FC PNXDCI 07-1027/AN
ACE MARKETING RCS VERSAILLES B 421 305 996 - These specifications are provided for information purposes and may be modified without warning – Non-contractual photos
– Design - Printed in the EU
3FC PNX DCI 07-1027-AN
27/03/07
17:31
Page 2
airwell.com
WALL MOUNTED RANGE
PHOENIX & FLORIDA DCI
3FC PNX DCI 07-1027-AN
27/03/07
17:31
Page 3
PHOENIX & FLORIDA DCI
Wall mounted DC INVERTER
Never has technology gone so far to provide optimum user comfort. The PHOENIX & FLORIDA DCI combine aesthetics,
refined lines and advanced technology.
An innovative design, with a rare degree of discretion and elegance mean that these wall mounted units can satisfy the
latest expectations in terms of living habitats. The latest DC INVERTER technology, in combination with the use of the
eco-friendly fluid R410A (that preserves the environment) make for optimum efficiency (class A energy label) and
exceptional performance levels. (Operates in hot mode down to -15 °C). Its flexibility, user friendliness, ability to retain
a constant temperature, broad operating range and extremely silent running make it an exceptional device. For perfect
air treatment quality, the PHOENIX & FLORIDA DCI are equipped as standard with an ioniser to provide a negative ion
balance in the air.
> The filters
M Standard filter
In addition to automatic air sweeping that adopts the best
blowing angle for the mode selected, this range has an exceptional
air treatment quality (ensured by 3 filtration levels) to provide
optimum comfort to the occupants.
Standard filters or pre-filters: eliminate the largest
particles (dust or other impurities).
They are regenerative (wash with soapy water),
and an indicator light shows the cleaning times.
Activated carbon filter: specially designed to neutralise
odour-bearing particles (tobacco, kitchen smells, animal smells,
etc.), this photo-catalytic type filter needs to be placed in the light
every 6 months to restore its optimum efficiency.
Active electrostatic filter (ESF): Electrically charged particles are
attracted by a series of polarised plates that trap and collect dust,
pollen, mites, bacteria, tobacco smoke. Its full efficiency is restored
simply by washing in water.
M Activated carbon filter
The PHOENIX & FLORIDA DCI
wall-mounted split unit range is
available with the ecologically
friendly fluid R410A.
This provides high energy efficiency, while
preserving the ozone layer, and is easily
recyclable.
Its high density and high energy efficiency
make for high performance coefficients,
thereby providing significant energy savings.
M Active electrostatic filter
> Ioniser
The air we breathe is electrically charged, positively and negatively. In closed and urban
environments, the concentration of negative ions in the atmosphere is lower.
The AIRWELL ioniser restores the negative ion balance in our environment, to provide an
exceptional level of habitat comfort.
Average negative ions in our environment (quantity per cubic centimetre):
Seaside ______________________________________________ 10 000 cc
Mountains __________________________________________ 5 000 cc
City_____________________________________________________ 1 000 cc
City centre office (average) ______________
50 cc
The AIRWELL ion generator installed on the device generates a quantity of ions of between
30,000 and 50,000 per cubic centimetre.
> The Inverter technology comprises:
A DC INVERTER type
variable power compressor
that provides better
regulation and
temperature control.
30% energy saving.
ultra silent operation.
Air-conditioner
Energy
Manufacturer
Outdoor unit
Indoor unit
GC 9DCI
ST PNX 9 DCI
More efficient
A
A
B
C
D
E
F
G
Less efficient
Annual energy consumption
kWh in cooling mode
(Actual consumption will depend
on how the appliance is used
and climate)
Cooling output
kW
Energy efficiency ratio
2,50
4,20
Ful load (the higher the better)
Type
Cooling only
Cooling + Heating
Air cooled
Water cooled
> Airconet control system
By using a communication gateway for connecting several PNX & FLO DCI
indoor units, and with a simple Internet navigator, it is possible to achieve
centralised and remote management of all your indoor units, room by room
and floor by floor …).
In addition to improved occupant comfort (by programming unit start-up prior
to the occupant's arrival) and reduced energy bills via closer consumption control as well
as simplified management, the AircoNet system requires no special software installation
and enables you to be kept informed of any system incident in real time by e-mail or SMS.
Heat output
kW
Heating performance
A: higher
G: lower
Noise
(dB(A) re 1 pW)
Further information is contained
in product brochures
Norm EN 814
Air-conditioner
Energy Label Directive 2002/31/EC
26
3FC PNX DCI 07-1027-AN
27/03/07
17:31
Page 4
INDOOR UNITS
PHOENIX & FLORIDA DCI
DCI
OUTDOOR UNITS
The heat-stable polyester material structure provides a reduction
in the noise level, weight and a prolonged service life.
The anticorrosion treatment with a High density powder paint
coating ensures high resistance whatever the operating
conditions.
Indoor units PNX 9/12 DCI
FLO 18/21/24 DCI
GCNG 12/18 DCI
GC 24/30 DCI
FLO 30 DCI
COMPRESSOR
A variable power DC INVERTER rotary type,
this compressor provides high efficiency and
increased acoustic isolation.
EVAPORATOR
The double bend evaporator provides a greater
exchange surface area, which increases its
effectiveness and efficiency, while also reducing
the size.
CONDENSER
“Bluefin” hydrophilic treatment promotes the
flow of condensates, while also providing
corrosion protection to maintain performance
levels and prolonging the service life.
LCD SCREEN
VENTILATOR MOTOR
Simple and user-friendly, this
electro-luminescent display lets you view the following
simultaneously: the various modes, the temperature setting,
the ventilation speed.
A variable power DC INVERTER type,
this high efficiency motor provides silent
operation.
TURBINE
PROPELLER
The aerodynamically designed
tangential turbine, with a diameter
greater than the conventional model, enhances the exchange process
and reduces the noise level.
With 3 aerodynamic blades, the propeller offers
better balance, enhances the exchange process
and makes silent operation possible.
Infrared remote control RC4
With its very compact size and carefully
designed ergonomics, the Airwell
infrared remote control offers excellent
user comfort. It allows the user
to programme numerous sophisticated
functions such as: selection
of 3 different fan/ventilation speeds,
night time slow running, timer settings,
dehumidification, energy savings
function, “I feel” function…
On/Off
By simply pressing a single key, the
desired temperature can be very
accurately obtained and controlled.
Sleep function
3 fixed FAN speeds
+ one automatic speed
“I feel” sensor
“I feel” Function
Temperature control
Timer selection
Setting of
Start-Stop times
Operating
mode selector
Room temperature
control
Auto sweep
Child safety device
Confirmation
of programmed setting
Cancellation
of timer parameters
3FC PNX DCI 07-1027-AN
27/03/07
17:31
Page 1
a
PNX & FLO DCI
P
H
EAT PUM
Cooling capacity
Power Input
EER/ Energy Label
Operating limits outdoor temperature
kW
kW
Heating Capacity
Heating Capacity at -10°C out.
Power Input
COP / Label Energy
Operating limits outdoor temperature
kW
kW
kW
Indoor units
Airflow (LS/HS)
Acoustic pressure to 1m (LS/HS)
Dehumidification
Weight
Dimensions (WxDxH)
Outdoor units
Air flow
Acoustic pressure to 1m (LS/HS)
Compressor type
Weight
Dimensions (WxDxH)
2,5 (1,4-3,6)
0,59
4,2 / A
3,5 (1,4-4,3)
0,99
3,5 / A
5 (1,5-6)
6 (1,5-6,7)
1,46
1,99
3,4 / A
3,01 / B
-10°/ 46° Dry Bulb
6,8 (1,5-7,5)
2,25
3,0 / B
7,8 (1,5-8,8)
2,59
3,0 / B
3,4 (1,5-5)
2,0
0,81
4,2 / A
4,3 (1,5-5,8)
2,6
1,12
3,8 / A
6 (1,5-7,6)
6,5 (1,8-7,9)
2,3
1,66
1,90
3,6 / A
3,42 / B
-15°/ 24° Dry Bulb
7,05 (1,5-8,8)
2,19
3,21 / C
8,5 (1,5-9,5)
2,65
3,2 / C
ST PNX 9 DCI
350/460/570
26/39
1
10,5
810x190x285
ST PNX 12 DCI
370/480/580
26/39
1,5
11,5
810x190x285
ST FLO 18 DCI
620/760/850
34/43
2
15
1060x210x295
ST FLO 21 DCI
620/760/900
34/45
2
15
1060x210x295
ST FLO 24 DCI
700/850/1000
38/47
2,5
15
1060x210x295
ST FLO 30 DCI
950/1100/1350
44/51
3
18,5
1200x236x340
kg
mm
GC 9 DCI
1780
51
Rotary DC Inverter
38
795x290x610
GC 12 DCI
1780
52
Rotary DC Inverter
38
795x290x610
GC 18 DCI
2160
53
Scroll DC Inverter
39
795x290x610
GC 21 DCI
2860
55
Scroll DC Inverter
46
846x302x690
GC 24 DCI
3600
56
Twin Rotary DC Inv.
64,5
950x412x835
GC 30 DCI
3600
56
Twin Rotary DC Inv.
66
950x412x835
mm2
A
mm2
Indoor
3x1,5
16
4x1,5
Indoor
3x1,5
16
4x1,5
Indoor
3x2,5
20
4x2,5
Indoor
3x2,5
20
4x2,5
Outdoor
3x2,5
20
4x2,5
Outdoor
3x2,5
20
4x2,5
20
10
3/8”
1/4”
20
10
3/8”
1/4”
30
10
1/2”
1/4”
30
10
1/2”
1/4”
30
15
5/8”
3/8”
30
15
5/8”
3/8”
°C
°C
m3/h
dB(A)
l/h
kg
mm
m3/h
dB(A)
Linking specifications between units
Power supply
Power supply side
Power cable section
Fuse rating am
Electrical connections Ind./Out.
Linking pipes
Max. lenght
Max. height
Suction pipe diameter
Liquid pipe diameter
m
m
Inches
Inches
(1) Nominal heating capacity: International conditions 20°C/12°C wet bulb – Outside air temperature: 7°C/6°C wet bulb. (2) Nominal cooling capacity: International conditions
(NF EN 255.2 / 814.2 standards) - 27°C/19°C wet bulb – Outside air temperature: 35°C/24°C wet bulb. (3) Global acoustic pressure in dB(A) (1 m) at nominal conditions:
outdoor unit in an open area against a reflective background – indoor unit : installation in an average sized room, (PV-0.5s reverberation)
Your approved
ACE MARKETING SAS - 1 bis, av. du 8 mai 1945 - Saint-Quentin-en-Yvelines
F - 78284 Guyancourt Cedex
Fax : +33 (0) 1 39 44 65 17 - Tél. : +33 (0) 1 39 44 78 00 - e-mail : contact@airwell.com
w w w. a i r we l l . c o m
distributor
ACE MARKETING RCS VERSAILLES B 421 305 996 - These specifications are provided for information purposes and may be modified without warning – Non-contractual photos
PNX 9 DC INV PNX 12 DC INV FLO 18 DC INV FLO 21 DC INV FLO 24 DC INV FLO 30 DC INV
FC PNXDCI 07-1027/AN
PNX & FLO DC INVERTER Series
– Design - Printed in the EU
Wall mounted DC INVERTER
Download PDF

advertising