accessories catalog - Romquest Technologies Corp.

CONTENTS
Computer software Checkweigher SWD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Computer software Pipettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Computer software E2R System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Computer software PW WIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Computer software REC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Computer software RAD KEY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Computer software KTP NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Computer software OWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Computer software LS-FS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Computer software AF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Computer software SNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Kafka thermal printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Epson needle printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Citizen label printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table for scale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Anti vibration table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Professional weighing table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Foot tare and print buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Set for determination of water vapour permeability . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Density determination kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Rack for under hook weighing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Anti draught shield for microbalances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Anti draught shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Anti dust shield for printers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Cereals density determination kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Control thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Stand for measuring indicator WPT4.XX H50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Handle for measuring indicator in plastic version PUE1-3-02 . . . . . . . . . . . . . . . . . . . . . 37
Lcd display in plastic casing WD-4/1 and WD-3/01. . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Lcd display in stainless steel casing WD-4/2 and WD-4/3 . . . . . . . . . . . . . . . . . . . . . . . 39
Large lcd display WWG-2 (digit height 4,5 inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Ultrasonic air ionizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Power adapter with battery and charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Suitcase for balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Roller table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Ramps for low profiled scales. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Bar code scanner
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Transponder card reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Converter RS232/RS485 KR-01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Converter RS232/ETHERNET KR-04 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Module in/out PP-01 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Power loop output AP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
CHECKWEIGHER SWD computer software
Product description:
The program is intended to collect both partial weighing
procedures and packed product control complete reports
from Radwag checkweighers.
The application can serve many balances at the same
time, enabling automatic segregating and saving loaded
weighing procedures in separate databases. It also
enables reports generating and exporting data to text
format.
Designed for scales:
dynamic/control, based on TMC head
Functions:
servicing many balances at the same time
program operating in automatic or manual mode, measurements collecting
from balance heads and sending them to local databases
collected measurements segregating inside database (MS Access), giving
consideration to time and measurement category
measurements (databases) exporting to CSV text format, with semicolon
as records separator
communication servicing through port RS-232 and Ethernet (TCP)
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
Language versions:
Polish, English, Russian.
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
Pipettes computer software
Product description:
Computer Software PIPETY is designed for the determination
of volume measurement errors of pipettes (batchers)
in accordance with the standard ISO 8655.
Designed for scales:
XA/X, XA/Y, MYA/P
Functions:
calculating results on the basis of:
average volume of a pipette ( channel)
systematic error es ( accuracy error A)
random error CV (repeatability error)
calibration of constant volume pipettes (single channel) and variable volume pipettes
(1, 8, 12 channel)
automatic measuring procedures depending on the type of tested pipette
information on pipettes are stored in the data base (option of defining your own models)
storing calibration results in MS Access data bases
back-up of databases, including calibration results
print-outs of pipette calibration protocols
exporting test reports to PDF, MS Word, Excel and other
planning dates of subsequent calibrations
filtering planned pipette calibration: current week or month
cooperation with a balance connected through RS 232 port:
all RADWAG models – based on non-coded communication frame
possibility to connect balances of different manufacturers
option of manual input of weighing values
Computer requirements:
processor INTEL or AMD min 2000 MHz
min 500 MB RAM
SVGA video card
50 GB HDD storage space
Windows XP/2000/Vista or a newer operating system
Microsoft R .NET Framework 2.0
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
E2R EVIDENCE computer software
Product description:
Recording of measurements performed on Radwag
weighing terminals, joined in a web and saved in
computer database. The system is based on database MS
SQL 2000 or MS SQL 2005.
The program is addressed to receivers of various industry
branches: meat, fish food, sugar, chemical and
metallurgy among others.
The program is especially used at places, where products
are weighed, that are not directly connected one to
another by common data and they are not a part of a
weighing process which has its defined beginning and
ending, e.g. transaction or production order.
Designed for scales:
TMC, WPW, equipped with PUE 5 and PUE 7
Functions:
Possibility to add, delete and edit following card files of: products,
operators, contractors, stores, tares (packages)
Monitoring from the level of computer of weighing procedures performed
on weighing terminals
Simplified Reporting Module enabling report generating according to chosen
filters: product's code or name, operator's code or name, contractor's
code or name, date of weighing, lot number, balance number
Possibility to sum up filtered data in form of: total of performed weighing
procedures, number of carried out measurements, performed
measurements' average, minimal weighed mass, maximal weighed mass
Possibility to service large amount of data in real time
Possibility to monitor production process from many places of the firm
house via balances connected in net
Defining access levels for individual users
Possibility to extend program functionality with additional modules: E2R
Transactions, E2R Formulations, E2R Weighing procedures, E2R Reports
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
E2R RECIPES computer software
Product description:
Chosen formulation's components weighing according to
production order, formulations' defining with possibility
to declare certain component's tolerance range. The
system is based on database MS SQL 2000 or MS SQL
2005.
The program is addressed to receivers of various industry
branches, like:
-building,
-food,
-sugar,
-chemical,
-metallurgical.
Designed for scales:
TMC, equipped with PUE 5 and PUE 7
Functions:
Possibility to add, delete and edit following card files of:
products, stores, operators, tares, contractors, formulations
Monitoring of weighing procedures performed on weighing terminals
containing simplified Reporting Module. Possibility of report generating
according to: product's code or name, operator's code or name,
formulation's code or name, order's code or name, date of weighing,
lot number, balance number
Possibility to sum up filtered data in form of: total of weighed component
masses, number of certain component measurements, weighed component
measurements' average, minimal mass of weighed component, maximal
mass of weighed component
Possibility to define weighed amounts for individual components of
a formulation
Possibility to fix weighed component's tolerance
Formulation's weighing up to defined mass
Store management service
Cooperating with Data Synchronization Module
Production orders service
Defining access levels for individual users
Possibility to extend program functionality with additional module:
E2R Reports
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
E2R TRANSACTIONS computer software
Product description:
The module enables recording of measurements
performed on weighing terminals joined in net. The
measurements can be imported or exported to external
accountancy or production managing programs. The
system is based on database MS SQL 2000 or MS SQL
2005.
The program is addressed to receivers of various industry
branches: meat, fish food, sugar, chemical and
metallurgy among others.
The program is intended for companies, where weighing
process is based on transactions or production orders,
where it is necessary to monitor product flow, doublesided data exchange with accountancy programs,
production settlement.
Designed for scales:
TMC, WPW, equipped with PUE 5 and PUE 7
Functions:
Possibility to add, delete and edit following card files of:
products, operators, contractors, stores, tares (packages)
Monitoring from the level of computer of weighing procedures performed
on weighing terminals
Simplified Reporting Module enabling report generating according to chosen
filters: product's code or name, operator's code or name, contractor's
code or name, order's code or name, transaction's code or name,
date of weighing, lot number, balance number
Possibility to sum up filtered data in form of: total of performed weighing
procedures, number of carried out measurements, performed measurements'
average, minimal weighed mass, maximal weighed mass
Possibility to service large amount of data in real time
Servicing of selling, buying, inter-store shift transaction
Production orders servicing
Store management servicing
Cooperation with Data Synchronization Module
Possibility to monitor production process from many places of the firm
house via balances connected in net
Defining access levels for individual users
Possibility to extend program functionality with additional modules:
E2R Weighing procedures, E2R Reports
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
E2R WEIGHTINGS computer software
Product description:
Recording of measurements performed on weighing
terminals assigned for “+/“ quick control, which helps
limiting operator's role to minimum. The system is based
on database MS SQL 2000 or MS SQL 2005.
The program is addressed to receivers of various industry
branches, e.g.:
-fish,
-food,
-sugar,
-chemical.
Designed for scales:
WPW, equipped with PUE 7
Functions:
Possibility to add, delete and edit following card files of:
products, operators, stores
Monitoring of weighing procedures and performed production orders
from optional point of the factory web, taking into consideration weighing
procedures of individual operating standing
Possibility to sum up performed production orders with single standing
division, in form of: total of performed weighing procedures, number
of performed measurements, average of performed measurements,
minimal weighed mass, maximal weighed mass
Monitoring of performed production orders from the level of the application
by use of simplified Reporting Module
„+/-” quick control balances servicing
Cooperation with Data Synchronization Module
Production orders servicing
Store management servicing
Individual users access levels defining
Possibility to extend program functionality by E2R Reports
additional module
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
E2R REPORTS computer software
Product description:
Large extend of generating reports and statistics of
weighing procedures saved in program E2R System
database. The system is based on MS SQL 2000 or MS
SQL 2005 database.
Designed for scales:
E2R Evidence, E2R Transactions, E2R Formulations, E2R Weighing procedures
Functions:
Possibility to create following reports:
Lot report, worker's working time report, worker's work performance report,
production order report, production line report
Possibility to create special reports fulfilling customer's wish, according
to individual calculation
Possibility to use E2R Reports module in following applications:
E2R File, E2R Transactions, E2R Formulation, E2R Weighing procedures
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
PW-WIN 2004 computer software
Product description:
PW-WIN software is designed for collecting measurement
data from RADWAG weighing instruments and its
statistics process.
Designed for scales:
with standard communication frame
Functions:
readout from instrument, record from measurements and saving data to a file
possibility of manual and automatic registration of measurements
registration and storing of measurement data in a form of file
visualization of measurements data in a form of graph
static processing of measurement data
possibility of creating data from chosen measuring session
printout of measuring data, graphs and statistics
mainlyt used in laboratories
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
Language versions:
Polish, German, English, French.
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
REC-FS 2000 computer software
Product description:
The software is designed for creating recipes
for measured mixtures with possibility of declaring
the tolerance field for particular ingredient
and measuring each ingredient in the receipt.
Designed for scales:
with standard communication frame
Functions:
base for recipes and materials in the software
performing the weighing of recipes
creating reports from performed measurements
measuring a recipe for particular ingredient
measuring a recipe to determined mass
reporting of an indication of material consumption
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
REC-NET 2005 computer software
Product description:
The software allows for performing measurements
the ingredients of a particular recipe and creation
of recipes from measured ingredients. Additionally,
it is possible to declare the tolerance field for chosen
ingredient.
Designed for scales:
interactive terminals: TMC, HX
Functions:
data base of recipes, orders, materials and operators in the computer
with the software
adding, deleting and edit mode of recipes
possibility of defining the side of measured masses for each ingredient
of the recipe
possibility of setting tolerance for measured ingredient
performance of measuring recipes
creation of reports from performed measurements
measuring a recipe for defined material
measuring a recipe for defined mass
weighing instrument connected to computer in on-line
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
RAD-KEY 2000 computer software
Product description:
A software for communication between a computer in PC
class and standard Radwag weighing instruments. Main
subject of the software is collecting the information on
mass indicated by an instrument. The communication
with the computer is realized through RS 232 interface.
Designed for scales:
with standard communication frame
Functions:
collecting data from measurements and saving them into a file
different ways of initializing the process of collecting data from an instrument
to a computer (by a button in an instrument or computer keyboard)
reading of transmission bits by RS 232 interface into a computer and placing
the bits in place of cursor in the computer.
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
Language versions:
Polish, Czech, German, English, French.
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
KTP-NET 2003 computer software
Product description:
Software KTP-NET/N/2003 or KTP-NET/S/2003 is designed
for collection of measurements from RADWAG weighing
instruments connection in net. The net can be composed
from one or a few kinds of weighing instruments.
The start of operation can be done from level of scale
of from the computer software, and finished automatically
after checking of proper quantity of packages.
Basing on the collected data, it is possible to perform
the evaluation of the manufactured packaged goods
for compatibility with:
internal quality management system of the factory
regulation of the Notice of Manager of Main
Measuring Office
Designed for scales:
WPX
WTX
Interactive terminals: TMC, HX
Functions:
software allows for performance of two kids ofcontrol:
according to regulation “On packaged Goods”
internal, i.e. modified for:
size of batch
control time
minus value of T error
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
Functions:
plus vlue of T error
factor for calculation of acceptable average value
means of finishing control, if:
ruqired quantity is reached
required time of control is reached
required time of control or required quantity of batch is reached
required time of control and required quantity of batc is reached
possibility of starting the control in three different ways:
control begun by the operator of the weighing instrument, by sending
the information on start of control to computer software
control is begun by the operator from computer software level, by indication
of weighing instrument number on which the control will run
control takes place from the data base of the software by random choice
of weighing for detailed good.
automation of control process
control of opereator's errors
possibility of operation of dual-platform weighing instruments
with TMC terminal
automatic printout of report after finishing control
defining the access levels to software functions
printout of reports from control
printout of statistics
view of reports and statistics from any place in company net
possibility of running control according to one of chosen algorithms:
control with average tare
control with changeable tare
full empty destructive control
full empty non-destructive control
empty full destructive control
full empty non-destructive control
control of packaging mass - tare
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
OWS 2005 computer software
Product description:
This software cooperates with weighbridges manufactured
by 'RADWAG'. It is a part of weighing system, which is
a supplement of our weighbridges, due to which the whole
process of weighing vehicles is easier and takes much
shorter time.
Designed for scales:
terminal TMC
Functions:
readout of data from scale and registration of results in the software
registration of measurement data in a form of a file
running random quantity of measurements
printing the weighing tickets
generation of reports from measurements
data base of drivers, operators, materials and contractors
registration of control measurements
possibility of cooperation with barriers system and lights system
possibility of cooperation with camera system for recording the situation on the scale
cooperation with system controlling the wastes
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
LS-FS 2000 computer software
Product description:
Software is used to view the quantity of pieces of
measured assortment in real time.
Designed for scales:
WPT
with standard communication frame (e.g.: + 1.350 g)
Functions:
counting pieces for a chosen material
pinting the results of measurements
data base of: materials, packages, operators and contractors
possibility of choosing a label for measured assortment
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
AF 2005 computer software
Product description:
The software determines the percent of content of
determined fractions (e.g. dimension of grains) in
a sample.
Designed for scales:
terminal TMC
Functions:
defining the fractions
data base on users and sieves
definitions of analyses
weighing of each fraction
percent analysis of content of each fraction
generating reports from measurements and from their analysis
readout of measurements and their record
record of measurement data in a form of a file from balance of measurements
registration of control of measurements
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
SNC 2005 computer software
Product description:
COM software is designed for collecting of weighings
from RADWAG weighing instruments. It enables
generating reports with extended filtering mechanism
and weighings placed in computer data base.
Designed for scales:
with standard communication frame
Functions:
operating up to 4 scales with 5 -button indicator, plugged in to local RS-232
computer ports
collecting weighings from individual scales using Print button on indicator
for each weight measurement assigning goods name and weigh operator
for each good possibility of assigning mass threshold: lower and upper
real time weighing results displayed individual for each scale
generating reports for individual scales with possibility of filtering, printing, exporting
and deleting filtered weighings
Computer requirements:
processor 1,2 GHz
free 500 MB on hard drive
RAM 256 MB (reccommended 512 MB)
operation system Windows 2000/XP
* NOTE! RADWAG does not sell software "in box". Boxes presented on our Web-site are of virtual characteristic only, and they are not accessible with purchased software. The customer
receives purchased software on a CD in special protective cover and the user manual as a brochure.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
PRINTERS "KAFKA"
Printer "Kafka" enables two-way thermal printing by mobile
head. The design of the mark: matrix 8 × 8 points. Print
Speed: 0.75 line / sec.
Depending on the version, Kafka can be equipped with real
time clock, statistic functions or internal battery (outdoor
operation).
Specification:
KAFKA 1/RG
KAFKA 1/Z/RG
base functions,
(main current supply)
clock of real time,
(main current supply)
KAFKA 1/RG Portable
KAFKA 1/Z/RG Portable
base functions,
clock of real time,
(battery power and main current supply) (battery power and main current supply)
KAFKA SQS
date, time and statistic functions,
(main current supply)
Print
Dual direction thermal print with moveable 8-point head, character constructio: 8 x 8 point matrix,
print speed: 0,75 line/s, quantity of signs a line: 40, 80
One from below mentioned:
Set of characters
IBM set 2, Mazovia, DHN, Latin-2 PC, Cyrylics, Latin-2 ISO
Thermal paper
Roll: width 112 mm, max diameter 42 mm, paper length 20 m, marking: TF 50KS-E2C
Power supply
8,5V - 14V DC or 7V - 10V AC 50Hz, power consumption: 3W - 15W (max.),
Power connection: type Jack 2.1, external power adapter: 220V / 9V AC 1,5A 50 Hz or battery (portable version)
Interface
One from below mentioned:
RS232C, RS242 (TTL), RS422A (RS485), power loop 20mA (CL), interface connection: 5 pin type DIN
Speed of transmission: 1200, 2400, 4800, 9600 bod (other for secial order.), transmission protocol: machine with DTR,
Transmission parameters
Data format: 8 or 7 bytes, with or without parity control, parity: even or odd
MTBF: 5000 hours, MCBF: 500 000 lines
Durability
Working temperature: 5°C to 35°C, relative humidity: 10% - 80% (no condensation)
Working conditions
165 x 140 x 50 mm, 0,45 kg (without paper roll)
Masses nad dimensions
KAFKA IBM set 2, KAFKA 1 WIN 1250, KAFKA 2 DHN, KAFKA 3 Latin - 2 PC,
Printer marking with set of characters
KAFKA 4 Cyrylica, KAFKA 5 Latin - 2 ISO
printer, external power adapter, interface plug or cable (according to order),
Components
roll of thermal paper, user manual, warranty and external power adapter (portable version)
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
PRINTERS "EPSON"
Specification:
TM-U220A
with paper roll reeler and paper cutter
Means of print
Fonts
Quantity of characters in one line
Character dimensions (mm)
Quantity of charatcters per inch
Interfaces
Input buffer
Mamory for logo
User defined memory
Print speed
Paper width
Paper roll diameter
Colouring tape
Paper cuttet
Power consumption
Power adapter
Casette drawers
Durability
Dimensions
Weight
Colours
Standard functions
Options
Standard EMI
Safety standards
TM-U220B
TM-U220D
with paper cutter
basic version
9-needle
7 × 9 / 9 × 9 points
paper 76,0 mm: 42/40/35/33 cpl 69,5 mm: 40/36/32/30 cpl 57,5 mm: 33/30/27/25 cpl
1,2 / 1,6 / 1,7 / 1,9 / 2,0(width) x 3,1(height)
17,8 / 16 / 14,5 / 13,3
RS-232 or parallel or USB or Ethernet drive for casette drawers, power adapter connection
1 kB or 40 bytes
128 kB
8 kB
6 lines / second (30 characters / line)
76,0 mm +/- 0.5 69,5 mm +/- 0.5 57,5 mm +/- 0.5
maximally 83 mm
ERC-38 purple, black or red-black
Cutter type "full cut" or "one-point-left cut" built in models type A and B
Stand-by: 2,2 W while printing: 31 W
included (compatible with PS-180)
drive for two casette drawers
MTBF: 180 000 hours MCBF: 18 million lines cutter: 800 000 cuts
160 x 286 x 158 mm
160 × 248 × 139 mm
160 x 248 x 139 mm
2,7 kg
2,5 kg
2,3 kg
white: EPSON cool white or dark grey: EPSON dark grey
paper reeler (type A) paper cutter (type A and B) easy paper exchange type "Drop-in" built in fuction Auto Status Back
paper end sensor, paper end sensor, power adapter
wall hanger (for type B)
customer display DM-D (connected through interface UB-S09)
sign CE, EN55022 class B, EN55024
EN60950
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
PRINTERS "CITIZEN"
Specification:
Print
Head
Print speed
Maximal print width
Mximal print length
Minimal print length
Label width
Material thickness
Material kind
Material recognition
Fonts
CLP 521
thermal
200 dpi
100 mm / sec
104 mm
812 mm
12,7 mm
19 - 118 mm
0,0635 ÷ 0,254 mm
labels, cartoons,
continuous media, folder
overexposure optical
sensor and light reflection
from material
8 vector fonts,
1 half-tome screen
Bar codes
Communication interface
-
Control panel
Input buffer
Memory
Memory extension
MTBF (average operation
time between defects)
Dimensions (w × h × l)
Mass
Options
-
CLP 621
CLP 631
CL-S700
thermal, thermo-transfer
thermal, thermo-transfer
thermal, thermo-transfer
200 dpi
300dpi
200dpi
100 mm / sec
175mm/sec
250mm/sek
104 mm
104 mm
104 mm
812 mm
812 mm
406 mm
12,7 mm
12,7
12,7
19 - 118 mm
12,5 - 118 mm
25,4-118 mm
0,0635 ÷ 0,254 mm
0,0635 ÷ 0,254 mm
0,0635 ÷ 0,254 mm
labels, cartoons,
labels, cartoons,
labels, cartoons,
continuous media, folder
continuous media, folder
continuous media, folder
overexposure optical
overexposure optical sensor
overexposure optical sensor
sensor and light reflection
and light reflection from material,
and light reflection from material,
from material
optional moveable optical sensor
optional moveable optical sensor
8 vector fonts,
1 vector, 8 half-tome screen,
1 vector, 8 half-tome screen,
1 half-tome screen
True Type sensors in standard
True Type sensors in standard
All standard types including: EAN-8, EAN-13, UPC-A, UPC-E, UCC/EAN 128, 3 with 9, 2 with 5,
code 93, 128, Coderbar, Telepen, Zip and dual dimensions: PDF-417,UPS Maxicode, Posnet
Parallel (Centronics) series
Parallel (Centronics) series
RS232C
RS232C, USB 1.1
4 buttons, 4 diodes LED
3 buttons, 2 diodes LED, display LCD
12 kB
8 MB
16 MB
Flash 2 MB memory cards
Flash 4 MB memory cards
printer 1000 km,
printing head 30 km
255 × 480 × 253 mm
224 × 288 × 270 mm
13,5 kg
4,5 kg
Paper cutter, divider, Flash memory card,
Paper cutter, divider,
network input, real time clock
Ethernet, WLAN
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
TABLE FOR SCALE
Table for scale is offered in three dimensions, specially
adjusted for Radwag weighing instruments:
1) standard spacing between the feet 370×370mm, table top
dimensions 410×410mm and feet with diameter 36mm
2) standard spacing between the feet 400×400mm table top
dimensions 500x500mm and feet with diameter 36mm
3) standard spacing between the feet 500×500mm table top
dimensions 600×600mm and feet with diameter 36mm
Basic features :
Possibility of adjusting height of the table in range +/- 50mm
By proper screwing of the table feet.
100
(85)
650 ± 50*
10
Specification:
Manufactured in stainless steel technology
Height : 650 +/-50mm
480-610
50
480-610
*-adjustable table height
by screwing feet
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ANTIVIBRATION TABLE
Anti vibration table can be used with as a base for analytical,
laboratory or control balance. It has been designed for
assurance of stable operation conditions while performing
very accurate measurements.
The table is equipped with its own base and is furnished with
MDF painted table top, with a hole for marble board which is
the stabilization part of the table. The construction of the
table is made of mild steel profiles and feet with thread for
adjusting height. The marble board is positioned on an
independent base (for improvement of stable operation of
the weighing instrument). Parts of the table are also offered
in stainless steel and acid-proof construction, and the
dimensions of the table can be separately adjusted to the
customer’s requirements.
wersja SAP/N
wersja SAL/N
wersja SAL/M
Specification:
Marble concrete board:
Length
Width
Height
Mass
410 mm
270 mm
115 mm
29 kg
Table:
Length
Width
Height
Mass
770 mm
600 mm
800 mm
25 kg
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
PROFESSIONAL WEIGHING TABLE
Professional Weighing Table is intended for the use with
microbalances and analytical balances. It is incorporates an
independent anti-vibration table with a stone table top. This
solution eliminates possible vibrations and significantly
shortens balance stabilization time.
Two lockable cabinets and pull-out keyboard tray facilitate
installing PC computer with a keyboard, mouse, and UPS
power supply. The raised monitor platform at the rear part of
the table is designed for the installation of LCD monitor . The
table features high functionality and ergonomics.
1070
820
800
Unit contents
- weighing table
- anti-vibration table
1100
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
FOOT PRINT AND TARE BUTTONS
Foot button, by pressing it, sends to scale commands TARE
or PRINT (print weighing result).
It allows for performance of complex procedures for
weighing, filling and dosing with two hands involved in this
procedure, and simultaneous tarring, printing and sending
the result to computer. Proper cooperation of the system:
scale – computer – PRINT button – TARE button; is provided
by signal distributor also included in the set of buttons.
70
104
Set of TARE or PRINT buttons is applicable for laboratory
weighing instrument by RADWAG equipped with graphic
display and RADWAG industrial scales applying indicators or
terminals series: TMC and HX.
122
110
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
SET FOR DETERMINATION OF WATER VAPOUR PERMEABILITY
Permeability of water vapour is a feature which directly
determins quality and application of a specific material, for
instance cloth, shoes. Improper material if applied, may
result in unhealthy or uncomfortable use.
In order to determine content of water vapour, moisture
analyzer is equipped with special vessel.*
Developed method of permeability of water vapour is based
on locating adequate amount of water in special vessel made
of aluminum alloy, on which the cut-out sample is clamped.
Vessel with properly calculated amount of water and a piece
of cloth cut with blanking tool is placed in drying chamber of a
moisture analyzer.**
Before that, the vessel is kept for 24 hours in stable climate
conditions. Than, as the vessel is in drying chamber of
moisture analyzer, it is dried in temperature 140 °C. Big
advantage of this procedure is very short sampling time
(overall approximately 50 minutes, whereas standard
method takes approximately 72 hours!).
Results of those analysis are given in mg of
H2O/1000mm2/24h or by percentage ratio of amount of
water vapour transmitted through material to amount of
water vapour transmitted without examined material.
A
B
C
D
A – vessel lid
B – sample
C – water
D – moisture analyzer weighing pan
* registered in PO No W 116646
** registered in PO No P 381787
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
DENSITY KIT
Determining the density of solids and liquids is an
inseparable part of work of the laboratories. Traditional
method of density determination requires from the operator
many measurements and a lot of complex calculation. In
result the operator ends with a density determination result
which can be saddled with calculation and systematic
errors. Additionally time that needs to be devoted to density
calculation is long. In case of determining the density of
solids and liquids with application of Radwag density
determination kit, the whole procedure is very much
simplified and speeded up. Time till the operator receives the
density measurement is very short, as all the calculation is
performed by the software of the weighing instrument, and
operator’s activities is limited to:
- operation of the keyboard of weighing instrument,
- placing the samples on the weighing pans of the kit,
- hanging the plunger.
Density determination kit is additional equipment offered to
Radwag laboratory balances. The software for determination
of density has following basic features:
-simplicity of usage (all activities are described on the display
of the balance),
-reliability (all calculation is automatically performed by the
balance’s software),
-fast data processing (result is obtained after determination
of sample mass in water or plunger mass in liquid),
-accurate data processing (before every measurement of
mass, display indication is automatically zeroed, this proves
the density determination result to be reliable and real).
Specification:
1-beaker base
2-pans suspension
3-plunger
4-beaker
5-thermometer holder
6-thermometr
7-plunger string
8-hook
9-upper pan of the set for density determination of solids
10-pan string
11-lower pan of the set for density determination of solids
12-additional weight
13-additional stand for set of pans or plunger
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
STAND FOR UNDER HOOK WEIGHING
Stand for weighing loads in under hook weighing method.
Loads are placed on special pan hanged on a hook mounted
to the bottom of the scale.
210
335
Application of a stand is recommended when measuring
mass of magnetic materials, materials with non-standard
dimensions or shapes. Measurement with application of the
stand is in most cases more precise, as it eliminates the
possibility of not ideal placing of the load on a weighing pan
and in result it decreases the possible measuring error.
Additionally, stand is applicable for determination of density
of solids and liquids.
330
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ANTIDRAUGHT SHIELD FOR MICROBALANCES
Anti-draught chamber is intended for microbalances.
It is an optional equipment of microbalances working in
unfavourable conditions (air-draughts and breezes)
254
It is mounted on a table,a microbalance is placed inside a
chamber. It features sliding side windows allowing for free
access into the weighing chamber of a microbalance.
256
486
25 0
536,5
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ANTIDRAUGHT SHIELD
The antidraught shield can be used for protecting the
weighed objects against external environment, especially
wind or breeze in production halls. It is additional equipment
to the balances series WPS, WPX with pan size
128×128mm.
Protecting the weighed objects against wind has very good
influence of measuring results. It eliminates the possibility of
vibration of an object caused by external conditions while
taking its measurements.
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ANTI DUST SHIELD FOR PRINTERS
Anti dust shield is applicable as protection to printers series
Epson and Citizen models CLP 521 and CLP 621.
It is used in cases, where a printer is operating in heavily
dusted areas. Such airtight shield protects a printer against
defects, and allows for operation in not adapted places.
300
430
~ 91
~350
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
CEREAL DENSITY KIT
This kit is designed for determination of density of cereals.
Measurement of cereal density in loose state is performed
with application of precise balance series WPX 4500/G and
density kit for cereals. Density determination result is
calculated automatically by balance software (in accordance
to tables containing cereal density).
It is possible to determine the density of following cereal:
wheat, oats, barley, rye.
Manufactured of brass, the density kit is additional
equipment to a balance. Its volume is 1 liter.
The cereal density kit allows for determination of density
according to norm: PN-73/R-74007.
CEREAL DENSITY KIT
1-base for measuring container
2-measuring container of 1 l volume
3-knife
4-ring
5-filling device
6-charging vessel
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
CONTROL THERMOMETER PT-101
•pocket thermometer designed for temperature
determination by a sensor without cable or a sensor on cable.
•depending on the requirements it is possible to choose
between sensor with smaller or bigger accuracy.
•exchange of the sensor does not require calibration –
electronic storing of factory calibration on the head.
•sensors are built into a stainless steel tubes with diameter
3mm.
•tip of the sensor can be finished as sharp edge or flat.
•sharp sensors can be equipped with a transverse handle.
•cables: silicon or with strengthening steel braid.
•fully waterproof casing.
•automatic switch off as prevention against battery
discharge.
•”HOLD” function (holding the result on the display).
•power supply by batteries 3 x 1.5V (LR44).
• CE marking
Control of reliability of temperature indications
Based on checking whether the temperature inside the
drying chamber is the same as the temperature displayed on
the moisture analyzer display. Control is performed with
attested thermometer PT 101. It is an additional equipment
offered to each moisture analyzer. It should be noted here,
and remembered, that both thermometers control the
temperature of air with small distance from controlled
sample.
Factor correcting the temperature of drying
Materials with dark colour have special drying effect causing
absorption of heat. In such case it is possible that the sample
will be overheated, and so if the drying temperature has been
set for 120°C the dark coloured sample absorbs heat and
reaches temperature about 135°C. In such case, the
temperature correcting factor should be determined.
Determination of this parameter should be done with control
thermometer with a probe (additional equipment to a
moisture analyzer).
Specification:
Measuring range
Resolution
Accuracy depending
on the class
of sensor accuracy
Mass
Dimensions
Power supply
-70 ÷ 130 °C * -70 ÷ 400 °C **
in range -70 ÷ 199.9 °C — 0.1 °C, above 199.9 °C — 1.0 °C
range
-70 ÷ 0 °C
0 ÷ 100 °C
100 ÷ 200 °C
200 ÷ 400 °C
Pt-1000B
±0.9 °C
±1.0 °C
±1.5 °C
±3.0 °C
Pt-1000S
±0.9 °C
±0.3 °C
±1.5 °C
±3.0 °C
75 g
l = 143 mm, o = 26 mm
batteries LR44 x 3
* sensor without cable ** sensor with cable
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
RACK FOR MEASURING INDICATOR
Rack for measuring indicator allows for easy operation and
easy reading of the weighing results from scale. Easy
arrangement (within the range of cable length) allows for
operation of scale with no limitation to platform access, and in
result simplifies placing the load on the weighing platform.
Handle of the measuring indicator in moveable in vertical
direction for easy reading and operation of the indicator.
Construction of the rack also simplifies the installation and
de-installation of the indicator.
Triple legged rack provides stable base independently on the
surface on which the rack is placed. The distance between
the legs secures the rack against overturning even while
operating the indicator.
92
~785
30o
~428
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
HANDLE FOR INDICATOR IN PLASTIC CASING
Handle is used for mounting the indicator series PUE C31 on
wall.
Simple mounting solution allows for installation of the handle
on any horizontal and vertical surface. (preferably vertical
surface with little deviation from the exact verticality).
The base of the handle enables changing the angle of
indicator installation in wide range, according to user
requirements. It is manufactured in mild steel technology,
adjusting the position by big handwheel made from plastic.
40
15°
o7
2×
38
60
°
90
107
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ADDITIONAL DISPLAY
Additional display WD-4/1 in cooperation with measuring
indicator series PUE C/31. Data displayed on the additional
display are identical to those presented on the indicator of
weighing instrument. WD-4/1 :
ABS plastic casing, cable with input DB9.
Basic features:
• automatic detection of speed of transmission
• automatic switch off
• LCD backlight
• power supply from measuring indicator (scale)
Additional display WD-3/01 in cooperation with scales PS,
PS/X, XA/X, AS/X, AS, APP and APP/X.
Basic features:
• automatic switch off
• LCD backlight
• power supply from measuring indicator (scale)
ok. 98
150
118
33
80
Specification:
Power supply
Digit size
Connection cable length
Dimensions
6V DC from measuring indicator (scale)
19 mm
1,5 m
150 × 80 × 33 *
* dimensions do not include cable chokes and holders for mounting
58
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ADDITIONAL DISPLAY WD -4/3
WD-4/3 : stainless steel casing, cable with 4pin input (IP67)
for cooperation with measuring indicator series PUE C/31H,
PUE C/31H/Z
Basic features:
• automatic detection of speed of transmission
• automatic switch off
• LCD backlight
• power supply from measuring indicator (scale)
Specification:
Power supply
Digit size
Connection cable length
Dimensions
6V DC from measuring indicator
19 mm
1,5 m
170 × 104 × 47 *
* dimensions do not include cable chokes and holders for mounting
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
LARGE ADDITIONAL DISPLAY WWG-2
Additional large size LCDs on stainless housings. 6 digits
4.5” (11.2cm). They are equipped with holders that can be
used as a basis for standing it on a table or hanging on a wall.
They are intended for cooperation with weighing indicators
and terminals: PUE C/31H, PUE C41H, TMC, PUE 5.
LCD LED backlit, stainless steel housing. Communication
with indicators and scales via RS232, RS485 or optionally
Ethernet. Depending on the version power supply 230VAC or
7-24VAC.
Different makes:
WWG-2/1: RS485, supply 7-27VAC. Main intended use with
TMC terminals for vehicle scales
WWG-2/2: RS485, supply 230VAC. Intended use with PUE
C41H for operation in the distance of more than 10 m from
the terminal
WWG-2/3: RS232, supply 230VAC. Intended use with PUE
C/31H. Maximum cable length of RS232 is 10m
WWG-2/4: RS232, supply 230VAC. Intended use with PUE
C41H or PUE 5. Maximum cable length of RS232 is 10m
WWG-2/5: Ethernet, supply 230VAC. Intended use with
scales equipped with the Ethernet interface
48
111,7
195
635
17
Specification:
Casing
Digit height
Intended for
Interface
Connection
Transmission cable lenght
Power supply
Operation temperature
Interface
Dimension without handler
Net weight
WWG-2-1
WWG-2-2
TMC
RS 485
gland
up to 150 m
7-24 VAC
PUE C/41H
RS 485
connector
5 m (option max 150m)
230 VAC
WWG-2-3
stainless steel
4,5"
PUE C/31H
RS 232
connector
3 m (option max 10m)
230 VAC
-10 ÷ 40°C
IP 66/67
635×195×48 mm
5,5 kg
WWG-2-4
WWG-2-5
PUE C41H, PUE 5
RS 232
connector
3 m (option max 10m)
230 VAC
PUE C41H, PUE 5, TMC
Ethernet
connector, gland
3m
230 VAC
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ULTRASONIC AIR IONIZER DJ-01
Antistatic ionizer is a device that removes surpluses of ions,
mostly positive ones, but also negative ones from weighed
product, balance elements and its surrounding. Deionization
is about air molecules electric charge neutralizing, which
helps restore quasi-balance of positive and negative ions.
Unbalance of positive and negative ions In air is mostly the
reason of undesirable electric influences ( attraction or
repulsion) on elements that are close to each other. The
phenomenon is intensified if materials that do not conduct
electricity are used (plastics, glass).
Because balances contain such materials, the problem
influences their operating meaningfully. The influence occurs
as multiplied repeatability error and often as multiplied
indication error.
Most often unfavourable electrostatic interactions
phenomenon takes place In surroundings where there is low
relative humidity, that is below 40%. Antistatic ionizer DJ-01
is a device that meets all requirements of valid directives.
It draws very low power (below 1W), removes surpluses of
both positive and negative ions from air, its shape and
structure enables easy adapting it to optional analytical
balance or microbalance.
For tens of years scientific researches have been intensively
carried out on air ionic composition. On their basis it has been
stated that the factor, among temperature and air humidity,
should be treated as significant climate parameter.
177
25
Main source of energy that ionizes atoms and gas molecules
that are present In air, is radiation emitted by radioactive
elements which can be found in air and lithosphere. In man
surrounding, ions can be created mostly as a result of
electrical and heating devices operating.
It is generally accepted that both signs light ions optimal
content should be equal to 1000 pieces in 1 cm3 of air. Such
conditions can be found on sea coasts, in forests, where
positive and negative ions amounts are similar.
328
In fact there is slight predominance of positive ions over
negative ones In our environment.
110
209
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
POWER ADAPTER WITH BUFFER ZR-02
This power adapter allows for sustaining power when power
supply is decaying. It includes built in accumulator and
microprocessor controlling. Power adapter can operate in
buffer mode and in cycle mode. Buffer mode: - simultaneous
charging the battery and power supply to the weighing
instrument – cycle mode:
- operation with no connection to mains 230V, power supply
to weighing instrument from built in accumulator.
Estimated time of operation of weighing instruments
powered from accumulator (in surrounding temperature
20°C):
76
100
Power adapter status is signalized by two LED diodes
•green LED diode pulsating Cycle operation mode,
accumulator charged, and sustained with low power supply
•green LED diode flashing constantly Accumulator charging
or its sustaining in buffer operation mode
•red LED diode pulsating Power consumption from battery
with 230 V AC mains not connected.
Battery with sufficient power reserve.
•red LED diode flashing constantly and periodically sound is
heard Power consumption from accumulator with 230V AC
mains not connected, batery discharged, charging required
(connect to mains 230 V AC).
•red and green LED diodes flashing constantly and
periodically sound is heard (during charging).
Fuse of the accumulator defected •no diode is flashing Power
adapter not connected to 230 V AC mains and no power
consumption from accumulator.
181
Specification:
Power supply
Anti fire prevention class
Maximal power consumption
Power on output
Constant resisting power in buffer mode
Constant resisting power in cycle mode
Operation temperatures
Accumulator
Accumulator protection
Fuse
Dimensions
Total weight
230V AC
II
18VA
10 ÷ 15V
450mA
340mA
0 ÷ 40°C
12V 3,4Ah
polimeric fuse
T200mA/250V
181 × 76 × 100
2,2kg
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
SUITCASE FOR SCALE
Special design providing protection for weighing instrument
while transporting to location. Durable for shocks (aluminum
construction with internal filling from polyurethane foam).
Manufactured in two versions:
- W1 for balances: WPX, PS xx/C2, PS xx/C1, WLL xx/A2,
WLC xx/A1, WLC xx/A2 - with pan size: 195×195 mm.
135
- W2 for balances: WLC xx/C1/K, WTC xx/C1/K,
WLL xx/C1/K - with pan size 290×360 mm.
400÷600
300÷400
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
ROLLER CONVEYORS
Base with rollers manufactured in stainless steel Versions
of stainless steel rollers suitable for scales:
H1 – for stainless steel scales with platform size 250×300
H2 – for stainless steel scales with platform size 410×410
H3 - for stainless steel scales with platform size 500×500
H4 - for stainless steel scales with platform size 600×600
A
A
o 38
o 38
Offered in two options: with / without limiters.
~(B+8)
~(B-42)
~(B+15)
B
without limiters
with limiters
~ 80
70
86
~(B-80)
Specification:
Material for
Pan size
Dimension A
Dimension B
Version H1
stainless steel
250×300
300
250
Version H2
stainless steel
410×410
410
410
Version H3
stainless steel
500×500
500
500
Version H4
stainless steel
600×600
600
600
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
RAMPS FOR LOW PROFILED SCALES
Ramps are used for easy placing the trolley with load on the
low profiled scales. This solution allows for installation of the
scale in production line as a measuring or control stand. Easy
loading and unloading the platform assures smooth control
and operation with very much shortened time devoted to load
movement.
Because of very low height of the ramps, they should be used
only with low profiled scales. Angle of ramp inclination is also
adjusted to low platform height (the higher platform, the
longer the ramps). The reason is that loads with high mass
can not be driven to the weighing platform through steep
inclination.
C
B
A
oE
~10
F×G
N
Specification:
Platform capacity
150 kg
150 kg
150 kg
300 kg
300 kg
300 kg
600 kg
600 kg
600 kg
600 kg
1000 kg
1000 kg
1000 kg
1000 kg
platform A×B
800×800 mm
1000×1000 mm
1200×1200 mm
800×800 mm
1000×1000 mm
1200×1200 mm
800×800 mm
1000×1000 mm
1200×1200 mm
1500×1500 mm
800×800 mm
1000×1000 mm
1200×1200 mm
1500×1500 mm
C
57 mm
57 mm
57 mm
59 mm
59 mm
59 mm
74 mm
74 mm
79 mm
79 mm
74 mm
74 mm
79 mm
79 mm
E
40 mm
40 mm
40 mm
40 mm
40 mm
40 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
50 mm
F×G
736×736 mm
915×915 mm
1136×1136 mm
736×736 mm
936×936 mm
1136×1136 mm
715×715 mm
915×915 mm
1115×1115 mm
1415×1415 mm
715×715 mm
915×915 mm
1115×1115 mm
1415×1415 mm
N
~540 mm
~540 mm
~540 mm
~560 mm
~560 mm
~560 mm
~695 mm
~695 mm
~745 mm
~745 mm
~695 mm
~695 mm
~745 mm
~745 mm
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
BAR CODE SCANNER LS2208
The LS 2208 scanner combines excellent scanning
performance and advanced ergonomics to provide the best
value in a lightweight laser scanner. Whether used as a
hand-held scanner or in hands-free mode in a stand, the
scanner ensures comfort and ease of use for extended
periods of time.
Specification:
Power supply
Light source
Scanning system
Speed of reading
Reading distance
Ray shape
Working temperature
Read bar codes
Interface
Scanner dimensions
Scanner weight
LS 2208
5V DC from terminal (scale)
VLD 650 nm
laser diodes
100 scans/sec
0÷58,4 cm
single line
0÷500
Code 128, UCC/EAN-128, UPC-A, EAN/JAN-13, Codabar,
Code 39/Code 32, Standard/Industrial/Interleaved/Matrix 2 of 5,
IATA, Code 11, MSI/Plessey, Telepen, German Postal Code
RS232
84×63×152
146g without cable
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
BAR CODE SCANNER POWERSCAN D8330
Power scanner D8330 is a handheld device designed for
exploitation in hard industrial conditions.
It is compatible with:
- PUE C41 H
- PUE 5
- TMC
Versions:
D8330 - Standard
D8330 AR – Increased Reading Range
D8330 features new technology 3GL ( three green lights)
which results in excellent reading parameters. Patented
“Green Spot” directly in the code and double red diodes on
the surface and underneath the cover facilitate higher clarity
of information under various user accounts. High reading
parameters are enhanced by patented PuzzleSolver –
technology of fast and precise standard reading. The
mechanics of D8330 has been developed and tested against
extremely hard environmental conditions, maintaining stable
reading throughput and reliability. The ergonomic casing is
light and well-balanced to ensure optimal comfort of
operation. Built-in metal hook designed for the use in a
suspended position facilitates higher work throughput of a
workstation.
Multiple interfaces: RS 232, keyboard, Wand Emulation and
USB make it a versatile device.
Specification:
Recognized bar codes 1D
Stacked codes
Power consumption
Stand-by power consumption
Supply voltage
Drop resistance
ESD resistance
Maximal humidity ( without condensation)
Operating temperature
Storage temperature
Interface
Dimensions
Weight
Minimal print contrast ratio
Maximal reading speed
Resolution
PowerScan D8330
automatic recognition of standard codes including GS1 Databar Linear Codes
Code 16K, Code 49
420mA for 4V, 310mA for 5V, 62mA for 30V
4mA
4-30V DC
withstands 50 drops from 2m
20kV
90%
-20°C to 50°C
-20°C to 70°C
RS232, USB, Keyboard Wedge, Wand,
207×114×69mm
Weight: 295g
15%
35 ± 5 scans/sec
0,076mm for version AR 0,19m
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
BAR CODE SCANNER POWERSCAN M8300
Power scanner M8300, M8300D is a handheld device
designed for exploitation in hard industrial conditions. PM
3800 – wireless scanner is the most advanced product.
Narrow-band wireless communication enables higher
throughput and flexibility at a workstation. Furthermore, it
creates new possibilities of scaling solutions – from a single
workstation to network systems.
It is compatible with:
- PUE C41 H
- PUE 5
- TMC
The scanners are available in the following versions:
M8300 standard
M300 D with a display
M300 AR increased reading range
M300 D/AR with a display and increased reading range
Specification:
PowerScan M8300
Wireless communication
DATALOGIC Star Cordless System
RF signal strength
433,92MHz - <10mW, 910MHz - < 1mW
Maximum number of scanners in the range
2000
Maximum number of scanners for one base station
21
Frequency
433,92Mhz 910Mhz
Range (open space)
up to 50m for 433,92 EUR, to 30m for 910Mhz
Recognized bar codes 1D
automatic recognition of standard codes including GS1 Databar Linear Codes
Stacked codes
Code 16K, Code 49
Accumulator
Li-ION 2150 mAh
Charging time
external charger – 4 hours, base charger – 10 hours
Number of scans on a single charge
60 000
Information diodes
discharging-red, charging finished – green, power supply / data connection – yellow
Power consumption
1A dla 10V, 330mA for 30V, POT 500mA
Supply voltage
10-30V DC, POT 5V DC ± 10%
Drop resistance
withstands 50 drops from 2m
ESD resistance
20kV
Maximal humidity ( without condensation)
90%
Environmental protection
IP65 for M8300, IP64 for M8300D
Operating temperature
-20°C to 50°C
Storage temperature
-20°C to 70°C
Interfaces
RS232, USB, Keyboard Wedge, Wand, RS485 (only with base station BC8060)
Dimensions
base – 240×108×95mm, M8300 – 207×114×69mm, M8300D – 210×114×69mm
Display
only for M8300D graphic display 4 lines 16 columns, 32x96 pixels
Keyboard
only for M8300D 3 buttons
Mass
base – 380g, scanner – 395g
Light source
630 – 680mm VLD
Minimal print contrast ratio
15%
Maximal reading speed
35 ± 5 scans/sec
Reading index
Biper, Datalogic Greek Lighst (3GL™)
Resolution
0,076mm for version AR 0,19mm
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
TRANSPONDER CARD READER CK-01
133
2×
o6
,5
Applicable for fast identification and logging of operators of
weighing systems or identification of vehicles on
weighbridges.
The reader is designed for cooperation with weighing
instruments equipped with TMC terminals.
30
98
115
70
Specification:
Type of operated cards
Power supply
Working temperature
Interface
Dimensions
UNIQUE
5V DC from weighing terminal, 9-24V AC (optional external power supply)
-10°C ÷ 40°C
RS232, (optional RS485)
98 × 133 × 30 without mounting handle
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
CONVERTER RS 232/RS 485 KR-01
A device designed for mutual adjusting the signals of
standards RS 232 and RS 485.
It is equipped with automatic detection of the direction in
which the data is transferred. It is has galvanized separation
of the interfaces RS 232 and RS 485.
Applicable with weighing systems.
RS 232
Sceles system
RS 485
converter
RS232 / RS485
KR-01
power
adapter
35
230V AC
129
68
Specification:
Power supply
AC 230V/120V 50Hz 25mA
Speed of transmission
9600 do 57600 byte/sec
Choice of transmission direction
automatic
Galvanized separation between the interfaces
do 1,5 kV DC
Cable RS232
1,5m with plug DB9
Cable RS485
1,5m
Working temperature
-10°C ÷ 40°C
Casing
plastic
Dimensions
68 × 129 × 35
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
CONVERTER RS 232/ETHERNET KR-04
35
Converter KR-04 RS232 Ethernet is designed for scales
equipped with interface RS232.
It is used for adjusting the signal to both standards RS 232
and Ethernet.
Converter is accessible in three options:
KR-04-1 : plastic casing, RS 232 cablewith plug DB9F,
Ethernet socket RJ45, powered from mains external power
adapter 230V/11V AC
KR-04-2 : stainless stee lcasing, RS 232 cable with
waterproof, plug, Ethernet cable let out through a choke,
power supply 230V AC
KR-04-3 : stainless stee lcasing, RS232 cable with
waterproof plug, waterproof Ethernet socket, power supply
230V AC
129
68
Specification:
Casing
Ethernet output
Applicable with scales*
Communication with indicator, scale
RS 232 speed
Ethernet standard
Power supply
Working temperature
KR-04-1
plastic
socket RJ45
scales with DB9 output
ext. power adapter 230V/120V/11V
KR-04-2
stainless steel
cable through choke
PUE C31/H, PUE C31/H/Z
RS232
from 50 bps to 115.2 Kbps
10/100 Mbps, (1,5 KV magnetic isolation)
230V/120V AC 50Hz
0° - 40° C
KR-04-3
stainless steel
hermetic socket**
PUE C31/H, PUE C31/H/Z
230V/120V AC 50Hz
*) specify type of scale (measuring indicator) when placing an order
**) cable model P0198 required for Ethernet is not part of converter equipment
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
INPUT / OUTPUT MODULE PP-01
In /Out module PP-01 is designed for changing the transistor
outputs into relay outputs in order to increase their maximal
resistance.
In/Out module is equipped with three relay outputs, and it is
powered from independent power source 230V AC. It has
also power output +5VDC. Additionally, module allows for
powering three control buttons and connection of
signalization diodes for the relay activation.
The device is manufactured in two casings:
-PP-01-1 : plastic casing IP 55
-PP-01-2 : stainless steel casing IP 67
SCHEMA OF SINGLE RELAY OUTPUT
NC
72
54
NO
119
135
170
162
70
Specification:
PP-01-1
Power suply
Quantity of relay outputs
Maximal current on replay contacts
Maximal current if output +5V DC
Working temperature
Casing
Dimensions
IP rating
PP-01-2
230V/120V AC 20mA
3
3A/250V AC
200mA
-10°C ÷ 40°C
plastic
170 × 54 × 135 *
IP 55
stainless steel
162 × 72 × 119 *
IP 67
* dimensions do not include the cable chokes and handle for mountinga
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
EXTERNAL CURRENT LOOP POWERED
Module of power output 4–20mA manufactured by ZMP
Radwag
is designed for conversion of digital reading mass onto
analog value. It cooperates with Radwag weighing
instruments. Power output is a wattless, i.e. it requires supply
of external power supply to power loop with current 24VDC.
Module of power loop can reflect on its output mass
indications as below specified:
• absolute value (no consideration of sign)
• only positive values
• mass indication with consideration of sign
Module of power loop can be offered with following
measuring indicators (scales) PUEC/31
Diagram of power loop set 4-20mA
white
modul of current
output AP2
receiver
green
DC
24V
35
power adapter
68
Module power supply
Power supply of power loop
Power looses
Output resolution
Linearity error
Indication error 4mA (+25C)
Temperature error for 4mA
Indication error 20mA (+25C)
Temperature error for 20mA
Working temperature range
Cable RS232
Output cable
Dimensions
230V/120V AC/ 5V DC 500mA
24V DC
450 mW
16 Bit
+/- 0.01 %
+/- 0.1 %
+/-25 ppm/°C
+/- 0.2 %
+/-50 ppm/°C
-10°C ÷ 40°C
1,5m with plug
1,5m
65 × 28 × 128
129
Specification:
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com
CABLES
• P0166
Cable for connection of measuring indicator with KAFKA printer.
Designed for:
TMC–COM2
TMC weighbridge –COM3
Standard cable length 2m
Cables RS232 – EPSON, CITIZEN
• P0102
Cable for connection of measuring indicator with EPSON or
CITIZEN printer. Designed for:
HX weighing terminal
Standard cable length 1,7m
• P0151
Cable for connection of measuring indicator (weighing terminal) with EPSON or
CITIZEN printer.
Applicable with all measuring instruments by Radwag equipped with output
RS232 DB9/M (male). Standard cable length 1,7m.
• P0171
Cable for connection of measuring indicator with EPSON or
CITIZEN printer. Designed for:
TMC weighing terminal
Standard cable length 2m
• P0261
Cable for connection of measuring indicator with EPSON or
CITIZEN printer. Designed for:
PUE C/31H, PUE C/31H/Z
Standard cable length 2m
Cables RS232 – computer
• P0107
Cable for connection of measuring indicator (weighing terminal) with computer.
Designed for:
HX weighing terminal
Standard cable length 1,7m
• P0108
Cable for connection of measuring indicator (weighing terminal) with computer.
Applicable with all measuring instruments by Radwag equipped with output
RS232 DB9/M (male).
Standard cable length 1,7m
• P0165
Cable for connection of measuring indicator with computer. Designed for:
TMC weighing terminal
Standard cable length 2m
• P0259
Cable for connection of measuring indicator with computer. Designed for:
PUE C/31H,PUE C/31H/Z
Standard cable length 2m
Cables RS232 –KAFKA
• P0136
Cable for connection of measuring indicator (weighing terminal) with KAFKA
printer.
Applicable with all measuring instruments by Radwag equipped with output
RS232 DB9/M (male).
Standard cable length 1,7m
• P0140
Cable for connection of measuring indicator with KAFKA printer.
Designed for:
HX weighing terminal
Standard cable length 1,7m
• P0253
Cable for connection of measuring indicator with KAFKA printer.
Designed for:
PUE C/31H, PUE C/31H/Z
Standard cable length 2m
Cable for supplying power from car lighter
• K0042
Cable for connection of measuring terminal to car lighter.
Designed for:
PUE C/31H/Z ,
Standard cable length 1,7m
• K0047
Cable for connection of measuring terminal to car lighter.
Designed for:
PUE C/31 in plastic casing. Standard cable length 1,7m
Cable RS485
• P0139
Cable for connection of measuring indicator (weighing terminal) with RS 485
network.
Designed for:
HX weighing terminal
Standard cable length 3m
Cable for Ethernet
• P0198
Cable for connection of weighing terminal to LAN not crossed network.
Connections:
RJ45 from LAN side
M12 4pin D-code from weighing terminal side
Designed for:
TMC weighing terminal with Ethernet output
Standard cable length 7m
RADWAG USA L.L.C.
19599 NE 10th Ave., Bay G, s
North Miami Beach, FL, 33179 s
USA s
Tel: 1-305-651-3522 s
Fax: 1-305-651-3523 s
e-mail: office@radwagusa.com s
website: www.radwagusa.com