PRODUCT NAME: SL- EXPLOSION-PROOF STATUS LIGHT/LAMP
DOC NO.: EX-TECH SAS-12-SL-TM REV01
EXPLOSIONPROOF STATUS LIGHT/LAMP
II 2GD
EPL Gb, Db
Exd IIC T4/T5/T6 Gb, IP66/67
Ex tb IIIC Txxx
EX-TECH SAS
SL- EXPLOSIONPROOF STATUS LIGHT/LAMP
TECHNICAL MANUAL
Marking details;
Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however,
accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make
alterations in line with technical advances and industry standards.
EX-TECH SAS-12-SL-TM REV01
1.0 INTRODUCTION
SL series Explosion-proof status light/ lamp is designed for
3.0 TYPE APPROVAL STANDARD
use in Oil & Gas, Offshore Platform, Chemical,
The SL series products have been approved according the
Petrochemical, Refinery and Marine Industries etc.
following standards:
Enclosure material is Stainless Steel (BC 125) or GRP (BC
150). Different flash or rotary rate can be adjusted from
unique design. Three working statuses-flash type, rotary
type and steady type are available (LED).
IEC/EN 60079 General Requirements
IEC/ EN 60079-1 Flameproof Enclosure ‘d’
IEC/ EN 60079-31 Dust atmosphere “t”
There are 2 types of beacon (Xenon type and LED type)
available for the customer.
4.0 ZONES, GASGROUP, CATEGORY AND
TEMPERATURE CLASSIFICATION
2.0 EXPLOSION-PROOF LABELING
The SL series products have been certified Ex d IIC T4~T6.
All products have a rating label, which carries the following
This means that the units can be installed in locations with
important information:
the following conditions:
Product order no.:
e.g. SL150C40RXAXBX05GL05DCNNNAR
5.0 INSTALLATION
General Requirement
(Refer to the datasheet for product order
selection) Input voltage: up to 48V DC or 100-254V AC
General Requirement
Selection, Installation, Maintenance and repair of electrical
Code:
apparatus for use in potentially explosive atmosphere should
Exd IIC Txx Gb
be done in according to IEC/ EN 6079-14/ -17/ -19 . Product
installation must be carried out in accordance with any local
Ex tb IIIC Txxx
codes that may apply and should only be carried out by a
competent electrical engineer.
ATEX Marking:
Location
Gas Group and Category: II 2G
CE Mark:
The location of the unit should be made with due regard to
the area over which the warning signal must be visible
and the manual call point/junction box can be easily
Warning:
DO NOT OPEN WHEN AN
EXPLOSIVE GAS ATMOSPHERE IS PRESENT
Finish product serial no. (Include date of construction)
Note; exact information is given on the actual label, ref
also example on page 1.
Warning: DO NOT OPEN WHEN AN EXPLOSIVE
GAS ATMOSPHERE IS PRESENT
operated. The unit should only be fixed to services that
can carry the weight of the unit.
EX-TECH SAS-12-SL-TM REV01
.
Mounting
The SL serious of products
should be mounted on a
vertical surface via a stainless steel mounting plate (See
Fig 1A/1B/1C/1D/1E). The fixing holes on the mounting
plate are designed to fit M8 Allen Screw only. The
diameter is 9mm. Use of stainless steel fastener is
recommended by EX-TECH SAS.
Fig 1C
Fig 1A
Fig 1B
Fig 1D
The figures are related to SL 150
2
EX-TECH SAS-12-SL-TM REV01
Fig 1E
6.0 WIRING
General Requirement
cover to hang on the retaining wire strap.
EX-TECH SAS recommends that all cables and cores
Before replacing the lid, check that the flameproof joints
should be fully identified (suggest using cable from 2.0 to
are clean and not damaged, and the gasket is retained in
2.5 mm²). Ensure that all nuts, bolts and screws are
the groove
secured. Ensure that only the right and certified cable
glands are used and earthed correctly. Ensure that only
the right and certified stopping plugs are used to blank
off unused gland entry points. In order to maintain the IP
rating of the product, we recommend SS316L for this
application.
Cable Connection
The cable connection is connected with the terminal
blocks assembly located in the flameproof enclosure of the
Fig 2
CAUTION: Before removing the cover, ensure the power
to the product is isolated. Remove the four pieces of M5
socket screws to open the cover. Twist the cover gently
clockwise and anti-clockwise, whilst pulling away from the
bottom unit which can be Beacon Component (See Fig 2)
base, until it comes off. Replace the cover in similar way,
or Junction Box/Push Button. Cable connection should
but operate in reverse manner as above.
be carried out in accordance with relevant technical
Power Supply
requirement.
Input
Remove End Cover (Beacon Component)
Unscrew socket head screws (4 for SL 125 and 5 for SL
150) of the bottom Beacon Component (See Fig 2).
This will release the cover from the base and allow
voltage:
up
to
48V
DC
or
100-254V
AC
EX-TECH SAS-12-SL-TM REV01
LED Status Selection Switch
DIP Switch
st
1 &2
nd
DIP Switch: ON=1, OFF=0;
rd
3 DIP Switch: HIGH= 1, LOW= 0
S1/S2: ON= Connect with 0/COM, OFF= Disconnect with
0/COM
S1/S2
DIP
Switch
L N S0S1S2
S1=OFF
S2=OFF
S1=ON
S2=OFF
S1=OFF
S2=ON
S1=ON
S2=ON
Alarm
Stage 4
1st
DIP
2nd
DIP
3rd
DIP
Alarm
Stage 1
Alarm
Stage 2
Alarm
Stage 3
0
0
0(1)
OFF
Flash
60 (75)
times/min.
Flash
75 (90)
times/min.
Steady
1
0
0(1)
OFF
Steady
LED PCB
Rotary
Rotary
60 (75)
times/min
75 (90)
times/min
Triple
Flash
60 (75)
times/min.
Triple
Flash
75 (90)
times/min.
Triple
Flash
100(120)
times/min.
Flash
&Rotary
Flash
&Rotary
Flash
&Rotary
60 (75)
times/min
75 (90)
times/min
100(120)
times/min
DIP Switch
0
1
1
1
0(1)
0(1)
OFF
OFF
Xenon Beacon
The Xenon Beacon provides flashing status
L N S0S1S2
Use DIP Switch with 2 binary codes on the Xenon
Beacon PCB (see Fig 3) for frequency adjustment.
Xenon PCB
Xenon Beacon Flashing Frequency Adjustment
Fig 3
DIP Switch: ON=1, OFF=0
PCB Wiring Terminals (See Fig 3)
S1/S2: ON= Connect to COM, OFF= Disconnect to COM
Apply power supply to 12V/24V/36V/48V DC 100-250V
‘L’ & ‘N’ (See Fig 3)
S1/S2
DIP
Switch
7.0 STATUS CHOSEN AND FLASHING FREQUENCY
1
ADJUSTMENT
LED Beacon
2
S1 = OFF
S1 = ON
S1 = OFF
S1 = ON
S2 = OFF
S2 = OFF
S2 = ON
S2 = ON
Alarm
Alarm
Alarm
Alarm
Stage 1
Stage 2
Stage 3
Stage 4
1
1
OFF
60
times/min (1)
90
times/min (1)
120
times/min (1)
0
1
OFF
60
times/min (2)
60
times/min (3)
60
times/min (4)
1
0
OFF
60
times/min (3)
60
times/min (4)
60
times/min (5)
0
0
OFF
60
times/min (4)
60
times/min (5)
60
times/min (6)
The LED beacon provides flashing and rotary status to be
selected
Use DIP Switch with 3 binary codes on the LED Beacon
PCB to select flashing or rotary status (including steady
status), the 3
rd
binary code is for high and low frequency
chosen.
All the value in () are the number of flash by time
4
EX-TECH SAS-12-SL-TM REV01
alkalis and chemicals.
8.0 CABLE GLAND
The SL series o f product has cable gland entries. Only
If abnormal or unusual environmental conditions occur due
cable glands approved for Ex ‘d’ applications can be used,
to accident etc., visual inspection is recommended.
which must be suitable for the type of cable being used
To avoid electrostatic charge build-up, only exterior of the
and also meet the requirements of the Ex ‘d’ flameproof
product can be cleaned with a damp cloth.
installation standard IEC/EN 60079-14.
If spare parts are required, these can be supplied by EX-
SAFETY WARNING: If the SL products is used at high
ambient temperatures, i.e. over +40ºC, then the cable
entry temperature may exceed +70ºC and therefore
suitable heat resisting cable glands must be used, with
TECH SAS Company.
If any failure occurs but not caused by human factor, the
product can be returned to EX-TECH SAS for free repair
or replacement during warranty period.
a rated service temperature of at least 95ºC.
If a high IP (Ingress Protection) rating is required, a
suitable sealing washer must be fitted under the cable
gland.
11
CONDITIONS FOR SAFETY USE
This apparatus is suitable to be used only in
When only one cable entry is used, the other one must be
ambient temperature as stated below:
closed with an Ex ‘d’ flameproof blanking plug, which must
be suitably approved for the installation requirements.
Type
Ambient Temp.
SL-150
-40 to +70 ºC
9.0 END OF LINE MONITORING
An end of line monitoring diode or an end of line
monitoring resistor can be connected across the 24V+ and
0 terminals. If an end of line monitoring resistor is used, it
must have a maximum resistance value of 3k ohms and a
i.
surface finishing are not permitted by the third party.
minimum wattage of 0.5 Watts; or a minimum resistance
value of 1.2k ohms and a maximum wattage of 2 Watts.
is required. Stainless Steel is resistant to most of the acids,
This apparatus is suitable to be used only
in ambient temperature as stated below at
the label
Other than product manufacturer, painting
and surface finishing are not permitted by
the third party.
iii.
When
used
When used in dusty atmosphere, flameproof cable
and installed carefully in order to maintain the IP
During working life of the product, little or no maintenance
ii.
ii.
entry devices or stopping plugs have to be selected
10.0 MAINTENANCE
i.
Other than product manufacturer, painting and
in
dusty
atmosphere,
flameproof cable entry devices or stopping
plugs have to be selected and installed
carefully in order to maintain the IP rating
(IP66/67) of the product.
rating (IP66/67) of the product.
EX-TECH SAS
ZA Les Montagnes – 355 rue de la Génoise
16430 CHAMPNIERS
Tel: +33 5 45 61 81 68
Fax: +33 5 45 23 29 46
Website: www.ex-tech.no
E-mail : [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement