Owner's manual | Earthwise Technologies CZ?1000F Owner`s manual

Add to My manuals
12 Pages

advertisement

Owner's manual | Earthwise Technologies CZ?1000F Owner`s manual | Manualzz

CZ Infrared Heaters

Green Technology for a Modern World

 North American Distribution and Sales 

EarthWise

Technologies, Inc 

18324 Cook Road, Suite 6 

Yelm, Washington 98597 

Customer/Warranty Service: 

(866) 446‐2864 

bearthwise.com 

Earthwise

Technologies, Inc

CZ Infrared ™ by EarthWise. Feel the Difference.

CZ Infrared

Owner’s Manual

Therapeutic infrared heating systems for a green,  healthy environment 

Flush Mounting Series 

Models CZ‐1000F  /  Model CZ‐500F 

Save these instructions

Includes: 

   Application Guidelines 

   Installation Guidelines 

   User Information & Guidelines 

   Operating Instructions 

   Warranty & Servicing  

Notice:    This  unit  requires  a  conventional  low‐ voltage  thermostat  to  be  supplied  by  the  customer. 

A  low  voltage  thermostat,  such  as  a  Honeywell 

Model CT8775, or RTH5100, or equivalent must be  installed in conjunction with this unit. 

Page 1

CZ Infrared™ Ceramic Infrared In‐Wall Heater  

CZ‐1000F 

(Flush Mounting) 

Customer/Warranty Service: (800) 595-9605

Page 22

Warranty & Service Information

(continued)

The  Company  will  not  be  responsible  for  the  damages  or  losses,  direct  or  indirect,  caused  by  misuse,  abuse,  accident,  negligence,  conditions  of  transportation  or  storage,  or  failure  to  follow  instructions.  The  Company  will  not be responsible for any statements that are made or published, written or  oral, that are inconsistent with this written warranty, or which are misleading  or inconsistent with the facts as published in the literature or specifications by 

  the Company. 

Warranty Restriction 

This warranty is invalid if the factory‐applied serial number has been altered or 

  removed from the product. 

Warranty Claim Procedure 

 

 

To obtain warranty service, you must: 

1.  Provide proof of purchase in the form of a Bill of Sale or receipted invoice  to show evidence that the unit is within the warranty period or valid serial  number to document manufacture date, which ever is the former date will  be honored by EarthWise Technologies in lieu of proof of purchase. 

2.  Contact  the  Dealer  you  purchased  your  equipment  from  for  additional  instruction. 

 

For more information, or for additional assistance, please call or write: 

 

EarthWise Technologies, Inc. 

18324 Cook Road, Suite 6 

Yelm, Washington 98597 

 

Customer/Warranty Service: (800) 595‐9605 

©2009 EarthWise Technologies, Inc

Page 21

Warranty & Service Information

Five‐Year Limited Warranty 

EarthWise  Technologies,  Inc  (EWT)  warrants  this  product,  to  the  original  purchaser  or  gift  recipient,  to  be  free  from  defects  in  workmanship  and  materials  under  normal  use  and  service,  for  a  period  of  three  years  from  the  date of purchase. EWT further warrants the infrared heating elements, to the  original  purchaser  or  gift  recipient,  for  a  period  of  two  additional  years  from 

  the date of purchase. 

Shipping: EWT shall bear the cost of return shipping and repair, or replacement  if,  during  the  first  90  days,  there  is  a  defect  in  workmanship  or  materials. 

Thereafter,  customer  shall  bear  the  cost  of  return  shipping  and  EWT  shall  repair or replace any defective part including all labor for a period of one full  year from the date of purchase.  

 

Extended  infrared  element  warranty:  For  an  additional  two‐year  period,  EWT  shall  warrant  the  infrared  elements  in  the  heater  to  be  free  from  defects  in  workmanship and materials under normal use and service, and shall supply at  no  cost  to  the  original  purchaser  replacement  elements  as  required  to  maintain product in good working order.   

 

Limitations 

ALL  WARRANTIES  IMPLIED  BY  LAW,  INCLUDING  THE  IMPLIED  WARRANTIES 

OF  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR  PURPOSE,  ARE 

 

EXPRESSLY  LIMITED  TO  THE  DURATION  OF  THE  WARRANTY  SET  FORTH 

ABOVE. 

 

Some  jurisdictions  do  not  allow  limitations  on  the  length  of  the  implied  warranty, so the above limitation may not apply to you. 

IN  NO  EVENT  SHALL  EWT  BE  LIABLE  FOR  ANY  INCIDENTAL  OR 

CONSEQUENTIAL  DAMAGES,  LOSS  OF  PROFIT,  OR  MEDICAL  EXPENSES 

CAUSED  BY  ANY  DEFECT,  FAILURE,  MISUSE,  OR  MALFUNCTION  OF  THE 

 

PRODUCT. 

Some  jurisdictions  do  not  allow  the  exclusion  of  limitation  of  incidental  or  consequential damages, so the above limitation or exclusion may not apply to  you. 

Customer/Warranty Service: (800) 595-9605

Table of Contents

Why Use CZ Infrared™ Infrared Heat 

  Comfort Levels & Therapeutic Benefits 

  Energy Saving Benefits 

Unpacking Your New CZ Infrared™ Heater 

Installation Guidelines  

  How Many Units do I Need? 

  Installation Instructions 

  Wiring/Thermostat Instructions & Diagram 

For Your Safety/Warning  

For Best Performance 

Operating Instructions 

Maintenance 

Troubleshooting 

CZ Infrared™ Heater Specifications—CZ‐1000F 

CZ Infrared™ Heater Specifications—CZ‐500F 

Diagram of CZ Infrared™ Heater CZ‐1000F 

Diagram of CZ Infrared™ Heater CZ‐500F 

Warranty & Service Information 

Page 2

©2009 EarthWise Technologies, Inc

15 

16 

17 

13 

15 

15 

15 

18 

19 

20 

21 

Page 3

Why Use CZ Infrared

Infrared Heating

What Is Infrared Heat & How does it work? 

Infrared  heat,  by  virtue  of  its  shorter  wave  length,  is  able  to  penetrate  solid  objects  faster  than  radiant  heat.    The  advantages  of  infrared  heat  have  been  utilized  for  years  as  a  therapeutic  treatment  for  cardiovascular  and  general  circulation problems.  

 

Comfort Levels & Therapeutic Benefits of Infrared Heat 

CZ Infrared™ heats the room evenly from floor to ceiling.  Homes and Offices  with  high  ceilings  are  not  affected  by  the  difference  in  heat  displacement  between  the floor  and  ceiling.    In  other  words,  the  temperature  on  the  floor  and the ceiling remains the same without any supplemental fan circulation to  keep the temperature balanced throughout the room.  

 

The comfort levels achieved when using infrared heat are superior to those of  radiant  heating  systems.    Infrared  heat  warms the body faster  so  the  energy  that  flows  into  the  body  is  greater  than  when  being  absorbed  from  conventional  radiant  heating  sources.    Room  temperatures  of  68°F  with  infrared  feel  like  72°F  with  conventional  heating  sources  so  you  can  set  the  thermostat back 4‐5 degrees and experience the same comfort levels utilizing  less energy to keep you warm and cozy.

CZ Infrared™ heating systems are the ultimate in green technology engineering 

– affordable to purchase and economical to operate – exceptionally economical,  extremely quiet, they produce comfortable, healthy, therapeutic infrared heat. 

They are easy to install, and they look great on your wall.

CZ Infrared™  heating  systems  sterilize  the  air  that  is  processed  through  them  making  them  a  sanitary source of heat for those suffering from respiratory conditions.

With the intent of economizing and saving on building costs, most contractors  will  combine  the  heat  &  air  conditioning  ducts    into  one  distribution  system. 

This makes the cross‐contamination issue though the air conditioning ducts a  potential health problem, especially for those with respiratory sensitivities and 

  allergies, including asthma.  

The nature of the infrared wave is such that it requires localized generation of  the  infrared  wave  in  order  to  optimize the efficiency and savings produced  by  using  an  infrared  heating  source.      This  design  advantage  eliminates the need 

Customer/Warranty Service: (800) 595-9605

Diagram of CZ Infrared

Heater CZ-500F

Page 20

Parts List 

Front Cover 

Case 

Fan 

Ceramic IR Heating Element 

Fan Case 

Copper Air Guide 

Bottom Air Guide 

Fan Transformer 

Solid state relay 

High Heat Sensor 

Fan Sensor 

Connection Plate 

IR and Sensor Case Bottom 

Mounting Bracket 

Inside Insulator Cover 

Insulator 

Outside Insulator Cover 

Electrical Components Divider 

Bottom Cover 

Grill 

IR and Sensor Case Top 

Romax Wiring box 

IR Retaining clip  

Rear baffle assembly 

©2009 EarthWise Technologies, Inc

Page 19

Diagram of CZ Infrared

Heater CZ-1000F

Parts List 

A  Cover 

Case 

Heater Core 

Grill 

Fan Holder 

Fans 

Insulator Cover 

High Limit Reset 

Top Case Bracket 

 

Bottom Case Bracket 

Ceramic Heating Element 

Fan Transformer 

Baffle 

Heat Resistant Insert 

Solid state relay 

Connection Plate 

Customer/Warranty Service: (800) 595-9605

Page 4

for ductwork  to  distribute  the  heat  through  the  various  rooms  of  a  home  or  office.  Eliminating the ductwork also eliminates the dust pollen and mold that  accumulates in a conventional heat duct system.   

Energy Saving  Benefits    

Infrared heat waves are transferred more quickly throughout the room due to  their shorter wave length.   The results are impressive because it requires less  energy  to  heat  the  room  evenly  with  infrared  heat  than  with  radiant  heating  sources.  This  makes  infrared  heat  a  highly  cost‐efficient  solution  for  heating  your home.  

 

If you really want to save on energy costs, the cost of heating with CZ Infrared™  heat is going to be spectacular.  Usually a 50% savings over conventional heat  sources  is  achieved,  even  with  other  electrically  generated  heating  systems.  

As much as 65% savings is achieved if replacing heating oil or other fossil fuel  heating systems.

Quiet Operation 

CZ  Infrared™  heating  systems  operate  virtually  silently  at  over  150  cubic  feet  per minute per heating unit.  They are quieter than forced air systems and they  do not have the typical cracking and popping experienced when heating with  baseboard  heaters.    Compared  to  conventional  in‐wall  heaters  there  is  no 

  comparison  to  the  quiet  operation  of  the  CZ  Infrared™  fan  system.    Fans  are  rated at 16 dB compared to 65 dB of conventional in‐wall heating systems.

Better Heat Distribution 

The nature of the infrared wave allows the heater to be installed higher on the  wall  than  conventional  in‐wall  heater  systems  without  compromising  the  transfer of the heat to the floor.  The advantage of the higher installation on 

  the wall guarantees that furniture and other obstructions to the airflow from  the heater are eliminated. Child tampering is also eliminated.   

Even distribution of the infrared wave is also assured since the air space above  the  furniture  is  virtually  unrestricted.    When  conventional  heat  sources  are  vented  through  the  ceiling  to  economics  and  save  on construction  costs,  the  heat remains on the ceiling and must be pushed to floor with ceiling fans.  This  is not required with infrared heat. 

©2009 EarthWise Technologies, Inc

Page 5

Accurate Temperature Regulation 

The  CZ  Infrared™  heating  system  utilizes  state  of  the  art  electronics  and  internal power sourcing to accept a low‐voltage thermostat of your choosing.  

 

Low voltage wall thermostats provide more accurate temperature control and  can be linked to a central control system if desired. 

The  unique  low‐voltage  thermostat  controls  on  a  CZ  Infrared™    heater  allow  the heater to be linked to a central zoned control system without modification  or  special  switching  devices  to  control  the  voltage  to  the  heating  elements  themselves. This feature allows the CZ Infrared™ system to be operated in the  most  economical  manner  possible  by  utilizing  the  infrared  heat  only  in  those  spaces  which  are  currently  being  occupied  and  require  the  heat.    Zoned 

  heating  is  as  much  as  50%  more  economical  to  use  when  the  entire  home  or  office does not require heat in all areas 100% of the time.  The cost savings from  this feature alone makes initial installation of the CZ Infrared™ heating system  pay for itself in a matter of months. 

Cost‐Effective to Install 

* Components in the CZ Infrared™ heating system are designed to last 10 times  longer than other in‐wall heaters.  CZ Infrared™ warranty coverage and service  procedures are simple to follow and they can be serviced in ten minutes or less  should repair be required.

*  The  cost  to purchase  and install  a  CZ  Infrared™  infrared  heating  system  for  your entire home is usually much cheaper than the cost of installing a central 

  forced air heating system. 

Stylish & Functional 

The  CZ  Infrared™  heater  service  panel  and  wall  registers  are  stylish  and  functional with a modest design flare making them more favorable for custom‐ home installation than conventional registers and intake ducts.  The designer 

  panel  on  the  wall  register  can  be  left  white  or  custom  painted  to  match  or  contrast the walls. 

Patented Proprietary Technology 

CZ  Infrared™  heaters  contain  a  proprietary  high‐efficiency,  ceramic  infrared  emitter ( or heating element) which produces more infrared heat per kilowatt 

  than conventional ceramic. quartz, or carbon plates. 

Customer/Warranty Service: (800) 595-9605

Page 18

CZ Infrared

Heater Specifications

Model CZ‐500F 



Cabinet: All Metal –22 & 24 gauge 



Weight: 8.0 lbs 



Dimensions: 18” x 4  3 /

8

” x 4” (H,W,D) 



Power Requirements: 120 Volt AC —500 Watt.  



Power Supply: Requires isolated 12 gauge wire to fuse panel. 



Chassis Safety Insulation: Exceeds all government and  independent laboratory standards for safety in an installed  heating appliance (a safety standard that exceeds other  manufacturer’s specifications).  



Internal ceramic blanket provides R45 insulation between the  wall and the heater. The heater cabinet installed in the wall  remains cool to the touch while delivering warm (160° F)  infrared heat into the room. 



Life Expectancy: CZ Infrared heaters—25 years+. 



Thermostat Power Requirement: None. The unit contains its  own low voltage power supply for thermostat operation. 



Thermostat Type: Any 12‐24 volt low‐voltage thermostat (not 

 supplied). 

Zoned Heat Capability: Pre‐wired.  Simple two‐wire contact to 

CZ-500F any zone control panel—can also accept multiple parallel hook‐ups to a single low‐ voltage thermostat. 



Safety Cut‐Off: Yes. 



Listed Approvals: CTUV‐US & International (UL Equivalent). 



Installation: Any wall with a minimum 3 ½ inches of depth. 



Heat Type: Therapeutic far‐infrared heat. 



Heat Chamber copper lined for maximum ion transfer. 



Heating Elements: One (1) ceramic infrared emitter 500 w. 



Ceramic Life Expectancy: Rated at 40,000 hours. 



Heat Output: 2,800 BTU infrared heat. 



Fan System: One (1) high volume, low noise 90mm DC fan. 



Frequency Hum: There is no AC 60Hz frequency hum as with other in‐wall systems. 



Fan Noise Level: 18 dB—practically silent. 



Warranty: Limited 3 Year P & L. 5 Year—ceramic emitters. 

©2009 EarthWise Technologies, Inc

Page 17

CZ Infrared

Heater Specifications

Model CZ‐1000F 



Cabinet: All Metal –22 & 24 gauge 



Weight: 13.0 lbs 



Dimensions: 16” x 12  5 /

8

” x 4” (H,W,D) 



Power Requirements: 120 Volt AC  —1000 Watt.  



Power Supply: Requires isolated 12 gauge wire to  fuse panel. 



Chassis Safety Insulation: Exceeds all government  and independent laboratory standards for safety  in an installed heating appliance (a safety standard  that exceeds other manufacturer’s specifications).  



Internal ceramic blanket provides R45 insulation  between the wall and the heater. The heater cabinet 

CZ-1000F installed in the wall remains cool to the touch while delivering warm (160° F)  infrared heat into the room. 



Life Expectancy: CZ Infrared heaters—25 years+. 



Thermostat Power Requirement: None. The unit contains its own low voltage  power supply for thermostat operation. 



Thermostat Type: Any 12‐24 volt low‐voltage thermostat (not supplied). 



Zoned Heat Capability: Pre‐wired.  Simple two‐wire contact to any zone control  panel—can also accept multiple parallel hook‐ups to a single low‐voltage  thermostat. 



Safety Cut‐Off: Yes. 



Listed Approvals: CTUV‐US & International (UL Equivalent). 



Installation: Any wall with a minimum 3 ½ inches of depth. 



Heat Type: Therapeutic far‐infrared heat. 



Heat Chamber copper lined for maximum ion transfer. 



Heating Elements: Two (2) ceramic infrared emitters 500 w., 500 w. 



Ceramic Life Expectancy: Rated at 40,000 hours. 



Heat Output: 4,800 BTU infrared heat. 



Fan System: Three (3) high volume, low noise 90mm DC fans. 



Frequency Hum: There is no AC 60Hz frequency hum as with other in‐wall systems. 



Fan Noise Level: 18 dB—practically silent. 



Warranty: Limited 3 Year P & L. 5 Year—ceramic emitters. 

Customer/Warranty Service: (800) 595-9605

Page 6

Patent pending coverage of more than 30 distinct features in the CZ Infrared™  

  heater  are  what  makes  the  CZ  Infrared™  technology  a  truly  unique  energy  efficient heat source for your home or office. 

Flexible Size & Voltage Applications 

 

CZ Infrared™ heating systems come in 120 volt units for new construction.  The 

120 volt units are designed to be retrofitted to existing installations where only 

120 volt circuitry is available.   

 

CZ  Infrared™    heaters  come  in  two  sizes:  1000  watts  for  conventional  room  heating and 500 watts for bathrooms, hallways and closets.   

CZ‐1000F ‐ 1000 watts 

CZ‐500F ‐ 500 watts 

 

Quality Assurance 

CZ  Infrared™  heating  systems  come  with  C‐TUV‐US  certifications  with 

  equivalent approvals both in UL and CSA classifications. CZ Infrared™ heaters  are manufactured in Taiwan and China by EarthWise Electronics, Inc.  

©2009 EarthWise Technologies, Inc

Page 7

Unpacking Your New CZ Infrared

Heater

1.  FIRST, inspect the package for any obvious damage. 

2.  Remove the protective packaging materials from the outside of the heater  cabinet and from the front face panel. 

3.  Remove the protective packaging materials from the inside of the heater’s  heat  exchanger,  making  sure  that  all  combustible  materials  have  been  removed from around the black ceramic heating elements. 

4.  Inspect the unit to make sure that there are no crack in the black ceramic  heating elements. 

5.  If no obvious damage is visible, proceed with the installation instructions  as outline in the Installation Guidelines included with this manual. 

Installation Guidelines

How Many Units Do I Need?

 

 

When determining the right number of units to install in a conventional home,  the following items need to be taken into consideration:   

 

 The insulation factor, and window size & placement 

 The mean outside temperature during the coldest days of the year 

 The size of each room 

 The overall size of the home 

 The number of floors involved 

 The Entrance and Egress points 

 

In  lieu  of  overall  engineering  calculations  and  thermal  loss  calculations,  a  general rule of thumb can be applied to determine the number of units to be  installed: 

 

Notes: Calculate 4‐6 hours of running time per day per heater installed to calculate Btu’s  and electrical energy cost. Also, remember that multiple unit installations in larger rooms  can be coupled to the same low‐voltage thermostat or regulated separately.

Customer/Warranty Service: (800) 595-9605

Page 16

Troubleshooting Your CZ Infrared

Problem  Solution 

Heater is noisy 

Check for obstructions to the fan blades.  

If there are none, you have a defective fan  and must first isolate the defective fan  unit for replacement.   

Call a service technician for installation. 

Heater won’t turn on 

First, push the reset button. Next, check  the thermostat leads.  Short the leads out  and if the heater turns on you have a  defective thermostat, otherwise you have  a defective relay in the heater.   

Call a service technician for installation of  a new relay. 

Heater fan remains running after 

20 minutes of shut‐down 

Most likely you have a defective fan relay. 

Call a service technician for installation. 

Heater doesn’t appear to be  getting hot enough 

Heater does not heat‐up 

Most likely one of the ceramic elements is  burnt  out  or  the  connection  to  the  element  is  bad.    Call    a  service  technician  to  determine  the  cause  of  the  problem  and  if  necessary  replace  the  defective  ceramic plate. 

First,  push  the  reset  button.  Next,  check  the thermostat leads & listen to determine  if  the  first  fan  is  operating.  If  so,  call  a  service technician for installation of a new  heat relay. 

©2009 EarthWise Technologies, Inc

Page 15

For Your Safety/Warning

Do not place objects in front of infrared wall units that have been mounted lower than  those parameters suggested in the installation instructions. Doing so will cause the unit  to overheat, which will trigger the high temperature limit switch, resulting in a potential  service call to reset/replace the switch. 

For Best Performance

It is recommended that the air flow pattern in the room becomes circular. This is  accomplished by mounting the heater to one side of the room, as per the illustration, in 

  order to create a circular flow around the room.  

Where multiple units are installed in larger rooms, this circular pattern can be  maintained by positioning the units to complement the air flows. This is accomplished  by positioning them in opposite corners of the room. 

Operating Instructions

The units are self‐regulating. Temperature is controlled via a low‐voltage thermostat  located preferably on the opposite wall from the heating unit. The heater fans will turn  on when the power to the infrared heating elements turn on. After the heating  elements have come up to full temperature, a third fan will turn on to increase the  airflow into the room. This third fan will remain running even after the heating  elements have been shut down by the thermostat, in order to distribute the remaining 

  heat in the heating elements into the room. 

Temperatures can be regulated from a central control (sold separately) or the heating  units can also be independently turn on or off from a remote location via a central on/ off switch for each unit. The switch is connected between the low‐voltage thermostat  control and one of the lead wires to the thermostat from the thermostat contact on the  heater. 

Maintenance

Routinely inspect the air registers on the infrared unit to make sure that there is no dust 

  accumulation. Vacuum as you would any conventional heat or air conditioning duct. 

It is suggested that an annual dusting of the ceramic plates be performed in order to  eliminate any residual accumulation of dust during the summer months. Other than  this, there are no maintenance requirements involved. In order to accomplish this, the  front plastic panel must be removed by removing the four screws and lifting up to  release the panel from the top clip. 

Customer/Warranty Service: (800) 595-9605

Page 8

 

New construction (coldest day above 5 degrees),   standard insulation, one window per room: 

Room size below 250 sq. feet: 1 ‐ 1000 watt unit 

Room size above 250+ to 500 sq. feet: 2 ‐ 1000 watt units 

Room size above 500+ to 750 sq. feet: 3 ‐ 1000 watt units 

Room size above 750+ to 1000 sq. feet: 4 ‐ 1000 watt units 

Room size above 1000+ to 1250 sq. feet: 5 ‐ 1000 watt units

New construction (coldest day below 5 degrees)  

 

& all remodels, standard insulation: 

Room size below 200 sq. feet: 1 ‐ 1000 watt unit 

Room size above 200+ to 400 sq. feet: 2 ‐ 1000 watt units 

Room size above 400+ to 600 sq. feet: 3 ‐ 1000 watt units 

Room size above 600+ to 800 sq. feet: 4 ‐ 1000 watt units 

Room size above 800+ to 1000 sq. feet: 5 ‐ 1000 watt units 

Room size above 1000+ to 1200 sq. feet: 6 ‐ 1000 watt units 

 

Hallways and Nooks1 ‐ 500 watt unit per 100 sq. feet 

Closets and Bathrooms1 ‐ 500 watt unit per 100 sq. feet 

Installation Instructions for 1000 watt unit

 

Required outlet opening: The heater cut‐out must have a minimal size of  12.5 in. 

 

W x 16 in. H x 3.5 in. D in order to accommodate the heater. 

Mounting the Heater

 

The heater comes with two sets of mounting brackets.  Using the appropriate  set of brackets for the mounting conditions, attach the heater unit to the wall  preferably  6  ft.  above  the  floor  to  eliminate  obstructions  to  air  flow.      The  heater can be mounted lower if preferred.  The higher location of the heater  also insures that obstacles in the room such as furniture will not encumber the  circulation of the infrared heat waves being generated from the heater.  This  assures even heat distribution and prevents cold‐pockets of air.  The infrared 

  heat will flow evenly from floor to ceiling so the location of the heater on the  wall is not pre‐empted by normal in‐wall heater considerations. 

Note:  Each CZ Infrared™ heater comes with two sets of mounting brackets.  One  set is for mounting the unit prior to sheet rock installation, and the second set is 

for mounting the unit after sheetrock installation, as in the case of a remodel. 

©2009 EarthWise Technologies, Inc

Page 9

Mounting Guidelines (CZ-1000F)

CZ‐1000F New Construction Installation 

OPTIMAL

SITE

OPTIONAL

SITE

Wiring Diagrams

*

BLUE

WHITE

Page 14

RED

CZ‐1000F Wiring Schematic 

* Switch must be having a contact separation in all poles that provide full disconnection with a  contact separation of at least 3 mm and rated 10A minimum. 

 

Heater must not be located immediately below a socket‐outlet. 

Use the following  mounting brackets   for heater installation  prior to sheetrock  installation. 

Use the new construction brackets as shown. Attach the heater unit to the  wall, 6 ft. (1.8 m) or higher above the floor to the bottom of the heater unit.  

The higher the better. The higher location of the heater insures that obstacles  in the room such as furniture will not encumber the circulation of the infrared  heat waves being generated from the heater.  This assures even heat  distribution and prevents cold‐pockets of air.  

Customer/Warranty Service: (800) 595-9605

RED

BLUE

WHITE

CZ‐500F Wiring Schematic 

©2009 EarthWise Technologies, Inc

Page 13

Installation Guidelines (continued)

Heater Wiring  

Regardless of the model chosen, there are 5 wires inside the base of the heater which  must be wired correctly. Three wire contacts are required to obtain the power source.  

 

The wiring code is the same for 120 volt units.  

The heater must be provided disconnect device (switch/breaker) from the supply mains  having  a  contact  separation in all  poles  that  provide  full  disconnection  with a  contact 

  separation of at least 3 mm. 

On the large in‐wall unit the black is hot, the red is neutral, and the green is ground. On  the  small  in‐wall  unit  the  black  is  hot,  the  blue  is  neutral  and the  green  is  ground.  On 

  both units the yellow and white wires go directly to the thermostat.   

 

No external power supply is needed.  Any attempt to attach an external power supply  will cause damage to the internal components and will result in product failure.   

When connecting multiple units to a single thermostat, the units must be connected in  parallel  with  all  yellow  and  all  white  wire  leads  connected  to  their  same  respective 

  terminals on the thermostat.   

Failure to follow these guidelines will result in internal transformer failure and product  failure.   

 

The figures below depict a typical wiring procedure using conventional 12/2 wire on a large heater. 

Page 10

Mounting Guidelines (CZ-1000F)

CZ‐1000F Existing Construction Installation 

OPTIMAL

SITE

OPTIONAL

SITE

 

 

 

 

 

 

 

 

 

 

 

The heater cutout 

 

  should have a  minimal size of  

16 

1

/

2

 (h) x 12 

3

/

4

 (w). 

Use the following   mounting brackets   for heater installation   in existing construction. 

 

Thermostat Wiring 

Use  any  conventional  thermostat  or  doorbell  wire  to  route  the  thermostat  to  the  heater.    Unless  the  thermostat  is  diode  protected  or  voltage  sensitive  to  DC  (positive  and  negative), it  doesn’t  matter  which  heater thermostat  wire  goes to  the  respective 

  contacts on the back of thermostat.   

Consult the wiring instructions that are included with the thermostat to make sure that  the  low  voltage  thermostat  being  used  is  compatible  with  the  12  volt  DC  voltage  originating  from  the  yellow  and  white  thermostat  wires  from  the  heater.    The  thermostat should be located at least 5 feet from the location of the in‐wall heater. 

Customer/Warranty Service: (800) 595-9605

 

Use  the  retrofit  brackets  as  shown.  Attach  the  heater  unit  to  the  wall,  6  ft.   

(1.8 m) or higher above the floor to the bottom of the heater unit.  The higher  the better. The higher location of the heater insures that obstacles in the room  such as furniture will not encumber the circulation of the infrared heat waves  being  generated  from  the  heater.  This  assures  even  heat  distribution  and  prevents cold‐pockets of air. 

©2009 EarthWise Technologies, Inc

Page 11

Mounting Guidelines

(CZ-500F)

CZ‐500F New Construction Installation 

Page 12

Mounting Guidelines

(CZ-500F)

CZ‐500F Existing Construction Installation 

 

 

 

 

 

 

 

 

 

 

 

The heater cutout 

  should have a 

1 minimal size of 18 

/

2

 (h) x 4 

7

/

8

 (w). 

Use the following  mounting brackets for  heater installation in  existing construction.  

Heater must not be located immediately below a socket‐outlet. 

The heater is to be installed so that switches and other controls cannot be 

 

 

 

 

 

  touched by a person in the bath or shower.  

Use the following  mounting brackets   for heater installation  prior to sheetrock  installation. 

 

 

 

 

 

 

Use the new construction brackets as shown. Attach the heater unit to the  wall, 6 ft. (1.8 m)  or higher above the floor to the bottom of the heater unit.  

The higher the better. The higher location of the heater insures that obstacles  in the room such as furniture will not encumber the circulation of the infrared  heat waves being generated from the heater. This assures even heat  distribution and prevents cold‐pockets of air. 

Customer/Warranty Service: (800) 595-9605

Use the retrofit brackets as shown. Attach the heater unit to the wall, 6 ft.   

(1.8 m) or higher above the floor to the bottom of the heater unit.  The higher  the better. The higher location of the heater insures that obstacles in the room  such as furniture will not encumber the circulation of the infrared heat waves  being generated from the heater. This assures even heat distribution and  prevents cold‐pockets of air. 

©2009 EarthWise Technologies, Inc

advertisement

Related manuals

advertisement