Bosch PRS-1AIP1 Technical data

Bosch PRS-1AIP1 Technical data

IP Audio Interface

PRS-1AIP1

en

Operating Manual

IP Audio Interface

Table of contents

5.4

5.5

6

6.1

6.2

6.2.1

6.2.2

4.5.1

4.6

4.7

4.8

5

5.1

5.2

5.3

3.4.1

3.4.2

4

4.1

4.2

4.3

4.4

4.5

6.2.3

6.2.4

6.2.5

6.2.6

6.2.7

6.2.8

6.2.9

6.2.10

6.2.11

1

2

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.7.1

3

3.1

3.2

3.3

3.4

Bosch Security Systems B.V.

Important Safety Instructions

Short information

Purpose

Digital document

Intended audience

Related documentation

Alerts and notice signs

Conversion tables

Disclaimers

Bosch Security Systems B.V.

System overview

Application

Key product features

Package content

Product view

Front view

Rear view

Installation

Mechanical installation

Network (step 1)

Audio Outputs (step 2)

Power supply (step 3)

IP address (step 4)

No DHCP server is found

Audio Inputs 1/2

Control Inputs

Control Outputs

Connection options

Unicast (point to point)

Multiple Unicast

Broadcast

Multicast

Re-broadcast

Configuration

Connect to web browser

Configuration page

Network

Streaming

Partner Table

Outgoing Route Table

Control

Audio Settings

Supervision

Control Input Mapping Table

Control Output Mapping Table

Serial (RS-232/RS-485)

SNMP

Operating Manual

Table of Contents | en

3

8

8

9

8

8

9

10

12

6

6

6

6

6

5

6

7

7

7

13

13

13

13

14

14

14

14

12

12

12

12

12

29

30

31

32

20

22

23

24

27

16

17

18

19

15

15

16

2013.03 | V2.0 |

4

en | Table of Contents

9.1

9.2

9.3

9.4

8

9

7.1.5

7.1.6

7.1.7

6.2.12

6.2.13

6.2.14

6.2.15

7

7.1

7.1.1

7.1.2

7.1.3

7.1.4

Security

Default settings

Configuration view

Update

Operation

Status page

Control Inputs (1..8)

Control Outputs (1..8)

Audio

Codec

Power, Fault & Temperature

Last Caller

Restart Page

Maintenance

Technical data

Electrical

Mechanical

Environmental conditions

EMC and Safety

IP Audio Interface

39

39

40

40

40

40

41

41

33

34

35

36

39

42

43

43

44

44

45

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

1

Important Safety Instructions | en

5

Important Safety Instructions

The following important safety instructions are applicable to the PRS‑1AIP1 IP Audio Interface apparatus.

– Read these instructions.

– Keep these instructions.

– Heed all warnings.

– Follow all instructions.

– Do not use this apparatus near water.

– Only clean the apparatus with a dry cloth.

– Do not block any ventilation openings.

– Always install the apparatus according to Bosch installation instructions.

– Do not install the apparatus near any heat sources, for example: radiators, heat registers, stoves or other apparatus (including amplifiers) that generate heat.

– Protect the power supply cord from damage. For example: being walked on, pinched near the plug or from stress at the point where the power supply cord exits from the apparatus.

– Only use the apparatus with attachments and accessories supplied or recommended by

Bosch.

– This apparatus should only be serviced by qualified service personnel.

– If the apparatus has been damaged, servicing will be required. This includes damage caused by: liquid spillage or objects falling into the apparatus and/or the apparatus being exposed to rain or moisture. The apparatus must also be serviced if it does not function normally, it has been dropped and/or if there is damage to the power supply cord and plug.

– To prevent a risk of electrical shock, do not attempt to service the apparatus yourself.

Opening or removing the apparatus covers may expose you to dangerous voltages or other hazards.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

6

en | Short information

2

2.1

2.2

2.3

2.4

2.5

!

IP Audio Interface

Short information

Purpose

The purpose of this manual is to provide information required for installing, configuring, operating and maintaining the PRS‑1AIP1 IP Audio Interface.

Digital document

This manual is also available as a digital document in the Adobe Portable Document Format

(PDF).

Intended audience

This manual is intended for installers and users of a PRS‑1AIP1 IP Audio Interface.

Related documentation

Plena Voice Alarm System Operating Manual and Praesideo Public Address and Emergency

Sound System Installation and User Instruction manual.

Alerts and notice signs

The following alerts and notices are used in this manual. The alert type is closely related to the effect that may be caused if it is not observed.

Caution!

The equipment or the property can be damaged, or persons can be lightly injured if the alert is not observed.

In this manual a ‘notice’ is used to provide tips, or to give some extra information:

Notice!

Alert containing additional information. Usually, not observing a ‘notice’ does not result in damage to the equipment or personal injuries.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

2.6

2.7

2.7.1

Short information | en

7

Conversion tables

In this manual, SI units are used to express lengths, masses, temperatures, etc. These can be converted to non-metric units using the following information.

Non-metric unit SI unit

1 in = 25.4 mm

1 in = 2.54 cm

1 ft =

1 mi =

0.3048 m

1.609 km

SI unit

1 mm =

1 cm =

1 m =

1 km =

Non-metric unit

0.03937 in

0.3937 in

3.281 ft

0.622 mi

Non-metric unit SI unit

1 lb = 0.4536 kg

Non-metric unit SI unit

1 psi = 68.95 hPa

Disclaimers

SI unit

1 kg =

SI unit

1 hPa (= 1 mbar) =

Non-metric unit

2.2046 lb

Non-metric unit

0.0145 psi

Bosch Security Systems B.V.

Although every effort has been made to ensure the information and data contained in these manual is correct, no rights can be derived from the contents.

Bosch Security Systems B.V. disclaim all warranties with regard to the information provided in these instructions.

In no event shall Bosch Security Systems B.V. be liable for any special, indirect or consequential damages whatsoever resulting from loss of use, data or profits, whether in action of contract, negligence or other tortuous action, arising out of or in connection with the use of the information provided in these Installation and User Instructions.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

8

en | System overview

3

3.1

3.2

3.3

IP Audio Interface

System overview

Application

The PRS‑1AIP1 IP Audio Interface is a universal, Internet Protocol based audio device supporting VoIP and Audio over IP applications. It is used for bridging audio and contact closures over long distance LAN and WAN networks. It extends and interfaces to e.g.

Praesideo and non network based traditional public address systems, like Plena, without the need for a PC during operation.

The device has analog audio line inputs and line outputs for easy interfacing, it has optional pilot tone supervision and generation for emergency sound purposes. One audio input can be switched to microphone sensitivity with built‑in microphone supervision.

Control inputs and outputs can be used to set up an audio connection to start a remote call, but also to pass remote fault events to e.g. a system controller. Also, the control inputs offer cable and connection supervision, and can activate (remote) control outputs.

Key product features

Some key product features are:

– Digital audio transmission between public address systems on remote locations

– Designed to comply to international standards for emergency sound systems

– Supervised control inputs and control outputs

– A single unit can act as transmitter, receiver or both

– Installation and configuration via standard web browser

– Support for re‑broadcasting to extend the system size

– Built‑in configurable audio delay

Package content

The package contains:

– PRS‑1AIP1 IP Audio Interface

– CD with software and Installation and User Instructions

– Power supply for universal input voltage

– Screw block terminals (4 x 8 pin, 6 x 3 pin)

– Label stickers for screw block terminals

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

3.4

3.4.1

Product view

Front view

Shows the controls and indicators on the front panel.

System overview | en

9

1 2

Figure 3.1: Front view

1 Reset button

2

3

3

Green and red status

LEDs

Green LEDs (1...8) for control input status

– Press this recessed button briefly (1..3 seconds) to reset and start-up the device

– If you press it until the red LED (2) flashes (between 5 and 10 seconds) the device will be reset to factory defaults, and configuration settings will be lost. The network settings will not be lost

The status LEDs show the device status. The following modes exist:

Normal operation (power ON and no Errors)

– Green: ON

– Red: OFF

Searching IP address

– Green flashes five times, pauses four times, repeating

– Red flashes continuously

No application software loaded/Reset status

– Green: ON

– Red: flashes

Error detection

– Red: ON

– Green flashes five times: corrupt application loaded or

IP address conflict

– Green flashes three times: network hardware could not be initialized or a corrupt MAC address

The status LEDs correspond to the control inputs with the same number.

– All ON: searching for IP address or all inputs activated

– All OFF: IP address found and network connection established and all inputs deactivated

– One or more ON: one or more inputs activated

– One or more slow flashing: open input circuit(s), while supervision is enabled

– One or more fast flashing: shorted input circuit(s), while supervision is enabled

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

10

en | System overview

3.4.2

Rear view

Shows the connections on the rear panel.

4 6

8 10

1 8 1 8 1 3 1 3

12

IP Audio Interface

13 14 15

1 3

2013.03 | V2.0 |

5

Figure 3.2: Rear view

7

4

7

Control Outputs 1..4

5

6

7

8

9 11 16 17

Control Outputs 5..8

Control Inputs 1..4

Control Inputs 5..8 and Fault Relay out

Audio Output 2

Operating Manual

Default: open contacts (voltage free relay contact).

– 1-2: CO1

– 3-4: CO2

– 5-6: CO3

– 7-8: CO4

Default: open contacts (voltage free relay contact).

– 1-2: CO5

– 3-4: CO6

– 5-6: CO7

– 7-8: CO8

Default: open contacts (non isolated, 0 is connected to ground).

– 1-2: CI1

– 3-4: CI2

– 5-6: CI3

– 7-8: CI4

Default: open contacts (non isolated, shared 0 is connected to ground, internal pull-up current source).

– 1-2: CI5

– 3-4: CI6

– 5-6: CI7

– 7-8: CI8

Fault Relay out

Default (no fault): open contacts (voltage free relay contact).

– 7-8: Fault contact

Balanced, line level with pilot tone generation.

– 1: -

– 2: ground

– 3: +

Bosch Security Systems B.V.

IP Audio Interface

9

10

11

12

13

14

15

Ethernet 2 (back-up connection for redundancy)

RS 485 bus

16

17

Audio Output 1

Audio Input 2

Audio Input 1

RS 232 serial port

Ethernet 1

Back-up power supply input

Mains power supply input

System overview | en

11

Balanced, line level.

– 1: -

– 2: ground

– 3: +

Balanced, line level with pilot tone detection.

– 1: -

– 2: ground

– 3: +

Balanced, microphone/line level, microphone supervision.

– 1: -

– 2: ground

– 3: +

D-Sub, 9-pole male.

RJ45 for network connection 10/100

Mbps with status indicators.

– Green ON: network connection established

– Green OFF: no network connection

– Yellow ON/flashing: data communication

– Yellow OFF: no data communication

RJ45 for network connection 10/100

Mbps with indicators as for Ethernet 1.

– 1: A (TxD-/RxD-)

– 2: C (reference). Connected via a

100 ohm resistor to the ground, which is connected to the negative input terminal of the power supply

– 3: B (TxD+/RxD+)

With battery under-voltage detection.

– 1: +

– 2, 3: ground

With mains power failure detection.

– Centre: +

– Ring: ground

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

12

en | Installation

4

4.1

4.2

4.3

4.4

4.5

IP Audio Interface

Installation

The following installation sections guide you through the hardware and network installation

process. Refer to the connection and indicator details in Product view, page 9. The button,

indicator and connector numbers are indicated as (x).

Mechanical installation

The IP Audio Interface device can be either built-in a 19”‑frame using a 19”‑mounting frame or shelf (not included) or used stand alone.

Network (step 1)

Plug a standard (straight) network cable into the network port (13) of the IP Audio Interface and the other end into a switch of your network. Use a crossover network cable for a direct connection to your PC.

Audio Outputs (step 2)

Connect the Audio Output 1 (9) and/or 2 (8) to the amplifier or mixer input(s). Audio Output 2 also generates a pilot tone.

When powered up for the first time, the device will announce its IP address in English.

Connect an amplifier with loudspeaker or headphone to the device in order to hear the announcement. Keep a pen and paper ready to write down the IP address.

Power supply (step 3)

Connect the power supply to the power supply input connector (17). Optionally connect the back-up power supply to the power supply input connector (16).The device will start-up and the eight green Control I/O LEDs (3) go ON and the green and red status LEDs (2) flash alternating.

Note that the device will be powered from the voltage source with the highest voltage. Make sure that a battery back-up power supply has a lower voltage than the main power supply to avoid that the battery is drained during normal operation.

IP address (step 4)

The IP Audio Interface will search for a DHCP (Dynamic Host Configuration Protocol) server to get an IP (Internet Protocol) address. As soon as a valid and free IP address is found, it will be announced via the Audio Outputs 1 and 2 (9 and 8). Write down the IP address. Example:

192.168.0.12 (Voice: one nine two…).

The eight green Control I/O LEDs (3) and red status LED (2) go OFF and the green status LED

(2) switches ON.

The IP Audio Interface is now ready for configuration, but it is recommended to set a static IP

address, Connect to web browser, page 16.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

4.5.1

4.6

4.7

4.8

!

Installation | en

13

No DHCP server is found

If no DHCP server is found then the built‑in IPzator function will search the network for a free

IP address. This can take up to 5 minutes.

If the IP address is not announced, check:

– If the green LED on the network port used (13 or 14) is ON. When OFF, check your network cabling.

– The green status LED (2). When OFF, check the power supply cabling.

If the device still fails, revert to the factory default settings by pressing the reset button (1) between 5 and 10 seconds while it is powered and repeat the previous steps 1 up to 4.

Audio Inputs 1/2

Connect the Audio Inputs 1 and 2 (11 and 10).

Both balanced Audio Input 1 and 2 are independent from each other, but will always be routed together. Audio Input 1 is selectable between microphone and line level. If set to microphone sensitivity, it can also do microphone presence supervision.

Audio Input 2 is a line level input. It can detect a 20 kHz pilot‑tone which is generated by the connected audio source to supervise the connection.

Control Inputs

Connect the Control Inputs 1..8 (6 and 7) that are needed.

The Control Inputs 1..8 can be supervised (if configured). Two 10 kohm resistors have to be added to each Control Input to enable supervision. The resistors should be mounted close to the switch to make it possible for the device to supervise the cable between the switch and the input connector. The input detects a 10 kohm resistance if the switch is closed and a

20 kohm resistance if the switch is open. This way shorted and open circuits are detected as a fault situation. In case supervision is disabled for a Control Input, the resistors can be omitted and the switch can be wired directly to the input connector.

10 k

10 k

Figure 4.1: Supervised Control Input contacts

Caution!

Do not connect a voltage or current source to the Control Input contacts.

Control Outputs

Connect the Control Outputs 1..8 (4 and 5) that are needed as described in Product view, page

9.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

14

en | Connection options

5

5.1

Connection options

IP Audio Interface

This section illustrates how the IP Audio Interface can be used. A data stream can be sent and received by the IP Audio Interface. Different connection methods can be used depending on how the device is configured.

Unicast (point to point)

Unicast means: a single data stream to a single predefined receiver device (Partner) in a LAN or WAN. A typical partner IP address: 192.168.100.50

1

5.2

5.3

Figure 5.1: Unicast example (1=LAN/WAN)

Multiple Unicast

Multiple Unicast means multiple data streams to multiple receiver devices (Partners) in a LAN or WAN. Typical partner IP addresses: 192.168.100.50, 192.168.100.51, 192.168.100.52, etc.

1

X

Figure 5.2: Multiple Unicast example (1=LAN/WAN)

Broadcast

Broadcast means: a single data stream to all receiver devices (Partners) in a LAN. A typical partner IP address: 192.168.100.255 configured in the transmitter as Partner address. Then all partners with addresses starting with 192.168.100 receive this stream. Typically, routers in a

WAN do not support Broadcast mode.

1

2013.03 | V2.0 |

Figure 5.3: Broadcast example (1=LAN/WAN)

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

5.4

Connection options | en

15

Multicast

Multicast means: predefined receiver devices (Partners) each receive a single data stream in a

LAN or WAN. Typical partner IP addresses between: 224.0.0.1 to 239.255.255.255.

1

5.5

Figure 5.4: Multicasting example (1=LAN/WAN)

Re-broadcast

Re-broadcast means: a local device receives a data stream from a remote device and resends it to other devices (Partners) in a LAN or WAN.

3

2

1

2

Figure 5.5: Re-broadcasting (1=Internet, 2=Router, 3=LAN/WAN)

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

16

en | Configuration

6

6.1

!

IP Audio Interface

Configuration

The IP Audio Interface uses dynamic HTML web pages for configuration and status information monitoring. Configuration parameters are stored in the IP Audio Interface via the web browser.

Caution!

Your configuration parameters will be lost if the device is reset to factory default settings, see

Front view, page 9.

Connect to web browser

Open a web browser on a PC that is connected to the same network as the IP Audio Interface.

IP address.

Enter the announced IP address of the IP Audio Interface in the web browser address (URL)

box, see IP address (step 4), page 12.

The built‑in web server generates the STATUS page in the web browser by default. If not, repeat the installation process. The status screen is updated dynamically. The current implementation of this feature does not support all web browsers, for example, Google

Chrome.

2013.03 | V2.0 |

Figure 6.1: Status screen example

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2

Configuration | en

17

Configuration page

Click CONFIGURATION on top of the page. The Network menu on the left side is opened as a default. Here you can set the parameters for the:

Network (default page)

– Streaming

– Partner Table

– Outgoing Route Table

– Control

Audio Settings

Supervision

Control I/O mapping

– Control Input Mapping Table

– Control Output Mapping Table

Serial

SNMP

Security

Default Settings

Figure 6.2: Configuration (Network) screen example

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

18

en | Configuration

6.2.1

IP Audio Interface

Network

Unit name

Default: clear

Enter a name for the device. This name will be displayed in the title of the web browser application page.

IP address

Default: 0.0.0.0

You can enter the 4 values of the announced IP address to create a static IP address, or ask your system administrator for a valid IP address and enter it here. Or you can enter e.g.

192.168.0.12 for an internal LAN.

Subnet mask

Default: 0.0.0.0

You can also enter the 4 values of the desired static IP address, or enter 255.255.255.0 for a C class network (standard).

Default gateway

Default: 0.0.0.0 (no gateway)

You can also enter the 4 values of the desired Gateway IP address, or 192.168.0.1 for a

Gateway in a LAN.

Notice!

The Gateway has to be set only when connecting to other devices over a WAN through a router.

Type of Service / DSCP

Default value: 0Differentiated Service Code Point (DSCP) is used for audio streaming. This supersedes the IP4 Type of Service (ToS) value and uses the same byte. Valid values are 0 -

63. Check for DSCP services available in your network to set this value. The recommended

DSCP for voice traffic is the value 46 for Expedited Forwarding (EF).

Use SonicIP

Default: Yes

The device will announce its IP address over the Audio Outputs 1 and 2. If you select NO, then the device will not announce its IP address. This way start up is faster.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.2

Configuration | en

19

Streaming

Audio is transmitted using RTP over UDP. This requires no special configuration other than defining the UDP ports to be used for the communication.

Figure 6.3: Steaming screen (default UDP settings)

UDP Receiver Port

Default: 3030

You can also select 0 if the port is disabled or enter a different number for receiving an

RTP/UDP stream, between 0 (disabled) and 65535.

UDP Tx Source Port

Default: 0

This setting is only used with a custom software application. The default number 0 causes a random port to be used. Enter a specific source port number when sending an RTP/UDP stream. Enter a value between 0 and 65535.

Back channel

Default: ON

The Backward Signal Data (Back) channel may be turned ON or OFF. Set to ON if audio or control data should be send back to the transmitter device.

Back channel period

Default: 0 x 100 milliseconds

The Back channel period determines the rate at which control data is sent back to the audio transmitter within the range 100 ms to 4 s. The audio transmitter will then update the control output at a rate between 300 ms and 12 s.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

20

en | Configuration

6.2.3

IP Audio Interface

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Partner Table

The Partner Table is used to set the route parameters of up to 16 remote IP Audio Interface devices (Partners).

2013.03 | V2.0 |

Figure 6.4: Partner Table screen (default)

Ptnr (Partner)

The first row, Un-known, is to configure the behavior of the receiving device for unknown partners, i.e. partners that are not identified by their IP address. Then the table continues with

16 partner entries. A multicast group must always be known, so multicast addresses are always compared with entries in the table. Unknown partners cannot have a priority assigned and cannot be activated by a Control Input.

Pri (Priority)

In this column enter the Priority of the incoming audio streams from partners (0 - 255). The stream with the highest priority (highest number) is accepted. Existing streams with a lower priority are overridden, even if selected by a Control Input. Full duplex connections are considered to be permanent one-to-one connections for which Priority settings are ignored.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface Configuration | en

21

CI (Control Input)

Enter the number of the Control Input (1 - 8) of the receiver that will accept the audio stream from this partner. If the transmitting partner is streaming (always) to this receiver, this selection determines the accepted audio stream unless it is overruled by a higher priority stream. The default 0 means that a stream from this partner is not selected by a Control Input.

Full duplex connections are considered to be permanent one-to-one connections for which

Control Input selections are ignored.

Blk Inc (Block Incoming)

Default: unchecked

Check the check box to block the incoming data from the respective partner. Priority and

Control Input settings are ignored. The option to block individual partners is only available if the unknown partner is already blocked.

Spr Ply (Suppress Play)

Default: unchecked

Check the check box to suppress local playback of audio. This mode is used when rebroadcasting the incoming stream to other devices.

Re brd (Re-broadcast)

Default: Unchecked

Check the check box to allow for re-broadcasting to this IP address.

Sup vse (Supervise)

Check the checkbox to supervise the connection between the receiver and this partner. Even in case no audio stream is present the connection will be polled on a regular basis using an

ICMP message type 1 (ping). The replies will be counted and if 3 consecutive pings are not answered the partner device will be assumed to be off-line and the fault relay is activated.

Pings may also be lost due to network congestion but if the network connection is so bad that

3 consecutive replies are lost this condition should also be investigated. If all supervised devices come back on line then the fault relay will be cleared.

IP address

Default: 0.0.0.0

You can enter the IP address of the partner device here.

Port

Default: 3030

You can enter the port number of the partner device here, between 0 and 65535.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

22

en | Configuration

6.2.4

IP Audio Interface

Outgoing Route Table

The Outgoing Route Table is used to set the data stream for up to 16 remote IP Audio Interface devices (Partners).

2013.03 | V2.0 |

Figure 6.5: Outgoing Route Table screen (default)

Configure the streaming depending on the following events:

Stream Always

Default: unchecked

Check the check box to automatically stream to the selected partners (1..16) on start-up.

Instead of being always on, the stream can be activated on one or more Control Inputs or on detection of an incoming Pilot Tone. Please note that this activation is edge triggered and not level triggered, so streaming starts when one or more Control Inputs become active or when a

Pilot‑Tone is detected, but the streaming stops as soon as one of them is deactivated.

Stream on Control Input 1-8

Default: unchecked

Check the check box to stream to the selected partner (1..16) on activation of a Control Input

(1..8).

Stream on Pilot Tone

Default: uncheckedCheck the check box to stream to the selected partner (1..16) on detection of a 20 kHz Pilot Tone on Audio Input 2.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.5

Configuration | en

23

Control

The Control menu is used to set the port on which the command data stream is received.

Figure 6.6: Control screen (default)

UDP command port

Default: 12301

This sets the port through which the device will receive commands via UDP. To disable this port, set to 0.

Web server port

Default: 0

This sets the port through which the web server of the device can be reached. If set to 0, the default port 80 is used.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

24

en | Configuration

6.2.6

IP Audio Interface

Audio Settings

The Audio Settings are used to set all available audio input and output parameters.

2013.03 | V2.0 |

Figure 6.7: Audio Settings screen example

Audio inputs

Default: In 2, Line

For dual channel mode (MPEG encoding only), select input In 1 + In 2, Line.

To use a microphone, select In 1, Microphone. If a microphone input is selected, you can set the microphone type to Dynamic or Condenser. The phantom power supply for the microphone is automatically switched on when Condenser is selected.

Microphone supervision

Default: unchecked (disabled)

You can check the Supervision check box to enable microphone supervision.

Supervision of dynamic microphones is by measuring its impedance, supervision of a condenser microphone is by measuring its current consumption. When a supervised microphone gets disconnected or becomes defect a fault event is generated. This is visible on

the STATUS page, see Status page, page 39.

Microphone gain

Default: 0 dBYou can adjust the gain of the microphone input (0...22.5 dB) to adapt it to the microphone that is used.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface Configuration | en

25

Line gain

Default: 0 dB

You can adjust the gain of the line input (0...22.5 dB) to adapt it to the signal level of the source.

Loop Input to Output

Default: No

You can select Yes to route the Audio Input signal immediately to the local Audio Output. This is typically done for testing. Acoustical feedback (howling) may occur if a microphone and a loudspeaker are connected.

Pilot tone super. (Pilot Tone Supervision)

Default: No

When Pilot tone supervision is enabled, the presence of a 20 kHz pilot tone on audio input 2 is supervised and the result is shown on the status page. That status is also incorporated in the header of any audio stream transmitted. A receiving device can use this information to control its own pilot tone output.

By regenerating the pilot tone at the output of the receiving device, a pilot tone can be

“transferred” from the input of the transmitter to the output of the receiver, even though the audio channel itself does not have a 20 kHz audio bandwidth.

Audio Output

– Output level

Default: 0 dB

You can select the output signal level (0...-70 dB) here. Audio Output 2 may have a fixed level 20 kHz pilot‑tone signal.

– Output delay

Default: 64 ms

The default 64 ms is a practical minimum value. You can change this audio buffer size setting to adjust the delay before the received audio stream is played. A too low value may cause dropouts in the audio signal depending on the quality of the network connection. Higher delay values can be used with the purpose of acoustically aligning loudspeakers connected to different IP Audio Interfaces, e.g. in tunnel applications.

The maximum delay that can be selected depends on the chosen audio coding format and whether the audio stream is full duplex or not. A more efficient coding scheme, lower sample rate and half duplex mode allows for a longer delay. For G.711 (u-Law or A-Law) at 8 kHz sampling rate and half-duplex, the delay can be set up to approximately 8 s.

– Output level

Default: 0 dB

You can select the output signal level (0...-70 dB) here. Audio Output 2 may have a fixed level 20 kHz pilot‑tone signal.

– Output delay

Default: 64 ms

The default 64 ms is a practical minimum value. You can change this audio buffer size setting to adjust the delay before the received audio stream is played. A too low value may cause dropouts in the audio signal depending on the quality of the network connection. Higher delay values can be used with the purpose of acoustically aligning loudspeakers connected to different IP Audio Interfaces, e.g. in tunnel applications.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

26

en | Configuration IP Audio Interface

The maximum delay that can be selected depends on the chosen audio coding format and whether the audio stream is full duplex or not. A more efficient coding scheme, lower sample rate and half duplex mode allows for a longer delay. For G.711 (u-Law or A-Law) at 8 kHz sampling rate and half-duplex, the delay can be set up to approximately 8 s.

Audio format

– Encoding

Default: MPEG1-L2/22.05 kHz

You can select the audio encoding format here.

Options are MPEG1/2-layer 2 and -layer 3 (better known as MP3), G.711 (u-Law, A-Law) or uncompressed PCM at various sample rates.

MPEG1/2-layer 2 and -layer 3 allow for 2‑channel audio streaming; in that case select In1

+ In2, Line as audio input.

G.711 (u-Law and A-Law) and PCM are single channel modes; use either In2, Line or In1,

Microphone as input.

The bit rate is highest for uncompressed PCM and lowest for MPEG1/2 formats.

– MPEG Encoding Quality

Default: 7 (Highest)

You can select a quality level between 0 (lowest) and 7 (highest) for the encoding quality.

This setting is only valid for MPEG1/2-layer 2/3 (MP3). Higher quality settings use a higher bit rate and take up more network bandwidth. Also a higher sample rate for the same quality level increases the bit rate. If the required network bandwidth is not available (continuously) then audio dropouts may occur, especially for low delay settings.

The bit rate varies between approximately 30 kbps (quality level 0, sample rate 16 kHz) and 190 kbps (quality level 7, sample rate 48 kHz) for 2‑channels.

Audio Coding

Default: Full Duplex

Full Duplex is only available for the G.711 (u-Law, A-Law) and PCM formats. This means the device can simultaneously transmit an audio stream and receive an audio stream. In Half

Duplex mode the device only receives audio streams or transmits audio streams.

If MPEG1/2 is chosen, the device can only operate as audio stream receiver or as audio stream transmitter, but not simultaneously. This is Half Duplex (or Simplex) mode.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.7

Configuration | en

27

Supervision

The IP Audio Interface contains detectors for supervision of various functions of the device.

This way internal or external failures, disconnections or short circuits can be detected. Faults are reported via the Fault Relay and can be passed to partner devices.

Figure 6.8: Supervision screen (default)

Max. Internal temperature

Default: 80 °C

Enter the threshold for the Maximum Internal Temperature. If the set value is exceeded, a

Temperature Fault is generated and shown on the Status page, see Status page, page 39.

Min. Backup PWR voltage

Default: 0

Enter the value for the Minimum Backup Power Voltage.

If the voltage drops below the set value, a fault is generated and shown on the Status page,

see Status page, page 39.

Remote Supervision Period

Default: 0 seconds

Enter a value in the range 0 – 255 seconds. This is the time between consecutive pings to

supervised partners (checked as such in the Partner Table, see Partner Table, page 20).

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

28

en | Configuration IP Audio Interface

Supervision Sensor Mapping

Default: None

In the Supervision Sensor Mapping table you can select what actions should be taken if one of the faults occur that are in the table.

Options are: None, Local, Remote, Local and Remote.

None means that no action is taken when this fault occurs, except for indication on the

Status page, see Status page, page 39.

Local means that the fault is only indicated on the device itself.

Remote means that the fault is sent to and indicated on the partner devices.

Local and Remote means that the fault is indicated on both the device itself and the partner devices.

Faults that can be mapped are:

Control Inputs 1..8 fault. This fault can occur if the connections to one or more of the Control

Inputs are interrupted or shorted. Supervision should be enabled to detect this type fault, see

Control Input Mapping Table, page 29.

Temperature fault. This fault occurs if the set temperature is exceeded, see Supervision, page

27.

Backup Power fault. This fault occurs when the backup voltage drops below the set value, see

Supervision, page 27.

Main Power fault. This fault occurs when the main power supply becomes disconnected.

Condenser Microphone fault. This fault occurs when the connected condenser microphone becomes disconnected or fails. Supervision for the microphone input should be enabled, see

Audio Settings, page 24.

Dynamic Microphone fault. This fault occurs when the connected dynamic microphone becomes disconnected or fails. Supervision for the microphone input should be enabled, see

Audio Settings, page 24.

Pilot Tone fault. This fault occurs when no pilot tone is detected at Audio Input 2. Pilot Tone

supervision should be enabled, see Audio Settings, page 24.

Stream Loss fault. This fault occurs when the incoming data stream is lost, e.g. because the device became disconnected from the switch. A Stream Loss fault can only be Local, as there is no way to inform the partner devices, because of the disconnection.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.8

Control Input Mapping Table

Configuration | en

29

Figure 6.9: Control Input Mapping Table screen (default)

Defaults: No/None

In the Control Input Mapping Table for each of the Control Inputs the Supervision can be enabled and a response defined.

If Supervision is enabled for an input, then two 10 kohm resistors should be connected at the

far end, close to the switch or relay that is triggering this input, see Multiple Unicast, page 14.

If Supervision is not enabled, then the input can be connected directly to a switch or relay, without resistors. The operation of the Control Input is the same, but no unintentional open or short circuits can be detected anymore, as these are interpreted as normal trigger signals.

Each Control Input activation can be use to activate one of the eight Control Outputs of the connected partner devices. Please note that this activation is edge triggered and not level triggered, so multiple Control Inputs can activate the same Control Output, but the Control

Output is de-activated as soon as one of Control Inputs is deactivated.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

30

en | Configuration

6.2.9

Control Output Mapping Table

IP Audio Interface

2013.03 | V2.0 |

Figure 6.10: Control Output Mapping Table (default)

Defaults: Not Used/Normally Open

In the Control Output Mapping Table for each of the Control Outputs the activator (trigger) can be defined and the way the relay contact behaves.

Options for the Control Outputs are Not Used, Permanent, Remote, Remote & Audio Loss.

Permanent means that the Control Output contact is always Open or Closed, depending on the Contact Status.

Remote means that the Control Output contact is allowed to be activated by remote

actions of partner devices, see Control Input Mapping Table, page 29.

Remote & Audio Loss means that the Control Output contact is deactivated when the connection to one of the partner devices is lost.

In Contact Status you can set whether the Control Output is Normally open and will make

(close) on activation, or Normally Closed and will break (open) on activation.

The presence of a Pilot Tone on Audio Output 2 is considered to be special type of Control

Output. The Pilot Tone can be permanently or conditionally present or not.

Notice!

When both the main and backup power supplies are lost all contacts will be Open regardless of the settings. The Fault Relay contact will be Closed.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.10

Configuration | en

31

Serial (RS-232/RS-485)

This function is used for end-to-end serial data tunnelling with relatively low speed. This function is typically used for remote control, e.g. Pan/Tilt/Zoom control of a camera.

Figure 6.11: Serial (RS-232) screen default

Select either the RS‑232 or the RS‑485 port. Select the communication parameters as needed by the application and the connected devices. The serial parameters can be chosen independently at both ends of the communication. When tunneling, only the data is transmitted end to end, the RS‑232/RS‑485 control signals are only of local significance.

The serial input is automatically detected and the device supports both binary and formatted data streams.

All data received from the network in one IP packet will be transmitted in one block without framing, formatting or the addition of extra characters.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

32

en | Configuration

6.2.11

IP Audio Interface

SNMP

The IP Audio Interface contains an SNMP agent that can report the device status information to a managing system using a Trap protocol operation.

The PRS‑1AIP1 IP SNMP provides fault information via the following branches:

The commonly defined and shared “MIB II”: iso(1).org(3).dod(6).internet(1).mgmt(2).mib-2(1)

The audio left and right channel states defined under the Barix branch at: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).barix(17491).systems(2).

audio(1).states(1)

The Bosch specific branch (where the Bosch specific traps are assigned sequentially): iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).barix(17491).oem(10).

bosch(2)

The Bosch branch is further subdivided to define the supervised faults as data objects: prs1aip1(1).faults(1)

One trap is defined which shall deliver a 16 bit fault register value as an INTEGER and a fault reason as an enumerated INTEGER. This closely mimics the information found in the Config

View.

A formal definition of the required MIB is defined in BARIXOEMBOSCH.MIB which is provided as part of the release package on the CD.

2013.03 | V2.0 |

Figure 6.12: SNMP screen (default)

Trap Target IP Address

Default: 0.0.0.0

Enter the IP address of the SNMP trap destination.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.12

Configuration | en

33

Security

It is recommended to set a password to prevent unauthorized use of the CONFIGURATION,

UPDATE, STATUS and RESTART pages.

Figure 6.13: Security screen (default)

When a password is set for access to one or more of the available functions, the user will get a pop up window when accessing this function and has to enter the password into the password field of the pop up window. Additionally, a user name can be entered but this is not necessary.

Configuration/Update password

Default: not set

Enter up to 24 characters to protect the configuration and firmware updates pages of the device. Enter 25 characters to erase the current password. To log out click on the Logout button below the menu bar. On the Configuration and Update page only one user can log in at a time. Other login attempts will be refused.

Status Page View Password

Default: not set

Enter up to 24 characters to protect viewing the devices Status Page. Enter 25 characters to erase the current password. To log out click on the Logout button below the menu bar. On the

Status page several users can log in simultaneously.

Command/Reboot Password

Default: not set

Enter up to 24 characters to secure the Reboot page as well as the access to all control and command interfaces (WEB/CGI, Serial, TCP, and UDP). Enter 25 characters to erase the current password. To log out click on the Logout button below the menu bar. On the Reboot page only one user can log in at a time. Other login attempts will be refused.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

34

en | Configuration

6.2.13

IP Audio Interface

SNMP Community RWrite

Default: not protected

Select the SNMP access rights for the Read and Write Community. You can select between:

not protected, Configuration/Update, Status Page View, Command/Reboot and no write access.

SNMP Community Read

Default: not protected

Select the SNMP access rights for the Read Community. You can select between: not

protected, Configuration/Update, Status Page View, Command/Reboot and no access.

Note that the Community RWrite setting takes priority. This means that if the Community

RWrite is set to not protected, Community Read is ignored.

Submit / Cancel button

Submit saves the set values, restarts the device and returns back to the last screen. Cancel restores the last submitted values.

Default settings

2013.03 | V2.0 |

Figure 6.14: Default settings screen

Default settings

Clicking Back to factory defaults button to restore the factory defaults (except Network configuration). During the restart a countdown screen will appear. Then the successful loading of the factory defaults is confirmed.

Hard default settings

To revert all settings (including the Network configuration) to factory defaults, the Reset button (1) has to be pressed for about 5..10 seconds while the device is powered.

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

6.2.14

Configuration | en

35

Configuration view

When clicking CONFIG VIEW in the selection bar at the top of the page, all configuration settings are shown, including hardware and software version information of the device:

– Device Information

– Version Information

– System Status

– Audio Status

– I/O Status

– Network Configuration

– Streaming Configuration

– Control Configuration

– Audio Configuration

– Supervision

– Serial Configuration

– SNMP Configuration

– Security Configuration

Figure 6.15: Configuration View example screen

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

36

en | Configuration

6.2.15

IP Audio Interface

Update

Click UPDATE on top of the web browser page to check and/or update the device firmware and CONFIGURATION pages. The already saved configuration parameters will not change at update.

Figure 6.16: Update example screen

Update kit

Unpack the zip file that contains the update kit and save it to a local drive. The update kit can be found on the supplied CD and/or Bosch Security Systems restricted download web page.

Click UPDATE on top of the page. The update page appears which shows the current device

HW/SW version and a link. See “Update example” screen” screen.

Click Please click here to start the update. A countdown screen appears and then the next update page. See “Update file selection” screen.

2013.03 | V2.0 |

Figure 6.17: Update file selection

Operating Manual Bosch Security Systems B.V.

IP Audio Interface Configuration | en

37

Click Browse and select the file named compound.bin inside the folder update_rescue. See

“Compound.bin selection” screen. Open this file.

Figure 6.18: Compound.bin selection

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

38

en | Configuration IP Audio Interface

Click Upload. See “File upload” screen. This process can take a few minutes. When completed, click Reboot.

2013.03 | V2.0 |

Figure 6.19: File upload

After a successful upload, the following text ...\compound.bin successfully loaded appears. See

“Upload confirmation” screen.

Figure 6.20: Upload confirmation

Then click Update and Reboot. Finally click Click here to reload the main page. The STATUS page appears.

Advanced Update

The link Advanced Update should only be used when requested. It allows for partial updates when the target address is known. Within this manual the Advanced Update function is not supported.

See also

Update, page 36

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

7

7.1

Operation | en

39

Operation

Status page

The built‑in web server generates the STATUS page in the web browser by default. Note that the STATUS page refreshes about every three seconds (screen flash).

Click STATUS on top of the page when the page is not visible. Note that Some browsers, for example, Google Chrome, do not support automatic refreshes.

The STATUS page is divided into sections and provides real-time information about:

Control Inputs (1..8)

Control Outputs (1..8)

Audio

Codec

Power, Fault & Temperature

Last Caller

7.1.1

Figure 7.1: Status example screen

Control Inputs (1..8)

Visual indication of the Control Input status.

– Grey box: open contact

– Yellow box: open or shorted line

– Green box: closed contact

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

40

en | Operation

7.1.2

7.1.3

7.1.4

7.1.5

2013.03 | V2.0 |

IP Audio Interface

Control Outputs (1..8)

Visual indication of the Control Output status.

– Grey box: idle

– Green box: active

Audio

Visual indication of the Audio In/Out status.

Pilot tone (Audio Input 2 only).

– Grey box: no pilot tone configured

– Green box: pilot tone detected

– Yellow box: fault (pilot tone configured but not detected)

Microphone supervision (Audio Input 1 only)

Dyn.: status for dynamic microphone

Cond.: status for condenser microphone

– Grey box: supervision disabled

– Green box: microphone detected

– Yellow box: fault (microphone disconnected or shorted)

Audio In/Out 1 and 2

The audio peak level at Audio In 1/2 and Audio Out 1/2 in dB below maximum level.

Codec

Visual text indication of the data streaming status.

Audio Coding

– ENCODING: audio from an Audio Input is transmitted to the network

– DECODING: audio is received from the network and available on the Audio Output(s)

– FULL DUPLEX: audio from the Audio Input(s) is transmitted to the network and, at the same time, audio is received from the network and available on the Audio Output(s)

– DEVICE ERROR: indicates an error condition which is given in the CONFIG VIEW page

Application Mode

– IDLE: no data stream received or send

– TRANSMIT: data stream is sent to the network

– RECEIVE: data stream is received from the network

– TRANSMIT + RECEIVE: data stream is sent to the network and received from the network

– REBROADCAST: data stream is received from the network and retransmitted to a defined group of receivers (Partners)

Power, Fault & Temperature

Visual indication of the power, fault and temperature status.

Main PWR (values in Volt)

– Green box: main power supply (17) OK

– Yellow box: main power supply (17) fault

Back-up PWR (values in Volt):

– Green box: back-up power supply (16) OK

– Yellow box: back-up power supply (16) fault

Fault Relay

– Green box: no fault detected

– Yellow box: fault detected

Internal Temp. (°C)

– Green box: temperature is below the set limit

– Yellow box: temperature exceeds the set limit

Operating Manual Bosch Security Systems B.V.

IP Audio Interface

7.1.6

7.1.7

Operation | en

41

Last Caller

Shows the IP address of the last device that called.

Restart Page

The RESTART button on top of the web browser page is used to restarting the device after configuration or when the device is not working properly.

Figure 7.2: Restart screen

Restart the unit

Click RESTART on top of the web browser page.Then click Restart the unit to restart the device. During the restart a countdown screen is displayed.

After the successful restart is confirmed, leave the RESTART page by clicking any other menu item at the top of the page.

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

42

en | Maintenance

8

IP Audio Interface

Maintenance

The PRS‑1AIP1 is designed to operate over a long period of time. The unit contains no batteries or moving parts that could wear out and is sealed to avoid dust collecting within the unit. This means that there should be no need to open the unit.

– To clean the exterior of the unit, use a soft dry cloth. Do not spray any type of liquid directly onto the unit.

– Periodically check all cable connections for corrosion. Check the screw terminals to ensure connections are securely connected for optimal use of the unit.

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface Technical data | en

43

9

9.1

Technical data

Electrical

External power supply 1

External power supply 2

Power consumption

Microphone input (Audio input 1)

Sensitivity

Impedance

Frequency response

S/N

Supervision detection

Line Inputs (Audio input 1 and 2)

Sensitivity

Impedance

Frequency response

S/N

Pilot tone detection level

(Input 2 only)

Line outputs (Audio output 1 and 2)

Level

Pilot tone level (Output 2 only)

Audio formats

MPEG 1‑layer 3 (MP3)

MPEG 1‑layer 2

G.711

PCM

Control inputs

Connectors

Operation

Control / fault outputs

Bosch Security Systems B.V.

18 to 56 VDC

18 to 56 VDC

8 W max

-48.5 to -26 dBV

1360 ohm

100 Hz to 15 kHz

>60 dB

Electret: 0.4 – 5 mA

Dynamic: 120 – 1300 ohm

-16.5 to +6 dBV

22 kohm

20 Hz to 15 kHz

>70 dB

-30 dBV

Operating Manual

6 dBV max

-20 dBV (20 kHz)

32, 44.1 and 48 kHz sample rate

Encoding up to 192 kbps VBR

Decoding up to 320 kbps (Stereo)

16, 22.05 and 24 kHz sample rate uLaw, aLaw at 8, 24 or 32 kHz sample rate

16‑bit at 8, 24 or 32 kHz sample rate

8 x

Removable screw terminals

Closing contact (with supervision)

8 x / 1 x

2013.03 | V2.0 |

44

en | Technical data

9.2

9.3

Connectors

Operation

Rating

Ethernet 1 and 2

Connector

Standard

Speed

Flow

Protocol

RS 232 / RS 485

Connector RS 232

Connector RS 485

Pinout

Setting (default)

Mechanical

Dimensions (H x W x D)

Weight

Mounting

Color

Environmental conditions

Operating temperature

Start-up temperature

Storage temperature

Humidity

Air pressure

IP Audio Interface

Removable screw terminals

Make contact (SPST, voltage free)

24 V, 0.5 A

Dual RJ45, DTE-pinout

802.3i / 802.3u

10 / 100 Mbps, auto-negotiation

Full / half-duplex, auto-negotiation

TCP/IP, UDP, RTP, SIP, IGMP, DHCP, SNMP

9‑pin Sub‑D male, DTE‑pinout

Removable screw terminals

300 to 115.200 Baud

9600, 8, N, 1

216 x 38 x 125 mm( 8.5 x 1.5 x 4.92 in) (half

19” wide)

0.7 kg (1.5 lb)

Stand‑alone or in 19”‑rack with additional frame

Silver with Charcoal

-5 ºC to +50 ºC (+23 ºF to +122 ºF)

0 ºC to +50 ºC (+32 ºF to +122 ºF)

-20 ºC to +70 ºC (-4 ºF to +158 ºF)

15 to 90 %

600 to 1100 hPa

2013.03 | V2.0 | Operating Manual Bosch Security Systems B.V.

IP Audio Interface

9.4

EMC and Safety

Electromagnetic compatibility

Electrical safety

Approvals

Technical data | en

45

EN55011:2009 (Limit Class: B)

EN50130-4:1995 + A1:1998 + A2:2003

IEC60065 (CB‑scheme)

CE marking

EN54‑16 (0560 - CPD - 10219002/AA/04)

Bosch Security Systems B.V.

Operating Manual 2013.03 | V2.0 |

Bosch Security Systems B.V.

Torenallee 49

5617 BA Eindhoven

The Netherlands

www.boschsecurity.com

© Bosch Security Systems B.V., 2013

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project