Secure XINS2318-1 Installation and Operation Instructions

Add to My manuals
12 Pages

advertisement

Secure XINS2318-1 Installation and Operation Instructions | Manualzz
Installation and Operation Instructions
ELECTRIC FIREPLACE
XINS2318-1
Important Safety Instructions
Listing Approvals
3-4
5
Operating Instructions
6
Control Buttons/FunctionS
7
Remote Control
8
Maintenance
9
Troubleshooting
10
Installation
11
Inserting firebox
12
CONSUMER SAFETY INFORMATION
Read this manual before installing and operating this appliance.
Failure to follow these instructions may result in electric shock, fire property
damage, personal injury and will void the warranty.
Requires the use of Fireplace Mantel.
Do not store or use gasoline or other flammable liquids or vapors in the vicinity
of this appliance.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances,basic precautions should always be followed to reduce
the risk of fire,electric shock and injury to persons including the following:
1. The manufacturers instructions completely before using this appliance.
2. This appliance will become not when in use.To avoid burns,do not let bare skin touch
hot surfaces.The grill at the top of this heater in particular will become hot when the heater
is active. Keep combustible materials such as furniture, pillows, bedding,paper, cloth,
curtains, ect. at least 3 feet(0.9meter) away from the front of the appliance.Keep all items
away from the sides and back of the appliance and take special care not to block the air
intake or exhaust vents.
3. Extreme caution is necessary when the appliance is used by or near children or invalids
and whenever the heater is left operating and unattended.
4. Do not operate the heater if the power cord or plug has been damaged or the heater
has been damaged or malfunctioned in any way.Take the appliance to an authorized
service facility for examination,electrical or mechanical adjustment or repair.
5. Do not use outdoors.
6. Do not use the appliance in bathrooms,laundry rooms or other similar indoor
locations where it may contact water.Never locate the appliance where it may fall into a
bathtub or other water container.
7. Do not run the power cord under carpeting.Do not cover the power cord with throw
rugs,runners,or similar floor coverings.Take care to position the cord away from high traffic
areas and such that it can't be tripped over.
8. To disconnect the appliance,turn all controls "OFF",and then remove the plug from the
electrical outlet.
9. The appliance comes equipped with a 3 prong-grounding plug.Do not attempt to cut the
grounding prong.Connect to properly grounded 120V outlets only.This appliance,when
installed,must be electrically grounded in accordance with local codes or,in the absence of
local codes,with the current .
10. Do not insert or allow foreign objects to enter any ventilation or exhaust openings as
this may cause an electric shock or fire,or damage the appliance.
11. To prevent a possible fire,do not block air intakes or exhausts in any manner.Do not
use on soft surfaces,like a bed,where openings may become blocked.
12. All electrical heaters have hot and arching or sparking parts inside.Do not use in areas
where gasoline,paint,or flammable liquids are used or stored or where the appliance will
be exposed to flammable vapors.
13. Avoid using the appliance with an extension cord.Extension cords may overheat and
cause a risk of fire. If an extension cord MUST be used,the cord must be No.16 AWG
minimum size and rated not less than 1875 Watts.The extension cord must be a 3-prong
cord with grounding type plug and cord connection and should not exceed 20'(6m) in
length.
14. When transporting or storing the heater,take care to keep both the unit and power cord
/plug dry, free from excessive vibration and away from heat sources.
15.Use the heater only as described in this manual. Any other use not recommended by
the manufacturer may cause fire,electric shock, or injury to persons.
16. Do not attempt to burn wood or other materials in this heater.
SAVE THESE INSTRUCTIONS
LISTING APPROVALS
This heater has been tested in accordance with the CSA Standards.
Model Number:
XINS2318-1
Description:
Electric Fireplace
Voltage:
120V AC, 60Hz
Watts:
MAX 1500W
Length:
Height:
23.0
5.0
Depth:
17.1
OPERATING INSTRUCTIONS
Read all instructions and warning prior to operating the appliance.
Ensure that all control are in the "OFF" position before plugging the appliance into a
properly grounded electrical outlet.
The main switch is located at the top left corner on the front(see Figure 1)
The main control buttons are located at the top right corner on the front(see Figure 1)
Control Buttons
Master Power Button
FIGURE 1
CARE AND CLEANING OR MAINTENANCE
Turn heater OFF and unplug from electrical outlet before any cleaning or maintenance is
p e r f or m e d .
Keep combustible materials,such as furniture,pillows,bedding,papers,clothing,and curtains
at least 3 feet away from fireplace.
Use a vacuum or duster to keep heat and vent area from dust and dirt.The exterior of the
fireplace should be cleaned with a damp cloth or duster.Do not use abrasive cleaners or
liquid sprays.
Warning: Any other servcing should be performed by an authorized service representative.
CONTROL BUTTONS/FUNCTIONS
1
Master Power Button
2
4
3
Control Buttons
LOCATION
The Master Power Button is located in the top left hand corner of the front insert. The
control buttons are located in the top right corner of the front of the insert.
1 DISPLAY WINDOWS
2
HEATER SETTINGS
This fireplace insert consists of a fan forced electric heater with two heater settings,800
W(L) or 1,500W(H). Press the temperature button once(the digital screen appears
‘L’),press the temperature button a second time(the digital screen appears ‘H’),press the
third time,the heater will be turned off,and the rules is 'L' -'H'-'Off'-and so on. After heater
settings( 'L' or 'H' ), it appears the available Fahrenheit degrees. Note: the fan may
continue to run for a short time after the heater is turned off. The fan will turn off
automatically.
3 TIMER
This electric fireplace is equipped with a timer ranging from 1 hour to 9 hours. Press the
timer button on the insert panel to desired time(the digital screen appears from ‘1H’ to
‘9H’ when settings, and so on). After settings, it appears the available Fahrenheit degrees.
4 POWER ON/OFF BUTTON
Keep the Master Power Button is on.Press the power button once(The digital screen
appears the environmental Fahrenheit temperature-Thermometer),and the flame will work at
highest flame( 5 classes flame).Press the power button once to turn all functions off.
REMOTE CONTROL
* Remote Control Requires Two AAA Batteries Included.
.
A master button is located on the top left hand side of the insert. This button must be
turned ‘On’ to operate remote control. Turn button to ‘Off’ to disable the use of the remote
control.
1.Press the power button once(The digital screen appears the
environmental Fahrenheit temperature-Thermometer),
.
2. This fireplace insert consists of a fan forced electric heater
with two heater settings,800 watts or 1,500 watts. Press the
temperature button once(the digital screen appears ‘L’),press the
temperature button a second time(the digital screen appears
‘H’),press the third time,the heater will be turned off,and the
rules is 'L' -'H'-'Off'-and so on. After heater settings( 'L' or 'H' ), it
appears the available Fahrenheit degrees.
3. This electric fireplace is equipped with a timer ranging from 1
hour to 9 hours. Press the timer button on the remote control to
desired timer(the digital screen appears from ‘1H’ to ‘9H’ when
settings, and so on). After settings, it appears the available
Fahrenheit degrees.
Light bulbs may become loose during shipping. If the simulated flame effect is dim or does
not operate properly at first, please ensure that the light bulbs are properly secured in the
sockets(bulbs should be finger tight-do not over tighten). See “Replacing Light Bulb”
section of this manual for instructions.
MAINTENANCE
WARNING: Before attempting to perform any maintenance on this appliance, turn all controls
1 minutes
to the "OFF" position and the unplug. Allow
llow the appliance to be "OFF" for at least 10
before performing any maintenance in order to allow all components to cool properly.
Flame effect/Light bulb replacement:
Allow the electric fireplace insert to cool before attempting to replace light bulbs. The
flame effect on this electric fireplace insert is created by illuminating(2) clear 120V,25watt
E-12(small base, chandelier candle type)light bulbs. The life of the light bulbs will depend
on how often the fireplace is used. Do not use light bulbs that exceed 25 watts per bulb.
1.
2.
3.
4.
Turn power to off and unplug insert from electrical outlet before changing light bulbs.
Slide fireplace mantel away from wall to gain access to back of fireplace.
Locate access panel on back of insert.
Using a Phillips screwdriver, remove screws in access panel. Open door and replace
light bulbs as necessary. It is recommended that both bulbs be replaced at the same
time.
5. Follow steps 1 through 4 in reverse order to reinstall access panel.
NOTE: We do not supply replacement light bulbs. They can be purchased at many
home centers or hardware stores.
Care and maintenance:
Turn heater OFF and unplug from electrical outlet before any cleaning or maintenance is
performed.
Keep combustible materials such as furniture,pillows,bedding,papers,clothing,and
curtains at least 3 feet(0.9meter) away from fireplace.
Use a vacuum or duster to keep heat and vent area clean from dust and dirt. The exterior
of the fireplace should be cleaned with a damp cloth or duster. Do not use abrasive
cleaners or liquid sprays.
Warnings and cautions:
WARNING To avoid electrical shock not open the back panel of the insert unless the
power has been turned off, and the insert has been unplugged.
WARNING Any electrical repairs to this electric fireplace, should only be performed by a
qualified technician.
WARNING Any electrical wiring repairs should only be performed by qualified electrician,
and also must comply with local building codes.
WARNING Discontinue use of this electric fireplace if any of the follow has occurred:
Water damage, if insert has been dropped or dented, if power cord has become broken, if
power cord becomes hot to touch, if unit smokes or smells like smoke.
Note: When the heat function is used for the first time, a slight odor may be present. This
is normal and should not occur again unless heater is not used for extended periods of
time and dust is allowed to accumulate on heater element.
TROUBLESHOOTING
WARNING: Turn off the appliance, unplug and let cool for at least 10 minutes before
attempting to service. Only a qualified professional should attempt
mpt to service or repair the
appliance.
PROBLEM
POSSIBLE CAUSE
CORRCTIVE ACTION
1.No power, no indicator lights
Insert was not plugged in
Make sure that power cord is plugged
into 120V outlet
2.No power, no indicator lights
No power at outlet
Check circuit breaker or fuse
3.Power indicator lights come on, Broken or burned out light Follow instructions for replacing light
logs will not glow and no flame effect bulbs
bulbs
4.Log glow, but no flame
Flame spinner disconnected
Call customer service for instructions
5.Flame and logs glow, but no heat
Heater switch is off
Push heater button. Indicator light will
come on
6.Heater and /or flame turn off while Timer function may been on
operating
Push On/Off button to reset
INSTALLATION
PLANNING INSTALLATION
To avoid scratching the finish, assemble the product on a soft,non-abrasive surface,such as carpet or cardboard.
Assembly of this product may require more than one person.
TOOLS REQUIRED
Safety Goggles
Phillips screwdriver
HARWARE INCLUDED
Note: Hardware not shown to actual size.
AA
BB
PART
DESCRIPTION
QUANTITY
AA
Trim Pieces
3
BB
Small Screws
11
PART
DESCRIPTION
QUANTITY
A
Fireplace Insert
1
B
Remote Control
1
PACKAGE CONTENTS
Assembly (continued)
I
□
x3
Attach the metal brackets(S) to all three
sides of the firebox and two sides of the
mantel to ensure that your firebox does
not move around as you use it. all three
trims attach to the firebox by inserting and
tightening two screws(PP). both the left and right
side trim attach to the mantel front by inserting and t
ightening two screws(PP) one spare screw is included
□
Insert the firebox insert(P) into the mantel from
the rear. be very careful not to scratch the base(B)
□
Viewing from the front of the mantel, ensure that the
firebox insert(P) is in the center of the opening
PP
S

advertisement

Related manuals

advertisement