Enterasys | 24-Port | [PSS 21H-7C3 B4] The MESH Control Network Ethernet

I/A Series® HARDWARE
Product Specifications
PSS 21H-7C3 B4
The MESH Control Network Ethernet Equipment
Primary Root
Ethernet
Switches
Ethernet
Switches
Backup Root
The MESH control network utilizes Invensys qualified Ethernet equipment to allow you to configure your
system to meet your functional, performance, and plant requirements.
FEATURES
 System scalability by interconnecting Ethernet
 Rapid Spanning Tree Protocol (RSTP), manages
switches, each having 8-ports or more in various
increments
 Support for Fast Ethernet (100 Mbps) and Gigabit
(uplink only) Ethernet (1000 Mbps)
 Modular uplinks to high-speed backbones using
1 Gb 1000Base-T, 1000Base-SX,
1000Base-LX, 1000Base-LX/LH, 1000Base-BX,
1000Base-TX, and 1000Base-ZX standards
 Full duplex operation based on the IEEE 802.3
standards
redundant paths, prevents loops, and provides
high speed convergence time for a network
 System Management software for monitoring the
health of the control system and managing
equipment in the system
 Network management and configuration via local
port
PSS 21H-7C3 B4
Page 2
 Virtual Local Area Networks (VLANs), separating
INTRODUCTION
the MESH Network into multiple segments. A
total of 6 VLANs can be configured; VLANs
configured for non-I/A Series communication can
only be configured for TCP and UDP protocol
use.
 Ethernet switches and converters are European
Union (EU) Low Voltage and EMC directives
safety certificated (“CE” logo marked on product).
The MESH control network equipment described
herein has been tested and qualified by Invensys for
use with I/A Series® system products.
The qualified Ethernet switches offered are listed in
Table 1. The qualified Media Converter offered is
listed in Table 2.
Table 1. Qualified Ethernet Switches
Switch
Page
(A4-Series) 24-Port Copper managed switch (P0973JM) with two RJ-45 uplink ports and two
ports for Mini-GBIC modules
page 3
(A4-Series) 24-Port Fiber managed switch (P0973JN) with two RJ-45 uplink ports and two ports
for Mini-GBIC modules
page 8
(A4-Series) 8-Port Copper/ 8-Port Fiber managed switch (P0973JP) with two RJ-45 uplink ports
and two ports for Mini-GBIC modules
page 12
(I-Series) Industrial managed switch, hardware consists of eight or sixteen fiber, twenty-four
copper, or eight fiber with twelve copper ports (P0973GA/GB/HB/HC) with two SFP(a) ports for
Mini-GBIC modules
page 16
(C-Series) 26-Gigabit (SFP(a)) Port managed switch (P0973KJ (C5)) provides up to twenty-six 1Gb
copper/fiber uplinks (ISL) or alternatively, a combination of Gigabit and 100Mb ports with up to
twenty-four 100Mb end device fiber connections using the 100Base-FX Mini-GBIC (P0973JE).
page 21
(B-Series) 24-Gigabit (RJ-45) Port managed switch (P0973LK) provides up to twenty-four
10/100/1000Base-TX Gigabit ports. Four SFP(a) ports can be populated with 1000Base-X MiniGBIC uplink (ISL) connector modules.
page 24
(S-Series) SSA Chassis managed switch (P0973KK) with 48-port 1000Base-T 1 Gb SFP uplink
ports and 4-port 10G SFP uplink ports configurable as 1 Gb uplink ports or alternatively, a
combination of Gigabit and 100Mb ports with up to forty-eight 100Mb end device fiber
connections using the 100Base-FX Mini-GBIC (P0973JE)
page 33
(S-Series) S4 Chassis managed switch (P0973KD) with up to 192 1 Gb SFP uplink ports,
configured as fiber or copper uplinks or alternatively, a combination of Gigabit and 100Mb ports
with up to 190 100Mb end device fiber connections using the 100Base-FX Mini-GBIC (P0973JE)
page 36
(a) Small Form Factor Pluggable
PSS 21H-7C3 B4
Page 3
Table 2. Qualified Media Converters
Media Converter
Page Reference
Media Converter 100Base-FX to 100Base-TX (P0972XH)
page 42
Media Converter 100Base-FX to 100Base-TX (P0972XH_D)
page 43
( A 4 - S ER I E S) 2 4 - P O RT C O P P E R M AN A G E D S W I T C H ( P 0 9 7 3 J M )
FEATURES
INTRODUCTION
The 24-Port Copper managed switch features:
The 24-Port Copper managed switch (P0973JM)
provides twenty-four 100Base-TX ports with RJ-45
connectors, two fixed 10/100/1000 stacking / uplink
(ISL) ports and two 1000Base-X uplink (ISL) Gigabit
(SFP) ports.
 24-ports of 100Base-TX
 Two fixed RJ-45 10/100/1000 ports, configurable
for uplink
 Two 1000Base-X uplink Gigabit (SFP) ports
 Full duplex operation
 Supports VLAN configurations
 Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
The two 1000Base-X uplink (ISL) Gigabit (SFP) ports
can be populated with MGBIC uplink (ISL) connector
modules listed in Table 3.
The switch allows high-performance, full-featured
layer-2 Ethernet switching in small to medium-sized
network applications, as well as high-performance
direct end-station connectivity.
 Port mirroring technology and diagnostics that
allow local network traffic to be redirected to an
external probe for detailed analysis
 Compliance with industry standards, including
IEEE 802.3u Fast Ethernet, 802.1w Rapid
Spanning Tree Protocol (RSTP)
 Optional redundant power supply
 Shelf, desk, or 19-inch rack mounting.
OPTIONAL REDUNDANT POWER SUPPLY
See “REDUNDANT POWER SUPPLY (P0973BP)” on
page 29.
PSS 21H-7C3 B4
Page 4
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) at the left, right, and rear of the
switch. Do not connect the switch to the ac
power source until instructed to do so later in the
installation process.
 Ambient temperature at the air inlet for each
switch must be maintained between 0° and 50°C
(32° to 122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
UPLINK/SWITCH INTERFACES
Table 3 lists the 24-Port Copper switch and the
uplink interfaces that can be added to the switch.
The uplink connectors are added to specific uplink
interfaces.
PSS 21H-7C3 B4
Page 5
Table 3. 24-Port Copper Managed Switch (P0973JM) Interfaces
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
Uplink Connectors
(Add to Interfaces)
Description
24-Port Copper
P0973JM Two 1 Gb uplink RJmanaged switch
45 ports, 1000Base-T
with two RJ-45
for Cat5 copper
ports for uplink and
cables
two ports for MiniTwo 1 Gb uplink
GBIC modules
ports, 1000Base-X,
for Mini-GBIC
modules
Description
Invensys
Part No.
n/a
Uplink module
1000Base-SX with LC
connector
P0972WT - MMF Refer to Table 11 on
page 45 to determine
maximum range for
your specific
application.
Uplink module
1000Base-LX with LC
connector
P0972WU - 10 km
(6.2 mi) with SMF
Uplink module
1000Base-LX/LH with
LC connector
P0972YQ - MMF Refer to Table 11 on
page 45 to determine
maximum range for
your specific
application.
Uplink module
1000Base-ZX with LC
connector
P0973FT - 80 km (49.6
mi) with SMF
Uplink module
1000Base-T with RJ-45
connectors
P0972YL - 100 m
(330 ft)
P0973JD(a) - 10 km
Bi-directional
downlink/uplink Mini(6.2 mi) with SMF MiniGBIC Kit - includes both GBIC Kit
P0973JB and P0973JC
modules
PSS 21H-7C3 B4
Page 6
Table 3. 24-Port Copper Managed Switch (P0973JM) Interfaces (Continued)
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
Description
24-Port Copper
P0973JM Two 1 Gb uplink
managed switch
ports, 1000Base-X,
with two RJ-45
for Mini-GBIC
ports for uplink and
modules (Cont.)
two ports for MiniGBIC modules
(Cont.)
Uplink Connectors
(Add to Interfaces)
Description
Invensys
Part No.
P0973KP(b) - 40 km
Bi-directional
downlink/uplink Mini(25 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KM and P0973KN
modules
P0973KS(c) - 120 km
Bi-directional
downlink/uplink Mini(74.6 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KQ and P0973KR
modules
(a) Kit P0973JD is comprised of two Mini-GBICs (P0973JB and P0973JC). P0973JC transmits “downstream” (from the core of the
network to the edge) uses the 1490 nm wavelength, and the “edge” P0973JB transmits “upstream” uses the 1310 nm wavelength.
(b) Kit P0973KP (40 km (25 mi)) is comprised of two Mini-GBICs (P0973KM and P0973KN). P0973KN transmits “downstream” (from the
core of the network to the edge) uses the 1490 nm wavelength, and the “edge” P0973KM transmits “upstream” uses the 1310 nm
wavelength over Simplex Single Mode Fiber (S-SMF).
(c) Kit P0973KS (120Km) is comprised of two Mini-GBICs (P0973KQ and P0973KR). P0973KR transmits “downstream” (from the core
of the network to the edge) uses the 1590 nm wavelength, and the “edge” P0973KQ transmits “upstream” uses the 1490 nm
wavelength over Simplex Single Mode Fiber (S-SMF) at a minimum distance of 30 km (19 mi).
PSS 21H-7C3 B4
Page 7
F U N C T I O N A L S P E C I F I C AT I O N S
2 4- P O RT C OP PE R M A N AG E D SW I T C H ( P 097 3J M )
Power
INTERNAL
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
Supports connection for redundant power supply
MAXIMUM POWER CONSUMPTION
31 Watts
MAXIMUM HEAT DISSIPATION
105 BTUs/Hr
MAXIMUM CURRENT
0.5 A at 110 V ac, 0.47 A at 220 V ac
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to +50°C (32 to +122°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
2.61 kg (5.8 lb)
Dimensions - Nominal
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.1 cm (17.36 in)
DEPTH
36.85 cm (14.5 in)
Cable Connectors
SWITCH PORTS
RJ-45
UPLINK PORTS
RJ-45 copper and LC fiber
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Location
47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
(EMI) (Class A) EN 55022, EN 61000-3-2, EN 610003-3, EN 55024,
AS/NZS CISPR 22, VCCI V-3
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Product Safety
Class G1 (Mild) as defined in ISA Standard S71.04
UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN
60950,
IEC 60950, EN 60825, 21 CFR 1040.10
Contamination
PSS 21H-7C3 B4
Page 8
( A 4 - S E R I E S ) 2 4 - P O RT F I B E R M A N A G E D S W I T C H ( P 0 9 7 3 J N )
FEATURES
The 24-Port Fiber managed switch features:
 24-ports of 100Base-FX
 Two fixed RJ-45 10/100/1000 ports, configurable
for uplink
 Two 1000Base-X uplink Gigabit (SFP) ports
 MT-RJ connectors on switch ports
 Full duplex operation
 Supports VLAN configurations
 Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
 Port mirroring technology and diagnostics that
allow local network traffic to be redirected to an
external probe for detailed analysis
 Compliance with industry standards, including
IEEE 802.3u Fast Ethernet, 802.1w Rapid
Spanning Tree Protocol (RSTP)
 Optional redundant power supply.
INTRODUCTION
The 24-Port Fiber managed switch (P0973JN)
provides twenty-four 100Base-FX ports with MT-RJ
connectors, two fixed 10/100/1000 stacking / uplink
(ISL) ports and two 1000Base-X uplink (ISL) Gigabit
(SFP) ports.
The two 1000Base-X uplink (ISL) Gigabit (SFP) ports
can be populated with Mini-GBIC uplink (ISL)
connector modules listed in Table 4.
The switch allows high-performance, full-featured
layer-2 Ethernet switching in small to medium-sized
network applications, as well as high-performance
direct end-station connectivity.
OPTIONAL REDUNDANT POWER SUPPLY
See “REDUNDANT POWER SUPPLY (P0973BP)” on
page 29.
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) at the left, right, and rear of the
switch. Do not connect the switch to the ac
power source until instructed to do so later in the
installation process.
 Ambient temperature at the installation site must
be maintained between 0° and 50°C (32° to
122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
PSS 21H-7C3 B4
Page 9
UPLINK/SWITCH INTERFACES
Table 4 lists the 24-Port Fiber managed switch and
the uplink interfaces that can be added to the switch.
The uplink connectors are added to specific uplink
interfaces.
Table 4. 24-Port Fiber Managed Switch (P0973JN) Interfaces
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
24-Port Fiber
P0973JN
managed switch
with two RJ-45
ports for uplink and
two ports for MiniGBIC modules
Uplink Connectors
(Add to Interfaces)
Description
Description
Invensys
Part No.
Two 1 Gb uplink RJ- n/a
45 ports, 1000Base-T
for Cat5 copper
cables
Two 1 Gb uplink
ports, 1000Base-X,
for Mini-GBIC
modules
Uplink module
1000Base-SX with LC
connector
P0972WT - MMF Refer to Table 11 on
page 45 to determine
maximum range for
your specific
application.
Uplink module
1000Base-LX with LC
connector
P0972WU - 10 km
(6.2 mi) with SMF
Uplink module
1000Base-LX/LH with
LC connector
P0972YQ - MMF Refer to Table 11 on
page 45 to determine
maximum range for
your specific
application.
Uplink module
1000Base-ZX with LC
connector
P0973FT - 80 km (49.6
mi) with SMF
Uplink module
1000Base-T with RJ-45
connectors
P0972YL - 100 m
(330 ft)
PSS 21H-7C3 B4
Page 10
Table 4. 24-Port Fiber Managed Switch (P0973JN) Interfaces (Continued)
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
24-Port Fiber
P0973JN
managed switch
with two RJ-45
ports for uplink and
two ports for MiniGBIC modules
(Cont.)
Description
Two 1 Gb uplink
ports, 1000Base-X,
for Mini-GBIC
modules (Cont.)
Uplink Connectors
(Add to Interfaces)
Description
Invensys
Part No.
P0973JD(a) - 10 km
Bi-directional
downlink/uplink Mini(6.2 mi) with SMF MiniGBIC Kit - includes both GBIC Kit
P0973JB and P0973JC
modules
P0973KP(b) - 40 km
Bi-directional
downlink/uplink Mini(25 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KM and P0973KN
modules
P0973KS(c) - 120 km
Bi-directional
downlink/uplink Mini(74.6 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KQ and P0973KR
modules
(a) Kit P0973JD is comprised of two Mini-GBICs (P0973JB and P0973JC). P0973JC transmits “downstream” (from the core of the
network to the edge) uses the 1490 nm wavelength, and the “edge” P0973JB transmits “upstream” uses the 1310 nm wavelength.
(b) Kit P0973KP (40 km (25 mi)) is comprised of two Mini-GBICs (P0973KM and P0973KN). P0973KN transmits “downstream” (from the
core of the network to the edge) uses the 1490 nm wavelength, and the “edge” P0973KM transmits “upstream” uses the 1310 nm
wavelength over Simplex Single Mode Fiber (S-SMF).
(c) Kit P0973KS (120Km) is comprised of two Mini-GBICs (P0973KQ and P0973KR). P0973KR transmits “downstream” (from the core
of the network to the edge) uses the 1590 nm wavelength, and the “edge” P0973KQ transmits “upstream” uses the 1490 nm
wavelength over Simplex Single Mode Fiber (S-SMF) at a minimum distance of 30 km (19 mi).
PSS 21H-7C3 B4
Page 11
F U N C T I O N A L S P E C I F I C AT I O N S
2 4 - P O RT F I B E R M A N A GE D S W I T C H ( P 0 9 7 3 JN )
Power
INTERNAL
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
Supports connection for redundant power supply
MAXIMUM POWER CONSUMPTION
66 Watts
MAXIMUM HEAT DISSIPATION
224 BTUs/Hr
MAXIMUM CURRENT
0.5 A at 110 V ac, 0.47 A at 220 V ac
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to +50°C (32 to +122°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
2.7 kg (5.95 lb)
Dimensions
Cable Connectors
SWITCH PORTS
MT-RJ fiber
UPLINK PORTS
RJ-45 copper and LC fiber
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.1 cm (17.36 in)
DEPTH
36.85 cm (14.5 in)
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
I47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
Location
(EMI) (Class A) EN 55022, EN 61000-3-2, EN 610003-3, EN 55024, AS/NZS CISPR 22, VCCI V-3
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Product Safety
Contamination
UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN
60950,
IEC 60950, EN 60825, 21 CFR 1040.10
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 12
( A 4 - S ER I E S ) 8 - P ORT C O P P E R / 8 - P O RT F I B E R M AN A G E D S W I T C H ( P 0 9 7 3 J P )
FEATURES
INTRODUCTION
The 8-Port Copper/8-Port Fiber managed switch
features:
The 8-Port Copper/8-Port Fiber managed switch
(P0973JP) provides eight 100Base-TX ports with RJ45 connectors, eight 100Base-FX ports with MT-RJ
connectors, two fixed 10/100/1000 stacking / uplink
(ISL) ports and two 1000Base-X uplink (ISL) Gigabit
(SFP) ports.
 8-ports of 100Base-FX
 8-ports of 100Base-TX
 Two fixed RJ-45 10/100/1000 ports, configurable
for uplink
 Two 1000Base-X uplink Gigabit (SFP) ports
 RJ-45 Category 5 connectors on switch copper
ports
 MT-RJ connectors on switch fiber ports
 Full duplex operations
 Supports VLAN configurations
 Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
 Port mirroring technology and diagnostics that
allow local network traffic to be redirected to an
external probe for detailed analysis
 Compliance with industry standards, including
IEEE 802.3u Fast Ethernet, 802.1w Rapid
Spanning Tree Protocol (RSTP)
 Optional redundant power supply
 Shelf, desk, or 19-inch rack mounting.
The two 1000Base-X uplink (ISL) Gigabit (SFP) ports
can be populated with Mini-GBIC uplink (ISL)
connector modules listed in Table 5.
The switch allows high-performance, full-featured
layer-2 Ethernet switching in small to medium-sized
network applications, as well as high-performance
direct end-station connectivity.
OPTIONAL REDUNDANT POWER SUPPLY
See “REDUNDANT POWER SUPPLY (P0973BP)” on
page 29.
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) at the left, right, and rear of the
switch. Do not connect the switch to the ac
power source until instructed to do so later in the
installation process.
PSS 21H-7C3 B4
Page 13
 Ambient temperature at the installation site must
be maintained between 0° and 50°C (32° to
122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
UPLINK/SWITCH INTERFACES
Table 5 lists the 8-Port Copper/8-Port Fiber switch
and the uplink interfaces that can be added to the
switch. The uplink connectors are added to specific
uplink interfaces.
Table 5. 8-Port Copper / 8-Port Fiber Managed Switch (P0973JP) Interfaces
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
8-Port Copper/ 8- P0973JP
Port Fiber managed
switch with two
RJ-45 ports for
uplink and two
ports for Mini-GBIC
modules
Uplink Connectors
(Add to Interfaces)
Description
Description
Invensys
Part No.
Two 1 Gb uplink RJ- n/a
45 ports, 1000Base-T
for Cat5 copper
cables
Two 1 Gb uplink
ports, 1000Base-X,
for Mini-GBIC
modules
Uplink module
1000Base-SX with LC
connector
P0972WT - MMF - Refer
to Table 11 on page 45
to determine maximum
range for your specific
application.
Uplink module
1000Base-LX with LC
connector
P0972WU - 10 km
(6.2 mi) with SMF
Uplink module
1000Base-LX/LH with
LC connector
P0972YQ - MMF - Refer
to Table 11 on page 45
to determine maximum
range for your specific
application.
Uplink module
1000Base-ZX with LC
connector
P0973FT - 80 km (49.6
mi) with SMF
Uplink module
1000Base-T with RJ-45
connectors
P0972YL - 100 m
(330 ft)
PSS 21H-7C3 B4
Page 14
Table 5. 8-Port Copper / 8-Port Fiber Managed Switch (P0973JP) Interfaces (Continued)
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
8-Port Copper/ 8- P0973JP
Port Fiber managed
switch with two
RJ-45 ports for
uplink and two
ports for Mini-GBIC
modules (Cont.)
Description
Two 1 Gb uplink
ports, 1000Base-X,
for Mini-GBIC
modules (Cont.)
Uplink Connectors
(Add to Interfaces)
Description
Invensys
Part No.
P0973JD(a) - 10 km
Bi-directional
downlink/uplink Mini(6.2 mi) with SMF MiniGBIC Kit - includes both GBIC Kit
P0973JB and P0973JC
modules
P0973KP(b) - 40 km
Bi-directional
downlink/uplink Mini(25 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KM and P0973KN
modules
P0973KS(c) - 120 km
Bi-directional
downlink/uplink Mini(74.6 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KQ and P0973KR
modules
(a) Kit P0973JD is comprised of two Mini-GBICs (P0973JB and P0973JC). P0973JC transmits “downstream” (from the core of the
network to the edge) uses the 1490 nm wavelength, and the “edge” P0973JB transmits “upstream” uses the 1310 nm wavelength.
(b) Kit P0973KP (40 km (25 mi)) is comprised of two Mini-GBICs (P0973KM and P0973KN). P0973KN transmits “downstream” (from the
core of the network to the edge) uses the 1490 nm wavelength, and the “edge” P0973KM transmits “upstream” uses the 1310 nm
wavelength over Simplex Single Mode Fiber (S-SMF).
(c) Kit P0973KS (120Km) is comprised of two Mini-GBICs (P0973KQ and P0973KR). P0973KR transmits “downstream” (from the core of
the network to the edge) uses the 1590 nm wavelength, and the “edge” P0973KQ transmits “upstream” uses the 1490 nm wavelength
over Simplex Single Mode Fiber (S-SMF) at a minimum distance of 30 km (19 mi).
PSS 21H-7C3 B4
Page 15
F U N C T I O N A L S P E C I F I C AT I O N S
8 - P O RT C O P P E R / 8 - P O RT F I B E R M AN A G E D S W I T C H ( P 0 9 7 3 J P )
Power
INTERNAL
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
Supports connection for redundant power supply
MAXIMUM POWER CONSUMPTION
47 Watts
MAXIMUM HEAT DISSIPATION
160 BTUs/Hr
MAXIMUM CURRENT
0.5 A at 110 V ac, 0.47 A at 220 V ac
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to +50°C (32 to +122°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
2.7 kg (5.95 lb)
Dimensions
Cable Connectors
SWITCH PORTS
RJ-45 copper and MT-RJ fiber
UPLINK PORTS
RJ-45 copper and LC fiber
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.1 cm (17.36 in)
DEPTH
36.85 cm (14.5 in)
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Location
47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
(EMI) (Class A) EN 55022, EN 61000-3-2, EN 610003-3, EN 55024, AS/NZS CISPR 22, VCCI V-3
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Product Safety
Contamination
UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN
60950,
IEC 60950, EN 60825, 21 CFR 1040.10
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 16
( I - S E R I E S ) M A N A G E D I N D U S T R I A L LY H A R D E N E D S W I T C H ( P 0 9 7 3 G A / G B / H B / H C )
FEATURES
INTRODUCTION
The hardware configurable Industrial Fiber managed
switch features:
The Industrially Hardened managed switches provide
the following ports:
 8-ports or 16-ports of 100Base-FX, or 24-ports
 P0973GA - twenty-four 100Base-TX ports with










of 100Base-TX, or 8-ports 100Base-FX and
12-ports of 100Base-TX (depending on hardware
configuration)
Two 1000Base-X uplink Gigabit (SFP) ports
Fully Hardened Ethernet Switch
Redundant DC power connections
Convection cooled
Full duplex operation
Supports VLAN configuration
Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
Port mirroring technology and diagnostics that
allows local network traffic to be redirected to an
external probe for detailed analysis
Compliance with industry standards, including
IEEE 802.3u Fast Ethernet and 802.1w Rapid
Spanning Tree Protocol (RSTP)
Tabletop mounting (as shipped), DIN rail with kit
P0973GE, or 19-inch rack mounted with kit
P0973GG.
RJ-45 connectors
 P0973GB - eight 100Base-FX ports with LC
connectors
 P0973HB - sixteen 100Base-FX ports with LC
connectors
 P0973HC - eight 100Base-FX ports and twelve
100Base-TX ports with LC/RJ-45 connectors
As well, each has two 1000Base-X uplink Gigabit
(SFP) ports, which can be populated with Mini-GBIC
uplink connector modules (P0973GH, P0973GJ, or
P0973FU).
This switch, part of the I-Series line of switches, is an
industrially hardened Ethernet switch especially
designed to handle networking in physically
demanding environmental conditions. I-Series
switches feature convection cooling, dc power, and
industrial-grade components that ensure continued
uptime. I-Series switches are unique for hardened
switches because they embed advanced security
features that protect the confidentiality, integrity and
availability of industrial automation applications.
PSS 21H-7C3 B4
Page 17
High-availability features include support for
redundant dc-power connections, rapid reconvergence (802.1w RSTP). I-Series switches
provide the automation industry with a fully hardened
switch without sacrificing features and security.
An I-series switch is powered via an external 24 V dc
power supply (P0922YU).
The switch allows high-performance, full-featured
Layer-2 Ethernet switching in small to medium-sized
network applications, as well as high-performance
direct end-station connectivity.
EXTERNAL POWER SUPPLY
Refer to DIN Rail Mounted Power Supply
(PSS 21H-2W3 B4) for the product specifications for
the FPS400-24 power supply (P0922YU).
INSTALLATION GUIDELINES
NOTE
When installing switches within the same
enclosure as I/A Series Control Processors,
it is recommended that the I-series switches
be utilized. These switches have been
developed for this purpose.
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
WARNING
Install only in accordance with the Local and
National Codes of the authorities having
jurisdiction over your site. Utilize proper
wiring method for all power input and output
wiring that complies with the governing
electrical codes in accordance with the
authority having jurisdiction over the Class I,
Div. 2 installations.
Class I, Div 2 installations require that all devices
connected to this product must be UL approved for
the area in which it is installed. Only UL approved
wiring with temperature ratings greater than 90°C
(194°F) are permitted for Class I, Div 2 installations
operating at temperatures up to 60°C (140°F)
ambient.
The dc power to the I-series switch must be provided
by a reliably grounded dc power source that
complies with the Safety Extra Low Voltage (SELV)
requirements of IEC 60950 based safety standards.
Use 14 to 20 AWG supply solid copper wires suitable
for 30°C (86°F) above surrounding ambient
temperature. The switch must be properly grounded
utilizing a 14 to 20 AWG cable to comply with
emission and immunity requirements. When installing
the switch, always make the ground connection first
and disconnect last. A readily accessible disconnect
device that is suitably approved and rated shall be
incorporated in the field wiring.
SWITCH HARDWARE CONFIGURATION
Table 6 lists the Industrial Fiber switch and the (IOM)
Input Output Modules that can interface with the
switch, increasing the switch's functionality and/or
port capacity. The uplink connectors (GBICs) are
added to the two 1000Base-X uplink Gigabit (SFP)
ports providing gigabit interface to The MESH
Network backbone.
PSS 21H-7C3 B4
Page 18
Table 6. I-Series Managed Switch Modules
Uplink Ports
(on Switch)
Switch
Description
Invensys
Part No.
Description
Uplink Connectors
(Add to Interfaces)
Description
Invensys
Part No.
24-port RJ-45 100Base-TX
P0973GA Two 1 Gb SFP
Copper managed Industrial
uplink ports,
switch with two SFP ports for
1000Base-X, for
Mini-GBIC modules.
Mini-GBIC modules
1 Gb uplink module P0973GJ - with MMF
1000Base-SX with Industrial Mini-GBIC
LC connectors
Compatible with
P0972WT - Refer to
Table 11 on page 45
to determine
maximum range for
your specific
application.
8-port LC MMF 100Base-FX P0973GB
Fiber managed Industrial
switch with two SFP ports for
Mini-GBIC modules.
1 Gb uplink module P0973GH -10 km
1000Base-LX with with SMF (6.2 mi)
LC connectors
Industrial Mini-GBIC
Compatible with
P0972WU
16-port LC MMF 100Base-FX P0973HB
Fiber managed Industrial
switch with two SFP ports for
Mini-GBIC modules.
1 Gb uplink module P0973FU - 80 km
1000Base-ZX with (49.6 mi) with SMF
LC connectors
Industrial Mini-GBIC
Compatible with
P0973FT
8-port LC MMF 100Base-FX P0973HC
Fiber and 12-port 100BaseTX managed Industrial switch
with two SFP ports for MiniGBIC modules.
1 Gb uplink module P0973JA - MMF;
1000Base-LX/LH
Refer to Table 11 on
with LC connectors page 45 to determine
maximum range for
your specific
application. Industrial
Mini-GBIC
Compatible with
P0972YQ.
PSS 21H-7C3 B4
Page 19
Table 7. I-Series Switch Mounting Kits and Power Cables
Description
Invensys Part No.
Table Top mount
N/A (part of unit)
I-series DIN rail mounting kit
P0973GE
I-series rack-mounting kit for racks 48.3 cm (19-inch)
P0973GG
24 V dc output Power cable assembly for I-series switch, when used with power
supply P09722YU
P0972RN
120 V ac input Power cable assembly for power supply P09722YU (83.8 cm (33 in)) P0926CM
120 V ac input Power cable assembly for power supply P09722YU (122 cm (48 in)) P0926TM
F U N C T I O N A L S P E C I F I C AT I O N S
I N D U S T R I A L F I B E R M A N A GE D S W I T C H ( P 0 9 7 3 GB )
Power
INTERNAL
dc Input power only
24 V dc external power
EXTERNAL
Supports connection for redundant power supply
POWER CONSUMPTION
29.76 Watts
MAXIMUM CURRENT
1.24A at 24V dc
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
TEMPERATURE
-40 to +60°C (-40to +140°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
OPERATIONAL SHOCK
50 G trapezoidal shock
Storage Conditions
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
PSS 21H-7C3 B4
Page 20
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk, DIN or Rack - 48.3 cm (19-inch) equipment
rack, 2U high
5.06 kg (11.13 lb)
Dimensions
Cable Connectors
SWITCH PORTS
LC fiber
UPLINK PORTS
SFP with LC fiber Mini-GBICs
HEIGHT
8.89 cm (3.5 in)
WIDTH
18.41 cm (7.25 in)
DEPTH
33.86 cm (13.33 in)
Vibration
Random: MIL-STD-810F
Vibration - IEC 60068-2-6
Shock - IEC 60068-2-27
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Humidity
47 CFR Parts 2 and 15, CSA C108.8, EN 55022, EN
55024, EN 61000-3-2, EN 61000-3-3, AS/NZS
CISPR 22, and VCCI V-3
IEC 60068-2-30
Standard EMC
FCC Part 15-Class A, ICES-003 Class A, BSMI,
VCCI-Class I,
CISPR 22-Class A, EN 55024, EN 55022B Class A
Industrial EMC
EN55011
Standard Safety
UL 60950-1, CSA 22.2, EN60950-1
Certification for Switch
The switch is certified for use in hazardous locations
within the guide lines of:
HAZARDOUS LOCATIONS:
ISA12.12.01 Class I, Div 2
CONTAMINATION
Class G1 (Mild) as defined in ISA Standard
S71.04
PSS 21H-7C3 B4
Page 21
( C - S E R I E S ) 2 6- G I G A B I T ( S F P ) P ORT M A N A G E D S W I T C H ( P 0 97 3K J )
FEATURES
The 26-Gigabit
features:
 Address Resolution Protocol (ARP) & ARP
(SFP(1))
Port managed switch
 24 1000Base-X Gigabit (SFP) and two 10G SFP
ports configurable as 1G uplink ports of nonblocking SFP Mini-GBIC connectivity
 Full duplex operation
 Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
 Port mirroring technology and diagnostics that
allow local network traffic to be redirected to an
external probe for detailed analysis
 Compliance with industry standards, including
IEEE 802.3u Fast Ethernet, 802.1w
 Rapid Spanning Tree Protocol (RSTP)
 Optional redundant power supply
 Shelf, desk, or 19-inch rack mounting.
It delivers extensive Layer 2/3/4 packet classification
and marking based on any of the following:
 MAC address
 Physical port
 IP address
 IP Protocol
 IP ToS/DSCP marking
 TCP/UDP port
 IP subnet
(1) Small Form Factor Pluggable
Redirect
INTRODUCTION
The 26-Gigabit (SFP) Port managed switch
(P0973KJ) provides twenty-six modular 1000Base-X
Gigabit (SFP) ports. All twenty-six ports can be
populated with Mini-GBIC uplink connector modules
listed in Table 8. The twenty-four 1000Base-X SFP
ports can be populated with the 100Base-FX MiniGBIC (P0973JE) module for device connectivity if the
switch is running on firmware 06.61.08.0013 or
greater.
The switch allows high-performance, full-featured
layer-2 Ethernet switching in small to medium-sized
network applications. It has been designed to be
utilized as an uplink switch in The MESH control
network.
OPTIONAL REDUNDANT POWER SUPPLY
See “REDUNDANT POWER SUPPLY (P0973BP)” on
page 29.
PSS 21H-7C3 B4
Page 22
INSTALLATION GUIDELINES
UPLINK/SWITCH INTERFACES
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
Table 8 “26-Gigabit (SFP) Port Managed Switch
(P0973KJ) and 24-Gigabit RJ-45 Port Managed
Switch (P0973LK) Interfaces” on page 26 lists the
26-Gigabit (SFP) Port switch and the uplink
interfaces that can be added to the switch. The
uplink connectors are added to specific uplink
interfaces.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) at the left, right, and rear of the
switch. Do not connect the switch to the ac
power source until instructed to do so later in the
installation process.
 Ambient temperature at the installation site must
be maintained between 0° and 50°C (32° to
122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
NOTE
Ports 25 and 26 of the 26-Gigabit (SFP) Port
managed switch (P0973KJ) have dual port
speeds of 1Gb or 10Gb. 10Gb speeds are
not currently supported on The MESH
control network.
PSS 21H-7C3 B4
Page 23
F U N C T I O N A L S P E C I F I C AT I O N S
2 6- G I G A B I T ( S F P ) P ORT M A N A G E D S W I T C H ( P 0 97 3K J )
Power
INTERNAL
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
Supports connection for redundant power supply
HEAT DISSIPATION
223.1 BTUs (65.4 watts)/hr
POWER CONSUMPTION
29 Watts
MAXIMUM CURRENT
1.5A
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to 50°C (32°F to 122°F)
RELATIVE HUMIDITY
5 to 95% (non-condensing)
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (non-condensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
5.075 kg (11.2 lbs)
Dimensions
Cable Connectors
UPLINK PORTS
RJ-45 copper or LC fiber
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.1 cm (17.36 in)
DEPTH
36.85 cm (14.5 in)
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Environmental
FCC 47 CFR Part 15 (Class A), ICES-003 (Class A),
EN 55022 (Class A), EN 55024,
EN 61000-3-2, EN 61000-3-3, AS/NZ CISPR-22
(Class A). VCCI V-3. CNS 13438 (BSMI),
2004/108/EC (EMC Directive)
2002/95/EC (RoHS Directive), 2002/96/EC (WEEE
Directive), Ministry of Information Order #39 (China
RoHS)
Product Safety
UL 60950-1, FDA 21 CFR 1040.10 and 1040.11,
CAN/CSA C22.2 No. 60950-1,
EN 60950-1, EN 60825-1, EN 60825-2,
IEC 60950-1, 2006/95/EC (Low Voltage Directive)
Location
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Contamination
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 24
( B - S E R I E S ) 2 4- G I G A B I T R J - 4 5 P O RT M A N A G E D S W I T C H ( P 0 9 7 3 L K )
FEATURES
 Physical port
The 24-Gigabit RJ-45 port managed switch features:
 IP address
 20 10/100/1000Base-TX Gigabit ports
configurable as 1G uplink ports
 4 Four optional 10/100/1000Base-TX or SFP(2)
1000Base-X Mini-GBIC ports for uplink (ISL)
connector modules
 SFP(2) ports for 1000Base-X Mini-GBIC uplink
(ISL) connector modules
 Full duplex operation
 Monitoring and configuration tasks via local
console port, or any SNMP/RMON based
management application.
 Port mirroring technology and diagnostics that
allow local network traffic to be redirected to an
external probe for detailed analysis
 Compliance with industry standards, including
IEEE 802.3u Fast Ethernet, 802.1w
 Rapid Spanning Tree Protocol (RSTP)
 Optional redundant power supply
 Shelf, desk, or 19-inch rack mounting.
It delivers extensive Layer 2/3/4 packet classification
and marking based on any of the following:
 MAC address
(2) Small Form Factor Pluggable
 IP Protocol
 IP ToS/DSCP marking
 TCP/UDP port
 IP subnet
 Routing Information Protocol (RIP v1/v2)
 Internet Control Message Protocol (ICMP)
 Address Resolution Protocol (ARP) & ARP
Redirect
 Dynamic Host Configuration Protocol (DHCP)
Relay
 Bootstrap Protocol (BOOTP) Relay
INTRODUCTION
The 24-Gigabit (RJ-45) Port managed switches
(P0973LK) provide twenty10/100/1000Base-TX
Gigabit ports. Four optional 10/100/1000Base-TX or
SFP ports that can be populated with 1000Base-X
Mini-GBIC uplink (ISL) connector modules listed in
Table 8. If an SFP port is populated with a Mini-GBIC
then the corresponding 1000Base-TX copper port
cannot be used.
The switches allow high-performance, full-featured
layer-2 Ethernet switching in small to medium-sized
network applications.
PSS 21H-7C3 B4
Page 25
OPTIONAL REDUNDANT POWER SUPPLY
See “REDUNDANT POWER SUPPLY (P0973BP)” on
page 29.
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for this switch. If the guidelines are
not followed, unsatisfactory network performance
may result.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) at the left, right, and rear of the
switch. Do not connect the switch to the ac
power source until instructed to do so later in the
installation process.
 Ambient temperature at the installation site must
be maintained between 0° and 50°C (32° to
122°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
UPLINK/SWITCH INTERFACES
Table 8 “26-Gigabit (SFP) Port Managed Switch
(P0973KJ) and 24-Gigabit RJ-45 Port Managed
Switch (P0973LK) Interfaces” on page 26 lists the
24-Gigabit RJ-45 Port switch and the uplink
interfaces that can be added to the switch. The
uplink connectors are added to specific uplink
interfaces.
NOTE
Ports 21-24 can be used as 1 Gigabit fix
copper or utilized as a SFP GBIC that can be
installed with fiber connectivity. If a SFP
GBIC is utilized, the corresponding fixed
(RJ-45) copper port will be disabled. Ports
21-24 should be reserved for ISL ports.
PSS 21H-7C3 B4
Page 26
Table 8. 26-Gigabit (SFP) Port Managed Switch (P0973KJ) and
24-Gigabit RJ-45 Port Managed Switch (P0973LK) Interfaces
Uplink Ports
(on Switch)
Switch
Description
26-Gigabit (SFP)
Port managed
switch
Invensys
Part No.
Description
Invensys
Part No.
P0973KJ
Twenty-six 1 Gb
uplink ports,
1000Base-X, for
Mini-GBIC modules
Uplink module
1000Base-SX with LC
connector
P0972WT - MMF - Refer
to Table 11 on page 45
to determine maximum
range for your specific
application.
P0973LK
Twenty-four 1 Gb
1000Base-TX ports
and four SFP ports for
1000Base-X
Mini-GBIC modules
Uplink module
1000Base-LX with LC
connector
P0972WU - 10 km
(6.2 mi) with SMF
Uplink module
1000Base-LX/LH with
LC connector
P0972YQ - MMF -Refer
to Table 11 on page 45
to determine maximum
range for your specific
application.
Uplink module
1000Base-ZX with LC
connector
P0973FT - 80 km
(49.6 mi) with SMF
Uplink module
1000Base-T with RJ-45
connectors
P0972YL - 100 m
(330 ft)
Bi-directional
downlink/uplink MiniGBIC Kit - includes both
P0973JB and P0973JC
modules
P0973JD(a) - 10 km
(6.2 mi) with SMF MiniGBIC Kit
100Mb MGBIC
100Base-FX device
interface module with LC
connectors
P0973JE - MMF - Refer
to Table 11 on page 45
to determine maximum
range for your specific
application.
-AND24-Gigabit (RJ-45)
Copper Port
managed switch
Description
Uplink Connectors
(Add to Interfaces)
PSS 21H-7C3 B4
Page 27
Table 8. 26-Gigabit (SFP) Port Managed Switch (P0973KJ) and
24-Gigabit RJ-45 Port Managed Switch (P0973LK) Interfaces (Continued)
Uplink Ports
(on Switch)
Switch
Description
26-Gigabit (SFP)
Port managed
switch
Invensys
Part No.
Description
Invensys
Part No.
P0973KJ
Twenty-six 1 Gb
uplink ports,
1000Base-X, for
Mini-GBIC modules
P0973KP(b) - 40 km
Bi-directional
downlink/uplink Mini(25 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KM and P0973KN
modules
P0973LK
Twenty-four 1 Gb
1000Base-TX ports
and four SFP ports for
1000Base-X
Mini-GBIC modules
(CONT.)
P0973KS(c) - 120 km
Bi-directional
downlink/uplink Mini(74.6 mi) S-SMF MiniGBIC Kit - includes both GBIC Kit
P0973KQ and P0973KR
modules
-AND24-Gigabit (RJ-45)
Copper Port
managed switch
(CONT.)
Description
Uplink Connectors
(Add to Interfaces)
(a) Kit P0973JD is comprised of two Mini-GBICs (P0973JB and P0973JC). P0973JC transmits “downstream” (from the core of the
network to the edge) uses the 1490 nm wavelength, and the “edge” P0973JB transmits “upstream” uses the 1310 nm wavelength.
(b) Kit P0973KP (40 km (25 mi)) is comprised of two Mini-GBICs (P0973KM and P0973KN). P0973KN transmits “downstream” (from the
core of the network to the edge) uses the 1490 nm wavelength, and the “edge” P0973KM transmits “upstream” uses the 1310 nm
wavelength over Simplex Single Mode Fiber (S-SMF).
(c) Kit P0973KS (120Km) is comprised of two Mini-GBICs (P0973KQ and P0973KR). P0973KR transmits “downstream” (from the core of
the network to the edge) uses the 1590 nm wavelength, and the “edge” P0973KQ transmits “upstream” uses the 1490 nm wavelength
over Simplex Single Mode Fiber (S-SMF) at a minimum distance of 30 km (19 mi).
PSS 21H-7C3 B4
Page 28
F U N C T I O N A L S P E C I F I C AT I O N S
2 4- G I G A B I T ( R J - 4 5 ) P O RT M AN A G E D S W I T C H ( P 0 9 7 3 L K )
Power
INTERNAL
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
Supports connection for redundant power supply
HEAT DISSIPATION
164 BTUs/hour
POWER CONSUMPTION
48 Watts
MAXIMUM CURRENT
2A Maximum
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to 50°C (32°F to 122°F)
RELATIVE HUMIDITY
5 to 95% (non-condensing)
TEMPERATURE
-40 to +70°C (-40 to +158°F)
RELATIVE HUMIDITY
5 to 95% (non-condensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
4.92 kg (10.85 lb)
Dimensions
Cable Connectors
UPLINK PORTS
RJ-45 copper or LC fiber
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.1 cm (17.36 in)
DEPTH
36.85 cm (14.5 in)
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Environmental
FCC 47 CFR Part 15 (Class A), ICES-003 (Class A),
EN 55022 (Class A), EN 55024,
EN 61000-3-2, EN 61000-3-3, AS/NZ CISPR-22
(Class A). VCCI V-3. CNS 13438 (BSMI),
2004/108/EC (EMC Directive)
2002/95/EC (RoHS Directive), 2002/96/EC (WEEE
Directive), Ministry of Information Order #39 (China
RoHS)
Product Safety
UL 60950-1, FDA 21 CFR 1040.10 and 1040.11,
CAN/CSA C22.2 No. 60950-1,
EN 60950-1, EN 60825-1, EN 60825-2,
IEC 60950-1, 2006/95/EC (Low Voltage Directive)
Location
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Contamination
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 29
RE D UN D A N T P O W ER SU P PLY ( P0 97 3B P)
Redundant Power Supply (P 097 3BP)
Features
Overview
The redundant power supply for the 24-Port Copper
(P0973JM), 24-Port Fiber (P0973JN), 8-Port Copper/
8-Port Fiber (P0973JP), 26-Gigabit (SFP) Port
(P0973KJ) and 24-Gigabit (RJ-45) Port (P0973LK)
managed switches features:
The 156 watt redundant power supply (P0973BP)
can supply redundant power for the P0973JM,
P0973JN, P0973JP, P0973KJ, or P0973LK
managed switches. It operates in a parallel capacity
with the switch’s internal power supply. In the event
of an ac power loss or failure of an internal power
supply, the redundant power supply supports the full
load of the switch without affecting network
operation.
 Support for up to eight P0973JM, P0973JN,
P0973JP, P0973KJ, or P0973LK managed
switches (one supply/switch)
 Desktop, shelf, or 19-inch rack mounting
 Up to 156 W of power per supply (with up to
eight supplies/chassis).
The (RPS) redundant power supply (P0973BP) must
be used with the (RPSC) Redundant Power Supply
Chassis (P0973BM/BN). This chassis does not have
AC power connections or electronics.
The P0973BN power supply chassis accommodates
two RPSes (P0973BP) which can support up to two
P0973JM, P0973JN, P0973JP, P0973KJ, or
P0973LK switches. The P0973BM power supply
chassis accommodates up to eight RPSes
(P0973BP) which can support up to eight P0973JM,
P0973JN, P0973JP, P0973KJ, or P0973LK
switches.
PSS 21H-7C3 B4
Page 30
Redundant Power Supply Chassis (P0 973BM) - Eigh t Slot
Redundant Power Supply Chassis (P0 973BN ) - Two Slot
PSS 21H-7C3 B4
Page 31
F U N C T I O N A L S P E C I F I C AT I O N S
RE D UN D A N T P O W ER SU P PLY ( P0 97 3B P)
Power
OUTPUT
102 W or 156 W continuous
AC INPUT RANGE
85-264 V ac Hz, 47 to 63 Hz
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
5 to +40°C (41 to +104°F)
RELATIVE HUMIDITY
5 to 90% (noncondensing)
TEMPERATURE
-30 to +73°C (-22 to +164°F)
RELATIVE HUMIDITY
5 to 90% (noncondensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Redundant power supply chassis (P0973BM for eight
RPS and P0973BN for two RPS)
1.75 kg (3.85 lb)
Dimensions
HEIGHT
19.6 cm (7.7 in)
WIDTH
5.2 cm (2.04 in)
DEPTH
25.7 cm (10.1 in)
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Location
(Applies to P0973BM with eight power supplies
installed and working with eight switches)
47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024;
AS/NZS CISPR 22, and VCCI V-3
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Product Safety
UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN
60950, and IEC 60950
Contamination
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 32
F U N C T I O N A L S P E C I F I C AT I O N S
R E D U N D A N T P O W E R S U P PLY C H A S S I S ( P 0 9 7 3 B M )
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack, 5U high
5.27 kg (11.6 lb)
Dimensions
Eight slots for redundant power supplies (P0973BP)
Power Supply Slots
HEIGHT
22.26 cm (8.77 in)
WIDTH
44 cm (17.3 in)
DEPTH
26.4 cm (10.4 in)
R E D U N D A N T P O W E R S U P PLY C H A SS I S ( P 0 97 3B N )
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
0.95 kg (2.09 lb)
Dimensions
Two slots for redundant power supplies (P0973BP)
HEIGHT
5.5 cm (2.2 in)
WIDTH
48.2 cm (19 in)
DEPTH
18 cm (7.0 in)
Power Supply Slots
PSS 21H-7C3 B4
Page 33
( S - S E R I E S ) S S A C H A S S I S M AN A G E D S W I T C H ( P 0 9 7 3 K K )
FEATURES
INTRODUCTION
The features of the SSA Chassis managed switch
(P0973KK) are:
The SSA Chassis managed switch provides fifty-two
SFP 1000Base-X 1Gb uplink ports.
 Up to 48 - 1000Base-X 1 Gb SFP uplink ports
 4-port 10G SFP uplink ports configurable as 1G
uplink ports
 Rapid Spanning Tree (RSTP), IEEE 802.1w
compatible
 Monitoring and configuration tasks via local port,
or SNMP-based management application
The switch allows high-performance, full-featured
Ethernet switching in small to medium-sized network
applications, as well as high-performance direct endstation connectivity.
Distributed switching architecture with redundant
processors and integral load-sharing redundant
power supplies make the SSA Chassis managed
switch extremely reliable.
 Distributed switching architecture for maximum
uptime
 No single point of failure - contains integral
redundant power supplies.
POWER SUPPLY
The chassis utilizes a 625 watt power supply
(ordered separately) that requires one separately
fused, 15-amp power circuit within 182 cm (6 ft) of
the power supply. For redundancy, a second supply
slot is available.
NOTE
Two separate branch circuits are required for
the redundant power supply. Requires two
15 A ac outlets independently fused within
182 cm (6 ft) of power supply, each outlet
uses a separate 15 A power circuit per
power supply.
PSS 21H-7C3 B4
Page 34
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for the SSA Chassis managed switch.
If the guidelines are not followed, unsatisfactory
network performance may result.
 The SSA Chassis managed switch may be
mounted in a 19” rack, such in the G50 Server
enclosure, discussed in G50 Server Enclosure
(PSS 21H-2X50 B4).
 If installed in an enclosure other than the G50
Server enclosure, be aware that the air flow for
the SSA Chassis managed switch is different
from other The MESH control network switches
and this may impact the air circulation in the
enclosure.
 To ensure proper ventilation and prevent
overheating, leave a minimum clearance space of
5.1 cm (2.0 in) of clearance on either side and in
the rear of the unit.
 To install the SSA Chassis managed switch as a
freestanding unit on a shelf, the shelf must be
able to adequately support the static weight of
the unit.
 The power supplies for the SSA Chassis
managed switch require two three-pronged
power receptacles capable of delivering the
current and voltage specified below. ac outlets on
independently fused circuits are required for each
power supply, and must be located less than 2 m
(6 ft) from the site. The power cord used and type
of outlet is dependent on the country. In the
United States, two power cords with NEMA 515P plugs are provided with each power supply.
 Ambient temperature at the air inlet for each
switch must be maintained between 5° and 40°C
(41° to 104°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
 To install the SSA Chassis managed switch as a
rack mounted unit using the SSA rail kit (shipped
with the SSA switch), ensure that the rack used
will support the unit and that the rack will remain
stable after installation.
The SSA Chassis switch can be mounted on a
desktop, or in three types of racks:
 Four-post rack
 Two-post rack (18 cm (7 in) posts)
 Two-post rack (7.6 cm (3 in) posts).
PSS 21H-7C3 B4
Page 35
F U N C T I O N A L S P E C I F I C AT I O N S
S S A C H A S S I S M AN A G E D S W I T C H ( P 0 9 7 3 K K )
Power
INTERNAL
Up to 2 ac Input power supplies (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
EXTERNAL
N/A
HEAT DISSIPATION
BTUs (65.4 watts)/hr
POWER CONSUMPTION
625 Watts
MAXIMUM CURRENT
8A
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
5°C to 40°C (41°F to 104°F)
RELATIVE HUMIDITY
5% to 90% (non-condensing)
TEMPERATURE
-30°C to 73°C (-22°F to 164°F)
RELATIVE HUMIDITY
5% to 90% (non-condensing)
P H Y S I C A L S P E C I F I C AT I O N S
Mounting
Mass - Approximate
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack,1U high
11.79 kg (26 lb)
Dimensions
Cable Connectors
UPLINK PORTS
RJ-45 copper or LC fiber
HEIGHT
4.4 cm (1.7 in)
WIDTH
44.7 cm (17.6 in)
DEPTH
59.43 cm (23.4 in)
Vibration
Vibration - IEC 68-2-36, IEC 68-2-6
Shock - IEC 68-2-29
Drop - IEC 68-2-32
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
the EN 60825 and 21 CFR 1040.10 standards.
FCC 47 CFR Part 15 (Class A), ICES-003 (Class A),
EN 55022 (Class A), EN 55024, EN 61000-3-2, EN
61000-3-3, AS/NZ CISPR-22 (Class A). VCCI V-3.
CNS 13438 (BSMI), 2004/108/EC (EMC Directive)
Environmental
Product Safety
Location
Safety: UL 60950-1, FDA 21 CFR 1040.10 and
1040.11, CAN/CSA C22.2, No. 60950-1, EN 609501, EN 60825-1, EN 60825-2, IEC 60950-1,
2006/95/EC (Low Voltage Directive)
Modules which support laser connections also meet
2002/95/EC (RoHS Directive), 2002/96/EC (WEEE
Directive), Ministry of Information Order #39 (China
RoHS)
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Contamination
Class G1 (Mild) as defined in ISA Standard S71.04
PSS 21H-7C3 B4
Page 36
( S - S E R I E S ) S 4 C H A S S I S S W I T C H ( P 0 97 3K D )
Slot 4
Slot 3
(Not Used)
Slot 2
Slot 1
Power Supplies
FEATURES
INTRODUCTION
The features of the S4 Chassis managed switch
(P0973KD) are:
The S4 Chassis managed switch provides up to one
hundred ninety two SFP uplink ports depending on
the number of blades and modules installed.
 Up to 192 1Gb SFP uplink ports depending on
the choice of modules
 Selectable switch modules/uplink modules and
interfaces (see Table 9, “S4 Chassis Switch
Modules/Uplink Modules,” on page 38)
 Rapid Spanning Tree (RSTP), IEEE 802.1w
compatible
 Monitoring and configuration tasks via local port,
or SNMP-based management application
 Distributed switching architecture for maximum
uptime
 No single point of failure - contains integral
redundant power supplies.
The S4 Chassis managed switch consists of three
usable slots within a 4-slot chassis with four empty
power supply locations and a front mounted fan
assembly. The 3-slots can be populated with
Ethernet blades/modules, depending on the needs of
the user.
Slot 2 in the switch must be populated with an S4
S-series Network I/O Fabric module (P0973KG) for
switch operations. The I/O Fabric module is the
master blade for the switch, controlling the other slot
locations. To achieve proper failover in the event of
an I/O Fabric module failure, Slot 3 cannot be
populated.
The switches allow high-performance, full-featured
Ethernet switching in medium to large-sized network
applications.
PSS 21H-7C3 B4
Page 37
Direct end-station connectivity is possible when
using the 100Mb GBIC (P0973JE).
NOTE
S4 Chassis managed switches requires a
minimum of two power supplies installed. If
the P0973KE power supply is utilized then a
20-amp branch circuits is required. If the
P0973LJ power supply is being utilized then
a 15-amp branch circuits can be used.
POWER SUPPLY
The S4 chassis utilizes up to four power supplies
(ordered separately) that requires one separately
fused 20-amp or 15-amp power circuit within 182
cm (6 ft) of the power supply. For redundancy, four
supply slots are available.
INSTALLATION GUIDELINES
The following guidelines must be observed when a
site is selected for the S4 Chassis managed switch. If
the guidelines are not followed, unsatisfactory
network performance may result.
 The S4 Chassis managed switch may be
mounted in a 19” rack, such in the G50 Server
enclosure, discussed in G50 Server Enclosure
(PSS 21H-2X50 B4).
 If installed in an enclosure other than the G50
Server enclosure, be aware that the air flow for
the S4 Chassis managed switch is different from
other The MESH control network switches and
this may impact the air circulation in the
enclosure.
 For proper cooling, there must be a minimum
amount of clearance 152 mm (6 in) behind the
chassis and 51 mm (2 in) of clearance on either
side of the chassis.
 If installing the S4 Chassis managed switch as a
freestanding unit on a shelf, ensure that the shelf
can support a minimum weight of approximately
24.7 kg (54.45 lb) per fully loaded chassis plus
the weight of the connected network cables. The
weight includes the chassis, fan tray, two power
supplies, and three modules.
 If installing the S4 Chassis managed switch in an
equipment rack, ensure that the rack can support
and remain stable with the chassis installed.
 Each P0973KE ac power supply requires a three-
pronged power receptacle capable of delivering
the current and voltage specified below. An ac
outlet on a separately fused circuit is required for
each P0973KE supply to provide power
redundancy, and must be located within 1.8 m (6
ft) from the site. The power cord used and type of
outlet is dependent on the country. In the United
States, a power cord with a NEMA 5-20P plug is
provided with each P0973KE supply.
 Ambient temperature at the air inlet for each
switch must be maintained between 5° and 40°C
(41° to 104°F). Temperature changes must be
maintained within 10°C (18°F) per hour.
SWITCH/UPLINK MODULES
Table 9 lists the type of Ethernet switch modules and
optional uplink modules which are compatible with
the S4 Chassis managed switch. This managed
switch has three usable slots for switch modules
(blades).
PSS 21H-7C3 B4
Page 38
Table 9. S4 Chassis Switch Modules/Uplink Modules
Switch Modules
Description
(Slot 2 only)
Invensys
Part No.
P0973KG
Plug-in S150 I/O
Fabric switch
module with 2
expansion slots for
Network Option
Modules
(Slot 1 or 4 only)
Plug-in S130 I/O
switch module with
expansion slot for
Network Option
Modules
P0973KF
Uplink Modules
(add to switch module)
Description
1 Gb uplink Network
Option Module with
12 SFP ports
Invensys
Part No.
Uplink Connectors
(add to uplink module)
Description
P0973KH Uplink module
1000Base-SX
with LC
connectors
Invensys
Part No.
P0972WT - MMF Refer to Table 11
on page 45 to
determine
maximum range for
your specific
application.
Uplink module
1000Base-LX/LH
with LC
connectors
P0972YQ - MMF Refer to Table 11
on page 45 to
determine
maximum range for
your specific
application.
Uplink module
1000Base-LX
with LC
connectors
P0972WU - 10 km
(6.2 mi) with SMF
Uplink module
1000Base-ZX
with LC
connector
P0973FT(a) - 80 km
(49.6 mi) with SMF
P0972YL - 100 m
Uplink module
1000Base-T with (330 ft)
RJ-45 connectors
PSS 21H-7C3 B4
Page 39
Table 9. S4 Chassis Switch Modules/Uplink Modules (Continued)
Switch Modules
Description
(Slot 2 only)
Invensys
Part No.
P0973KG
Plug-in S150 I/O
Fabric switch
module with 2
expansion slots for
Network Option
Modules
(Slot 1 or 4 only)
Plug-in S130 I/O
switch module with
expansion slot for
Network Option
Modules
P0973KF
Uplink Modules
(add to switch module)
Description
1 Gb uplink Network
Option Module with
12 SFP ports
(Continued)
Invensys
Part No.
Uplink Connectors
(add to uplink module)
Description
P0973KH Bi-directional
(Cont.)
downlink/uplink
Mini-GBIC Kit includes both
P0973JB and
P0973JC
modules
Invensys
Part No.
P0973JD(b) - 10
km (6.2 mi) SMF
Mini-GBIC Kit
100Base-TX with
LC connectors
P0973JE - MMF
Bi-directional
downlink/uplink
Mini-GBIC Kit includes both
P0973KM and
P0973KN
modules
P0973KP(c) 40 km (25 mi) SSMF Mini-GBIC Kit
Bi-directional
downlink/uplink
Mini-GBIC Kit includes both
P0973KQ and
P0973KR
modules
P0973KS(d) 120 km (74.6 mi)
S-SMF Mini-GBIC
Kit
(a) It is not recommended to use the P0973FT MGBIC over distances less than 8 km (5.0 mi).
(b) Kit P0973JD is comprised of two Mini-GBICs (P0973JB and P0973JC). P0973JC transmits “downstream” (from the core of the network
to the edge) uses the 1490 nm wavelength, and the “edge” P0973JB transmits “upstream” uses the 1310 nm wavelength.
(c) Kit P0973KP (40 km (25 mi)) is comprised of two Mini-GBICs (P0973KM and P0973KN). P0973KN transmits “downstream” (from the
core of the network to the edge) uses the 1490 nm wavelength, and the “edge” P0973KM transmits “upstream” uses the 1310 nm
wavelength over Simplex Single Mode Fiber (S-SMF).
(d) Kit P0973KS (120Km) is comprised of two Mini-GBICs (P0973KQ and P0973KR). P0973KR transmits “downstream” (from the core of
the network to the edge) uses the 1590 nm wavelength, and the “edge” P0973KQ transmits “upstream” uses the 1490 nm wavelength
over Simplex Single Mode Fiber (S-SMF) at a minimum distance of 30 km (19 mi).
PSS 21H-7C3 B4
Page 40
F U N C T I O N A L S P E C I F I C AT I O N S
S 4 CH AS SI S S W I T CH ( P0 97 3K D )
Standards Supported
Input (Voltage/Current) at Output Power
IEEE 802.1q, 802.1d, 802.1p, 802.1w, 802.1x,
802.3, 802.3ad
Fast Ethernet: IEEE 802.3u, 100Base-FX
Gigabit Ethernet: IEEE 802.3z, 1000Base-T
P0973KE
20A, 100-240VAC input, (1200/1600W)
P0973LJ
15A, 100-240VAC input, (930/1600W)
Fault Tolerance
SWITCH MODULES
Independent, hot-swappable modules
POWER SUPPLIES
1:1 redundant integral supplies
Number of 1 Gb SFP Uplink ports (module
configuration dependent)
Up to 192
Link Power Budget
The maximum drive distance depends on the quality
of the installed single-mode and multi-mode fiberoptic cable segment. Use the link power budget to
calculate the maximum cable length of the attached
segment. The link power budget must not be
exceeded.
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
TEMPERATURE
5°C to 40°C (41°F to 104°F)
RELATIVE HUMIDITY
5 to 90% (noncondensing)
Storage Conditions
TEMPERATURE
-30°C to 73°C (-22°F to 164°F)
RELATIVE HUMIDITY
5 to 90% (noncondensing)
PSS 21H-7C3 B4
Page 41
P H Y S I C A L S P E C I F I C AT I O N S
S4 CHASSIS MANAGED SWITCH (P0973KD)
Mounting
Cables
Desk or Enclosure - 48.3 cm (19-inch) equipment
rack, 9U high
Chassis Dimensions - Nominal
HEIGHT
40 cm (15.75 in)
WIDTH
44.7 cm (17.6 in)
DEPTH
47.32 cm (18.63 in)
COPPER
1000Base-T, RJ-45
FIBER
1000Base-SX, 1000Base-LX, 1000Base-LX/LH,
1000Base-BX, or 1000Base-ZX LC connector
MEDIA TYPE
MMF (62.5 µm)/SMF (9 µm)), S-SMF (9 µm) or
STP CAT5 cables
Mass - Approximate
CHASSIS
24.7 kg (54.45 lb)
R E G U L AT ORY C O M PL I A N C E A N D C E RT I F I C AT I O N
Electromagnetic Compatibility (EMC)
Location
47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,
EN 55022, EN 61000-3-2,
EN 61000-3-3, EN 55024, AS/NZS CISPR 22, VCCI
V-3
UL/UL-C listed as suitable for use in ordinary
locations and meets ordinary safety standards for fire
and shock hazards.
Product Safety
Class G1 (Mild) as defined in ISA Standard S71.04
UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN
60950, IEC 60950
Modules which support laser connections also meet
the EN 60825 and 21 CFR 1040.10 standards.
Contamination
PSS 21H-7C3 B4
Page 42
M E DI A C O NV ERT E R 10 0B A SE- F X T O 1 00 BA SE - T X ( P0 97 2X H _ D )
Front View
FEATURES
INTRODUCTION
The features of the Media Converter (P0972XH) are:
The Media Converter (P0972XH) supports mixed
media networks by enabling copper-to-fiber media
conversion. It includes auto-recovery to automatically
restore link on the fiber line after a link loss event.
Auto-recovery works in conjunction with Link Loss
Return and Link Loss Carry Forward to identify the
loss of a remote network connection. It’s impact
resistant enclosure is made of high durability, fade
resistant plastic.
 Copper RJ-45 to MT-RJ fiber media conversion
 100Mbps speed adaptation
 Multimode fiber up to 2 km
 Link Loss Carry Forward, (LLCF) and Link Loss
Return (LLR) aids in troubleshooting a remote
network connection for all fiber optic ports
 Auto-Recovery restarts fiber link between two
back-to-back line cards after a link loss event
 MDI-II to MDI-X switch eliminates the need for
crossover cables on twisted-pair ports.
PSS 21H-7C3 B4
Page 43
F U N C T I O N A L S P E C I F I C AT I O N S
M E DI A C O N V ERT E R 10 0B A SE- F X T O 1 00 BA SE - T X ( P0 97 2X H _ D )
Link Length
Power Consumption
MMF, 2 km (1.25 mi)
CAT 5 cable, 100 m (330 ft)
10 W
Power Internal
ac Input power (auto-sensing)
100 V ac to 240 V ac, 50 to 60 Hz
E N V I R O N M E N TA L S P E C I F I C AT I O N S
Operating Conditions
Storage Conditions
TEMPERATURE
0 to +50°C (32 to + 132°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
TEMPERATURE
-25 to +70°C (-12 to +158°F)
RELATIVE HUMIDITY
5 to 95% (noncondensing)
P H Y S I C A L S P E C I F I C AT I O N S
Dimensions - Nominal (19-inch Rack Width)
HEIGHT
26 mm (1.06 in)
WIDTH
70 mm (2.76 in)
DEPTH
97 mm (3.83 in)
Mounting
Desk, shelf, or wall mount
Mass - Approximate
0.55 kg (1.2 lb)
PSS 21H-7C3 B4
Page 44
RECOMMENDED SWITCH TYPES PER ENVIRONMENT
Table 10 lists the types of switches which are
recommended, based on the operating conditions in
your installation site.
Table 10. Switch Types Recommended Per Installation Environment
Operating Conditions @ Site
Temperature Range:
5 to +40°C (41 to +104°F) - for S-Series
switches
Switch Types Supported
All currently qualified switches
All currently qualified GBICs
0 to +50°C (32 to +122°F) - for A-Series and
C-Series switches
Relative Humidity:
5 to 90% (non-condensing)
Temperature Range:
-40 to +60°C (-40 to +140°F) - for I-Series
switches
Relative Humidity:
5 to 95% (non-condensing)
Operational Shock:
50 G trapezoidal shock
P0973GA, P0973GB, P0973HB, P0973HC switches
Includes GBICs (P0973GJ, P0973JA, P0973GH, and
P0973FU)
NOTE: When installing switches within the same enclosure
as I/A Series Control Processors, it is recommended that
the I-series switches (P0973GA/GB/HB/HC) be utilized.
OPERATING RANGE FOR MINI-GBIC UPLINK CONNECTOR MODULES
Table 11 lists the operating ranges for the Mini-GBIC
uplink connector modules that can be used with The
MESH network switches. Refer to the sections above
for the Mini-GBIC modules which can be used which
each switch type.
PSS 21H-7C3 B4
Page 45
Table 11. Operating Range for Mini-GBIC Uplink Connector Modules(a)
Modal Bandwidth
Product Part
Number(b)
P0972WT and
P0973GJ
P0972YQ and
P0973JA
Cable Type
62.5µm
Light
Wavelength
Min. (Meters)
Max. (Meters)
160
2
220
62.5µm
200
2
275
50µm
400
2
500
50µm
500
2
550
160
2
2000
400
2
1000
62.5µm
850
MHz/km
Range
1310
50µm
P0972WU and 9-10µm
P0973GH
1310
-
-
10000
P0973FT(c) and 9-10µm
P0973FU
1550
-
-
80000
P0973JB(d)
9µm
1310/1490
-
-
10000
P0973JC(d)
9µm
1490/1310
-
-
10000
P0973JE(e)
62.5µm
1310
160
2
2000
400
2
1000
50µm
P0973KM(d)
9µm
1310/1490
-
5000
40000
P0973KN(d)
9µm
1490/1310
-
5000
40000
P0973KQ(d)
9µm
1490/1590
-
30000
120000
P0973KR(d)
9µm
1590/1490
-
30000
120000
(a) Transmission distances are provided as a nominal guide only. Refer to the optical specifications and the specific characteristics
of your fiber installation to determine targeted distances.
(b) Industrial MGBIC to be used with I-series industrial switch (P0973GA) with thermal limits of -40 to +60°C (-40 to +140°F).
All other MGBICs are thermal rated at 0 to +50°C (32 to +122°F).
(c) It is not recommended to use the P0973FT MGBIC over distances less than 8 km (5.0 mi).
(d) P0973JB/JC, P0973KM/KN and P0973KQ/KR are bi-directional Mini-GBICs. Both upstream and downstream switches
transmit on the same fiber but at different frequencies. When ordering these Mini-GBICs, you must acquire a matching pair, one
of each type. For a matching pair, order kits P0973JD (10 km (6.2 mi)), P0973KP (40 km (25 mi)), or P0973KS (120 km (74.6 mi))
which include one of each of the required modules.
(e) This Mini-GBIC (P0973JE) is not to be used as an uplink (ISL) port. This Mini-GBIC has been qualified to be used for an end
device (CP, ATS, FCM, workstation, etc.) 100Mb switch port.
PSS 21H-7C3 B4
Page 46
NETWORK SIZING (SWITCH SIZING)
The following tables provide suggestions for sizing
requirements, depending on your network. For more
complete sizing guidelines, refer to
The MESH Control Network System Planning and
Sizing (B0700AX).
Table 12. Network Sizing (Switch Sizing) For Small/Medium Networks
Small Networks
Medium Networks
2-8 Switches (<224 ports)
8-24 Switches (<600 ports)
Topology
Topology
Star
Tree
Star
Tree
Root Switches
Recommended
Root/Core Switches
Recommended
Root Switches
Recommended
Root/Core Switches
Recommended
P0973KK, P0973KJ, or
P0973LK
All switches, except those
Not Recommended
P0973KK, P0973KJ, or
P0973LK
P0973KK, P0973KJ, or
P0973LK
Root Switches
Not Recommended
Root Switches
Not Recommended
Root Switches
Not Recommended
Root Switches
Not Recommended
P0972WP/YC,
P0973JM/JN/JP, and
P0973GA/GB/HB/HC
P0972WP/YC and
P0973GA/GB/HB/HC
P0972WP/YC,
P0973JM/JN/JP, and
P0973GA/GB/HB/HC
P0972WP/YC, and
P0973GA/GB/HB/HC
Table 13. Network Sizing (Switch Sizing) For Large/Extra-Large Networks
Large Networks
Extra-Large Networks
20 – 72 Switches (<1700 ports)
> 54 Switches
Topology
Topology
Star
Tree
Star
Tree
Root Switches
Recommended
Root/Core Switches
Recommended
Root Switches
Recommended
Root/Core Switches
Recommended
P0973KK or P0973KD
P0973KJ, P0973LK,
P0973KK, or P0973KD
P0973KD
Network <190 switches
P0973KJ, P0973LK,
P0973KK, or P0973KD
Root Switches
Not Recommended
Root Switches
Not Recommended
Root Switches
Not Recommended
Root Switches
Not Recommended
P0972WP/YC,
P0973JM/JN/JP, and
P0973GA/GB/HB/HC
P0972WP/YC,
P0973JM/JN/JP, and
P0973GA/GB/HB/HC
All (except above listed)
P0972WP/YC,
P0973JM/JN/JP, and
P0973GA/GB/HB/HC
PSS 21H-7C3 B4
Page 47
System Configuration Features
The following table compares the features and protections available in the three available network
configurations.
Table 14. System Configuration Features
Standard Configuration
Security Enhanced Configuration
Network's ability to recovery from a “Spanning Tree Failure” event.
FEATURE: Rapid Spanning Tree and Loop Protection
Algorithm (LPA)
FEATURE: Loop Detection Policy (LDP) and Loop
Protection Algorithm (LPA)
“STP Loop (Data Storm)” protected network if LPA is
deployed
“STP Loop (Data Storm)” loop detection
(Sub-second recovery from event)
Switches Recommended
Switches Recommended
All switches, (V-series switches not supported, All
switches within the network must be running latest
firmware release)
P0973KK and P0973KD (at root and core)
PSS 21H-7C3 B4
Page 48
Invensys
10900 Equity Drive
Houston, TX 77041
United States of America
http://www.invensys.com
Global Customer Support
Inside U.S.: 1-866-746-6477
Outside U.S.: 1-508-549-2424 or contact
your local Invensys representative.
Website: http://support.ips.invensys.com
Invensys, Foxboro, I/A Series, and the Invensys logo are
trademarks of Invensys plc, its subsidiaries, and affiliates.
All other brands and product names may be the
trademarks of their respective owners.
Copyright 2004–2013 Invensys Systems, Inc. All rights
reserved. Unauthorized duplication or distribution is strictly
prohibited.
MB 21A
0713
Download PDF