PRODUCT NAME: BC-125/ 150- EXPLOSION-PROOF BEACON & LIGHT
DOC NO.: EX-TECH SAS-12-BC-TM REV02
EXPLOSIONPROOF BEACON & LIGHT
II 2GD
EPL Gb, Db
Exd IIC T4/T5/T6 Gb, IP66/67
Ex tb IIIC Txxx
EX-TECH SAS
BC125/ 150 EXPLOSIONPROOF BEACON & LIGHT
TECHNICAL MANUAL
Marking details;
Please note that care has been taken to ensure the accuracy of our technical manual. We do not, however, accept
responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make
alterations in line with technical advances and industry standards.
EX-TECH SAS-12-BC-TM REV02
1.0 INTRODUCTION
3.0 TYPE APPROVAL STANDARD
BC series Explosion-proof Beacon & Light is designed for
use
in
Oil
Petrochemical,
&
Gas,
Offshore
Refinery
and
Platform,
Marine
Chemical,
Industries
etc.
The BC series products have been approved according
the following standards:
Enclosure material is Stainless Steel (BC 125) or GRP (BC
IEC/EN 60079 General Requirements
150). Different flash or rotary rate can be adjusted from
IEC/ EN 60079-1 Flameproof Enclosure‘d’
unique design. Three working statuses-flash type, rotary
IEC/ EN 60079-31 Dust atmosphere “t”
type and steady type are available (LED).
There are 2 types of beacon (Xenon type and LED type)
4.0 ZONES, GASGROUP, CATEGORY AND
available for the customer.
TEMPERATURE CLASSIFICATION
2.0 EXPLOSION-PROOF LABELING
The BC series products have been certified Ex d IIC
T4~T6. This means that the units can be installed in
All products have a rating label, which carries the following
locations with the following conditions:
important information:
Area Classification:
Product order no.:
e.g. BC125RX05DCNNNAR
(Refer to the datasheet for product order selection)
Input voltage: up to 48V DC or 100-254V AC
Zone 1: Explosive gas air mixture likely to occur in normal
operation.
Zone 2: Explosive gas air mixture not likely to occur, and if
it does, it will only exist for a short time.
Gas Groupings: Group IIA Propane Group
Code:
IIB Ethylene Group
Exd IIC Txx Gb
IIC Hydrogen and Acetylene
Equipment Category: ATEX, 2GD
ATEX Marking:
EPL; Gb/ Db
Gas Group and Category: II 2G
Temperature Range: See label, ref page 1
CE Mark:
5.0 INSTALLATION
Warning: DO NOT OPEN WHEN AN EXPLOSIVE GAS
General Requirement
ATMOSPHERE IS PRESENT
Selection, Installation, Maintenance and repair of electrical
Finish product serial no. (Include date of construction)
apparatus for use in potentially explosive atmosphere
Note; exact information is given on the actual label, ref
should be done in according to IEC/ EN 6079-14/ -17/ -19 .
also example on page 1.
Product installation must be carried out in accordance with
any local codes that may apply and should only be carried
out by a competent electrical engineer.
Location
The location of the unit should be made with due regard to
the area over which the beacon warning signal must be
EX-TECH SAS-12-BC-TM REV02
visible. The unit should only be fixed to services that can
carry the weight of the unit.
Mounting
The product should be mounted on a vertical surface using
4 fixing holes in the base. The fixing holes are designed to
fit M5 Allen Screw only. Use of stainless steel fastener is
recommended by EX-TECH SAS. The Beacon can be
operated in any attitude. If you need mounting plate,
please contact EX-TECH SAS for the installation drawing
of the mounting plate.
6.0 WIRING
General Requirement
EX-TECH SAS recommends that all cables and cores
should be fully identified (suggest using cable from 2.0 to
2.5 mm²). Ensure that all nuts, bolts and screws are
secured. Ensure that only the right and certified cable
glands are used and earthed correctly. Ensure that only
the right and certified stopping plugs are used to blank off
unused gland entry points. In order to maintain the IP
rating of the product, we recommend SS316L for this
application.
Cable Connection
The cable connection is connected with the 3-hole terminal
BC 125
blocks marked POWER IN located in the flameproof
enclosure (See Fig 2).Cable connection should be carried
out in accordance with relevant technical requirement.
BC 150
4 lid screws for BC 125
6 lid screws for BC 150
Remove Top Cover (Beacon Component)
Unscrew the 4/6 M5 retained hex socket head screws.
This will release the cover from the base and allow the
EX-TECH SAS-12-BC125-TM REV02
cover to hang on the retaining wire strap. Before replacing
7.0 STATUS CHOSEN AND FLASHING FREQUENCY
the cover, check that the flameproof joints are clean and
ADJUSTMENT
not damaged, the gasket is still retained in its groove.
CAUTION: Before removing the cover, ensure the power
to beacon is isolated. Remove the four pieces of M5
socket screws to open the cover. Twist the cover gently
LED Beacon
The LED beacon provides flashing and rotary status to be
selected
clockwise and anti-clockwise, whilst pulling away from the
Use DIP Switch with 3 binary codes on the LED Beacon
base, until it comes off. Replace the cover in similar way,
PCB to select flashing or rotary status (including steady
but operate in reverse manner as above.
status), the 3 binary code is for high and low frequency
rd
chosen.
Power Supply
Up to 48 DC or 100-240V AC
LED Status Selection Switch
st
1 &2
nd
DIP Switch: ON=1, OFF=0;
rd
3 DIP Switch: HIGH= 1, LOW= 0
S1/S2: ON= Connect with 0/COM, OFF= Disconnect with
DIP Switch
0/COM
S1/S2
DIP
Switch
S1=OFF
S2=OFF
S1=ON
S2=OFF
S1=OFF
S2=ON
S1=ON
S2=ON
Alarm
Stage 4
1st
DIP
2nd
DIP
3rd
DIP
Alarm
Stage 1
Alarm
Stage 2
Alarm
Stage 3
0
0
0(1)
OFF
Flash
60 (75)
times/min.
Flash
75 (90)
times/min.
Steady
1
0
0(1)
OFF
Steady
0
1
0(1)
OFF
1
1
0(1)
OFF
L N S0 S1 S2
LED PCB
DIP Switch
Rotary
Rotary
60 (75)
times/min
75 (90)
times/min
Triple
Flash
60 (75)
times/min.
Triple
Flash
75 (90)
times/min.
Triple
Flash
100(120)
times/min.
Flash
&Rotary
Flash
&Rotary
Flash
&Rotary
60 (75)
times/min
75 (90)
times/min
100(120)
times/min
Xenon Beacon
Xenon PCB
The Xenon Beacon provides flashing status Use DIP
Switch with 2 binary codes on the Xenon Beacon PCB
(see Fig 3) for frequency adjustment.
PCB Wiring Terminals (See Fig 3)
Apply power supply to up to 48V DC 100-250V ‘L’ & ‘N’
according to the information on the label
3
EX-TECH SAS-12-BC-TM REV02
Xenon Beacon Flashing Frequency Adjustment
10.0 MAINTENANCE
DIP Switch: ON=1, OFF=0
During working life of the product, little or no maintenance
S1/S2: ON= Connect to COM, OFF= Disconnect to COM
is required. Stainless Steel and GRP is resistant to most of
the acids, alkalis and chemicals.
S1/S2
DIP
Switch
1
2
S1 = OFF
S1 = ON
S1 = OFF
S1 = ON
S2 = OFF
S2 = OFF
S2 = ON
S2 = ON
Alarm
Alarm
Alarm
Alarm
Stage 1
Stage 2
Stage 3
Stage 4
90
times/min (1)
120
times/min (1)
1
1
OFF
60
times/min (1)
0
1
OFF
60
times/min (2)
60
times/min (3)
60
times/min (4)
1
0
OFF
60
times/min (3)
60
times/min (4)
60
times/min (5)
OFF
60
times/min (4)
60
times/min (5)
60
times/min (6)
If abnormal or unusual environmental conditions occur due
to accident etc., visual inspection is recommended.
To avoid electrostatic charge build-up, only exterior of the
product can be cleaned with a damp cloth.
If spare parts are required, these can be supplied by EXTECH SAS Company.
If any failure occurs but not caused by human factor, the
product can be returned to EX-TECH SAS for free repair
0
0
All the value in () are the number of flash by time
8.0 CABLE GLAND
or replacement during warranty period.
11.0 CONDITIONS FOR SAFETY USE
i.
This apparatus is suitable to be used only in
ambient temperature as stated below at the label
The BC series product has four cable gland entries. Only
cable glands approved for Ex ‘d’ applications can be used,
ii.
surface finishing are not permitted by the third
which must be suitable for the type of cable being used
party.
and also meet the requirements of the Ex ‘d’ flameproof
installation standard IEC/ EN 60079-14..
SAFETY WARNING: If the BC is used at high ambient
temperatures, i.e. over +40ºC, then the cable entry
temperature may exceed +70ºC and therefore suitable
Other than product manufacturer, painting and
iii.
When used in dusty atmosphere, flameproof cable
entry devices or stopping plugs have to be selected
and installed carefully in order to maintain the IP
rating (IP66/67) of the product.
heat resisting cable glands must be used, with a rated
service temperature of at least 95ºC.
If a high IP (Ingress Protection) rating is required, a
suitable sealing washer must be fitted under the cable
gland. When only one cable entry is used, the other one
EX-TECH SAS.
must be closed with an Ex ‘d’ flameproof blanking plug,
ZA Les Montagnes – 355 rue de la Génoise –
which must be suitably approved for the installation
16430 CHAMPNIERS (France)
requirements.
Tel: +33 5 45 61 81 68
9.0 END OF LINE MONITORING
Fax: +33 5 45 23 29 46
An end of line monitoring diode or an end of line
monitoring resistor can be connected across the 24V+ and
Website: www.ex-tech.no
0 terminals. If an end of line monitoring resistor is used, it
E-mail:[email protected]
must have a maximum resistance value of 3k ohms and a
minimum wattage of 0.5 Watts; or a minimum resistance
value of 1.2k ohms and a maximum wattage of 2 Watts.