Monarch Water WELLBEING CAPRICORN is a 5-stage water filtration system designed to produce clean, pure drinking water. It utilizes a combination of sediment, carbon, and reverse osmosis (RO) filtration to remove impurities and contaminants from tap water. The system features a pressure tank that stores purified water and a faucet for convenient dispensing. The unit comes with a comprehensive installation manual and requires regular filter replacement for optimal performance.
PDF
Download
Document
Advertisement
Advertisement
IMPORTANT READ BEFORE COMMENCING INSTALLATION / HOW YOUR SYSTEM WORKS ALL CAPRICORN UNITS MUST BE INSTALLED BY A COMPETENT PERSON. / UNIT SPECIFICATIONS / CONTENTS OF PACKAGE Voltage and Frequency: 11 0V-240V 50Hz/60Hz Wattage: 25W-36W RO Element Capacity: 50/75/100/125/150GPD Tank Capacity : 3.2G Steel or 3.0G Plastic Inlet TDS: ≤ 250ppm Chlorine Level: ≤ 0.2ppm Average RO Rejection Rate: 98% Inlet Water Pressure (min/Max): 14.5 - 43.5 psi Inlet Water Temperature (min/Max): 5 ° C - 45 ° C Flush Type (model dependent): Auto or Manual Reverse Osmosis Unit - 1 pc Housing Wrench - 2 pcs Food Grade Tubing - 4 pcs (Red, White, Yellow, Blue) Faucet - 1 pc Accessories- Drain Clamp, Tee Fitting, Ball Valve, Feed Water Valve RO Membrane -1 pcs Manual -1 pcs / 5 STAGE FILTRATION / RECOMMENDED TOOLS NEEDED FOR INSTALLATION Knife Electric drill Hammer Seal tape Monkey wrench Scissors The stages and their functions are outlined below • First Stage / Spun PP Filter -removes larger particles suspended in water. • Second Stage / Granular Carbon Filter - removes organics, chlorine, odour, and turbidity. • Third Stage / Block Carbon Filter - further removes any organics, chlorine, odour and turbidity. • Fourth Stage / RO Membrane -removes bacteria, heavy metals, dissolved matter, and salinity. • Fifth Stage / lnline Carbon Filter (post filter) -adjusts the taste of treated water. / BEFORE YOU START • • • • • • • Read through all instructions before beginning installation and using this system. Follow all steps exactly or risk damaging system/incorrect operation. This system contains filters that need to be replaced at certain intervals. Replacement intervals will vary according to use, please contact your local dealer for details. Please install system on potable water only. On non-potable water sources, system will not function properly and additional pre-treatment may be needed. Ensure source water pressure is between 14.5 - 43.5 psi. If source water pressure exceeds maximum pressure a pressure reduction valve may be needed, consult your local dealer. Ensure source water temperature is between 5°C - 45°C. System will not function properly if these temperatures are exceeded. DO NOT INSTALL ON HOT WATER SOURCE. Do not use system on noticeably contaminated water such raw sewage or well water. This unit operates on 110V-240V power. Please ensure you are using the correct power source. / WARNING • • • • 2 Do not disassemble, open, or modify this unit. Tampering with the unit may cause failure or damage and will void warranty. Do not cover the unit, as this will prevent proper heat dissipation and can cause damage or fire. Do not place objects on top of the unit as this may cause damage to the unit and may cause leaking. Follow all recommended operating pressures and temperature, failure to do so will cause damage to the unit and void warranty. monarchwater.co.uk monarchwater.co.uk 3 / UNIT PLACEMENT / DRAIN CLAMP ASSEMBLY The unit can be placed flat or upright and on top, inside, or under the cabinet. Feed Water connection should be as close as possible to unit. However, if due to space or other limitations, this unit can be placed where it is convenient. When choosing a location for the unit, remember to have easy access to cold water line, drain pipe, power outlet, and enough room to change filters. All components and tubing should be located in an area not exposed to freezing temperatures or direct sunlight. NOTE: All components and tubing should be located in an area not exposed to freezing temperatures or direct sunlight. / FEED WATER VALVE AND TEE FITTING / DRAIN CLAMP INTRODUCTION A Drain Clamp is used to make a wastewater connection with the drain under the sink, and is designed to fit around a standard 40mm OD drainpipe. The drain saddle valve should always be installed before (above) the p-trap and on a vertical or horizontal drain. To avoid clooing the drain line with drbris, do not install the drain saddle near a garbage disposal. • • • • • Install Tee Fitting Valve shown below to your 15mm cold water pipe. Attach the grey plastic adapter to the male thread on the tee fitting. Apply sealant to olive as shown in right hand picture below. Ensure the compression fittings and the grey fitting are secured tight to seal Connect White Feed Water Tubing from unit to Feed Water Valve. / WARNING Ensure chrome nut compression and grey plastic adapter are tight to seal. / DRAIN CLAMP INSTALLATION Position drain clamp on drain pipe above the drain trap and tighten securely. Using the drain clamp as a guide, drill a 6mm hole, enough for the 1/4” tubing to pass, through one side of the drain pipe. DO NOT drill through both sides. Connect Red Waste Water Tubing from unit to Drain Clamp. / NOTE When cutting the tubing make clean, square, cuts, failing to do so result in poor connection and possible leaks. / WARNING The lowest point of the line should be the point of connection to the Drain Clamp. There should be no sag in the line as this may cause excessive noise as the reject water is flowing to drain. 4 monarchwater.co.uk / NOTE Use only a cold potable water supply as Feed Water, hot water will damage your unit. Softened Feed Water will extend the life of the RO Membrane. monarchwater.co.uk 5 / PRESSURE TANK / INSTALL PRE-FILTERS Keep pressure tank within 10 feet of faucet. If longer length of tubing is needed, use 3/8” tubing only to prevent pressure drop. Tank can weigh up to 30lbs when full, find firm and level flooring. Install Ball Valve by screwing Valve on to Tank and apply Teflon tape to prevent leaking. Connect Yellow tubing from post filter to Pressure Tank. - Remove Pre-Filters from packaging. - Place filters in appropriate housings according to labels and install filter housing from right to left in the following order: PP, GAC, CTO. - Tightening housings with wrench provided. / NOTE RO membrane is not to be installed until after pre-filter flush has been complete. / NOTE When installing housings make sure housing is level and even to avid leaking. / TANK INSTALLATION • • Hand tighten plastic. Shut-off valve to tank. / FAUCET INSTALLATION / WHERE TO PLACE YOUR FAUCET The faucet should be placed in a convenient area near the sink tap. There should be a reasonable amount of space above and below the faucet mounting position to allow to connections to the RO unit. There should be a 2” diameter area for the faucet to be mounted. The thickness of mounting surface should not exceed 32mm. / OPERATION AND MAINTENANCE Pre-filter Flushing (initial setup, before installing RO Element) Prepare system for operation by flushing pre-filters: • Disconnect RO element inlet tube on element housing cap. Open water main and inlet valve and allow system to run through the 3 pre-filters. • Discard output water into container or drain. • Continue flushing until output water is visibly clean. Reconnect tube. Select a convenient location near your sink to place the faucet. Drill a hole 12mm in diameter into the counter top. Place washers, plates, seals and nuts in order as per diagram and tighten on the countertop. Screw the grey plastic adapter on the bottom of the faucet. Note: Pump and membrane may be severely damaged if system is run without flushing pre-filters. Discard all water from flush, it is not suitable for use or consumption. Attach the Blue Pure Water tubing to the grey plastic adapter on the bottom of faucet and connect tubing to unit. 6 • • • monarchwater.co.uk After flushing pre-filters connect and open all valves. Wait approximately 2 minutes before opening faucet. Allow system to flush for first 10-15 minutes with faucet open. Do not use water from RO unit at this time. monarchwater.co.uk 7 / RO MEMBRANE INSTALLATION / MEMBRANE REPLACEMENT / NOTE Close Feed Water Valve. Close Tank Ball Valve on Pressure Tank. • Open Faucet and drain any remaining water from system. • Open membrane housing and remove used membrane. • Follow the same procedure as RO membrane installation to replace RO membrane. Before proceeding with membrane element installation, please flush pre-filters thoroughly. (See previous step) • • • • Remove RO housing cap using wrench. Remove RO element from packaging. Insert RO element into housing with the small double O rings facing inward. Install membrane housing cap and tighten with wrench provided. / FLUSHING THE PRESSURE TANK • • • After flushing the Pre-Filters, allow the unit to operate and fill the Pressure Tank. Tank will take approximately 3.5 hours to fill. Once tank is full, discharge Pressure Tank by leaving faucet open. Once Tank is completely empty, close faucet and allow tank to fill again. After the Pressure Tank has been flushed, the unit is ready for use. / FILTER MAINTENANCE To ensure the unit operates at its optimum level, routine maintenance is required. The frequency of maintenance depends on the feed water quality and amount if system usage. The follow are some guidelines for scheduled filter changes, keep in mind the frequency of filter changes may vary. If in doubt, contact your local dealer or service technician. • • Change all cartridges every 6 months. Change membrane as requested. If you will be away or not using the unit for an extended period of time, please disconnect unit from power supply. If the unit has been shut down and not used for an extended period of time, perform the same flushing procedure as in the initial set up. / FILTER REPLACEMENT • • • • • • Close Feed Water Valve. Close Tank Ball Valve on Pressure Tank. Open Faucet and drain any remaining water from system. Disconnect quick connect filters. Replace filters, reconnect, and open valves. Perform pre-filter flush after filters have been changed / NOTE Diagrams on how to connect using quick connect fittings can be found in the installation section. 8 monarchwater.co.uk monarchwater.co.uk 9 / DISCLAIMER / TROUBLESHOOTING In case of special circumstances during installation, you need to use accessories not included in the packing list of this product. Consumers are asked to purchase quality-guaranteed accessories through regular channels. Monarch Water is not responsible for the quality of non-original accessories because of the quality problems of the accessories purchased by consumers. Monarch Water assumes no responsibility for any water leakage accident. / REGULAR MAINTENANCE Please ensure you change your filters when recommend. Failure to change your filters regularly may invalidate your warranty. Regularly check the TDS level of your output water. Ensure that you change your Reverse Osmosis Membrane when recommend or when the TDS level starts to rise. For best performance, supply unit with softened water, as this will achieve maximum life expectancy of the membrane. / SAFETY INSTRUCTIONS This appliance is intended to operate and function as per the instructions in this manual. It is not designed to operate outside of the specifications listed and any attempt to do so or tamper with the unit can cause damage to the unit and/or bodily harm. This unit is not a toy, keep out of reach from small children. If the unit requires service or repair, please contact your local service technician or sales representative. • Please ensure feed water temperature is over 4 °C. Using water below 4 °C can cause ice to form and damage the unit. • Please ensure power source is correct before connecting unit. Incorrect voltage could result in damage to unit and/or fire hazard. • Do not cause damage to or use unit if the power cord is damaged. A damaged power cord could cause an electrical shock or fire hazard. If power cord is damaged, unplug and discontinue use immediately. 10 monarchwater.co.uk monarchwater.co.uk 11 TO ORDER SPARE PARTS Please contact your dealer for more information. + 44 (0) 1986 784759 monarchwater.co.uk [email protected] ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- 5-stage filtration
- RO membrane
- Pressure tank
- Faucet
- Easy installation
Frequently asked questions
The installation process is detailed in the manual. It involves connecting the unit to a cold water supply, drain pipe, and power outlet, and then installing the pre-filters and RO membrane.
It is recommended to change all cartridges every 6 months, and the RO membrane as requested. The frequency of filter changes may vary depending on the quality of your feed water and the amount of system usage. Consult your local dealer for details.