Advantech | ARK-3382 | TEST REPORT - RS Components International

Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
FCC 47 CFR PART 15 SUBPART B
TEST REPORT
For
IPC
Model: ARK-3381; ARK 3382
Trade Name: ADVANTECH
Issued for
Advantech Co., Ltd.
No. 1, Alley 20, Lane 26, Rueiguang Road, Neihu District,
Taipei 114, Taiwan, R.O.C.
Issued by
COMPLIANCE CERTIFICATION SERVICES INC.
No. 81-1, Lane 210, Bade Rd., 2, Luchu Hsiang,
Taoyuan Hsien, (338) Taiwan, R.O.C.
TEL: 886-3-324-0332
FAX: 886-3-324-5235
Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. Ltd. This document may be altered or revised by Compliance Certification Services
Inc. personnel only, and shall be noted in the revision section of the document.
Page 1
Total Page: 30
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
TABLE OF CONTENTS
1
TEST RESULT CERTIFICATION ............................................................................................................3
2
EUT DESCRIPTION...................................................................................................................................4
3
TEST METHODOLOGY............................................................................................................................4
3.1
3.2
EUT SYSTEM OPERATION .............................................................................................................6
DECISION OF FINAL TEST MODE ................................................................................................6
4
SETUP OF EQUIPMENT UNDER TEST..................................................................................................7
5
FACILITIES AND ACCREDITATIONS...................................................................................................8
5.1
5.2
6
INSTRUMENT AND CALIBRATION....................................................................................................10
6.1
6.2
7
FACILITIES........................................................................................................................................8
LABORATORY ACCREDITATIONS AND LISTINGS ...................................................................9
MEASURING INSTRUMENT CALIBRATION.............................................................................10
TEST AND MEASUREMENT EQUIPMENT ................................................................................10
LINE CONDUCTED & RADIATED EMISSION TEST.........................................................................12
7.1
7.2
7.3
7.4
LIMIT…. ..........................................................................................................................................12
TEST PROCEDURE OF LINE CONDUCTED EMISSION...........................................................13
TEST PROCEDURE OF RADIATED EMISSION..........................................................................15
TEST RESULTS ...............................................................................................................................17
APPENDIX 1 - PHOTOGRAPHS OF TEST SETUP.....................................................................................25
Page 2
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
2 EUT DESCRIPTION
Product
IPC
Trade Name
ADVANTECH
Model
ARK-3381; ARK 3382
Housing Type
Metal Case
EUT Power Rating
DCV From Power Adapter
Power Adapter Manufacturer
LE
Power Adapter Power Rating
I/P: 100-240VAC, 50-60Hz
O/P: 12VDC, 4A
AC Power Cord Type
Unshielded, 1.8m (Detachable) to Power Adapter
DC Power Cable Type
Unshielded, 1.8m (Non-detachable) with a core at
Power Adapter
HDD Manufacturer
Fujitsu
Model MHT2040AT
Mother Board Manufacturer
ADVANTECH
Model PCM-9300
CPU Manufacturer
Intel
Model 1.1GHz
Memory Capacity
512MB
Model LE-9702B
For ARK-3381
For ARK-3382
CPU Manufacturer
Intel
Memory Capacity
384MB
Model 1.4GHz
Page 4
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
I/O Port of EUT (For ARK-3381)
I/O Port Type
Date of Issue: May 4, 2005
Q’TY
TESTED WITH
1. Serial Port
7
7
2. PS/2 Keyboard Port
1
1
3. Video Out Port (VGA)
1
1
4. LVDS Port
1
1
5. LAN Port
1
1
6. USB Port
1
1
Q’TY
TESTED WITH
1. Serial Port
2
2
2. PS/2 Keyboard Port
1
1
3. Video Out Port (VGA)
1
1
4. LVDS Port
1
1
5. LAN Port
4
4
6. USB Port
1
1
I/O Port of EUT (For ARK 3382)
I/O Port Type
Page 5
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
3 TEST METHODOLOGY
3.1 EUT SYSTEM OPERATION
1.
2.
3.
4.
5.
6.
EMI test software was loaded and executed under “Windows XP” environment.
A communicated software was loaded and executed to communicate between EUT and
remote side.
EUT sends and receives data from Notebook PC on remote side via LAN Cable.
Data was sent to monitor filling the screen with upper case of “H” patterns.
Test program sequentially exercised all related I/O’s of EUT and sent “H” patterns to
all applicable output ports of EUT.
Repeat step 2 to 5
Note: Test program is self-repeating throughout the test.
3.2 DECISION OF FINAL TEST MODE
1. The following test mode(s) were scanned during the preliminary test:
Mode 1
1280 x 1024 Recitation (ARK-3381)
Mode 2
1280 x 1024 Recitation / LAN (ARK 3382)
Mode 3
1024 x 768 Recitation (ARK-3381)
Mode 4
1024 x 768 Recitation (ARK 3382)
Mode 5
800 x 600 Recitation (ARK-3381)
Mode 6
800 x 600 Recitation (ARK 3382)
2. After the preliminary scan, the following test mode was found to produce the highest
emission level.
Mode 1, 2.
Then, the EUT configuration and cable configuration of the above highest emission mode
was recorded for all final test items.
Page 6
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
4 SETUP OF EQUIPMENT UNDER TEST
Setup Diagram
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
Support Equipment
(For ARK-3381)
No.
Equipment
Model No.
Serial No.
FCC ID
Trade Name
Data Cable
1.
Monitor
959NF
AQ19H2RT706122K
FCC DoC
SAMSUNG
Shielded, 1.8m
with two cores
2.
Modem
DM-1414
304012266
IFAXDM1414
ACEEX
Unshielded, 1.5m Unshielded, 1.5m
3.
Modem
DM-1414
304012267
IFAXDM1414
ACEEX
Unshielded, 1.5m Unshielded, 1.5m
4.
Modem
DM-1414
304012268
IFAXDM1414
ACEEX
Unshielded, 1.5m Unshielded, 1.5m
5.
PS/2 Keyboard
SK-2800C
N/A
FCC DoC
COMPAQ
Shielded, 1.5m
N/A
M-S69
N/A
FCC DoC
COMPAQ
Shielded, 1.5m
N/A
6.
(one to two adapter)
PS/2 Mouse
(one to two adapter)
Power Cord
Unshielded, 1.8m
7.
Mouse
M-MM43
LZE95250096
FCC DoC
Logitech
Shielded, 1.5m
N/A
8.
Mouse
M-MM43
LZE93353074
FCC DoC
Logitech
Shielded, 1.5m
N/A
9.
Mouse
M-MM43
LZE94052791
FCC DoC
Logitech
Shielded, 1.5m
N/A
10.
Mouse
M-MM43
LZE94052771
FCC DoC
Logitech
Shielded, 1.5m
N/A
11.
USB 2.0
External HDD
F12-UF
A0100214-43b0001
FCC DoC
TeraSys
Shielded, 1.5m
N/A
12.
Notebook PC
(Remote)
PPT
0932RY
E2K24GBRL
DELL
LAN Cable:
Unshielded, 10m
AC I/P:
Unshielded, 1.8m
DC O/P:
Unshielded, 1.8m
(For ARK 3382)
No.
Equipment
Model No.
Serial No.
FCC ID
Trade Name
Data Cable
1.
Monitor
959NF
AQ19H2RT706122K
FCC DoC
SAMSUNG
Shielded, 1.8m
with two cores
2.
PS/2 Keyboard
SK-2800C
N/A
FCC DoC
COMPAQ
Shielded, 1.5m
N/A
M-S69
N/A
FCC DoC
COMPAQ
Shielded, 1.5m
N/A
3.
(one to two adapter)
PS/2 Mouse
(one to two adapter)
Power Cord
Unshielded, 1.8m
4.
Mouse
M-MM43
LZE95250096
FCC DoC
Logitech
Shielded, 1.5m
N/A
5.
Mouse
M-MM43
LZE93353074
FCC DoC
Logitech
Shielded, 1.5m
N/A
6.
USB 2.0
External HDD
F12-UF
A0100214-43b0001
FCC DoC
TeraSys
Shielded, 1.5m
N/A
7.
HUB
(Remote)
DS104
N/A
FCC DoC
NERGEAR
8.
Notebook PC
(Remote)
PPT
0932RY
E2K24GBRL
DELL
LAN Cable x 4:
Unshielded, 10m
Unshielded, 1.8m
N/A
AC I/P:
Unshielded, 1.8m
DC O/P:
Unshielded, 1.8m
Note: All the above equipment/cables were placed in worse case positions to maximize emission signals during
emission test.
Grounding: Grounding was in accordance with the manufacturer’s requirements and conditions for the intended
use.
Page 7
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
5
Date of Issue: May 4, 2005
FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
CCS Taiwan Linkou Lab at No. 81-1, Lane 210, Bade Rd., 2, Luchu Hsiang, Taoyuan Hsien,
Taiwan.
The measurement facilities are constructed in conformance with the requirements of CISPR
16-1, ANSI C63.4 and other equivalent standards.
Page 8
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
5.2 LABORATORY ACCREDITATIONS AND LISTINGS
The test facilities used to perform Electromagnetic compatibility tests are registered or
accredited by the organizations listed in the following table which includes the recognized
scope specifically.
Country Agency
Scope of Accreditation
USA
NVLAP
EN 55011, EN 55014-1, AS/NZS 1044, CNS
13783-1, EN 55022, CNS 13438, EN 61000-3-2,
EN 61000-3-3, ANSI C63.4, FCC OST/MP-5,
AS/NZS CISPR 22, IEC 61000-4-2, IEC
61000-4-3, IEC 61000-4-4, IEC 61000-4-5,
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
USA
FCC
3/10 meter Open Area Test Sites to perform FCC
Part 15/18 measurements
Logo
93105, 90471
VCCI
3/10 meter Open Area Test Sites and conducted
test sites to perform radiated/conducted
measurements
NEMKO
EN 50081-1/2, EN 50082-1/2, IEC 61000-6-1/2,
EN 50091-2, EN 50130-4, EN 55011, EN 55013,
EN 55014-1/2, EN 55015, EN 55022, EN 55024,
EN 61000-3-2/3, EN 61326-1,
IEC 61000-4-2/3/4/5/6/8/11, EN 60601-1-2,
ELA 124a
EN 300 328-2, EN 300 422-2, EN 301 419-1,
ELA 124b
EN 301 489-01/03/07/08/09/17, EN 301 419-2/3, ELA 124c
EN 300 454-2, EN 301 357-2
Taiwan
CNLA
EN 300 328-1, EN 300 328-2, EN 300 220-1,
EN 300 220-2, EN 300 220-3, 47 CFR FCC Part
15 Subpart C, EN 61000-3-2, EN 61000-3-3,
CNS 13439, CNS 13783-1, CNS 14115,
CNS 13438, AS/NZS CISPR 22, CNS 13022-1,
IEC 61000-4-2/3/4/5/6/8/11, CNS 13022-2/3
Taiwan
BSMI
CNS 13438, CNS 13783-1, CNS 13439,
CNS 14115
Canada
Industry
Canada
RSS212, Issue 1
Japan
Norway
R-393/1066/725/879/1868
C-402/747/912
SL2-IS-E-0014 /
IN-E-0014 /A1-E-0014
/R1-E-0014 /R2-E-0014
/L1-E-0014
IC 3991-3
IC 3991-4
Note: No part of this report may be used to claim or imply product endorsement by CNLA, NVLAP or other
government agency.
Page 9
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
6
Date of Issue: May 4, 2005
INSTRUMENT AND CALIBRATION
6.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and is
traceable under the IEC 17025 to international or national standards. Equipment has been
calibrated by accredited calibration laboratories.
6.2 TEST AND MEASUREMENT EQUIPMENT
The following list contains measurement equipment used for testing. The equipment conforms
to the requirement of CISPR 16-1, ANSI C63.2 and other equivalent standards.
Calibration of all test and measurement, including any accessories that may effect such
calibration, is checked frequently to ensure the accuracy. Adjustments are made and
correction factors are applied in accordance with the instructions contained in the respective
manual.
Equipment Used for Emission Measurement
Conducted Emission Test Site # 4
Name of Equipment
Manufacturer
Model
Serial Number Calibration Due
EMI Test Receiver
R&S
ESCS30
847793/012
12/27/2005
LISN
EMCO
3825/2
9003-1628
07/26/2005
LISN
R&S
ENV 4200
830326/016
03/30/2006
Note: The measurement uncertainty is less than +/- 2.83dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.
Page 10
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Open Area Test Site # 2
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
Spectrum Analyzer
ADVANTEST
R3261A
21720279
N.C.R
EMI Test Receiver
R&S
ESVS10
834468/006
04/06/2006
Pre-Amplifier
HP
8447D
2944A08780
07/14/2005
Bilog Antenna
Sunol Sciences
JB1
A111203
12/24/2005
Turn Table
EMCO
2081-1.21
9709-1885
N.C.R
Antenna Tower
EMCO
2075-2
9707-2060
N.C.R
Controller
EMCO
2090
9709-1256
N.C.R
RF Switch
ANRITSU
MP59B
M76890
N.C.R
Site NSA
CCS
N/A
N/A
08/13/2005
Note: The measurement uncertainty is less than +/- 3.36dB, which is evaluated as per the NAMAS NIS 81 and
CISPR/A/291/CDV.
3 meter Chamber
Name of Equipment
Manufacturer
Model
Serial Number
Calibration Due
Spectrum Analyzer
ADVANTEST
R3271A
85060321
10/15/2005
Pre-Amplifier
HP
8449B
3008A00965
10/14/2005
Horn Antenna
EMCO
3115
9602-4659
04/09/2006
Coaxial Cable
ANOREW
LDF-2-50
79027
10/13/2005
Turn Table
HD
HD320
N/A
N.C.R
Antenna Tower
HD
MA 240
N/A
N.C.R
Controller
HD
HD 100
N/A
N.C.R
Page 11
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
7
Date of Issue: May 4, 2005
LINE CONDUCTED & RADIATED EMISSION TEST
7.1 LIMIT
Maximum permissible level of Line Conducted Emission
Class A (dBuV)
Class B (dBuV)
Frequency
(MHZ)
Quasi-peak
Average
Quasi-peak
Average
0.15 - 0.5
79
66
66 - 56
56 - 46
0.50 - 5.0
73
60
56
46
5.0 - 30.0
73
60
60
50
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 10 meter
Frequency
(MHZ)
Class A (dBuV/m)
Class B (dBuV/m)
Quasi-peak
Quasi-peak
30 – 230
40
30
230 - 1000
47
37
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 3 meter
Class A (dBuV/m)
Class B (dBuV/m)
Frequency
(MHZ)
Average
Peak
Average
Peak
Above 1000
59.3
79.3
53.9
73.9
Note: The lower limit shall apply at the transition frequency.
Page 12
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
7.2 TEST PROCEDURE OF LINE CONDUCTED EMISSION
Procedure of Preliminary Test
The EUT was set up as per the test configuration to simulate typical usage per the user’s
manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is
used and is placed on the ground plane as per ANSI C63.4 (see Test Facility for the
dimensions of the ground plane used). When the EUT is a floor-standing equipment, it is
placed on the ground plane which has a 3-12 mm non-conductive covering to insulate the
EUT from the ground plane.
Support equipment, if needed, was placed as per ANSI C63.4.
All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
The test equipment EUT installed received AC power, 120VAC/60Hz, through a Line
Impedance Stabilization Network (LISN), which supplied power source and was grounded
to the ground plane.
All support equipment received power from a second LISN.
The EUT test program was started. Emissions were measured on each current carrying
line of the EUT using a EMI Test Receiver connected to the LISN powering the EUT. The
LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two
scans were taken: one with Line 1 connected to the Receiver and Line 2 connected to a 50
ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to
the Receiver.
The Receiver scanned from 150kHz to 30MHz for emissions in each of the test modes.
During the above scans, the emissions were maximized by cable manipulation.
The test mode(s) described in Item 3.2 were scanned during the preliminary test.
After the preliminary scan, we found the test mode described in Item 3.2 producing the
highest emission level.
The EUT configuration and cable configuration of the above highest emission level were
recorded for reference of the final test.
Page 13
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Procedure of Final Test
EUT and support equipment were set up on the test bench as per step 10 of the preliminary
test.
A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
emissions. Emission frequency and amplitude were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit. If EUT emission level was less –2dB to the AV. limit in Q.P. mode, then
the emission signal was re-checked using an AV. detector.
The test data of the worst-case condition(s) was recorded.
Data Sample:
Freq.
(MHz)
Q.P.
Raw
(dBuV)
Average
Raw
(dBuV)
Q.P.
Limit
(dBuV)
Average
Limit
(dBuV)
Q.P.
Margin
(dB)
Average
Margin
(dB)
Note
x.xx
43.95
---
73.00
60.00
-29.05
---
L1
Freq.
Raw dBuV
Limit dBuV
Margin dB
Note
“---“
= Emission frequency in MHz
= Uncorrected Analyzer/Receiver reading + Insertion loss of LISN, if it > 0.5 dB
= Limit stated in standard
= Reading in reference to limit
= Current carrying line of reading
= The emission level complied with the Average limits, with at least 2dB margin
limits, so no further recheck.
Calculation Formula
Margin (dB) = RAW (dBuV) – Limit (dBuV)
Page 14
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
7.3 TEST PROCEDURE OF RADIATED EMISSION
Procedure of Preliminary Test
The equipment was set up as per the test configuration to simulate typical usage per the
user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of
0.8 meters is used which is placed on the ground plane. When the EUT is a floor-standing
equipment, it is placed on the ground plane which has a 3-12 mm non-conductive
covering to insulate the EUT from the ground plane.
Support equipment, if needed, was placed as per ANSI C63.4.
All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
The EUT received AC power source, 120VAC/60Hz, from the outlet socket under the
turntable. All support equipment received power from another socket under the turntable.
The antenna was placed at 10 meter away from the EUT as stated in ANSI C63.4. The
antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier
would be used.
The Analyzer / Receiver quickly scanned from 30MHz to 40GHz maximum, if any. The
EUT test program was started. Emissions were scanned and measured rotating the EUT to
360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the
vertical and the horizontal polarization, to maximize the emission reading level.
The test mode(s) described in Item 3.2 were scanned during the preliminary test:
After the preliminary scan, we found the test mode described in Item 3.2 producing the
highest emission level.
The EUT and cable configuration, antenna position, polarization and turntable position of
the above highest emission level were recorded for the final test.
Page 15
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Procedure of Final Test
EUT and support equipment were set up on the turntable as per step 8 of the preliminary
test.
The Analyzer / Receiver scanned from 30MHz to 40GHz maximum, if any. Emissions
were scanned and measured rotating the EUT to 360 degrees, varying cable placement and
positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the
horizontal polarization, to maximize the emission reading level.
Recorded at least the six highest emissions. Emission frequency, amplitude, antenna
position, polarization and turntable position were recorded into a computer in which
correction factors were used to calculate the emission level and compare reading to the
applicable limit and only Q.P. reading is presented.
The test data of the worst case condition(s) was recorded.
Data Sample:
Freq.
(MHz)
Raw
Data
(dBuV)
Corr.
Factor
(dB/m)
Emiss.
Level
(dBuV/m)
Limits
(dBuV/m)
Margin
(dB)
xx.xx
14.00
12.20
26.20
40.00
-13.80
Freq.
Raw Data (dBuV)
Corr. Factor (dB/m)
Emiss. Level (dBuV/m)
Limit (dBuV/m)
Margin (dB)
P
Q
A
= Emission frequency in MHz
= Uncorrected Analyzer / Receiver reading
= Antenna factor + Cable loss – Amplifier gain
= Raw reading converted to dBuV/m and CF added
= Limit stated in standard
= Reading in reference to limit
= Peak Reading
= Quasi-peak Reading
= Average Reading
Calculation Formula
Margin (dB) = Emiss. Level (dBuV/m) – Limits (dBuV/m)
Emission Level (dBuV/m) = Raw Data (dBuV) + Corr Factor (dB/m)
Page 16
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
7.4 TEST RESULTS
Line Conducted Emission
Model: ARK-3381
Test Mode: Mode 1
Temperature: 25°C
Humidity: 58% RH
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
8.081
Q.P.
Raw
(dBuV)
31.50
AVG
Raw
(dBuV)
---
Q.P.
Limit
(dBuV)
73.00
AVG
Limit
(dBuV)
60.00
Q.P.
Margin
(dB)
-41.50
AVG
Margin
(dB)
---
8.593
31.40
---
73.00
60.00
-41.60
---
L1
11.102
29.80
---
73.00
60.00
-43.20
---
L1
13.091
30.10
---
73.00
60.00
-42.90
---
L1
13.549
30.40
---
73.00
60.00
-42.60
---
L1
15.028
28.60
---
73.00
60.00
-44.40
---
L1
8.211
29.70
---
73.00
60.00
-43.30
---
L2
8.719
28.50
---
73.00
60.00
-44.50
---
L2
10.639
29.00
---
73.00
60.00
-44.00
---
L2
13.013
27.10
---
73.00
60.00
-45.90
---
L2
13.401
28.40
---
73.00
60.00
-44.60
---
L2
14.748
27.50
---
73.00
60.00
-45.50
---
L2
Freq.
(MHz)
NOTE
L1
L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Note: “---” denotes the emission level was or more than 2dB below the Average limit, so no re-check anymore.
Page 17
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Line Conducted Emission
Model: ARK 3382
Test Mode: Mode 2
Temperature: 28°C
Humidity: 59% RH
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
3.329
Q.P.
Raw
(dBuV)
38.80
AVG
Raw
(dBuV)
---
Q.P.
Limit
(dBuV)
73.00
AVG
Limit
(dBuV)
60.00
Q.P.
Margin
(dB)
-34.20
AVG
Margin
(dB)
---
3.958
37.30
---
73.00
60.00
-35.70
---
L1
5.451
31.50
---
73.00
60.00
-41.50
---
L1
8.082
32.60
---
73.00
60.00
-40.40
---
L1
8.589
30.10
---
73.00
60.00
-42.90
---
L1
11.101
30.70
---
73.00
60.00
-42.30
---
L1
2.982
39.40
---
73.00
60.00
-33.60
---
L2
4.009
37.60
---
73.00
60.00
-35.40
---
L2
5.443
34.30
---
73.00
60.00
-38.70
---
L2
7.161
27.90
---
73.00
60.00
-45.10
---
L2
9.962
26.50
---
73.00
60.00
-46.50
---
L2
10.130
25.20
---
73.00
60.00
-47.80
---
L2
Freq.
(MHz)
NOTE
L1
L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Note: “---” denotes the emission level was or more than 2dB below the Average limit, so no re-check anymore.
Page 18
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission (A)
Model: ARK-3381
Test Mode: Mode 1
Temperature: 23°C
Humidity: 56% RH
Detector Function: Quasi-peak.
Antenna: Vertical at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
=================================================================
Freq.
Raw
Corr.
Emiss.
Limits
Margin
Data
Factor
Level
(MHz)
(dBuV)
(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
=================================================================
108.13
25.5
13.4
38.9
40.0
-2.4
------------------------------------------------------------------------------------------------------------147.58
18.9
15.1
34.0
40.0
-6.0
------------------------------------------------------------------------------------------------------------153.86
20.8
14.7
35.5
40.0
-4.5
------------------------------------------------------------------------------------------------------------162.36
11.3
14.3
25.6
40.0
-14.4
------------------------------------------------------------------------------------------------------------378.00
26.0
18.5
44.5
47.0
-2.5
------------------------------------------------------------------------------------------------------------540.15
15.8
22.7
38.5
47.0
-8.5
------------------------------------------------------------------------------------------------------------648.21
14.8
24.4
39.2
47.0
-7.8
------------------------------------------------------------------------------------------------------------702.20
17.1
25.0
42.1
47.0
-4.9
------------------------------------------------------------------------------------------------------------756.19
17.4
25.4
42.8
47.0
-4.2
------------------------------------------------------------------------------------------------------------810.24
15.5
27.5
43.0
47.0
-4.0
------------------------------------------------------------------------------------------------------------864.31
15.0
27.1
42.1
47.0
-4.9
------------------------------------------------------------------------------------------------------------918.14
12.6
28.0
40.6
47.0
-6.4
------------------------------------------------------------------------------------------------------------972.14
15.1
28.8
43.9
47.0
-3.1
-------------------------------------------------------------------------------------------------------------
Page 19
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission (B)
Model: ARK-3381
Test Mode: Mode 1
Temperature: 23°C
Humidity: 56% RH
Detector Function: Quasi-peak.
Antenna: Horizontal at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
=================================================================
Freq.
Raw
Corr.
Emiss.
Limits
Margin
Data
Factor
Level
(MHz)
(dBuV)
(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
=================================================================
108.06
22.8
13.4
36.2
40.0
-3.8
------------------------------------------------------------------------------------------------------------144.10
21.0
15.3
36.3
40.0
-3.7
------------------------------------------------------------------------------------------------------------162.05
25.3
14.3
39.6
40.0
-2.4
------------------------------------------------------------------------------------------------------------216.01
25.7
14.1
39.8
40.0
-2.1
------------------------------------------------------------------------------------------------------------378.07
26.0
18.5
44.5
47.0
-2.5
------------------------------------------------------------------------------------------------------------399.81
11.9
18.8
30.7
47.0
-16.3
------------------------------------------------------------------------------------------------------------410.60
13.7
19.1
32.8
47.0
-14.2
------------------------------------------------------------------------------------------------------------432.26
12.9
19.8
32.7
47.0
-14.3
------------------------------------------------------------------------------------------------------------487.26
14.0
21.3
35.3
47.0
-11.7
------------------------------------------------------------------------------------------------------------864.27
15.6
27.1
42.7
47.0
-4.3
------------------------------------------------------------------------------------------------------------918.31
13.4
28.0
41.4
47.0
-5.6
------------------------------------------------------------------------------------------------------------972.33
9.0
28.8
37.8
47.0
-9.2
-------------------------------------------------------------------------------------------------------------
Page 20
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission (A)
Model: ARK 3382
Test Mode: Mode 2
Temperature: 23°C
Humidity: 56% RH
Detector Function: Quasi-peak.
Antenna: Vertical at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
=================================================================
Freq.
Raw
Corr.
Emiss.
Limits
Margin
Data
Factor
Level
(MHz)
(dBuV)
(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
=================================================================
108.05
24.7
13.4
38.1
40.0
-1.9
------------------------------------------------------------------------------------------------------------162.02
23.4
14.3
37.7
40.0
-2.3
------------------------------------------------------------------------------------------------------------171.84
23.7
14.1
37.8
40.0
-2.2
------------------------------------------------------------------------------------------------------------199.35
22.8
14.7
37.5
40.0
-2.5
------------------------------------------------------------------------------------------------------------365.56
20.3
18.4
38.7
47.0
-8.3
------------------------------------------------------------------------------------------------------------498.57
23.0
21.7
44.7
47.0
-2.3
------------------------------------------------------------------------------------------------------------697.91
16.2
25.0
41.2
47.0
-5.8
------------------------------------------------------------------------------------------------------------756.29
13.4
25.4
38.8
47.0
-8.2
------------------------------------------------------------------------------------------------------------797.54
13.7
27.5
41.2
47.0
-5.8
------------------------------------------------------------------------------------------------------------816.27
9.2
27.4
36.6
47.0
-10.4
------------------------------------------------------------------------------------------------------------996.90
8.1
29.1
37.2
47.0
-9.8
-------------------------------------------------------------------------------------------------------------
Page 21
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission (B)
Model: ARK 3382
Test Mode: Mode 2
Temperature: 23°C
Humidity: 56% RH
Detector Function: Quasi-peak.
Antenna: Horizontal at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
=================================================================
Freq.
Raw
Corr.
Emiss.
Limits
Margin
Data
Factor
Level
(MHz)
(dBuV)
(dB/m)
(dBuV/m)
(dBuV/m)
(dB)
=================================================================
332.44
22.2
17.4
39.6
47.0
-7.4
------------------------------------------------------------------------------------------------------------365.66
19.9
18.4
38.3
47.0
-8.7
------------------------------------------------------------------------------------------------------------432.66
24.0
19.8
43.8
47.0
-3.2
------------------------------------------------------------------------------------------------------------487.25
21.8
21.3
43.1
47.0
-3.9
------------------------------------------------------------------------------------------------------------498.47
18.4
21.7
40.1
47.0
-6.9
------------------------------------------------------------------------------------------------------------564.97
9.6
23.0
32.6
47.0
-14.4
------------------------------------------------------------------------------------------------------------631.02
18.2
24.0
42.2
47.0
-4.8
------------------------------------------------------------------------------------------------------------668.02
15.4
24.6
40.0
47.0
-7.0
------------------------------------------------------------------------------------------------------------972.02
11.8
28.8
40.6
47.0
-6.4
-------------------------------------------------------------------------------------------------------------
Page 22
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission – Above 1GHz (A)
Model: ARK-3381
Test Mode: Mode 1
Temperature: 23°C
Humidity: 56% RH
Detector Function: Pk/ A.V.
Antenna: Vertical at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
E m iss. L evel
L im it 3m
R aw
C o rr.
F req.
(P k)
(P k)
D ata
F actor
(M H z)
(dB uV /m )
(dB uV /m )
(dB uV )
(dB /m )
M arg in
(dB )
3483.33
40.84
0.32
41 .16
79.30
-3 8.14
4191.67
40.17
2.64
42 .81
79.30
-3 6.49
5500.00
39.50
4.73
44 .23
79.30
-3 5.07
6600.00
41.00
5.71
46 .71
79.30
-3 2.59
7175.00
39.67
7.00
46 .67
79.30
-3 2.63
7558.33
40.17
7.87
48 .04
79.30
-3 1.26
Note: In case of peak reading complied with the limit at least 22dB margin, no measurement with A.V. detector
required.
Page 23
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission – Above 1GHz (B)
Model: ARK-3381
Test Mode: Mode 1
Temperature: 23°C
Humidity: 56% RH
Detector Function: Pk/ A.V.
Antenna: Horizontal at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
E m iss. L evel
L im it 3m
R aw
C o rr.
F req.
(P k)
(P k)
D ata
F actor
(M H z)
(dB uV /m )
(dB uV /m )
(dB uV )
(dB /m )
M arg in
(dB )
2896.67
41.17
-1.71
39 .46
79.30
-3 9.84
3908.33
39.00
2.24
41 .24
79.30
-3 8.06
4541.67
40.17
2.68
42 .85
79.30
-3 6.45
5408.33
39.34
4.53
43 .87
79.30
-3 5.43
6508.33
39.17
5.51
44 .68
79.30
-3 4.62
7675.00
39.84
8.00
47 .84
79.30
-3 1.46
Note: In case of peak reading complied with the limit at least 22dB margin, no measurement with A.V. detector
required.
Page 24
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission – Above 1GHz (A)
Model: ARK 3382
Test Mode: Mode 2
Temperature: 23°C
Humidity: 56% RH
Detector Function: Pk/ A.V.
Antenna: Vertical at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
E m iss. L evel
L im it 3m
R aw
C o rr.
F req.
(P k)
(P k)
D ata
F actor
(M H z)
(dB uV /m )
(dB uV /m )
(dB uV )
(dB /m )
M arg in
(dB )
1833.33
48.67
-5.51
43 .16
79.30
-3 6.14
4083.33
39.50
2.65
42 .15
79.30
-3 7.15
5200.00
38.84
4.09
42 .93
79.30
-3 6.37
5391.67
39.50
4.50
44 .00
79.30
-3 5.30
6650.00
39.84
5.82
45 .66
79.30
-3 3.64
7650.00
40.17
7.97
48 .14
79.30
-3 1.16
Note: In case of peak reading complied with the limit at least 22dB margin, no measurement with A.V. detector
required.
Page 25
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Radiated Emission – Above 1GHz (B)
Model: ARK 3382
Test Mode: Mode 2
Temperature: 23°C
Humidity: 56% RH
Detector Function: Pk/ A.V.
Antenna: Horizontal at 10m
Tested by: Carl Chang
Test Results: Pass
(The chart below shows the highest readings taken from the final data)
E m iss. L evel
L im it 3m
R aw
C o rr.
F req.
(P k)
(P k)
D ata
F actor
(M H z)
(dB uV /m )
(dB uV /m )
(dB uV )
(dB /m )
M arg in
(dB )
3700.00
40.00
1.29
41 .29
79.30
-3 8.01
3916.67
40.00
2.28
42 .28
79.30
-3 7.02
4175.00
40.34
2.64
42 .98
79.30
-3 6.32
4866.67
39.84
3.38
43 .22
79.30
-3 6.08
6116.67
40.00
5.27
45 .27
79.30
-3 4.03
7675.00
39.67
8.00
47 .67
79.30
-3 1.63
Note: In case of peak reading complied with the limit at least 22dB margin, no measurement with A.V. detector
required.
Page 26
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
APPENDIX 1 - PHOTOGRAPHS OF TEST SETUP
LINE CONDUCTED EMISSION TEST
Mode 1
Page 27
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Mode 2
Page 28
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
RADIATED EMISSION TEST
Mode 1
Page 29
Rev. 00
Compliance Certification Services Inc.
Report No.: 50304118-F
Date of Issue: May 4, 2005
Mode 2
Page 30
Rev. 00
Download PDF