require rapid heat for short periods of time during the day e.g. bedrooms, bathrooms and conservatories.
IPX4
rated for use in bathrooms and other wet areas
• Willow white to match Newlec storage heaters.
• Temperature settings from 35°C down to a frost protection setting (5°C).
• Thermostat accurate to +/-1.5°C.
• Detachable hinged wall mounting frame for fast installation and easy cleaning.
• Available in thermostatic or 24hr timer variants.
24 Hour Timer Thermostatic Panel Heaters
• 24 hour programmable timer.
• Timer can be set to switch on and off as often as required throughout the day
(in 20 minute intervals).
• Override switch enables the timer to be by-passed without altering the pre-set programme.
Thermostatic Panel Heaters
• Highly accurate adjustable thermostat.
• Suitable for domestic or commercial use.
NLPH750
2 YR
Order Code
1050335059
1050335060
1050335061
1050335062
1050363032
Model No.
NLPH750
NLPH1250
NLPH1500
NLPH2000
NLPH3000
Loading
(kW)
0.75
1.25
1.5
2
3
Weight
(kg)
6.2
6.6
6.6
8
10
Dimensions (mm)
H W D
430
430
430
430
430
620
690
690
860
860
108
108
108
108
143
24 Hour Timer Thermostatic Panel Heaters
• 24 hour programmable timer.
• Timer can be set to switch on and off as often as required throughout the day (in 20 minute intervals).
• Override switch enables the timer to be by-passed without altering the pre-set programme.
NLPH750T
2 YR
Order Code
1050335063
1050335064
1050335065
1050335066
1050363033
Model No.
NLPH750T
NLPH1250T
NLPH1500T
NLPH2000T
NLPH3000T
Loading
(kW)
0.75
1.25
1.5
2
3
Weight
(kg)
6.2
6.6
6.6
8
10
For panel heater sizing charts see page 337
Dimensions (mm)
H W D
430
430
430
430
430
620
690
690
860
860
108
108
108
108
143
270
|
Portable Heaters
Fan Heaters
Model No.
NLFH2KW
NL202
Dimensions (mm)
H W D
150 265 260
112 215 192
1 YR
Order Code Model No.
1051039961 NLFH2KW
1000009542 NL202
Loading
(kW)
2
2
2kW Convector Heater
• 3 heat settings - 0.75kW, 1.25kW and 2kW.
• Silent operation.
• Thermostatic control.
• Safety thermal cut-out.
• BEAB approved.
Model No.
NLCH2KW
Dimensions (mm)
H W D
370 530 110
Order Code Model No.
1051039978 NLCH2KW
Loading
(kW)
2
Convector Heaters
1 YR
NLFH2KW
• 2.0kW maximum output.
• 2 heat settings (1.0kW/2.0kW) and cool blow.
• Thermostat.
• Auto re-set thermal cut-out and safety fused units.
NL202
• Thermostatic control with frost protection.
• Choice of heat settings including cool blow.
• Mains on neon indicator.
• Manual reset cut-out and safety fused link.
• BEAB approved.
NLCH2KW
NLH1000A
Standard
• White with grey trim.
• Thermostatic control and twin heat settings.
• Frost protection feature.
• Supplied with feet, wall brackets, cable and fitted plug.
• Overheat protection.
NLH1001A
Timer Option
• As standard but with a 24 hour programmable timer.
Model No.
NLH1000A
NLH1001A
NLH1002A
NLH1003A
Dimensions (mm)
H W D
420 575 200
420 575 200
420 575 200
420 695 200
Dimensions including feet
Order Code
1051091528
1051091529
1051091530
1051091531
Model No.
NLH1000A
NLH1001A
NLH1002A
NLH1003A
Loading
(kW)
2
2
2
3
Thermostat &
Heat Selection
✔
✔
✔
✔
NLH1002A
Turbo Option
• As standard but with a turbo fan boost for extra heat when required.
Timer
✘
✔
✘
✘
Turbo
✘
✘
✔
✘
Weight
(kg)
3.6
3.7
3.9
4.2
1 YR
HVAC |
271
Oil Filled Heaters & Bathroom Heaters
Oil Filled Column
• White/light grey colour.
• Thermostatically controlled.
• Frost protection.
• Auto reset safety cut-out.
1 YR
Oil Filled Radiator
NLH2000
Bathroom Heater
NLBDHN
Model No.
NLOFCR
Dimensions (mm)
H W D
650 405 160
Order Code Model No.
1050151441 NLOFCR
Loading
(kW)
1.5
Heat
Settings
2
Weight
(kg)
10
• Willow white colour.
• Thermostatic control.
• Ideal for background or full heating.
• Free standing or wall mounted.
• Electrical reset safety cut-out.
1 YR
Model No.
NLH2000
Dimensions including feet
Dimensions (mm)
H W D
648 1084 230
Order Code Model No.
1052025187 NLH2000
Loading
(kW)
1.5
Heat
Settings
Variable
Weight
(kg)
17.8
• Pullcord.
• 2kW maximum output.
• 1kW output selectable on installation.
• Energy saving thermostat – switches to 1kW setting when room is warm (functions on 2kW setting only).
• Visual ON/OFF indicator.
• Designed for high level mounting.
• IPX2 rated.
1 YR
Model No.
NLBDHN
Dimensions (mm)
H W D
242 229 109
Order Code Model No.
1050184587 NLBDHN
IP Rating
IPX2
272
|
Plinth, Overdoor & Commercial Heaters
Plinth Heater
• Supplied with three fascias - brown, white and stainless steel.
• Pressed steel construction.
• Three output settings - 800W, 1600W and 2400W.
• Thermostatically controlled with thermal cut-out.
• Pre-wired with 1.5M mains lead.
1 YR
Model No.
NLPH24KW
Dimensions (mm)
H W D
125 480 200
Order Code Model No.
1050390629 NLPH24KW
Loading
(kW)
2.4
Heat
Settings
3
Overdoor Heater
• 3kW heat output.
• 1.5kW half heat setting.
• Cool blow function.
• Durable steel case.
• Wall or ceiling installation.
• Bracket included.
1 YR
Model No.
NL3ACN
Dimensions (mm)
H L D
201 557 100
Order Code Model No.
1051011600 NL3ACN
Element
Type
Wire Strung
Supply
Voltage (V)
230 - 240
Thermal
Cut-Out
Manual Reset
Airflow
(m/s)
6.2
Noise Level dB(A) @ 1M
50.5 (Full Load)
Commercial Fan Heater
Powerful commercial wall mounted heater with air circulation facility for summer use.
• 3kW power.
• Polycarbonate cased body.
• Nichrome wire heating elements.
• Multi directional wall bracket.
• Frost protection setting.
1 YR
Model No.
NL10
*On full tilt
Dimensions (mm)
H
370
L
267
Order Code Model No.
1000008148 NL10
Output
(kW)
3
D
370*
Airflow
(l/s)
83
NLPH24KW
NL3ACN
NL10
HVAC |
273
Frost Protection & Tubular Heaters
500W Frost Protection Fan Heater
Compact durable heater for use in a wide range of applications providing low level localised heat frost protection.
• 500W output.
• Thermostat.
• Frost protection.
• Mains neon indicator.
• Overheat protection.
• Free standing or wall mounted (can be used either horizontally or vertically when floor mounted).
1 YR
NLH5MPH
Model No.
NL5MPH
Dimensions (mm)
H L D
330 255 150
Order Code Model No.
1050152359 NL5MPH
Elements
Type
Mineral Filled
Wattage
(W)
500
Thermostatic Tubular Heaters and Guards
• A new range of energy efficient tubular heaters to provide ambient and frost protection heating for numerous applications including airing cupboards, greenhouses, shop windows, conservatories, garages and shed.
• Provides low-cost heating with a built-in thermostat that keeps energy usage to a minimum.
• Discreet mounting brackets included - suitable for walls or floors.
• Reversible left or right hand cable entry.
• IPX4 rated.
• Available in six sizes - from 1' to 6' to suit any application.
1 YR
NLTTH1 NLTTH2
NLWG21
NLTTH4 NLTTH6
Order Code
1051058518
1051058519
1051058521
1051058523
Model No.
NLTTH1
NLTTH2
NLTTH4
NLTTH6
Size
(feet)
1
2
4
6
Output
(W)
40
80
160
240
Dimensions (mm)
H W D
81 408 80
81 713 80
81 1323 80
81 1933 80
Tubular Heater Guards
• Welded wire guards to protect heaters from damage caused by vandalism, interference or accidents.
• Available for 2', 4' and 6' heaters.
• Electro galvanised to BS 1706 ZN3.
Order Code Model No.
1050150546 NLWG19
1050150547 NLWG20
1050150548 NLWG21
Size
(ft)
2
4
6
Finish
Galvanised
Galvanised
Galvanised
Dimensions
(inches)
29 x 6 x 6
53 x 6 x 6
74 x 6 x 6
274
|
Electric Towel Rails
The new range of Newlec electric towel rails come in a variety of stylish designs and a choice of heat outputs. Both white and chrome finishes are available with a variety of heat outputs matched to the size of the rail.
S-Shaped Electric Towel Rails
• IPX4 rated.
• Rapid heat up.
• Lightweight and easy to install.
• Robust mounting brackets included.
1 YR
NLSWH80W NLSCH50W
Order Code Model No.
1051039951 NLSWH80W
1051039952 NLSCH50W
Output
(W)
80
50
Dimensions
H x W (mm)
645 x 500
645 x 500
Design
S-Shaped
S-Shaped
Finish
White
Chrome
Ladder Style Electric Towel Rails
• Steel construction with high quality white and chrome finishes.
• IP55 rated.
• Wall fixings and comprehensive step by step fitting instructions included.
• Plug and vent included.
• Heating element included.
1 YR
Order Code Model No.
Output
(W)
1051039954 NLFWH250W 250
1051039953 NLFCH150W 150
1051039955 NLFCH250W 250
1051039956 NLFCH400W 400
1051039957 NLCCH250W 250
Dimensions
H x W (mm)
1100 x 500
700 x 400
1100 x 500
1500 x 500
1100 x 500
Design
Flat
Flat
Flat
Flat
Curved
Finish
White
Chrome
Chrome
Chrome
Chrome
Electric Towel Rail Controllers
• IPX4 rated.
• White or chrome finish.
• Five power settings.
• Eco timer function.
2 YR
Order Code
1051039959
1051039960
Model No.
NLWHCON
NLCHCON
Finish
White
Chrome
NLFCH150W NLFWH250W NLCCH250W
NLWHCON NLCHCON
HVAC |
275
Room Thermostats/Digital Programmers
Electronic Room Thermostat
• Easily adjustable dial with clearly marked scale.
• 5˚C to 30˚C temperature range.
• Surface mount with wall plate included.
• Temperature swing adjustable (using jumper) between 1˚C and 0.5˚C.
• 3 Wire connection (double insulated).
3 YR
NLBRT1
7 Day Programmable Room Thermostat
Order Code Model No.
1050378520 NLBRT1
Description
Electronic Room Thermostat
*Resistive load rating - inductive load rating in brackets.
Load
Rating*
6A (2A)
• 7 day time and temperature programming with digital accuracy.
• 10°C to 30°C temperature range adjustable in 0.5°C steps.
• 6 different time/temperature periods.
• Automatic summer/winter changeover with frost protection.
• Easy +/- illuminated push button setting.
3 YR
NL1CHDPT1
Order Code Model No.
Description Load
Rating*
1050378522 NL1CHDPT1 7 Day Programmable Room Thermostat 3A (1A)
*Resistive load rating - inductive load rating in brackets.
7 Day Digital Central Heating and Hot Water Programmers
NL7DDPT1
• Single channel 7 day programming for use with room thermostats.
• 1 - 9 hour boost facility for instant control.
• 3 different time/temperature periods (5 day plus 2 or 7 day programming).
• Automatic summer/winter changeover and holiday mode setting.
• Factory fitted battery for memory back-up - remembers settings even after a power cut.
3 YR
NL2CHDPT1
All the benefits of NL7DDPT1 PLUS
• Two channel digital heating programmer - allows independent control of central heating and hot water.
• Suitable for pump and gravity fed systems.
• Heat/hot water symbol displays on call for heat/water.
3 YR
Order Code Model No.
Description Load Rating
@ 230V*
1050378521 NL7DDPT1 7 Day Programmable Room Thermostat 3A (1A)
1050378523 NL2CHDPT1 2 Channel 7 Day Digital Programmer 3A (1A)
*Resistive load rating - inductive load rating in brackets.
276
|
Economy 7 Controllers/Immersion Heater Controllers
Economy 7 Timeswitches
NLTRT7DM
• Designed for use with Economy 7 off peak rate overnight electricity plans.
• 24hr segment time setting dial with 15 minute switching intervals for customised programming.
• Completely interchangeable with previous Newlec models as well as Horstmann and Sangamo Economy 7 units.
• Fits and supplied with a standard size Economy 7 wall box with industry standard plug-in connections.
• 4 Boost demand options – 15, 30 minutes, 1 and 2 hours.
Order Code Model No.
1051024051 NLTRT7DM
1051024052 NLTRT7DD
Description
Economy 7 Analogue Timeswitch
Economy 7 Digital Timeswitch
3 YR
All the benefits of NLTRT7DM PLUS
• Digital accuracy improves system efficiency and reduces running costs.
• Accommodates up to 3 off-peak hot water or heating periods every 24 hours.
• Pre-selected timing options - manually adjustable to allow customised programming.
• Easy view 12 hour am/pm clock/timer display illuminates on setting.
• Simple push button setting and select modes with full screen information.
24 Hour Immersion Heater Time Controller
• Specially designed for installation with both new and existing immersion heater systems.
• Up to 24 ON & OFF programmes (additional pins required).
• Bottom or rear entry for cable.
3 YR
Order Code Model No.
1050378529 NL24HRIHTS1
Description
24 Hour Segment Immersion Heater Controller
* Resistive load rating - Inductive load rating in brackets
24 Hour Immersion Heater Timeswitches
• 96 quick-set segments for up to 48 ON/48 OFF programmes.
• Red LED ‘Mains ON’ and green LED ‘Output’ indicators for easy viewing.
• Special ‘Traffic Light’ slider switch for easy ON (green), Auto (green & red) and
OFF (red) mode indication.
• NL24HRIHTS fits a standard flush or surface mount box min. 32mm deep.
• NL24HRTS is slimline and switches up to 750W incandescent or halogen lighting/750W fluorescent lighting/100W compact fluorescent lighting
(not suitable for discharge lighting).
3 YR
Load
Rating*
13A (5A)
NL24HRIHTS
Order Code Model No.
1051040108 NL24HRIHTS
1051040110 NL24HRTS
Description
24 Hour Compact Immersion Heater Timeswitch
24 Hour Slimline General Purpose Timeswitch
* Resistive load rating - Inductive load rating in brackets
Load
Rating*
16A (6A)
16A (6A)
NL24HRIHTS1
NL24HRTS
HVAC |
277
Immersion Heater Controllers/General Purpose Timeswitch
7 Day Electronic Immersion Heater Timeswitch
• 4 ON/4 OFF easy-set programme periods per day, 28 ON/28 OFF programmes per week.
• Extra large ‘Easy View’ screen with blue LED backlighting.
• Optional 1 and 2 hour boost button..
• Automatic Summer/Winter changeover
• NL24HR7DIHTS fits a standard flush or surface mount box min. 32mm deep.
3 YR
NL24HR7DIHTS
NL24HR7DELTS
2 Hour General Purpose Boost Timer
Order Code Model No.
Description
1051040109 NL24HR7DIHTS 7 Day Electronic Compact Immersion Heater Timeswitch
1051040111 NL24HR7DELTS 7 Day Electronic Slimline General Purpose Timeswitch
* Resistive load rating - Inductive load rating in brackets
Load
Rating*
16(4)A
16(4)A
• Boost timer for immersion heaters, room heaters, towel rails etc.
• Automatically switches off at end of set time period.
• ON time can be increased in four step - 15, 30, 60 or 120 minutes.
3 YR
NL2HRBT1
Order Code Model No.
1050378519 NL2HRBT1
Description Load
Rating*
2 Hour Boost Timer 13A (3kW)
Fused Spur Timeswitches
NLFST1 NLFST2
• Easy view 24 hour digital clock/timer display.
• Optional 1 or 2 hour boost facility.
• Integral memory backup battery retains programmes in event of power failure.
• Suitable for use with up to 3kW immersion heaters.
• Switches the following lighting loads: 750W incandescent or halogen lighting, 500W fluorescent lighting, 100W compact fluorescent lighting
(CFL’s) and 200W LED lighting. Not suitable for discharge lighting.
3 YR
Order Code
1051058516
1051058517
Model No.
NLFST1
NLFST2
Description
24 Hour Fused Spur Timeswitch
7 Day Fused Spur Timeswitch
Plug-In Time Controllers
NL24HRST1 NL24HR7DDTS1
• Plug-in controllers to switch appliances on/off at preset times.
• Compact design.
• Suitable for 13A (3kW) appliances, filament lamps up to 400W and 100W low energy/fluorescent lighting.
• Up to 24 on/off programmes per day (NL24HRST1).
• Up to 20 on/off programmes selectable over individual days.
3 YR
Order Code
1050378517
1050378518
Model No.
NL24HRST1
NL24HR7DDTS1
278
|
Easy Fit Electric Shower
• 8 water connection options - allowing for pipe entry from top, bottom, side or rear of the shower.
• 3 cable entry options - allowing for cable entry from top, bottom or rear from the right hand side of the shower.
• Full accessory kit including easy rub-clean single mode shower head and soap dish.
• Large footprint covers most other electric showers - less likelihood of having to alter existing tiling or decoration.
• Improved working space in the shower makes installation less fiddly and time consuming.
2 YR IPX4
Energy Efficiency Class -
A
Water Pipe Entry
Electrical Cable Entry
Easy Fit Electric Showers
Order Code
1051091527
Model No.
NLSHOWER1
Output
(kW)
8.5
Power
Settings
3
Recommended
Cable Size
6-10mm²
Recommended
Fuse Rating
40 Amps
Dimensions
(mm)
335 x 225 x 89.5
Upgrade from a 7.2kW shower to an 8.5kW. The kW rating affects the water flow of a shower with an 8.5kW rated shower having up to 18% more flow than a 7.2kW rated version.
Please note that 8.5kW rated showers require 40 amp fuses and must be fitted in accordance with BS 7671 (IEE Wiring Regulations) and Part P of the Building Regulations.
For 40 amp breakers please see page 155.
Professional Easy Fit Electric Shower
All the benefits of the Newlec Easy Fit shower PLUS:
• Additional 3 cable entry options and dual terminal blocks - allowing for cable entry from top, bottom or rear of the shower from the left or right hand side.
• Chrome accessory kits with 6 mode shower head and adjustable fixing brackets meaning existing fixing points can be used when replacing an existing shower.
• Push button Start/Stop for “set and forget” operation.
• Removable, easy clean inlet filter for easy maintenance.
2 YR IPX4
Energy Efficiency Class -
A
Water Pipe Entry
Electrical Cable Entry
NLSHOWER2
Order Code
1051091526
Model No.
NLSHOWER2
Output
(kW)
8.5
Power
Settings
3
Recommended
Cable Size
6-10mm²
Recommended
Fuse Rating
40 Amps
Dimensions
(mm)
335 x 225 x 89.5
Upgrade from a 7.2kW shower to an 8.5kW. The kW rating affects the water flow of a shower with an 8.5kW rated shower having up to 18% more flow than a 7.2kW rated version.
Please note that 8.5kW rated showers require 40 amp fuses and must be fitted in accordance with BS 7671 (IEE Wiring Regulations) and Part P of the Building Regulations.
For 40 amp breakers please see page 155.
HVAC |
279
Instantaneous Water Heaters
Why use them?
• Provides instant unlimited hot water to one or more sinks/basins - ideal for handwashing.
Benefits
• Easy to install - simply requires cold water feed and mains electricity.
• Energy efficient as no stored water needs to be heated - Energy Efficient Class A-rated.
Where to use them?
• Cloakrooms, kitchens and canteens where no suitable hot water store is available.
Manual Handwash
• Energy efficient - located at point of use eliminating heat loss through long pipe runs and only heats water on demand.
• Stainless steel 200mm swivel spout for durability.
• Preset safety cut-out - prevents overheating.
• Temperature stabiliser - ensures temperature of water is maintained, preventing scalding.
• Pressure relief device - prevents high pressure build up should unit become blocked or frozen.
2 YR
Energy Efficiency Class -
A
NLMHW3KW
Automatic Handwash
Order Code
1051043912
Model No.
NLMHW3KW
Power
Rating (kW)
3
Dimensions
H x W x D (mm)
235 x 151 x 98
All the benefits of manual handwash plus:-
• Easy to use “No Touch” on/off dial.
• Ideal for use in hospitals and GP surgeries - reduced risk of spreading germs from touching contaminated dials.
• Tamper-proof adjuster for temperature and flow control - ensuring a consistent temperature.
2 YR
Energy Efficiency Class -
A
NLAHW3KW
Instantaneous Inline Handwash
NLNCT
Order Code
1051043913
Model No.
NLAHW3KW
Power
Rating (kW)
3
Dimensions
H x W x D (mm)
235 x 151 x 87
• Energy efficient - only heats water on demand so no standing heat loss.
• Bare wire heating technology gives fast heat up times.
• Small compact shape, ideal for undersink mounting.
• Intended for use with spray head taps (NLNCT).
• Temperature stabilised and electronic temperature control maintain water temperature to +/- 1°C.
Energy Efficiency Class -
A
Order Code Model No.
1051058684 NLIWH4.4
1051058685 NLNCT
Power Rating
(kW)
4.4
-
Dimensions (mm)
H x L x D
140 x 190 x 80
-
NLIWH4.4
280
|
Why use them?
• Provides hot water to a single sink or basin
- oversink and undersink models available.
Undersink units require vented taps.
Benefits
• Easy to install - simply requires cold water feed and mains electricity.
Vented Water Heaters
Where to use them?
• Kitchen sinks in workplaces, offices, workshops, garages, industrial units and portable buildings.
Oversink Vented Water Heater
• Complete with tap and spout.
• No need for expansion vessel, pressure relief or pressure reducing valve - easy to install.
• Safety resettable thermal cut out - simply switch off to reset.
• White corrosion proof case for durability.
• 1m pre-wired cable - saving time on installation.
1 YR
Energy Efficiency Class -
A
Order Code Model No.
1051043904 NLVOS5L
Power
Rating (kW)
2
Capacity
(Litres)
5
Dimensions
H x W x D (mm)
400 x 270 x 180
Undersink Vented Water Heater
All the benefits of an oversink vented water heater plus:-
• Comes complete with vented mixer tap - no need to purchase any additional accessories.
• Unit is hidden under the sink with only the mixer tap visible on the work surface.
• Vented mixer tap is supplied with three flexible hoses for ease of installation.
1 YR
Energy Efficiency Class -
A
Order Code Model No.
1051043905 NLVUS5L
Power
Rating (kW)
2
Capacity
(Litres)
5
Dimensions
H x W x D (mm)
400 x 270 x 180
Accessory
• For use with NLVUS5L undersink vented water heater (shown above).
Order Code
1051043906
Model No.
NLVMT
Description
Vented Mixer Tap
Dimensions
H x W (mm)
230 x 170
NLVUS5L
NLV0S5L
HVAC |
281
Unvented Water Heaters/Flat Back Cisterns
Unvented Water Heaters
Why use them?
• Provides hot water to single or multiple outlets.
Fed directly from the cold water mains supply and operates at the same water pressure.
Benefits
• Provides high flow rates and balanced hot/cold water supplies
• Can be used with standard taps.
Where to use them?
• Cloakrooms with multiple wash basins, kitchens in offices, shops and commercial premises and student accommodation.
NL10LUWH
• External temperature control and neon element on indicator.
• IPX4 rated - protected against water splashing from any direction.
• Safety manually resettable thermal cut out.
• Pressure relief valve supplied - additional safety feature that must be fitted to prevent failure should pressure build up in the unit without being released.
• Pre-wired 1.5M cable - saving time on installation.
1 YR WRAS
Energy Efficiency Class -
B
Order Code Model No.
1051043909 NLEV
1051043910 NLPRV
Description
1051043907 NL10LUWH 2kW 10L Unvented Water Heater
1051043908 NL15LUWH 2kW 15L Unvented Check Valve for Unvented
Expansion Vessel and Check Valve for Unvented
Pressure Reducing Valve for Unvented Heater
Power Rating
(kW)
2
2
-
-
Capacity
(Litres)
-
-
10
15
Dimensions
H x W x D (mm)
410 x 310 x 280
530 x 310 x 280
-
-
Weight
Empty (kg)
-
-
6.8
8.3
Weight Full
(kg)
16.8
23.3
-
-
Heat Up
(mins)
-
-
23
35
Hot
Cold
Unvented water heater
Pressure relief valve
(Included with
NL10LUWH &
NL15LUWH)
Expansion vessel
(NLEV)
T piece
To drain
(waste)
Check valve
(NLEV)
2.8 (10 l) or 4.2 (15 l) metres is required for expansion in pipework
Nearest Cold
Draw Off
Pressure reducing valve
(NLPRV)
Service valve
Cold water mains
Additional accessories may be needed to comply with the Water
Regulations.
• Pressure Reducing Valve (NLPRV) - Required if water pressure is above 4.2 bar.
• 2 litre expansion vessel and check valve (NLEV) - Should be installed if the length of pipework is too short to accommodate the expanded hot water without re-entering the cold water supply. 2.8M of pipework is required for a 10 litre heater and 4.2M pipework is required for a 15 litre heater.
Flat Back Cisterns
NLFBC25A
• 25 litre capacity.
• Thermostat adjustable between 18°C to 70°C with manually resettable over temperature cut-out for additional safety.
• Long life alloy sheathed 3kW element.
• Simple left or right hand water inlet and overflow connections for ease of installation.
• Sheet steel casing finished in white stoved enamel for added durability.
2 YR
Energy Efficiency Class -
B
Order Code
1051043914
Model No.
NLFBC25A
Power
Rating (kW)
3
Capacity
(Litres)
25
Dimensions
H x W x D (mm)
682 x 609 x 234
282
|
Boiling Water Dispensers
Why use them?
• Boiling water dispensers store boiling water ready for instant use.
Benefits
• Saves time as no waiting for kettles to boil.
• Saves energy as you only use the water needed.
• Saves space - uncluttered worktops.
Boiling Water Dispensers
Where to use them?
• Ideal usage: Any commercial environment where there is a demand for boiling drinking water.
The Newlec range offers benefits including:
• Easy to install with easily accessible plumbing fittings.
• Removable steam condensation chamber for easy maintenance access.
• Electronic thermostat for greater control of water temperature up to boiling point.
• Dry start protection with a self-resetting thermal cut-out.
• Boil dry protection with a manually resettable cut-out.
2 YR
Order Code
1051043915
1051043916
Model No.
NLBWD2.5A
NLBWD5
Capacity
(Litres)
2.5
5
Power Rating
(kW)
2.5
2.5
Dimensions
H x W x D (mm)
445 x 290 x 190
510 x 335 x 200
Immersion Heaters
• All immersion heaters are fitted with RDT thermostats (Resettable Dual Thermostats) which offer a combined thermostat and resettable safety cut-out.
• Adjustable from 10°C to 60°C - factory preset at 60°C.
• Suitable for use in both hard and soft water conditions.
2 YR
Order Code
1051043918
1051043920
Model No.
NLIIH11
NLIIH27
Description
3kW 11" Incalloy Immersion Heater
3kW 27" Incalloy Immersion Heater
Power Rating
(kW)
3
3
Thermostats
• RDT thermostats (Resettable Dual Thermostats) offer a combined thermostat and resettable safety cut-out.
• Provide a simple method of upgrading immersion heaters to meet latest BS standards
(BS EN 60335-2-73) without draining the hot water cylinder.
• Thermostats adjustable from 10°C to 60°C - factory preset at 60°C.
• Manual reset feature.
2 YR
Order Code
1051043921
1051043922
Model No.
NLTHERM7
NLTHERM18
Description
7" Dual Thermostat Resettable Cutout
18" Dual Thermostat Resettable Cutout
Power Rating
(kW)
3
3
NLBWD2.5A
NLIIH11
NLTHERM7
HVAC |
283
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project