ClearCube F6151 User`s manual

ClearCube F6151 User`s manual
Add to My manuals

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

Manual
ClearCube F6151 User`s manual | Manualzz

ClearCube FO-065-1200 series 12-Port Media Converter

ClearCube®

F6151

Media Converter Chassis System with

10/100BaseTX to 100BaseFX Converter

User’s Manual

1

ClearCube Connectivity Systems

F6151

Media Converter Chassis System with

10/100BaseTX to 100BaseFX Converter

User’s Guide

ClearCube F6151 Media Converter and Chassis System

Table of Contents

Table of Contents ........................................................................ i

FCC Warning ............................................................................ iii

CE Mark Warning ..................................................................... iii

Trademarks................................................................................ iii

Preface....................................................................................... iv

Package Contents ...................................................................... iv

Chassis Overview........................................................................... 1

ClearCube F6151 Media Converter Chassis System...................1

Product Features..........................................................................1

Front Panel Display.....................................................................3

Front Panel ..............................................................................3

Understanding LEDs ...............................................................3

Installation ..................................................................................... 4

Selecting a Site for the Equipment ..............................................4

Deciding How to Install the System............................................5

Mounted to 19-inch standard rack...........................................5

Desktop or any flat surface......................................................5

Replacing Media Converters in a Chassis ...................................6

Connecting to Power ...................................................................7

Power supply ...........................................................................7

Connecting to power ...............................................................7

Cooling System ...........................................................................8

Media Converter Overview .......................................................... 9

Product Overview........................................................................9

Product Features..........................................................................9

One-Channel Media Converter.................................................. 10

Ports ..........................................................................................10

Port Settings ..............................................................................10

DIP switch.............................................................................10

Front Panel & LEDs..................................................................11

LED Indicators ......................................................................11

User’s Guide i

ClearCube F6151 Media Converter and Chassis System

Specifications ............................................................................... 13

Chassis System......................................................................13

Power Supply ........................................................................13

Media Converter....................................................................13

Support......................................................................................... 15

ii User’s Guide

ClearCube F6151 Media Converter and Chassis System

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user must correct the interference.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.

All rights reserved. All brand names are registered trademarks of their relative holders.

Trademarks

Product names mentioned in this manual may be trademarks or registered trademarks of those products and are hereby acknowledged.

• Ethernet is a trademark of Xerox Corporation.

• Microsoft Windows is a trademark of Microsoft Corporation.

User’s Guide iii

ClearCube F6151 Media Converter and Chassis System

Preface

This manual describes how to install and use the ClearCube F6151

Media Converter and Chassis System. The system introduced here is capable of housing up to sixteen media converters, each of which offers one channel media conversion solution:

• 10/100BaseTX ↔ 100BaseFX

• 100BaseTX ↔ 100BaseFX

The ClearCube Ethernet Media Converter fully complies with

IEEE802.3 10BaseT and IEEE802.3u 100BaseTX/FX standards.

In this manual, you will find:

• Introduction on the Chassis System

• Product features

• Illustrative LEDs functions

• Installation instructions

• Specifications

Package Contents

When you unpack the product package, you shall find these items listed below.

• ClearCube F6151 Media Converter Chassis System, consisting of one chassis with 16 media converters

• Two power supplies installed on the chassis

• AC power cord

• User’s Manual

• Accessories: rackmount screws, brackets, & bracket screws

• Media converter carriers, fitted to each bay

Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller. iv User’s Guide

ClearCube F6151 Media Converter and Chassis System

Chassis Overview

ClearCube F6151 Media Converter Chassis

System

Figure 1: Chassis and converters equipped with two power supplies

Product Features

H

OUSES SIXTEEN MEDIA CONVERTERS

F

RONT PANEL LED S FOR POWER STATUS

S

TANDARD 19” RACKMOUNTABLE SIZE , 2U

N

ON STOP OPERATION & MINIMAL DOWNTIME

H

OT SWAPPABLE

The following items are designed to be hot swappable to allow easy and quick replacement:

- Media converters

- Power supplies with fans

A

DEQUATE VENTILATION

- Provides one cooling fans on the left and right side

- Ventilation holes on each side

P

OWER REDUNDANCY & POWER ISOLATION

User’s Guide 1

ClearCube F6151 Media Converter and Chassis System

Two high quality internal power supplies provided for loadsharing purpose.

- Load sharing mechanism: If one power supply should fail, the redundant power supply is capable of taking over immediately

- Converter bay power isolation ensures each bay is electrically isolated from each other

O

VER CURRENT PROTECTION

- Fuses on PCB for each converter bay

- Fuse on each power supply

2 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Front Panel Display

F RONT P ANEL

The front panel of this ClearCube F6151 Media Converter Chassis

System shows it with sixteen media converters in bay 1~16.

There are two LED indicators on the left side of the front of the chassis that indicate the status of each power supply.

Figure 2: Front panel of ClearCube F6151 Media Converter Chassis System

U NDERSTANDING LED S

Power

Supply’s

Switch LED

Green

Off

Power switched on

Power switched off

Blown fuse

Power supply failed

L

Before you use this table for troubleshooting, make sure the chassis system is properly connected to power and switched on.

User’s Guide 3

ClearCube F6151 Media Converter and Chassis System

Installation

Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:

• The ambient temperature should be between 32 and 104 degrees Fahrenheit (0 to 40 degrees Celsius).

• The relative humidity should be less than 90 percent, non-condensing.

• Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2

(3V/M) field strength.

• Make sure that the equipment receives adequate ventilation.

Do not block the ventilation holes on each side of the switch or the fan exhaust port on the side or rear of the equipment.

• The power outlet should be within 1.8 meters of the switch.

4 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Deciding How to Install the System

The accessories supplied in the product package include: rackmount screws, rackmount brackets, and bracket screws.

This well-built chassis can be installed in the following ways:

M OUNTED TO 19INCH STANDARD RACK

Use the rackmount brackets and screws to install the chassis into any EIA 19” standard rack.

Step 1: Attach the brackets to each side of the chassis. Apply screws to each side and secure them tightly.

Step 2: Carefully position the chassis into the rack. Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack.

Step 3: Proceed to the “Connecting to Power” section.

D ESKTOP OR ANY FLAT SURFACE

The chassis can sit on desktop or any flat surface with adequate space and ventilation. If you want to place it onto a shelf, make sure the shelf can withstand a minimum weight of 10kg.

Step 1: Simply put the chassis on the desired place.

Step 2: Ensure the chassis receives good ventilation.

Step 3: Proceed to the “Connecting to Power” section.

User’s Guide 5

ClearCube F6151 Media Converter and Chassis System

Replacing Media Converters in a Chassis

The chassis is shipped containing 16 media converters. Each media converter is attached to a media converter carrier, which is already fitted into bays of the chassis.

The following steps describe how to attach a media converter carrier to a media converter if you need to replace a media converter.

Step 1:

To install a media converter onto any of the carriers, you

have to unscrew the carrier from the desired bay first.

Step 2: Fit the media converter onto the carrier.

Step 3: When the media converter is completely seated onto the carrier, insert the carrier to the guide rails of the bay slot.

Step 4: Carefully slide in the carrier until it is fully and firmly fitted to the power socket. Fasten the screws on the carrier.

L i. The chassis is designed to house only the proprietary media converters. ii. Never insert any media converter into the chassis directly without using the supplied carriers. These carriers allow secure and consistent placement of the media converters into the chassis’ backplane without causing any damage. iii. For details, please refer to the User’s Manual for media converters.

For more information about media converters, see “Media

Converter Overview” on page 9.

6 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Connecting to Power

P OWER SUPPLY

The chassis ships with two power supplies. When the chassis is equipped with two power supplies, you can have the following advanced performance.

Hot Swappable

The design of the power system is based on an idea of providing maximum flexibility and redundancy. In this way, you may remove any of the two power supplies without turning off the system.

Redundancy

During operation, both power supplies are switched on and share the current load. In case that one of them should fail, the other will instantaneously take 100% of the load without any loss. Similarly, if one power supply is removed from servicing, it can be switched off and removed while the chassis continues functioning.

Protection System

The power of each converter bay comes from the two shared power supplies. Each bay is isolated from each other under a certain protection mechanism, so that it is free from any problem that might occur to the power supplies or faulty converter bay. This is the best solution to protect your investment in media converters.

C ONNECTING TO POWER

The chassis system is equipped with two power supplies.

Step 1: Connect the supplied AC power cord to the receptacle on the front panel of each power supply.

Step 2: Attach the plug into a standard AC outlet with a voltage range from 100~240Vac.

User’s Guide 7

ClearCube F6151 Media Converter and Chassis System

Step 3: Turn on the chassis system by flipping the ON/OFF switch beside the receptacle to ON position. The LEDs on the front panel of the media converter chassis system will come on then.

Figure 3: The rear of the ClearCube F6151 Media Converter Chassis

System

Cooling System

The chassis system can hold two power supplies and up to sixteen media converters, and therefore, it is necessary to provide a good cooling system to obtain adequate ventilation.

The chassis is equipped with two hot-swappable power supplies with fans at the rear. The chassis is also equipped with one fan on the left and right side of the chassis.

Figure 4: The rear side of the ClearCube F6151 Media Converter Chassis

System

8 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Media Converter Overview

The media converter provides one channel for media conversion between 10/100BaseTX and 100BaseFX. Media converters are installed in a standard 19” chassis as shown below.

Product Overview

Product Features

• One-channel media conversion between 10/100BaseTX and

100BaseFX

• Fiber media allows multi-mode fiber using SC connector

• Auto negotiation of speed and duplex mode on TX port

• Auto MDIX on TX port

• One DIP switch for configuring link-fault-pass-through, fixed speed and half/full duplex

• Store-and-forward mechanism

• Non-blocking full wire-speed forwarding rate

• Support broadcast storm filtering

• Back-pressure & IEEE802.3x compliant flow control

• Front panel status LEDs

• External AC to DC power adapter

• Hot-swappable when used with a chassis

User’s Guide 9

ClearCube F6151 Media Converter and Chassis System

One-Channel Media Converter

Ports

The Converter provides one TX port and one FX port. For the FX port, it provides options of multi-mode fiber using an SC connector.

For the TX port, it uses RJ-45 connector, auto-MDIX, and auto senses the speed of 10/100Mbps and full/half duplex.

Port Settings

Port settings are made very simple by means of a DIP (Dual Inline

Package) switch at the rear panel of the module.

6

1 2 3 4 5

DIP SWITCH

There are six pins on the DIP switch for port settings. Refer to the table below for more details.

DIP switch

No.

Down (Default Setting)

1 Enable through link-fault-pass-

2 Enable auto negotiation for

TX port

3

4

Up

Disable link-fault-passthrough

Enable forced mode for TX port

TX port forced to 100Mbps TX port forced to 10Mbps

TX port forced to full duplex mode

TX port forced to half duplex mode

5 FX port forced to full duplex mode

6

FX port forced to half duplex mode

10 User’s Guide

ClearCube F6151 Media Converter and Chassis System

• First, disconnect the converter from the power. Then toggle

Pin 2 of the DIP switch to the up position to enable the forced mode for TX port.

NOTE Pin 2 must be toggled up prior to speed and duplex mode settings manually.

• Toggle down Pin 3 to force the TX port at the speed of

100Mbps. Or toggle up Pin 3 for 10Mbps speed.

• Toggle down Pin 4 to force the TX port at full duplex mode.

Or toggle up Pin 4 for half duplex mode.

• Toggle down Pin 5 to force the FX port at full duplex mode.

Or toggle up Pin 5 for half duplex mode.

• Connect the converter to the power again. The new setting will come into effect then.

Front Panel & LEDs

LED I NDICATORS

The LED indicators give you instant feedback on status of the converter:

LEDs State Indication

PWR on

PWR stands for POWER

100 (Mbps)

LNK/ACT

Steady Connection at the speed of

100Mbps

Off

Steady

Connection at the speed of 10Mbps

A valid network connection established

LNK stands for LINK

Flashing Transmitting or receiving data

ACT stands for ACTIVITY

User’s Guide 11

ClearCube F6151 Media Converter and Chassis System

FDX/COL

Off Neither valid network connection established nor transmitting/receiving data.

Steady Connection in full duplex mode

FDX stands for FULL-DUPLEX occurred

COL stands for COLLISION

Off Connection in half-duplex mode

12 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Specifications

C HASSIS S YSTEM

Capacity

Power

Cooling

LED Indicators

Dimensions

Net Weight

Sixteen bays for housing up to sixteen media converters

Tow power supplies provided, hotswappable

Two power supplies with fans

One fan on the left and right side of the chassis

2 LEDs (1 LED for each power supply’s power status)

W440 mm × D276 mm × H90 mm

Standard 19” size, 2 U

8.5kg approx. (Fully fitted with sixteen media converters)

P OWER S UPPLY

Power Input

Power Output

Load

Operating

Temperature

Storage

Temperature

Emissions

110~240Vac, 50~60Hz

12Vdc, 84W (x2) max.

7A (x2) max.

0°C to 40° C (32°F to 104°F)

-25°C to 70°C (-13°F to 158°F)

CE Class A, FCC part 15 Class A

M EDIA C ONVERTER

Applicable

Standards

Fixed Ports

Speed

10BaseT

100BaseTX/FX

Switching

Method

IEEE 802.3 10BaseT

IEEE 802.3u 100BaseTX & 100BaseFX

1 TX port, 1 FX port

10/20Mbps for half/full-duplex

100/200Mbps for half/full-duplex

Store-and-Forward

User’s Guide 13

ClearCube F6151 Media Converter and Chassis System

Forwarding rate 14,880/148,800pps for 10/100Mbps

LED Indicators Per Unit- (2 LEDs): Power; 100(Mbps)

Dimensions

Weight

Power

Power

Per Port- (2 LEDs): LNK/ACT; FDX/COL

L110 × W81 (max.) × H23 mm

190 g

External power adaptor 12VDC, 0.8A

7W Max.

Consumption

Operating

Temperature

Storage

Temperature

0°C ~ 40°C (32°F ~ 104°F)

-25°C ~ 70°C (-13°F ~ 158°F)

Humidity

Emissions

10 ~ 90%, non-condensing

FCC part 15 Class A, CE Mark

14 User’s Guide

ClearCube F6151 Media Converter and Chassis System

Support

Email:

Web site: [email protected]

support.clearcube.com

User’s Guide 15

ClearCube Technology, Inc.

8834 Capital of Texas Highway North Austin, Texas 78759 (512) 652-3500 www.clearcube.com

P/N G0400031 Rev A